ANSI/NETA ATS-2013 STANDARD FOR ACCEPTANCE TESTING SPECIFICATIONS FOR ELECTRICAL POWER EQUIPMENT AND SYSTEMS
|
|
|
- Annice Waters
- 10 years ago
- Views:
Transcription
1 STANDARD FOR ACCEPTANCE TESTING SPECIFICATIONS FOR ELECTRICAL POWER EQUIPMENT AND SYSTEMS
2
3 AMERICAN NATIONAL STANDARD STANDARD FOR ACCEPTANCE TESTING SPECIFICATIONS for Electrical Power Equipment and Systems Secretariat InterNational Electrical Testing Association Approved by American National Standards Institute
4 This page intentionally left blank
5 American National Standard Approval of an American National Standard requires verification by ANSI that the requirements for due process, consensus, and other criteria for approval have been met by the standards developer. Consensus is established when, in the judgment of the ANSI Board of Standards Review, substantial agreement has been reached by directly and materially affected interests. Substantial agreement means much more than a simple majority, but not necessarily unanimity. Consensus requires that all views and objections be considered, and that a concerted effort be made toward their resolution. The use of American National Standards is completely voluntary; their existence does not in any respect preclude anyone, whether he has approved the standards or not, from manufacturing, marketing, purchasing, or using products, processes, or procedures not conforming to the standards. The American National Standards Institute does not develop standards and will in no circumstances give an interpretation of any American National Standard in the name of the American National Standards Institute. Requests for interpretations should be addressed to the secretariat or sponsor whose name appears on the title page of this standard. Caution Notice: This American National Standard may be revised or withdrawn at any time. The procedures of the American National Standards Institute require that action be taken periodically to reaffirm, revise, or withdraw this standard. Purchasers of American National Standards may receive current information on all standards by calling or writing the American National Standards Institute. Published by InterNational Electrical Testing Association 3050 Old Centre Ave., Suite 102 Portage, MI FAX [email protected] Jayne Tanz - Executive Director Copyright 2013 InterNational Electrical Testing Association All rights reserved Printed in the United States of America No part of this publication may be reproduced in any form, in an electronic retrieval system or otherwise, without the prior written permission of the publisher.
6 Copyright Information and Alteration of Content 2013 ANSI/NETA Standard for Acceptance Testing Specifications for Electrical Power Equipment and Systems () is protected under the copyright laws of the United States, and all rights are reserved. Further, the may not be copied, modified, sold, or used except in accordance with such laws and as follows: Purchasers may reproduce and use all or a portion of the provided ANSI/NETA Standard for Acceptance Testing Specifications for Electrical Power Equipment and Systems are clearly identified in writing as the source of all such uses or reproductions. Section 7 of the ANSI/NETA Standard for Acceptance Testing Specifications for Electrical Power Equipment and Systems may be reproduced and used on a cut and paste basis for the particular type of equipment to be tested. The following sections of the ANSI/NETA Standard for Acceptance Testing Specifications for Electrical Power Equipment and Systems must be incorporated by reference as part of any subsection: 3. Qualifications of Testing Organization and Personnel 3.1 Testing Organization 3.2 Testing Personnel 4. Division of Responsibility 4.1 The Owner s Representative 4.2 The Testing Organization 5. General 5.1 Safety and Precautions 5.2 Suitability of Test Equipment 5.3 Test Instrument Calibration 5.4 Test Report The purchaser is required to include the above sections with any section(s) of 7. Copyright 2013 InterNational Electrical Testing Association 3050 Old Centre Avenue, Suite 102 Portage, MI [email protected] Web:
7 Standards Review Council These specifications were submitted for public comment and reviewed by the NETA Standards Review Council. Charles K. Blizard, Sr. Timothy J. Cotter Diane W. Hageman Roderic L. Hageman David Huffman Ralph Patterson Alan D. Peterson Jayne Tanz Ron Widup Ballot Pool Members for ANSI/NETA Standard for Acceptance Testing Specifications for Electrical Power Equipment and Systems, 2013 Ken Bassett Tom Bishop Scott Blizard Michael Bowers John Cadick Michel Castonguay Ernie Creech Tim Crnko Thomas Domitrovich Lorne Gara David Geary Don Genutis Paul Hartman Kerry Heid Andrew Kobler Korey Kruse Benjamin Lanz Mark Lautenschlager Jerry Parnell Lee Perry Tony Perry Mose Ramieh Randall Sagan Peter Sammy Richard Sobhraj Tim Thomas Alan Turpen Wally Vahlstrom Chris Werstiuk John White JP Wolff
8 NOTICE In no event shall the InterNational Electrical Testing Association be liable to anyone for special, collateral, incidental, or consequential damages in connection with or arising out of the use of these materials. This document is subject to periodic review, and users are cautioned to obtain the latest edition. Comments and suggestions are invited from all users for consideration by the Association in connection with such review. Any such suggestions will be fully reviewed by the Association after giving the commenter, upon request, a reasonable opportunity to be heard. This document should not be confused with federal, state, or municipal specifications or regulations, insurance requirements, or national safety codes. While the Association recommends reference to or use of this document by government agencies and others, use of this document is purely voluntary and not binding. InterNational Electrical Testing Association 3050 Old Centre Avenue, Suite 102 Portage, MI Voice: Facsimile: [email protected] Web: Jayne Tanz, CMP - Executive Director
9 FOREWORD (This Foreword is not part of American National Standard ) The InterNational Electrical Testing Association (NETA) was formed in 1972 to establish uniform testing procedures for electrical equipment and apparatus. NETA developed specifications for the acceptance of new electrical apparatus prior to energization and for the maintenance of existing apparatus to determine its suitability to remain in service. The first NETA Acceptance Testing Specifications for Electrical Power Equipment and Systems was produced in Upon completion of this project, the NETA Technical Committee began work on a maintenance document, and Maintenance Testing Specifications for Electrical Power Equipment and Systems was published in NETA has been an Accredited Standards Developer for the American National Standards Institute since NETA's scope of standards activity is different from that of the IEEE, NECA, NEMA, and UL. In matters of testing electrical equipment and systems NETA continues to reference other standards developers documents where applicable. NETA's review and updating of presently published standards takes into account both national and international standards. NETA s standards may be used internationally as well as in the United States. NETA firmly endorses a global standardization. IEC standards as well as American consensus standards are taken into consideration by NETA's Section Panels and reviewing committees. The NETA Acceptance Testing Specifications was developed for use by those responsible for assessing the suitability for initial energization of electrical power equipment and systems and to specify field tests and inspections that ensure these systems and apparatus perform satisfactorily, minimizing downtime and maximizing life expectancy. Since 1972, several revisions of the Acceptance Testing Specifications have been published; in 1989 the NETA Technical Committee, with approval of the Board of Directors, set a four-year review and revision schedule. Unless it involves a significant safety or urgent technical issue, each comment and suggestion for change is held until the appropriate review period. Each edition includes new and completely revised sections. The document uses the standard numbering system of ANSI and IEEE. Since 1989, revised editions of the Acceptance Testing Specifications have been published in 1991, 1995, 1999, 2003, 2007, and On January 25, 2013 the American National Standards Institute approved the NETA Acceptance Testing Specifications for Electrical Power Equipment and Systems as an American National Standard. Suggestions for improvement of this standard are welcome. They should be sent to the InterNational Electrical Testing Association, 3050 Old Centre Avenue, Suite 102, Portage, MI
10 PREFACE It is recognized by the Association that the needs for acceptance testing of commercial, industrial, governmental, and other electrical power systems vary widely. Many criteria are used in determining what equipment is to be tested and to what extent. To help the user better understand and navigate more efficiently through this document, we offer the following information: Notation of Changes Material included in this edition of the document but not part of the 2009 edition is marked with a black vertical line to the left of the insertion of text, deletion of text, or alteration of text. The Document Structure The document is divided into twelve separate and defined sections: Section Section 1 Section 2 Section 3 Section 4 Section 5 Section 6 Section 7 Section 8 Section 9 Section 10 Tables Appendices Description General Scope Applicable References Qualifications of Testing Organization and Personnel Division of Responsibility General Power System Studies Inspection and Test Procedures System Function Test Thermographic Survey Electromagnetic Field Testing Reference Tables Various Informational Documents Section 7 Structure Section 7 is the main body of the document with specific information on what to do relative to the inspection and acceptance testing of electrical power distribution equipment and systems. It is not intended that this document list how to test specific pieces of equipment or systems. Expected Test Results Section 7 consists of sections specific to each particular type of equipment. Within those sections there are, typically, three main bodies of information: 1. Visual and Mechanical Inspection 2. Electrical Tests 3. Test Values
11 PREFACE ( ) Results of Visual and Mechanical Inspections Some, but not all, visual and mechanical inspections have an associated test value or result. Those items with an expected result are referenced under Section 3.1 Test Values Visual and Mechanical. For example, Section 7.1 Switchgear and Switchboard Assemblies, item calls for verifying tightness of connections using a calibrated torque wrench method. Under the Test Values Visual and Mechanical Section , the expected results for that particular task are listed within Section 3.1, with reference back to the original task description on item INSPECTION AND TEST PROCEDURES 7.1 Switchgear and Switchboard Assemblies 1. Visual and Mechanical Inspection 1. Compare equipment nameplate data with drawings and specifications. 2. Inspect physical and mechanical condition. 3. Inspect anchorage, alignment, grounding, and required area clearances. 4. Verify the unit is clean and all shipping bracing, loose parts, and documentation shipped inside cubicles have been removed. 5. Verify that fuse and circuit breaker sizes and types correspond to drawings and coordination study as well as to the circuit breaker s address for microprocessor-communication packages. 6. Verify that current and voltage transformer ratios correspond to drawings. 7. Verify that wiring connections are tight and that wiring is secure to prevent damage during routine operation of moving parts. 8. Inspect bolted electrical connections for high resistance using one or more of the following methods: 1. Use of a low-resistance ohmmeter in accordance with Section Verify tightness of accessible bolted electrical connections by calibrated torque-wrench method in accordance with manufacturer s published data or Table Perform thermographic survey in accordance with Section Verify operation and sequencing of interlocking systems. 10. Verify appropriate lubrication on moving current-carrying parts and on moving and sliding surfaces. 11. Inspect insulators for evidence of physical damage or contaminated surfaces. 12. Verify correct barrier and shutter installation and operation. 7. INSPECTION AND TEST PROCEDURES 7.1 Switchgear and Switchboard Assemblies ( ) 3. Test Values 3.1 Test Values Visual and Mechanical 1. Compare bolted connection resistance values to values of similar connections. Investigate values which deviate from those of similar bolted connections by more than 50 percent of the lowest value. ( ) 2. Bolt-torque levels shall be in accordance with manufacturer s published data. In the absence of manufacturer s published data, use Table ( ) 3. Results of the thermographic survey shall be in accordance with Section 9. ( ) 3.2 Test Values Electrical 1. Compare bolted connection resistance values to values of similar connections. Investigate values which deviate from those of similar bolted connections by more than 50 percent of the lowest value. 2. Insulation-resistance values of bus insulation shall be in accordance with manufacturer s published data. In the absence of manufacturer s published data, use Table Values of insulation resistance less than this table or manufacturer s recommendations should be investigated. Dielectric withstand voltage tests shall not proceed until insulation-resistance levels are raised above minimum values. 3. If no evidence of distress or insulation failure is observed by the end of the total time of voltage application during the dielectric withstand test, the test specimen is considered to have passed the test. 4. Minimum insulation-resistance values of control wiring shall not be less than two megohms. 5. Results of electrical tests on instrument transformers shall be in accordance with Section Results of ground-resistance tests shall be in accordance with Section Accuracy of meters shall be in accordance with Section Exercise all active components. 14. Inspect mechanical indicating devices for correct operation. 15. Verify that filters are in place and vents are clear. 16. Perform visual and mechanical inspection of instrument transformers in accordance with Section * Optional * Optional Page 24 Page 27
12 PREFACE ( ) Results of Electrical Tests Each electrical test has a corresponding expected result, and the test and the result have identical numbers. If the electrical test is item four, the expected result under the Test Values section is also item four. For example, under Section Rotating Machinery, AC Induction Motors and Generators, item (item 2 within the Electrical Tests section) calls for performing an insulation-resistance test in accordance with IEEE Standard 43. Under the Test Values Electrical section, the expected results for that particular task are listed in the Test Values section under item INSPECTION AND TEST PROCEDURES Rotating Machinery, AC Induction Motors and Generators 1. Visual and Mechanical Inspection 1. Compare equipment nameplate data with drawings and specifications. 2. Inspect physical and mechanical condition. 3. Inspect anchorage, alignment, and grounding. 4. Inspect air baffles, filter media, cooling fans, slip rings, brushes, and brush rigging. 5. Inspect bolted electrical connections for high resistance using one or more of the following methods: 1. Use of low-resistance ohmmeter in accordance with Section Verify tightness of accessible bolted electrical connections by calibrated torque-wrench method in accordance with manufacturer s published data or Table Perform thermographic survey in accordance with Section 9. *6. Perform special tests such as air-gap spacing and machine alignment. *7. Manually rotate the rotor and check for problems with the bearings or shaft. *8. Rotate the shaft and measure and record the shaft extension runout. 9. Verify the application of appropriate lubrication and lubrication systems. 10. Verify that resistance temperature detector (RTD) circuits conform to drawings. 2. Electrical Tests AC Induction 1. Perform resistance measurements through bolted connections with a low-resistance ohmmeter, in accordance with Section Perform insulation-resistance tests in accordance with ANSI/IEEE Standard Machines larger than 200 horsepower (150 kilowatts): Test duration shall be ten minutes. Calculate polarization index. 2. Machines 200 horsepower (150 kilowatts) and less: Test duration shall be one minute. Calculate dielectric-absorption ratio for 60/30 second periods. 7. INSPECTION AND TEST PROCEDURES Rotating Machinery, AC Induction Motors and Generators ( ) 2. Compare bolted connection resistance values to values of similar connections. Investigate values which deviate from those of similar bolted connections by more than 50 percent of the lowest value. ( ) 3. Bolt-torque levels shall be in accordance with manufacturer s published data. In the absence of manufacturer s published data, use Table ( ) 4. Results of the thermographic survey shall be in accordance with Section 9. ( ) 5. Air-gap spacing and machine alignment shall be in accordance with manufacturer s published data. ( ) 3.2 Test Values Electrical Tests 1. Compare bolted connection resistance values to values of similar connections. Investigate any values that deviate from similar bolted connections by more than 50 percent of the lowest value. 2. The recommended minimum insulation resistance (IR 1 min) test results in megohms shall be in accordance with Table The polarization index value shall not be less than The dielectric absorption ratio shall not be less than If no evidence of distress or insulation failure is observed by the end of the total time of voltage application during the dielectric withstand test, the test specimen is considered to have passed the test. 4. Investigate phase-to-phase stator resistance values that deviate by more than five percent. 5. Power-factor or dissipation-factor values shall be compared to manufacturer s published data. In the absence of manufacturer s published data these values will be compared with previous values of similar machines. 6. Tip-up values shall indicate no significant increase in power factor. 7. If no evidence of distress, insulation failure, or lack of waveform nesting is observed by the end of the total time of voltage application during the surge comparison test, the test specimen is considered to have passed the test. 8. Bearing insulation-resistance measurements shall be within manufacturer s published tolerances. In the absence of manufacturer s published tolerances, the comparison shall be made to similar machines. * Optional * Optional Page 126 Page 128
13 Optional Tests PREFACE (Continued) The purpose of these specifications is to assure that all tested electrical equipment and systems supplied by either contractor or owner are operational and within applicable standards and manufacturer s published tolerances and that equipment and systems are installed in accordance with design specifications. Certain tests are assigned an optional classification. The following considerations are used in determining the use of the optional classification: 1. Does another listed test provide similar information? 2. How does the cost of the test compare to the cost of other tests providing similar information? 3. How commonplace is the test procedure? Is it new technology? Manufacturer s Instruction Manuals It is important to follow the recommendations contained in the manufacturer s published data. Many of the details of a complete and effective testing procedure can be obtained from this source. Summary The guidance of an experienced testing professional should be sought when making decisions concerning the extent of testing. It is necessary to make an informed judgment for each particular system regarding how extensive a procedure is justified. The approach taken in these specifications is to present a comprehensive series of tests applicable to most industrial and larger commercial systems. In smaller systems, some of the tests can be deleted. In other cases, a number of the tests indicated as optional should be performed. Likewise, guidance of an experienced testing professional should also be sought when making decisions concerning the results of test data and their significance to the overall analysis of the device or system under test. Careful consideration of all aspects of test and calibration data, including manufacturer s published data and recommendations, must be included in the overall assessment of the device or system under test. The Association encourages comment from users of this document. Please contact the NETA office or your local NETA Accredited Company. Standards Review Council InterNational Electrical Testing Association Charles K. Blizard, Sr. Timothy J. Cotter Diane W. Hageman Roderic L. Hageman David Huffman Ralph Patterson Alan D. Peterson Jayne Tanz Ron Widup
14 This page intentionally left blank
15 CONTENTS 1. GENERAL SCOPE APPLICABLE REFERENCES 2.1 Codes, Standards and Specifications Other Publications Contact Information QUALIFICATIONS OF TESTING ORGANIZATION AND PERSONNEL 3.1 Testing Organization Testing Personnel DIVISION OF RESPONSIBILITY 4.1 The Owner s Representative The Testing Organization GENERAL 5.1 Safety and Precautions Suitability of Test Equipment Test Instrument Calibration Test Report Test Decal POWER SYSTEM STUDIES 6.1 Short-Circuit Studies Coordination Studies Arc-Flash Hazard Analysis Load Flow Studies Stability Studies Harmonic-Analysis Studies INSPECTION AND TEST PROCEDURES 7.1 Switchgear and Switchboard Assemblies Transformers, Dry-Type, Air-Cooled, Low-Voltage, Small Transformers, Dry-Type, Air-Cooled, Large Transformers, Liquid-Filled Cables, Low-Voltage, Low-Energy - Reserved Cables, Low-Voltage, 600-Volt Maximum Cables, Medium- and High-Voltage Metal-Enclosed Busways Switches, Air, Low-Voltage Switches, Air, Medium-Voltage, Metal-Enclosed Switches, Air, Medium- and High-Voltage, Open Switches, Oil, Medium-Voltage Switches, Vacuum, Medium-Voltage Switches, SF 6, Medium-Voltage Switches, Cutouts Circuit Breakers, Air, Insulated-Case/Molded-Case Circuit Breakers, Low-Voltage Power Circuit Breakers, Air, Medium-Voltage Circuit Breakers, Oil, Medium- and High-Voltage Circuit Breakers, Vacuum, Medium-Voltage Circuit Breakers, SF Circuit Switchers... 89
16 CONTENTS 7.8 Network Protectors, 600-Volt Class Protective Relays, Electromechanical and Solid-State Protective Relays, Microprocessor-Based Instrument Transformers Metering Devices Metering Devices, Microprocessor-Based Regulating Apparatus, Voltage, Step Voltage Regulators Regulating Apparatus, Voltage, Induction Regulators Withdrawn Regulating Apparatus, Current - Reserved Regulating Apparatus, Load Tap-Changers Grounding Systems Ground-Fault Protection Systems, Low-Voltage Rotating Machinery, AC Induction Motors and Generators Rotating Machinery, Synchronous Motors and Generators Rotating Machinery, DC Motors and Generators Motor Control, Motor Starters, Low-Voltage Motor Control, Motor Starters, Medium-Voltage Motor Control, Motor Control Centers, Low-Voltage Motor Control, Motor Control Centers, Medium-Voltage Adjustable Speed Drive Systems Direct-Current Systems, Batteries, Flooded Lead-Acid Direct-Current Systems, Batteries, Vented Nickel-Cadmium Direct-Current Systems, Batteries, Valve-Regulated Lead-Acid Direct-Current Systems, Chargers Direct-Current Systems, Rectifiers - Reserved Surge Arresters, Low-Voltage Surge Arresters, Medium- and High-Voltage Capacitors and Reactors, Capacitors Capacitors and Reactors, Capacitor Control Devices - Reserved Capacitors and Reactors, Reactors, Shunt and Current-Limiting, Dry-Type Capacitors and Reactors, Reactors, Shunt and Current-Limiting, Liquid-Filled Outdoor Bus Structures Emergency Systems, Engine Generator Emergency Systems, Uninterruptible Power Systems Emergency Systems, Automatic Transfer Switches Communications - Reserved Automatic Circuit Reclosers and Line Sectionalizers, Automatic Circuit Reclosers, Oil/Vacuum Automatic Circuit Reclosers and Line Sectionalizers, Automatic Line Sectionalizers, Oil Fiber-Optic Cables SYSTEM FUNCTION TESTS THERMOGRAPHIC SURVEY ELECTROMAGNETIC FIELD TESTING CORONA STUDIES - Reserved...197
17 CONTENTS (continued) TABLES Insulation Resistance Test Values, Electrical Apparatus and Systems, Other Than Rotating Machinery Switchgear Withstand Test Voltages Recommended Dissipation Factor/Power Factor at 20 C; Liquid-Filled Transformers, Regulators, and Reactors, Acceptance Test Values Insulating Fluid Limits Test Limits for New Insulating Oil Received in New Equipment Test Limits for Silicone Insulating Liquid in New Transformers Typical Values for Less-Flammable Hydrocarbon Insulating Liquid Transformer Insulation Resistance, Acceptance Testing Medium-Voltage Cables, Acceptance Test Values DC Test Voltages AC Test Voltages Partial Discharge Requirements Very Low Frequency Testing Levels Inverse Time Trip Test at 300% of Rated Continuous Current, Molded-Case Circuit Breakers Instantaneous Trip Tolerances for Field Testing of Circuit Breakers Instrument Transformer Dielectric Tests, Field Acceptance Maximum Allowable Vibration Amplitude Insulation Resistance Test Values, Rotating Machinery, for One Minute at 40 C US Standard Fasteners, Bolt Torque Values for Electrical Connections Heat-Treated Steel - Cadmium or Zinc Plated Silicon Bronze Fasteners Aluminum Alloy Fasteners Stainless Steel Fasteners SF 6 Gas Tests Insulation Resistance Conversion Factors Test Temperatures to 20 C Test Temperatures to 40 C High-Potential Test Voltage, Automatic Circuit Reclosers High-Potential Test Voltage for Acceptance Test of Line Sectionalizers Dielectric Withstand Test Voltages, Metal-Enclosed Bus Thermographic Survey, Suggested Actions Based on Temperature Rise Dielectric Withstand Test Voltages, Electrical Apparatus Other than Inductive Equipment Rated Control Voltages and their Ranges for Circuit Breakers Circuit Breakers Solenoid-Operated Devices Accuracy of IEC Class TP Current Transformers Error Limit Minimum Radii for Power Cable, Single & Multiple Conductor Cables with Interlocked Armor, Smooth or Corrugated Aluminum Sheath or Lead Sheath...228
18 CONTENTS APPENDICES Appendix A - Definitions Appendix B - Reserved Appendix C - About the InterNational Electrical Testing Association Appendix D - Form for Comments Appendix E - Form for Proposals...237
19 1. GENERAL SCOPE 1. These specifications cover the suggested field tests and inspections that are available to assess the suitability for initial energization and final acceptance of electrical power equipment and systems. 2. The purpose of these specifications is to assure that tested electrical equipment and systems are operational, are within applicable standards and manufacturer's tolerances, and are installed in accordance with design specifications. 3. The work specified in these specifications may involve hazardous voltages, materials, operations, and equipment. These specifications do not purport to address all of the safety issues associated with their use. It is the responsibility of the user to review all applicable regulatory limitations prior to the use of these specifications Page 1
20 2. APPLICABLE REFERENCES 2.1 Codes, Standards, and Specifications All inspections and field tests shall be in accordance with the latest edition of the following codes, standards, and specifications except as provided otherwise herein. 1. American National Standards Institute ANSI 2. ASTM International - ASTM ASTM D92 ASTM D445 ASTM D664 ASTM D877 ASTM D923 ASTM D924 ASTM D971 ASTM D974 ASTM D1298 ASTM D1500 ASTM D1524 ASTM D1533 ASTM D1816 Standard Test Method for Flash and Fire Points by Cleveland Open Cup Tester Standard Test Method for Kinematic Viscosity of Transparent and Opaque Liquids (the Calculation of Dynamic Viscosity) Standard Test Method for Acid Number of Petroleum Products by Potentiometric Titration Standard Test Method for Dielectric Breakdown Voltage of Insulating Liquids using Disk Electrodes Standard Practices for Sampling Electrical Insulating Liquids Standard Test Method for Dissipation Factor (or Power Factor) and Relative Permittivity (Dielectric Constant) of Electrical Insulating Liquids Standard Test Method for Interfacial Tension of Oil against Water by the Ring Method Standard Test Method for Acid and Base Number by Color-Indicator Titration Standard Test Method for Density, Relative Density (Specific Gravity), or API Gravity of Crude Petroleum and Liquid Petroleum Products by Hydrometer Method Standard Test Method for ASTM Color of Petroleum Products (ASTM Color Scale) Standard Test Method for Visual Examination of Used Electrical Insulating Oils of Petroleum Origin in the Field Standard Test Methods for Water in Insulating Liquids by Coulometric Karl Fischer Titration Standard Test Method for Dielectric Breakdown Voltage of Insulating Oils of Petroleum Origin Using VDE Electrodes Page 2
21 2. APPLICABLE REFERENCES 2.1 Codes, Standards, and Specifications (continued) ASTM D2029 Standard Test Methods for Water Vapor Content of Electrical Insulating Gases by Measurement of Dew Point ASTM D2129 ASTM D2284 ASTM D2285 ASTM D2477 ASTM D2685 ASTM D2759 ASTM D3284 ASTM D3612 ASTM D3613 Standard Test Method for Color of Clear Electrical Insulating Liquids (Platinum-Cobalt Scale) Standard Test Method of Acidity of Sulfur Hexafluoride Standard Test Method for Interfacial Tension of Electrical Insulating Oils of Petroleum Origin against Water by the Drop-Weight Method Standard Test Method for Dielectric Breakdown Voltage and Dielectric Strength of Insulating Gases at Commercial Power Frequencies Standard Test Method for Air and Carbon Tetrafluoride in Sulfur Hexafluoride by Gas Chromatography Standard Practice for Sampling Gas from a Transformer under Positive Pressure Standard Test Method for Combustible Gases in the Gas Space of Electrical Apparatus Using Portable Meters Standard Test Method for Analysis of Gases Dissolved in Electrical Insulating Oil by Gas Chromatography Standard Practice for Sampling Electrical Insulating Oils for Gas Analysis and Determination of Water Content 3. Association of Edison Illuminating Companies - AEIC 4. Canadian Standards Association - CSA 5. Electrical Apparatus Service Association - EASA ANSI/EASA AR100 Recommended Practice for the Repair of Rotating Electrical Apparatus Page 3
22 2. APPLICABLE REFERENCES 2.1 Codes, Standards, and Specifications (continued) 6. Institute of Electrical and Electronic Engineers - IEEE ANSI/IEEE C2 ANSI/IEEE C37 Compilation ANSI/IEEE C57 Compilation ANSI/IEEE C62 Compilation ANSI/IEEE C93.1 ANSI/IEEE 43 ANSI/IEEE 48 IEEE 81 ANSI/IEEE 81.2 ANSI/IEEE 95 IEEE 100 IEEE 141 ANSI/IEEE 142 ANSI/IEEE 241 ANSI/IEEE 242 National Electrical Safety Code Guides and Standards for Circuit Breakers, Switchgear, Relays, Substations, and Fuses Distribution, Power, and Regulating Transformers Surge Protection Requirements for Power-Line Carrier Coupling Capacitors and Coupling Capacitor Voltage Transformers (CCVT) IEEE Recommended Practice for Testing Insulation Resistance of Rotating Machinery IEEE Standard Test Procedures and Requirements for Alternating- Current Cable Terminations 2.5 kv through 765 kv IEEE Guide for Measuring Earth Resistivity, Ground Impedance, and Earth Surface Potentials of a Ground System Part I: Normal Measurements IEEE Guide for Measurement of Impedance and Safety Characteristics of Large, Extended or Interconnected Grounding Systems IEEE Recommended Practice for Insulation Testing of Large AC Rotating Machinery with High Direct Voltage The Authoritative Dictionary of IEEE Standards Terms IEEE Recommended Practice for Electrical Power Distribution for Industrial Plants (IEEE Red Book) IEEE Recommended Practice for Grounding of Industrial and Commercial Power Systems (IEEE Green Book) IEEE Recommended Practice for Electric Power Systems in Commercial Buildings (Gray Book) IEEE Recommended Practice for Protection and Coordination of Industrial and Commercial Power Systems (Buff Book) Page 4
23 2. APPLICABLE REFERENCES 2.1 Codes, Standards, and Specifications (continued) IEEE 386 IEEE Standard for Separable Insulated Connectors System for Power Distribution Systems above 600 V ANSI/IEEE 399 ANSI/IEEE 400 ANSI/IEEE ANSI/IEEE ANSI/IEEE 446 ANSI/IEEE 450 ANSI/IEEE 493 ANSI/IEEE 519 ANSI/IEEE 602 ANSI/IEEE 637 IEEE 644 ANSI/IEEE 739 ANSI/IEEE 902 IEEE 1015 IEEE 1100 IEEE Recommended Practice for Power Systems Analysis (Brown Book) IEEE Guide for Field Testing and Evaluation of the Insulation of Shielded Power Cable Systems IEEE Guide for Field Testing of Shielded Power Cable Systems Using Very Low Frequency (VLF) IEEE Standard for High-Potential-Test Requirements for Excitation Systems for Synchronous Machines IEEE Recommended Practice for Emergency and Standby Power Systems for Industrial and Commercial Applications (Orange Book) IEEE Recommended Practice for Maintenance, Testing, and Replacement of Vented Lead-Acid Batteries for Stationary Applications IEEE Recommended Practice for the Design of Reliable Industrial and Commercial Power Systems (Gold Book) IEEE Recommended Practices and Requirements for Harmonic Control in Electrical Power Systems IEEE Recommended Practice for Electric Systems in Health Care Facilities (White Book) IEEE Guide for the Reclamation of Insulating Oil and Criteria for Its Use Procedures for Measurement of Power Frequency Electric and Magnetic Fields from AC Power Lines IEEE Recommended Practice for Energy Management in Commercial and Industrial Facilities (Bronze Book) IEEE Guide for Maintenance, Operation and Safety of Industrial and Commercial Power Systems (Yellow Book) IEEE Recommended Practice for Applying Low-Voltage Circuit Breakers Used in Industrial and Commercial Power Systems (Blue Book) IEEE Recommended Practice for Powering and Grounding Sensitive Electronic Equipment (Emerald Book) Page 5
24 2. APPLICABLE REFERENCES 2.1 Codes, Standards, and Specifications (continued) ANSI/IEEE 1106 IEEE Recommended Practice for Maintenance, Testing, and Replacement of Nickel-Cadmium Batteries for Stationary Applications ANSI/IEEE 1159 ANSI/IEEE 1188 IEEE 1584 IEEE Recommended Practice on Monitoring Electrical Power Quality IEEE Recommended Practice for Maintenance, Testing, and Replacement of Valve-Regulated Lead-Acid (VRLA) Batteries for Stationary Applications IEEE Guide for Arc-Flash Hazard Calculations 7. Insulated Cable Engineers Association ICEA ANSI/ICEA S /NEMA WC 74 ANSI/ICEA S ANSI/ICEA S kv Shielded Power Cable for Use in the Transmission and Distribution of Electric Energy Standard for Concentric Neutral Cables Rated 5,000-46,000 Volts Standard for Utility Shielded Power Cables Rated 5,000-46,000 Volts 8. InterNational Electrical Testing Association - NETA ANSI/NETA ETT ANSI/NETA MTS Standard for Certification of Electrical Testing Technicians Maintenance Testing Specifications for Electrical Power Equipment and Systems 9. National Electrical Manufacturers Association - NEMA NEMA AB4 ANSI/NEMA 84.1 NEMA MG1 Guidelines for Inspection and Preventive Maintenance of Molded-Case Circuit Breakers Used in Commercial and Industrial Applications Electrical Power Systems and Equipment Voltage Ratings (60 Hz) Motors and Generators 10. National Fire Protection Association - NFPA ANSI/NFPA 70 ANSI/NFPA 70B ANSI/NFPA 70E National Electrical Code Recommended Practice for Electric Equipment Maintenance Standard for Electrical Safety in the Workplace Page 6
25 2. APPLICABLE REFERENCES 2.1 Codes, Standards, and Specifications (continued) ANSI/NFPA 99 Health Care Facilities Code ANSI/NFPA 101 ANSI/NFPA 110 ANSI/NFPA 111 ANSI/NFPA 780 Life Safety Code Emergency and Standby Power Systems Standard on Stored Electrical Energy Emergency Systems and Standby Power Systems Installation of Lightning Protection Systems 11. Occupational Safety and Health Administration - OSHA 12. State and local codes and ordinances 13. Underwriters Laboratories, Inc. - UL Page 7
26 2. APPLICABLE REFERENCES 2.2 Other Publications Manufacturer s instruction manuals for the equipment to be tested. John L. Cadick, Electrical Safety Handbook, New York: McGraw Hill Megger, A Stitch in Time The Complete Guide to Electrical Insulation Testing Paul Gill, Electrical Power Equipment Maintenance and Testing, New York: Marcel Dekker, Inc. 2.3 Contact Information American National Standards Institute ANSI 25 West 43 rd Street 4 th Fl. New York, NY (212) ASTM International ASTM 100 Barr Harbor Drive W. Conshohocken, PA (610) Association of Edison Illuminating Companies AEIC 600 N. 18 th Street; PO Box 2641 Birmingham, AL (205) Canadian Standards Association CSA 178 Rexdale Boulevard Toronto, ON M9W 1R3 (416) Electrical Apparatus Service Association EASA 1331 Baur Boulevard St. Louis, MO (314) Institute of Electrical and Electronic Engineers IEEE PO Box 1331 Piscataway, NJ (732) Page 8
27 2. APPLICABLE REFERENCES 2.3 Contact Information (continued) Insulated Cable Engineers Association ICEA c/o Global Document Engineers 15 Inverness Way East Englewood, CO (303) International Electrotechnical Commission IEC Contact through American National Standards Institute InterNational Electrical Testing Association NETA 3050 Old Centre Avenue, Suite 102 Portage, MI (269) or (888) 300-NETA (6382) Marcel Dekker, Inc. PO Box 5005 Monticello, NY (800) The McGraw-Hill Companies P.O. Box Columbus, OH Phone: (877) Megger 4271 Bronze Way Dallas, TX (214) National Electrical Manufacturers Association NEMA 1300 N. 17 th St. Suite 1847 Rosslyn, VA (703) National Fire Protection Association NFPA 1 Battery March Park PO Box 901 Quincy, MA (617) Page 9
28 2. APPLICABLE REFERENCES 2.3 Contact Information (continued) Occupational Safety and Health Administration OSHA U.S. Department of Labor Occupational Safety and Health Administration Office of Public Affairs - Room N Constitution Avenue Washington, D.C (202) The Okonite Company 102 Hilltop Road Ramsey, New Jersey (201) Fax Underwriters Laboratories, Inc. UL 333 Pfingsten Road Northbrook, IL (847) Page 10
STANDARD FOR ACCEPTANCE TESTING SPECIFICATIONS for Electrical Power Equipment and Systems
AMERICAN NATIONAL STANDARD STANDARD FOR ACCEPTANCE TESTING SPECIFICATIONS for Electrical Power Equipment and Systems Secretariat InterNational Electrical Testing Association Approved by American National
APPENDIX B FREQUENCY OF MAINTENANCE TESTS
AMERICAN NATIONAL STANDARD APPENDIX B FREQUENCY OF MAINTENANCE TESTS an excerpt from the ANSI/ NETA Standard for Maintenance Testing Specifications for Electrical Power Equipment and Systems Secretariat
Schneider Electric Services: life-cycle solutions for electrical distribution equipment. Scopes of Work for Electrical Acceptance Testing
Scopes of Work for Electrical Acceptance Testing Schneider Electric Services: life-cycle solutions for electrical distribution equipment Make the most of your energy SM Scopes of Work for Electrical Acceptance
AC Electric Motors best practice
If you want to learn more about best practice machinery maintenance, or world class mechanical equipment maintenance and installation practices, follow the link to our Online Store and see the Training
SECTION 263235 STANDBY GENERATOR TESTING AND COMMISSIONING
SECTION 263235 STANDBY GENERATOR TESTING AND COMMISSIONING PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Standby generators. 2. Automatic Transfer Switches (ATS). 3. System start-up services. 4.
Unified requirements for systems with voltages above 1 kv up to 15 kv
(1991) (Rev.1 May 2001) (Rev.2 July 2003) (Rev.3 Feb 2015) Unified requirements for systems with voltages above 1 kv up to 15 kv 1. General 1.1 Field of application The following requirements apply to
GUIDELINES FOR WATER-DAMAGED ELECTRICAL EQUIPMENT
GUIDELINES FOR HANDLING WATER-DAMAGED ELECTRICAL EQUIPMENT NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION 1300 NORTH 17 TH STREET, SUITE 1752 ROSSLYN, VIRGINIA 22209 703 841-3200 703 841-5900 FAX WWW.NEMA.ORG
Emergency Power System Services Industrial UPS, Batteries, Chargers, Inverters and Static Switches
Emergency Power System Services Industrial UPS, Batteries, Chargers, Inverters and Static Switches Downtime Is Not An Option The industrial uninterruptible power supply (UPS) is the foundation of your
Evaluating Water-Damaged Electrical Equipment
Evaluating Water-Damaged Electrical Equipment 1 USE OF THIS PUBLICATION This publication provides information on how to evaluate electrical equipment that has been exposed to water through flooding, fire
Evaluating Fire- and Heat-Damaged Electrical Equipment
Evaluating Fire- and Heat-Damaged Electrical Equipment www.nema.org 1 USE OF THIS PUBLICATION This publication provides information on how to evaluate electrical equipment that has been exposed to heat
MV, HV AND EHV SWITCHGEAR TESTING & COMMISSIONING
Training Title MV, HV AND EHV SWITCHGEAR TESTING & COMMISSIONING Training Duration 5 days Training Date MV, HV and EHV Switchgear Testing & Commissioning 5 20 24 Apr $3,750 Dubai, UAE In any of the 5 star
SECTION 16999 ELECTRICAL ACCEPTANCE TESTS
SECTION 16999 ELECTRICAL ACCEPTANCE TESTS PART 1 2. AND 3. COMBINED 1.1 SUMMARY A. Description of Systems 1. Furnish all labor, materials, test equipment, and technical supervision to perform and record
Submit shop drawings for equipment provided under this section Shop drawings shall indicate:
Section 16435 - SWITCHBOARDS Introduction Part 1 - General Reference The work under this section is subject to requirements of the Contract Documents including the General Conditions, Supplementary Conditions,
Evaluating Water-Damaged Electrical Equipment
Evaluating Water-Damaged Electrical www.nema.org Evaluating Water-Damaged Electrical 1 USE OF THIS PUBLICATION This publication provides information on how to evaluate electrical equipment that has been
2a. IEM Indoor Metal Clad Medium Voltage Switchgear 15KV 16346-1. 2a. Section 16346 INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std.
2a. IEM Indoor Metal Clad Medium Voltage Switchgear 15KV 16346-1 2a. Section 16346 INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std. Relays) Part 1 General 1.1 CONDITIONS AND REQUIREMENTS: A. Refer to
Fusible Disconnect Switch
Circuit Breakers Circuit breakers are used in panelboards and switchboards to provide circuit protection and provide a means of energizing and de-energizing a circuit. Siemens Sentron molded case circuit
City Of Ottawa High Voltage Substation Inspection, Maintenance Rev 00 2015 July 17 and Testing, ROPEC Page 1
2015 July 17 and Testing, ROPEC Page 1 PART 1 GENERAL 1.1. Scope.1 Equipment replacement and testing for a 44 kv 4.16kV/600V substation: a. Replacement of Insulators as indicated on the drawings in Appendix
Evaluating Water-Damaged Electrical Equipment
Evaluating Water-Damaged Electrical Equipment 1 USE OF THIS PUBLICATION This publication provides information on how to evaluate electrical equipment that has been exposed to water through flooding, fire
This section applies to the design and installation of transformers.
ELECTRICAL: TRANSFORMERS BASIS OF DESIGN This section applies to the design and installation of transformers. Design Criteria 13.8-kV equipment shall be 15-kV class. Coordinate with short-circuit studies
Sample - No Commercial Use
COMPLETE REVISION October 2010 Electrical PIP ELSSG01 Design and Fabrication of Low-Voltage Metal-Enclosed AC Power Circuit Breaker Switchgear PURPOSE AND USE OF PROCESS INDUSTRY PRACTICES In an effort
ELECTRICAL ENGINEERING DESIGN CRITERIA APPENDIX F
ELECTRICAL ENGINEERING DESIGN CRITERIA APPENDIX F TABLE OF CONTENTS Appendix F - Electrical Engineering Design Criteria F.1 Introduction...F-1 F.2 Codes and Standards...F-1 F.3 Switchyard and Transformers...F-1
26 3213.13 Diesel Engine Driven Generators Page 1 of 6
Last Update: December 8, 2014 A. Description of System Consultant s Handbook Page 1 of 6 1. Provide a diesel engine driven electric generating unit, factory assembled, tested and certified to operate at
SALVAGING FLOOD DAMAGED ELECTRICAL EQUIPMENT
SALVAGING FLOOD DAMAGED ELECTRICAL EQUIPMENT Overview In all drying out of electrical windings, the regulation of temperature should be controlled carefully. Maximum drying temperatures on windings should
Specification Guide. for RVAC. Direct Replacement. AC Medium Voltage. Circuit Breakers
Specification Guide for RVAC Direct Replacement AC Medium Voltage Circuit Breakers Table of Contents 1.0 General Work Scope...3 2.0 Standards...3 3.0 Supplier Qualifications...4 4.0 Circuit Breaker Element
Switchgear and Metal-Enclosed Bus
Section 18 Switchgear and Metal-Enclosed Bus 180. SWITCHGEAR ASSEMBLIES 180A. General Requirements for All Switchgear. This rule covers general requirements for all switchgear. Examples of switchgear found
Section 9: Power Distribution Equipment Bill Brown, P.E., Square D Engineering Services
Section 9: Power Distribution Equipment Bill Brown, P.E., Square D Engineering Services Introduction Power Distribution Equipment is a term generally used to describe any apparatus used for the generation,
Predictive Maintenance
PART ONE of a predictive maintenance series Predictive Maintenance Overview Predictive maintenance programs come in all shapes and sizes, depending on a facility s size, equipment, regulations, and productivity
CIRCUIT BREAKER INTERRUPTING CAPACITY AND SHORT-TIME CURRENT RATINGS
CIRCUIT BREAKER INTERRUPTING CAPACITY AND SHORT-TIME CURRENT RATINGS David D. Roybal, P.E. Senior Member, IEEE Eaton Electrical 3697 Mount Diablo Boulevard Lafayette, CA 94549 Abstract Low-voltage circuit
D. Infrared scanning reports with pictures printed in a final report with any deficiencies and actions taken to rectify.
SECTION 263354 STATIC UPS TESTING AND COMMISSIONING PART 1 - GENERAL 1.1 SUMMARY A. Section Includes 1. System start-up services. 2. Battery charging. 3. Load bank testing. 4. Battery load testing. 5.
Secondary Unit Substations
14 SWITCHGEAR Secondary Unit Substations Overview Siemens offers a wide variety of unit substation designs to meet customer requirements. A unit substation consists of one or more transformers mechanically
Primary and Secondary Electrical Distribution Systems
Primary and Secondary Electrical Distribution Systems Critical Facilities Round Table 12th Quarterly Membership Meeting June 2, 2006 David D. Roybal. P.E. Eaton Electrical Cutler-Hammer Products Utility
SWITCHGEAR Section 16. SECTION INCLUDES This Section includes service and distribution switchboards rated 600 V and less.
PART 1 - GENERAL SECTION INCLUDES This Section includes service and distribution switchboards rated 600 V and less. RELATED SECTIONS Division 16 Section "Basic Electrical Materials and Methods" for general
ELECTRICAL INSULATION TESTING OF HV EQUIPMENT UP TO 33kV
1. SCOPE This document details PowerSystems requirements for electrical testing of HV Equipment up to and including 33kV. 2. ISSUE RECORD This is a Reference document. The current version of Controlled
INTERNATIONAL STANDARD
INTERNATIONAL STANDARD IEC 60076-11 First edition 2004-05 Power transformers Part 11: Dry-type transformers This English-language version is derived from the original bilingual publication by leaving out
Electrical Predictive and Preventative Maintenance
Electrical Predictive and Preventative Maintenance Electrical and mechanical equipment is subject to failure at the worst possible time for no apparent reason. - Mose Ramieh III There are two types
SECTION 26 29 23 VARIABLE FREQUENCY DRIVES
SECTION 26 29 23 VARIABLE FREQUENCY DRIVES PART 1 GENERAL 1.01 SCOPE A. Furnish and install individual freestanding variable frequency AC drives (VFD) as shown on the Drawings and specified herein. 1.02
Electrical Distribution Services for Mining and Metals Industries
Electrical Distribution Services for Mining and Metals Industries Solutions to help maximize plant reliability and ensure personnel safety Make the most of your energy SM Electrical Systems are Serious
American National Standard For Electrical Rigid Steel Conduit (ERSC)
Revision of ANSI C80.1-1994 American National Standard For Electrical Rigid Steel Conduit (ERSC) Secretariat: Approved August 18, 2005 American National Standards Institute, Inc. NOTICE AND DISCLAIMER
METAL-CLAD AND METAL-ENCLOSED SWITCHGEAR 3.6KV~40.5KV. tgood.com. Energy. Fast.
METAL-CLAD AND METAL-ENCLOSED SWITCHGEAR 3.6KV~40.5KV tgood.com Energy. Fast. TGOOD produces over 5000 switchgear units annually for projects around the globe PRODUCT OVERVIEW Integral substation component
CAPACITOR BANK TESTING SWP
1. PURPOSE AND SCOPE The purpose of this Standard Work Practice (SWP) is to standardise and prescribe the method for testing Capacitor Banks including capacitors, tuning reactors and inrush limiting reactors.
Short Circuit Current Calculations
Introduction Several sections of the National Electrical Code relate to proper overcurrent protection. Safe and reliable application of overcurrent protective devices based on these sections mandate that
SEWER CHEWER Wastewater / Sludge Grinder Submersible Gearmotor
INSTALLATION, OPERATION AND MAINTENANCE MANUAL For SEWER CHEWER Wastewater / Sludge Grinder Submersible Gearmotor Yeomans Chicago Corporation 3905 Enterprise Court P.O. Box 6620 Aurora, IL 60598-0620 Phone:
MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV.00 2012.4
CE - BF - C - en - REV.00 2012.4 APPLICATION CE-BF Switchbords up to 40.5 kv are designed for use in public and industrial distribution system up to 40,5KV for the operation and protection of lines, transformers,
American National Standard for Electric Lamps Specifications for Performance of Self-ballasted Compact Fluorescent Lamps
Page 1 C78.5-2003 (R2008, R2015) American National Standard for Electric Lamps Specifications for Performance of Self-ballasted Compact Fluorescent Lamps Secretariat: National Electrical Manufacturers
Choosing the Best Solution for Reducing Arc Energy
CONVENTION SESSION HANDOUT Choosing the Best Solution for Reducing Arc Energy Terry L. Schiazza, Business Development Manager Square D / Schneider Electric SESSION #11 Independent Electrical Contractors
A Practical Guide to Dielectric Testing
Chroma Systems Solutions, Inc. A Practical Guide to Dielectric Testing 19032 Series Electrical Safety Analyzer & 19050 Series Hipot Tester AC/DC/IR/SCAN Keywords: Dielectric tests, insulation resistance
3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & 8 3. 4.0 Instructions For Installation, Operation & Maintenance
SPECIFICATION FOR LOW VOLTAGE SWITCHBOARD SEN I N D E X Description 10 STANDARD TECHNICAL REQUIREMENTS 11 Standards 12 General Operating Conditions 13 General Description Of Switchboard 131 Structure 132
NFPA 70E 2012 Rolls Out New Electrical Safety Requirements Affecting Data Centers
NFPA 70E 2012 Rolls Out New Electrical Safety Requirements Affecting Data Centers A market position paper from the experts in Business-Critical Continuity TM Executive Summary Electrocutions are the fourth
The following components are common to most cubicles; this example is an ABB HK cubicle.
4.0 CIRCUIT BREAKER CUBICLE Learning Objectives The circuit breaker cubicle is the component of the switchgear that holds the circuit breaker, and the controls and cabling for the distribution system.
DRAFT REGULATORY GUIDE DG-1154 (Proposed Revision 2 of Regulatory Guide 1.128, dated October 1978)
U.S. NUCLEAR REGULATORY COMMISSION October 2006 OFFICE OF NUCLEAR REGULATORY RESEARCH Division 1 DRAFT REGULATORY GUIDE Contact: W.S. Raughley (301) 415-7577 DRAFT REGULATORY GUIDE DG-1154 (Proposed Revision
EVANS ENTErprises, Inc.
EVANS ENTErprises, Inc. Since 1954 THE LEADER IN ELECTRO-MECHANICAL SALES, SERVICE AND INTERGRATION Our Mission Our purpose at Evans Enterprises is to serve customers by providing increased value of product
electrical services WWW.AU.SGS.COM/INDUSTRIAL
electrical services WWW.AU.SGS.COM/INDUSTRIAL OUR PROFILE SGS offers a full range of electrical engineering services covering the commissioning test of new plant as well as the maintenance and continual
SYNCHRONOUS MACHINE TESTING WITH MOTOR CIRCUIT ANALYSIS INSTRUMENTATION
SYNCHRONOUS MACHINE TESTING WITH MOTOR CIRCUIT ANALYSIS INSTRUMENTATION Introduction Howard W. Penrose, Ph.D., CMRP Vice President, Engineering and Reliability Services Dreisilker Electric Motors, Inc.
ELECTRICIAN TRADE REGULATION
Province of Alberta APPRENTICESHIP AND INDUSTRY TRAINING ACT ELECTRICIAN TRADE REGULATION Alberta Regulation 274/2000 With amendments up to and including Alberta Regulation 122/2014 Office Consolidation
Dielectric Withstand Testing in a Production Environment
Dielectric Withstand Testing in a Production Environment Performing a routine product safety test should not in itself represent a shock hazard to the operator who is conducting the test, yet anytime you
Integrating SPDs in Switchgear & Switchboards Causes More Problems than it Solves
Integrating SPDs in Switchgear & Switchboards Causes More Problems than it Solves White Paper July 2010 Integrating surge protective devices (SPD) into distribution equipment (i.e. switchgear, switchboards,
Enhance Power Equipment Reliability with Predictive Maintenance Technologies
Enhance Power Equipment Reliability with Predictive Maintenance Technologies November 2012/1910DB1208 by S. Frank Waterer, Electrical Engineerinig, Fellow Schneider Electric USA, Inc. Make the most of
www.klmtechgroup.com TABLE OF CONTENT
Page : 1 of 13 Project Engineering Standard www.klmtechgroup.com KLM Technology #03-12 Block Aronia, Jalan Sri Perkasa 2 Taman Tampoi Utama 81200 Johor Bahru Malaysia ELECTIRAL GROUNDING TABLE OF CONTENT
The table below lists the symbols used on the Clamp and/or in this manual. Important Information. See manual.
i800 AC Current Clamp Instruction Sheet Introduction The i800 AC Current Clamp, the Clamp, has been designed for use with multimeters, recorders, power analyzers, safety testers, etc., for accurate non-intrusive
ABB ! CAUTION. Type COQ Negative Sequence Generator Relay. (50/60 Hertz) 41-161J. Instruction Leaflet
ABB Instruction Leaflet 41-161J Effective: May 1997 Supersedes I.L. 41-161H Dated July 1984 ( ) Denotes Change Since Previous Issue Type COQ Negative Sequence Generator Relay (50/60 Hertz)! CAUTION Before
Pressure monitoring equipment for oil-sf 6. bushings, type GOEK
Pressure monitoring equipment for oil-sf 6 bushings, type GOEK Installation and maintenance guide 5693 827-6 en, Rev. 3, 2002-01-30 This document must not be copied without our written permission, and
Motor Protection Voltage Unbalance and Single-Phasing
Motor Protection Voltage Unbalance and Single-Phasing Cooper Bussmann contributes the following information, which is an excerpt from their 190-page handbook SPD Selecting Protective Devices Based on the
ANCILLARY EQUIPMENT AND ELECTRICAL EQUIPMENT Power Supply Systems and Electrical Equipment for Desalination Plants - Y.M. Hamud and A.H.
POWER SUPPLY SYSTEMS AND ELECTRICAL EQUIPMENT FOR DESALINATION PLANTS Y.M. Hamud and A.H. Anwar Abu Dhabi Water and Electricity Authority, Abu Dhabi, UAE Keywords : Electrical System, Network for Desalination,
MEDIUM VOLTAGE METAL CLAD SWITCHGEAR
MEDIUM VOLTAGE METAL CLAD SWITCHGEAR PART 1 - GENERAL 1.1 DESCRIPTION This section specifies the furnishing, installation, connection and testing of the medium voltage switchgear. 1.2 SWITCHGEAR FEATURES
Product Description Full Voltage Starting Electric Fire Pump Controllers FTA1000
Product Description Full Voltage Starting Electric Fire Pump Controllers FTA1000 Description Firetrol FTA1000 Full Voltage Fire Pump Controllers are intended for use with electric motor driven fi re pumps
Power Plant Electrical Distribution Systems
PDH Course E184 Power Plant Electrical Distribution Systems Gary W Castleberry, PE 2008 PDH Center 2410 Dakota Lakes Drive Herndon, VA 20171-2995 Phone: 703-478-6833 Fax: 703-481-9535 www.pdhcenter.com
www.klmtechgroup.com TABLE OF CONTENT
Page : 1 of 29 Project Engineering Standard www.klmtechgroup.com KLM Technology #03-12 Block Aronia, Jalan Sri Perkasa 2 Taman Tampoi Utama 81200 Johor Bahru Malaysia TABLE OF CONTENT SCOPE 2 REFERENCES
The easy way to build switchgear and controlgear assemblies in compliance with the regulations
The easy way to build switchgear and controlgear assemblies in compliance with the regulations A guide for partially type-tested switchgear and controlgear assemblies in compliance with EN 60 439 What
21 st Century Facilities
Electrical Testing 21 st Century Facilities Facility Owners face tough challenges 24 X 7 reliability needed Non linear loads cause harmonics VFD Computers Switching transients disrupt operations Less customer
SWITCHGEAR SOLUTIONS FOR MISSION CRITICAL APPLICATIONS. Presented by SAI Advanced Power Solutions
SWITCHGEAR SOLUTIONS FOR MISSION CRITICAL APPLICATIONS POWER DISTRIBUTION RACKS IN A MISSION CRITICAL SYSTEM MODULES IN A MISSION CRITICAL SYSTEM UPS Convertor Main Inverter Load Battery BPC UPS & BATTERY
World Leader in HV Testing Technology
World Leader in HV Testing Technology Cable Fault Locators w/tdr Oil/Fluid Dielectric Testers Very Low Frequency AC Technology W/TD & PD Diagnostics Portable AC Hipots ---------------------------------
Eaton s Electrical Services & Systems. Technical Training Safety Training
Eaton s Electrical Services & Systems Technical Training Safety Training 2 EATON CORPORATION Eaton s Electrical Services & Systems Technical Training Safety Training Eaton conducts technical training and
SUGGESTED SPECIFICATION for Series 185 Service Entrance Rated Automatic Transfer Switches
SUGGESTED SPECIFICATION for Series 185 Service Entrance Rated Automatic Transfer Switches PART 1 GENERAL 1.01 Scope Optional Standby Power Generator Systems A. Furnish and install automatic transfer switches
Understanding Insulation Resistance Testing
Understanding Insulation Resistance Testing Why have an insulation testing program? A regular program of testing insulation resistance is strongly recommended to prevent electrical shocks, assure safety
Single Phase Soft Starter
Single Phase Soft Starter Installation & Operating Manual 6/02 Table of Contents Section 1 General Information................................................... 1 1 General Description................................................
Atlanta Chapter IEEE Industry Applications Society
Atlanta Chapter IEEE Industry Applications Society Electrical Equipment Room Design Considerations presented at the Sheraton Buckhead Hotel Atlanta, Georgia November 20, 2006 Outline 1. Definitions 2.
Extend the Life of Existing Switchgear
Extend the Life of Existing Switchgear January 2011/1910DB1002 by Hal Theobald, Product Manager Schneider Electric USA, Inc. Make the most of your energy SM Summary Introduction... p 3 Maintenance Requirements...
PROGRAM CRITERIA FOR ELECTRICAL ENGINEERING TECHNOLOGY
PROGRAM CRITERIA FOR ELECTRICAL ENGINEERING TECHNOLOGY Scope These program criteria apply to programs having titles involving Electrical Engineering Technology including: electrical engineering, electrical
Electrical Shore Connections / Cold Ironing
STANDARD FOR CERTIFICATION No. 2.25 Electrical Shore Connections / Cold Ironing JULY 2014 The electronic pdf version of this document found through http://www.dnv.com is the officially binding version
SURGE PROTECTIVE DEVICES (SPDs) LOW VOLTAGE AC INTEGRATED SURGE PROTECTION FOR ELECTRICAL DISTRIBUTION SYSTEMS SECTION 16671A SECTION 16671A
SURGE PROTECTIVE DEVICES (SPDs) INTEGRATED UNITS LOW VOLTAGE AC SURGE PROTECTION FOR ELECTRICAL DISTRIBUTION SYSTEMS PART 1 GENERAL 01 02 03 SCOPE The Contractor shall furnish and install the Surge Protective
Standard for an Electrical Preventive Maintenance (EPM) Program
Recommended Maintenance Practices for Electrical Distribution System Equipment Hartford Steam Boiler One State Street P.O. Box 5024 Hartford, CT 06102-5024 Tel: (800) 472-1866 www.hsb.com April 2013 Introduction
Interconnection Application For Residential and Commercial Power Systems 10 kw or Smaller
Interconnection Application For Residential and Commercial Power Systems 10 kw or Smaller A fee of $0.00 must accompany this application Date: Section 1: Customer Information Section 2: Engineering firm
HIGH SPEED COMMUNICATIONS PLENUM CABLE CATEGORY 5e CMP FEP JACKETED, PVC-FREE UNSHIELDED TWISTED PAIR (UTP)
Cable Specification Category 5e CMP HIGH SPEED COMMUNICATIONS PLENUM CABLE CATEGORY 5e CMP FEP JACKETED, PVC-FREE UNSHIELDED TWISTED PAIR (UTP) This cable specification complies with the electrical transmission
American National Standard. For Insulators. Wet Process Porcelain and Toughened Glass Suspension Type ANSI/NEMA C29.2-2012
ANSI/NEMA C29.2-2012 American National Standard For Insulators Wet Process Porcelain and Toughened Glass Suspension Type Secretariat: National Electrical Manufacturers Association Approved: October 2012
ANSI/IEC 60529-2004. Degrees of Protection Provided by Enclosures (IP Code) (identical national adoption)
ANSI Approval Date November 3, 2004 ANSI/IEC 60529-2004 Degrees of Protection Provided by Enclosures (IP Code) (identical national adoption) Published by: National Electrical Manufacturers Association
INTERNATIONAL STANDARD
IEC 61892-7 INTERNATIONAL STANDARD Edition 2.0 2007-11 Mobile and fixed offshore units Electrical installations Part 7: Hazardous areas INTERNATIONAL ELECTROTECHNICAL COMMISSION PRICE CODE XA ICS 47.020.60
Trade of Electrician. Three-phase Distribution Boards And Socket Circuits
Trade of Electrician Standards Based Apprenticeship Three-phase Distribution Boards And Socket Circuits Phase 2 Module No. 2.3 Unit No. 2.3.2 COURSE NOTES Created by Charlie Walsh - Athlone TC Revision
SECTION 26 09 13 - POWER MONITOR FOR ELECTRICAL, STEAM CONDENSATE, AND WATER PART I - GENERAL
SECTION 26 09 13 - POWER MONITOR FOR ELECTRICAL, STEAM CONDENSATE, AND WATER PART I - GENERAL 1.1 SUMMARY A. This section describes the requirements for the installation of Power Monitors and associated
American National Standard For Electric Power Systems and Equipment Voltage Ratings (60 Hertz)
Revision of ANSI C84.1-2006 American National Standard For Electric Power Systems and Equipment Voltage Ratings (60 Hertz) Secretariat: National Electrical Manufacturers Association Approved December 6,
COMPARISON OF ANSI/IEEE AND IEC REQUIREMENTS FOR LOW- VOLTAGE SWITCHGEAR
COMPARISON OF ANSI/IEEE AND IEC REQUIREMENTS FOR LOW- VOLTAGE SWITCHGEAR Copyright Material IEEE Paper No. PCIC 2003-13 Eddie Wilkie Eaton Cutler-Hammer 3990 Old Tasso Road NE Cleveland, TN 37312 USA Abstract
FFI. Advances in Medium and Low Voltage Power Distribution ESS Metron Expo and Technical Seminars. Presented By: Greg Pelster & Robert Schmid
Advances in Medium and Low Voltage Power Distribution ESS Metron Expo and Technical Seminars Presented By: Greg Pelster & Robert Schmid FFI Ferrie, Franzmann Industries LOW VOLTAGE SWITCHGEAR & LOW VOLTAGE
Power-factor testing of rotating machinery is another valuable test
Feature Power-Factor Testing of Stator Winding Insulation: Understanding the Test Technique and Interpretation of Results Power-factor testing of rotating machinery is another valuable test technique providing
7.2KV SL400 Withdrawable Vacuum Contactor-Fuse Combination Units
Automotive Powering business worldwide Aerospace Eaton delivers the hundreds of power distribution products that are answering the demands of today s fast changing world. We help our customers worldwide
Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw
4 937 DESIO Current valve for AC 24 V pulse/pause control of electrical loads up to 30 kw SEA45.1 Use The current valve is used for the control of electric heating elements in heating, ventilation and
Introduction. Harmonics and IEEE 519 Page 1 of 19
Introduction In an ideal power system, the voltage supplied to customer equipment, and the resulting load current are perfect sine waves. In practice, however, conditions are never ideal, so these waveforms
Selecting Current Transformers Part 1 By Darrell G. Broussard, P.E.
By Darrell G. Broussard, P.E. Introduction: As engineers, we are aware that electrical power systems have grown. How much have they grown? When was the last time you specified a 2400-volt system, a 4160-volt
National Craft Assessment and Certification Program S P E C I F I C A T I O N S
National Craft Assessment and Certification Program S P E C I F I C A T I O N S INDUSTRIAL ELECTRICIAN V4 ELEC26_O4 Released September 2013 Focus Statement An Industrial Electrician must be able to interpret
American National Standard. Physical Aspects of Watthour Meters Safety Standard. ANSI C12.10-2011 Revision of ANSI C12.10-2004
Revision of ANSI C12.10-2004 American National Standard Physical Aspects of Watthour Meters Safety Standard Secretariat: National Electrical Manufacturers Association Approved June 28, 2011 American National
Engineering innovation
Eaton's Electrical Engineering Services & Systems Solutions Focus Seamless Solutions for Reliable, Efficient and Safe Power Systems Engineering innovation Progressive solutions for today s power systems