MANUAL MOTOR STARTERS. Ex9SN 2014 NOARK Electric
|
|
- Ferdinand McCormick
- 7 years ago
- Views:
Transcription
1 MANUAL MOTOR STARTERS Ex9SN 2014 NOARK Electric
2 Ex9SN Product Overview Features Manual motor starters are electromechanical protection devices for the main circuit. They are used mainly to switch motors manually ON/OFF and protect them fuse less against short circuit and lossphase. Nonefuss protection with a manual motor starter saves costs, space and ensures a quick reaction under shortcircuit condition, by switching off the motor within milliseconds. Manual motor starter combinations are setup together with contactors and overload relays. Available with enclosed coils for protection against particle contamination Shortcircuit protection Disconnect function P Overload protection P Lossphase protection Suitable for three and singlephase application Tripfree mechanism Clear switch position indication ON/OFF/TRIP Lockable handle F All Rights Reserved F153
3 Ex9SN National and International Standards Certifications IEC/EN and CE Approved UL 508 Listed, File Number E467185, UL and A CSA Certified 22.2 No. 14 RoHS Compliant F NOARK Electric
4 Ex9SN Product Selection Guide Label Adjustable Current Range 2 Rated Current 3 Test Button 4 Brand 5 Product Selection 6 OFF/ON Push Buttons or Rotary Handle with Padlock F Product Selection Guide Ex9SN 25 A 0.16 A NOARK Ex9SN Series Frame Size Style Rated Current 25: 25 A A: Rotary Handle B: Pushbutton 0.16A: 0.1~0.16 A 0.25A: 0.16~0.25 A 0.4A: 0.25~0.4 A 0.63A: 0.4~0.63 A 1A: 0.63~1 A 1.6A: 1~1.6 A 2.5A: 1.6~2.5 A 4A: 2.5~4 A 6.3A: 4~6.3 A 10A: 6.3~10 A 14A: 9~14 A 18A: 13~18 A 23A: 17~23 A 25A: 20~25 A All Rights Reserved F155
5 Ex9SN 25 A Rotary Handle and Pushbutton Certifications IEC/EN Rated Current Amp (MinMax) Rotary Handle 25 A Pushbutton Product Part Number Product Part Number 0.1~0.16 Ex9SN25A0.16A Ex9SN25B0.16A ~0.25 Ex9SN25A0.25A Ex9SN25B0.25A ~0.4 Ex9SN25A0.4A Ex9SN25B0.4A ~0.63 Ex9SN25A0.63A Ex9SN25B0.63A ~1 Ex9SN25A1A Ex9SN25B1A ~1.6 Ex9SN25A1.6A Ex9SN25B1.6A ~2.5 Ex9SN25A2.5A Ex9SN25B2.5A ~4 Ex9SN25A4A Ex9SN25B4A ~6.3 Ex9SN25A6.3A Ex9SN25B6.3A ~10 Ex9SN25A10A Ex9SN25B10A ~14 Ex9SN25A14A Ex9SN25B14A ~18 Ex9SN25A18A Ex9SN25B18A ~23 Ex9SN25A23A Ex9SN25B23A ~25 Ex9SN25A25A Ex9SN25B25A Specifications...F157 to 158 Dimensions...F159 Wiring Diagram...F160 Mounting Positions...F161 Accessories...F162 to 165 F NOARK Electric
6 Ex9SN Specifications Operating Conditions Tripping Class Temperature Class 10 & 10 A 13 F to 158 F (25 C to +70 C) Average temperature in 24 hours not exceed 95 F (35 C) Altitude Not to exceed 6,562 ft (2,000 m) Air Conditions Pollution Grade Release Grade Rated Operational Frequency Mounting Conditions Rated Insulation Voltage Ui (V) At mounting site, relative humidity not exceed 50% at the max temperature of 104 F (+40 C), higher relative humidity is allowable under lower temperature Grade III 10 A (SN25) 50/60 Hz The inclination between the mounting plane and the vertical plane shall not exceed 5. The product shall be installed and operated at a place without obvious shake, impact and vibration. IEC 690 V, UL/CSA 600 V Rated Operational Voltage Ue (V) 230/340, 400/415, 440, 50, 690 Rated Impulse Withstand Voltage Uimp (V) 8,000 Overload Protection Properties Series Number Multiple of Setting Current Initial Status Time Expected Results Cold Status t 2h NonTripping Ambient Temperature Heat Status (right after test 1) Tripping Class Cold Status Tripping Class Phase Failure Protection Properties Series Number Multiple of Setting Current Any 2 Phase The Other Phase t<2h 10 A t<2 min. 10 t<4 min. 10 A 2s<t 10s 10 4s<t 10s Tripping 68 F to ±35.6 F (+20 C to ±2 C) Initial Status Time Expected Results Ambient Temperature F Cold Status t 2h NonTripping Temperature Compensation Properties Heat Status (right after test 1) t<2h Tripping 68 F to ±35.6 F (+20 C to ±2 C) Series Number Multiple of Setting Current Initial Status Time Expected Results Ambient Temperature Cold Status t 2h NonTripping Heat Status (right after test 1) t<2h Tripping Cold Status t 2h NonTripping Heat Status (right after test 1) t<2h Tripping 104 F to ±35.6 F (+40 C to ±2 C) 23 F to ±35.6 F (5 C to ±2 C) All Rights Reserved F157
7 Ex9SN Specifications Setting Current Range (A) 0.1~ ~ ~ ~ ~ 1 1~ ~ ~4 4~ ~ 10 9~14 13~18 17~23 20~25 Rated Current of Release UL Ratings SinglePhase (HP) ThreePhase (HP) IEC Ratings 400/415 Vac 690 Vac 120 Vac 1/8 1/4 1/2 3/ Vac 1/10 1/6 1/3 1/ Vac 1/ Vac /2 3/ Vac Icu (ka) Ics % Icu Icu (ka) 3 Ics % Icu 75 Rated Ultimate ShortCircuit Breaking Capacity Icu (ka) Rated Service ShortCircuit Breaking Capacity Ics (ka) Arcing Distance Standard Rated Power of Three Phase Motor (kw) 230/240 V /415 V V /500 V /690 V /240 V /415 V V /500 V /690 V /240 V Current Setting Value of Instantaneous Electrmagnetic Release Ir (A) Current Rating of FuseLink of Back Up Fuse, Which is Only Needed in Case of Icc>Icu (Icc: Prospective ShortCircuit Breaking Current) H: Fuse is not Required Degree of Protection 1.57 in (40 mm) V V V V /690 V /240 V am A 80 H gi/gg A 100 H am A /415 V gi/gg A H am A V H gi/gg A V 690 V am A 50 gi/gg A 63 am A gi/gg A IP2L0 F NOARK Electric
8 Ex9SN Dimensions Ex9SN25A Unit: in. [mm] 1.83±0.013 [46.5±0.32] 1.77±0.013 [45±0.32] 1.21±0.012 [30.8±0.30] 0.31±0.009 [8±0.24] 1.74±0.031 [44.2±0.8] 3.17±0.035 [80.5±0.9] 3.74±0.035 [94.9±0.9] 1.57 [40] 1.40± [40] [35±0.28] 1.75±0.031 [44.5±0.8] 3.50±0.028 [89±0.7] 3.60±0.028 [91.3±0.7] Ex9SN25B Unit: in. [mm] F 1.83±0.013 [46.5±0.32] 1.77±0.013 [45±0.32] 1.40±0.011 [35±0.28] 3.60±0.028 [91.3±0.7] 0.64±0.012 [16.3±0.29] 0.58±0.022 [14.8±0.55] 0.31±0.009 [8±0.24] 1.74±0.031 [44.2±0.8] 2.60±0.037 [66±0.95] 1.75±0.031 [44.5±0.8] All Rights Reserved F159
9 Ex9SN Wiring Diagram Ex9SN25A/B U V U V W 2T1 4T2 6T3 2T1 4T2 6T3 2T1 4T2 6T3 1L1 3L2 5L3 1L1 3L2 5L3 1L1 3L2 5L3 L N M U V W M M Operating principle diagram of starter Principle connection diagram of starters and contactors Principle connection diagram of singlephase or DC motor F NOARK Electric
10 Ex9SN Accessories: Auxiliary Contact and Enclosure ASN A 11 Description Manual Motor Starter Accessory Type A: Auxiliary Contact Side Mount B: Auxiliary Contact Front Mount F: Auxiliary Contact with Fault Signal Contact Auxiliary Contact 11: 1NO+1NC 20: 2NO 1001: 1NO (Fault)+ 1NC (Auxiliary) 0101: 1NC (Fault)+ 1NC (Auxiliary) ASNA ASNB 1010: 1NO (Fault)+ 1NO (Auxiliary) 0110: 1NC (Fault)+ 1NO (Auxiliary) Accessory Description Type Product Part Number ASNA Side Mount ASNA ASNB Front Mount ASNB Auxiliary Contact ASNF ASNF Fault Signal Contact ASNF ASNF F ASNF Specifications... F Dimensions... F165 ASN EA Description Manual Motor Starter Accessory Type EA: Enclosure with Actuating Diaphragm ASNEA EB: Enclosure with Emergency Stop Pushbutton ASNEB Accessory Description Product Part Number ASNEA Enclosure ASNEB Specifications... F Dimensions... F166 All Rights Reserved F161
11 Ex9SN Accessories: Shunt Trip and UnderVoltage Release ASN T A Description Manual Motor Starter Accessory Type T: Shunt Trip Release Rated Voltage A: 110~115 Vac 50 Hz 127 V 60 Hz B: 220~240 Vac 60 Hz C: 380~400 Vac 50 Hz 440 V 60 Hz D: 380~400 Vac 60 Hz Specifications... F Dimensions... F165 Accessory Description Product Part Number Shunt Trip Release (Side Mount) ASNTA ASNTB ASNTC ASNTD ASN UV A Description Manual Motor Starter Accessory Type UV: UnderVoltage Release Rated Voltage A: 110~115 Vac 50 Hz 127 V 60 Hz B: 220~240 Vac 60 Hz C: 380~400 Vac 50 Hz 440 V 60 Hz D: 380~400 Vac 60 Hz Specifications... F Dimensions... F165 Accessory Description Product Part Number Under Voltage Release (Side Mount) ASNUVA ASNUVB ASNUVC ASNUVD F NOARK Electric
12 Ex9SN Accessory Specifications UL File Number UL Ratings Side Mount Auxiliary Contact Front Mount Electrical Contact Type B600 D300 Fault Signal Contact Actuating Diaphragm Enclosure Emergency Stop Pushbutton Shunt Trip Release Under Voltage Release ASNA ASNB ASNF ASNEA ASNEB ASNT ASNUV Fault: D300 Auxiliary: B600 E Rated Insulation Voltage Ui (V) Voltage Range of Operation 35~70% Ue 70~110% Ue Ue Max (V) Conventional Heating Current Ith (A) AC Vac 240 V 120 Vac 240 V Fault: 240 Auxiliary: 690 Fault: 2.5 Auxiliary: 6 Fault: 720 Vac/240 V Auxiliary: 720 Vac/240 V IEC File Number IEC/EN IEC/EN IEC Ratings PickUp Voltage (Un) 0.7~ ~1.1 DropOff Voltage (Un) 0.75~ ~0.35 IP Class IP 55 IP 55 F All Rights Reserved F163
13 Ex9SN Accessory Specifications Side Mount Auxiliary Contact Front Mount Fault Signal Contact ASNA ASNB ASNF Utilization Category AC15 AC14 Rated Operational Current Ie (A) Normal Operational Power P (W) 24 Vac Vac /127 Vac /240 Vac /415 Vac Vac Vac Vac 0.60 DC13 24 Vdc Vdc Vdc Vdc Vdc 0.50 AC15 24 Vac Vac /127 Vac /240 Vac /415 Vac Vac Vac Vac 400 DC13 24 Vdc Vdc Vdc Vdc Vdc 120 Operational Features (Times) 1, Auxiliary Contact Fault Signal Contact ASNF Utilization Category AC14 AC15 DC13 Connection I/Ie 6 10 U/Ue Cos ø or t Pe I/Ie Disconnection U/Ue 1.10 Cos ø or Pe t 0.95 Number of On/Off Operation Cycles and Operation Frequency Number of Operation Cycles Number of Operation Cycles Per Minute On Power Time F NOARK Electric
14 Ex9SN Accessory Dimensions Manual Motor Starter with Accessories Unit: in. [mm] Auxilary Contact Side Mount Auxilary Contact Side Mount & Fault Signal Contact Shunt Trip Release & Under Voltage Release Auxilary Contact Side Mount Auxilary Contact Side Mount & Fault Signal Contact Shunt Trip Release & Under Voltage Release Auxilary Contact Front Mount Auxilary Contact Front Mount 0.38 [9.5] 0.43 [11] 0.38 [9.5] 0.43 [11] [9.3] [9.3] 3.19 [81.1] 0.71 [18] [9.3] [9.3] 3.19 [81.1] 0.71 [18] F All Rights Reserved F165
15 Ex9SN Accessory Dimensions ASNEA Enclosure with Actuating Diaphragm Unit: in. [mm] 0.21 [5.4] ø0.25 ø[6.3] 3.63 [92.2] 3.69 [93.8] 3.52 [89.3] 0.21 [5.4] 5.12 [130] 5.8 [147.6] ASNEB Enclosure with Emergency Stop Pushbutton Unit: in. [mm] 0.21 [5.4] ø0.25 [ø6.3] 3.63 [92.2] 5.99 [152.3] 3.52 [89.3] 0.21 [5.4] 5.12 [130] 5.8 [147.6] F NOARK Electric
16 F All Rights Reserved F167
17 NOARK Electric North America (626) Note: NOARK Electric reserves the right to make technical changes or modify the contents of this document without prior notice. With regard to purchase orders, the agreed particulars shall prevail. NOARK Electric does not accept any responsibility whatsoever for potential errors or possible lack of information in this document. NOARK Electric reserves all rights in this document and in the subject matter and illustrations contained therein. Any reproduction, disclosure to third parties or utilization of its contents in whole or in parts is forbidden without prior written consent of NOARK Electric NOARK Electric All Rights Reserved CCR201401NA
Electronic overload relay EF65, EF96 and EF146
Data sheet Electronic overload relay EF65, EF96 and EF146 Electronic overload relays offer reliable protection in case of overload and phase-failure. They are the alternative to thermal overload relays.
More informationElectronic overload relay EF19 and EF45
Data sheet Electronic overload relay EF19 and EF45 Electronic overload relays offer reliable protection in case of overload and phase-failure. They are the alternative to thermal overload relays. Motor
More informationManual motor starter MS116
Data sheet Manual motor starter MS116 Manual motor starters are electromechanical devices for motor and circuit protection. These devices offer local motor disconnect means, manual ON/ OFF control, and
More informationAF09-30-22-.. / AF09Z-30-22-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals
Technical Datasheet 1SBC101403D0201 24/03/11 AF09-30-22-.. / AF09Z-30-22-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals AF09(Z) contactors are used for controlling power circuits
More informationABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.
1SR 430 824 F9300 Features Monitoring of three-phase mains for phase sequence and failure Powered by the measuring circuit 2 c/o (SPDT) contacts 1 LED for status indication Approvals R: yellow LED - relay
More informationNF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals
Technical Datasheet 1SBC101433D0201 28/03/11 NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals NF(Z) contactor relays are used for switching auxiliary and control circuits.
More informationTechnicaldata General
Currenttransformer-operatedoverloadrelay,60-90A,1N/O+1N/C Partno. ZW7-90 Articleno. 002618 CatalogNo. XTOT090C3S Deliveryprogramme Product range ZW7 current transformer-operated overload relays Description
More informationThree-phase monitoring relay CM-PFE
Data sheet Three-phase monitoring relay CM-PFE The CM-PFE is a three-phase monitoring relay that monitors the phase parameter phase sequence and phase failure in three-phase mains. 2CDC 251 005 S0012 Characteristics
More informationSafety automation solutions
Operating principle, characteristics Preventa safety s types XPS AV,, For and switch monitoring Operating principle Safety s XPS AV, and are used for monitoring circuits conforming to standards EN/ISO
More informationLC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A - 220 V AC coil
Product data sheet Characteristics LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 -
More informationMolded Case Circuit Breaker Specifications Bulletin Number 140U-D
Technical Data Molded Case Circuit Breaker Specifications Bulletin Number 140U-D Topic Page Product Line Overview 2 Specifications 3 Trip Curves 4 Approximate Dimensions 6 Additional Resources These documents
More informationCircuit Breakers. Next Generation of Protection Capabilities
Circuit Breakers Next Generation of Protection Capabilities Circuit Breaker Offering Rockwell Automation offers a full line of Allen-Bradley circuit breakers and motor protection devices to help meet many
More informationElectronic timer CT-VBS.17+18 OFF-delayed without auxiliary voltage, for DC contactors Data sheet
Characteristics Single-function OFF-delay timer for DC contactors, without auxiliary voltage Width.5 mm CDC 5 6 F3 Approvals A culus E CCC CT-VBS a Circuit diagram b Marker label Marks a CE b C-Tick Order
More informationBulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller
Overview/Modes of Operation Bulletin 150 Smart Motor Controller The SMC-3 is a compact, simple to use, solid-state motor controller designed to operate 3-phase motors. It features a built-in overload relay
More informationManual Motor Starter MS 116 up to 16 A Technical Data
Manual Motor Starter MS 116 up to 16 A Technical Data Type MS 116 Standards: Major International IEC 60 947-4-1 / IEC 60 947-2 and European Standards EN 60 947-4-1 / EN 60 947-2 Approvals, Certificates
More informationBT300 HVAC Drives Conventional Bypass (C-Bypass) Options
BT300 HVAC Drives Conventional Bypass (C-Bypass) Options Description The BT300 Conventional Bypass is a companion package for the family of BT300 HVAC Drives. For information on the family of BT300 HVAC
More informationPSR The compact range Description
Description The PSR range is the most compact of all the ABB softstarter ranges, thereby making it possible to fit many devices into the same enclosure. The system concept with Manual Motor Starters provides
More informationTechnical catalogue. Modular DIN rail components Installation contactors
Technical catalogue Modular DIN rail components Installation contactors Installation Contactors Overview... ESB Installation Contactors 0 A / AC-/AC-7a ESB0...4 4 A / AC-/AC-7a ESB4...5 40 A / AC-/AC-7a
More informationEmergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN 60204-1, VDE 0113 Part 1
MainswitchSurfacemounting Partno. P3-63/I4/SVB Articleno. 207343 CatalogNo. SP3-063-I4CRQ IP65 Deliveryprogramme Product range Switch-disconnectors Basic function Main switches Maintenance switches Manual
More informationApplication Switchgear for industrial and commercial applications. U e V AC 230/400. 48 (per pole)
Overcurrentswitch,6A,2p,D-Char,AC Partno. FAZ-D6/2 Articleno. 278777 CatalogNo. FAZ-D6/2 Similar to illustration Deliveryprogramme Basic function Miniature circuit breakers Pole 2 pole Tripping characteristic
More informationLow voltage Direct Current Network. Compact NSX DC PV. Circuit breakers and switch disconnectors for solar application.
Low voltage Direct Current Network Compact NSX DC PV Circuit breakers and switch disconnectors for solar application Catalogue 2012 Compact NSX DC PV A complete DC offer for solar application from 80
More informationBimetallic Overload Relay Specifications
Technical Data Bimetallic Overload Relay Specifications Bulletin Number 193K, 193T1 Topic Page Product Overview 2 Standards compliance and Certifications 2 General Specifications 193K 3 Approximate Dimensions
More informationCatalog. Modular DIN rail components Installation contactors
Catalog Modular DIN rail components Installation contactors 0 CDC00C00 Installation contactors Benefits and features Overview Ordering details ESB installation contactors ESB0 ESB ESB0 ESB 7 EN installation
More informationVoltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages
Data sheet Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages The CM-ESS.2 is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of
More informationType: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated. Ordering information
Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated Ordering information Connection technique Description Description Rated operational current Screw terminals 3 pole AC
More informationElectronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact
Data sheet Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact The CT-AHD.12 is an electronic time relay with OFF-delay. It is from the CT-D range. With their MDRC profile and a width of only
More informationSUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original
SUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original A motor starter is a combination of devices to allow an induction motor to start, run and stop according
More informationType: DILM9 10(24VDC) Article No.: 276705
Type: DILM9 10(24VDC) Article No.: 276705 Ordering information Rated operational current AC 3 400 V I e A 9 Max. rating for three phase motors, 50 60 Hz AC 3 230 V Max. rating for three phase motors, 50
More informationRM17TE 183...528 V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC
Characteristics multifunction control relay RM17-TE - range 183..528 V AC Complementary Reset time Maximum switching voltage Minimum switching current Maximum switching current [Us] rated supply voltage
More informationRotary Disconnect Switch Specifications
Technical Data Rotary Disconnect Switch Specifications Bulletin Number 194R Topic Page Product Line Overview 2 General Specifications Fuse Description 12 Approximate Dimensions 14 Additional Resources
More informationPRODUCT GUIDE. SL Medium Voltage IEC Vacuum Contactors
PRODUCT GUIDE SL Medium Voltage IEC Vacuum Contactors Table of Contents 1 Overview Introduction....................................................2 Features........................................................2
More informationDead Tank Circuit Breaker 72PM40-C Proven reliability through common platforms
Dead Tank Circuit Breaker 72PM40-C Proven reliability through common platforms ABB innovations for changing demands ABB (www.abb.com) is a leader in power and automation technologies that enables utility
More informationR.C.C.B. s two-pole LEXIC
87045 LIMOGES Cedex Telephone : (+33) 05 55 06 87 87 Fax : (+ 33) 05 55 06 88 88 R.C.C.B. s two-pole LEXIC 089 06/09/10/11/12/15/16/17/18/ 27/28/29/30/35, CONTENTS PAGES 1. Electrical and mechanical characteristics...
More informationABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories
2CDC 251 014 F0t09 Features Monitoring of three-phase mains for grid feeding Type-tested in accordance with DIN V VDE V 0126-1-1: February 2006 Neutral conductor connection configurable Can also be used
More informationMini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protection
Technical Data Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protection Topic Page 1489-M Miniature Circuit Breakers 2 1492-SP Supplementary Protectors 15 1492-D Circuit Breakers 27 188 Regional
More informationVoltage monitoring relays CM-ESS.M For single-phase AC/DC voltages
Data sheet Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages The CM-ESS.M is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of
More informationMagnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...
Magnetic and Hydraulic-Magnetic Circuit Breaker 840-G2... Description Single, two and three pole magnetic circuit breakers with trip-free mechanism and push/pull on/off manual actuation. A choice of fast
More informationType: DILM32 10(24V50HZ) Article No.: 277247
Type: DILM32 10(24V50HZ) Article No.: 277247 Ordering information Rated operational current AC 3 400 V I e A 32 Max. rating for three phase motors, 50 60 Hz AC 3 230 V Max. rating for three phase motors,
More informationThree-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41
Data sheet Three-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41 The three-phase monitoring relays CM-PSS.x1 monitor the phase parameters phase sequence, phase failure as well as over- and undervoltage.
More informationPositive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous
Safety relay for monitoring E-STOP pushbuttons. Approvals Unit features Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous 1 auxiliary contact (N/C), instantaneous Safe separation of
More informationTmax MCCBs. Molded case circuit breakers. Tmax
Molded case circuit breakers Introduction ABB is once again demonstrating its commitment to new product development and its superiority in product performance. Never before has the industry seen such high
More informationType: EASY719 DC RC Article No.: 274119. Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description
Type: EASY719 DC RC Article.: 274119 Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC Description 12 digital inputs (4 inputs available as analog inputs) 6 relay outputs LCD display
More informationType: DILM50(230V50HZ,240V60HZ) Article No.: 277830
Type: DILM50(230V50HZ,240V60HZ) Article No.: 277830 Ordering information Rated operational current AC 3 400 V I e A 50 Max. rating for three phase motors, 50 60 Hz AC 3 230 V Max. rating for three phase
More informationZS6-S Screw Clamp Terminal Blocks Disconnect with blade
Technical Datasheet SNK646D00 Catalogue Page SNK646S00 ZS6-S Screw Clamp Terminal Blocks Disconnect with blade - Ease your disconnect operations with the disconnect blade operated by hand or with a screwdriver,
More informationRM4TG20 three-phase network control relay RM4-T - range 200..500 V
Characteristics three-phase network control relay RM4-T - range 200..500 V Complementary [Us] rated supply voltage Output contacts Setting accuracy of time delay Delay at power up Measuring cycle Marking
More informationVoltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages
Data sheet Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages The CM-ESS.2 is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of
More informationZS25 Screw Clamp Terminal Blocks Feed-through
Technical Datasheet SNK668D0 Catalogue Page SNK678S0 ZS Screw Clamp Terminal Blocks Feed-through Save space by connecting conductors up to mm² AWG in just mm 0.47 in spacing. SNK68V004 SNK004F0000 D CAD
More informationZS4-S-T Screw Clamp Terminal Blocks Disconnect with blade - with test socket
Technical Datasheet SNK64D00 Catalogue Page SNK64S00 ZS4-S-T Screw Clamp Terminal Blocks Disconnect with blade - with test socket - Ease your test operations with the built-in test sockets, - Screwdriver
More informationCurrent valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw
4 937 DESIO Current valve for AC 24 V pulse/pause control of electrical loads up to 30 kw SEA45.1 Use The current valve is used for the control of electric heating elements in heating, ventilation and
More informationZS4-SF1-T Screw Clamp Terminal Blocks For 5 x 20 and 5 x 25 fuses - with test socket
Technical Datasheet SNK636D00 Catalogue Page SNK636S00 ZS-SF-T Screw Clamp Terminal Blocks For x 0 and x fuses - with test socket - Protect your circuit with x and x0 fuse terminal blocks (fuse not supplied
More informationSeries 8146/5-V37 and Series 8150/5-V37
www.stahl.de > Clear assignment safe technology easy installation > Intelligent structure only one rotary actuator for frequency-controlled drives ) 20 ms leading auxiliary contact for safe motor disconnection
More informationPower Supplies 3. SDN-P DIN Rail Series
SDN-P DIN Rail Series The SDN DIN Rail power supplies provide industry leading performance. Sag Immunity, transient suppression and noise tolerant, the SDN series ensures compatibility in demanding applications.
More informationIEC style contactors - long electrical and mechanical life Complete range from mini-contactors to 630 Amp i n d u c t i ve AC3 ra t i n g s Wide
- long al and mechanical life Complete range from mini-contactors to 630 Amp i n d u c t i ve AC3 ra t i n g s Wide range coils +0% to -30% Finger safe terminals Four-pole versions available NO + NC and
More informationCatalog January. Heavy industrial power applications Motor contactors and starters
Catalog January Heavy industrial power applications Motor contactors and starters 2006 General contents 0 Heavy Industrial Power Applications Motor Contactors and Starters 1 Contactors and Starters, Type
More informationYour Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592. * see variants. Applications.
Safety Technique SAFEMASTER Emergency Stop Module BG 5924, IP 5924 Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592 BG 5924 IP 5924 Product Description
More informationBETA Switching. Switching Devices. 5TT5 8 Insta contactors, AC technology. Overview
BETA Switching Siemens AG 200 5TT5 Insta contactors, AC technology Overview The 5TT5 Insta contactors are equipped with an AC magnetic system and are ideal for use under harsh conditions. The auxiliary
More informationThermal-Magnetic Circuit Breaker 3120-...-M1-..
Thermal-Magnetic Circuit Breaker -...-M-.. Description Single or two pole rocker switch/thermal-magnetic circuit breaker with trip-free mechanism (S-type TM CBE to EN 34). The addition of a magnetic tripping
More informationTemperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)
Data sheet Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection) The temperature monitoring relays CM-TCS monitor overtemperature,
More information3RT1015-1BB41 CONTACTOR, AC-3 3 KW/400 V,
Automation Technology > Industrial Controls > Switching Devices > Contactors and Contactor Assemblies > Power Contactors for Switching Motors > Contactors SIRIUS 3RT10, 3-pole, 3... 250 kw 3RT1015-1BB41
More information8146/5 Series Breaker Panelboards
8146/5 Series Breaker Panelboards DISTRIBUTION BREAKER PANELBOARDS FOR HAZARDOUS & CORROSIVE ENVIRONMENTS Breaker Panels Features: Wide variety of Flameproof branch circuit breakers for Zone 1 & Division
More informationADS8 IP54 Direct-On-Line Starter Technical Focus. Replaces ADS7 Rated up to 9kW
ADS8 IP54 Direct-On-Line Starter Technical Focus Replaces ADS7 Rated up to 9kW New ADS8 Motor Starter The new ADS8 range of motor starters replaces the successful ADS7 range which was introduced 20 years
More informationEasy Multifunctional Safe
EMS Electronic motor starters www.eaton.eu Easy Multifunctional Safe EMS Multifaceted Performance with only 0 mm Eaton Moeller series products have always embodied quality and reliability in the machine
More informationGeneral information Circuit breakers for power distribution T1 T3
Circuit breakers for power distribution T1 T3 T1 T2 T3 T1 1P T1 T2 T3 UL 489 CSA C22.2 Frame size A 100 100 100 225 Number of poles Nr 1 3, 4 3, 4 3, 4 Rated voltage AC (50-60 Hz) V 277 600Y / 347V 480
More informationUncompromising safety and comfort The next generation of miniature circuit breakers MCB S 200/S 200 M
Uncompromising safety and comfort The next generation of miniature circuit breakers MCB S 200/S 200 M The details make the difference MCB S 200/S 200 M A range designed to ensure efficiency and protection
More informationBreaking and protection devices
Breaking and protection devices 05 POWER GUIDE 2009 / BOOK 05 INTRO The purpose of selecting a protection device is to perform two essential functions: to protect people and to protect trunking, while
More informationBulletin 1489 Circuit Breakers. Selection Guide
Bulletin 1489 s Selection Guide Bulletin 1489-A Overview/Description Bulletin 1489-A s Energy-limiting design protects downstream components better than conventional breakers during short circuits Field-mountable
More informationSystem pro M compact Miniature Circuit Breaker S 200/S 200 M
Data Sheet System pro M compact Miniature Circuit Breaker S 200/S 200 M 2CDC021023S0012 2CDC021038S0012 The miniature circuit breakers of the System pro M compact series S 200 and S 200 M provide state-of-the-art
More informationSafety technique. Emergency stop module BO 5988 safemaster
Safety technique Emergency stop module BO 5988 safemaster 0221562 Function diagram Pushbutton on Mains or emergencystop () K1 According to EC Directive for machines 98/37/EG According to IEC/E 60204-1
More informationNDQ5 Series. Automatic Transfer Switch. Shanghai Liangxin Electrical CO.,LTD
Shanghai Liangxin Electrical CO.,LTD Address: No. 668 Heng An Road, Pu Dong New District, Shanghai Zip: 200137 Tel: 86-21-5012789 Fax: 86-21-58675966 E-mail: client@sh-liangxin.com LINE 1 LINE 3 LINE 5
More informationRM35UA13MW. range 15..600 V. Main. Product or component type. Relay monitored parameters
Characteristics multifunction voltage control relay RM35-U - range 15..600 V Complementary Reset time Maximum switching voltage [Us] rated supply voltage Supply voltage limits Power consumption in W Main
More informationREVIEWED BY CAPITAL PROJECTS MANAGER (DAN REDDY) GENERAL MANAGER EQUIPMENT ENGINEERING & ASSET MANAGEMENT (HAMILTON NXUMALO)
SA Port Operations DOCUMENT TYPE: REFERENCE EEAM-Q-014 (ORIGINAL SPECIFICATION HE8.2.3 Ver5) REVISION 0 SPECIFICATION TITLE: SPECIFICATION FOR ELECTRICAL MOTORS AND GENERATORS PAGE 0 of 07 COMPILED BY
More informationMini Motor Contactor J7KNA Main contactor Accessories Approved Standards Standard Guide No (US,C) Ordering Information tage Model Number Legend gear
Mini Motor Contactor J7KNA ) Main contactor AC & DC operated Integrated auxiliary contacts Screw fixing and snap fitting (35 mm DIN-rail) Range from 4 to 5.5 (AC 3, 380/415V) 4 -main pole version (4 AC
More informationAutomatic Voltage Regulator User s Manual
Resp. dept. R&D We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. Copyright
More informationUncompromising safety and comfort Miniature Circuit Breaker SU 200 M for branch circuit protection per UL and CSA
Uncompromising safety and comfort Miniature Circuit Breaker SU 200 M for branch circuit protection per UL and CSA Miniature Circuit Breaker SU 200 M The next generation MCB for UL/CSA applications within
More informationPreventa Machine Safety Products
Preventa Machine Safety Products Catalog 2009 200 Supplement Safety Relay Modules 2 Contents Preventa safety relay modules Selection guide 2 Electrical Ratings 6 Types XPSAC and XPSAXE For Emergency stop
More informationMolded Case Circuit Breakers, Motor Protection Circuit Breakers, and Motor Circuit Protectors. Technical Data
Molded Case Circuit Breakers, Motor Protection Circuit Breakers, and Motor Circuit Protectors Technical Data Table of Contents Introduction... 4 Definitions... 5 Product Range... 8 Product Line Overview...11
More informationBulletin 150 SMC Flex Smart Motor Controller Specifications
Specifications Specifications Standard Features Optional Features Installation Setup Communications Power Wiring Control Wiring Keypad Software Starting and Stopping Modes Protection and Diagnostics Metering
More informationPlug and Socket Devices CES 63 A Series 8579
www.stahl.de > Switch socket / plug 63 A > Large switch handle with clear switch position indication padlockable in 0- and I-position > Low insertion and withdrawal forces through individually encapsulated
More information5SV Residual Current Protective Devices
s Siemens AG 2013 SENTRON 5SV Residual Current Protective Devices New portfolio for reliable personnel, material and fire protection Safe protection against residual currents Residual current protective
More informationSoft Starter. Product Description. Ordering Code. Type Selection. Selection Guide RSG D 40 16 E 0 VD00
Soft Starter Three Phase General Purpose Soft Starters Type RSGD Soft starting and soft-stopping of 3-phase squirrel cage motors 45mm wide IP20 housing Operational Voltage: RSGD40 (220-400V), RSGD60 (220-600V)
More informationControl Devices Catalogue. Control Devices. Preferred and Standard Products
Control Devices Catalogue Control Devices Preferred and Standard Products KOP.J Timer Electronic 22.5 mm Characteristics Mounting KOP.J 22.5 mm mono or multifunction high immunity to interference surface
More informationProducts and solutions for lifting systems
Products and solutions for lifting systems 100% electricity www.lovatoelectric.com Tra dition and Innovation LOVATO Electric S.p.A. - Bergamo - Italy Since 1922 The first LOVATO Electric headquarters founded
More informationGTEC transfer switch open transition
GTEC transfer switch open transition 40-1250 Amp Description The GTEC automatic transfer switch combines reliability and flexibility in a small, economical package for transferring loads between a utility
More informationPluggable interface relays CR-P Pcb relays
2CDC 293 034 F0004 1 2 4 3 Features 9 different supply s: DC versions: 12 V, 24 V, 48 V, 110 V AC versions: 24 V, 48 V, 110 V, 120 V, 230 V Output contacts: 1 c/o (16 A) or 2 c/o (8 A) Cadmium-free contact
More informationHow To Operate A Gec Transfer Switch Open Transition 40 2000 Amp Power Supply
GTEC Transfer switch open transition 40 2000 amp Description GTEC transfer switches combine reliability and flexibility in a small, economical package for transferring loads between a utility and a generator
More informationUnified requirements for systems with voltages above 1 kv up to 15 kv
(1991) (Rev.1 May 2001) (Rev.2 July 2003) (Rev.3 Feb 2015) Unified requirements for systems with voltages above 1 kv up to 15 kv 1. General 1.1 Field of application The following requirements apply to
More informationThermistor motor protection
Thermistor motor protection CM-E Range Thermistor motor protection Thermistor motor protection relays Benefits and advantages Selection table Operating principle and fields of application for thermistor
More informationD-Line Contactors, Overload Relays and Accessories
D-Line Contactors, Overload Relays and Accessories Class 850 CONTENTS Description......................................................Page General Information...............................................
More informationRY2 miniature industrial relays
6 RY2 Relays of general application For plug-in sockets, 35 mm rail mount acc. to PN-EN 60715 or on panel mounting Flat insert connectors - faston x 0,5 mm Recognitions, certifications, directives: RoHS,
More information7.2KV SL400 Withdrawable Vacuum Contactor-Fuse Combination Units
Automotive Powering business worldwide Aerospace Eaton delivers the hundreds of power distribution products that are answering the demands of today s fast changing world. We help our customers worldwide
More informationSURGE PROTECTIVE DEVICES
SURGE PROTECTIVE DEVICES 1. INTRODUCTION In order to ensure safety of people, protection of equipment and, to a certain extent, continuity of supply, insulation co-ordination aims at reducing the likelihood
More informationChrome DIN Rail Power Supply 12V 54W 1 Phase (Class II & NEC Class 2) / DRC-12V60W1AG
Highlights & Features Protection Class II, Double Isolation (No Earth connection is required) Universal AC input voltage and full power up to 55 C Power will not de-rate for the entire input voltage range
More informationSMS 4 / SMS 5 safety mat Product information
SMS 4 / SMS 5 safety mat Product information SMS 4 / SMS 5 safety mats Safety mats are used for the protection of man on machinery and plants with hazardous movements. Typical fields of application are,
More informationE-STOP relays, safety gate monitors
Unit features Safety features Gertebild ][Bildunterschrift Safety relay for monitoring E-STOP pushbuttons and safety gates. Approvals Gertemerkmale Positive-guided relay outputs: 3 safety contacts (N/O),
More information48 SERIES Relay interface modules 10 A
48 Relay interface modules 10 A 1 CO relay interface modules, mm wide Ideal interface for PLC and electronic systems Type 48.P3 1 CO 10 A s Type 48.31 1 CO 10 A s AC coils or DC sensitive coils Supply
More informationSentron Series Circuit Breakers
Sentron Series Circuit Breakers Siemens Sentron Series circuit breakers are available in nine frame sizes: ED, FD, JD, LD, LMD, MD, ND, PD, and RD. Sentron Series circuit breakers have a wide range of
More informationMicro Contactors. Micro Contactor Relays. Micro Contactors With Solder Pins. Coil voltages. Micro Reversing Contactor. Technical Data.
Micro Contactors Micro Contactor Relays 0 Micro Contactors Micro Contactors With Solder Pins Coil voltages Micro Reversing Contactor 3 Technical Data 4 Dimensions 8 9 Micro Contactor Relays 4pole C Operated
More information60 Series - General purpose relays 6-10 A. Features 60.12 60.13
Features 60.12 60.13 Plug-in mount 10 A General purpose relay 2 & 3 pole changeover contacts Cadmium Free contacts (preferred version) AC coils & DC coils UL Listing (certain relay/socket combinations)
More informationRelés e Contatores de Estado Sólido SIRIUS
Relés e Contatores de Estado Sólido SIRIUS Coletânea de dados técnicos ( product data sheet ) Agosto/212 SSR - 3RF21 22,5 mm Ponto Zero SSR - 3RF2 45 mm Ponto Zero SSR - 3RF22 45 mm Ponto Zero Trifásico
More informationMOTOR PROTECTIVE DEVICES
W MOTOR PROTECTIVE DEVICE, SERIES MP 206 BE400206 BE400306 Inherently stable without back-up fuseup to 4 A at 400 V AC, > 4 A main back-up fuse 100 A gl Thermal and magnetic release Terminal and accessory
More information