Soft Start-up Valve Series AV2000/3000/4000/5000

Size: px
Start display at page:

Download "Soft Start-up Valve Series AV2000/3000/4000/5000"

Transcription

1 Soft Start-up Valve Series AV//4/ AV Start-up valve for low speed air supply to gradually raise initial pressure in an air system and for quick exhaust by cutting off air supply. Large effective area (mm ) AV/ (ody size: /4) AV/ 7 (ody size: /8) AV4/ (ody size: /) AV/ (ody size: /4) AV/ (ody size: ) Combination with F.R.L. unit F.R.L. combination Soft start-up valve AV AV AV4 (Except 4-) AV 4 With supply/exhaust function by manual operation Low power consumption Connectable with modular type F.R.L. combination unit F.R.L. combination Soft start-up valve AF AR AL AW A G AV AF8 AF9 4

2 Soft Start-up Valve AV//4/ How to Order Soft start-up valve AV G Flow direction Nil Left to right R Right to left CE compliance Nil Q Compliant Note ) Note ) G, grommet is not available. ody size 4 /4 /8 / /4, Manual override Nil: Non-locking push type (Flush) : Locking type (Tool required) C: Locking type (Lever) Thread type Nil F N 4 Rc G NPT Port size /4 (AV only) /8 (AV only) / (AV4 only) /4 (AV only) (AV only) Nil G Option None With pressure gauge How to Order Pilot Valve Assembly SF4 G 8 Coil rated voltage Light/Surge voltage suppressor Nil S Z V (/ Hz) V (/ Hz) to V (/ Hz) V (/ Hz) 4 VDC VDC 4V (/ Hz) Other None With surge voltage suppressor (Grommet type only) With light/surge voltage suppressor (Not possible with grommet type) Electrical entry G: Grommet Note ) D: Type D DIN terminal (With connector) DO: Type D DIN terminal (Without connector) Y: Type Y DIN terminal (With connector) G D Y DO YO Rated coil voltage V (/ Hz) V (/ Hz) to V (/ Hz) V (/ Hz) 4 VDC VDC 4 V (/ Hz) Other Electrical entry Grommet Note ) Type D DIN terminal (With connector) Type Y DIN terminal (With connector) Type D DIN terminal (Without connector) Type Y DIN terminal (Without connector) Note ) The grommet type can have a surge voltage suppressor (direct coupling type lead wire), but without indicator light. 4 Flow direction Nil Left to right R Right to left Manual override Nil C CE compliance Nil Q Compliant Note ) Note ) G, grommet is not available. Soft start-up valve Non-locking push type (Flush type) Locking type (Tool required) Locking type (Lever type) Light/Surge voltage suppressor Nil None S With surge voltage suppressor (Grommet type only) Z With light/surge voltage suppressor(not possible with grommet type) YO: Type Y DIN terminal (Without connector) Note ) The grommet type can have a surge voltage suppressor (direct coupling type lead wire), but without indicator light.

3 Soft Start-up Valve Series AV//4/ Specifications Type D DIN terminal Model Port size Proof pressure Operating pressure range Pressure gauge port size Ambient and fluid temperature Effective area (P) (A) (mm ) (A) (R) Mass (kg) Rated coil voltage Allowable voltage fluctuation Coil insulation type Apparent power Inrush (Current consumption) Energized Current consumption DC Electrical entry Option specifications Electrical specifications Pilot valve manual override AV /4 4.7 Piston Switching Pressure (Close AV / AV4 /. MPa. to MPa /8 to C () 7.74 AV /4. 4.4,, to, V (/ Hz), 4 V (/ Hz), 4 VDC to +% of rated voltage Equivalent to type ( C). VA ( Hz),. VA ( Hz).4 VA (. W)/ Hz,. VA (. W)/ Hz.8 W Grommet, Type D DIN terminal, Type Y DIN terminal Indicator light/surge voltage suppressor () Non-locking push type (Flush), Locking type (Tool required), Locking type (Lever) Note ) Use dry air when operating at a low temperature. Note ) The grommet type is equipped with a surge voltage suppressor (direct coupling type lead wire), but not an indicator light. Open). Type Y DIN terminal Outlet pressure (MPa) Inlet pressure (MPa) JIS Symbol (P) Accessory/Pressure Gauge Description Part no. Pressure range (R) (A) Pressure gauge G-- MPa Needle Valve Flow Characteristics Air flow rate (l/min (ANR)) Inlet pressure. MPa AV AV4 AV AV 4 Needle rotations 47 AF AR AL AW A G AV AF8 AF9

4 Series AV//4/ Working Principle 4 ON OFF - (P) (A) 7 (R) Working condition Pilot valve Pressure conditions Working description Pressure time chart (Meter-out control) example Cylinder drive circuit (Meter-out control) example Low speed supply High speed supply ON / PP > PA / PP PA When pilot valve is turned ON by energization or manual override, the pilot air pushes piston A and main valve downward and opens main valve while R port closes simultaneously. The air from P port moves to needle valve 7, where its flow is adjusted, and flows to A port. The meter-in control of needle valve 7 slowly moves the cylinder from A to. When / PP PA after the cylinder reaches, piston fully opens and PA increases rapidly as shown from C to D and becomes the same pressure as PP. Initial Operation Return Stroke Pressure stroke A PP PA Cylinder movement with fixed orifice PR (Atmospheric pressure) Time C D PP (P) PP (P) (R) PA (A) PA (A) Normal operation / PP PA Since piston holds the fully open condition, during normal operation the cylinder s speed will be controlled by the usual meter-out control. (R) Quick exhaust OFF When pilot valve is turned OFF, spring 4 pushes piston A and main valve upward and opens R port while shutting off the air supply from P port. The pressure difference generated at this time lets the check valve open and the residual pressure on the A port side is quickly exhausted from R port. (P) PP PA (A) (R) 48

5 Soft Start-up Valve Series AV//4/ Construction ON OFF 9 - (P) (A) (R) Component Parts No. Description ody Cap Cover Material Aluminum die-casted Aluminum die-casted Aluminum die-casted Replacement Parts No Description Pilot valve assembly Piston A assembly Piston assembly Main valve assembly Check valve Piston guide assembly Needle assembly Valve spring Piston spring Check spring Needle spring Type C retaining ring for shaft Type C retaining ring for hole Seal Seal O-ring Material POM, NR rass, NR (HNR) rass, NR (HNR) rass, NR (HNR) POM, NR rass, NR Steel wire Stainless steel Stainless steel Steel wire Tool steel Tool steel NR NR NR For How to Order pilot valve assembly, refer to page 4. AV P444A P44A P44A P447 P448A P449A P44 P44 P44 P444 G- -9 P44 P448 x 8 x Part no. AV AV4 SF4- -8 P444A P4444A P44A P444A P44A P444A P447 P4447 P448A P4448A P449A P4449A P44 P444 P44 P444 P44 P444 P444 P4444 STW- STW-8 - RTW- P44 P444 P44 P444 x 9 x. x 9. x. AV P444A P44A P44A P447 P448A P449A P44 P44 P44 STW- RTW- P44 P444. x. x AF AR AL AW A G AV AF8 AF9 49

6 Series AV//4/ Dimensions Grommet: AV - - G, GS DIN terminal: AV - - D, DZ DIN terminal for European use: AV - - Y, YZ I G A mm (Lead wire length) Manual override (Locking lever type) G L K A M Applicable cab tire cord O.D.: ø, ø8 Manual override (Locking lever type) With light/surge voltage suppressor Pressure gauge mounting bore /8 Port size ON OFF ON OFF Indicator light P Q N ø7 C A H P A Q H C ø7 R P 4 x R.8 E Pressure gauge mounting bore /8 R P 4 x R.8 E D D - + SMC MADE IN JAPAN - + SMC MADE IN JAPAN Model Port size A C D E G H I K L M N P Q R AV- - G AV- - GS AV- - D AV- - DZ AV- - Y AV- - YZ AV- - G AV- - GS AV- - D AV- - DZ AV- - Y AV- - YZ AV4-4- G AV4-4- GS AV4-4- D AV4-4- DZ AV4-4- Y AV4-4- YZ AV- - G AV- - GS AV- - D AV- - DZ AV- - Y AV- - YZ /4 /4 /4 /8 /8 /8 / / / /4, /4, /4, M4 x.7 Depth 4. M4 x.7 Depth 4. M4 x.7 Depth 4. M x.8 Depth M x.8 Depth M x.8 Depth M x Depth M x Depth M x Depth M x Depth 7. M x Depth 7. M x Depth 7. 44

7 Soft Start-up Valve Series AV//4/ Connecting Spacer for Modular Style F.R.L. Unit Select one of the spacers below when connecting to an F.R.L. combination unit ( to ). (Spacers must be ordered separately.) Spacer Spacer with bracket Y Y4 YT Y4T Model Y Y Y4 Y Applicable model AV AV AV4 AV Model YT YT Y4T YT Applicable model AV AV AV4 AV AF AR AL AW A G AV AF8 AF9 44

8 Series AV//4/ Specific Product Precautions e sure to read before handling. Refer to front matters 4 and 4 for Safety Instructions and pages 87 to 9 for F.R.L. Precautions. on Design. Actuator drive When using solenoid valve or actuator in the outlet side of this product, implement appropriate measures to prevent potential danger caused by actuator operation.. Holding pressure Since the valve might have slight interal leakage, it is not suitable for holding pressure in a tank or another vessel for a long period of time.. Maintenance space Allow the sufficient space for maintenance and inspection. Selection. Confirm the specifications. The products presented in this catalog are designed only for use in compressed air systems. Do not operate at pressures or temperatures, etc., beyond the range of specifications, as this can cause damage or malfunction. (Refer to specifications.) Please contact SMC if using for other fluids than compressed air.. Extended periods of continuous energization Please contact SMC if valves will be continuously energized for extended periods of time.. Operation of closed center solenoid valves Even if this product is used for closed center solenoid valves or actuator with a load factor of more then %, jumping (stick-slip phenomenon) cannot be prevented. 4. Using a regulator in the outlet side When mounting a regulator in the outlet side (A port side), use a residual pressure relief regulator (ARK to 4K) or a check type regulator. With a standard regulator (AR to ), the outlet side pressure may not be released when this valve is exhausted.. Operation of solenoid valves in the outlet side To operate solenoid valves mounted on this product s outlet side (A port side), first confirm that the outlet side s pressure (PA) has increased to become equal to the inlet side s pressure (PP).. Operation The residual pressure release function of this product is for emergency use only; therefore, avoid the operation in the same manner as ordinary port valves. 7. Using a lubricator If mounting a lubricator, mount it on the inlet side (P port side), of this product. If mounted on the outlet side (A port side), back flow of oil will occur and may spurt out of the valve s R port. 8. Operation for air blowing This product cannot be operated for air blowing due to the mechanism that switches the main valve to be fully open after the outlet side s pressure increases to approximately / of the inlet side. Selection. Voltage leakage Particularly when using a C-R element (surge voltage suppressor) for protection of the switching element, use cation that leakage voltage will increase due to leakage current flowing through the C-R element, etc. Power supply Switching element OFF Resistor Leakage current coil is % or less of rated voltage. DC coil is % or less of rated voltage.. Low temperature operation Although the valve can be operated at temperature as low as C, measures should be taken to avoid solidifying or freezing drainage and moisture, etc. Leakage voltage Mounting. If air leakage increases or equipment does not operate properly, stop operation. After mounting or maintenance, etc., connect the compressed air and power supplies, and perform appropriate function and leakage tests to confirm that the unit is mounted properly.. Instruction manual Mount and operate the product after reading the manual carefully and understanding its contents. Also keep the manual in a place where it can be referred to as necessary.. Painting and coating s or specifications printed or labeled on a product should not be erased, removed or covered up. Furthermore, please contact SMC before painting the resin parts, as this may cause adverse effects depending on the solvent. Adjustment. To perform the initial speed adjustment of a outlet side actuator, supply air from this valve s inlet side and turn ON the pilot valve. Then, rotate the needle counterclockwise from the fully closed position. Valve 44

9 Series AV//4/ Specific Product Precautions e sure to read before handling. Refer to front matters 4 and 4 for Safety Instructions and pages 87 to 9 for F.R.L. Precautions. Piping. Preparation before piping efore piping is connected, it should be thoroughly blown out by air (flushed) or washed to eliminate cutting chips, cutting oil, and other debris from the pipe inside.. How to wrap a pipe tape When connecting pipes and fittings, etc., ensure that cutting chips and sealing materials from the pipe threads should not get inside the valve. When a pipe tape is used, leave. to thread ridges exposed at the end of the pipe. Winding direction Pipe tape Light/Surge Voltage Suppressor Tightening Torque when Piping Connection threads Rc /4 Rc /8 Rc / Rc /4 Rc Expose approx. threads Voltage and VDC 4 VDC or less Electrical circuit Terminal no. (+) ZNR With indicator light Terminal no. ( ) Terminal no. + ( ) +( ) -(+) Electrical Connection ZNR With indicator light Terminal no. (+) Note) There is no polarity (+ or ) The internal connection of the DIN terminal is as shown below, connect to the power supply side as shown.. Tighten threads with the proper tightening torque. When screwing fittings into valves, tighten with the torques given below. Proper tightening torque (N m) to 4 to 4 8 to 8 to to 8 Terminal DIN terminal DIN terminal + 4. Piping to products When piping to products, avoid making an error of supply port, etc., by referring to the instruction manuals.. F.R.L. module combination When connecting to a modular F.R.L. combinations ( to ), select one of the spacers, which are included. (Refer to page 44 for details.) However, modular combinations with 4- are not possible. Furthermore, connect soft start-up valves to the outlet side of the F.R.L. combination.. Inlet side piping conditions The nominal size of the piping material s or equipment s bore should be equal to or larger than the soft start-up valve s port size. The composite effective area of the inlet side s (P port side s) piping or equipment should be equal to or larger than the values below. Model AV AV AV4 AV Composite effective area (mm ) When the piping is restricted or the supply pressure is insufficient, the main valve will not switch and air leakage may occur from the R port. Lubrication. The valve has been lubricated for life at the factory, and does not require any further lubrication.. Use turbine oil Class, ISO VG (with no additives), if lubricated. esides, if the lubrication is suspended halfway, the original lubricant will be lost and may result in a malfunction. e sure to keep lubricating continuously. Refer to the brand name table given below for lubricants by each company, comforming to turbine oil Class (with no additives), ISO VG. Turbine Oil Class (With no additives), ISO VG Viscosity classification cst (4 C) ISO viscosity grade Idemitsu Kosan Co.,Ltd. Turbine oil P- Turbine oil, Nippon Mitsubishi Oil Corp. Mitsubishi Turbine Cosmo Oil Co.,Ltd. Cosmo turbine Japan Energy Corp. Kyodo turbine Viscosity classification cst (4 C) ISO viscosity grade Kygnus Oil Co. Turbine oil Kyushu Oil Co. Stork turbine Showa Shell Sekiyu K.K. Turbine Tonengeneral Sekiyu K.K. General R turbine Fuji Kosan Co.,Ltd. Fucoal turbine Please contact SMC regarding turbine oil Class (with additives), ISO VG. AF AR AL AW A G AV AF8 AF9 44

10 Series AV//4/ Specific Product Precautions e sure to read before handling. Refer to front matters 4 and 4 for Safety Instructions and pages 87 to 9 for F.R.L. Precautions. Air Supply. Use clean air. Do not use compressed air which contains chemicals, synthetic oils containing organic solvents, salts or corrosive gases, etc., as this can cause damage or malfunction.. Install air filters. Install air filters close to valves at their upstream side. A filtration degree of μm or less should be selected.. Implement countermeasures by installing aftercooler or air dryer, or water separator, etc. The air including excess drain may result in a malfunction of valves and other pneumatic equipment. Implement countermeasures by installing after-cooler or air dryer, or water separator, etc. Operating Environment. Do not use valves in such environments where corrosive gases, chemicals, or brine or water or steam is airborne, or where valves can be directly exposed to any of those.. Do not use in an explosive environment.. Do not use in locations influenced by vibrations or impacts. 4. A protective cover, etc., should be used to shield valves from direct sunlight.. Shield valves from radiated heat generated by nearby heat sources.. Take suitable protective measures in locations where there are contacts with water droplets, oil, or welding spatter, etc. 7. In a dusty environment or when valve switching noise is intrusive, install a silencer in the R port to prevent dust from entering, and to reduce noise. Maintenance. Perform maintenance and inspection as shown in the instruction manual. If handled improperly, damage may occur in machine or equipment or an operational error may result in.. Equipment removal and supply/exhaust of compressed air When equipment is removed, first confirm that measures are implemented to prevent dropping of workpiece and runaway of equipment, etc. Then cut the supply pressure and power, and exhaust all compressed air from the system using its residual pressure release function.. Low frequency operation Valves should be switched at least once every days to prevent malfunction. (Use caution regarding the air supply.) 4. Manual override operation When the manual override is operated, connected equipment will be actuated. Confirm the safety before operating.. Drain removal Remove drain from air filters periodically. How to Find the Flow Rate Choke flow: (P +.)/(P +.). Q = x S x (P +.) x t Subsonic flow: when (P +.)/(P +.) >. Q = 4 x S x (P P)(P +.) x Q: Air flow rate [l/min (ANR)] S: Effective area (mm ) P: Inlet pressure [MPa] P: Outlet pressure [MPa] t: Air temperature [ C] (At air temperature of C) t Note ) Formulas above are applied to pneumatics only. 444

Inrush Apparent power (VA) Flow Characteristics/Weight. Port size Rc. Valve model VS3115-01 VS3115-02 VS3110-02 VS3110-03 VS3114-00.

Inrush Apparent power (VA) Flow Characteristics/Weight. Port size Rc. Valve model VS3115-01 VS3115-02 VS3110-02 VS3110-03 VS3114-00. Port Direct Operated Solenoid Valve Series VS5/0 Metal Seal Multiple pressure supply is possible with balanced spool sleeve. Any given port can accept high or low pressure supply without affecting the

More information

5 Port Pilot Operated Solenoid Valve Rubber Seal. Specifications Fluid Operating pressure range. 2 position single/3 position 2 position double

5 Port Pilot Operated Solenoid Valve Rubber Seal. Specifications Fluid Operating pressure range. 2 position single/3 position 2 position double For details about certified products conforming to international standards, visit us at www.smcworld.com. 5 Port Pilot Operated Solenoid Valve Rubber Seal Series VF3000 Compact and lightweight: 26.4 mm

More information

3 Port Solenoid Valve

3 Port Solenoid Valve Port Solenoid Valve Series V00 Rubber Seal Power consumption 0. W (with power saving circuit) VV0 VV00 V00 -V F VS temperature rises: C (with power saving circuit) Sonic conductance Series Standard Large

More information

Precision Regulator. Series IR1000/2000/3000 ARJ AMR ARM ARP IR IRV VEX1 SRH SRP SRF ARX20 VCHR ITV IC PVQ VER VEA VY2 AP100.

Precision Regulator. Series IR1000/2000/3000 ARJ AMR ARM ARP IR IRV VEX1 SRH SRP SRF ARX20 VCHR ITV IC PVQ VER VEA VY2 AP100. Precision Regulator Series // Basic Type Air Operated Type Series Model Regulating pressure range Page Series Series Series Series Series.5 to MPa. to MPa. to.8 MPa /8 55.5 to MPa. to MPa /4 55. to.8 MPa.

More information

NAMUR Mount Hygienic Valve

NAMUR Mount Hygienic Valve NF097-D NMUR Mount Hygienic Valve For Wash Down pplications Series VFN Features Engineered Plastic PPS Body (Polyphenylene Sulfide) provides high temperature and chemical/corrosion resistance for use in

More information

Direct Operated Regulator for 6.0 MPa (Relieving Type) How to Order. Body size 30 40

Direct Operated Regulator for 6.0 MPa (Relieving Type) How to Order. Body size 30 40 Direct Operated Regulator for (Relieving Type) Series Service life: 0 million cycles Using NSF-H-certified grease on the guide ring (sliding) part. Improved durability under a high environment with a polyurethane

More information

Specifications. Model Flow type Pressure type. Air Maximum operating pressure. 1.0 MPa Ambient and fluid temperature. 3% F.S.

Specifications. Model Flow type Pressure type. Air Maximum operating pressure. 1.0 MPa Ambient and fluid temperature. 3% F.S. Electro-Pneumatic Proportional Valve Series /VEP Electro-pneumatic proportional valve: Flow type () Controls the flow rate steplessly according to current. (It is a / port valve that has an electrical

More information

Standard Specifications Model. How to Order. Mist spray unit. Recommended Equipment. Mixing valve

Standard Specifications Model. How to Order. Mist spray unit. Recommended Equipment. Mixing valve Mist Spray Unit Series MU/ Intermittent spray to cutting and press gear chains, etc. Standard Specifications MU MU Inlet air Oil tank set range. MPa. to. MPa Oil tank capacity (cm ) Total capacity: Effective

More information

3 Port Solenoid Valve

3 Port Solenoid Valve ubber Seal ort Solenoid Valve Series SYJ00/00/700 [Option] SYJ VQZ V VG Improved pilot valve ilot valve cover is stronger using stainless steel. Mounting thread is also reinforced from size M1.7 to M.

More information

5.0 MPa Pilot Operated 2/3 Port Solenoid Valve & Check Valve

5.0 MPa Pilot Operated 2/3 Port Solenoid Valve & Check Valve 5.0 Ma ilot Operated /3 ort Solenoid Valve & Check Valve Series VCH VCH4/4: ort VCH40: 3 ort VCHC40: Check Valve ilot Operated ort Solenoid Valve [Option] Series VCH40 Stable responsiveness Response time

More information

5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported. Flow characteristics 1 4/2 (P A/B) 4/2 5/3 (A/B R1/R2)

5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported. Flow characteristics 1 4/2 (P A/B) 4/2 5/3 (A/B R1/R2) For details about certified products conforming to international standards, visit us at www.smcworld.com. 5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported Model position position Type of actuation

More information

Water Separator. Main Line Filter. Mist Separator. Micro Mist Separator 150C 250C 350C 450C AMG 550C 2C 4C 8C 11C AFF 22C 37B 75B 150C 250C 350C 450C

Water Separator. Main Line Filter. Mist Separator. Micro Mist Separator 150C 250C 350C 450C AMG 550C 2C 4C 8C 11C AFF 22C 37B 75B 150C 250C 350C 450C Water droplet removal Water Separator Water droplet separation rate: % Model Flow capacity l/min (ANR) Max. flow capacity at 0.7 MPa inlet pressure 300 750 1,500 AMG 2,0 AMG to AMG/ Large dust particle

More information

0.35 0.9. 3 Port Solenoid Valve. Series VQZ100/200/300. Compact, High Flow. Power consumption: 0.35 W/0.9 W SYJ VQZ VP VG VP3

0.35 0.9. 3 Port Solenoid Valve. Series VQZ100/200/300. Compact, High Flow. Power consumption: 0.35 W/0.9 W SYJ VQZ VP VG VP3 Port Solenoid Valve 00/00/00 Metal Seal Rubber Seal 0. 0.9 (Standard) (High pressure type, High speed response type) Power consumption: 0. W/0.9 W Compact, High Flow Body ported Base mounted 00 00 00 00

More information

4/2-Way Pneumatic Solenoid Valve

4/2-Way Pneumatic Solenoid Valve 4/2-Way Pneumatic Solenoid Valve Robust servo assisted piston valve Service friendly manual override Single or block assembly Explosion-proof versions Type 5413 cam be combined with Type 2508 Cable plug

More information

Process Valve. 2 Port Valve For Compressed Air and Air-hydro Circuit Control

Process Valve. 2 Port Valve For Compressed Air and Air-hydro Circuit Control Process Valve Series VN Port Valve For Compressed ir and ir-hydro Circuit Control Exclusively for air pressure system and air-hydro circuit control Universal Port Valve [Option] Cylinder actuation by external

More information

3 WAY (3/2) POPPET VALVES FOR AIR AND VACUUM SERVICE SOLENOID OR AIR ACTUATED BROCHURE N-223

3 WAY (3/2) POPPET VALVES FOR AIR AND VACUUM SERVICE SOLENOID OR AIR ACTUATED BROCHURE N-223 3 WAY (3/2) POPPET VALVES FOR AIR AND VACUUM SERVICE SOLENOID OR AIR ACTUATED BROCHURE N-223 HERION S HIGH PERFORMANCE POPPET VALVES For those applications requiring high Cv, fast response times, large

More information

CAT.ES120-4 A. Precision Clean Regulator. Series SRP. High precision, low flow consumption stainless steel regulator

CAT.ES120-4 A. Precision Clean Regulator. Series SRP. High precision, low flow consumption stainless steel regulator CAT.ES120-4 A Precision Clean Regulator Series SRP High precision, low flow consumption stainless steel regulator Precision Clean Regulator Series SRP High precision, low flow consumption stainless steel

More information

2 position single. (Standard) 100V AC 50/60Hz 200V AC 50/60Hz 24V DC. 2 position double

2 position single. (Standard) 100V AC 50/60Hz 200V AC 50/60Hz 24V DC. 2 position double 4/ Port Solenoid Valve Rubber Seal VZ1000/000/000 Solenoid Valve Variations Port Size Effective area (mm 2 ) Position solenoid Voltage Electrical entry Option/ Indicator light and surge voltage suppressor

More information

SOLENOID VALVES AND PNEUMATIC VALVES

SOLENOID VALVES AND PNEUMATIC VALVES 2 A S E R I E S Catalogue 2005-2006 Directly operated solenoid valves Series A 2/2 way, 3/2 way monostable, bistable (with magnetic memory) Ports M5,, cartridge ø4 The Series A solenoid valves are of the

More information

Hydraulic control unit series 0086-372-01

Hydraulic control unit series 0086-372-01 Technical Product Information No. 1290 EN Hydraulic control unit series 0086-372-01 Contents Page About this Technical Product Information (TPI) 2 The ORTLINGHAUS numbering system 2 About the product 3

More information

Unit 24: Applications of Pneumatics and Hydraulics

Unit 24: Applications of Pneumatics and Hydraulics Unit 24: Applications of Pneumatics and Hydraulics Unit code: J/601/1496 QCF level: 4 Credit value: 15 OUTCOME 2 TUTORIAL 4 DIRECTIONAL CONTROL VALVES The material needed for outcome 2 is very extensive

More information

System 8. ü www.nassmagnet.com ( +49 511 6746-0. System 8

System 8. ü www.nassmagnet.com ( +49 511 6746-0. System 8 System 8 ü www.nassmagnet.com ( +9 11 7-0 System 8 The name System 8 stands for a modular system of solenoid coils, armature systems, solenoid operators and solenoid valves. The diameter of the armatures

More information

3/2-way Solenoid Valve, direct-acting, NC or NO

3/2-way Solenoid Valve, direct-acting, NC or NO 3/2-way Solenoid Valve, direct-acting, NC or NO Electrical connection cable plug, Form A With or without manual override as standard Threaded port and sub-base s Impulse optional Type 6014 can be combined

More information

% ^ ) 0.55 W Low Power Solenoid Valves Aluminum, Brass, or Stainless Steel Bodies 1/4" to 1" NPT. 2/2 3/2 4/2 5/2 5/3 SERIES Low Power

% ^ ) 0.55 W Low Power Solenoid Valves Aluminum, Brass, or Stainless Steel Bodies 1/4 to 1 NPT. 2/2 3/2 4/2 5/2 5/3 SERIES Low Power .55 W Solenoid Valves Aluminum, Brass, or Stainless Steel Bodies /" to " NPT / 3/ / 5/ 5/3 Features Molded one-piece solenoid with highly efficient solenoid cartridge and.55 W low wattage coil Standard

More information

Mustang Series PRESSURE REDUCING CONTROL VALVE WITH PRESSURE SUSTAINING FEATURE. M115-2 (Globe) M1115-2 (Angle) Schematic. Standard Components

Mustang Series PRESSURE REDUCING CONTROL VALVE WITH PRESSURE SUSTAINING FEATURE. M115-2 (Globe) M1115-2 (Angle) Schematic. Standard Components Schematic Throttles to reduce high upstream pressure to constant lower downstream pressure Throttles to maintain minimum upstream pressure PRESSURE REDUCING CONTROL VALVE WITH PRESSURE SUSTAINING FEATURE

More information

Universal type. Elbow type AS13 1FG-M5 AS23 1FG-01 AS23 1FG-02 AS33 1FG-02 AS33 1FG-03 AS43 1FG-04. Specifications

Universal type. Elbow type AS13 1FG-M5 AS23 1FG-01 AS23 1FG-02 AS33 1FG-02 AS33 1FG-03 AS43 1FG-04. Specifications Speed Controller with One-touch Fitting Stainless Steel Series Elbow Type/Universal Type Series -FG RoHS Stainless specifications for use in corrosive environments. Stainless steel used for metal parts.

More information

Sensors. Sensors. All Cylinders. Specifications. Features: Features Type REED HALL EFFECT NPN or PNP. Ø8mm - 125mm

Sensors. Sensors. All Cylinders. Specifications. Features: Features Type REED HALL EFFECT NPN or PNP. Ø8mm - 125mm Specifications Features Type REED HALL EFFECT NPN or PNP Applicable Series Configurations Construction Materials Body Mounting Bracket Cable Characteristics Operating Temperature Accuracy All Cylinders

More information

Wear Resistant Tubing

Wear Resistant Tubing Wear Resistant Tubing 1/ brasion: pprox. (Compared with SMC polyurethane tubing TU series) 3 6-color variations Description Wear resistant tubing TUZ series Polyurethane tubing TU series Green RoHS Maximum

More information

PBX Series Quick Fit Connector Bimetallic Steam Traps

PBX Series Quick Fit Connector Bimetallic Steam Traps 6262100/6 IM-P626-01 ST Issue 6 PBX Series Quick Fit Connector Bimetallic Steam Traps Installation and Maintenance Instructions 1. Safety information 2. General product information 3. Installation 4. Commissioning

More information

2/2 and 3/2 Way Size 6 Seat Valves

2/2 and 3/2 Way Size 6 Seat Valves 2/2 and 3/2 Way Size 6 Seat Valves Directly operated Interface and subplate dimensions according to DIN 24340 and ISO Line connection port size G 3/8" Cartridge design PN [p max. ] = 315 bar 7501856.06.12.08

More information

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics 3/2-, 5/2-5/3-way Solenoid Valves for process pneumatics Type 6518 stard High flow-rate capacity Reduced power consumption Single or manifold mounting stard Type 6518/6519 can be combined with... Stard-,

More information

3/2-way Mini Solenoid Valve

3/2-way Mini Solenoid Valve 3/2way Mini Solenoid Valve Directacting 0... bar DN mm... DN mm,,, subbase, banjobolt connection 21mm coil spacing when mounted on manifold Type can be combined with... Type 20 Type 207 Type able plug

More information

UM/22000 5/2 & 5/3 valves, solenoid and pilot actuated ISO 5599-1, ISO size 1, 2, 3 & 4 Sub-base mounted

UM/22000 5/2 & 5/3 valves, solenoid and pilot actuated ISO 5599-1, ISO size 1, 2, 3 & 4 Sub-base mounted U/ / & / valves, solenoid and pilot actuated ISO 99-, ISO size,, & Sub-base mounted Steel reinforced main seals 6 bar and bar NOO solenoid pilots with locking or non-locking manual override Low power coils

More information

PRESSURE REDUCING CONTROL VALVE

PRESSURE REDUCING CONTROL VALVE Schematics Throttles to reduce high upstream pressure to constant lower downstream pressure Low Flow By-Pass controls at low flows 4 PRESSURE REDUCING CONTROL VALVE with LOW FLOW BY-PASS FEATURE Main Line

More information

SECTION G2: CABLE PROCESSOR MODULE MAINTENANCE

SECTION G2: CABLE PROCESSOR MODULE MAINTENANCE SECTION G2: CABLE PROCESSOR MODULE MAINTENANCE Cable Processor Module overview WARNING! When tipping the Cable Processor Module back, (after removing the toggle arm pin), use extreme caution not to drop

More information

No. : EX##-OMF0004 OPERATION MANUAL. SI unit EX12#-SMB1

No. : EX##-OMF0004 OPERATION MANUAL. SI unit EX12#-SMB1 No. : EX##-OMF0004 OPERATION MANUAL EX12#-SMB1 Contents 1. Safety instructions ------------------------------------------------------ P3 2. Notes ------------------------------------------------------

More information

SPOOL & SLEEVE VALVES solenoid air operated monostable / bistable function threaded ports G 1/8-G 1/4

SPOOL & SLEEVE VALVES solenoid air operated monostable / bistable function threaded ports G 1/8-G 1/4 SPOO & SV VAVS monostable / bistable function threaded ports -G 1/ 5/-5/3 Series 1 FATURS Reliability: steel spool & sleeve technology with long service life Robust valve design, particularly recommended

More information

Fleck 4650. Service Manual INSTALLATION AND START-UP PROCEDURE TABLE OF CONTENTS JOB SPECIFICATION SHEET

Fleck 4650. Service Manual INSTALLATION AND START-UP PROCEDURE TABLE OF CONTENTS JOB SPECIFICATION SHEET Fleck 4650 Service Manual TABLE OF CONTENTS JOB SPECIFICATION SHEET...1 INSTALLATION AND START-UP PROCEDURE...1 CONTROL VALVE DRIVE ASSEMBLY...2 CONTROL DRIVE ASSEMBLY FOR CLOCK...3 BYPASS VALVE ASSEMBLY...4

More information

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv) Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv) Order code Series and function 1) Plug socket see page 5.042. MN-06-310-HN-442 Standard coil 1) 441 = 12 V DC, 4.2 W 442 = 24 V DC,

More information

5 Port Solenoid Valve

5 Port Solenoid Valve Metal Seal ort Solenoid Valve Series VQ7-6/7-8 Rubber Seal ISO Standard Size /Size VQ7-8/Single unit.6 VQ7-8/Manifold. Conforms to ISO standard /I Interface conforms to ISO standard Size (VQ7-6) and Size

More information

Assisted lift operated 2/2-way solenoid valves Type EV250B

Assisted lift operated 2/2-way solenoid valves Type EV250B MAKING MODERN LIVING POSSIBLE Data sheet Assisted lift operated 2/2-way solenoid valves Type EV250B EV250B with assisted lift can operate from zero and up to 10 bar differential pressure. This 2/2-way

More information

3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve

3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve 3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve Type 6518 Type 6519 Type 6518/6519 can be combined with... Single or block mounting Suitable for outdoor and chemical atmospheres Suitable for

More information

type V46, solenoid or pneumatic operated

type V46, solenoid or pneumatic operated SPECIFICATION general type of construction spool valve operator solenoid or pneumatic operated or by manual override. Manual override is equipped with a monostable function (push) and a bistable function

More information

3-Way heavy duty flow control, with pressure compensated and solenoid controlled priority flow

3-Way heavy duty flow control, with pressure compensated and solenoid controlled priority flow 1/6 RE 18309-3/06.10 Replaces: RE 18309-3/04.10 3-Way heavy duty flow control, with pressure compensated and solenoid controlled priority flow A-VRFC3C-VEI-VS 0M.43.20.80 - Y - Z Description The flow control

More information

Unit 24: Applications of Pneumatics and Hydraulics

Unit 24: Applications of Pneumatics and Hydraulics Unit 24: Applications of Pneumatics and Hydraulics Unit code: J/601/1496 QCF level: 4 Credit value: 15 OUTCOME 2 TUTORIAL 2 HYDRAULIC AND PNEUMATIC CYLINDERS The material needed for outcome 2 is very extensive

More information

TABLE OF CONTENTS. SECTION 1 General Information: Pg 2 Description of Operation

TABLE OF CONTENTS. SECTION 1 General Information: Pg 2 Description of Operation GTRDD SERIES HEATLESS DRYER INSTALLATION, OPERATION & MAINTENANCE MANUAL TABLE OF CONTENTS SECTION 1 General Information: Pg 2 Description of Operation SECTION 2 Safety Instructions: Pg 3 Installation

More information

UM/22000 5/2 or 5/3 Solenoid and air pilot actuated soft spool valves

UM/22000 5/2 or 5/3 Solenoid and air pilot actuated soft spool valves U/ / or / > > Sub-base mounted, 99- s,, or > > Steel reinforced main seals > > Low power coils (,W) > > Wide range of sub-bases and accessories > > 6 bar and bar NOO solenoid pilots with locking or non-locking

More information

On-off valves MS-EM/EE, MS series, NPT

On-off valves MS-EM/EE, MS series, NPT On-off valves MS-EM/EE, MS series, NPT On-off valves MS9-EM, MS series, NPT Peripherals overview 5 3 4 aa -H- Note Additional accessories: Module connector for combinations with size MS6, MS9 or size MS12

More information

Fluid. Flu. Fluid Fluid. uid Power d Power P. Fluid Power P. Fluid Power. Fluid Power Power. d Power. Directional Cetop Valves DCV 03.

Fluid. Flu. Fluid Fluid. uid Power d Power P. Fluid Power P. Fluid Power. Fluid Power Power. d Power. Directional Cetop Valves DCV 03. Catalogue Directional Cetop Valves DCV 03 Power Flu uid Power d Power P wer Power Power Power Power Power d Power Power Power ower Power Power wer Power Power P Power Power Powe d Power Power Power Power

More information

Directional seated valves type VP 1

Directional seated valves type VP 1 Directional seated valves type VP 1 zero leakage, intended for general hydraulic applications and grease lubing systems Flow Q max Operation pressure p max = 15 lpm = 400 bar Individual valve Individual

More information

Cartridge Valves. Solenoid Valves. Vickers. Screw-in Cartridge Valves. Maximum Pressure 210 bar (3000 psi) Maximum Flow 227 l/min (60 USgpm)

Cartridge Valves. Solenoid Valves. Vickers. Screw-in Cartridge Valves. Maximum Pressure 210 bar (3000 psi) Maximum Flow 227 l/min (60 USgpm) Vickers Cartridge Valves Solenoid Valves Screw-in Cartridge Valves Maximum Pressure bar ( psi) Maximum Flow 7 l/min (6 USgpm) Rev /99 77 Introduction For over seventy years, Vickers has provided its customers

More information

Single sub-base valve

Single sub-base valve solenoid valves Mini-valves 10 mm Electrical connection... Mounting... Port sizes... Rated temperature... Fluid... Working pressure... Nominal flow... Pneumatic connections Voltage... Power... NC poppet

More information

Chapter 6: Check Valves

Chapter 6: Check Valves Contents Chapter : Check Valves Series Description Size Mounting Page Parker Standard DIN / ISO 1/8 1/4 3/8 1/2 3/4 1 0 10 1 25 32 Shuttle valves SSR -2 Check valves, direct operated RK / R CS SPZE SPV

More information

G1/4 Q8. Standard with biased position

G1/4 Q8. Standard with biased position Contents Version Actuation Page Characteristics Dimensions x / Way Valves pneumatic 6,7, 0 9 electric 6,7 9, 9 / Way Valves pneumatic 6,7, 0 electric 6,7, 0 / Way Valves pneumatic 6,7,, 6, 7 electric 6,7,,

More information

SKP Series SKP15U.. Gas Valve Actuator with Safety Shutoff Function

SKP Series SKP15U.. Gas Valve Actuator with Safety Shutoff Function SKP Series SKP15U.. Gas Valve Actuator with Safety Shutoff Function Document No. 155-751 SKP15U.. Description Only when assembled to Series VGU Gas valves SKP15 electro-hydraulic actuators combine with

More information

WHAT YOU DON T KNOW ABOUT ACCUMULATORS CAN KILL YOU!

WHAT YOU DON T KNOW ABOUT ACCUMULATORS CAN KILL YOU! WHAT YOU DON T KNOW ABOUT ACCUMULATORS CAN KILL YOU! Atlanta (Monroe) GA 770-267-3787 gpm@gpmhydraulic.com www.gpmhydraulic.com What You Don t Know About Hydraulic Accumulators Can Kill You TABLE OF CONTENTS

More information

4 Posiflow Proportional Solenoid Valves

4 Posiflow Proportional Solenoid Valves 4 Posiflow Solenoid Brass or Stainless Steel Bodies 1/4" to 1/2" NPT 2/2 Features Flow rates adjustable between 0% and 100% of rating Flow rate can also be regulated by a range of electrical inputs (sensors,

More information

Oil and Coolant Circulating Heating System. Model - OCSM

Oil and Coolant Circulating Heating System. Model - OCSM Oil and Coolant Circulating Heating System Model - OCSM Installation & Operation Manual 216280-000 REV 2 Identifying Your System The HOTSTART heating system is designed to heat fluids for use in marine

More information

Check Valves. Pilot Operated Check Valves. Vickers. PCGV-6/8, 10 Series; PCG5V-6/8, 20 Series. Typical Section. Features and Benefits

Check Valves. Pilot Operated Check Valves. Vickers. PCGV-6/8, 10 Series; PCG5V-6/8, 20 Series. Typical Section. Features and Benefits Vickers Check Valves Pilot Operated Check Valves PCGV-6/8, 10 Series; PCG5V-6/8, 20 Series Typical Section Typical PCG5V model with internally drained pilot piston internal leakage through the closed pilot

More information

Product Manual. CVS Type 67AFR Filter Regulator. Introduction. Installation. Description

Product Manual. CVS Type 67AFR Filter Regulator. Introduction. Installation. Description Product Manual CVS Type 67AFR Filter Regulator Introduction This CVS Controls product manual includes instructions for the installation, adjustment, maintenance and parts ordering of the CVS Type 67AFR

More information

Hydraulic Air Riveter. Operation Manual RC197 RC198. Recommend for mass production line industrial area. Page 1

Hydraulic Air Riveter. Operation Manual RC197 RC198. Recommend for mass production line industrial area. Page 1 Hydraulic Air Riveter Recommend for mass production line industrial area Operation Manual RC197 RC198 Page 1 CONTENTS 1 Important Safety Rules 2 Tool Specification 2.1 Nomenclature 2.2 Technical Data 3

More information

TECHNICAL DATA. Dry 122a. November 12, 2013

TECHNICAL DATA. Dry 122a. November 12, 2013 Dry 122a 1. PRODUCT DESCRIPTION The Viking is a quick-opening device. When installed with the required external Anti-flood Device, the assembly is designed to increase the operating speed of Viking Model

More information

Unit 24: Applications of Pneumatics and Hydraulics

Unit 24: Applications of Pneumatics and Hydraulics Unit 24: Applications of Pneumatics and Hydraulics Unit code: J/601/1496 QCF level: 4 Credit value: 15 OUTCOME 2 TUTORIAL 1 HYDRAULIC PUMPS The material needed for outcome 2 is very extensive so there

More information

COMPRESSED AIR DRYER

COMPRESSED AIR DRYER COMPRESSED AIR DRYER Model 40211 ASSEMBLY and OPERATING INSTRUCTIONS 3491 Mission Oaks Blvd., Camarillo, CA 93011 Visit our Web site at http://www.harborfreight.com Copyright 2002 by Harbor Freight Tools.

More information

E/P Regulator (DeviceNet TM type) ITV1000/2000/3000/2090-DE* Series

E/P Regulator (DeviceNet TM type) ITV1000/2000/3000/2090-DE* Series Doc. No. ITV2-OM00095-B P R O D U C T N A M E E/P Regulator (DeviceNet TM type) MODEL/ Series/ Product Number ITV1000/2000/3000/2090-DE* Series Install and operate the product only after reading the Operation

More information

Series IDU/IDF. Refrigerated Air Dryer

Series IDU/IDF. Refrigerated Air Dryer Refrigerated ir ryer Series IU/IF The models IF1 to 11 and IU3 to 6 have been revised. For details, refer to catalog no. S30-8. Similar updating for other IF/IU models is scheduled to follow shortly. In

More information

APPLIED PNEUMATICS AND HYDRAULICS H TUTORIAL HYDRAULIC AND PNEUMATIC CYLINDERS. This work covers part of outcome 2 of the standard Edexcel module.

APPLIED PNEUMATICS AND HYDRAULICS H TUTORIAL HYDRAULIC AND PNEUMATIC CYLINDERS. This work covers part of outcome 2 of the standard Edexcel module. APPLIED PNEUMATICS AND HYDRAULICS H TUTORIAL HYDRAULIC AND PNEUMATIC CYLINDERS This work covers part of outcome 2 of the standard Edexcel module. The material needed for outcome 2 is very extensive so

More information

Rexroth Hydraulic Pump A10VO Series User Manual

Rexroth Hydraulic Pump A10VO Series User Manual Rexroth Hydraulic Pump A10VO Series User Manual Rexroth Hydraulic pump A10VO Series User Manual Revised 5/1/2009 Page 1 of 12 Functional Purpose This pump is preferred over a fixed displacement (gear)

More information

Proportional pressure regulators VPPE

Proportional pressure regulators VPPE Proportional pressure regulators VPPE Proportional pressure regulators VPPE Product range overview Function Version Pneumatic connection Proportional pressure regulator Nominal size for pressurisation/

More information

Electro-pneumatic control valves

Electro-pneumatic control valves Electropneumatic control valves 7 Miniature solenoid valves for alternating current Conform to the Low Voltage Directive or mounting on subbase or footprint in accordance with CNOMO recoendation E 066120N

More information

2-Way heavy duty flow control, with pressure compensated, solenoid and load sensing controlled priority flow

2-Way heavy duty flow control, with pressure compensated, solenoid and load sensing controlled priority flow 2-Way heavy duty flow control, with pressure compensated, solenoid and load sensing controlled priority flow RE 18309-64/04.10 1/6 Replaces: RE 00171/02.07 A-VRFC2C-VEI-VS-LS 0M.28.03.80 - Y - Z Description

More information

S GATE KNIFE GATE VALVE WITH PNEUMATIC ACTUATOR

S GATE KNIFE GATE VALVE WITH PNEUMATIC ACTUATOR MAIN FEATURES The pneumatic S GATE knife gate valve is intended for the automatic shut off of pipes of the heavy fluids like slurries and powders. The main fields of application are the water treatment,

More information

Round Housing with Side Ports

Round Housing with Side Ports Power Steering Steering Control Unit (SCU) Parts and Repair Information 5 Series Steering Control Units 001 Square Housing with Side Ports Round Housing with Side Ports T E L RP Round Housing with End

More information

CEILING CASSETTE FAN COIL UNIT

CEILING CASSETTE FAN COIL UNIT CEILING CASSETTE FAN COIL UNIT Operation and Installation Manual MHCFC4W-04, 08, 12, 16 Four way ceiling cassette fan coil unit Please read this manual before using the fan coil unit. Installation and

More information

Electro-Pneumatic Bus Door Control Mechanism

Electro-Pneumatic Bus Door Control Mechanism Electro-Pneumatic Bus Door Control Mechanism Application and Feature 1. Pneumatic Door Mechanism actuates the open/close movements of bus door through two double acting cylinders and two linkages with

More information

Air Catch Sensor. Series ISA. For Workpiece Placement Confirmation

Air Catch Sensor. Series ISA. For Workpiece Placement Confirmation Air Catch Sensor Series For Workpiece Placement Confirmation No-contact sensor for confirming workpiece placement, with a configuration that is less affected by supply pressure change. Easy-to-set-up LED

More information

Control- and feedback head for integrated mounting on Robolux valves Type 2036

Control- and feedback head for integrated mounting on Robolux valves Type 2036 Control- and feedback head for integrated mounting on Robolux valves Type 203 Type 885 Type 88 can be combined with Compact stainless steel design Contactless valve position registration Coloured illuminated

More information

ALMATEC Series CX CX 10 CX 130

ALMATEC Series CX CX 10 CX 130 ALMATEC Series CX CX 10 CX 130 Operating and Installation Instructions ought to be studied before installing the pump The ALMATEC Maschinenbau GmbH is certified as a modern, quality-orientated enterprise

More information

kymanual or Automatic - it s your Choice

kymanual or Automatic - it s your Choice . kymanual or Automatic - it s your Choice ky LKB Automatic or Manual Butterfly Valve Application LKB is a sanitary automatically or manually operated butterfly valve for use in stainless steel pipe systems.

More information

COUNTERBALANCE VALVES

COUNTERBALANCE VALVES COUNTERBALANCE VALVES Introduction They are modulating valves which allow free flow into the actuator and then block the reverse flow until they feel a pilot pressure inversely proportional to the load

More information

Float and Thermostatic Traps Series H, C and X

Float and Thermostatic Traps Series H, C and X Hoffman Specialty Installation & Maintenance Instructions HS-(E) and Thermostatic Traps Series H, C and X Series C & NPT Series C NPT Series X NPT Series C NPT Series H Ratings Maximum Max. Operating NPT

More information

3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve

3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve 3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve Type 6518 Type 6519 Type 6518/6519 can be combined with... Single or block mounting Suitable for outdoor and chemical atmospheres Suitable for

More information

Ball valve C 16 valve ball completely moulded in place, extremely low clearance volume, high k v value

Ball valve C 16 valve ball completely moulded in place, extremely low clearance volume, high k v value Ball valve C valve ball completely moulded in place, extremely low clearance volume, high k v value Advantage maximum safety due to valve ball completely moulded in place - ball and ball seat cannot be

More information

Self Purging Liquid Trap (SPLT ) User s Manual

Self Purging Liquid Trap (SPLT ) User s Manual Self Purging Liquid Trap (SPLT ) User s Manual High pressure liquids and gases are potentially hazardous. Energy stored in these liquids and gases can be released unexpectedly and with extreme force. High

More information

15/40/80CN Series Medium Pressure Filters

15/40/80CN Series Medium Pressure Filters 1/4/8CN Series Medium Pressure Filters Max 32 l/min - 7 bar Global Filtration Technology 1/4/8CN Series TYPICAL APPLICATIONS Compressor Lube Oil Off-line Filter Loops Machine Tools (Automotive Standard)

More information

3/2- and 2/2-way cartridge valve type BVE

3/2- and 2/2-way cartridge valve type BVE 3/2- and 2/2-way cartridge valve type BVE for any flow direction, zero leakage, all ports pressure resistant Flow Q max = 70 lpm Perm. pressure p max = 400 bar Additional valves with same function: ' Type

More information

AIR-AIR PRESSURE MULTIPLIER (BOOSTER)

AIR-AIR PRESSURE MULTIPLIER (BOOSTER) AIR-AIR PRESSURE MULTIPLIER (BOOSTER) The air-air pressure multiplier, or booster, is an automatic device that compresses air to give an outlet pressure that is double the inlet pressure. It is normally

More information

ONE OF THE SMALLEST SNAP-ACTION SWITCHES IN THE WORLD. FEATURES Superminiature type, light-weight snap action switch PC board terminal type (0.

ONE OF THE SMALLEST SNAP-ACTION SWITCHES IN THE WORLD. FEATURES Superminiature type, light-weight snap action switch PC board terminal type (0. ONE OF THE SMALLEST SNAP-ACTION SWITCHES IN THE WORLD SWITCHES FEATURES Superminiature type, light-weight snap action switch PC board terminal type (0.2g) Solder terminal type with mounting holes (0.3g)

More information

SELECTION, APPLICATION AND MAINTENANCE

SELECTION, APPLICATION AND MAINTENANCE DIESEL PROTECTION SYSTEMS D-Series Engine Automatic Overspeed Shut Down Valves (Spindle Types with Air Pressure and Manual Shut Down Options) SELECTION, APPLICATION AND MAINTENANCE Valve Numbers D92-AP

More information

Basic Hydraulics and Pneumatics

Basic Hydraulics and Pneumatics Basic Hydraulics and Pneumatics Module 1: Introduction to Pneumatics PREPARED BY IAT Curriculum Unit March 2011 Institute of Applied Technology, 2011 ATM 1122 Basic Hydraulics and Pneumatics Module 1:

More information

Digital inductive conductivity transmitter

Digital inductive conductivity transmitter Digital inductive conductivity transmitter Optimal solution for conductivity measurements in difficult fluids (polluted, dirty,...) PEEK/PPA version for CIP applications Large range of process connections

More information

LCD Readout Digital Pressure Switch

LCD Readout Digital Pressure Switch LCD Readout Digital Pressure Switch Series ZSE3 (For )/E3 (For Positive Pressure) For General Pneumatics Easy pressure setting with the digital display RoHS Can be integrated with a vacuum unit, Series

More information

Max primary circuit temperature 90ºC Max primary circuit temp. 90ºC Max secondary circuit temperature 45ºC Max secondary circuit temp.

Max primary circuit temperature 90ºC Max primary circuit temp. 90ºC Max secondary circuit temperature 45ºC Max secondary circuit temp. EGLISH 1 Product description exchanger equipped with an electronic control unit and circulation pump for the primary circuit. All Aqua-Mex variants can be ordered with an interior coil of either titanium

More information

Shut-off & Lockout Valves 1/4" to 1-1/2" port size

Shut-off & Lockout Valves 1/4 to 1-1/2 port size Section 16 Shut-off & Lockout Valves 1/4" to 1-1/2" port size Contents T72 Excelon Shut-off & Lockout Valves 1/4", 3/8" Port Sizes....................................ALE-16-2 T73 Excelon Shut-Off & Lockout

More information

MACBlower Model Number: MAC40R MAC60R MAC80R MAC100R. MAC120R MAC150R MAC 200R Serial # www.macblowers.com

MACBlower Model Number: MAC40R MAC60R MAC80R MAC100R. MAC120R MAC150R MAC 200R Serial # www.macblowers.com MACBlower Model Number: MAC40R MAC60R MAC80R MAC100R MAC120R MAC150R MAC 200R Serial # Fuji Clean USA 41-2 Greenwood Road Brunswick, Maine 04011 207-406-2729 www.macblowers.com MACBlowers The Intelligent

More information

300 Series PA Pump and Cooler Assemblies

300 Series PA Pump and Cooler Assemblies Type 300 Series PA Sizes 300 thru 370 (Page 1 of 9) 300 Series PA Pump and Cooler Assemblies Pump and Cooler Assemblies with Air/Oil Heat Exchanger When compact gear drives require assistance to dissipate

More information

Chapter 5: Flow Valves

Chapter 5: Flow Valves Catalogue HY11-300/UK Contents Chapter : Flow Valves Series Description Size Mounting Page Parker Standard DIN / ISO 1/4 3/8 1/2 3/4 1 06 10 16 Throttle valves, manual adjustment MVI -2 NS -4 FS With free

More information

Compact cylinder Double acting single rod type. SSD SSD-L (with switch) Double acting Compressed air 1.0. 1.6-10 to 60 (no freezing) Rc1/8 Rc1/4 Rc3/8

Compact cylinder Double acting single rod type. SSD SSD-L (with switch) Double acting Compressed air 1.0. 1.6-10 to 60 (no freezing) Rc1/8 Rc1/4 Rc3/8 * U S 4 Specifications escriptions Bore size mm Actuation Working fluid ax. working pressure Pa in. working pressure Pa Withstanding pressure Pa Ambient temperature Port size Stroke length Rubber cushioned

More information

Hydraulic Control Solutions

Hydraulic Control Solutions Hydraulic Control Solutions Vexve s Hydrox hydraulic control solutions are suitable for even the most challenging installation sites and conditions. Specifically designed for district heating and district

More information

How To Use A Flowmeter

How To Use A Flowmeter INLINE flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both PNP and NPN) Connection

More information