Permanent Pressure Loss Comparison Among Various Flowmeter Technologies White Paper
|
|
|
- Eugenia Lamb
- 9 years ago
- Views:
Transcription
1 Among Various Flowmeter Technologies White Paper Page 1 of 9
2 White Paper By Stephen A. Ifft Mechanical Engineer McCrometer, Inc. Among Various Flowmeter Technologies Abstract This paper explores the issue of permanent pressure loss through various types of flow metering technologies. Of particular interest is the. The flowmeter is a differential pressure device produced by McCrometer, Hemet, California, USA. By design, the measures differential pressure created by a cone positioned in the center of the pipe. The open area through which the fluid passes is stretched over the edge of the cone. This annular space appears to constrict flow dramatically compared to other metering technologies. This paper compares the permanent pressure loss among meters in a typical application. Introduction The is a patented flowmeter made by McCrometer. With its unique geometry, the creates a differential pressure signal that is proportional to the square of the flowrate. This differential pressure signal is then measured by a secondary device that converts the analog pressure signal to an electronic signal, usually a standard 4-20 ma current signal. The electronic signal can then be used to calculate flowrate, mass rate, etc. using tertiary devices. One typical question regarding the is the amount of permanent pressure loss to be expected through the meter in the application. On first look, the cone appears to occupy an inordinate amount of space in the pipeline, and thus constrict the flow greatly. In reality, the cone restricts the flow very little. Several factors contribute to allowing the to measure flowrate very accurately without significant permanent pressure loss. One method to compare differential pressure meters is by the beta ratio. The beta ratio is the ratio of the smallest open area to the largest open area in the meter. In traditional differential pressure meters, this is usually the ratio of the diameter of the constriction to the diameter of the pipe. This is identical to the ratio of the areas mentioned earlier. s also have beta ratios that share the same area definition. Since the does not have a central opening, the beta ratio is calculated in a slightly different manner. See. figure 1. Page 2 of 9
3 If a meter has a beta ratio of, for example, 0.65, this means that 42% of the pipe area is still open at the largest constriction (0.65 x 0.65 = 0.42). This applies to all differential pressure flowmeters, including the. A typical method to measure the permanent pressure loss in a differential pressure flowmeter is to state a percentage of the differential pressure created at a given flowrate. For example, a differential pressure meter may state a 50% permanent pressure loss of differential pressure created. If the maximum differential pressure created by the meter is 10 kpa, the permanent pressure loss at that flowrate is 5 kpa. If the flow decreased and the differential pressure becomes smaller, the permanent pressure loss will become smaller. The percentage of differential pressure permanently lost can be graphed as a relationship of beta ratio. See figure 2. The is positioned between the orifice and the nozzle curves. This, however, is not a true comparison between the permanent pressure loss expected through the meters because the requires less differential pressure to remain accurate and repeatable. This is possible because of the stable and controlled differential pressure signal created by the cone. A true comparison would be to compare the actual permanent pressure loss expected through various meters for a given application. Application Comparison An application was chosen to compare the permanent pressure loss through the following meters: 1. based on information from McCrometer 2. Plate 3. Flow 4. Venturi with 15 o exit angle 5. Venturi with 7 o exit angle 6. Turbine 7. Vortex based on information from Miller 1 8. Coriolis 9. Vortex based on information from Foxboro Co. 10. Coriolis based on information from MicroMotion Co. Page 3 of 9
4 The application parameters were as follows: Application Information: Nominal Line Size: 3 inch Fluid: Water Temperature: 15 o C Pressure: 5 barg Density: kg/m 3 Viscosity: cp Flowrate: 1145 LPM Meter Sizing Each differential pressure meter was sized according to standard specifications from McCrometer, Miller 1 and ISO The following chart shows specifics for each differential pressure meter: Venturi Beta ratio: Max. DP (kpa): Cf (Cd): The has a recommended differential pressure (12.3 kpa) that is half what is recommended for all other differential pressure meters (24.6 kpa). The orifice was sized with the largest suggested beta ratio to keep the differential pressure as low as possible. At the largest beta ratio, the differential pressure created exceeded the recommended by almost twice. All other meters were selected according to line size alone. Standard meter specifications were used for the turbine and vortex. Other specific meters were selected based on manufacturer s recommendations and the following model numbers were used: MicroMotion Coriolis I/A Series E83 CMF300M In all cases the line size remained 3 diameter nominal. Results By comparing permanent pressure loss for a given application, an accurate comparison can be drawn between metering technologies. See figure 3 for a graphical representation of permanent pressure loss through these meters over a 10:1 flow turndown. See figure 4 for a graph of maximum loss through each meter at maximum flowrate. MicroMotion data appears only in figure 4 due to lack of turndown information from the manufacturer. Page 4 of 9
5 To summarize, the meters ranked in the following order according to permanent pressure loss: 1. Venturi with 7 o exit angle Venturi with 15 o exit angle 4. Flow 5. Vortex 6. Turbine Plate 9. MicroMotion Coriolis 10. Further Results A similar comparison was completed on a 2 line size to compare the effect of line size under generally similar conditions. The ranking changed slightly: 1. Venturi with 7 o exit angle Venturi with 15 o exit angle 4. Flow 5. Vortex 6. Turbine Plate MicroMotion Coriolis See figures 5 and 6 for graphical comparisons. Page 5 of 9
6 Figure 1 Permanent Pressure Loss Differential Pressure Meters % of DP Beta Ratio Venturi 15 Venturi 7 Data from R. W. Miller "Flow Measurement Engineering Handbook" Second Edition, McGraw-Hill, Figure 2 Page 6 of 9
7 3" 1145 LPM Permanent Pressure Loss (kpa) Turbine Vortex Venturi 15 o Venturi 7 o Flowrate (LPM) Data from R.W. Miller, Flow Measurement Engineering Handbook, Second Edition, McGraw-Hill, 1989, unless otherwise noted by company name. Figure 3 35 Maximum Loss: 3" 1145 LPM Permanent Pressure Loss (kpa) Venturi 15 Venturi 7 Turbine Vortex MicroMotion Coriolis 0 Meter Types Data from R. W. Miller "Flow Measurement Engineering Handbook" Second Edition, McGraw-Hill, 1989, unless otherwise noted by company name. Figure 4 Page 7 of 9
8 Permanent Pressure Loss (kpa) " 527 LPM Turbine Vortex Venturi 15 o Venturi 7 o Flowrate (LPM) Data from R.W. Miller, Flow Measurement Engineering Handbook, Second Edition, McGraw-Hill, 1989, unless otherwise noted by company name. Figure 5 Maximum Loss: 2" 527 LPM 50 MicroMotion Coriolis Permanent Pressure Loss (kpa) Turbine Vortex Venturi 15 Venturi 7 0 Meter Types Data from R. W. Miller "Flow Measurement Engineering Handbook" Second Edition, McGraw-Hill, 1989, unless otherwise noted by company name. Figure 6 Page 8 of 9
9 References 1. Miller, R. W., Flow Measurement Engineering Handbook, Second Edition, McGraw-Hill, International Standard ISO 5167, Measurement of fluid flow by means of orifice plates, nozzles and venturi tubes inserted in circular cross-section conduits running full., Ref. No. ISO (E). Page 9 of 9
Custody Transfer Measurement. with the V-Cone Flowmeter
Custody Transfer Measurement with the V-Cone Flowmeter Stephen A. Ifft McCrometer Inc. Hemet, California, USA Abstract This paper will discuss the approval of the McCrometer V-Cone flowmeter for custody
FLOW MEASUREMENT 2001 INTERNATIONAL CONFERENCE DERIVATION OF AN EXPANSIBILITY FACTOR FOR THE V-CONE METER
FLOW MEASUREMENT 200 INTERNATIONAL CONFERENCE DERIVATION OF AN EXPANSIBILITY FACTOR FOR THE V-CONE METER Dr D G Stewart, NEL Dr M Reader-Harris, NEL Dr R J W Peters, McCrometer Inc INTRODUCTION The V-Cone
V-Cone, An Alternative to Orifice Meter in Wet Gas Applications
V-Cone, An Alternative to Orifice Meter in Wet Gas Applications Stephen A. Ifft McCrometer Inc. Hemet, California, USA Abstract This paper will discuss the use of the V-Cone differential pressure flowmeter
Advanced Differential Pressure Flowmeter Technology V-CONE FLOW METER TECHNICAL BRIEF
Advanced Differential Pressure Flowmeter Technology V-CONE FLOW METER TECHNICAL BRIEF Table of Contents Section 1 - General Introduction 1.1 1 Principles Of Operation 1.2 1 Reshaping The Velocity Profile
Aeration Air & Digester Gas Flow Metering Using Thermal Mass Technology. HWEA 2011 Conference Craig S. Johnson
Aeration Air & Digester Gas Flow Metering Using Thermal Mass Technology HWEA 2011 Conference Craig S. Johnson Presentation Overview Introduction Aeration Air & Digester gas challenges Gas flow metering
Using meters to measure steam flow
Page 1 of 6 April 1998 Plant Engineering SELECTING NEW TECHNOLOGY: PROBLEM SOLVING Using meters to measure steam flow Jesse L. Yoder, Ph.D., Senior Analyst, Automation Research Corp., Dedham, MA Key Concepts
Grant Agreement No. 228296 SFERA. Solar Facilities for the European Research Area SEVENTH FRAMEWORK PROGRAMME. Capacities Specific Programme
Grant Agreement No. 228296 SFERA Solar Facilities for the European Research Area SEVENTH FRAMEWORK PROGRAMME Capacities Specific Programme Research Infrastructures Integrating Activity - Combination of
Michael Montgomery Marketing Product Manager Rosemount Inc. Russ Evans Manager of Engineering and Design Rosemount Inc.
ASGMT / Averaging Pitot Tube Flow Measurement Michael Montgomery Marketing Product Manager Rosemount Inc. Russ Evans Manager of Engineering and Design Rosemount Inc. Averaging Pitot Tube Meters Introduction
The Unique Accelabar Flow Meter
The Unique Accelabar Flow Meter The Accelabar is a new and unique flow meter that combines two differential pressure technologies to produce operating ranges never before attainable in a single flow meter.
measurement, but almost any pipe elbow can be calibrated Elbow meters are not as potentially accurate as venturi,
Lecture 14 Flow Measurement in Pipes I. Elbow Meters An elbow in a pipe can be used as a flow measuring device much in the same way as a venturi or orifice plate The head differential across the elbow
In semiconductor applications, the required mass flows
Model-Based Multi-GasMulti-Range Mass Flow Controllers With Single Gas Calibration and Tuning JOOST LÖTTERS A model has been developed that accurately predicts the behavior of the flow sensor combined
Energy and Flow Measurement for Hydronic Systems
Energy and Flow Measurement for Hydronic Systems Presented By: George Szyszko Applications Consultant MCR for ONICON Incorporated Why Measure Thermal Energy? To control something, you must first measure
Flow Measurement in Pipes and Ducts. Flow Measurement in Pipes and Ducts, Course #503. Presented by:
Flow Measurement in Pipes and Ducts, Course #503 Presented by: PDH Enterprises, LLC PO Box 942 Morrisville, NC 27560 www.pdhsite.com This course is about measurement of the flow rate of a fluid flowing
FLUID FLOW Introduction General Description
FLUID FLOW Introduction Fluid flow is an important part of many processes, including transporting materials from one point to another, mixing of materials, and chemical reactions. In this experiment, you
RITTER Multiple Sonic Nozzle Calibration System
RITTER Multiple Sonic Nozzle Calibration System »Wouldn t it be great to eliminate doubtful measurement results by using proven measurement technology? Providing the most precise results ensures and increases
4.What is the appropriate dimensionless parameter to use in comparing flow types? YOUR ANSWER: The Reynolds Number, Re.
CHAPTER 08 1. What is most likely to be the main driving force in pipe flow? A. Gravity B. A pressure gradient C. Vacuum 2.What is a general description of the flow rate in laminar flow? A. Small B. Large
Testing Protocol for Differential Pressure Measurement Devices API MPMS Chapter 22.2
Testing Protocol for Differential Pressure Measurement Devices API MPMS Chapter 22.2 Steve Baldwin Chevron Energy Technology Company Houston, Texas USA Casey Hodges CEESI Measurement Solutions. Nunn, Colorado
Thermal Dispersion Mass Flow
Thermatel Thermal Dispersion Mass Flow Measurement Handbook Table of Contents Introduction...1 What is Mass Flow Measurement?...1 Types of Flow Transmitters...4 Differential Pressure...4 Orifice...4 Venturi...6
Gas Custody Transfer Calibration
Gas Custody Transfer Calibration Using multi variable temperature / pressure calibrators for flowmeter calibration 2013 Introduction Gas custody transfer flow computers require special calibration to perform
ABB Flowmeters Review of industrial processing flowmeters
White paper ABB Flowmeters Review of industrial processing flowmeters Understanding flowmeters and their pros and cons By Ron DiGiacomo, ABB Measurement Products One of the most critical measurements in
Chapter 10. Flow Rate. Flow Rate. Flow Measurements. The velocity of the flow is described at any
Chapter 10 Flow Measurements Material from Theory and Design for Mechanical Measurements; Figliola, Third Edition Flow Rate Flow rate can be expressed in terms of volume flow rate (volume/time) or mass
Theory overview of flow measurement using differential pressure devices based on ISO-5167 standard.
Theory overview of flow measurement using differential pressure devices based on ISO-567 standard. rian FL40 flow computer description. Flow Cad software users manual. Technical note, Differential pressure
Advances in Thermal Dispersion Mass Flow Meter Accuracy
Advances in Thermal Dispersion Mass Flow Meter Accuracy By Dan McQueen President Fluid Components International (FCI) Advances in Thermal Dispersion Mass Flow Meter Accuracy By Dan McQueen President Fluid
Head Loss in Pipe Flow ME 123: Mechanical Engineering Laboratory II: Fluids
Head Loss in Pipe Flow ME 123: Mechanical Engineering Laboratory II: Fluids Dr. J. M. Meyers Dr. D. G. Fletcher Dr. Y. Dubief 1. Introduction Last lab you investigated flow loss in a pipe due to the roughness
INDIAN STANDARDS FOR NATURAL GAS PIPELINE SYSTEM
INDIAN STANDARDS FOR NATURAL GAS PIPELINE SYSTEM 1. IS 15663(Part 1):2006 This code covers requirements and recommendations for the design, materials, construction and testing of pipelines made of steel
Flow Measurement Options for Pipeline and Open Channel Flow
Flow Measurement Options for Pipeline and Open Channel Flow October 2013 Presented by Molly Skorpik - 2013 Montana Association of Dam and Canal Systems Conference Irrigation Training and Research Center
V-CONE METERING PROGRAM User Manual
Flow Computer Division V-CONE METERING PROGRAM User Manual Form A6104 March 2002 Revision Tracking Sheet March 2002 This manual may be revised from time to time to incorporate new or updated information.
FLOW COMPUTERS METERING, MONITORING, & DATA ACQUISITIONS. Sami Halilah Dynamic Flow Computers Houston, Texas
FLOW COMPUTERS METERING, MONITORING, & DATA ACQUISITIONS Sami Halilah Dynamic Flow Computers Houston, Texas GENERAL LAYOUT This paper presents information about applications of flow computers in the oil
Gas Flow Measurement Software A Report for
Gas Flow Measurement Software A Report for National Measurement System Directorate Department of Trade & Industry 151 Buckingham Palace Road London, SW1W 9SS Report No: 332/99 Date: September 1999 The
The Versatile Differential Pressure Transmitter. By David Gunn Honeywell Process Solutions
The Versatile Differential Pressure Transmitter By David Gunn Honeywell Process Solutions The Versatile Differential Pressure Transmitter 2 Table of Contents Abstract... 3 Pressure Fundamentals... 3 Applications...
Energy Systems Engineering Technology
College of Technology Instrumentation and Control Module # 4 Flow Measurement Document Intent: The intent of this document is to provide an example of how a subject matter expert might teach Flow Measurement.
THEORETICAL UNCERTAINTY OF ORIFICE FLOW MEASUREMENT page 1 THEORETICAL UNCERTAINTY OF ORIFICE FLOW MEASUREMENT INTRODUCTION COEFFICIENT OF DISCHARGE
THEORETICAL UNCERTAINTY OF ORIFICE FLOW MEASUREMENT page 1 DANIEL MEASUREMENT AND CONTROL WHITE PAPERS THEORETICAL UNCERTAINTY OF ORIFICE FLOW MEASUREMENT www.daniel.com INTRODUCTION Orifice meters are
A basic introduction to steam
A basic introduction to steam FOR HOT, COLD, MOIST AND DRY, FOUR CHAMPIONS FIERCE. STRIVE HERE FOR MASTERY Milton 1666 Steam Wonderful Steam Very high heat content Recyclable Clean, non toxic Biodegradable
THE USE OF A CORIOLIS FLOW METER FOR MEASURING MOLASSES PRODUCTION IN A SUGAR MILL. ABSTRACT
THE USE OF A CORIOLIS FLOW METER FOR MEASURING MOLASSES PRODUCTION IN A SUGAR MILL. P. W. Rein 1, D. J. Muzzell 2, and N. Dolan 2 1 Audubon Sugar Institute, LSU AgCenter, St. Gabriel, LA, 2 Raceland Raw
For Multi-Parameter Meters see mvx
BULLETIN BULLETIN EM20607 VORTEX IN-LINE FLOW METERS Design Features For Multi-Parameter Meters see m Principles of Operation n No moving parts to wear or fail. n Electronics can be remotely mounted up
Laminar Flow Elements
Laminar Flow Elements Meriam Laminar Flow Elements (LFEs) are excellent for measuring low gas flow rates from 0.2 SCCM up to 2250 SCFM. They are inherently accurate and repeatable and are calibrated traceable
TANKJKT. Heat Transfer Calculations for Jacketed Tanks SCREEN SHOTS. Copyright 2015. By chemengsoftware.com
TANKJKT Heat Transfer Calculations for Jacketed Tanks SCREEN SHOTS Copyright 2015 By chemengsoftware.com Visit http://www.pipesizingsoftware.com/ for further information and ordering The following page
Flow Measurement. Reference - Flow Measurement FUNDAMENTALS. ρ = fluid density (lb/ft3 or kg/m3)
Flow Measurement FUDAMETALS Flowmetering terms can often seem cryptic Here are definitions of some of the most commonly used ACCURACY Accuracy is a quantity defining the limit that errs will not exceed
Flow Sensors. - mass flow rate - volume flow rate - velocity. - stream line parabolic velocity profile - turbulent vortices. Methods of measurement
Flow Sensors Flow - mass flow rate - volume flow rate - velocity Types of flow - stream line parabolic velocity profile - turbulent vortices Methods of measurement - direct: positive displacement (batch
Correcting a Coriolis Meter for Two Phase Oil & Gas Flow
Correcting a Coriolis Meter for Two Phase Oil & Gas Flow Chris Mills, NEL 1 INTRODUCTION In the oil & gas industry, the requirement for flow measurement of two phase oil and gas flow is prevalent. This
ME 538: Experiment # 1 Flow measurement and particle generation instruments
ME 538: Experiment # 1 Flow measurement and particle generation instruments Suresh Dhaniyala Mechanical and Aeronautical Engineering Clarkson University Flow rate measurement Various types of flowmeters
Heat Transfer Prof. Dr. Ale Kumar Ghosal Department of Chemical Engineering Indian Institute of Technology, Guwahati
Heat Transfer Prof. Dr. Ale Kumar Ghosal Department of Chemical Engineering Indian Institute of Technology, Guwahati Module No. # 04 Convective Heat Transfer Lecture No. # 03 Heat Transfer Correlation
T U R B I N E G A S M E T E R
TURBINE GAS METER TURBINE GAS METER CGT 1 2 3 4 5 6 7 Design and function page 2 General technical data page 3 Measurement outputs page 4 Dimensions and weights page 5 Performance page 7 Pressure loss
Chapter 3.5: Fans and Blowers
Part I: Objective type questions and answers Chapter 3.5: Fans and Blowers 1. The parameter used by ASME to define fans, blowers and compressors is a) Fan ration b) Specific ratio c) Blade ratio d) Twist
Rosemount Orifice Plate in Wet Gas
00870-0100-4810 January 2006 Page 1 Rosemount Orifice Plate in Wet Gas This paper discusses the phenomenon of wet gas measurement, definitions, and the need to accurately measure this mixture. This paper
HEAVY OIL FLOW MEASUREMENT CHALLENGES
HEAVY OIL FLOW MEASUREMENT CHALLENGES 1 INTRODUCTION The vast majority of the world s remaining oil reserves are categorised as heavy / unconventional oils (high viscosity). Due to diminishing conventional
Experiment # 3: Pipe Flow
ME 05 Mechanical Engineering Lab Page ME 05 Mechanical Engineering Laboratory Spring Quarter 00 Experiment # 3: Pipe Flow Objectives: a) Calibrate a pressure transducer and two different flowmeters (paddlewheel
F ox W hi t e Paper. Reduce Energy Costs and Enhance Emissions Monitoring Systems
F ox W hi t e Paper Reduce Energy Costs and Enhance Emissions Monitoring Systems A Technical White Paper from Fox Thermal Instruments Rich Cada, VP Sales & Marketing, Fox Thermal Instruments, Inc. 399
DEVELOPMENT OF HIGH SPEED RESPONSE LAMINAR FLOW METER FOR AIR CONDITIONING
DEVELOPMENT OF HIGH SPEED RESPONSE LAMINAR FLOW METER FOR AIR CONDITIONING Toshiharu Kagawa 1, Yukako Saisu 2, Riki Nishimura 3 and Chongho Youn 4 ABSTRACT In this paper, we developed a new laminar flow
OPTIMASS 1400 Technical Datasheet
OPTIMASS 1400 Technical Datasheet Sensor for mass flow First choice for universal applications Best price-performance ratio A wide range of options available with no restrictions The documentation is only
Experiment 3 Pipe Friction
EML 316L Experiment 3 Pipe Friction Laboratory Manual Mechanical and Materials Engineering Department College of Engineering FLORIDA INTERNATIONAL UNIVERSITY Nomenclature Symbol Description Unit A cross-sectional
Pipe Flow-Friction Factor Calculations with Excel
Pipe Flow-Friction Factor Calculations with Excel Course No: C03-022 Credit: 3 PDH Harlan H. Bengtson, PhD, P.E. Continuing Education and Development, Inc. 9 Greyridge Farm Court Stony Point, NY 10980
Entrained Gas Diagnostic with Intelligent Differential Pressure Transmitter
January Page Entrained Gas Diagnostic with Intelligent Differential Pressure Transmitter Dave Wehrs - Director, Pressure Engineering Andrew Klosinski - Application Engineer, Pressure Diagnostics Emerson
VAD. Variable Area Desuperheaters
Desuperheater overview Steam used in process plants can be superheated, that is, heated to a temperature above saturation. The excess of temperature above its saturation is called 'superheat'. Desuperheated
www.klmtechgroup.com TABLE OF CONTENT
Page : 1 of 24 Project Engineering Standard www.klmtechgroup.com KLM Technology #03-12 Block Aronia, Jalan Sri Perkasa 2 Taman Tampoi Utama 81200 Johor Bahru Malaysia S TABLE OF CONTENT SCOPE 2 DEFINITIONS
OPTIMASS 6000 Technical Datasheet
OPTIMASS 6000 Technical Datasheet Sensor for mass flow The high performance meter for process industries Cryogenic, high temperature and high pressure options Supreme liquid and gas performance with CT
APPLICATION OF DENSITOMETERS TO LIQUID MEASUREMENT Class # 2010
APPLICATION OF DENSITOMETERS TO LIQUID MEASUREMENT Class # 2010 Colin B. Blakemore Sr. Product Specialist Pipeline & Gas Measurement Products AMETEK Process Instruments 455 Corporate Boulevard Newark,
FLUID MECHANICS. TUTORIAL No.7 FLUID FORCES. When you have completed this tutorial you should be able to. Solve forces due to pressure difference.
FLUID MECHANICS TUTORIAL No.7 FLUID FORCES When you have completed this tutorial you should be able to Solve forces due to pressure difference. Solve problems due to momentum changes. Solve problems involving
COMBIMASS. Technical Data COMBIMASS eco-bio +
COMBIMASS Technical Data THE SYSTEM COMBIMASS The field transmitters of the COMBIMASS eco series are suitable for gas flow measurement and cover a wide range of different applications. The instruments
Take total control of your HVAC system with cost-saving flow and thermal energy meters
Take total control of your HVAC system with cost-saving flow and thermal energy meters Because you can t manage what you don t measure usa.siemens.com/pi Answers for Industry. Contents Introduction 03
THEORY AND APPLICATION OF KURZ THERMAL CONVECTION MASS FLOW METERS INSTRUMENTS
THEORY AND APPLICATION OF KURZ THERMAL CONVECTION MASS FLOW METERS INTRODUCTION Many versions of thermal convection mass flow meters have been made, starting in the early 1900 s. Originally labeled, hot
Design and Analysis of Various Bluff Objects for Vortex flow meters
Design and Analysis of Various Bluff Objects for Vortex flow meters T. Milinda Purna 1, L. Aarya 2, K. Lakshmi Nageswari 3 1 Assistant Professor, Department Of Electronics & Instrumentation, Sree Vidyanikethan
19th International North Sea Flow Measurement Workshop 22-25 October 2001 Kristiansand, Norway
19th International North Sea Flow Measurement Workshop 22-25 October 2001 Kristiansand, Norway OPTIMISATION OF FLOW MEASUREMENTS IN A PULSATING FLOW -EXPERIENCES FROM FIELD MEASUREMENTS- E. van Bokhorst
MODEL TEG-F20. Specification Sheet. TEG-F20 Specification Sheet Ver. 2011-0310. Copyright(C) 2011 Tsukasa Sokken Co., Ltd.
Direct EGR Flow Meter MODEL TEG-F20 Specification Sheet TEG-F20 Specification Sheet Ver. 2011-0310 Copyright(C) 2011 Tsukasa Sokken Co., Ltd. 1. Overview Sokken model TEG series is an EGR Flow meter to
Daniel Venturi Tubes and Flow Nozzles Brochure
Daniel Venturi Tubes and Flow Nozzles Brochure Is unaccounted hydrocarbon draining your bottom line? When the stakes are high, any amount of unaccounted hydrocarbon drains the bottom line. That's why companies
Industry faces unrelenting pressure to increase production
Reprinted with permission from CEP (Chemical Engineering Progress), March 2013. Copyright 2013 American Institute of Chemical Engineers (AIChE). Back to Basics Coriolis: The Direct Approach to Mass Flow
Laminar and Turbulent flow. Flow Sensors. Reynolds Number. Thermal flow Sensor. Flow and Flow rate. R = Mass Flow controllers
Flow and Flow rate. Laminar and Turbulent flow Laminar flow: smooth, orderly and regular Mechanical sensors have inertia, which can integrate out small variations due to turbulence Turbulent flow: chaotic
AKRON EDUCTORS TROUBLESHOOTING GUIDE OPERATION & THEORY OF EDUCTORS GENERAL OPERATING AND MAINTENANCE INSTRUCTIONS
AKRON EDUCTORS TROUBLESHOOTING GUIDE OPERATION & THEORY OF EDUCTORS GENERAL OPERATING AND MAINTENANCE INSTRUCTIONS Products Include: 60 gpm eductors Style 3060, 3061, 3062 & 3070 95 gpm eductors Style
Application of the Orifice Meter for Accurate Gas Flow Measurement page 1. Application of the Orifice Meter for Accurate Gas Flow Measurement.
Application of the Orifice Meter for Accurate Gas Flow Measurement page 1 DANIEL MEASUREMENT AND CONTROL WHITE PAPER Application of the Orifice Meter for Accurate Gas Flow Measurement www.daniel.com Summary
Minor losses include head losses through/past hydrants, couplers, valves,
Lecture 10 Minor Losses & Pressure Requirements I. Minor Losses Minor (or fitting, or local ) hydraulic losses along pipes can often be estimated as a function of the velocity head of the water within
Flow Sensors. Convenient, Reliable and Economical Flow Measurement. THORNTON Leading Pure Water Analytics
THORTO Leading Pure Water nalytics Economical Paddlewheel Hi-Purity PF Ultrasonic Vortex Insertion-type Vortex Convenient, Reliable and Economical Flow Measurement Paddlewheel Reliable and Economical Inline
Experimental Evaluation of the Discharge Coefficient of a Centre-Pivot Roof Window
Experimental Evaluation of the Discharge Coefficient of a Centre-Pivot Roof Window Ahsan Iqbal #1, Alireza Afshari #2, Per Heiselberg *3, Anders Høj **4 # Energy and Environment, Danish Building Research
191: Calibration and Standards in Flow Measurement. Richard Paton National Engineering Laboratory, Scotland, UK 1 GENERAL PRINCIPLES
191: Calibration and Standards in Measurement Richard Paton National Engineering Laboratory, Scotland, UK 1 General Principles 1 2 Gravimetric Calibration of Liquid meters 2 3 Volumetric Calibration of
Fluid Flow Instrumentation
Fluid Flow Instrumentation In the physical world, mechanical engineers are frequently required to monitor or control the flow of various fluids through pipes, ducts and assorted vessels. This fluid can
A LAMINAR FLOW ELEMENT WITH A LINEAR PRESSURE DROP VERSUS VOLUMETRIC FLOW. 1998 ASME Fluids Engineering Division Summer Meeting
TELEDYNE HASTINGS TECHNICAL PAPERS INSTRUMENTS A LAMINAR FLOW ELEMENT WITH A LINEAR PRESSURE DROP VERSUS VOLUMETRIC FLOW Proceedings of FEDSM 98: June -5, 998, Washington, DC FEDSM98 49 ABSTRACT The pressure
Thermal Mass Flow Meter (Series MST)
Overview MaxiFlo TM MST series Thermal Mass Flow Meter is the instrument of choice for reliable and accurate measurement of mass flows for various gases. It measures the mass flow of gas based on constant
INTRODUCTION SOME USES OF SPRAY NOZZLES INTRODUCTION TYPES OF SPRAY NOZZLES
SOME USES OF SPRAY NOZZLES It is important that the nozzle you select is appropriate for your particular application Liquid sprays are used in a seemingly endless variety of applications Some of the more
Chapter 8: Flow in Pipes
Objectives 1. Have a deeper understanding of laminar and turbulent flow in pipes and the analysis of fully developed flow 2. Calculate the major and minor losses associated with pipe flow in piping networks
Measurement & Analytics. VIS Multiphase Flow Meter High gas content applications solved with no radioactive source - Measurement made easy
Measurement & Analytics VIS Multiphase Flow Meter High gas content applications solved with no radioactive source - Measurement made easy ABB s VIS Multiphase Flow Meter Easy to operate, accurate and fieldproven
Gas Well Deliverability Testing
Gas Well Deliverability Testing What is deliverability testing? The "deliverability" of a gas well can be defined as the well's capacity to produce against the restrictions of the well bore and the system
Implementing New Technology at TransCanada Meter Stations -- Better, Faster, Cheaper
2001 Canadian Gas Association Gas Measurement School Winnipeg, Manitoba Implementing New Technology at TransCanada Meter Stations -- Better, Faster, Cheaper Prepared by: Dean Mah, P.Eng. Warren Peterson
Theory, Application, and Sizing of Air Valves
Theory, Application, and Sizing of Air Valves VAL-MATIC VALVE AND MANUFACTURING CORP. 905 RIVERSIDE DRIVE, ELMHURST, IL 60126 TEL. (630) 941-7600 FAX. (630) 941-8042 www.valmatic.com 1 THEORY, APPLICATION,
CFD Analysis Of Multi-Phase Flow And Its Measurements
IOSR Journal of Mechanical and Civil Engineering (IOSR-JMCE) e-issn: 2278-1684,p-ISSN: 2320-334X, Volume 9, Issue 4 (Nov. - Dec. 2013), PP 30-37 CFD Analysis Of Multi-Phase Flow And Its Measurements C
MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter
Thermal Mass meter and Temperature Transmitter Description The MTI10 insertion thermal mass flowmeter and the MTL10 in-line thermal mass flowmeter provide accurate mass flow measurement of clean, dry gases
Principals of Condensing Boiler System Design
Principals of Condensing Boiler System Design Dennis Jones, P.E. Member ASHRAE ABSTRACT Condensing boilers can provide significant energy savings due to operating efficiencies as high as 98% as compared
UPM 15010. Figure 1 MPFM installed on well pad
UPM 151 In-line Multiphase Flowmeter Field Trial Comparison vs. Three Phase Flow Separator on Naturally Flowing Shale Wells A. Michael Jones, Independent Flow Measurement Consultant, Travis Gaskill, Daniel
Model 43AP Pneumatic Controller, Style B
Instruction MI 011-476 January 1980 Model 43AP Pneumatic Controller, Style B Installation and Operation Model 43AP Controller continuously detects the difference between a process measurement and its set
FLOW METER SPECIFICATION AND APPLICATION ANALYSIS Class #41
FLOW METER SPECIFICATION AND APPLICATION ANALYSIS Class #41 Curtis Gulaga Business Development Manager CB Engineering Ltd. #20, 5920 11 th Street SE Calgary, AB T2H 2M4 1.0 Introduction Today s working
Technical & Sizing Bulletin for Meriam LFEs. Laminar Flow Elements
Technical & Sizing Bulletin for Meriam LFEs Laminar Flow Elements What they are... Meriam Laminar Flow Elements are gas volume rate of flow differential producers operating on capillary flow principles.
Air Flow Measurements
ME-EM 30 ENERGY LABORATORY Air Flow Measurements Pitot Static Tube A slender tube aligned with the flow can measure local velocity by means of pressure differences. It has sidewall holes to measure the
VAD Variable Area Desuperheaters
Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without
Physics 1114: Unit 6 Homework: Answers
Physics 1114: Unit 6 Homework: Answers Problem set 1 1. A rod 4.2 m long and 0.50 cm 2 in cross-sectional area is stretched 0.20 cm under a tension of 12,000 N. a) The stress is the Force (1.2 10 4 N)
SIZING AND CAPACITIES OF GAS PIPING
APPENDIX A (IFGS) SIZING AND CAPACITIES OF GAS PIPING (This appendix is informative and is not part of the code.) A.1 General. To determine the size of piping used in a gas piping system, the following
Redefining Spray Technology
Redefining Spray Technology Macrospray Single-Point Nozzles Macrospray Spider Nozzles Macrospray nozzle technology Improved performance, lower cost Macrospray nozzle technology from Parker Hannifin s Gas
inter.noise 2000 The 29th International Congress and Exhibition on Noise Control Engineering 27-30 August 2000, Nice, FRANCE
Copyright SFA - InterNoise 2000 1 inter.noise 2000 The 29th International Congress and Exhibition on Noise Control Engineering 27-30 August 2000, Nice, FRANCE I-INCE Classification: 2.1 WHISTLING PHENOMENA
Overview of the state of the art heat measurement technologies for larger solar thermal systems
Overview of the state of the art heat measurement technologies for larger solar thermal systems Overview of the state of the art heat measurement technologies for larger solar thermal systems... 1 Introduction...
C. starting positive displacement pumps with the discharge valve closed.
KNOWLEDGE: K1.04 [3.4/3.6] P78 The possibility of water hammer in a liquid system is minimized by... A. maintaining temperature above the saturation temperature. B. starting centrifugal pumps with the
Smart Electromagnetic Flowmeter Open channel Flowmeter Detector
Magne3000 PLUS Smart Electromagnetic Flowmeter Open channel Flowmeter Detector Model NNK150/951 OVERVIE The Magne3000 PLUS Electromagnetic Flowmeter is submersible type of flowmeter mainly used for flow