Type 1, 3, & 3R Enclosures

Size: px
Start display at page:

Download "Type 1, 3, & 3R Enclosures"

Transcription

1 Junction oxes Type 1 Screw over Junction oxes Type 1 Hinge over Junction oxes Type 3R Screw over Junction oxes Type 3R Hinge over Junction oxes Type 3 Screw over Gasketed Junction oxes Type 3 Weatherproof Screw over Panel Enclosures Type 1 Small Panel Enclosures Type 1 Medium Panel Enclosures Type 1 Large Panel Enclosures Type 1 Locking Hinge over w/perforated Panel Panel Enclosures Type 3R Small ontinuous Hinge over Panel Enclosures Type 3R Large ontinuous Hinge over Panel Enclosures Type 3R Double-Door Utility abinets Type 1 Telephone abinets Utility abinets Type 3R Telephone abinets Utility abinets Type 3R Screw over urrent Transformer abinets Utility abinets Type 3R Hinge over urrent Transformer abinets

2 Junction oxes Type 1 Screw over - Painted & Galvanized Data and Illustration Sheet Finish Wash and phosphate undercoat or galvanized steel NSI 61 gray acrylic electrocoat finish pplication Used as wiring boxes, junction and pull boxes Protects against contact with enclosed equipment Standards UL 50 listed, Type 1 S 22.2 No. 40 certified, Type 1 onforms to NEM standard for Type 1 ccessories Ground lug kit Touch-up paint See ccessories section onstruction Enclosure and cover are fabricated from code gauge steel or galvanized steel, (see table) Enclosure body has mounting holes on the back Enclosures are available with or without knockouts on the sides, top and bottom ends over is secured to the body with plated hex head combo screws Keyhole slots provided in the cover allow easy access to the inside without removing the screws #10-32 tapped hole provision for optional ground lug kit Discount Schedule: 2 Subclass: N0 & X1 (**) (25) (25) (**).25 (6) mounting hole (4PL) knockout area (see table for pattern, see detail for size) Front View Side View knockout area (see table for pattern, see detail for size) Dimensions: ** = (-1.90) if 16 or 14 gauge (-3.90) if 12 gauge ** = (-2.00) if 16 or 14 gauge (-4.00) if 12 gauge ottom View Notes: ooper -Line can provide special sizes, finishes and other modifications. onsult the factory for your special requirements. Dimensions are in inches. Millimeters shown are for reference only. Data subject to change without notice. 50

3 Junction oxes Type 1 Screw over - Painted & Galvanized atalog Number Enclosure atalog Number Enclosure Size Knockout Knockout Pattern Pattern Painted Galvanized Height x Width x Depth x x KO No KO KO No KO in. mm Gauge Each Side Top & ottom 443 S 443 S NK 443 SGV 443 SGV NK 4.00 x 4.00 x x 102 x D D 444 S 444 S NK 444 SGV 444 SGV NK 4.00 x 4.00 x x 102 x D D 644 S 644 S NK 644 SGV 644 SGV NK 6.00 x 4.00 x x 102 x D E D 663 S 663 S NK 663 SGV 663 SGV NK 6.00 x 6.00 x x 152 x D E D E 664 S 664 S NK 664 SGV 664 SGV NK 6.00 x 6.00 x x 152 x D E D E 863 S 863 S NK 863 SGV 863 SGV NK 8.00 x 6.00 x x 152 x D E 864 S 864 S NK 864 SGV 864 SGV NK 8.00 x 6.00 x x 152 x D E 884 S 884 S NK 884 SGV 884 SGV NK 8.00 x 8.00 x x 203 x S NK SGV NK x 6.00 x x 152 x S 1084 S NK 1084 SGV 1084 SGV NK x 8.00 x x 203 x S S NK SGV SGV NK x x x 254 x S 1264 S NK SGV NK x 6.00 x x 152 x D E 1284 S 1284 S NK 1284 SGV 1284 SGV NK x 8.00 x x 203 x S S NK SGV SGV NK x x x 254 x S S NK SGV SGV NK x x x 305 x S NK SGV x x x 381 x I I S S NK SGV SGV NK x x x 305 x I S S NK SGV x x x 406 x I I S S NK SGV SGV NK x x x 305 x I J S NK SGV x x x 381 x I J I S S NK SGV SGV NK x x x 457 x I J I J S S NK SGV x x x 305 x I J S NK SGV x x x 457 x I J I J S S NK SGV SGV NK x x x 610 x I J I J S NK SGV SGV NK x x x 457 x I J I J S S NK SGV SGV NK x x x 610 x I J I J S NK SGV NK x x x 762 x (47) 1.87 (47) 3 /4-1 D 3 /4-1 E F /4 G H 3 /4-1 I J 3 /4-1 K onduit Sizes Knockout Detail Note: See table for applicable knockout pattern. 51

4 Junction oxes Type 1 Screw over - Painted & Galvanized atalog Number Enclosure atalog Number Enclosure Size Knockout Knockout Painted Galvanized Height x Width x Depth Pattern Pattern x x KO No KO KO No KO in. mm Gauge Each Side Top & ottom 666 S 666 S NK 666 SGV 666 SGV NK 6.00 x 6.00 x x 152 x D E D E 866 S 866 S NK 866 SGV 866 SGV NK 8.00x 6.00 x x 152 x D E 886 S 886 S NK 886 SGV 886 SGV NK 8.00 x 8.00 x x 203 x S 1086 S NK 1086 SGV 1086 SGV NK x 8.00 x x 203 x S S NK SGV SGV NK x x x 254 x S NK x 6.00 x x 152 x S NK SGV NK x 8.00 x x 203 x S S NK SGV SGV NK x x x 254 x S S NK SGV SGV NK x x x 305 x S NK SGV NK x x x 381 x S S NK SGV SGV NK x x x 305 x I S S NK SGV SGV NK x x x 406x I I J S S NK SGV SGV NK x x x 305x I J S NK SGV NK x x x 381x S S NK SGV SGV NK x x x 457x I J I J S NK SGV NK x x x 305x S S NK SGV SGV NK x x x 457x I J I J S NK SGV NK x x x 508x S S NK SGV SGV NK x x x 610x I J I J S NK SGV NK x x x 457 x S S NK SGV SGV NK x x x 610 x I J I J S NK SGV NK x x x 762 x S S NK SGV NK x x x 310 x I J I J S NK SGV NK x x x 762 x S NK SGV NK x x x 914 x S NK SGV NK x x x 914 x S NK SGV NK x x x 1219 x S 888 S NK 888 SGV 888 SGV NK 8.00 x 8.00 x x 203 x S NK SGV NK x x x 254 x S S NK SGV NK x x x 305 x S S NK SGV NK x x x 305 x I S S NK SGV NK x x x 305 x I J S S NK SGV NK x x x 457 x I J I J S S NK SGV NK x x x 305 x I J S S NK SGV NK x x x 457 x I J I J S NK SGV NK x x x 508 x S S NK SGV NK x x x 610 x I J I J S S NK SGV SGV NK x x x 610 x I J I J S NK SGV NK x x x 762 x S S NK SGV NK x x x 610 x I J I J S NK SGV NK x x x 762 x (47) 1.87 (47) 1 /2-3 /4 3 /4-1 1 /2-3 /4 D 3 /4-1 E 1 /2-3 /4 F /4 G 1 /2-3 /4 onduit Sizes Knockout Detail - Note: See table for applicable knockout pattern. 52 H 3 /4-1 I 1 /2-3 /4 J 3 /4-1 K 1 /2-3 /4

5 Junction oxes Type 1 Screw over - Painted & Galvanized atalog Number Enclosure atalog Number Enclosure Size Knockout Knockout Painted Galvanized Height x Width x Depth x x Pattern Pattern KO No KO KO No KO in. mm Gauge Each Side Top & ottom S NK SGV NK x x x 305 x S S NK SGV NK x x x 305 x I J S S NK SGV NK x x x 457 x I J I J S NK SGV NK x x x 305 x S S NK SGV NK x x x 457 x I J I J S S NK SGV NK x x x 610 x I J I J S NK SGV NK x x x 610 x S NK SGV NK x x x 762 x S NK SGV NK x x x 610x x S NK SGV NK x x x 914 x S NK SGV NK x x x 305 x S S NK SGV NK x x x 457 x I J I J S S NK SGV NK x x x 305 x I J S S NK SGV NK x x x 457 x I J I J S S NK SGV NK x x x 610 x I J I J S S NK SGV NK x x x 610 x I J I J S NK SGV NK x x x 762 x S S NK SGV NK x x `14 x 610 x I J I J S NK SGV NK x x x 1219 x S NK SGV NK x x x 1219 x S NK x x x 762 x S NK SGV NK x x x 1219 x S NK SGV NK x x x 1219 x Type 1 Flush & Surface overs - Painted & Galvanized atalog Number Discount Schedule: 2 Subclass: N0 Optional Flush over Fits Replacement Surface over Fits Flush overs Size Enclosure Surface overs Size Enclosure atalog Number x atalog Number x Painted Galvanized in. mm in. mm Gauge Painted Galvanized in. mm in. mm Gauge 44 SF x x x x SF x x x x SS x x x x SF x x x x SF x x x x SS x x x x SF x x x x SF x x x x SS x x x x SF x x x x SF x x x x SS x x x x SF x x x x SF x x x x SF x x x x SS x x x x SF x x x x SF x x x x SS x x x x

6 Junction oxes Type 1 Hinge over Data Sheet and atalog Number Finish Wash and phosphate undercoat NSI 61 gray acrylic electrocoat finish pplication Used as wiring boxes, junction and pull boxes Protects against contact with enclosed equipment Standards UL 50 listed, Type 1 S 22.2 No. 40 certified, Type 1 onforms to NEM standard for Type 1 ccessories Ground lug kit Touch-up paint See ccessories section onstruction Enclosure and cover are fabricated from (16) gauge steel Enclosure body has mounting holes on the back Enclosures are available with or without knockouts on the sides, top and bottom ends Removable cover is secured to the body with T-Slot hinges on one side and a friction dimple catch on the opposite side over is furnished with a recessed pull ring for opening convenience #10-32 tapped hole provision for optional ground lug kit Discount Schedule: 2 Subclass: O0 Enclosure Enclosure Size Knockout Knockout atalog Number Height x Width x Depth Pattern Pattern x x KO No KO in. mm Each Side Top & ottom 664 H 664 H NK 6.00 x 6.00 x x 152 x H 864 H NK 8.00 x 6.00 x x 152 x H 884 H NK 8.00 x 8.00 x x x 203 x H 1084 H NK x 8.00 x x 203 x H H NK x x x 254 x H 1284 H NK x 8.00 x x 203 x H H NK x x x 254 x H H NK x x x 305 x H H NK x x x 305 x H 666 H NK 6.00 x 6.00 x x 152 x H 886 H NK 8.00 x 8.00 x x 203 x H 1086 H NK x 8.00 x x 203 x H H NK x x x 254 x H H NK x x x 254 x H H NK x x x 305 x H H NK x x x 305 x H H NK x x x 406 x H H NK x x x 305 x H H NK x x x 457 x H H NK x x x 457 x H H NK x x x 610 x H H NK x x x 610 x H H NK x x x 610 x H H NK x x x 610 x 203 D E D E D E I J D E D E I I I I J I J I J I J I J I J I J I J I J I J I J I J I J Notes: ooper -Line can provide special sizes, finishes and other modifications. onsult the factory for your special requirements. Dimensions are in inches. Millimeters shown are for reference only. Data subject to change without notice. 54

7 Junction oxes Type 1 Hinge over Illustration Sheet (51) pull ring friction dimple knockout area (see table for pattern, see detail for size) (51) Front View.25 (6) mounting hole (4PL) Side View T-Slot hinge knockout area (see table for pattern, see detail for size) ottom View 1.87 (47) 1.87 (47) 3 /4-1 D 3 /4-1 E F /4 G H 3 /4-1 I J 3 /4-1 K onduit Sizes Knockout Detail Note: See table for applicable knockout pattern. 55

8 Junction oxes Type 3R Screw over - Painted & Galvanized Data and Illustration Sheet pplication Used as wiring boxes, junction and pull boxes Protects against falling rain, sleet and external ice formation ccessories Touch-up paint See ccessories section onstruction Enclosure and cover are fabricated from code gauge galvaneal steel for painted or galvanized steel, (see table, page 57) Enclosure body has embossed mounting holes on the back vailable with or without knockouts on the bottom end of enclosures less than 30 inches wide over is held secure by sliding it under the top end flange and fastening it with plated screws on the bottom end flange, (larger sizes use two studs and wing nuts) Discount Schedule: 2 Subclass: S0 & Z60 Standards UL 50 listed, Type 3R S 22.2 No. 40 certified, Type 3R onforms to NEM standard for Type 3R E Finish Wash and phosphate undercoat NSI 61 gray acrylic electrocoat finish D knockout area (see table for pattern, see detail for size) ottom View 1.87 (47) 1.87 (47) Front View.25 (6) mounting hole (4PL) 3 /4-1 D 3 /4-1 E F /4 G H 3 /4-1 I J 3 /4-1 K onduit Sizes Knockout Detail Note: See table for applicable knockout pattern. Notes: ooper -Line can provide special sizes, finishes and other modifications. onsult the factory for your special requirements. Dimensions are in inches. Millimeters shown are for reference only. Data subject to change without notice. 56

9 Junction oxes - Type 3R Screw over - Painted & Galvanized atalog Number Enclosure atalog Number Enclosure Size Knockout Height x Width x Dept Pattern Painted Galvanized x x D E KO No KO KO No KO in. mm in. mm in. mm Gauge ottom 444 RTS 444 RTS NK 444 RTSGV x 4.00 x x 102 x RTS 644 RTS NK x 4.00 x x 102 x RTS 664 RTS NK 664 RTSGV 664 RTSGV NK 6.00 x 6.00 x x 152 x RTS 864 RTS NK x 6.00 x x 152 x RTS 884 RTS NK 884 RTSGV 884 RTSGV NK 8.00 x 8.00 x x 203 x RTS 1084 RTS NK x 8.00 x x 203 x RTS RTS NK RTSGV RTSGV NK x x x 254 x RTS 1284 RTS NK x 8.00 x x 203 x RTS RTS NK x x x 254 x RTS RTS NK RTSGV RTSGV NK x x x 305 x RTS x x x 305 x RTS RTS NK x x x 305 x RTS RTS NK x x x 406 x RTS x x x 305 x RTS RTS NK x x x 457 x RTS RTS NK x x x 610 x RTS 666 RTS NK 666 RTSGV 666 RTSGV NK 6.00 x 6.00 x x 152 x RTS 866 RTS NK x 6.00 x x 152 x RTS 886 RTS NK 886 RTSGV 886 RTSGV NK 8.00 x 8.00 x x 203 x RTS 1086 RTS NK x 8.00 x x 203 x RTS RTS NK RTSGV RTSGV NK x x x 254 x RTS x 8.00 x x 203 x RTS RTS NK x x x 254 x RTS RTS NK RTSGV RTSGV NK x x x 305 x RTS RTS NK x x x 305 x RTS RTS NK x x x 406 x RTS RTS NK RTSGV NK x x x 305 x RTS RTS NK RTSGV RTSGV NK x x x 457 x RTS RTS NK x x x 305 x RTS RTS NK x x x 457 x RTS RTS NK RTSGV NK x x x 610 x RTS NK x x x 914 x RTS RTS NK RTSGV NK x x x 254 x RTS RTS NK RTSGV NK x x x 305 x RTS RTS NK x x x 305 x RTS RTS NK RTSGV NK x x x 457 x I J RTS RTS NK x x x 406 x I RTS RTS NK x x x 457 x I J RTS RTS NK RTSGV NK x x x 610 x I J RTS NK x x x 914 x RTS RTS NK x x x 305 x RTS x x x 305 x RTS RTS NK x x x 457 x RTS RTS NK x x x 457 x RTS RTS NK RTSGV NK x x x 610 x RTS RTS NK x x x 610 x RTS NK x x x 762 x RTS RTS NK RTSGV NK x x x 610 x RTS RTS NK x x x 610 x I I J I J I I J I J I J RTS NK x x x x 762 x RTS RTS NK x x x 610 x I J RTS NK x x x 762 x RTS NK RTSGV NK x x x 914 x D E D E D E D E D E D E D E D E D E D E D E D E D E D D D E D E F G H F G H F G H F G H F G H F G H D E D E F G H F G H F G H F G H F G H F G H F G H I J I J I J I J I J I J

10 Junction oxes Type 3R Hinge over Data Sheet and atalog Number Finish Wash and phosphate undercoat NSI 61 gray acrylic electrocoat finish pplication Used as wiring boxes, junction and pull boxes Protects against falling rain, sleet and external ice formation Standards UL 50 listed, Type 3R S 22.2 No. 40 certified, Type 3R onforms to NEM standard for Type 3R ccessories Touch-up paint See ccessories section onstruction Enclosure and door are fabricated from code gauge galvaneal steel, (see table) Enclosure body has embossed mounting holes on the back vailable with or without knockouts on the bottom end of enclosures less than 30 inches wide over is secured to the top end with galvanized, detachable formed hinges on sizes up to and including over can be held in the open position by sliding it into notches on body over has padlock hasp and sealing hole provisions at the bottom Discount Schedule: 2 Subclass: T0 Enclosure Enclosure Size Knockout atalog Number Pattern Height x Width x Depth x x D E KO No KO in. mm in. mm in. mm Gauge ottom 644 RTH 644 RTH NK 6.00 x 4.00 x x 102 x D 664 RTH 664 RTH NK 6.00 x 6.00x x 152 x D E 864 RTH 864 RTH NK 8.00 x 6.00x x 152 x D E 884 RTH 884 RTH NK 8.00 x 8.00x x 203 x RTH RTH NK 10.00x10.00x x 254 x RTH RTH NK 12.00x12.00x x 305 x RTH 1286 RTH NK 12.00x8.00x x 203 x RTH RTH NK 12.00x10.00x x 254 x RTH RTH NK 12.00x12.00x x 305 x RTH RTH NK 18.00x12.00x x 305 x RTH RTH NK 12.00x12.00x x 305 x RTH RTH NK 18.00x18.00x x 457 x I J RTH RTH NK 24.00x18.00x x 457 x I J RTH RTH NK x x x 610 x I J RTH RTH NK x x x 610 x I J RTH RTH NK x x x 610 x I J RTH NK x x x 762 x Notes: ooper -Line can provide special sizes, finishes and other modifications. onsult the factory for your special requirements. Dimensions are in inches. Millimeters shown are for reference only. Data subject to change without notice. 58

11 Junction oxes Type 3R Hinge over Illustration Sheet E D (32) formed hinge -.25 (6) Front View.25 (6) mounting hole (4PL) Side View padlock hasp knockout area (see table for pattern, see detail for size) ottom View over Style on and larger 1.87 (47) 1.87 (47) D E F 3 /4-1 3 / /4 G H 3/4-1 I J 3 /4-1 K onduit Sizes Knockout Detail Note: See table for applicable knockout pattern. 59

12 Junction oxes Type 3 Screw over - Gasketed Data Sheet pplication Used as wiring boxes, junction and pull boxes Intended for indoor or outdoor use Protects against windblown dust, rain, sleet, external ice formation and dripping non-corrosive liquids Standards UL 508 listed, Type 3 and Type 12 onforms to NEM standard for Type 3 and Type 12 Finish right galvanized finish Zinc-rich coating over all external welds onstruction Enclosure and cover are fabricated from code gauge G-90 grade galvanized steel, (see table, page 61) ll continuous welded seams are finished smooth Enclosure standard without knockouts over is attached with gasketed screws over has a fixed, oil and water resistant gasket #10-32 weldnut is furnished for optional ground lug kit Discount Schedule: 2 Subclass: R0 ccessories Ground lug kit See ccessories section Notes: ooper -Line can provide special sizes, finishes and other modifications. onsult the factory for your special requirements. 60

13 Junction oxes Type 3 Screw over - Gasketed Illustration Sheet and atalog Number (32) gasketed screw (32) Front View Side View Enclosure Enclosure Size Height x Width x Depth ody over atalog Number x x in. mm Gauge Gauge 444 SG 4.00 x 4.00 x x 102 x SG 6.00 x 6.00 x x 152 x SG 8.00 x 6.00 x x 152 x SG 8.00 x 8.00 x x 203 x SG x 8.00 x x 203 x SG x x x 254 x SG x x x 305 x SG 6.00 x 6.00 x x 152 x SG 8.00 x 8.00 x x 203 x SG x x x 254 x SG x x x 254 x SG x x x 305 x SG x x x 305 x SG x x x 406 x SG x x x 457 x SG x x x 406 x SG x x x 610 x SG x x x 305 x SG x x x 508 x SG x x x 508 x SG x x x 610 x SG x x x 610 x SG x x x 762 x SG x x x 914 x

14 Junction oxes Type 3 Weatherproof Screw over Data Sheet pplication Used as wiring boxes, junction and pull boxes Protects against windblown dust, rain, sleet and external ice formation Standards UL 50 listed, Type 3 and Type 12, (unless noted) S 22.2 No. 40 certified, Type 3 and Type 12 onforms to NEM standard for Type 3 and Type 12 Finish Wash and phosphate undercoat NSI 61 gray polyester powder finish ccessories Ground lug kit Touch-up paint See ccessories section onstruction Enclosure and door are fabricated from code gauge steel, (see table, page 63) ll continuous welded seams are finished smooth Enclosure standard without knockouts over is attached with gasketed screws over has flanged sides which secure a fixed, water and ice-resistant gasket #10-32 weld stud is furnished for optional ground lug kit External mounting feet are provided for secure wall mounting Discount Schedule: 2 Subclass: R0 Notes: ooper -Line can provide special sizes, finishes and other modifications. onsult the factory for your special requirements. 62

15 Junction oxes Type 3 Weatherproof Screw over Illustration Sheet and atalog Number D E (32) (32) gasketed screw (32) Front View.31 (8) mounting hole (4PL) Side View Enclosure Enclosure Size Height x Width x Depth x x D E atalog Number in. mm in. mm in. mm Gauge 444 WPS* 4.00 x 4.00 x x 102 x WPS* 6.00 x 4.00 x x 102 x WPS 6.00 x 6.00 x x 152 x WPS 8.00 x 6.00 x x 152 x WPS 8.00 x 8.00 x x 203 x WPS x 8.00 x x 203 x WPS x x x 254 x WPS x x x 305 x WPS x x x 457 x WPS 6.00 x 6.00 x x 152 x WPS 8.00 x 8.00 x x 203 x WPS x x x 254 x WPS x 8.00 x x 203 x WPS x x x 305 x WPS x x x 305 x WPS x x x 305 x WPS x x x 457 x WPS x x x 457 x WPS x x x 610 x WPS x x x 305 x WPS x x x 457 x WPS x x x 610 x WPS x x x 610 x * UL 508 listed, Type 3 and Type 12 63

16 Panel Enclosures Type 1 Small Data Sheet pplication Houses electrical controls and instruments in an environment which does not require oil or dust tight specifications Protects against contact with enclosed equipment Standards UL 50 listed, Type 1 S 22.2 No. 40 certified, Type 1 onforms to NEM standard for Type 1 Finish Wash and phosphate undercoat NSI 61 gray polyester powder finish onstruction Enclosure and cover are fabricated from (16) gauge steel Enclosure body has mounting holes on the back which are accessible with or without the optional panel installed over is secured to the body with a continuous hinge on one side and flush latch on the opposite side Flush latch is designed to operate with either coin or screwdriver #10-32 provisions for mounting optional panel No knockouts Discount Schedule: 2 Subclass: D70 ccessories Panels Terminal blocks Type 1 flush lock Touch-up paint #8-32 self tapping screw (10168) See ccessories section Notes: ooper -Line can provide special sizes, finishes and other modifications. onsult the factory for your special requirements. 64

17 Panel Enclosures Type 1 Small Illustration Sheet and atalog Number Enclosure Enclosure Size Panel Panel Size Height x Width x Depth atalog Number atalog Number x x Height x Width in. mm Solid Perforated in. mm x 6.00 x x 152 x 102 N66P N66PP 4.25 x x x 6.00 x x 152 x 102 N86P N86PP 6.25 x x x 8.00 x x 203 x 102 N88P N88PP 6.25 x x x 8.00 x x 203 x 102 N108P N108PP 8.25 x x x x x 254 x 102 N1010P N1010PP 8.25 x x x x x 254x 102 N1210P N1210PP x x x x x 305 x 102 N1212P N1212PP x x x x x 305 x 102 N1412P N1412PP x x x 6.00 x x 152 x 152 N86P N86PP 6.25 x x x 8.00 x x 203 x 152 N88P N88PP 6.25 x x x 8.00 x x 203 x 152 N108P N108PP 8.25 x x x x x 254 x 152 N1010P N1010PP 8.25 x x x x x 254 x 152 N1210P N1210PP x x x x x 305 x 152 N1212P N1212PP x x x x x 305 x 152 N1412P N1412PP x x x x x 305 x 152 N2012P N2012PP x x x x x 305 x 203 N1212P N1212PP x x x x x 305 x 203 N1412P N1412PP x x 260 continuous hinge (60) panel mount provision (4PL) (60) (28) (28) Front View L.50 (13) cover latch (see Detail).25 (6) mounting hole (4PL) 1.50 (38) 1.81 (46) -.40 (10) Side View optional panel 65 Detail 1.37 (35) flush latch

18 Panel Enclosures Type 1 Medium Data and Illustration Sheet pplication Houses electrical controls and instruments in an environment which does not require oil and dust tight specifications Protects against contact with enclosed equipment Standards UL 50 listed, Type 1 S 22.2 No. 40 certified, Type 1 onforms to NEM standard for Type 1 Finish Wash and phosphate undercoat NSI 61 gray polyester powder finish Optional panels have a white polyester powder finish ccessories Panels Terminal blocks Type 1 flush lock Type 1 security latch inserts Touch-up paint See ccessories section #8-32 self tapping screw (10168) onstruction Enclosure and door are fabricated from code gauge steel, (see table, page 67) Enclosure body has mounting holes on the back which are accessible with or without the optional panel installed Door is secured to the body with a continuous hinge on one side and a flush latch mounted to the opposite side Flush latch is designed to operate with either coin or screwdriver provisions for mounting optional panel No knockouts Discount Schedule: 2 Subclass: D80 14 gauge panel (optional) (76) -**.44 x.81 (11 x 21) mounting hole (2PL) panel mount provision (omit center studs where is less than 30) cover latch (32) L (-*) (see Detail, page 67) (32) panel mount provision (omit center studs where is less than 30) -.56 (14) Front View 1.06 if is 24 or less 1.25 if is 30 or more body stiffener (omit where is less than 30) L Section X-X.44 (11) mounting hole (2PL) X ottom View optional panel X Note: * = 4.50 if is 24 or less * = 5.50 if is 30 or more ** = 5.00 if is 24 or less ** = 7.25 if is 30 or more. Notes: ooper -Line can provide special sizes, finishes and other modifications. onsult the factory for your special requirements. Dimensions are in inches. Millimeters shown are for reference only. Data subject to change without notice. 66

19 Panel Enclosures Type 1 Medium Illustration Sheet and atalog Number Enclosure Enclosure Size Panel Panel Size Height x Width x Depth atalog Number x x Height x Width atalog Number in. mm Gauge Solid Perforated in. mm x x x 305 x W1612-1P W1612-1PP x x x x x 406 x W1616-1P W1616-1PP x x x x x 508 x W1620-1P W1620-1PP x x x x x 406 x W2016-1P W2016-1PP x x x x x 508 x W2020-1P W2020-1PP x x x x x 406 x W2416-1P W2416-1PP x x x x x 508 x W2420-1P W2420-1PP x x x x x 610 x W2424-1P W2424-1PP x x x x x 508 x W3020-1P W3020-1PP x x x x x 610 x W3024-1P W3024-1PP x x x x x 610 x W3624-1P W3624-1PP x x x x x 762 x W3630-1P W3630-1PP x x x x x x 305 x W1612-1P W1612-1PP x x x x x 406 x W2016-1P W2016-1PP x x x x x 508 x W2020-1P W2020-1PP x x x x x 610 x W2024-1P W2024-1PP x x x x x 508 x W2420-1P W2420-1PP x x x x x 610 x W2424-1P W2424-1PP x x x x x 508 x W3020-1P W3020-1PP x x x x x 610 x W3024-1P W3024-1PP x x x x x 762 x W3030-1P W3030-1PP x x x24.00x x 610 x W3624-1P W3624-1PP x x x30.00x x 762 x W3630-1P W3630-1PP x x x24.00x x 610 x W4224-1P W4224-1PP x x x20.00x x 508 x W2420-1P W2420-1PP x x x24.00x x 610 x W3024-1P W3024-1PP x x x20.00x x 508 x W2420-1P W2420-1PP x x x24.00x x 610 x W2424-1P W2424-1PP x x x24.00x x 610 x W3024-1P W3024-1PP x x x30.00x x 762 x W3630-1P W3630-1PP x x (46) 1.37 (35) flush latch Detail 67

20 Panel Enclosures Type 1 Large Data Sheet pplication Houses electrical controls and instruments in an environment which does not require oil and dust tight specifications Protects against contact with enclosed equipment Standards UL 50 Listed, Type 1 S 22.2 No. 40 certified, Type 1 onforms to NEM Standard for Type 1 Finish Wash and phosphate undercoat NSI 61 gray polyester powder finish Optional panels have a white polyester powder finish ccessories Panels Terminal blocks Type 1 flush lock Swing panel kits Window kits Touch-up paint onstruction Enclosure and door are fabricated from (14) gauge steel Enclosure body has mounting holes on the back which are accessible with or without the optional panel installed Door is secured to the body with a heavy-duty continuous hinge on one side and slotted flush latches on the opposite side ody has stiffener for extra rigidity Slotted flush latch is designed to operate with either a coin or a screwdriver provisions for mounting optional panels No knockouts Discount Schedule: 2 Subclass: D80 Notes: ooper -Line can provide special sizes, finishes and other modifications. onsult the factory for your special requirements. 68

Type 12 / 13 Panel Enclosures

Type 12 / 13 Panel Enclosures JI Enclosures Type 12 Lift-Off over.......................................................................................... 90-91 JI Enclosures Type 12 ontinuous Hinge over............................................................................

More information

Type 4X Panel Enclosures

Type 4X Panel Enclosures JI Enclosures Type 4X Lift-Off over...................................................................................... 194-195 JI Enclosures Type 4X Lift-Off over, luminum........................................................................

More information

Type 4 X Panel Enclosures

Type 4 X Panel Enclosures Type 4 X Panel Enclosures JI Enclosures Type 4X Lift-Off over................................................................... 192-193 JI Enclosures Type 4X Lift-Off over, luminum......................................................

More information

Cable & Wire Management

Cable & Wire Management able & ire Management able & ire Management Lay-In ireway Type 1 Screw over... 8-14 Lay-In ireway Type 1 Quick-onnect inge over... 15-20 Lay-In ireway Type 3R EnviroShield... 21-24 Lay-In ireway Type 12...

More information

JIC CONTINUOUS HINGE BOXES

JIC CONTINUOUS HINGE BOXES JIC CONTINUOUS HINGE BOXES Austin JIC Continuous Hinge (JH) boxes are Underwriters Laboratories Listed and are designed for use as electrical junction boxes, terminal wiring boxes, and instruments housing.

More information

Section H Index. www.hubbell-wiegmann.com Data Subject To Change Without Notice OPERATOR INTERFACE

Section H Index. www.hubbell-wiegmann.com Data Subject To Change Without Notice OPERATOR INTERFACE Section H Index H1 W1 Series NEMA 12 onsoles...h2 W9 Series NEMA 12 onsoles...h4 W10 Series NEMA 12 onsoles...h6 W12 Series NEMA 12 onsoles...h8 W14 Series NEMA 12 onsoles...h10 W- Series NEMA 12 onsolets...h12

More information

Locks, Latches, Inserts, & Handles Flush Locks Illustration Sheet and Catalog Number. Type 1 Enclosure Flush Lock. New Flush lock

Locks, Latches, Inserts, & Handles Flush Locks Illustration Sheet and Catalog Number. Type 1 Enclosure Flush Lock. New Flush lock Locks, Latches, Inserts, & Handles Flush Locks Illustration Sheet and Type 1 Panel Enclosure Flush Lock Type 1 Enclosure Flush Lock T1EFL New Flush lock.886 dia. (22) Hole Pattern Detail Flush Locks are

More information

STB Series Enclosures

STB Series Enclosures STB Series Enclosures Features/Applications: The STB series of sheet steel enclosures are designed to meet the requirement for distribution and lighting junction boxes. Available in 14 sizes with standard

More information

1E EJB Junction Boxes Cl. I, Div. 1 and 2, Groups B, C, D

1E EJB Junction Boxes Cl. I, Div. 1 and 2, Groups B, C, D EJB Junction Boxes Cl. I, Div. and 2, Groups B, C, D Cl. II, Div., Groups E, F, G Cl. II, Div. 2, Groups F, G Cl. III NEMA 3, 4, 4X*,, Ex d IIB + H2 T6, IP66 Explosionproof Dust-Ignitionproof Raintight

More information

CABINET OPTIONS AND DESIGNATORS

CABINET OPTIONS AND DESIGNATORS CABINET OPTIONS AND DESIGNATORS Hinges: ~Stainless steel lift off Nuts and Bolts: ~ Stainless steel Hardware: ~ Handles and Corbin locks are stainless steel or zinc plated Windows: ~ Lexan Backboards:

More information

Cluster Box Units. (CBU s) 3300 Series CBU Door Sizes. Fully Integrated Parcel Lockers CLUSTER BOX UNITS FRONT LOADING. continued on pages 7-11

Cluster Box Units. (CBU s) 3300 Series CBU Door Sizes. Fully Integrated Parcel Lockers CLUSTER BOX UNITS FRONT LOADING. continued on pages 7-11 Cluster Box Units (CBU s) continued on pages 7-11 CLUSTER BOX UNITS FRONT LOADING Made of heavy duty aluminum and stainless steel hardware, Salsbury 3300 series U.S.P.S. approved Cluster Box Units (CBU

More information

1036 Parkway Ct. Phone: 770-932-0202 Buford, GA 30518 Fax: 770-945-0041

1036 Parkway Ct. Phone: 770-932-0202 Buford, GA 30518 Fax: 770-945-0041 CONSTRUCTION 1. A. GENERAL 1.A.1. The intent of this specification is to set forth construction and design standards that will result in an installation of modular cabinetry requiring FLUSH OVERLAY CONSTRUCTION.

More information

TABLE OF CONTENTS. Section 1 Type 1 & 3R Enclosures pg. 2-19. Section 2 Type 4 & 12 Enclosures pg. 20-47

TABLE OF CONTENTS. Section 1 Type 1 & 3R Enclosures pg. 2-19. Section 2 Type 4 & 12 Enclosures pg. 20-47 TLE OF CONTENTS Section 1 Type 1 & 3R pg. 2-19 Type 1 & 3R Section 2 Type 4 & 12 pg. 20-47 Section 3 Flange Mounted Disconnect pg. 48-89 Section 4 Type 4, 12 & 13 Oiltight pg. 90-111 Section 5 Pushbutton

More information

FRAME PROFILE MASONRY METAL DOOR FRAME FLUSH MASONRY KD MITER CORNER JOINT. #8 Screw (MS002485) Required on all fire rated KD frames. Bend Tabs.

FRAME PROFILE MASONRY METAL DOOR FRAME FLUSH MASONRY KD MITER CORNER JOINT. #8 Screw (MS002485) Required on all fire rated KD frames. Bend Tabs. FRAME PROFILE MASONRY FLUSH MASONRY KD MITER CORNER JOINT Bend Tabs Head #8 Screw (MS002485) Required on all fire rated KD frames Corner Assembly 2" (50.8) Head Jamb Head Break Away Corner Clip Spot Welds

More information

Data Subject To Change Without Notice STAINLESS STEEL AND NON-METALLIC ENCLOSURES

Data Subject To Change Without Notice STAINLESS STEEL AND NON-METALLIC ENCLOSURES PBSS Series NEMA 4X,12 & 13 (30.5mm) Pushbutton Wall-Mount...E2 PBXD-SS Series NEMA 4X,12 & 13 (30.5mm) Pushbutton Wall-Mount...E4 BN4-SS Series NEMA 4X JIC Clamp Cover Wall-Mount..E6 BN4-CHSS Series NEMA

More information

www.hammondmfg.com General Accessories Hardware

www.hammondmfg.com General Accessories Hardware Heavy Duty Door Clamping Junction Box Padlock Kit Quick Release Clamp Replacement hardware for use on all 1418 and 1447 Series enclosures. Formed heavy gauge stainless steel clamp with stainless steel

More information

PROLINE Go l d Se r i e s. Desk Consoles and Accessories

PROLINE Go l d Se r i e s. Desk Consoles and Accessories Modular Enclosure Systems Application PROLINE Gold Series desk consoles are ergonomically designed for use in either a sitting or standing position. Single-access consoles have a front door and solid back.

More information

Premier & Deluxe 3-Season Room Sliding Glass Door

Premier & Deluxe 3-Season Room Sliding Glass Door DTSSGD-11 Premier & Deluxe 3-Season Room Sliding Glass Door Installation Instructions Screen Door Seal Left Side Track Top Track Assembly Right Side Track Right Side Trim Sliding Glass Door Sliding Screen

More information

SOHOline and SOHO Slimline The SOHOline and SOHO Slimline offer a modular, sturdy and compact design

SOHOline and SOHO Slimline The SOHOline and SOHO Slimline offer a modular, sturdy and compact design SOHOline and SOHO Slimline The SOHOline and SOHO Slimline offer a modular, sturdy and compact design Ideal installation for; Offices Branch Offices Schools Computer Aided Classes Government Offices Hotels

More information

Metallic and Non-Metallic Air Conditioning Disconnects. A Complete Family of. Disconnects with Exclusive Time Saving Features

Metallic and Non-Metallic Air Conditioning Disconnects. A Complete Family of. Disconnects with Exclusive Time Saving Features Metallic and Non-Metallic Air Conditioning Disconnects A Complete Family of Disconnects with Exclusive Time Saving Features Enclosed Molded Case Disconnect Switch Not-Fusible The preferred molded case

More information

Sports and High Mast Lighting Poles Phone: (866) 474-7200 Fax: (817) 924-7049

Sports and High Mast Lighting Poles Phone: (866) 474-7200 Fax: (817) 924-7049 Sports and High Mast Lighting Poles 4 High Mast Lighting Poles General American LitePole offers a raising and lowering system that allows for ease of maintaining the lighting system at ground level. Ideal

More information

Organisational Kitchen Fittings Kitchen Cabinet Fittings

Organisational Kitchen Fittings Kitchen Cabinet Fittings Pull-out wire storage basket Finish: Chrome plated Load capacity: 30 kg Installation depth: 400 mm Version: Runners and baskets separated, designed for wardrobe interiors without doors Type of pull out:

More information

SECTION 08332 COILING COUNTER DOORS. Display hidden notes to specifier. (Don't know how? Click Here)

SECTION 08332 COILING COUNTER DOORS. Display hidden notes to specifier. (Don't know how? Click Here) SECTION 08332 COILING COUNTER DOORS Display hidden notes to specifier. (Don't know how? Click Here) PART 1 GENERAL 1.1 SECTION INCLUDES A. Coiling Metal Counter Doors. B. Coiling Counter Fire Doors. 1.2

More information

Rack Cabinets. Rack Configuration. 19 inch

Rack Cabinets. Rack Configuration. 19 inch Rack Cabinets Rack Configuration 19 inch 19 RACK COMPONENTS FEATURES Hallam Manufacturing s range of 19 inch racks and cabinets for today s data/communications installations are designed and manufactured

More information

Mains. Assembly SCCRs. Voltage ratings. Bus amperages. Branch circuits. Panels. Through-lugs & loadside disconnect. Neutrals. Grounds.

Mains. Assembly SCCRs. Voltage ratings. Bus amperages. Branch circuits. Panels. Through-lugs & loadside disconnect. Neutrals. Grounds. Quik-Spec oordination Panelboard Specifications 11 PELORDS QuikShip ll SQSP configurations of the standard EM 1 enclosure can be specified for shipment within 10 business days of order when specified.

More information

Linear Incline Hook- on Shelves

Linear Incline Hook- on Shelves Linear Incline Hook- on Shelves Tools Required -Plastic Mallet -Phillips head screwdriver -Flat blade screwdriver 1. Assemble the Front Stop to the shelf, using the #10AB x 1-3/4 phillips pan head thread

More information

PVC Nema 4X Electrical Enclosures

PVC Nema 4X Electrical Enclosures 16744 WEST PARK CIRCLE DRIVE CHAGRIN FALLS, OH. 44023 PH ( 440 ) 543-2393 FAX ( 440 )543-2397 www.qubeinc.com PVC Nema 4X Electrical Enclosures STANDARD TERMS VERBAL ORDERS ARE NOT ACCEPTED : Because of

More information

James M. Pleasants Company

James M. Pleasants Company James M. Pleasants Company SUBMITTAL DATA GAINESVILLE MECHANICAL DECEMBER 20, 2013 PROJECT: GSU: J-183 HUMANITIES LAW BLDG. QUOTE NO:12116 ENGINEER: STEVENS & WILKINSON GASKETED PLATE HEAT EXCHANGER Tag:

More information

DCF Optimized Rack System

DCF Optimized Rack System Integrated Cabinet Solutions For Business-Critical Continuity DCF Optimized Rack System User Manual IMPORTANT SAFETY GUIDELINES SAVE THESE INSTRUCTIONS This manual contains important instructions that

More information

CUBE-iT PLUS CABINET SYSTEM

CUBE-iT PLUS CABINET SYSTEM P R O D U T D T S H E E T UE-iT PLUS INET SYSTEM K E Y F E T U R E S Swing-out cabinet body enables easy access to the rear of installed equipment. Rear panel is pre-punched with knockouts for 1/2", 3/4",

More information

BERTHOLD ELECTRIC GENERATOR CONNECTION CABINET

BERTHOLD ELECTRIC GENERATOR CONNECTION CABINET BERTHOLD ELECTRIC GENERATOR CONNECTION CABINET Berthold Electric Company s Generator Connection Cabinet provides a quick and convenient station to connect a portable generator to a facility s main service

More information

Installation Instructions

Installation Instructions READ BEFORE INSTALLING UNIT For Slider Casement Air Conditioners To avoid risk of personal injury, property damage, or product damage due to the weight of this device and sharp edges that may be exposed:

More information

Installation Instructions

Installation Instructions READ BEFORE INSTALLING UNIT For Through-the-Wall Air Conditioners To avoid risk of personal injury, property damage, or product damage due to the weight of this device and sharp edges that may be exposed:

More information

The Manitoba Water Services Board SECTION 027110 Standard Construction Specifications September 2013 Page 1 of 12

The Manitoba Water Services Board SECTION 027110 Standard Construction Specifications September 2013 Page 1 of 12 September 2013 Page 1 of 12 Part 1 General 1.1 DESCRIPTION OF WORK.1 The work shall consist of the supply and construction of a chain link fence, barb wire fences or mesh fences as shown on the Plans or

More information

INSTALLATION INSTRUCTIONS 24" (61.0 CM) ELECTRIC SINGLE AND DOUBLE BUILT-IN OVEN

INSTALLATION INSTRUCTIONS 24 (61.0 CM) ELECTRIC SINGLE AND DOUBLE BUILT-IN OVEN INSTLLTION INSTRUTIONS 24" (61.0 M) LTRI SINGL N OUL UILT-IN OVN Table of ontents UILT-IN OVN SFTY... 1 INSTLLTION RQUIRMNTS... 2 Tools and Parts... 2 Location Requirements... 2 lectrical Requirements...

More information

INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks

INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks Securitron Magnalock Corp. www.securitron.com ASSA ABLOY, the global leader Tel 800.624.5625 techsupport@securitron.com in door opening solutions INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate

More information

Scepter PVC Molded Junction Boxes

Scepter PVC Molded Junction Boxes Scepter PVC Molded Junction Boxes TM ELECTRICAL SYSTEMS PVC MOLDED JUNCTION BOXES 4" to 12" Fully Certified: NEMA, UL & CSA We build tough products for tough environments Standing Still is Not an Option.

More information

FAIRFIELD INDUSTRIES INC.

FAIRFIELD INDUSTRIES INC. FAIRFIELD INDUSTRIES INC. v NEW PRICE SCHEDULE 4/1/201 SUPERSEDES 4/1/11 SPILL CONTAINMENT And STREET ACCESS MANHOLES for UNDERGROUND And ABOVEGROUND TANKS SPILL CONTAINMENT MANHOLES MONITOR WELL SERIES

More information

WHI 90-Minute Rated Veneered Door Frame Installation Instructions

WHI 90-Minute Rated Veneered Door Frame Installation Instructions No. 940-03-10 INSTALLATION INSTRUCTIONS 90 MINUTE RATED VENEERED DOOR FRAME DOOR REQUIREMENTS: Consult the door manufacturer to make sure that the doors are qualified for the hardware to be installed,

More information

Low Voltage 480V Switchgear

Low Voltage 480V Switchgear Low Voltage 480V Switchgear General Description Low Voltage metal-enclosed switchgear is used in electric power distribution systems for the control and protection of circuits and equipment. The switchgear

More information

Aluminium Standard. Technical Data. Included in delivery

Aluminium Standard. Technical Data. Included in delivery luminium Standard UL / cul Robust aluminium enclosure for mechanical engineering and automation technology Fixing options for s and mounting plates Usable in wide temperature area Technical ata aterial:

More information

GEH6290. Mechanism Circuit Breaker. Handle Operating Mechanism Cat. No. Type NEMA 1, 3R, 12, 13 NEMA 4/4X Cat. No. Cat. No. Series Instruction

GEH6290. Mechanism Circuit Breaker. Handle Operating Mechanism Cat. No. Type NEMA 1, 3R, 12, 13 NEMA 4/4X Cat. No. Cat. No. Series Instruction GEH6290 g Cable Operator Mechanisms for E150, SE150, SF250, and SG600 Spectra RMS Circuit Breakers Type SCH1/1X, SCH2/2X Flange-Mounted Handle Assemblies, Cable Series SC3L SC10L and Type SC0M1A, SCOM1EF,

More information

Steel Meter Boxes & Meter Box Repairs Electric & Gas Design Manufacture Supply

Steel Meter Boxes & Meter Box Repairs Electric & Gas Design Manufacture Supply since 1895 Steel Meter Boxes & Meter Box Repairs Electric & Gas Design Manufacture Supply British Manufacturer Ritherdon design all the steel products detailed within this brochure at their factory in

More information

Scepter PVC Molded Junction Boxes

Scepter PVC Molded Junction Boxes Scepter PVC Molded Junction Boxes ELECTRICAL SYSTEMS PVC MOLDED JUNCTION BOXES 4" to 12" We build tough products for tough environments Standing Still is Not an Option. We re proud to introduce the NEW

More information

IT-SOLUTIONS.

IT-SOLUTIONS. IT-SOLUTIONS Well conceived Haewa Group has gained a strong profile as an innovative and competent supplier for the machinery, systems, electrical and electronic industries, well beyond European geographic

More information

ELECTRIC METERING COMMERCIAL & INDUSTRIAL

ELECTRIC METERING COMMERCIAL & INDUSTRIAL ELECTRIC METERING COMMERCIAL & 1.0 INDEX 1.0 INDEX 2.0 SCOPE 3.0 GENERAL REQUIREMENTS 4.0 METER LOCATIONS 5.0 UNDERGROUND TERMINATIONS 6.0 METERING TRANSFORMER ENCLOSURES 7.0 SINGLE CUSTOMER METER INSTALLATIONS

More information

Section 10 Electric Switchboards: 0 Through 600 Volts

Section 10 Electric Switchboards: 0 Through 600 Volts Section 10 Electric Switchboards: 0 Through 600 Volts 10.1. Scope This section provides specific dimensions and details for service and meter equipment that is assembled by the manufacturer in freestanding,

More information

Saturn Cutoff. Order Code: Pole Order Code: - - - Series Height Finish Options. Customer: Date: Project: Qty: Type: SAC Saturn Cutoff SAC

Saturn Cutoff. Order Code: Pole Order Code: - - - Series Height Finish Options. Customer: Date: Project: Qty: Type: SAC Saturn Cutoff SAC Date: Customer: Project: Type: Qty: Saturn Cutoff Order Code: SAC - - - - - - - - SAC Series SAC Saturn Cutoff Pole Order Code: - - - Series Height Finish Options Optics R Type II Distribution R Type V

More information

Rittal s Comprehensive Family Of... NETWORK RACK SOLUTIONS

Rittal s Comprehensive Family Of... NETWORK RACK SOLUTIONS Rittal s Comprehensive Family Of... NETWORK RACK SOLUTIONS STANDARD & ECONOMICAL BasicRack A complete low-cost, high-quality basic equipment management system. Design Six web channel holes per side allow

More information

March 14, 2007. Installation of Bay, Bow and Garden Windows

March 14, 2007. Installation of Bay, Bow and Garden Windows March 14, 2007 Re: Installation of Bay, Bow and Garden Windows Attached are the Atrium Companies, Inc recommendation for the installation of bay, bow and garden windows. These instructions were developed

More information

TSLOTS Hardware 06:02

TSLOTS Hardware 06:02 06 TSLOTS HARDWARE This section includes everything you need to build panels and doors for guarding, bi-fold doors, sliding doors or enclosures. If you need something to complete a project and we don't

More information

PART 1 GENERAL 1.1 SECTION INCLUDES

PART 1 GENERAL 1.1 SECTION INCLUDES J-1 Section 09110 Long Form Specification INTERIOR METAL STUD FRAMING This section includes lightweight, usually 0.036 inch (0.9 mm) thick or lighter, non-axial load bearing metal stud framing including

More information

SECTION 26 05 49 VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS

SECTION 26 05 49 VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS SECTION 26 05 49 VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS PART 1 - GENERAL 1.1 SUMMARY A. This Section includes seismic restraints and other earthquake-damage-reduction measures for electrical

More information

Rack installation instructions

Rack installation instructions Rack installation instructions Review the documentation that comes with the rack cabinet for safety and cabling information. Before you install the server in a rack cabinet, review the following guidelines:

More information

Load Centers. GE load centers deliver the highest quality and convenience.

Load Centers. GE load centers deliver the highest quality and convenience. GE Load Centers GE load centers deliver the highest quality and convenience. Load Centers GE load centers lower your costs by making installation faster and easier and by increasing application flexibility.

More information

Parts List. Safety Information. Additional Considerations. Retractable Security Cover Kit. Rocky Roller Kit

Parts List. Safety Information. Additional Considerations. Retractable Security Cover Kit. Rocky Roller Kit Parts List Retractable Security Cover Kit 3" PVC pipe with (4) 7'4" lengths of track (longer pools will have additional track pieces) Leading edge Optional cover pump (for outdoor installations) Rocky

More information

Unpacking, Installation, and Customization

Unpacking, Installation, and Customization Unpacking, Installation, and Customization NetShelter WX Enclosure AR100 AR100HD Contents Unpacking... 1 How to Unpack the Enclosure............................... 1 Please Recycle..........................................

More information

Secure your IT equipment with confidence... secure with NetClosure

Secure your IT equipment with confidence... secure with NetClosure Secure your IT equipment with confidence... secure with NetClosure SERVER CABINETS NetClosure s REM Series Server Cabinet is the ultimate solution designed and engineered for demanding data center environments.

More information

All-Season Sunroom Sliding Glass Door Installation Instructions

All-Season Sunroom Sliding Glass Door Installation Instructions ASRESGD-08 All-Season Sunroom Sliding Glass Door Installation Instructions Panel Frame Door Frame Left Side Foam Insulator IE241 H Bar Assembly Door Frame Top Track Panel Frame Door Frame Right Side Stationary

More information

Black Sand Bronze We are a creative team based in New Zealand, we have been designing and making things for over 20 years, from the small scale of gold smithing to large civic projects, our passion is

More information

Installation Instructions For Slider Casement Air Conditioners

Installation Instructions For Slider Casement Air Conditioners Installation Instructions For Slider Casement Air Conditioners NOTE: These instructions describe installation in a typical wood framed window with a wood SLIDE-BY sash, or installation in a metal CASEMENT

More information

19 DYNAmax Free Standing Server C A B I N E T s

19 DYNAmax Free Standing Server C A B I N E T s 9 DYNAmax Free Standing Server C A B I N E T s 9 DYNAmax Free Standing Server Cabinets FAMILY W=mm and W=800mm DYNAmax Series Free Standing Server Cabinets DYNAmax series Servering Enclosures, provide

More information

19 DYNAmax Free Standing Server C A B I N E T s

19 DYNAmax Free Standing Server C A B I N E T s 9 DYNAmax Free Standing Server C A B I N E T s 9 DYNAmax Free Standing Server Cabinets FAMILY W=600mm and W=800mm DYNAmax Series Free Standing Server Cabinets DYNAmax series Servering Enclosures, provide

More information

YASKAWA. Protective Enclosures for Yaskawa AC Drives Application Note 1 2 3 4 5 6 7 8 A B C D DOCUMENT NO. AN.AFD.27

YASKAWA. Protective Enclosures for Yaskawa AC Drives Application Note 1 2 3 4 5 6 7 8 A B C D DOCUMENT NO. AN.AFD.27 YASKAWA Protective Enclosures for Yaskawa AC Drives Application Note 1 2 3 4 5 6 7 8 A B C D DOCUMENT NO. AN.AFD.27 E 2 YASKAWA Application Note AN.AFD.27 Protective Enclosures for Yaskawa AC Drives 1

More information

Oceanscience Cable Chimp II Cableway ROV System User Guide and Warranty

Oceanscience Cable Chimp II Cableway ROV System User Guide and Warranty Oceanscience Cable Chimp II Cableway ROV System User Guide and Warranty Page 1 Table of Contents Introduction Page 3 Overview Page 3 Setup and Operation Page 5 Remote Control Page 6 Power Management Page

More information

Customized Server Cabinets

Customized Server Cabinets GOING GREEN WITH CUSTOMIZABLE CABINETS AND RACKS Designed to provide industry leading airflow, CyrusOne s cabinets and rack solutions promote optimal cooling and contribute to reduced power consumption.

More information

Learning Module 13: Panelboards and Switchboards. 101 Basic Series

Learning Module 13: Panelboards and Switchboards. 101 Basic Series Learning Module 13: Panelboards and Switchboards 101 Basic Series What You Will Learn We ll step through each of these topics in detail: Introduction 4 Definitions 4 Similarities Between Panelboards and

More information

BID PACKAGE ATHLETIC LOCKER REPLACEMENT PUTNAM HIGH SCHOOL 152 WOODSTOCK AVENUE PUTNAM, CONNECTICUT OWNER: OWNER CONTACT:

BID PACKAGE ATHLETIC LOCKER REPLACEMENT PUTNAM HIGH SCHOOL 152 WOODSTOCK AVENUE PUTNAM, CONNECTICUT OWNER: OWNER CONTACT: BID PACKAGE PUTNAM HIGH SCHOOL 152 WOODSTOCK AVENUE PUTNAM, CONNECTICUT ATHLETIC LOCKER REPLACEMENT OWNER: PUTNAM PUBLIC SCHOOLS 126 CHURCH STREET PUTNAM, CONNECTICUT 06260 OWNER CONTACT: NANCY T. COLE

More information

MCC Ratings. Voltage Rating

MCC Ratings. Voltage Rating MCC Ratings In addition to the various ratings of individual components used in motor control centers, the overall ratings of the motor control center must also be considered. Voltage Rating Motor control

More information

Low Voltage Transformers Sealed, General Purpose, Dry Type

Low Voltage Transformers Sealed, General Purpose, Dry Type Low Voltage Transformers Sealed, General Purpose, Dry Type Catalog 7400CT9601R4/08 08 Class 7400 CONTENTS Description..............................................Page Introduction.................................................

More information

ARTS AND CRAFTS 10.1.0. 5410 (open) 5412 (doors) H : 84" Tote Tray Storage. Damp Storage. Tote Tray Storage. Notebook Board Storage, Doors

ARTS AND CRAFTS 10.1.0. 5410 (open) 5412 (doors) H : 84 Tote Tray Storage. Damp Storage. Tote Tray Storage. Notebook Board Storage, Doors Drawing Board Storage, Open Drawing Board Storage, Doors Drawing Board Storage Notebook Storage, Open 1670 D : 23.25" holds 32 drawing boards 1 shelf, adjustable on 1¼" increments maximum board height

More information

Installation Manual For FE26 Iron Railing. Call for Installation Support. Extra Screws Included

Installation Manual For FE26 Iron Railing. Call for Installation Support. Extra Screws Included Installation Manual For FE Iron Railing Call 1-800-335-5909 for Installation Support Extra Screws Included Fortress Fe 2 Post Mounting Applications (USA) It is the responsibility of the installer to meet

More information

HPE 10000 G2 Series Rack Options Installation Guide

HPE 10000 G2 Series Rack Options Installation Guide HPE 10000 G2 Series Rack Options Installation Guide Abstract This document is for the person who installs racks and rack products. This procedure is performed only by trained personnel. Hewlett Packard

More information

AMPSEAL* Automotive Plug Connector and Header Assembly

AMPSEAL* Automotive Plug Connector and Header Assembly AMPSEAL* Automotive Plug Connector and Header Assembly Application Specification 24 SEP 97 Rev E All dimensions are given in millimeters unless otherwise specified. All dimensional tolerances are +0.2

More information

RAIN COLLECTOR S HELF MANUAL

RAIN COLLECTOR S HELF MANUAL RAIN COLLECTOR S HELF MANUAL The Rain Collector Shelf provides a good mounting support for your Rain Collector II. The Rain Collector Shelf is designed to be attached to Davis Sensor Mounting Arm, and

More information

A D D E N D U M # 3 QUESTIONS FROM BIDDERS: DATE: November 5, 2012. All Bidders. Jenne dos Santos, CBI Consulting Inc. City of Chelsea, MA

A D D E N D U M # 3 QUESTIONS FROM BIDDERS: DATE: November 5, 2012. All Bidders. Jenne dos Santos, CBI Consulting Inc. City of Chelsea, MA Page 1 of 10, Addendum No. 3 Temporary Garage Structure City of Chelsea, MA November 5, 2012 CBI Job No.: 12055-A A D D E N D U M # 3 DATE: November 5, 2012 TO: FROM: PROJECT: All Bidders Jenne dos Santos,

More information

Corrosion-Resistant Enclosures CR-30 CR-1 CR-82 CR-120 CR-20

Corrosion-Resistant Enclosures CR-30 CR-1 CR-82 CR-120 CR-20 Isolating critical controls from harsh environments is a job no one performs better than Hoffman. Select from a wide variety of materials, sizes, and designs to meet your specifications. From food and

More information

2. The Laboratory Fume Hood Specification Catalog Select the style and size hoods appropriate for your layout and laboratory use.

2. The Laboratory Fume Hood Specification Catalog Select the style and size hoods appropriate for your layout and laboratory use. TABLE OF CONTENTS How to Specify... 3 Introduction to Fisher Hamilton Stainless Steel Laboratory Casework... 4 5 Stainless Steel Casework Options Menu... 6 Base Cabinets... 7 17 Sitting Height Cabinets...

More information

INC Flexi-Sorb. Versatile Flexible Easy To Install Durable Good Noise Reduction Economical. Typical Applications

INC Flexi-Sorb. Versatile Flexible Easy To Install Durable Good Noise Reduction Economical. Typical Applications INC Flexi-Sorb Noise Control Curtain System Versatile Flexible Easy To Install Durable Good Noise Reduction Economical Our Flexi-Sorb noise control curtain product line consists of flexible, durable acoustical

More information

Integral Kit Instructions

Integral Kit Instructions Integral Kit Instructions For Fisher & Paykel Cabinet widths of 525, 635, 680, 790 mm wide For curved door Models Series B, C, D & G Manual 814980 Updated August 2008 IMPORTANT If your refrigerator has

More information

Powerware Enclosure Solutions Product Focus

Powerware Enclosure Solutions Product Focus Powerware Enclosure Solutions Product Focus Powerware Enclosures IT availability and reliability are critical corporate issues in today s demanding, mission-critical environments. For this reason, it is

More information

Network Equipment Racks & Accessories

Network Equipment Racks & Accessories 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 01 33 02 34 03 35 04 36 05 37 06 38 07 39 08 40 09 41 10 42 11 43 12 13 14 15 16 17 18 19 20 21 22 23 24

More information

Cooktop Low-Profile Ventilation Hoods

Cooktop Low-Profile Ventilation Hoods INSTALLATION GUIDE Cooktop Low-Profile Ventilation Hoods Contents Wolf Cooktop Low-Profile Ventilation Hoods........ 3 Cooktop Low-Profile Hood Specifications.......... 4 Cooktop Low-Profile Hood Installation............

More information

Installation and Maintenance Instructions for Switch Fuse, Fuse Switch and associated busbar chambers.

Installation and Maintenance Instructions for Switch Fuse, Fuse Switch and associated busbar chambers. Document No. 79001865A RevA Installation and Maintenance Instructions for Switch Fuse, Fuse Switch and associated busbar chambers. 1 Switch Fuse and Switch Fuse Disconnectors 1.1 Installation Instructions

More information

GUE, GUB Junction Boxes

GUE, GUB Junction Boxes E GUE, GUB Junction Boxes Cl. I, Div. & 2, Groups B, C, D Cl. II, Div., Groups E, F, G Cl. II, Div. 2, Groups F, G Cl. III NEMA 4*, BCD, 9EFG Ex d IIC T6, IP66 Ex d IIC, IP66, ATEX certified Explosionproof

More information

19" Data Racks. Adjustable feet To compensate for uneven floors and assure great stability all feet can be up to 20 mm adjusted.

19 Data Racks. Adjustable feet To compensate for uneven floors and assure great stability all feet can be up to 20 mm adjusted. 19" Data Racks Attractive design and high quality are characteristic. Basic framework is welded from multiple bent metal plate, which assures great rigidity suitable for heavier equipment. All profile

More information

TS93 EMR T/PT/TDE. Surface applied door closer

TS93 EMR T/PT/TDE. Surface applied door closer TS EMR T/PT/TDE Surface applied door closer Installation instructions: Pull side track mount door closer with smoke detector (EMR T) Push side track mount door closer with smoke detector (EMR PT) Double

More information

MAST ARMS & POLES. Ornamental Pole Top & Bases

MAST ARMS & POLES. Ornamental Pole Top & Bases Ornamental Pole Top & Bases Pelco s decorative pole top and bases help make the traffic signal aesthetically pleasing to the eye. Available for various pole diameters and multiple finish options. Ornamental

More information

SECTION 08360 SECTIONAL OVERHEAD DOORS 521 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS

SECTION 08360 SECTIONAL OVERHEAD DOORS 521 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS SECTION 08360 SECTIONAL OVERHEAD DOORS 521 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS Display hidden notes to specifier by using Tools / Options / View / Hidden Text. On newer versions of Microsoft Word

More information

K. D. FRAME ASSEMBLY FOR CLOSED STEEL STUD WALLS...Ins 10. FRAME INSTALLATION DETAILS FOR CLOSED STEEL STUD WALLS...Ins 11

K. D. FRAME ASSEMBLY FOR CLOSED STEEL STUD WALLS...Ins 10. FRAME INSTALLATION DETAILS FOR CLOSED STEEL STUD WALLS...Ins 11 K. D. FRAME ASSEMBLY FOR MASONRY WALLS...........................Ins 2 FRAME INSTALLATION DETAILS FOR MASONRY WALLS......................Ins 3 INSTALLING EXISTING MASONRY WALL ANCHORS IN FRAME..................Ins

More information

SECTION STANDING SEAM METAL ROOFING

SECTION STANDING SEAM METAL ROOFING PART 1 - GENERAL 1.1 DESCRIPTION SECTION 07 41 13 SPEC WRITER NOTES: 1. Use this section only for NCA projects. 2. Use for roofing sloped 1 in 4 (3 in/ft) or greater. 3. Delete between // // if not applicable

More information

Installation Manual. Toilet Partitions, Dressing Compartments & Shower Stalls

Installation Manual. Toilet Partitions, Dressing Compartments & Shower Stalls Installation Manual Toilet Partitions, Dressing Compartments & Shower Stalls Metpar Corp 95 State Street, Westbury, New York, USA, 11590 Tel: 516-333-2600 Fax: 516-333-2618 Internet: http://www.metpar.com

More information

SERVER ROOM CABINET INSTALLATION CONCEPTS

SERVER ROOM CABINET INSTALLATION CONCEPTS SERVER ROOM CABINET INSTALLATION CONCEPTS SERVER ROOM CABINET INSTALLATION CONCEPTS SERVER ROOM CABINET INSTALLATION CONCEPTS ZPAS 169 EXAMPLES OF SERVER ROOMS PROJECTS WITH ZPAS CABINETS Data Box in the

More information

MGB Chrome Bumper Conversion

MGB Chrome Bumper Conversion MGB Chrome Bumper Conversion Installation Instructions For 1974 1/2-1980 MGB This kit requires cutting, welding, and painting. Professional installation recommended. Note: Every MGB body is slightly different

More information

LCN 2030 SERIES FEATURES CONCEALED (IN 1 3/4 HEADER) MOUNTING. The concealed 2030 Series. PACER is a heavy duty closer. designed to fit in a narrow,

LCN 2030 SERIES FEATURES CONCEALED (IN 1 3/4 HEADER) MOUNTING. The concealed 2030 Series. PACER is a heavy duty closer. designed to fit in a narrow, CONCEALED (IN 1 3/4 HEADER) MOUNTING The concealed 2030 Series PACER is a heavy duty closer designed to fit in a narrow, minimum 1 3/4 aluminum transom. The single lever arm and roller assembly provide

More information

F-Series Camera Mounting Accessories

F-Series Camera Mounting Accessories F-Series Camera Mounting Accessories Document Number: 427-0462-00-12 Version: 100 Issue Date: September 2010 2010. All rights reserved worldwide. FLIR Commercial Systems, Inc. 70 Castilian Drive Goleta,

More information

SECTION 32 31 00 EXPANDED METAL FENCING Meets Buy American Procurement

SECTION 32 31 00 EXPANDED METAL FENCING Meets Buy American Procurement PART 1 GENERAL SECTION 32 31 00 EXPANDED METAL FENCING Meets Buy American Procurement 1.1 SUMMARY A. Section Includes 1. Supply and install all materials and accoutrements required for the installation

More information

ELECTRIC UTILITY SERVICE EQUIPMENT REQUIREMENTS COMMITTEE, EUSERC

ELECTRIC UTILITY SERVICE EQUIPMENT REQUIREMENTS COMMITTEE, EUSERC ELECTRICAL SERVICE REQUIREMENTS ELECTRIC UTILITY SERVICE EQUIPMENT REQUIREMENTS COMMITTEE, EUSERC TABLE OF CONTENTS TITLE SECTION NO. List of Approved Electric Utility Service Equipment Requirements Committee

More information

ROLLING CURTAIN DOOR INSTALLATION, MAINTENANCE & PARTS MANUAL WINDLOCK MODEL 955WL

ROLLING CURTAIN DOOR INSTALLATION, MAINTENANCE & PARTS MANUAL WINDLOCK MODEL 955WL ROLLING CURTAIN DOOR INSTALLATION, MAINTENANCE & PARTS MANUAL WINDLOCK MODEL 955WL Read manual thoroughly prior to installing door. Rolling steel doors are large, heavy objects that move with the help

More information

Installation Manual Box Rail Series

Installation Manual Box Rail Series Installation Manual Box Rail Series INTRODUCTION THANK YOU for purchasing Real Sliding Hardware. Our hardware will add a stunning accent to your living environment and maximize its space. It is made with

More information