Zehnder Focus 200. Ventilation device
|
|
|
- Magnus Lewis
- 10 years ago
- Views:
Transcription
1 Ventilation device Use The Zehnder Focus (F) 200 comfort ventilation unit was specially developed for use in demanding residential and commercial buildings. It combines maximum comfort, simple operation and high efficiency with flexible integration in building services. The Zehnder Focus (F) 200 ventilation unit moves up to 118 cfm of air at an external pressure of 0.80 "wc. Efficiency The integrated counterflow-duct heat exchanger achieves efficiencies of up to 93%. For user comfort this means: no unpleasant draft effects because the supply air is heated almost to room temperature even at temperatures around freezing. Fans Supply/extract fans are maintenance-free 230 VAC radial fans with integrated power supply and electronic switching. The fans run at a constant volume flow to keep the air volume constant at any selected fan speed. The air volume is not affected even if the filters become soiled. Supply air and extract air settings can be made separately for each fan level in increments of 1% from 35 to 118 cfm. Filters The Zehnder Focus (F) 200 ventilation unit is fitted with class G4 filters (MERV 7/8) as standard for outside air and extract air. An optional F7 pollen filter (MERV 13) is available for outside air. Installation The Zehnder Focus (F) 200 ventilation unit is characterised by its compact design. All air connections are located on the top of the unit. The unit can either be mounted on a wall or installed standing vertically on a mounting frame. As the design of the unit means that it can be supplied in a left-hand or right-hand version, installation is flexible and air ducts can be routed exactly where they are needed. Control and operation The ventilation unit is controlled and operated using the control unit, which is usually installed in the main living area of the home. The high-quality TFT touch panel with colour display and intuitive user guidance provides the means for control and operation via a touch screen and optimises communication with the ventilation unit. Maintenance To maintain the Zehnder Focus (F) 200, users simply have to change the integrated filters in the front of the unit regularly (every 6 months) and visually inspect the heat exchanger. The heat exchanger should be cleaned at least every 2 years (more often if it gets very dirty). This can be done by simply removing the heat exchanger from the device and cleaning it with soapy water. Please see the unit manual for additional servicing tasks. TS250-1
2 Frost protection The unit must be installed in a frost-free location. The Zehnder Focus (F) 200 is equipped with automatic protection against freezing. This prevents the heat exchanger from freezing should the outside air temperature drop to a very low level. If the outside air temperature or the supply air temperature at the unit drops below the threshold value, the fans will shut down temporarily. A suitable means of frost protection specifically for the unit can be connected upstream to heat the outside air (during winter). Options Humidity recovery Unit versions with a humidity heat exchanger are available as alternative options to the standard heat exchanger. The optional enthalpy exchanger (Zehnder Focus F 200) is fitted with an anti-microbial polymer membrane which is capable of recovering both heat and significant humidity. There is no risk of odours, germs or other particles being transferred during the physical process of humidity recovery. Pollen filter A large pollen filter installed in the supply air line keeps the inside of the house pollen-free and reduces the particulate, spore and germ load: breathe freely in times of increasing allergies. TS250-2
3 Benefits Comfort ventilation up to 118 cfm Heat recovery with an efficiency of up to 93% Humidity recovery with enthalpy exchanger (optional) Low power consumption thanks to the high energy efficiency of the ventilation unit (0.53 Wh /cfm) Low noise level (26 db(a) 10 ft. distance to the unit) Frost protection controller (including protection against the downstream hot water heating element icing over) Quick, safe installation and maintenance Easy operation with intuitive colour TFT touch panel Filter replacement indicator Preheater and postheater integration possible Small minimum air volume, designed specifically for residential buildings Set up for operation in conjunction with heat-producing appliances Automatic controller for external air quality sensors Article numbers L = supply air left, R = supply air right, V = preheater Luxe = advanced control Description Article number Reference number Focus 200 L Focus 200 L Enthalpy Tender text Zehnder Focus (F) 200 comfort ventilation unit with plastic counterflow-duct heat exchanger with thermal efficiency of up to 93%, optional: counterflow humidity heat exchanger with selective polymer membrane film, supply and extract fans with separate variable control in 1% increments, EC fans with constant volume flow control, maximum air volume up to 118 cfm at 0.80 "wc, H x W x D: 21.3 x 29.6 x 14.0 inch, left-hand/ right-hand design. Unit with universal controller for automatic timers or sensors, function to monitor filter running time, frost protection control, communication unit to control preheater and postheater, geothermal heat exchanger flap. Air directions The figures on the right show air directions when looking from above. A = extract air B = supply air C = exhaust air D = outside air Extract air Supply air Left-hand unit version Exhaust air Outside air Outside air Supply air Exhaust air Extract air Right-hand unit version TS250-3
4 Technical specifications Dimensions Height (inch) 21.3 Width (inch) 29.6 Depth (inch) 14.0 Specification Heat exchanger material - Plastic (counterflow-duct heat exchanger) - Polymer (humidity heat exchanger) Interior lining material Expanded polypropylene (EPP) Heat output up to 93% Weight 55.1 lb Dimensional drawing TS250-4
5 Certificates Passivhaus (passive house) Equipment Equipment Focus 200 Focus F 200 Enthalpy exchanger x Left-hand/right-hand design x x DN 125 connector x x Ready to plug in design x x TFT touch panel control unit x x Control Fan levels: STANDBY, ABSENT, LEVEL 1, LEVEL 2, LEVEL 3 Fan levels can be programmed separately for supply air and extract air for each fan level in 1% increments ( cfm) Weekly timer programme can be customised Automatic sensors (CO 2, humidity, air quality) optional with external sensor Digital ON/OFF interface (e.g. external contact for OFF) Option to connect intermittent ventilation sensor Filter running time monitoring Frost protection controller (including protection against the downstream hot water heating element icing over) Unit set up for operation in conjunction with a heat-producing appliance Error messages Running time monitoring (separate for fans/unit) Power consumption in standby < 1 W Options (with add-on module) Triggering of an external defroster heater Triggering of a heating circuit or air reheating register Triggering of an electric actuating valve on the geothermal heat exchanger TS250-5
6 TS250-6
7 Technical specifications Sound, supply air Sound power at the supply air connection at a distance of 0 ft. Ventilation unit Volume flow Type cfm 125 Hz 250 Hz 500 Hz 1000 Hz 2000 Hz 4000 Hz 8000 Hz Focus Focus Sound, extract air Sound power at the extract air connection at a distance of 0 ft. Ventilation unit Volume flow Type cfm 125 Hz 250 Hz 500 Hz 1000 Hz 2000 Hz 4000 Hz 8000 Hz Focus Focus TS250-7
8 CDE-FLYERTS250, V0112, en, subject to changes Zehnder America, Inc. 540 Portsmouth Ave. Greenland, NH USA T Toll Free: F [email protected]
06150 PORVOO, FINLAND Pelican eco ED(D), Pelican eco EDE(D), Pelican eco EDW(D), Pelican eco EDX(D)
Certificate Certified Passive House Component For cool, temperate climates, valid until 31 December 2013 Passive House Institute Dr. Wolfgang Feist 64283 Darmstadt GERMANY Category: Manufacturer: Heat
How To Get A Passive House
Certificate Certified Passive House Component For cool, temperate climates, valid until 31 December 2015 Passive House Institute Dr. Wolfgang Feist 64283 Darmstadt GERMANY Category: Manufacturer: Product
CE6500 Energy Recovery Ventilator
ADVANCED COMMERCIAL Energy Recovery Ventilator PRODUCT SPECIFICATIONS & TECHNICAL DATA Features NOMINAL CAPACITY 5500-7000 CFM CASING Double-wall cabinet White exterior paint, -gauge galvanized steel -gauge
Comfosystems Systems with heat recovery for a comfortable indoor climate
Comfosystems Systems with heat recovery for a comfortable indoor climate always around you Heating Cooling Fresh Air Clean Air Zehnder everything you need to create a comfortable, healthy and energy-efficient
Air conditioning unit Saphir vario. 2. Product information for the new Truma air conditioning unit. Comfort on the move
Air conditioning unit 2. Product information for the new Truma air conditioning unit October 2006 Edition Comfort on the move Air conditioning systems Manoeuvring systems Energy systems Heating systems
New Deluxe Wall Mounted Heat Pump Series EXTERIOS
New Deluxe Wall Mounted Heat Pump Series EXTERIOS May 2013 New Deluxe Wall Mounted Heat Pump Series Panasonic Adding New Air Conditioner Lineup Setting Another Mile Stone in the US Ductless Split History
Innovent LASER Packaged Fresh Air Conditioning Units
LASER Latent And Sensible Energy Reduction Latent And Sensible Energy Reduction For Outside Air Innovent LASER Packaged Fresh Air Conditioning Units Innovent LASER units provide both sensible and latent
Material test chamber with mechanical convection
FP series 400 Material test chambers Material test chamber with mechanical convection A BINDER material test chamber with mechanical convection of the FP series provides reliably short drying times and
01-3 0000-00 6810-20 AIR CONDITIONING SYSTEM 1. FFH SPECIFICATION AIR CONDITIONING SYSTEM RODIUS 2004.09
0000-00 01-3 6810-20 1. FFH SPECIFICATION 01-4 0000-00 2. SYSTEM LAYOUT AND COMPONENTS 0000-00 01-5 01-6 0000-00 3. FFH GENERAL INFORMATION The system is to increase the coolant temperature quickly by
Installation and maintenance instructions. Danfoss Vent
Installation and maintenance instructions Danfoss Vent 1 Unit design... 2 2 Project planning and installation instructions... 3 2.1 Ventilation...3 2.2 Piping installation....3 2.3 Condensation line...4
Combi Unit Genius. The energy efficient Building Service Centre
Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and Heating Products Tunnel Fans Combi Unit Genius The energy efficient Building Service Centre systemair Central Building Services
UR...3 URX CF...7 URHE CF...11. Heat recovery unit. Heat recovery unit with refrigerant circuit(442-1947 cfm)
UR...3 Heat recovery unit URX CF...7 Heat recovery unit with refrigerant circuit(442-1947 cfm) URHE CF...11 High efficiency heat recovery unit with refrigeration circuit(588-1942 cfm) UR Heat recovery
Visions become real. Temperature control and cooling systems. The innovative and reliable solution
Temperature control and cooling systems The innovative and reliable solution With our PulseTemp equipment you have the option of up to 72 cooling circuits in the impulse cooling, temperature control, temperature
RKE. Heat recovery unit. heat recovery unit RKE. from 200 to 6800 m 3 /h. General features
RKE Heat recovery unit from 200 to 6800 m 3 /h General features RKE heat recovery units are suitable for residential and commercial applications and offer a real energy saving in forced ventilation plants,
Under sill units. Type FSL-B-ZAS
.1 X X testregistrierung Under sill units Type, heat recovery Centrifugal fan Adaptive heat recovery damper HYGIENISCH GETESTET V DI 022 Tested to VDI 022 Secondary air unit for supply air and extract
Heating oven with mechanical convection
FD series 53 Drying ovens / Heating ovens Heating oven with mechanical convection A BINDER FD series heating oven is always used when fast drying and sterilization is required. Thanks to its fully homogeneous
Incubator with mechanical convection
BF series 400 Incubators and cooling incubators Incubator with mechanical convection The BINDER incubator of the BF series with mechanical convection is suitable for all gentle incubation applications,
Bring the fresh in. Dedicated Outside Air Systems
Bring the fresh in. Dedicated Outside Air Systems The inside story on outside air. On average, we breathe in 3,400 gallons of air each day. Ambient indoor air pollution is a major problem, affecting health
User Manual: C100. 9052 Long Point Houston, TX 77055 888.827.1675 [email protected] Facebook.com/CoolAZone Twitter.com/CoolAZone
User Manual: C100 9052 Long Point Houston, TX 77055 888.827.1675 [email protected] Facebook.com/CoolAZone Twitter.com/CoolAZone w w w. c o o l a z o n e. c o m Table of Contents Table of Contents & How
ComfoAir 550 Luxe Manual
ComfoAir 550 Luxe Manual All rights reserved. This manual has been compiled with the utmost care. The publisher cannot be held liable for any damage caused as a result of missing or incorrect information
FOXAIR 60/50 ALL MODELS
FOXAIR 60/50 ALL MODELS OPERATION AND SERVICE MANUAL UNIT WEIGHT - ALL MODELS APPROX. 300 POUNDS FOXTRONICS, INC. 38 L x 28 W x 24 H Love Field-Dallas TX MADE IN THE USA 3448 West Mockingbird Lane Dallas,
eq Top/TopMaster Air Magic by Fläkt Woods
eq Top/TopMaster Air Magic by Fläkt Woods Compact and energy efficient air handling units eq Top and TopMaster Save Energy, Economy and Environment with Fläkt Woods Energy optimization is an important
Top Technology for Industry, Agriculture, Business and Communities
Top Technology for Industry, Agriculture, Business and Communities CHP The Technology with a Potential for Saving Energy Combined Heat and Power (CHP) is a highly efficient technology for the conversion
REMOTE CONTROL MANUAL
REMOTE CONTROL MANUAL ENGLISH CONTENT PRECAUTIONS...1-2 USING THE REMOTE CONTROL UNIT...3 OPERATION...4-9 Thank you for purchasing our Room Air Conditioner. Before using your air-conditioner, please read
Duplexvent DV72 EC So light, so slim it fits inside a 600mm cupboard
Duplexvent DV72 EC So light, so slim it fits inside a 600mm cupboard Duplexvent DV72 EC MVHR is designed to provide constant volume ventilation levels to exceed the latest Building Regulations 2010. The
ComfoAir 350 Luxe User Manual
ComfoAir 350 Luxe User Manual All rights reserved. This manual has been compiled with the utmost care. The publisher cannot be held liable for any damage caused as a result of missing or incorrect information
USER S MANUAL HSC-24A
AIRREX AIR CONDITIONER USER S MANUAL HSC-24A Thank you for purchasing an AIRREX AIR CONDITIONER. BEFORE operation please read this user s manual carefully. Keep this manual readily available. It is ESSENTIAL
Heating / Ventilation / Air Conditioning Room Climate Control with ABB i-bus KNX
Heating / Ventilation / Air Conditioning Room Climate Control with ABB i-bus KNX Content Heating / Ventilation / Air Conditioning 3 The Right Room Climate 4 Optimised Energy Efficiency and well-being Room
FTXS. Wall Mount Heat Pump or Cooling Only
FTXS Wall Mount Heat Pump or Cooling Only EXPERTISE AND INNOVATION Daikin s FTXS SkyAir systems feature streamlined, wall mounted indoor units paired with quietly compact outdoor units. Available in both
HEATER, AIR CONDITIONING AND VENTILATION
55-1 GROUP 55 HEATER, AIR CONDITIONING AND VENTILATION CONTENTS GENERAL DESCRIPTION 55-2 HEATER AND AIR CONDITIONING SYSTEM 55-4 HEATER CONTROL 55-6 A/C-ECU 55-7 A/C COMPRESSOR 55-9 CONDENSER 55-9 DUCT
HVAC Processes. Lecture 7
HVAC Processes Lecture 7 Targets of Lecture General understanding about HVAC systems: Typical HVAC processes Air handling units, fan coil units, exhaust fans Typical plumbing systems Transfer pumps, sump
squrboxbox heat recovery squrboxbox I technical information
heatrecoveryrange heat recovery squrboxbox I technical information squrboxbox Low depth high performance Only 350mm deep & up to 430l/s, providing the most effective low depth solution. Quietest solution
SHOWER WATER HEATER MODEL BS 35 / 45 / 60 BS 35 E / 45 E / 60 E OPERATION AND INSTALLATION INSTRUCTIONS
SHOWER WATER HEATER MODEL BS 35 / 45 / 60 BS 35 E / 45 E / 60 E OPERATION AND INSTALLATION INSTRUCTIONS 2 This water heater must be installed (water and electrical installation), commissioned and serviced
B.IQ push button 3-5gang with room thermostat and display V2, flush-mounted 7566359x, 7566459x, 7566559x
B.IQ push button 3-5gang with room Product name: Design: ETS search path: B.IQ push button 3-, 4-, 5gang with room thermostat and display V2 Flush-mounted Push button / B.IQ / B.IQ push button xgang with
How To Make Your House Breathe
RENEWABLES VENTILATION UNITS Nothing lost plenty of healthy fresh air gained Innovative ventilation units that offer healthy indoor air and significantly lower energy bills 04 2015 STIEBEL ELTRON is full
USER MANUAL HRV CONSTRUCTO 2.0ES* HRV CONSTRUCTO 1.5ES* * THESE PRODUCTS EARNED THE ENERGY STAR BY MEETING STRICT ENERGY EFFICIENCY
USER MANUAL RESIDENTIAL USE ONLY VB0175 HRV CONSTRUCTO 2.0ES* HRV CONSTRUCTO 1.5ES* * THESE PRODUCTS EARNED THE ENERGY STAR BY MEETING STRICT ENERGY EFFICIENCY GUIDELINES SET BY NATURAL RESOURCES CANADA
ECOCIAT. Domestic hot water heat recovery unit
Heat recovery unit Domestic hot water High energy efficiency with R410A Compact and quiet Scroll compressors Brazed-plate heat exchangers Heating Heat recovery ENVIRONMENTALLY HFC R410A PROTECTION DE FRIENDLY
Heating oven with mechanical control
ED series 53 Drying ovens / Heating ovens Heating oven with mechanical control The strength of the BINDER ED series heating oven: routine drying and sterilization applications up to 300 C (572 F). Thanks
saving energy in comfort Factsheet Recair Enthalpy
saving energy in comfort Factsheet Recair Enthalpy Introduction Enthalpy Exchanger The enthalpy exchanger is able to transfer both sensible heat and latent heat (moisture) from the cooled to the heated
Electronic Control Devices The European Product Catalogue 2007
FX07 Field Controller (1/4) FX07 Field Controller Display Model Dimensions in mm (inches) The FX07 is a terminal unit controller in the Facility Explorer range of products. The controller is designed specifically
Residential/Commercial Gas Condensing High Efficiency Tankless Water Heaters
Residential/Commercial Gas Condensing High Efficiency Tankless Water Heaters FEATURES ULTRA-LOW NOx CONDENSING TECHNOLOGY PROVIDES UNPRECEDENTED 0.95 ENERGY FACTOR DURABLE HEAT EXCHANGER Primary Heat Exchanger
Important Safeguards
Table of Contents Important Safeguards...2 Product Layout...3 Preparing for Use...4 Air-conditioning without installation...4 Air-conditioning with installation...5 Control Panel...6 Operating from the
SECTION 23 00 01 HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT
SECTION 23 00 01 HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT PART 1 - GENERAL 1.1 DESCRIPTION A. The Work specified in this Section consists of designing, furnishing and installing factory-assembled
Itho Products for Hot and Boiling water. product-
Itho Products for Hot and Boiling water product- 2 This booklet provides additional information on the range of hot and boiling water appliances by Itho. The data will allow you to determine which product
The Benefits Really Add Up
Unico, Inc. 7401 Alabama Ave. St. Louis, MO 63111 Unico, Inc. manufacturing plant and sub-assembly plant +1 800 527 0896 +1 314 481 9000 www.unicosystem.com Unico, Inc. is the leader in Small Duct High
DUCT TYPE AIR CONDITIONER
OPERATING MANUAL OPERATING MANUAL BEDIENUNGSANLEITUNG MODE D EMPLOI MANUAL DE FUNCIONAMIENTO MANUALE DI ISTRUZIONI ΕΓΧΕΙΡΙ ΙΟ ΛΕΙΤΟΥΡΓΙΑΣ MANUAL DE INSTRUÇÕES AIR CONDITIONER DUCT TYPE English Deutsch
IH 17025 E Sigma Island 90
INSTRUCTIONS FOR USE Kitchen extractor hood Type: IH 17025 E Sigma Island 90 Dear Customer!! You are now a user of the newest generation kitchen extractor hood type IH 17025 E Sigma Island 90. This hood
Installation, operation and maintenance manual TX 35A
Installation, operation and maintenance manual TX 35A Rev.10 may 2012 Page 1 of 18 1.0.0 Table of contents INSTALLATION, OPERATION AND MAINTENANCE MANUAL...1 1.0.0 TABLE OF CONTENTS...2 2.0.0 ILLUSTRATIONS...2
Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw
4 937 DESIO Current valve for AC 24 V pulse/pause control of electrical loads up to 30 kw SEA45.1 Use The current valve is used for the control of electric heating elements in heating, ventilation and
NAVIEN AMERICA INC. 17855 FITCH AVENUE
Navien America Inc. Specification Details for the Navien models: CC-240 CC-240A For Potable Water Heating and Space Heating NAVIEN AMERICA INC. 17855 FITCH AVENUE IRVINE, CALIFORNIA, USA 92614 Toll Free:
Dehumidifier D 850E. - Instruction manual version 02
Dehumidifier D 850E - Instruction manual version 02 Content 1. Description of dehumidifier 1.1. General data 1.2. Technical data 2. Operation and usage 2.1. Usage 2.2. Location and installation 2.3. Preparing
Ventilation Solutions Fresh Air Solutions for Ductless Heating & Cooling. fantech
Ventilation Solutions Fresh Air Solutions for Ductless Heating & Cooling 2 Ductless Ventilation & Fresh Air Solutions We can fill your home with healthy, fresh air Indoor Air Pollution is real, and it
KU DESIGN GUIDELINES APPENDIX XVI RECOMMENDED BAS I/O CONTROL POINTS BY EQUIPMENT / SYSTEM
KU DESIGN GUIDELINES APPENDIX XVI RECOMMENDED BAS I/O CONTROL POINTS BY EQUIPMENT / SYSTEM AIR HANDLING UNITS... 1 CHILLERS... 2 COOLING TOWERS... 2 CLOSED LOOP COOLERS... 2 MISCELLANEOUS SUPPLY FANS...
NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS
NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS ELECTRICAL SAFETY This appliance is for indoor use only. Always turn off the unit and unplug
PORTABLE AIR CONDITIONER
PORTABLE AIR CONDITIONER MAC 7500 Owner s Manual Air Conditioner Dehumidifier Oscillating Fan Please read this owner s manual carefully before operating the unit. POWERED BY 66126113.p65 17 INTRODUCTION
Automatic air conditioning system
Automatic air conditioning system Air outlets and fan speed are automatically adjusted according to the temperature setting. With navigation system Owners of models equipped with a navigation system should
On/off room thermostats range. On/off V30 range. Master/slave PI V200 range. V3000 KNX networked PID range
Electromechanical controls Air control Water control On/off room thermostats range On/off room thermostats range Electronic controls Air control On/off V30 range On/off V30 range Water control Master/slave
Roof Top Air Conditioner INSTALLATION AND OPERATING INSTRUCTIONS
Roof Top Air Conditioner INSTALLATION AND OPERATING INSTRUCTIONS Ducted System RECORD THIS UNIT INFORMATION FOR FUTURE REFERENCE: Model Number: Serial Number: Date Purchased: This manual must be read and
The compact unit series
The compact unit series The easy way to maintain a good climate i High, efficient energy recovery with an efficiency of 80 90 % i Energy-saving fan motors utilising EC technology for minimal energy consumption
RRV934. Multi-controller. Synco living
s 2 709 Synco living Multi-controller RRV934 RF-based multi-controller For precontrol of up to 2 room groups For control of ventilation plant with up to 3 stages RF communication based on KNX standard
Energy Efficiency HOSPITALITY. www.energia.ie
Energy Efficiency HOSPITALITY www.energia.ie Your chance to reduce your business energy usage by as much as 20%! 20% is a significant figure and reducing your energy bill by this amount could make a real
Basic Technology Series
Basic Technology Series Fundamentals of Car Air Conditioning 2007 Air Conditioning #003 The Rear Cooler Construction Fan Fan Filter Figure A : Trunk Figure B : Overhead Dual Air-Conditioner In This Issue
Airline. small air handlers and extract fan units. VES Airline part of a complete range of innovative, flexible products from the HVAC experts
Lo w p r o f i l e small air handlers and extract fan units Duties to 0.55m 3 /sec Available with the Electroline fitted control panel Ceiling void friendly - unit heights from 190mm to 350mm Airline VES
Dienstleistung. Certification as "Quality Approved Passive House" Criteria for Residential-Use Passive Houses
Passiv Haus Institut Passivhaus Dienstleistung GmbH Dr. Wolfgang Feist Rheinstr. 44/46 Rheinstr. 44/46 D-64283 Darmstadt D-64283 Darmstadt www.passiv.de www.passivhaus-info.de Certification as "Quality
Thermostat with display
H/LN4691-0 674 59-64170 Thermostat with display RA00118AA_I-01PC-13W39 www.homesystems-legrandgroup.com Thermostat with display Contents Thermostat with display 1 Introduction 4 1.1 Warnings and recommendations
USER S GUIDE For all Packaged Systems (Air Conditioners and Heat Pumps)
USER S GUIDE For all Packaged Systems (Air Conditioners and Heat Pumps) WA & WL - Series Air Conditioners WH & SH - Series Air Source Heat Pumps IH - Series Air Source Heat Pumps DATE: 02-21-12 QA - Series
USERS GUIDE. LOGIC Combi 24, 30, 35. For installation guide see reverse of book
USERS GUIDE LOGIC Combi 24, 30, 35 For installation guide see reverse of book When replacing any part on this appliance, use only spare parts that you can be assured conform to the safety and performance
Low Cost. Lower Energy Costs. Higher Efficiency.
HI-E DRY dehumidifiers remove two to three times more water per kilowatt hour of electricity than conventional dehumidifiers. Low Cost. Lower Energy Costs. Higher Efficiency. Therma-Stor designed an efficient,
USER S MANUAL. Duct Type Series. Free Joint Multi Air Conditioner (Cooling and Heating) FUEA Series E S F I P D G DB98-29565A(1) ENGLISH ESPAÑOL
USER S MANUAL Duct Type Series MH MH FEEA Series FUEA Series ENGLISH ESPAÑOL PORTUGUÊS E HNIKA DEUTSCH ITALIANO FRANÇAIS Free Joint Multi Air Conditioner (Cooling and Heating) E S F I P D G DB98-29565A(1)
JAWAHARLAL NEHRU UNIVERSITY
School of Biotechnology JAWAHARLAL NEHRU UNIVERSITY New Delhi 110 067 Tender No. JNU/SBT/DBT-BUILDER/Data Centre/2015-16 Sealed Quotation for the establishment of a Data Centre for High-End Computational
Lesson 36 Selection Of Air Conditioning Systems
Lesson 36 Selection Of Air Conditioning Systems Version 1 ME, IIT Kharagpur 1 The specific objectives of this chapter are to: 1. Introduction to thermal distribution systems and their functions (Section
Please read this owner s Manual carefully before operating the unit. - Cooling - Heating - Dehumidifying - Fan
Please read this owner s Manual carefully before operating the unit. - Cooling - Heating - Dehumidifying - Fan TABLE OF CONTENTS INTRODUCTION 2 IMPORTANT SAFEGUARDS...2 PACKAGE CONTAINS..2 NAMES OF PARTS.3
Subpart 1. Installation. All plumbing systems must be. installed and tested according to this chapter and chapter 4715,
4658.4500 PLUMBING SYSTEMS; NEW CONSTRUCTION. Subpart 1. Installation. All plumbing systems must be installed and tested according to this chapter and chapter 4715, the Minnesota Plumbing Code. Subp. 2.
Design Guide. Retrofitting Options For HVAC Systems In Live Performance Venues
Design Guide Retrofitting Options For HVAC Systems In Live Performance Venues Heating, ventilation and air conditioning (HVAC) systems are major energy consumers in live performance venues. For this reason,
Failure code manual. content
Failure code manual content 一 wall split AC series 2 二 floor standing AC series. 4 三 portable AC series.. 5 四 dehumidifer 6 五 DC inverter single split series...7 六 DC inverter multi-split series 10 1 一
94122E-05 2005-10 FLEXIT L4 X/TT L7 X/TT. User Manual. Air Handling Unit Loft Models with Heat Recovery
94122E-05 2005-10 FLEXIT L4 X/TT User Manual L7 X/TT Air Handling Unit Loft Models with Heat Recovery Contents 1 Important Safety Instructions...3 2 Method of Operation - System...3 3 Operation - Control...4
Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W
MODE ALARM Portable Air Conditioner OWNER S MANUAL Read these instructions before use 8 Model: MF08CESWW Voltage rating: 115V~60Hz Power rating : 800W Customer Support : 1-800-474-2147 For product inquiries
york air-conditioning products Residential & VRF News 2015
york air-conditioning products Residential & VRF News 2015 york air-conditioning products Catalogue Content Split Systems Pag. High wall High Efficiency Inverter YWHJZH 09 to 24 K 6 High wall Inverter
INPUT/OUTPUT MODULE CONVERT INPUTS AND OUTPUTS TO WIRELESS
VMC A4 INPUT/OUTPUT MODULE CONVERT INPUTS AND OUTPUTS TO WIRELESS PRODUCT DATA SHEET FEATURES RF to 0-10 VDC out, analogue or PWM Maximal 3 digital inputs to RF RF communication with other equipment Wireless
MODEL: DV72. Mechanical Ventilation with Heat Recovery Installation Instructions and User Manual. Configuration Left Hand Right Hand
9041381- Issue 6 4/11 MODEL: DV72 Mechanical Ventilation with Heat Recovery Installation Instructions and User Manual Commissioning Data: to be completed by the installer Date of installation: Configuration
26 AND 27 SLEEVES. IDEAL for NEW CONSTRUCTION, RETROFITS and REMODELS.
T H R U - T H E - W A L L A I R C O N D I T I O N E R S 26 AND 27 SLEEVES. IDEAL for NEW CONSTRUCTION, RETROFITS and REMODELS. W A L L M A S T E R T H R U - T H E - W A L L A I R C O N D I T I O N E R
EASYAIR flat THE COMPACT WAY TO A COMFORTABLE CLIMATE.
EASYAIR flat THE COMPACT WAY TO A COMFORTABLE CLIMATE. LIFE IN PURSUIT OF QUALITY FROM THE VILLAGE FORGE TO A GLOBAL CORPORATION The Directors of AL-KO KOBER SE (from right to left): Stefan Kober (CEO),
Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW
Portable Air Conditioner OWNER S MANUAL Read these instructions before use 8 Model: MN12CES / MN10CESWW Voltage rating: 120V~60Hz Power rating : 1100W (MN12CES) Power rating : 900W (MN10CESWW) Customer
Pool Dehumidification Basics
Copyright 2009 Wescor. All rights reserved. Permission granted to reproduce for personal and educational use only. When energy costs were low, many pool owners considered only first cost when choosing
Liebert Hiross HPW The High Performance Wallmount Cooling Solutions for Telecom Mobile Remote Access Nodes
Precision Cooling for Business-Critical Continuity Liebert Hiross HPW The High Performance Wallmount Cooling Solutions for Telecom Mobile Remote Access Nodes We re Emerson Network Power, backed by Emerson,
EFA PSBP. Natural Ventilation Strategy. Introduction. 1.1 Relevant legislation. 1.1.1 The Building Regulations 2010
EFA PSBP Natural Ventilation Strategy Introduction The Baseline Designs Project will provide scheme design details for a number of Primary and Secondary School Exemplars. For the purposes of setting a
COMPUTHERM Q7 Programmable, digital room thermostat. Operating Instructions
COMPUTHERM Q7 Programmable, digital room thermostat Operating Instructions GENERAL DESCRIPTION OF THE THERMOSTAT The COMPUTHERM Q7 type switched-mode room thermostat is suitable to regulate the overwhelming
Air Conditioner Water Heater - A Product of HotSpot Energy LLC
Air Conditioner Water Heater - A Product of HotSpot Energy LLC PLEASE READ THIS BEFORE YOU INSTALL THE UNIT 1. This air conditioner must be installed and/or repaired by a qualified technician. If you perform
CRAC Precision climate control units for data centres
CRAC Precision climate control units for data centres 2 Rittal Computer Room Air Conditioner The whole is more than the sum of its parts The same is true of Rittal The System. With this in mind, we have
Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W
Portable Air Conditioner OWNER S MANUAL Read these instructions before use Model: MM14CCS Customer Support : 1-800-474-2147 Voltage rating: 115V~60Hz Power rating : 1400W For product inquiries or support
HIGH EFFICIENCY RTU. www.reznorhvac.com HIGH EFFICIENCY, PACKAGED SPACE CONDITIONING. DX System IEER> 13.2 Gas Heat Efficiency > 92% Capacities Tons
Capacities 10-25 Tons 100-400 MBH HIGH EFFICIENCY, PACKAGED SPACE CONDITIONING DX System IEER> 13.2 Gas Heat Efficiency > 92% HIGH EFFICIENCY RTU 30-120 kw 3,000-11,550 CFM Comfort Comfort is determined
Flexit air handling unit K2 R
Flexit air handling unit K2 R with integrated kitchen hood PATENTED The quietest on the market Modern design Energy-efficient Installation in the kitchen A FOR A HEALTHY ENVIRONMENT Requirement-controlled
ABB i-bus EIB / KNX Analogue Input AE/S 4.2
Product Manual ABB i-bus EIB / KNX Analogue Input AE/S 4.2 Intelligent Installation Systems This manual describes the functionality of Analogue Input AE/S 4.2. Subject to changes and errors excepted. Exclusion
air conditioners how to choose a cooling system
air conditioners how to choose a cooling system taking responsibility As an individual, your efficient use of energy brings benefits such as lower bills, improved comfort levels in your home and a reduced
How To Use A Power Supply On A Powerline 2.2 (Ai)
KNX/EIB Product documentation Issue: 05.08.2010 629x1220 Push button sensor 3 comfort 1-gang Push button sensor 3 comfort 2-gang (1+1) Push button sensor 3 comfort 3-gang Push button sensor 3 comfort 4-gang
FLEXIT S4 R S6 R S7 R
94111E-05 2005-10 FLEXIT S4 R S6 R S7 R User Manual Air Handling Unit Cabinet Models with Heat Recovery - Rotor Contents 1 Important Safety Instructions... 3 2 Method of Operation - System... 3 2.1 Heating
HEAVY DUTY STORAGE GAS
Multi-Fin flue technology Flue damper saves energy Electronic controls HEAVY DUTY STORAGE GAS Dependability The Rheem heavy duty gas range is the work horse of the industry having proved itself over many
ACS-30-EU-EMDR-10-MOD
Multi-application heat tracing Control and Monitoring in commercial and residential buildings Roof & Gutter de-icing sensor module Technical Information Approvals Module IP rating Ambient operating temperature
INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE
INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE Fujitsu General realizes considerable energy saving operations by the Heat pump heating system using the ambient
AN500T, AN1000, AN1000T, AN1500, AN1500T AN2000, AN2000T
Product Instruction Manual Accona AN500T, AN1000, AN1000T, AN1500, AN1500T AN2000, AN2000T Panel heater v16.5/5 Version 3.2 Jan 2015 Contents 1. Important safety points 2. Installation 2.1. Wall mounting