Controls for fan coil units and cassettes

Size: px
Start display at page:

Download "Controls for fan coil units and cassettes"

Transcription

1 Controls for fan coil units and cassettes Selection of controls for use with fan coil & cassette units. Stand alone, selection guide Control unit Motor Standard QZAZ QZAZ QZAZ QZAZ QZAZ QZAZ QZAZ STRA-07 + STRZ-14 STRA-17 ECM Location Wall mounted Built-in Fan speed Valves Manual Automatic Cooling Electrical Heating heater Season mode manual automatic With communication, selection guide Control unit Motor Standard ECM QZAZ QZAZ-12-bb QZAZ QZAZ-12-bb STRA-07 + STRZ-14 STRA-17 Location Wall IR mounted remote 1 (18) Communication Modbus BacNet Fan speed Valves Manual Automatic Cooling Electrical Heating heater

2 Built-in room controllers Built-in controls for fan coil units with decorative cabinet QZBF, QZBT and QZBM Control equipment is delivered separately and not mounted on the unit. QZAZ Three speed selector switch Applications Manual control of fan operation, no thermostatic control - ON-OFF switch - Manual 3 speed switch - For standard motor QZAZ Integrated thermostat with manual speed control Applications Manual speed control for 2-pipe, 4-pipe & 2-pipe with electrical heater. - ON-OFF switch - Manual 3 speed switch - Summer/Winter switch - Electronic room thermostat for fan or valves control (ON/OFF) - Control of the chilled water valve (ON/OFF) and the heating electric resistance, only in case that the coil is not fed with warm water in winter - For standard motor 20 C 2 (18)

3 QZAZ Integrated thermostat with auto speed control Applications Automatic or manual speed control for 2-pipe, 4-pipe & 2-pipe with electrical heater. - ON-OFF switch - Manual or automatic 3 speeds fan control switch - Manual (switch) or automatic switching of season mode (Summer/Winter) - Electronic room thermostat for fan or valves control (ON/OFF) - Control the chilled water valve (ON-OFF) and the heating electric resistance only in case that the coil is not fed with warm water in winter - For standard motor QZAZ Integrated thermostat with auto speed control for EC-motor Applications Automatic or manual speed control for 2-pipe, 4-pipe, 2-pipe with electrical heater - ON-OFF switch - Manual 3 speed or automatic continuous speed control switch. - Manual Summer/Winter switch - Electronic room thermostat for fan or valves control (ON/OFF) - Simultaneous thermostatic control of the valves and fan - For EC-motor 3 (18)

4 Wall mounted room controller Wall mounted controls for fan coil units - QZBA, ductable units QZSR / QZHR, and cassettes QFDK / QZCC QZAZ Three speed selector for standard motor Applications Manual control of fan operation, no thermostatic control - ON-OFF switch - Manual 3 speed switch - For standard motor QZAZ Room thermostat with manual speed control for standard motor Applications Manual speed control for 2-pipe, 4-pipe & 2-pipe with electrical heater. - ON-OFF switch - Manual 3 speed switch - Manual (switch) or automatic switching of season mode (Summer/Winter) - Electronic room thermostat for fan or valves control(on/off) - Control of the chilled water valve (ON/OFF) and the heating electric resistance, only in case that the coil is not fed with warm water in winter - For standard motor For a Master/Slave configuration of the QZAZ a speed switch is required: QZAZ for QFDK, QZHR - For QZHR controlled as stand-alone unit the speed switch QZAZ is used to connect multiple motors. QZHR size 33-66, 1x QZAZ QZHR size 74-76, 2x QZAZ QZAZ for QZSR, QZCC, QZB QZAZ for QZHW 4 (18)

5 Room thermostat with auto speed control for standard and EC motor Applications QZAZ Automatic or manual speed control for 2-pipe, 4-pipe & 2-pipe with electrical heater - ON-OFF switch - Manual or automatic 3 speeds fan control switch. - Manual (switch) or automatic switching of season mode (Summer/Winter) - Electronic room thermostat for fan or valves control(on/off) - Control of the chilled water valve (ON/OFF) and the heating electric resistance, only in case that the coil is not fed with warm water in winter - For standard & EC-motor Applications QZAZ Automatic or manual speed control for 2-pipe, 4-pipe & 2-pipe with electrical heater - ON-OFF switch. - Manual or automatic 3 speeds fan control switch. - Temperature setting. - Operation mode setting (fan only, cooling, heating; auto for 4 pipe systems with mode selection depending on the air temperature). - Manual, centralized or automatic Summer/Winter switch - Weekly ON/OFF program. - Time setting. - For standard & EC-motor Power unit to be installed on the fan coil (fan coil interface). It controls the fan and the valves of the fan coil. The power unit is connected to the electric supply. The power unit receives the information required from the control. It is used with the room thermostat QZAZ and QZAZ QZAZ-05-77, supplied loose QZAZ-05-78, factory fitted QZAZ is always used together with power unit QZAZ-05-77/78. QZAZ can control up to 10 fan coils and then a power unit is used for each fan coils. 5 (18)

6 Infra red remote control QZAZ The infra-red remote control QZAZ allows setting of the fan coil operation parameters from a remote position. - ON-OFF switch. - Temperature setting. - Manual or automatic 3 speeds fan control switch. - Set the operation mode (fan only, cooling, heating; auto for 4 pipe systems with mode selection depending on the air temperature). - Time setting hours ON/OFF program. - For standard & EC-motor Application/Control operations: am Clock 24 hours 00:00pm Timer: the program switches the divice on and off Displays the temperature set point Fan speed setting: 3 speeds plus automatic selection Operating mode: heat/cool/fan only plus automatic mode selection Product QZBF/M/T QZBA, QZSR, QZCC and QFDK with QFDZ-10 QFDK with QFDZ-15 QZHW Mounted IR receiver QZAZ Included in QZHW-aa-1-c-d-e C A A Not mounted IR receiver QZAZ QZAZ QZAZ-05-98, for QZHW-aa-2-c-d-e One control for more units (20 units max.) (MAXIMUM TOTAL LENGTH OF THE CONNECTION CABLE = 800 m) One control for each unit TIMER START STOP CLOCKSET SET TEMP 6 (18)

7 With modbus communication, technical data QZAZ Wall mounted room controller with display that allows controlling one or more units in Master/Slave mode. The control is equipped with internal sensor to detect the room temperature, which can be defined as a priority compared to the return air sensor on the fan coil. The QZAZ must be used together with electric board and it features the following functions: Applications QZAZ Automatic or manual speed control for 2-pipe, 4-pipe & 2-pipe with electrical heater - ON-OFF switch. - Manual or automatic 3 speeds fan control switch. - Temperature setting. - Manual, centralized or automatic Summer/Winter switch - Operation mode setting (fan only, cooling, heating; auto for 4 pipe systems with mode selection depending on the air temperature). - Weekly ON/OFF program. - Time setting. - For standard & EC-motor QZAZ-12-bb The electric board is used to get Modbus RTU-RS 485 communication and to carry out different functions and adjustment modes. The electric board is used either together with wall mounted QZAZ or Infra red remote control. These modes are selected by setting the configuration dip switches on the board: - 2/4 pipe system - Fan ON/OFF thermostatic control - Valve ON/OFF thermostatic control and continuous ventilation - Valve and simultaneous ventilation ON/OFF thermostatic control - Fan operation control depending on the coil temperature (cut-out probe fitted), which can be activated only in heating mode or heating and cooling mode - Automatic switch of the operating mode by means of water probe QZAZ (optional) applied on the 2 pipe system - Seasonal switch by means of remote contact - ON/OFF of the fan coil by means of the remote contact (window or clock contact) - Electric heater control By activating the cut-out probe function, the fan is stopped in winter when the coil temperature is lower than 32 C and started when the temperature reaches 36 C. In summer mode, the fan stops when the temperature inside the coil exceeds 22 C and starts when it drops below 18 C. The following connections are located on the power board: Receiver for infra-red remote control QZAZ wall mounted control RS 485 serial connection to manage several fan coils in Master/Slave configuration or to create a supervisory network. The electric board is included in the QFDK and QZHW. For QZB, QZSR and QZCC it can be ordered as an accessory. - QZB, QZSR, QZCC Standard motor Mounted unit QZAZ ECM motor Not mounted unit QZAZ Mounted unit QZAZ Not mounted unit QZAZ A group of units with electric control board can be connected via a serial link and can consequently be managed at the same time by just one QZAZ wall control. By cons the group of units can t be connected to a BMS though the Modbus communication. 7 (18)

8 Using the special jumper present on the board, one unit must be configured as the master, and all the others as slaves. It is clear that the remote control must be pointed at the receiver on the master unit. To avoid problems, it is recommended to install and connect the receiver only on the master unit. One control for each unit One control for more units (20 units max.) (MAXIMUM LENGTH OF THE CONNECTION CABLE = (MAXIMUM TOTAL LENGTH OF THE CONNECTION 20 m) CABLE = 800 m) 8 (18)

9 QZAZ-01-bb Accessories QZAZ Low temperature cut-out thermostat Funtions - For units working on heating only, installed in contact with hot water circuit - Stops the fan when water temperature is lower than 30 C and starts the fan when water temperature is higher than 38 C Used with QZAZ & QZAZ QZAZ Change-over sensor CH Automatic summer/winter switch to be installed in contact with the water circuit - For 2-tube installations only (not to be used with 2 way valve) Used together with QZAZ QZAZ T2 sensor to be placed on the water supply pipe upstream 3 way valves (not to be used with 2 way valve) The QZAZ sensor can be combined with MB boards to be placed on the water supply pipe upstream 3 way valves (not to be used with 2 way valve). The QZAZ sensor must be used as described below: - Change-Over for 2-pipe system for the automatic switch of the operating mode. If water temperature is lower than 20 C, cooling mode is set; on the other hand, if water temperature exceeds 30 C, heating mode is set. - It can be used on units with electric heater and hot water supply. The T2 priority probe activates the electric heater or water valve, depending on the water temperature detected. If water temperature exceeds 34 C, the water valve ON-OFF control is activated; on the other hand, if water temperature is lower than 30 C, the electric heater is activated. Used with QZAZ-05-77/78 9 (18)

10 Application examples Standalone Manual 3-speed control AC-motor Standalone Manual 3-speed control with heating/cooling AC motor 10 (18)

11 Master-slave Manual 3-speed control with heating cooling AC motor Standalone/Master-slave automatic fan control, heating cooling for both AC/EC motor 11 (18)

12 Standalone/Master-slave with Modbus automatic fan control, heating cooling for both AC/ EC motor IR Standalone/Master-slave with Modbus automatic fan control, heating cooling for both AC/EC motor 12 (18)

13 Room controller STRA-07 and STRA-17 STRA-07/17 is a preprogrammed room controller intended to control heating and cooling in after-treatment systems. It is preprogrammed with communication and is intended for use in premises where high comfort and low energy consumption is aimed, e.g. offices, schools, shopping centres, airports, hotels, hospitals and so on. Room controller description Communication via RS485 (Modbus, BACnet or EXOline) to operate as a stand-alone control or to be connected to a central system. Easy installation thanks to separate basic plate for cable connections. Display 5 different operating modes On/Off or V control Input for occupancy detector, window contact, condensation detector, CO2 sensor and change-over function Cooling and heating (water coil or electrical heater) EC fan control Setpoint buttons. STRA-07 for standard motor and STRA-17 for EC- fan CO2-control Occupancy (forced ventilation) Change-over 13 (18)

14 Application examples Room 2 Room 3 Room 4 SCADA EXOline alt. RS485 Modbus Transformer STRZ-24 (Required component) Fan speed relay STRZ-14 (Required component) Internal temperature sensor STRA-07 can control up to 8 fancoils 24V Optional accessories External temperature sensor STRZ-05 Occupancy detector STRZ-09 Changeover sensor STRZ (18) Condensation detector STRZ-16 Window contact STRZ-38

15 example in conference rooms, where many people are present at the same time for a certain period of time. Controller modes STRA-07/17 can be configured for different controller modes/control sequences: Heating Heating/Heating Heating/Cooling via change-over Heating/Cooling Heating/Cooling with VAV-control and forced supply air function Heating/Cooling with VAV-control Cooling Cooling/Cooling Heating/Cooling with change-over for cooling When Bypass has been activated by a press on the Occupancy button, the controller will automatically return to the preset operating mode (Occupied or Standby) after a configurable time (FS=2 hours). If an occupancy detector is used, the controller will automatically return to the preset operating mode after 10 minutes absence. description Occupancy detector The controller is factory set to Heating/cooling. Choosing another sequence is easily done in the parameter menu in the display. Information on how to access the parameter menu and configure the controller, consult either the technical manual or the installation and maintenance folder. Operating modes There are five different operating modes: Off, Unoccupied, Stand-by, Occupied and Bypass. Occupied is the preset operating mode. It can be changed to Standby in the parameter menu in the display. The operating modes can be activated via a central command, an occupancy detector or the Occupancy button. Off: Heating and cooling are disconnected. However, the temperature must not drop below the set minimum temperature (Factory setting (FS)=8 C). Operating mode Off is activated on open window. Unoccupied: The room where the controller is placed is not used for an extended period, for example during holidays or long weekends. Both heating and cooling are disconnected within a temperature interval with configurable min/max temperatures (FS min=15 C, max=30 C). Stand-by: The room is in an energy save mode and is not used at the moment. This can for example be during nights, weekends, evenings etc. The controller is prepared to change operating mode to Occupied if someone enters the room. Both heating and cooling are disconnected within a temperature interval around the applicable setpoint (FS heating setpoint value=-3 C, cooling setpoint=+3 C). Occupied: The room is in use and is therefore in a comfort mode. The controller regulates the temperature around a heating setpoint (FS=22 C) and a cooling setpoint (FS=24 C). Bypass: The temperature in the room is controlled in the same way as in operating mode Occupied. The output for forced ventilation is also active. Bypass is useful for 15 (18) By connecting an occupancy detector, STRZ-09 can switch between Bypass and the preset operating mode (Occupied or Stand-by). The temperature is then controlled according to requirement, which saves energy and keeps the temperature at a comfortable level. EC fan control for STRA-17 EC fan control is always activated in the STRA-17. The function can be activated in the control modes Heating, Heating/ Cooling via change-over, Heating/Cooling, Cooling and Cooling/Cooling. Control of electrical heater The function for a heating battery works in sequence with the change-over. The change-over function will then be used to switch between Summer and winter mode. In Summer mode, the STRA-07/17 will function as a Heating/Cooling controller while, in winter mode, it will function as a Heating/Heating controller. The electrical heating battery will start only if the water heating battery cannot meet the heating demand. It is important to note that the STRA-07/17 doesn t have inputs for fan running status and heater overheat. These functions must instead be provided by a supervisory system. Change-over function The STRA-07/17 has an input for change-over to operate with heating or cooling function. The input can be connected to sensors of type PT1000 and have the sensor mounted so that it senses the temperature on the supply pipe to the coil. As long as the heating valve is more than 20 % open, or every time a valve exercise is performed, the difference between the media and room temperature will be calculated. The control mode will change depending on the temperature difference. As an alternative, a potential-free contact can be used. When the contact is open, the controller works with the heating function and, when it is closed, with the cooling function. CO2 control In control modes where VAV (Variable Air Volume) is chosen, dampers outputs are affected by the CO2 level. On increasing CO2 level the damper opens to increase the quantity of air, regardless of the temperature requirements of the controller. The damper starts opening when the CO2 level exceeds CO2 level for starting

16 opening damper, and is fully opened at CO2 level for fully opened damper. Fan control STRA-07/17 has a fan button. The speed is set with the fan button. When the fan button is pressed, the fan speed will step from the current speed to the next. The controller has the following positions: Auto 0 I II III Automatic control of the fan speed to maintain desired room temperature Fan off Manual position with low speed Manual position with medium speed Manual position with high speed. In operating modes Off and Unoccupied, the fan is stopped, regardless of the setting in the display. 16 (18)

17 Description room controller STRA-07/17 Technical data Supply voltage Internal consumption Ambient temperature Storage temperature Ambient humidity Protection class Communication Modbus BACnet Communication speed Display Built-in temperature sensor Material Weight Colour V AC, Hz 2.5 VA 0-50 C C Max 90% RH IP20 RS485 (EXOline or Modbus with automatic detection/change-over, or BACnet) MS/TP slave and master 8 bits, 1 or 2 stop bits. Odd, even (FS) or no parity. 9600, 19200, bps (EXOline Modbus and BACnet) or bps (BACnet only) LCD with background illumination NTC type, measuring range 0-50 C, accuracy +/-0.5 C at C casing Polycarbonate, PC 110 g Cover: Polar white RAL9010 Bottom plate: Light gray This product conforms with the requirements of European EMC standards CENELEC EN and EN , and the requirements of European LVD standard IEC It carries the CE mark. Inputs External room sensor Change-over alt. potential-free contact Occupancy detector Condensation detector alt. window contact. PT1000-sensor, 0 50 C. Suitable sensors is STRZ-05 PT1000-sensor, C. Suitable sensor is STRZ-15 Closing potential-free contact. Suitable detector is STRZ-09 condensation detector STRZ-16 alt. Window contact STRZ-38 resp. potential-free contact Outputs Valve alt. thermal actuator Valve actuator Thermal actuator On/Off actuator STRA-17 (UO3) STRA-07 DO 2 outputs 0 10 V, max 5 ma 24 V AC, max 2.0 A (time-proportional pulse output signal) 24 V AC, Max. 2.0 A Control Heating, cooling or VAV (damper) EC fan V DC 1,2,3, for 3 fan speeds Setpoint settings via Regio tool or in the display Basic heating setpoint Basic cooling setpoint Setpoint displacement C C ± C (FS = ±3 C) Dimensions 17 (18)

18 Product code Room controller STRA-aa Type (aa) 07 = STRA-07 (For standard motor) 17 = STRA-17 (For EC motor) Fan speed relay unit Power unit for QZAZ STRZ Type (b) 3 = for 3-speed fans Housing (c) 0 = IP00 QZAZ-04-bb Type (bb) 10 = 3 speed manual control 20 = 3 speed manual control with integrated thermostat 75 = Automatic speed control with integrated thermostat Built in room controller for EC motor for QZBF, QZBT and QZBM QZAZ-14-bb Type (bb) 75 = Automatic speed control with integrated thermostat Wall mounted room controller QZAZ-05-bb Execution (bb) 77 = Supplied loose 78 = Factory mounted Electric board for QZAZ with QZB, QZSR, QZCC State of delivery (d) 0 = Supplied as loose accessory Built in Room Controller for standard motor for QZBF, QZBT and QZBM Type (bb) bb=16 Receiving board for QZHR and QFDK bb=18 Receiving board for QZSR, QZCC and QZB bb=19 Receiving board for QZHW NOTE One receiving board per fan coil for master slave control QZAZ-12-bb Execution (bb) 22 = Factory mounted for standard motor 23 = Supplied loose for standard motor 24 = Factory mounted for EC motor 25 = Supplied loose for EC motor NOTE Electric board is included in QFDK-aa-1/2-b-c-d and QZHW-aa-2-d-e Temperature sensors QZAZ-01-bb Type (bb) bb=30 Low temperature cut-out for bb=31 Change over sensor bb=32 Low temperature cut-out and change over sensor (for QZAZ and electronic board) QZAZ-05-bb Type (bb) 11 = 3 speed manual control for standard motor 21 = 3 speed manual control with integrated thermostat for standard motor 76 = Automatic speed control with integrated thermostat for standard & EC motor 95 = Automatic speed control with integrated thermostat for standard & EC motor with Modbus communication IR control QZAZ-05-bb Type (bb) 90 = IR remote control 91 = IR reciever factory mounted (QZBF/M/T) 92 = IR reciever, supplied loose (QZBA, QZSR, QZCC, QFDK with QFDZ-10) 94 = IR reciever, supplied loose (QFDK with QFDZ = IR reciever, supplied loose (QZHW) Speed switch for master slave with QZAZ QZAZ-12-bb 18 (18)

On/off room thermostats range. On/off V30 range. Master/slave PI V200 range. V3000 KNX networked PID range

On/off room thermostats range. On/off V30 range. Master/slave PI V200 range. V3000 KNX networked PID range Electromechanical controls Air control Water control On/off room thermostats range On/off room thermostats range Electronic controls Air control On/off V30 range On/off V30 range Water control Master/slave

More information

T5000 T000 LCD Digital Fan Coil Thermostat

T5000 T000 LCD Digital Fan Coil Thermostat T5000 T000 LCD Digital Fan Coil Thermostat T000 LCD Digital Fan Coil Thermostat T000 LCD Digital Fan Coil Thermostats are designed to control heating, cooling, or year round air conditioning unit in Commercial,

More information

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems 3 072 RDJ10RF RCR10/433 Wireless room temperature controller with 24-hour time switch and LCD Programmable, for heating systems RDJ10RF/SET Operating modes: Automatic, Comfort, Energy Saving, and Frost

More information

Electronic Control Devices The European Product Catalogue 2007

Electronic Control Devices The European Product Catalogue 2007 FX07 Field Controller (1/4) FX07 Field Controller Display Model Dimensions in mm (inches) The FX07 is a terminal unit controller in the Facility Explorer range of products. The controller is designed specifically

More information

Product catalog UNT-PRC011-E4

Product catalog UNT-PRC011-E4 Product catalog 4-way fan coil cassettes with AC fan motor technology - model CWS sizes 00-06 4-way fan coil cassettes with EC fan motor technology - model CWE sizes 01-05 Contents Introduction 4 Main

More information

Flush-mounted room thermostats

Flush-mounted room thermostats s 3 076 RDF300, RDF300.02, RDF340 RDF400.01 RDF600 RDF600 Flush-mounted room thermostats for 2-pipe, 2-pipe with el. heater and 4-pipe fan coil units for use with compressors in DX type equipment RDF300

More information

OPERATING INSTRUCTIONS (TRANSLATION OF THE ORIGINAL) SUPPLEMENTARY OPERATING INSTRUCTIONS FOR YOUR AIR CURTAIN SYSTEM. Serial number: Year: --- Page 1

OPERATING INSTRUCTIONS (TRANSLATION OF THE ORIGINAL) SUPPLEMENTARY OPERATING INSTRUCTIONS FOR YOUR AIR CURTAIN SYSTEM. Serial number: Year: --- Page 1 --- OPERATING INSTRUCTIONS (TRANSLATION OF THE ORIGINAL) SUPPLEMENTARY OPERATING INSTRUCTIONS FOR YOUR AIR CURTAIN SYSTEM Serial number: Year: Please quote this number when contacting customer service!

More information

Inwall Room Temperature Unit

Inwall Room Temperature Unit Inwall Room Temperature Unit TM11B01KNX TM11B11KNX TM11B21KNX Product Handbook Product: Inwall Room Temperature Unit Order Code: TM11B01KNX TM11B11KNX TM11B21KNX Application Program ETS: TM11B_1KNX Inwall

More information

DC1100 & 1400 Energy Controllers. Satchwell DC1100 & DC1400 for energy-efficient temperature control in smaller buildings.

DC1100 & 1400 Energy Controllers. Satchwell DC1100 & DC1400 for energy-efficient temperature control in smaller buildings. 1100 & 1400 Energy Controllers Satchwell 1100 & 1400 for energy-efficient temperature control in smaller buildings. 02 1100 & 1400 Energy Controllers Features he 1100 and 1400 Energy Controllers are self-configuring

More information

FX07 Field Controller

FX07 Field Controller Product Bulletin FX07 Field Controller Issue Date March 25, 2008 FX07 Field Controller The FX07 is a high performance field controller designed specifically for commercial Heating, Ventilating, Air Conditioning,

More information

Product catalog UNT-PRC017-E4

Product catalog UNT-PRC017-E4 Product catalog One-way fan coil cassettes with AC fan motor technology - model CFAS One-way fan coil cassettes with EC fan motor technology - model CFAE Sizes 16-26-36 UNT-PRC017-E4 Contents Introduction

More information

Electronic Control Devices The European Product Catalogue 2007

Electronic Control Devices The European Product Catalogue 2007 FX14 Field Controller (1/4) FX14 Field Controller The FX14 is an equipment field controller in the Facility Explorer range of products. The controller is designed specifically for commercial Heating, Ventilating,

More information

ABB i-bus KNX Fan Coil Controller FC/S 1.1

ABB i-bus KNX Fan Coil Controller FC/S 1.1 Product manual ABB i-bus KNX Fan Coil Controller FC/S 1.1 Intelligent Installation Systems Contents Page 1 Introduction... 2 2 Device technology... 3 3 Application and planning 3.1 Heating, ventilation

More information

RRV934. Multi-controller. Synco living

RRV934. Multi-controller. Synco living s 2 709 Synco living Multi-controller RRV934 RF-based multi-controller For precontrol of up to 2 room groups For control of ventilation plant with up to 3 stages RF communication based on KNX standard

More information

Semi flush-mount room thermostat with KNX communications For VAV heating and cooling systems

Semi flush-mount room thermostat with KNX communications For VAV heating and cooling systems s 3 72 Semi flush-mount room thermostat with KNX communications For VAV heating and cooling systems RDU34 KNX bus communications (S-mode and LTE mode) Backlit display PI / P control Outputs for DC 0 0

More information

S & P COIL PRODUCTS LTD SPC HOUSE, EVINGTON VALLEY ROAD, LEICESTER. LE5 5LU. Electrical layouts for EC Motors in Fan Convector units

S & P COIL PRODUCTS LTD SPC HOUSE, EVINGTON VALLEY ROAD, LEICESTER. LE5 5LU. Electrical layouts for EC Motors in Fan Convector units S & P COI PRODUCTS TD SPC HOUSE, EVIGTO VAEY ROAD, EICESTER. E5 5U Guidance Document Electrical layouts for EC Motors in Fan Convector units Hasnain Merchant Richard Meskimmon 4/9/0 This document is intended

More information

UNIFIED FACILITIES GUIDE SPECIFICATIONS

UNIFIED FACILITIES GUIDE SPECIFICATIONS USACE / NAVFAC / AFCEC / NASA UFGS-23 09 93 (November 2015) ----------------------------- Preparing Activity: USACE Superseding UFGS-23 09 23 (May 2011) UNIFIED FACILITIES GUIDE SPECIFICATIONS References

More information

HERZ-Thermal Actuators

HERZ-Thermal Actuators HERZ-Thermal Actuators Data Sheet 7708-7990, Issue 1011 Dimensions in mm 1 7710 00 1 7710 01 1 7711 18 1 7710 80 1 7710 81 1 7711 80 1 7711 81 1 7990 00 1 7980 00 1 7708 11 1 7708 10 1 7708 23 1 7709 01

More information

Vroom Hardware manual ver. 1.00 Code 114VROOHWE00. Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR

Vroom Hardware manual ver. 1.00 Code 114VROOHWE00. Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR ENGLISH HARDWARE MANUAL ver. 1.00 CODE 114VROOHWE00 page 1 of 22 Important Important Read these instructions

More information

PRODUCT PRODUCT CODE TECHNICAL INSTRUCTIONS PAGE

PRODUCT PRODUCT CODE TECHNICAL INSTRUCTIONS PAGE Table of Contents PRODUCT PRODUCT CODE TECHNICAL INSTRUCTIONS PAGE # Electric Room Comfort Controller NEW! RDY2000 Room Comfort Controller RDY 129-905 D-3 Electric for Specialized Applications Surface

More information

HVAC Processes. Lecture 7

HVAC Processes. Lecture 7 HVAC Processes Lecture 7 Targets of Lecture General understanding about HVAC systems: Typical HVAC processes Air handling units, fan coil units, exhaust fans Typical plumbing systems Transfer pumps, sump

More information

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw 4 937 DESIO Current valve for AC 24 V pulse/pause control of electrical loads up to 30 kw SEA45.1 Use The current valve is used for the control of electric heating elements in heating, ventilation and

More information

Room Controllers. SER8300 Line Voltage Fan Coil Room Controller with SC3000 Relay Pack

Room Controllers. SER8300 Line Voltage Fan Coil Room Controller with SC3000 Relay Pack Compatible with SmartStruxure solution SmartStruxure Lite solution Room Controllers Line Voltage Fan Coil Room Controller with SC3000 Relay Pack Application specific controller with customizable covers

More information

OZW30. Central Unit SYNERGYR

OZW30. Central Unit SYNERGYR 2 841 SYNERGYR Central Unit OZW30 Collects billing data from the apartments. Generates an image of each apartment's heat consumption and makes it available for readout. Acts on room temperature control

More information

T7560A,B,C Digital Wall Module

T7560A,B,C Digital Wall Module T7560A,B,C Digital Wall Module HONEYWELL EXCEL 5000 OPEN SYSTEM BEFORE INSTALLATION All wiring must comply with local electrical codes and ordinances or as specified on installation wiring diagrams. Digital

More information

Energy Saving Tips. Adjust set point temperature up a few degrees... Window contact. Occupancy sensor. A Programmable Thermostat

Energy Saving Tips. Adjust set point temperature up a few degrees... Window contact. Occupancy sensor. A Programmable Thermostat Energy Saving Tips Nowadays when Energy costs are skyrocketing and the awareness to environmental issues is increasing, we all want to reduce energy consumption and have a greener lifestyle. Heating &

More information

TABLE 1: Wiring Terminals. Connect to... 1C 1H 2C 2H 1H1C 2H1C 2H2C 3H2C

TABLE 1: Wiring Terminals. Connect to... 1C 1H 2C 2H 1H1C 2H1C 2H2C 3H2C Installation TURN OFF POWER TO THE SYSTEM AT THE MAIN POWER PANEL TO AVOID ELECTRICAL SHOCK. Installation should be carried out by an electrician or a qualified technician. 1.1 Find a Location for the

More information

LG Air Conditioning Multi F(DX) Fault Codes Sheet. Multi Split Units

LG Air Conditioning Multi F(DX) Fault Codes Sheet. Multi Split Units Multi Split Units If there is a fault on any LG Multi unit, an Error mark is indicated on the display window of the indoor unit, wired-remote controller, and LED s of outdoor unit control board. A two

More information

CR24-.. Single room controllers

CR24-.. Single room controllers Product information CR4- CR4- Single room controllers Table of contents wwwbelimocom Overview of the system Overview of functions 3 Technical data sheets CR4-B1 / CR4-A1 Single room controllers CR4-B /

More information

MP-4000 Alarm List (Software version 2.4.3 or later)

MP-4000 Alarm List (Software version 2.4.3 or later) Service Bulletin SUBJECT: MP4000 Alarm s BULLETIN: C 100 DATE: June 19, 2013 ALARM LIST Where it is possible the alarm number is kept the same as for MP-3000. MP-3000 holds alarm number from 0 to 127.

More information

ELECTRIC CENTRAL HEATING FLOW BOILER

ELECTRIC CENTRAL HEATING FLOW BOILER ELECTRIC CENTRAL HEATING FLOW BOILER EKCO.T Used product can t be treated as general communal waste. Disassembled appliance has to be delivered to the collection point of electrical and electronic equipment

More information

RKE. Heat recovery unit. heat recovery unit RKE. from 200 to 6800 m 3 /h. General features

RKE. Heat recovery unit. heat recovery unit RKE. from 200 to 6800 m 3 /h. General features RKE Heat recovery unit from 200 to 6800 m 3 /h General features RKE heat recovery units are suitable for residential and commercial applications and offer a real energy saving in forced ventilation plants,

More information

English plain text messages with constant backlight that brightens during user interaction. On/Off, Floating, or Proportional 0 to 10 VDC Control

English plain text messages with constant backlight that brightens during user interaction. On/Off, Floating, or Proportional 0 to 10 VDC Control TEC26x6(H)-4 and TEC26x6H-4+PIR Series BACnet MS/TP Networked Thermostat Controllers with Dehumidification Capability, Fan Control, and Occupancy Sensing Capability Product Bulletin Code No. LIT-12011587

More information

Heating, air-conditioning, cooling

Heating, air-conditioning, cooling Series description Design High efficiency, single stage, low pressure, inline centrifugal pump Supplied with EC motor and electronic duty adaptation Available in glanded construction, mechanical shaft

More information

RZAHUC program version 1.1 Regulation for Reznor Air Handling Units

RZAHUC program version 1.1 Regulation for Reznor Air Handling Units INSTALLATION INSTRUCTIONS OPTION 1xxx 1104_1000_EN Comfort Regulation (Carel pco) Detailed instructions RZAHUC program version 1.1 Regulation for Reznor Air Handling Units INDEX 1. Introduction... 4 1.1.

More information

Variable Air Volume - VAV

Variable Air Volume - VAV Mode Enable Sensor Options Variable Air Volume - VAV The temperature of this sensor will determine if the unit is in heating, cooling or vent mode during occupied operation. The following options are available:

More information

Temperature & Humidity SMS Alert Controller

Temperature & Humidity SMS Alert Controller Temperature & Humidity Alert Controller METERS 3 simple steps starting the unit: Insert the SIM card Plug in the sensors connectors Connect the AC power cord. Specifications: AC 90~260V Auto Select Internal

More information

For UK only RXL39.1 and the applications package SP-03 are sold in the United Kingdom only.

For UK only RXL39.1 and the applications package SP-03 are sold in the United Kingdom only. s For UK only RX39.1 and the applications package SP-03 are sold in the United Kingdom only. 3 876 3876P01 RX Room controller Communicating controllers for fan-coil applications SP-03 RX39.1 The RX39.1

More information

RDG/RDF room thermostats

RDG/RDF room thermostats RDG/RDF room thermostats Application Guide Answers for infrastructure. Application overview 2-pipe el. heater or radiator 4-pipe with el. heater Chilled/ heated ceiling Chilled/heated ceiling with el.

More information

Failure code manual. content

Failure code manual. content Failure code manual content 一 wall split AC series 2 二 floor standing AC series. 4 三 portable AC series.. 5 四 dehumidifer 6 五 DC inverter single split series...7 六 DC inverter multi-split series 10 1 一

More information

NC-12 Modbus Application

NC-12 Modbus Application NC-12 Modbus Application NC-12 1 Table of Contents 1 Table of Contents... 2 2 Glossary... 3 SCADA...3 3 NC-12 Modbus in general... 3 4 Entire system... 4 4.1 PFC to PC connection alternatives...4 4.1.1

More information

FX07 Field Controller

FX07 Field Controller Product Bulletin FX07 Field Controller Issue Date May 5, 2011 FX07 Field Controller The FX07 is a high performance field controller designed specifically for commercial Heating, Ventilating, Air Conditioning,

More information

IntesisBox KNX Mitsubishi Heavy Industries AC

IntesisBox KNX Mitsubishi Heavy Industries AC IntesisBox KNX Mitsubishi Heavy Industries AC Gateway for integration of Mitsubishi Heavy Indsutries (MHI) Air Conditioners with KNX control systems. 1. Main Features Direct connection to KNX TP-1 (EIB)

More information

Unica for KNX system 226

Unica for KNX system 226 Unica for KNX system 6 P117504 Greater flexibility and comfort, better energy efficiency with KNX More and more electronic appliances are needed for modern comfortable homes that contain everything from

More information

Building Technologies

Building Technologies Building Technologies RXB room automation system System overview Contents Comfort and well-being in every room...5 Range overview...6 Coordinated room controllers...7 The room units: the key to individual

More information

TC02 Curtain heater controller

TC02 Curtain heater controller B U I L D I N G C O N F I D E N C E TC02 Curtain heater controller (Previously known as the mini-fcu) Operations & Maintenance manual TBControls 2011 CTENTS 1....DOCUMENT MANAGEMENT... 3 1.1. Change Control

More information

Designer. of control solutions NA O7.124A

Designer. of control solutions NA O7.124A u n i v e r s a l c o m f o r t Designer of control solutions NA O7.124A CONTROL ADAPTED TO THE ENTIRE RANGE V for Vision: Our range of CIAT controls features all the techniques used for air conditioning,

More information

KONRAD. Hybrid Fancoil Series

KONRAD. Hybrid Fancoil Series KONRAD Hybrid Fancoil Series Konrad is an innovative radiator which cools you down and warms you up. Indeed, it cools in summer and heats in winter; but it makes it with an incomparable quietness. Thanks

More information

Voltage Regulator SPAU 341 C. Product Guide

Voltage Regulator SPAU 341 C. Product Guide Issued: July 1998 Status: Updated Version: D/25.04.2006 Data subject to change without notice Features Comprehensive voltage regulation for power transformers with on-load tapchangers in distribution substations

More information

sip Sanyo Modbus Guide Technical Specification Pinouts, Cable Connections & Wiring Issue 2: February 2009 Synapsys Solutions Ltd, all rights reserved

sip Sanyo Modbus Guide Technical Specification Pinouts, Cable Connections & Wiring Issue 2: February 2009 Synapsys Solutions Ltd, all rights reserved Sanyo Section : Section : Section : Section : Section : sip Modbus Guide Configuration Modbus Table Technical Specification Pinouts, Cable Connections & Wiring Alarm Fault Codes Issue : February 009 Section

More information

Technote. Frese OPTIMA Compact actuators DN10-DN32. Application. Features thermic actuators. Features motoric actuators. Approval. www.frese.

Technote. Frese OPTIMA Compact actuators DN10-DN32. Application. Features thermic actuators. Features motoric actuators. Approval. www.frese. Page 1 of 6 Application Proportional 0-10V or 3-position modulating or On/ Off control of Frese OPTIMA Compact valves in heating, ventilating and air conditioning systems. The actuator can be mounted on

More information

Programmable Room Thermostat 7 Day (5-2 Day) Models: 22083 / 22087 Power Supply: Battery / Mains

Programmable Room Thermostat 7 Day (5-2 Day) Models: 22083 / 22087 Power Supply: Battery / Mains Drayton Programmable Room Thermostat 7 Day (5-2 Day) Models: 22083 / 22087 Power Supply: Battery / Mains Invensys Controls Europe Technical Helpline: +44 (0) 845 130 7722 www.draytoncontrols.co.uk Installation

More information

HVAC and Lighting Control Products for Open Building Automation Systems

HVAC and Lighting Control Products for Open Building Automation Systems HVAC and Lighting Control Products for Open Building Automation Systems Distech Controls offers an extensive line of feature-rich and cost effective controllers for building automation, covering HVAC

More information

Drayton Digistat +2RF/+3RF

Drayton Digistat +2RF/+3RF /+3RF Programmable Room Thermostat Wireless Model: RF700/22090 Model: RF701/22092 Power Supply: Battery - Thermostat Mains - Digistat SCR Invensys Controls Europe Customer Service Tel: 0845 130 5522 Customer

More information

is then retained absolutely without interruption.

is then retained absolutely without interruption. Page 1 of 11 DC UPS uninterruptible power supplies - DC UPS module 15 A Compact design, only 50 mm wide Absolutely interruption-free buffering of power failures through immediate electronic connection

More information

3466 Building Energy Management Training Systems

3466 Building Energy Management Training Systems 3466 Building Energy Management Training Systems LabVolt Series Datasheet Festo Didactic en 120 V - 60 Hz 06/2015 Table of Contents General Description 3 Courseware 3 Topic Coverage 4 List of Available

More information

Type: EASY719 DC RC Article No.: 274119. Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

Type: EASY719 DC RC Article No.: 274119. Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description Type: EASY719 DC RC Article.: 274119 Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC Description 12 digital inputs (4 inputs available as analog inputs) 6 relay outputs LCD display

More information

Thermostat with display

Thermostat with display H/LN4691-0 674 59-64170 Thermostat with display RA00118AA_I-01PC-13W39 www.homesystems-legrandgroup.com Thermostat with display Contents Thermostat with display 1 Introduction 4 1.1 Warnings and recommendations

More information

Thermostats. comfort at your command

Thermostats. comfort at your command comfort at your command Carrier has met temperature control needs worldwide with its thermostats. Carrier thermostats provide computer-like intelligence with extremely simple operation in an elegant package.

More information

Thermostatic Wiring Principles by Bob Scaringe Ph.D., P.E.

Thermostatic Wiring Principles by Bob Scaringe Ph.D., P.E. Thermostatic Wiring Principles by Bob Scaringe Ph.D., P.E. Basic Thermostat Types Many technicians have great difficulty understanding how to properly wire a thermostat or how to replace a thermostat with

More information

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate 1 919 1919P01 1919P03 QBM65/C, QBM75-1U/C Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate QBM751-1/C QBM65/C QBM75/C Highly accurate measurements with calibration

More information

R22. K Control. Indoor Unit. Nomenclature. Compatibility PL H 3 G K H B. Unit style Heat Pump Horse Power

R22. K Control. Indoor Unit. Nomenclature. Compatibility PL H 3 G K H B. Unit style Heat Pump Horse Power R22. K Control. Indoor Unit. Nomenclature. PL H 3 G K H B Compatibility Unit style Heat Pump Horse Power Control Boost Heaters R22. K Control. Outdoor Unit. Nomenclature. PU H 3 Y K A Compatibility Outdoor

More information

RVL470. Heating Controller. Building Technologies HVAC Products. Series B

RVL470. Heating Controller. Building Technologies HVAC Products. Series B 2 522 Heating Controller Series B RVL470 Multifunctional heating controller for use in residential and non-residential buildings; suitable for weather-dependent flow temperature control of heating zones

More information

Programmable Thermostat MODEL 3312026.XXX With Dehumidify 3312024.XXX With Out Dehumidify

Programmable Thermostat MODEL 3312026.XXX With Dehumidify 3312024.XXX With Out Dehumidify Comfort Control Center 2 Thermostat Operating Instructions Programmable Thermostat MODEL 3312026.XXX With Dehumidify 3312024.XXX With Out Dehumidify TABLE OF CONTENTS About your new thermostat Features...2

More information

Lesson 36 Selection Of Air Conditioning Systems

Lesson 36 Selection Of Air Conditioning Systems Lesson 36 Selection Of Air Conditioning Systems Version 1 ME, IIT Kharagpur 1 The specific objectives of this chapter are to: 1. Introduction to thermal distribution systems and their functions (Section

More information

RF 1. Contents: Connecting diagram. Detailed information:

RF 1. Contents: Connecting diagram. Detailed information: Contents: Introduction UFH-ZONE-R UFH-EXTRAZONE -R Connection of a thermostat (UFH-THERM-R) o Joining of a thermostat with UFH-ZONE-R or UFH-EXTRAZONE-R Connection of a digital thermostat (UFH-THERM -RD)

More information

Cooling with CHW (fan coil Heating with LTHW radiator Modulating control of heating and cooling valve Automatic or manual fan control

Cooling with CHW (fan coil Heating with LTHW radiator Modulating control of heating and cooling valve Automatic or manual fan control Fan coil with two-pipe system (cooling) and radiators FC8 Cooling with CHW (fan coil Heating with HW radiator odulating control of heating and cooling valve Automatic or manual fan control Plant diagram

More information

B.IQ push button 3-5gang with room thermostat and display V2, flush-mounted 7566359x, 7566459x, 7566559x

B.IQ push button 3-5gang with room thermostat and display V2, flush-mounted 7566359x, 7566459x, 7566559x B.IQ push button 3-5gang with room Product name: Design: ETS search path: B.IQ push button 3-, 4-, 5gang with room thermostat and display V2 Flush-mounted Push button / B.IQ / B.IQ push button xgang with

More information

Duct Humidity Transmitter

Duct Humidity Transmitter SDC-H Duct Humidity Transmitter Features Replaceable sensor element Humidity measurement for air ducts Minimum and maximum value memory 0 0V, 0 0mA or 0V, 4 0mA measuring signals selectable with jumpers

More information

Table of Contents. 1 - Specifications...3. 2 - Installation...3. 3 - Wiring...5. 4 - User controls...7

Table of Contents. 1 - Specifications...3. 2 - Installation...3. 3 - Wiring...5. 4 - User controls...7 THERMOSTATS Table of Contents Page 1 - Specifications...3 1.1 - Product range...3 ARTTH001 (DSL-610)...3 ARTTH002 (DSL-700)...3 ARTTH003 (DSL-600)...3 1.2 - Technical data...3 1.3 - Power failures...3

More information

Belimo Gateway MP to Modbus RTU - UK24MOD

Belimo Gateway MP to Modbus RTU - UK24MOD Product information UK24MOD MODBUS RTU Belimo Gateway MP to Modbus RTU - UK24MOD Contents Complete overview 2 Technical data 3 Safety notes 4 Product features 4 Installation and commissioning 4 Electrical

More information

SMS GSM Alarm Messenger

SMS GSM Alarm Messenger SMS GSM Alarm Messenger Data Logging Alarm Input Relay Output Voice Temperature Humidity Analog Input Capture and Send Data via SMS Report triggered alarm via SMS Output triggered via SMS Auto pick up

More information

Workshop 7 PC Software - Tracker

Workshop 7 PC Software - Tracker Workshop 7 PC Software - Tracker Goal: You will startup and perform advanced setup functions using Tracker PC software. You will also setup equations to control MP503 binary outputs. The Binary Output

More information

IntesisBox KNX Modbus RTU master

IntesisBox KNX Modbus RTU master IntesisBox KNX RTU master Gateway for integration of RTU devices into KNX control systems. Integrate RTU devices (Chillers, Roof Tops, electricity meters, heating floors, heat pumps, PLCs ) into KNX control

More information

Heating / Ventilation / Air Conditioning Room Climate Control with ABB i-bus KNX

Heating / Ventilation / Air Conditioning Room Climate Control with ABB i-bus KNX Heating / Ventilation / Air Conditioning Room Climate Control with ABB i-bus KNX Content Heating / Ventilation / Air Conditioning 3 The Right Room Climate 4 Optimised Energy Efficiency and well-being Room

More information

FIREDEX 2200. Conventional Fire Panels

FIREDEX 2200. Conventional Fire Panels 68 Flexible, high specification system Choice of 1, 2, 4 or 8 zones Simple one-shot auto-reset user test facility Approved to EN54 Maintenance free poly switch circuit protection, with auto reset Class

More information

EBDSPIR-PRM, EBDSPIR-PRM-IP

EBDSPIR-PRM, EBDSPIR-PRM-IP Product Guide EBDSPIR-PRM, EBDSPIR-PRM-IP Ceiling PIR presence/absence detector Overview The EBDSPIR-PRM PIR (passive infrared) presence detector provides automatic control of lighting loads with optional

More information

HP 5 Microprocessor Control for Mammoth Water Source Heat Pumps

HP 5 Microprocessor Control for Mammoth Water Source Heat Pumps HP 5 Microprocessor Control for Mammoth Water Source Heat Pumps Operation and Maintenance Manual Model: 71028004 Applies to: Single Circuit Water-to-Water Twin Circuit Units Without DDC Controls MAMM WHSP

More information

Quick Connect. quick - simple - efficient. www.g-mw.de

Quick Connect. quick - simple - efficient. www.g-mw.de Quick Connect quick - simple - efficient www.g-mw.de Phone: +49 9103 7129-0 Fax: +49 9103 7129-207 Innovative connection technology to plug three single-phase current transformers to multifunctional power

More information

PolyGard Carbon Monoxide CO Transmitter ADTX3 1110

PolyGard Carbon Monoxide CO Transmitter ADTX3 1110 PolyGard Carbon Monoxide CO Transmitter ADTX3 1110 DESCRIPTION CO transmitter including digital measurement value processing and temperature compensation for the continuous monitoring of the ambient air

More information

IntesisBox Modbus Server SAMSUNG Air Conditioners

IntesisBox Modbus Server SAMSUNG Air Conditioners IntesisBox Modbus Server SAMSUNG Air Conditioners Gateway for monitoring and control of Samsung NASA compatible Air Conditioning Systems from any Modbus master device TCP or RTU (BMS, PLC, SCADA, HMI,

More information

CE6500 Energy Recovery Ventilator

CE6500 Energy Recovery Ventilator ADVANCED COMMERCIAL Energy Recovery Ventilator PRODUCT SPECIFICATIONS & TECHNICAL DATA Features NOMINAL CAPACITY 5500-7000 CFM CASING Double-wall cabinet White exterior paint, -gauge galvanized steel -gauge

More information

IntesisBox KNX LG Air Conditioning

IntesisBox KNX LG Air Conditioning IntesisBox KNX LG Air Conditioning Gateway for integration of LG Air Conditioners with KNX control systems. 1. Main Features Direct connection to KNX TP-1 (EIB) bus. Direct connection to LG outdoor unit

More information

B/S/H/ Error codes and service programmes PH

B/S/H/ Error codes and service programmes PH 1 ERROR CODES AND APPLIANCE MESSAGES... 3 1.1 Complete overview of all error codes (in order)... 3 Automatic switch-off... 3 Display is dark and any individual LEDs are lit... 3 E 005... 3 E 011... 3 E

More information

User Manual. Air-conditioner Controller SB-DN-HVAC (MAC01.331) www.hdlautomation.com

User Manual. Air-conditioner Controller SB-DN-HVAC (MAC01.331) www.hdlautomation.com Air-conditioner Controller SB-DN-HVAC (MAC01.331) www.hdlautomation.com Document updates: Version Data Description V1.0 2015.05.25 Finish new document HVAC Controller User Manual INDEX 1. Overview...1

More information

T-100-R Installation Guide

T-100-R Installation Guide T-100-R Installation Guide Table of Contents Page 2 Overview T-100-R Z-Wave Thermostat 3-4 Installation HVAC System Setup 6 Installer Settings Menu Items 7-9 Installer Settings Summary 10-11 Wiring Standard

More information

The ABB i-bus KNX Room Master Concept Your first step into the KNX world

The ABB i-bus KNX Room Master Concept Your first step into the KNX world The ABB i-bus KNX Room Master Concept Your first step into the KNX world The Room Master Concept 1 New Step 1,000 New Options You specialize in installing electrical systems. With the ABB Room Master,

More information

Data sheet ECC 12 and 22

Data sheet ECC 12 and 22 Application ECC is an electronic room temperature controller for water-based systems. ECC can control - fan-coil units - inductions units - air conditioning systems - small ventilating systems - 2-pipe

More information

Brochure 2012-2013.EX

Brochure 2012-2013.EX CLIMA CANAL Brochure 2012-2013.EX CLIMA CANAL Complete climate control and high power Heating, cooling, ventilation. Despite it s modest size, clima canal is a powerful heating, cooling and ventilation

More information

Application Sheet Fan coil unit with staged fan, heating/cooling coil (2 pipe) on analog output

Application Sheet Fan coil unit with staged fan, heating/cooling coil (2 pipe) on analog output Heating with LHW and cooling with CHW changeover Modulating control of heating and cooling valve (2 pipe) on analog Automatic or manual 3-speed fan control Room temperature and fan speed operation via

More information

ECL Comfort 110 Application 130. Weather compensated flow temperature control of heating and boiler systems. Instructions

ECL Comfort 110 Application 130. Weather compensated flow temperature control of heating and boiler systems. Instructions Instructions *087R9781* *VIKTG202* Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without

More information

REMOTE CONTROL MANUAL

REMOTE CONTROL MANUAL REMOTE CONTROL MANUAL ENGLISH CONTENT PRECAUTIONS...1-2 USING THE REMOTE CONTROL UNIT...3 OPERATION...4-9 Thank you for purchasing our Room Air Conditioner. Before using your air-conditioner, please read

More information

ABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG 110 084 R0011

ABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG 110 084 R0011 , 2CDG 110 084 R0011 2CDC 071 112 F0008 The Fan Coil Actuator is a modular installation device (MDRC) in pro M design. It is intended for installation in the distribution board on 35 mm mounting rails.

More information

Split Controller. User Manual SM-SS-F 2009/01/04

Split Controller. User Manual SM-SS-F 2009/01/04 Split Controller SM-SS-F User Manual 2009/01/04 Table of contents 1. Parts illustration.... 1 2. Electrical technical data...... 2 3. Electrical connection...3 4. Assemble parts...4 4.1 Assemble the fixed

More information

T6580 FAN COIL CONTROLLER

T6580 FAN COIL CONTROLLER T6580 FN COIL CONTROLLER PRODUCT SPECIFICTION SHEET DESCRIPTION pleasing and modern appearance makes the T6580 ideal for living quarter applications, in particular offices and hotels. In all versions,

More information

EKON BMS HVAC system. Simply Smart. www.ekonhome.com. Touch Screen Controller. Going green. Wireless. Wireless Thermostat with Light Switch

EKON BMS HVAC system. Simply Smart. www.ekonhome.com. Touch Screen Controller. Going green. Wireless. Wireless Thermostat with Light Switch Going green EKON BMS HVAC system Wireless Thermostat with Light Switch Control Fan Coil or Central AirCon Wireless Touch Screen Controller Wireless Light or Motorized Blind Wall Switch www.ekonhome.com

More information

Sterowniki uniwersalne z serii IR32. This is a universal step control for low cost solutions

Sterowniki uniwersalne z serii IR32. This is a universal step control for low cost solutions CAREL Sterowniki uniwersalne z serii IR32 This is a universal step control for low cost solutions Sterowniki uniwersalne z serii IR32 Mod.NTC Connection to temperature, humidity and pressure sensore (NTC,

More information

INSTALLER S & OWNER S MANUAL

INSTALLER S & OWNER S MANUAL INSTALLER S & OWNER S MANUAL HVAC INSTALLER: PLEASE LEAVE MANUAL FOR HOMEOWNER DEH 3000 DEH 3000 Part No. 4028539 Dehumidifier & Ventilation System Controller P.O. Box 8680 Madison, WI 53708 TOLL-FREE

More information

SEZ220. Signal Converter. Synco 200. With preprogrammed standard applications Freely programmable Menu-driven operation. Use

SEZ220. Signal Converter. Synco 200. With preprogrammed standard applications Freely programmable Menu-driven operation. Use s 5 146 Synco 200 Signal Converter SEZ220 With preprogrammed standard applications Freely programmable enu-driven operation Use The signal converter is for use in HVAC plant to provide minimum / maximum

More information

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs E031026 000823 Process modules Digital input PMI for inputs for 120 V AC inputs PMI Input E4, E5, GND L- PMI 120 V AC Input E4, E5, Common C E6, E7, GND L- E6, E7, Common C LEDs for the inputs operation

More information