1 Power Supply Unit PS 1000/ VAC / 24 VDC Continuous Current 40 A PS 1000/ VDC Electronically controlled power supply unit Table of Contents Page 1 Power Supply Unit PS 1000/ Mounting the PS 1000/ and Mounting the PS 1000/ and 011 in the M 3421 Subrack ESD Protective Measures Mounting the Power Supply Unit Removing the Power Supply Unit Product Description Standards Block Diagram Function of the Fault Relay Operation Operating Multiple Power Supply Units in the M 3421 Subrack Mechanical Coding Adjustment of Power Supply Units Connected in Parallel Technical Data PS 1000/ Maintenance of 12

2 1 Power Supply Unit PS 1000/ The electronic power supply unit is designed for the power supply of safety-related HIMA controllers. Different variants of the power supply units exist: Variant Mounting Form Mounting PS 1000/ Cartridge M " subrack PS 1000/ coated Cartridge M " subrack PS 1000/ Wall mounting Backplane PS 1000/ coated Wall mounting Backplane Table 1: Power Supply Unit Variants 1.1 Mounting the PS 1000/ and 017 The scope of delivery of the variants PS 1000/ and 017 includes: Designation Power supply unit with wall bracket Description Wall bracket with four fastening points High-current female connector (XG.1) Power supply output L-, L+, R+ Female connector (XG.2) Female connector (XG.3) Lettering and marking kit Fault relay contact NO, C, NC Power supply input L, N, PE Label for female connectors and power supply unit Table 2: Scope of Delivery of the Variants PS 1000/ and 017 Observe the following points when mounting the PS 1000/ and 017: Maintain a distance of 30 mm in front of the fan grill to ensure sufficient aeration. When wiring, observe the minimum cross sections specified in Chapter 1.8. The power supply unit is equipped with four fastening points and can be secured vertically or horizontally. The fastening points are spaced in 25 mm intervals such that the power supply unit fits the mounting frame's profile rails within the control cabinet, see the scale drawing in Figure 2. If the four power supply units are mounted vertically on the profile rail, they can be located adjacent to one another in an 800 mm wide control cabinet, see Figure 3. To secure the power supply unit to the profile rail, use the HIMA fastening parts kit M 2212 (part no ) consisting of cage nuts, Phillips head bolts (M6 x 16) and washers. For the 4.5 mm drilled holes, use B 5.5 x 13 tapping screws in accordance with DIN To secure the power supply unit to a mounting plate, use M6 screws and washers. 2 of 12

3 Tools, components and utilities Screwdriver, 1.0 x 5.5 blade for high-current female connector (XG.1) Screwdriver, 0.6 x 3.5 blade for female connector (XG.2, XG.3) 1. Prior to mounting the power supply unit, stick the corresponding labels of the lettering and marking kit to the female connectors and power supply, see Figure Secure the power supply units to the profile rail or backplane (e.g., mounting plate). For the profile rail, use the fastening parts kit M 2212 or the tapping screws. 3. Wire the female connectors using the corresponding screwdriver. 4. Plug the wired female connectors into the power supply unit and use the corresponding screwdriver to secure them, see Figure Ensure that strain is relieved from the connected cables. 6. The power supply units must have a conductive connection to the earth of the mounting frame or backplane. XG.2 Fail XG.1 24VDC NO C NC L- L+ R+ XG.3 230VAC L N PE Figure 1: Location of Labels and Female Connectors 3 of 12

4 71,90 25,00 125,00 25,00 96,70 175,00 Type Label Figure 2: Scale Drawing of the Variants PS 1000/ and 017 for Wall Mounting Figure 3: Four Power Supply Units Vertically Secured in the 800 mm wide Control Cabinet 4 of 12

5 1.2 Mounting the PS 1000/ and 011 in the M 3421 Subrack The equipment depends on the wiring of the M 3421 subrack. Slots not in use can be fitted with the M 4413 dummy front plate (part no ). Maintain a distance of 30 mm to the front of the power supply fan ESD Protective Measures Only personnel with knowledge of ESD protective measures may install and remove a power supply unit. An electrostatic discharge can damage the electronic components within the systems. Touch a grounded object to discharge any static in your body. When performing the work, make sure that the workspace is free of static, and wear an ESD wrist strap. If not used, ensure that the module is protected from electrostatic discharge, e.g., by storing it in its packaging Mounting the Power Supply Unit A Phillips screwdriver PH1 is required for mounting the power supply unit. 1. Check the mechanical coding on the subrack. 2. In the off-state, insert the power supply unit completely in the subrack. 3. Use the four captive screws to secure the power supply unit to the subrack housing. 4. The M 4413 dummy plates can be secured to the slots not in use. Please check the correct coding on the subrack before inserting the power supply unit. Inserting a 48-V instead of a 24-V power supply unit causes the destruction of electronic components Removing the Power Supply Unit A Phillips screwdriver PH1 is required for removing the power supply unit. 1. Use the overcurrent circuit breaker to switch off the power supply unit. 2. Release the four captive screws on the subrack. 3. Remove the power supply unit from the subrack. 5 of 12

6 1.3 Product Description Figure 4: PS 1000/ VDC Front View and Rear View Figure 5: PS 1000/ VDC Side View The PS 1000/ and 011 variants are modular cartridges for use in the 19'' subrack M 3421, with 4 RU high, see M 3421 data sheet. The M 3421 subrack is designed for up to three power supply units and is used for the HIMA PS 1000 series of power supply units. This variant is mechanically coded to ensure that only the correct power supply unit type can be inserted into the subrack, see Chapter The PS 1000/ and 017 variants are secured to a backplane (e.g., mounting plate), see Chapter 1.1. The power supply unit supplies a 24 VDC output voltage to the L+/L- or R+/L- terminals with a nominal current of 40 A (short-circuit-proof) and bridges voltage drop outs of 20 ms. For redundant operation, the power supply units can be connected in parallel via the decoupled R+ terminals, see Chapter of 12

7 The power supply unit is equipped with a fan on the front side. If the fan fails, the fault relay trips, see Chapter 1.5. The fault relay's contact is lead through to the rear side of the power supply unit. Two LEDs on the front plate indicate that the power supply is operating properly. The green LED RUN is lit if sufficient output voltage is available. The red LED ERR is lit if fan speed is too low, the fan is idle or if the output voltage is too low. A ΔU potentiometer is located on the front side for adjusting the voltage, see Chapter Standards The power supply unit's output voltage meets the requirements for SELV- and/or PELV circuits. PS 1000/ CE IEC : 2007 IEC : 2005 IEC : 2007 IEC : 2005 EMC Directive EX Directive Low Voltage Directive BUREAU VERITAS Table 3: Standards 2004/108/EC ATEX 94/9/EC, for variants PS1000/ and /95/EC Rules for the Classification of Steel Ships 1.4 Block Diagram Figure 6: Block Diagram 7 of 12

8 1.5 Function of the Fault Relay The fault relay's contact can be used to connect optical and acoustic detectors with a current input of up to 1 A, see Chapter 1.8. The fault relay is activated during normal operation and trips if the following faults occur: The fan speed is too low. The fan is blocked. The output voltage is too low. The temperature is too high. The power supply unit is defective. The following table describes the statuses of the fault relay contacts: Contact (Fail) C-NC closed (C-NO open) C-NC open (C-NO closed) State Relay energized, normal function Relay de-energized, fault within the power supply unit Table 4: Fault Relay States 8 of 12

9 1.6 Operation The power supply unit must be switched on and off using the thermal overcurrent circuit breaker located on the front side. To switch on, press the overcurrent circuit breaker until it is engaged. To ensure the soft start electronics can regulate the power-on current, wait at least 1 minute after switching the power supply unit off and before switching it on again. All connections are established using separated female connectors located on the back of the power supply unit. The decoupled R+ terminal must be used when multiple power supply units are connected in parallel to increase power or implement redundancy Operating Multiple Power Supply Units in the M 3421 Subrack All connections for the power supply units are established using separated female connectors located on the back of the subrack, see Figure 8. With redundant power supply units, a unit can be replaced during operation. Prior to removing the power supply unit, it must be switched off using the overcurrent circuit breaker located on the front side. ERR ERR ERR DU DU RUN DU RUN F F F Figure 7: Front View of a Fully Equipped M 3421 Subrack XG.8 Fail XG.7 24VDC XG.5 Fail XG.4 24VDC XG.2 Fail XG.1 24VDC NO C NC L- L+ R+ NO C NC NO C NC L- L+ R+ L- L+ R+ XG.9 230VAC L N PE XG.6 230VAC L N PE XG.3 230VAC L N PE Figure 8: M 3421 Subrack's Rear View with Terminals 9 of 12

10 1.6.2 Mechanical Coding The variants for the M " subrack are mechanically coded on the rear side. The coding is performed with up to 4 coding pins and the corresponding coding screws are screwed in to the rear side of the M 3421 subrack. The Variants PS 1000/ and 011 are not coded. To prevent the use of coded power supply units, screw all coding screws delivered with the PS 1000/ and 011 in to the M 3421 subrack, see Figure 9. Figure 9: Securing the Coding Screws on the M 3421 Subrack 1.7 Adjustment of Power Supply Units Connected in Parallel The output voltage for the power supply units is preset in the factory to 24.2 V ± 10 mv with 40 A load on L+. Decoupling reduces the output voltage on R+ by the amount of voltage drop, see Chapter 1.8. To avoid load differences during parallel operation, connect cables of the same length to R+. The power supply units are adjusted to other voltage ranges using the ΔU potentiometer located on the front side. 1. Measure the output voltage on each power supply unit's R+. 2. Turn the ΔU potentiometer to the desired output voltage (approx VDC) 3. Repeat step 2 with all power supply units connected in parallel. 4. Use a clamp-on ammeter to verify that the current of all power supply units connected in parallel is distributed uniformly. 5. If the current is not distributed uniformly, use the ΔU potentiometer to adjust the output voltage. 10 of 12

11 1.8 Technical Data PS 1000/ Power Supply Unit Input voltage Output voltage L+ Output voltage R+ Thermal overcurrent circuit breaker Load Crest factor at 20 A output current Max. switch-on current 230 VAC, % and 240 VAC, %, Hz 24 VDC, short-circuit-proof 10 % adjustable using a ΔU potentiometer (L+) VDC at 40 A 250 VAC, 10 A 40 A continuous load 2.15 (I RMS = 3.25 A, I peak = 7.0 A) 7 A Power factor 0.71 Regulation < 100 mv with load change of % Efficiency > 89 % Power dissipation Interruption time Type of protection Humidity < 110 W 20 ms IP20 Ambient temperature C Storage temperature C Dimensions of the cartridge for wall mounting Weight External fusing Connectors L, N, PE (XG.3) L+, R+, L- (XG.1) NC, C, NO (XG.2) Fault contact (Fail) Switching current MTTF Table 5: Product Data < 95 % relative humidity, non-condensing 28 HP, 4 RU W x H x D: 142 x 173 x 281 mm W x H x D: x x mm approx. 6 kg 16 A Minimum cross section for wiring: 240 VAC 1.5 mm 2 24 VDC 10 mm 2 Fail 0.5 mm 2 One potential-free change-over contact, connection via terminals 3 x 1.5 mm 2 located in the subrack 30 VDC / 1 A 30 VAC / 0.5 A 30 years 11 of 12

12 1.9 Maintenance HIMA strongly recommends replacing the power supply unit fan in accordance with the specified maintenance interval. HIMA cannot be held liable for damages caused by improper maintenance. Operating temperature 40 C Maintenance Interval Every 5 years > 40 C Every 3 years Table 6: Maintenance Interval The fan may only be replaced by HIMA. Additional maintenance actions are not required. 12 of 12

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1 Power Supply Unit, Primary Switched, Narrow Design MINI POWER provides: Extra narrow design with widths of 22.5 mm, 45 mm, and 67.5 mm (0.886, 1.772, and 2.657 in.) Global use due to a wide-range input

More information

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information. Product and Applications Description The power supply units N 125/x2 can supply DC 24 V power from an additional pair of terminals (yellowwhite). This DC 24 V output voltage can be used to power e.g. an

More information

IMR 6000/10../20../30

IMR 6000/10../20../30 IMR 6000/10../20../30 System frame Component of the MMS 6000 Machine Monitoring System Applications: Slots for adaptation of the signal processing periphery (monitors, logic cards and interface cards)

More information

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: 2868567. DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: 2868567. DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase Extract from the online catalog STEP-PS/1AC/12DC/1.5 Order No.: 2868567 DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase Commercial data EAN 4046356292924 Pack 1 pcs. Customs tariff

More information

5-Slot Housing and FrameSaver 9000 Series Access Carrier AC Power Supply Installation Instructions

5-Slot Housing and FrameSaver 9000 Series Access Carrier AC Power Supply Installation Instructions TM 5-Slot Housing and FrameSaver 9000 Series Access Carrier AC Power Supply Installation Instructions Document Number 9000-A2-GN17-30 August 1998 Before You Begin Both the 5-slot housing and the FrameSaver

More information

Power Supply and Indicator Unit Type 5024-1. Fig. 1 Type 5024-1. Mounting and Operating Instructions EB 9539 EN

Power Supply and Indicator Unit Type 5024-1. Fig. 1 Type 5024-1. Mounting and Operating Instructions EB 9539 EN Power Supply and Indicator Unit Type 5024-1 Fig. 1 Type 5024-1 Mounting and Operating Instructions EB 9539 EN Edition October 2003 Application 1 Application The Type 5024-1 Power Supply and Indicator Unit

More information

MCR1900 Media Converter 19-Slot Chassis

MCR1900 Media Converter 19-Slot Chassis MCR1900 Media Converter 19-Slot Chassis Installation Guide Part #5500304-11 Copyright Statement This document must not be reproduced in any way whatsoever, either printed or electronically, without the

More information

Redundancy Module QUINT-DIODE/40

Redundancy Module QUINT-DIODE/40 Redundancy Module QUT DIODE provides: 00% decoupling of power supplies connected in parallel Can be installed in potentially explosive areas Load currents up to 60 A supported Easy assembly by snapping

More information

Express5800/120Ed. Rack Mount Kit Installation Procedures PN: 455-01607-001

Express5800/120Ed. Rack Mount Kit Installation Procedures PN: 455-01607-001 Express5800/120Ed Rack Mount Kit Installation Procedures PN: 455-01607-001 Proprietary Notice and Liability Disclaimer The information disclosed in this document, including all designs and related materials,

More information

Chrome DIN Rail Power Supply 24V 30W 1 Phase (Class II & NEC Class 2) / DRC-24V30W1AZ

Chrome DIN Rail Power Supply 24V 30W 1 Phase (Class II & NEC Class 2) / DRC-24V30W1AZ Highlights & Features Protection Class II, Double Isolation (No Earth connection is required) Universal AC input voltage without power de-rating Efficiency > 87.0% @ 115Vac & 230Vac NEC Class 2 / Limited

More information

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous Safety relay for monitoring E-STOP pushbuttons. Approvals Unit features Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous 1 auxiliary contact (N/C), instantaneous Safe separation of

More information

Contractors Guide Central Inverter System Installation

Contractors Guide Central Inverter System Installation Contractors Guide Central Inverter System Installation Step By Step Procedures 2,200 Watt/VA 6 Step Installation 1. Mount Bottom Cabinet 2. Mount Top Cabinet 3. Install Batteries 4. Install Conduit 5.

More information

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw 4 937 DESIO Current valve for AC 24 V pulse/pause control of electrical loads up to 30 kw SEA45.1 Use The current valve is used for the control of electric heating elements in heating, ventilation and

More information

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points Features SELV Compliant No Detection Passive Injector Gigabit Compatible Full Protection

More information

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector Product datasheet Characteristics TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector Main Range of product Product or component type Range compatibility Enclosure material Bus

More information

Refer installation of power supplies to qualified service personnel.

Refer installation of power supplies to qualified service personnel. AC Power Supply For 5-Slot Housing and 9000 Series Access Carrier Installation Instructions Document Number 9000-A2-GN17-50 August 2000 Before You Begin Both the 5-slot housing and the 9000 Series Access

More information

XUSL4E4BB091NS2 XUSL type 4 - Slave2 - For body protection - 4 Beams, Hp = 910 mm

XUSL4E4BB091NS2 XUSL type 4 - Slave2 - For body protection - 4 Beams, Hp = 910 mm Characteristics XUSL type 4 - Slave2 - For body protection - 4 Beams, Hp = 910 mm Complementary Detection system Kit composition [EAA] effective aperture angle Emission Main Range of product Product or

More information

FIRERAY 2000 Installation Guide

FIRERAY 2000 Installation Guide FIRERAY 2000 Installation Guide Features Range 33ft to 330 ft. 24Vdc operation Selectable alarm thresholds Low current consumption Ground level electronics Manual or Automatic reset System Description

More information

PS6500 Storage Arrays Rack Mount Instructions

PS6500 Storage Arrays Rack Mount Instructions PS6500 Storage Arrays Rack Mount Instructions Part Number: R724M Rev. A01 Copyright 2010 Dell, Inc. All rights reserved. Dell is a trademark of Dell, Inc. EqualLogic is a registered trademark. All trademarks

More information

VIBRATION MONITORING OF FANS INSTALLED IN ROAD TUNNELS

VIBRATION MONITORING OF FANS INSTALLED IN ROAD TUNNELS VIBRATION MONITORING OF FANS INSTALLED IN ROAD TUNNELS CEMB SPA Via Risorgimento, 9 Mandello del Lario (Lc), Italy [email protected] www.cemb.com INSTRUMENT FOR MONITORING VIBRATIONS OF FANS INSTALLED IN ROAD

More information

Co-location Interconnect Power Panel (CIPP) Installation Guide

Co-location Interconnect Power Panel (CIPP) Installation Guide Co-location Interconnect Power Panel (CIPP) Installation Guide Document INS-97xxxxxxx This guide covers the following part numbers- Trimm 97xxxxxxx Series Table of Contents Section 1 - General Information...

More information

ACS-30-EU-EMDR-10-MOD

ACS-30-EU-EMDR-10-MOD Multi-application heat tracing Control and Monitoring in commercial and residential buildings Roof & Gutter de-icing sensor module Technical Information Approvals Module IP rating Ambient operating temperature

More information

SYSTEM DESCRIPTION Termination Boards

SYSTEM DESCRIPTION Termination Boards PROCESS AUTOMATION SYSTEM DESCRIPTION Termination Boards Non-IS Termination Boards for Yokogawa CENTUM C3 and ProSafe RS ISO9001 With regard to the supply of products, the current issue of the following

More information

Actuator-Sensor-Interface

Actuator-Sensor-Interface Selection and ordering data Design Order No. Price Pack 3RX9 307-0AA00 3RX9 307-1AA00 4FD5 213-0AA10-1A 3RX9 305-1AA00 3RX9 306-1AA00 Single output IP 65 current 2.4 A Rated input voltage DC 24 V current

More information

Edition Perfect combination 9 Power supplies Electronic P Edition kaging www clear order..biz information in the catalogue

Edition Perfect combination 9 Power supplies Electronic P Edition kaging www clear order..biz information in the catalogue 9 Power supplies Übersicht PROLINE Overview... 0 Power supplies Cabinets... 1 Wall mounted cases... 2 slimpower AC/DC switched-mode power supply 42 W, 3 HP Compact and low interference Accessories for

More information

Power Supply, Primary Switch Mode, Narrow Design MINI-PS-100-240AC/24DC/2

Power Supply, Primary Switch Mode, Narrow Design MINI-PS-100-240AC/24DC/2 Power Supply, Primary Switch Mode, Narrow Design -PS-100-240AC/24/2 POWER provides: Extra narrow widths of 22.5 and 45 mm (0.886 and 1.772 in.) Global use due to a wide range input A high level of operational

More information

EATS16 EATS16N. Installation and user manual ENGLISH. Copyright 2015 EATON All rights reserved.

EATS16 EATS16N. Installation and user manual ENGLISH. Copyright 2015 EATON All rights reserved. ENGLISH EATS6 EATS6N Installation and user manual Copyright 05 EATON All rights reserved. Service and suppt: Call your local service representative SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS. This manual

More information

Chrome DIN Rail Power Supply 24V 91.2W 1 Phase (Class II & NEC Class 2) / DRC-24V100W1AZ

Chrome DIN Rail Power Supply 24V 91.2W 1 Phase (Class II & NEC Class 2) / DRC-24V100W1AZ Highlights & Features Protection Class II, Double Isolation (No Earth connection is required) Universal AC input voltage without power de-rating Efficiency > 87.0% @ 115Vac, > 89.0% @ 230Vac NEC Class

More information

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2 Type code Ident no. 1545065 Number of channels 2 Dimensions (W x L x H) 108 x 145 x 77.5 mm CoDeSys-programmable acc. to IEC 61131-3 Cable max. 50 m between interface and read/write head 10/100 Mbps Male

More information

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q605 0054 R0001

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q605 0054 R0001 Analogue Input, -fold, MDRC, GH Q605 005 R0001 The analogue input is a DIN rail mounted device for insertion in the distribution board. It is connected to the EIB via the bus connecting terminal supplied.

More information

HERZ-Thermal Actuators

HERZ-Thermal Actuators HERZ-Thermal Actuators Data Sheet 7708-7990, Issue 1011 Dimensions in mm 1 7710 00 1 7710 01 1 7711 18 1 7710 80 1 7710 81 1 7711 80 1 7711 81 1 7990 00 1 7980 00 1 7708 11 1 7708 10 1 7708 23 1 7709 01

More information

5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual

5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual 5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual Content Overview... 1 Introduction... 1 Features... 3 Packing List... 4 Safety Precaution... 4 Hardware Description... 5 Front Panel...

More information

Clear Glass Sensor. Ordering Information E3S-CR67/62. Optimum Sensor for Detecting Transparent Glass and Plastic Bottles

Clear Glass Sensor. Ordering Information E3S-CR67/62. Optimum Sensor for Detecting Transparent Glass and Plastic Bottles Clear Glass Sensor Optimum Sensor for Detecting Transparent Glass and Plastic Bottles E3S-CR67/62 Retroreflective Sensor smoothly detects 5-mm gaps. Detects transparent bottles that have a lens effect.

More information

Product and functional description

Product and functional description Product and functional description The KNX / DALI gateway N 141/02 is a 4 MU wide, DINrail mounted KNX device with one DALI interface to which up to 64 DALI actuators (e.g. DALI ballasts) can be connected

More information

OVR-3SP Recloser with PCD Control Style Guide 1VAL263901-SG March 30, 2009 Revision B

OVR-3SP Recloser with PCD Control Style Guide 1VAL263901-SG March 30, 2009 Revision B OVR-3SP Recloser with PCD Control Style Guide 1VAL263901-SG March 30, 2009 Revision B The OVR-3SP three-phase recloser style guide aids in the proper selection of your OVR-3SP style number. The OVR-3SP

More information

Linear Luminaire with LED Series EXLUX 6402/2

Linear Luminaire with LED Series EXLUX 6402/2 > Latest LED technology with a high luminous efficacy and a long service life > As pendant light fitting or side entry lamp > Central locking > All-pole disconnection by means of an N/C switch when the

More information

Safety technique. Emergency stop module BO 5988 safemaster

Safety technique. Emergency stop module BO 5988 safemaster Safety technique Emergency stop module BO 5988 safemaster 0221562 Function diagram Pushbutton on Mains or emergencystop () K1 According to EC Directive for machines 98/37/EG According to IEC/E 60204-1

More information

CliQ DIN Rail Power Supply 24V 120W 1 Phase / DRP024V120W1AA

CliQ DIN Rail Power Supply 24V 120W 1 Phase / DRP024V120W1AA Highlights & Features Reliable design, with expected life of 10 years Compact, rugged design for ease of handling and installation Multiple connections to terminals allowed Designed for Class I Div. 2

More information

ABLOY DA60 SWING DOOR OPERATOR Installation and commissioning manual Abloy Oy An ASSA ABLOY Group company APPROVALS / STANDARDS Low Voltage directive 7//EEC as amended by the directive 9/68/EEC EMC directive

More information

I nstallation. M100Q Series Proportional Actuator with R81Q Controller Board for Thermistor Sensor Applications. Tools Needed.

I nstallation. M100Q Series Proportional Actuator with R81Q Controller Board for Thermistor Sensor Applications. Tools Needed. FANs 268.1, 1628.3 Installation Bulletin M100Q Issue Date 1099 M100Q Series Proportional Actuator with R81Q Controller Board for Thermistor Sensor Applications I nstallation Parts Included M110QGA-1 and

More information

Laserlyte-Flex Alignment System

Laserlyte-Flex Alignment System Laserlyte-Flex Alignment System LaserLyte-Flex The LaserLyte-Flex Alignment System is a unique, interchangeable, low cost plug and play laser system. Designed specifically for aligning and positioning

More information

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application 33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application Features Compliant with the IEEE802.3at Standard -40 to +60 C Temperature Range Diagnostic LEDs Full Protection

More information

MINI MCR-SL-R-UI(-SP)

MINI MCR-SL-R-UI(-SP) Resistance/potiposition transducer INTERFACE Data Sheet 0807_en_05 Description PHOENIX CONTACT - 0/008 Features The slim MINI MCR-SL-R-UI... potiposition transducer has a width of only 6. mm and converts

More information

HMI display Installation Guide

HMI display Installation Guide HMI display Installation Guide Product Description Specifications Important Information o Package Contents o Related Documents o Accessories Cautions and Warnings Mounting and Dimensions o BAC-DIS-ENC

More information

Modular I/O System Analog and Digital Interface Modules

Modular I/O System Analog and Digital Interface Modules OPERATING INSTRUCTIONS Modular I/O System Analog and Digital Interface Modules Installation Operation Maintenance Document Information Document ID Title: Operating Instructions Modular I/O System Part

More information

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features Central 48 V DC Power Supplies for PoE-Components MICROSENS Description Active network equipment which is supporting the Power-over-Ethernet functions, typically requires a powerful 48 V DC power supply.

More information

S-series Mass Connection Solutions

S-series Mass Connection Solutions DeltaV Distributed Control System Product Data Sheet March 2015 S-series Mass Connection Solutions Fast, easy and error-free cabinet wiring Modular design, improves reliability Lowers overall termination

More information

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description Photoelectrics, Background Suppression reflective with IR light Main features Description The PD30ET... stainless steel sensors are built with high-quality materials and designed for harsh environments.

More information

Power Supply, Primary Switch Mode, Narrow Design MINI-PS-100-240AC/2x15DC/1

Power Supply, Primary Switch Mode, Narrow Design MINI-PS-100-240AC/2x15DC/1 Power Supply, Primary Switch Mode, Narrow Design -PS-100-240AC/2x15DC/1 POWER provides: Extra narrow widths of 22.5 and 45 mm (0.886 and 1.772 in.) Global use due to a wide range input A high level of

More information

DOCUMENTATION PD16 CP3-SVE-M75DC-24

DOCUMENTATION PD16 CP3-SVE-M75DC-24 » User Guide «CPCI Power Supply Manual PRODUCT DOCUMENTATION PD16 CP3-SVE-M75DC-24 Reference ID: 24139 PD16, Rev. 01 February 28, 2011 If it s embedded, it s Kontron. PD16: CP3-SVE-M75DC-24 CPCI Power

More information

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate 1 919 1919P01 1919P03 QBM65/C, QBM75-1U/C Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate QBM751-1/C QBM65/C QBM75/C Highly accurate measurements with calibration

More information

Cable Plug acc. to DIN EN 175301-803, Form A

Cable Plug acc. to DIN EN 175301-803, Form A Cable Plug acc. to DIN EN 175301-803, Form A Complete program Contact form 18 mm Also available with LED indicator Optional 4-pin version for pressure switch or impulse valves respectively Versions with

More information

CompactLogix Power Supplies Specifications

CompactLogix Power Supplies Specifications Technical Data CompactLogix Power Supplies Specifications 1768 CompactLogix Power Supplies Catalog Numbers 1768-PA3, 1768-PB3 1769 Compact I/O Power Supplies Catalog Numbers 1769-PA2, 1769-PB2, 1769-PA4,

More information

Digital input modules

Digital input modules 8 172 TX-I/O Digital input modules TXM1.8D TXM1.16D Two fully compatible versions: TXM1.8D: 8 inputs, each with a three-color LED (green, yellow or red) TXM1.16D: As TXM1.8X, but 16 inputs, each with a

More information

Power Thyristor TS3 (SP) 3ph. Installation Guide

Power Thyristor TS3 (SP) 3ph. Installation Guide Power Thyristor TS3 (SP) 3ph Installation Guide L1 L2 L3 TS3 (SP) 3ph Contents: 1. General Discription 2. Set up of power thyristor TS3 (SP) 3ph 3. Installation 4. Meaning of terminal connectors 5. Description

More information

HP ProLiant DL380 G6 Carrier-Grade Server Read Before Install

HP ProLiant DL380 G6 Carrier-Grade Server Read Before Install HP ProLiant DL380 G6 Carrier-Grade Server Read Before Install Carrier-Grade Instructions HP Part Number: AM275-9001A Published: July 2012 Edition: 3 Copyright 2009, 2012 Hewlett-Packard Development Company,

More information

RM17TE 183...528 V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

RM17TE 183...528 V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC Characteristics multifunction control relay RM17-TE - range 183..528 V AC Complementary Reset time Maximum switching voltage Minimum switching current Maximum switching current [Us] rated supply voltage

More information

MIC-WKT and MIC-WKT-IR

MIC-WKT and MIC-WKT-IR MIC-WKT and MIC-WKT-IR Installation Manual Bosch Security Systems EN Installation and Operation Manual MIC-WKTI and MIC-WKT-IR Installation Manual EN 2 MIC-WKT and MIC-WKT-IR Washer Pump Drive Card Kits

More information

1SFC170011M0201 EN, Rev C. Arc Guard System, TVOC-2 Installation and maintenance guide

1SFC170011M0201 EN, Rev C. Arc Guard System, TVOC-2 Installation and maintenance guide EN, Rev C Arc Guard System, TVOC-2 Installation and maintenance guide Original instruction This is the Installation and maintenance guide for Arc Guard System Type TVOC-2. Document number: Revision: B

More information

PB accessories. PB accessories. Labelling option. Order Information B4-2728. Printed board handle A BZA42727 BZA42724.

PB accessories. PB accessories. Labelling option. Order Information B4-2728. Printed board handle A BZA42727 BZA42724. Printed board handle A Assembly behind front panels Only use printed board handle in conjunction with printed board retainer A (6087-097) Insertion and extraction function Labelling option B4-2728 Item

More information

Quick Connect. quick - simple - efficient. www.g-mw.de

Quick Connect. quick - simple - efficient. www.g-mw.de Quick Connect quick - simple - efficient www.g-mw.de Phone: +49 9103 7129-0 Fax: +49 9103 7129-207 Innovative connection technology to plug three single-phase current transformers to multifunctional power

More information

DRM75A 230V 20/100A DIN rail single phase two wire energy meter

DRM75A 230V 20/100A DIN rail single phase two wire energy meter DRM75A 230V 20/100A DIN rail single phase two wire energy meter 1.1 Safety instruction 1.2 Foreword 1.3 Performance criteria 1.4 Specifications 1.5 Basic errors 1.6 Description 1.7 Dimensions 1.8 Installation

More information

Intersection Preassembled 19-inch Rack

Intersection Preassembled 19-inch Rack Intersection Preassembled 19-inch Rack The intersection preassembled 19-inch rack comes fully assembled, wired and ready to be installed in a server rack. The rack provides communications, power conversion

More information

PSDC 08128. PSDC 12V/8A/8x1A Power supply for up to 8 analog cameras PTC/TOPIC.

PSDC 08128. PSDC 12V/8A/8x1A Power supply for up to 8 analog cameras PTC/TOPIC. PSDC 08128 v.1.2 PSDC 12V/8A/8x1A Power supply for up to 8 analog cameras PTC/TOPIC. EN** Edition: 9 from 25.05.2015 Supersedes the edition: 8 from 12.12.2014 the 8x 1A/12V DC power output for powering

More information

Catalog. Arc Guard System TM TVOC-2

Catalog. Arc Guard System TM TVOC-2 Catalog Arc Guard System TM TVOC-2 Introduction An even better Arc Guard System TVOC-2, ABB s latest Arc Monitor, builds on the well known TVOC design. Its new functions and features improve an already

More information

PowerFlex 700H and 700S AC Drives Frame 11 Main Fan Capacitor Replacement Kit

PowerFlex 700H and 700S AC Drives Frame 11 Main Fan Capacitor Replacement Kit Installation Instructions PowerFlex 700H and 700S AC Drives Frame 11 Main Fan Capacitor Replacement Kit ATTENTION: The sheet metal cover and mounting screws on the ASIC Board located on the power structure

More information

HSP GmbH Zum Handwerkerhof 2 90530 Wendelstein Tel. 09129 / 2852-0 Fax: 09129 / 2852-11 Web: www.hsshsp.de EMAIL: [email protected] NTG-3000.

HSP GmbH Zum Handwerkerhof 2 90530 Wendelstein Tel. 09129 / 2852-0 Fax: 09129 / 2852-11 Web: www.hsshsp.de EMAIL: HSP@hsshsp.de NTG-3000. NTG-3000 Transducer Data Sheet Document Version 2.8 Page 1 of 10 Versions / Revisions: Document Creation Author Description version date 2.0 2012-07-25 P. Compensis First official version 2.1 2012-08-24

More information

Power Supplies 3. SDN-P DIN Rail Series

Power Supplies 3. SDN-P DIN Rail Series SDN-P DIN Rail Series The SDN DIN Rail power supplies provide industry leading performance. Sag Immunity, transient suppression and noise tolerant, the SDN series ensures compatibility in demanding applications.

More information

How To Read A Pipe From A Sensor

How To Read A Pipe From A Sensor Liquid Level Sensor Installation on pipes. Sensing by means electrostatic capacity and is not influenced by the color of the pipe or liquid. Available in 8 to mm dia. and to mm dia. models to enable sensing

More information

LED...A70..4-..Q Series Sealed High-Intensity

LED...A70..4-..Q Series Sealed High-Intensity LED...A70..4-..Q Series Sealed High-Intensity Area Lights High-Power Lighting for use with PresencePLUS and Other Vision Systems Features Rugged, waterproof housing, rated IEC IP68 Compact area light for

More information

LOGO!Power. Power supply. LOGO!Power. Overview. Safety instructions. Description, device design, dimension drawing. Mounting/disassembly

LOGO!Power. Power supply. LOGO!Power. Overview. Safety instructions. Description, device design, dimension drawing. Mounting/disassembly Overview Safety instructions 1 Power supply Operating Instructions Description, device design, dimension drawing 2 Mounting/disassembly 3 Mounting position, mounting clearances 4 Installation 5 Technical

More information

ACS-CRM CONTROL AND MONITORING MODULES FOR USE WITH THE RAYCHEM ACS-30 SYSTEM INSTALLATION INSTRUCTIONS

ACS-CRM CONTROL AND MONITORING MODULES FOR USE WITH THE RAYCHEM ACS-30 SYSTEM INSTALLATION INSTRUCTIONS AS-RM ONTROL AND MONITORING MODULES FOR USE WITH THE RAYHEM AS-0 SYSTEM INSTALLATION INSTRUTIONS APPROVALS/ERTIFIATIONS Hazardous Locations lass I, Div., Groups A,B,,D Ex n II T5 lass I, Zone, AEx n II

More information

Electronic ballasts for fluorescent lamps Products for special applications. PC BASIC, 4 28 W Electronic ballast for system output < 25 W

Electronic ballasts for fluorescent lamps Products for special applications. PC BASIC, 4 28 W Electronic ballast for system output < 25 W T5 TC-DEL TC-SEL TC-TEL TC-DD PC BASIC, 4 28 W Electronic ballast for system output < 25 W Product description CELMA Energy Efficiency Index A2 / A3 Nominal life time up to 50,000 h (at ta 50 C with a

More information

Installation and Operating Instructions for ROBA -takt Control Unit Type 014.000.2

Installation and Operating Instructions for ROBA -takt Control Unit Type 014.000.2 Manufacturer s Declaration This product is intended f installation in a machine system, based on the machine directive 006/4/EC. It is fbidden to start use of the product until the machine system into

More information

INSTALLATION MANUAL. AC/DC Power Supply

INSTALLATION MANUAL. AC/DC Power Supply INSTALLATION MANUAL AC/DC Power Supply Thrane & Thrane A/S AC/DC Power Supply Installation Manual Document number: 98-129099-C Release date: February 26, 2010 Disclaimer Any responsibility or liability

More information

Emergency lighting units EM powerled

Emergency lighting units EM powerled M BASIC 1 W Combined emergency lighting Driver 1 4 W Product description Emergency lighting Driver for manual testing SEV for output voltage < 60 V DC ow-profile casing (21 x 30 mm cross-section) 5-year

More information

MTE SERIES RLW. World REACTORS USER MANUAL PART NO. INSTR 030 REL. 090930. 2009 MTE Corporation

MTE SERIES RLW. World REACTORS USER MANUAL PART NO. INSTR 030 REL. 090930. 2009 MTE Corporation MTE SERIES RLW World REACTORS USER MANUAL PART NO. INSTR 030 REL. 090930 2009 MTE Corporation IMPORTANT USER INFORMATION NOTICE MTE Series RLW reactors are components designed to improve the reliability

More information

HP UPS R1500 Generation 3

HP UPS R1500 Generation 3 HP UPS R1500 Generation 3 Installation Instructions Part Number 650952-001 NOTE: The rating label on the device provides the class (A or B) of the equipment. Class B devices have a Federal Communications

More information

Installation. Smart-UPS VT MGE Galaxy 3500. Maintenance Bypass Panel. 10-40 kva 400 V

Installation. Smart-UPS VT MGE Galaxy 3500. Maintenance Bypass Panel. 10-40 kva 400 V Installation Smart-UPS VT MGE Galaxy 3500 Maintenance Bypass Panel 10-40 kva 400 V Contents Safety.................................................. 1 Save these instructions...................................

More information

Floodlight Range Installation Guide

Floodlight Range Installation Guide SPARTAN Floodlight Range Installation Guide CML13ATEX3007 IEC Ex CML14.0001 This installation guide provides instructions for installing the Infra-Red and White-Light SPARTAN SPX series of explosion protected

More information

ELECTRONICS G H I J K L M

ELECTRONICS G H I J K L M ELECTRONICS TM LASER INSTALLATION INSTRUCTIONS PARTS KIT Parts Kit includes the following: A- (1) Universal Mounting Bracket A B- (1) Red L.E.D. Laser Alert Light C- (1) Piezo Beeper w/ O Ring Tape D-

More information

PLUGS & RECEPTACLES. INNOVATIVE EXPLOSION PROTECTION by R. STAHL 1-800-782-4357

PLUGS & RECEPTACLES. INNOVATIVE EXPLOSION PROTECTION by R. STAHL 1-800-782-4357 Series Features: Color coding and pin configuration makes it physically impossible to mate plugs and receptacles of different voltages and current ratings (per IEC 60 309-2). Interlocked switch mechanism

More information

HM-W536 Install Guide

HM-W536 Install Guide HM-W536 Install Guide 9/13/2013 IMPORTANT SAFETY INSTRUCTIONS Warning - When using electrical devices, basic safety precautions should be followed to reduce the risk of fire, electrical shock or injury.

More information

LevelOne IFE-0500 4-Port PoE + 1-Port TP Industrial Fast Ethernet Switch User Manual

LevelOne IFE-0500 4-Port PoE + 1-Port TP Industrial Fast Ethernet Switch User Manual LevelOne IFE-0500 4-Port PoE + 1-Port TP Industrial Fast Ethernet Switch User Manual Ver. 1.0.0-0711 1 FCC Warning This Equipment has been tested and found to comply with the limits for a Class-A digital

More information

ABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG 110 084 R0011

ABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG 110 084 R0011 , 2CDG 110 084 R0011 2CDC 071 112 F0008 The Fan Coil Actuator is a modular installation device (MDRC) in pro M design. It is intended for installation in the distribution board on 35 mm mounting rails.

More information

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application. 1SR 430 824 F9300 Features Monitoring of three-phase mains for phase sequence and failure Powered by the measuring circuit 2 c/o (SPDT) contacts 1 LED for status indication Approvals R: yellow LED - relay

More information

The power module is Feature Number 8800-F2-901.

The power module is Feature Number 8800-F2-901. Hotwire 8820 GranDSLAM AC to DC Power Supply Installation Instructions Document Number 8800-A2-GZ41-00 AC to DC Power Supply The AC to DC Power Supply consists of a power supply chassis and one or two

More information

Chrome DIN Rail Power Supply 12V 54W 1 Phase (Class II & NEC Class 2) / DRC-12V60W1AG

Chrome DIN Rail Power Supply 12V 54W 1 Phase (Class II & NEC Class 2) / DRC-12V60W1AG Highlights & Features Protection Class II, Double Isolation (No Earth connection is required) Universal AC input voltage and full power up to 55 C Power will not de-rate for the entire input voltage range

More information

HFE1600 Series 1600W 1U Hot Swap Front End Power Supplies

HFE1600 Series 1600W 1U Hot Swap Front End Power Supplies 25.2W/in 3 power density Internal ORing MOSFET & Current Share Climate Savers Computing efficiency standards Up to 8000W in 1U rack Single and dual output 1U racks PMBus option HFE1600 Series 1600W 1U

More information

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors Unit features Safety features Gertebild ][Bildunterschrift_NOT_Sch.tuer_Licht Safety relay for monitoring E-STOP pushbuttons, safety gates and light beam devices Approvals Gertemerkmale Positive-guided

More information

VLT Series 3500 Adjustable Frequency Drive Instruction Manual

VLT Series 3500 Adjustable Frequency Drive Instruction Manual Adjustable Frequency Drive Instruction Manual VLT Series 3500 Instruction Manual 175R5237 - Document Version 5.00 This manual applies to all VLT Series 3502-3800 Adjustable Frequency Drives with software

More information

AI120 AIswitch Series 120 Chassis

AI120 AIswitch Series 120 Chassis AI120 AIswitch Series 120 Chassis Guide INSTALLATION GUIDE Westell Technologies Part # 030-300715 Rev. A Copyright 2015 by Westell Technologies. All Rights Reserved. Westell, Kentrox and Optima Management

More information

Kit 106. 50 Watt Audio Amplifier

Kit 106. 50 Watt Audio Amplifier Kit 106 50 Watt Audio Amplifier T his kit is based on an amazing IC amplifier module from ST Electronics, the TDA7294 It is intended for use as a high quality audio class AB amplifier in hi-fi applications

More information

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592. * see variants. Applications.

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592. * see variants. Applications. Safety Technique SAFEMASTER Emergency Stop Module BG 5924, IP 5924 Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592 BG 5924 IP 5924 Product Description

More information

DMX2PWM 9 Channel Dimmer Setup Manual

DMX2PWM 9 Channel Dimmer Setup Manual DMX2PWM 9 Channel Dimmer Setup Manual www.ecue.de DMX2PWM 9ch Dimmer - Setup Manual e:cue control GmbH An OSRAM Company Rev. 1.3_01/2010 DMX2PWM 9ch Dimmer - Setup Manual Table of Contents 1. Device Overview....................................4

More information

INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks

INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks Securitron Magnalock Corp. www.securitron.com ASSA ABLOY, the global leader Tel 800.624.5625 [email protected] in door opening solutions INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate

More information

INFRARED QUARTZ WALL HEATER

INFRARED QUARTZ WALL HEATER INFRARED QUARTZ WALL HEATER MODEL NO: IQ2000 PART NO: 6939004 MOUNTING & OPERATION INSTRUCTIONS GC0715 INTRODUCTION Thank you for purchasing this CLARKE Infrared Wall Heater. Before attempting to use this

More information

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact Data sheet Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact The CT-AHD.12 is an electronic time relay with OFF-delay. It is from the CT-D range. With their MDRC profile and a width of only

More information

OPL BASIC. Dosing System for Professional Laundry machines. Contents

OPL BASIC. Dosing System for Professional Laundry machines. Contents OPL BASIC Dosing System for Professional Laundry machines Contents 1 Getting Started. Page 2 2 Installation. Page 4 3 Set Up & Operation. Page 8 4 Maintenance & Accessories. Page 10 5 Troubleshooting Page

More information