OPP-ROOM active room temperature sensor T- -R-

Size: px
Start display at page:

Download "OPP-ROOM active room temperature sensor T- -R-"

Transcription

1 OPP-ROOM active room temperature sensor T- -R- Technical Data Power supply: V AC/DC -0% / +5%, max. W Signal outputs: T-TV voltage transmitter 3 x 0 0 V DC < 5mA T-TC current transmitter 2 x 4 20 ma max. 250 Ω MOD / BAC digital Sensor specifications: Temperature Range 0 50 C Accuracy ± 0.5 C Ambient conditions: Operating temperature: 0 50 C Operating relative humidity: 0 95% RH (non-condensing) Storage temperature: C Storage relative humidity: 0 95% RH (non-condensing) Option D LCD display to display temperature and alarm status with backlighting (software configurable) Option P Active setpoint adjustment (only BUS transmitters, for setpoint adjustments, adjustable min./max. limits) Option P2 Passive setpoint adjustment (only voltage and current transmitters, 0 kω potentiometer for external devices) 0 0 kω resistor, 0 V Option BL Pushbutton, illuminated; Status available via digital output 2 x V AC Triacs (DO + DO2), max. 2 A, requires V AC power supply (MOD and BAC versions are shipped with digital outputs in standard configuration) New Longline design - design-protected Large LCD display with backlight Display alarm function (yellow + red) for temperature Setpoint potentiometer and illuminable push button as option Analog outputs voltage (0 0 V DC) or current (4 20 ma) Convenient parameter programming with OR-C configuration Software Also available as BACnet / Modbus Protection type: IP 20 Housing: ABS plastic, self-extinguishing, white, similar to RAL 900 Wall installation Dimensions: (L x W x D) ca. 6 x 20 x 25 mm Weight: 0g Cable connection: Screw terminals mm² Function For Measuring interior air temperatures. Installation All work (such as installation, electrical connection, startup, operation, and maintenance) must only be performed by sufficiently qualified tradesmen. The respectively applicable local rules and regulations (e.g. national building codes, electrical/vde regulations, etc.) must be observed. Installers and operating entities are required to sufficiently familiarize themselves before startup. Read the product description before operating the equipment. Verify that the product can be used for the relevant application without restrictions. We are not liable for printing errors and changes after printing. Appropriate use implies compliance with operating and installation instructions. We are not liable for losses due to inappropriate use. Unauthorized or inappropriate manipulations or modifications of the device render the operating permit, the product warranty and warranty claims null and void. Room temperature sensor, active Data sheet No Version

2 Ordering designations Transmitter type without display Electrical connection Current transmitter T-TC-R and voltage transmitter T-TV-R DO + DO2 only with -BL button option, switching output with Triac, V AC power supply needed. power supply V AC/DC 0 common ground connection T-TV-R: Y, Y2, Y3 Analog output 0 0 V DC -R -R-P** -R-P2** basic configuration with setpoint potentiometer -R-BL with button -R-PBL** -R-P2BL** with setpoint potentiometer and button T-TV voltage transmitter T-TC current transmitter T-MOD Modbus transmitter (Modbus RTU) T-BAC BACnet transmitter (MS/TP) Transmitter type with display -R-D basic configuration -R-D-P** -R-D-P2** with setpoint potentiometer -R-D-BL with button -R-D-PBL** -R-D-P2BL** with setpoint potentiometer and button T-TV voltage transmitter T-TC current transmitter T-MOD Modbus transmitter (Modbus RTU) T-BAC BACnet transmitter (MS/TP) T-TC-R: Y and Y2 (no Y3) Analog output 4 20 ma **Options P and P2 cannot be installed at the same time. Y, Y2, Y3 function selectable, temperature measurement is standard 0 common ground connection SPR passive setpoint, 0 0 kω (Option P2) VAC Relay DO Digital output (with -BL) VAC Relay DO2 Digital output 2 (with -BL) VAC/DC 0 V o VAC/DC Supply Y TV: 0 0 V DC; TC: 4 20mA Temperature* Y2 TV: 0 0 V DC; TC: 4 20mA Controller* Y3 TV: 0 0 V DC o 0 V ND * Each of the outputs can be configured individually for temperature measurement or control o 0 V ND SPR Passive target value, 0 0 kω (Option P2) TE not assigned SETPOINT POTENTIOMETER T-TV T-TC Programming connector CAB-02 Modbus transmitter T-MOD-R and BACnet transmitter T-BAC-R DO + DO2 DO + DO2 switching output VAC/DC with Triac, V AC power supply needed 0 V power supply V AC/DC 0 common ground connection Y, Y2, Y3 analog output 0 0 V DC Function selectable, temperature measurement is standard for Y A + RS45, Bus A + Network B RS45, Bus B 0 ground or bus shield RI resistor input 0 50 kω, e.g. NTC0 DI Switching input, potential-free, e.g. for door or window contact VAC Relay VAC Relay Precautionary measures for wiring Switch off the power supply before changing wiring of any kind. If the sensor is equipped with the LCD display, disconnect the LCD display and then connect the power supply and any applicable analog outputs. After connecting the wiring, seat the display into the socket and switch on the sensor. DO DO2 o Y Y2 Y3 o Digital output Digital output 2 VAC/DC Supply Output 0 0 V Temperature* Output 0 0 V* Output 0 0 V* 0 V ND Bus DIP switch * Each of the outputs can be configured individually for temperature measurement or control A + RS45 Bus A + B RS45 Bus B o 0 V ND (Shield) RI DI RI2 DI2 Jumper for bus terminating resistor only with VAC power supply Network Address Bit Rate Bit Rate 2 Resistor input (0 50 kω z. B. NTC0) Switching input (Closing contact, potential-free) not assigned not assigned LED Bus communication Programming connector CAB Room temperature sensor, active Data sheet No Version

3 Accessories: Description Type Windows configuration software. m USB cable OR-C CAB-02 For the following pages please also note the instructions in data sheet no (OR-C configuration software)! Configuration parameters and programming Parameters can be adjusted using the sensor configuration software. The PC with the previously installed OR-C software is connected to the programming head of the sensor with a USB cable, as shown in the figure on the right. The correct procedure for connecting the sensor via USB is as follows: Disconnect the USB connector from the PC Disconnect the sensor from the power supply Insert the 4-way connection into the sensor observe sequence of the cable coloring: Contact no. Color Red 2 White 3 reen 4 Black Connect the USB connector with the PC Reconnect the sensor to the power supply PRO Programming interface Red White reen Black USB PRORAMMIN- CABLE CAB-02 Important instructions: Always disconnect the USB connector from the PC before inserting the cable into the sensor. It is essential that you comply with the correct sequence of the cable coloring. Non-compliance with these instructions may damage the transmitter! Display (Option D required) The LCD display displays the currently measured temperature. If the transmitter is equipped with the setpoint value potentiometer P, the display switches to the setpoint when the control button is rotated. After five seconds, the display automatically returns to the current actual value. The display has white backlighting (default: switched off). The backlighting can be permanently switched on and has adjustable brightness. DISPLAY MODE TEMPERATURE- DISPLAY SETPOINT- DISPLAY Note: The backlighting is permanently on when activated. At an intensity of 50%, the service life is approximately 0,000 hours. Thereafter, the LCD module needs to be replaced if the backlighting is needed. However, the display also works without backlighting. The current target value is displayed when the button is rotated (unit shows influencing parameter). Alarm display with Option D The sensor can be configured so that the temperature is monitored and the LCD display changes the backlighting color as soon as a previously programmed threshold value is exceeded. If the sensor reading exceeds the yellow alarm threshold, the yellow backlighting turns on. If the sensor reading exceeds the red alarm threshold, the backlighting switches to red. Under normal conditions, the backlighting is off (white backlighting can be activated but note the service life of 0,000 hours at 00% brightness). The alarm mode has an adjustable hysteresis to avoid flickering. All alarm thresholds are adjustable. Room temperature sensor, active Data sheet No Version

4 Y/Y2/Y3 analog output mode (Modes) Output mode Temperature measurement (default for Y) Temperature control Specified via bus Description The output signal is proportional to the measured room temperature. The default scale for the temperature range from 0 50 C is 0 0 V (T-TV-R) or 4 20 ma (T-TC-R). The output signal is proportional to the temperature controller setting. The output is programmed via the bus. See parameter Analog output Y... bypass value Note: T-TC-R transmitters only have access to outputs Y and Y2 DO/DO2 output (Option for T-TC-R and T-TV-R, series for T-MOD-R and T-BAC-R) If the pushbutton option(-bl) is installed, DO/DO2 can be set to when the pushbutton is pushed (shut-off lag). DO can also be used to control the temperature. Digital output mode options Temperature control mode (e.g. low temperature limit) Pushbutton (requires -BL option) Specified via bus Description (typical operation) Inverted mode: DO/DO2 switches when the temperature drops below the setpoint minus the hysteresis. The output switches when the temperature exceeds the setpoint. The control direction is adjustable: inverted (heating) /direct (cooling). When the -BL option is installed, it is possible to switch on the DO/DO2 for the Pushbutton lag time (indicated in the settings) after pressing the button. The output is switched on and off via the bus. BACnet MS/TP The OPP-ROOM_BACnet documentation (PICS, EPICS, EDE and BTL certificate) can be found on our home page in the Products Download Technical Information, complete in a zipped folder. 4 7 Room temperature sensor, active Data sheet No Version

5 Programming the Modbus address and the baud rate The Modbus address and the baud rate of the T-MOD-R is generally programmed with bit switches. It is also possible to specify the address and baud rate with the OR-C configuration software together with the CAB-02 data cable. Note: The new settings only become active after a software reset or power down/up cycle. PRORAMMIN THE Modbus DIP SWITCHES 7600 BACnet 3400 PRORAMMIN THE TRANSMITTER BUS ADDRESS The bus address is programmed with switches DIP SWITCHES to 6 in binary code. Each switch represents a binary value, and the address results from the combination of the individual switches. Examples: Bus address Bit Rate Bit Rate / Bus Bus address Bit Rate Bit Rate 2 ADDRESS 2 ADDRESS 9 Note: When switches 7 and are switched to "", the baud rate address can also be programmed via bus or OR-C configuration software. Note: When all switches are switched to "", the address can also be programmed via bus or the OR-C configuration software. Modbus register The T-MOD-R room sensor supports the following Modbus registers and function codes. The standard communication speed is 9600 bps, data bits, parity Even and Stop bit. The standard Modbus slave address is. The parity can be changed to Odd, None, or Even. The baud rate can be selected between 9600, 9200, 3400 and bps. The baud rate can be selected with the integrated DIP switch or, if switches 7 and (far right) are switched off ( ), via the configuration tool. The sensor addresses to 63 can be programmed with DIP switches to 6. The adjustable range in the configuration tool is from to 7. However, a condition for this is that switches to 6 are set to. Please note that the Modbus register space is specified by the master according to the Modbus application protocol. The Modbus registers for the function codes 02, 03, 06 and represent Modbus address blocks as well as actual Modbus register offsets. For example, the Modbus read register fetches the temperature with function code 04. Some Modbus masters require that function code 04 and register are entered, whereas others query the register with and function code 04. The Modbus addressing begins with 0 (base address). Some Modbus registers begin their addressing with. In this case, you will need to increase the listed register address values by a value of. Register Parameter description Data type Raw data Range FUNCTI CODE 0 READ BITS FUNCTI CODE 05 WRITE E BIT FUNCTI CODE 5 WRITE SEVERAL BITS 0 Overwrite digital output 0 Off On Data bus Overwrite digital output 2 0 Off On Data bus FUNCTI CODE 02 READ INPUT STATES 0000 Status/Digital input 0 Off On 000 Status/Digital input 2 0 Off On 0002 Status/Digital output 0 Off On 0003 Status/Digital output 2 0 Off On Room temperature sensor, active Data sheet No Version

6 Register Parameter description Data type Raw data Range FUNCTI CODE 04 READ INPUT REISTER 3000 Temperature measuring Signed , Currently calculated setpoint ( C / % RH / Lux) or current setpoint setting (no option) C ( F) Signed -,767 +,767-3, ,276.. Actual setpoint or lower.. upper value Analog output Y Unsigned 0, % 3000 Analog output Y2 Unsigned 0, % Analog output Y3 Unsigned 0, % 300 Alarm status Unsigned 3 = normal status 2 = alarm yellow 3 = alarm red 3000 Firmware version Unsigned (not applicable) (not applicable) FUNCTI CODE 03 READ OUTPUT REISTER FUNCTI CODE 06 WRITE E OUTPUT WORD FUNCTI CODE WRITE SEVERAL OUTPUT WORDS Analog output Y bypass value Unsigned 0, V Default Analog output Y2 bypass value Unsigned 0, V Default Analog output Y3 bypass value Unsigned 0, V Default Digital output 2 mode Unsigned = via Modbus (Default) = 2 = Temperature controlled 3 = 4 = 5 = 6 = Pushbutton 4000 Forced reset Unsigned 0 0 = normal = forced reset 400 Update non-volatile memory Unsigned 0 See note 3 0 = normal = update Note : The Modbus address can only be configured by the OR-C tool when bit switches 6 are switched off. Note 2: The Modbus baud rate can only be configured by the OR-C tool when bit switches 7 and are switched off (default setting: 9600 Baud). Note 3: In order to store the changes, Nicht flüchtiger Speicher aktualisiert (Non-volatile memory update) must be set to Update. If you use the OR-C sensor configuration tool, the software will automatically force data storage in the non-volatile portion of memory. 6 7 Room temperature sensor, active Data sheet No Version

7 Drawing scale :2 25 Screw hole locations Wall mounting bracket Lightly press the bottom clip to open housing Dead stop limiter/setpoint potentiometer -P2 The setpoint potentiometer button is set by the factory to rotate at an angle of ± 35. If desired, the rotating angle can be limited in both directions by relocating the dead stop. Do so by cutting off the two pins on the bottom of the rotating button with a knife or box cutter. Insert each of the severed pins into one of the holes designed for this purpose. Oppermann Regelgeräte mbh Im Spitzhau 7077 Leinfelden-Echterdingen, ermany Phone Fax info@oppermann-regelgeraete.de Specifications subject to change. Room temperature sensor, active Data sheet No Version

NC-12 Modbus Application

NC-12 Modbus Application NC-12 Modbus Application NC-12 1 Table of Contents 1 Table of Contents... 2 2 Glossary... 3 SCADA...3 3 NC-12 Modbus in general... 3 4 Entire system... 4 4.1 PFC to PC connection alternatives...4 4.1.1

More information

WEB log. Device connection plans

WEB log. Device connection plans WEB log LIGHT+ 20 BASIC 100 PRO unlimited Device connection plans Version 20160425* Copyright Copyright for this manual remains with the manufacturer. No part of this manual may be reproduced or edited,

More information

T0118 T2118 T3118. Instruction Manual

T0118 T2118 T3118. Instruction Manual Programmable indoor transmitter of temperature T0118 Programmable indoor transmitter of atmospheric pressure T2118 Programmable indoor transmitter of temperature, relative humidity and other derived humidity

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS LIGHTING CONTROL PANELS 4 AND 8 RELAYS INSTALLATION INSTRUCTIONS INSTALLATION OVERVIEW The installation instructions contained in this document are provided as a guide for proper and reliable installation.

More information

Vroom Hardware manual ver. 1.00 Code 114VROOHWE00. Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR

Vroom Hardware manual ver. 1.00 Code 114VROOHWE00. Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR ENGLISH HARDWARE MANUAL ver. 1.00 CODE 114VROOHWE00 page 1 of 22 Important Important Read these instructions

More information

CDR Room CO 2 and Temperature Sensor with BACnet

CDR Room CO 2 and Temperature Sensor with BACnet Product sheet SN1.405 Type CD-BAC CD-BAC oom CO 2 and Temperature Sensors with BACnet The CD-BAC sensors are designed to detect carbon dioxide concentration and temperature in the room spaces and have

More information

Inwall Room Temperature Unit

Inwall Room Temperature Unit Inwall Room Temperature Unit TM11B01KNX TM11B11KNX TM11B21KNX Product Handbook Product: Inwall Room Temperature Unit Order Code: TM11B01KNX TM11B11KNX TM11B21KNX Application Program ETS: TM11B_1KNX Inwall

More information

IPThermo206G. Offline/online data collector, SMS alarm sender, watchdog terminal for IPThermo Pro network

IPThermo206G. Offline/online data collector, SMS alarm sender, watchdog terminal for IPThermo Pro network IPThermo206G Offline/online data collector, SMS alarm sender, watchdog terminal for IPThermo Pro network IPThermo 206G is the central data handling terminal of the IPThermo Pro measurement network. This

More information

AIS750 Series Alarm Annunciator

AIS750 Series Alarm Annunciator Unparallel, modular, multipoint design with Integrated controllers Two Operation Modes (Stand-alone & Serial) All sizes confi gurable up to 440 Alarm Points RS485 / RS232 Serial Communication Manual &

More information

WEB log. Device connection plans

WEB log. Device connection plans WEB log LIGHT+ 20 BASIC 100 PRO unlimited Device connection plans Version 20151210* Copyright Copyright for this manual remains with the manufacturer. No part of this manual may be reproduced or edited,

More information

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency echnical data sheet NV24A--RE Communicative globe valve actuator for 2-way and 3-way globe valves Actuating force 1000 N Nominal voltage AC/DC 24 V Control Modulating DC (0)2...10 V Variable Nominal stroke

More information

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

Automation System TROVIS 6400 TROVIS 6493 Compact Controller Automation System TROVIS 6400 TROVIS 6493 Compact Controller For panel mounting (front frame 48 x 96 mm/1.89 x 3.78 inch) Application Digital controller to automate industrial and process plants for general

More information

Name Description Model Number. Parameters Min. Typ. Max. Note. Vaux Voltage 9.8 V 12 V 13.2 V Auxiliary Supply Voltage

Name Description Model Number. Parameters Min. Typ. Max. Note. Vaux Voltage 9.8 V 12 V 13.2 V Auxiliary Supply Voltage Description Supports DALI interface driver Programming Supports 0-10V Programmable Driver Programming Supports Other Controllers (TDD-ANPNx, SDD-AAPNx) Off-line programming capability Auto programming

More information

BACnet Automation Interface Module (Network Version)

BACnet Automation Interface Module (Network Version) Sense +V Tx Rx LAN LINK Over ARCNET KBaud BACnet Rx BACnet Tx Archive Valid Port S Tx Port S Rx Low Battery Network- Enhanced Access Default MSTP PTP = Download Required on Rnet and Port S IP Address IP

More information

Data logger. Installation and operating instructions. Read carefully before installation, commissioning and operation.

Data logger. Installation and operating instructions. Read carefully before installation, commissioning and operation. Data logger Installation and operating instructions SOREL Connect Read carefully before installation, commissioning and operation 1.1. - Specifications Description of data logger Electrical specifications:

More information

USER S GUIDE. EE210 - Humidity and Temperature Transmitter for demanding Climate Control Applications GENERAL CAUTION CONNECTION DIAGRAM

USER S GUIDE. EE210 - Humidity and Temperature Transmitter for demanding Climate Control Applications GENERAL CAUTION CONNECTION DIAGRAM USER S GUIDE EE210 - Humidity and Temperature Transmitter for demanding Climate Control Applications GENERAL The EE210 transmitter, available for wall or duct mounting, is designed for the highly accurate

More information

Electronic Control Devices The European Product Catalogue 2007

Electronic Control Devices The European Product Catalogue 2007 FX07 Field Controller (1/4) FX07 Field Controller Display Model Dimensions in mm (inches) The FX07 is a terminal unit controller in the Facility Explorer range of products. The controller is designed specifically

More information

T7560A,B,C Digital Wall Module

T7560A,B,C Digital Wall Module T7560A,B,C Digital Wall Module HONEYWELL EXCEL 5000 OPEN SYSTEM BEFORE INSTALLATION All wiring must comply with local electrical codes and ordinances or as specified on installation wiring diagrams. Digital

More information

Duct Humidity Transmitter

Duct Humidity Transmitter SDC-H Duct Humidity Transmitter Features Replaceable sensor element Humidity measurement for air ducts Minimum and maximum value memory 0 0V, 0 0mA or 0V, 4 0mA measuring signals selectable with jumpers

More information

Application/Connection Examples

Application/Connection Examples This Quick Start Guide is designed to familiarize the user with the connection and configuration of the DTS-305 DIN rail mounted single / 3 phase power & energy meter with RS-485 or TCP communications.

More information

Electronic Control Devices The European Product Catalogue 2007

Electronic Control Devices The European Product Catalogue 2007 FX14 Field Controller (1/4) FX14 Field Controller The FX14 is an equipment field controller in the Facility Explorer range of products. The controller is designed specifically for commercial Heating, Ventilating,

More information

Controls for fan coil units and cassettes

Controls for fan coil units and cassettes Controls for fan coil units and cassettes Selection of controls for use with fan coil & cassette units. Stand alone, selection guide Control unit Motor Standard QZAZ-04-10 QZAZ-04-20 QZAZ-04-75 QZAZ-05-11

More information

Product and Application Description

Product and Application Description Technical Product - Information Product and Application Description The room temperature controller UP 237K and UP 252K are available in the following colors, matching the design of the wall switch design

More information

FX07 Field Controller

FX07 Field Controller Product Bulletin FX07 Field Controller Issue Date March 25, 2008 FX07 Field Controller The FX07 is a high performance field controller designed specifically for commercial Heating, Ventilating, Air Conditioning,

More information

PK-01. Standalone door control module. SATEL sp. z o.o. ul. Schuberta 79 80-172 Gdańsk POLAND tel. + 48 58 320 94 00

PK-01. Standalone door control module. SATEL sp. z o.o. ul. Schuberta 79 80-172 Gdańsk POLAND tel. + 48 58 320 94 00 Standalone door control module PK-01 Firmware version 1.00 pk-01_en 06/12 SATEL sp. z o.o. ul. Schuberta 79 80-172 Gdańsk POLAND tel. + 48 58 320 94 00 info@satel.pl www.satel.eu WARNINGS Read carefully

More information

Modular I/O System Analog and Digital Interface Modules

Modular I/O System Analog and Digital Interface Modules OPERATING INSTRUCTIONS Modular I/O System Analog and Digital Interface Modules Installation Operation Maintenance Document Information Document ID Title: Operating Instructions Modular I/O System Part

More information

Temp. & humidity Transmitter Instructions

Temp. & humidity Transmitter Instructions Temp. & humidity Transmitter Instructions AQ3485/AQ3485Y www.aosong.com 1 Product Overview AQ3485/ AQ3485Y outdoor network temperature and humidity transmitter is accurate measurement of relative humidity

More information

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2 Type code Ident no. 1545065 Number of channels 2 Dimensions (W x L x H) 108 x 145 x 77.5 mm CoDeSys-programmable acc. to IEC 61131-3 Cable max. 50 m between interface and read/write head 10/100 Mbps Male

More information

Introduction. Refrigerant Leak Detecting System. Feature and Benefits

Introduction. Refrigerant Leak Detecting System. Feature and Benefits PSC European Refrigeration Controls Catalogue Catalog Section 9 Product Bulletin PD-GAS-E Refrigerant Leak Detecting System Introduction This range of refrigerant leak detecting systems is designed for

More information

IntesisBox KNX Mitsubishi Heavy Industries AC

IntesisBox KNX Mitsubishi Heavy Industries AC IntesisBox KNX Mitsubishi Heavy Industries AC Gateway for integration of Mitsubishi Heavy Indsutries (MHI) Air Conditioners with KNX control systems. 1. Main Features Direct connection to KNX TP-1 (EIB)

More information

HMI display Installation Guide

HMI display Installation Guide HMI display Installation Guide Product Description Specifications Important Information o Package Contents o Related Documents o Accessories Cautions and Warnings Mounting and Dimensions o BAC-DIS-ENC

More information

IntesisBox KNX LG Air Conditioning

IntesisBox KNX LG Air Conditioning IntesisBox KNX LG Air Conditioning Gateway for integration of LG Air Conditioners with KNX control systems. 1. Main Features Direct connection to KNX TP-1 (EIB) bus. Direct connection to LG outdoor unit

More information

PK5500 v1.1 Installation Instructions

PK5500 v1.1 Installation Instructions PK5500 v1.1 Installation Instructions 1 2 3 4 5 6 7 8 9 * 0 # WARNING: Please refer to the System Installation Manual for information on limitations regarding product use and function and information on

More information

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply) transmitter (2 wire) / switch for continuous or On/Off Control Indication, monitoring, transmitting and continuous or On/Off control in one device Output signal 4...20 ma, 2-wire for continuous control

More information

How To Use A Power Supply On A Powerline 2.2 (Ai)

How To Use A Power Supply On A Powerline 2.2 (Ai) KNX/EIB Product documentation Issue: 05.08.2010 629x1220 Push button sensor 3 comfort 1-gang Push button sensor 3 comfort 2-gang (1+1) Push button sensor 3 comfort 3-gang Push button sensor 3 comfort 4-gang

More information

PCS0100en 02.2008. Persy Control Services B.V. Netherlands

PCS0100en 02.2008. Persy Control Services B.V. Netherlands P-Bus Gateway PBGW2.128 Universal gateway between the P-bus protocol and open standard protocols. The variety of available electrical interfaces on the gateway offers a wide range of possibilities for

More information

TAC I/NETTM MR-VAV-AX. Application Specific MicroRegulator TM

TAC I/NETTM MR-VAV-AX. Application Specific MicroRegulator TM TAC I/NETTM TM TAC s TM has an extensive range ofpre-engineered VAV control sequences, which combined with a fully integrated actuator and airflow transducer, makes it a low Total Installed Cost solution

More information

Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5

Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5 Model Number Single head system Features Parameterization interface for the application-specific adjustment of the sensor setting via the service program ULTRA 000 programmable switch outputs Hysteresis

More information

GREISINGER electronic GmbH

GREISINGER electronic GmbH T38.0.0X.6C-03 CO2 - Transmitter Operating Manual GT10 - CO2-1R GREISINGER electronic GmbH D - 93128 Regenstauf, Hans-Sachs-Straße 26 Tel.: +49 9402 / 9383-0, Fax: +49 9402 / 9383-33, email: info@greisinger.de

More information

Technical Manual. FAN COIL CONTROLLER COOLING or HEATING ANALOG or PWM Art. 119914 631001A

Technical Manual. FAN COIL CONTROLLER COOLING or HEATING ANALOG or PWM Art. 119914 631001A COOLING or HEATING ANALOG or PWM Art. 119914 631001A TOTAL AUTOMATION GENERAL TRADING CO. LLC SUITE NO.506, LE SOLARIUM OFFICE TOWER, SILICON OASIS, DUBAI. UAE. Tel. +971 4 392 6860, Fax. +971 4 392 6850

More information

PowerLogic Sub Meter Display (SMD and SMDOPN)

PowerLogic Sub Meter Display (SMD and SMDOPN) Instruction Bulletin Z203742-0B PowerLogic Sub Display (SMD and SMDOPN) CONTENTS Introduction... 2 Parts of the Sub Display... 3 Dimensional Drawing... 4 Installation... 5 Mounting the SMD... 5 Mounting

More information

Room Controllers. SER8300 Line Voltage Fan Coil Room Controller with SC3000 Relay Pack

Room Controllers. SER8300 Line Voltage Fan Coil Room Controller with SC3000 Relay Pack Compatible with SmartStruxure solution SmartStruxure Lite solution Room Controllers Line Voltage Fan Coil Room Controller with SC3000 Relay Pack Application specific controller with customizable covers

More information

PolyGard Carbon Monoxide CO Transmitter ADTX3 1110

PolyGard Carbon Monoxide CO Transmitter ADTX3 1110 PolyGard Carbon Monoxide CO Transmitter ADTX3 1110 DESCRIPTION CO transmitter including digital measurement value processing and temperature compensation for the continuous monitoring of the ambient air

More information

RI-215A Operator s Manual. Part Number: 71-0045RK Revision 0 Released: 10/3/05

RI-215A Operator s Manual. Part Number: 71-0045RK Revision 0 Released: 10/3/05 RI-215A Operator s Manual Part Number: 71-0045RK Revision 0 Released: 10/3/05 Warranty RKI Instruments, Inc., warrants gas alarm equipment sold by us to be free from defects in materials and workmanship,

More information

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q605 0054 R0001

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q605 0054 R0001 Analogue Input, -fold, MDRC, GH Q605 005 R0001 The analogue input is a DIN rail mounted device for insertion in the distribution board. It is connected to the EIB via the bus connecting terminal supplied.

More information

e-4 AWT07MLED 7 Q TFT LCD MONITOR (LED Backlighted) USER MANUAL

e-4 AWT07MLED 7 Q TFT LCD MONITOR (LED Backlighted) USER MANUAL Thank you for purchasing our product. Please read this User s Manual before using the product. Change without Notice AWT07MLED 7 Q TFT LCD MONITOR (LED Backlighted) USER MANUAL e-4 SAFETY PRECAUTIONS Federal

More information

Troubleshooting and Diagnostics

Troubleshooting and Diagnostics Troubleshooting and Diagnostics The troubleshooting and diagnostics guide provides instructions to assist in tracking down the source of many basic controller installation problems. If there is a problem

More information

1 Technical Description Lokal-200PC

1 Technical Description Lokal-200PC 1 Technical Description Lokal-200PC 1.1 Overview laptop with in-built accummulator USB connection correlator box internal power supply laptop (if the device has been supplied by F.A.S.T.) BNC aerial connection

More information

Addendum to the Operating Instructions

Addendum to the Operating Instructions Drive Technology \ Drive Automation \ System Integration \ Services Addendum to the Operating Instructions MOVIMOT with AS-Interface and AC Motor DT/DV Unit Replacement MOVIMOT MM..C -> MM..D with MLK3A

More information

Product and functional description

Product and functional description Product and functional description The KNX / DALI gateway N 141/02 is a 4 MU wide, DINrail mounted KNX device with one DALI interface to which up to 64 DALI actuators (e.g. DALI ballasts) can be connected

More information

User Manual. Humidity-Temperature Chart Recorder. Model RH520

User Manual. Humidity-Temperature Chart Recorder. Model RH520 User Manual Humidity-Temperature Chart Recorder Model RH520 Introduction Congratulations on your purchase of the Extech RH520 Temperature + Humidity Chart Recorder. The RH520 measures and displays Temperature,

More information

FLOW CALCULATOR INSTRUCTION MANUAL MESURES BAMOPHOX 759 26-06-2007 759 M1 02 E MES FLOW CALCULATOR 759-02/1

FLOW CALCULATOR INSTRUCTION MANUAL MESURES BAMOPHOX 759 26-06-2007 759 M1 02 E MES FLOW CALCULATOR 759-02/1 BAMOPHOX 759 E - M FLOW CALCULATOR INSTRUCTION MANUAL MESURES 22, Rue de la Voie des Bans - Z.I. de la Gare - 95100 ARGENTEUIL Tél : (33) 01 30 25 83 20 - Web : www.bamo.fr Fax : (33) 01 34 10 16 05 -

More information

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER Application : The RISH CON - Hz transducer is used for frequency measurement. The output signal is proportional to measured frequency and is either load independent DC Current or load independent DC Voltage.

More information

TC-9102 Series Surface Mount Temperature Controllers

TC-9102 Series Surface Mount Temperature Controllers TC-9102 Series Surface Mount Temperature Controllers General Description & Applications The TC-9102 Series Temperature Controller offers a versatile solution for a wide variety of applications that may

More information

Installation and Operation Manual. Digital Remote Meter for Monitoring System Performance. Version: RM-1

Installation and Operation Manual. Digital Remote Meter for Monitoring System Performance. Version: RM-1 REMOTE METER TM Installation and Operation Manual. Digital Remote Meter for Monitoring System Performance. Version: RM-1 1098 Washington Crossing Road Washington Crossing, PA 18977 USA www.morningstarcorp.com

More information

SYSTEM 4C. C R H Electronics Design

SYSTEM 4C. C R H Electronics Design SYSTEM 4C C R H Electronics Design SYSTEM 4C All in one modular 4 axis CNC drive board By C R Harding Specifications Main PCB & Input PCB Available with up to 4 Axis X, Y, Z, A outputs. Independent 25

More information

SYSTEM 45. C R H Electronics Design

SYSTEM 45. C R H Electronics Design SYSTEM 45 C R H Electronics Design SYSTEM 45 All in one modular 4 axis CNC drive board By C R Harding Specifications Main PCB & Input PCB Available with up to 4 Axis X, Y, Z, & A outputs. Independent 25

More information

Mirror Mount Video Monitor/Recorder with Front and Rear View Night Cameras PLCMDVR5

Mirror Mount Video Monitor/Recorder with Front and Rear View Night Cameras PLCMDVR5 Mirror Mount Video Monitor/Recorder with Front and Rear View Night Cameras PLCMDVR5 www.pyleaudio.com Instruction Manual Installation and Connection: 1. Please disconnect your car battery. 2. In the contents

More information

ABB Drives. User s Manual HTL Encoder Interface FEN-31

ABB Drives. User s Manual HTL Encoder Interface FEN-31 ABB Drives User s Manual HTL Encoder Interface FEN-31 HTL Encoder Interface FEN-31 User s Manual 3AUA0000031044 Rev B EN EFFECTIVE: 2010-04-06 2010 ABB Oy. All Rights Reserved. 5 Safety instructions

More information

PD 100A. Printing data system

PD 100A. Printing data system PD 100A Printing data system Operating instructions ENGLISH IMPORTANT: Read these instructions carefully before installing and using the device; do not forget following all additional information. Keep

More information

Disclaimers. Important Notice

Disclaimers. Important Notice Disclaimers Disclaimers Important Notice Copyright SolarEdge Inc. All rights reserved. No part of this document may be reproduced, stored in a retrieval system, or transmitted, in any form or by any means,

More information

T5000 T000 LCD Digital Fan Coil Thermostat

T5000 T000 LCD Digital Fan Coil Thermostat T5000 T000 LCD Digital Fan Coil Thermostat T000 LCD Digital Fan Coil Thermostat T000 LCD Digital Fan Coil Thermostats are designed to control heating, cooling, or year round air conditioning unit in Commercial,

More information

Wind Sensor W-RS485 with RS485 Interface

Wind Sensor W-RS485 with RS485 Interface Wind Sensor W-RS485 with RS485 Interface Technical data and notes for installation Elsner Elektronik GmbH Steuerungs- und Automatisierungstechnik Herdweg 7 D-75391 Gechingen Germany Phone: +49 (0) 70 56/93

More information

Modbus Server SAMSUNG Air Conditioners

Modbus Server SAMSUNG Air Conditioners IntesisBox Server SAMSUNG Air Conditioners Gateway for monitoring and control of Samsung Air Conditioning Systems from any master device TCP or RTU (BMS, PLC, SCADA, HMI, TouchPanel ) Master TCP Master

More information

WD-AMX Water Detection Controllers

WD-AMX Water Detection Controllers Page 1 of 5 WD-AMX Water Detection Controllers Features: Benefit: LED Status of leak status VFC output Audible alarm Auto or manual reset alarm output Uses an isolated AC signal which prevents oxidation

More information

INTMOD485-LH Protocol Converter

INTMOD485-LH Protocol Converter For Use with L-GAGE LH Series Sensors Features Converts an LH Network to the 485-RTU protocol Supports baud rates up to 230,400 baud Supports LH Networks with up to 32 sensors Model Protocol Conversion

More information

Bluetooth HC-06 with serial port module Easy guide

Bluetooth HC-06 with serial port module Easy guide 1 Bluetooth HC-06 with serial port module Easy guide This manual consists of 3 parts: PART 1. Overview of Bluetooth HC-06 module with serial port. PART 2. Installing Bluetooth HC-06 module with Bolt 18F2550

More information

IntesisBox KNX Modbus RTU master

IntesisBox KNX Modbus RTU master IntesisBox KNX RTU master Gateway for integration of RTU devices into KNX control systems. Integrate RTU devices (Chillers, Roof Tops, electricity meters, heating floors, heat pumps, PLCs ) into KNX control

More information

16-Port RS232 to USB2.0 High Speed Multi Serial Adapter (w/ Metal Case) Installation Guide

16-Port RS232 to USB2.0 High Speed Multi Serial Adapter (w/ Metal Case) Installation Guide 16-Port RS232 to USB2.0 High Speed Multi Serial Adapter (w/ Metal Case) Installation Guide 1. Introduction Thank you for purchasing this 16-Port RS232 to USB2.0 High Speed Multi Serial Adapter. It is an

More information

Ventostat Wall Mount. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. GE Measurement & Control. Features:

Ventostat Wall Mount. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. GE Measurement & Control. Features: GE Measurement & Control Ventostat Wall Mount Telaire Wall Mount, Humidity and Temperature Transmitters Features: Patented, Absorption Infrared Gas sensing engine provides high accuracy in a compact low

More information

User Guide Reflow Toaster Oven Controller

User Guide Reflow Toaster Oven Controller User Guide Reflow Toaster Oven Controller Version 1.5-01/10/12 DROTEK Web shop: www.drotek.fr SOMMAIRE 1. Introduction... 3 2. Preparation of THE REFLOW CONTROLLER... 4 2.1. Power supply... 4 2.2. USB

More information

KNX TH65-AP. Thermo-Hygrometer. Technical specifications and installation instructions Item number 70184

KNX TH65-AP. Thermo-Hygrometer. Technical specifications and installation instructions Item number 70184 EN KNX TH65-AP Thermo-Hygrometer Technical specifications and installation instructions Item number 70184 Elsner Elektronik GmbH Control and Automation Engineering Herdweg 7 D 75391 Gechingen Phone +49

More information

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems 3 072 RDJ10RF RCR10/433 Wireless room temperature controller with 24-hour time switch and LCD Programmable, for heating systems RDJ10RF/SET Operating modes: Automatic, Comfort, Energy Saving, and Frost

More information

TABLE 1: Wiring Terminals. Connect to... 1C 1H 2C 2H 1H1C 2H1C 2H2C 3H2C

TABLE 1: Wiring Terminals. Connect to... 1C 1H 2C 2H 1H1C 2H1C 2H2C 3H2C Installation TURN OFF POWER TO THE SYSTEM AT THE MAIN POWER PANEL TO AVOID ELECTRICAL SHOCK. Installation should be carried out by an electrician or a qualified technician. 1.1 Find a Location for the

More information

IntesisBox Modbus Server SAMSUNG Air Conditioners

IntesisBox Modbus Server SAMSUNG Air Conditioners IntesisBox Modbus Server SAMSUNG Air Conditioners Gateway for monitoring and control of Samsung NASA compatible Air Conditioning Systems from any Modbus master device TCP or RTU (BMS, PLC, SCADA, HMI,

More information

Tubular Analog model resolution: 0,5 mm (SLOW mode), 1 mm (FAST mode) Right angle Repeatibility: 0,7 mm Vdc

Tubular Analog model resolution: 0,5 mm (SLOW mode), 1 mm (FAST mode) Right angle Repeatibility: 0,7 mm Vdc Ultrasonic sensors for high precision detection of clear and transparent objects Clear object detection, inspection on transparent or highly reflective film and liquid level measurement Standard M18 tubular

More information

User's Guide. Integrating Sound Level Datalogger. Model 407780. Introduction

User's Guide. Integrating Sound Level Datalogger. Model 407780. Introduction User's Guide 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Back to the Extech 407780 Product Page Integrating Sound Level Datalogger

More information

FX07 Field Controller

FX07 Field Controller Product Bulletin FX07 Field Controller Issue Date May 5, 2011 FX07 Field Controller The FX07 is a high performance field controller designed specifically for commercial Heating, Ventilating, Air Conditioning,

More information

KNX L. Brightness Sensor. Technical specifications and installation instructions Item number 70119

KNX L. Brightness Sensor. Technical specifications and installation instructions Item number 70119 EN KNX L Brightness Sensor Technical specifications and installation instructions Item number 70119 Elsner Elektronik GmbH Control and Automation Engineering Herdweg 7 D 75391 Gechingen Phone +49 (0) 70

More information

INSTALLATION MANUAL XM3 Reader

INSTALLATION MANUAL XM3 Reader INSTALLATION MANUAL XM3 Reader Conditions Transactions, deliveries et cetera will be according to the general terms of delivery as deposited at the Chamber of Commerce at Meppel, The Netherlands. Registration

More information

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF Daker DK 1, 2, 3 kva Manuel d installation Installation manual Part. LE05334AC-07/13-01 GF Daker DK 1, 2, 3 kva Index 1 Introduction 24 2 Conditions of use 24 3 LCD Panel 25 4 Installation 28 5 UPS communicator

More information

Instruction Manual. T3111 T3111L T3111P T3111Ex

Instruction Manual. T3111 T3111L T3111P T3111Ex www.cometsystem.cz Instruction Manual T3111 T3111L T3111P T3111Ex Programmable transmitter of temperature, relative humidity and other calculated humidity values with external probe and 4-20 ma outputs

More information

1. SAFETY INFORMATION

1. SAFETY INFORMATION RS-232 Sound Level Meter 72-860A INSTRUCTION MANUAL www.tenma.com 1. SAFETY INFORMATION Read the following safety information carefully before attempting to operate or service the meter. Use the meter

More information

ModBus Server - KNX. Gateway for integration of KNX equipment into Modbus (RTU and TCP) control systems.

ModBus Server - KNX. Gateway for integration of KNX equipment into Modbus (RTU and TCP) control systems. IntesisBox ModBus Server - KNX Gateway for integration of KNX equipment into Modbus (RTU and TCP) control systems. Integrate KNX based lighting control into your SCADA, BMS, PLC "talking" Modbus. Master

More information

Solar Home System. User Manual. AEH-SHS01-10W2L Solar Home System 2 Lamps

Solar Home System. User Manual. AEH-SHS01-10W2L Solar Home System 2 Lamps Solar Home System User Manual AEHSHS0110W2L Solar Home System 2 Lamps All rights reserved Specifications subject to change without prior notice 2 Dear Customer, Thank you for purchasing Schneider Electric

More information

Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION

Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION Modular, Customizable Wire Replacement 128 / 256 Bit AES Encryption Software Selectable RF Transmit Power Software Selectable Over-the-air Data Rate Modbus ASCII /RTU Compatible Wide Operating Temperature

More information

T3 Mux M13 Multiplexer

T3 Mux M13 Multiplexer T3 Mux M13 Multiplexer User Manual [Type the abstract of the document here. The abstract is typically a short summary of the contents of the document. Type the abstract of the document here. The abstract

More information

PRODUCTIVITY THROUGH INNOVATION 600 CONTROL DIRECT DRIVE TECHNICAL/OPERATION MANUAL

PRODUCTIVITY THROUGH INNOVATION 600 CONTROL DIRECT DRIVE TECHNICAL/OPERATION MANUAL Rev. D PRODUCTIVITY THROUGH INNOVATION 600 CONTROL DIRECT DRIVE TECHNICAL/OPERATION MANUAL 10 BORIGHT AVENUE, KENILWORTH NEW JERSEY 07033 TELEPHONE: 800-524-0273 FAX: 908-686-9317 TABLE OF CONTENTS Page

More information

P03/3-Modbus and P03/3-Mod bus-gps

P03/3-Modbus and P03/3-Mod bus-gps EN P03/3-Modbus and P03/3-Mod bus-gps Weather Stations for Mod bus Technical specifications and installation instructions from version 2.0 Elsner Elektronik GmbH Control and Automation Engineering Herdweg

More information

ZC-24DO CANopen I/O Module: 24 Digital Outputs

ZC-24DO CANopen I/O Module: 24 Digital Outputs Z-PC Line EN ZC-24DO CANopen I/O Module: 24 Digital Outputs Installation Manual Contents: - General Specifications - Technical Specifications - Installation Rules - Electrical connections - DIP-switches

More information

Digital input modules

Digital input modules 8 172 TX-I/O Digital input modules TXM1.8D TXM1.16D Two fully compatible versions: TXM1.8D: 8 inputs, each with a three-color LED (green, yellow or red) TXM1.16D: As TXM1.8X, but 16 inputs, each with a

More information

RC2200DK Demonstration Kit User Manual

RC2200DK Demonstration Kit User Manual Demonstration Kit User Manual Table of contents TABLE OF CONTENTS... 1 QUICK INTRODUCTION... 2 INTRODUCTION... 3 DEMONSTRATION BOARD... 4 POWER SUPPLY SECTION... 5 RS-232 INTERFACE... 6 CONNECTORS... 7

More information

Technical data. General specifications. Signal voltage 15... 30 V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output.

Technical data. General specifications. Signal voltage 15... 30 V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output. Model Number Features Very small housing High climatic resistance 4 Bit multiturn Analog output Surge and reverse polarity protection Description This absolute rotary encoder with internal magnetic sampling

More information

ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01

ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01 ABB Drives User s Manual Pulse Encoder Interface Module RTAC-0 Pulse Encoder Interface Module RTAC-0 User s Manual 3AFE 64486853 REV A EN EFFECTIVE:.5.00 00 ABB Oy. All Rights Reserved. Safety instructions

More information

Short Range Wireless Switch System Handheld 8 Installation and Operations Guide

Short Range Wireless Switch System Handheld 8 Installation and Operations Guide Phone: (866) 701-1146 Fax: (425) 216-7558 www.remotecontroltech.com Short Range Wireless Switch System Handheld 8 Installation and Operations Guide Introduction... 2 Before Installation... 2 Receiver Installation...

More information

User Manual Revision 1.400 English Converter / Adapter Ethernet to RS232 / RS485 (Order Code: HD67038-2 HD67038-2-M HD67038-25 HD67038-25-M)

User Manual Revision 1.400 English Converter / Adapter Ethernet to RS232 / RS485 (Order Code: HD67038-2 HD67038-2-M HD67038-25 HD67038-25-M) Document code: MN67038-2_ENG Revision 1.400 Page 1 of 25 User Manual Revision 1.400 English Converter / Adapter Ethernet to RS232 / RS485 (Order Code: HD67038-2 HD67038-2-M HD67038-25 HD67038-25-M) for

More information

How To Use A Pkn10 (Powerline) With A Microsd Card (Powerkit) On A Powerline (Powergen) Or Powerline 2 (Powerbee) (Powerbmi) (Pk10) (Operating

How To Use A Pkn10 (Powerline) With A Microsd Card (Powerkit) On A Powerline (Powergen) Or Powerline 2 (Powerbee) (Powerbmi) (Pk10) (Operating GB PKN10 serial node with colour LCD display User s manual Bač 49a, 6253 Knežak, SLOVENIA tel: ++ 386 5 753 2006 fax: ++ 386 5 753 2007 email: sec.electronics@siol.net http://www.secelectro.com SEC Electronics

More information

User Manual. EtherUSB

User Manual. EtherUSB User Manual EtherUSB USB Ethernet Access Point for PDA V 2.0 Clarinet Systems, Inc. Clarinet Systems, Inc. http://www.clarinetsys.com Page 1 Publication Revision No. Control Table Rev. No. Date Contents

More information

Model SRMD Setra Remote Monitoring Display

Model SRMD Setra Remote Monitoring Display Model SRMD Setra Remote Monitoring Display 1.0 GENERAL INFORMATION Thank you for purchasing the Setra Remote Monitoring Display (SRMD). The SRMD is a digital panel meter with a bright 1 LED display for

More information

Model 201 Wiegand Touchpad Reader Installation Guide

Model 201 Wiegand Touchpad Reader Installation Guide Model 201 Wiegand Touchpad Reader Installation Guide P/N 460353001C 15AUG11 2011 UTC Fire & Security. All rights reserved. This document may not be copied in whole or in part or otherwise reproduced without

More information