Addendum to the Operating Instructions

Size: px
Start display at page:

Download "Addendum to the Operating Instructions"

Transcription

1 Drive Technology \ Drive Automation \ System Integration \ Services Addendum to the Operating Instructions MOVIMOT with AS-Interface and AC Motor DT/DV Unit Replacement MOVIMOT MM..C -> MM..D with MLK3A Option Edition 1/ / EN

2 SEW-EURODRIVE Driving the world

3 Contents Contents 1 General information Structure of the safety notes Rights to claim under warranty Exclusion of liability Copyright Product names and trademarks Other applicable documentation Determining the required retrofit set Mechanical installation Scope of delivery of the retrofit set Disassembly MOVIMOT MM..C Assembly Startup Important notes on startup Control element settings Starting up the MOVIMOT drive with AS-Interface

4 1 General information Structure of the safety notes MOVIMOT Æ with AS-Interface and AC Motor DT/DV Äì Unit Replacement MOVIMOT Æ MM..C -> MM..D 1 General information 1.1 Structure of the safety notes Meaning of signal words The following table shows the graduation and meaning of the signal words for safety notes, warnings regarding potential risks of damage to property, and other notes. Signal word Meaning Consequences if disregarded DANGER! Imminent hazard Severe or fatal injuries WARNING! Possible dangerous situation Severe or fatal injuries CAUTION! Possible dangerous situation Minor injuries NOTICE Possible damage to property Damage to the drive system or its environment INFORMATION Useful information or tip: Simplifies handling of the drive system Design of the section-related safety notes Section-related safety notes do not apply to a specific action, but to several actions pertaining to one subject. The symbols used either indicate a general hazard or a specific hazard. This is the formal structure of a safety note for a specific section: SIGNAL WORD! Type and source of danger. Possible consequence(s) if disregarded. Measure(s) to prevent the danger Design of the embedded safety notes Embedded safety notes are directly integrated into the instructions just before the description of the dangerous action. This is the formal structure of an embedded safety note: SIGNAL WORD! Type and source of hazard. Possible consequence(s) if disregarded. Measure(s) to prevent the hazard. 4

5 General information Rights to claim under warranty Rights to claim under warranty A requirement of fault-free operation and fulfillment of any rights to claim under limited warranty is that you adhere to the information in the documentation. Therefore read the documentation before you start working with the unit. 1.3 Exclusion of liability You must comply with the information contained in this documentation to ensure safe operation and to achieve the specified product characteristics and performance features. SEW-EURODRIVE assumes no liability for injury to persons or damage to equipment or property resulting from non-observance of these operating instructions. In such cases, any liability for defects is excluded. 1.4 Copyright 213 SEW-EURODRIVE. All rights reserved. Unauthorized duplication, modification, distribution or any other use of the whole or any part of this documentation is strictly prohibited. 1.5 Product names and trademarks All product names in this documentation are trademarks or registered trademarks of their respective titleholders. 1.6 Other applicable documentation This additional information does not replace the detailed operating instructions. Only electrical specialists are allowed to perform installation and startup observing applicable accident prevention regulations and the "MOVIMOT MM..D with AS-Interface and AC motor DRS/DRE/DRP" operating instructions. 5

6 1 General information Determining the required retrofit set 1.7 Determining the required retrofit set To retrofit the MOVIMOT drive with AS-Interface and AC motor DT/DV MOVIMOT MM..C -> MOVIMOT MM..D, you require a complete retrofit set with MOVIMOT MM..D inverter, AS-Interface option MLK3A and connection box. The following illustration shows an example of how to determine the type designation of the required retrofit set based on the nameplate data of the current motor: SEW-EURODRIVE Typ Nr. KW 5Hz 6Hz r/min Bremse kg 73 Bruchsal / Germany KA77DT9L4/BMG/MM15/RJ1A/AND3/AZSK 3~ IM 1, 5 / 5 Hz cos V 38-5 A V 38-5 A 22 / 14 IP V23 Ma 665 Nm 2 Nm IEC 34 B3,99 3,5 3,5 54 Kl F Gleichrichter i 64,75 :1 Schmierstoff Made in Germany [1] MOVIMOT MM..C MOVIMOT MM..D [2] [3] MM3 MM 3C-53-3 MM 3D /min MM5 MM 5C-53-3 MM 5D /min 1 AVSK AVSK MM7 MM 7C-53-3 MM 7D-53- MM11 MM 11C-53-3 MM 11D-53- MM15 MM 15C-53-3 MM 15D-53- AZSK AZSK MM22 MM 22C-53-3 MM 22D-53- MM3 MM 3C-53-3 MM 3D-53- MM3 MM 3C-53-3 MM 3D-53- MM3X MM 3XC-53-3 MM 4D-53- AND3 / AZSK AND3 / AZSK AZSX AZZK AND3 / AZSX AND3 / AZZK MLK3A (AS-Interface-Option) [4] MM 15D-53- / / AND3 / AZSK / MLK3A [1] Power MOVIMOT [2] Nominal speed [3] Plug connector [4] Required retrofit set

7 Mechanical installation Scope of delivery of the retrofit set 2 2 Mechanical installation 2.1 Scope of delivery of the retrofit set Check whether the MOVIMOT MM..D retrofit set was delivered complete using the following figure. [A] [B] [C] [D] [G] [F] [E] [A] Connection box [B] Connection board with 1 or several connected plug connectors [C] Connection cable [D] MOVIMOT inverter [E] 4 screws [F] 2 screws [G] PE screw The parts [A] to [G] are already assembled when the retrofit set is delivered. 7

8 2 Mechanical installation Disassembly MOVIMOT MM..C 2.2 Disassembly MOVIMOT MM..C WARNING Electric shock caused by dangerous voltages in the connection box. Severe or fatal injuries. De-energize the drive using a suitable cut-off device before removing the MOVIMOT inverter. Wait for at least 1 minute before removing the MOVIMOT inverter. Disassemble the MOVIMOT MM..C inverter and the connection box as follows: 1. Unscrew the MOVIMOT inverter from the connection box. 2. Write down the current settings of the control elements, see chapter "Control element settings" You need the settings during the startup of the MOVIMOT MM..D drive Only for brake motors: Disconnect the connection cables of the brake [1]. [1]

9 Mechanical installation Disassembly MOVIMOT MM..C 2 4. Only for motors without a brake: Unscrew the BW braking resistor from the connection box. The braking resistor and the screws will be re-installed. 5. Unscrew the connection board unit from the connection box Be careful not to damage the cables. 6. Unscrew the connection box from the motor

10 2 Mechanical installation Assembly 7. Clean the sealing surface [1]. A new gasket is already installed in the new connection box. Do not use the used gasket. [1] Assembly Assemble the MOVIMOT MM..D inverter and the connection box as follows: 1. Loosen the 2 screws [F] and remove the connection board [B] from the connection box. Do not disconnect the connection cables of the plug connectors from the terminals of the connection board. [B] [F] 2. Place the connection box [A] onto the motor and secure it using 4 screws. (tightening torque Nm / lb.in) The recess for the terminal board on the underside of the connection box must point toward the fan guard. [A]

11 X1: 13 X1: 14 X1: 15 Mechanical installation Assembly 2 3. Plug the connection cables [C] onto the bolts of the terminal board as shown in the wiring diagram. Fasten the connection cables with the already installed nuts. (tightening torque Nm / lb.in) YE WH BN 4. Connect the connection cables [C] to the terminals [1] on the connection board according to the wiring diagram to the right. BU RD BK W2 U2 V2 W1 V1 U YE WH BN BU RD BK [C] [1] 5. Insert the connection board [B] into the connection box and secure it using 2 screws [F]. (tightening torque Nm / lb.in) Be careful not to damage or squeeze the cables. 6. Only for brake motors: Connect the connection cables of the BE.. brake as follows: Red to terminal X1:13 White to terminal X1:14 Blue to terminal X1:15 (tightening torque of the terminals Nm / 7 1 lb.in) [B] [F] RD WH BL BE

12 X1: 13 X1: 14 X1: 15 2 Mechanical installation Assembly 7. Only for motors without a brake: Install the BW.. braking resistor in the terminal box using 2 screws. (tightening torque Nm / 12 14lb.in) Connect the BW.. braking resistor to terminals X1:13 and X1:15. (tightening torque of the terminals Nm / 7 1 lb.in) Terminal X1:14 must remain free. BW1 / BW Set all control elements (potentiometer, switch, and DIP switch) of the new inverter according to the settings specified in chapter "Control element settings". 9. Place the MOVIMOT inverter onto the connection box and secure it using 4 screws. (tightening torque 3. Nm / 27 lb.in)

13 Startup Important notes on startup I 3 3 Startup 3.1 Important notes on startup INFORMATION You must comply with the general safety notes in chapter "Safety Notes" during startup. WARNING Risk of crushing due to missing or defective protective covers. Severe or fatal injuries. Install the protective covers of the plant according to the instructions, also see the operating instructions of the gear unit. Never start up the MOVIMOT drive if the protective covers are not installed. WARNING Electric shock caused by dangerous voltages in the connection box. Dangerous voltages may still be present for up to one minute after disconnection from the power supply. Severe or fatal injuries. De-energize the MOVIMOT drive using a suitable cut-off device before removing the MOVIMOT inverter. Secure the drive against unintended re-connection to the voltage supply. Wait for at least 1 minute before removing the MOVIMOT inverter. WARNING Danger of burns due to hot surfaces of the MOVIMOT drive (especially the heat sink) or external options. Severe injuries. Do not touch the MOVIMOT drive and external options until they have cooled down sufficiently. WARNING Unit malfunction due to incorrect unit setting. Severe or fatal injuries. Observe the startup instructions. The installation must only be carried out by qualified personnel. Only use settings that are consistent with the function. INFORMATION To ensure fault-free operation, do not disconnect or connect power or signal cables during operation. INFORMATION Remove paint protection cap from the status LED before startup. Remove paint protection film from the nameplates before startup. Observe a minimum switch-off time of 2 seconds for the line contactor K11. 13

14 3 I Startup Control element settings 3.2 Control element settings INFORMATION The setpoint potentiometer f1 and the switch f2 are at the same position at the new MOVIMOT MM..D inverter as in the replaced MOVIMOT MM..C inverter Setpoint potentiometer f1 Use the f1 potentiometer to adjust setpoint f1. f[hz] 1 f [1] Potentiometer setting [1] f1: Switch f Use the f2 switch to adjust setpoint f2. Switch f2 Detent position Setpoint f2 [Hz] Minimum frequency [Hz] f2: Switch t1 3 Use switch t1 to set the acceleration of the MOVIMOT drive. The ramp times are based on a setpoint step change of 15 rpm (5 Hz) Switch t1 Detent position Ramp time t1 [s] t1: 14

15 Startup Control element settings I Setting the DIP switches Write down the DIP switch settings of the current MOVIMOT MM..C inverter into the following fields (ON or OFF): 5 6 ON CTS ON CTS S3 S4 MOVIMOT MM..C S3/1 S3/2 S3/3 S3/4 (ON / OFF) S3/5 S3/6 S4/1 S4/2 S4/3 S4/4 S4/5 S4/6 S3 ON ON S ON OFF S1 ON S2 ON S MOVIMOT MM..D S2 S1 S Set the DIP switches of the new MOVIMOT MM..D inverter according to the notes in the diagram above. 15

16 3 I Startup Control element settings DIP switch S1: S Meaning Binary coding RS-485 unit address Motor protection Motor power rating PWM frequency No-load damping ON Off OFF On Motor one stage smaller Motor adjusted Variable (16, 8, 4 khz) On 4 khz Off DIP switch S2: S Meaning Brake type Brake released without enable ON OFF Optional brake Standard brake Operating mode Speed monitoring Binary encoding additional functions On V/f On Off VFC Off 16

17 Startup Control element settings I Setting the 24 V supply via switch S5 The switch S5 [1] is located on the connection board. [1] [1] Size 1 Size [1] Switch S5 Use switch S5 to set the type of 24 V supply. Switch Switch S5 = "1" S5 24 V voltage supply Supplying the MOVIMOT using AUX PWR (e.g. black AS-Interface cable) 24V AS- AS + 1 BK YE Switch S5 = "" Supplying MOVIMOT via the AS-Interface data cable S5 1 24V AS - AS + YE S5: 17

18 3 I Startup Starting up the MOVIMOT drive with AS-Interface 3.3 Starting up the MOVIMOT drive with AS-Interface WARNING Electric shock caused by dangerous voltages in the connection box. Severe or fatal injuries. De-energize the drive using a suitable cut-off device before removing the MOVIMOT inverter. Wait for at least 1 minute before removing the MOVIMOT inverter. INFORMATION The MOVIMOT MM..D inverter with AS-Interface option MLK3A is functionally compatible with the MOVIMOT MM..C...-3 inverter. The AS-Interface profile, the I/O configuration and the ID code of the inverters are identical. 1. Remove the MOVIMOT inverter from the connection box. 2. Make sure that no Drive Ident Module for DR motor types is plugged into the MOVIMOT inverter. [1] [1] Slot for Drive Ident Module 3. Set all switches and DIP switches of the new inverter according to the settings specified in chapter "Control element settings". 4. Set the AS-Interface address as specified in the following chapters. 5. Place the MOVIMOT inverter onto the connection box and screw it on. 6. Switch on the following voltages. AS-Interface voltage DC 24 V auxiliary voltage (only for 24 V supply via the black AUX-PWR cable) Supply voltage

19 Startup Starting up the MOVIMOT drive with AS-Interface I Assigning the slave address MOVIMOT drives with MLK3.A AS-Interface option are set to address by default. You have the following options for assigning the AS-Interface address of the MOVIMOT inverter with MLK3.A AS-Interface option (address 1-31): Addresses are assigned automatically within a configured AS-Interface system when replacing a MOVIMOT drive with MLK3.A AS-Interface option. The following prerequisites must be fulfilled: The new MOVIMOT drive with AS-Interface option MLK3.A must have the address. If you need to replace several MOVIMOT drives with AS-Interface option MLK3.A, you must replace them individually (one after the other). Manual address assignment via the plant master The drives must be connected to the AS-Interface cable one after another. Doing so prevents several MOVIMOT drives with AS-Interface option MLK3.A from having assigned the same address. Manual address assignment using a hand-held AS-Interface programming device. Observe the notes in the next chapter when connecting the MOVIMOT drives with AS-Interface option MLK3.A to the AS-Interface cable. Assigning the slave address using a hand-held programming device Hand-held AS-Interface programming units offer the following functions: Reading out and changing an AS-Interface slave address Reading out the AS-Interface profile Reading out and changing the data and parameter bits Function check and test run. Hand-held programming devices do not provide sufficient current for the operation. This is why an external voltage supply (AUX-PWR) is required for the function check and the test run. When using a hand-held programming device, you need a 2-core connection cable that fits onto the AS-interface plug connector of MOVIMOT (see the following figure). 1: AS-Interface : V24 [1] 1 2 3: AS-Interface - 4: 24V [1] [1] Do not connect pin 2 and 4 for the address assignment! NOTICE! The hand-held programming device can be damaged if not connected properly. The hand-held programming device may only be connected via pins 1 "AS-Interface +" and 3 "AS-Interface -" with the AS-Interface plug connector. Prior to the address assignment via a hand-held programming device, switch S5 in the MOVIMOT terminal box must be set to "1"! After the address assignment you have to set the S5 according to the kind of 24 V voltage supply. 19

20 3 I Startup Starting up the MOVIMOT drive with AS-Interface Example: Disconnect the AS-Interface nodes from the AS-Interface network one at a time and assign addresses via the hand-held programming device (A). Then reconnect the respective AS-Interface node to the AS-Interface network (B). A B MOVIMOT [1] [1] AS-Interface hand-held programming device AS-interface MLK3A binary slave AS-Interface MLK3A Protocol variant AS-Interface profile I/O configuration ID code ext. ID code1 ext. ID code2 Address Binary AS-Interface slave with a S-7.F profile "four bit I/O mode slave" S-7.F 7 hex F hex F hex E hex 1 31 (factory setting: ), can be changed as often as required 2

21 Startup Starting up the MOVIMOT drive with AS-Interface I Data AS-Interface master MOVIMOT The following table shows the 4 data bits that the AS-Interface master sends to the MOVIMOT inverter via the AS-Interface: AS-Interface bit DO DO1 DO2 DO3 Function (page 22) CW rotation / stop CCW rotation / stop Speed f2 / speed f1 Reset 1) / controller enable 1) In the event of an edge change "" "1" (only effective in case of an error) INFORMATION To enable the drive, AS-Interface bit DO3 "Reset / controller enable" must be set Data MOVIMOT AS-Interface master The following table shows the 4 data bits that the MOVIMOT inverter sends to the AS-Interface master via the AS-Interface: AS-Interface bit DI DI1 Function Ready signal : The MOVIMOT drive is not ready for operation 1: The MOVIMOT drive is ready for operation Manual mode : MOVIMOT control via AS-Interface 1: MOVIMOT control via manual operation DI2 Sensor input 1 : The signal of sensor 1 = "" 1: The signal of sensor 1 = "1" DI3 Sensor input 2 : The signal of sensor 2 = "" 1: The signal of sensor 2 = "1" 21

22 3 I Startup Starting up the MOVIMOT drive with AS-Interface Setpoint scaling via parameter bits The following table lists the parameter bits for setpoint scaling. The setpoint scaling does only affect setpoint f1 that can be set externally. Setpoint f2 and the minimum frequency are not affected by the scaling. The following table lists the possible setpoint frequencies for setpoint potentiometer f1 = 1 Hz (3 rpm) and f1 = 5 Hz (15 rpm): Parameter bits Factor Setpoint frequency [Hz] Setpoint frequency [Hz] P3 P2 P1 P for f1 = 1 Hz f1 = 5 Hz Inverter behavior depending on the AS-Interface bits Inverter behavior Supply system X1: L1-L3 AS-Interface bit DO3 DO2 DO DO1 Reset / controller enable Speed f2 / speed f1 CW rotation / stop CCW rotation / stop Status LED Inverter off x x x Flashing yellow Inverter off 1 x x x yellow Stop, no supply system 1 x x x Flashing yellow Stop 1 1 x yellow CW with f green CCW with f green CW with f green CCW with f green Stop 1 1 x 1 1 yellow Legend = No voltage 1 = Voltage x= Any 22

23

24 SEW-EURODRIVE Driving the world SEW-EURODRIVE Driving the world SEW-EURODRIVE GmbH & Co KG P.O. Box BRUCHSAL GERMANY Phone Fax

Addendum to the Operating Instructions

Addendum to the Operating Instructions Drive Technology \ Drive Automation \ System Integration \ Services Addendum to the Operating Instructions Safety-Rated Encoders Functional Safety for CMP Synchronous Servomotors CMP40 CMP100 CMPZ71 CMPZ100

More information

11 MOVIMOT and Bus Diagnostics

11 MOVIMOT and Bus Diagnostics MOVIMOT Status LED MOVIMOT and Bus. MOVIMOT Status LED Status LED 0 Exploration of Status LED Display The operating and fault messages are signaled by the three-colored LED display. LED color LED status

More information

Modular I/O System Analog and Digital Interface Modules

Modular I/O System Analog and Digital Interface Modules OPERATING INSTRUCTIONS Modular I/O System Analog and Digital Interface Modules Installation Operation Maintenance Document Information Document ID Title: Operating Instructions Modular I/O System Part

More information

Brake module AX5021. Documentation. Please read this document carefully before installing and commissioning the brake module!

Brake module AX5021. Documentation. Please read this document carefully before installing and commissioning the brake module! Documentation Brake module AX5021 Please read this document carefully before installing and commissioning the brake module! Version : 1.2 : 2012.03.05 Date Article-no. : TDmlAX-5021-0000-0200 Page 2/8

More information

Drive Technology \ Drive Automation \ System Integration \ Services. Manual. MOVITRAC B Simple Positioning Application Module

Drive Technology \ Drive Automation \ System Integration \ Services. Manual. MOVITRAC B Simple Positioning Application Module Drive Technology \ Drive Automation \ System Integration \ Services Manual MOVITRAC B Simple Positioning Application Module Edition 10/2010 17030412 / EN SEW-EURODRIVE Driving the world Contents Contents

More information

Compact Operating Instructions

Compact Operating Instructions Drive Technology \ Drive Automation \ System Integration \ Services Compact Operating Instructions MOVIMOT MM..D with AC Motor DT/DV Edition 11/2009 16885228 / EN SEW-EURODRIVE Driving the world Contents

More information

ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01

ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01 ABB Drives User s Manual Pulse Encoder Interface Module RTAC-0 Pulse Encoder Interface Module RTAC-0 User s Manual 3AFE 64486853 REV A EN EFFECTIVE:.5.00 00 ABB Oy. All Rights Reserved. Safety instructions

More information

Installation and safety instructions for AC/DC built-in devices

Installation and safety instructions for AC/DC built-in devices The device type and date of manufacture (week/year) can be found on the device rating plate. In the event of any queries about the device, please quote all the details given on the rating plate. For further

More information

ABB Drives. User s Manual HTL Encoder Interface FEN-31

ABB Drives. User s Manual HTL Encoder Interface FEN-31 ABB Drives User s Manual HTL Encoder Interface FEN-31 HTL Encoder Interface FEN-31 User s Manual 3AUA0000031044 Rev B EN EFFECTIVE: 2010-04-06 2010 ABB Oy. All Rights Reserved. 5 Safety instructions

More information

24 V Power Supply Installation Manual PS-A10H and PS-A10L

24 V Power Supply Installation Manual PS-A10H and PS-A10L 24 V Power Supply Installation Manual PS-A10H and PS-A10L November 2011 Part Number: 144-23928 Copyright 2011 Magnetek 1. Preface and Safety Magnetek manufactures products used as components in a wide

More information

Digi-Motor Installation Guide

Digi-Motor Installation Guide Digi-Motor Installation Guide Installation Video...located at marsdelivers.com Digi-Motor Installation Guide Digi-Motor For technical assistance with your Azure Digi-Motor, call the MARS technical support

More information

SIMATIC S7-300. Getting Started for First Time Users. Order No.: 6ZB5310-0NC02-0BA0 04/2007 A5E01094750-01

SIMATIC S7-300. Getting Started for First Time Users. Order No.: 6ZB5310-0NC02-0BA0 04/2007 A5E01094750-01 SIMATIC S7-300 Getting Started for First Time Users Order No.: 6ZB5310-0NC02-0BA0 04/2007 A5E01094750-01 Safety Guidelines This manual contains notices you have to observe in order to ensure your personal

More information

INSTALLATION INSTRUCTIONS WARN Works Contactor Kit Part Number: 66187

INSTALLATION INSTRUCTIONS WARN Works Contactor Kit Part Number: 66187 INSTALLATION INSTRUCTIONS WARN Works Contactor Kit Part Number: 66187 Your safety, and the safety of others, is very important. To help you make informed decisions about safety, we have provided installation

More information

AC 800M. EtherNet/IP DeviceNet Linking Device LD 800DN. Power and productivity for a better world TM SP1134

AC 800M. EtherNet/IP DeviceNet Linking Device LD 800DN. Power and productivity for a better world TM SP1134 AC 800M EtherNet/IP DeviceNet Linking Device LD 800DN SP1134 Power and productivity for a better world TM AC 800M EtherNet/IP DeviceNet Linking Device LD 800DN NOTICE This document contains information

More information

Bullet Camera. Installation Guide. Hangzhou Hikvision Digital Technology Co., Ltd. http://www.hikvision.com

Bullet Camera. Installation Guide. Hangzhou Hikvision Digital Technology Co., Ltd. http://www.hikvision.com Bullet Camera Installation Guide Hangzhou Hikvision Digital Technology Co., Ltd. http://www.hikvision.com 1 Thank you for purchasing our product. If there are any questions, or requests, please do not

More information

A1000 Cheat Sheet (Open Loop Vector)

A1000 Cheat Sheet (Open Loop Vector) A1000 Cheat Sheet (Open Loop Vector) The following procedure is a supplement to supplied with this equipment and will guide the user in properly wiring the A1000 and. It will also show the user how to

More information

SIMATIC NET. CP 243-2 AS-Interface Master B C. Preface Contents. Technical Description and Installation Instructions Interface to the User Program

SIMATIC NET. CP 243-2 AS-Interface Master B C. Preface Contents. Technical Description and Installation Instructions Interface to the User Program Preface Contents SIMATIC NET CP 243-2 AS-Interface Master Manual Technical Description and Installation Instructions Interface to the User Program 2 in the S7-200 CPU Access to the Data of the AS-i Slaves

More information

DRM75A 230V 20/100A DIN rail single phase two wire energy meter

DRM75A 230V 20/100A DIN rail single phase two wire energy meter DRM75A 230V 20/100A DIN rail single phase two wire energy meter 1.1 Safety instruction 1.2 Foreword 1.3 Performance criteria 1.4 Specifications 1.5 Basic errors 1.6 Description 1.7 Dimensions 1.8 Installation

More information

EX-RC1 Remote I/O Adapter

EX-RC1 Remote I/O Adapter EX-RC1 Remote I/O Adapter The EX-RC1 interfaces between Unitronics Vision OPLCs and remote I/O Expansion Modules distributed throughout your system. The adapter is connected to a PLC via CANbus. Each adapter

More information

PowerFlex 700H and 700S AC Drives Frame 11 Main Fan Capacitor Replacement Kit

PowerFlex 700H and 700S AC Drives Frame 11 Main Fan Capacitor Replacement Kit Installation Instructions PowerFlex 700H and 700S AC Drives Frame 11 Main Fan Capacitor Replacement Kit ATTENTION: The sheet metal cover and mounting screws on the ASIC Board located on the power structure

More information

ADM1TE 5/30A DIN rail single phase two wire energy meter

ADM1TE 5/30A DIN rail single phase two wire energy meter ADMTE 5/30A DIN rail single phase two wire energy meter. Safety instruction.2 Foreword.3 Performance criteria.4 Specifications.5 Basic errors.6 Description.7 Dimensions.8 Installation.9 Operating.0 Troubleshooting.

More information

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version) TECHNICAL DATASHEET #TD1102AX CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version) Part Number: Connector Amplifier CAPV-H-4-20MA-x complete with cable CAPV-4C-yM Where: x = current output

More information

PowerFlex 700L Frame 3A DC Bus Bar Conversion Kit

PowerFlex 700L Frame 3A DC Bus Bar Conversion Kit Installation Instructions PowerFlex 700L Frame 3A DC Bus Bar Conversion Kit ATTENTION: To avoid an electric shock hazard, ensure that all power to the power module has been removed before performing any

More information

MAXIGARD A1000 SPEED SWITCH. Introduction

MAXIGARD A1000 SPEED SWITCH. Introduction A102-05, Page 1 952-361-3026, INC. (Fax) 952-368-4129 327 LAKE HAZELTINE DRIVE, CHASKA, MN 55318 800-328-0738 MAXIGARD A1000 SPEED SWITCH Introduction The Maxigard A1000 speed switch is designed to monitor

More information

Sunny Boy Accessories SMA POWER BALANCER

Sunny Boy Accessories SMA POWER BALANCER Sunny Boy Accessories SMA POWER BALANCER Installation Guide SBUS-PowBal-IUS102810 IMUS-SBUS-PBL Version 1.0 US SMA America, LLC Legal Restrictions Copyright 2010 SMA America, LLC. All rights reserved.

More information

Technical Description

Technical Description abcxyz Contents 1. General...1 2. Block Diagram...2 3. First Steps...2 4. Technical Data...3 4.1 AS-Interface...3 4.2 Pin Out...4 4.3 Supply of Periphery...4 4.4 Inputs...5 4.5 Outputs...5 4.6 Mechanical

More information

BWO 155 BWO V BWO 155 Z BWO 155 ERT. Original operating instructions

BWO 155 BWO V BWO 155 Z BWO 155 ERT. Original operating instructions 90 C 80 C BWO 155 BWO 155 12V BWO 155 Z BWO 155 ERT Original operating instructions 70 C 60 C 50 C 40 C Deutsche Vortex GmbH & Co. KG Kästnerstraße 6 71642 Ludwigsburg Germany Fon: +49(0)7141.2552-0 E-Mail:

More information

Drive Technology \ Drive Automation \ System Integration \ Services. Manual. MOVIDRIVE MDX60B/61B Functional Safety

Drive Technology \ Drive Automation \ System Integration \ Services. Manual. MOVIDRIVE MDX60B/61B Functional Safety Drive Technology \ Drive Automation \ System Integration \ Services Manual MOVIDRIVE MDX60B/61B Functional Safety Edition 09/2010 17019613 / EN SEW-EURODRIVE Driving the world Contents Contents 1 Important

More information

Operating Instructions

Operating Instructions Operating Instructions Plug > Contents 1 Contents 1 Contents...2 2 General Information...2 3 Safety instructions...3 4 Conformity to standards...3 5 Function...3 6 Technical Data...4 7 Mounting...6 8 Installation...7

More information

Electronic Refrigerator Diagnostics

Electronic Refrigerator Diagnostics Electronic Refrigerator Diagnostics IMPORTANT SAFETY NOTICE The information in this presentation is intended for use by individuals possessing adequate backgrounds of electrical, electronic, & mechanical

More information

INSTRUCTION MANUAL (ATEX / IECEx)

INSTRUCTION MANUAL (ATEX / IECEx) INSTRUCTION MANUAL (ATEX / IECEx) BExBGL2D LED BEACON For use in Flammable Gas and Dust Atmospheres BExBGL2D 1) Warnings DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE IS PRESENT DO NOT OPEN WHEN ENERGIZED POTENTIAL

More information

Operating instructions. AS-i Profibus gateway AC1411 / AC1412 7390884/00 04/2014

Operating instructions. AS-i Profibus gateway AC1411 / AC1412 7390884/00 04/2014 Operating instructions AS-i Profibus gateway AC1411 / AC1412 7390884/00 04/2014 Contents 1 Preliminary note 4 1.1 Notes on this document 4 1.2 Symbols used 4 2 Safety instructions 4 2.1 General 4 2.2 Installation

More information

OPERATION AND MAINTENANCE MANUAL

OPERATION AND MAINTENANCE MANUAL OM ELECTRIC ACTUATOR OPERATION AND MAINTENANCE MANUAL PERFORMANCE 12V / 24V Model Torque Speed Motor Motor Speed 12V DC/ AC 24V DC/ AC No. (Nm) (90 0 ) Power 12 V 24 V Run Start Lock Run Start Lock OM-A

More information

AGELKOM CAP04 Plasma and Oxy Fuel Torch height control for sheet metal cutting machines Height Sensor & Controller

AGELKOM CAP04 Plasma and Oxy Fuel Torch height control for sheet metal cutting machines Height Sensor & Controller 6 PIN INTERFACE CONNECTOR HEIGHT CONTROL KNOB CAP 04 CAPACITIVE HEIGHT CONTROLLER DOWN IN POSITION UP TOUCH CABLE FAULT AGELKOM CAP04 Plasma and Oxy Fuel Torch height control for sheet metal cutting machines

More information

SolarEdge. RS485 Expansion Kit Installation Guide. Version 1.0

SolarEdge. RS485 Expansion Kit Installation Guide. Version 1.0 SolarEdge RS485 Expansion Kit Installation Guide Version 1.0 Disclaimers Disclaimers Important Notice Copyright SolarEdge Inc. All rights reserved. No part of this document may be reproduced, stored in

More information

Wiring SIMATIC. Wiring. Overview 1. Wiring rules. Wiring the mains connection plug 3. Wiring the load current supply (PM) to the CPU 4

Wiring SIMATIC. Wiring. Overview 1. Wiring rules. Wiring the mains connection plug 3. Wiring the load current supply (PM) to the CPU 4 Overview 1 rules 2 SIMATIC Getting Started the mains connection plug 3 the load current supply (PM) to the CPU 4 Potential bridge circuits 5 the digital input module 6 the digital output module 7 front

More information

User's Guide. Model and Single Output Laboratory Grade Switching DC Power Supply

User's Guide. Model and Single Output Laboratory Grade Switching DC Power Supply User's Guide Model 382275 and 382276 Single Output Laboratory Grade Switching DC Power Supply Introduction Congratulations on your purchase of the Extech 382275 Single Output Laboratory Grade DC Power

More information

Elektromotoren und Gerätebau Barleben GmbH

Elektromotoren und Gerätebau Barleben GmbH Elektromotoren und Gerätebau Barleben GmbH OPERATING INSTRUCTIONS Transformer Protection Relay NM Series (Buchholz principle) Elektromotoren und Gerätebau Barleben GmbH Table of contents Page 1. Safety

More information

EFC 3600. Frequency converters

EFC 3600. Frequency converters 2 Bosch Rexroth AG Electric Drives and Controls Documentation Compact and complete: space saving side-by-side assembly, plug-in I/O terminals, with brake chopper and mains filter for ultra-simple installation

More information

T7560A,B,C Digital Wall Module

T7560A,B,C Digital Wall Module T7560A,B,C Digital Wall Module HONEYWELL EXCEL 5000 OPEN SYSTEM BEFORE INSTALLATION All wiring must comply with local electrical codes and ordinances or as specified on installation wiring diagrams. Digital

More information

Operating instructions Diffuse reflection sensor. OJ50xx 701396 / 01 07 / 2004

Operating instructions Diffuse reflection sensor. OJ50xx 701396 / 01 07 / 2004 Operating instructions Diffuse reflection sensor OJ50xx 7096 / 0 07 / 004 Contents Preliminary note. Symbols used Function and features Installation. Installation of the supplied mounting fixture 4 4 Electrical

More information

HP UPS R1500 Generation 3

HP UPS R1500 Generation 3 HP UPS R1500 Generation 3 Installation Instructions Part Number 650952-001 NOTE: The rating label on the device provides the class (A or B) of the equipment. Class B devices have a Federal Communications

More information

Battery Charger For Nickel Cadmium and Nickel-Metal Hydride Rechargeable Batteries Model PSN Series

Battery Charger For Nickel Cadmium and Nickel-Metal Hydride Rechargeable Batteries Model PSN Series Battery Charger For Nickel Cadmium and Nickel-Metal Hydride Rechargeable Batteries Model PSN Series Operating Instructions WARNING CONCERNING THE REMOVAL OF COVER: CAUTION: TO PREVENT THE RISK OF ELECTRIC

More information

Arc Protection Module REA 107. Operator s Manual

Arc Protection Module REA 107. Operator s Manual Arc Protection Module REA 107 1MRS752135-MUM Issued: 01.07.2002 Version: B/09.06.2005 Arc Protection Module REA 107 1. About this manual...5 1.1. Copyrights...5 1.2. Trademarks...5 1.3. Guarantee...5

More information

REMOTE MOUNT SOLENOID DRIVER (0-10 VDC Input Version)

REMOTE MOUNT SOLENOID DRIVER (0-10 VDC Input Version) REMOTE MOUNT SOLENOID DRIVER (0-10 VDC Input Version) Part No.: PCB Board - RSD-PCB-10V-x DIN Rail Mount RSD-DR-10V-x Packaged Driver (board installed in housing assembly) Available with no cable - RSD-SMB-10V-x-00

More information

CAUTION OPC-LM1-IL. Option Card for Encoder of Line Driver Output. Instruction Manual

CAUTION OPC-LM1-IL. Option Card for Encoder of Line Driver Output. Instruction Manual Instruction Manual OPC-LM1-IL Option Card for Encoder of Line Driver Output CAUTION Deliver this instruction manual without fail to those who actually operate the equipment. Read this operation manual

More information

System Monitoring Anemometer

System Monitoring Anemometer System Monitoring Anemometer Installation Guide Windsensor-IEN101010 98-0025210 Version 1.0 EN Table of Contents Table of Contents 1 Notes on this Guide............................... 4 1.1 Validity............................................

More information

IO-PT4. Component identification. User safety and equipment protection guidelines. Unitronics Industrial Automation 1

IO-PT4. Component identification. User safety and equipment protection guidelines. Unitronics Industrial Automation 1 IO-PT4 I/O Expansion Module 4 PT100 Inputs (-50 to 460 C) The IO-PT4 is an I/O Expansion Module that can be used in conjunction with specific Unitronics OPLC controllers. The module offers 4 PT100 inputs

More information

SINAMICS drives SINAMICS DCM. DC converters from 6 kw to 2500 kw for variable-speed direct-current drives. Load-balanced control application

SINAMICS drives SINAMICS DCM. DC converters from 6 kw to 2500 kw for variable-speed direct-current drives. Load-balanced control application SINAMICS DCM DC converters from 6 kw to 2500 kw for variable-speed direct-current drives Edition 01-12/2010 SINAMICS drives SINAMICS DCM Compact User Manual Legal information Warning notice system This

More information

OPERATING AND MAINTENANCE MANUAL FOR T1000 CONTROLLER

OPERATING AND MAINTENANCE MANUAL FOR T1000 CONTROLLER OPERATING AND MAINTENANCE MANUAL FOR T1000 CONTROLLER 2014 Edition CONTROL BOARD AND DISPLAY The control board supplies all the necessary functions for heater operation. These include control temperature,

More information

Operating Instructions Electronics module VEGADIF 65

Operating Instructions Electronics module VEGADIF 65 Operating Instructions Electronics module VEGADIF 65 Document ID: 36132 Differential pressure Contents Contents 1 About this document 1.1 Function.................................. 3 1.2 Target group..............................

More information

LAMBDA PROBE MODULE ML-2

LAMBDA PROBE MODULE ML-2 LAMBDA PROBE MODULE ML-2 page 2 Spis treści Spis treści 1 General information 4 1.1 Introduction 4 1.2 Contents 4 1.3 Safety precautions 5 1.4 Disposal of old equipment 6 2 Connecting to the system 7 2.1

More information

Induction Power Supplies

Induction Power Supplies Induction Power Supplies 3kW; 135 400kHz (Integral Heat Station) User s Guide Model 3-135/400-3 Model 3-135/400-3W Rev E 12/1/04 Table of Contents 1. SPECIFICATIONS AND FEATURES...3 1.1. Output...3 1.2.

More information

user manual Manual Part No

user manual Manual Part No user manual Manual Part No. 502408 Index 1.0 Introduction..........................2 This Manual...........................2 2.0 Safety Summary......................3 Terms in this Manual....................3

More information

RoHS. Shock / vibration resistant. Magnetic field proof. Many variants

RoHS. Shock / vibration resistant. Magnetic field proof. Many variants Sendix 5000 / 500 (Shaft / Hollow shaft) Push-Pull / RS4 ue to their sturdy bearing construction in Safety-ock esign, the Sendix 5000 and 500 offer high resistance against vibration and installation errors.

More information

ATV32HU75N4437 variable speed drive ATV32-7.5kW 400 V - 3P - Bluetooth built-in - w heat sink

ATV32HU75N4437 variable speed drive ATV32-7.5kW 400 V - 3P - Bluetooth built-in - w heat sink Characteristics variable speed drive ATV32-7.5kW 400 V - 3P - Bluetooth built-in - w heat sink Main Range of product Altivar 32 Product or component type Product destination Product specific application

More information

Mounting Instructions. Torque Transducer. A0329 3.2 en

Mounting Instructions. Torque Transducer. A0329 3.2 en Mounting Instructions Torque Transducer T5 T5 Contents 3 Page Safety instructions.............................................. 4 1 Measuring characteristics..................................... 7 2 Mounting.....................................................

More information

CPU 317-2 PN/DP: Configuring an ET. 200S as PROFINET IO device SIMATIC. PROFINET CPU 317-2 PN/DP: Configuring an ET 200S as PROFINET IO device

CPU 317-2 PN/DP: Configuring an ET. 200S as PROFINET IO device SIMATIC. PROFINET CPU 317-2 PN/DP: Configuring an ET 200S as PROFINET IO device CPU 317-2 PN/DP: Configuring an ET 200S as PROFINET IO device SIMATIC PROFINET CPU 317-2 PN/DP: Configuring an ET 200S as PROFINET IO device Introduction 1 Preparation 2 Learning units 3 Further Information

More information

D200-H4 LED DMX DRIVER 200 H4

D200-H4 LED DMX DRIVER 200 H4 User Guide D2-H4 LED DMX DRIVER 2 H4 Control Systems DRY Version 1. December 213 SPECIFICATION Electrical Power Voltage : 9-132VAC / 18-264VAC, 5-6Hz (Voltage switch in the internal power of the display)

More information

WAVE 1H HUMIDITY MODULE INSTRUCTION MANUAL

WAVE 1H HUMIDITY MODULE INSTRUCTION MANUAL WAVE 1H HUMIDITY MODULE INSTRUCTION MANUAL WAVE 1H is a microprocessorcontrolled humidity module for the sauna control unit WAVE 1. page 1 of 10 INSTRUCTION MANUAL 1.0.0 UNIT DESCRIPTION 2 1.1.0 GENERAL

More information

SIMATIC. ET 200M IM Interface Module. Introduction. Description 2. Technical specifications 3. Product Information 08/2007 A5E

SIMATIC. ET 200M IM Interface Module. Introduction. Description 2. Technical specifications 3. Product Information 08/2007 A5E SIMATIC ET 200M SIMATIC Introduction 1 Description 2 Technical specifications 3 ET 200M Product Information 08/2007 A5E01208335-01 Safety Guidelines Safety Guidelines This manual contains notices you have

More information

N20010, N NON-SPRING RETURN DAMPER ACTUATOR 20/34 Nm (177/300 lb-in) FOR MODULATING CONTROL SPECIFICATIONS GENERAL FEATURES PRODUCT DATA

N20010, N NON-SPRING RETURN DAMPER ACTUATOR 20/34 Nm (177/300 lb-in) FOR MODULATING CONTROL SPECIFICATIONS GENERAL FEATURES PRODUCT DATA GENERAL These direct-coupled damper actuators provide modulating control for: air dampers, VAV units, air handling units, ventilation flaps, louvers, and reliable control for air damper applications with

More information

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF Daker DK 1, 2, 3 kva Manuel d installation Installation manual Part. LE05334AC-07/13-01 GF Daker DK 1, 2, 3 kva Index 1 Introduction 24 2 Conditions of use 24 3 LCD Panel 25 4 Installation 28 5 UPS communicator

More information

Installation, Pre-Installation & Operation Manual. LED Pin Light. December 2012/ LED Pin Lighting

Installation, Pre-Installation & Operation Manual. LED Pin Light. December 2012/ LED Pin Lighting Installation, Pre-Installation & Operation Manual LED Pin Light December 2012/ 47-902714-000 1 LED Pin Light Installation, Pre-Installation & Operations Manual December 2012 by the Brunswick Bowling and

More information

Product Manual Ridder RW45 Motor Gearbox 1-phase (3-wire)

Product Manual Ridder RW45 Motor Gearbox 1-phase (3-wire) Product Manual Ridder RW45 Motor Gearbox 1-phase (3-wire) 265056EN - V03-2016.04 Lorentzstraat 36-38 3846 AX Harderwijk P.O. Box 360 3840 AJ Harderwijk the Netherlands T +31 (0)341 416 854 F +31 (0)341

More information

N20xxA, N34xxA NON-SPRING RETURN DIRECT-COUPLED DAMPER ACTUATORS FOR FLOATING AND 2-POSITION CONTROL

N20xxA, N34xxA NON-SPRING RETURN DIRECT-COUPLED DAMPER ACTUATORS FOR FLOATING AND 2-POSITION CONTROL N2xxA, N34xxA NON-SPRING RETURN DIRECT-COUPLED DAMPER ACTUATORS FOR FLOATING AND 2-POSITION CONTROL SPECIFICATIONS Supply voltage N224A / N3424A N223A / N3423A PRODUCT DATA 24 Vac 15%, 5/6 Hz 23 Vac 15%,

More information

L5354 ControlNet Communications Interface

L5354 ControlNet Communications Interface L5354 ControlNet Communications Interface Technical Manual HA470733 Issue 2 Copyright SSD Drives Inc 2005 All rights strictly reserved. No part of this document may be stored in a retrieval system, or

More information

FLUORESCENT UV- RING LIGHT OPERATING INSTRUCTION

FLUORESCENT UV- RING LIGHT OPERATING INSTRUCTION FLUORESCENT UV- RING LIGHT OPERATING INSTRUCTION Caution! UV-radiation of this device is in the range of UV-A (320-400 nm). Direct exposure to eyes shall therefore be avoided. UV protection glasses shall

More information

Electronic Solar Switch

Electronic Solar Switch Electronic Solar Switch DC circuit breaker for SMA inverters User manual EN ESS-BEN074812 TBE-ESS Table of Contents Table of Contents 1 Notes on this Manual...................... 5 1. 1 Validity.................................

More information

Arc Protection Module REA 103. Operator s Manual

Arc Protection Module REA 103. Operator s Manual Arc Protection Module REA 103 1MRS751004-MUM Issued: 05.11.2003 Version: C/09.06.2005 Arc Protection Module REA 103 1. About this manual...5 1.1. Copyrights...5 1.2. Trademarks...5 1.3. Guarantee...5

More information

Operating instructions

Operating instructions ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-74673 Mulfingen Phone +49 (0) 7938 81-0 Fax +49 (0) 7938 81-110 info1@de.ebmpapst.com www.ebmpapst.com CONTENTS 1. SAFETY REGULATIONS AND S 1.1 Levels of hazard

More information

Installation Method 1: Lays Into the Ceiling Grid. Package Contents

Installation Method 1: Lays Into the Ceiling Grid. Package Contents 5731 Benjamin Center Drive Tampa, Florida 33634 Phone:813.349.1900 Fax:813.349.1907 Version: A Release Date: 2013-07-24 READ THIS MANUAL CAREFULLY AND KEEP IT ACCESSIBLE FOR FURTHER REFERENCE! USE AS DIRECTED:

More information

CoolWave r 2 Phase Control Board and Cable Replacement Kits

CoolWave r 2 Phase Control Board and Cable Replacement Kits Instruction Sheet P/N 1102452A CoolWave r 2 Phase Control Board and Cable Replacement Kits Two kits are available to replace the CoolWave 2 phase control board: S S Phase Control Board and Cable Kit (required

More information

EZ-GO 1206 MX to Curtis 1268 Conversion

EZ-GO 1206 MX to Curtis 1268 Conversion EZ-GO 1206 MX to Curtis 1268 Conversion Installation Instructions 62-12685502EKPI (EZGO Instructions) Rev03 10/24/12 Page 1 of 6 EZ-GO 1206 MX to Curtis 1268 Conversion Installation Instructions Before

More information

PowerFlex 700S and 700H Frame 12 DC Bus Connector Kit

PowerFlex 700S and 700H Frame 12 DC Bus Connector Kit PowerFlex 700S and 700H Frame 12 DC Bus Connector Kit Installation Instructions This document provides instructions for the installation of a DC bus connector kit for PowerFlex 700S and 700H frame 12 drives

More information

Operating Instructions

Operating Instructions MAKING MODERN LIVING POSSIBLE Operating Instructions VLT Frequency Converters - Safe Torque Off www.danfoss.com/drives Contents Contents 1 Introduction 2 1.1 Purpose of the Manual 2 1.2 Additional Resources

More information

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

Automation System TROVIS 6400 TROVIS 6493 Compact Controller Automation System TROVIS 6400 TROVIS 6493 Compact Controller For panel mounting (front frame 48 x 96 mm/1.89 x 3.78 inch) Application Digital controller to automate industrial and process plants for general

More information

Documentation for. KL2602 and KL2622. Two-channel Relay Output Terminals for 230 V AC / 30 V DC. Version: 1.4 Date: 2013-03-20

Documentation for. KL2602 and KL2622. Two-channel Relay Output Terminals for 230 V AC / 30 V DC. Version: 1.4 Date: 2013-03-20 Documentation for KL2602 and KL2622 Two-channel Relay Output Terminals for 230 V AC / 30 V DC Version: 1.4 Date: 2013-03-20 Table of contents Table of contents 1 Foreword 1 1.1 Notes on the documentation

More information

2100, 2200, 2300, 4100, 6200, MPB Series Side Mount Drive Package for Standard Load 90 Industrial Gearmotors

2100, 2200, 2300, 4100, 6200, MPB Series Side Mount Drive Package for Standard Load 90 Industrial Gearmotors 00, 00, 300, 400, 600, MPB Series Side Mount Drive Package for Standard Load 90 Industrial Gearmotors Installation, Maintenance & Parts Manual Featuring: Technology DORNER MFG. CORP. INSIDE THE USA OUTSIDE

More information

About this Manual. Support for Your Product

About this Manual. Support for Your Product About this Manual We ve added this manual to the Agilent website in an effort to help you support your product. This manual is the best copy we could find; it may be incomplete or contain dated information.

More information

APS-Arduino Shield. Evaluation Board for the APS Stepper Motor Power Stage. Manual 2120-A002 EN ID

APS-Arduino Shield. Evaluation Board for the APS Stepper Motor Power Stage. Manual 2120-A002 EN ID APS-Arduino Shield Evaluation Board for the APS Stepper Motor Power Stage ID 10016767 Manual 2120-A002 EN phytron APS-Arduino Shield Evaluation Board for the APS Stepper Motor Power Stage TRANSLATION OF

More information

IFC 100. Quick Start. Signal converter for electromagnetic flowmeters

IFC 100. Quick Start. Signal converter for electromagnetic flowmeters Quick Start Signal converter for electromagnetic flowmeters General safety notes You can find the newest and/or additional information on the CD-ROM provided, in the handbook, the datasheet, special manuals,

More information

I nstallation. M100Q Series Proportional Actuator with R81Q Controller Board for Thermistor Sensor Applications. Tools Needed.

I nstallation. M100Q Series Proportional Actuator with R81Q Controller Board for Thermistor Sensor Applications. Tools Needed. FANs 268.1, 1628.3 Installation Bulletin M100Q Issue Date 1099 M100Q Series Proportional Actuator with R81Q Controller Board for Thermistor Sensor Applications I nstallation Parts Included M110QGA-1 and

More information

Analog Servo Drive 25A8

Analog Servo Drive 25A8 Description Power Range NOTE: This product has been replaced by the AxCent family of servo drives. Please visit our website at www.a-m-c.com or contact us for replacement model information and retrofit

More information

Operating Instructions Drill rig DRU160

Operating Instructions Drill rig DRU160 Operating Instructions Drill rig DRU160 Index 000 / 001 Original operating instructions 10988825 en / 20.10.2009 Congratulations! With a Hydrostress unit from TYROLIT you have chosen a tried and tested

More information

Ambient Temperature Sensor TEMPSENSOR-AMBIENT

Ambient Temperature Sensor TEMPSENSOR-AMBIENT Ambient Temperature Sensor TEMPSENSOR-AMBIENT Installation Guide TempsensorAmb-IEN110610 98-0042210 Version 1.0 EN SMA Solar Technology AG Table of Contents Table of Contents 1 Notes on this Guide...............................

More information

Teleservice via RS232 interface XC100/XC200

Teleservice via RS232 interface XC100/XC200 User Manual 10/10 MN0500005Z-EN replaces 07/04 AWB74-1490GB Teleservice via RS interface XC100/XC00 All brand and product names are trademarks or registered trademarks of the owner concerned. Emergency

More information

BNI IOL-709-000-K006 BNI IOL-710-000-K006. IO-Link Sensor-Hub analog User s Guide

BNI IOL-709-000-K006 BNI IOL-710-000-K006. IO-Link Sensor-Hub analog User s Guide BNI IOL-709-000-K006 BNI IOL-710-000-K006 IO-Link Sensor-Hub analog User s Guide Inhalt 1 Notes to the user 2 1.1 About this guide 2 1.2 Structure of the guide 2 1.3 Typographical conventions 2 Enumerations

More information

DALI RC BASIC SO. Control unit Operating instructions

DALI RC BASIC SO. Control unit Operating instructions DALI RC BASIC SO Control unit Operating instructions Contents Safety... 4 General instructions 4 Safety instructions 4 Description... 5 Purpose and application 5 Function 5 Light control 5 Brightness

More information

Waveguide Access Point WGA631. Product Guide

Waveguide Access Point WGA631. Product Guide Waveguide Access Point Product Guide Waveguide Access Point Contents 1. Description............................ 3 2. Application............................ 3 3. Technical data... 4 4. Physical interfaces......................

More information

LED-256D RGB. User Manual. Innovation, Quality, Performance. Professional Entertainment Technology. EC - Declaration of Conformity

LED-256D RGB. User Manual. Innovation, Quality, Performance. Professional Entertainment Technology. EC - Declaration of Conformity EC - Declaration of Conformity We declare that our products (lighting equipments) comply with the following LED-256D RGB specification and bears CE mark in accordance with the provision of the Electromagnetic

More information

PRO370D 65A Mbus MID DIN rail three phase four wire energy meter. User manual Version 1.03

PRO370D 65A Mbus MID DIN rail three phase four wire energy meter. User manual Version 1.03 PRO370D 65A Mbus MID DIN rail three phase four wire energy meter User manual Version 1.03 1 Safety instructions... 3 2 Foreword... 4 3 CE certificates... 5 4 MID certificate... 7 5 Performance criteria...

More information

ServoOne. Specification. Option 2 - Technology. x 11. x 8 X 8. x 10. x 9. x 7. x 6 TTL Encoder / TTL Encoder simulation

ServoOne. Specification. Option 2 - Technology. x 11. x 8 X 8. x 10. x 9. x 7. x 6 TTL Encoder / TTL Encoder simulation x - + - + x L L L AC SO 4-45 A DC SO 4- A ServoOne Specification x 9 - + - + x 7 x 8 X 8 Option - Technology x 6 TTL Encoder / TTL Encoder simulation Specification ServoOne Specification Option - Technology

More information

Altivar 61 Variable Speed Drive PID Function Setup

Altivar 61 Variable Speed Drive PID Function Setup Data Bulletin 8000DB0701 10/2009 Raleigh, NC, USA Altivar 61 Variable Speed Drive PID Function Setup Retain for future use. Overview This bulletin covers only the configuration of the parameters required

More information

IntelliComm Communication Center (For use with the IntelliFlo and IntelliPro pumps) Installation Guide

IntelliComm Communication Center (For use with the IntelliFlo and IntelliPro pumps) Installation Guide IntelliComm Communication Center (For use with the IntelliFlo and IntelliPro pumps) Installation Guide IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS Technical Support

More information

CP-8301-xxx Series. Application. Features. Applicable Literature. 1 to 15 Vdc Input Electronic Actuator Drive General Instructions

CP-8301-xxx Series. Application. Features. Applicable Literature. 1 to 15 Vdc Input Electronic Actuator Drive General Instructions TAC 54 Clifford Avenue P. O. Box 940 Loves Park, IL 6-940 www.tac.com CP-80-xxx Series to 5 Vdc Input Electronic General Instructions Application The CP-80-xxx Series electronic actuator drive is designed

More information

Series 7500 Torque Sensor

Series 7500 Torque Sensor Properties PTO (Power Take-Off) shaft with integrated torque and angle measurement Non-contact measurement system, high robustness Plug & Play solution, no additional electronics required Performance Measurement

More information

E/P Regulator (DeviceNet TM type) ITV1000/2000/3000/2090-DE* Series

E/P Regulator (DeviceNet TM type) ITV1000/2000/3000/2090-DE* Series Doc. No. ITV2-OM00095-B P R O D U C T N A M E E/P Regulator (DeviceNet TM type) MODEL/ Series/ Product Number ITV1000/2000/3000/2090-DE* Series Install and operate the product only after reading the Operation

More information

English. Fitting Instructions: Bonneville, Bonneville T100 and Thruxton A9600469 and A960075. 1 of 7. Parts Supplied:

English. Fitting Instructions: Bonneville, Bonneville T100 and Thruxton A9600469 and A960075. 1 of 7. Parts Supplied: English Fitting Instructions: Bonneville, Bonneville T00 and Thruxton A9600469 and A960075 Thank you for choosing this Triumph genuine accessory kit. This accessory kit is the product of Triumph's use

More information

Air damper actuators

Air damper actuators 4 634 OpenAir TM Air damper actuators GDB...1 GLB...1 Rotary version, / AC 230 V Electronic motor driven actuators for three-position and modulating control Nominal torque 5 Nm (GDB), 10 Nm (GLB) Mechanically

More information