FP1-H GOLD CX Fläkt 2/ Fan 2 *E *F *G. Fläkt 1/ Fan 1 SE/GB.ELCX Temperature sensor 4. Temperaturgivare 4/ Humidity sensor
|
|
- Nathan May
- 8 years ago
- Views:
Transcription
1 *B GOLD CX Temperaturgivare tilluft/ Temperature sensor, in supply air Fläkt / Fan Filter/ Filter Fläkt/Fan 3 *J FP-H *I T 3 T ST *E *F *G *H Cirkulationspump/ Circulation pump Ventilställdon/ Valve actuator Temperaturgiv. tilluft/ Temperature sensor, supply air Handterminal/ Hand-held micro terminal *Q *P T 4 ST 2 Filter/Filter 4 Rörkopplingsenhet/ Pipework package Fläkt/Fan 2 *K Begränsningstemp. givare/ Temperature limiting sensor DIL-omkopplare/ DIP switches Bus-kontakter/ Bus connections Eftervärme/ Reheater Trafo/ Transformer 230 V Fläkt 2/ Fan 2 *B
2 P: GOLD CX Fläktplacering, högerutförande/ Fan Arrangement, right-hand version Begränsningsgivare/ Limit sensor Dip-omkopplare/ Dip switch settings: 5 = ON -4, 6 = OFF Styr / Control Styr 2/ Control 2 Uteluft/ Tilluft/ Frånluft/ Avluft/ Outdoor air Supply air Extract air Exhaust air Fläktplacering, vänsterutförande/ Fan Arrangement, left-hand version Temperaturgivare 2/ Temperature sensor 2 Dip-omkopplare/Dip switch settings:, 5 = ON 2-4, 6 = OFF Temperaturgivare 2/ Temperature sensor 2 Styr / Control Styr 2/ Control 2 Begränsningsgivare/ Limit sensor Uteluft/ Tilluft/ Frånluft/ Avluft/ Outdoor air Supply air Extract air Exhaust air 2
3 Fläktplacering 2, högerutförande/ Fan Arrangement 2, right-hand version Dip-omkopplare/Dip switch settings: 5 = ON -4, 6 = OFF Styr / Control Styr 2/ Control 2 Begränsningsgivare/ Limit sensor Uteluft/ Tilluft/ Frånluft/ Avluft/ Outdoor air Supply air Extract air Exhaust air Fläktplacering 2, vänsterutförande/ Fan Arrangement 2, left-hand version Begränsningsgivare/ Limit sensor Dip-omkopplare/Dip switch settings:, 5 = ON 2-4, 6 = OFF Temperaturgivare 2/ Temperature sensor 2 Styr / Control Styr 2/ Control 2 Temperature sensor3 Temperaturgivare 2/ Temperature sensor 2 Uteluft/ Tilluft/ Frånluft/ Avluft/ Outdoor air Supply air Extract air Exhaust air 3
4 B: GOLD RX/PX/CX/SD 4-80 PE U V W PE L L2 L3 MOTOR Gulgrön/Yellow green Brun/ Brown Svart/Black Grå/Grey Motor/Motor 3/W 2/V /U Gulgrön/Yellow green FCC BUS Kraftkabel/ Power supply cable Styrkabel/ Control cable 4
5 E: GOLD RX/PX/CX 4-80 Svart/Black Grå/Grey Gulgrön/Yellow green Inkoppling av kraftkablar på motorskyddsbrytare/ To wire power supply cables to the protective motor switch Aggregat stl./ Inställning Inställning AHU size motorskyddsbrytare motorskyddsbrytare fläktar (A)/ cirkulationspump rörkopplingsenhet (A)/ Setting, protective Setting, protective motor switch motor switch fans (A) pipework package circulation pump (A) 4 6,3 20 6, ,5,8 40 2,5,8 50 0,8 60 0,8 70 2,5 2, ,5 2,35 F: GOLD CX Inkoppling av kraftkabel på kontakter för rörkopplingsenhetens cirkulationspump/ To wire the power supply cable to the contacts for the pipework package circulation pump Svart/Black Grå/Grey Gulgrön/Yellow green G: GOLD CX L3 L2 L Inkoppling av kraftkabel i rörkopplingsenhetens cirkulationspump/ To wire the power supply cable in the pipework package circulation pump T T2 GRUNDFOS T T2 L3 L2 L Gulgrön/ Yellow green Grå (Blå)/Grey (Blue) Svart/Black 5
6 H: GOLD CX Inkoppling av rörkopplingsenhetens ventilställdon/ To wire the pipework package valve actuator U M R Y G G0 Vit U/ White - U Gul Y/ Yellow - Y Brun G/ Brown - G Grön G0/ Green G0 I: GOLD CX Grön/Green Gul/Yellow Vit/ White Vit/ White Inställning av IQnomic Plusmodul omkopplarläge / Selector for setting the IQnomic Plus module. Switch position Kabel från begränsningsgivare på shuntgrupp/ Cable from limiting sensor on the pipework package group Kabel från ventilställdon/ Cable from the valve actuator 6 Kommunikationskabel från styrenhet/communication cable from the control unit Kontaktorsvar. Kontaktoranslutning 4/ Contactor response Contactor connection 4 Kontaktorsvar. Kontaktoranslutning 3/Contactor response Contactor connection 3 Startpump.Kontaktoranslutning A/Start pump. Contactor connection A 230 V. Plint 0/ 230 V. Terminal 0
7 J: GOLD RX/PX/CX/SD Styrkablar med snabbkoppling/ Control cables with quick connector Slav/Slave B A Pos/Pos. FCC/ FCC Fläkt / Fan 6 6 CC Tryckgivare sida / Pressure transducer Side B A K: GOLD RX/PX/CX/SD Styrkablar med snabbkoppling/ Control cables with quick connector Slav/Slave B FCC/ FCC CC2 B A Pos/Pos. Fläkt 2/ Fan Tryckgivare sida 2/ Pressure transducer Side 2 A
8 Q: GOLD RX/PX/CX/SD DIL-omkopplare/DIP switches ON OFF DIL-omkopplare Funktion i läge Funktion i läge nummer OFF (nedåt) ON (uppåt) Tilluftsfläkt höger Tilluftsfläkt vänster (högerinspektion) (vänsterinspektion) 2 Enhetsaggregat (RX/PX/CX) Tillufts- + frånluftsaggregat (SD) 3 Aggregat med två Tillufts- eller frånluftsaggregat flödesriktningar med enbart tillufts- eller frånluftsfläkt (SD) 4 Ej plattvärmeväxlare * Plattvärmeväxlare 5 Ej batterivärmeväxlare * Batterivärmeväxlare 6 Reserv Reserv * Om båda DIL-omkopplarna 4 och 5 är i läge OFF, avser det roterande värmeväxlare. DIP switch Function in position Function in position No. OFF (downwards) ON (upwards) Supply air fan, right Supply air fan, left (right-hand inspection) (left-hand inspection) 2 One-piece unit (RX/PX/CX) Supply AHU + exhaust AHU (SD) 3 Unit with two air flow Supply AHU or exhaust AHU directions with only supply air fan or exhaust fan (SD) 4 Not plate heat exchanger * Plate heat exchanger 5 Not coil heat exchanger * Coil heat exchanger 6 Spare Spare * If both DIP switches 4 and 5 is in position OFF, it means rotary heat exchanger.
GOLD CX 120 eff.var./cap.var. 1
SE/G.ELCX20E.502 GOLD CX 20 eff.var./cap.var. Med styrenhet (i undre plan)/with control unit (in lower level) Säkerhetsbrytare/ huvudströmbrytare/ Safety switch/ main switch IQnavigator Temperaturgivare,
More informationGOLD SD 11 effektvariant 2, 12
GOLD SD effektvariant 2, 2 Med styrenhet/with control unit us-kontakter/ us connections N L Eftervärme/ Reheater Temperaturgivare för densitetskorrigerat luftflöde./ Temperature sensor for densitycorrected
More informationWeb Page Manual. GOLD RX, PX, CX, SD, Program Version 1.20
GB.webbE.0 Web Page Manual GOLD RX, PX, CX, SD, Program Version.0. General The air handling unit has a built-in web server that enables you to monitor, enter and change the settings in the air handling
More informationAIR COOLED CHILLER CHILLED WATER PUMP CONTROL: The chilled water pump with the lowest runtime will automatically start when the outside air temperature rises above the system enable setpoint. When the
More informationHVAC Processes. Lecture 7
HVAC Processes Lecture 7 Targets of Lecture General understanding about HVAC systems: Typical HVAC processes Air handling units, fan coil units, exhaust fans Typical plumbing systems Transfer pumps, sump
More informationSUPPLY VOLTAGE AIR HANDLING UNIT X101 X102 WB1 DWG. NO. 342289 EB1 DWG. NO. 342280 M1 DWG. NO. 342279 HR-R DWG. NO. 342279. Drawing no.
A SUPPLY VOLTAGE AIR HANDLING UNIT X0 X0 WB EB 0 X A F A & A M HR-R M Symb. Changes Date/Sign.... Unit Date Checked Pos. Name, type, dim. Drawn Projection Appr. Drawing no. Standard Scale Art. Replaces:
More informationE T K A 14:36 18.02.20100 970-00. Year. Illustration. Model. Seite: 001. et_bt1.frm. Pos Part Number Name Remarks Qty Model.
0 7 70-00 4:36 8.02.2000 connector housing pin 05 05 37 diode connector 2 3 4 5 6 2 05 05 37 D diode connector 7 8 0 2 3 4 5 6 7 8 20 2 22 23 24 25 26 27 28 2 30 3 32 33 34 3 357 07 7 B terminal pin housing
More informationRESERVDELAR/ SPARE PARTS
RESERVDELAR/ SPARE PARTS Washer disinfector 46-2,46-4,46-5 Mfg. no. SEV0440130-5018617-00 Reservdelslista/Spare parts catalogue Reservdelslista/Spare parts catalogue Contents Circulation system 1 5 Circulation
More informationMAKING MODERN LIVING POSSIBLE. Wiring Diagram DHP-R. www.heating.danfoss.com
MAKING MODERN LIVING POSSIBLE Wiring Diagram www.heating.danfoss.com Danfoss A/S is not liable or bound by warranty if these instructions are not adhered to during installation or service. The English
More information543-0032-00, 943-0032-00. User s Manual
543-0032-00, 943-0032-00 User s Manual 1 Comfort Alert Diagnostics Faster Service And Improved Accuracy The Comfort Alert diagnostics module is a breakthrough innovation for troubleshooting heat pump and
More informationThe compact unit series
The compact unit series The easy way to maintain a good climate i High, efficient energy recovery with an efficiency of 80 90 % i Energy-saving fan motors utilising EC technology for minimal energy consumption
More informationCOOL DX COOLING UNIT, version D Installation and Maintenance Instructions Sizes 08-80
COOL DX COOLING UNIT, version D Installation and Maintenance Instructions Sizes 08-80 The document was originally written in Swedish. CONTENTS. General Survey 3. General 3.2 Basic function diagram 4 2
More informationFailure code manual. content
Failure code manual content 一 wall split AC series 2 二 floor standing AC series. 4 三 portable AC series.. 5 四 dehumidifer 6 五 DC inverter single split series...7 六 DC inverter multi-split series 10 1 一
More informationBC & BCH SERIES INDOOR / OUTDOOR INSTALLATION
Air Conditioning Central Heating & Cooling BC & BCH SERIES INDOOR / OUTDOOR INSTALLATION INSTALLATION AND SERVICE MANUAL 2 PROJECT: ADDRESS: MODEL: SERIAL NUMBER: INSTALLER: ADDRESS: PHONE NUMBER: INSTALLATION
More informationIndoor coil is too warm in cooling mode or too cold in heating mode. Reversing valve or coil thermistor is faulty
Codes Room Air Conditioner range: Indoor unit alarm s If timer lamp flashes for 1 second on, 1 second off, this indicates pre heating on the coil during heating mode and is not an error. If timer lamp
More informationBABIES SUNNIES TEENIES. 0-4 år / years. 5-8 år / years. 7-12 år / years
2015-2015 01 12 BABIES 0-4 år / years SUNNIES 5-8 år / years TEENIES 7-12 år / years De färgade linserna har linskategori 3 vilket betyder att de är kraftigt tonade och kan användas vid intensiv solstrålning
More informationCOMMISSIONING OF HVAC SYSTEMS
FORM CL-01 SYSTEMS / EQUIPMENT INCLUDED : SYSTEM STARTUP CHECKLIST I - PRE - STARTUP INSPECTION EQUIPMENT MOUNTING & SETTING CONTROL, INTERLOCK & POWER WIRING ALIGNMENT OF MOTORS & DRIVES PIPING, CONNECTIONS
More informationR22. K Control. Indoor Unit. Nomenclature. Compatibility PL H 3 G K H B. Unit style Heat Pump Horse Power
R22. K Control. Indoor Unit. Nomenclature. PL H 3 G K H B Compatibility Unit style Heat Pump Horse Power Control Boost Heaters R22. K Control. Outdoor Unit. Nomenclature. PU H 3 Y K A Compatibility Outdoor
More information36.2101.00 - M Svart - Grå gradallins Black - Grey gradient lens Filterkategori / Filter category 2 AC
1 36.2101.00 - M Svart - Grå gradallins Black - Grey gradient lens 39.2201.10 - M Vit - Grön färgad lins White - Green coloured lens 36.2407.00 - M Svart - Grå gradallins Black - Grey gradient lens 2 36.3202.03
More informationENHANCED LABORATORY HVAC SYSTEM
ENHANCED LABORATORY HVAC SYSTEM INTRODUCTION Since the early 1980's the attention to more energy efficient laboratory designs has been on the rise due to the increase in energy cost and the emergence of
More informationThermostatic Wiring Principles by Bob Scaringe Ph.D., P.E.
Thermostatic Wiring Principles by Bob Scaringe Ph.D., P.E. Basic Thermostat Types Many technicians have great difficulty understanding how to properly wire a thermostat or how to replace a thermostat with
More informationWiring diagrams 14 1. Component key for wiring diagrams 1 to 29 Note: Not all the items listed will be fitted to all models
Wiring diagrams 14 1 Component key for wiring diagrams 1 to 29 Note: Not all the items listed will be fitted to all models No Description 00200 Alternator with built-in regulator 00500 Battery 01001 Starter
More informationMax primary circuit temperature 90ºC Max primary circuit temp. 90ºC Max secondary circuit temperature 45ºC Max secondary circuit temp.
EGLISH 1 Product description exchanger equipped with an electronic control unit and circulation pump for the primary circuit. All Aqua-Mex variants can be ordered with an interior coil of either titanium
More information10.1 Indoor Unit Error Display
10.1 Indoor Unit Error Display Display E0 E1 E2 E3 E5 E6 P0 P1 P2 P4 LED STATUS EEPROM parameter error Indoor / outdoor units communication protection Zero-crossing signal error Fan speed out of control
More informationZehnder Focus 200. Ventilation device
Ventilation device Use The Zehnder Focus (F) 200 comfort ventilation unit was specially developed for use in demanding residential and commercial buildings. It combines maximum comfort, simple operation
More informationWiring Diagram. Diplomat 400V 3N. www.thermia.com
www.thermia.com Thermia Värmepumpar is not liable or bound by warranty if these instructions are not adhered to during installation or service. The English language is used for the original instructions.
More informationKU DESIGN GUIDELINES APPENDIX XVI RECOMMENDED BAS I/O CONTROL POINTS BY EQUIPMENT / SYSTEM
KU DESIGN GUIDELINES APPENDIX XVI RECOMMENDED BAS I/O CONTROL POINTS BY EQUIPMENT / SYSTEM AIR HANDLING UNITS... 1 CHILLERS... 2 COOLING TOWERS... 2 CLOSED LOOP COOLERS... 2 MISCELLANEOUS SUPPLY FANS...
More informationS & P COIL PRODUCTS LTD SPC HOUSE, EVINGTON VALLEY ROAD, LEICESTER. LE5 5LU. Electrical layouts for EC Motors in Fan Convector units
S & P COI PRODUCTS TD SPC HOUSE, EVIGTO VAEY ROAD, EICESTER. E5 5U Guidance Document Electrical layouts for EC Motors in Fan Convector units Hasnain Merchant Richard Meskimmon 4/9/0 This document is intended
More informationSERVICE MANUAL REFRIGERATION
SERVICE MANUAL REFRIGERATION ELECTROLUX HOME PRODUCTS S.p.A. Publication no. Spares Operations Italy 599 36 16-90 Corso Lino Zanussi, 30 031117 I - 33080 PORCIA / PN (ITALY) ITZ/SERVICE/AA Fax +39 0434
More informationTEDDINGTON. Intuitive control. TLC 700 The multifunctional controller
Intuitive control TLC 700 The multifunctional controller TLC 700 The intelligent controller for complex systems TEDDINGTON As easy as Teddington air curtain systems are the ultimate when it comes to the
More informationWeb Page Manual. GOLD RX, PX, CX, SD Program Version 5.00 or better GOLD LP/COMPACT Program Version 2.00 or better
Web Page Manual GOLD RX, PX, CX, SD Program Version 5.00 or better GOLD LP/COMPACT Program Version 2.00 or better 1. GENERAL The air handling unit has a built-in web server that enables you to monitor,
More informationPNEUMATIC CONTROLS Selection and Description
PNEUMATIC CONTROLS Selection and Description Carnes pneumatic controlled throttling units are suitable for a standard 20 psi control system and may be supplied with pressure dependent or pressure independent
More informationBABIES SUNNIES TEENIES. 0-4 år / years. 5-8 år / years. 7-12 år / years
2015-2015 01 12 BABIES 0-4 år / years SUNNIES 5-8 år / years TEENIES 7-12 år / years De färgade linserna har linskategori 3 vilket betyder att de är kraftigt tonade och kan användas vid intensiv solstrålning
More informationFundamentals of HVAC Control Systems
ASHRAE Hong Kong Chapter Technical Workshop Fundamentals of HVAC Control Systems 18, 19, 25, 26 April 2007 2007 ASHRAE Hong Kong Chapter Slide 1 Chapter 5 Control Diagrams and Sequences 2007 ASHRAE Hong
More informationModels: Contents. Cabinet Components. Functional Components " Exploded View... 3 " Usage List... 4. Control Panel. Blower Housing
REPLACEMENT PARTS MANUAL WALL MOUNTED PACKAGE HEAT PUMPS Models: WH301 WH361 General Notes! Revised and/or additional pages may be issued from time to time.! A complete and current manual consists of pages
More information01-3 0000-00 6810-20 AIR CONDITIONING SYSTEM 1. FFH SPECIFICATION AIR CONDITIONING SYSTEM RODIUS 2004.09
0000-00 01-3 6810-20 1. FFH SPECIFICATION 01-4 0000-00 2. SYSTEM LAYOUT AND COMPONENTS 0000-00 01-5 01-6 0000-00 3. FFH GENERAL INFORMATION The system is to increase the coolant temperature quickly by
More informationTransporter Current Flow Diagram No. 80 / 1
Transporter Current Flow Diagram No. 80 / 1 2.5 l/65 kw direct injection turbo diesel, engine code AJT From May 1999 2.5 l/75 kw direct injection turbo diesel, engine codes ACV, AUF 2.5 l/111 kw direct
More informationELECTRIC CENTRAL HEATING FLOW BOILER
ELECTRIC CENTRAL HEATING FLOW BOILER EKCO.T Used product can t be treated as general communal waste. Disassembled appliance has to be delivered to the collection point of electrical and electronic equipment
More informationPANASONIC TROUBLE SHOOTING GUIDE
A General Guide To Room Style Products Pipework Pipe sizes and lengths should be as the relevant Technical Guide Both lines should be insulated No line accessories or oil traps should be fitted In cooling
More informationSERVICE MANUAL FOR 6535 SERIES TWO TON HIGH EFFICIENCY PACKAGED HEAT PUMPS
SERVICE MANUAL FOR 6535 SERIES TWO TON HIGH EFFICIENCY PACKAGED HEAT PUMPS TABLE OF CONTENTS 1. Warnings...2 2. Accessibility Of Appliance...3 3. Unit Dimensions And Specifications...3 4. Unit Specifications
More informationVOLT SPORT VOLT GOGGLES
07 08 2015-2016 VOLT SPORT VOLT GOGGLES Våra Volt goggles finns i många olika modeller och färger. Vilket gör det enkelt för dig att hitta dina egna favoriter. Alla goggles har en polykarbonat lins (PC)
More informationSHOWER WATER HEATER MODEL BS 35 / 45 / 60 BS 35 E / 45 E / 60 E OPERATION AND INSTALLATION INSTRUCTIONS
SHOWER WATER HEATER MODEL BS 35 / 45 / 60 BS 35 E / 45 E / 60 E OPERATION AND INSTALLATION INSTRUCTIONS 2 This water heater must be installed (water and electrical installation), commissioned and serviced
More informationWALL MOUNTED PACKAGE HEAT PUMPS REPLACEMENT PARTS MANUAL WH483 WH602. Contents. General Notes. Important. Description
REPLACEMENT PARTS MANUAL WALL MOUNTED PACKAGE HEAT PUMPS Models: WH421 WH483 WH602 General Notes Contents Ø Ø Revised and/or additional pages may be issued from time to time. A complete and current manual
More informationSingle sub-base valve
solenoid valves Mini-valves 10 mm Electrical connection... Mounting... Port sizes... Rated temperature... Fluid... Working pressure... Nominal flow... Pneumatic connections Voltage... Power... NC poppet
More informationInstallation Questions
Installation Questions How do I determine what type of heat I have? There may be several ways to determine what type of heat you have. First, if you can access the unit that is responsible for creating
More informationUser's Guide. CTS6000 WebControl
User's Guide CTS6000 WebControl Version 1.01, 29.06.2010 Contents Contents... 2 List of figures... 3 Introduction... 4 Introduction to CTS6000... 4 Reading instructions... 4 Quick startup... 5 Daily operation...
More information4 Alarm and info. Alarm. Yes Warning. No Information No Reset alarms > No Current list > Alarm log list > Delete alarm log > No
6. 6.1 and info (Menu 4) NB are shown in the event of unit faults or irregular operation Check the Current list (Menu 4) for alarm messages and refer to the list of alarms given at the end of these instructions.
More informationService & Parts Manual
Service & Parts Manual Portable Air Conditioner Models P09B and P2B ( Serial Number Beginning with an "A") Models P09B-A and P2B-A Portable Air conditioner-200 Svc Parts (4-200) Service Points and Flow
More informationHeating, Ventilation and Air Conditioning
Heating, Ventilation and Air Conditioning Y = 100.0 % 100 % 22.0 C Overriding Sensor Values 1800 mbar 2000 mbar Y = 100.0 79.4 % 12.0 C 31.0 C 15.0 C 27.1 C 47 % 0 % Fault Collective malfunction: Pre-flush:
More informationOverheating limit control
Pahlén electric heater Maxi Heat with digital control is a compact and effective heater for swimming pools. It consists of a glassfibre reinforced polypropylene tank containing resistance-type heating
More informationeq Top/TopMaster Air Magic by Fläkt Woods
eq Top/TopMaster Air Magic by Fläkt Woods Compact and energy efficient air handling units eq Top and TopMaster Save Energy, Economy and Environment with Fläkt Woods Energy optimization is an important
More informationCombi Unit Genius. The energy efficient Building Service Centre
Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and Heating Products Tunnel Fans Combi Unit Genius The energy efficient Building Service Centre systemair Central Building Services
More informationIntroduction to Building Automation Systems (BAS)
Introduction to Building Automation Systems (BAS) Ryan R. Hoger, LEED AP 708.670.6383 ryan.hoger@tecmungo.com Building Automation Systems Centralized controls Change scheduling for multiple HVAC units
More informationSimple Electronic Transmission
Simple Electronic Transmission Matthew Whitten Brookhaven College Created with materials from Tom Birch 1 Basically a Hydraulic System An electronic transmission is a hydraulically-operated unit that has
More informationImpact of Control System Technologies on Industrial Energy Savings
Impact of Control System Technologies on Industrial Energy Savings Priyam Parikh Industrial Assessment Center Texas A&M University Bryan P. Rasmussen Industrial Assessment Center Texas A&M University http://farolconsulting.com/?page_id=110
More informationTour of new eircom Data Centre Blanchardstown by Dervan Engineering Consultants 11 th March 2015
Tour of new eircom Data Centre Blanchardstown by Dervan Engineering Consultants 11 th March 2015 Presentation Outline Mechanical Overview Chillers and Pumps Pipework and Ancillaries In Row Cooling Units
More informationHeating and Hot Water Services Controls General Technical Specification
Construction Services Heating and Hot Water Services Controls General Technical Specification Version 1.0 Environment Heating and Hot Water Services Controls General Technical Specification Contents 1.
More informationRheem Spare Parts Manual. Commercial gas model A631265 Exterior 265L
Commercial gas model A631265 Exterior 265L Commercial gas model A631265 Exterior 265L Item Part No. Description 1 221735 Foam cover 2 221914 Anode x 3 (black) 1153mm 2 221924 Anode x 3 (blue) 1153mm 3
More informationSECTION 23 00 01 HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT
SECTION 23 00 01 HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT PART 1 - GENERAL 1.1 DESCRIPTION A. The Work specified in this Section consists of designing, furnishing and installing factory-assembled
More informationCondensing unit type EPSILON-ECHOS LE Technical information manual
Condensing unit type EPSILON-ECHOS LE Technical information manual 2 > EPSILON ECHOS Water chiller > EPSILON ECHOS /HP Reversible heat pump > EPSILON ECHOS /ST Water chiller with storage tank and pumps
More informationREAL OPERATING COST SAVINGS FROM RETRO- COMMISSIONING OPPORTUNITIES FOR SAVINGS IN ACADEMIC MEDICAL CENTERS
REAL OPERATING COST SAVINGS FROM RETRO- COMMISSIONING OPPORTUNITIES FOR SAVINGS IN ACADEMIC MEDICAL CENTERS Ken L. Hansen P.E. University of Nebraska Medical Center hansenkl@unmc.edu 402-559- 5301 402-630-
More informationsip Sanyo Modbus Guide Technical Specification Pinouts, Cable Connections & Wiring Issue 2: February 2009 Synapsys Solutions Ltd, all rights reserved
Sanyo Section : Section : Section : Section : Section : sip Modbus Guide Configuration Modbus Table Technical Specification Pinouts, Cable Connections & Wiring Alarm Fault Codes Issue : February 009 Section
More informationSpare Parts List M96A.24SM/B M96A.28SM/B
*16202390* 162.0239.0 REV5 14/04 2015 Spare Parts List M96A.24SM/B M96A.28SM/B Issue Table description Issue n. of pages Overall view 09/2008 1 C.h. return group and d.h.w. heat exchanger 09/2008 1 C.h.
More informationREMOVAL AND INSTALLATION
303-01C-1 REMOVAL AND INSTALLATION Engine Body On Special Tool(s) Adapter For 303-D043 303-D043-02 or equivalent Special Tool(s) 303-01C-1 Turbocharger Lifting Bracket 303-1266 Wrench, Fan Clutch Nut 303-214
More informationABLOY EL614 Motor lock with bolt Abloy Oy An ASSA ABLOY Group company EL614 42/52 25/35 25 22 263.5 225 38.2 17.3 3 10 2 Contents TECHNICAL DATA... 4 INSTALLATION... 5 WIRING DIAGRAM... 6 DRILLING SCHEME...
More informationBuy Karcher Parts Online: www.pressureparts.com. Need Technical Help? Call: 1-800-999-2245 email Requests to: sales@pressureparts.
Karcher Model: K 620-M * ( 59556440 ) - Parts Section:1.1 TOP PART Page 1 of 18 1 50346460 1 STRAP 2 63031250 6 SCREW 3 50670230 1 COVER 4 63031940 2 SELF-TAPPING SCREW 5 50309650 1 COVER 6 50635710 1
More informationINSTALLATION AND OPERATION MANUAL
RCS MODEL ZC4 4 ZONE HVAC INSTALLATION AND OPERATION MANUAL DCN: 141-0020-02 /0/03 INTRODUCTION The 4 Zone HVAC Controller series allows up to 4 standard electronic thermostats to independently control
More informationThe main steam enters the building in the basement mechanical room; this is where the condensate line also leaves the building.
MSV: Square Footage: 24,844 No. of Floors: 1 Year Built: 1963 Type of Use: Lounge and dining area open all night for snacks Steam Water-cooled condenser, 50-Ton York unit with a 6 cylinder-reciprocating
More informationElectric Documentation
Q L T L L T L L T L L PE L K : E E E 0// A Format SE 0 LJUNGBY SWEDEN Principle schematic 009 Page (Interlock N) (Interlock N) (Interlock L) (Interlock L) (Neutral) (Neutral) (Line) (Line) L L 0 0 L L
More informationAutomated Commissioning for Energy (ACE) Platform for Large Retail Property. Overview
Automated Commissioning for Energy (ACE) Platform for Large Retail Property $62,900 dollars of energy savings identified during the first 6 weeks Overview The ability to pull large amounts of complex data
More informationTECHNICAL SERVICE DEPARTMENT Technical Service Bulletin 1-800-432-8373. 2 Inch PowerVent LED Indicator Explanations & Troubleshooting Table
New Robertshaw control valve was introduced in May 2008 as a replacement part. See last page for troubleshooting this replacement part. All voltage inputs are 120V. All electrical connectors are Molex
More informationTopvex SX/C, Topvex TX/C. Air Handling Unit
Air Handling Unit Document in original language 131677-EN_GB 23-12-2015 A001 Contents 1 Declaration of Conformity... 1 2 Warnings... 2 3 Product information... 2 3.1 General... 2 3.2 Technical data...
More informationTECHNICAL SPECIFICATION FOR PROJECTION WELDING MACHINE (Qty. 2 Nos.)
TECHNICAL SPECIFICATION FOR PROJECTION WELDING MACHINE (Qty. 2 Nos.) 1. Requirement: Two (02) Nos. DC Type, 3 phase, 3 wire Projection Welding Machine is required for welding of ventilation M.S. / Stainless
More informationTransporter Fitting Locations No. 804 / 1
Page 1 of 10 Transporter Fitting Locations No. 804 / 1 Pin connector assigment of selected connections Overview: 1 - Ignition/starter switch -D- On steering column Connector assigment chapter 2 - Onboard
More informationFebruary 1, 2006. Performance Tested Comfort Systems Air Source Heating Pump Installation Commissioning Procedure
February 1, 2006 Performance Tested Comfort Systems Air Source Heating Pump Installation Commissioning Procedure Overview - Several measurements of air source heat pump system performance are required
More informationSMITH PLUMBING & HEATING 2012 Home Care SERVICE PLAN AGREEMENT. A. Silver Plan
SMITH PLUMBING & HEATING 2012 Home Care SERVICE PLAN A. Silver Plan AGREEMENT Priority Emergency Plumbing / Heating Repair Service: All service labor will be billed at our prevailing labor rate with no
More informationSubaru Reference. This reference contains the following information: connector pinouts. connector pinouts
Subject: Source: 1993 2010 Impreza, WRX, and Sti and 2002 07 Outback Sport ABS wiring diagrams, harness routing, and connector locations and pinouts Subaru service manuals This reference contains the following
More informationE2 Series Electric Furnaces
E2 Series Electric Furnaces Service Manual Table of Contents Electrical Requirements... 10 Codes, Specifications Requirements... 10 Connection Supply Service Wires... 10 Furnace Sequence of Operation...
More information13. Troubleshooting. Indoor unit s LED indication of Corona DC inverter unit. Indoor unit s LED indication of Alfa DC inverter unit
Troubleshooting 13. Troubleshooting Indoor unit s LED indication of Corona DC inverter unit MCAC-HTSM-2007-11 E0 E1 E2 E3 E5 E6 P0 P1 P2 P3 P5 EEPROM error outdoor communication error Zero-crossing examination
More informationConversion From Constant Flow System To Variable Flow
White Paper Conversion From Constant Flow System To Variable Flow By: Tony Egan 94.21-4/29/2010 www.armstrongintegrated.com S.A. Armstrong Limited 2010 S.A. Armstrong Limited 23 Bertrand Avenue Toronto,
More informationCONTENTS 1. IMPORTANT NOTICE 2 2. TECHNICAL SPECIFICATION 3 3. OPERATION DETAILS 4 4. WIRING DIAGRAM 11 5. EXPLOSION VIEW 12 6.
TCL WALL MOUNTED SPLIT-TYPE AIR CONDITIONERS SERVICE MANUAL No.TE051220 Models TAC-09CHSA/GI TAC-12CHSA/GI CONTENTS 1. IMPORTANT NOTICE 2 2. TECHNICAL SPECIFICATION 3 3. OPERATION DETAILS 4 4. WIRING DIAGRAM
More informationPOWER WAVE 455M/STT & (CE)
Illustration of Sub Assemblies Illustration of Sub Assemblies Illustration of Sub Assemblies Illustration of Sub Assemblies P-450 P-450 PARTS LIST FOR POWER WAVE 455M/STT & (CE) P-450-A P-450-A ILLUSTRATION
More informationspare parts Spare parts for 10 ton C-clamps Straightening > C-clamps > 10 ton
Straightening > C-clamps > 10 ton Spare parts for 10 ton C-clamps I-17475 10890 Repair kit for 10 ton NIKE CF110-310 I-AQU8 10945 Snap-on coupling male I-CF110C 10951 10 ton press cylinder 150 mm stroke
More informationPRE-LEASE SURVEY OF THE ENGINEERING SERVICES. XXXX London
PRE-LEASE SURVEY OF THE ENGINEERING SERVICES AT London Client: Clients Representative: For the Attention of: Telephone N o Site Address: London Report prepared by: Contact Name: FHP Engineering Services
More information97300 NAMUR series, 3/2 & 5/2 Indirect solenoid actuated spool valve
9700 NAMUR series, / & / > > Port size: G/, / NPT, NAMUR Interface > > Crossover-free switching > > Main application: Single and double acting actuators > > / way valve usable as / way valve > > Manual
More informationChapter 5. Components, Symbols, and Circuitry of Air-Conditioning Wiring Diagrams
Chapter 5 Components, Symbols, and Circuitry of Air-Conditioning Wiring Diagrams Objectives Upon completion of this course, you will be able to: Explain what electrical loads are and their general purpose
More informationSERVICE INSTRUCTION R410A. SPLIT TYPE ROOM AIR CONDITIONER Universal Floor / Ceiling Duct / Cassette Wall Mounted / Floor type INVERTER MULTI
SERVICE INSTRUCTION SPLIT TYPE ROOM AIR CONDITIONER Universal Floor / Ceiling Duct / Cassette Wall Mounted / Floor type INVERTER MULTI R410A Models Indoor unit Outdoor unit AB*14LBAJ AB*18LBAJ AB*F14LAT
More informationT-100-R Installation Guide
T-100-R Installation Guide Table of Contents Page 2 Overview T-100-R Z-Wave Thermostat 3-4 Installation HVAC System Setup 6 Installer Settings Menu Items 7-9 Installer Settings Summary 10-11 Wiring Standard
More informationHVAC and Lighting Control Products for Open Building Automation Systems
HVAC and Lighting Control Products for Open Building Automation Systems Distech Controls offers an extensive line of feature-rich and cost effective controllers for building automation, covering HVAC
More information14. Troubleshooting Guide
14. Guide 14.1 Refrigeration Cycle System In order to diagnose malfunctions, ensure the air conditioner is free from electrical problems before inspecting the refrigeration cycle. Such problems include
More informationExternal temperature sensors for FSC Ultrasonic Flow Meter (thermal flow measurement function)
Application: Heat quantity measurement This function calculates the heat quantity received and sent with liquid (water) in cooling and heating. Two 4-20mA inputs are available for temperature measurements.
More informationElectrical Systems - IQAN Digital Control System. IQAN Control System Components... 5.1.3
Section 5.1 Electrical Systems - IQAN Digital Control System IQAN Control System Components........................... 5.1.3 IQAN Operational Description: At Machine Startup.....................................
More informationNSN 4120-01-21 4-3692
*TM 9-4120-388-14 TECHNICAL MANUAL Operator s, Unit, Direct Support, And General Support Maintenance Manual AIR CONDITIONER, VERTICAL, COMPACT, 18,000 BTU/HR 208 VOLT, 3 PHASE, 50/60 HERTZ NSN 4120-01-21
More informationCOMPETENCY ANALYSIS PROFILE Refrigeration and Air Conditioning Systems Mechanic - Branch 1 313A
COMPETENCY ANALYSIS PROFILE Refrigeration and Air Conditioning Systems Mechanic - Branch 1 313A (All unshaded skill sets must be demonstrated/completed) PROTECT SELF AND OTHERS Identify, interpret, and
More informationCASE STUDY: NEW NCAA DIV. I COLLEGE BASKETBALL ARENA
CASE STUDY: NEW NCAA DIV. I COLLEGE BASKETBALL ARENA Stephen W. Duda, PE LEED AP Director, Mech Engineering Ross & Baruzzini, Inc. sduda@rossbar.com Acknowledgements: Ellerbe Becket, Architects, Kansas
More informationValve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)
Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv) Order code Series and function 1) Plug socket see page 5.042. MN-06-310-HN-442 Standard coil 1) 441 = 12 V DC, 4.2 W 442 = 24 V DC,
More informationNEBB STANDARDS SECTION-8 AIR SYSTEM TAB PROCEDURES
NEBB STANDARDS SECTION-8 AIR SYSTEM TAB PROCEDURES 8.1 INTRODUCTION Testing, adjusting, and balancing of HVAC systems can best be accomplished by following a series of systematic procedures. The NEBB TAB
More informationzamak nitrile rubber self-extinguishing technopolymer aluminum
PS COMBOBOX valves - Valves with compact design: valve body with integrated sub-base - High flexibility: > possibility of choosing fitting dimension (--) according to users needs > manifolds from up to
More informationzamak nitrile rubber selfestinguishing technopolymer aluminum B10 24 V DC (± 10%) holding 0,32 W, pick-up 5,5 W (25 ms) IP65 button with tool
P0 0mm COMPCT valves - threaded body and for sub-base mounting - Low standard power consumption (0,W): low power consumption electropilot B0 (standard version with LED) - Quick response times - High flow
More informationInstalling the Tracer ZN517 Unitary Controller Ordering number: 4950 0496, 4950 0596
Installing the Tracer ZN517 Unitary Controller Ordering number: 4950 0496, 4950 0596 Product overview The Tracer ZN517 controller is a field-installed, application-specific controller that provides directdigital
More information