testo 6383 differential pressure transmitter testo 6610 Probes P2A software Parameterizing, adjusting and analyzing software
|
|
|
- Kevin Greer
- 10 years ago
- Views:
Transcription
1 testo 6383 differential pressure transmitter testo 6610 Probes P2A software Parameterizing, adjusting and analyzing software Instruction manual Volume 2
2 70
3 5 Content 5 Content 5 Content testo 6610 probes Specifications Functions and use Digital probes: The Testo humidity sensor Self-diagnosis Design of the probe Accessories Product description Overview of probe and filter types Probe version Determining the accuracy/measuring uncertainty Ordering options for testo 6610 probe ( ) Protection caps Integrated humidity probe testo 6613 cable probe testo 6614 heated cable probe testo 6615 trace humidity cable probe (self-adjustment) testo 6617 cable probe (self-monitoring) Self-monitoring of cover electrode Commissioning Installing the probe Installing testo 6613/6614/6615/6617 probes Connecting/removing the probe to/from the transmitter Maintenance and cleaning Replacing filters/protection caps Replacing the filter/protection caps for wall version Replacing the filter/protection cap for duct versions Cleaning the instrument and filter/protection cap Replacing the sensor Parameterizing, adjusting and analyzing software (P2A software) Specifications Functions and use System requirements Scope of delivery First steps Installing the software/driver Installing P2A software Installing USB driver P2A software upgrade Starting the software Starting the program Establishing a connection with the instrument Activating the connection with the instrument
4 5 Content 7.3. Using the software User interface Editing instrument/parameter file Changing instrument/parameter file Saving parameters Opening the parameter file Copying and pasting parameters Deleting instrument/parameter file Creating a new instrument file Analyzing/testing the transmitter Analyzing/testing the instrument Carrying out factory reset Testing analog output Testing switch output relays 1 to Displaying min./max. values Adjusting the transmitter point adjustment point adjustment n-point adjustment Adjusting the analog output Transmitter history Tips and assistance Questions and answers Accessories and spare parts Ordering options for testo 6383 transmitter ( ) Ordering options for testo 6610 probes ( )
5 6 testo 6610 probes 6 testo 6610 probes 6.1. Specifications Functions and use The plug-in, adjusted probes from the testo 6610 family are used together with the testo 6383 transmitter. These measuring units are suitable for the following applications, for example: Process instrumentation Clean rooms Test benches Drying processes Production and storage air quality Complex room climate applications Digital probes: The probes are adjusted in the factory and transmit their adjustment data to the internal memory of the testo 6383 transmitter. The information is only transmitted between the probes and transmitter digitally. The probes can therefore be disconnected from the transmitter for adjustment or servicing while the transmitter itself can remain at the measuring point. Hint: We recommend in this case that a probe of the same type be inserted into the transmitter immediately in order to be able to continue measuring with minimal interruption. The transmitter identifies the probe and records that a probe was connected in the history. The testo 6383 transmitter can only be used with testo 6610 probes The Testo humidity sensor With the Testo humidity sensor, which has been in successful use and continually improved for more than ten years, the focus has from the very beginning been on both accuracy parameters, namely measuring uncertainty and long-term stability. The capacitive humidity sensor is in principle a plate capacitor consisting of two electrically conductive plates (electrodes (1) and (2), see diagram below) opposite each other. 73
6 6 testo 6610 probes A humidity-sensitive polymer (5) serves as the dielectric. The special feature lies in the perfect way the individual layers are matched to each other. This is evident particularly in the top electrode, which has to perform two tasks that, at first glance, appear contradictory: it must be completely permeable to the water vapour that is to be fed into the polymer dielectric, but at the same time it must be impervious, smooth and repellent to condensate, oil and dirt in order to protect the sensor. 1 Cover electrode 2 Bottom electrode 3 Substrate (ceramic substrate for mechanical protection) 4 Connections (protected against corrosion) 5 Dielectric layer The humidity sensor cannot be exchanged by the customer (except for 6611). The humidity sensor may not be damaged or touched. Contamination and damage lead to an impairment of the measurement and the measuring accuracy Self-diagnosis The probes in the testo 6610 range monitor their functionality themselves and report the following faults: Sensor breaks Sensor short-circuit Condensation The condensation message is issued at a reading of 100 % RH and deactivated once the readings are within the valid range. Error message with drift at the adjustment points Value for relative humidity less than 0 % RH. The trigger threshold is set at -2 % RH. This means that an error message is only issued once a clear effect is discernible. Early warning when sensor corrosion is starting to develop The testo 6617 probe is able to signal the first signs of corrosion. The probe can thus be changed at an early stage without interrupting the machine availability. Self-adjustment (testo 6615 only) Excess temperature Error message if permissible process temperature is exceeded 74
7 6 testo 6610 probes Design of the probe The probes of the testo 6610 family are made up of the following components (included in delivery): Probe connector Probe shaft with protection cap and sensors (% RH and C or F) Probe cable bend radius minimum Ø 50 mm. 1 Probe connector 2 Probe length 3 Probe 4 Protection cap, sensor underneath 5 Probe Accessories The following accessories are available for the probes from the testo 6610 family: Filters and protection caps (see Overview of probe and filter types, page 76). Calibration certificate in accordance with ISO and DAkkS (see Accessories and spare parts, page 134). 75
8 6 testo 6610 probes 6.2. Product description Overview of probe and filter types Probe version A detailed description of the probe versions can be found from see Integrated humidity probe, page 79 onwards. The following probe versions are available for the testo 6383 transmitter: Version Article no. Characteristic Integrated humidity probe 76 KMAT option D04 ( ) Wall probe version; accuracy to ±1 % RH; temperature range -20 to +70 C/-4 to +158 F, plug-on sensor testo L12 Duct probe version; accuracy to ±1 % RH; temperature range -30 to +150 C/ -22 to +302 F, sensor soldered testo L13 Cable probe version; accuracy to ±1 % RH; temperature range C / F, sensor soldered testo L14 Heated cable probe version; accuracy to ±1 % RH; temperature range -40 to +180 C/ -40 to 356 F, sensor soldered testo L15 Trace humidity cable probe version; accuracy to ±6 K at -60 Ctd; temperature range -40 to +120 C/-40 to +248 F, sensor soldered testo L17 Cable with cover electrode monitoring probe version; accuracy to ±1.2 % RH; temperature range -40 to +180 C/ -40 to +356 F, sensor soldered Determining the accuracy/measuring uncertainty The entries for the measuring uncertainty for the probe are determined in accordance with GUM (Guide to the Expression of Uncertainty in Measurement/DIN V ENV 13005). All parts that make up the measuring uncertainty given by Testo are listed below. When comparing the measuring uncertainty/accuracy between manufacturers, which components are included is to be taken into account. In many cases, not all elements that contribute to measuring uncertainty are assessed, for example if the error contribution of the production adjustment for some manufacturers is shown separately or not at all.
9 6 testo 6610 probes The measuring uncertainty of the probe includes the sensor and its electronics as well as the output of the digital measuring signal: 1 Linearity including scatter Systematic error and scattering of the components (due to manufacturing tolerances) 2 Hysteresis Hysteresis indicates the maximum deviation of the readings that are obtained when you set the same value for the parameter, once coming from a smaller value, once coming from a larger value (humidity sensors actually have no hysteresis, but rather very slow adjustment effects that appear to be hysteresis when considered only for a short period.) 3 Reproducibility Repeatability (scattering of the readings in the event of the same parameter being entered successively) 4 Production adjustment area The measuring uncertainty of the reference instruments of the adjustment area (including the reference instrument) in production 5 Uncertainty of the testing Uncertainty of the procedure for determining points 1 and Ordering options for testo 6610 probe ( ) Order code Lxx Probe type Characteristic L12 Probe 6612 L13 Probe 6613 L14 Probe 6614 L15 Probe 6615 L17 Probe 6617 Mxx Protection caps M01 M02 M03 M04 M06 Protection cap made of stainless steel Protection cap made of wire mesh Protection cap made of PTFE Metal protection cap (open) PTFE protection cap with condensate drip hole 77
10 6 testo 6610 probes Order code M07 M08 Nxx Cable length Characteristic Protection cap made of PTFE with condensate drip hole and condensation protector Protection cap for H 2 O 2 atmospheres N01 1 m cable length (testo 6613, 6614, 6615, 6617) N02 2 m cable length (testo 6613, 6614, 6615, 6617) N05 5 m cable length (testo 6613, 6614, 6615, 6617) N10 10 m cable length (testo 6613, 6614, 6615, 6617) N23 Cable length specifically for duct versions (testo 6612) Pxx Probe length P12 Probe length approx. 120 mm (testo 6613) P20 Probe length approx. 200 mm (testo 6612, 6613, 6614, 6615, 6617) P30 Probe length approx. 300 mm (testo 6612, 6613) P50 Probe length approx. 500 mm (testo 6612, 6613, 6614, 6615, 6617) P80 Probe length approx. 800 mm (testo 6612, 6613) 78
11 6 testo 6610 probes Protection caps One of the following protection caps can be used for each probe version: Filter* Article no. ** Characteristic Length A (mm) M Protection cap made of stainless steel 33 M Protection cap made of wire mesh 40.3 M Protection cap made of PTFE 35 M Metal protection cap (open) 35 M PTFE protection cap with condensate drip hole 35 M Protection cap made of PTFE with condensate drip hole and condensation protector M /1 Protection cap for H 2 O 2 atmospheres * When ordering the probe, please use this protection cap code, cf. see Ordering options for testo 6610 probes ( ), page 140. ** When purchasing a replacement (protection cap only), please use this order number Integrated humidity probe The integrated humidity probe is mounted on the wall together with the ready-wired testo 6383 transmitter. At a glance 1 Protection cap 2 Probe shaft 3 Key 4 Connector 79
12 6 testo 6610 probes Application Monitoring and regulating the air quality in clean rooms Technical data Parameters Humidity (% RH/ C td / F td ) etc. Temperature Measuring range Humidity: 0 to 100 % RH Temperature: -20 to +70 C/-4 to +158 F Material Probe shaft: Stainless steel Connector: ABS plastic Accuracy (at 25 C/77 F)* Humidity 80
13 6 testo 6610 probes ± (1.0 % RH x reading) for 0 to 90 % RH ± (1.4 % RH x reading) for 90 to 100 % RH 0.02 % RH/K, dependent upon the process temperature (with a deviation of 25 C/+77 F) 0.02 % RH/K, dependent upon the electronics temperature (with a deviation of 25 C/+77 F) Temperature ±0.15 C (0.27 F) with slope PT1000 class AA * Refer to the charts below for the correlation between temperature and accuracy. Reproducibility Better than ±0.2 % RH Sensor Response time without protective filter: t 90 max. 15 s Probe dimensions Diameter of probe shaft: 12 mm L = approx. 47 mm L A = 32 mm A = approx. 32 mm Measuring accuracy of the integrated humidity probe Humidity error, absolute ±% RH as a factor of process humidity (% RH) Temperature error as a factor of process temperature and temperature of electronics 81
14 6 testo 6610 probes Grey line: System error probe, electronics 25 C/+77 F Black line: System error probe, electronics 25 to 70 C/-13 to 158 F testo 6613 cable probe The testo 6613 probe is used when the spatial separation of the transmitter and probe is required. At a glance 1 Connector 2 Key 3 Probe cable 4 Probe shaft 5 Protection cap (including: humidity and temperature sensor) WARNING In the event of overpressures, the probe may become a projectile. > Mount the probe pressure-tight (see pressure resistance under Technical data) Application Monitoring and regulating industrial humidity processes (apart from high-humidity processes), e.g. food production, storing fruit Monitoring the production and storage air quality when manufacturing and storing hygroscopic products 82
15 6 testo 6610 probes Meeting the top accuracy requirements Clean room applications Applications for which a sturdy metal housing is required. Testo recommends that the testo 6614 (heated) probe be used for continuous high-humidity processes. Technical data Parameters Humidity Temperature Measuring range Humidity: 0 to 100 % RH 7 Temperature: -70 to +180 C/-94 to +356 F 7 For constant use in high humidity (> 80% rf at 30 C for > 12 h, > 60% rf at > 30 C for > 12 h), please contact us via 83
16 6 testo 6610 probes Material Probe shaft: Stainless steel Line: Sheathed, FEP Connector: ABS plastic Accuracy (at 25 C/77 F)* Humidity ± (1.0 % RH x reading) for 0 to 90 % RH ± (1.4 % RH x reading) for 90 to 100 % RH 0.02 % RH/K, dependent upon the process temperature (with a deviation of 25 C/+77 F) 0.02 % RH/K, dependent upon the electronics temperature (with a deviation of 25 C/+77 F) Temperature ±0.15 C (0.27 F) with slope PT1000 class AA * Refer to the charts below for the correlation between temperature and accuracy. Reproducibility Better than ±0.2 % RH Sensor Response time without protective filter: t 90 max. 15 sec. Probe dimensions Diameter of probe shaft: 12 mm L = approx. 120/200/300/500/800 mm L A = 85/165/265/465/765 mm A, see Overview of probe and filter types, page 76. Probe length incl. probe shaft and filter 1/2/5/10 m Pressure resistance** PN 10 (probe tip) PN 1 (if end of probe/cable is involved in process) ** If installing probe under pressure, please use cutting ring screw connection (order no ). Measuring accuracy of testo 6613 cable probe Humidity error, absolute ±% RH as a factor of process humidity (% RH) 84
17 6 testo 6610 probes Temperature error as a factor of process temperature and temperature of electronics Grey line: System error probe, electronics 25 C/+77 F Black line: System error probe, electronics 25 to 70 C/-13 to 158 F 85
18 6 testo 6610 probes testo 6614 heated cable probe The testo 6614 heatable probe is suitable for use in high-humidity processes in which there is the possibility of condensation for the probe. Also see volume 1, High-humidity adjustment for testo 6614, page 35 for the functional principle of the testo At a glance 1 Connector 2 Key 3 Probe cable 4 Probe shaft 5 Filter (including: humidity and temperature sensor) 6 Temperature probe 7 Cable for temperature probe 8 Condensation protector ( ) WARNING In the event of overpressures, the probe may become a projectile. > Mount the probe pressure-tight (see pressure resistance under Technical data) Application Monitoring and regulating high-humidity processes, e.g. drying (ceramics, tobacco, wood, food) and maturing (cheese, fruit). At flow velocities > 1 m/s, an additional measuring uncertainty, not higher than +1.5 % RH, is to be expected. To prevent this error and ensure the highest measuring accuracy: Use condensation protector
19 6 testo 6610 probes 1 testo 6383 transmitter 2 testo 6614 heated cable probe 3 Temperature probe 4 Assembly distance max. 10 cm Technical data Parameters Humidity Temperature Measuring range Humidity: 0 to 100 % RH Temperature: -40 to C/-40 to 356 F Material Probe shaft: Stainless steel Line: Sheathed, FEP Connector: ABS plastic Accuracy (at 25 C/77 F)* Humidity (values valid when using condensation protector ) ± (1.0 % RH x reading) for 0 to 100 % RH 0.02 % RH/K, dependent upon the process temperature (with a deviation of 25 C/+77 F) 0.02 % RH/K, dependent upon the electronics temperature (with a deviation of 25 C/+77 F) Temperature ±0.15 C (0.27 F) with slope PT1000 class AA * Refer to the charts below for the correlation between temperature and accuracy. 87
20 6 testo 6610 probes Reproducibility ± 0.2 % RH better Sensor Response time without protective filter: t 90 max. 15 sec. Probe dimensions Diameter of probe shaft: 12 mm Diameter of temp. probe: 3 mm L = approx. 200/500 mm L A = 165/465 mm A see Overview of probe and filter types, page 76. Probe length incl. probe shaft and filter 1/2/5/10 m Pressure resistance** PN 10 (probe tip) PN 1 (if end of probe/cable is involved in process) ** If installing probe under pressure, please use cutting ring screw connection (order no ). Measuring accuracy of heated testo 6614 cable probe Humidity error, absolute ±% RH as a factor of process humidity (% RH) Temperature error as a factor of process temperature and temperature of electronics 88
21 6 testo 6610 probes Grey line: System error probe, electronics 25 C/+77 F Black line: System error probe, electronics 25 to 70 C/-13 to 158 F testo 6615 trace humidity cable probe (selfadjustment) The testo 6615 probe corrects deviations in measurements by means of self-adjustment. This has a particular significance with low humidity values (in dewpoint range). Also see volume 1, Self adjustment of testo 6615 trace humidity probe, page 36 for the functional principle of the testo Only use testo 6615 with sintered PTFE protection cap (art. no ) or sintered stainless steel protection cap (art. no ). During the self-adjustment phase the signal values of the analog outputs remain on hold, meaning they are frozen for the duration. At a glance 1 Connector 2 Key 3 Probe cable 4 Probe shaft 5 Protection cap (including: humidity and temperature sensor) 89
22 6 testo 6610 probes WARNING In the event of overpressures, the probe may become a projectile. > Mount the probe pressure-tight (see pressure resistance under Technical data) Application Monitoring and regulating trace humidity processes (compressed air with adsorption or membrane driers and plastic granulate driers) Used when spatial separation of transmitter and probe is required. 90 Technical data Parameters Dewpoint Temperature
23 6 testo 6610 probes Measuring range Dewpoint: -40 to + 30 C td /-148 to +212 F td Temperature: -40 to ±120 C/-40 to +248 F (Temp. durability up to +180 C/+356 F) Material Probe shaft: Stainless steel Line: Sheathed, FEP Connector: ABS plastic Accuracy (at 25 C/77 F)* Dewpoint ± 1 K at 0 C td /+32 F td ± 2 K at -40 C td /-40 F td ± 4 K at -50 C td /-58 F td ± 6 K at -60 C td /-76 F td Dependent on the process temperature (deviation of 25 C / 77 F) ± 0.1 Ktd/K at -40 C to 25 C/-40 F to +77 F ± 0.2 Ktd/K at 25 C to 50 C/77 F to 122 F ± 0.4 Ktd/K at 50 C to 120 C/122 F to 248 F Temperature ±0.15 C (0.27 F), slope PT1000 class AA * Refer to the charts below for the correlation between temperature and accuracy. Sensor Response time without protective filter: t 90 max. 15 sec. Probe dimensions Diameter of probe shaft: 12 mm L = approx. 200/500 mm L A = 165/465 mm A see Overview of probe and filter types, page 76. Cable length incl. probe shaft and filter 1/2/5/10 m Pressure resistance PN 16 (probe tip)** ** If installing probe under pressure, please use cutting ring screw connection (order no ). 91
24 6 testo 6610 probes Measuring accuracy of testo 6615 trace humidity cable probe Dewpoint error, absolute ±% RH as a factor of process dewpoint ( C td ) Temperature error as a factor of process temperature and temperature of electronics Grey line: System error probe, electronics 25 C/+77 F Black line: System error probe, electronics 25 to 70 C/-13 to 158 F 92
25 6 testo 6610 probes testo 6617 cable probe (self-monitoring) The testo 6617 probe is used if spatial separation of the transmitter and probe is required, particularly for media (gases, vapours) which can jeopardize/damage the humidity sensor (the testo 6617 has a self-monitoring and early-warning function for such applications). At a glance 1 Connector 2 Key 3 Probe cable 4 Probe shaft 5 Filter (including: humidity and temperature sensor) WARNING In the event of overpressures, the probe may become a projectile. > Mount the probe pressure-tight (see pressure resistance under Technical data) Application Monitoring and regulating industrial humidity processes involving corrosive media (apart from high-humidity processes) with the exception of applications with HCL, HF and other acids and acidifiers in larger concentrations (SO 2, SO 3, NO 2 ) Meeting the top accuracy requirements Applications for which a sturdy metal housing is required This probe does NOT have a longer life with exposure to aggressive media than the testo 6613, for example. However, early warning of damage to the sensor is given so that machine failures can be avoided. 93
26 6 testo 6610 probes Self-monitoring of cover electrode Use in harsh ambient conditions with aggressive media in some cases incurs the risk of damage to the sensor. Damage to the sensor is generally reflected by incorrect readings which occur a long time before the sensor is wrecked. If this damage to the sensor is not spotted until too late, high costs can be incurred due to unusable readings or machine shutdowns and waiting times until the sensor is replaced. 1 Cover electrode 2 Bottom electrode 3 Substrate (ceramic substrate for mechanical protection) 4 Connections (protected against corrosion) 5 Dielectric layer The testo 6617 has a unique self-monitoring function. This allows early detection of damage to the sensor, e.g.: Mechanical damage (e.g. scratches) Damage from aggressive gases (e.g. acids in aerosol form) Swelling or detachment of polymer layer due to effects of solvents Once the self-monitoring reaches the specific limit value, the probe warning message "Sensor early warning" is issued. 94
27 6 testo 6610 probes Technical data Parameters Humidity (% RH/ C td / F td ) Temperature Measuring range Humidity: 0 to 100 % RH 8 Temperature: -40 to +180 C/-40 to 356 F Material Probe shaft: Stainless steel Line: Sheathed, FEP Connector: ABS plastic 8 For constant use in high humidity (> 80% rf at 30 C for > 12 h, > 60% rf at > 30 C for > 12 h), please contact us via 95
28 6 testo 6610 probes Accuracy (at 25 C/77 F)* Humidity ± (1.2 % RH x reading) for 0 to 90 % RH ± (1.6 % RH x reading) for 90 to 100 % RH 0.02 % RH/K, dependent upon the process temperature (with a deviation of 25 C/+77 F) 0.02 % RH/K, dependent upon the electronics temperature (with a deviation of 25 C/+77 F) Temperature ±0.15 C (0.27 F) with slope PT1000 class AA * Refer to the charts below for the correlation between temperature and accuracy. Reproducibility Better than ±0.2 % RH Sensor Response time without protective filter: t 90 max. 15 sec. Probe dimensions Diameter of probe shaft: 12 mm L = approx. 200/500 mm L A = 165/465 mm A see Overview of probe and filter types, page 76. Probe length incl. probe shaft and filter 1/2/5/10 m Pressure resistance PN 10 (probe tip)** ** If installing probe under pressure, please use cutting ring screw connection (order no ). 96
29 6 testo 6610 probes Measuring accuracy of testo 6617 cable probe (selfmonitoring) Humidity error, absolute ±% RH as a factor of process humidity (% RH) Temperature error as a factor of process temperature and temperature of electronics Grey line: System error probe, electronics 25 C/+77 F Black line: System error probe, electronics 25 to 70 C/-13 to 158 F 97
30 6 testo 6610 probes 6.3. Commissioning Installing the probe Installing testo 6613/6614/6615/6617 probes If used with these probes, the testo 6383 transmitter is mounted on the wall, see volume 1, see Commissioning, page 20. Install probe according to the application and the measuring and spatial conditions, cf. cases A1 to C below In processes with which condensate forms at the humidity probe, install the probe vertically (filter points downwards). A 1 Wall mounting of probe 1 Wall/duct holder (order no ) A 2 Wall mounting of testo 6614 heated probe When mounting the testo 6614 heated probe version, the temperature probe must be secured as close to the humidity probe as possible (max. 10 cm). An appropriate assembly tool is supplied with the testo
31 6 testo 6610 probes 1 Wall/duct holder (order no ) 2 testo Distance of probe tips of humidity probe - temperature probe: As close as possible, but without touching (distance between probe tips max. 10 cm) 4 Assembly tool, supplied with the wall/duct holder (order no ) 5 Temperature probe B Duct mounting of testo 6614 heated probe When mounting the testo 6614 heated probe version, the temperature probe must also secured at a distance of approximately 10 cm from the humidity probe. An appropriate assembly tool is supplied with the testo
32 6 testo 6610 probes 1 Wall/duct holder (order no ) 2 testo Temperature probe 4 Assembly tool, supplied with the wall/duct holder (order no ) 5 Direction of flow 6 approx. 10 cm distance C Process mounting 1 Cutting ring screw connection (order no ) 100 During installation, ensure that the probe cannot be damaged during operation. For the testo 6614 (heated probe version), please use the cutting ring screw connection, order no , to assemble the temperature probe Connecting/removing the probe to/from the transmitter Insert probe connector into socket of testo 6383 until it engages. The testo 6383 identifies which probe is connected. To remove the probe, the lock release button on the probe must be pressed so that this can be removed.
33 6 testo 6610 probes 6.4. Maintenance and cleaning Replacing filters/protection caps Replacing the filter/protection caps for wall version Do not damage the sensors when exchanging the filter/the protection cap and do not touch their surfaces! 1. Unscrew defective filter/protection cap (2) from probe shaft (1). 2. Screw new filter/protection cap onto probe shaft. Screw on protection cap by hand, i.e. do not tighten it using a tool. 101
34 6 testo 6610 probes Replacing the filter/protection cap for duct versions The following descriptions applies to these probes: testo 6613 testo 6614 testo 6615 testo 6617 Do not damage the sensor when exchanging the filter/the protection cap and do not touch its surface! 1. Unscrew defective filter/protection cap (2) from probe shaft (1). 2. Screw new filter/protection cap onto probe shaft. Screw on protection cap by hand, i.e. do not tighten it using a tool. 102
35 6 testo 6610 probes Cleaning the instrument and filter/protection cap Only clean the instrument carefully with a moist cloth. Do not use aggressive cleaning agents. Do not use any solvents. Unscrew cap or protection cap to clean, clean with compressed air and replace. Take care not to damage the sensor! Replacing the sensor Thanks to the probe concept (digital, plug-in), all probes can be changed in situ within seconds if necessary, generally without any interruption to the operation of the machine. To maintain the extremely high accuracy of the testo 6610 probe, it is not possible for customers to change the sensor. Please contact your Testo Service team for this. 103
36 7 Parameterizing, adjusting and analyzing software (P2A software) 7 Parameterizing, adjusting and analyzing software (P2A software) 7.1. Specifications The P2A software is used for the parameterizing, adjustment and analysis of testo transmitters. The following applies: Generally, all newer testo transmitters (as of 2007) are supported. For each newly purchased Testo transmitter, a free software upgrade must be installed, containing the instrument drivers for all transmitters which are connectable at that time. This upgrade can be downloaded free of charge at any time from the Testo homepage (requires registration). The software must only be bought one time, even for owners of several testo transmitters Functions and use In the P2A software, two different file types are used: The instrument and the parameter file. Instrument file The parameters of a particular transmitter are stored in its so-called instrument file. Using this file, the parameters can be edited and the instrument can be tested and adjusted. Instrument files also contain the respective histories in addition to the parameter data, i.e. "log books" are kept for the previous parameterizations, adjustments and messages (see Transmitter history page 129). Instrument files are ".cfm" format files. Parameter file Parameter files are not tied to a specific individual transmitter and contain only parameter data/no history data. If you use various instruments of the same type, you can create parameter files once (e.g. by saving the appropriate instrument file as the parameter file) and transmit these onto the other instruments. Parameter files are ".cfp" format files. 104
37 7 Parameterizing, adjusting and analyzing software (P2A software) System requirements Operating system Windows XP Home/Professional SP3 Windows Vista Windows 7 Computer The computer must fulfil the requirements of the respective operating system. The following requirements must additionally be fulfilled: Interface USB 1.1 or higher Graphic resolution min x 768 Date and time settings are automatically taken over from the computer. The administrator must ensure that the system time is regularly synchronized with a reliable time source, in order to guarantee the authenticity of the data. Software The P2A software must be purchased and installed separately from the transmitter. If it is a new software version, the transmitter is already supported completely. Older P2A software versions can be updated via the P2A software upgrade Scope of delivery Included in the scope of delivery are: P2A software USB driver 7.2. First steps When working with the parameterizing, adjusting and analyzing software (P2A software), previous knowledge of Windows operating systems is assumed. The description in this instruction manual relates to Windows XP Installing the software/driver Adminstrator rights are required for installation. 105
38 7 Parameterizing, adjusting and analyzing software (P2A software) Installing P2A software 1. Insert CD with P2A software. If the installation program does not start automatically: > Open Windows Explorer and start the file Setup.exe on the product CD. 2. Follow the directions of the installation wizard Installing USB driver Before installing the USB driver, please read the separate documentation that is enclosed with the USB driver CD P2A software upgrade 1. Download and store P2A software upgrade from (requires registration). 2. Select folder into which the downloaded Zip file was stored, and unzip the file. 3. Start file P2A upgrade.exe. 4. Follow instructions from installation assistant Starting the software Starting the program > Click on [Start] Programs (Windows XP) or All Programs (Windows Vista, Windows 7) Testo P2A- Software. In Windows Vista/Windows 7 the window User account control is opened when starting the software the first time. > Click on Accept. - The program window is opened (see User interface page 107) Establishing a connection with the instrument The instrument works with limited functionality, if it is only supplied via the service plug. Some settings, which can be parameterized in the P2A software, will only be executed by the instrument, after it has been connected to the electric power supply. Multiple instruments can be attached, however only one connection is active at all times. USB driver is installed (see Installing USB driver page 106). 106
39 7 Parameterizing, adjusting and analyzing software (P2A software) 1. Start the P2A software. 2. Connect adapter (supplied with the P2A software) to the service interface of the instrument (see volume 1, Service interface page 15). 3. Connect instrument/adapter to the PC via the USB interface. - The instrument file of the attached instrument is shown in the file list Activating the connection with the instrument > Click on the desired instrument file. - The selected file is marked in colour and the connection with the instrument is activated. If a connection with the instrument is established when the program is started, the corresponding instrument file is marked automatically Using the software User interface 1 Menu bar: Menu Command Explanation File Open Shows the Windows dialogue for searching and opening files. 107
40 7 Parameterizing, adjusting and analyzing software (P2A software) Menu Command Explanation Save as Saves the parameters of an instrument or parameter file under a new name. Edit Copy Copies the parameters of the marked instrument or parameter file in the cache. Paste View Toolbar Status bar? Check instrument connections Service Information Pastes the parameters from the cache in the marked instrument or parameter file. Activates/deactivates the toolbar or status bar. Checks the connections to a connected instrument without the instrument having to be activated. A text file with the most important information on the computer and the software is opened via Display service data. Shows the version number of the P2A software. 2 Toolbar: Shows the Windows-compliant icons for editing. 3 File: Icon File Explanation Symbol shows a transmitter Symbol shows a transmitter with a red minus sign in the upper left corner Instrument file Instrument file Instrument file Connection to the instrument has been established. <Type> <Serial number>.cfm File name should not be changed. Instrument file Connection to the instrument has not been established. 108
41 7 Parameterizing, adjusting and analyzing software (P2A software) Icon File Explanation Symbol shows a transmitter with a white P for parameter file in the upper left corner Parameter file <Type> <Serial number> <Date> <Time>.cfp File name can be changed. The name can be selected freely, but it is recommended that you retain the reference to the instrument. Parameter files are always marked red; the parameter values they contain are only forwarded to the instrument after being transmitted to the instrument file. 4 Function buttons: Dialogues on editing and testing the instrument are opened by means of the buttons. [Change parameterization] see Changing instrument/parameter file page 110. [Test/analyze transmitter] see Chapter Analyzing/testing the transmitter page 119. [Adjusting the transmitter] see Chapter Adjusting the transmitter page 124. [Transmitter history] see Transmitter history page File information: Status An instrument file is selected A parameter file is selected Connection status Shown in the window Type, serial number, firmware version of the instrument. Type, serial number and firmware version of instrument for which the parameter file was created. Green = connection is active Red = connection is inactive 6 Status bar: Shows the current status when editing via the menu bar. 109
42 7 Parameterizing, adjusting and analyzing software (P2A software) Editing instrument/parameter file Changing instrument/parameter file The desired instrument/parameter file is marked. 1. Click on [Change parameterization]. - The Properties of <Instrument type> <Serial number> dialogue is opened with the Change parameterization register. If the parameters were transmitted from other parameter files into the instrument file, a message is shown with which you can transmit the new parameters to the connected instrument using [Yes]. > If the parameters should not be transmitted, click on [No]. 2. Change or enter parameters in the corresponding fields. Field Unit/ Analog output Explanation All analog outputs are parameterized in this mask. 110
43 7 Parameterizing, adjusting and analyzing software (P2A software) Field Unit/analog output (graphic) Scale minimum/ maximum Unit Signal delay (graphic) Explanation Unit: 0 to 1 V/5 V/10 V or 0 to 20 ma/4 to 20 ma. Vertical: Current version of the analog output (cannot be changed). Horizontal: Min./max. scale end points of selected unit. The curve changes in accordance with the entered value of scale minimum and maximum. The endpoints of the scaling can be selected up to the stored scale minimum and maximum. In the process, scaling can take place beyond the measuring range in order to adjust the analog output to the customer system, see volume 1, Scaling, page 17. Selection of the physical unit. When changing the unit, standard values are set for scale minimum and maximum. Caution! When changing the phys. unit, the relay limit values are set to the assigned default values. Curve changes according to the set signal delay. Signal delay Time interval in stages 1 15: 1 = no delay 15 = longest delay. The signal delay is added to the reaction time of the sensor. The signal delay shows averaging over the time interval of the selected stage in seconds: Example Stage 10 = average of the readings from the last 10 seconds. The delay of the signal in relation to the change in the process is also significantly influenced by the selection of the particle filter. 111
44 7 Parameterizing, adjusting and analyzing software (P2A software) Field Limit values, relay 1 to 4/alarm values, alarm 1 to 4 Explanation In this mask, the relays or display alarms are parameterized. Relay x/alarm x Not used Collective alarm Min control Four relays or alarm values are available (optional). Relay is not used. Hysteresis image and input options are hidden. A relay can be used as a collective alarm detector in the event that selected messages appear. Selection of the messages (OR linkage) by selecting the checkbox. If switched to ON (NO contact) or OFF (NC contact) under the limit value; in the event of a subsequent exceeding of Limit value plus Hysteresis, it is switched to OFF (NO contact) or ON (NC contact). 112
45 7 Parameterizing, adjusting and analyzing software (P2A software) Field Max control Explanation If switched to ON (NO contact) or OFF (NC contact) above the limit value; in the event of a subsequent undershooting of Limit value minus Hysteresis, it is switched to OFF (NO contact) or ON (NC contact). The graphic display in the centre of the screen refers to the relay wiring as a NO contact (ON). Hysteresis Channel Limit value Visual alarm display To avoid switching cycles. Selection of the channel that is to be monitored. Values for the limits of the unit selected in Unit/analog output; 4 decimal places. When changing the phys. unit, the relay limit values are set to the default values. Checkbox is activated: Upon the appearance of the selected alarm, the background lighting of the display and the corresponding measurement value flashes. 113
46 7 Parameterizing, adjusting and analyzing software (P2A software) Field Alarm delay Field Basic settings Explanation Explanation The desired alarm delay for the alarms of the min/max control and the visual alarm is entered in the input field (0 to 3600 seconds possible). The alarm delay has no effect on the collective alarms. Setting the absolute pressure and selection of the H 2 O 2 evaporation process for the parameter C tm ). Absolute pressure The absolute pressure is included in the calculation of the following units: C tda or F tda g/kg or gr/lb ppmv% vol. 114
47 7 Parameterizing, adjusting and analyzing software (P2A software) Field H 2 O 2 process Field Display Explanation The calculation of the mixture dewpoint unit C tm is dependent upon the type of the evaporation process: with passive vaporization: H 2 O 2 solution evaporates (with active vaporization) with active vaporization: H 2 O 2 solution is evaporated over a heated metal plate (with active vaporization) Input field: Entering the weight proportion of the liquid H 2 O 2 compared to water in %. Explanation Setting the display functions (if a display is available on the transmitter). Continuous display lighting Display lighting when button is pressed (10 seconds) Display lighting is permanently switched on. When a particular button on the instrument is pressed, the display lights up for 10 seconds. 115
48 7 Parameterizing, adjusting and analyzing software (P2A software) Field Display brightness (0 to 9) Display contrast (0 to 9) Display of the error messages Display language New password [Adopt new password] Valid password Field Zeroing cycle Explanation Setting the brightness between 0 and 9: 0 = dark 9 = light Setting the contrast between 0 and 9: 0 = low contrast 9 = high contrast Selection of whether the error messages should be shown in the display. Selection of the language. The password consists of four numbers, each of which must be between 1 and 9. If the password protection is not to be used, the numerical code "0000" must be entered. Button for confirming the new password. Display of the current password. Explanation Setting the interval of the automatic zeroing with solenoid valve. The accuracy specifications are only valid for the zeroing cycle of 15 sec set by the factory. 116
49 7 Parameterizing, adjusting and analyzing software (P2A software) Field Explanation Zeroing cycle setting Selection of the time interval after which the automatic zeroing cycle is to occur. Recommendation: 15 sec Field Self-adjustment Explanation Setting the self-adjustment. Activate selfadjustment for the testo 6615 probe Self-adjustment every Checkbox is activated: The selfadjustment is performed in the set cycle. Checkbox is not activated: The selfadjustment is not performed. Setting the cycletime in which the selfadjustment is to be performed. In order to receive reliable readings during the calibration or equalization period of the probe, testo recommends the shortest possible cycle time. A longer cycle time can be set in continuous operation. [Start self adjustment] Start self adjustment at a defined time outside the cycle time. 117
50 7 Parameterizing, adjusting and analyzing software (P2A software) Saving parameters Parameters can be saved in new parameter files. 1. Mark instrument/parameter file. 2. Click on File > Save as in the menu bar. 3. Select storage location and enter the file name. 4. Click on [Save]. - The new parameter file is shown in the file list. Only the parameters are saved from an instrument file; the history data are not adopted. The original name (Instrument type, Serial number) is suggested with the current date/time as standard, e.g. "testo cfp". For a standard installation, the files are saved under "C:\Documents and Settings\All Users\Shared Documents\P2A Software". The path can differ depending on the version of the operating system Opening the parameter file All parameter files stored in the standard directory path are automatically displayed in the file list when the software is started. You can also open parameter files that are stored in other directories. 1. Click on File > Open in the menu bar. 2. Select the storage location and click on the requisite file. 3. Click on [Open]. - The selected file is opened. This can be changed and saved (see Editing instrument/parameter file page 110) Copying and pasting parameters The parameters of a parameter file can be transmitted to an instrument file or another parameter file from the same instrument type. 1. Select file from which parameters are to be copied. 2. Click on Edit > Copy in the menu bar. 3. Select the file which is to be modified. 118
51 7 Parameterizing, adjusting and analyzing software (P2A software) 4. Click on Edit > Paste in the menu bar. - The parameters are transmitted to the file. You can also use the common keyboard shortcuts for copying (CTRL+C) and pasting (CTRL+V). Parameters can also be transmitted using drag & drop, where you drag the icon of the parameter file onto the icon of the target instrument file. 5. Connect and select corresponding instrument. 6. Click on [Change parameterization]. 7. Confirm confirmation request. - Parameter data are transferred to the instrument Deleting instrument/parameter file Instrument/parameter files can be deleted from the file list. 1. Click on the file that is to be deleted with the right mouse button. 2. Select the command Delete in the context menu. - The instrument or parameter file is deleted from the list Creating a new instrument file It is possible to create an instrument file without restarting the P2A software. Transmitter must be connected. 1. Click on File > New connection in the menu bar. - Connection to the transmitter is established Analyzing/testing the transmitter In this section, you can test the outputs of the connected instrument, read off the limit values and reset the parameters to the factory settings. The function is only available for instrument files Analyzing/testing the instrument The required instrument file is marked. 1. Click on [Test/analyze transmitter]. - The Properties of <Instrument type> <Serial number> dialogue is opened with the Test/analyze transmitter register. 119
52 7 Parameterizing, adjusting and analyzing software (P2A software) 2. Perform action: Action Carrying out factory reset Testing analog output Test switch outputs Display min./max. values Explanation Reset the unit, limit value and hysteresis parameters to factory settings (see below). Test channel 1/optional 2/3 (see Testing analog output, page 120). Manually switch relays 1 to 4 to test for proper function (see Testing switch output relays 1 to 4, page 122). Overview of the minimum and maximum values measured since the last reset of the transmitter (see Displaying min./max. values, page 123). 3. Click on [OK] or [Cancel] to close the dialogue Carrying out factory reset The required instrument file is marked. 1. Click on [Test/analyze transmitter]. - The Properties of <Instrument type> <Serial number> dialogue is opened with the Test/analyze transmitter register. 2. Mark transmitter test. - Current operating hours are shown. 3. Confirm control query to perform the reset. - The values are reset to the customer-specific factory settings. 4. Click on [OK] or [Cancel] to close the dialogue Testing analog output The required instrument file is marked. 1. Click on [Test/analyze transmitter]. - The Properties of <Instrument type> <Serial number> dialogue is opened with the Test/analyze transmitter register. 120
53 7 Parameterizing, adjusting and analyzing software (P2A software) 2. Mark channel and test values. Field/button Explanation Check the analog outputs (see volume 1, see Editing Main Menu Analysis, page 48). Current reading Unit Default value [Activate] [Deactivate] Readings are updated every second. Unit according to the type of analog output. Freely definable output value for the respective type of analog output (V or ma), 1 decimal place. The entered default value is forwarded to the corresponding analog output and to the test contacts by clicking. A warning informs that the value is being transmitted to the connected instrument in the event of existing cabling. Now check the analog output using a precise multimeter. Finish entering the electrical variables at the analog output. The analog output returns to the current reading again. 121
54 7 Parameterizing, adjusting and analyzing software (P2A software) 3. Click on [OK] or [Cancel] to close the dialogue. - The analog output and the relay return to Measuring Mode again Testing switch output relays 1 to 4 The required instrument file is marked. 1. Click on [Test/analyze transmitter]. - The Properties of <Instrument type> <Serial number> dialogue is opened with the Test/analyze transmitter register. 2. Mark Relay tests and test the values. Field/button Explanation Test the relay function (see volume 1, see Editing Main Menu Analysis, page 48). [Activate relay n] [Deactivate relay n] Close contact. A warning informs that the value is being transmitted to a connected PLC, external display, etc. in the event of existing cabling. Open contact. A warning informs that the value is being transmitted to a connected PLC, external display, etc. in the event of existing cabling. 122
55 7 Parameterizing, adjusting and analyzing software (P2A software) 3. Click on [OK] or [Cancel] to close the dialogue. - The analog output returns to Measuring Mode again Displaying min./max. values The transmitter saves the minimum or maximum value for each channel (measured since the last voltage supply or since the last manual reset). The required instrument file is marked. 1. Click on [Test/analyze transmitter]. - The Properties of <Instrument type> <Serial number> dialogue is opened with the Test/analyze transmitter register. 2. Mark Min./max. values. Field/button Min./max. values Explanation View the min./max. values of each channel. Only the values within the measuring range are shown. Channel Value Unit Min./max. of channel 1/2/3 (optional) Min. or max. value, 1 decimal place. Unit selected in Unit/analog output. 3. Reset Min./max. values. 4. Click on [Reset min./max. values]. 123
56 7 Parameterizing, adjusting and analyzing software (P2A software) 5. Confirm control query to perform the reset. - The values are reset to the factory settings. 6. Click on [OK] or [Cancel] to close the dialogue Adjusting the transmitter This function is used to adjust an attached instrument. The following adjustments may be carried out using the software: 1-point adjustment (offset) 2-point adjustment (upper and lower adjustment point) Analog adjustment (entry via assistant/wizard) n-point adjustment (entry via assistant/wizard) Also see volume 1, see Adjusting the instrument, page point adjustment The testo 400/650 with precision humidity probe (order no ) is recommended as the reference measuring instrument for 1-point adjustment (offset) (see Adjusting testo 6383 using testo handheld instrument, page 31). 1. Expose the reference measuring instrument and the instrument to be adjusted to the same constant conditions and wait for equalization period to lapse. 2. Mark the instrument file of the connected instrument. 3. Click on [Adjusting the transmitter]. - The Properties of <Instrument type> <Serial number> dialogue is opened with the Adjusting the transmitter register. 4. Enter reference value and click on [Carry out 1-point adjustment]. 124
57 7 Parameterizing, adjusting and analyzing software (P2A software) 5. Confirm confirmation request. - The adjustment is carried out. Field Explanation C/ F Current reading Reference value Selection of the unit; only for temperature adjustment. Reading in C/ F or % RH. Readings are updated every second. Entry of the read-off value from the reference measuring instrument. Permissible entries: max. 5 % RH deviation (sum of all 1-point adjustments) max. 2 K ( C) deviation (sum of all 1-point adjustments) > Click on [Set offset to zero] to reset a transmitted reference value. - The current reading is used again. 6. Click on [OK] or [Cancel] to close the dialogue. 125
58 7 Parameterizing, adjusting and analyzing software (P2A software) point adjustment Also see volume 1, volume 1, see 2-point adjustment (humidity/temperature), page Expose the reference measuring instrument and the instrument to be adjusted to the same constant conditions and wait for equalization period to lapse. 2. Mark the instrument file of the connected instrument. 3. Click on [Adjusting the transmitter]. - The Properties of <Instrument type> <Serial number> dialogue is opened with the Adjusting the transmitter register. 4. Mark 11.3 %, enter the reference value for the lower adjustment point and click on [Lower adjustment point]. - The adjustment is carried out. 5. Mark 75.3 %, enter the reference value for the upper adjustment point and click on [Upper adjustment point]. - The adjustment is carried out. Field Explanation Current reading Reference value Reading in % RH. Readings are updated every second. Entry of the read-off value from the reference measuring instrument. Permissible entries: Lower adjustment point 10.3 to 12.3 % RH Upper adjustment point 74.3 to 76.3 % RH. 6. Click on [OK] or [Cancel] to close the dialogue n-point adjustment 1. Connect precision pressure sensor (see volume 1, see n-point adjustment (pressure), page 34). 2. Mark the instrument file of the connected instrument. 3. Click on [Adjusting the transmitter]. - The Properties of <Instrument type> <Serial number> dialogue is opened with the Adjusting the transmitter register. 4. Mark n-point adjustment. 126
59 7 Parameterizing, adjusting and analyzing software (P2A software) 5. Click on [Start wizard ] and follow the instructions of the wizard. - The adjustment is performed when the wizard is closed. Field Explanation How much pressure is actually applied Required field: Entry of the value read off at the pressure sensor. The n-point adjustment must always be carried out to its full extent and in good time at all selected adjustment points. The number of adjustment points (3 to 6) is stored in the user menu of the transmitter and can only be changed via the P2A software Adjusting the analog output 1. Connect precision multimeter (see volume 1, see Analog output adjustment, page 33). 2. Mark the instrument file of the connected instrument. 3. Click on [Adjusting the transmitter]. - The Properties of <Instrument type> <Serial number> dialogue is opened with the Adjusting the transmitter register. 127
60 7 Parameterizing, adjusting and analyzing software (P2A software) 4. Click on [Start wizard ] and follow the instructions of the wizard. - The adjustment is performed when the wizard is closed. Field Explanation Default value Measured analog value The analog output value from the last performed adjustment is given at the output. Value of the factory adjustment: Lower adjustment point: approx. 10 % of the max. value Centre adjustment point: approx. 50 % of the max. value Upper adjustment point: approx. 90 % of the max. value Required field: Entry of the value read off at the multimeter. 128
61 7 Parameterizing, adjusting and analyzing software (P2A software) Transmitter history Parameterizations, adjustment processes and messages that have occurred are registered in the transmitter with an operating hours stamp. In the history overviews (explained later in more detail), past processes and events can be made visible. For parameter changes or adjustments that are performed directly at the instrument (via the user menu), "Transmitter" is entered in the User field and only the operating hour is entered in the Date/time field instead of operating hour/date/time. For entries that are performed using the P2A software, the name of the user logged into Windows appears in the User field, while the date/time and operating hour are shown in the Date/time field. 1. Mark the instrument file of the connected instrument. 2. Click on the [Transmitter history] button. - The Properties of <Instrument type> <Serial number> dialogue is opened with the Transmitter history register. 3. Click on the required entry in the list to change the display. Field Explanation Operating hours / date/time Operating hour/time stamp at which the change at the instrument was performed. 129
62 7 Parameterizing, adjusting and analyzing software (P2A software) Field User Comments Explanation Name with which the user is logged into the operating system. "Transmitter" entry if the change was performed at the instrument. Type of parameter change, e.g. "Unit of channel 1 from Pa to hpa". Selection of adjustment histories: 1-point adjustments / 2-point adjustments / Analog adjustments / n-point adjustments. Serial no. Probes Probe operating hour User Reference value Unit Reading Serial number of the probe. Operating hour of the probe at which the change at the instrument was performed. Name with which the user is logged into the operating system. "Transmitter" entry if the change was performed at the instrument. If no changes were performed, no value is displayed. Unit during the adjustment. 1-point adjustment: If no changes were performed, no value is displayed. 130
63 7 Parameterizing, adjusting and analyzing software (P2A software) Field Offset from Offset to Offset Pressure specification Explanation 1-point adjustment: Value before the adjustment. 1-point adjustment: Value after the adjustment. 2-point adjustment: Difference between target and actual value reported by instrument. n-point adjustment: Reference value set at the pressure sensor. Channel Analog adjustment: Channel 1 to n. Specification Multimeter Offset Analog adjustment: Actual value. Analog adjustment: Reference value set at the multimeter. Analog adjustment: Deviation at time of adjustment. Selection of probe adjustment histories: 1-point adjustments / 2- point adjustments / Error/status messages. Serial number Serial number of the transmitter to which the probe was connected at the time of the adjustment. 131
64 7 Parameterizing, adjusting and analyzing software (P2A software) Field Operating hour probe Unit Offset from Offset to Target value Reading Difference Error/status messages Explanation Operating hour of the probe at which the change at the instrument was performed. Unit during the adjustment. 1-point adjustment: Value before the adjustment. 1-point adjustment: Value after the adjustment. 2-point adjustment: Reference value. 2-point adjustment: Value before the adjustment. 2-point adjustment: Difference determined by instrument between target value and reading. Error/status messages: The error/status messages assigned to the probe. The table is shown only for error and status messages that were generated in the transmitter and were transferred and saved there via the connection to the P2A software. Operating hours Serial number Operating hour at which the message appeared in the instrument. Serial number of the instrument to which the message is assigned 132
65 7 Parameterizing, adjusting and analyzing software (P2A software) Field Message Type of message Explanation e.g. "Scaling changed". The scaling was changed. e.g. early warning, status message. > To print out the history data, click on [Print]. The printing job is automatically sent to the default printer for the operating system. With [Set up printer ] a different printer can be selected or the printout can be edited. 4. Click on [OK] or [Cancel] to close the dialogue. 133
66 8 Tips and assistance 8 Tips and assistance 8.1. Questions and answers Question Connection to instrument cannot be established A message appears on the display Malfunction (with and without display) When does a stable current reading appear? Possible causes/solution Check connection cable/plug contacts See volume 1, Status, warning and error messages, page 55 Analysis using the P2A software, see Analyzing/testing the transmitter, page 119 After approx. 20 seconds If we could not answer your question, please contact your dealer or Testo Customer Service. For contact details see the rear side of this document or the web page Accessories and spare parts Description Spare parts An overview of the probes that can be used with the testo 6383 can be found in volume 1, see Overview of probe and filter types, page 76. Article no. Integrated humidity probe Sealing frame Protection Cap for the built-in humidity probe Interface and software P2A software (parameterizing, adjusting, analyzing) incl. USB adapter testo 400/650 adapter Dewpoint measurement (only with testo 6615) Preliminary filter to protect measurement chamber and sensors against contamination Precision chamber with adjustable inflow
67 8 Tips and assistance Flow meter for measurement chamber for setting the specified inflow of the sensor Cooling coil for process temperatures > 50 C/122 F (up to 200 C/392 F), only with precision measurement chamber 2 m PTFE tube with compressed air connections up to 140 C/284 F, max hpa, only with precision measurement chamber Protection caps Protection cap made of stainless steel (for integrated probe ) Protection cap made of stainless steel Woven wire filter protection cap Protection cap made of PTFE Metal protection cap (open) PTFE protection cap with condensate drip hole Protection cap made of PTFE with condensation protector and condensate drip hole Protection cap for H 2 O 2 atmospheres /1 Hoses Silicone hose ID 4 transparent TYGON hose ID 4.8 transparent Silicone hose transparent, internal diameter 2 mm, for test pressure connections 6383 Supply , sold by the metre , sold by the metre , sold by the metre Mains unit (desktop, wall-mounted) Mains unit (top-hat rail mounting) Extension and calibration cable External display Process display for testo 54-2 AC Process display for testo 54-7 AC
68 8 Tips and assistance Calibration Standard ISO calibration certificate, transmitter only Standard DAkkS calibration certificate, transmitter only Standard ISO calibration certificate, transmitter + probes Special ISO calibration certificate, transmitter + probes Standard DAkkS calibration certificate, transmitter + probes Special DAkkS calibration certificate, transmitter + probes ISO calibration certificate humidity, probes DAkkS calibration certificate temperature, probes For a complete list of all accessories and spare parts, please refer to the product catalogues and brochures or look up our website at: 136
69 8 Tips and assistance Ordering options for testo 6383 transmitter ( ) Order code Axx Measuring range A01 A02 A03 A04 A05 A21 A22 A23 A24 A25 Bxx Analog output/supply B02 B03 B04 B05 B06 Cxx Display C00 C02 C03 C04 C05 C06 C07 C08 Dxx Integrated humidity probe D00 Characteristic 0 to 50 Pa 0 to 50 Pa 0 to 100 Pa 0 to 500 Pa 0 to 10 hpa -10 to 10 Pa -50 to 50 Pa -100 to 100 Pa -500 to 500 Pa -10 to 10 hpa 0 to 1 V (4-wire, 24 V AC/DC) 0 to 5 V (4-wire, 24 V AC/DC) 0 to 10 V (4-wire, 24 V AC/DC) 0 to 20 ma (4-wire, 24 V AC/DC) 4 to 20 ma (4-wire, 24 V AC/DC) Without display With display/english With display/german With display/french With display/spanish With display/italian With display/japanese With display/swedish No humidity/temperature probe 137
70 8 Tips and assistance Order code D04 D05 Exx Ethernet E00 E01 Fxx Differential pressure unit 9 F01 F02 F03 F04 F05 F06 F07 F08 F09 F10 Gxx Optional analog output for humidity probe connection testo 6610/units 10 G01 G02 G03 G04 G05 G06 G07 Characteristic Humidity/temperature probe integrated in panel Preparation for external humidity/temperature probe testo 6610 probe Without Ethernet interface With Ethernet interface Pa/Min/Max hpa/min/max kpa/min/max mbar/min/max bar/min/max mmh 2 O /Min/Max inchh 2 O /Min/Max inch HG/Min/Max kg/cm 2 /Min/Max PSI/Min/Max % RH/Min/Max C/Min/Max F/Min/Max C td /Min/Max F td /Min/Max g/kg /Min/Max gr/lb /Min/Max 9 Scaling +/- 50 % of measuring range possible 10 Only if D04 or D05 is selected 138
71 8 Tips and assistance Order code G08 G09 G10 G11 G12 G13 G14 G15 G16 G17 G18 Hxx Relay H00 H01 H02 Ixx Units, channel 3 (only if optional humidity probe connection is available) 11 I01 I02 I03 I04 I05 I06 I07 I08 I09 Characteristic g/m 3 /Min/Max gr/ft 3 /Min/Max ppmv/min/max C wb /Min/Max F wb /Min/Max kj/kg /Min/Max (enthalpy) mbar/min/max (water vapour partial pressure) inch H 2 O/Min/Max (water vapour partial pressure) C tm (dewpoint for H mixture) F tm (dewpoint for H mixture) % vol Without relay 4 relay outputs, limit value monitoring 4 relay outputs, channel 1 limit values and collective alarm % RH/Min/Max C/Min/Max F/Min/Max C td /Min/Max F td /Min/Max g/kg /Min/Max gr/lb /Min/Max g/m 3 /Min/Max gr/ft 3 /Min/Max 11 Only if D04 or D05 is selected 139
72 C 8 Tips and assistance Order code I10 I11 I12 I13 I14 Characteristic ppmv/min/max C wb /Min/Max F wb /Min/Max kj/kg /Min/Max (enthalpy) mbar/min/max (water vapour partial pressure) I15 inch H 2 O/Min/Max (water vapour partial pressure) I16 C tm (dewpoint for H mixture) I17 F tm (dewpoint for H mixture) I18 % vol I19 %RH m (mixture humidityfor H ) Ordering options for testo 6610 probes ( ) Order code Lxx Probe type Characteristic L12 Probe 6612 L13 Probe 6613 L14 Probe 6614 L15 Probe 6615 L17 Probe 6617 Mxx Protection caps M01 M02 M03 M04 M06 M07 M08 Nxx Cable length Protection cap made of stainless steel Protection cap made of wire mesh Protection cap made of PTFE Metal protection cap (open) PTFE protection cap with condensate drip hole Protection cap made of PTFE with condensate drip hole and condensation protector Protection cap for H 2 O 2 atmospheres 140
73 8 Tips and assistance Order code Characteristic N02 1 m cable length (testo 6613, 6614, 6615, 6617) N03 2 m cable length (testo 6613, 6614, 6615, 6617) N04 5 m cable length (testo 6613, 6614, 6615, 6617) N05 10 m cable length (testo 6613, 6614, 6615, 6617) N06 Pxx Probe length P12 P20 P30 P50 P80 Cable length specifically for duct versions (testo 6612) Probe length approx. 120 mm (testo 6613) Probe length approx. 200 mm (testo 6612, 6613, 6614, 6615, 6617) Probe length approx. 300 mm (testo 6612, 6613) Probe length approx. 500 mm (testo 6612, 6613, 6614, 6615, 6617) Probe length approx. 800 mm (testo 6612, 6613) 141
74 8 Tips and assistance 142
75 8 Tips and assistance 143
76 en 02 V01.12 V en Vol2
testo 6383 Ethernet differential pressure transmitter testo 6610 Probes P2A software Parameterizing, adjusting and analyzing software
testo 6383 Ethernet differential pressure transmitter testo 6610 Probes P2A software Parameterizing, adjusting and analyzing software Instruction manual Volume 2 78 5 Contents 5 Contents 5 Contents...
testo 6681 Humidity transmitters testo 6610 Probes P2A software Parameterizing, adjusting and analyzing software Instruction manual Volume 2
testo 6681 Humidity transmitters testo 6610 Probes P2A software Parameterizing, adjusting and analyzing software Instruction manual Volume 2 en Contents 71 Contents 2 TESTO 6610 PROBES...73 2.1 Specifications...73
testo 6381 differential pressure transmitter testo 6610 Probes P2A software Parameterizing, adjusting and analyzing software
Pos: 84 /TD/Überschriften/MUF/2 Fühler testo 6610 @ 3\mod_1234258446543_79.doc @ 23913 @ 1 testo 6381 differential pressure transmitter testo 6610 Probes P2A software Parameterizing, adjusting and analyzing
testo 6651 Humidity transmitters testo 6600 Probes P2A software Parameterizing, adjusting and analyzing software Instruction manual Volume 2
testo 6651 Humidity transmitters testo 6600 Probes P2A software Parameterizing, adjusting and analyzing software Instruction manual Volume 2 en Contents 63 Contents 2 TESTO 6600 PROBES...64 2.1 Specifications...64
testo 6721 Dew point monitor P2A software for testo 6721 Instruction manual
testo 6721 Dew point monitor P2A software for testo 6721 Instruction manual en 2 Contents 3 Contents de Contents 3 Safety and the environment 4 Part 1: testo 6721 Specifications 5 Commissioning 8 Assembling
testo EasyClimate Software Instruction manual
testo EasyClimate Software Instruction manual 2 1 Contents 1 Contents 1 Contents... 3 1.1. About this document... 5 2 Specifications... 5 2.1. Use... 5 2.2. System requirements... 6 3 First steps... 6
idex Manual Contact details Producer: FOCI BV. The Netherlands www.foci.nl [email protected]
idex USB Manual Contact details Producer: FOCI BV. The Netherlands www.foci.nl [email protected] 2 Index Index... 3 1. General... 4 2. Get started!... 5 3. First use... 7 4. FOCI idex Software... 14 5. Operating
Measurement data monitoring with testo Saveris Small Business Edition. Instruction manual
Measurement data monitoring with testo Saveris Small Business Edition Instruction manual 2 1 Contents 1 Contents 1 Contents... 3 2 Safety and the environment... 7 2.1. About this document... 7 2.2. Ensure
ABB i-bus EIB / KNX Analogue Input AE/S 4.2
Product Manual ABB i-bus EIB / KNX Analogue Input AE/S 4.2 Intelligent Installation Systems This manual describes the functionality of Analogue Input AE/S 4.2. Subject to changes and errors excepted. Exclusion
Instruction Manual. T3111 T3111L T3111P T3111Ex
www.cometsystem.cz Instruction Manual T3111 T3111L T3111P T3111Ex Programmable transmitter of temperature, relative humidity and other calculated humidity values with external probe and 4-20 ma outputs
Pressure Dew Point Probe 0636.9840 / 0636.9841 Application Information
Pressure Dew Point Probe 0636.9840 / 0636.9841 Application Information en Contents Instrument description...3 User instructions...4 Safety instructions...5 Folding ferrite...5 Operating instructions...6
Highly efficient flue gas analyzer
Highly efficient flue gas analyzer testo 320 Just a few clicks away from a heating system diagnosis O 2 High-resolution colour graphic display Quick and easy menu structure Storage space for 500 measurement
Monitoring Network DMN
Monitoring Network DMN User Manual Table of contents Table of contents... 2 1. Product features and capabilities... 3 2. System requirements... 5 3. Getting started with the software... 5 3-1 Installation...
How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)
transmitter (2 wire) / switch for continuous or On/Off Control Indication, monitoring, transmitting and continuous or On/Off control in one device Output signal 4...20 ma, 2-wire for continuous control
Digital inductive conductivity transmitter
Digital inductive conductivity transmitter Optimal solution for conductivity measurements in difficult fluids (polluted, dirty,...) PEEK/PPA version for CIP applications Large range of process connections
Automation and Systems Technology. LABCONTROL TFM/TPM User Manual TroxMConnect Operating Software. 1. Introduction 1. 2. Software Installation 2
1. Introduction 1 2. Software Installation 2 2.1 System Requirements 2 2.2 TroxMConnect Installation 2 2.3 Connection to the PC 3 3. TroxMConnect Description 4 3.1 Starting the Software 4 3.2 Layout 4
Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5
Model Number Single head system Features Parameterization interface for the application-specific adjustment of the sensor setting via the service program ULTRA 000 programmable switch outputs Hysteresis
Duct Humidity Transmitter
SDC-H Duct Humidity Transmitter Features Replaceable sensor element Humidity measurement for air ducts Minimum and maximum value memory 0 0V, 0 0mA or 0V, 4 0mA measuring signals selectable with jumpers
Measurement data monitoring system
We measure it. Measurement data monitoring system testo Saveris Automated and uninterrupted measurement data recording C Stationary and mobile data monitoring in one system Flexible system set-up with
Electronic Pressure Switch EDS 300
Electronic Pressure Switch EDS 300 User manual Page 2 of 16 Content 1. Functions of the EDS 300...3 2. Mounting...3 3. Operating keys on the membrane keypad...4 4. Digital display...4 5. Output function...5
Sturdy aluminium housing, anodized in blue Female connector for optical fiber (please order optical fiber separately) Mounting holes
SI-COLO Series SI-COLO2-LWL-HAMP-COL4 - Big measuring range: typ. 25 mm... 40 mm (with optical fiber and attachment optics KL-14 or KL-17) - Large assortment of optical fibers available (reflected or transmitted
User Guide. Heavy Duty Dissolved Oxygen Meter. Model 407510
User Guide Heavy Duty Dissolved Oxygen Meter Model 407510 Introduction Congratulations on your purchase of Extech's Heavy Duty Dissolved Oxygen / Temperature Meter which simultaneously displays Dissolved
BUSINESS. Elektronisches Türschloss. Installation and User Manual. www.burg-waechter.de. Ingeniously safe. Ingeniously simple.
Elektronisches Türschloss BUSINESS Set 5011 PINCODE Set 5012 FINGERSCAN Set 5013 E-KEY Ingeniously safe. Ingeniously simple. BA/MA TSE Set 5000 dp/fsc 04/2012 Installation and User Manual BURG-WÄCHTER
EL-USB-2-LCD FEATURES WINDOWS CONTROL SOFTWARE DISPLAY FUNCTIONS. www.lascarelectronics.com Page 1 of 5
This standalone data logger measures and stores up to 16,379 relative humidity and 16,379 temperature readings over 0 to 100%RH and -35 to +80 C (-31 to +176 F) measurement ranges. The user can easily
T0118 T2118 T3118. Instruction Manual
Programmable indoor transmitter of temperature T0118 Programmable indoor transmitter of atmospheric pressure T2118 Programmable indoor transmitter of temperature, relative humidity and other derived humidity
Manual for Fire Suppression & Methane Detection System
Manual for Fire Suppression & Methane Detection System Fogmaker North America Post address: 150 Gordon Dr Exton, PA 19341 Delivery address: 150 Gordon Dr Exton, PA 19341 Tel: 610-265-3610 Fax: 610-265-8327
Combi B PC software 8213X. Installation and operating instructions
Combi B PC software 8213X Installation and operating instructions EN Table of Contents 1 Important notes... 3 2 Glossary of abbreviations and terms... 4 3 Symbols and special font types used... 5 4 Scope
Korosi Monitoring System (KMS) Software Manual
PT. KOROSI SPECINDO Corrosion Monitoring System Eng. Doc. No.: KS-MNL-KMS Korosi Monitoring System (KMS) Software Manual Revision Date Prepared Approved Description 0 23/05/2008 ES JH Issued for approval
Test equipment for temperature and its reduction
Data sheet 90.2721 Page 1/6 Test equipment for temperature and its reduction Pt100 precision RTD temperature probe Calibrated temperature measuring chain with precision display device Calibrations as service
DAS202Tools v1.0.0 for DAS202 Operating Manual
DAS202Tools v1.0.0 for DAS202 Operating Manual DAT102Tools 1.0.0 Manual Table of context 2 Table of Contents 1 General Information... 3 2 PC... Configuration Requirements 3 3 Software Installation... 3
UM-X Field display for continous level sensors
Technical Documentation Field display for continous level sensors 10/2007 Edition: 1 Item No.: 207120 FAFNIR GmbH Bahrenfelder Str. 19 D-22765 Hamburg Telephone: +49 (0)40-39 82 07-0 Fax: +49 (0)40-3 90
RI-215A Operator s Manual. Part Number: 71-0045RK Revision 0 Released: 10/3/05
RI-215A Operator s Manual Part Number: 71-0045RK Revision 0 Released: 10/3/05 Warranty RKI Instruments, Inc., warrants gas alarm equipment sold by us to be free from defects in materials and workmanship,
PTPhoneManager II. User guide
COMMUNICATION AT ITS BEST PTPhoneManager II User guide Communications A member of PEIKER group DOCUMENT PEI TEL Communications GmbH - PTPhoneManager II - 2 - T ABLE OF CONTENTS Table of contents Table
Getting started with
PART NO. CMA113 MADE IN CHINA 1. Measuring CAT II 2. Max. voltage 250V ~ 3. Max. current 71 Amp Getting started with Electricity consumption monitoring single phase for homes and some smaller light commercial
Transmitter Interface Program
Transmitter Interface Program Operational Manual Version 3.0.4 1 Overview The transmitter interface software allows you to adjust configuration settings of your Max solid state transmitters. The following
Doc.No. NDP 192U-02. Electric Pump Controller CE-124P. Instruction Manual
Doc.No. NDP 192U-02 Electric Pump Controller CE-124P Instruction Manual 1. Parts Name and Function 1) POWER LED Indicate that CE-124P is powered up. 2) START/STOP KEY (SELECTOR KEY) Used to start and stop
ImagineWorldClient Client Management Software. User s Manual. (Revision-2)
ImagineWorldClient Client Management Software User s Manual (Revision-2) (888) 379-2666 US Toll Free (905) 336-9665 Phone (905) 336-9662 Fax www.videotransmitters.com 1 Contents 1. CMS SOFTWARE FEATURES...4
SOFTWARE GUIDE PM1405 DATA PROCESSING SOFTWARE
SOFTWARE GUIDE PM1405 DATA PROCESSING SOFTWARE Equipment Software Manufacturer Survey meter РМ1405 "РМ1405 Software" Polimaster Copyright Polimaster 2015. All rights reserved. According Copyright protection
Falcon Protector Tracking System
Falcon Protector Tracking System Product Overview The Falcon Protector is a GPS and GSM tracking device which is specially developed and designed for vehicle tracking. With the latest SIFR III GPS module
USB-500/600 Series Low-Cost Data Loggers and Accessories
Low-Cost Data Loggers and Accessories Features Stand-alone, remote data loggers and portable logger assistant Measure temperature, humidity, voltage, current, or event/state change 1 or 2 channels Low
SPC-1. Single Point Controller. Operation Manual
SPC-1 Single Point Controller Operation Manual NOTICE: PPM Technology Limited shall not be liable for errors that may appear herein or for incidental or consequential damages in connection with or arising
SA-9600 Surface Area Software Manual
SA-9600 Surface Area Software Manual Version 4.0 Introduction The operation and data Presentation of the SA-9600 Surface Area analyzer is performed using a Microsoft Windows based software package. The
FCC COMPLIANCE STATEMENT FOR AMERICAN USERS
FCC COMPLIANCE STATEMENT FOR AMERICAN USERS This equipment has been tested and found to comply with the limits for a CLASS A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed
Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2. Instruction Manual
Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2 Instruction Manual Firmware version: 2.0.1 Issue: 0.6 Version of the GPRS transmitters configurator: 1.3.6.3 Date of issue: 07.03.2012 TABLE OF CONTENTS
Operating Instructions for the Software Fingerprint Access System FP530
GB Operating Instructions for the Software Fingerprint Access System FP530 Table of Contents GB Page 1. Introduction...3 2. Short description of the FP530-PC software...3 3. Explanation of Symbols...3
Quick Start Using DASYLab with your Measurement Computing USB device
Quick Start Using DASYLab with your Measurement Computing USB device Thank you for purchasing a USB data acquisition device from Measurement Computing Corporation (MCC). This Quick Start document contains
Network Video Recorder Quick Operation Guide
Network Video Recorder Quick Operation Guide UD.6L0202B1283A01 TABLE OF CONTENTS NVR Pre-Installation... 2 NVR Installation... 2 Hard Disk Installation... 2 Front Panel... 4 Rear Panel... 5 Specifications...
ETS4 Diagnostics. KNX Association
ETS4 Diagnostics Table of Contents 1 Diagnostics and fault location... 3 2 Diagnostics: Individual addresses...... 4 2.1 Devices in Programming Mode... 4 2.2 Checking if an address exists and locating
Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS
Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS up to size 381; to PN 0.5; to T = 80 C 1. Description 1.1. General FSA fluid level gauges, FSK fluid level sensors and TS temperature
USB-500 Series Low-Cost Data Loggers and Accessories
Low-Cost Data Loggers and Accessories Features Stand-alone, remote data loggers and portable logger assistant Measure temperature, humidity, voltage, current, or event/state change 1 or 2 channels Low
EASIDEW PORTABLE HYGROMETER INSTALLATION, OPERATION AND MAINTENANCE MANUAL
EASIDEW PORTABLE HYGROMETER INSTALLATION, OPERATION AND MAINTENANCE MANUAL Issue February 2004 2 TABLE OF CONTENTS SECTION PAGE 1. INTRODUCTION 3 1.1 General 3 1.2 Ceramic Sensing Element 3 1.3 Calibration
CAN MONITOR. Technische Alternative elektronische Steuerungsgerätegesellschaft mbh. A-3872 Amaliendorf, Langestr. 124, Fax 02862 53635 7 CAN-MT/F
Technische Alternative elektronische Steuerungsgerätegesellschaft mbh. A-3872 Amaliendorf, Langestr. 124, Fax 02862 53635 7 CAN-MT/F Vers.: E2.04EN CAN MONITOR The CAN monitor is a display and operating
site monitoring Kit Site Monitoring Kit User Manual we prove it.
site monitoring Kit 1 User Manual Site Monitoring Kit User Manual we prove it. 2 site monitoring Kit Content 1. Introduction 3 2. Content of the Site Monitoring Kit 4 3. Preparation 6 1. Positioning of
GREISINGER electronic GmbH
T38.0.0X.6C-03 CO2 - Transmitter Operating Manual GT10 - CO2-1R GREISINGER electronic GmbH D - 93128 Regenstauf, Hans-Sachs-Straße 26 Tel.: +49 9402 / 9383-0, Fax: +49 9402 / 9383-33, email: [email protected]
3M Wrist Strap and Footwear Tester 740. User s Guide
3M Wrist Strap and Footwear Tester 740 User s Guide Table of Contents Section Page Safety Information...3 1.0 General...4 2.0 Description...4 3.0 Operation...5 4.0 Wall Mounting...5 5.0 Wrist Strap Test...6
Datalogger Graph Software Help
Datalogger Graph Software Help Version 2.0, August 07, 2007 For additional information refer to the user guide included on the supplied program disk. TABLE OF CONTENTS Installing Graph Software....2 Installing
Electronic Pressure Switch EDS 3000
For Your Information Electronic Pressure Switch EDS 3000 User Manual Revision: November 01, 2002 1. EDS 3000 Functions The EDS 3000 unit offers the following functions: Display pressure in psi, MPa, or
Instruction Manual Service Program ULTRA-PROG-IR
Instruction Manual Service Program ULTRA-PROG-IR Parameterizing Software for Ultrasonic Sensors with Infrared Interface Contents 1 Installation of the Software ULTRA-PROG-IR... 4 1.1 System Requirements...
How To Program An Autodialer
GJD HYL005 GSM Autodialer Instruction Manual Please read these instructions before you start the installation Features: LCD display. Programmable 9 x 32 digit phone numbers for each trigger. 10 second
How do I configure the wireless printer using a USB or Ethernet cable and install the printer driver in Windows?
How do I configure the wireless printer using a USB or Ethernet cable and install the printer driver in Windows? STEP I: Gather the wireless network settings of your wireless access point or wireless router
Config software for D2 systems USER S MANUAL
DT-CONFIG SOFTWARE Config software for D2 systems USER S MANUAL CONTENTS 1. Introductions ------------------------------------------------------------------- 3 2. System Requirement and Connection ----------------------------------------
User Manual. Humidity-Temperature Chart Recorder. Model RH520
User Manual Humidity-Temperature Chart Recorder Model RH520 Introduction Congratulations on your purchase of the Extech RH520 Temperature + Humidity Chart Recorder. The RH520 measures and displays Temperature,
SOUND LEVEL METER 94405
SOUND LEVEL METER 94405 INSTRUCTION MANUAL REC FAST A/C 1. SAFETY INFORMATION Read the following safety information carefully before attempting to operate or service the meter. Use the meter only as specified
Hygro-Thermometer + InfraRed Thermometer Model RH101
User's Guide Hygro-Thermometer + InfraRed Thermometer Model RH101 Introduction Congratulations on your purchase of the Extech Hygro-Thermometer plus InfraRed Thermometer. This device measures relative
for CS flow / dew point sensors
Operating Manual Service Software for CS flow / dew point sensors FA300/ VA300/ DP300/ FA4XX / VA4XX - 1 - V-3-03-2008 Service Software for flow / dew point sensors Introduction This service software can
Operating instructions Platform/floor scales
KERN & Sohn GmbH Ziegelei 1 D-72336 Balingen email: [email protected] Phone: +49-[0]7433-9933-0 Fax: +49-[0]7433-9933-149 Internet: www.kern-sohn.com Operating instructions Platform/floor scales KERN
HOBO U14 Data Logger User Manual
HOBO U14 Data Logger User Manual The U family of data loggers offers reliability and convenient monitoring for applications that require higher accuracy, better resolution, more memory, or USB connectivity
Water Leak Detection System
Water Leak Detection System Installation and Operating Manual 505-334-5865 ph 505-334-5867 fax www.rodisystems.com email:[email protected] 936 Highway 516 Aztec, NM 87410-2828 Manual Revisions and Copyright
GSM AD05 Slave GSM Auto Dialer- Instruction Manual
GSM AD05 Slave GSM Auto Dialer- Instruction Manual Please read these instructions before you start the installation Features LCD display Programmable 9 x 32 digit phone numbers for each trigger. 10 second
4-Channel Thermometer / Datalogger
USER GUIDE 4-Channel Thermometer / Datalogger RTD and Thermocouple Inputs Model SDL200 Introduction Congratulations on your purchase of the Extech SDL200 Thermometer, an SD Logger Series meter. This meter
MOUNTING AND OPERATING INSTRUCTIONS
MOUNTING AND OPERATING INSTRUCTIONS CF 51/55 1. Delivery CF 51/55-1 calculator with battery (optionally with mains power supply) - 1 wall mounting bracket - package with material for sealing, screws, wall
MAKING MODERN LIVING POSSIBLE. living connect. Installation and User Guide. Danfoss heating
MAKING MORN LIVING POSSIBLE Danfoss heating living connect Installation and User Guide Contents 1.0 System overview... 3 2.0 Overview of display and control buttons... 3 3.0 Installation - step by step...
Committing to the future. Everything under control: With testo Saveris TM, measurement data are under control everywhere.
Committing to the future Everything under control: With testo Saveris TM, measurement data are under control everywhere. Unlimited data monitoring. Whether stationary or mobile. The data monitoring system
FLOW CALCULATOR INSTRUCTION MANUAL MESURES BAMOPHOX 759 26-06-2007 759 M1 02 E MES FLOW CALCULATOR 759-02/1
BAMOPHOX 759 E - M FLOW CALCULATOR INSTRUCTION MANUAL MESURES 22, Rue de la Voie des Bans - Z.I. de la Gare - 95100 ARGENTEUIL Tél : (33) 01 30 25 83 20 - Web : www.bamo.fr Fax : (33) 01 34 10 16 05 -
Operating ambient temperature range: 5ºC to 50ºC Storage temperature range: -30ºC to 70ºC
HOJA TÉCNICA 1400H101 Edición 01 (02 de 08) www.ako.es GENERAL TECHNICAL SPECIFICATIONS Temperature range: -50ºC to +99ºC type: NTC Total accuracy ( + controller): ±1ºC lead extension with cable AKO-15586:
OPL BASIC. Dosing System for Professional Laundry machines. Contents
OPL BASIC Dosing System for Professional Laundry machines Contents 1 Getting Started. Page 2 2 Installation. Page 4 3 Set Up & Operation. Page 8 4 Maintenance & Accessories. Page 10 5 Troubleshooting Page
USB 2.0 VGA ADAPTER USER MANUAL
USB 2.0 VGA ADAPTER USER MANUAL CONTENTS INTRODUCTION... 3 FEATURES... 3 SYSTEM REQUIREMENTS... 3 PACKAGE CONTENTS... 3 SUPPORTED COMMON DISPLAY RESOLUTION... 4 TECHNICAL SPECIFICATIONS... 4 INSTALLATION
Instruction manual. testo easyemission Software
Instruction manual testo easyemission Software en 2 General Information General Information This documentation includes important information about the features and application of the product. Please read
ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL
RANCO INSTALLATION INSTRUCTIONS ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL Relay Electrical Ratings PRODUCT DESCRIPTION The Ranco ETC is a microprocessor-based family of electronic temperature controls,
2/8.10.01. These vacuum switches are used in measuring ranges between -1 and 0 bar.
CATALOGUE > Release 8.5 > Electronic vacuum switches Series SWM Electronic miniature vacuum switches Series SWM These vacuum switches are used in measuring ranges between -1 and 0 bar. Small dimension
PLC Control Unit for a CSM-C Steam Compact Clean Steam Generator
3.635.5275.251 IM-P486-19 CH Issue 2 PLC Control Unit for a CSM-C Steam Compact Clean Steam Generator Installation, Start-up and Operation Manual 1. Safety information 2. General product information 3.
RACEAIR REMOTE PAGER SYSTEM
Computech Systems, Inc. 301-884-5712 30071 Business Center Dr. Charlotte Hall, MD 20622 RACEAIR REMOTE PAGER SYSTEM TM Introduction: Computech s RaceAir Remote Competition Weather Station with the Data
Device configurator DRC200
Operating manual 42/49-27 EN Engineer IT Device configurator DRC200 R&C Process Data Management Software Impressum Device configurator DRC200 Operating manual Document No. 42/49-27 EN Date of issue: 11.02
PolyGard Carbon Monoxide CO Transmitter ADTX3 1110
PolyGard Carbon Monoxide CO Transmitter ADTX3 1110 DESCRIPTION CO transmitter including digital measurement value processing and temperature compensation for the continuous monitoring of the ambient air
Technical data. General specifications. Indicators/operating means. Electrical specifications Operating voltage U B Power consumption P 0 Interface
Release date: 06-0- 09: Date of issue: 06-0- 009_eng.xml Model Number Single head system Features Parameterization interface for the application-specific adjustment of the sensor setting via the service
Using the enclosed installation diagram, drill three holes in the wall with the lower hole 1150mm from the floor.
Terminal Installation When choosing the location of the terminal, care should be taken to select an area with consistent light levels throughout the day and avoid areas where the unit may be subjected
VP23, 3-way proportional pressure control valves Seat valve with μp-driven pressure control
VP, -way proportional pressure control valves > > Port size: G/... G/ > > All-digital control electronics > > Variable pressure control > > Optional actuation via fieldbus (separate datasheet on request)
Ventostat Wall Mount. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. GE Measurement & Control. Features:
GE Measurement & Control Ventostat Wall Mount Telaire Wall Mount, Humidity and Temperature Transmitters Features: Patented, Absorption Infrared Gas sensing engine provides high accuracy in a compact low
LED red (-): Measuring value < lower tolerance threshold LED red (+): Measuring value > upper tolerance threshold. Page 1/6
L-LAS Series L-LAS-LT-165-CL - Line laser 1 mw, laser class 2 - Visible laser line (red light 670 nm), typ. 2 mm x 3 mm - Reference distance approx. 165 mm - Measuring range typ. 65... 265 mm - Resolution
VENTIsupport Version 1
Description and Operating Instructions VENTIsupport Version 1 Compliance and titration software Content 1. Description.............................2 1.1 Purpose............................2 1.2 Labelling............................2
Installing the IF-NMEASC & SC30 Windows XP Drivers & Software
Installing the IF-NMEASC & SC30 Windows XP Drivers & Software The following document will outline the installation and use of the IF-NMEASC and SC-30 USB drivers and SC-30Tool software in three parts:
ActiView. Visual Presenter Image Software User Manual - English
ActiView Visual Presenter Image Software User Manual - English Date: 05/02/2013 Table of Contents 1. Introduction... 3 2. System Requirements... 3 3. Install ActiView - Windows OS... 4 4. Install ActiView
REGTRONIC OPERATING INSTRUCTIONS
REGTRONIC OPERATING INSTRUCTIONS 1.FEATURES Electrical connection: M12 8-pin connector Preset pressure range 0.05-10 bar with possible full scale regulation. 10 100 mbar adjustable deadband Supply pressure:
Multi-Touch Control Wheel Software Development Kit User s Guide
Multi-Touch Control Wheel Software Development Kit User s Guide V3.0 Bulletin #1204 561 Hillgrove Avenue LaGrange, IL 60525 Phone: (708) 354-1040 Fax: (708) 354-2820 E-mail: [email protected] www.grayhill.com/instinct
GSM HOME SECURITY SYSTEM
Cell /Mobile phone home security system GSM HOME SECURITY SYSTEM Model : GSM-120 TABLE OF CONTENTS 1. FEATURES... 1 2. APPLICATION... 2 3. SPECIFICATIONS... 3 4. FRONT PANEL & LAYOUT DESCRIPTION...6 5.
Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate
1 919 1919P01 1919P03 QBM65/C, QBM75-1U/C Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate QBM751-1/C QBM65/C QBM75/C Highly accurate measurements with calibration
SystemGuard. Brief Description. Benefits. SystemGuard Main Window
SystemGuard Issue May 2009 Product SystemGuard Pages 8 Brief Description SystemGuard is an application software (published under freeware terms and conditions) from Fujitsu Technology Solutions which can
Instruction manual. testo easyheat Configuration and Analysis software
Instruction manual testo easyheat Configuration and Analysis software en 2 General Information General Information This documentation includes important information about the features and application of
RS Stock No. 724-4207 Instruction Manual RS-1340 Hot Wire Anemometer
RS Stock No. 724-4207 Instruction Manual RS-1340 Hot Wire Anemometer EN FR IT DE ES CONTENTS / EN Title CONTENTS Page 1. SAFETY INFORMATION...1 2. INTRODUCTION...2 3. SPECIFICATIONS...3 4. PARTS & CONTROLS...4
JEROME COMMUNICATIONS SOFTWARE (JCS) INSTALLATION and OPERATION MANUAL V1.02 for Windows XP
AZI P/N 700-0042-B Last update May 2009 USER MANUAL JEROME COMMUNICATIONS SOFTWARE (JCS) INSTALLATION and OPERATION MANUAL V1.02 for Windows XP May 2009 ARIZONA INSTRUMENT LLC 3375 N Delaware Street Chandler,