1 Meeting your Electrical Safety Testing & Quality Requirements Vincent Crabtree PhD Project Manager/Regulatory Advisor StarFish Medical 1 of 23
2 Contents 1. What are Standards and 60601? 2. Gap Analysis for Testing for Older Devices vs New Products 4. Similarities Between Reliability & Regulatory testing 2 of 23
3 Intent of Consensus Standards Standards Don t Just Apply to Medical Devices Compliance Demonstrates Safety Performance Standards Demonstrate Effectiveness Some (not all) are recognized by FDA Alternatively, FDA has own Guidance Documents, which are usually complimentary Some standards are very prescriptive & Compliance can be demonstrated via testing Others are more concerned about development Process & compliance must be demonstrated by documentation (DHF/Technical File) 3 of 23
4 Key Standards Important Standards for Medical Device Development ISO14971: Risk Management for Medical Devices IEC60601: A Series of Medical Electrical Equipment Standards: : General requirements for Basic Safety & Essential Performance. All electrical Medical Devices must comply : Requirements for Home Healthcare Medical Devices Plus many others Software Life Cycle Process IEC62304: Medical device software Software life cycle FDA ucm Guidance for the Content of Premarket Submissions for Software Contained in Medical Devices IEC62366: Application of Usability Engineering to Medical Devices ISO10993: Biological evaluation of Medical Devices Particularly Relevant for applied parts to a patient, but also Operators 4 of 23
5 History of IEC60601 Published by International Electrotechnical Commission 1 st Ed published 1977 as IEC601-1: Medical Electrical Equipment Introduced Creepage and Clearance for Patient and Operator Maximum temperatures Introduced leakage currents 2 nd Ed published 1988: Medical Electrical Equipment Part1: General Requirements for Safety Introduced 3 approaches to safety: insulation, protective earthing & protective impedance, and required at least 2 Means of Protection (MoP) Single fault protection Allowed to fail safe 3 rd Ed published 2005: Medical electrical equipment Part 1: General requirements for basic safety and essential performance Requires Essential performance to be defined and maintained (Functional safety, not fail safe) Requires Risk Management according to ISO14971 Introduces Operator & Patient Means of Protection Requires Usability process to IEC , similar to IEC62366 Requires Alarms to conform to IEC Requires PEMS (Software) to be designed using a Life Cycle process, such as IEC of 23
6 IEC60601 Structure IEC60601 Represents a family of standards General Standard (Part 1) IEC General Reqs. For EMC IEC Collateral Standards General Requirements Usability Eng. Process IEC Reqs. For Home Healthcare IEC Collateral IEC XX IEC Particular Reqs. For Electron Accelerators IEC Particular Reqs. For HF Surgical Equipment IEC IEC Particular Reqs. For Hearing Instruments Particular Reqs. For Automated Sphygmomanometers Part 2 Standards Particular Requirements ISO Particular Reqs. For Pulse Oximeters 6 of 23 Note: List is far from Exhaustive
7 IEC vs AAMI/ANSI ES FDA No longer recognizes IEC Ed 2, never recognized Ed 3 FDA only recognizes AAMI/ANSI ES Ed. 3 (Recognition #5-77) Existing equipment Grandfathered by FDA (Dec 31, 2013 cutoff) But, any change requiring new regulatory submission must conform to 3 rd Ed 3 rd Ed mandatory for all Products in EU - Even previously marketed Minor Differences Between Clauses, e.g. Includes ANSI standards in addition to IEC & ISO Supply voltage differences Minor variations in leakage currents Specific wiring codes for permanently installed equipment Differences in colours for medical gases Hospital grade connections Test house can simultaneously test to both IEC & ANSI/AAMI Note: OSHA only recently accepted 3 rd edition of 23
8 IEC Edition 3 Overview General Requirements Requires Risk Management process in-line with ISO14971 Requirements for Programmable Electrical Medical Systems (PEMS) Defines notion of Essential Performance Defines air clearance required between conductors Defines creepage (distance over an insulator) required between conductors Defines insulation requirements for different devices types i.e. mains able to withstand 5,000V RMS for 1 minute without harming patient Defines mechanical requirements for safety i.e. strength, impact, drop test etc Environmental testing (Humidity, Temperature, Altitude) Thermal & Radiation Limits Labelling Requirements Defines required labels applied to device Defines requirements for Instruction for Use (IFU) Compliance evaluated by Accredited Test House & DHF inspection 8 of 23
9 ISO14971 Application of Risk Management to Medical Devices Why Risk Management? All Regulatory bodies require Devices to be Safe & Effective Risk Management identifies & mitigates the Hazards & Risk of harm associated with the Device, in use or otherwise ISO14971 defines process requirements for risk management system in Medical Device design and development Risk Management Procedure defines risk management process that is followed during design Mandated by ISO13485 Health Canada, amongst others European Medical Device Directive (EN 2012) , IEC62366, IEC of 23
10 Risk Management File New for , mandatory for Europe CE Mark Risk Management Plan (can include as part of the Design Plan) Activities to reduce risk & demonstrate risk has been reduced Hazard Identification formally document applicable Hazards Risk Analysis Quantify Risk of Harm to Patient or Operator Mitigations & Verification of Safety features Assessments of Residual Risks in a Summary Report Process must be traceable Hazard identification -> Risk Analysis line items -> Detailed Specifications for any required mitigations -> Mitigation Verification -> Risk management Report 10 of 23
11 Hazard Identification Thorough Review to Identify Applicable Hazards Review Safety Databases for Similar Products FDA MAUDE, Medical & Radiation Emitting Device Recalls MHRA SwissMedic Usability Hazards: Intended Use & Foreseeable Misuse Hence Workflow & Usability as defined in IEC62366 Review, Define & Document Applicable Hazards clauses in & Particulars that refer to the RMF Classes of Hazards in ISO14971 Table E.1 Classify software per IEC62304 Classify software per FDA guidance 11 of 23
12 Risk Analysis Documenting Process is the key Identify appropriate Hazards Evaluate whether Risk Reduction is necessary Probability Severity Detectability (optional, but good for finer grading) Define Mitigations & re-evaluate the Risk Evaluate whether the mitigation has introduced new risks Justify any residual risks in the Risk Management Report Justify the combination of residual risks in the Risk Management Report 12 of 23
13 IEC62366 Application of Usability Engineering to Medical Devices User Error is a Design Flaw Use error is preferred term Describes a Usability Engineering Process Usability Engineering process intended to achieve reasonable usability, reducing use errors and associated risks Calls on ISO14971 risk assessment Usability Engineering Plan part of Part of Design Plan Identify Use Scenarios with Stakeholder Focus Groups (Documented) Frequently Used functions, Foreseeable Misuse & Routine Violations Usability relating to markings and labeling (includes IFU) Assess Usability in Risk Management Develop Usability specifications & Validation Plan Usability Validation Activity Actors/Users/Clinicians Usability Validation Report 13 of 23
14 Use Error Examples Pat Buchanan received many more votes than expected Device Use Error Root Cause IV Pump Fluid Tube pinched by Hinged cover User must pull tube away from door before closing Dialysis Machine User closed red clamp instead of Green Red/Green colour blindness common in Men Heart Assist Pump User Permanently Disabled Alarms instead of Temporary Silence Symbols indicating Alarm off vs Alarm Suspended confusing Insulin Pump User Set 7pm instead of 7am Display is small, target user was elderly, 24hr clock not common in N America 14 of 23
15 IEC62304 Medical Device Software Software Life Cycle process Defines the Design & Development Process for Medical Device Software Requires Software Risk Analysis according to ISO14971: assumes 100% probability of software to behave as specified Software that controls features which could cause harm preferably mitigated in Hardware otherwise partitioned systems, extensive Unit verification Summary Software Development Process Software Development Planning Software Risk Analysis, Requirements, traceability, change control, verification planning, documentation & others Develop Software Requirements & Usability Requirements Transform software requirements into Software Architecture For Medium/High Risk software, decompose architecture into Items & Units Classify Software Units with a Safety Class according to Risk Code/Implement units, Code review, iterate as required, documenting as you go High Risk software requires Software Units to be individually Verified Verify Integrated Software Evaluate residual anomalies for risk, repeat if risks not acceptable, else Release Validate Software System 15 of 23
16 2 nd Edition Gap Analysis For A Well documented, recent DHF this can be an Effective Solution TR62348 (2006) Mapping between the clauses of the 3 rd Edition of IEC and the 1988 Edition as amended Free download from (withdrawn), ~100 pages (English) 1:1 mapping with equivalent/new clauses Practically speaking, requires one to keep in mind all 3 documents Good solution for: May need updates for Usability/Essential Performance Electromechanical device, or with noncritical software You have already: Requirements, Risk Analysis, Specs, Verification & Validation documentation Particular Problem for Software How to demonstrate software lifecycle process was followed after the fact? 16 of 23
17 Legacy Products & Older products, Less well documented DHF Review Existing DHF Bottom Up documentation strategy Review Mechanical Drawings for compliance Safety Factors (Sec 9.8) Requires 2.5+ for ductile or 4+ for brittle parts (Depending on knowledge) Either update drawings, remanufacture parts with improved safety factors Alternatively risk analysis line item which evaluates risk of using 2x safety factor & justifies with historical data e.g. 10,000 units in the field for 20 years Review Electrical schematics and assembly drawings for compliance MOPP/MOOP: Creepage, clearance, solid insulation etc May need to up-rev & modify design e.g. transformers, plastic covers (reinforced) Alternatively risk analysis line item evaluate risk of harm and justify safe with historical data. May be more difficult to justify due to prescriptive standard (current) Review Failure Modes Fail safe: particular standard states essential performance What to do if not compliant? Gotchas: Mechanical strength, vibration, shock rough handling, steps, lips, push, impact 17 of 23
18 Legacy Products Software & Demonstrating Software Life Cycle for 10 year old Binaries Typical problems: Worst case: Assembly Source & Ancient Binaries Original Programmer has left the building Mixed Requirements, design rationale, specs, no design reviews Poorly structured software make it work rather than designed Obsolete tools makes it difficult to recreate same binary Solutions Decompose existing software Takes a long time 100hrs to develop flowcharts for a 3x CPU system Instrument software for debug/verification information not always possible (e.g. no comms.) Develop Software Requirement, Specs, perform code design reviews May identify safety issues Either solve with additional hardware or risk analysis line item Verify and Validate software: Include Software Usability if GUI Alternatives: Start Again Forward design process Requirements, Architecture, Risk analysis, specs, verification Could use Same processor obsolescence & tools issue Different processor: plug in CPU module, PCB board revision 18 of 23
19 New Product Development & E d. 3 Compliance Designed in from the Outset Design Plan Describes appropriate Standards (e.g. Part 1, Part 1-2, Part 1-11) Design Plan describes documentation Hierarchy 80601/ xx Particular Standards for Basic Safety and Essential Performance Risk Management Plan describes risk management process Develop Product Requirements Develop System Architecture compatible with E.g. Low voltage external certified PSU provides 1 means of protection E.g. 15W or less power source removes some requirements Perform Preliminary Hazard Identification Perform Risk Analysis Engagement to Quantify Risk of Harm Modify Architecture, develop specs Verify, Validate (Usability and Software) 19 of 23
20 Reliability Testing Reliability Testing required for Compliance General standard has shock/impact/vibration requirements (15.3) Push Test Impact Test Drop test Rough Handling (Ascending/Descending steps, ledges, door frames) Particular standard may have additional requirements e.g.: IEC Home Healthcare Environment Section : Peak Acceleration, broad-band vibration, fall height ISO Pulse Oximetry equipment Section : Peak Acceleration, broad-band vibration, fall height 20 of 23
21 Conclusions E d. 3 Required Documentation is Majority of DHF A typical Submission, the following documents are required Risk Management File (Section 4.2) Shall includes at least: Risk Management Plan Hazard Identification Risk Analysis Risk Management Report PEMS Lifecycle File (Clause 14) forms part of Risk Management, typically requires: Software Requirements Software Architecture Software Risk Assessment Software Specification (with sub-systems verification as required) Software Verification Plan & Report Software Validation Plan & Report referring to Basic Safety and Essential performance Usability File (Section 12.2) Usability Requirements may form part of Product Requirements Use error, foreseeable misuse & Routine violations in Risk Assessment Usability Validation Plan & Report Particular standards (e.g.home Use) may require Validation of Labeling (particularly IFU) 21 of 23
22 Suggestions Ways to make your life easier (potentially) Read the Standard(s)! Obtain Test house Checklist has a lot to say on mechanical design If you cant meet these, either redesign or risk analysis Legacy Devices Gap analysis may be simplest for Electromechanical device with recent DHF For complex software e.g. software controlling safety or performance: Carefully assess the amount of effort required to retroactively generate DHF Sometimes starting Software Development again is quicker and less expensive It may not be possible to mitigate existing risks (particularly software) Preferentially implement hardware risk mitigation Alternatively include Risk Analysis lines with historical data New Product Development Follow conventional Watefall/V model Mitigate risk by system architecture Safe by Design Software not controlling critical aspects for safety or performance 22 of 23
23 Questions? Additional Materials at StarFish Medical - ISO14971 Webinar - FDA Risk Management - FDA Use Errors - FDA Guidance for Software Contained in Medical Devices - US FDA Maude website: US Recall website MHRA Recall website SwissMedic website: 23 of 23
24 About the speaker Vincent Crabtree is a Project Manager and Regulatory Advisor, with an emphasis on Project Leadership ensuring projects conform to consensus standards such as ISO14971, IEC and managing clients setting-up Quality Management Systems that comply with ISO13485 and FDA Quality System Regulations. He is passionate about commercializing innovative technology, and brings an entrepreneurial perspective. Vincent has a Diploma and Bachelor s Degree in Electrical Engineering, and a PhD in Optical Biomedical Engineering with over 20 years of experience in Electronics development, 17 years in Healthcare technology R&D and 10 years in medical device development and commercialization. StarFish Medical is a Medical Device Design company with a full complement of design, development, and manufacturing services. We use the PathFinder process to reduce wasted effort and increase success for medical device product definition, technical engineering, and product development. Prototype and volume production are delivered in an ISO certified Quality Management System and FDA registered manufacturing and clean room facility. 24 of 23
The New Paradigm for Medical Device Safety. Addressing the Requirements of IEC 60601-1 Edition 3.1
The New Paradigm for Medical Device Safety Addressing the Requirements of IEC 60601-1 Edition 3.1 Medical devices play a vital role in the diagnosis and treatment of most health-related conditions, and
How To Write Software
1 Medical Device Software - Software Life Cycle Processes IEC 62304 2 Credits John F. Murray Software Compliance Expert U.S. Food and Drug Administration Marcie R. Williams Medical Device Fellow Ph.D.
WHITEPAPER: SOFTWARE APPS AS MEDICAL DEVICES THE REGULATORY LANDSCAPE
WHITEPAPER: SOFTWARE APPS AS MEDICAL DEVICES THE REGULATORY LANDSCAPE White paper produced by Maetrics For more information, please contact global sales +1 610 458 9312 +1 877 623 8742 [email protected]
IeC 60601-1 Medical Design Standards-3 rd Edition
IeC 60601-1 Medical Design Standards-3 rd Edition standards are an integral part of product design and development, and are clearly important in medical applications. however, there is an additional aspect
Software-based medical devices from defibrillators
C O V E R F E A T U R E Coping with Defective Software in Medical Devices Steven R. Rakitin Software Quality Consulting Inc. Embedding defective software in medical devices increases safety risks. Given
Risk Assessment for Medical Devices. Linda Braddon, Ph.D. Bring your medical device to market faster 1
Risk Assessment for Medical Devices Linda Braddon, Ph.D. Bring your medical device to market faster 1 My Perspective Work with start up medical device companies Goal: Making great ideas into profitable
Medical Device Software Standards for Safety and Regulatory Compliance
Medical Device Software Standards for Safety and Regulatory Compliance Sherman Eagles +1 612-865-0107 [email protected] www.softwarecpr.com Assuring safe software SAFE All hazards have been addressed
Risk Management in IEC 60601-1 3 rd Edition. Presented by Alberto Paduanelli Medical Devices Lead Auditor, MHS-UK, TÜV SÜD Product Service
Risk Management in IEC 60601-1 3 rd Edition Presented by Alberto Paduanelli Medical Devices Lead Auditor, MHS-UK, TÜV SÜD Product Service General Information Time of presentation: 50-60 min. Questions
International standards and guidance that address Medical Device Software
International standards and guidance that address Medical Device Software Sherman Eagles Technical Fellow Medtronic CRDM Convener IEC 62A/ISO 210 JWG3 Co-convener IEC 62A/ISO 215 JWG7 Standards in the
Overview of International Medical Device Human Factors Standards. Ed Israelski PhD, Director of Human Factors Abbott Abbott Park, IL, USA
Overview of International Medical Device Human Factors Standards Ed Israelski PhD, Director of Human Factors Abbott Abbott Park, IL, USA Outline History of Medical Device Human Factors Standards Summary
IBM Rational systems and software solutions for the medical device industry
IBM Software August 2011 IBM Rational systems and software solutions for the medical device industry Improve processes, manage IEC 61508 and IEC 62304 standards, develop quality products Highlights Manage
FDA Perspectives on Human Factors in Device Development
FDA Perspectives on in Device Development Molly Follette Story, PhD FDA /CDRH / ODE Understanding Regulatory Requirements for Usability Testing RAPS Webinar June 7, 2012 Overview What are human factors
Introduction into IEC 62304 Software life cycle for medical devices
Introduction into IEC 62304 Software life cycle for medical devices Christoph Gerber 4. September 2008 SPIQ 9/5/2008 1 Agenda Current Picture Regulatory requirements for medical device software IEC 62304
2015. All rights reserved.
DOCUMENT: Future AAMI/IEC 62304:2006/AMD1, 18-August-2015 Final Draft International Standard for Vote, Amendment 1 to IEC 62304: Medical device software Software life cycle processes. Public Review Draft
The FDA Perspective on Human Factors in Medical Device Software Development
The FDA Perspective on in Medical Device Development Molly Follette Story, PhD FDA /CDRH / ODE 2012 IQPC Design for Medical Devices Europe Munich, Germany Februar y1, 2012 Overview Guidance for FDA premarket
codebeamer INTLAND SOFTWARE codebeamer Medical ALM Solution is built for IEC62304 compliance and provides a wealth of medical development knowledge
codebeamer Medical ALM Solution is built for INTLAND Traceability matrix Medical wiki Risk management IEC 62304 compliance codebeamer INTLAND codebeamer Medical ALM Solution is built for Medical Device
3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & 8 3. 4.0 Instructions For Installation, Operation & Maintenance
SPECIFICATION FOR LOW VOLTAGE SWITCHBOARD SEN I N D E X Description 10 STANDARD TECHNICAL REQUIREMENTS 11 Standards 12 General Operating Conditions 13 General Description Of Switchboard 131 Structure 132
Medical Software Development. International standards requirements and practice
Medical Software Development International standards requirements and practice Food and Drug Administration What? A public health agency Why? Protect American consumers How? By enforcing the Federal Food,
Regulatory expectations on user engagement for medical devices
Regulatory expectations on user engagement for medical devices World Usability Day 2014 - Enschede November 13 Sonja Paus-Buzink PhD Managing Human Factors Specialist Human Factors Engineering UL and the
Technical Update TAA.TU.11093 Rev. 1
http://www.gambro.com/en/usa_tech/ 800-525-2623 303-222-6500 Technical Update TAA.TU.11093 Rev. 1 Effective: 05 APR 2013 CO# 13084 Product: Subject: From: Phoenix Dialysis System Required Electrical Safety
Risk Analysis Fanless Slim Medical Panel PC, models xxxx-onyx-2121dtyxxxxxxx
Risk Analysis Fanless Slim Medical Panel PC, models xxxx-onyx-2121dtyxxxxxxx Company: Creation Date: 2013-08-22 Abbreviation: Project Number: Project : Version Number: Version : Life Cycle Phase: ONYX-2121DT
Major IEC 60601-1 3rd Ed. changes
Major IEC 60601-1 3rd Ed. changes Why 90% of Medical Products Do Not Comply Presented By: Michael Brousseau Engineering Team Leader Medical Devices Group [email protected] Tel: + 1 (978) 635-8670
White Paper Product Quality Fujitsu ESPRIMO PCs, Fujitsu CELSIUS workstations, Fujitsu FUTRO thin clients
White Paper Product Quality Fujitsu ESPRIMO PCs, Fujitsu CELSIUS workstations, Fujitsu FUTRO thin clients Quality from beginning to end is the principle that guides Fujitsu from the design and planning
Overview of Medical Device Design Controls in the US. By Nandini Murthy, MS, RAC
Overview of Medical Device Controls in the US By Nandini Murthy, MS, RAC 18 controls are a regulatory requirement for medical devices. In the US, compliance with the design controls section of 21 Code
INTERNATIONAL STANDARD
INTERNATIONAL STANDARD IEC 61892-1 First edition 2001-12 Mobile and fixed offshore units Electrical installations Part 1: General requirements and conditions Unités fixes et mobiles en mer Installations
FAQs-Main switchboard design criteria
FAQs-Main switchboard design criteria Q: What is the Australian standard for main switchboards? Current Australian standard is AS/NZS 3439.1: 2002 originating from IEC 60439. The new series of standard
Trends in Machinery/ Automation Safety
Trends in Machinery/ Automation Safety by Roberta Nelson Shea Director, Safety & Compliance Symbotic LLC and C&S Wholesale Grocers 2013 SES - The Society for Standards Professionals Why Machinery Safety
Quality Risk Management - The Medical Device Experience. Niamh Nolan Principal Design Assurance Engineer Boston Scientific
Quality Risk Management - The Medical Device Experience Niamh Nolan Principal Design Assurance Engineer Boston Scientific Agenda Intent of Risk Management (RM) and Associated Regulations Overview of RM
1) Title: Senior R&D Engineer. Job Description
1) Title: Senior R&D Engineer Job Description Contributes as a team member on development projects carrying out assigned responsibilities in a timely, diligent, safe, and professional manner. May act as
Company Overview & Capabilities
Company Overview & Capabilities Company Overview Mission Statement "The Mission of is to provide expert technical resources to our partners in order to develop concise and timely strategic solutions based
How to Use the Design Process to Manage Risk: Elements of Design Controls and Why It Matters
environmental failure analysis & prevention health technology development How to Use the Design Process to Manage Risk: Elements of Design Controls and Why It Matters Kevin L. Ong, Ph.D., P.E. Managing
Cross-beam scanning system to detect slim objects. 100 mm 3.937 in
891 Object Area Sensor General terms and conditions... F-17 Related Information Glossary of terms... P.1359~ Sensor selection guide...p.831~ General precautions... P.1405 PHOTO PHOTO Conforming to EMC
EMOSAFE EN-100. Network Isolators for PCB assembly 1 GENERAL DESCRIPTION. Product Data Sheet ENGLISH
ENGLISH EMOSAFE EN-100 Product Data Sheet Network Isolators for PCB assembly November 2013 1 GENERAL DESCRIPTION The EMOSAFE EN-100 Network Isolator interrupts all galvanically conducting connections (conductors
30 In Compliance October 2014 www.incompliancemag.com
30 In Compliance October 2014 www.incompliancemag.com Medical Devices in a Wireless World BY IVAYLO TANKOV While wireless technology is now an integral component of a wide variety of manufactured products,
Medical Devices : Guide to defining a test strategy
Medical Devices : Guide to defining a test strategy November 2014 Copyright 2015 LNE - www.lne. 1 This guide is a document intended to support medical device manufacturers/importers as they plan the preclinical
Explosion proof enclosures
1 of 7 Explosion proof enclosures DE8 C 2 of 7 The Ex d enclosures are rugged and designed for harsh environment like: Oil and gas industry Chemical industry Pharmaceutical industry Agribusiness Without
CONSOLIDATED VERSION IEC 62304. Medical device software Software life cycle processes. colour inside. Edition 1.1 2015-06
IEC 62304 CONSOLIDATED VERSION Edition 1.1 2015-06 colour inside Medical device software life cycle processes INTERNATIONAL ELECTROTECHNICAL COMMISSION ICS 11.040 ISBN 978-2-8322-2765-7 Warning! Make sure
SECTION 1: REQUIREMENTS FOR CERTIFICATES OF COMPLIANCE FOR CLASSES OF RADIATION APPARATUS
Department of Health and Human Services Population Health Radiation Protection Act 2005 Section 17 CERTIFICATE OF COMPLIANCE: STANDARD FOR RADIATION APPARATUS - X-RAY MEDICAL DIAGNOSTIC (BIOPSY) SECTION
Medical Device Training Program 2015
Medical Device Training Introduction Supplementary training and education is often overlooked by medical device professionals until it is triggered by an upcoming FDA or Notified Body and/or ISO 13485
Medical Device Software Do You Understand How Software is Regulated?
Medical Device Software Do You Understand How Software is Regulated? By Gregory Martin Agenda Relevant directives, standards, and guidance documents recommended to develop, maintain, and validate medical
SECTION 1: REQUIREMENTS FOR CERTIFICATES OF COMPLIANCE FOR CLASSES OF RADIATION APPARATUS
Department of Health and Human Services Population Health Radiation Protection Act 2005 Section 17 CERTIFICATE OF COMPLIANCE: STANDARD FOR RADIATION APPARATUS - X-RAY MEDICAL DIAGNOSTIC (MOBILE RADIOGRAPHY)
Product Safety Considerations for Insulation Coordination of Low- Voltage Equipment. Scott Aldous, Compliance Engineer
Product Safety Considerations for Insulation Coordination of Low- Voltage Equipment Scott Aldous, Compliance Engineer What is Insulation Coordination? From IEC 60664-1, Edition 1.2: So what does that mean
functional Safety UL Functional Safety Mark
functional Safety UL Functional Safety Mark Program UL Functional Safety Mark Program With the advent and evolution of functional safety standards in North America and Europe, UL is now offering a UL Functional
RISK MANAGEMENT IN 61010-1, THIRD EDITION
RISK MANAGEMENT IN 61010-1, THIRD EDITION Learn about the changes and compliance requirements in IEC 61010-1 3rd Edition Intertek 545 E. Algonquin Rd. Arlington Heights, IL 60005 www.intertek.com 1-800-WORLDLAB
Guidance for upgrading to GB4943.1-2011 (IEC 60950-1: 2005, MOD)
Guidance for upgrading to GB4943.1-2011 (IEC 60950-1: 2005, MOD) Note: This guidance document is a translation of official Chinese document which is issued by CQC (China Quality Certification Center) on
The table below lists the symbols used on the Clamp and/or in this manual. Important Information. See manual.
i800 AC Current Clamp Instruction Sheet Introduction The i800 AC Current Clamp, the Clamp, has been designed for use with multimeters, recorders, power analyzers, safety testers, etc., for accurate non-intrusive
Model Based Engineering and Its Integration with Safety Assurance Cases for Medical Device Software
Model Based Engineering and Its Integration with Safety Assurance Cases for Medical Device Software Yi Zhang Ph.D., Paul Jones Office of Science and Engineering Laboratories Center for Devices and Radiological
DEDICATED TO EMBEDDED SOLUTIONS
DEDICATED TO EMBEDDED SOLUTIONS RELIABILITY IN SUBSEA ELECTRONICS TECHNIQUES TO OBTAIN HIGH RELIABILITY STIG-HELGE LARSEN KARSTEN KLEPPE DATA RESPONS 2012-10-16 AGENDA Introduction Analysis and Design
SURGE PROTECTIVE DEVICES
SURGE PROTECTIVE DEVICES 1. INTRODUCTION In order to ensure safety of people, protection of equipment and, to a certain extent, continuity of supply, insulation co-ordination aims at reducing the likelihood
NI 9423. NI C Series Overview DATASHEET. 8-Channel Sinking Digital Input Module
DATASHEET NI 9423 8-Channel Sinking Digital Input Module 8-channel, 100 µs digital input 24 V logic, sinking digital input Compatible with NI CompactDAQ counters 250 Vrms, CAT II isolation 10-position
Information Security Policy. Document ID: 3809 Version: 1.0 Owner: Chief Security Officer, Security Services
Information Security Policy Document ID: 3809 Version: 1.0 Owner: Chief Security Officer, Security Services Contents 1 Purpose / Objective... 1 1.1 Information Security... 1 1.2 Purpose... 1 1.3 Objectives...
INTEL S SAFETY WARNING LABEL REQUIREMENTS
INTEL S SAFETY WARNING LABEL REQUIREMENTS INTRODUCTION: Direction is provided on Intel s Safety Warning Label requirements to ensure suppliers provide equipment with hazards identified and the safety precautions
FAMI-QS Certification Rules for Operators. Rules for Operators
Rules for Operators TABLE OF CONTENTS 1. Application for certification and FAMI QS associate membership...2 2. Assessment of operators...3 2.1. Audit planning...3 2.2. Frequency of audits and re certification...5
LV MCC LOW VOLTAGE SWITCHGEAR MOTOR CONTROL CENTRE PRODUCT GUIDE
LV MCC LOW VOLTAGE SWITCHGEAR MOTOR CONTROL CENTRE PRODUCT GUIDE 380/415/690 Volt AC 50/65/80/100 ka 1. Product Guide Low Voltage Motor Control Centre CONTSTRUCTION Continuous "poured in place" gasket
Software Development for Medical Devices
Overcoming the Challenges of Compliance, Quality and Cost An MKS White Paper Introduction Software is fast becoming the differentiator for manufacturers of medical devices. The rewards available from software
USB-to-Data Highway Plus Cable
Installation Instructions USB-to-Data Highway Plus Cable Catalog Number 1784-U2DHP Topic Page Important User Information 2 Environment and Enclosure 3 Install the Cable 5 Configure the DH+ Node Address
Wiser Panel Meter, Model Number WISERCTPM200 Installer s Guide
Instruction Bulletin EAV85226 08/2014 Wiser Panel Meter, Model Number WISERCTPM200 Installer s Guide Retain for future use. Product Description Kit Contents The Wiser Panel Meter is for use in energy management
Medical Devices. Notified Bodies and the CE certification Process for Medical Devices. European Surgical Robotics Demonstration Day
Medical Devices Notified Bodies and the CE certification Process for Medical Devices European Surgical Robotics Demonstration Day 27 th March 2014, Leuven, Belgium 1 Bart Mersseman Product Manager Medical
Safe and Efficient Hydraulic Systems Review of ISO 4413 Hydraulic Fluid Power General Rules and Safety Requirements for Systems and Their Components
Safe and Efficient Hydraulic Systems Review of ISO 4413 Hydraulic Fluid Power General Rules and Safety Requirements for Systems and Their Components Jerry Carlin Eaton Hydraulics November 20, 2013 Evolution
How To Validate Software
General Principles of Software Validation; Final Guidance for Industry and FDA Staff Document issued on: January 11, 2002 This document supersedes the draft document, "General Principles of Software Validation,
IEC 60439 >>> IEC 61439 GUIDE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES
xl 3 configurable assemblies IEC 60439 >>> IEC 61439 GUIDE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES XL 3 configurable assemblies guide to migration from IEC 60439 to IEC 61439
TÜV UK Ltd Guidance & Self Evaluation Checklist
ISO 9001:2015 Revision TÜV UK Ltd Guidance & Self Evaluation Checklist Why ISO 9001 is changing All ISO management system standards are subject to a periodic review under the rules by which they are written.
Homologation Directive for TT04 Vehicle Tracking Systems
Homologation Directive for TT04 Vehicle Tracking Systems VERSION 3.0 (31 March 2014) - Requirements and testing methods for vehicle tracking systems Issued by the Insurance Bureau for Vehicle Crime (Stichting
IEC 61508 Overview Report
IEC 61508 Overview Report A Summary of the IEC 61508 Standard for Functional Safety of Electrical/Electronic/Programmable Electronic Safety-Related Systems exida Sellersville, PA 18960, USA +1-215-453-1720
Envisioning a Requirements Specification Template for Medical Device Software
Envisioning a Requirements Specification Template for Medical Device Software Hao Wang 1, Yihai Chen 2, Ridha Khedri 3, and Alan Wassyng 4 1 Faculty of Engineering and Natural Sciences, Aalesund University
USER MANUAL CHARGING STATIONS FOR ELECTRIC VEHICLES
USER MANUAL CHARGING STATIONS FOR ELECTRIC VEHICLES 204.CAxxx 204.CBxxx 204.UBxxx 204.WBxxx MP36289 1 ZP90856-GB-6 INDICE 1 SYSTEM DESCRIPTION... 4 1.1 MODES OF OPERATION... 4 2 USER INTERFACE... 6 2.1
Machinery Safety. Presented by Paul Laidler. TÜV SÜD Product Service
Machinery Safety Presented by Paul Laidler Machinery Division Safety Solutions Assistance in meeting the requirements of machinery safety legislation Machinery, Low Voltage and Electro Magnetic Compatibility
IEC 60601-1: Changes from 2nd to 3rd Edition
September 2008 Introduction The 3rd Edition of IEC 60601-1 represents a shift in philosophy from the 2nd Edition, including a greater emphasis on risk management and essential performance. As with any
i410/i1010 AC/DC Current Clamp
/i1010 AC/DC Current Clamp Instruction Sheet Safety Information XW Read First: Safety Information To ensure safe operation and service of the current clamp, follow these instructions: Read all operating
Medical Product Software Development and FDA Regulations Software Development Practices and FDA Compliance
Medical Product Development and FDA Regulations IEEE Orange County Computer Society March 27, 2006 Carl R. Wyrwa Medical Product Development and FDA Regulations Introduction Regulated FDA Overview Medical
Mobile Medical Application Development: FDA Regulation
Mobile Medical Application Development: FDA Regulation Mobile Medical Applications: Current Environment Currently over 100,000 mobile health related applications are available for download; there is an
Is your current safety system compliant to today's safety standard?
Is your current safety system compliant to today's safety standard? Abstract It is estimated that about 66% of the Programmable Electronic Systems (PES) running in the process industry were installed before
SUPPLIER QUALITY MANAGEMENT SYSTEM QUESTIONNAIRE
Company Name Street Address City, State, Zip code Phone Number Fax Company Website Email Address ORGANIZATION NAME PHONE NUMBER EMAIL ADDRESS President/CEO General Manager Engineering Manager Production
COMMITTEE ON STANDARDS AND TECHNICAL REGULATIONS (98/34 COMMITTEE)
EUROPEAN COMMISSION ENTERPRISE AND INDUSTRY DIRECTORATE-GENERAL Regulatory Policy Standardisation Brussels, 9 th November 2005 Doc.: 34/2005 Rev. 1 EN COMMITTEE ON STANDARDS AND TECHNICAL REGULATIONS (98/34
Effective Software Verification for Medical Devices
STERLINGTECH AND KLOCWORK WHITE PAPER NOVEMBER 2009 Effective Software Verification for Medical Devices Achieving compliance and meeting productivity goals with static analysis In addition to producing
Design Verification The Case for Verification, Not Validation
Overview: The FDA requires medical device companies to verify that all the design outputs meet the design inputs. The FDA also requires that the final medical device must be validated to the user needs.
Processor. Installation Guide
Processor Installation Guide Land Instruments International Dronfield, S18 1DJ England Telephone: (01246) 417691 Facsimile: (01246) 410585 Email: [email protected] Internet: www.landinst.com
Reduce Medical Device Compliance Costs with Best Practices. [email protected]
Reduce Medical Device Compliance Costs with Best Practices [email protected] 1 Agenda Medical Software Certification How new is Critical Software Certification? What do we need to do? What Best Practises
ISO 22000 Food Safety Management System
This is an ideal package for Food Manufacturers looking to meet International Food Safety Standards. This system meets the requirements of International Standard ISO 22000:2005 for Food Safety Management
Application Technique. Safety Function: Magnetic Door Switch Monitoring
Application Technique Safety Function: Magnetic Door Switch Monitoring Products: MC1 Magnetically-coded Door Switch, Guardmaster Dual-input Safety Relay Safety Rating: CAT. 3, PLd to EN ISO 13849-1: 2008
Intertek Research & Performance Testing Technical Report S64604 Issue 1 Page 1 of 17. Report issued by: S64604 Issue 1
Intertek Research & Performance Testing Technical Report S64604 Issue 1 Page 1 of 17 TECHNICAL REPORT Client: Stephen Curtler Electrical Safety Council 18 Buckingham Gate London SW1E 6LB Report issued
Medical Device Directive 2007/47/EC What is New? Are we moving towards Drug Rules?
Medical Device Directive 2007/47/EC What is New? Are we moving towards Drug Rules? CEMO Congress, Paris, February 3rd, 2011 Dr. Martine Dehlinger-Kremer Vice President Global Regulatory Affairs Agenda
Selecting Sensors for Safety Instrumented Systems per IEC 61511 (ISA 84.00.01 2004)
Selecting Sensors for Safety Instrumented Systems per IEC 61511 (ISA 84.00.01 2004) Dale Perry Worldwide Pressure Marketing Manager Emerson Process Management Rosemount Division Chanhassen, MN 55317 USA
Electrical Shore Connections / Cold Ironing
STANDARD FOR CERTIFICATION No. 2.25 Electrical Shore Connections / Cold Ironing JULY 2014 The electronic pdf version of this document found through http://www.dnv.com is the officially binding version
CompactLogix Power Supplies Specifications
Technical Data CompactLogix Power Supplies Specifications 1768 CompactLogix Power Supplies Catalog Numbers 1768-PA3, 1768-PB3 1769 Compact I/O Power Supplies Catalog Numbers 1769-PA2, 1769-PB2, 1769-PA4,
Medical Device Software
Medical Device Software Bakul Patel Senior Policy Advisor 1 Overview Medical devices and software Oversight principles and Current approach Trends, Challenges and opportunities Addressing challenges 2
Demystifying the European Machinery Directive and SEMI Requirements for the Industrial Automation and Semiconductor Markets
Demystifying the European Machinery Directive and SEMI Requirements for the Industrial Automation and Semiconductor Markets An Overview of Current Changes and Directions By Andras Szende Senior Engineer
Conventional Fire Detection and Extinguishant Control System Specification
Conventional Fire Detection and Extinguishant Control System Specification Page 1 of 9 Scope Furnish a complete 24VDC Conventional, electrically supervised, combined fire detection and extinguishant release
LightingEurope EU Compliant Requirements Products Sheets for LIGHTING COMPONENTS
LightingEurope EU Compliant Requirements Products Sheets for LIGHTING COMPONENTS 1 st Edition 29 th November 2013 Table of content a. Disclaimer... 3 b. Introduction... 3 c. Summary check lists for components...
Title: Basic Principles of Risk Management for Medical Device Design
Title: Basic Principles of Risk Management for Medical Device Design WHITE PAPER Author: Ganeshkumar Palanichamy Abstract Medical devices developed for human application are used for diagnostic or treatment
BS5839 Part 1:2002 Overview
BS5839 Part 1:2002 Overview 1 Contents Introduction So why is the current standard being revised? The brief for the new standard Changes to structure of current Standard Enhanced certification of Fire
ISO 14971: Overview of the standard
FDA Medical Device Industry Coalition ISO 14971: Overview of the standard Risk Management Through Product Life Cycle: An Educational Forum William A. Hyman Department of Biomedical Engineering Texas A&M
Power Supplies in Medical Electronics
Technical Article Power Supplies in Medical Electronics CONTENTS Introduction EN60950 and Level of Protection (LOP) Where IEC60601-1 differs from EN60950 Leakage Current Considerations Case Study: A Power
Construction Technologies Career Field Pathways and Course Structure
Courses in Structural Systems (DD) Construction Technologies Career Field Pathways and Course Structure PATHWAY COURSES SUBJECT CODE Construction Technology-Core and Sustainable Construction 1 178000 Carpentry
Risk Management and Cybersecurity for Devices that Contain Software. Seth D. Carmody, Ph.D. 12 th Medical Device Quality Congress March 18, 2015
Risk Management and Cybersecurity for Devices that Contain Software Seth D. Carmody, Ph.D. 12 th Medical Device Quality Congress March 18, 2015 Main Points Establish a Cybersecurity Risk Management Program
TAMARAC FIRE RESCUE INSTRUCTIONS FOR FIRE ALARM PRE-SUBMITTAL CHECKLIST
TAMARAC FIRE RESCUE INSTRUCTIONS FOR FIRE ALARM PRE-SUBMITTAL CHECKLIST In order to provide a comprehensive plan review in a timely manner, and to insure the design and installation of fire alarm systems
Software Development for Medical Devices
Software Development for Medical Devices Overcoming the Challenges of Compliance, Quality and Cost Software is fast becoming the differentiator for manufacturers of medical devices. The rewards of software
Requirements Management John Hrastar
Requirements Management John Hrastar NASA Project Management Conference March 30-31, 2004 University of Maryland Conference Center Introduction Three aspects of requirements management Requirements in