CATALOG COVER FITTING PIPE CLAMP POST BASE HARDWARE A PART OF
|
|
- Leon Morgan
- 7 years ago
- Views:
Transcription
1 CATALOG COVER FITTING PIPE CLAMP POST BASE HARDWARE A PART OF
2 UNISTRUT COMMERCIAL Value-engineered fittings for commercial projects Unistrut is the standard for industrial support systems. Many commercial projects do not require the extreme strength it delivers. The marketplace is demanding products designed for sleeker installations. With that in mind, our engineers have developed Unistrut Commercial. This expanded product offering will complement our current product line by meeting the need for fittings used in lighter support applications. The line of.197 [5mm] thick fittings for use with 8 nuts and bolts is ideal to carry the equipment used in smaller commercial projects. PRODUCT FEATURES Value-engineered fittings for commercial projects Specifically designed for use with 8 nuts and bolts Hole size compatible with metric products Many selections available pre-assembled for easier installation (includes pre-installed bolt & channel nut) Lower package quantities for smaller commercial jobs Electro-galvanized coating per ASTM B66 Zinc plating All products have been fully tested and value engineered by Unistrut for optimum efficiency Products manufactured to Unistrut quality standards PRODUCT BENEFITS Can be used with any size channel, especially suited for use with 14 gauge and 16 gauge Perfect alternative to the ½ bolted system when industrial strength is not required Eliminates the need for a flat washer with 8 bolts Streamlined channel nut design offers maximum value Value engineered for competitive pricing Lighter weight, quicker installation leads to reduced labor costs Lower total installed costs Visit for comparative load ratings 2
3 PICTORIAL INDEX Hardware Hardware Hex Head Cap Screws Hex Slotted Machine Screws Hexagon Nuts Square Nuts Flat Washers Lock Washers Steel Threaded Rod Channel Nut Without Spring Channel Nut With Spring Channel Nut With Spring Pipe/Conduit Clamps Flat Fittings Pipe Clamps for Thin Wall Conduit (E.M.T.) Pipe Clamps for Rigid Steel Conduit Page 5 Square Channel Washer 2 Hole Hole Hole Elbow 4 Hole 4 Hole Elbow 4 Hole T Angle Fittings Z Shape Fittings 2 Hole 90 Fitting 2 Hole 90 Fitting 4 Hole 90 Fitting Hole Flush 90 Fitting Hole Flush 90 Fitting Hole Bench 90 Fitting 2 Hole Open 45 Fitting 1 5 8" Z 1 16" Z U Shape Fittings 1 5 8" U 1 16" U 1 5 8" Channel Splice 1 5 8" Clevis Wing, 2 Legs 1 5 8" Clevis Wing, Legs 1 5 8" 90 Wing 1 16" 2 Hole Channel Splice Post Bases Beam Clamps 1 5 8" Post Base Page 9 Brackets Page 9 C Shape Channel Beam Clamp C Shape HD Channel Beam Clamp Top Mount Beam Clamp 1 5 8" Window Beam Clamp 1 5 8" Single Channel Bracket Page " Double Channel Bracket Page 9 U-Bolt Beam Clamp Light Duty Beam Clamp Cast Beam Clamp
4 Hardware Hex Head Cap Screws Hex Slotted Machine Screws Hexagon Nuts Size Bag Quantity UCHCS025075EG 1 4" x 4" UCHCS025125EG 1 4" x 1 1 4" UCHCS07087EG* 8" x 7 8" UCHCS07125EG 8" x 1 1 4" UCHCS050125EG 1 2" x 1 1 4" UCHCS050150EG 1 2" x 1 1 2" * Assembled parts employ this bolt so the fitting will work with any channel depth. Square Nuts Size Bag Quantity UCSHS025075EG 1 4" x 4" UCSHS01100EG 5 16" x 1" UCSHS07125EG 8" x 1 1 4" Bag Size Quantity UCHXN025EG 1 4" UCHXN07EG 8" UCHXN050EG 1 2" Bag Weight Size Quantity (Ea.) UCSQN025EG 1 4" UCSQN07EG 8" Flat Washers Lock Washers Size Bag Quantity UCFLW025EG 1 4" UCFLW07EG 8" UCFLW050EG 1 2" Bag Weight Size Quantity (Ea.) UCLKW025EG 1 4" UCLKW07EG 8" UCLKW050EG 1 2" Steel Threaded Rod Channel Nut Without Spring Standard Length 10' (.0m) Size Weight (Ea.) ATHR-T-1/4-10EG 1 4" x ATHR-T-/8-10EG 8" x 16 ATHR-T-1/2-10EG 1 2" x 1 5. Low Carbon Steel Fy = 2,000 psi minimum Ft = 52,000 psi minimum Nut Size Thread UC006 1/4" EG 1 4" UC008 /8" EG 8" UC 010 1/2" EG 1 2" Use with any channel Channel Nut With Spring Nut Size Thread UC1006 1/4" EG 1 4" UC1008 /8" EG 8" UC1010 1/2" EG 1 2" Use with Any Channel except P00, P4100, P4000 Nut Size Thread UC4006 1/4" EG 1 4" UC4008 /8" EG 8" UC4010 1/2" EG 1 2" Use with P00, P4100, P4000 Channel 4
5 PIPE CLAMPS PIPE CLAMPS FOR THIN WALL CONDUIT (E.M.T.) 1 1 4" (2) Slotted hex head screw and nut included. Conduit Size In (mm) O.D. Size In (mm) Thickness Gauge (mm) Design Load UC1425 EG (/8") AS 8 (10) (14.7) 16 (1.5) UC1426 EG (1/2") AS 1 2 (1) (17.9) 16 (1.5) UC1427 EG (/4") AS 4 (19) (2.4) 16 (1.5) UC1428 EG (1") AS 1 (25) 1.16 (29.5) 16 (1.5) UC1429 EG (1 1/4") AS (2) (8.4) 16 (1.5) UC140 EG (1 1/2") AS (8) (44.2) 12 (2.7) UC141 EG (2") AS 2 (51) (55.8) 12 (2.7) UC1118 EG (2 1/2") AS (64) (7.0) 12 (2.7) UC1119 EG (") AS (76).500 (88.9) 12 (2.7) UC1120 EG ( 1/2") AS (101.6) 12 (2.7) UC1121 EG (4") AS 4 (102) (114.) 12 (2.7) PIPE CLAMPS FOR RIGID STEEL CONDUIT 1 1 4" (2) Slotted hex head screw and nut included IPS Pipe or Rigid Conduit Size In O.D. Size In (mm) Thickness Gauge (mm) Design Load UC1109 EG (/8") AS (17.1) 16 (1.5) UC1111 EG (1/2") AS (21.) 16 (1.5) UC1112 EG (/4") AS (26.7) 16 (1.5) UC111 EG (1") AS (.4) 16 (1.5) UC1114 EG (1 1/4") AS (42.2) 16 (1.5) UC1115 EG (1 1/2") AS (48.) 12 (2.7) UC1117 EG (2") AS (60.) 12 (2.7) UC1118 EG (2 1/2") AS (7.0) 12 (2.7) UC1119 EG (") AS.500 (88.9) 12 (2.7) UC1120 EG ( 1/2") AS (101.6) 12 (2.7) UC1121 EG (4") AS (114.) 12 (2.7)
6 FLAT PLATE FITTINGS SQUARE CHANNEL WASHER 2 HOLE CONNECTOR A 0.2 (5mm) Thick "A" 1 8" (80) UC1065 EG UC1065 EG AS 0.55 UC1062 EG 1 4" 0.15 UC106 EG 8" 0.1 US1064 EG 1 2" HOLE CONNECTOR HOLE ELBOW CONNECTOR 4 4" (120) 9 16" (90) UC1066 EG 0.42 UC1066 EG AS " (90) UC106 EG 0.44 UC106 EG AS HOLE CONNECTOR 4 HOLE ELBOW CONNECTOR " (160) UC1067 EG " (16) 1 2" UC180A EG 0.6 UC1067 EG AS HOLE "T" CONNECTOR " (18) 9 16" (90) UC101 EG 0.6 UC101 EG AS 1.16 "AS" parts are furnished assembled. Unless otherwise noted, fittings are.197" (5mm) thick and hole size is 7 16". Assembled components are supplied with 8" x 7 8" bolt and channel nut, for use with all channel depths. 6
7 ANGLE, Z AND U SHAPE FITTINGS 2 HOLE 90 FITTING 2 HOLE 90 FITTING " (50) 1 7 8" (47) UC1026 EG 0. UC1026 EG AS Uniform (Safety Factor 2.5) 2, " (41) 2 1 4" (57) UC1068 EG 0. UC1068 EG AS Uniform (Safety Factor 2.5) 2,000 U HOLE 90 FITTING HOLE FLUSH 90 FITTING 1 2" 1 5 8" (41) UC125 EG " (104) UC125 EG AS " (104) Uniform (Safety Factor 2.5) 4,000 U1068 UC126 EG 0.46 UC126 EG AS 0.86 Uniform (Safety Factor 2.5) 1,000 U125 U126 HOLE FLUSH 90 FITTING 1 7 8" (47) 7 8" (98) UC146 EG 0.46 UC146 EG AS 0.86 Uniform (Safety Factor 2.5) 2,000 HOLE BENCH 90 FITTING 2 16" (56) 1 2" UC1458 EG 0.46 UC1458 EG AS 0.86 Uniform (Safety Factor 2.5) 2,000 U146 U HOLE OPEN 45 FITTING "Z" CONNECTOR A 1 4" (44) " (71) UC1546 EG 0.46 UC1546 EG AS 0.7 4" (95) 1 5 8" (41) 2 1 8" (54) UC1045 EG 0.4 "AS" parts are furnished assembled. Unless otherwise noted, fittings are.197" (5mm) thick and hole size is 7 16". Assembled components are supplied with 8" x 7 8" bolt and channel nut, for use with all channel depths. 7
8 ANGLE, Z AND U SHAPE FITTINGS "U" CONNECTOR CHANNEL SPLICE " (4) 5 8" (17) 1 5 8" (41) UC1047 EG " UC176 EG CLEVIS WING, 2 LEGS CLEVIS WING, LEGS " (17) 1 7 8" (48) 2" (51) UC245 EG " (17) 1 7 8" (48) 2" (51) UC2227 EG " (42) 1 5 8" (41) WING 1 16 "Z" CONNECTOR " (49) " (49) UC222 EG 0.6 P4000 P " (88) 1 16" (21) UC4045 EG "U" CONNECTOR HOLE CHANNEL SPLICE 5 8" (17) " (4) P00 P4000 P " (21) UC4047 EG " UC476 EG 0.67 "AS" parts are furnished assembled. Unless otherwise noted, fittings are.197" (5mm) thick and hole size is 7 16". Assembled components are supplied with 8" x 7 8" bolt and channel nut, for use with all channel depths. 8
9 POST BASES & BRACKETS POST BASE SINGLE CHANNEL BRACKET 0.2" (5.0) 1 2" UC2072A EG 2.9 UC2072A SQ EG 2.9 2" (50.8) 1 4" (9.5) 9 16" (for 1 2" Bolt) (14.) 4 5 8" (117.5) P1000 A "A" UC2945 EG 12" 2.9 UC2946 EG 18" 4 UC2947 EG 24" 5 4 Holes 4" (19) Dia. 4 Holes " (150) " (150) 4" (19) Dia DOUBLE CHANNEL BRACKET 2" (50.8) " (150) UC2072A SQ " (150) UC2072A 6 1 4" (159) 9 16" (14.) A "A" UC2542 EG 12" 5 UC254 EG 18" " (6.0) P1001 UC2544 EG 24" POST BASE 0.2" (5.0) 1 2" UC2941 EG 2.82 UC2942 EG " (150) " (150) 15 16" (100) 15 16" (100) 2 Holes 2 Holes " (18) Dia " (18) Dia. UC2941 UC2942 "AS" parts are furnished assembled. Unless otherwise noted, fittings are.197" (5mm) thick and hole size is 7 16". Assembled components are supplied with 8" x 7 8" bolt and channel nut, for use with all channel depths. 9
10 BEAM CLAMPS C SHAPE CHANNEL BEAM CLAMP C SHAPE HD CHANNEL BEAM CLAMP 1 2" - 1 X 1 1 2" Set Screw Included 7 8" (22) max. 16" (5) 8" X 1 1 2" Set Screw Included UC1272S EG " (41) 7 8" (22) max UC1985S " (50) 1 16" (0) 1" (25) Total (when Used in Pairs) 750 Safety Factor 5 8" (9.5) 1 1 2" (8) Total (when Used in Pairs) 900 Safety Factor 5 TOP MOUNT BEAM CLAMP WINDOW BEAM CLAMP 1 2" (1) max " (52) 0.2" (5.0) 1 2" - 1 X 1 1 2" Hex Head Cap Screw and 1 2" Channel Nut Total (when Used in Pairs) 1,400 Safety Factor 5 UC186 EG AS " (22) max. 1 4" (45) 9 16" (90) 16" (5) 8" X 1 1 2" Set Screw Included 9 16" (90) UC1796S EG 0.69 U-BOLT BEAM CLAMP LIGHT DUTY BEAM CLAMP Mild steel "U" bolts are zinc plated. 7 8" (22) max. Hu " (75) 16" (5) H 8" U-Bolt Total (when Used in Pairs) UC ,500 UC Safety Factor 5 UC289 EG 0.14 "H" "Hu" UC2785 EG 1 5 8" 8" 0.7 UC2786 EG 1 2" 5" Safety Factor 5 CAST BEAM CLAMP Tapped for Rod Size 4" (19) Tapped Hole Size Design Load. Wt. (Ea.) UC EG 1/4" UC EG /8" UC EG 1/2" - 1 1, (safety factor 5) "AS" parts are furnished assembled. Unless otherwise noted, fittings are.197" (5mm) thick and hole size is 7 16". Assembled components are supplied with 8" x 7 8" bolt and channel nut, for use with all channel depths. 10
11 SPECIFICATIONS The technical specification for UNISTRUT COMMERCIAL products shall include all pertinent elements of the Guide Specification as provided on page 19 of the Unistrut #17 catalog including: 1 General Scope of Work Quality Assurance 01.0 Submittals Product Delivery, Storage and Handling Guarantee 2 Products 2.01 Acceptable Manufacturers 2.02 Materials 2.0 Finishes, A2 Electro-galvanized (EG) and A4 Hot-Dip Galvanized (HG) In addition to the aforementioned Product requirements the following product specifications are included for UNISTRUT COMMERCIAL metal framing fittings and components: 2.04 Design Gage: The metal framing fittings shall be light weight and high strength. The standard connection fitting gage shall be 5mm (.197 nominal) gage Standard fitting connections: Metal Framing fittings shall be provided with fastener connection holes no larger than 7/16 nominal dia. to accommodate /8 diameter fasteners Other Connections: Where ½ connections are required for trapeze drops or other similar installations, reduced gage nuts shall be employed, however nut performance in slip resistance and pull-out strength shall be equivalent to the MFMA standard requirement (latest edition) for the bolt thread size required Ergonomics: Box quantities for metal framing fittings shall weigh no more than 0 lbs maximum Products: Manufacture, Testing and Certification The metal framing system shall be constructed from press and roll-formed products produced by a single manufacturer. Products produced through other processes by third party partners (castings, fasteners, etc) shall be tested and certified by the metal framing fittings manufacturer All channel nuts shall be case hardened employing a heat treat and oil quench process to ensure consistent slip resistance All metal framing fittings shall be load rated by specific part numbers. The test set-up shall be with force applied vertical-down, beam load testing with fittings used in pairs. Test results including test set-up pictorials for fittings shall be available for submittal and review at the discretion of the owner. Allowable design loads shall be established based upon minimum safety factors applied to ultimate failure loads: Standard bolted connection fittings S.F. Pipe Clamps...5 S.F. Beam Clamps...5 S.F. Channel Nuts... S.F. Certified test results shall be available and provided if requested by the Customer Packaging All products including welded channel brackets shall be shipped to Customers in boxes, clearly labeled with part numbers, manufacturer s information, country of origin and quantity per box Box quantities shall be reduced from the standard packaging arrangements of full gage (1/4 ) standard metal framing fittings to accommodate tradesmen working at heights. Execution.01 Examination.02 Installation.0 Cleanup.04 Protection 11
12 16100 S. Lathrop Ave. Harvey, IL TOLL FREE / FAX / Atkore International, Inc. All rights reserved. USC-L-WebDocument
Sports and High Mast Lighting Poles Phone: (866) 474-7200 Fax: (817) 924-7049
Sports and High Mast Lighting Poles 4 High Mast Lighting Poles General American LitePole offers a raising and lowering system that allows for ease of maintaining the lighting system at ground level. Ideal
More information1-Way Bracket Assemblies
-Way Bracket Assemblies The Astro-Brac in its various configurations is a truly universal system for mounting signals. The Astro-Brac is designed to facilitate the mounting of any size or combination of
More informationSECTION 15140 - PIPE HANGERS AND SUPPORTS
Part I - GENERAL 1.01 SECTION INCLUDES A. The work covered under this section consists of the furnishing of all necessary labor, supervision, materials, equipment, and services to completely execute the
More informationPOWERS Controls No. 4 Pneumatic Damper Actuator
POWERS Controls No. 4 Pneumatic Damper Actuator Technical Instructions Document No. 155-032P25 AP 331-2 Actuator Assembly 331-2929 Typical Actuator Assembly 331-2904 Typical Actuator Assembly 331-3000
More informationDock Hardware & Accessory Products Catalog
Dock Hardware & Accessory Products Catalog Product Page # Product Page # Angle Brackets/Clips 8 Back Up Plate 5 Backing Plate/Hurricane Stop 10 Carriage Bolt Sets 4 Chain Retainer 10 Connector Pin Set
More informationMAST ARMS & POLES. Ornamental Pole Top & Bases
Ornamental Pole Top & Bases Pelco s decorative pole top and bases help make the traffic signal aesthetically pleasing to the eye. Available for various pole diameters and multiple finish options. Ornamental
More informationSECTION 23 05 29 - HANGERS AND SUPPORTS FOR HVAC PIPING AND EQUIPMENT
SECTION 23 05 29 - HANGERS AND SUPPORTS FOR HVAC PIPING AND EQUIPMENT PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Pipe hangers and supports. 2. Hanger rods. 3. Inserts. 4. Flashing. 5. Equipment
More informationCat. No. Finishes & Materials. Standard Finish: Electrogalvanized. Change suffix to SS6(C).
Superstrut Support Systems 1-5/8 in. x 1-5/8 in. Channel and Hardware Superstrut 1-5/8 in. x 1-5/8 in. - 12 Gauge Channel Type A Solid Base Punched Description Solid base -P Punched -HS Half slots Half
More informationConnection Solutions
Connection Solutions DESIGN BUILD SYSTEM Connection Solutions for Cold formed Steel Construction Complies with; AS/NZS 4600:2005 AISI S100:2007 AS/NZ 1397 ASTM A653 DESIGN & BUILD SYSTEM FRAMECAD Construction
More informationCable Installation Accessories. Cable Hoisting and Attachment. Snap-In Hangers. SnapStak Hangers
SnapStak Hangers New design increases stack height SnapStak hangers have become the industry standard for maximizing space utilization on crowded towers and now that utility is further expanded with the
More informationlindab duct suspension & support system Duct suspensions & Support systems
lindab duct suspension & support Duct suspensions & Support s lindab duct suspension & support Content Duct suspensions & Support s Duct suspension Duct suspension FB... DRSN... 0 DRSNR... 0 Channels and
More informationTECHNICAL SPECIFICATION FOR HIGH TENSION LINE HARDWARE AND ACCESSORIES FOR ACSR PANTHER & WOLF CONDUCTOR
TECHNICAL SPECIFICATION FOR HIGH TENSION LINE HARDWARE AND ACCESSORIES FOR ACSR PANTHER & WOLF CONDUCTOR 1.1.0 SCOPE : This specification covers design, manufacture, testing at manufacture s works before
More informationINSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks
Securitron Magnalock Corp. www.securitron.com ASSA ABLOY, the global leader Tel 800.624.5625 techsupport@securitron.com in door opening solutions INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate
More informationC O N V E Y O R C O M P O N E N T S C H A I N S B E L T S B E A R I N G S
C O N V E Y O R C O M P O N E N T S C H A I N S B E L T S B E A R I N G S January 2009 Issue 6 Valu Guide Brackets The Ultimate in Adjustability and Cost Savings Valu Guide brackets are part of a family
More informationJames M. Pleasants Company
James M. Pleasants Company SUBMITTAL DATA GAINESVILLE MECHANICAL DECEMBER 20, 2013 PROJECT: GSU: J-183 HUMANITIES LAW BLDG. QUOTE NO:12116 ENGINEER: STEVENS & WILKINSON GASKETED PLATE HEAT EXCHANGER Tag:
More informationANTENNA PARTS CATALOG
ANTENNA PARTS CATALOG Maco Antennas 302 S. East St. Mt. Carroll, IL 61053 www.macoantennas.net 815-244-3500 www.antennapartsoutlet.com SCREWS / BOLTS PART SIZE LENGTH DESCRIPTION PRICE S21 10-24 1/2" Machine
More information3M Mobile SkyWalk Series Horizontal Lifeline Product Return Form
3M Mobile SkyWalk Series Horizontal Lifeline Product Return Form THIS FULLY COMPLETED DOCUMENT MUST BE INCLUDED WITH EACH RETURN SHIPMENT IN ORDER FOR CREDIT TO BE ISSUED. ALL CREDITS WILL BE ISSUED TO
More informationATLANTA MODEL SPECIFICATIONS
ATLANTA MODEL 50 SPECIFICATIONS Dimensions: Roof Dimensions (point to point) 50-0 Column Dimensions (out to out of columns) 44-0 Eave Height 8-0 Roof Height @ Peak ±21-8⅞ Hip Roof 6:12 pitch Square Feet
More informationTARIFF CODE and updates standard
TARIFF CODE and updates standard No HS CODE AHTN CODE PRODUCT DESCRIPTION PRODUCT TYPE STANDARDS IDENTIFIED 7207 Semi finished products of iron or non alloy steel Containing by weight less than 0.25% of
More informationOVERALL CONVEYOR WIDTH STEEL ALUMINUM MODEL # PER FT. 10 FT. 5 FT. PER FT. 10 FT. 5 FT. PER FT. 10 FT. 5 FT. PER FT. 10 FT. 5 FT.
Pick Smarter. Pick Better. Pick UNEX. Skatewheel (SW) Skatewheel Gravity Conveyor is ideally suited to convey lightweight packages and where operations require portable or temporary conveyor lines such
More informationGuidelines for Earthquake Bracing of Residential Water Heaters
Guidelines for Earthquake Bracing of Residential Water Heaters Department of General Services Division of the State Architect 1102 Q Street, Suite 5100 Sacramento, CA 95814 Phone: (916) 324-7099 Fax: (916)
More informationTelescoping Post Indicator Wall Post KENNEDY VALVE ISO 9000 ISO 14001
Telescoping Post Indicator Wall Post KENNEDY VALVE ISO 9000 ISO 14001 Telescoping Post Indicator 2945 A 1" SQUARE STEM 9" MAX. = 10" MIN. = 7" FIELD ADJUSTMENT INSTRUCTIONS 1. Remove the top section from
More informationLathe Milling Attachment
Lathe Milling Attachment By L C. MASON BY CLEVERLY stacking cold-rolled flat stock together, T-slots and slide for this lathe milling attachment are made without costly machinery. In fact, only two tools,
More information60.12. Depend-O-Lok FxE Expansion Coupling. System No. Submitted By Spec Sect Para Location Date Approved Date. DEPEND-O-LOK FxE EXPANSION COUPLING
60.1 D-O-L FxE expansion couplings are a bolted, split-sleeve design that provides for expansion and contraction at the coupled joint. These couplings are furnished with restraint rings that, when affixed
More informationStructural Bolting. Notice the Grade 5 has a much smaller head configuration and a shorter shank then the A325 structural bolt. Rev.
Structural Bolting ASTM A325 and ASTM A490 are the two U.S. standard structural bolts. When looking at the mechanical requirements of bolts it appears that an ASTM A325 and SAE J429 Grade 5 are identical
More informationSECTION 26 05 49 VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS
SECTION 26 05 49 VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS PART 1 - GENERAL 1.1 SUMMARY A. This Section includes seismic restraints and other earthquake-damage-reduction measures for electrical
More informationSECTION 08332 COILING COUNTER DOORS. Display hidden notes to specifier. (Don't know how? Click Here)
SECTION 08332 COILING COUNTER DOORS Display hidden notes to specifier. (Don't know how? Click Here) PART 1 GENERAL 1.1 SECTION INCLUDES A. Coiling Metal Counter Doors. B. Coiling Counter Fire Doors. 1.2
More informationFRAME PROFILE MASONRY METAL DOOR FRAME FLUSH MASONRY KD MITER CORNER JOINT. #8 Screw (MS002485) Required on all fire rated KD frames. Bend Tabs.
FRAME PROFILE MASONRY FLUSH MASONRY KD MITER CORNER JOINT Bend Tabs Head #8 Screw (MS002485) Required on all fire rated KD frames Corner Assembly 2" (50.8) Head Jamb Head Break Away Corner Clip Spot Welds
More informationWHI 90-Minute Rated Veneered Door Frame Installation Instructions
No. 940-03-10 INSTALLATION INSTRUCTIONS 90 MINUTE RATED VENEERED DOOR FRAME DOOR REQUIREMENTS: Consult the door manufacturer to make sure that the doors are qualified for the hardware to be installed,
More informationWelcome: What is U Drain? Drain Materials. Flow
Welcome: Thank you for looking into the U Drain floor drain system. This paper will explore the functional features of the U Drain and why it is superior to other grated systems in the marketplace. We
More informationAccessories for GF and RA machines
Orbital cutting & beveling machines for high-purity process piping www.orbitalum.com Accessories for GF and RA machines A brand of ITW Orbital Cutting & Welding 23 www.orbitalum.com Orbital cutting & beveling
More informationPIPE HANGERS AND SUPPORTS PRICE LIST AND CONDENSED CATALOG
PIPE HANGERS AND SUPPORTS PRICE LIST AND CONDENSED CATALOG Price Sheet PH-11.15C Effective: November 30, 2015 Cancels Price Sheet PH-4.15C of April 5, 2015 FOR THE MOST CURRENT PRODUCT / PRICING INFORMATION
More informationManufacturing, Supply & Quality Plan for Tower Bolts. SL Tower Bolt Market Penetration
Manufacturing, Supply & Quality Plan for Tower Bolts Project: SL Tower Bolt Market Penetration Document History Version Date Original Document First Submission Feb 9, 2013 Rev1 Requested Revisions Comments
More informationCDGRD-10. Grounding. Solutions For Comm/Data Applications
CDGRD-10 Grounding Solutions For Comm/Data Applications Overview & Table of Contents Cooper B-Line s Grounding products for rack & runway provide a complete solution for grounding metal supports. The offering
More informationI BEAM TRACK INSTALLATION
PDQ 0/700 FESTOON SYSTEM INSTALLATION AND MAINTENANCE INSTRUCTIONS INTRODUCTION The PDQ Festoon System was designed to run on one of three sizes of I-beams: S x., S8 x 8. and S x.. System trolleys must
More informationHOSE, TUBE, AND PIPE CLAMPS
hose, tube & clamp B/W pages 24/6/08 9:28 AM Page 2 HOSE, TUBE, AND PIPE CLAMPS TABLE OF CONTENTS Introduction 3 Construction 3 Application 3 Mounting 3 Standard Duty Clamps (HRL) Arrangements 4 Dimensions
More informationINSTRUCTIONS THOROUGHLY BEFORE BEGINNING***************
Bill of Materials: RAC0012 Green Wing Aerodynamic Skirt Kit Item Part Number Description Quantity 1 RMC0218 Gen 2 Trailer Skirt Roadside 1 2 RMC0219 Gen 2 Trailer Skirt Curbside 1 3 RMC0041 Trailer Skirt
More informationStainless Steel Single and Dual Circulation Kits
Instruction Sheet P/N 160780 01 Stainless Steel Single and Dual Circulation Kits Introduction The single and dual high-pressure circulation kits allow you to vary and control the circulation rate of coating
More informationTwo most common lock nut groups: 1-Prevailing Torque Type Lock Nuts:
Two most common lock nut groups: 1. PREVAILING TORQUE a design feature of the lock nut produces friction between threads of mated components thereby increasing the force needed to tighten as well as loosen
More informationEMP Part # Categor Description
EMP Part # Categor y Description Qty Available as of 01/03/13 Cost/C 001014 SHC 1/4-20x1/2 J429 GR 5 Hex Hd Cap Screw Zinc Yellow 3,300 $1.41 001079 SHC 1/4-20x1 1/4 J429 GR 8 Hex Hd Cap Screw Black Oxide
More informationAUTOMATION TOOLING CATALOG ENGINEERING DATA & COMPONENT SELECTION CATALOG # 62612
AUTOMATION TOOLING CATALOG ENGINEERING DATA & COMPONENT SELECTION CATALOG # 62612 Len & Jerry's specializes in finding solutions to reduce: Weight deflection/vibration frequency cost Problems found frequently
More informationINDICATOR POST STYLE 2945 A TELESCOPING BARREL ASSEMBLY UL AND FM APPROVED
INDICATOR POST STYLE 2945 A TELESCOPING BARREL ASSEMBLY UL AND FM APPROVED Available in Sizes B C D E See Page 6 for Dimensions Kennedy Valve/Indicator Posts 17-1 INDICATOR POST STYLE 2945 A TELESCOPING
More informationHow To Launch A Rocket From A Formica
Building the Basic Bottle Rocket Launch Pad Materials: -Formica double-sink countertop cutout. This can be easily and cheaply obtained from a local company that manufactures and/or installs countertops.
More informationIt's large enough to handle most welding job shop projects, yet small enough to make it a worth while home-workshop tool
It's large enough to handle most welding job shop projects, yet small enough to make it a worth while home-workshop tool H Craft Print Project No. 272 ERE'S a metal bender that will enable you to bend
More informationINSTALLATION OF A BAY WINDOW
INSTALLATION OF A BAY WINDOW Installation of a Bay Window These instructions relate to the replacement of an existing bay window or replacement of a straight window with a new bay window, in an opening
More informationPreformed Metal Roofing and Siding
Page -1-1. GENERAL 1.1. Description This specification along with the drawings covers the furnishing of all material, products, equipment, accessories, tools, services, transportation, labor and supervision
More informationNordson Automatic Spray Gun Support Kits
Nordson Automatic Spray Gun Support Kits Customer Product Manual Issued / For parts and technical support, call the Finishing Customer Support Center at (800) -99. This document is subject to change without
More informationONTRAC WIRE MESH CABLE TRAY SYSTEM
P R O D U C T D ATA S H E E T ONTRAC WIRE MESH CABLE TRAY SYSTEM K E Y F E AT U R E S Available in two styles: Shaped and Standard Tray Easy to use pathway solution that supports large quantities of network
More informationCABLE SUPPORT SYSTEMS
CABLE SUPPORT SYSTEMS eaturing the CADDY CAT HP J-Hook System Why CADDY CAT HP? Why Choose CADDY CAT HP over tray? ast and Easy to Install Much faster installation compared to conventional cable or ladder
More informationGAS DISTRIBUTION PRODUCTS STEEL SERVICE TEES
GAS DISTRIBUTION PRODUCTS STEEL SERVICE TEES CONTINENTAL INDUSTRIES ABOUT US THE ULTIMATE CONNECTION Our Company Continental Industries, headquartered in Tulsa, Oklahoma, was formed in 1958 and is today
More informationPART 1 GENERAL 1.1 SECTION INCLUDES
J-1 Section 09110 Long Form Specification INTERIOR METAL STUD FRAMING This section includes lightweight, usually 0.036 inch (0.9 mm) thick or lighter, non-axial load bearing metal stud framing including
More informationNEW SIX-SEALS CUTTING RING. INTERNATIONAL INDUSTRIAL PATENT Nr. 864061 of the 10/03/99 FLANKS AND DOES NOT REPLACE THE STANDARD RING CURRENTLY IN USE
B4 NEW SIX-SEALS CUTTING RING. INTERNATIONAL INDUSTRIAL PATENT Nr. 864061 of the 10/03/99 FLANKS AND DOES NOT REPLACE THE STANDARD RING CURRENTLY IN USE AVAILABLE IN CARBON AND STAINLESS STEEL 23 THEORY
More informationMini USB and USB 2.0-IP67 Connector System
Mini USB and USB 2.0-IP67 Connector System Section 12 Mini USB and USB 2.0-IP67 Connector System CONEC has added the Mini-USB connector. This Mini-USB IP67 receptacle and plug family, feature a bayonet
More informationREQUEST FOR QUOTE. Material $ Labor/Installation $ tax $ Total $ Material $ Labor/Installation $ tax $ Total $
REQUEST FOR QUOTE Specifications- Knightdale Station Park Naming Rights Exterior Signage General Conditions 1. Delivery of signs to be within 6 weeks of order confirmation. 2. Shop drawings are required
More informationHose Clamps & Fittings
All Stainless Steel Marine or Underground Hose Clamps 5/16 HEX HEAD SCREW 60000 SERIES Highly corrosion resistant Use for marine or underground applications Stainless Steel Band, Housing Plated Steel Screw
More informationMueller B-101 and A-3 Drilling and Tapping Machines
TM TM Mueller and Drilling and Tapping Machines A guide to selecting Mueller Equipment Mueller TM TM and Drilling and Tapping Machines When it comes to line stopping and drilling and tapping technology
More informationCP2 Buried Cable Pedestal Initial & Rehab Installation Instructions
Printing 3 March 2008 CP2 Buried Cable Pedestal Initial & Rehab Installation Instructions This instruction is intended for CP2 cable pedestal installations and replacements. The following tools will be
More informationGuidelines for Earthquake Bracing Residential Water Heaters
Guidelines for Earthquake Bracing Residential Water Heaters Department of General Services Division of the State Architect In accordance with the Health and Safety Code Section 19215, the Division of the
More informationPower Cube Open Source Ecology Page 1. Power Cube. Version 4
Power Cube Open Source Ecology Page 1 Power Cube Version 4 Power Cube Open Source Ecology Page 2 Contents Table of Contents Power Cube... 1 Contents...2 Introduction... 3 Bill Of Materials...4 Discrete
More informationCLEAR-DIVISIONS APERTO
CLEAR-DIVISIONS Introduction: The following three (3) part specification offers the Standard and Optional features for the CLEAR-DIVISIONS moveable glass wall system. The yellow highlighted areas in the
More informationRollers. from the UK s largest roller manufacturer. Quality Performance Reliability
Rollers from the UK s largest roller manufacturer Quality Performance Reliability 42 Index Gravity Rollers Light to Medium Duty 4 Heavy Duty 5 Plastic Rollers 6 Stainless Steel Rollers 7 Grooved Rollers
More informationBIS Metal Pipe Clamps with Lining
A BIS Metal Pipe Clamps with Lining BIS Clamps BISMAT Flash BISMAT 2000 Ø ¼ - 2" BISMAT 2000 Ø 2½ - 4" 2 3 4 BIS Industrial Clamps BIS Heavy Duty Clamps HD1501 (1/2") (BUP1000) 5 BIS Clamps for Plastic
More informationCALCULATION & DRAFTING STANDARDS MANUAL PROCEDURE: C&D 515 Bill of Materials Standard REV 0.0 5/6/04
BROWN MINNEAPOLIS TANK PAGE 1 OF 7 PURPOSE: Create and Drawing Uniformity Create, explain, and establish a standard bill of materials to be placed on every drawing (except the overall tank elevation and
More informationPARTS & SERVICE MANUAL for CONTEMPO SERIES WARMER LAMPS
PARTS & SERVICE MANUAL for CONTEMPO SERIES WARMER LAMPS Merco Contempo Warmer Lamps offer graceful, dramatic styling to match any décor. They are made of exacting tolerance from heavy duty, solid, mandrelspun
More informationHOUSTON COMMUNITY COLLEGE HCC ALIEF CAMPUS MAIN BUILDING, FIRST, SECOND & FOURTH FLOORS RENOVATION ISSUE DATE: 10.17.12
SECTION 27 05 26 - GROUNDING AND BONDING FOR COMMUNICATIONS SYSTEMS PART 1 - GENERAL 1.1 SUMMARY A. This Section includes grounding and bonding products, design requirements and installation for communications
More informationSection M POWER LIFTS
Section M POWER LIFTS December 2009 1M Index 1. 53-520244-000 Poly V Idler Assembly 2. 53-520205-000 N.A. Mounting Bracket 3. 53-520212-000 Cable Assembly 4. 53-600149-000 Wire Harness Assembly 5. 53-860322-010
More informationElo Touch Solutions Wall-mounting Kit for the 5501L IDS Touchmonitors
Installation Manual Elo Touch Solutions Wall-mounting Kit for the 5501L IDS Touchmonitors SW602206 Rev B Table of Contents Chapter 1: Safety Warning... 3 Chapter 2: Kit Contents... 4 Included in Kit...
More informationTS 813 GROUNDING AND BONDING TTD 813.001 TRAFFIC SIGNAL INSTALLATION AND CONTROLLER CABINET GROUNDING SYSTEM TTD 813.005 CONTROLLER CABINET GROUNDING
TORONTO TRANSPORTATION January 2012 TS 813 GROUNDING AND BONDING TABLE OF CONTENTS 1. DRAWINGS TTD 813.001 TRAFFIC SIGNAL INSTALLATION AND CONTROLLER CABINET GROUNDING SYSTEM TTD 813.005 CONTROLLER CABINET
More informationGEET Fuel Processor Plans
GEET Fuel Processor Plans This is a greatly simplified Proof of Concept version of the GEET Fuel Processor that just about anyone can build from parts from a local Hardware store in a weekend for very
More informationCT-02 CABLE TRAY SYSTEMS
CT-02 CABLE TRAY SYSTEMS SYSTEMS THAT MAKE SENSE Introduction B-Line Systems was formed in 96 and has over 30 years experience manufacturing cable tray systems in which it has grown to become the industry
More informationCable Support Solutions
Cable Support Solutions B-Line by Eaton Technology Day Japan 2013 2012 Eaton Corporation. All rights reserved. 2012 Eaton Corporation. All rights reserved. 2012 Eaton Corporation. All rights reserved.
More informationResidential Deck Safety, Construction, and Repair
Juneau Permit Center, 4 th Floor Marine View Center, (907)586-0770 This handout is designed to help you build your deck to comply with the 2006 International Residential Building code as modified by the
More informationPRESENTATION ON REPAIR AND REHABILITATION OF BUILDINGS DAMAGED IN EARTHQUAKE. By H P Gupta & D K Gupta
PRESENTATION ON REPAIR AND REHABILITATION OF BUILDINGS DAMAGED IN EARTHQUAKE By H P Gupta & D K Gupta DIFFERENT TYPES OF DAMAGES 1.Minor cracks 0.5 to 5 mm wide in load or non-load bearing walls 2.Major
More informationCLEAR-DIVISIONS CENTERFOLD
CLEAR-DIVISIONS CENTERFOLD Introduction: The following three (3) part specification offers the Standard and Optional features for the CLEAR-DIVISIONS CENTERFOLD moveable The yellow highlighted areas in
More informationThis mount uses concrete parking bumpers and a Davis tripod to create a mounting solution for nonpenetrable
NON-PENETRATING FLAT ROOF MOUNT Application Note 18 For Any Davis Weather Station Installed on a Mounting Tripod Introduction This application note describes various mounting solutions for non-penetrable
More informationSECTION 02720 SANITARY SEWER AND STORM DRAIN SYSTEMS
SECTION 02720 SANITARY SEWER AND STORM DRAIN SYSTEMS PART 1 GENERAL 1.01 SECTION INCLUDES A. The requirements for pipe material and installation in sewer and drainage collection systems. All materials
More informationFixturing systems Fixturing systems for measurement technology
Fixturing systems Fixturing systems for measurement technology Innovations and new additions to range Sets Spannfix Eco complete set The set contains different supports, extension elements and stop units.
More informationCable Runways & Accessories
SB17U SB13AL SB17 SB17T SB117 SB17HRB SB2107 SB2101A SB17VRB SB2110A SB2129 SB2129SD SB130 SB2221 SB126 SB2118 SB119 SB2105 113 Cooper B-Line manufactures a wide variety of high quality cable pathway products
More informationLiftAlloy Chain Slings
CHAIN SLING BASICS Slings Lift-All chain slings meet or exceed all OSHA, ASME B30.9 and NACM standards and regulations. chain slings, available in 80 for 7/32" and 7/8"- /4" and 00 for 9/32"-3/4", are
More informationROOF DRAINS TABLE OF CONTENTS
Pictorial Index Product Recommendations Roof Drain Selection Factors Sizing Placement Material & Characteristics Pipe Connection Commonly Specified Options Typical Installations TABLE OF CONTENTS ROOF
More informationAccessories. KwikWire Clamps. KwikWire Clamp Working Loads* 78205140719 BKC100 1 /16" & 3 /32" 100 78205140723 BKC200 1 /8" & 3 /16" 50
KwikWire Clamps KwikWire system replaces jack chain or ATR to support lighting, ductwork, cable tray, etc. Can be quickly installed around beams - No drilling required. Ideal for sloped ceilings - can
More informationType 1, 3, & 3R Enclosures
Junction oxes Type 1 Screw over....................................................................... 50-53 Junction oxes Type 1 Hinge over........................................................................
More informationLEGACY REPORT ER-5110. www.icc-es.org. ICC Evaluation Service, Inc. Reissued November 1, 2003. Legacy report on the 1997 Uniform Building Code
LEGACY REPORT Reissued November 1, 2003 ICC Evaluation Service, Inc. www.icc-es.org Business/Regional Office # 5360 Workman Mill Road, Whittier, California 90601 # (562) 699-0543 Regional Office # 900
More informationFRONT BUMPER INSTALLATION INSTRUCTIONS 2007-2011 DODGE / MERCEDES SPRINTER
Aluminess Products Inc 9402 Wheatlands Ct. #A Santee, CA 92071 619-449-9930 FRONT BUMPER INSTALLATION INSTRUCTIONS 2007-2011 DODGE / MERCEDES SPRINTER Please read before beginning Stainless steel hardware
More informationIncludes specifications for: Surface Cleaning & Mounting Hardware.
Three-Part Specifications - Copyright 2014 - Nixalite of America Inc Bird Screen Welded Wire Mesh Barriers Includes specifications for: Surface Cleaning & Mounting Hardware. Nixalite offers full rolls
More informationSolar Mounting System
Xiamen Antai New Energy Tech.Co., Ltd Installation Manual Antai Rail Solar Mounting System (Flat Roof Solution) Version 1.1 Office Add: 508#, North Tower, Guangxia Building Huli Torch Hi-tech Zone, Xiamen,
More informationGUIDELINES FOR INSTALLATION OF AIR CONDITIONING UNITS 174-180 PHILLIP STREET, SYDNEY
GUIDELINES FOR INSTALLATION OF AIR CONDITIONING UNITS 174-180 PHILLIP STREET, SYDNEY July 2008 1.0 SCOPE These guidelines describe the way in which air conditioning units shall be installed or replaced
More informationEHV CONNECTORS EHV TERMINALS ACFS (EHV)... ALUMINUM BOLTED TUBE TO FLAT PAD, SHORT...EHV-7
CONNECTORS TERMINALS ACF ()... BOLTED TUBE TO FLAT PAD...- ACFS ()... BOLTED TUBE TO FLAT PAD, SHORT...-7 CCL-... COMPRESSION TUBE TO FLAT PAD...- CCLS-... COMPRESSION TUBE TO FLAT PAD, SHORT... - EVKET...
More informationAssembly Instructions Model 1544 Heart-Of-The-Kitchen Island
Assembly Instructions Model 1544 Heart-Of-The-Kitchen Island A. These units are Ready-to-Assemble. Catskill uses positive fastening methods such as wood screws and in some places hidden Bastion fasteners.
More informationThere is no upside to. down time
EXPANDED and PERFORATED Data and Specifications 30 Similar to Type 302 with excellent mechanical properties, resistance to many corrosive agents. Useful where sanitation and cleanliness are important.
More informationKNIFE GRINDER MATERIALS LIST & CONSTRUCTION TIPS by Michael Clerc mike.clerc@cox.net
KNIFE GRINDER MATERIALS LIST & CONSTRUCTION TIPS by Michael Clerc mike.clerc@cox.net Materials List Minimum tools required: Drill press & Drill bits ("#7", "F", 5 / 16 ", ¼", 17/64", ½", "O", 1") Tap Handle
More informationI-Line. Accessories. Essential cable installation products for corrugated, smooth wall, and braided cables
I-Line TM Essential cable installation products for corrugated, smooth wall, and braided cables Installation Coaxial cable installation components for corrugated, smooth wall and braided cables Proven
More information123 Industrial Loop Road Paynesville, MN 56362 Phone: 1-800-864-1649 www.master-mfg.com
123 Industrial Loop Road Paynesville, MN 56362 Phone: 1-800-864-1649 www.master-mfg.com INTRODUCTION The purpose of this manual is to assist you in the assembly, operation and maintenance of your sprayer
More informationSPECIFICATIONS FOR BOON EDAM TOMSED MODEL TUT-65TMB
SPECIFICATIONS FOR BOON EDAM TOMSED MODEL TUT-65TMB PRODUCT DESCRIPTION: BOON EDAM TOMSED MODEL TUT-65TMB STAINLESS STEEL BARCODE SCANNING ELECTRONIC REGISTERING TURNSTILE SCOPE OF OPERATION: A. The TUT-65TMB
More informationThe Keep It Simple, Steel (KISS) Standard
The Keep It Simple, Steel (KISS) Standard A standard Electronic Data Interchange (EDI) format for the exchange of Bill of Material (BOM) information within the steel fabrication industry Updated in March
More informationIntroduction to JIGS AND FIXTURES
Introduction to JIGS AND FIXTURES Introduction The successful running of any mass production depends upon the interchangeability to facilitate easy assembly and reduction of unit cost. Mass production
More informationFasteners and screw threads
ISO Standards Handbook: Fasteners and screw threads Volume 2: Product standards Contents Part 3 : Product standards 2001, Ed. 5, 1094 p., ISBN 92-67-10345-8 3.1 External drive hexagon head bolts and screws
More informationRING JOINT SYSTEMS 207
RING JOINT SYSTEMS 07 08 Table of Contents Model R-88 Pages 10-11 Model R-88 Large Diameter Page 1 Model RH-1000 1000 PSI Coupling Page 13 Model RX-3000 3000 PSI Coupling Page 1 Model RX-3770 3770 PSI
More informationDESCRIPTION. Stud Bolts for Pressure-Temperature Piping 2-1. General Purpose End-to-End Studs 2-2. Tap End Stud Bolts 2-3. Double End Stud Bolts 2-4
DESCRIPTION PAGE B7 Studs and Nuts Stud Bolts for Pressure-Temperature Piping 2-1 General Purpose End-to-End Studs 2-2 Tap End Stud Bolts 2-3 Double End Stud Bolts 2-4 Sigma Fasteners, Inc. Section 2 STUD
More information