CDR Room CO 2 and Temperature Sensor with BACnet

Size: px
Start display at page:

Download "CDR Room CO 2 and Temperature Sensor with BACnet"

Transcription

1 Product sheet SN1.405 Type CD-BAC CD-BAC oom CO 2 and Temperature Sensors with BACnet The CD-BAC sensors are designed to detect carbon dioxide concentration and temperature in the room spaces and have built-in BACnet MS/TP communication interface. The CO2 sensor calibrate automatically its measurement. The CD sensors have linear 0..10V signals outputs relating to CO2-concentration and other measurements. The sensors can be used for demand controlled ventilation in buildings. The CD-BAC sensors can be installed on a wall surface or on a wall mounting box in dry indoor environment. The CD sensors come with a number of options such as display, active setpoint, extra resistive/digital inputs, occupancy detection, lux level measurement and passive resistive sensor elements. The CD-BAC sensors have an additional resistive and a digital inputs for integrating local measurements such as window contacts or external temperature sensors. The CD-BAC sensors can also operate as CO2, Temperature, Light Level or Humidity controllers offering single enclosure measurement and control solutions. Other features include maximum demand control for ventilation plants. Model Type Model Description CD-BAC CD oom CO 2 and Temperature Sensor with BACnet MS/TP Communications, 1 DI, 1I, 3AO (0..10Vdc), 2 DO -LCD Display Option -H 2%rH elative Humidity Option -AL See Note 4 Alarm Display Option -SP See Note 3 Active Setpoint otary Knob Option -SPB See Note 5 Active Setpoint Push Button Option -LL See Note 1 Light Level and Occupancy Detection Option -PB Push Button Interface Option with Timer -PB2 2 Momentary Push Buttons with Timer -DI2 Digital Input Option for 2 Digital Inputs -I2 See Note 2 esistive Input Option for 2 esistive Inputs Accessories Model Description SW-DCT-USB Windows Device Configuration Tool Software with Serial USB Interface, 1.8m USB Lead Note 1: If -LL Option is selected the esistive Input 1 measurement is no longer available. Note 2: -I2 Option is not available if -SP option is selected. If both are required please contact SyxthSense for active setpoint options. Note 3. If -SP Option is selected the -LL options are no longer available (and vice versa). Note 4. If -LCD is fitted, the -AL option is provided with the backlight of the LCD. If -LCD is not fitted the alarm option is provided with the traffic light LEDs. Note 5. -SPB and -PB/PB2 options cannot be fitted at the same time. PS SN /21

2 Order Codes C D - BAC - LCD - SP e.g. CD-BAC-LCD-SP BACnet CO2 Transmitter with LCD, Setpoint Adjuster Optional Add On Optional Add On BACnet MS/TP Communication oom Space Installation Carbon Dioxide (Primary Measurement) Technical Data Power Supply Power supply 24Vac/dc -10%/+15%, max 1VA Displays and Interfaces Option -LCD LCD Display for Showing CO 2, Temperature, Humidity, Light Level (configurable through the tool or BACnet) Option -AL Green, Amber, ed Traffic Light LEDs (if -LCD not fitted) White, Amber, ed LCD Backlight with -LCD option (alarm limits 750 and 1250ppm, adjustable) Option -SP Setpoint Knob (network or control; adjustable min/max limits) Note: If this option is selected I2 Option (resistive input 2) is no longer available. Option -SPB Setpoint with 2 Push Buttons (network or control; adjustable min/max limits) Note: If this option is selected PB/PB2 options are no longer available. Please also select/order LCD option to visualise the setpoint. Option -PB Push Button with Delay Timer; status available through DO1, DO2 or via Network Option -PB2 2 x Push Buttons with Delay Timer; status available through DO1, DO2 or via Network Signal Outputs Analogue Outputs 3 x 0..10Vdc < 5mA; 100k min impedance for 1% accuracy Digital Outputs 2 x 24Vac 2A Triac; requires 24Vac Power Supply (DO1 & DO2) Option -PB (Push Button) DO1 or DO2 configurable as 24Vac Triac; requires 24Vac Power Supply Option -LL (Occupancy) DO1 or DO2 configurable as 24Vac Triac; requires 24Vac Power Supply Signal Inputs esistive Input 1 x NTC10/esistive Input, 0..50kOhms (network value) Digital Input 1 x Digital Input, Volt-Free Contact, Impedance <10KOhm Pulse Counting: Max 25Hz, Min Pulse Length 20mA (Volatile) Option -I2 Additional NTC10/esistive Input, in total 2 x NTC10/esistive Inputs, 0..50kOhms (network values) Option -DI2 Additional Digital Input, in total 2 x Digital Inputs, Volt-Free Contacts (network values), Impedance <10KOhm Pulse Counting: Max 25Hz, Min Pulse Length 20mA (Volatile) Sensing Characteristics Carbon Dioxide (CO 2 ) ange ppm CO 2 (ange Adjustable) Accuracy ± 50ppm + 3% of the 25 C (@77 F) Technology Auto Calibrating; Patented Non-Dispersive Infrared (NDI) Non-Linearity <1% FS Warm-Up Time <20 seconds esponse Time 2 minutes Temperature ange C ( F) Accuracy ±0.3 C Humidity; Option -H ange %rH Accuracy ±2% rh (within 0..90% rh) Light Level and Occupancy; Option -LL ange Occupancy Note: If this option is selected I1 (resistive input) is no longer available and need to be left disconnected. 0..3,000 Lux Infrared Detection (Adjustable Delay) PS SN /21

3 Communication BACnet Communications Protocol Interface MAC Addressing Communication BACnet MS/TP S485; maximum 63 devices via a bit switch; via tool / network 9k6/19k2/38k4/76k8 Baud; Parity /Even/Odd, 1 or 2 Stop Bits (baud rate adjustable through bit switch) Connections Terminal Connections Solid and Stranded Cable; 55 Angle for Wiring Maximum Size: 0.05 to 1.5mm 2 (EN ISO) / 14 to 30 AWG (UL) ising Clamp: Size 2.5 x 1.9mm Environmental Conditions Operating Storage Temperature Humidity Temperature Humidity 0 C C ( F) %rh (non-cond.) -30 C C ( F) %rh (non-cond.) Standards CE Conformity CE Directive 2004/108/EY EN : 2001 (Generic Emission) EN : 2001 (Generic Immunity). Degree of Protection IP20 Housing Housing Material ABS Plastics, Self Extinguishing, AL9010 Pure White Mounting Wall or Junction Box Mounting Dimensions W86 x H120 x D29mm Weight 180g Wiring Terminals 24 Vac elay 24 Vac elay 24 Vac/dc 0 V Network DO1 DO2 G Go Y1 Y2 Y3 Go Digital Output 1, 24Vac Digital Output 2, 24Vac 24 Vac/dc Supply Analogue 0..10Vdc, Configurable (CO2 default)* Analogue 0..10Vdc, Configurable (Temp as default)* Analogue 0..10Vdc, Configurable (%rh as default)* 0V Common BIT SWITCH ON A+ S485 (BACnet MS/TP) Network Address B- S485 (BACnet MS/TP) Go 0V Common I1 NTC10/esistive Input 1, 0..50kOhms DI1 Digital Input 1, Volt-Free I2 NTC10/esistive Input 2, 0..50kOhms (Option) DI2 End of Line Termination Comms TX Led 1 24 Digital Input 2, Volt-Free (Option) Bit ate 1 Bit ate 2 OFF CD-BAC CO2 Enable Links SETPOINT POTENTIOMETE Programming Interface %rh * Each of the outputs can be configured individually as for CO2, temperature, humidity, light level, control, maximum control or as a network value. USB to Transmitter Prog Cable (Option) USB DO1 Digital Output; 24Vac Triac Switching to 0V; max. 2A DO2 Digital Output; 24Vac Triac Switching to 0V; max. 2A G 24Vac/dc Power Supply G0 0V Common Y Vdc Analogue Output (Function Selectable) Y Vdc Analogue Output (Function Selectable) Y Vdc Analogue Output (Function Selectable) G0 0V Common A+ S485 A+ Connection (BACnet) B- S485 B- Connection (BACnet) PS SN /21

4 Digital Input Pulse Counting NTC10/esistive Inputs Y1/Y2/Y3 Analogue Output Operation (Modes) G0 I1 DI1 I2 DI2 Wiring Precautions 0V Common NTC10/esistive Input 0..50kOhms Digital Input; Volt-Free, Max 25Hz, Min Pulse Length 20mS NTC10/esistive Input 0..50kOhms Digital Input; Volt-Free, Max 25Hz, Min Pulse Length 20mS Switch off the power before any wiring is carried out. If the sensor has the LCD display fitted, unplug the LCD display and then wire the power supply and analogue outputs, if relevant. After the wiring has been completed; plug-in the display and power up the sensor. Digital Inputs can be used for pulse counting up to 25Hz, minimum pulse length 20mS. The pulse count is stored in a dedicated register and can be read over the network. It is possible to write to this register to reset the value. NOTE: The pulse count value is not battery backed, and therefore the network master is required to manage the data synchronisation in case of power failure. The resistive inputs can be configured to operate as NCT10 inputs or esistive Inputs. As default the inputs are configured as NTC10. The maximum measurement range is -10 C to 100 C (-40 F to 212 F). The configuration is changed via the Configuration Software. The analogue outputs Y1/Y2/Y3 can be configured for the following options. Output Modes Network CO 2 Measurement (Default for Y1) Temperature Measurement (Default for Y2) Humidity Measurement (requires -H option) Light Measurement (requires -LL option) CO 2 Control Temperature Control Humidity Control (requires -H) Light Control (requires -LL) Maximum Control Description The output is set by the network (BACnet). On the Modbus network the actual value is configured through "Y1, Y2, Y3 Override Values" parameters, respectively. The output represents the CO2 measurement.this this is scaled over 0..10V. The output represents the temperature measurement. This is scaled over 0..10V. The output represents the humidity measurement. This is scaled over 0..10V. The output represents the light level measurement. This is scaled over 0..10V. The output represents the CO2 control signal. The output represents the temperature control signal. The output represents the humidity control signal. The output represents the light level (LUX) control signal. The output represents the maximum of the CO 2 and temperature control signals. Typically used in ventilation plants where the ventilation level is boosted based on high CO 2 concentration or when high room temperature is prevailing (cooling). DO1/DO2 Digital Output Modes The DO1/DO2 digital outputs can be used to switch plants on/off based on a configured measurement and setpoint (thermostatic operation). If OC (Occupancy Sensor) option is fitted and then selected, the DO1/DO2 is used to switch output on when occupancy is detected. If the push button option (-PB) is fitted then DO1/DO2 can be set to switch ON when push button is pressed (delayed switch off). Digital Output Mode Options Network CO2 Control Mode (e.g. CO2 High Limit Control) Temperature Control Mode (e.g. Low Temperature Limit) Description (Typical Operation) The DO1/DO2 is switched ON/OFF over the communication network. Direct Mode: The DO1/DO2 is switched ON when the CO2 reading exceeds the CO2 Setpoint (1000 ppm default) + CO2 Digital Output Mode Hysteresis. The DO1/DO2 switches OFF when the CO2 reading drops below the setpoint.the control direction is adjustable; reverse / direct. everse Mode: The DO1/DO2 is switched ON when the temperature drops below the Temperature Setpoint - Temperature Mode Hysteresis. The output is switched OFF when the temperature exceeds the Setpoint. The control direction is adjustable; reverse (heating) / direct (cooling). PS SN /21

5 Digital Output Mode Options Humidity Control Mode (e.g. Humidity High Limit) (requires -H option) Light Level Control (LUX) Mode (e.g. Low Light Level) (requires -LL option) Occupancy (requires -LL option) Push Button (requires -PB option) Description (Typical Operation) Direct Mode: The DO1/DO2 is switched ON when the humidity reading exceeds the Humidity Setpoint (60% default) + Humidity Digital Output Mode Hysteresis, and switches OFF when the humidity drops below the Setpoint. The control direction is adjustable; reverse (humidification) / direct (de-humidification). everse Mode: The DO1/DO2 is switched ON when the light level drops below the Light Level Setpoint - Light Level Digital Output Mode Hysteresis, and switches OFF when the level increases above Setpoint. The control direction is adjustable. The DO1/DO2 is switched ON when the occupancy sensor detects occupancy; the output remains on adjustable time "Occupancy Delay Time Setting" plus approx 10 seconds after occupancy has been detected - not available on all models If -PB option is fitted, it is possible to have the DO1 (or DO2) on for the "Push Button Delay Time" specified in the settings after the pressing of button is detected. CO2 Measurement Output Scaling and Single Point Calibration CO2 Measurement Enable CO2 Measurement Auto-Calibration Temperature Measurement Output Scaling and Single Point Calibration The CD measures the carbon dioxide content of the room space and the measurement can be sent to any of the analogue outputs (Y1/Y2/Y3). It is also available over BACnet. This output is scaled as default 0% = 0ppm and 100% = 2,000ppm). The scaling can be modified through Maximum CO2 Scaling parameter. Furthermore the CO2 measurement reading can be adjusted on site using the Single Point Calibration field. 100% MEASUEMENT OUTPUT LOOP OUTPUT (Y1/Y2/Y3) Default Scaling 0% Scaling can be adjusted according to requirements. CO2 Scaling Max. Value CO2 Level CO2 measurement is enabled by inserting CO2 link jumpers (two) on the programming header. As default these are fitted (See programming interface section for further details). The CO2 sensor has automatic auto-calibration feature. This feature monitors the background CO2 level over the calibration period (8 days), and calibrates the CO2 level to the lowest point measured during this period. The sensors are supplied as factory calibrated to the typical background levels. After powering up the sensor, the sensor carries out initial calibration within 7 days after which the CO2 level is calibrated every 8 days automatically. If the CO2 sensor is fitted in spaces where the background level does not drop close to the typical background level of 400ppm (e.g. greenhouses) it is essential that the auto-calibration feature is disabled during the commissioning. The CD measures the room space temperature, and the measurement can be sent to any of the analogue outputs (Y1/Y2/Y3). It is also available over BACnet. This output is scaled as default 0% = 0 C and 100% = 50 C). The scaling can be modified through Maximum Temperature Scaling parameter. The output can also be scaled in Fahrenheit units. 100% MEASUEMENT OUTPUT LOOP OUTPUT 0% 0 25 Temperature Scaling Low Value Temperature C Default Scaling Scaling can be adjusted 50 according to requirements. Furthermore the temperature measurement reading can be adjusted on site using the Single Point Calibration field. + PS SN /21

6 Humidity Measurement Output Scaling and Single Point Calibration; Only when -H Option Fitted Light Level Measurement Output Scaling; Only when -LL Option Fitted CO2 Control Loop Operation Temperature Control Loop Operation The CD with -H option measures the room space humidity. The humidity reading is available over the network (BACnet version), and the measurement can be sent to any of the analogue outputs (Y1/Y2/Y3). This output is scaled as default 0% = 0 C and 100% = 100%rH). The scaling can be modified through Maximum Humidity Scaling parameter. 100% MEASUEMENT OUTPUT LOOP OUTPUT 0% 0 50 Furthermore the humidity measurement reading can be adjusted on site using the Single Point Calibration field. The CD sensors fitted with -LL option measure the light level. The light level (LUX) reading is available over the network (BACnet version), and the measurement can be sent to any of the analogue outputs (Y1/Y2/Y3). This output is scaled as default 0% = 0 LUX and 100% = 3,000 LUX). The scaling can be modified through Maximum LUX Scaling parameter. 100% MEASUEMENT OUTPUT LOOP OUTPUT LuxScaling Min. Value 0% 0 1,000 Scaling can be adjusted according to requirements. Humidity Scaling Low Value Default Scaling Humidity %rh + Scaling can be adjusted 100 according to requirements. Default Scaling Light Level Lux ENEGY SAVING FEATUE: When the LL option is combined with the SPB (Setpoint by buttons) option, it is possible to configure the control setpoint to automatically switch to setback/boost value when the room space is not occupied. Proportional or PI Control (everse/ Direct) The CO2 measurement can be used for the CO2 control. The calculated control 100% demand is then send to the output Y1, Y2 or Y3 (depending on the corresponding analogue output mode selection). The CO2 control loop output corresponds to the CO2 setpoint and the CO2 proportional band. If configured as Direct Control (typical), then if the CO2 level increases above the setpoint the loop output starts to modulate to 100%. When the CO2 level is the amount of the CONTOL OUTPUT LOOP OUTPUT (Y1, Y2, Y3) SP= Setpoint e.g. 800ppm PB = Proportional Band CO2 Control 2000 ppm 0% ppm PB SP CO2 Level e.g 400ppm Proportional Band above the setpoint the loop output is 100%. The configuration is done via the configuration parameters (or over the BACnet network). The CO2 control loop can also be configured to operate as Proportional + Integral control by changing the Integral Action Time from 0 to a required value. It is possible apply the Boost function to the control loop to override the output to 100% (see Boost Function for more details). Proportional or PI Control (everse/ Direct) The temperature measurement can also be used for the temperature control. The 100% calculated control demand is then send to the output Y1, Y2 or Y3 (depending on the corresponding analogue output mode selection). The temperature control loop output corresponds to the temperature setpoint and the temperature proportional band. If configured as everse Control (heating), then if the temperature level drops below the setpoint the loop output starts to CONTOL OUTPUT 0% - LOOP OUTPUT everse (Heating) Proportional Band SP SP= Setpoint Direct (Cooling) Temperature + modulate to 100%. When the temperature is the amount of the Proportional Band below the setpoint the loop output is 100%.In the Direct Control mode the output modulates in reverse. The configuration is done via the configuration parameters (or over the BACnet network). The temperature control loop can also be configured to operate as Proportional + Integral control by changing the Integral Action Time from 0 to a required value. It is possible apply the Boost function to the control loop to override the output to 100% (see Boost Function for more details). PS SN /21

7 Humidity Control Loop Operation Mode Selection; Only CD-H or when -H Option Fitted Light Level (LUX) Control Loop Operation; Only when -LL Option Fitted Maximum Control Loop Boost Function Digital Output DO1/DO2 Control Modes Proportional or Proportional + Integral Control (everse/ Direct) The humidity measurement can also be used for the humidity control. The calculated control demand is then send to the output Y1, Y2 or Y3 (depending on the corresponding analogue output mode selection).. The humidity control loop output corresponds to the humidity setpoint and the humidity proportional band. If configured as everse Control (humidification), then if the humidity level drops below the setpoint the loop output 100% CONTOL OUTPUT LOOP OUTPUT everse (Humidification) Direct (De-humidification) 100%rH 0% - Humidity %rh + 0%rH Proportional Band SP e.g 5%rH SP= Setpoint e.g. 50%rH starts to modulate to 100%. When the humidity is the amount of the Proportional Band below the setpoint the loop output is 100%.In the Direct Control mode the output modulates in reverse. The configuration is done via the configuration parameters (or over the BACnet network). The humidity control loop can also be configured to operate as Proportional + Integral control by changing the Integral Action Time from 0 to a required value. It is possible apply the Boost function to the control loop to override the output to 100% (see Boost Function for more details). Proportional Control (everse/ Direct) The LUX measurement can also be used for the light control. The calculated control demand is sent to the output Y1, Y2 or Y3 (depending on the corresponding analogue output mode selection). The light control loop output corresponds to the light level setpoint and the light control proportional band. If configured as everse Control, then if the light level drops below the setpoint the loop output starts to modulate to 100%. When the light level is the amount of the Proportional Band below 100% CONTOL OUTPUT LOOP OUTPUT Light Control (everse) SP= Setpoint e.g. 400 Lux PB = Proportional Band e.g 50 Lux Light Control (Direct) Light Level 0% Lux PB SP the setpoint the loop output is 100%.In the Direct Control mode the output modulates in reverse. The configuration is done via the configuration parameters (or over BACnet network). The LUX control loop can also be configured to operate as Proportional + Integral control by changing the Integral Action Time from 0 to a required value. It is possible apply the Boost function to the control loop to override the output to 100% (see Boost Function for more details). Each of the analogue outputs can also be configured as "Maximum Control". In this case the corresponding output (Y1, Y2, Y2) takes the maximum of the CO2 Loop and Temperature Loop outputs. This is typically used in demand based ventilation. It is possible to boost/override any of the control outputs to 100%. This can be achieved via a push button on the device (PB-option) or via a digital input. If the Push Button is used then the control output is boosted to 100% for the amount of Push Button Delay Time. When the boost is active the Blue Push Button backlight is lit. When the digital input the output is boosted to 100% when the input is closed. When the digital input is opened the output remains 100% for the time set in the parameter Digital Input Off Delay. The digital outputs DO1 or DO2 can be configured to work in any of the control modes; CO2 Control, Temperature Control; Humidity Control or LUX control; the corresponding digital output is switched ON/OFF based on the corresponding Setpoint property and the corresponding hysteresis. The direction of the operation is also adjustable through Control Loop Operating Mode Parameter. PS SN /21

8 The diagram below illustrates the operation for Temperature Control Mode. The same concept is applicable for any of the DO1/DO2 control modes (CO2, Temperature, Humidity, LUX). TEMPEATUE MEASUEMENT LOOP ON DIGITAL OUTPUT everse Mode Direct Mode DIGITAL OUTPUT DO1 MODE = TEMP DO1 DIGITAL OUTPUT (ON/OFF) OFF Temperature C + 0 Setpoint = 22 C Hysteresis = 1 C 22 1 C 1 C 50 Same selection is available for DO2. NOTE: Digital Output Control direction (direct/revers) is set by the Control Loop Operating Mode parameter. The switching points are defined by the Control Setpoints and Corresponding Hysteresis properties. Please note that Operating Mode and Setpoints are shared with the modulating control loop. Alarm LED / LCD Operation (CD-AL Models / Option) Setpoint Knob (-SP option) or Setpoint with Push Buttons (-SPB option) Display (equires Option -LCD) If the -AL option is fitted the transmitter is configured to monitor the CO 2, temperature, humidity or light levels for alarms. As standard the -AL option comes with traffic light LEDs. When -LCD option is also fitted the alarm condition is displayed using the backlight colours of the LCD instead of LEDs. (LCD replaces the LEDs). In both cases if the measurement exceeds the amber alarm limit then the amber LED / Backlight is switched ON. If the measurement exceeds the red alarm limit, the red LED / Backlight is switched ON. At normal condition green LED or white backlight is displayed. The alarm mode has an adjustable hysteresis to prevent the LEDs / Backlight flickering and all alarm limits are adjustable. The alarm condition is also available over the BACnet. The configuration is done via the configuration parameters (or over the BACnet). With setpoint options it is possible to adjust the current control setpoint. The setpoint knob option provides rotary knob for the setpoint whereas the SPB option provides two push buttons for setpoint. The adjustment shifts the CO2, temperature, humidity or LUX setpoint up or down depending on the configuration parameter settings. The setpoint can also be made 100% CONTOL OUTPUT 0% educe Setpoint SP= Setpoint Increase Setpoint Measurement - SP + only to be available as a network parameter (no influence to control). In this case the value displayed is between the minimum and the maximum settings (e.g -5.0 to +5.0). Note: SPB option requires also -LCD option to be selected/fitted. The LCD display shows the temperature, humidity, CO2 and LUX readings. CO2, temperature and LUX readings are primary readings displayed on the "top line". These readings can be rotated. The humidity reading is shown on the "bottom line" if -H option has been fitted. The display has white backlight which is as default switched off. The backlight can be switched on and its intensity can be adjusted. DISPLAY MODES CO2 PPM DISPLAY WITH HUMIDITY LUX DISPLAY TEMPEATUE DISPLAY WITH HUMIDITY (GEMAN) SETPOINT DISPLAY SETPOINT ADJ IS SHOWED WHEN KNOB IS OTATED (UNIT EFLECTS INFLUENCE PAAM). Note: The backlight is permanently on if activated. At 50% intensity the backlight lifetime is approx 10,000 hours. After this time the LCD module needs replacing if the backlight is required. The display continues to operate without the backlight. Configuration Parameters and Programming The parameter options can be configured using the SCT Sensor Configuration Tool software; or via the BACnet network using proprietary properties (see the BACnet parameter section). If the SCT Configuration software is used, this is connected via the PC USB cable (or via Bluetooth module) to the programming header of the transmitter. In order to connect please remove temporarily PS SN /21

9 the CO2 link jumpers (two), and store them securely to re-fit them after the programming is complete. Then plug-in the USB cable to the programming header as shown on the image below. Programming Header Connections USB / BLUETOOTH CABLE ENABLE CO2 MEASUEMENT POG CO2 LINK POG POG Programming Header ed White Green Black USB POGAMMING CABLE USB POGAMMING CABLE CONNECTO The correct process for connecting the sensor via the USB is as follows:- Disconnect USB Connector from PC Disconnect the Sensor from Power Plug-In the 4-Way Connector to the Sensor Connect the USB to the PC Power Up the Sensor NOTE: Always disconnect USB from PC before plugging the cable into the sensor. NOTE: The CO2 readings are not available unless the CO2 link jumpers are fitted. Common Parameters Parameter Name Defaults eset ead Write COM Port Description eloads the default configuration from the sensor non-volatile memory. Note: All modified settings are lost. Performs soft reset of the sensor. Apply after major changes. eads the sensor data. Writes the new settings to the sensor (automatically stored in the non-volatile memory) Select the COM port for the USB Cable or Bluetooth. USB cable driver must be installed in order the Serial to TTL connection to operate. PS SN /21

10 Live IO-View Parameter Name Description ange INPUTS CO2 Sensor CO2 Sensor eading 0..5,000ppm Temperature Sensor Temperature Sensor eading C ( F) Humidity Sensor Humidity Sensor eading % rh LUX Sensor LUX Sensor eading 0..3,000 LUX Setpoint Adjust Setpoint Adjuster eading esistive Input 1 esistive Input 1 eading 0..50kOhms esistive Input 2 esistive Input 2 eading 0..50kOhms Digital Input 1 Digital Input 1 Status Off - On Digital Input 2 Digital Input 2 Status Off - On Occupancy Occupancy Status Off - On Push Button Push Button Status Off - On Configuration Switch Bit Switch Status for Each Switch OUTPUTS Triac 1 Digital Output 1 Off - On Triac 2 Digital Output 2 Off - On Analogue Output 1 Analogue Output % Analogue Output 2 Analogue Output % Analogue Output 3 Analogue Output % Control Parameters Parameter Name Description ange TEMPEATUE Temperature Loop Operating Mode Direction of the temperature control loop. 0 = everse Control (Heating) 1 = Direct Control (Cooling) Temperature Control Setpoint Temperature Setpoint C/ F (Default 20 C) Temperature Proportional Band Temperature Proportional Band C/ F (Default 50 C) Temperature Control Integral Action Integral Action time of the temperature control loop ,000 seconds (Default 0s) Set to 0 to disable. Temperature Digital Output Mode Hysteresis Hysteresis for the digital output temperature control C/ F (Default 2 C) function. Temperature Loop Boost Input Boosts the Control Output to 100% Select Push Button 1/2 or Digital Input 1/2. HUMIDITY Humidity Loop Operating Mode Direction of the humidity control loop. 0 = everse Control (Humidification) 1 = Direct Control (De-humidification) Humidity Control Setpoint Humidity Setpoint %rh (Default 50%) Humidity Proportional Band Humidity Proportional Band %rh (Default 20.0%) Humidity Control Integral Action Integral Action time of the humidity control loop. Set 0..10,000 seconds (Default 0s) to 0 to disable. Humidity Digital Output Mode Hysteresis Hysteresis for the digital output humidity control function %rh (Default 5.0%) Humidity Loop Boost Input Boosts the Control Output to 100% Select Push Button 1/2 or Digital Input 1/2. CO2 CO2 Loop Operating Mode Direction of the CO2 control loop. 0 = everse Control 1 = Direct Control CO2 Control Setpoint CO2 Setpoint ppm (Default 1,000 ppm) CO2 Proportional Band CO2 Proportional Band ppm (Default = 300 ppm) CO2 Control Integral Action Integral Action time of the CO2 control loop. Set to ,000 seconds (Default 0s) to disable. CO2 Digital Output Mode Hysteresis Hysteresis for the digital output CO2 control ppm (Default 100 ppm) function. CO2 Loop Boost Input Boosts the Control Output to 100% Select Push Button 1/2 or Digital Input 1/2. PS SN /21

11 Control Parameters Parameter Name Description ange LUX Lux Loop Operating Mode Direction of the LUX control loop. 0 = everse Control 1 = Direct Control Lux Control Setpoint LUX Setpoint 0..3,000 Lux (Default 400 Lux) LUX Proportional Band LUX Proportional Band 1..3,000 Lux (Default 400 Lux) LUX Control Integral Action Integral Action time of the LUX control loop. Set to ,000 seconds (Default 0s) to disable. LUX Digital Output Mode Hysteresis Hysteresis for the digital output LUX control function. 1..3,000 Lux (Default 100 Lux) LUX Loop Boost Input Boosts the Control Output to 100% Select Push Button 1/2 or Digital Input 1/2. SETPOINT ADJUST Setpoint Adjuster Minimum Value Sets the minimum value for the setpoint (setpoint (Default -3.0) turned fully anti clockwise) Setpoint Adjuster Maximum Value Sets the maximum value for the setpoint (setpoint (Default 3.0) turned fully clockwise) Setpoint Value Influence to Control Setpoint Setpoint Value Influence to Control Setpoint 0 = No Influence (network value) 1 = CO2 Control 2 = Temperature 3 = Humidity 4 = Lux Inputs / Outputs Parameter Name Description ange SENSO INPUTS CO2 Offset One Point CO2 Calibration Field ppm (Default 0ppm) CO2 AO Scale Analogue Output Maximum CO2 Scaling ppm (Default = 2,000 ppm) Temperature Offset One Point Temperature Calibration Field C/ K (Default 0 C) Temperature AO Scale Analogue Output Maximum Temperature Scaling C/ F (Default 50 C) Humidity Offset One Point Humidity Calibration Field %rh (Default 0 %rh) Humidity AO Scale Analogue Output Humidity Maximum Scaling %rh (Default 100.0%) LUX AO Scale Analogue Output Maximum Lux Scaling ,000 Lux (Default 3,000 Lux) Occupancy Off Delay Delay Time Setting for Occupancy Seconds (Default 600) Push Button Off Delay Delay Time Setting for Push Button Seconds (Default 600) DI1 Off Delay Delay Time Setting for Digital Input Seconds (Default 0s) DI2 Off Delay Delay Time Setting for Digital Input Seconds (Default 0s) OUTPUTS AO1 (Y1) Analogue Output Y1 Mode 0 = Network Value 1 = CO2 Measurement (Default) 2 = Temperature Measurement 3 = Humidity Measurement 4 = Light Measurement (LUX) 5 = CO2 Control 6 = Temperature Control 7 = Humidity Control 8 = Light Control (LUX) 9 = Maximum Control PS SN /21

12 Inputs / Outputs Parameter Name Description ange AO2 (Y2) Analogue Output Y2 Mode 0 = Network Value 1 = CO2 Measurement (Default) 2 = Temperature Measurement 3 = Humidity Measurement 4 = Light Measurement (LUX) 5 = CO2 Control 6 = Temperature Control 7 = Humidity Control 8 = Light Control (LUX) 9 = Maximum Control AO3 (Y3) Analogue Output Y3 Mode 0 = Network Value 1 = CO2 Measurement (Default) 2 = Temperature Measurement 3 = Humidity Measurement 4 = Light Measurement (LUX) 5 = CO2 Control 6 = Temperature Control 7 = Humidity Control 8 = Light Control (LUX) 9 = Maximum Control DO1 Digital Output 1 Mode 0 = Network Value (Default) 1 = CO2 elay 2 = Temperature elay 3 = Humidity elay 4 = Light elay (LUX) 5 = Occupancy elay 6 = Push Button DO2 Digital Output 2 Mode 0 = Network Value (Default) 1 = CO2 elay 2 = Temperature elay 3 = Humidity elay 4 = Light elay (LUX) 5 = Occupancy elay 6 = Push Button Alarm/Display/Comms Parameter Name Description ange ALAMS Alarm Source Alarm LED Mode 0 = CO2 (default) 1 = Temperature 2 = Humidity 3 = LUX Alarm Amber Threshold Amber Alarm LED Switching Point (Default 750) Alarm ed Threshold ed Alarm LED Switching Point (Default 1250) Alarm Hysteresis Alarm LED Hysteresis (Default 50) DISPLAY Temperature Units Temperature Unit Selection 0 = Celsius 1 = Fahrenheit Language Language Selection (for display rh vs FH) 0 = English (default) 1 = German Display Mode Display Mode 0 = otate Installed 1 = CO2 Only 2 = Temperature Only 3 = LUX Only LCD brightness Brightness of the LCD Off - 10% to 100% COMMS BACnet Baud ate BACnet Baud ate (can only be set if B1 and B2 are in OFF position) 0 = 9600 (Default) 1 = = = BACnet Parity BACnet Parity 0 = (Default) 1 = Odd 2 = Even Stop Bits Stop Bits 0 = 1 Stop Bit (Default) 1 = 2 Stop Bits PS SN /21

13 Alarm/Display/Comms Parameter Name Description ange Address BACnet Address (can only be set if all address bit switches are in OFF position) (Default 1) Parameter Storage Setting Up BACnet Address and Baud ate The configuration parameters are stored in the non-volatile memory. The SCT (Sensor Configuration Tool) software will automatically store the register values on the non-volatile permanent memory after the changes are carried out. If the changes are carried out over the network (Modbus or BACnet), then "NonVol Update" flag is required to be forced on to save the changes. The parameter returns automatically to the off state once the values have been stored. The CD BACnet address and the baud rate is normally set through the bit switch. It is also possible to set the address and baud rate over the configuration tool or over the BACnet communication network. NOTE: The new settings are not activated until software reset or power down/up cycle has been applied. SETTING TANSMITTE BAUD ATE BAUD ATE BAUD ATE BIT SWITCH ON ON Network Address Bit ate 1 Bit ate 2 OFF BAUD ATE OFF ON ON OFF BAUD ATE 9600 / NETWOK ON SETTING TANSMITTE BACNET MAC ID The BACnet MAC ID is set by using bith switches BIT SWITCH 1 to 6 using binary decoding. Each bitswitch ON represents the binary value and the address is set by the combination of bit switches. Few examples: OFF Network Address Bit ate 1 Bit ate 2 BACNET MAC ID 2 ON BACNET MAC ID 9 ON OFF OFF Note: When the baud rate set 9600 via the bit switch it is possible to configure the baud rate via network / tool. Note: To activate the change the transmitter requires power cycle, or software reset via the tool OFF Note: If all address bit switches are set OFF, then the BACnet ID can be set over the BACnet or through configuration tool OFF BACnet Interoperability Building Blocks Supported (Annex K) Application Service Initiate Execute BIBB eadproperty Yes DS-P-B eadpropertymultiple Yes DS-PM-B WriteProperty Yes DS-WP-B einitializedevice Yes Who-Is Yes DM-DDB-B I-Am Yes Who-Has Yes DM-DOB-B I-Have Yes DeviceCommunicationControl Yes DM-DCC-B BACnet Standard Types Supported No dynamic Creation or Deletion supported. s, and object instances, are assigned to fixed functions within the proprietary control application of the product as follows: Number Of Instance Assignments Instances Device 1 Analog Input 7 AI(0) Temperature Sensor AI(1) Setpoint Adjust AI(2) Humidity Sensor AI(3) I1 AI(4) I2 AI(5) C02 Sensor AI(6) LUX Sensor Analog Outputs 3 AO(0) Y1 Output AO(1) Y2 Output AO(2) Y3 Output Analogue Value 7 AV(0) Temperature Setpoint AV(1) Humidity Setpoint AV(2) CO2 Setpoint AV(3) LUX Setpoint AV(4) DI1 Pulse Count AV(5) DI2 Pulse Count AV(6) - LCD Backlight Brightness PS SN /21

14 Number Of Instances Instance Assignments Binary Input 4 BI(0) DI1 input BI(1) DI2 Input BI(2) Occupancy BI(3) Push Button 1 Binary Output 2 BO(0) DO1 Output BO(1) DO2 Output MutliState Input 1 MSI(0) - Alarm Level Device (equired ) Property Name /ID Attributes ange Default Identifier /W MAC_Address Name /W 32 Characters Max Concatenation of product type and MAC address i.e. "CD_001" Type 8 System Status STATUS_OPEATIONAL Vendor Name SyxthSense Vendor Identifier 651 Model Name UD Protocol Version 1 Protocol evision 10 Max APDU Length 480 Segmentation Support No APDU Timeout 3000 ms Number APDu etries 3 MaxMaster 127 Max_Info_Frames 1 Database evision 0 PS SN /21

15 Analogue Input s equired Optional Proprietary Property Name /ID Attributes ange Default Identifier Name AI(0) Temperature Sensor AI(1) Setpoint Adjust AI(2) Humidity Sensor AI(3) I1 AI(4) I2 AI(5) C02 Sensor AI(6) LUX Sensor Type 0 Present Value /W AI(0): AI(1): AI(2): AI(3): AI(4): AI(5): AI(6): Status Flag Event State Out-Of-Service /W FALSE Units AI(0): UNITS_DEGEES_CELCIUS or UNITS_DEGEES_FAHENHEIT AI(1): UNITS_DEGEES_CELCIUS or UNITS_DEGEES_FAHENHEIT AI(2): UNITS_PECENT AI(3): UNITS_OHMS AI(4): UNITS_OHMS AI(5): UNITS_PATS_PE_MILLION AI(6): UNITS_LUXES Analogue Output s equired Optional Proprietary Property Name /ID Attributes ange Default Identifier Name AO(0) = Y1 AO(1) = Y2 AO(2) = Y3 Type 1 Present Value /W Status Flag Event State Out-Of-Service /W FALSE Units UNITS_PECENT : PS SN /21

16 Analogue Value s equired Optional Proprietary Property Name /ID Attributes ange Default Identifier Name AV(0) Temperature Setpoint AV(1) Humidity Setpoint AV(2) CO2 Setpoint AV(3) LUX Setpoint AV(4) - DI1 Pulse Count AV(5) - DI2 Pulse Count AV(6) - LCD Backlight Brightness Type 2 Present Value /W AV(0): AV(1): AV(2): AV(3): AV(4): AV(5): AV(6): Status Flag Event State Out-Of-Service /W FALSE Units AV(0) = UNITS_DEGEES_CELSIUS or UNITS_DEGEES_FAHENHEIT AV(1) = UNITS_PECENT AV(2) = UNITS_PATS_PE_MILLION AV(3) = UNITS_LUXES AV(4) = NO_UNITS AV(5) = NO_UNITS AV(6) = NO_UNITS Priority Array elinquish Default /W AV(0) = Nonvol Temperature Setpoint AV(1) = Nonvol HumiditySetpoint AV(2) = Nonvol CO2 Setpoint AV(3) = Nonvol LUX Setpoint AV(4) = 0 AV(5) = 0 AV(6) = 0 Binary Input s equired Optional Property Name /ID Attributes ange Default Identifier Name BI(0) = DI1 BI(1) = DI2 BI(2) = Occupancy BI(3) = Push Button Type 3 Present Value /W 0..1 Status Flags Event State Out-Of-Service /W FALSE Polarity /W POLAITY_NOMAL Active Text "on" Inactive Text "off" PS SN /21

17 Proprietary Property Name /ID Attributes ange Default Binary Output s equired Optional Proprietary Property Name /ID Attributes ange Default Identifier Name BO(0) = DO1 BO(1) = DO2 Type 4 Present Value /W 0..1 Status Flags Event State Out-Of-Service /W FALSE Polarity /W POLAITY_NOMAL Priority Array elinquish Default /W BINAY_INACTIVE Active Text "on" Inactive Text "off" Multi-State Input s equired Optional Proprietary Property Name /ID Attributes ange Default Identifier Name "Alarm Level" Type 13 Present Value /W 1,2,3 (Green, Amber, ed) Status Flags Event State Out-Of-Service /W FALSE Number-Of-States 3 Proprietary Types No dynamic Creation or Deletion supported Application Configuration Number Of Instances Instance Assignments 1 Provides a container for all the proprietary application specific properties. Proprietary Property Id's within the object have been deliberately chosen to correspond to the equivalent Modbus register addresses for this product. App_Config equired Property Name /ID Attributes ange Default Identifier MAC_Address Name "App_Config" Type 128 PS SN /21

18 Optional Property Name /ID Attributes ange Default Proprietary Property ID Description BACnet Data Type ange Firmware Version ead Only Analogue Output Y1 Mode Analogue Output Y2 Mode Analogue Output Y3 Mode 0 = Network Value 1 = CO2 Measurement (Default) 2 = Temperature Measurement 3 = Humidity Measurement 4 = Light Measurement 5 = CO2 Control 6 = Temperature Control 7 = Humidity Control 8 = Light Control 9 = Maximum Control 0 = Network Value 1 = CO2 Measurement 2 = Temperature Measurement (Default) 3 = Humidity Measurement 4 = Light Measurement 5 = CO2 Control 6 = Temperature Control 7 = Humidity Control 8 = Light Control 9 = Maximum Control 0 = Network Value 1 = CO2 Measurement 2 = Temperature Measurement 3 = Humidity Measurement (Default) 4 = Light Measurement 5 = CO2 Control 6 = Temperature Control 7 = Humidity Control 8 = Light Control 9 = Maximum Control AO4 Mode (eserved for future use) Digital Output 1 Mode Digital Output 2 Mode CO2 Control Setpoint CO2 Proportional Band CO2 Control Integral Action CO2 Loop Operating Mode 0 = Network Value (Default) 1 = CO2 elay 2 = Temperature elay 3 = Humidity elay 4 = Light elay 5 = Occupancy elay 6 = Push Button 0 = Network Value (Default) 1 = CO2 elay 2 = Temperature elay 3 = Humidity elay 4 = Light elay 5 = Occupancy elay 6 = Push Button ppm (Default 1,000 ppm) ppm (Default = 300 ppm) 0..10,000 seconds 0 = everse Control 1 = Direct Control PS SN /21

19 40014 CO2 Digital Output Mode Hysteresis Temperature Control Setpoint Temperature Proportional Band Temperature Control Integral Action Temperature Loop Operating Mode Temperature Digital Output Mode Hysteresis ppm (Default 100 ppm) C/ F (Default 20 C) C/ F (Default 50 C) 0..10,000 seconds 0 = everse Control (Heating) 1 = Direct Control (Cooling) C/ F (Default 2 C) Humidity Control Setpoint Humidity Proportional Band Humidity Control Integral Action Humidity Loop Operating Mode Humidity Digital Output Mode Hysteresis Lux Control Setpoint LUX Proportional Band LUX Control Integral Action Lux Loop Operating Mode LUX Digital Output Mode Hysteresis Amber Alarm LED Switching Point ed Alarm LED Switching Point Alarm LED Hysteresis Alarm LED Mode Delay Time Setting for Occupancy Delay Time Setting for Push Button Setpoint Adjuster / Potentiometer Low Position EAL EAL %rh (Default 50%) %rh (Default 20.0%) 0..10,000 seconds 0 = everse Control (Humidification) 1 = Direct Control (De-humidification) %rh (Default 5.0%) 0..3,000 Lux (Default 400 Lux) 1..3,000 Lux (Default 400 Lux) 0..10,000 seconds 0 = everse Control 1 = Direct Control 1..3,000 Lux (Default 100 Lux) (Default 750) (Default 1250) (Default 50) EAL 0 = CO2 (default) 1 = Temperature 2 = Humidity 3 = LUX Seconds Seconds (-3.0) Default PS SN /21

20 40037 Setpoint Adjuster / Potentiometer High Position Setpoint Value Influence to Control Setpoint Temperature Unit Selection Language Selection (for display rh vs FH) EAL (3.0) Default 0 = No Influence 1 = CO2 Control 2 = Temperature 3 = Humidity 4 = Lux 0 = Celsius 1 = Fahrenheit 0 = English (default) 1 = German Display Mode 0 = otate Installed 1 = CO2 Only 2 = Temperature Only 3 = LUX Only Analogue Output Maximum CO2 Scaling Analogue Output Maximum Temperature Scaling Analogue Output Humidity Maximum Scaling Analogue Output Maximum Lux Scaling One Point CO2 Calibration Field One Point Temperature Calibration Field One Point Humidity Calibration Field EAL EAL EAL ppm (Default = 2,000 ppm) C/ F (Default 50 C) %rh (Default 100.0%) ,000 Lux (Default 3,000 Lux) ppm (Default 0ppm) C/ K (Default 0 C) %rh (Default 0 %rh) MAC Address Baud ate 0 = 9600 (Default) 1 = = = Hold On Delay Setting for Digital Input Seconds Hold On Delay Setting for Digital Input Seconds Force eset 0 = Normal 1 = Force eset Non Volatile Memory Update Force Factory Defaults Force 0..10V Output Calibration outine 0 = Normal 1 = Update 0 = Normal 1 = Force Defaults 0 = Normal 1 = Force Calibration PS SN /21

21 40105 Force CO2 Sensor Calibration outine 0 = Normal 1 = Force Calibration Dimensions Wall Box Screw Hole Locations PS SN /21

PolyGard Carbon Monoxide CO Transmitter ADTX3 1110

PolyGard Carbon Monoxide CO Transmitter ADTX3 1110 PolyGard Carbon Monoxide CO Transmitter ADTX3 1110 DESCRIPTION CO transmitter including digital measurement value processing and temperature compensation for the continuous monitoring of the ambient air

More information

Inwall Room Temperature Unit

Inwall Room Temperature Unit Inwall Room Temperature Unit TM11B01KNX TM11B11KNX TM11B21KNX Product Handbook Product: Inwall Room Temperature Unit Order Code: TM11B01KNX TM11B11KNX TM11B21KNX Application Program ETS: TM11B_1KNX Inwall

More information

7.6.4 Communication via BACnet MS/TP. Logical error. Maximum processing time, p2024[0] Process data monitoring time (setpoint timeout), p2040

7.6.4 Communication via BACnet MS/TP. Logical error. Maximum processing time, p2024[0] Process data monitoring time (setpoint timeout), p2040 Logical error If the slave detects a logical error within a request, it responds to the master with an "exception response". In this case, the slave sets the highest bit in the function code to 1 in the

More information

Electronic Control Devices The European Product Catalogue 2007

Electronic Control Devices The European Product Catalogue 2007 FX14 Field Controller (1/4) FX14 Field Controller The FX14 is an equipment field controller in the Facility Explorer range of products. The controller is designed specifically for commercial Heating, Ventilating,

More information

FX07 Field Controller

FX07 Field Controller Product Bulletin FX07 Field Controller Issue Date March 25, 2008 FX07 Field Controller The FX07 is a high performance field controller designed specifically for commercial Heating, Ventilating, Air Conditioning,

More information

Ventostat Wall Mount. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. GE Measurement & Control. Features:

Ventostat Wall Mount. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. GE Measurement & Control. Features: GE Measurement & Control Ventostat Wall Mount Telaire Wall Mount, Humidity and Temperature Transmitters Features: Patented, Absorption Infrared Gas sensing engine provides high accuracy in a compact low

More information

Electronic Control Devices The European Product Catalogue 2007

Electronic Control Devices The European Product Catalogue 2007 FX07 Field Controller (1/4) FX07 Field Controller Display Model Dimensions in mm (inches) The FX07 is a terminal unit controller in the Facility Explorer range of products. The controller is designed specifically

More information

TAC I/NETTM MR-VAV-AX. Application Specific MicroRegulator TM

TAC I/NETTM MR-VAV-AX. Application Specific MicroRegulator TM TAC I/NETTM TM TAC s TM has an extensive range ofpre-engineered VAV control sequences, which combined with a fully integrated actuator and airflow transducer, makes it a low Total Installed Cost solution

More information

BACnet Protocol Implementation Conformance Statement

BACnet Protocol Implementation Conformance Statement BAnet Protocol Implementation onformance Statement Date: November 13, 2012 Vendor Name: ABB Inc Product Name: Low Voltage A Motor Drive Product Model Number: AS320 Applications Software Version: 403 Firmware

More information

IntesisBox Modbus Server SAMSUNG Air Conditioners

IntesisBox Modbus Server SAMSUNG Air Conditioners IntesisBox Modbus Server SAMSUNG Air Conditioners Gateway for monitoring and control of Samsung NASA compatible Air Conditioning Systems from any Modbus master device TCP or RTU (BMS, PLC, SCADA, HMI,

More information

Duct Humidity Transmitter

Duct Humidity Transmitter SDC-H Duct Humidity Transmitter Features Replaceable sensor element Humidity measurement for air ducts Minimum and maximum value memory 0 0V, 0 0mA or 0V, 4 0mA measuring signals selectable with jumpers

More information

FX07 Field Controller

FX07 Field Controller Product Bulletin FX07 Field Controller Issue Date May 5, 2011 FX07 Field Controller The FX07 is a high performance field controller designed specifically for commercial Heating, Ventilating, Air Conditioning,

More information

T5000 T000 LCD Digital Fan Coil Thermostat

T5000 T000 LCD Digital Fan Coil Thermostat T5000 T000 LCD Digital Fan Coil Thermostat T000 LCD Digital Fan Coil Thermostat T000 LCD Digital Fan Coil Thermostats are designed to control heating, cooling, or year round air conditioning unit in Commercial,

More information

Installing the Tracer ZN517 Unitary Controller Ordering number: 4950 0496, 4950 0596

Installing the Tracer ZN517 Unitary Controller Ordering number: 4950 0496, 4950 0596 Installing the Tracer ZN517 Unitary Controller Ordering number: 4950 0496, 4950 0596 Product overview The Tracer ZN517 controller is a field-installed, application-specific controller that provides directdigital

More information

T7560A,B,C Digital Wall Module

T7560A,B,C Digital Wall Module T7560A,B,C Digital Wall Module HONEYWELL EXCEL 5000 OPEN SYSTEM BEFORE INSTALLATION All wiring must comply with local electrical codes and ordinances or as specified on installation wiring diagrams. Digital

More information

HCS-3300/3302/3304 USB Remote Programmable Laboratory Grade Switching Mode Power Supply

HCS-3300/3302/3304 USB Remote Programmable Laboratory Grade Switching Mode Power Supply 1. INTRODUCTION HCS-3300/3302/3304 USB Remote Programmable Laboratory Grade Switching Mode Power Supply User Manual This family of efficient, upgraded SMPS with small form factor, auto cross over CV CC,

More information

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply) transmitter (2 wire) / switch for continuous or On/Off Control Indication, monitoring, transmitting and continuous or On/Off control in one device Output signal 4...20 ma, 2-wire for continuous control

More information

FLOW CALCULATOR INSTRUCTION MANUAL MESURES BAMOPHOX 759 26-06-2007 759 M1 02 E MES FLOW CALCULATOR 759-02/1

FLOW CALCULATOR INSTRUCTION MANUAL MESURES BAMOPHOX 759 26-06-2007 759 M1 02 E MES FLOW CALCULATOR 759-02/1 BAMOPHOX 759 E - M FLOW CALCULATOR INSTRUCTION MANUAL MESURES 22, Rue de la Voie des Bans - Z.I. de la Gare - 95100 ARGENTEUIL Tél : (33) 01 30 25 83 20 - Web : www.bamo.fr Fax : (33) 01 34 10 16 05 -

More information

KNX Panasonic Air Conditioners

KNX Panasonic Air Conditioners IntesisBox KNX Panasonic Air Conditioners Gateway for Panasonic ECOi and PACi system integration into KNX networks Up to 30 Outdoor units Up to 64 Indoor units PA-AC-KNX-64/128 EIA485 U1U2 line U1U2 line

More information

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

Automation System TROVIS 6400 TROVIS 6493 Compact Controller Automation System TROVIS 6400 TROVIS 6493 Compact Controller For panel mounting (front frame 48 x 96 mm/1.89 x 3.78 inch) Application Digital controller to automate industrial and process plants for general

More information

IntesisBox KNX LG Air Conditioning

IntesisBox KNX LG Air Conditioning IntesisBox KNX LG Air Conditioning Gateway for integration of LG Air Conditioners with KNX control systems. 1. Main Features Direct connection to KNX TP-1 (EIB) bus. Direct connection to LG outdoor unit

More information

Carbon Monoxide (CO) Gas Detection and Control System

Carbon Monoxide (CO) Gas Detection and Control System Carbon Monoxide (CO) Gas Detection and Control System Specifications subject to change without notice. USA 4094 Page of 6 DESCRIPTION Carbon monoxide (CO) detection and control system, wall-mounted, with

More information

HMI display Installation Guide

HMI display Installation Guide HMI display Installation Guide Product Description Specifications Important Information o Package Contents o Related Documents o Accessories Cautions and Warnings Mounting and Dimensions o BAC-DIS-ENC

More information

IntesisBox KNX Modbus RTU master

IntesisBox KNX Modbus RTU master IntesisBox KNX RTU master Gateway for integration of RTU devices into KNX control systems. Integrate RTU devices (Chillers, Roof Tops, electricity meters, heating floors, heat pumps, PLCs ) into KNX control

More information

TLK 48 MICROPROCESSOR-BASED DIGITAL ELECTRONIC REGULATOR

TLK 48 MICROPROCESSOR-BASED DIGITAL ELECTRONIC REGULATOR TLK 48 MICROPROCESSOR-BASED DIGITAL ELECTRONIC REGULATOR TECHNICAL DATA CARATTERISTICHE MECCANICHE Housing Self-extinguishing plastic, UL 94 V0 Dimensions 48x48 mm DIN depth 98 mm Weight 225 g approx.

More information

Application/Connection Examples

Application/Connection Examples This Quick Start Guide is designed to familiarize the user with the connection and configuration of the DTS-305 DIN rail mounted single / 3 phase power & energy meter with RS-485 or TCP communications.

More information

Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION

Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION Modular, Customizable Wire Replacement 128 / 256 Bit AES Encryption Software Selectable RF Transmit Power Software Selectable Over-the-air Data Rate Modbus ASCII /RTU Compatible Wide Operating Temperature

More information

T-100-R Installation Guide

T-100-R Installation Guide T-100-R Installation Guide Table of Contents Page 2 Overview T-100-R Z-Wave Thermostat 3-4 Installation HVAC System Setup 6 Installer Settings Menu Items 7-9 Installer Settings Summary 10-11 Wiring Standard

More information

ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL

ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL RANCO INSTALLATION INSTRUCTIONS ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL Relay Electrical Ratings PRODUCT DESCRIPTION The Ranco ETC is a microprocessor-based family of electronic temperature controls,

More information

Vroom Hardware manual ver. 1.00 Code 114VROOHWE00. Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR

Vroom Hardware manual ver. 1.00 Code 114VROOHWE00. Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR ENGLISH HARDWARE MANUAL ver. 1.00 CODE 114VROOHWE00 page 1 of 22 Important Important Read these instructions

More information

IntesisBox KNX Mitsubishi Heavy Industries AC

IntesisBox KNX Mitsubishi Heavy Industries AC IntesisBox KNX Mitsubishi Heavy Industries AC Gateway for integration of Mitsubishi Heavy Indsutries (MHI) Air Conditioners with KNX control systems. 1. Main Features Direct connection to KNX TP-1 (EIB)

More information

TAC I/NETTM MR-AHU-HP. Application Specific Controller

TAC I/NETTM MR-AHU-HP. Application Specific Controller TAC I/NETTM MR-AHU-HP Both the MR-AHU and MR-HP controllers are application specific controllers (ASCs). The intention of the design is to reduce total install cost through pre-engineered control algorithms

More information

Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5

Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5 Model Number Single head system Features Parameterization interface for the application-specific adjustment of the sensor setting via the service program ULTRA 000 programmable switch outputs Hysteresis

More information

Contents. Document information

Contents. Document information User Manual Contents Document information... 2 Introduction... 3 Warnings... 3 Manufacturer... 3 Description... Installation... Configuration... Troubleshooting...11 Technical data...12 Device Scope: PCB

More information

Inwall 4 Input / 4 Output Module

Inwall 4 Input / 4 Output Module Inwall 4 Input / 4 Output Module IO44C02KNX Product Handbook Product: Inwall 4 Input / 4 Output Module Order Code: IO44C02KNX 1/27 INDEX 1. General Introduction... 3 2. Technical data... 3 2.1 Wiring Diagram...

More information

Telephone- and leased line modem for industrial applications TD-36

Telephone- and leased line modem for industrial applications TD-36 Telephone- and leased line modem for industrial applications TD-36 Modem for industrial PSTN- and leased line applications The TD-36 is an analogue V.34 PSTN modem as well as an industrial 2-wire leased

More information

Power-monitoring unit PowerLogic System. Technical data sheet. Power Meter Series 800

Power-monitoring unit PowerLogic System. Technical data sheet. Power Meter Series 800 Power-monitoring unit PowerLogic System Technical data sheet 2003 Power Meter Series 800 Function and characteristics PB100313 The PowerLogic Power Meter Series 800 offers all the high-performance measurement

More information

Name Description Model Number. Parameters Min. Typ. Max. Note. Vaux Voltage 9.8 V 12 V 13.2 V Auxiliary Supply Voltage

Name Description Model Number. Parameters Min. Typ. Max. Note. Vaux Voltage 9.8 V 12 V 13.2 V Auxiliary Supply Voltage Description Supports DALI interface driver Programming Supports 0-10V Programmable Driver Programming Supports Other Controllers (TDD-ANPNx, SDD-AAPNx) Off-line programming capability Auto programming

More information

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 55 Series - General purpose relays 7-10 A Features 55.12 55.13 55.14 Printed circuit mount, general purpose 2, 3 & 4 Pole relays 55.12-2 Pole 10 A 55.13-3 Pole 10 A 55.14-4 Pole 7 A AC coils & DC coils

More information

Modbus Server SAMSUNG Air Conditioners

Modbus Server SAMSUNG Air Conditioners IntesisBox Server SAMSUNG Air Conditioners Gateway for monitoring and control of Samsung Air Conditioning Systems from any master device TCP or RTU (BMS, PLC, SCADA, HMI, TouchPanel ) Master TCP Master

More information

IntesisBox. KNX SAMSUNG Air Conditioning. Gateway for integration of Samsung air conditioners into KNX control systems. RS485.

IntesisBox. KNX SAMSUNG Air Conditioning. Gateway for integration of Samsung air conditioners into KNX control systems. RS485. IntesisBox KNX SAMSUNG Air Conditioning Gateway for integration of Samsung air conditioners into KNX control systems. Integrate Samsung Air Conditioners into KNX. KNX EIB Bus IntesisBox RS485 MIM-B13x/B04A

More information

38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A

38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A 38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A 38 SERIES Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit EMR Electromechanical

More information

Input signal Maximum Range Accuracy. Thermocouple E -50 to 700 C (-58 to 1832 F) ±1 C

Input signal Maximum Range Accuracy. Thermocouple E -50 to 700 C (-58 to 1832 F) ±1 C F4 Process Controller Installation and Operation Guide SAFETY ALERTS The symbols below are used on the equipment and throughout this document to draw the user s attention to important operational and safety

More information

User Guide Reflow Toaster Oven Controller

User Guide Reflow Toaster Oven Controller User Guide Reflow Toaster Oven Controller Version 1.5-01/10/12 DROTEK Web shop: www.drotek.fr SOMMAIRE 1. Introduction... 3 2. Preparation of THE REFLOW CONTROLLER... 4 2.1. Power supply... 4 2.2. USB

More information

MAKING MODERN LIVING POSSIBLE. AK-SC255 On-Site Installation Guide DANFOSS ELECTRONIC CONTROLS & SENSORS

MAKING MODERN LIVING POSSIBLE. AK-SC255 On-Site Installation Guide DANFOSS ELECTRONIC CONTROLS & SENSORS MAKING MODERN LIVING POSSIBLE AK-SC255 On-Site Installation Guide DANFOSS ELECTRONIC CONTROLS & SENSORS How to Use This Guide Read this Guide completely as you install and start up your new AK-SC 255 controller.

More information

NL708 (XWA11V) Walk-In Temp / Door /Alarm / Light Module

NL708 (XWA11V) Walk-In Temp / Door /Alarm / Light Module NL708 (XWA11V) Walk-In Temp / Door /Alarm / Light Module 1. General Description 1 2. General Warnings 1 3. Interface 2 4. Temp Alarms Setting 3 5. Programming 3 6. Light Management 4 7. Installation and

More information

Digital input modules

Digital input modules 8 172 TX-I/O Digital input modules TXM1.8D TXM1.16D Two fully compatible versions: TXM1.8D: 8 inputs, each with a three-color LED (green, yellow or red) TXM1.16D: As TXM1.8X, but 16 inputs, each with a

More information

PD 100A. Printing data system

PD 100A. Printing data system PD 100A Printing data system Operating instructions ENGLISH IMPORTANT: Read these instructions carefully before installing and using the device; do not forget following all additional information. Keep

More information

Room Controllers. SER8300 Line Voltage Fan Coil Room Controller with SC3000 Relay Pack

Room Controllers. SER8300 Line Voltage Fan Coil Room Controller with SC3000 Relay Pack Compatible with SmartStruxure solution SmartStruxure Lite solution Room Controllers Line Voltage Fan Coil Room Controller with SC3000 Relay Pack Application specific controller with customizable covers

More information

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q605 0054 R0001

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q605 0054 R0001 Analogue Input, -fold, MDRC, GH Q605 005 R0001 The analogue input is a DIN rail mounted device for insertion in the distribution board. It is connected to the EIB via the bus connecting terminal supplied.

More information

IntesisBox KNX Modbus TCP master

IntesisBox KNX Modbus TCP master IntesisBox KNX TCP master Gateway for integration of TCP slave devices into KNX control systems. Integrate any TCP slave device into KNX. KNX TCP slave EIB Bus IntesisBox Ethernet slave LinkBoxEIB Configuration

More information

TAC I/NETTM. Process Control Unit

TAC I/NETTM. Process Control Unit TAC I/NETTM 7756 Process Control Unit TAC s 7756 Process Control Unit (PCU), part of the TAC I/NETTM family of products, provides direct control and monitoring of process functions from a Peer-to-Peer

More information

Introduction. Refrigerant Leak Detecting System. Feature and Benefits

Introduction. Refrigerant Leak Detecting System. Feature and Benefits PSC European Refrigeration Controls Catalogue Catalog Section 9 Product Bulletin PD-GAS-E Refrigerant Leak Detecting System Introduction This range of refrigerant leak detecting systems is designed for

More information

Talon and Talon SR User Manual

Talon and Talon SR User Manual Talon and Talon SR User Manual Brushed DC motor controller Version 1.3 Cross the Road Electronics, LLC www.crosstheroadelectronics.com Cross The Road Electronics, LLC Page 1 4/2/2013 Device Overview Clear,

More information

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER Application : The RISH CON - Hz transducer is used for frequency measurement. The output signal is proportional to measured frequency and is either load independent DC Current or load independent DC Voltage.

More information

RI-215A Operator s Manual. Part Number: 71-0045RK Revision 0 Released: 10/3/05

RI-215A Operator s Manual. Part Number: 71-0045RK Revision 0 Released: 10/3/05 RI-215A Operator s Manual Part Number: 71-0045RK Revision 0 Released: 10/3/05 Warranty RKI Instruments, Inc., warrants gas alarm equipment sold by us to be free from defects in materials and workmanship,

More information

ModBus Server - KNX. Gateway for integration of KNX equipment into Modbus (RTU and TCP) control systems.

ModBus Server - KNX. Gateway for integration of KNX equipment into Modbus (RTU and TCP) control systems. IntesisBox ModBus Server - KNX Gateway for integration of KNX equipment into Modbus (RTU and TCP) control systems. Integrate KNX based lighting control into your SCADA, BMS, PLC "talking" Modbus. Master

More information

RVL470. Heating Controller. Building Technologies HVAC Products. Series B

RVL470. Heating Controller. Building Technologies HVAC Products. Series B 2 522 Heating Controller Series B RVL470 Multifunctional heating controller for use in residential and non-residential buildings; suitable for weather-dependent flow temperature control of heating zones

More information

Technote. Frese OPTIMA Compact actuators DN10-DN32. Application. Features thermic actuators. Features motoric actuators. Approval. www.frese.

Technote. Frese OPTIMA Compact actuators DN10-DN32. Application. Features thermic actuators. Features motoric actuators. Approval. www.frese. Page 1 of 6 Application Proportional 0-10V or 3-position modulating or On/ Off control of Frese OPTIMA Compact valves in heating, ventilating and air conditioning systems. The actuator can be mounted on

More information

PART 1 PRODUCT (GENERAL)...1.

PART 1 PRODUCT (GENERAL)...1. TABLE OF CONTENTS PART 1 PRODUCT (GENERAL)...1. 1.1--PRODUCT INTRODUCTION...1. 1.2--PRODUCT FEATURES...1. 1.3--TECHNICAL SPECIFICATIONS...2. 1.4--PHOTOMETRIC DATA...3. 1.5--SAFETY WARNING...4. PART 2 INSTALLATION...5.

More information

Product and Application Description

Product and Application Description Technical Product - Information Product and Application Description The room temperature controller UP 237K and UP 252K are available in the following colors, matching the design of the wall switch design

More information

1 Serial RS232 to Ethernet Adapter Installation Guide

1 Serial RS232 to Ethernet Adapter Installation Guide Installation Guide 10/100 Mbps LED (amber color ) Link/Activity LED (green color ) 1. Introduction Thank you for purchasing this 1-port RS232 to Ethernet Adapter (hereinafter referred to as Adapter ).

More information

Auto-tune PID. Temperature Controller BRAINCHILD FEATURES

Auto-tune PID. Temperature Controller BRAINCHILD FEATURES Auto-tune PID Temperature Controller FEATURES Easy-to-use Fuzzy modified PID heat & cool control Fast A-D sampling rate (5 times/s) Universal input (PT100, thermocouple) with high accuracy 18-bit A-D Analog

More information

HERZ-Thermal Actuators

HERZ-Thermal Actuators HERZ-Thermal Actuators Data Sheet 7708-7990, Issue 1011 Dimensions in mm 1 7710 00 1 7710 01 1 7711 18 1 7710 80 1 7710 81 1 7711 80 1 7711 81 1 7990 00 1 7980 00 1 7708 11 1 7708 10 1 7708 23 1 7709 01

More information

Panel Meters and Controllers Modular Panel Meter Type EDM 35

Panel Meters and Controllers Modular Panel Meter Type EDM 35 Panel Meters and Controllers Modular Panel Meter Type EDM 35 Modular digital panel meter, 3 1/2-digit Indicating or controlling current, voltage, resistance, temperature, tacho or frequency. Easy programming

More information

TABLE 1: Wiring Terminals. Connect to... 1C 1H 2C 2H 1H1C 2H1C 2H2C 3H2C

TABLE 1: Wiring Terminals. Connect to... 1C 1H 2C 2H 1H1C 2H1C 2H2C 3H2C Installation TURN OFF POWER TO THE SYSTEM AT THE MAIN POWER PANEL TO AVOID ELECTRICAL SHOCK. Installation should be carried out by an electrician or a qualified technician. 1.1 Find a Location for the

More information

SOUND LEVEL METER 94405

SOUND LEVEL METER 94405 SOUND LEVEL METER 94405 INSTRUCTION MANUAL REC FAST A/C 1. SAFETY INFORMATION Read the following safety information carefully before attempting to operate or service the meter. Use the meter only as specified

More information

USB-500 Series Stand-Alone, Low-Cost Data Loggers

USB-500 Series Stand-Alone, Low-Cost Data Loggers Stand-Alone, Low-Cost Data Loggers Features Stand-alone, remote data loggers Measure temperature, humidity, voltage, or current 1 or 2 channels Low cost, small size Battery powered Software Included, easy-to-use

More information

Taurus Super-S3 LCM. Dual-Bay RAID Storage Enclosure for two 3.5-inch Serial ATA Hard Drives. User Manual March 31, 2014 v1.2 www.akitio.

Taurus Super-S3 LCM. Dual-Bay RAID Storage Enclosure for two 3.5-inch Serial ATA Hard Drives. User Manual March 31, 2014 v1.2 www.akitio. Dual-Bay RAID Storage Enclosure for two 3.5-inch Serial ATA Hard Drives User Manual March 31, 2014 v1.2 www.akitio.com EN Table of Contents Table of Contents 1 Introduction... 1 1.1 Technical Specifications...

More information

is then retained absolutely without interruption.

is then retained absolutely without interruption. Page 1 of 11 DC UPS uninterruptible power supplies - DC UPS module 15 A Compact design, only 50 mm wide Absolutely interruption-free buffering of power failures through immediate electronic connection

More information

TC 1818a. Operating Guide. Control Module SWM-015.5

TC 1818a. Operating Guide. Control Module SWM-015.5 TC 1818a Control Module Operating Guide SWM-015.5 This guide is intended solely for use by owners of Thermon HeatChek TM heat tracing control and monitoring units. This manual describes operation for TC

More information

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency echnical data sheet NV24A--RE Communicative globe valve actuator for 2-way and 3-way globe valves Actuating force 1000 N Nominal voltage AC/DC 24 V Control Modulating DC (0)2...10 V Variable Nominal stroke

More information

Communicating Thermostats. Add More Flexibility to Building Automation with New. Communicating Thermostats

Communicating Thermostats. Add More Flexibility to Building Automation with New. Communicating Thermostats Communicating Thermostats Add More Flexibility to Building Automation with New Communicating Thermostats More Choices. More Possibilities. From zone control to rooftop units and nearly everything in between,

More information

GREISINGER electronic GmbH

GREISINGER electronic GmbH T38.0.0X.6C-03 CO2 - Transmitter Operating Manual GT10 - CO2-1R GREISINGER electronic GmbH D - 93128 Regenstauf, Hans-Sachs-Straße 26 Tel.: +49 9402 / 9383-0, Fax: +49 9402 / 9383-33, email: info@greisinger.de

More information

Unidirectional Transmitter/ Receiver Units Introduction

Unidirectional Transmitter/ Receiver Units Introduction Unidirectional Transmitter/ Receiver Units Introduction Wireless Input/Output (I/O) connects directly to analog, discrete and pulse transducer signals. The signals are transmitted by radio and either re-created

More information

Tubular Analog model resolution: 0,5 mm (SLOW mode), 1 mm (FAST mode) Right angle Repeatibility: 0,7 mm Vdc

Tubular Analog model resolution: 0,5 mm (SLOW mode), 1 mm (FAST mode) Right angle Repeatibility: 0,7 mm Vdc Ultrasonic sensors for high precision detection of clear and transparent objects Clear object detection, inspection on transparent or highly reflective film and liquid level measurement Standard M18 tubular

More information

USB-500/600 Series Low-Cost Data Loggers and Accessories

USB-500/600 Series Low-Cost Data Loggers and Accessories Low-Cost Data Loggers and Accessories Features Stand-alone, remote data loggers and portable logger assistant Measure temperature, humidity, voltage, current, or event/state change 1 or 2 channels Low

More information

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features: Application : RISH Master 3490 DS measures important electrical parameters of Utility (in normal mode) & Generators (in Power back up) in three phase and single phase Network & replaces the multiple analog

More information

Manual. IP Sensor and Watchdog IPSW2210. I P S W 2 2 1 0 M a n u a l P a g e 1. Relay Output. Power input. 12VDC adapter LED Indicators. 2 Dry.

Manual. IP Sensor and Watchdog IPSW2210. I P S W 2 2 1 0 M a n u a l P a g e 1. Relay Output. Power input. 12VDC adapter LED Indicators. 2 Dry. IP Sensor and Watchdog IPSW2210 Manual Relay Output Power input 12VDC adapter LED Indicators 1 wire 2 Dry Output Green : Power Yellow: Link temperature & humidity contact inputs LED indicator sensor input

More information

Controls for fan coil units and cassettes

Controls for fan coil units and cassettes Controls for fan coil units and cassettes Selection of controls for use with fan coil & cassette units. Stand alone, selection guide Control unit Motor Standard QZAZ-04-10 QZAZ-04-20 QZAZ-04-75 QZAZ-05-11

More information

93.68/93.69. Time scale: from 0.1s to 6h Multi-function For use with 34.51 (EMR) and 34.81 (SSR) relays. Screw terminal and push-in terminal

93.68/93.69. Time scale: from 0.1s to 6h Multi-function For use with 34.51 (EMR) and 34.81 (SSR) relays. Screw terminal and push-in terminal Series - Timed socket for 34 series Features.68/.69 Slim timed sockets for 34 series, 6.2 mm wide Timer adjustment via top mounted rotary knob accessible after assembly Control signal terminal DIP-switch

More information

38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A

38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A 38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit EMR Electromechanical Relays

More information

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems 3 072 RDJ10RF RCR10/433 Wireless room temperature controller with 24-hour time switch and LCD Programmable, for heating systems RDJ10RF/SET Operating modes: Automatic, Comfort, Energy Saving, and Frost

More information

Durant PGM. For Sales and Support, Contact Walker EMD Toll-free: (800) 876-4444 Tel: (203) 426-7700 Fax: (203) 426-7800 www.walkeremd.

Durant PGM. For Sales and Support, Contact Walker EMD Toll-free: (800) 876-4444 Tel: (203) 426-7700 Fax: (203) 426-7800 www.walkeremd. Eclipse Series Digital Panel Meters Installation and Operation Manual Number 57700-900-05 Models: 5770X-40X - DC Volts 5770X-4X - AC Volts 5770X-42X - DC Amps 5770X-43X - AC Amps 5770X-44X - 5A AC 5770X-45X

More information

Power Meter Series 700

Power Meter Series 700 PowerLogic power-monitoring units Power Meter Series 700 Technical data sheet 2007 Functions and characteristics E90463 The PowerLogic Power Meter Series 700 offers all the measurement capabilities required

More information

SMART SENSOR COLLECTION

SMART SENSOR COLLECTION TEMPERATURE SENSOR This sensor measures temperature in degrees Celsius or Fahrenheit. It works with all SensorHawk base units (SensorHawk-2, SensorHawk-8 and SensorHawk8/20) as well as the SecurityHawk-8

More information

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410 The INTEG is an Ethernet I/O (digital, analog) device that monitors and controls a small set of process signals. functions as both basic I/O for integration with another application or system AND as a

More information

All of the above software and firmware are included in the VAV-B Package. Contact Customer Service or Technical Support for this, or for cables.

All of the above software and firmware are included in the VAV-B Package. Contact Customer Service or Technical Support for this, or for cables. Updated 03-07-2012 VAV-B Programming Manual CBAS version 11.1.9 or newer Firmware version 13.7 or newer on Host controller USB to 485 commissioning cable (need part number) or USB Isolator (B&B Electronics

More information

USB-500 Series Low-Cost Data Loggers and Accessories

USB-500 Series Low-Cost Data Loggers and Accessories Low-Cost Data Loggers and Accessories Features Stand-alone, remote data loggers and portable logger assistant Measure temperature, humidity, voltage, current, or event/state change 1 or 2 channels Low

More information

Product Specification instalert Rapid Messenger Variable Message Sign

Product Specification instalert Rapid Messenger Variable Message Sign instalert 2 units to cover any application instalert 18 (ia18): 18 x 28 full matrix instalert 24: (ia24): 24 x 60 full matrix Size, Weight without battery ia18: 30 x 20 x 2.74, 29 lbs ia24: Folds to fits

More information

Series LC6D/LC6C. To power supply PLC. LC6C dedicated teaching box P.971. Options P.973

Series LC6D/LC6C. To power supply PLC. LC6C dedicated teaching box P.971. Options P.973 Series LCD To power supply Electric Actuator Series LCC Stepper Motor Driver LCD Series LX Dedicated Stepper Motor Driver and Positioning Driver Series LCD/LCC PLC Positioning unit (Not incl. To be provided

More information

How To Power A Power Control On An Ip40 (Ipl) With A Power Supply (Iplug) With An Ip20 Controller (Iphones) With Power Control (Power Control) With No Antenna) With The Ip20 (Power)

How To Power A Power Control On An Ip40 (Ipl) With A Power Supply (Iplug) With An Ip20 Controller (Iphones) With Power Control (Power Control) With No Antenna) With The Ip20 (Power) MODEL NUMBER: ISC910-1-0-GB-XX ISC911-5-0-GB-XX IXP20 CONTROLLER SPECIFICATIONS Working Environment Plastic Housing... Power ImproX IXP20 Controller INSTALLATION MANUAL Designed to work in an indoor (dry)

More information

HOBO U14 Data Logger User Manual

HOBO U14 Data Logger User Manual HOBO U14 Data Logger User Manual The U family of data loggers offers reliability and convenient monitoring for applications that require higher accuracy, better resolution, more memory, or USB connectivity

More information

DCDC-USB. 6-34V 10A, Intelligent DC-DC converter with USB interface. Quick Installation Guide Version 1.0c P/N DCDC-USB

DCDC-USB. 6-34V 10A, Intelligent DC-DC converter with USB interface. Quick Installation Guide Version 1.0c P/N DCDC-USB DCDC-USB 6-34V 10A, Intelligent DC-DC converter with USB interface Quick Installation Guide Version 1.0c P/N DCDC-USB Introduction The DCDC-USB is a small yet powerful DC-DC power supply designed to power

More information

IntesisBox Modbus Server Fidelio IP

IntesisBox Modbus Server Fidelio IP IntesisBox Server Fidelio IP Gateway for integration of Micros Fidelio Ho management system into (RTU and TCP) enabled control systems. Integrate your Micros Fidelio Ho management system into your master

More information

Combi switchbox with integrated 3/2 way pilot valve

Combi switchbox with integrated 3/2 way pilot valve H Combi switchbox with integrated 3/2 way pilot valve Construction The GEMÜ combi switchbox with integrated 3/2 way pilot valve for pneumatically operated quarter turn actuators has a micro-processor controlled

More information

CD-Pxx-00-1 Series Duct Mount CO 2 Transmitter

CD-Pxx-00-1 Series Duct Mount CO 2 Transmitter CD-Pxx-00-1 Series Duct Mount CO 2 Transmitter Product Bulletin CD-Pxx-00-1 Code No. LIT-216525 Issued December 6, 2010 Supersedes September 12, 2008 Johnson Controls offers a complete line of Carbon Dioxide

More information

38 SERIES. Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.

38 SERIES. Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6. 38 Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A 38 Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit 6.2 mm wide EMR - DC, AC or AC/DC

More information

ZC-24DO CANopen I/O Module: 24 Digital Outputs

ZC-24DO CANopen I/O Module: 24 Digital Outputs Z-PC Line EN ZC-24DO CANopen I/O Module: 24 Digital Outputs Installation Manual Contents: - General Specifications - Technical Specifications - Installation Rules - Electrical connections - DIP-switches

More information

Digital display DA 48

Digital display DA 48 Loop powered plug-in LCD display No auxiliary energy source needed Scale freely adjustable on site Can be turned to any position Suitable for any 0 ma transmitter with EN 175301-803A connector Digital

More information