Actuator-Sensor-Interface

Save this PDF as:
 WORD  PNG  TXT  JPG

Size: px
Start display at page:

Download "Actuator-Sensor-Interface"

Transcription

1 Selection and ordering data Design Order No. Price Pack 3RX AA00 3RX AA00 4FD AA10-1A 3RX AA00 3RX AA00 Single output IP 65 current 2.4 A Rated input voltage DC 24 V current 4 A current 3 A limited Class 2 per UL 1310 and NEC article 725 (selectable) current 3 A limited Class 2 per UL 1310 and NEC article 725 (selectable) Dual output IP 20 current 4/4 A (switchable) Combination output IP 20 1 x DC 24 V / 1 x DC 30 V current 5/4 A (switchable) 1 x DC 24 V / 1 x DC 30 V current 7 A Rated input voltage AC 120/130 V with integrated earth-fault detection current 2.4 A 1 unit Unit 3RX AA00 1 3RX AA00 1 4FD AB40-1A 1 4FD AB30-1A 1 3RX AA00 1 3RX AA00 1 6EP AL EP AL01 16/126 Discount Code: AS-Interface

2 current 2.4 A current 4 A current 3.3 A 3RX AA0 3RX AA0 4FD AA10-1A Rated input voltage in V AC 115/230 (selectable) AC 115/230 AC 230/400 (repositionable) Input Single-phase AC Single-phase AC Single- and two-phase AC Range selection by changeover switch by plug 1 Voltage range in V AC / AC Overvoltage strength EN Mains buffering in ms at I e Rated > 20 > 20 at 230 V; > 60 at 400 V Mains frequency rated value I range in Hz 50/60/ Built-in input fuse in A T 2 T 5 (not accessible) T 3 (not accessible) Recommended m.c.b (IEC 898) from 16 characteristic C in mains supply circuit Rated voltage U a Rated in V DC 30 Total tolerance in V DC ( khz, AS-i+/AS-i-) ( khz, AS-i+/AS-i-) Rated current value I a Rated in A 2.4 (power boost: 2.8) 4 (power boost: 4.5) DC 3.3 (power boost: DC 4) Efficiency at U a Rated, I a Rated in % approx. 85 Power loss at U a Rated, I a Rated in W approx. 10 approx. 18 approx. 15 Overvoltage protection of outputs no Current limitation in A > 2.8 > 4.5 > 5 Primary/secondary isolation SELV to EN SELV to EN SELV to EN (in preparation) class (EN /IEC 950) I Protection IP 20 Approvals CE, UL, ship building CE, UL, CSA (in preparation) CE, UL (in preparation) Emitted interference EN Ambient temperature range in C Transport and storage temperature range in C Humidity class max. 80% rel. humidity Input connection Cage Clamp connection ( mm 2 ) connection AS-Interface + Cage Clamp connection ( mm 2 ) connection AS-Interface - Cage Clamp connection ( mm 2 ) connection shield S Cage Clamp connection ( mm 2 ) connection Ground Cage Clamp terminals ( mm 2 ) Dimensions (W x H x D) in mm Weight in kg approx Mounting Snap-on mounting onto standard rail DIN EN x 7.5 mm Mounting onto standard mounting rail 16/127

3 Dual output IP 20 2 DC 30 V Combination output IP 20 1 DC 24 V / 1 DC 30 V 3RX AA00 current in A 4/4 5/4 Input voltage in V Input Range selection AC 115/230 (selectable) Single-phase AC by changeover switch Input voltage range in V AC / Overvoltage strength EN Mains buffering in ms at I e Rated > 20 Mains frequency rated value I range in Hz 50/60/ Built-in input fuse in A T 5 (not accessible) 3RX AA00 Rated voltage U a Rated in V 2 x DC 30 DC 30/DC 24 Total tolerance DC DC /DC 24 ± 2 % ( khz, AS-Interface+/AS-Interface-) ( khz, AS-Interface+/AS-Interface-) Rated current value I a Rated in A 2x4 4/5 Efficiency at U a Rated, I a Rated in % approx. 85 Power loss at U a Rated, I a Rated in W approx. 36 Overvoltage protection of outputs no Current limitation in A > 4 (power boost 4.5) > 4/> 5 (power boost 4.5 / 5.5) Primary/secondary isolation SELV to EN SELV to EN (in preparation) class (EN /IEC 950) 1 Protection IP 20 Approvals CE, UL, CSA CE, UL, CSA (in preparation) Emitted interference EN Ambient temperature range in C Transport and storage temperature range in C Humidity class max. 80% rel. humidity Input connection Cage Clamp connection ( mm 2 ) connection AS-Interface + Cage Clamp connection ( mm 2 ) connection AS-Interface - Cage Clamp connection ( mm 2 ) connection shield S Cage Clamp connection ( mm 2 ) Dimensions (W x H x D) in mm 150 x 135 x 107 Weight in kg approx. 2 Mounting Snap-on mounting onto standard rail DIN EN x 7.5 mm 16/128

4 with integrated earth-fault detection 6EP A01 current in A Rated input voltage in V AC AC 115/230 Input Range selection by variable range input by changeover switch Voltage range in V AC / DC AC / Overvoltage strength VDE 0160 Limiting curve W2 EN Mains buffering in ms at I e Rated < 20 at 93/187 V > 20 Mains frequency rated value I range in Hz 0/50/60/ Built-in input fuse in A T 6.3 (not accessible) T 2 Recommended circuit-breakers (IEC 898) in A 16 with Characteristic C or 8 with Characteristic B Rated voltage U a Rated in V DC 30 Total tolerance DC ( khz, AS-Interface+/AS-Interface-) ( khz, AS-Interface+/AS-Interface-) Rated current value I a Rated in A (power boost: 2.8) Efficiency at U a Rated, I a Rated in % > 85 Power loss at U a Rated, I a Rated in W < Overvoltage protection of outputs no Current limitation in A from approx. 7.4 > 2.8 Stabilized current characteristic approx. 7.4 A Primary/secondary isolation SELV to EN class (EN /IEC 950) Class I to IEC Protection IP 20 to EN IP 20 Approvals CE, UL/cUL CE, UL, CSA (in preparation) Emitted interference EN , EN Cl. B EN Ambient temperature range in C Transport and storage temperature range in C Humidity class F to DIN max. 80% rel. humidity Input connection 1 terminal each for mm 2 Cage Clamp connection ( mm 2 ) connection AS-Interface + 3 terminals for mm 2 Cage Clamp connection ( mm 2 ) connection AS-Interface - 3 terminals for mm 2 Cage Clamp connection ( mm 2 ) connection shield S 2 terminals for mm 2 Cage Clamp connection ( mm 2 ) Dimensions (W x H x D) in mm Weight in kg Mounting for snap-on mounting onto standard rail Snap-on mounting onto standard rail DIN EN mm and S7 rail DIN EN x 7.5 mm Additional function Integrated 3RK KE00-0AA2 earth fault detection module and isolation of the AS-Interface voltage with corresponding circuit 16/129

5 Actuator-Sensor-Interface Dimension drawings 3RX AA00 3RX AA g_nsa_xx_00121b 3RX AA00, 3RX AA g_nsa_xx_00122b g_nsa_de_00123b 6EP AL01 g_nsa_de_00124b 16/130

is then retained absolutely without interruption.

is then retained absolutely without interruption. Page 1 of 11 DC UPS uninterruptible power supplies - DC UPS module 15 A Compact design, only 50 mm wide Absolutely interruption-free buffering of power failures through immediate electronic connection

More information

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1 Power Supply Unit, Primary Switched, Narrow Design MINI POWER provides: Extra narrow design with widths of 22.5 mm, 45 mm, and 67.5 mm (0.886, 1.772, and 2.657 in.) Global use due to a wide-range input

More information

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: 2868567. DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: 2868567. DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase Extract from the online catalog STEP-PS/1AC/12DC/1.5 Order No.: 2868567 DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase Commercial data EAN 4046356292924 Pack 1 pcs. Customs tariff

More information

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw 4 937 DESIO Current valve for AC 24 V pulse/pause control of electrical loads up to 30 kw SEA45.1 Use The current valve is used for the control of electric heating elements in heating, ventilation and

More information

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages Data sheet Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages The CM-ESS.2 is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of

More information

O WA-120U series IP67. 120W Single Output Switching Power Supply. Features. Aplications

O WA-120U series IP67. 120W Single Output Switching Power Supply. Features. Aplications Features UniversalACinput/Fulrange Built-inactivePFCfunction Higheficiencyupto91% Protections:Shortcircuit/Overcurent/ Overvoltage/Overtemperature Fanlesdesign,colingbyfreairconvection Colingbyfreairconvection

More information

B&R Power Supply PS104

B&R Power Supply PS104 General Information B&R Power Supply PS104 1. General Information Features of the B&R power supply PS104: Output voltage adjustable to 28 V 115/230 V auto select input Overload design (high put overload

More information

Miniature Circuit-Breaker IEC Series 8562

Miniature Circuit-Breaker IEC Series 8562 > 1 to 3 pole versions > Rated current from 0.5... 40 A > 6 or 10 ka breaking capacity to DI VDE 0641, respectively E 60898 > Isolating Function to E 60947-2 > Permanently set thermal and magnetic trips

More information

Three-phase monitoring relay CM-PFE

Three-phase monitoring relay CM-PFE Data sheet Three-phase monitoring relay CM-PFE The CM-PFE is a three-phase monitoring relay that monitors the phase parameter phase sequence and phase failure in three-phase mains. 2CDC 251 005 S0012 Characteristics

More information

Electronic timer CT-TGD.12

Electronic timer CT-TGD.12 2CDC 251 098 F0t06 a Rotary switch for the preselection of the time range of the ON time b Potentiometer with direct reading scale for the fine adjustment of the ON time c Rotary switch for the preselection

More information

Power Supplies 3. SDN-P DIN Rail Series

Power Supplies 3. SDN-P DIN Rail Series SDN-P DIN Rail Series The SDN DIN Rail power supplies provide industry leading performance. Sag Immunity, transient suppression and noise tolerant, the SDN series ensures compatibility in demanding applications.

More information

ETD-SL-1T-DTF. Multifunctional Timer Relay With One Settable Time INTERFACE. Data Sheet. Description

ETD-SL-1T-DTF. Multifunctional Timer Relay With One Settable Time INTERFACE. Data Sheet. Description Multifunctional Timer Relay With One Settable Time INTERFACE Data Sheet PHOENIX CONTACT - 02/2006 Description Multifunctional timer relay with non floating control input and one settable time. The flashing

More information

Quick Connect. quick - simple - efficient. www.g-mw.de

Quick Connect. quick - simple - efficient. www.g-mw.de Quick Connect quick - simple - efficient www.g-mw.de Phone: +49 9103 7129-0 Fax: +49 9103 7129-207 Innovative connection technology to plug three single-phase current transformers to multifunctional power

More information

Product and functional description

Product and functional description Product and functional description The KNX / DALI gateway N 141/02 is a 4 MU wide, DINrail mounted KNX device with one DALI interface to which up to 64 DALI actuators (e.g. DALI ballasts) can be connected

More information

Safety technique. Emergency stop module BO 5988 safemaster

Safety technique. Emergency stop module BO 5988 safemaster Safety technique Emergency stop module BO 5988 safemaster 0221562 Function diagram Pushbutton on Mains or emergencystop () K1 According to EC Directive for machines 98/37/EG According to IEC/E 60204-1

More information

Electronic timer CT-VWE Impulse-ON with 1 c/o (SPDT) contact

Electronic timer CT-VWE Impulse-ON with 1 c/o (SPDT) contact Data sheet Electronic timer CT-VWE Impulse-ON with 1 c/o (SPDT) contact The CT-VWE is an electronic time relay with Impulse-ON function. It is from the CT-E range. The CT-E range is the economic range

More information

Description...: Safety isolating transformer constructed and tested according to VDE 0570/EN , UL 506, CSA 22.2

Description...: Safety isolating transformer constructed and tested according to VDE 0570/EN , UL 506, CSA 22.2 Data sheet: Short Circuit Proof Safety Isolating Transformers AVB ------- Description...: Safety isolating transformer constructed and tested according to VDE 0570/EN 61 558, UL 506, CSA 22.2...: According

More information

PHOENIX CONTACT - 2012-12-14. Features

PHOENIX CONTACT - 2012-12-14. Features Electronic monitoring relay for phase sequence, phase failure, and asymmetry monitoring Data sheet 101748_en_03 1 Description PHOEIX COTACT - 2012-12-14 Features Increasingly higher demands are being placed

More information

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592. * see variants. Applications.

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592. * see variants. Applications. Safety Technique SAFEMASTER Emergency Stop Module BG 5924, IP 5924 Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592 BG 5924 IP 5924 Product Description

More information

VEO. V4PF480Y/277VSYTK02 Art.Nr.: 2104200. V4PF480Y/277VSYTK02P Art.Nr.: 2104210 TECHNICAL DATA

VEO. V4PF480Y/277VSYTK02 Art.Nr.: 2104200. V4PF480Y/277VSYTK02P Art.Nr.: 2104210 TECHNICAL DATA Monitoring of phase sequence and phase loss Monitoring of asymmetry Temperature monitoring (PTC) Supply voltage 208-480 V AC Supply circuit = measuring circuit 2 change-over contacts Width 45 mm Control

More information

Chrome DIN Rail Power Supply 12V 54W 1 Phase (Class II & NEC Class 2) / DRC-12V60W1AG

Chrome DIN Rail Power Supply 12V 54W 1 Phase (Class II & NEC Class 2) / DRC-12V60W1AG Highlights & Features Protection Class II, Double Isolation (No Earth connection is required) Universal AC input voltage and full power up to 55 C Power will not de-rate for the entire input voltage range

More information

DeltaV Bulk Power Supplies

DeltaV Bulk Power Supplies DeltaV Distributed Control System Product Data Sheet DeltaV Bulk Power Supplies DeltaV 5 A,10 A, 20 A and 40 A Bulk Power Supplies DeltaV 20 A, 40 A and 80 A Bulk Power Supply Redundancy Modules. Easy

More information

Redundancy Module QUINT-DIODE/40

Redundancy Module QUINT-DIODE/40 Redundancy Module QUT DIODE provides: 00% decoupling of power supplies connected in parallel Can be installed in potentially explosive areas Load currents up to 60 A supported Easy assembly by snapping

More information

RM4TG20 three-phase network control relay RM4-T - range 200..500 V

RM4TG20 three-phase network control relay RM4-T - range 200..500 V Characteristics three-phase network control relay RM4-T - range 200..500 V Complementary [Us] rated supply voltage Output contacts Setting accuracy of time delay Delay at power up Measuring cycle Marking

More information

PCB transformers. Short circuit proof PCB transformer VB. General Data. Advantages. Applications. Circuit diagram. Standards & 1 Certifications W v

PCB transformers. Short circuit proof PCB transformer VB. General Data. Advantages. Applications. Circuit diagram. Standards & 1 Certifications W v Short circuit PCB transformer General Data Rated input 230 Vac Rated output 6-2 x 24 Vac Rated power 0.35-3.2 VA Insulation class B Maximum ambient temperature 70 C Efficiency up to 58 % Degree of protection

More information

DLA starters General information

DLA starters General information General information The construction of is based on ABB A Line contactors. The mounting plate, including a built-in A contactor, is designed to integrate an ABB manual motor starter type MS325. Starters

More information

Industrial Power Supplies

Industrial Power Supplies , Features For industrial, office and residential applications Ultracompact plastic housing Connection by spring clamp terminals or detachable screw terminal block Reliable snap-on mounting on DIN-rails

More information

RM17TE 183...528 V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

RM17TE 183...528 V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC Characteristics multifunction control relay RM17-TE - range 183..528 V AC Complementary Reset time Maximum switching voltage Minimum switching current Maximum switching current [Us] rated supply voltage

More information

Electronic timer CT-VBS.17+18 OFF-delayed without auxiliary voltage, for DC contactors Data sheet

Electronic timer CT-VBS.17+18 OFF-delayed without auxiliary voltage, for DC contactors Data sheet Characteristics Single-function OFF-delay timer for DC contactors, without auxiliary voltage Width.5 mm CDC 5 6 F3 Approvals A culus E CCC CT-VBS a Circuit diagram b Marker label Marks a CE b C-Tick Order

More information

Control Devices Catalogue. Control Devices. Preferred and Standard Products

Control Devices Catalogue. Control Devices. Preferred and Standard Products Control Devices Catalogue Control Devices Preferred and Standard Products KOP.J Timer Electronic 22.5 mm Characteristics Mounting KOP.J 22.5 mm mono or multifunction high immunity to interference surface

More information

Data sheet: Safety isolating transformers type APT

Data sheet: Safety isolating transformers type APT Data sheet: Safety isolating transformers type APT -------------------------- Description...: safety isolating transformer constructed and tested according to VDE 0570/EN 61 558 ; UL506 ; CSA 22.2 Test

More information

Related catalogs. Trademarks ITC. Training for Information and Industrial Solutions 1) The offline Mall of Automation and Drives KT 10.

Related catalogs. Trademarks ITC. Training for Information and Industrial Solutions 1) The offline Mall of Automation and Drives KT 10. Catalog KT 10.1 2004 SITOP Power supplies Catalog KT 10.1 2004 sitop Power supplies SITOP power LOGO!Power Related catalogs System Cabling SIMATIC TOP connect KT 10.2 Training for Information and Industrial

More information

RHINO PSM Series Power Supplies

RHINO PSM Series Power Supplies RHINO PSM Series Supplies Our versatile switching power supplies are DIN-rail mountable Features Industrial grade design Sturdy metal case to withstand harsh industrial environments Model PSM4-090S-N meets

More information

Description... : Safety isolating transformer constructed and tested according to VDE 0570/EN , UL 506, CSA 22.2

Description... : Safety isolating transformer constructed and tested according to VDE 0570/EN , UL 506, CSA 22.2 Data sheet: Safety Isolating Transformers VCM ------------------------------------- Description... : Safety isolating transformer constructed and tested according to VDE 0570/EN 61 558, UL 506, CSA 22.2...

More information

MINI MCR-SL-UI-UI-NC. Extract from the online catalog. Order No.:

MINI MCR-SL-UI-UI-NC. Extract from the online catalog. Order No.: Extract from the online catalog MINI MCR-SL-UI-UI-NC Order No.: 2864150 MCR 3-way isolating amplifier for electrical isolation of analog signals, input/output configurable via DIP switch, with screw connection,

More information

DS 600. A contact free flux gate based current measurement sensor 600A rms

DS 600. A contact free flux gate based current measurement sensor 600A rms DS 600 A contact free flux gate based current measurement sensor 600A rms DS 600 is member of the small housing sensor family. The family includes a 200A and a 600A version. 600A rms - 900A peak Maximum

More information

Type: DILM32 10(24V50HZ) Article No.: 277247

Type: DILM32 10(24V50HZ) Article No.: 277247 Type: DILM32 10(24V50HZ) Article No.: 277247 Ordering information Rated operational current AC 3 400 V I e A 32 Max. rating for three phase motors, 50 60 Hz AC 3 230 V Max. rating for three phase motors,

More information

MTE RLW Reactors Price book

MTE RLW Reactors Price book Table of Contents TABLE OF CONTENTS...1 STANDARD DELIVERY SCHEDULE...2 SELECTION & APPLICATION GUIDE...3 SPECIFICATION DATA...4 SERVICE FACTOR...4 AMBIENT TEMPERATURE...4 APPROVALS...4 ENCLOSURES:...4

More information

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages Data sheet Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages The CM-ESS.M is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of

More information

Measuring and monitoring relays CM-MSS (4), CM-MSS (5) Thermistor motor protection relays

Measuring and monitoring relays CM-MSS (4), CM-MSS (5) Thermistor motor protection relays Data sheet Measuring and monitoring relays CM-MSS (4), Thermistor motor protection relays The devices CM-MSS (4) and (5) are used to monitor the overload of motors by the wiring temperature. The motors

More information

Preset Counter signo 721

Preset Counter signo 721 Most simple handling Impressive, clearly readable display in 48x48 mm Input frequency up to 60 khz Easy installation due to pluggable terminals TECHNICAL DATA GENERAL Display Height of digits Supply voltage

More information

MONITORING RELAYS. w VOLTAGE MONITORING RELAY UR5U1011. w SCHRACK-INFO. w TECHNICAL DATA

MONITORING RELAYS. w VOLTAGE MONITORING RELAY UR5U1011. w SCHRACK-INFO. w TECHNICAL DATA w VOLTAGE MONITORING RELAY UR5U1011 w SCHRACK-INFO AC/DC voltage monitoring in 1-phase mains Undervoltage monitoring 1 change over contact Width 17.5 mm Installation design w TECHNICAL DATA 502 1. Functions

More information

Data sheet: Safety isolating transformers type FL

Data sheet: Safety isolating transformers type FL Data sheet: Safety isolating transformers type FL -------------------------- Description... : safety isolating transformer according to VDE 0570/EN 61558 UL 506; CSA 22.2 Test voltage... PRI - SEC 5000

More information

Model EPS240-12 EPS240-24 EPS240-48. Rated Power: 240W 240W 240W. >0,98 for 115V AC full load, >0,94 for 230V AC full load

Model EPS240-12 EPS240-24 EPS240-48. Rated Power: 240W 240W 240W. >0,98 for 115V AC full load, >0,94 for 230V AC full load EPS240 Series Single Phase Primary Switch DC Power Supply Unit Universal AC/DC Input Easily Din Rail Installation High Reliability And Durability LED Indicator For Functions Control I. Technical Data Model

More information

SITOP power supply. Technical data. SITOP Power Supply. Answers for industry.

SITOP power supply. Technical data. SITOP Power Supply. Answers for industry. SITOP power supply Technical data SITOP Power Supply Answers for industry. Selection table SITOP power supplies Input voltage Output current modular smart LOGO!Power Special design, SIMATIC design Others

More information

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features Central 48 V DC Power Supplies for PoE-Components MICROSENS Description Active network equipment which is supporting the Power-over-Ethernet functions, typically requires a powerful 48 V DC power supply.

More information

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER Application : The RISH CON - Hz transducer is used for frequency measurement. The output signal is proportional to measured frequency and is either load independent DC Current or load independent DC Voltage.

More information

AC/DC Power Modules C B. TML Series, 20 & 40 Watt. Features. 20 Watt Models

AC/DC Power Modules C B. TML Series, 20 & 40 Watt. Features. 20 Watt Models TML Series, 0 & 0 Watt Features C B Scheme LVD UL 090- Encapsulated power supplies with increased power density Replaces TML and TML 0 series PCB mount or chassis mount with screw terminals Single, dual

More information

Three-phase monitoring relay CM-PVE

Three-phase monitoring relay CM-PVE Data sheet Three-phase monitoring relay CM-PE The three-phase monitoring relay CM-PE monitors the phase parameter phase failure as well as over- and undervoltage in three-phase mains. 2CDC 251 006 S0012

More information

ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories

ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories 2CDC 251 014 F0t09 Features Monitoring of three-phase mains for grid feeding Type-tested in accordance with DIN V VDE V 0126-1-1: February 2006 Neutral conductor connection configurable Can also be used

More information

Chrome DIN Rail Power Supply 24V 30W 1 Phase (Class II & NEC Class 2) / DRC-24V30W1AZ

Chrome DIN Rail Power Supply 24V 30W 1 Phase (Class II & NEC Class 2) / DRC-24V30W1AZ Highlights & Features Protection Class II, Double Isolation (No Earth connection is required) Universal AC input voltage without power de-rating Efficiency > 87.0% @ 115Vac & 230Vac NEC Class 2 / Limited

More information

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information. Product and Applications Description The power supply units N 125/x2 can supply DC 24 V power from an additional pair of terminals (yellowwhite). This DC 24 V output voltage can be used to power e.g. an

More information

Thermistor motor protection

Thermistor motor protection Thermistor motor protection CM-E Range Thermistor motor protection Thermistor motor protection relays Benefits and advantages Selection table Operating principle and fields of application for thermistor

More information

Type: DILM9 10(24VDC) Article No.: 276705

Type: DILM9 10(24VDC) Article No.: 276705 Type: DILM9 10(24VDC) Article No.: 276705 Ordering information Rated operational current AC 3 400 V I e A 9 Max. rating for three phase motors, 50 60 Hz AC 3 230 V Max. rating for three phase motors, 50

More information

Example of use: Fuse for a solenoid valve. If the fuse is defective, no information is sent to the electronic component.

Example of use: Fuse for a solenoid valve. If the fuse is defective, no information is sent to the electronic component. Overview Switch and button modules The dimensions of the switch and button modules are adapted to the electronic components in the integral housing. The modules are equipped with the universal clip-on

More information

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages Data sheet Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages The CM-ESS.2 is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of

More information

Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated. Ordering information

Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated. Ordering information Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated Ordering information Connection technique Description Description Rated operational current Screw terminals 3 pole AC

More information

Electronic Circuit Breaker ESS20-0...

Electronic Circuit Breaker ESS20-0... Description Electronic circuit breaker type ESS0-0.. is designed to ensure selective disconnection of individual loads in systems which are powered by a DC 4 V switch-mode power supply. DC 4 V power supplies,

More information

Power Supply IC690PWR024, CE690PWR024, IC690PWR124, CE690PWR124

Power Supply IC690PWR024, CE690PWR024, IC690PWR124, CE690PWR124 October, 1998 Introduction Power Supply IC690PWR024, CE690PWR024, IC690PWR124, CE690PWR124 24 VDC Power Supply These switching power supplies have features that make them useful and reliable in a wide

More information

ELFA E90S MINI BREAKERS

ELFA E90S MINI BREAKERS ELFA E90S MINI BREAKERS - ELFA E90S SERIES UL Approved (UL1077) 10KA INTERUPTION CAPACITY OPTIONS FIELD KITS Auxiliary Contacts Alarm Contact Shunt Trip UV Trip Current Limiting Design (Class 3) 3 Different

More information

Chrome DIN Rail Power Supply 12V 10W 1 Phase (Class II & NEC Class 2) / DRC-12V10W1AZ

Chrome DIN Rail Power Supply 12V 10W 1 Phase (Class II & NEC Class 2) / DRC-12V10W1AZ Highlights & Features Protection Class II, Double Isolation (No Earth connection is required) Universal AC input voltage and full power up to 55 C Power will not de-rate for the entire input voltage range

More information

Thermistor motor protection relays CM-MSS.22 and CM-MSS.23

Thermistor motor protection relays CM-MSS.22 and CM-MSS.23 Data sheet Thermistor motor protection relays CM-MSS.22 and CM-MSS.23 The thermistor motor protection relays CM-MSS.22 and CM-MSS.23 monitor the winding temperature of motors and protect them from overheating,

More information

Assembly. Front view. Switch S1. Power Rail

Assembly. Front view. Switch S1. Power Rail Temperature Repeater Features Assembly 1-channel isolated barrier V DC supply (Power Rail) Resistance and RTD input (Pt100, Pt500, Pt1000) Resistance output Accuracy 0.1 % Line fault detection (LFD) for

More information

RM35UA13MW. range 15..600 V. Main. Product or component type. Relay monitored parameters

RM35UA13MW. range 15..600 V. Main. Product or component type. Relay monitored parameters Characteristics multifunction voltage control relay RM35-U - range 15..600 V Complementary Reset time Maximum switching voltage [Us] rated supply voltage Supply voltage limits Power consumption in W Main

More information

Relés e Contatores de Estado Sólido SIRIUS

Relés e Contatores de Estado Sólido SIRIUS Relés e Contatores de Estado Sólido SIRIUS Coletânea de dados técnicos ( product data sheet ) Agosto/212 SSR - 3RF21 22,5 mm Ponto Zero SSR - 3RF2 45 mm Ponto Zero SSR - 3RF22 45 mm Ponto Zero Trifásico

More information

Type: DILM50(230V50HZ,240V60HZ) Article No.: 277830

Type: DILM50(230V50HZ,240V60HZ) Article No.: 277830 Type: DILM50(230V50HZ,240V60HZ) Article No.: 277830 Ordering information Rated operational current AC 3 400 V I e A 50 Max. rating for three phase motors, 50 60 Hz AC 3 230 V Max. rating for three phase

More information

RM17UAS. Main. Product or component type. Product specific application. Relay monitored parameters

RM17UAS. Main. Product or component type. Product specific application. Relay monitored parameters Characteristics voltage control relay RM17-U - range 65..260 V AC Complementary Reset time Maximum switching voltage [Us] rated supply voltage Supply voltage limits Power consumption in W Main Range of

More information

3753 en - 04.2004/b VE/B - VE/RG Va V riable speed drives

3753 en - 04.2004/b VE/B - VE/RG Va V riable speed drives 3753 en 04.2004/b Variable speed drives LEROYSOMER's drives provide SPEED VARIATION for a DC motor, SIMPLY and ECONOMICALLY from a singlephase power supply. CMStype technology is used. These products conform

More information

Chrome DIN Rail Power Supply 24V 91.2W 1 Phase (Class II & NEC Class 2) / DRC-24V100W1AZ

Chrome DIN Rail Power Supply 24V 91.2W 1 Phase (Class II & NEC Class 2) / DRC-24V100W1AZ Highlights & Features Protection Class II, Double Isolation (No Earth connection is required) Universal AC input voltage without power de-rating Efficiency > 87.0% @ 115Vac, > 89.0% @ 230Vac NEC Class

More information

Overview Expansion modules for the connection to LOGO! Modular With digital inputs and outputs, analog inputs or analog outputs

Overview Expansion modules for the connection to LOGO! Modular With digital inputs and outputs, analog inputs or analog outputs expansion modules Overview Expansion modules for the connection to LOGO! Modular With digital inputs and outputs, analog inputs or analog outputs Technical specifications Supply voltages 1CB00-0BA0 1HB00-0BA0

More information

LOGO!Power. Power supply. LOGO!Power. Overview. Safety instructions. Description, device design, dimension drawing. Mounting/disassembly

LOGO!Power. Power supply. LOGO!Power. Overview. Safety instructions. Description, device design, dimension drawing. Mounting/disassembly Overview Safety instructions 1 Power supply Operating Instructions Description, device design, dimension drawing 2 Mounting/disassembly 3 Mounting position, mounting clearances 4 Installation 5 Technical

More information

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact Data sheet Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact The CT-AHD.12 is an electronic time relay with OFF-delay. It is from the CT-D range. With their MDRC profile and a width of only

More information

Power Supply, Primary Switch Mode, Narrow Design MINI-PS-100-240AC/2x15DC/1

Power Supply, Primary Switch Mode, Narrow Design MINI-PS-100-240AC/2x15DC/1 Power Supply, Primary Switch Mode, Narrow Design -PS-100-240AC/2x15DC/1 POWER provides: Extra narrow widths of 22.5 and 45 mm (0.886 and 1.772 in.) Global use due to a wide range input A high level of

More information

Pluggable interface relays CR-P Pcb relays

Pluggable interface relays CR-P Pcb relays 2CDC 293 034 F0004 1 2 4 3 Features 9 different supply s: DC versions: 12 V, 24 V, 48 V, 110 V AC versions: 24 V, 48 V, 110 V, 120 V, 230 V Output contacts: 1 c/o (16 A) or 2 c/o (8 A) Cadmium-free contact

More information

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application. 1SR 430 824 F9300 Features Monitoring of three-phase mains for phase sequence and failure Powered by the measuring circuit 2 c/o (SPDT) contacts 1 LED for status indication Approvals R: yellow LED - relay

More information

LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A - 220 V AC coil

LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A - 220 V AC coil Product data sheet Characteristics LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 -

More information

ABB i-bus KNX Switch Actuator, x-fold, 16 A, MDRC SA/S x.16.2.1, 2CDG1101xxR0011

ABB i-bus KNX Switch Actuator, x-fold, 16 A, MDRC SA/S x.16.2.1, 2CDG1101xxR0011 Technical Data 2CDC505051D0205 ABB i-bus KNX Product description Switch Actuators SA/S x.16.2.1, 16 A are modular installation devices in ProM design for installation in the distribution board. They are

More information

RM4TR32 three-phase network control relay RM4-T - range V

RM4TR32 three-phase network control relay RM4-T - range V Characteristics three-phase network control relay RM4-T - range 300..430 V Complementary [Us] rated supply voltage Control threshold undervoltage Control threshold overvoltage Output contacts Main Range

More information

LOGO!Power. Power supply. LOGO!Power. Overview. Description, device design, dimension drawing. Mounting/Disassembly 2

LOGO!Power. Power supply. LOGO!Power. Overview. Description, device design, dimension drawing. Mounting/Disassembly 2 Overview Description, device design, dimension drawing 1 Power supply Operating Instructions Mounting/Disassembly 2 Mounting position, installation clearances 3 Installation 4 Applications 5 Technical

More information

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller Overview/Modes of Operation Bulletin 150 Smart Motor Controller The SMC-3 is a compact, simple to use, solid-state motor controller designed to operate 3-phase motors. It features a built-in overload relay

More information

RE7TL11BU on-delay timing relay s - 24 V AC DC - 1OC

RE7TL11BU on-delay timing relay s - 24 V AC DC - 1OC Characteristics on-delay timing relay - 0.05..1 s - 24 V AC DC - 1OC Main Commercial Status Range of product Product or component type Component name Time delay type Time delay range [Us] rated supply

More information

Control transformers STN..., DTZ Multi-winding transformer UTI

Control transformers STN..., DTZ Multi-winding transformer UTI Control transformers STN..., DTZ Multi-winding transformer UTI Multipurpose power supply units AING All transformers are constructed and tested according to IEC/EN 61558 guidelines. Depending on version,

More information

SINEAX U553 Transducer for AC Voltage

SINEAX U553 Transducer for AC Voltage With power supply RMS value measurement Carrying rail housing P/0 Application he transducer SINEAX U55 (Fig. ) converts a sinusoidal or a distorted AC voltage into a load independent DC current or a load

More information

Technical catalogue. Modular DIN rail components Installation contactors

Technical catalogue. Modular DIN rail components Installation contactors Technical catalogue Modular DIN rail components Installation contactors Installation Contactors Overview... ESB Installation Contactors 0 A / AC-/AC-7a ESB0...4 4 A / AC-/AC-7a ESB4...5 40 A / AC-/AC-7a

More information

ABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG 110 084 R0011

ABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG 110 084 R0011 , 2CDG 110 084 R0011 2CDC 071 112 F0008 The Fan Coil Actuator is a modular installation device (MDRC) in pro M design. It is intended for installation in the distribution board on 35 mm mounting rails.

More information

Siemens AG 2014. Inputs 8 8 8 8 of which can be used 4 (0 to 10 V) 4 (0 to 10 V)

Siemens AG 2014. Inputs 8 8 8 8 of which can be used 4 (0 to 10 V) 4 (0 to 10 V) 8 Basic 24CE 12/24RCE 24RCE 230RCE Inputs 8 8 8 8 of which can be used 4 (0 to 10 V) 4 (0 to 10 V) in analog mode Input/supply voltage 24 V DC 12...24 V DC 24 V AC/DC 115...230 V AC/DC Permissible range

More information

RLW Reactors Technical Reference Manual

RLW Reactors Technical Reference Manual Form: RLW-TRM-E Rel: March 2011 Form RLW-TRM-E March 2011 Page 1 Table of Contents STANDARD DELIVERY SCHEDULE... 3 SELECTION & APPLICATION GUIDE... 4 MODEL CODE PART NUMBER CONFIGURATION... 5 RL REACTOR

More information

MAJORSINE Power Inverter

MAJORSINE Power Inverter MAJORSINE Power Inverter Product Features: 24, 48, 130 V 1 KVA/800 Watts Output 2 KVA/1600 Watts Output 100-120 VAC Range 208-240 VAC Range Standard 19 /23, Pure Sine Wave Output High Low EMI/RFI Emissions

More information

Thermistor motor protection relays CM-MSS.22 and CM-MSS.23

Thermistor motor protection relays CM-MSS.22 and CM-MSS.23 Data sheet Thermistor motor protection relays CM-MSS.22 and CM-MSS.23 The thermistor motor protection relays CM-MSS.22 and CM-MSS.23 monitor the winding temperature of motors and protect them from overheating,

More information

BB800 Off-Grid Solar System

BB800 Off-Grid Solar System BB800 Off-Grid Solar System KEY PRODUCT FEATURES Control Box & Charge Controller 1000W of Solar Panels 4x200Ah of SLA Batteries in series 2KW Inverter Output Power Solar Panel & Battery Mounting Our entry

More information

Instruction Manual VLT 5000

Instruction Manual VLT 5000 Instruction Manual VLT 5000 Contents Safety 4 Safety regulations 5 Warning against unintended start 5 Installation of mechanical brake 5 Technical data 6 General technical data 6 Electrical data 13 Fuses

More information

TWDLCDA40DRF compact PLC base Twido - 24 V DC supply - 24 I 24 V DC - 16 O

TWDLCDA40DRF compact PLC base Twido - 24 V DC supply - 24 I 24 V DC - 16 O Characteristics compact PLC base Twido - 24 V DC supply - 24 I 24 V DC - 16 O Main Range of product Product or component type Discrete I/O number 40 Discrete input number 24 Discrete input voltage Discrete

More information

R.C.C.B. s two-pole LEXIC

R.C.C.B. s two-pole LEXIC 87045 LIMOGES Cedex Telephone : (+33) 05 55 06 87 87 Fax : (+ 33) 05 55 06 88 88 R.C.C.B. s two-pole LEXIC 089 06/09/10/11/12/15/16/17/18/ 27/28/29/30/35, CONTENTS PAGES 1. Electrical and mechanical characteristics...

More information

2.06. Version. Kinglong New Energy Technology Co.Ltd. Sunteams 1500 Sunteams 3000. Sunteams 4000 Sunteams 5000

2.06. Version. Kinglong New Energy Technology Co.Ltd. Sunteams 1500 Sunteams 3000. Sunteams 4000 Sunteams 5000 Photovoltaic Inverter Specification Version 2.06 1500 2000 3000 4000 5000 Kinglong New Energy Technology Co.Ltd. Kinglong New Energy Technology Co.Ltd. specification 1.1. Introduction... 3 1.1.1. Environment...

More information

Emergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN 60204-1, VDE 0113 Part 1

Emergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN 60204-1, VDE 0113 Part 1 MainswitchSurfacemounting Partno. P3-63/I4/SVB Articleno. 207343 CatalogNo. SP3-063-I4CRQ IP65 Deliveryprogramme Product range Switch-disconnectors Basic function Main switches Maintenance switches Manual

More information

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT ... ... Spur 2. Spur 1. Zone 1. Zone 0

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT ... ... Spur 2. Spur 1. Zone 1. Zone 0 FieldBarrier Features Assembly 8... 12 outputs Ex ia IIC, FISCO and Entity Advanced fault isolation and diagnostics at the spur FieldBarrier in Zone 1/Div. 2 Instruments in Zone 0...1/Div. 1 For FOUNDATION

More information

3RT1015-1BB41 CONTACTOR, AC-3 3 KW/400 V,

3RT1015-1BB41 CONTACTOR, AC-3 3 KW/400 V, Automation Technology > Industrial Controls > Switching Devices > Contactors and Contactor Assemblies > Power Contactors for Switching Motors > Contactors SIRIUS 3RT10, 3-pole, 3... 250 kw 3RT1015-1BB41

More information

Telephone- and leased line modem for industrial applications TD-36

Telephone- and leased line modem for industrial applications TD-36 Telephone- and leased line modem for industrial applications TD-36 Modem for industrial PSTN- and leased line applications The TD-36 is an analogue V.34 PSTN modem as well as an industrial 2-wire leased

More information

Models. Output current max.* Output Power max. Low Line : VAC High Line: VAC 24 VDC / 12 A 240 W. Back up battery

Models. Output current max.* Output Power max. Low Line : VAC High Line: VAC 24 VDC / 12 A 240 W. Back up battery AC/DC Battery Controller Power Supply TSPC-240UPS Series Compact universal 24 VDC power supply with integrated battery controller module Battery protection for over voltage, deep discharge, short circuit

More information

Your automation should be permanently supplied Our compact PROeco power supplies offer that as part of an economical concept Let s connect.

Your automation should be permanently supplied Our compact PROeco power supplies offer that as part of an economical concept Let s connect. Your automation should be permanently supplied Our compact PROeco power supplies offer that as part of an economical concept Let s connect. Power supply Find the cost-effective solution for your power

More information