1 INSTALLATION, OPERATION AND MAINTENANCE MANUAL For SEWER CHEWER Wastewater / Sludge Grinder Submersible Gearmotor Yeomans Chicago Corporation 3905 Enterprise Court P.O. Box 6620 Aurora, IL Phone: Fax: (THIS INSTRUCTION TO BE USED WITH GRINDER MANUAL 7671 AND DIGITAL CONTROLLER MANUAL 820) Important: Save this Manual for future reference. 840 Sub Gearmotor Swr Chwr.doc 8/11/2010 1
2 Table of Contents Title Page A. GENERAL DESCRIPTION AND INFORMATION 1. Acceptance of Shipment... 3 B. SAFETY PRECAUTIONS... 3 C. GENERAL NOTES 1. Long Term Storage Instructions Installation Notes... 4 D. START-UP... 5 E. MAINTENANCE... 5 F. THERMAL PROTECTION SYSTEM 1. Operation... 6 G. DISASSEMBLY INSTRUCTIONS 1. For Electrical Repairs For Mechanical Repairs... 7 H. REASSEMBLY INSTRUCTIONS... 8 I. ELECTRICAL DATA... 8 J. GEARMOTOR CROSS-SECTION DRAWING... 9 Motor Nameplate 840 Sub Gearmotor Swr Chwr.doc 8/11/2010 2
3 A. GENERAL DESCRIPTION AND INFORMATION 1. Acceptance of Shipment Thoroughly inspect this equipment before accepting shipment from the transportation company. If any of the goods called for in the bill of lading or express receipt are damaged or the quantity is short, do not accept them until the freight or express agent makes an appropriate notation on your freight bill or express receipt. If any concealed loss or damage is discovered later, notify your freight or express agent at once and request him to make an inspection. We will assist you in collecting claims for loss or damage in shipment; however, this willingness on our part does not remove the transportation company s responsibility in reimbursing you for collection of claims or replacement of material. Claims for loss or damage in shipment must not be deducted from the Yeomans Chicago Corporation invoice, nor should payment of the Yeomans Chicago Corporation invoice be withheld awaiting adjustment of such claims, as the carrier guarantees safe delivery. If considerable damage has been incurred and the situation is urgent, contact the nearest Yeomans Chicago Corporation Representative or the factory for assistance. Please keep a written record of all such communications. B. SAFETY PRECAUTIONS IMPORTANT THOROUGHLY READ ALL INSTRUCTIONS BEFORE SERVICING YEOMANS CHICAGO CORPORATION GEARMOTORS. Yeomans Chicago Corporation cannot be responsible for any damage resulting from failure to comply with these instructions. This gearmotor is not to be operated at conditions, nor with liquids other than those stated in the original order acknowledgment or Sewer Chewer Typical Specifications without written permission from Yeomans Chicago Corporation. Keep this manual handy for ready reference. Extra sets of gearmotor nameplates are furnished for future reference. These should be retained in a safe place. Information shown on the nameplate is required for ordering replacement parts. CAUTION Surface temperature of the motor enclosure may reach temperatures that can cause discomfort or injury to personnel making accidental contact. The user should provide protection against accidental contact with hot surfaces. WARNING MOTOR MAY CONTAIN GAS UNDER PRESSURE DUE TO HIGH TEMPERATURES FROM OPERATION. DISASSEMBLY MAY CAUSE BODILY INJURY. CARE MUST BE TAKEN IN DISASSEMBLY. CONTACT YEOMANS CHICAGO CORPORATION FOR ASSISTANCE. DANGER DISCONNECT POWER TO GRINDER CONTROLLER AND USE PROPER LOCKOUT DEVICE BEFORE MAINTENANCE OR OPERATOR ADJUSTMENT TO MACHINE. DISCONNECT MAIN MACHINE WINDINGS AND ALL ACCESSORY DEVICES FROM THE POWER SOURCE BEFORE DISASSEMBLY OF GEARMOTOR. INSTALL ALL GUARDS PRIOR TO ENERGIZING UNIT. 840 Sub Gearmotor Swr Chwr.doc 8/11/2010 3
4 C. GENERAL NOTES 1) Motor - YEOMANS CHICAGO CORPORATION Submersible gearmotors are T.E.N.V., of an explosion-proof design. To insure the integrity of sealing surfaces and explosion-proof fits when servicing these motors, all parts should be handled with utmost care. 2) Wound Stators - YEOMANS CHICAGO CORPORATION Submersible gearmotors have stator insulation systems specifically designed for the temperature and electrical ratings involved. If motor failure is analyzed to encompass a winding failure, it is required that a replacement wound stator be ordered from YEOMANS CHICAGO CORPORATION. 3) Epoxy Seal Cap Assembly - The leads have been specially encapsulated to insure integrity of the motor. The cap assembly can be removed from the motor in order to perform normal repairs. Should the power cables or cap assembly be damaged or the integrity of the encapsulation be in question, it is required that a replacement seal cap assembly be ordered from YEOMANS CHICAGO CORPORATION. 4) Hardware - All hardware is stainless steel, and if necessary, should be replaced with the same type. 1. Long Term Storage Instructions The equipment is shipped from the factory with adequate protection for transportation in covered trucks, and for indoor storage at the job site for a limited time between receipt and installation. If the equipment is not put into immediate use, it should be stored in a cool, clean, and dry indoor location. To help prevent rusting, any paint scratches or chips incurred during handling should be touched up prior to storage. Store in the vertical position. Electrical cables must be properly supported and protected from moisture. Exposed pipe flange connections should also be covered. 2. Installation Notes Maximum submergence of gearmotor is not to exceed 20 feet in depth. Thermal Protectors (Leads marked P1 and P2) must be connected. Leads marked W1 and W2 in the control cable are not used. (The unused wires are colors Red and Orange) Check power supply against final nameplate connection voltage. When the submersible gearmotor leaves the factory it is ready for installation, however, during shipping and handling, fasteners may loosen. Verify tightness before installation. No further adjusting, venting or lubricating is required. The motor will operate successfully when the following conditions are met: Voltage variation: 10% above or below nameplate data. Frequency variation: 5% above or below nameplate data. Voltage unbalance: 1% maximum between any two (2) incoming power legs. Performance within these ranges will not necessarily be the same as the established performance at exact rated voltage and frequency. The submersible gearmotor will operate in either direction of rotation. To reverse direction of a 3-phase motor, interchange any two motor leads at the starter. 840 Sub Gearmotor Swr Chwr.doc 8/11/2010 4
5 A lifting bail or lifting eyebolts are supplied for the purpose of installation and servicing. DO NOT USE MOTOR CABLES FOR LIFTING WHICH MAY RESULT IN PERMANENT DAMAGE TO THE CAP AND CABLE ASSEMBLY. Normal care should be exercised to prevent mechanical damage to the seal, the frame, and the insulated cable. CAUTION Control leads should not be installed in the same conduit as power leads. Additionally, junction boxes installed inside wet wells are subject to moisture and condensation. NEMA 4, 6 or 7 junction boxes should be used for this application. D. START-UP On initial start-up, prior to installation, the grinder should be rechecked for proper rotation. An arrow on the outside of the grinder housing shows the proper direction of rotation. Refer to Sewer Chewer Manual for procedure. The unit is designed to protect all power connections against moisture. All Yeomans Chicago Corporation submersible gearmotors have a lead connection chamber. Three phase, dual voltage motors have 9 stator leads. In addition, all submersible gearmotors have 2 thermal protector leads in this chamber. Leads are tagged for easy identification. Appropriate connection diagram can be found in the controller manual lead dual-voltage motors can be connected for either high or low voltages. (Some motor ratings are built as single voltage units and as such are not re-connectable.) The epoxy cap assembly is supplied with terminals for connecting power leads, control leads, and ground. The leads are brought through an epoxy sealed cap providing a mechanically strong, water tight, non-wicking seal. The cap and cable assembly is available from YEOMANS CHICAGO CORPORATION as a replacement part. When replacing the epoxy seal cap assembly, care should be taken not to nick or damage the O ring seal. Replace any damaged or nicked O rings. WHEN A REPLACEMENT CAP ASSEMBLY IS REQUIRED, BE SURE TO ORDER FROM YEOMANS CHICAGO CORPORATION USING GRINDER AND/OR MOTOR NAMEPLATE IDENTIFICATION NUMBERS. E. MAINTENANCE The motor and gear reducer are supplied with sufficient lubrication for five years of continuous use, and no routine maintenance is required during this time. 840 Sub Gearmotor Swr Chwr.doc 8/11/2010 5
6 F. THERMAL PROTECTION SYSTEM WARNING MOTOR CONTROLLER HAS AUTOMATIC OVERLOAD RESET. DISCONNECT ALL POWER LEADS TO MOTOR WHEN PERFORMING ANY WORK ON MOTOR OR GRINDER. FAILURE TO PROPERLY CONNECT OR UTILIZE THIS SYSTEM ON YOUR SUBMERSIBLE MOTOR OR ANY OTHER MOTOR FURNISHED WITH THERMAL PROTECTION VOIDS THE MOTOR WARRANTY. If current through the thermostats will exceed the values listed in Table 1, an intermediate control circuit relay must be used to reduce the current or the thermostats will not work properly. TABLE 1 Alternating Current Volts Continuous Amps Inrush Amps Operation For proper operation, the thermostats located within the motor must be connected to the SEWER CHEWER control panel. Your submersible motor control cable is furnished with four leads: Thermostat leads are P1 (Black) and P2 (White). Leads W1 (Red) and W2 (Orange) are not used in this application and should be capped. For all other motors, refer to the motor manufacturer s wiring diagram, usually located inside motor conduit box. Connect control cable wire P1 to terminal block #50 and wire P2 to terminal block #65 located in control panel (refer to electrical schematic in manual 820). If the grinder is running and the temperature of the motor exceeds the thermostat setting, relay will de-energize. This will de-energize the motor contactors not allowing the grinder motor to run. After five seconds, the operator interface display (OID) will flash an alarm message on the screen and the alarm horn will sound every 10 seconds. This will continue until the alarm is cleared (the motor temperature cools). Once the alarm is cleared, the SEWER CHEWER will automatically begin a restart sequence with a continuous horn for 10 seconds followed by a beeping horn for 5 seconds to provide a warning that the grinder will automatically restart. Upon completion of the horn sequence the controller resumes the exact grinder status as before. 840 Sub Gearmotor Swr Chwr.doc 8/11/2010 6
7 G. DISASSEMBLY INSTRUCTIONS WARNING MOTOR MAY CONTAIN GAS UNDER PRESSURE DUE TO HIGH TEMPERATURES FROM ABNORMAL OPERATION. DISASSEMBLY MAY CAUSE BODILY INJURY. 1. For Electrical Repairs Electrical repairs such as stator repair and/or replacement, or servicing of thermal protectors may be accomplished without disturbing the rotating assembly (i.e. rotor, thrust bearing housing, lower seal housing). Refer to Cross Section Drawing (Page 9) 1) Remove cap screws securing epoxy seal cap (9A). 2) Disconnect all leads and grounding wire. Remove epoxy seal cap assembly. 3) Remove bolts securing thrust bearing housing (5) to stator housing (7). Using top lifting bail (29), lift stator assembly. 4) Remove lifting bail (29) and lifting bail hardware, along with all hardware connecting the radial bearing housing (8) to the stator housing (7). NOTE: Pay particular attention to the location of lifting bail so that it is reassembled in the same position. 5) Remove radial bearing housing (8) if necessary. 2. For Mechanical Repairs This unit is not field serviceable for mechanical repairs and must be returned to the factory for the following: 1. Bearing replacement. 2. Shaft and rotor replacement. 3. Seal replacement. 4. Cycloidal gear repairs. 840 Sub Gearmotor Swr Chwr.doc 8/11/2010 7
8 H. REASSEMBLY INSTRUCTIONS Place O rings on register fits. Lightly coat all fits with a suitable lubricant. Alternately, grease may be substituted (not excessive). Lower stator housing (7) over rotating assembly. Bolt stator housing (7) to thrust bearing housing (5) with cap screws, making sure the O ring is not damaged and is properly seated. Pre-pack radial bearing (11) 3/4 full with #2 lithium based grease unless it is a sealed type bearing which requires no additional lubrication). Do not over-grease. Assemble radial bearing housing (8) to stator housing (7) by pulling all lead wires through one of the cored openings in bearing housing (8). Make sure O ring is seated properly before tightening all hardware previously removed. Replace lifting bail (29) to original position and secure with fastening hardware. Cable Cap Assembly-- A) Place O ring on radial bearing housing (8) and lightly coat with grease (not excessive). B) Reconnect power and control wires using applicable connection diagram shown below. C) Secure epoxy seal cap (9A) to radial bearing housing (8) using screws, making sure O ring is properly seated. LEAD COLOR CODING BLACK WHITE RED GREEN ORANGE POLYPHASE POWER CABLE T1 T2 T3 GROUND CONTROL CABLE P1 P Note: The Red and Orange control wires are unused in this application. I. ELECTRICAL DATA The submersible gearmotor is totally enclosed, non-ventilated (TENV), hermetically sealed submersible type. Automatic reset normally closed thermal overload protection, pre-lubricated shaft bearings, Class H winding insulation. The power cable provided is sized for the specified electrical service. See the Digital Controller Manual 820 for additional details and the electrical schematic. 840 Sub Gearmotor Swr Chwr.doc 8/11/2010 8
9 J. GEARMOTOR CROSS-SECTION DRAWING 29 9B 9A 11 9C PARTS LIST ROTOR STATOR MOTOR SHAFT THRUST BEARING HOUSING THRUST BEARING CAP STATOR HOUSING RADIAL BEARING HOUSING 1 9A 9B CAP CABLE CONNECTOR MODULE 2 9C 10 MODULAR TERMINAL BLOCK THRUST BEARING RADIAL BEARING SEAL SHAFT SLEEVE LIFTING BAIL THRUST BEARING SNAP RING "HEAVY SHOCK" CYCLOIDAL TYPE SPEED REDUCER OUTPUT SHAFT Sub Gearmotor Swr Chwr.doc 8/11/2010 9
AC Submersible Pump Motors Installation & Operating Manual
AC Submersible Pump Motors Installation & Operating Manual 2/12 Any trademarks used in this manual are the property of their respective owners. Table of Contents Section 1 General Information... Overview...
More informationINSTALLATION AND MAINTENANCE INSTRUCTIONS FOR THREE PHASE INDUCTION MOTORS
INSTALLATION AND MAINTENANCE INSTRUCTIONS FOR THREE PHASE INDUCTION MOTORS Frames 143T - 449TZ 5100 North IH 35 Round Rock, Texas 78681 Phone: 800-451-8798 512-255-4141 Fax: 512-244-5512 RECEIVING 1. Check
More informationSINGLE PHASE MOTORS. INSTALLATION AND MAINTENANCE MANUAL March 21, 2006
SINGLE PHASE MOTORS INSTALLATION AND MAINTENANCE MANUAL March 21, 2006 Irvine, California (800) 474-0520 Indianapolis, Indiana (800) 866-7973 Hamilton, Ontario (800) 809-0330 e-mail: sales@sterlingelectric.com
More informationWE-350 Series ¼ Turn Electric Actuator
WE-350 Series ¼ Turn Electric Actuator Operation and Installation Manual Pg 1 (Rev. 020113) Table of Contents 1.0 General 1.1 Pre-Installation Inspection 1.2 Storage 1.3 Features & General Information
More informationElectric Panel Pump Control System. Operation, Maintenance and Installation Manual
Manual No. 5EP-OM1-1 Electric Panel Pump Control System Operation, Maintenance and Installation Manual INTRODUCTION... 1 RECEIVING AND STORAGE... 1 DESCRIPTION OF OPERATION... 1 INSTALLATION... 2 SEQUENCE
More informationOperating Manual. Los Angeles Abrasion Machine HM-70A & HM-70AF
Operating Manual Los Angeles Abrasion Machine HM-70A & HM-70AF Rev: 07/19/2012 PHONE: 800-444-1508 P.O. Box 200, Lewis Center, Ohio 43035-0200 FAX: 800-255-5314 740-548-7298 E-mail: customerservice@gilsonco.com
More informationPump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling
Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling 250_P1 R10/7/2015 Copyright 2015 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice.
More informationOil and Coolant Circulating Heating System. Model - OCSM
Oil and Coolant Circulating Heating System Model - OCSM Installation & Operation Manual 216280-000 REV 2 Identifying Your System The HOTSTART heating system is designed to heat fluids for use in marine
More informationwith MERCURY FREE 1 HP Relays ! WARNING Before using this product read and understand instructions.
B Installation & Maintenance Instructions MM-414 Series 150E and 157E Low Water Cut-Off/Pump Controllers For Steam Boilers and Other Level Control Applications A Typical Applications: Primary or secondary
More informationCONTROL PANEL INSTALLATION INSTRUCTIONS. Single Phase Simplex Page 2-7. 3-Phase Simplex Page 8-13
CONTROL PANEL INSTALLATION INSTRUCTIONS Single Phase Simplex Page 2-7 3-Phase Simplex Page 8-13 Single Phase Simplex SXL21=3, SXL24=3, SXH21=3, and SXH24=3 Manufactured by SJE-Rhombus Installation Instructions
More informationDry Pit Solids Handling Pumps
Dry Pit Solids Handling Pumps A Time-Tested Leader Chicago Pump Dry Pit Solids Handling Pumps have an established reputation of efficiency, long life and reliable operation First in: Quality 3Reliability
More informationIMPORTANT SAFETY NOTICE
IMPORTANT SAFETY NOTICE To: Our Valued Customers User safety is a major focus in the design of our products. Following the precautions outlined in this manual will minimize your risk of injury. ITT Goulds
More information3620 W 11th Streetб Houston, TX 77008 Telephone: 713-635-6291 Email: sales@kellogg-american.com Website: www.kellogg-american.com
Unpackaging & Handling Be sure to carefully inspect the unit before accepting the shipment. If any damage has occurred document it with the trucking company immediately. Contact your Kellogg Distributor
More informationARCO Electric Products Installation and Maintenance Manual Low Voltage Automatic Power Factor Correction Capacitor Systems 2013
ARCO Electric Products Installation and Maintenance Manual Low Voltage Automatic Power Factor Correction Capacitor Systems 2013 READ CAREFULLY These instructions are intended to cover good practices in
More informationIndustrial Process Pump Safety Manual IMPORTANT SAFETY NOTICE
Industrial Process Pump Safety Manual IMPORTANT SAFETY NOTICE To: Our Valued Customers User safety is a major focus in the design of our products. Following the precautions outlined in this manual will
More information3. SEISCO PARTS & SERVICE REMOVAL AND REPAIR GUIDE
4 3. SEISCO PARTS & SERVICE REMOVAL AND REPAIR GUIDE A. Changing the Control Board B. Replacing a Heating Element C. Thermistor Replacement D. High Limit Switch Replacement E. Level Detector Replacement
More informationWilo SP Series Submersible Sump Pumps ECS. ECS19-15.25 ECS22-15.33 ECS24-15.50 Installation and operating instructions
Wilo SP Series Submersible Sump Pumps ECS ECS19-15.25 ECS22-15.33 ECS24-15.50 Installation and operating instructions PREINSTALLATION CHECK Inspect this pump before it is used. Occasionally, pumps can
More informationIEC Three Phase AC Motors (Aluminum Frame) Installation & Operating Manual
IEC Three Phase AC Motors (Aluminum Frame) Installation & Operating Manual 7/09 MN301 Table of Contents Section 1 General Information.................................................. 1-1 Overview........................................................
More informationLOBOY 16 AIR CONDITIONERS
INSTRUCTION MANUAL FOR: LOBOY 16 AIR CONDITIONERS McLean Midwest Corp. dba: McLean Cooling Technology 11611 Business Park Blvd. N Champlin, MN 55316 Tel: 763-323-8200 Fax: 763-576-3200 www.mcleancoolingtech.com
More informationABB ! CAUTION. Type COQ Negative Sequence Generator Relay. (50/60 Hertz) 41-161J. Instruction Leaflet
ABB Instruction Leaflet 41-161J Effective: May 1997 Supersedes I.L. 41-161H Dated July 1984 ( ) Denotes Change Since Previous Issue Type COQ Negative Sequence Generator Relay (50/60 Hertz)! CAUTION Before
More informationTABLE OF CONTENTS. SECTION 1 General Information: Pg 2 Description of Operation
GTRDD SERIES HEATLESS DRYER INSTALLATION, OPERATION & MAINTENANCE MANUAL TABLE OF CONTENTS SECTION 1 General Information: Pg 2 Description of Operation SECTION 2 Safety Instructions: Pg 3 Installation
More informationJOB or CUSTOMER: ENGINEER: CONTRACTOR: SUBMITTED BY: SPECIFICATION REF: QUANTITY TAG NO. MODEL NO. GPM FEET LEAD LENGTH COMMENTS.
Redi-Flo2, 2 Environmental Submersible Pumps MP1 Submittal Data QUANTITY TAG NO. MODEL NO. GPM FEET LEAD LENGTH COMMENTS Technical Data Motor Type: Water-Filled, variable speed submersible Maximum Fluid
More informationINSTALLATION and OPERATION RANGE BALL CONVEYOR MODEL NO: BC-001AN
Easy Picker Golf Products, Inc. 415 Leonard Blvd. N., Lehigh Acres, FL 33971 PH: 239-368-6600 FAX: 239-369-1579 Service: 800-982-4653 SALES: 800-641-4653 www.easypicker.com salesdept@easypicker.com INSTALLATION
More informationService Guide 12/27/03 TESTING, SERVICE & REPAIR GUIDE (For SH Space Heating Models & RA Water Heating Models)
TESTING, SERVICE & REPAIR GUIDE (For SH Space Heating Models & RA Water Heating Models) WARNING - HIGH VOLTAGE AC electrical circuits are connected to this heater. Do not attempt any service work on the
More information! WARNING. McDonnell & Miller Installation & Maintenance Instructions MM-217(I) Series 150S and 157S (Snap Switch, All Models except 157S-RB-P)
Series 150S and 157S (Snap Switch, All Models except 157S-RB-P) Low Water Cut-Off/Pump Controllers For Steam Boilers and Other Level Control Applications McDonnell & Miller Installation & Maintenance Instructions
More informationWater Leak Detection System
Water Leak Detection System Installation and Operating Manual 505-334-5865 ph 505-334-5867 fax www.rodisystems.com email:info@rodisystems.com 936 Highway 516 Aztec, NM 87410-2828 Manual Revisions and Copyright
More informationPump Specifications 2448LSG, 2448LSGX Series Omnivore 2HP Simplex Grinder Packages
Pump Specifications 2448LSG, 2448LSGX Series Omnivore 2HP Simplex Grinder Packages 2448LSG_P1 R4/2/2012 Copyright 2012 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice.
More informationSECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM
SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Packaged rooftop air conditioning unit (5 tons and smaller). 2. Roof curb. 1.2
More informationSECTION 15750 PACKAGED ROOFTOP AIR CONDITIONING UNITS
SECTION 15750 PART 1 - GENERAL 1.01 DESCRIPTION A. Section includes requirements for roof mounted, self-contained units, with electric cooling, and electric or reverse refrigeration cycle (heat pump) heating
More informationConvection Ovens. BX Classic. Models BX4 / FG 189C, BX4-6040 / FG 158C, BX10 / FG 180C. Operator's Manual
Convection Ovens BX Classic Models BX4 / FG 189C, BX4-6040 / FG 158C, BX10 / FG 180C Operator's Manual Belshaw Bros., Inc. 814 44 th Street NW, Suite 103 Auburn, WA 98001 USA Phone: 206-322-5474 Fax: 206-322-5425
More informationRAY-MAX Integrated Solar Power Strip
RAY-MAX Integrated Solar Power Strip 600008, 600009, 600010, 600208, 600209, 600210 Owner s Manual NEXTRONEX, INC. Revision Date: 10/27/14 Contents 1. Safety Instructions... 3 2. General Equipment Warnings...
More informationOPL BASIC. Dosing System for Professional Laundry machines. Contents
OPL BASIC Dosing System for Professional Laundry machines Contents 1 Getting Started. Page 2 2 Installation. Page 4 3 Set Up & Operation. Page 8 4 Maintenance & Accessories. Page 10 5 Troubleshooting Page
More informationOASIS-PLUS 120V READ ALL INSTRUCTIONS BEFORE OPERATING READ ALL INSTRUCTIONS BEFORE OPERATING OZONE IS A POWERFUL OXIDIZER AND MUST BE USED WITH CARE
OASIS-PLUS 120V INFORMATION & OPERATING INSTRUCTIONS READ ALL INSTRUCTIONS BEFORE OPERATING READ ALL INSTRUCTIONS BEFORE OPERATING OZONE IS A POWERFUL OXIDIZER AND MUST BE USED WITH CARE 56041852 WARNING:
More information2100, 2200, 2300, 4100, 6200, MPB Series Side Mount Drive Package for Standard Load 90 Industrial Gearmotors
00, 00, 300, 400, 600, MPB Series Side Mount Drive Package for Standard Load 90 Industrial Gearmotors Installation, Maintenance & Parts Manual Featuring: Technology DORNER MFG. CORP. INSIDE THE USA OUTSIDE
More informationPump Specifications 405 Series Commercial Drain Pump (High-Temp) 2 Solids handling
Pump Specifications 405 Series Commercial Drain Pump (High-Temp) 2 Solids handling 405_P1 R1/27/2012 Copyright 2012 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice.
More informationPackaged Terminal Air Conditioner Wall Sleeve Installation
Installation & Maintenance Data IM 1196 Group: PTAC Part Number: 910141799 Date: October 2013 Packaged Terminal Air Conditioner Installation x 42" PGAN with Top-Mounted Hydronic Heat Note: Installation
More informationCoolWave r 2 Phase Control Board and Cable Replacement Kits
Instruction Sheet P/N 1102452A CoolWave r 2 Phase Control Board and Cable Replacement Kits Two kits are available to replace the CoolWave 2 phase control board: S S Phase Control Board and Cable Kit (required
More informationMTE SERIES RLW. World REACTORS USER MANUAL PART NO. INSTR 030 REL. 090930. 2009 MTE Corporation
MTE SERIES RLW World REACTORS USER MANUAL PART NO. INSTR 030 REL. 090930 2009 MTE Corporation IMPORTANT USER INFORMATION NOTICE MTE Series RLW reactors are components designed to improve the reliability
More informationInstallation Instructions for Alarm Module Kit A043F059
Instruction Sheet 07-2013 Installation Instructions for Alarm Module Kit A043F059 1 Introduction The information contained within is based on information available at the time of going to print. In line
More informationSECTION 807 PUMP STATION REHABILITATION
SECTION 807 PUMP STATION REHABILITATION 807-1 DESCRIPTION: Rehabilitation of pump stations shall be defined as the cleaning, removal, repair and/or replacement of any and/or all components including but
More information2. Remove rear cover of head lamp if bulbs are covered/sealed within the housings, and remove halogen bulb carefully.
These instructions are designed to address most general installation procedures across vehicles and should not be considered vehicle make, model or year specific. Please contact the vendor directly for
More informationSDX Submersible Depth Transmitter User Manual
SDX Submersible Depth Transmitter User Manual January 2011 USER INFORMATION Stevens makes no warranty as to the information furnished in these instructions and the reader assumes all risk in the use thereof.
More informationPROAIR Water-Cooled Air Conditioner. CR43WC Model INSTRUCTION MANUAL. Rev. E 2013 Pentair Technical Products P/N 10-1008-167
PROAIR Water-Cooled Air Conditioner CR43WC Model INSTRUCTION MANUAL Rev. E 2013 Pentair Technical Products P/N 10-1008-167 87976466 TABLE OF CONTENTS HANDLING & TESTING THE AIR CONDITIONER...3 INSTALLATION
More informationOwners & Installation Manual for the Sheridan, Mountainair, Pine Valley and Old Forge Ceiling Fan Family
Owners & Installation Manual for the Sheridan, Mountainair, Pine Valley and Old Forge Ceiling Fan Family Part of the Kiva Lighting Family Custom Lighting and Fans Since 1992 1312 12th St NW Albuquerque,
More informationSERVICE MANUAL RESIDENTIAL ELECTRIC AND LIGHT DUTY COMMERCIAL ELECTRIC WATER HEATERS. Troubleshooting Guide and Instructions for Service
RESIDENTIAL ELECTRIC AND LIGHT DUTY COMMERCIAL ELECTRIC WATER HEATERS SERVICE MANUAL Troubleshooting Guide and Instructions for Service (To be performed ONLY by qualified service providers) Models Covered
More informationInstallation and Operating Instructions (for chargers shown below)
Installation and Operating Instructions (for chargers shown below) For additional information please call our Technical Support Group 800.742.2740 PRO CHARGING SYSTEMS, LLC 1551 Heil Quaker Boulevard,
More informationGlobal Water Instrumentation, Inc.
Global Water Instrumentation, Inc. 11390 Amalgam Way Gold River, CA 95670 T: 800-876-1172 Int l: (916) 638-3429, F: (916) 638-3270 Solar Panels 2 Watt Solar Panel: SP101 5 Watt Solar Panel: SP102 01-752
More informationWGL20, WGL20H, WGL20F Grinder Pumps
WGL20, WGL20H, WGL20F Grinder Pumps Installation and Service Manual 2012 Pentair Pump Group, Inc. 23833A032 03/12 Thank you for purchasing your Myers Pump. To help ensure years of trouble-free operation,
More informationELECTRICAL CONTRACTORS THE UNIVERSITY OF TENNESSEE KNOXVILLE, TENNESSEE SECTION 16050 PAGE 1
KNOXVILLE, TENNESSEE SECTION 16050 PAGE 1 PART 1 - GENERAL 1.01 RELATED DOCUMENTS: SECTION 16050 A. Drawings and general provisions of Contract, including General and Supplementary Conditions and Division-1
More informationInstallation Manual Version 7.3 IMPORTANT:
Installation Manual Version 7.3 IMPORTANT: READ ENTIRE MANUAL CAREFULLY, THIS PHASE CONVERTER MUST BE INSTALLED BY A INDUSTRIAL LICENSED ELECTRICIAN 230 VOLTS MODEL ONLY READ FIRST!!!!!! DANGER: HIGH VOLTAGE
More informationChromalox. Installation, Operation. Portable Industrial Unit Blower Air Heater Type DRA RENEWAL PARTS IDENTIFICATION
Chromalox Installation, Operation RENEWAL PARTS IDENTIFICATION Portable Industrial Unit Blower Air Type DRA and DIVISION SALES REFERENCE DATE SECTION (Supersedes P-) PF-) NOVEMBER, 00 DRA PF- -0-00 Specifications
More informationTERMINAL MARKINGS AND INTERNAL WIRING DIAGRAMS SINGLE PHASE AND POLYPHASE MOTORS MEETING NEMA STANDARDS
INTRODUCTION The following represents the most up-to-date information on motor terminal marking for proper connection to power source for all alternating current motors manufactured in accordance with
More informationMG1532 & MG2032 MIXER-GRINDERS
MIXER-GRINDER MG1532 & MG2032 MIXER-GRINDERS MODEL MG1532 ML-134099 7.5 HP Grind Motor + 1 HP Mix Motor MG1532 ML-134103 5 HP Grind Motor + 1 HP Mix Motor MG1532 ML-134100 7.5 HP Grind Motor + 1 HP Mix
More information..OR How To Protect your 3-Phase Equipment Investment with 3-Phase Monitors from Time Mark...
..OR How To Protect your 3-Phase Equipment Investment with 3-Phase Monitors from Time Mark... TIME MARK CORPORATION 11440 EAST PINE STREET TULSA, OK 74116 USA tel 918 438-1220 fax 918 437-7584 www.time-mark.com
More informationi ChatterBox! Motorcycle Security
i Before you Start the Installation * Please read this manual to become familiar with the requirements necessary to complete the installation. * Use a high quality multi-meter to test all wires before
More informationOEM Manual MODEL 2350 ELECTRONIC DUAL CYLINDER SCALE
OEM Manual MODEL 2350 ELECTRONIC DUAL CYLINDER SCALE Scaletron Industries, Ltd. Bedminster Industrial Park 53 Apple Tree Lane P.O. Box 365 Plumsteadville, PA 18949 USA Toll Free: 1-800-257-5911 (USA &
More informationHG600/HG800. Hydro-Power Unit. Installation and Operation Guide
HG600/HG800 Hydro-Power Unit Installation and Operation Guide Copyright 04 HydroSpin, All rights reserved. The data contained in this document is proprietary to HydroSpin. It is disclosed to the receiving
More informationCable Tester Pro ORDERCODE D1909
Cable Tester Pro ORDERCODE D1909 Congratulations! You have bought a great, innovative product from DAP Audio. You can rely on DAP Audio, for more excellent audio products. We design and manufacture professional
More informationSERVICE MANUAL FOR 6535 SERIES TWO TON HIGH EFFICIENCY PACKAGED HEAT PUMPS
SERVICE MANUAL FOR 6535 SERIES TWO TON HIGH EFFICIENCY PACKAGED HEAT PUMPS TABLE OF CONTENTS 1. Warnings...2 2. Accessibility Of Appliance...3 3. Unit Dimensions And Specifications...3 4. Unit Specifications
More informationTECHNICAL SUPPORT MANUAL 3 Phase Air Conditioner Component R2A3**GHR
3 Phase Air Conditioner Component R2A3**GHR DANGER, WARNING, CAUTION, and NOTE The signal words DANGER, WARNING, CAU- TION, and NOTE are used to identify levels of hazard seriousness. The signal word DANGER
More informationService manual. Website: www.andico.com.au CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL.
Website: www.andico.com.au Service manual CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL. - ONLY FOR AUTHORISED SERVICE PERSONNEL. MODELS: MPK1-09CR-QB8 MPK1-12ER-QB6
More informationRegal Beloit AC Motors
Installation, Operation and Maintenance Instructions for Industrial AC Induction Motors 140-6800 Frames (NEMA) 90 280 Frames (IEC) Regal Beloit AC Motors LEESON ELECTRIC Contact Motor Customer Service
More informationMODEL 341A SINGLE STAGE END SUCTION PUMPS
MODEL 44A MODEL 42A MODEL 41A MODELS 41A, 42A and 44A SINGLE STAGE END SUCTION PUMPS INSTRUCTION AND REPAIR MANUAL NOTE! To the installer: Please make sure you provide this manual to the owner of the equip
More informationUtility Distribution Systems
Utility Distribution Systems 6/2012 A0011037 1 WARRANTY This equipment is warranted to be free from defects in materials and workmanship, under normal use and service, for a period of 12 months from date
More informationBC & BCH SERIES INDOOR / OUTDOOR INSTALLATION
Air Conditioning Central Heating & Cooling BC & BCH SERIES INDOOR / OUTDOOR INSTALLATION INSTALLATION AND SERVICE MANUAL 2 PROJECT: ADDRESS: MODEL: SERIAL NUMBER: INSTALLER: ADDRESS: PHONE NUMBER: INSTALLATION
More informationInstallation, Operation and Maintenance Instructions
Installation, Operation and Maintenance Instructions for AC Induction Motors 56-6800 Frames (NEMA) 63 280 Frames (IEC) MARATHON ELECTRIC Contact Motor Customer Service at: Phone: (75) 675-33 www.marathonelectric.com
More informationT-Series Air Conditioner T62 Model
INSTRUCTION MANUAL T-Series Air Conditioner T62 Model Protecting Electronics. Exceeding Expectations. McLean Cooling Technology 11611 Business Park Blvd N Champlin, MN 55316 USA Tel 763-323-8200 Fax 763-576-3200
More informationDC400 Dispensing Cutoff System
DC400 Dispensing Cutoff System DC404 and DC406 Installation Instructions Franklin Fueling Systems 3760 Marsh Rd. Madison, WI 53718 USA Tel: +1 608 838 8786 800 225 9787 Fax: +1 608 838 6433 www.franklinfueling.com
More informationA. Shop Drawing submittals shall include, but not be limited to, the following:
SECTION 26 05 53 IDENTIFICATION FOR ELECTRICAL SYSTEMS PART 1 - GENERAL 1.1 RELATED DOCUMENTS: A. The Conditions of the Contract and applicable requirements of Divisions 0 and 1 and Section 26 00 01, Electrical
More information12-Volt Negative Ground Installation Instructions
12-Volt Negative Ground Installation Instructions For Part Number: 1141, 1164, 1165, 1181 CAUTION!!! Before installing, please read the following important information... 1. The Ignitor is designed for
More informationElectric Meat Grinder
Electric Meat Grinder OWNER S MANUAL WARNING: Read carefully and understand all INSTRUCTIONS before operating. Failure to follow the safety rules and other basic safety precautions may result in serious
More informationATS Overhead Table Shelf System INSTRUCTION MANUAL
ATS Overhead Table Shelf System INSTRUCTION MANUAL ATS Overhead Table Shelf System Instruction Manual Warranty Newport Corporation warrants this product to be free of defects in material and workmanship
More informationInstallation and Operating Instructions (for chargers shown below)
Installation and Operating Instructions (for chargers shown below) For additional information please call our Technical Support Group 800.742.2740 PRO CHARGING SYSTEMS, LLC 1551 Heil Quaker Boulevard,
More informationSubmit shop drawings for equipment provided under this section Shop drawings shall indicate:
Section 16435 - SWITCHBOARDS Introduction Part 1 - General Reference The work under this section is subject to requirements of the Contract Documents including the General Conditions, Supplementary Conditions,
More information543-0032-00, 943-0032-00. User s Manual
543-0032-00, 943-0032-00 User s Manual 1 Comfort Alert Diagnostics Faster Service And Improved Accuracy The Comfort Alert diagnostics module is a breakthrough innovation for troubleshooting heat pump and
More informationTECHNICAL INFORMATION Bulletin
Peerless Pump Company 2005 Dr. M.L. King Jr. Street, P.O. Box 7026, Indianapolis, IN 46207-7026, USA Telephone: (317) 925-9661 Fax: (317) 924-7338 www.peerlesspump.com www.epumpdoctor.com TECHNICAL INFORMATION
More informationAll work must conform to the National Electric Code, latest edition, and all other applicable codes and regulations.
DIVISION 16 ELECTRICAL SECTION 16100 - ELECTRICAL PART 1 - GENERAL SCOPE All electrical work as shown on the drawings and as necessary to provide a complete electrical system. Include primary service,
More informationPANCAKE CAPACITOR GENERATOR Installation, Operation and Maintenance Manual
PANCAKE CAPACITOR GENERATOR Installation, Operation and Maintenance Manual A Regal Brand TABLE OF CONTENTS INTRODUCTION 2 General Data 2 Initial Inspection 2 SAFETY 2 INSTALLATION 3 Location / Environment
More informationInstallation Instructions for Solar Pumps USER MANUAL FOR SPS, SPC, SPSC SPQB, SPGJ SERIES SOLAR PUMPS AND PUMP CONTROLLERS
Installation Instructions for Solar Pumps USER MANUAL FOR SPS, SPC, SPSC SPQB, SPGJ SERIES SOLAR PUMPS AND PUMP CONTROLLERS PO Box 80, Tuakau 2342 ph 0800 14 48 65 e-mail: hunkin-garden@xnet.co.nz www.hunkin.co.nz
More informationTECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER INDOOR UNIT: AW52AL AW64AL AW52AL 387030095 AW64AL 0.8180.463.0 07/05
TECHNICAL DATA & SERVICE MANUAL INDOOR UNIT: AW52AL AW64AL SPLIT SYSTEM AIR CONDITIONER Model No. Product Code No. AW52AL 387030095 AW64AL 387030096 0.8180.463.0 07/05 IMPORTANT! Please read before installation
More informationAC Electric Motors best practice
If you want to learn more about best practice machinery maintenance, or world class mechanical equipment maintenance and installation practices, follow the link to our Online Store and see the Training
More informationHQ Series ¼ Turn Actuator
HQ Series ¼ Turn Actuator HQ-015 thru HQ-300 Installation & Maintenance Manual HQ Series I&M Manual HQ-400-1005 1 Table of Contents: General 1.0 Actuator Mounting 2.0 External Construction 3.0 Wiring Diagrams
More informationAddendum to the Operating Instructions
Drive Technology \ Drive Automation \ System Integration \ Services Addendum to the Operating Instructions MOVIMOT with AS-Interface and AC Motor DT/DV Unit Replacement MOVIMOT MM..C -> MM..D with MLK3A
More informationFire Pump Applications
Fire Pump Applications Installation & Maintenance Manual Universal Joint Driveshafts www.cumminsfirepower.com Table of Contents Section 1 General 1.1 Introduction 1.2 Safety Precautions 1.3 Warranty Statement
More informationRI-215A Operator s Manual. Part Number: 71-0045RK Revision 0 Released: 10/3/05
RI-215A Operator s Manual Part Number: 71-0045RK Revision 0 Released: 10/3/05 Warranty RKI Instruments, Inc., warrants gas alarm equipment sold by us to be free from defects in materials and workmanship,
More informationMechanical Installation
Page -1-1. INTRODUCTION AND PURPOSE 1.1. This specification covers the installation, testing and precommissioning of mechanical equipment. Work is to be performed in conjunction with the manufacturer s
More informationAndersen Electric Window Opener for Andersen Awning and Roof Windows
W A Electric Window Opener Electric Window Opener for Awning and Roof Windows Congratulations! You have just purchased one of the many fine products. For ease of installation and continued enjoyment of
More informationprestige Condensing Water Boiler SERVICE TECHNICIAN S TROUBLE SHOOTING GUIDE 2008-36 TSG-PRESTIGE Date revised: 12/6/10
prestige Condensing Water Boiler SERVICE TECHNICIAN S TROUBLE SHOOTING GUIDE Date revised: 12/6/10 2008-36 TSG-PRESTIGE Table of Contents INTRODUCTION Page 1-2 SERVICING TIPS AND INSTRUCTIONS Page 3-4
More informationTOP RUNNING SINGLE GIRDER BRIDGE CRANE
SECTION 14630 TOP RUNNING SINGLE GIRDER BRIDGE CRANE 1.01 SUMMARY PART 1- GENERAL A. The work required under this section shall include the designing, manufacturing, shipping, installing and field testing
More informationDANGER DANGER. General Information. Safety Is Your Responsibility. Ordering Parts. Contact Information
Safety Safety Is Your Responsibility DANGER To avoid personal injury or death, carefully read and understand all instructions pertaining to the Anthony Liftgates product. Do not attempt to install, operate,
More informationParts Replacement Manual For DODGE TORQUE-ARM Speed Reducers Straight Bore & Taper Bushed
Parts Replacement Manual For TORQUE-ARM Speed Reducers Straight Bore & Taper Bushed TXT815A - TXT825A SIZES: TXT915A - TXT926A TXT1015A - TXT1024A WARNING: Because of the possible danger to person(s) or
More informationPBX Series Quick Fit Connector Bimetallic Steam Traps
6262100/6 IM-P626-01 ST Issue 6 PBX Series Quick Fit Connector Bimetallic Steam Traps Installation and Maintenance Instructions 1. Safety information 2. General product information 3. Installation 4. Commissioning
More informationFIRE ALARM AND DETECTION SYSTEMS SECTION 16721
PART 1 - GENERAL 1.01 WORK INCLUDED FIRE ALARM AND DETECTION SYSTEMS SECTION 16721 A. Provide a complete fully addressable, power limited, fire detection and evacuation system. The system shall be connected
More informationUHIR Series. Horizontal or Vertical Mounting Industrial / Commercial Electric Unit Heater. Owner s Manual
UHIR Series Horizontal or Vertical Mounting Industrial / Commercial Electric Unit Heater Owner s Manual This manual covers installation, maintenance and repair parts. Read carefully before attempting to
More informationTri-Homo Style Operation and Maintenance Instructions
Tri-Homo Style Operation and Maintenance Instructions One Research Drive Stratford, CT 06615 (203) 375-0063 www.sonicmixing.com 1 Installation and Start-up Do not perform following adjustments without
More informationCooktop Low-Profile Ventilation Hoods
INSTALLATION GUIDE Cooktop Low-Profile Ventilation Hoods Contents Wolf Cooktop Low-Profile Ventilation Hoods........ 3 Cooktop Low-Profile Hood Specifications.......... 4 Cooktop Low-Profile Hood Installation............
More informationParts#MB003-003 Reverse Gear MAMBA (Monoblock for Cable operated) For 5 speed Trans., '87 to '06 Big Twin models (except '06 Dyna)
Installation Instructions Reverse Gear MAMBA (Monoblock for Cable operated) Read and become familiar with these installation instructions before start. Two Piece for H-D 5 Speed Trans., Cable operated
More informationNME650R INTRODUCTION. Table of Contents. Parts Lists and Wiring Diagrams are located in the center of this manual, printed on yellow paper.
INTRODUCTION To the owner or user: The service manual you are reading is intended to provide you, and the maintenance or service technician, with the information needed to install, start up, clean, maintain,
More informationGENERATOR. 280 430 Frame Installation, Operation, and Maintenance Manual. Marathon Electric Mfg. Corp.
GENERATOR 280 430 Frame Installation, Operation, and Maintenance Manual Marathon Electric Mfg. Corp. A REGAL-BELOIT COMPANY P.O. Box 8003 Wausau, WI 54402-8003 Phone: (715) 675 3359 Fax: (715) 675 8026
More informationManual for Fire Suppression & Methane Detection System
Manual for Fire Suppression & Methane Detection System Fogmaker North America Post address: 150 Gordon Dr Exton, PA 19341 Delivery address: 150 Gordon Dr Exton, PA 19341 Tel: 610-265-3610 Fax: 610-265-8327
More information