2 Company presentation Telergon is a leading company in the field of the switchgear engineering. Telergon designs and manufactures components and solutions for a wide variety of low voltage AC & DC applications. Telergon is present nowadays in many industrial and OEM sectors, being a worldwide resource in the field of DC switching technology for photovoltaics. This document introduces briefly the main standard products. Telergon has the know-how and R+D resources to customize products in accordance to customer requirements.

3 Suitable for use in accordance with NEC Art. 690 Index page 4 page 8 page 10 S5000DC DC Load break switches IEC 94-3 UL 98B & CAN/CSA C22.2 No 4-04 Size A Size A Size A Size A Size A DC Load break stacked switches. Multi-string 1000Vdc IEC 94-3 UL 98B & CAN/CSA C22.2 No 4-04 Size A Size A Size A Size A DC Load break switches 1500 Vdc IEC 94-3 Size A Size A Size A Size A (0 Vdc) IEC marking only page 14 TFV dc Load break compact switches 0/ IEC 94-3 UL in process 30 A

4 S5000 DC Load break switches For photovoltaic installations The S5000 series of DC switches utilize a spring loaded switching mechanism that quickly makes and breaks electrical contact. It is this design that permits switching of DC circuits under load. Applications: Solar Inverters Combiner boxes Battery charges A disconnecting device is required to be located at some point in the PV circuit. Load break switches are recommended for safety purposes, allowing personnel to work on the equipment without the risk of electrical shock. es also allow crews the ability to shut down zones/sections of the array for maintenance purposes, while leaving the rest of the field energize. 4

5 ø DC load break switches 0 Vdc Ie 100 A - 0 Vdc - DC21B IEC 94-3 Size 0 Poles 4 S5-014PB0 35,4 lbf.in / 4 Nm Approvals IEC 94-3 DS-EI01 DS-EN01 (2 pieces) Size 0 Front view Side view , max / min max. 105 / min. 15 UL 98B CAN/CSA C22.2 N , Top view Panel drilling handle UL in process ø ø0.1 4, dimensions: inches milimeters 5

6 DC LOAD BREAK SWITCHES Ie 250 A - Ie 400 A - UL98B & CAN/CSA C22.2 No IEC 94-3 UL98B & CAN/CSA C22.2 No IEC 94-3 S PR00U S PR00U Size 1 Size 2 Poles 4 Poles lbf.in / 18 Nm 212 lbf.in / 24 Nm DS-EI11 DS-EI21 DS-EN11 DS-EN21 Size 1 Size 2 Size 1 Size 2 Front view Side view Front view Side view M , max / min. 0.0 max. 150 / min ø0.25 6,5 M max / min. 0.0 max. 119 / min Top view Panel drilling handle Top view Panel drilling handle ø2.5 0 ø , ø ,5 ø1. dimensions: inches milimeters

7 Ie 00 A - UL98B & CAN/CSA C22.2 No. 4-04* IEC 94-3 Size 3 Poles 4 S PC00U 398 lbf.in / Nm Ie 1250 A - UL98B & CAN/CSA C22.2 No IEC 94-3 Size 4 Poles 4 S PS00U 48 lbf.in / 55 Nm DS-EI31 DS-EN31 DS-EI41 DS-EN41 Size 3 Size 4 Size 3 Size 4 * In process Front view Side view Front view Side view ø M max / min. 0.0 max. 108 / min ø max. 9.3 / min. 3.0 max. 238 / min. 8 Top view Panel drilling handle 3, Top view Panel drilling handle , , øm14 øm ø2.5 0 ø dimensions: inches milimeters ø ø1.

8 ø1. ø1. DC LOAD BREAK stacked SWITCHES - multi-string Ie 250 A - - DC21B IEC 94-3 Size 1 Poles 8 * S5M02508PR00U 159 lbf.in / 18 Nm DS-EI12 DS-EN12 (2 + 2 pieces) Size 1 Ie 400 A - - DC21B IEC 94-3 Size 2 Poles 8 * S5M06308PR00U 212 lbf.in / 24 Nm DS-EI22 DS-EN22 (2 + 2 pieces) Size 2 Size 1 Size 2 * Also available versions for 3 and 4 strings Front view Side view Front view Side view ø , ø M Top view Panel drilling handle Top view Panel drilling handle ø2.5 0 ø ,5 3, max / min. 3.4 max. 208 / min. 95 M max. 9.3 / min. 3.0 max. 238 / min dimensions: inches milimeters

9 Ie 00 A - - DC21B IEC 94-3 Size 3 Poles 8 * S5M12508PC00U 398 lbf.in / Nm DS-EI41 DS-EN41 (2 + 2 pieces) Size 3 Ie 1250 A - - DC21B IEC 94-3 Size 4 Poles 8 * S5M18008PS00U 48 lbf.in / 55 Nm DS-EI41 DS-EN41 (2 + 2 pieces) Size 4 Size 3 Size 4 * Also available versions for 3 and 4 strings Front view Side view Front view Side view ø M max. 9.3 / min. 3.0 max. 238 / min Top view Panel drilling handle Top view Panel drilling handle ,41 36 ø M max. 9.3 / min. 3.0 max. 238 / min ø2.5 0 ø ,5 ø ,5 ø1. dimensions: inches milimeters 9

10 ø1. ø1. DC LOAD BREAK SWITCHES 1500 Vdc Ie 250 A Vdc - DC21B IEC 94-3 Size 1 Poles S5M031544R Vdc 159 lbf.in / 18 Nm DS-EI12 Ie 400 A Vdc - DC21B IEC 94-3 Size 2 Poles S5M063044R Vdc 212 lbf.in / 24 Nm DS-EI22 DS-EN12 DS-EN22 (3 + 3 pieces) Size 1 (3 + 3 pieces) Size 2 Size 1 Size 2 Front view Side view Front view Side view ø , ø M Top view Panel drilling handle Top view Panel drilling handle ø2.5 0 ø ,5 3, max / min. 3.4 max. 208 / min. 95 M max. 9.3 / min. 3.0 max. 238 / min dimensions: inches milimeters

11 Ie 0 A Vdc - DC21B IEC 94-3 Size 3 Poles S5M125044C Vdc 398 lbf.in / Nm DS-EI41 DS-EN41 Ie 800 A Vdc - DC21B IEC 94-3 Size 4 Poles S5M180044S Vdc 48 lbf.in / 55 Nm DS-EI41 DS-EN41 (3 + 3 pieces) Size 3 (3 + 3 pieces) Size 4 Size 3 Size 4 Front view Side view Front view Side view ø M max. 9.3 / min. 3.0 max. 238 / min Top view Panel drilling handle Top view Panel drilling handle ø M max. 9.3 / min. 3.0 max. 238 / min ø2.5 0 ø ,5 ø ,5 ø1. dimensions: inches milimeters 11

12 DC LOAD BREAK SWITCHES Accessories (2 pieces) * Size 1 Size 2 Size 3 Size 4 Diagram Diagram Diagram Diagram A B A B A B A B TOP DS-CU180U DS-CU100U DS-CU280U DS-CU200U DS-CU380U DS-CU300U DS-CU480U DS-CU400U BOTtom DS-CU190U DS-CU11 DS-CU290U DS-CU21 DS-CU390U DS-CU31 DS-CU490U DS-CU41 Diagram Diagram Diagram Diagram C C C C TOP DS-CU180U DS-CU280U DS-CU380U DS-CU480U BOTtom DS-CU100U DS-CU200U DS-CU300U DS-CU400U * For the S5M series the shrouds can only be fitted in the frontal switch (2/ 3 pieces) S5M8P S5M4+4 Size 0 Size 1 Size 2 Size 3 Size 4 Diagram Diagram Diagram Diagram Diagram A - B A - B C A - B C A - B C A - B C S5 DS-PI05 DS-PI120U DS-PI130U DS-PI220U DS-PI230U DS-PI320U DS-PI330U DS-PI420U DS-PI430U Diagram Diagram Diagram Diagram A - B C - D A - B C - D A - B C - D A - B C - D TOP DS-PI120U DS-PI130U DS-PI220U DS-PI230U DS-PI320U DS-PI330U DS-PI420U DS-PI430U BOTtom DS-PI10U DS-PI1U DS-PI20U DS-PI2U DS-PI30U DS-PI3U DS-PI40U DS-PI4U Diagram Diagram Diagram Diagram C - D C - D C - D C - D TOP DS-PI130U DS-PI230U DS-PI330U DS-PI430U BOTtom DS-PI1U DS-PI2U DS-PI3U DS-PI4U L P Shaft extensions S5 L P Type 1 Type 2 DS-EP01 DS-EP12 DS-EP22 DS-EP31 DS-EP41 DS-EP02 DS-EP11 DS-EP21 DS-EP21 DS-EP42 Size (inches) (mm) (inches) (mm) Auxiliary contacts * D5LAU01 D5LAU02 S5 1NA + 1NC 2NA + 2NC Size * 16 A / 250 Vac (resistive load)

13 DC LOAD BREAK SWITCHES Accessories diagram + TOP A + BOTtom TOP S5 B + + BOTtom + + TOP C BOTtom diagram + FRONTAL SWITCH REAR SWITCH on frontal switch only TOP A BOTtom + S5M8P multi-string B + + TOP BOTtom C D + or - + or - TOP BOTtom S5M 4+4 diagram C + + or or D - - FRONTAL SWITCH REAR SWITCH on frontal switch only TOP BOTtom 13

14 TFV DC Load break compact switches For photovoltaic installations The TFV switch has knife-type contacts and very low resistive connections in order to achieve higher operational efficiency. Applications: Solar Inverters Combiner boxes Solar residential Its reliable switching mechanism allows quick making and breaking operations which are necessary to extinguish the electric arc in DC applications. Plastic components are halogen free and all TFV parts comply with the RoHS Directive. Thanks to its modular design, Telergon TFV is suitable for multistring (multi-mpp) switching including mixed AC/DC applications. The TFV compact switch is available in different options depending on mounting requirements. Its wide portfolio of accessories is compatible with other Telergon ranges. 14

15 DC LOAD BREAK COMPACT SWITCHES Techical data Technical features Ue max V 1000 Ie max A 50 Ui V 1500 Short-circuit making capacity Icm A 10 Rated short-time withstand current (1sec) Icw A 1000 Rated short-time withstand current (1 hour) A 62,5 Number of mechanical operations capacity Rigid copper cable in 2 / mm 2 2 x / 2 x 6 Flexible copper cable in 2 / mm 2 2 x / 2 x 6 Fork terminals in 2 / 10 mm 2 (consult) in 2 / mm 2 1 x / 1x10 Fork terminals in 2 / 16 mm 2 (consult) in 2 / mm 2 1 x / 1x16 Tightening torque (min-max) lbf.in / N m / 1,5-2 Operation torque lbf.in / N m 1. / 2 IEC tests performed at: TFV UL in process Codification Product codification Contacts (examples) T F V Series Voltage Contacts Certification Mounting type Handle type Handle colour Base type T F V 3 0 T F V 5 0 T F V 4 0 T F V 2 1 T F V 3 1 T F V Other configurations, please consult. 15

16 DC LOAD BREAK COMPACT SWITCHES 2 or 4 hole panel fixing directly on the switch External plate and handle Rear mounting with screws Diameter 22 hole quick fixing External plate and handle Rear mounting - quick fixing 0 Vdc Ue 0 Vdc Ue Ue Ue Ie 30 A Ie 30 A Contacts (0 Vdc) () Contacts (0 Vdc) () Chambers 3 / 5 Chambers 3 / x 1.96 in 50 x 50 mm 0 Vdc Black standard handle C0 CODE TFV0630UE1N1 CODE TFV1050UE1N x 1.96 in 50 x 50 mm 0 Vdc Black standard handle C0 CODE TFV0630UC1N1 CODE TFV1050UC1N x 1.96 in 50 x 50 mm Padlockable handle D04 C0 0 Vdc CODE TFV0630UE6N1 CODE TFV0630UE6RD Red / yellow CODE TFV1050UE6N1 CODE TFV1050UE6RD Red / yellow 2.42 x 2.42 in 61,5 x 61,5 mm Padlockable handle D04 C1 0 Vdc CODE TFV0630UCN0 CODE TFV0630UCR0 Red / yellow CODE TFV1050UCN0 CODE TFV1050UCR0 Red / yellow 2.42 x 2.42 in 61,5 x 61,5 mm Padlockable handle D04 C1 0 Vdc CODE TFV0630UEN0 CODE TFV0630UER0 Red / yellow CODE TFV1050UEN0 CODE TFV1050UER0 Red / yellow L max C L C Length Chambers 3 5 L ,3 3,43 8,3 Length Chambers 3 5 L , ,1 dimensions: inches milimeters

17 Base mounting on a DIN rail or 2 hole panel fixing Direct handle Base mounting - direct handle Base mounting on a DIN rail or 2 hole panel fixing External handle doorinterlock Base mounting - panel handle 0 Vdc Ue 0 Vdc Ue Ue Ue Ie 30 A Ie 30 A Contacts (0 Vdc) () Contacts (0 Vdc) () Chambers 4 / 6 Chambers 4 / x 1.96 in 50 x 50 mm 1.96 x 1.96 in 50 x 50 mm 1. 0 Vdc 0 Vdc ø Black standard handle C0 CODE TFV0630UHPN0 CODE TFV1050UHPN0 Padlockable handle D905 C0 CODE TFV0630UHRN0 CODE TFV1050UHRN0 L 1.96 x 1.96 in 50 x 50 mm 2.56 x 2.56 in 65 x 65 mm Padlockable handle & door interlock D04 C0 0 Vdc CODE TFV0630UF6N1 CODE TFV0630UF6RD Red / yellow CODE TFV1050UF6N1 CODE TFV1050UF6RD Red / yellow Black standard handle & door interlock D501 C1 0 Vdc CODE TFV0630UF1N1 CODE TFV1050UF1N , ,5 Length Chambers 4 6 L 3.05, , L x 2.42 in 61,5 x 61,5 mm max Padlockable handle D04 C1 0 Vdc CODE TFV0630UFN0 CODE TFV0630UFR0 Red / yellow CODE TFV1050UFN0 CODE TFV1050UFR0 Red / yellow L2 standard supply ,5 0,11 minimum 3 max acceptable , ,5 0,11 3 max max C0 C0 C0 C1 dimensions: inches milimeters standard supply ,6 minimum acceptable , Length Chambers 4 min max 6 min max L , ,5 L , ,5 L L ,

18 Other products SWITCH DISCONNECTORS Cam switches From 10 to 800A. Wide range of accessories and customized configurations. Load break switches From 40 to 6300A. 3P, 3P+N, 4P, 6P and 8P. Fusible switches From 32 to 800A. Available for DIN, NFC and BS fuses. 2P, 3P, 3P+N and 4P. Changeover switches Changeover switches From 40 to 3150A. 3P, 3P+N and 4P. Bypass switches From 250 to 1800A. 3P, 3P+N and 4P. Standard and customized solutions. Overlapped contacts also available. Motorised kit For switches, changeover & by-pass switches. 18

19 Notes: Telergon, S.A.U. reserves the right to modify the products herein illustrated without prior notice. Technical data and description in the catalogue are accurate at the printing date, but no liabilities for errors or omissions are accepted. No danger or hazard to health and safety will be caused when products are installed, maintained and used in applications for wich it is designed, in accordance with professional practices and manufacturer s instructions. All the products given by Telergón, are guaranteed for two years against all manufacturing defect, provided that such defect is notified within two months from the moment it is revealed. This guarantee does not include the undue or incorrect use by the user, according to the applicable regulations, nor their undue manipulation. This guarantee covers only and exclusively the replacement or repair of the faulty product. Upgrades, changes or corrections to this document at until new edition of the same. October 2011

20 Visit our web site You will find our newsletter and information about our company and range of products. A form is available to send your inquiries or to contact us. TDM-DAL-I COD Telergon, S.A.U. Ctra. Castellón (Pol. La Cartuja) Tel.: comercial@telergon.es 5020 La Cartuja Baja Fax: Zaragoza / España

Low voltage Direct Current Network. Compact NSX DC PV. Circuit breakers and switch disconnectors for solar application.

Low voltage Direct Current Network. Compact NSX DC PV. Circuit breakers and switch disconnectors for solar application. Low voltage Direct Current Network Compact NSX DC PV Circuit breakers and switch disconnectors for solar application Catalogue 2012 Compact NSX DC PV A complete DC offer for solar application from 80

More information

Emergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN 60204-1, VDE 0113 Part 1

Emergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN 60204-1, VDE 0113 Part 1 MainswitchSurfacemounting Partno. P3-63/I4/SVB Articleno. 207343 CatalogNo. SP3-063-I4CRQ IP65 Deliveryprogramme Product range Switch-disconnectors Basic function Main switches Maintenance switches Manual

More information

SIRCOVER. Manual changeover switches from 125 to 3200 A. Changeover switches. Function. Advantages. The solution for.

SIRCOVER. Manual changeover switches from 125 to 3200 A. Changeover switches. Function. Advantages. The solution for. The solution for Changeover switches svr_099_b_1_cat > Manufacturing industry. > Power distribution. 3200 Strong points svr_059_a_1_cat > complete range. > Easy connections. > Stable positions. > mproved

More information

FUSERBLOC. 20 to 1250 A Manual operation. 142 General Catalogue 2011-2012 SOCOMEC. Fuse combination switches

FUSERBLOC. 20 to 1250 A Manual operation. 142 General Catalogue 2011-2012 SOCOMEC. Fuse combination switches FUSERBLOC Fuse combination switches appli_8_a fuser_548_a cat fuser_59_a cat fuser_52_a cat 2 to 25 A Manual operation Function FUSERBLOC are manually operated multipolar fuse combination switches. They

More information

Contractors Guide Central Inverter System Installation

Contractors Guide Central Inverter System Installation Contractors Guide Central Inverter System Installation Step By Step Procedures 2,200 Watt/VA 6 Step Installation 1. Mount Bottom Cabinet 2. Mount Top Cabinet 3. Install Batteries 4. Install Conduit 5.

More information

GE Power Controls. MiniFORM Switchboards

GE Power Controls. MiniFORM Switchboards GE Power Controls MiniFORM Switchboards MiniFORM MiniFORM MiniFORM switchboards Arrangement Modules Arrangement modules 1-6 6 Arrangement modules 7-12 7 Arrangement modules 12-14 8 Arrangement modules

More information

R.C.C.B. s two-pole LEXIC

R.C.C.B. s two-pole LEXIC 87045 LIMOGES Cedex Telephone : (+33) 05 55 06 87 87 Fax : (+ 33) 05 55 06 88 88 R.C.C.B. s two-pole LEXIC 089 06/09/10/11/12/15/16/17/18/ 27/28/29/30/35, CONTENTS PAGES 1. Electrical and mechanical characteristics...

More information

RM17TE 183...528 V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

RM17TE 183...528 V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC Characteristics multifunction control relay RM17-TE - range 183..528 V AC Complementary Reset time Maximum switching voltage Minimum switching current Maximum switching current [Us] rated supply voltage

More information

NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals

NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101433D0201 28/03/11 NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals NF(Z) contactor relays are used for switching auxiliary and control circuits.

More information

LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A - 220 V AC coil

LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A - 220 V AC coil Product data sheet Characteristics LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 -

More information

Catalogue May 2015. EasyLine XLP Fuse Switch Disconnector 1-2-3-4 pole

Catalogue May 2015. EasyLine XLP Fuse Switch Disconnector 1-2-3-4 pole Catalogue May 2015 EasyLine XLP Fuse Switch Disconnector 1-2-3-4 pole Contents Introduction 1 Overview 1-pole 2 Overview 2-pole 3 Overview 3-pole 4 Overview 4-pole 5 Electronic Fuse Monitoring 6 Busbar

More information

AF09-30-22-.. / AF09Z-30-22-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals

AF09-30-22-.. / AF09Z-30-22-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101403D0201 24/03/11 AF09-30-22-.. / AF09Z-30-22-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals AF09(Z) contactors are used for controlling power circuits

More information

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2... Magnetic and Hydraulic-Magnetic Circuit Breaker 840-G2... Description Single, two and three pole magnetic circuit breakers with trip-free mechanism and push/pull on/off manual actuation. A choice of fast

More information

Photovoltaic Solar Energy Unit EESFB

Photovoltaic Solar Energy Unit EESFB Technical Teaching Equipment Photovoltaic Solar Energy Unit EESFB Products Products range Units 5.-Energy Electronic console PROCESS DIAGRAM AND UNIT ELEMENTS ALLOCATION Worlddidac Member ISO 9000: Quality

More information

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact Data sheet Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact The CT-AHD.12 is an electronic time relay with OFF-delay. It is from the CT-D range. With their MDRC profile and a width of only

More information

Manual. Solar Fountain Mobile Phone Charger

Manual. Solar Fountain Mobile Phone Charger EN Manual Solar Fountain Mobile Phone Charger Copyrights 2008 Victron Energy B.V. All Rights Reserved This publication or parts thereof may not be reproduced in any form, by any method, for any purpose.

More information

3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & 8 3. 4.0 Instructions For Installation, Operation & Maintenance

3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & 8 3. 4.0 Instructions For Installation, Operation & Maintenance SPECIFICATION FOR LOW VOLTAGE SWITCHBOARD SEN I N D E X Description 10 STANDARD TECHNICAL REQUIREMENTS 11 Standards 12 General Operating Conditions 13 General Description Of Switchboard 131 Structure 132

More information

MidNite Solar PV Combiners explained (MNPV)

MidNite Solar PV Combiners explained (MNPV) MidNite Solar PV Combiners explained (MNPV) The MNPV6 PV combiner is designed to work with 6 150V breakers or 4 touch safe 600VDC fuse holders. Busbars for both configurations are included. Based on sales,

More information

SPEEDFAX TM 2011 Disconnect Switches Contents

SPEEDFAX TM 2011 Disconnect Switches Contents SPEEDFAX TM 2011 Disconnect es Contents Compact Non-Fusible es Rotary and Toggle Selection 5-2 5-4 Dimensions and Wire Ranges 5-5 Type VBII (30-600A) Features and Ordering Information 5-6 and Handle Selection

More information

Breakers and Switches. Switches Switch-disconnectors OT, OETL, OTDC and OTM

Breakers and Switches. Switches Switch-disconnectors OT, OETL, OTDC and OTM Breakers and Switches Switches Switch-disconnectors OT, OETL, OTDC and OTM Switch-disconnectors OT 16...2500, OETL 3150, OTDC16...32 and OTM160...2500 Contents 4 Product overview, features 8 Technical

More information

Renewable energy. Inverters - Socomec G-1. Load break switches (Isolators) - Socomec G-2. Fuses - df G-3. Fuse bases.

Renewable energy. Inverters - Socomec G-1. Load break switches (Isolators) - Socomec G-2. Fuses - df G-3. Fuse bases. G Product page Inverters - Socomec G-1 Load break switches (Isolators) - Socomec G-2 Fuses - df G-3 Fuse bases Surge protection - df G-3 - Wohner G-5 - CPT G-4 - Dehn G-5 Connectors - Wieland G-6 Cable

More information

ELEKTROTEHNI KO PODJETJE Leskoπkova cesta 12, 1000 Ljubljana, SLOVENIA

ELEKTROTEHNI KO PODJETJE Leskoπkova cesta 12, 1000 Ljubljana, SLOVENIA MRO Modularne Razdelilne Omare d.o.o. ELEKTROTEHNI KO PODJETJE Leskoπkova cesta 2, 000 Ljubljana, LOVENIA MC GENERAL When to use? MC - modular switchgear cabinets are type-tested, factory built switchgears,

More information

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection) Data sheet Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection) The temperature monitoring relays CM-TCS monitor overtemperature,

More information

Digital input modules

Digital input modules 8 172 TX-I/O Digital input modules TXM1.8D TXM1.16D Two fully compatible versions: TXM1.8D: 8 inputs, each with a three-color LED (green, yellow or red) TXM1.16D: As TXM1.8X, but 16 inputs, each with a

More information

Rotary Disconnect Switch Specifications

Rotary Disconnect Switch Specifications Technical Data Rotary Disconnect Switch Specifications Bulletin Number 194R Topic Page Product Line Overview 2 General Specifications Fuse Description 12 Approximate Dimensions 14 Additional Resources

More information

Photovoltaic System Overcurrent Protection

Photovoltaic System Overcurrent Protection Photovoltaic System Overcurrent Protection Photovoltaic System Overcurrent Protection Introduction Solar Photovoltaic (PV) systems have, over the last fifty years, evolved into a mature, sustainable and

More information

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 55 Series - General purpose relays 7-10 A Features 55.12 55.13 55.14 Printed circuit mount, general purpose 2, 3 & 4 Pole relays 55.12-2 Pole 10 A 55.13-3 Pole 10 A 55.14-4 Pole 7 A AC coils & DC coils

More information

GAE953 Electrical Alarm Unit 19" with Indicator

GAE953 Electrical Alarm Unit 19 with Indicator Master Instruction 08.95 MI EIO2211 A-(en) GAE953 Electrical Alarm Unit 19" with Indicator The electrical alarm unit GAE953 gives a signal when one or two set alarm values have been exceeded. Input signals

More information

ABB Inc. April 19, 2011 Slide 1

ABB Inc. April 19, 2011 Slide 1 ABB Automation & Power World: April 18-21, 2011 Allen Austin - Solar Segment Manager North America, Low Voltage Products WLP-123-1-CEU Solar applications for low voltage products ABB Inc. April 19, 2011

More information

HM-W536 Install Guide

HM-W536 Install Guide HM-W536 Install Guide 9/13/2013 IMPORTANT SAFETY INSTRUCTIONS Warning - When using electrical devices, basic safety precautions should be followed to reduce the risk of fire, electrical shock or injury.

More information

D287/D288/D292/D293A/D293E

D287/D288/D292/D293A/D293E D87/D88/D9/D9A/D9E EN Installation Guide Smoke Detector Bases D87/D88/D9/D9A/D9E Installation Guide.0 Overview.0 Overview The D87/D88/D9/D9A/D9E Smoke Detector Bases are designed for use with the D8 Ionization

More information

RELAYS Solar Energy Systems

RELAYS Solar Energy Systems RELAYS Solar Energy Systems FUJITSU COMPONENTS CONTENTS Fujitsu relays for solar applications DC voltage versions - AC voltage versions - Latching versions RELAY PRODUCT LINE UP - SOLAR ENERGY SYSTEMS

More information

RY2 miniature industrial relays

RY2 miniature industrial relays 6 RY2 Relays of general application For plug-in sockets, 35 mm rail mount acc. to PN-EN 60715 or on panel mounting Flat insert connectors - faston x 0,5 mm Recognitions, certifications, directives: RoHS,

More information

Connecting the Power of the Sun. DC Disconnects for Solar Photovoltaic Installations. DC disconnects for. solar photovoltaic installations

Connecting the Power of the Sun. DC Disconnects for Solar Photovoltaic Installations. DC disconnects for. solar photovoltaic installations Connecting the Power of the Sun DC Disconnects for Solar Photovoltaic Installations DC disconnects for solar photovoltaic installations Solar energy is heating up Interest in renewable energy sources has

More information

8146/5 Series Breaker Panelboards

8146/5 Series Breaker Panelboards 8146/5 Series Breaker Panelboards DISTRIBUTION BREAKER PANELBOARDS FOR HAZARDOUS & CORROSIVE ENVIRONMENTS Breaker Panels Features: Wide variety of Flameproof branch circuit breakers for Zone 1 & Division

More information

SENTRON Switching and Protection Devices Air Circuit Breakers

SENTRON Switching and Protection Devices Air Circuit Breakers Siemens AG 9 SENTRON Switching and rotection Devices Air Circuit reakers 5 5/ Introduction 3WL Air Circuit reakers 3WL Air Circuit reakers/ Non-Automatic Air Circuit reakers up to 63 A (AC) 5/6 General

More information

PRODUCT GUIDE. SL Medium Voltage IEC Vacuum Contactors

PRODUCT GUIDE. SL Medium Voltage IEC Vacuum Contactors PRODUCT GUIDE SL Medium Voltage IEC Vacuum Contactors Table of Contents 1 Overview Introduction....................................................2 Features........................................................2

More information

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector Product datasheet Characteristics TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector Main Range of product Product or component type Range compatibility Enclosure material Bus

More information

400 Series Buccaneer BUCCANEER POWER. bulgin

400 Series Buccaneer BUCCANEER POWER. bulgin bulgin BUCCANEER FOR POWER Contact Retainer Sealing Gasket O Ring Contacts Locking Ring Retaining Nut Panel Body Contacts Contact Carrier O Ring Main Body Cable Gland Collet Gland Nut Sealed to IP68 when

More information

Electronic timer CT-VBS.17+18 OFF-delayed without auxiliary voltage, for DC contactors Data sheet

Electronic timer CT-VBS.17+18 OFF-delayed without auxiliary voltage, for DC contactors Data sheet Characteristics Single-function OFF-delay timer for DC contactors, without auxiliary voltage Width.5 mm CDC 5 6 F3 Approvals A culus E CCC CT-VBS a Circuit diagram b Marker label Marks a CE b C-Tick Order

More information

THE ADVANTAGES ARE YOURS

THE ADVANTAGES ARE YOURS THE ADVANTAGES ARE YOURS The new switches/discrepancy switches "R0-DR0" have special characteristics that make them very different from the normal switches on the market. Listed below are some of the many

More information

Surge Protection for Photovoltaic Systems

Surge Protection for Photovoltaic Systems Surge Protection for Photovoltaic Systems 2 photovoltaic generator disconnection boxes Index Introduction 4 Protection of PV systems 5 Surge Protection Range for PV system 6 Surge Protection Panels for

More information

PSR The compact range Description

PSR The compact range Description Description The PSR range is the most compact of all the ABB softstarter ranges, thereby making it possible to fit many devices into the same enclosure. The system concept with Manual Motor Starters provides

More information

YSmart Technology Co.,Ltd

YSmart Technology Co.,Ltd YSmart Technology Co.,Ltd GWV Series Grid Tie Microinverter User Manual The copyright of this user manual belong to YSmart TechnologyCompany Limited. Without the written permission of the copyright holder,

More information

Manual motor starter MS116

Manual motor starter MS116 Data sheet Manual motor starter MS116 Manual motor starters are electromechanical devices for motor and circuit protection. These devices offer local motor disconnect means, manual ON/ OFF control, and

More information

DRM75A 230V 20/100A DIN rail single phase two wire energy meter

DRM75A 230V 20/100A DIN rail single phase two wire energy meter DRM75A 230V 20/100A DIN rail single phase two wire energy meter 1.1 Safety instruction 1.2 Foreword 1.3 Performance criteria 1.4 Specifications 1.5 Basic errors 1.6 Description 1.7 Dimensions 1.8 Installation

More information

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages Data sheet Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages The CM-ESS.2 is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of

More information

Product and functional description

Product and functional description Product and functional description The KNX / DALI gateway N 141/02 is a 4 MU wide, DINrail mounted KNX device with one DALI interface to which up to 64 DALI actuators (e.g. DALI ballasts) can be connected

More information

Distribution Boards & Consumer Units

Distribution Boards & Consumer Units Distribution Boards & Consumer Units Enclosures for system pro M compact Distribution Boards & Consumer Units Contents General 2/ Distribution Boards Mini Center compact Mounting kits for compact accessories

More information

Safety Relays ESM/ESM-F

Safety Relays ESM/ESM-F Safety Relays ESM/ESM-F More than safety. Safety More than safety. Emil Euchner, the company s founder and inventor of the multiple limit switch, circa 1928. Around the world the Swabian specialists in

More information

UniGear ZS1. Medium voltage, arc proof, air insulated switchgear for primary distribution

UniGear ZS1. Medium voltage, arc proof, air insulated switchgear for primary distribution UniGear ZS1 Medium voltage, arc proof, air insulated switchgear for primary distribution UniGear ZS1: an innovative solution for all installation requirements ABB UniGear is medium voltage metal-clad,

More information

Thermal-Magnetic Circuit Breaker 3120-...-M1-..

Thermal-Magnetic Circuit Breaker 3120-...-M1-.. Thermal-Magnetic Circuit Breaker -...-M-.. Description Single or two pole rocker switch/thermal-magnetic circuit breaker with trip-free mechanism (S-type TM CBE to EN 34). The addition of a magnetic tripping

More information

DF-DT (G) MEDIUM VOLTAGE SWITCHGEAR THE MODULAR CONCEPT. User Manual. SGC - SwitchGear Company nv - Moorstraat 24 - B-9850 Nevele - Belgium

DF-DT (G) MEDIUM VOLTAGE SWITCHGEAR THE MODULAR CONCEPT. User Manual. SGC - SwitchGear Company nv - Moorstraat 24 - B-9850 Nevele - Belgium DF-DT (G) MEDIUM VOLTAGE SWITCHGEAR THE MODULAR CONCEPT User Manual SGC - SwitchGear Company nv - Moorstraat 24 - B-9850 Nevele - Belgium +32 (0)9/321.91.12 - Fax +32 (0)9/321.91.13 - e-mail: info@switchgearcompany.eu

More information

HS5D. Miniature Interlock Switches First in. Head Removal Detection Function for Safer Performance. First in. the Industry.

HS5D. Miniature Interlock Switches First in. Head Removal Detection Function for Safer Performance. First in. the Industry. y HS5D First in the Industry Miniature Interlock Switches First in the Industry Head Removal Detection Function for Safer Performance (*based on IDEC research, July 09) New Generation Miniature Interlock

More information

RM35UA13MW. range 15..600 V. Main. Product or component type. Relay monitored parameters

RM35UA13MW. range 15..600 V. Main. Product or component type. Relay monitored parameters Characteristics multifunction voltage control relay RM35-U - range 15..600 V Complementary Reset time Maximum switching voltage [Us] rated supply voltage Supply voltage limits Power consumption in W Main

More information

BETA Protecting SITOR Semiconductor Fuses

BETA Protecting SITOR Semiconductor Fuses BETA Protecting SITOR Semiconductor Fuses /2 Product overview /3 /17 SITOR, cylindrical fuse design /22 SILIZED, NEOZED and DIAZED design Siemens ET B1 /2008 Product overview Overview Devices Page Field

More information

SICONT Limit Switches Type 3SE3 upto 500 VAC, 600 VDC, 10A

SICONT Limit Switches Type 3SE3 upto 500 VAC, 600 VDC, 10A s SICONT Limit Switches Type 3SE3 upto 500 VAC, 600 VDC, 10A Introduction The technical and descriptive information on the function, construction and selection of the new types of 3SE3 limit switches is

More information

Control Devices Catalogue. Control Devices. Preferred and Standard Products

Control Devices Catalogue. Control Devices. Preferred and Standard Products Control Devices Catalogue Control Devices Preferred and Standard Products KOP.J Timer Electronic 22.5 mm Characteristics Mounting KOP.J 22.5 mm mono or multifunction high immunity to interference surface

More information

Three-phase monitoring relay CM-PFE

Three-phase monitoring relay CM-PFE Data sheet Three-phase monitoring relay CM-PFE The CM-PFE is a three-phase monitoring relay that monitors the phase parameter phase sequence and phase failure in three-phase mains. 2CDC 251 005 S0012 Characteristics

More information

N20xxA, N34xxA NON-SPRING RETURN DIRECT-COUPLED DAMPER ACTUATORS FOR FLOATING AND 2-POSITION CONTROL

N20xxA, N34xxA NON-SPRING RETURN DIRECT-COUPLED DAMPER ACTUATORS FOR FLOATING AND 2-POSITION CONTROL N2xxA, N34xxA NON-SPRING RETURN DIRECT-COUPLED DAMPER ACTUATORS FOR FLOATING AND 2-POSITION CONTROL SPECIFICATIONS Supply voltage N224A / N3424A N223A / N3423A PRODUCT DATA 24 Vac 15%, 5/6 Hz 23 Vac 15%,

More information

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages Data sheet Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages The CM-ESS.M is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of

More information

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application. 1SR 430 824 F9300 Features Monitoring of three-phase mains for phase sequence and failure Powered by the measuring circuit 2 c/o (SPDT) contacts 1 LED for status indication Approvals R: yellow LED - relay

More information

DC disconnects for solar photovoltaic installations. Connecting the. power of the sun

DC disconnects for solar photovoltaic installations. Connecting the. power of the sun DC disconnects for solar photovoltaic installations Connecting the power of the sun Solar energy is heating up Interest in renewable energy sources has never been greater, and the fastest growing of these

More information

PowerFlex 700S and 700H Frame 12 DC Bus Connector Kit

PowerFlex 700S and 700H Frame 12 DC Bus Connector Kit PowerFlex 700S and 700H Frame 12 DC Bus Connector Kit Installation Instructions This document provides instructions for the installation of a DC bus connector kit for PowerFlex 700S and 700H frame 12 drives

More information

How To Build A Low Voltage Capacitor Lvcp

How To Build A Low Voltage Capacitor Lvcp Low Voltage Capacitor LVCP The new choice for Power Factor Correction LVCP : the new choice for Power Factor Correction The LVCP is a compact and powerful capacitor. It offers high modularity, unmatched

More information

IEC style contactors - long electrical and mechanical life Complete range from mini-contactors to 630 Amp i n d u c t i ve AC3 ra t i n g s Wide

IEC style contactors - long electrical and mechanical life Complete range from mini-contactors to 630 Amp i n d u c t i ve AC3 ra t i n g s Wide - long al and mechanical life Complete range from mini-contactors to 630 Amp i n d u c t i ve AC3 ra t i n g s Wide range coils +0% to -30% Finger safe terminals Four-pole versions available NO + NC and

More information

HMI display Installation Guide

HMI display Installation Guide HMI display Installation Guide Product Description Specifications Important Information o Package Contents o Related Documents o Accessories Cautions and Warnings Mounting and Dimensions o BAC-DIS-ENC

More information

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous Safety relay for monitoring E-STOP pushbuttons. Approvals Unit features Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous 1 auxiliary contact (N/C), instantaneous Safe separation of

More information

TX OPEN RS232/485 module

TX OPEN RS232/485 module s 8 185 8185P01 TX-I/O ; DESIGO OPEN TX OPEN RS/485 module for integrating third-party systems and devices to DESIGO (V4 or higher) TXI1.OPEN Platform to integrate third-party systems and devices to the

More information

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS) MILLENIUM Table of contents 1. INTRODUCTION 1 2. HARDWARE DESCRIPTION 2 3. INSTALLATION 5 4. CONNECTION 6 5. USER SAFETY AND PROTECTION OF EQUIPMENT 8 1. Introduction The MILLENIUM series has been designed

More information

WE-350 Series ¼ Turn Electric Actuator

WE-350 Series ¼ Turn Electric Actuator WE-350 Series ¼ Turn Electric Actuator Operation and Installation Manual Pg 1 (Rev. 020113) Table of Contents 1.0 General 1.1 Pre-Installation Inspection 1.2 Storage 1.3 Features & General Information

More information

PLUGS & RECEPTACLES. INNOVATIVE EXPLOSION PROTECTION by R. STAHL 1-800-782-4357

PLUGS & RECEPTACLES. INNOVATIVE EXPLOSION PROTECTION by R. STAHL 1-800-782-4357 Series Features: Color coding and pin configuration makes it physically impossible to mate plugs and receptacles of different voltages and current ratings (per IEC 60 309-2). Interlocked switch mechanism

More information

MCR1900 Media Converter 19-Slot Chassis

MCR1900 Media Converter 19-Slot Chassis MCR1900 Media Converter 19-Slot Chassis Installation Guide Part #5500304-11 Copyright Statement This document must not be reproduced in any way whatsoever, either printed or electronically, without the

More information

(68.52) X. June 2000 Supercedes February 2000. xenex CONVENTIONAL FIRE DETECTION & ALARM SYSTEM. we look @ business differently

(68.52) X. June 2000 Supercedes February 2000. xenex CONVENTIONAL FIRE DETECTION & ALARM SYSTEM. we look @ business differently (68.52) X June 2000 Supercedes February 2000 xenex CONVENTIONAL FIRE DETECTION & ALARM SYSTEM.... we look @ business differently XENEX SYSTEM ARCHITECTURE Note: This schematic is for guidance only please

More information

ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories

ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories 2CDC 251 014 F0t09 Features Monitoring of three-phase mains for grid feeding Type-tested in accordance with DIN V VDE V 0126-1-1: February 2006 Neutral conductor connection configurable Can also be used

More information

Switch Actuator, 8-fold, 10 A, MDRC AT/S 8.10.1, GH Q631 0075 R0111

Switch Actuator, 8-fold, 10 A, MDRC AT/S 8.10.1, GH Q631 0075 R0111 , GH Q631 0075 R0111 The 8-fold switch actuator is a DIN rail mounted device for insertion in the distribution board. It is connected to the EIB via a bus terminal. In the event of bus voltage failure,

More information

Electronic overload relay EF19 and EF45

Electronic overload relay EF19 and EF45 Data sheet Electronic overload relay EF19 and EF45 Electronic overload relays offer reliable protection in case of overload and phase-failure. They are the alternative to thermal overload relays. Motor

More information

Solid-State Timer H3G

Solid-State Timer H3G ASH & ALAIN INDIA PVT LTD S-100, F.I.E.E., Okhla Industrial Area, Phase-ii, New Delhi-11000(India) Tel : 011-43797575 Fax : 011-43797574 E-mail : sales@ashalain.com Solid-State Timer Low-Cost, Plug-In

More information

Installation. Smart-UPS VT and MGE Galaxy 3500. Maintenance Bypass Panel with Power Distribution (wall-mount) 10-30 kva 208 V

Installation. Smart-UPS VT and MGE Galaxy 3500. Maintenance Bypass Panel with Power Distribution (wall-mount) 10-30 kva 208 V Installation Smart-UPS VT and MGE Galaxy 3500 Maintenance Bypass Panel with Power Distribution (wall-mount) 10-30 kva 208 V Contents Safety... 1 SAVE THESE INSTRUCTIONS...............................

More information

Manual Motor Starter MS 116 up to 16 A Technical Data

Manual Motor Starter MS 116 up to 16 A Technical Data Manual Motor Starter MS 116 up to 16 A Technical Data Type MS 116 Standards: Major International IEC 60 947-4-1 / IEC 60 947-2 and European Standards EN 60 947-4-1 / EN 60 947-2 Approvals, Certificates

More information

P System Cubicles. Certified for more safety

P System Cubicles. Certified for more safety P System Cubicles Prisma Plus LV Switchboards Certified for more safety Prisma Plus, an offer thought out for greater professionalism With the Prisma Plus P system, Schneider Electric proposes high-performance

More information

INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930

INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930 INSTALLATION GUIDE Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930 Card Reader and Controller Model 3.5 with KIM Swipe Reader Table of Contents 1. Features..................................

More information

NEXT SOLUTION EXPERT SOLUTION EXCELLENT SOLUTION. Super Solution

NEXT SOLUTION EXPERT SOLUTION EXCELLENT SOLUTION. Super Solution NEXT SOLUTION EXPERT SOLUTION EXCELLENT SOLUTION Super Solution Low voltage circuit breakers Susol LV circuit breakers Super Solution Contents Overview Electrical characteristics Trip units Accessories

More information

How To Mount An Ecosa Series Solar Panel

How To Mount An Ecosa Series Solar Panel (including PanelClaw ) This Guide is valid in North America only (ETL listed; conforms to UL Standard 1703) PanelClaw is a registered trademark of PanelClaw, Inc. SM-0050revA ELECTRICAL EQUIPMENT CHECK

More information

Protection and Connection. EasyLine XLP Fuse Switch Disconnector 1-2-3-4 pole

Protection and Connection. EasyLine XLP Fuse Switch Disconnector 1-2-3-4 pole Protection and Connection EasyLine XLP Fuse Switch Disconnector 1-2-3-4 pole Contents Introduction 1 Overview 1 and 2-pole 2 Overview 3-pole 3 Overview 4-pole 4 Electronic Fuse Monitoring 5 Busbar Adapters

More information

SOLAR ELECTRIC MODULE ES-124 & ES-62T Owners Manual and Installation Guide

SOLAR ELECTRIC MODULE ES-124 & ES-62T Owners Manual and Installation Guide SOLAR ELECTRIC MODULE ES-124 & ES-62T Owners Manual and Installation Guide circuit. Reverse connection will damage the module and may result in fire. CAUTIONS Solar electric modules produce DC electricity

More information

Technical catalogue. Modular DIN rail components Installation contactors

Technical catalogue. Modular DIN rail components Installation contactors Technical catalogue Modular DIN rail components Installation contactors Installation Contactors Overview... ESB Installation Contactors 0 A / AC-/AC-7a ESB0...4 4 A / AC-/AC-7a ESB4...5 40 A / AC-/AC-7a

More information

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw 4 937 DESIO Current valve for AC 24 V pulse/pause control of electrical loads up to 30 kw SEA45.1 Use The current valve is used for the control of electric heating elements in heating, ventilation and

More information

Safety Manual BT50(T) Safety relay / Expansion relay

Safety Manual BT50(T) Safety relay / Expansion relay Safety Manual BT50(T) Safety relay / Expansion relay ABB Jokab Safety Varlabergsvägen 11, SE-434 39, Sweden www.abb.com/jokabsafety Read and understand this document Please read and understand this document

More information

White Paper SolarEdge Three Phase Inverter System Design and the National Electrical Code. June 2015 Revision 1.5

White Paper SolarEdge Three Phase Inverter System Design and the National Electrical Code. June 2015 Revision 1.5 White Paper SolarEdge Three Phase Inverter System Design and the National Electrical Code June 2015 Revision 1.5 Shalhevet Bar-Asher; SolarEdge Technologies, Inc. Bill Brooks, PE; Brooks Engineering LLC

More information

Advantium 2 Plus Alarm

Advantium 2 Plus Alarm ADI 9510-B Advantium 2 Plus Alarm INSTALLATION AND OPERATING INSTRUCTIONS Carefully Read These Instructions Before Operating Carefully Read These Controls Corporation of America 1501 Harpers Road Virginia

More information

User Manual DONGGUAN SHENGYANG INDUSTRIAL CO., LTD. SY WMVC Smart Grid Tie Microinverter. Dongguan Shengyang Industrial Co., Ltd.

User Manual DONGGUAN SHENGYANG INDUSTRIAL CO., LTD. SY WMVC Smart Grid Tie Microinverter. Dongguan Shengyang Industrial Co., Ltd. DONGGUAN SHENGYANG INDUSTRIAL CO., LTD SY WMVC Smart Grid Tie Microinverter User Manual Dongguan Shengyang Industrial Co., Ltd. ADD: No. 1 Shangxin Road, New Village, Xin An Community, Chang An Town, Dongguan

More information

Square D Clipsal DIN-Rail Four-Channel Auxiliary Input Unit

Square D Clipsal DIN-Rail Four-Channel Auxiliary Input Unit Square D Clipsal DIN-Rail Four-Channel Auxiliary Input Unit SLCLE5504AUX for Use with Wired C-Bus Networks Instruction Bulletin Retain for future use. Square D Clipsal DIN-Rail Four-Channel Auxiliary Input

More information

7000 Series Buccaneer

7000 Series Buccaneer The all plastic and metal construction of the - circular that combine the ease of use of a quick coupling mechanism with proven environmental sealing for signal and mains power. Designed and independently

More information

3K Load-Break Switches The Program for Safety and Performance. sentric

3K Load-Break Switches The Program for Safety and Performance. sentric 3K Load-Break Switches The Program for Safety and Performance sentric Whether for reliable switching and isolation under load, or for protection against overload or short-circuits our 3K range of load-break

More information

40.3. Control Relays and Timers

40.3. Control Relays and Timers .3 Contents EASY500/700/800 Intelligent Relays........ EASY/MFD Expansion Modules............ MFD Intelligent Relays................... EASY/MFD Communication Modules....... EASY/MFD Power Supplies, Accessories

More information

Type: DILM9 10(24VDC) Article No.: 276705

Type: DILM9 10(24VDC) Article No.: 276705 Type: DILM9 10(24VDC) Article No.: 276705 Ordering information Rated operational current AC 3 400 V I e A 9 Max. rating for three phase motors, 50 60 Hz AC 3 230 V Max. rating for three phase motors, 50

More information

LEHI CITY POWER NET METERING STANDARDS For Customer-Owned Electric Generating Systems

LEHI CITY POWER NET METERING STANDARDS For Customer-Owned Electric Generating Systems LEHI CITY POWER NET METERING STANDARDS For Customer-Owned Electric Generating Systems A. General This Net Metering Standard for Customer-Owned Grid Connected Electric Generating Systems sets forth the

More information

Wiser Panel Meter, Model Number WISERCTPM200 Installer s Guide

Wiser Panel Meter, Model Number WISERCTPM200 Installer s Guide Instruction Bulletin EAV85226 08/2014 Wiser Panel Meter, Model Number WISERCTPM200 Installer s Guide Retain for future use. Product Description Kit Contents The Wiser Panel Meter is for use in energy management

More information

AC-115 Compact Networked Single Door Controller. Installation and User Manual

AC-115 Compact Networked Single Door Controller. Installation and User Manual AC-115 Compact Networked Single Controller Installation and User Manual December 2007 Table of Contents Table of Contents 1. Introduction...5 1.1 Key Features... 6 1.2 Technical Specifications... 7 2.

More information