GOLD CX 120 eff.var./cap.var. 1

Size: px
Start display at page:

Download "GOLD CX 120 eff.var./cap.var. 1"

Transcription

1 SE/G.ELCX20E.502 GOLD CX 20 eff.var./cap.var. Med styrenhet (i undre plan)/with control unit (in lower level) Säkerhetsbrytare/ huvudströmbrytare/ Safety switch/ main switch IQnavigator Temperaturgivare, tilluft/ Supply air temperature sensor * Fläkt 2:/ Fan 2: N L Eftervärme/ Reheater us-kontakter/ us connections *M * Fläkt 2:2/ Fan 2:2 *M Filter/ Filter 4 Fläkt/ Fan 2 * Fläkt 2:3/ Fan 2:3 *M

2 SE/G.ELCX20E.502 GOLD CX 00/20- Utan styrenhet (i övre plan)/without control unit (in upper level) Fläkt :3/ Fan :3 * *L Fläkt :2/ Fan :2 * *L Filter/ Filter 3 Kabel/Cable Till plint/to terminal block, 2, 3 2 4, 5, 6 3 7, 8, 9 Fläkt :/ Fan : * Fläkt/ Fan *L Se nedan/ See below C Från ellåda i undre plan/ From el. cubicle in lower level Tilluft i övre plan med fläkt till vänster om visad ellåda/ Supply air in upper level, fan to the left of shown el. cubicle Tilluft i övre plan med fläkt till höger om visad ellåda/ Supply air in upper level, fan to the right of shown el. cubicle SENSOR 2 SENSOR 3 SENSOR SENSOR 4 SENSOR 2 SENSOR 3 SENSOR SENSOR 4 Komm.kabel tryckgivare/ Comm. cable pressure sensor Temp.givare före batteri/ Temp. sensor before coil Utgående komm.kablar, märkta lika som kabeladapter/ Comm. cable out, marked as cable adapter Komm.kabel tryckgivare/ Comm. cable pressure sensor Temp.givare före batteri/ Temp. sensor before coil Utgående komm.kablar, märkta lika som kabeladapter/ Comm. cable out, marked as cable adapter Frånluft i övre plan med fläkt till vänster om visad ellåda/ Exhaust air in upper level, fan to the left of shown el. cubicle Frånluft i övre plan med fläkt till höger om visad ellåda/ Exhaust air in upper level, fan to the right of shown el. cubicle SENSOR 3 SENSOR 3 SENSOR 4 SENSOR 4 Fuktgivare före batteri, Komm.kabel tryckgivare/ before coil, Comm. cable pressure sensor Utgående komm.kablar, märkta lika som kabeladapter/ Comm. cable out, marked as cable adapter Fuktgivare före batteri, Komm.kabel tryckgivare/ before coil, Comm. cable pressure sensor Utgående komm.kablar, märkta lika som kabeladapter/ Comm. cable out, marked as cable adapter 2

3 SE/G.ELCX20E.502 P: GOLD CX Fläktplacering, högerutförande/ Fan rrangement, right-hand version Temperaturgivare / Temperature sensor Styr / Control Temperaturgivare / Temperature sensor Fläktplacering, vänsterutförande/ Fan rrangement, left-hand version Styr / Control 3

4 SE/G.ELCX20E.502 Fläktplacering 2, högerutförande/ Fan rrangement 2, right-hand version Temperaturgivare / Temperature sensor Temperaturgivare / Temperature sensor Styr / Control Fläktplacering 2, vänsterutförande/ Fan rrangement 2, left-hand version Styr / Control Temperature sensor3 4

5 SE/G.ELCX20E.502 Fläktplacering 4, tilluft uppe/ Fan rrangement 4, supply air in upper level Temperaturgivare / Temperature sensor Temperaturgivare / Temperature sensor Styr / Control Fläktplacering 4, tilluft nere/ Fan rrangement 4, supply air in lower level Temperature sensor3 Styr / Control 5

6 SE/G.ELCX20E.502 Fläktplacering 5, tilluft uppe/ Fan rrangement 5, supply air in upper level Temperaturgivare / Temperature sensor Temperaturgivare / Temperature sensor Styr / Control Fläktplacering 5, tilluft nere/ Fan rrangement 5, supply air in lower level Temperature sensor3 Styr / Control 6

7 SE/G.ELCX20E.502 : GOLD RX/PX/CX/SD 08/ eff.var./cap.var. 2, 2-20 Gulgrön/ Yellow green W V U UVWPE LL2L3PE run/ rown Svart/lack Grå/Grey Gulgrön/ Yellow green Motorkabel/ Motor cable Styrkabel/ Control cable Kraftkabel/ Power supply cable 7

8 SE/G.ELCX20E.502 E: GOLD RX/PX/CX 08/ eff.var./cap.var. 2, 2-20 Inkoppling av kraftkablar på motorskyddsbrytare/ To wire power supply cables to the protective motor switch ggregat stl./ Inställning Inställning HU size motorskyddsbrytare motorskyddsbrytare fläktar ()/ cirkulationspump rörkopplingsenhet ()/ Setting, protective Setting, protective motor switch motor switch fans () pipework package circulation pump () , ,5 2,35 run/rown Svart/lack Grå/Grey Gulgrön/Yellow green F: GOLD CX G: GOLD CX GRUNDFOS 8

9 SE/G.ELCX20E.502 L: GOLD RX/PX/CX/SD 20 Pos/Pos. Pos/ Pos. / Fläkt :/ Fan : / Fläkt :2/ Fan :2 Styrkablar med snabbkoppling/ Control cables with quick connector Tryckgivare 6 6 sida / Pressure sida transducer Side 6 6 CC5/CC5 Pos/ Pos. / Fläkt :3/ Fan :3 6 6 M: GOLD RX/PX/CX/SD 20 Pos/Pos. Pos/ Pos. / Fläkt 2:/ Fan 2: / Fläkt 2:2/ Fan 2:2 Styrkablar med snabbkoppling/ Control cables with quick connector CC6/CC6 Tryckgivare sida 2/ Pressure transducer Side 2 Pos/ Pos. / Fläkt 2:3/ Fan 2:

10 SE/G.ELCX20E

FP1-H GOLD CX 35-40. Fläkt 2/ Fan 2 *E *F *G. Fläkt 1/ Fan 1 SE/GB.ELCX3540.060501. Temperature sensor 4. Temperaturgivare 4/ Humidity sensor

FP1-H GOLD CX 35-40. Fläkt 2/ Fan 2 *E *F *G. Fläkt 1/ Fan 1 SE/GB.ELCX3540.060501. Temperature sensor 4. Temperaturgivare 4/ Humidity sensor *B GOLD CX 35-40 Temperaturgivare tilluft/ Temperature sensor, in supply air Fläkt / Fan Filter/ Filter Fläkt/Fan 3 *J FP-H *I T 3 T ST *E *F *G *H Cirkulationspump/ Circulation pump Ventilställdon/ Valve

More information

GOLD SD 11 effektvariant 2, 12

GOLD SD 11 effektvariant 2, 12 GOLD SD effektvariant 2, 2 Med styrenhet/with control unit us-kontakter/ us connections N L Eftervärme/ Reheater Temperaturgivare för densitetskorrigerat luftflöde./ Temperature sensor for densitycorrected

More information

PANASONIC TROUBLE SHOOTING GUIDE

PANASONIC TROUBLE SHOOTING GUIDE A General Guide To Room Style Products Pipework Pipe sizes and lengths should be as the relevant Technical Guide Both lines should be insulated No line accessories or oil traps should be fitted In cooling

More information

RESERVDELAR/ SPARE PARTS

RESERVDELAR/ SPARE PARTS RESERVDELAR/ SPARE PARTS Washer disinfector 46-2,46-4,46-5 Mfg. no. SEV0440130-5018617-00 Reservdelslista/Spare parts catalogue Reservdelslista/Spare parts catalogue Contents Circulation system 1 5 Circulation

More information

SUPPLY VOLTAGE AIR HANDLING UNIT X101 X102 WB1 DWG. NO. 342289 EB1 DWG. NO. 342280 M1 DWG. NO. 342279 HR-R DWG. NO. 342279. Drawing no.

SUPPLY VOLTAGE AIR HANDLING UNIT X101 X102 WB1 DWG. NO. 342289 EB1 DWG. NO. 342280 M1 DWG. NO. 342279 HR-R DWG. NO. 342279. Drawing no. A SUPPLY VOLTAGE AIR HANDLING UNIT X0 X0 WB EB 0 X A F A & A M HR-R M Symb. Changes Date/Sign.... Unit Date Checked Pos. Name, type, dim. Drawn Projection Appr. Drawing no. Standard Scale Art. Replaces:

More information

SERVICE MANUAL 12VDC WALL THERMOSTAT AIR CONDITIONING SYSTEMS ROOFTOP UNITS ONLY

SERVICE MANUAL 12VDC WALL THERMOSTAT AIR CONDITIONING SYSTEMS ROOFTOP UNITS ONLY SERVICE MANUAL 12VDC WALL THERMOSTAT AIR CONDITIONING SYSTEMS ROOFTOP UNITS ONLY! WARNING - SHOCK HAZARD! TO PREVENT THE POSSIBILITY OF SEVERE PERSONAL INJURY, DEATH, OR EQUIPMENT DAMAGE DUE TO ELECTRICAL

More information

BACK PRESSURE MONITOR Operator Display with Exhaust Temperature KIT 194-722

BACK PRESSURE MONITOR Operator Display with Exhaust Temperature KIT 194-722 HEWITT INDUSTRIES 5492 BOLSA AVE. HUNTINGTON BEACH, CA 92649 PH. (714) 891-9300 FAX. (714) 897-7632 WEBSITE: www.hewittindustries.com E-MAIL: sales@hewittindustries.com BACK PRESSURE MONITOR Operator Display

More information

External temperature sensors for FSC Ultrasonic Flow Meter (thermal flow measurement function)

External temperature sensors for FSC Ultrasonic Flow Meter (thermal flow measurement function) Application: Heat quantity measurement This function calculates the heat quantity received and sent with liquid (water) in cooling and heating. Two 4-20mA inputs are available for temperature measurements.

More information

R22. K Control. Indoor Unit. Nomenclature. Compatibility PL H 3 G K H B. Unit style Heat Pump Horse Power

R22. K Control. Indoor Unit. Nomenclature. Compatibility PL H 3 G K H B. Unit style Heat Pump Horse Power R22. K Control. Indoor Unit. Nomenclature. PL H 3 G K H B Compatibility Unit style Heat Pump Horse Power Control Boost Heaters R22. K Control. Outdoor Unit. Nomenclature. PU H 3 Y K A Compatibility Outdoor

More information

Web Page Manual. GOLD RX, PX, CX, SD, Program Version 1.20

Web Page Manual. GOLD RX, PX, CX, SD, Program Version 1.20 GB.webbE.0 Web Page Manual GOLD RX, PX, CX, SD, Program Version.0. General The air handling unit has a built-in web server that enables you to monitor, enter and change the settings in the air handling

More information

Installation Questions

Installation Questions Installation Questions How do I determine what type of heat I have? There may be several ways to determine what type of heat you have. First, if you can access the unit that is responsible for creating

More information

Aerona Air Source Heat Pumps

Aerona Air Source Heat Pumps ADDENDUM to INSTALLATION INSTRUCTIONS for Aerona Air Source Heat Pumps DOC.87-05/05 Rev.04 March 2013 ATTENTION INSTALLERS - UPDATED INFORMATION! Your Grant Aerona Air Source Heat Pump has a number of

More information

10.1 Indoor Unit Error Display

10.1 Indoor Unit Error Display 10.1 Indoor Unit Error Display Display E0 E1 E2 E3 E5 E6 P0 P1 P2 P4 LED STATUS EEPROM parameter error Indoor / outdoor units communication protection Zero-crossing signal error Fan speed out of control

More information

Thermo Top - Troubleshooting Tree

Thermo Top - Troubleshooting Tree Thermo Top - Troubleshooting Tree 07-15-2002 CAUTION Troubleshooting requires comprehensive knowledge about the structure and theory of operation of the Thermo Top heater. Troubleshooting and repairs may

More information

Indoor coil is too warm in cooling mode or too cold in heating mode. Reversing valve or coil thermistor is faulty

Indoor coil is too warm in cooling mode or too cold in heating mode. Reversing valve or coil thermistor is faulty Codes Room Air Conditioner range: Indoor unit alarm s If timer lamp flashes for 1 second on, 1 second off, this indicates pre heating on the coil during heating mode and is not an error. If timer lamp

More information

Failure code manual. content

Failure code manual. content Failure code manual content 一 wall split AC series 2 二 floor standing AC series. 4 三 portable AC series.. 5 四 dehumidifer 6 五 DC inverter single split series...7 六 DC inverter multi-split series 10 1 一

More information

01-3 0000-00 6810-20 AIR CONDITIONING SYSTEM 1. FFH SPECIFICATION AIR CONDITIONING SYSTEM RODIUS 2004.09

01-3 0000-00 6810-20 AIR CONDITIONING SYSTEM 1. FFH SPECIFICATION AIR CONDITIONING SYSTEM RODIUS 2004.09 0000-00 01-3 6810-20 1. FFH SPECIFICATION 01-4 0000-00 2. SYSTEM LAYOUT AND COMPONENTS 0000-00 01-5 01-6 0000-00 3. FFH GENERAL INFORMATION The system is to increase the coolant temperature quickly by

More information

SERVICE MANUAL REFRIGERATION

SERVICE MANUAL REFRIGERATION SERVICE MANUAL REFRIGERATION ELECTROLUX HOME PRODUCTS S.p.A. Publication no. Spares Operations Italy 599 36 16-90 Corso Lino Zanussi, 30 031117 I - 33080 PORCIA / PN (ITALY) ITZ/SERVICE/AA Fax +39 0434

More information

HVAC Processes. Lecture 7

HVAC Processes. Lecture 7 HVAC Processes Lecture 7 Targets of Lecture General understanding about HVAC systems: Typical HVAC processes Air handling units, fan coil units, exhaust fans Typical plumbing systems Transfer pumps, sump

More information

TEST LEADS KTL04. For use with following model. For use with following model

TEST LEADS KTL04. For use with following model. For use with following model TEST LEADS 7066 7060 1106 1108 1110 1008 2017 2027 2037 2608A 2007A 2006 2412 2004 2040 2046R 2055 2056R 1,200mm Temperature Probe 1106 1108 1110 2608A 1,100mm 7085 KTL04 1109 1009 1011 1012 1,100mm 950mm

More information

REMOTE CONTROL MANUAL

REMOTE CONTROL MANUAL REMOTE CONTROL MANUAL ENGLISH CONTENT PRECAUTIONS...1-2 USING THE REMOTE CONTROL UNIT...3 OPERATION...4-9 Thank you for purchasing our Room Air Conditioner. Before using your air-conditioner, please read

More information

KU DESIGN GUIDELINES APPENDIX XVI RECOMMENDED BAS I/O CONTROL POINTS BY EQUIPMENT / SYSTEM

KU DESIGN GUIDELINES APPENDIX XVI RECOMMENDED BAS I/O CONTROL POINTS BY EQUIPMENT / SYSTEM KU DESIGN GUIDELINES APPENDIX XVI RECOMMENDED BAS I/O CONTROL POINTS BY EQUIPMENT / SYSTEM AIR HANDLING UNITS... 1 CHILLERS... 2 COOLING TOWERS... 2 CLOSED LOOP COOLERS... 2 MISCELLANEOUS SUPPLY FANS...

More information

SERVICE MANUAL. Room Air Conditioner Multi Split type Outdoor unit /R410A DC Inverter/

SERVICE MANUAL. Room Air Conditioner Multi Split type Outdoor unit /R410A DC Inverter/ SERVICE MANUAL Room Air Conditioner Multi Split type Outdoor unit /R410A DC Inverter/ FS2MI-147HFD FS2MI-187HFD FS3MI-217HFD FS3MI-277HFD FS4MI-277HFD FS4MI-367HFD FS5MI-367HFD NOTE: Before servicing the

More information

Portable Air Conditioner

Portable Air Conditioner Portable Air Conditioner Owner's Manual Model:3 in 1 12,000 Btu/h Series 3 Please read this owner s manual carefully before operation and retain it for future reference. CONTENTS 1. SUMMARY...1 2. PORTABLE

More information

1978-83 Malibu 1978-87 Monte Carlo 1978-87 El Camino

1978-83 Malibu 1978-87 Monte Carlo 1978-87 El Camino Important facts about this kit. 1. The dash panel used in this picture is used by permission of Covan's Classic. 2. This kit requires some modification to your original under dash wiring harness. It is

More information

Topvex SX/C, Topvex TX/C. Air Handling Unit

Topvex SX/C, Topvex TX/C. Air Handling Unit Air Handling Unit Document in original language 131677-EN_GB 23-12-2015 A001 Contents 1 Declaration of Conformity... 1 2 Warnings... 2 3 Product information... 2 3.1 General... 2 3.2 Technical data...

More information

543-0032-00, 943-0032-00. User s Manual

543-0032-00, 943-0032-00. User s Manual 543-0032-00, 943-0032-00 User s Manual 1 Comfort Alert Diagnostics Faster Service And Improved Accuracy The Comfort Alert diagnostics module is a breakthrough innovation for troubleshooting heat pump and

More information

sip Sanyo Modbus Guide Technical Specification Pinouts, Cable Connections & Wiring Issue 2: February 2009 Synapsys Solutions Ltd, all rights reserved

sip Sanyo Modbus Guide Technical Specification Pinouts, Cable Connections & Wiring Issue 2: February 2009 Synapsys Solutions Ltd, all rights reserved Sanyo Section : Section : Section : Section : Section : sip Modbus Guide Configuration Modbus Table Technical Specification Pinouts, Cable Connections & Wiring Alarm Fault Codes Issue : February 009 Section

More information

Automatic air conditioning system

Automatic air conditioning system Automatic air conditioning system Air outlets and fan speed are automatically adjusted according to the temperature setting. With navigation system Owners of models equipped with a navigation system should

More information

Despiece MUCR-H3M MUCR-09-H3M CL20834. Multi H3

Despiece MUCR-H3M MUCR-09-H3M CL20834. Multi H3 Despiece MUCR-H3M MUCR-09-H3M CL20834 1 Despiece MUCR-H3M MUCR-09-H3M CL20834 Nº Descripción Ud. Ref. Proveedor Código 1 Air outlet frame assy 1 01865216 2 Cover of Air Outlet 1 01265298 3 Water Tray Assy

More information

SERVICE MANUAL FOR 12 VDC WALL THERMOSTAT AIR CONDITIONING SYSTEMS ROOF TOP UNITS ONLY

SERVICE MANUAL FOR 12 VDC WALL THERMOSTAT AIR CONDITIONING SYSTEMS ROOF TOP UNITS ONLY RV Products Division SERVICE MANUAL FOR 12 VDC WALL THERMOSTAT AIR CONDITIONING SYSTEMS ROOF TOP UNITS ONLY Airxcel, Inc. RV Products Division P.O. Box 4020 Wichita, KS 67204 1976A376 (1-11) TABLE OF CONTENTS

More information

GREEN DATA CENTER DESIGN

GREEN DATA CENTER DESIGN Jeffrey Menig Global Facilities Facility Engineering The application of multiple available technologies resulting in improved energy optimization without significantly increasing capital investment. A

More information

SHOWER WATER HEATER MODEL BS 35 / 45 / 60 BS 35 E / 45 E / 60 E OPERATION AND INSTALLATION INSTRUCTIONS

SHOWER WATER HEATER MODEL BS 35 / 45 / 60 BS 35 E / 45 E / 60 E OPERATION AND INSTALLATION INSTRUCTIONS SHOWER WATER HEATER MODEL BS 35 / 45 / 60 BS 35 E / 45 E / 60 E OPERATION AND INSTALLATION INSTRUCTIONS 2 This water heater must be installed (water and electrical installation), commissioned and serviced

More information

LG Air Conditioning Multi F(DX) Fault Codes Sheet. Multi Split Units

LG Air Conditioning Multi F(DX) Fault Codes Sheet. Multi Split Units Multi Split Units If there is a fault on any LG Multi unit, an Error mark is indicated on the display window of the indoor unit, wired-remote controller, and LED s of outdoor unit control board. A two

More information

4 Alarm and info. Alarm. Yes Warning. No Information No Reset alarms > No Current list > Alarm log list > Delete alarm log > No

4 Alarm and info. Alarm. Yes Warning. No Information No Reset alarms > No Current list > Alarm log list > Delete alarm log > No 6. 6.1 and info (Menu 4) NB are shown in the event of unit faults or irregular operation Check the Current list (Menu 4) for alarm messages and refer to the list of alarms given at the end of these instructions.

More information

SERVICE INSTRUCTION R410A. SPLIT TYPE ROOM AIR CONDITIONER Universal Floor / Ceiling Duct / Cassette Wall Mounted / Floor type INVERTER MULTI

SERVICE INSTRUCTION R410A. SPLIT TYPE ROOM AIR CONDITIONER Universal Floor / Ceiling Duct / Cassette Wall Mounted / Floor type INVERTER MULTI SERVICE INSTRUCTION SPLIT TYPE ROOM AIR CONDITIONER Universal Floor / Ceiling Duct / Cassette Wall Mounted / Floor type INVERTER MULTI R410A Models Indoor unit Outdoor unit AB*14LBAJ AB*18LBAJ AB*F14LAT

More information

COMMISSIONING OF HVAC SYSTEMS

COMMISSIONING OF HVAC SYSTEMS FORM CL-01 SYSTEMS / EQUIPMENT INCLUDED : SYSTEM STARTUP CHECKLIST I - PRE - STARTUP INSPECTION EQUIPMENT MOUNTING & SETTING CONTROL, INTERLOCK & POWER WIRING ALIGNMENT OF MOTORS & DRIVES PIPING, CONNECTIONS

More information

MP-4000 Alarm List (Software version 2.4.3 or later)

MP-4000 Alarm List (Software version 2.4.3 or later) Service Bulletin SUBJECT: MP4000 Alarm s BULLETIN: C 100 DATE: June 19, 2013 ALARM LIST Where it is possible the alarm number is kept the same as for MP-3000. MP-3000 holds alarm number from 0 to 127.

More information

Max primary circuit temperature 90ºC Max primary circuit temp. 90ºC Max secondary circuit temperature 45ºC Max secondary circuit temp.

Max primary circuit temperature 90ºC Max primary circuit temp. 90ºC Max secondary circuit temperature 45ºC Max secondary circuit temp. EGLISH 1 Product description exchanger equipped with an electronic control unit and circulation pump for the primary circuit. All Aqua-Mex variants can be ordered with an interior coil of either titanium

More information

Service manual. Website: www.andico.com.au CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL.

Service manual. Website: www.andico.com.au CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL. Website: www.andico.com.au Service manual CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL. - ONLY FOR AUTHORISED SERVICE PERSONNEL. MODELS: MPK1-09CR-QB8 MPK1-12ER-QB6

More information

What s the Difference? 2 Pipe vs 4 Pipe Fan Coil

What s the Difference? 2 Pipe vs 4 Pipe Fan Coil Head Office Neptronic 400 Lebeau Blvd. Montreal, Quebec, Canada H4N R6 Tel.: (54) -4 Fax: (54) -6 Toll Free: -800-6-08 What s the Difference? Pipe vs 4 Pipe Coil There are many questions that arise when

More information

AIR COOLED CHILLER CHILLED WATER PUMP CONTROL: The chilled water pump with the lowest runtime will automatically start when the outside air temperature rises above the system enable setpoint. When the

More information

1 4. 3 4-2 ABNORMAL OPERATION. 4-2-1 Error code Display. Specifics Error Code. Subsection Error Code. Subsection and Specifics Error code target

1 4. 3 4-2 ABNORMAL OPERATION. 4-2-1 Error code Display. Specifics Error Code. Subsection Error Code. Subsection and Specifics Error code target 4-2 ABNORMAL OPERATI 4-2-1 An is represented by 3 digit characters. The first 2 digit means the subsection, and the last 1 digit means the specifics. Ex.) Indoor unit Network communication Error Subsection

More information

Cylinder head gasket, replacement

Cylinder head gasket, replacement "VCC065612 EN 20110604" 1(7) Cylinder head gasket, replacement Special tools: 999 5098 Disconnect battery earth lead Drain coolant Remove heat shield over exhaust manifold. (Only the two bottom bolts on

More information

Si10-417_C. Pocket Manual. Service Diagnosis SPLIT & MULTI

Si10-417_C. Pocket Manual. Service Diagnosis SPLIT & MULTI Pocket Manual Service Diagnosis SPLIT & MULTI Service Diagnosis SPLIT & MULTI 1. Troubleshooting with LED...5 1.1 Indoor Unit... 5 1.2 Outdoor Unit... 10 2. Troubleshooting by Symptoms...11 2.1 Air conditioner

More information

Tour of new eircom Data Centre Blanchardstown by Dervan Engineering Consultants 11 th March 2015

Tour of new eircom Data Centre Blanchardstown by Dervan Engineering Consultants 11 th March 2015 Tour of new eircom Data Centre Blanchardstown by Dervan Engineering Consultants 11 th March 2015 Presentation Outline Mechanical Overview Chillers and Pumps Pipework and Ancillaries In Row Cooling Units

More information

LG Air Conditioning - Universal Split Fault Codes Sheet. Universal Split Systems

LG Air Conditioning - Universal Split Fault Codes Sheet. Universal Split Systems Universal Split Systems If there is a fault on any LG Universal unit, a two digit number will appear on the remote controllers led display. If the unit does not have a remote controller the fault will

More information

User's Guide. CTS6000 WebControl

User's Guide. CTS6000 WebControl User's Guide CTS6000 WebControl Version 1.01, 29.06.2010 Contents Contents... 2 List of figures... 3 Introduction... 4 Introduction to CTS6000... 4 Reading instructions... 4 Quick startup... 5 Daily operation...

More information

Split Controller. User Manual SM-SS-F 2009/01/04

Split Controller. User Manual SM-SS-F 2009/01/04 Split Controller SM-SS-F User Manual 2009/01/04 Table of contents 1. Parts illustration.... 1 2. Electrical technical data...... 2 3. Electrical connection...3 4. Assemble parts...4 4.1 Assemble the fixed

More information

OVEN PARTS For Models:GMC305PDB07, GMC305PDQ07, GMC305PDT07, GMC305PDS07 (Black) (White) (Biscuit) (S.Steel)

OVEN PARTS For Models:GMC305PDB07, GMC305PDQ07, GMC305PDT07, GMC305PDS07 (Black) (White) (Biscuit) (S.Steel) OVEN PARTS 30" BUILT IN ELECTRIC COMBO SENSOR/SC (GOLD LINE) 7 03 Litho In U.S.A. (cre) 1 Part No. OVEN PARTS NOTE: The screws and nuts required to attach a part are listed immediately following that part.

More information

E2 Series Electric Furnaces

E2 Series Electric Furnaces E2 Series Electric Furnaces Service Manual Table of Contents Electrical Requirements... 10 Codes, Specifications Requirements... 10 Connection Supply Service Wires... 10 Furnace Sequence of Operation...

More information

PNEUMATIC CONTROLS Selection and Description

PNEUMATIC CONTROLS Selection and Description PNEUMATIC CONTROLS Selection and Description Carnes pneumatic controlled throttling units are suitable for a standard 20 psi control system and may be supplied with pressure dependent or pressure independent

More information

Simple Electronic Transmission

Simple Electronic Transmission Simple Electronic Transmission Matthew Whitten Brookhaven College Created with materials from Tom Birch 1 Basically a Hydraulic System An electronic transmission is a hydraulically-operated unit that has

More information

FZ400 1997-1998 WIRING DIAGRAM (JAPANESE MARKET FAZER 400) 5

FZ400 1997-1998 WIRING DIAGRAM (JAPANESE MARKET FAZER 400) 5 FZ400 1997-1998 WIRING DIAGRAM (JAPANESE MARKET FAZER 400) 5 1 2 4 7 6 11 12 13 13 12 13 3 13 8 9 56 14 59 52 54 15 48 55 34 22 16 51 50 60 47 46 36 35 23 17 49 24 25 18 44 37 38 39 40 58 33 26 27 28 29

More information

CONTENTS 1. IMPORTANT NOTICE 2 2. TECHNICAL SPECIFICATION 3 3. OPERATION DETAILS 4 4. WIRING DIAGRAM 11 5. EXPLOSION VIEW 12 6.

CONTENTS 1. IMPORTANT NOTICE 2 2. TECHNICAL SPECIFICATION 3 3. OPERATION DETAILS 4 4. WIRING DIAGRAM 11 5. EXPLOSION VIEW 12 6. TCL WALL MOUNTED SPLIT-TYPE AIR CONDITIONERS SERVICE MANUAL No.TE051220 Models TAC-09CHSA/GI TAC-12CHSA/GI CONTENTS 1. IMPORTANT NOTICE 2 2. TECHNICAL SPECIFICATION 3 3. OPERATION DETAILS 4 4. WIRING DIAGRAM

More information

EKON BMS HVAC system. Simply Smart. www.ekonhome.com. Touch Screen Controller. Going green. Wireless. Wireless Thermostat with Light Switch

EKON BMS HVAC system. Simply Smart. www.ekonhome.com. Touch Screen Controller. Going green. Wireless. Wireless Thermostat with Light Switch Going green EKON BMS HVAC system Wireless Thermostat with Light Switch Control Fan Coil or Central AirCon Wireless Touch Screen Controller Wireless Light or Motorized Blind Wall Switch www.ekonhome.com

More information

Transporter Current Flow Diagram No. 80 / 1

Transporter Current Flow Diagram No. 80 / 1 Transporter Current Flow Diagram No. 80 / 1 2.5 l/65 kw direct injection turbo diesel, engine code AJT From May 1999 2.5 l/75 kw direct injection turbo diesel, engine codes ACV, AUF 2.5 l/111 kw direct

More information

3-2. Using the air conditioning system and defogger Automatic air conditioning system

3-2. Using the air conditioning system and defogger Automatic air conditioning system Automatic air conditioning system Airflow and outlets are automatically adjusted according to the temperature setting. Press to display the air conditioning operation screen. Air conditioning operation

More information

spare parts Spare parts for 10 ton C-clamps Straightening > C-clamps > 10 ton

spare parts Spare parts for 10 ton C-clamps Straightening > C-clamps > 10 ton Straightening > C-clamps > 10 ton Spare parts for 10 ton C-clamps I-17475 10890 Repair kit for 10 ton NIKE CF110-310 I-AQU8 10945 Snap-on coupling male I-CF110C 10951 10 ton press cylinder 150 mm stroke

More information

PRE-LEASE SURVEY OF THE ENGINEERING SERVICES. XXXX London

PRE-LEASE SURVEY OF THE ENGINEERING SERVICES. XXXX London PRE-LEASE SURVEY OF THE ENGINEERING SERVICES AT London Client: Clients Representative: For the Attention of: Telephone N o Site Address: London Report prepared by: Contact Name: FHP Engineering Services

More information

K-Type Thermocouple Sensor User s Guide

K-Type Thermocouple Sensor User s Guide K-Type Thermocouple Sensor User s Guide 1 TABLE OF CONTENTS: 1 INTRODUCTION... 2 2 TYPICAL APPLICATION:... 2 3 INSTALLATION RULES:... 2 3.1 Connecting the sensor to M1/MD4 data logger:... 2 3.2 Connecting

More information

A/C-HEATER SYSTEM - AUTOMATIC

A/C-HEATER SYSTEM - AUTOMATIC A/C-HEATER SYSTEM - AUTOMATIC 1995 Volvo 850 1995-96 Auto. A/C-Heater Systems Volvo 850 * PLEASE READ THIS FIRST * WARNING: To avoid injury from accidental air bag deployment, read and carefully follow

More information

Service manual. The voltage in P3 and P4 in outdoor PCB is high voltage about 310V The voltage in P5 and P6 in outdoor PCB is high voltage about 310V

Service manual. The voltage in P3 and P4 in outdoor PCB is high voltage about 310V The voltage in P5 and P6 in outdoor PCB is high voltage about 310V Resistance The voltage in P3 and P4 in outdoor PCB is high voltage about 310V The voltage in P5 and P6 in outdoor PCB is high voltage about 310V 9.2 Troubleshooting for indoor unit E0 E1 E2 E3 E5 E6 P0

More information

Configuring Alarms & Relays in the Enhanced Transformer Advantage

Configuring Alarms & Relays in the Enhanced Transformer Advantage Configuring s & Relays in the Enhanced Transformer Advantage The Transformer Advantage product family offers a variety of relay options. Some choices are made when the Advantage is specified and ordered.

More information

Overheating limit control

Overheating limit control Pahlén electric heater Maxi Heat with digital control is a compact and effective heater for swimming pools. It consists of a glassfibre reinforced polypropylene tank containing resistance-type heating

More information

Characterised control valve (CCV) with adjustable flow rate and sensoroperated flow control, and power and energy-monitoring function

Characterised control valve (CCV) with adjustable flow rate and sensoroperated flow control, and power and energy-monitoring function Belimo Energy Valve TM web server manual P6..W..EV-BAC Characterised control valve (CCV) with adjustable flow rate and sensoroperated flow control, and power and energy-monitoring function Contents General

More information

Transport Air Conditioning TRANSPORT AIR CONDITIONING OPERATOR S MANUAL. for SPLIT SYSTEM. Bus Air Conditioning Units.

Transport Air Conditioning TRANSPORT AIR CONDITIONING OPERATOR S MANUAL. for SPLIT SYSTEM. Bus Air Conditioning Units. R Transport Air Conditioning TRANSPORT AIR CONDITIONING OPERATOR S MANUAL for SPLIT SYSTEM Bus Air Conditioning Units T--326 Rev -- OPERATOR S MANUAL BUS AIR CONDITIONING UNITS GEN IV & GEN V CONTENTS

More information

ELECTRIC CENTRAL HEATING FLOW BOILER

ELECTRIC CENTRAL HEATING FLOW BOILER ELECTRIC CENTRAL HEATING FLOW BOILER EKCO.T Used product can t be treated as general communal waste. Disassembled appliance has to be delivered to the collection point of electrical and electronic equipment

More information

case studies Safely applied, Environmentally creative and effective engineering solutions

case studies Safely applied, Environmentally creative and effective engineering solutions Safely applied, Environmentally creative and effective engineering solutions T: 02392 435050 @: eng@itdconsultants.co.uk www.itdconsultants.co.uk case studies Churchill House Main Features: A 1.5m refurbishment

More information

Workshop 7 PC Software - Tracker

Workshop 7 PC Software - Tracker Workshop 7 PC Software - Tracker Goal: You will startup and perform advanced setup functions using Tracker PC software. You will also setup equations to control MP503 binary outputs. The Binary Output

More information

ALL IN ONE. Heat Pump Water Heater

ALL IN ONE. Heat Pump Water Heater ALL IN ONE Heat Pump Water Heater INSTALLATION AND OPERATION INSTRUCTIONS Please read this user s manual carefully before operate the unit. www.airtradecentre.com CONTENTS A. IMPORTANT REMARKS ------------------------------------------------------------------------------------------------

More information

Models: Contents. Cabinet Components. Functional Components " Exploded View... 3 " Usage List... 4. Control Panel. Blower Housing

Models: Contents. Cabinet Components. Functional Components  Exploded View... 3  Usage List... 4. Control Panel. Blower Housing REPLACEMENT PARTS MANUAL WALL MOUNTED PACKAGE HEAT PUMPS Models: WH301 WH361 General Notes! Revised and/or additional pages may be issued from time to time.! A complete and current manual consists of pages

More information

OVEN PARTS For Models:GSC308PJB05, GSC308PJQ05, GSC308PJT05, GSC308PJS05 (Black) (White) (Biscuit) (Black Stainless)

OVEN PARTS For Models:GSC308PJB05, GSC308PJQ05, GSC308PJT05, GSC308PJS05 (Black) (White) (Biscuit) (Black Stainless) OVEN PARTS 30" BUILT IN ELECTRIC COMBO SENSOR/SC (GOLD LINE) 3 05 Litho In U.S.A. (cre) 1 Part No. Rev.A OVEN PARTS 1 Literature Parts 4455994 Installation Instructions Use & Care Guide 8300346 Microwave

More information

Electrical Systems - IQAN Digital Control System. IQAN Control System Components... 5.1.3

Electrical Systems - IQAN Digital Control System. IQAN Control System Components... 5.1.3 Section 5.1 Electrical Systems - IQAN Digital Control System IQAN Control System Components........................... 5.1.3 IQAN Operational Description: At Machine Startup.....................................

More information

S & P COIL PRODUCTS LTD SPC HOUSE, EVINGTON VALLEY ROAD, LEICESTER. LE5 5LU. Electrical layouts for EC Motors in Fan Convector units

S & P COIL PRODUCTS LTD SPC HOUSE, EVINGTON VALLEY ROAD, LEICESTER. LE5 5LU. Electrical layouts for EC Motors in Fan Convector units S & P COI PRODUCTS TD SPC HOUSE, EVIGTO VAEY ROAD, EICESTER. E5 5U Guidance Document Electrical layouts for EC Motors in Fan Convector units Hasnain Merchant Richard Meskimmon 4/9/0 This document is intended

More information

REMOVAL AND INSTALLATION

REMOVAL AND INSTALLATION 303-01C-1 REMOVAL AND INSTALLATION Engine Body On Special Tool(s) Adapter For 303-D043 303-D043-02 or equivalent Special Tool(s) 303-01C-1 Turbocharger Lifting Bracket 303-1266 Wrench, Fan Clutch Nut 303-214

More information

CEILING CASSETTE FAN COIL UNIT

CEILING CASSETTE FAN COIL UNIT CEILING CASSETTE FAN COIL UNIT Operation and Installation Manual MHCFC4W-04, 08, 12, 16 Four way ceiling cassette fan coil unit Please read this manual before using the fan coil unit. Installation and

More information

Installation and maintenance instructions. Danfoss Vent

Installation and maintenance instructions. Danfoss Vent Installation and maintenance instructions Danfoss Vent 1 Unit design... 2 2 Project planning and installation instructions... 3 2.1 Ventilation...3 2.2 Piping installation....3 2.3 Condensation line...4

More information

INSTALLATION MANUAL INSIDE ENGINE COMPARTMENT ZZT22#R (1ZZ-FE / 3ZZ-FE) / AZT220R (1AZ-FE) FOR EUROPEAN SPEC. AIR CONDITIONING ENGLISH.

INSTALLATION MANUAL INSIDE ENGINE COMPARTMENT ZZT22#R (1ZZ-FE / 3ZZ-FE) / AZT220R (1AZ-FE) FOR EUROPEAN SPEC. AIR CONDITIONING ENGLISH. HFC 134a Ozone Friendly Refrigerant ZZT22#R (1ZZ-FE / 3ZZ-FE) / AZT220R (1AZ-FE) FOR EUROPEAN SPEC. AIR CONDITIONING ENGLISH AAAMU-63 INSIDE ENGINE COMPARTMENT INSTALLATION MANUAL 2000 (EUROPE) B.V.. All

More information

Troubleshooting Guide for Jacks Down LED Lights

Troubleshooting Guide for Jacks Down LED Lights Troubleshooting Guide for Jacks Down LED Lights Equalizer Systems Auto-Level systems manufactured after 2005 feature a pressure switch system that monitors the retracted state of leveling jacks and any

More information

Impact of Control System Technologies on Industrial Energy Savings

Impact of Control System Technologies on Industrial Energy Savings Impact of Control System Technologies on Industrial Energy Savings Priyam Parikh Industrial Assessment Center Texas A&M University Bryan P. Rasmussen Industrial Assessment Center Texas A&M University http://farolconsulting.com/?page_id=110

More information

Web Page Manual. GOLD RX, PX, CX, SD Program Version 5.00 or better GOLD LP/COMPACT Program Version 2.00 or better

Web Page Manual. GOLD RX, PX, CX, SD Program Version 5.00 or better GOLD LP/COMPACT Program Version 2.00 or better Web Page Manual GOLD RX, PX, CX, SD Program Version 5.00 or better GOLD LP/COMPACT Program Version 2.00 or better 1. GENERAL The air handling unit has a built-in web server that enables you to monitor,

More information

Contents. Introduction

Contents. Introduction TION Contents Introduction...1 Basics...2 Main Menu Structure...3 Time Schedule Menu...4 Settings Menu...5 Reports Menu...6 Date / Time Adjustment Menu...7 Introduction TION is an advanced control device

More information

PLEASE READ ALL DIRECTIONS BEFORE STARTING INSTALLATION

PLEASE READ ALL DIRECTIONS BEFORE STARTING INSTALLATION PARTS LIST FUEL AND IGNITION 2012-2014 Yamaha T-Max 530 Installation Instructions 1 Power Commander 1 USB Cable 1 Installation Guide 2 Power Commander Decals 2 Dynojet Decals 2 Velcro strips 1 Alcohol

More information

Technical service manual 2009

Technical service manual 2009 MULTI SPLIT TYPE, HEAT PUMP AIR CONDITIONERS Technical service manual 2009 KSIM MULTI ZONE SERIES R410A DC Inverter multi Series Models KSIM20912-H216 KSIM30912-H216 KSIM40912-H216 CONTENT 1. Product features

More information

Sensi TM. Wi-Fi Programmable Thermostat MANUAL OPERATION. Version: March 2016 2016 Emerson Electric Co. All rights reserved.

Sensi TM. Wi-Fi Programmable Thermostat MANUAL OPERATION. Version: March 2016 2016 Emerson Electric Co. All rights reserved. Sensi TM Wi-Fi Programmable Thermostat MANUAL OPERATION Version: March 2016 2016 Emerson Electric Co. All rights reserved. Contents MANUAL OPERATION GUIDE Buttons and Icons 3 Basic Functionality 4 Manual

More information

Heating, Ventilation and Air Conditioning

Heating, Ventilation and Air Conditioning Heating, Ventilation and Air Conditioning Y = 100.0 % 100 % 22.0 C Overriding Sensor Values 1800 mbar 2000 mbar Y = 100.0 79.4 % 12.0 C 31.0 C 15.0 C 27.1 C 47 % 0 % Fault Collective malfunction: Pre-flush:

More information

SIT Sports. Safety Tracking System Manual WRC 2015

SIT Sports. Safety Tracking System Manual WRC 2015 SIT Sports Safety Tracking System WRC 2015 V2 1 SIT Sports Tracking Unit The SIT Sports Tracking unit must be fitted and connected in all competitors cars before arrival at scrutineering, where it will

More information

13. Troubleshooting. Indoor unit s LED indication of Corona DC inverter unit. Indoor unit s LED indication of Alfa DC inverter unit

13. Troubleshooting. Indoor unit s LED indication of Corona DC inverter unit. Indoor unit s LED indication of Alfa DC inverter unit Troubleshooting 13. Troubleshooting Indoor unit s LED indication of Corona DC inverter unit MCAC-HTSM-2007-11 E0 E1 E2 E3 E5 E6 P0 P1 P2 P3 P5 EEPROM error outdoor communication error Zero-crossing examination

More information

Emission Control Systems Warranties

Emission Control Systems Warranties 2004 Chevrolet TrailBlazer - 2WD Emission Control Systems Warranties This section outlines the emission warranties that General Motors provides for your vehicle in accordance with the U.S. Federal Clean

More information

Zehnder Focus 200. Ventilation device

Zehnder Focus 200. Ventilation device Ventilation device Use The Zehnder Focus (F) 200 comfort ventilation unit was specially developed for use in demanding residential and commercial buildings. It combines maximum comfort, simple operation

More information

INSTALLATION AND OPERATION MANUAL

INSTALLATION AND OPERATION MANUAL RCS MODEL ZC4 4 ZONE HVAC INSTALLATION AND OPERATION MANUAL DCN: 141-0020-02 /0/03 INTRODUCTION The 4 Zone HVAC Controller series allows up to 4 standard electronic thermostats to independently control

More information

TECHNICAL SERVICE DEPARTMENT Technical Service Bulletin 1-800-432-8373. 2 Inch PowerVent LED Indicator Explanations & Troubleshooting Table

TECHNICAL SERVICE DEPARTMENT Technical Service Bulletin 1-800-432-8373. 2 Inch PowerVent LED Indicator Explanations & Troubleshooting Table New Robertshaw control valve was introduced in May 2008 as a replacement part. See last page for troubleshooting this replacement part. All voltage inputs are 120V. All electrical connectors are Molex

More information

ENHANCED LABORATORY HVAC SYSTEM

ENHANCED LABORATORY HVAC SYSTEM ENHANCED LABORATORY HVAC SYSTEM INTRODUCTION Since the early 1980's the attention to more energy efficient laboratory designs has been on the rise due to the increase in energy cost and the emergence of

More information

Heat Surge Model X5C Fire Place Insert Service Manual Applies to all units w/30000208 circuit board

Heat Surge Model X5C Fire Place Insert Service Manual Applies to all units w/30000208 circuit board Heat Surge Model X5C Fire Place Insert Service Manual Applies to all units w/30000208 circuit board 2012 HS M4417A BR16597R-1 HEAT SURGE 8000 FREEDOM AVE, N. CANTON, OH 44720 330-244-8161 WWW.HEATSURGE.COM

More information

WALL MOUNTED PACKAGE HEAT PUMPS REPLACEMENT PARTS MANUAL WH483 WH602. Contents. General Notes. Important. Description

WALL MOUNTED PACKAGE HEAT PUMPS REPLACEMENT PARTS MANUAL WH483 WH602. Contents. General Notes. Important. Description REPLACEMENT PARTS MANUAL WALL MOUNTED PACKAGE HEAT PUMPS Models: WH421 WH483 WH602 General Notes Contents Ø Ø Revised and/or additional pages may be issued from time to time. A complete and current manual

More information

squrboxbox heat recovery squrboxbox I technical information

squrboxbox heat recovery squrboxbox I technical information heatrecoveryrange heat recovery squrboxbox I technical information squrboxbox Low depth high performance Only 350mm deep & up to 430l/s, providing the most effective low depth solution. Quietest solution

More information

BABIES SUNNIES TEENIES. 0-4 år / years. 5-8 år / years. 7-12 år / years

BABIES SUNNIES TEENIES. 0-4 år / years. 5-8 år / years. 7-12 år / years 2015-2015 01 12 BABIES 0-4 år / years SUNNIES 5-8 år / years TEENIES 7-12 år / years De färgade linserna har linskategori 3 vilket betyder att de är kraftigt tonade och kan användas vid intensiv solstrålning

More information

Alfa Romeo 147 On board instruments installation guide

Alfa Romeo 147 On board instruments installation guide Alfa Romeo 147 On board instruments installation guide Alfa Romeo 147 On board instruments installation guide This guide is describing how I installed oil temperature and oil pressure gauges to my Alfa

More information