Air Catch Sensor. Series ISA. For Workpiece Placement Confirmation

Size: px
Start display at page:

Download "Air Catch Sensor. Series ISA. For Workpiece Placement Confirmation"

Transcription

1 Air Catch Sensor Series For Workpiece Placement Confirmation No-contact sensor for confirming workpiece placement, with a configuration that is less affected by supply pressure change. Easy-to-set-up LED level meter Proper set position is steadily and easily set due to the LED level meter and setting dial. Compliant with manifolds of up to stations Compliant with centralized wiring and piping Above set position (Red) Set position (Green) Below set position (Green) Setting dial Free mounting position Stable detection is available at any mounting position due to the pressure sensor. Wide adjustment range Compliant between and μm Stably detects μm clearance The configuration is unlikely to be affected by supply pressure change due to the air pressure bridge circuit and semi-conductor pressure sensor. IP-compliant Dustproof and dripproof type 8

2 Air Catch Sensor Series How to Order Individual wiring/centralized wiring Output specifications NPT open collector output PNP open collector output Stations to Ex. ) NPN output, stations, centralized wiring terminal block BOX (left), with bracket and gauge -L-BG Ex. ) PNP output, individual wiring, with gauge Accessory --G Bracket: --A Gauge: G-- DIN rail: -- to 7 Option Nil DIN rail compliant B With bracket G With gauge DIN rail must be ordered separately. Wiring specifications Nil Individual wiring (Without terminal block BOX) L Centralized wiring (With terminal block BOX, left side) R Centralized wiring (With terminal block BOX, right side) Gauge: G-- Bracket: --A DIN rail: -- to 7 (Hexagonal) qwe r t x ø. Material: SPC (Nickel plated) L Material: Aluminum 7. ø R / Description No. Description Material Each part order comes with two M x 8 glass Stainless steel Stainless steel Stainless steel Brass tapping screws. Cover glass Outer frame Inner frame Round head Phillips screw Socket Part no L 7 8 Applicable model L - R L R L R L R L R L R 8

3 Series Specifications Fluid Operating pressure range Recommended pressure range Detection distance range Repeatability including temperature characteristics Hysteresis Detection nozzle O.D. Display function Power supply voltage Current consumption Switch output Operating temperature range Operating humidity range Noise resistance Withstand voltage Insulation resistance Vibration resistance Impact resistance Lead wire Mass Port size Enclosure Air consumption Supply pressure. MPa. MPa. MPa Dry air (filtered to μm). to. MPa. to. MPa to μm ± μm ( to C (standard C)) μm or less (Detection distance: to μm) ø. standard (Refer to page 8 for data when the nozzle diameter is modified.) Operating indicator light (Lights ON), Deviation level indicator light to VDC ±%, Ripple (p-p) % or less (With power supply polarity protection) ma or less (Output ON, All LEDs ON) NPN open collector: V, 8 ma or less PNP open collector: 8 ma or less to C (No condensation) to 8 % RH (No condensation) Vp-p, Pulse width μs, Rise time ns VAC in / Hz for minute between live parts and case MΩ or more between live parts and case (at VDC by megameter). mm amplitude in to Hz or acceleration of 8 m/s, whichever is smaller for hours in X, Y, Z direction each (De-energized) 8 m/s in X, Y and Z direction, times each (De-energized) Oil-resistant vinyl cabtire code ( cores, ø., m), Cross section:. mm, Insulator O.D.:. mm g (including gauge and -m lead wire) Rc /8 IP (Dustproof and dripproof type) l /min or less l /min or less l /min or less Working Principle How to Set Pressure S S P Sensor P S, S: Fix orifice S: Variable orifice (adjusted by setting dial) S: Detection nozzle Detection port In a bridge circuit as in the figure above, a detection gap is applied to the detection nozzle (S) while the setting dial S is adjusted to balance the pressure applied to the pressure sensor (P = P). The pressure sensor detects the differential pressure generated when the detection nozzle (S) is released. When the work piece comes close to the detection nozzle, the back pressure P increases until it is larger than P (P P). Then the switch output turns on to notify that the pressure is below the detection gap. 8 S S Air catch sensor is adjusted by using the LED level meter and the setting dial. Large clearance BEST POSITION Small clearance LED level meter + Redq Redw Greenq Greenw Red ON: Output OFF Green ON: Output ON Below set position Set position Above set position () For accurate setting, create the proper setting conditions by applying a clearance gauge to the detection nozzle beforehand. () Confirm that pressure is being applied. At this time, if the setting dial is fully closed, all LEDs should be off. () Turning the setting dial in a plus direction (counterclockwise) will cause the LEDs to turn on in order: Red, Red, Green, Green. () When the Green LED level meter comes on, output will be switched on, so please end the setting process at the point when Green comes on. () Apply a clearance gauge to the detection nozzle once more, and confirm that Green has switched on. () Hold the setting dial with a finger, and tighten the lock nut with a wrench. Tighten so that the setting dial will not turn.

4 Air Catch Sensor Series Internal Circuit and Wiring NPN-type open collector DC (+) Brown Centralized wiring type Refer to the below figure for the relation between terminal block wiring in terminal box and switch. Main circuit of switch Black DC ( ) Blue Load Max.8 ma + to VDC L side GND VCC NC R side PNP-type open collector DC (+) Brown Main circuit of switch Max.8 ma Black DC ( ) Blue Mounting Piping Pressure Source + to VDC. Piping equipment In the piping between the switch body and the detection nozzle, do not use equipment or fittings that can possibly cause leakage or serve as resistance. Do not use One-touch fittings in an environment where the air catch sensor is exposed to water or other liquid. Load q w e r t y Specific Product Precautions Read before handling. Refer to front matters 8 and for Safety Instructions and pages 87 to for Pressure Switch Precautions.. If the detection nozzle is exposed to splashes of water or cutting oil, do not allow backflow from the detection nozzle to the switch body. Install the switch body at a position higher than the detection nozzle wherever possible.. Supply air Since the orifice of the air catch sensor is small, prevent foreign matter from entering the equipment. For this purpose, use supply air that is dry and filtered μm or better.. Operating pressure Since the product adopts a semiconductor pressure sensor, keep the operating pressure not larger than. MPa. Operating Environment. When an air catch sensor is contained in a box, provide an air outlet to constantly keep the atmospheric pressure inside the box. Internal pressure rises will hinder normal air discharge and may lead to possible malfunction.. The air catch sensor is IP-compliant, but when there is a possibility of water, oil, etc. from the exhaust port entering the case interior, use an M fitting to connect a tube, and discharge air in a place where water and oil will not enter the interior. When attached with a gauge, there is a danger of materials entering the gauge interior and causing malfunction, so please remove the gauge and use a plug instead. When mounting a gauge to the exterior, please use piping of as short a length as possible. Failure to do so may result in slower response speed. Maintenance. How to change After loosening the four mounting screws (M x 8), pull straight back on the switch body. Pulling back diagonally can result in bending of the connector pin, etc., so take precautions.. When mounting the switch body to the base, push the pin (main body side) straight into the connector (base side), and evenly mount with four mounting screws (M x 8). Be sure not to forget to include seals, etc. (Tightening torque. N m) Switch assembly O-ring Gasket Base Switch assembly part no. (O-ring:, Gasket: enclosed) - For NPN output - For PNP output 87

5 Series Dimensions: Centralized Wiring Type (Terminal Block Box Type) Body With bracket Manifold Deviation level indicator light 7 Terminal block box 7 (.) Rc /8 DIN rail center SUP Deviation level indicator light L L Terminal block box 7 (.) (.) Setting dial x ø. Lead wire electrical entry Applicable O.D.ø. to ø8. Bracket Gauge x M Station 8 x ø. Gauge n Lead wire electrical entry Applicable O.D.ø. to ø8. Bracket. (Max.7.)... Detection port Rc /8 GND VCC Terminal block box wiring diagram. (Max.7.)... Detection port Rc /8 When the bracket has two stations and the terminal block box is on the right side, it attaches to the second switch, while when it is on the left side, it attaches to the first switch. With n stations, it attaches to the first switch and the nth switch. Dimensions Station L L 8 7 Deviation level indicator light. Body 7 Gauge Terminal block box 7 (.) Lead wire electrical entry Applicable O.D ø. to ø8. Rc /8 DIN rail center (.) GND VCC With DIN rail SUP Setting dial Terminal block box wiring diagram Deviation level indicator light. (Max. 7.).. Station Manifold L. Gauge L L Lead wire electrical entry Applicable O.D.ø. to ø8. n Terminal block box Detection port Rc /8 7 (.) Dimensions: With DIN rail Station L L L

6 Air Catch Sensor Series Dimensions: Individual Wiring Type (Lead Wire Type) Body With bracket Manifold Lead wire ( m) Bracket (8) Lead wire ( m) L L Bracket Deviation level indicator light Gauge Rc /8 DIN rail center SUP Deviation level indicator light (.) Setting dial x ø. 8 x ø. Gauge. (Max.78.)... Detection port Rc /8 When the bracket has two stations, it attaches to the first switch. With n stations, it attaches to the first switch and the nth switch.. (Max.78.).. Station. Detection port Rc /8 n Dimensions Station L L Body With DIN rail Manifold Lead wire ( m) L Deviation level indicator light. (8) Rc /8 DIN rail center SUP Deviation level indicator light. Gauge 7 (.) Setting dial Gauge L L. (Max. 78.). Station. Detection port Rc /8 n Dimensions: With DIN rail Station L L L

7 Series Operation guideline: Design data When you design the pneumatic circuit using the air catch sensor, please refer to the data below. The detection distance of the air catch sensor is between and μm. However, please note that stable detection cannot be done when supply pressure or nozzle size are different. Relation between Nozzle Diameter and Detection Distance The data in the following charts are characteristics of hysteresis at the detection distance. In case accuracy is required by the settings, the design should be made so that the hysteresis will stay within the optimum adjustment range not larger than μm. The smaller the hysteresis, the better the sensitivity. In cases where the hysteresis exceeds μm, the air catch sensor should be used to check the presence of the work piece. 7 Detection nozzle: ø. Detection side piping: ø x ø tubing 7 Detection nozzle: ø. Detection side piping: ø x ø tubing 7 Detection nozzle: ø. Detection side piping: ø x ø tubing Supply pressure Supply pressure Hysteresis (μm) Supply pressure.mpa Hysteresis (μm).mpa Hysteresis (μm).mpa Not detectable.mpa.mpa Optimum adjustment range.mpa.mpa Optimum adjustment range.mpa.mpa Optimum adjustment range Detection distance (μm) Detection distance (μm) Detection distance (μm) Ex. ) To detect μm, select a ø. detection nozzle and supply pressure of. MPa. Ex. ) To detect μm, select a ø. detection nozzle. Nozzle Shape Please keep the nozzle shape as illustrated below. Take every caution against chamfer on the detection surface and/or nozzle hole, which could affect the characteristics as illustrated in Figure (). Figure () ø ø. ø Detection surface Chamfer is not allowed. or more or more or more ø or more ø or more ø or more 8

8 Air Catch Sensor Series Response Time Response time changes with detection distance and piping length. It is hardly influenced by the supply pressure and nozzle diameter (ø. to ø.). While both graphs assume a fixed set distance with changes in the detection distance, Fig. shows responses at various set values and Fig. shows responses at various piping lengths. If the detection distance is equal to the set value, the response becomes quicker as the set value becomes smaller or the piping length becomes shorter. Detection nozzle: ø. Operating piping: ø x ø tubing (m) Supply pressure:. MPa Detection nozzle: ø. Operating piping: ø x ø tubing Supply pressure:. MPa Set distance: μm Response time (sec)..... Set value μm μm μm μm Response time (sec) Piping tubing length m 8m m Detection distance (μm) Fig. Detection distance Response time characteristics.. m m Detection distance (μm) Fig. Response time Piping tubing length Supply Pressure Dependence The charts illustrate changes in the detection distance with fluctuations in the supply pressure. Detection side nozzle: ø. Detection side piping: ø x ø tubing Detection side nozzle: ø. Detection side piping: ø x ø tubing Detection side nozzle: ø. Detection side piping: ø x ø tubing Detection distance (μm) Detection distance (μm) Detection distance (μm) Supply pressure (MPa) Supply pressure (MPa) Supply pressure (MPa) 8

9 Air Catch Sensor Series Non-Contact Sensor for Workpiece Placement Confirmation Stable detection of. to. mm clearance Due to the pneumatic bridge circuit and semiconductor pressure sensor, the non-contact type sensor is hardly affected by fluctuations in the supply pressure. Plug connectors (Centralized wiring) Requires less man hours to wire. Easy to add and remove manifold stations. Terminal box Modular construction Requires less man hours to wire. Optimum position is known at a glance. LED level meter Above set position Set position Below set position Red Green Green With regulator + port solenoid valve Easy-to-operate large dial With port solenoid valve Extraneous material W W W Scale provides guidelines for set position. Individual wiring wiring methods Centralized Wiring Minimum operating pressure kpa (-G) Energy consumption can be reduced compared with the conventional models (Conventional models: kpa) Position of supply port: Either right side or left side is available. 7

10 Air Catch Sensor Series How to Order Manifold Without control unit With control unit C V SR SL PR PL I I N Control unit With regulator + port solenoid valve With port solenoid valve Electrical entry and supply port position PL Centralized wiring with supply port on the right Centralized wiring with supply port on the left Individual wiring with supply port on the right Individual wiring with supply port on the left Note) The supply port position is the one when the switch is viewed from the front. Stations station stations stations stations stations stations B C SL B D E Nil C W M Pressure gauge of regulator Note ) Without pressure gauge Note ) A * E MPa single notation. Square embedded Z * pressure gauge psi single notation MPa E MPa single notation. Z * psi single notation MPa G MPa single notation. Round pressure gauge P * MPa-psi double notation MPa G MPa single notation. P * MPa-psi double notation MPa Note ) Due to new Japanese weight and measurement legislation, psi notation type cannot be sold or used in Japan. Note ) The pressure gauge port is Rc /8. * Manufactured upon receipt of order. Throttle/Manual lock of port solenoid valve Without throttle, without manual lock With throttle, without manual lock Without throttle, with manual lock With throttle, with manual lock Throttle Option Nil Without bracket B With bracket With mounting D bracket for DIN rail Note) DIN rail must be ordered separately. (Refer to page 88.) Voltage of port solenoid valve VAC VAC VAC VAC VDC VDC VAC Manual lock Electrical entry of port solenoid valve D : DIN connector D: DIN connector T : Conduit terminal DL: DIN connector (Without connector) TL: Conduit terminal (With indicator light) (With indicator light) 7

11 Air Catch Sensor Series How to Order For single and double notation type and additional stations Air catch sensor Detection distance G H. to. mm. to. mm Ordering Example Without control unit Centralized wiring Terminal box A E G E Piping specifications Nil N F Rc /8 NPT /8 G /8 Manufactured upon receipt of order. Pressure gauge Note ) Without pressure gauge Note ) MPa single notation. Square embedded pressure gauge Z psi single notation MPa E MPa single notation. Z psi single notation MPa G MPa single notation. Round pressure gauge P MPa-psi double notation MPa G MPa single notation. P MPa-psi double notation MPa Note ) Due to new Japanese weight and measurement legislation, psi notation type cannot be sold or used in Japan. Note ) The pressure gauge port is Rc /8. Manufactured upon receipt of order. Centralized wiring air catch sensor -GEP Individual wiring Output specifications Individual wiring air catch sensor -GEN NPN output PNP output Electrical entry Centralized wiring/supply port right Terminal box Individual wiring Centralized wiring Nil L N P Centralized wiring air catch sensor -HEP Straight Right angle Without lead wire Terminal block box Manufactured upon receipt of order... MPa.. Supply port IN IN... MPa. PUL L... MPa. PUL L... MPa. PUL L... MPa. Supply port IN Right Left Right Stations Bracket DIN rail mounting bracket Stations Stations DIN rail mounting bracket INSR-B set ( station manifold part number) -GEP set (Air catch sensor part number) Prefix the part number of the air catch sensor with an asterisk ( ). INPL-D set ( station manifold part number) -GEN set (Air catch sensor part number) Prefix the part number of the air catch sensor with an asterisk ( ). INSR-D set ( stations manifold part number) -HEP sets (Air catch sensor part number) Prefix the part number of the air catch sensor with an asterisk ( ). With control unit Centralized wiring/supply port left port solenoid valve Supply port IN Left Regulator... MPa. Centralized wiring air catch sensor -HEP... MPa.... MPa.... MPa. Terminal box Bracket Individual wiring/supply port right Individual wiring air catch sensor -GE... MPa.... MPa.... MPa. Bracket port solenoid valve Supply port IN Right Stations Stations ICSL-BDLCE set ( stations manifold part number) -HEP sets (Air catch sensor part number) Prefix the part number of the air catch sensor with an asterisk ( ). IVPR-BDLC set ( stations manifold part number) -GE sets (Air catch sensor part number) Prefix the part number of the air catch sensor with an asterisk ( ). 7

12 Series Specifications Model Detection distance Fluid Operating pressure range Recommended detection nozzle Consumption flow rate l /min (ANR) Supply pressure Power supply voltage Current consumption Switch output Hysteresis Note ) Indicator light Environmental resistance kpa kpa kpa Maximum load current Maximum load voltage Residual voltage Output protection Repeatability (Including temperature characteristics) Enclosure Operating temperature range Operating humidity range Withstand voltage Insulation resistance Vibration resistance -G -G -H -H. to. mm. to. mm Dry air (filtered to μm) to kpa ø. or less 8 or less or less NPN open collector: one output PNP open collector: one output. mm or less (Detection distance range. to. mm, supply pressure to kpa) to kpa ø. or less or less or less to VDC ± %, Ripple (p-p) % or less (With power supply polarity protection) ma or less NPN open collector: one output 8 ma VDC (at NPN output). V or less (at 8 ma) Yes PNP open collector: one output. mm or less (Detection distance range. to. mm, supply pressure to kpa). mm or less (Detection distance range. to. mm). mm or less (Detection distance range. to. mm) LED level meter Note ) with red, green (Set value < detection distance: red, Set value = detection distance: green, Set value > detection distance: green + green ) IP: with pressure gauge IP: without pressure gauge Operating: to C, Stored: to 7 C (No condensation or no freezing) Operating/stored: to 8%RH (No condensation) VAC or more in / Hz for minute between live parts and case MΩ or more between live parts and case (at VDC by megameter). mm amplitude in to Hz or acceleration of 8 m/s without control unit and bracket mounted, Others m/s, whichever is smaller for hours in X, Y, Z direction each (De-energized) Impact resistance Without control unit and bracket mounted: 8 m/s, Others: m/s in X, Y and Z direction, times each (De-energized) Port size Nil: Rc /8, N type: NPT /8, F type: G /8 Lead wire (Individual wiring type) cores, oil-resistant cable (ø, m) with M -pin pre-wired connector, Conductor O.D.:. mm, Insulator O.D.:.7 mm Terminal block box (Centralized wiring type) Front wiring (Electrical entry ø) Individual wiring type (body only): g, common wiring type (body only): g, Mass Terminal box: g, lead wire: 78 g, connecting bracket with sealing for additional station: g Standard Compliant with CE marking Note ) Refer to Relation between Nozzle Diameter and Detection Distance (page 78) for hysteresis. Note ) Refer to Setting Procedure (page 8) for LED level meter. Working Principle S S P Sensor S P Detection port S, S: Fix orifice S: Variable orifice (adjusted by setting dial) S: Detection nozzle S In a bridge circuit as in the left figure, a detection gap is applied to the detection nozzle (S) while the setting dial S is adjusted to balance the pressure applied to the pressure sensor (P = P). The pressure sensor detects the differential pressure generated when the detection nozzle (S) is released. When the work piece comes close to the detection nozzle, the back pressure P increases until it is larger than P (P P). Then the switch output turns on to notify that the pressure is below the detection gap. 7

13 Air Catch Sensor Series Internal Circuit and Wiring NPN open collector output Main circuit of switch DC (+) Load DC () MAX 8 ma to VDC Circuit and Wiring for Port Solenoid Valve Without indicator light DC circuit SOL ZNR DC (+) to VDC Without display light AC Circuit Rectifying device SOL ZNR ( ) to VAC PNP open collector output Main circuit of switch DC (+) DC () MAX 8 ma Load to VDC DC () Conduit terminal With indicator light DC circuit DC (+) ZNR SOL to VDC LED DC () Conduit terminal DIN type connector With indicator light AC Circuit Rectifying device SOL ZNR indicator light ( ) ( ) ( ) to VAC DIN type connector With indicator light DC circuit SOL ZNR LED DC (+) DC () to VDC Refer to catalog and instruction manual of Series VCA for wiring. Pay attention to the power supply voltage. Use of incorrect power supply will cause damage to equipment. Wiring Individual wiring : NC : Brown : Blue : Black Brown Blue Black DC (+) NC DC () Centralized wiring Terminal block DC () DC (+) NC. Insert the connector of the lead wire with its key groove at the proper position.. Hold the knurl with fingers and rotate it clockwise. Do not use tools. Lead wire with connector Knurl. Mount the seal conduit on the terminal box. For mounting procedure, refer to the catalog and instruction manual provided by the manufacturer of the seal conduit.. Thread the cable through the seal conduit and arrange wiring according to the polarity of the terminal block illustrated above.. Fasten the seal conduit with a tightening torque not greater than N m. Do not hold the terminal box or the switch.. Connect the colored wires coming from the cable terminal. Refer to the circuit diagram and table above to avoid mistakes. Seal conduit entry (ø) 77

14 Series Relation between Nozzle Diameter and Detection Distance The data in the following charts are characteristics of hysteresis at the detection distance. In case accuracy is required by the settings, the design should be made so that the hysteresis will stay within the optimum adjustment range not larger than. mm. The smaller the hysteresis, the better the sensitivity. In cases where the hysteresis exceeds. mm, the air catch sensor should be used to check the presence of the work piece. -G Detection nozzle: ø. Detection side piping: ø x ø tubing m. Supply pressure. kpa kpa.. kpa.. Optimum adjustment range..... Hysteresis (mm) -H Detection nozzle: ø. Detection side piping: ø x ø tubing m. Supply pressure. kpa.8 Hysteresis (mm) Optimum adjustment range kpa kpa Detection nozzle: ø. Detection side piping: ø x ø tubing m. Supply pressure. kpa.8 Hysteresis (mm) kpa kpa. Optimum adjustment range..... Detection nozzle: ø. Detection side piping: ø x ø tubing m. Supply pressure. kpa.8 kpa.7 Hysteresis (mm) Optimum adjustment range kpa Detection nozzle: ø. Detection side piping: ø x ø tubing m. Supply pressure. kpa kpa.. kpa.. Optimum adjustment range..... Hysteresis (mm) Detection nozzle: ø. Detection side piping: ø x ø tubing m. Supply pressure. kpa.8 kpa.7 Hysteresis (mm) Optimum adjustment range kpa 78

15 Air Catch Sensor Series Response Time Response time changes with detection distance and piping length. It is hardly influenced by the supply pressure and nozzle diameter (ø. to ø.). While all graphs assume a fixed set distance with changes in the detection distance, the upper charts show responses at various set values and the lower charts show responses at various piping lengths. If the detection distance is equal to the set value, the response becomes quicker as the set value becomes bigger or the piping length becomes shorter. -G Detection nozzle: ø. Supply pressure: kpa Detection side piping: ø x ø tubing m. Set value Response time (sec) Detection nozzle: ø. Detection side piping: ø x ø Response time (sec). mm Detection distanceresponse time characteristics... Supply pressure: kpa Set distance:. mm m Piping tubing lengthresponse time Nozzle Shape. mm. mm Piping tubing length. mm m 8 m m m -H Detection nozzle: ø. Supply pressure: kpa Detection side piping: ø x ø tubing m Response time (sec) Detection distanceresponse time characteristics Detection nozzle: ø. Detection side piping: ø x ø Response time (sec). Set value. mm. mm. mm Supply pressure: kpa Set distance:. mm. mm. mm Piping tubing length m Piping tubing lengthresponse time m 8 m m m Please keep the nozzle shape as illustrated below. Take every caution against chamfer on the detection surface and/or nozzle hole, which could affect the characteristics as illustrated in Figure (). ø ø. ø Figure () Detection surface Chamfer is not allowed. or more or more or more ø or more ø or more ø or more 7

16 Series Supply Pressure Dependence The charts illustrate changes in the detection distance with fluctuations in the supply pressure. -G Detection nozzle: ø. Detection side piping: ø x ø tubing m..... mm. mm. mm Supply pressure (kpa) -H Detection nozzle: ø. Detection side piping: ø x ø tubing m mm. mm. mm Supply pressure (kpa) Detection nozzle: ø. Detection side piping: ø x ø tubing m..... mm. mm. mm Supply pressure (kpa) Detection nozzle: ø. Detection side piping: ø x ø tubing m mm. mm. mm Supply pressure (kpa) Detection nozzle: ø. Detection side piping: ø x ø tubing m..... mm. mm. mm Supply pressure (kpa) Detection nozzle: ø. Detection side piping: ø x ø tubing m mm. mm.. mm Supply pressure (kpa) 8

17 Air Catch Sensor Series Setting Procedure The detection distance is set with the LED level meter and setting dial. Keep the setting dial pulled out while in use. If released, it will return to its original position and become unable to rotate.. For accuracy in setting, apply a clearance gauge to the detection nozzle to replicate the set condition in advance.. Confirm that the set pressure is applied. If the setting dial is fully open, the LED level meter appears as.. Pull the setting dial and rotate it in the positive direction. The lights will turn on in the order shown below. Before pulling out Pull out Red Green Rotate in the positive direction. IN Pulled out Handling and setting of port solenoid valve Throttle setting for blowing to prevent water and cutting oil from entering the nozzle. (Clockwise: Close throttle; Counterclockwise: Open throttle) The setting is not applicable to valves without throttle.. Power off the valve.. Rotate the throttle clockwise for adjustment so that the detection nozzle will not suck up water or cutting oil. Rotate clockwise Green. The sensor output comes on when the lights on the LED level meter turn on as. Complete the setting when this condition is observed.. Apply the clearance gauge again to confirm that the lights turn on as. Handling and setting of limit gauge indicator. Removal of cover Hook the finger on the front cover ridge and rotate it in the direction of the OPEN arrow until it stops ( ). Then pull out and remove the cover. OPEN arrow. Setting the installation needle The installation needle should be moved by the fingertip. Set the green installation needles at the maximum and minimum limits of pressure. Example Maximum. MPa Minimum. MPa Throttle Solenoid. Installation of cover After setting the installation needles, locate the OPEN arrow at the top right position and insert the claws on the cover into the grooves on the case (indicated by in the expanded view of A part). Rotate the cover clockwise until it stops. Confirm that the cover is firmly secured.. Power on the valve, then off again. Confirm that the detection nozzle does not suck up water or cutting oil. Note) Do not rotate the throttle more than turns or it will fall out. Expanded view of A part A Finger 8

18 Series Relation between Dial Scale and Detection Distance Test procedure and conditions Dial scales when the detection nozzle is under the following conditions; Supplied pressure: kpa Piping: ø x ø tubing, m in length. Results of measurement Note ) Relation between the detection distance and set dial scales Note ) (Scale numbers) -G -H Detection distance Detection nozzle diameter Detection nozzle diameter Detection distance ø. ø. ø. ø. ø. ø.. mm. mm. mm. mm. mm. to.7. to.. to.. to.. to.. to.. to.8. to.. to.. to 7.. to.7. to..7 to.. to 7.. to.7. mm. mm. mm. mm. mm. to.. to.. to.. to.8. to.. to.8. to.. to.. to 7.. to 7.. to.. to. 7. to to. 8. to.7 Average variation per scale (Detection distance [mm]) -G Detection distance. mm. mm. mm. mm. mm Detection nozzle diameter ø. ø. ø Note ) This data provides reference values as a guide only, this should not be viewed as a guarantee of our products performance. Note ) Set dial scales are as follows; -H Detection distance. mm. mm. mm. mm. mm Detection nozzle diameter ø. ø. ø Scale A scale Between each major scales, it is sub divided into ten smaller settings (for example, between. to..,.,. etc.), settings are possible at. scale. 8

19 Air Catch Sensor Series Dimensions: Centralized Wiring Type When the is on the left, the stations are sequentially numbered from the side of the terminal block box. With bracket L Terminal block box 8 L 8 LED level meter End plate L End plate R 8 Setting dial MPa. MPa. MPa. Pressure gauge DC () DC (+) Terminal block box wiring diagram With DIN rail (Max. ) 7. Terminal block box. Left Right Stations n Seal conduit entry (ø) 8 L L Detection port Rc, NPT, G /8 L 8 Bracket Stations L L L M x 8 (With HW, SW) Rc, NPT, G /8 LED level meter For the bracket attachment position, refer to page 8. End plate L End plate R MPa. MPa. MPa. 8.. Pressure gauge. L L DIN rail mounting bracket L Left Right Stations n Rc, NPT, G /8 DIN rail center DC () DC (+) Terminal block box wiring diagram (Max. ).8 7 Seal conduit entry (ø) Detection port Rc, NPT, G /8 Stations L L L L L

20 Series Dimensions: Individual Wiring Type With bracket LED level meter End plate L 8 L L 8 Lead wire connector End plate R Setting dial MPa. MPa. MPa. Bracket Rc, NPT, G /8.. L Pressure gauge Plug Left Right Stations n (Max. ) Stations L L L M x 8 (With HW, SW) Detection port Rc, NPT, G /8 For the bracket attachment position, refer to page 8. With DIN rail L LED level meter 8 L 8 Lead wire connector End plate L End plate R DIN rail center 8 Rc, NPT, G /8. 8. Pressure gauge. PUL L... MPa. PUL L PUL L MPa. MPa. DIN rail mounting bracket L L L Setting dial Plug Electrical entry dimensions Straight union Right angle Left Right Stations n. The direction of a right angle connector cannot be changed. 8.8 (Max. ).8 7 Detection port Rc, NPT, G /8 Stations L L L L L

21 Air Catch Sensor Series Dimensions: With Control Unit on the left Throttle needle Rc, NPT, G / 8 Rc, NPT, G / MPa... DIN connector. Manual lock 8 7 on the right Conduit terminal With regulator + port solenoid valve DIN connector Conduit terminal With port solenoid valve Conduit terminal 7 8 Conduit terminal DIN connector DIN connector..... MPa Rc, NPT, G / Throttle needle Rc, NPT, G / With regulator + port solenoid valve With port solenoid valve 8

22 Series Bracket Mounting Position With stations, the bracket is mounted on the second sensor from the left. Left Right MPa MPa MPa MPa MPa MPa With n stations, the bracket is mounted on the first and n th sensor from the left. n MPa MPa MPa Addition of Manifold Stations. Disassembly. Loosen the screws and remove the mounting brackets on the front and back side.. Disassemble the switch carefully so that the O-ring on the SUP port will not be detached. End plate removal Slot for removal Existing joint brackets Hook the fingers on the top and bottom removal grooves to pull out the plate. It can be removed by pulling horizontally.. Insertion Recess Existing joint brackets. Assembly Protrusion Joint brackets (--A) The switch for adding stations. Fit seal for additional station (-7-B) to the recess of the of the additional switch.. Fit the protrusion of the additional switch into the existing switch.. Mount joint brackets (--A) at positions. Note) Perform temporary tightening of screws.. Confirm that the recess of the of the existing switch has seal for additional station attached.. Fit the protrusion of the existing switch into the recess of the additional switch.. Mount the existing joint bracket. Note) Perform temporary tightening of screws.. Tighten the joint brackets with the prescribed tightening torque of. N m.. Arrange pneumatic piping and confirm that there is no air leakage from new joints. 8

23 Air Catch Sensor Series Parts List End plate R --B Terminal block box Regulator IN Spacer Y Seal for additional station -7-B Throttle port solenoid valve Spacer Y End plate L --A Seal for additional station -7-B -7-A When air catch sensors are connected or valve is connected to the When a port solenoid when a port solenoid right: valve is connected to the left: Terminal block box --L (Centralized wiring/supply port left) --R (Centralized wiring/supply port right) End plate L --A Switch mounting bracket --A Left Right End plate R --B Joint bracket --A A pair consists set. Lead wire with connector (Individual wiring type) -8-A -8-B Straight, m Right angle, m Bracket --A DIN rail mounting bracket --A With mounting screw pcs. 87

24 Series DIN Rail Pressure Gauge for Air Catch Sensor Regulator Nil N F L Thread type Rc NPT G Option (The shape of pressure gauge) Note ) Nil None E Square embedded pressure gauge (With limit indicator) G Note ) Round pressure gauge (With limit indicator) Note ) The pressure gauge port is /8. The pressure gauge is included in the package (not assembled). Note ) Order individually when. MPa gauge is required. Option specification Nil None N Non-relieving R Flow direction: Right to left Z Note ) Unit representations on the label and pressure gauge are psi and F When specifying more than one option, enter symbols first in numerical, then in alphabetical orders. Note ) Compatible with thread type NPT. Under the New Measurement Law, this type is only sold outside Japan. (The SI unit is used inside Japan.) In all cases, with the exception of NPT, add -X at the end of the order number. Example) AR-E--X Standard Specifications Model Port size Fluid Proof pressure Maximum operating pressure Set pressure range Gauge port size Note ) Relief pressure Ambient and fluid temperature Construction Mass (kg) Pressure gauge. MPa Round Note ) Square embedded Note ) Note ) The type with square embedded pressure gauge does not have connection. Note ) The in the part number of the round pressure gauge indicates the type of connection threads, no symbol for R and N for NPT. Contact SMC for supply of the connection thread type NPT and the pressure gauge of psi unit representation. Note ) With an O-ring ( pc.) and mounting screws ( pcs.). 7. AR Air. MPa. MPa. to. MPa 8 Set pressure +. MPa {at relief flow of. l/min(anr)} to C (No freezing) Relieving type. G-- GC-AS Part no L Square embedded pressure gauge Round pressure gauge GC AS G Maximum Notation Maximum pressure Notation pressure specifications indication specifications indication Nil MPa single notation. MPa Nil MPa single notation. MPa MPa-psi P Note). MPa P psi single notation. MPa double notation 88 AR Port Solenoid Valve Voltage VAC VAC VAC VAC VDC VDC VAC Standard Specifications Valve specifications Coil specifications Valve type Fluid Withstand pressure MPa Body material Seal material Ambient temperature C Fluid temperature C Enclosure Atmosphere Valve leakage cm /min (ANR) Mounting orientation Vibration resistance/impact resistance m/s Note ) Rated voltage Allowable voltage fluctuation Type of coil insulation Power consumption Apparent power DC AC Note ) Hz Hz Individual wiring type IP- IP- IP- IP- IP- IP- Connection thread Nil P D DL D T TL Applicable models R /8 NPT /8 Note) For double notation of MPa and psi, add -X at the end of part number. Example) G-P--X N F Port size Throttle Rc / NPT / G / Electrical entry Centralized wiring type IS- IS- IS- IS- IS- IS- E VCA7A DL S Q DIN connector DIN connector (With light) DIN connector (Without connector) Conduit terminal Conduit terminal (With light) Direct operation poppet Air, Inert gas. Al HNBR to to (No freezing) Dustproof and jetproof (Equivalent to IP) Environment with no corrosive or explosive gas. or less Free / or less / VDC, /// VAC (/ Hz) ±% rated voltage B type VCA:. W VCA: 7. VA CE marked Note ) Since the AC specifications include a rectifying device, there is no difference between the apparent power required for starting and holding. Note ) Vibration resistance: No malfunction resulted in a one-sweep test in a to Hz range in the axial and right angle directions of the main valve and armature, for both energized and de-energized states. Shock resistance: No malfunction resulted in an impact test using a drop impact tester. The test was performed in the axial and right angle directions of the main valve and armature, for both energized and de-energized states. Nil S B K Without throttle and manual lock With throttle With manual lock With manual lock and throttle

25 Series Specific Product Precautions Be sure to read before handling. Refer to front matters 8 and for Safety Instructions and pages 87 to for Pressure Switch Precautions. Air Catch Sensor Series Operating Environment Warning. Do not use in an environment where vibration or impact occurs. Use a bracket in an environment with vibration exceeding m/s.. The enclosure of the switch conforms to IP and that for the solenoid valve to IP. The pressure gauge and the regulator have open constructions. Take proper protection measures in an environment where water splashes, oil or spatters from welding may adhere to the product.. Since steel piping lacking flexibility is easily affected by moment loads or propagation of vibration, employ flexible tubing, etc., to prevent interactions of such factors.. Although CE accredited, this air catch sensor is not equipped with surge protection against lightning. Necessary countermeasures for possible lightning surge should be fitted to system components as required.. Do not operate in locations having an atmosphere of flammable, explosive or corrosive gases, which can result in fire, explosion or corrosion. The air catch sensor does not have an explosion proof rating.. When an air catch sensor is contained in a box, provide an air outlet to constantly keep the atmospheric pressure inside the box. Internal pressure rises will hinder normal air discharge and may lead to possible malfunction.. The air outlet is provided on the setting dial section of the air catch sensor. Do not turn off air supply to the switch if water or cutting oil splashes around the setting dial. Mounting. If the detection nozzle is exposed to splashes of water or cutting oil, do not allow backflow from the detection nozzle to the switch body. Install the switch body at a position higher than the detection nozzle wherever possible. Piping. Piping equipment In the piping between the switch body and the detection nozzle, do not use equipment or fittings that can possibly cause leakage or serve as resistance. Do not use One-touch fittings in an environment where the air catch sensor is exposed to water or other liquid.. Supply air Since the orifice of the air catch sensor is small, prevent foreign matter from entering the equipment. For this purpose, use supply air that is dry and filtered μm or better.. Operating pressure Since the product adopts a semiconductor pressure sensor, keep the operating pressure not larger than. MPa. Port Solenoid Valve Series VCA Precautions on Design Warning. Energized continuously Please consult with SMC if the product is to be energized continuously for long periods of time. Selection. Leakage voltage Take special precautions if a resistor is used in parallel with the switching element or a C-R element (for surge voltage protection) is used for protection of the switching element. The valve may fail to turn off due to leakage current flowing through the resistor or C-R element. Power supply Switching element C OFF R Leakage voltage AC coil % or less rated voltage Warning Pressure Source Leakage voltage Mounting DC coil % or less rated voltage Valve. Do not use the air catch sensor if the leakage amount increases or the equipment does not operate properly. After installation, connect compressed air and electricity and conduct an appropriate functionality inspection to confirm that the air catch sensor is installed properly.. Do not apply external force to the coil. Apply a wrench to the exterior surface of the piping joint at the time of tightening.. Do not use heat insulators, etc. to keep the temperature at the coil assembly. Do not use a tape heater for freeze prevention except on the piping and body. If may cause the coil to burn. 8

26 Series Specific Product Precautions Be sure to read before handling. Refer to front matters 8 and for Safety Instructions and pages 87 to for Pressure Switch Precautions. Port Solenoid Valve Series VCA Regulator Series AR Electric Circuit In case of series VC (B type coil) Conduit terminal, DIN type connector DC circuit AC circuit (+, -) (-, +) Without indicator light Without indicator light Conduit terminal, DIN type connector DC circuit AC circuit Rectifying (+, -) (-, +) ZNR Indicator light With indicator light Warning ZNR SOL. SOL. Maintenance ZNR ZNR Indicator light device With indicator light Rectifying device SOL. SOL.. Low-frequency operation Perform valve switching at least every days to prevent malfunction. Also, conduct a periodic inspection at intervals of approximately months to use the product in its best condition. Warning. The adjustment knob must be handled manually. Use of tools may cause damage to the product.. Check the inlet and outlet pressure indications on the pressure gauge while setting. If the knob is turned to excess, it may cause internal parts to fracture.. Since products for. to. MPa settings come with a pressure gauge for. MPa, do not apply pressure exceeding. MPa. It may cause damage to the pressure gauge. Mounting and Adjustment. Unlock the knob before pressure adjustment and lock it again when the adjustment is over. Incorrect procedure may cause damage to the knob or lead to the outlet pressure fluctuation. Pull the adjustment knob to release the lock. An orange colored line is provided at the bottom of the adjustment handle for visual checking. Push the pressure regulation knob to engage the lock. If it does not lock easily, turn the knob slightly clockwise or counterclockwise until the orange colored line goes out of sight.. When the product is installed, leave a space of mm on the side of the valve guide (opposite to the knob) for maintenance and inspection. Manual Operation Warning How to operate manually Locking type (tool required) To open valve: Rotate to the right by using a flat head screwdriver. It will still hold open even when the driver removed. To close valve: Rotate to the left by to achieve the former closed position. Electrical operations should be undertaken when the valve is closed. Valve closed (vertical slit) Valve open (horizontal slit) 8

27 Series Specific Product Precautions Be sure to read before handling. Refer to front matters 8 and for Safety Instructions and pages 87 to for Pressure Switch Precautions. Port Solenoid Valve Series VCA Disassembly and Assembly Before the product is disassembled, shut off the power and pressure supply and exhaust the residual pressure. Wiring DIN connector (B type only) The internal wiring of the DIN connector is illustrated below. Connect each terminal to the power supply. Disassembly procedure. Remove the top mounting screws.. Remove the solenoid coil, spring and armature assembly.. If there is any foreign matter adhering on the surface, take appropriate measures to clear it off such as an air blow or washing with neutral detergent. Assembly procedure Reverse the above procedure to assemble the product. In case the electrical entry is changed, also change the mounting orientation of the solenoid coil before assembly. Note ) Tighten the mounting screws by each pair of corners on a diagonal line at the proper tightening torque shown below. Mounting screw Spring Solenoid coil Armature assembly O-ring Body Terminal no. DIN terminal : + () + + (-) : (+) - (+) No polarity. A cabtire cable with an O.D. ø to mm is applicable. Tighten each part with an appropriate tightening torque shown below. Connector Bind screw with a flange Tightening torque. to. N m Washer Rubber seal Note) Fitting cable (Cable O.D. ø to mm) Proper Tightening Torque N m VCA7. to. Gasket Small bind screw Tightening torque. to. N m Note) With a cable O.D. ø to mm, hollow the rubber sealing before use. Wiring. Use electrical wires with a conductive sectional area of. to. mm. Make sure that no excessive force is applied to the wires.. Adopt an electrical circuit which will not cause chattering at the contact.. The voltage variation must stay within the % to +% range of the rated voltage. In case importance is attached to response characteristics due to use of a DC power source, keep the variation within the % to +% range. The voltage drop is the value at the lead wire to which the coil is connected. Conduit terminal In case of a conduit terminal, refer to the marks below for wiring. Tighten each part with an appropriate tightening torque shown below. Seal the piping part (G /) securely with a dedicated electric wiring pipe, etc. - Mark Round head combination screw M Tightening torque. to. N m Mark Terminal cover A A G / Tightening torque. to. N m Round head combination screw M tightening torque. to. N m View A-A (Internal connection diagram) Conduit terminal 8

3 Port Solenoid Valve

3 Port Solenoid Valve Port Solenoid Valve Series V00 Rubber Seal Power consumption 0. W (with power saving circuit) VV0 VV00 V00 -V F VS temperature rises: C (with power saving circuit) Sonic conductance Series Standard Large

More information

Inrush Apparent power (VA) Flow Characteristics/Weight. Port size Rc. Valve model VS3115-01 VS3115-02 VS3110-02 VS3110-03 VS3114-00.

Inrush Apparent power (VA) Flow Characteristics/Weight. Port size Rc. Valve model VS3115-01 VS3115-02 VS3110-02 VS3110-03 VS3114-00. Port Direct Operated Solenoid Valve Series VS5/0 Metal Seal Multiple pressure supply is possible with balanced spool sleeve. Any given port can accept high or low pressure supply without affecting the

More information

Precision Regulator. Series IR1000/2000/3000 ARJ AMR ARM ARP IR IRV VEX1 SRH SRP SRF ARX20 VCHR ITV IC PVQ VER VEA VY2 AP100.

Precision Regulator. Series IR1000/2000/3000 ARJ AMR ARM ARP IR IRV VEX1 SRH SRP SRF ARX20 VCHR ITV IC PVQ VER VEA VY2 AP100. Precision Regulator Series // Basic Type Air Operated Type Series Model Regulating pressure range Page Series Series Series Series Series.5 to MPa. to MPa. to.8 MPa /8 55.5 to MPa. to MPa /4 55. to.8 MPa.

More information

Cross-beam scanning system to detect slim objects. 100 mm 3.937 in

Cross-beam scanning system to detect slim objects. 100 mm 3.937 in 891 Object Area Sensor General terms and conditions... F-17 Related Information Glossary of terms... P.1359~ Sensor selection guide...p.831~ General precautions... P.1405 PHOTO PHOTO Conforming to EMC

More information

LCD Readout Digital Pressure Switch

LCD Readout Digital Pressure Switch LCD Readout Digital Pressure Switch Series ZSE3 (For )/E3 (For Positive Pressure) For General Pneumatics Easy pressure setting with the digital display RoHS Can be integrated with a vacuum unit, Series

More information

How To Read A Pipe From A Sensor

How To Read A Pipe From A Sensor Liquid Level Sensor Installation on pipes. Sensing by means electrostatic capacity and is not influenced by the color of the pipe or liquid. Available in 8 to mm dia. and to mm dia. models to enable sensing

More information

2/8.10.01. These vacuum switches are used in measuring ranges between -1 and 0 bar.

2/8.10.01. These vacuum switches are used in measuring ranges between -1 and 0 bar. CATALOGUE > Release 8.5 > Electronic vacuum switches Series SWM Electronic miniature vacuum switches Series SWM These vacuum switches are used in measuring ranges between -1 and 0 bar. Small dimension

More information

Clear Glass Sensor. Ordering Information E3S-CR67/62. Optimum Sensor for Detecting Transparent Glass and Plastic Bottles

Clear Glass Sensor. Ordering Information E3S-CR67/62. Optimum Sensor for Detecting Transparent Glass and Plastic Bottles Clear Glass Sensor Optimum Sensor for Detecting Transparent Glass and Plastic Bottles E3S-CR67/62 Retroreflective Sensor smoothly detects 5-mm gaps. Detects transparent bottles that have a lens effect.

More information

5 Port Pilot Operated Solenoid Valve Rubber Seal. Specifications Fluid Operating pressure range. 2 position single/3 position 2 position double

5 Port Pilot Operated Solenoid Valve Rubber Seal. Specifications Fluid Operating pressure range. 2 position single/3 position 2 position double For details about certified products conforming to international standards, visit us at www.smcworld.com. 5 Port Pilot Operated Solenoid Valve Rubber Seal Series VF3000 Compact and lightweight: 26.4 mm

More information

3-step setting. 2-Color Display High-Precision Digital Pressure Switch. Series ZSE30A(F)/ISE30A. Added vacuum range.

3-step setting. 2-Color Display High-Precision Digital Pressure Switch. Series ZSE30A(F)/ISE30A. Added vacuum range. 2-Color Display High-Precision Digital Pressure Switch Series ZSE3A(F)/ISE3A RoHS Can copy to up to 1 switches simultaneously. The settings of the master sensor can be copied to the slave sensors. Reducing

More information

Ordering Information. Cylindrical Proximity Sensor E2E/E2E2

Ordering Information. Cylindrical Proximity Sensor E2E/E2E2 Cylindrical Sensor E2E/E2E2 A New Series of Easy-to-use and Tough E2E/E2E2 Models Long-size E2E2 Sensor Conforms to CENELEC Ideal for a variety of applications. With a metal connector that can be tightened

More information

5.0 MPa Pilot Operated 2/3 Port Solenoid Valve & Check Valve

5.0 MPa Pilot Operated 2/3 Port Solenoid Valve & Check Valve 5.0 Ma ilot Operated /3 ort Solenoid Valve & Check Valve Series VCH VCH4/4: ort VCH40: 3 ort VCHC40: Check Valve ilot Operated ort Solenoid Valve [Option] Series VCH40 Stable responsiveness Response time

More information

Specifications. Model Flow type Pressure type. Air Maximum operating pressure. 1.0 MPa Ambient and fluid temperature. 3% F.S.

Specifications. Model Flow type Pressure type. Air Maximum operating pressure. 1.0 MPa Ambient and fluid temperature. 3% F.S. Electro-Pneumatic Proportional Valve Series /VEP Electro-pneumatic proportional valve: Flow type () Controls the flow rate steplessly according to current. (It is a / port valve that has an electrical

More information

Direct Operated Regulator for 6.0 MPa (Relieving Type) How to Order. Body size 30 40

Direct Operated Regulator for 6.0 MPa (Relieving Type) How to Order. Body size 30 40 Direct Operated Regulator for (Relieving Type) Series Service life: 0 million cycles Using NSF-H-certified grease on the guide ring (sliding) part. Improved durability under a high environment with a polyurethane

More information

0.35 0.9. 3 Port Solenoid Valve. Series VQZ100/200/300. Compact, High Flow. Power consumption: 0.35 W/0.9 W SYJ VQZ VP VG VP3

0.35 0.9. 3 Port Solenoid Valve. Series VQZ100/200/300. Compact, High Flow. Power consumption: 0.35 W/0.9 W SYJ VQZ VP VG VP3 Port Solenoid Valve 00/00/00 Metal Seal Rubber Seal 0. 0.9 (Standard) (High pressure type, High speed response type) Power consumption: 0. W/0.9 W Compact, High Flow Body ported Base mounted 00 00 00 00

More information

3 Port Solenoid Valve

3 Port Solenoid Valve ubber Seal ort Solenoid Valve Series SYJ00/00/700 [Option] SYJ VQZ V VG Improved pilot valve ilot valve cover is stronger using stainless steel. Mounting thread is also reinforced from size M1.7 to M.

More information

Givare NC-SRS 280 och 880

Givare NC-SRS 280 och 880 Givare NC-SRS 280 och 880 Aratron AB/Nordic Control, 02 03 SRS280SEALED ROTARY SENSOR PERFORMANCE ±2 Resistance ±20% Hysteresis (repeatability) Accuracy Applied voltage maximum Resolution Output smoothness

More information

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points Features SELV Compliant No Detection Passive Injector Gigabit Compatible Full Protection

More information

No. : EX##-OMF0004 OPERATION MANUAL. SI unit EX12#-SMB1

No. : EX##-OMF0004 OPERATION MANUAL. SI unit EX12#-SMB1 No. : EX##-OMF0004 OPERATION MANUAL EX12#-SMB1 Contents 1. Safety instructions ------------------------------------------------------ P3 2. Notes ------------------------------------------------------

More information

INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks

INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks Securitron Magnalock Corp. www.securitron.com ASSA ABLOY, the global leader Tel 800.624.5625 techsupport@securitron.com in door opening solutions INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate

More information

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application 33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application Features Compliant with the IEEE802.3at Standard -40 to +60 C Temperature Range Diagnostic LEDs Full Protection

More information

Single sub-base valve

Single sub-base valve solenoid valves Mini-valves 10 mm Electrical connection... Mounting... Port sizes... Rated temperature... Fluid... Working pressure... Nominal flow... Pneumatic connections Voltage... Power... NC poppet

More information

Sensing method Appearance a Connection o method Sensing distance Model NPN output PNP output Through-beam Pre-wired (see note 3) Connector.

Sensing method Appearance a Connection o method Sensing distance Model NPN output PNP output Through-beam Pre-wired (see note 3) Connector. Photoelectric Sensor with Built-in Amplifier Photoelectric Sensor with built-in amplifier is applicable to a wide variety of lines and ensures a longer sensing distance than any other model. User-friendly

More information

Small U-shaped Micro Photoelectric Sensor. Enables space saving and quick installation!

Small U-shaped Micro Photoelectric Sensor. Enables space saving and quick installation! 4 Small Micro Photoelectric Amplifier Built-in PM-44 SERIES PM-4 SERIES General terms and conditions... F- selection guide... P.44~ Related Information Glossary of terms / General precautions... P.39~

More information

Part number NPN E2EM-X2C1 E2EM-X2C2 PNP E2EM-X2B1 E2EM-X2B2 NPN E2EM-X4C1 E2EM-X4C2 PNP E2EM-X4B1 E2EM-X4B2

Part number NPN E2EM-X2C1 E2EM-X2C2 PNP E2EM-X2B1 E2EM-X2B2 NPN E2EM-X4C1 E2EM-X4C2 PNP E2EM-X4B1 E2EM-X4B2 R Extended Range Inductive Prox Greater Sensing Distance Offers Greater Design Flexibility H Sensing distances approximately 1.5 to 2 times larger than that of any conventional Sensor H Reduces problems

More information

Duct Humidity Transmitter

Duct Humidity Transmitter SDC-H Duct Humidity Transmitter Features Replaceable sensor element Humidity measurement for air ducts Minimum and maximum value memory 0 0V, 0 0mA or 0V, 4 0mA measuring signals selectable with jumpers

More information

Electrically operated valves Series M-05, 3/2-, 5/2- and 5/3-way G1/8 650 and 750 Nl/min (0.661 and 0.762 Cv)

Electrically operated valves Series M-05, 3/2-, 5/2- and 5/3-way G1/8 650 and 750 Nl/min (0.661 and 0.762 Cv) Electrically operated valves Series M-05, 3/2-, 5/2- and 5/3-way G1/8 650 and 750 Nl/min (0.661 and 0.762 Cv) Order code Series and function M-05-310-HN-442 Standard coil HN at ports 2 + 4 HN at ports

More information

STC 3S012-020-A Series Solenoid Valves

STC 3S012-020-A Series Solenoid Valves STC 3S012-020-A Series Solenoid Valves 3S012-020-A Series Solenoid Valve Specifications Valve Model 3S012-1/8-A 3S012-1/4-A 3S020-1/8-A 3S020-1/4-A Port Size (NPT) 1/8 1/4 1/8 1/4 Valve Type Action 3 Way,

More information

Long sensing range. Most suitable for conveyor lines and parking lot applications. 10 m 32.808 ft (Red LED)

Long sensing range. Most suitable for conveyor lines and parking lot applications. 10 m 32.808 ft (Red LED) NX SERIES Compact Multi-voltage Photoelectric Power Supply Built-in Multi-voltage photoelectric sensor usable worldwide Conforming to ow Voltage and EMC Directive Multi-voltage The NX series can operate

More information

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv) Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv) Order code Series and function 1) Plug socket see page 5.042. MN-06-310-HN-442 Standard coil 1) 441 = 12 V DC, 4.2 W 442 = 24 V DC,

More information

Adjustment functions for both span and shift have been incorporated

Adjustment functions for both span and shift have been incorporated SENSORS FOR SERIES LED Type Wafer Alignment Sensor FX-0-F FT-F9 FD-F7 EX-F70/F60 M SH-7 FD-L4 M-DW The use of a safe LED light beam now allows for high precision detection with a resolution of 0!m (.8

More information

PA5. Series. Quick-Connect Cables with Connectors. Simplifies sensor wiring. Wide variety of connectors attached to cables.

PA5. Series. Quick-Connect Cables with Connectors. Simplifies sensor wiring. Wide variety of connectors attached to cables. Quick-Connect Cables with Connectors PA Simplifies sensor wiring. Wide variety of connectors attached to cables. Series No wiring or staking work needed Shorter replacement time in unlikely event of sensor

More information

4 Posiflow Proportional Solenoid Valves

4 Posiflow Proportional Solenoid Valves 4 Posiflow Solenoid Brass or Stainless Steel Bodies 1/4" to 1/2" NPT 2/2 Features Flow rates adjustable between 0% and 100% of rating Flow rate can also be regulated by a range of electrical inputs (sensors,

More information

Capacitive Prox E2K-X

Capacitive Prox E2K-X Capacitive Prox Threaded, Cylindrical Sensor Detects Metallic and Non-metallic Objects Permits non-contact detection of metallic and non-metallic objects such as glass, wood, water, oil and plastic Allows

More information

ISE4. Series ZSE4. Digital Pressure Switch. LCD Readout. (For vacuum) (For positive pressure) For General Pneumatics

ISE4. Series ZSE4. Digital Pressure Switch. LCD Readout. (For vacuum) (For positive pressure) For General Pneumatics Choice of display units Display units can be easily selected and changed, making these switches globaly acceptable. LCD Readout Digital Pressure Switch Series (For vacuum) (For positive pressure) Vacuum

More information

! WARNING. Before using product, read and understand instructions.

! WARNING. Before using product, read and understand instructions. McDonnell & Miller Installation & Maintenance Instructions MM-600G) Series FS8-W General Purpose Liquid Flow Switch OPERATION This control is an independently mounted water flow sensing device that makes

More information

Electro-pneumatic control valves

Electro-pneumatic control valves Electropneumatic control valves 7 Miniature solenoid valves for alternating current Conform to the Low Voltage Directive or mounting on subbase or footprint in accordance with CNOMO recoendation E 066120N

More information

IMPORTANT DOCUMENTATION DO NOT DISCARD!

IMPORTANT DOCUMENTATION DO NOT DISCARD! PART NO.: 6441-263C SERIES GRT 3 JAW PARALLEL GRIPPERS INFORMATION SHEET IMPORTANT DOCUMENTATION DO NOT DISCARD! Use this information sheet to assist with gripper installation and setup. File with maintenance

More information

How To Use A Flowmeter

How To Use A Flowmeter INLINE flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both PNP and NPN) Connection

More information

Description. Dimensions. Features. www.pwb-encoders.com. precision works better

Description. Dimensions. Features. www.pwb-encoders.com. precision works better Description The MEC22 is a high resolution optical hollow shaft encoder that can be fixed quickly and easily on different sizes of motor shafts. The encoder provides two square wave outputs in quadrature

More information

U-shaped Micro Photoelectric Sensor

U-shaped Micro Photoelectric Sensor SERIES U-shaped Micro Photoelectric Extremely small size enables space saving and quick installation! Extremely small Ultra-small type PM- 24(-R) contributes to the miniaturization of your equipment. Even

More information

TS93 EMR T/PT/TDE. Surface applied door closer

TS93 EMR T/PT/TDE. Surface applied door closer TS EMR T/PT/TDE Surface applied door closer Installation instructions: Pull side track mount door closer with smoke detector (EMR T) Push side track mount door closer with smoke detector (EMR PT) Double

More information

Proportional pressure regulators VPPE

Proportional pressure regulators VPPE Proportional pressure regulators VPPE Proportional pressure regulators VPPE Product range overview Function Version Pneumatic connection Proportional pressure regulator Nominal size for pressurisation/

More information

System 8. ü www.nassmagnet.com ( +49 511 6746-0. System 8

System 8. ü www.nassmagnet.com ( +49 511 6746-0. System 8 System 8 ü www.nassmagnet.com ( +9 11 7-0 System 8 The name System 8 stands for a modular system of solenoid coils, armature systems, solenoid operators and solenoid valves. The diameter of the armatures

More information

Standard Specifications Model. How to Order. Mist spray unit. Recommended Equipment. Mixing valve

Standard Specifications Model. How to Order. Mist spray unit. Recommended Equipment. Mixing valve Mist Spray Unit Series MU/ Intermittent spray to cutting and press gear chains, etc. Standard Specifications MU MU Inlet air Oil tank set range. MPa. to. MPa Oil tank capacity (cm ) Total capacity: Effective

More information

3/2-way Solenoid Valve, direct-acting, NC or NO

3/2-way Solenoid Valve, direct-acting, NC or NO 3/2-way Solenoid Valve, direct-acting, NC or NO Electrical connection cable plug, Form A With or without manual override as standard Threaded port and sub-base s Impulse optional Type 6014 can be combined

More information

Series 30000 Hose Reels

Series 30000 Hose Reels Operating Instructions and Parts List for Series 30000 Hose Reels - MANUAL DRIVEN - - POWER DRIVEN - SAFETY PRECAUTIONS Personal injury and/or equipment damage may result if proper safety precautions are

More information

http://waterheatertimer.org/troubleshoot-rheem-tankless-water-heater.html

http://waterheatertimer.org/troubleshoot-rheem-tankless-water-heater.html http://waterheatertimer.org/troubleshoot-rheem-tankless-water-heater.html TECHNICAL SERVICE DEPARTMENT Removal, Cleaning, & Reinstallation of the Burner Assembly For models 74 & GT199 Required tools -

More information

Liquid Leakage Sensor Amplifier

Liquid Leakage Sensor Amplifier 9 Liquid Leakage Sensor Amplifier Space-saving Sensor Amplifier reliably detects a wide variety of liquids ranging from water to chemical liquids with low conductivity 1 Detects leakage of liquid such

More information

Model 43AP Pneumatic Controller, Style B

Model 43AP Pneumatic Controller, Style B Instruction MI 011-476 January 1980 Model 43AP Pneumatic Controller, Style B Installation and Operation Model 43AP Controller continuously detects the difference between a process measurement and its set

More information

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version) TECHNICAL DATASHEET #TD1102AX CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version) Part Number: Connector Amplifier CAPV-H-4-20MA-x complete with cable CAPV-4C-yM Where: x = current output

More information

IOM SERIES 820-E/P Electro-Pneumatic Positioner

IOM SERIES 820-E/P Electro-Pneumatic Positioner FLUID CONTROL DIVISION Parker Hannifin Corporation 95 Edgewood Avenue New Britain, CT 06051 Telephone (860) 827-2300 IOM SERIES 820-E/P Electro-Pneumatic Positioner INSTALLATION, OPERATING & MAINTENANCE

More information

ENGINE FUEL FUEL FILTER... FUEL HEATER... INJECTOR... SUPPLY PUMP... COMMON RAIL... FUEL PRESSURE LIMITTER...

ENGINE FUEL FUEL FILTER... FUEL HEATER... INJECTOR... SUPPLY PUMP... COMMON RAIL... FUEL PRESSURE LIMITTER... FUEL FILTER............................ FUEL HEATER.......................... INJECTOR.............................. SUPPLY PUMP.......................... COMMON RAIL.......................... FUEL PRESSURE

More information

Valve systems Base plates, according to standard ISO 5599-1. Brochure

Valve systems Base plates, according to standard ISO 5599-1. Brochure ISO 5599-1 Brochure 2 ISO 5599-1 Single subbase Single subbase, thread connections on the side standard: ISO 5599-1 Frame size: ISO 1 - ISO 4 compressed air connection output: G 1/4 - G 1 Reversed pressure

More information

Cable Plug acc. to DIN EN 175301-803, Form A

Cable Plug acc. to DIN EN 175301-803, Form A Cable Plug acc. to DIN EN 175301-803, Form A Complete program Contact form 18 mm Also available with LED indicator Optional 4-pin version for pressure switch or impulse valves respectively Versions with

More information

Pressure transmitter For general industrial applications Model A-10

Pressure transmitter For general industrial applications Model A-10 Electronic pressure measurement Pressure transmitter For general industrial applications Model A-10 WIKA data sheet PE 81.60 for further approvals see page 9 Applications Machine building Shipbuilding

More information

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply) transmitter (2 wire) / switch for continuous or On/Off Control Indication, monitoring, transmitting and continuous or On/Off control in one device Output signal 4...20 ma, 2-wire for continuous control

More information

3. SEISCO PARTS & SERVICE REMOVAL AND REPAIR GUIDE

3. SEISCO PARTS & SERVICE REMOVAL AND REPAIR GUIDE 4 3. SEISCO PARTS & SERVICE REMOVAL AND REPAIR GUIDE A. Changing the Control Board B. Replacing a Heating Element C. Thermistor Replacement D. High Limit Switch Replacement E. Level Detector Replacement

More information

HG600/HG800. Hydro-Power Unit. Installation and Operation Guide

HG600/HG800. Hydro-Power Unit. Installation and Operation Guide HG600/HG800 Hydro-Power Unit Installation and Operation Guide Copyright 04 HydroSpin, All rights reserved. The data contained in this document is proprietary to HydroSpin. It is disclosed to the receiving

More information

Arecont Vision H.264 Color or Day/Night SurroundVideo Series Installation Manual

Arecont Vision H.264 Color or Day/Night SurroundVideo Series Installation Manual 0 P a g e H.264 Color or Day/Night SurroundVideo Installation Manual Inside the box: A. Arecont Vision SurroundVideo camera B. Mounting template C. RJ45 female to female coupler D. Hex key E. Security

More information

Specifications H8CA-S H8CA-S RATINGS. Approved by the following standards CHARACTERISTICS

Specifications H8CA-S H8CA-S RATINGS. Approved by the following standards CHARACTERISTICS Solid-State Counter/Timer 1/16 DIN, Easy-to-Operate Combination Counter and Timer Operation selectable as preset counter or timer 6-digit LCD Present Value: 8 mm (.32 in) Set Value: 4 mm (.16 in) Nonsignificant

More information

Powers Controls TH 192 S Single Temperature Room Thermostat

Powers Controls TH 192 S Single Temperature Room Thermostat Technical Instructions Document No. 155-065P25 TH 192-1 Powers Controls TH 192 S Single Temperature Room Thermostat 50 60 70 80 TH0355R1 70 80 POWERS Description The TH 192 S thermostats are proportional

More information

Assisted lift operated 2/2-way solenoid valves Type EV250B

Assisted lift operated 2/2-way solenoid valves Type EV250B MAKING MODERN LIVING POSSIBLE Data sheet Assisted lift operated 2/2-way solenoid valves Type EV250B EV250B with assisted lift can operate from zero and up to 10 bar differential pressure. This 2/2-way

More information

ONE OF THE SMALLEST SNAP-ACTION SWITCHES IN THE WORLD. FEATURES Superminiature type, light-weight snap action switch PC board terminal type (0.

ONE OF THE SMALLEST SNAP-ACTION SWITCHES IN THE WORLD. FEATURES Superminiature type, light-weight snap action switch PC board terminal type (0. ONE OF THE SMALLEST SNAP-ACTION SWITCHES IN THE WORLD SWITCHES FEATURES Superminiature type, light-weight snap action switch PC board terminal type (0.2g) Solder terminal type with mounting holes (0.3g)

More information

TQ SMD RELAYS TQ SMD LOW-PROFILE SURFACE-MOUNT RELAY FEATURES SPECIFICATIONS

TQ SMD RELAYS TQ SMD LOW-PROFILE SURFACE-MOUNT RELAY FEATURES SPECIFICATIONS LOW-PROFILE SURFACE-MOUNT RELAY RELAYS.55 5.6. FEATURES Low-profile: 6 mm.36 inch (Tape height: max. 6.5 mm.56 inch) Tape and reel package is available as standard packing style Surge withstand between

More information

Absolute Rotary Encoder E6CP

Absolute Rotary Encoder E6CP Absolute Rotary Encoder Absolute Rotary Encoders with Gray Code Output Gray code output decreases output errors Lightweight plastic housing Used with Omron s H8PS Cam Positioner, this encoder detects the

More information

Powers Controls TH 192 HC Heating/Cooling Room Thermostat

Powers Controls TH 192 HC Heating/Cooling Room Thermostat Powers Controls TH 192 HC Heating/Cooling Room Thermostat Technical Instructions Document No. 155-066P25 TH 192-2 50 60 70 80 70 TH0356R1 60 80 POWERS Description The TH 192 HC thermostats are proportional

More information

E2EL Ø 6,5 M8 / Plug M8 M8 / Plug M12 E2EL

E2EL Ø 6,5 M8 / Plug M8 M8 / Plug M12 E2EL High Frequency Inductive Proximity Sensor Increased response frequency for high speed applications Max 5 khz, switching frequency M8 or dia 6.5 mm housing Brass or stainless steel housing Ordering Information

More information

Color Mark Sensor with Red or Green LED E3S-VS

Color Mark Sensor with Red or Green LED E3S-VS Color Mark Sensor with Red or Green LED Rugged IP67 Color Mark Sensor 1 ms response time Detects a wide variety of color marks PNP or NPN output ls Light-on/ Dark-on operation, wire selectable Vertical

More information

STC 2P050 Series Solenoid Valves NSF Compliant Materials, 2 Way, Direct Acting

STC 2P050 Series Solenoid Valves NSF Compliant Materials, 2 Way, Direct Acting STC 2P050 Series Solenoid Valves NSF Compliant Materials, 2 Way, Direct Acting Female NPT Thread 3/8 OD Tube 3/8 Push-In Fitting 2P050 Series Solenoid Valve Specifications Valve Model 2P050-1/4 2P050-3/8

More information

Water Separator. Main Line Filter. Mist Separator. Micro Mist Separator 150C 250C 350C 450C AMG 550C 2C 4C 8C 11C AFF 22C 37B 75B 150C 250C 350C 450C

Water Separator. Main Line Filter. Mist Separator. Micro Mist Separator 150C 250C 350C 450C AMG 550C 2C 4C 8C 11C AFF 22C 37B 75B 150C 250C 350C 450C Water droplet removal Water Separator Water droplet separation rate: % Model Flow capacity l/min (ANR) Max. flow capacity at 0.7 MPa inlet pressure 300 750 1,500 AMG 2,0 AMG to AMG/ Large dust particle

More information

EE-SX91. Meeting Customer Needs with Compact Sensors that Mount with M3 Screws

EE-SX91. Meeting Customer Needs with Compact Sensors that Mount with M3 Screws Compact Pre-wired Photomicrosensor with Built-in Amplifier (Non-modulated) CSM DS_E_7_2 Meeting Customer Needs with Compact Sensors that Mount with M Screws Both light-on and dark-on outputs provided.

More information

Series 510 Submersible Level Transmitters

Series 510 Submersible Level Transmitters Series 510 Submersible Level Transmitters The Series 510 Submersible Level Transmitters are solid state instruments designed for direct submergence into many types of liquid for quick, accurate and reliable

More information

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2... Magnetic and Hydraulic-Magnetic Circuit Breaker 840-G2... Description Single, two and three pole magnetic circuit breakers with trip-free mechanism and push/pull on/off manual actuation. A choice of fast

More information

VC Series Zone Valves BALANCED 2-WAY AND 3-WAY HYDRONIC VALVES

VC Series Zone Valves BALANCED 2-WAY AND 3-WAY HYDRONIC VALVES VC Series Zone Valves BALANCED 2-WAY AND 3-WAY HYDRONIC VALVES PRODUCT DATA Design VC Series zone valves consist of: 2-way or 3-way valve housing available with various connection ends Spindle and cartridge

More information

EE-SPY801/802. Photomicrosensors for detecting wafer-carrier mounting. Wafer-carrier Mounting Photomicrosensors. Ordering Information.

EE-SPY801/802. Photomicrosensors for detecting wafer-carrier mounting. Wafer-carrier Mounting Photomicrosensors. Ordering Information. Wafer-carrier Mounting Photomicrosensors EE-SPY1/ CSM_EE-SPY1 DS_E_3_ Photomicrosensors for detecting wafer-carrier mounting. The mounting position is set with a pedestal. The contact surface with the

More information

VSO MAX HP High Flow Proportional Valve

VSO MAX HP High Flow Proportional Valve VSO MAX HP High Flow Proportional Valve Typical Applications Ventilators Insufflators Anesthesia Delivery & Monitors Pressure & Flow Control Mass Flow Control Product Specifications Physical Properties

More information

CAUTION OPC-LM1-IL. Option Card for Encoder of Line Driver Output. Instruction Manual

CAUTION OPC-LM1-IL. Option Card for Encoder of Line Driver Output. Instruction Manual Instruction Manual OPC-LM1-IL Option Card for Encoder of Line Driver Output CAUTION Deliver this instruction manual without fail to those who actually operate the equipment. Read this operation manual

More information

Instruction Manual. ThinkTop Basic Digital 10-30 VDC PNP/NPN ESE00225EN1 2006-11

Instruction Manual. ThinkTop Basic Digital 10-30 VDC PNP/NPN ESE00225EN1 2006-11 Instruction Manual ThinkTop Basic Digital 10-30 VDC PNP/NPN ESE00225EN1 2006-11 Declaration of Conformity The designating company Alfa Laval Company Name Albuen 31, DK-6000 Kolding, Denmark Address +45

More information

Material: Weight: Bearing Life: Shaft Speed: Starting Torque: Mass Moment of Inertia: Shaft Loads:

Material: Weight: Bearing Life: Shaft Speed: Starting Torque: Mass Moment of Inertia: Shaft Loads: Automation / Mini Type SCH32F Hollow Shaft Encoder - Ø 32 mm Hollow Bore: Ø 6 mm to Ø 3/8 inch Resolution up to 5000 ppr IP 65 (IP 50 for IDC connector option) Electrical Specifications Code: Resolution:

More information

D2QW D2QW-@@@@@- @ - @ 1 2 3 4 5 6 7. Sealed long stroke slide-contact switch for reliable ON/OFF action even in severe environmental conditions.

D2QW D2QW-@@@@@- @ - @ 1 2 3 4 5 6 7. Sealed long stroke slide-contact switch for reliable ON/OFF action even in severe environmental conditions. Sealed long stroke slide-contact switch for reliable ON/OFF action even in severe environmental conditions. Extra-long stroke even without levers. (:.7 mm) Clip contacts with highly reliable slide contact

More information

Part I - Installation

Part I - Installation 400 Series Pressure and Differential Pressure Switches Types: H400, H402, H403, H400K, H402K, J400, J402, J403, J400K, J402K UNITED ELECTRIC CONTROLS Installation and Maintenance Instructions Please read

More information

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS PLEASE READ COMPLETE INSTRUCTIONS BEFORE YOU BEGIN LEAVE INSTALLATION INSTRUCTIONS AND USER'S GUIDE WITH OWNER ALL ELECTRIC WIRING AND PLUMBING MUST BE DONE

More information

Elektromotoren und Gerätebau Barleben GmbH

Elektromotoren und Gerätebau Barleben GmbH Elektromotoren und Gerätebau Barleben GmbH OPERATING INSTRUCTIONS Transformer Protection Relay NM Series (Buchholz principle) Elektromotoren und Gerätebau Barleben GmbH Table of contents Page 1. Safety

More information

TraceTek TTDM Series Leak Detection and Location Modules Replacement Parts Installation Instructions

TraceTek TTDM Series Leak Detection and Location Modules Replacement Parts Installation Instructions TraceTek TTDM Series Leak Detection and Location Modules Replacement Parts Installation Instructions TRACETEK TraceTek TTDM Replacement Parts General Information These instructions detail the steps to

More information

Unit 24: Applications of Pneumatics and Hydraulics

Unit 24: Applications of Pneumatics and Hydraulics Unit 24: Applications of Pneumatics and Hydraulics Unit code: J/601/1496 QCF level: 4 Credit value: 15 OUTCOME 2 TUTORIAL 4 DIRECTIONAL CONTROL VALVES The material needed for outcome 2 is very extensive

More information

MOUNTING AND OPERATING INSTRUCTIONS

MOUNTING AND OPERATING INSTRUCTIONS MOUNTING AND OPERATING INSTRUCTIONS CF 51/55 1. Delivery CF 51/55-1 calculator with battery (optionally with mains power supply) - 1 wall mounting bracket - package with material for sealing, screws, wall

More information

Solid-State Timer H3G

Solid-State Timer H3G ASH & ALAIN INDIA PVT LTD S-100, F.I.E.E., Okhla Industrial Area, Phase-ii, New Delhi-11000(India) Tel : 011-43797575 Fax : 011-43797574 E-mail : sales@ashalain.com Solid-State Timer Low-Cost, Plug-In

More information

Sensors. Sensors. All Cylinders. Specifications. Features: Features Type REED HALL EFFECT NPN or PNP. Ø8mm - 125mm

Sensors. Sensors. All Cylinders. Specifications. Features: Features Type REED HALL EFFECT NPN or PNP. Ø8mm - 125mm Specifications Features Type REED HALL EFFECT NPN or PNP Applicable Series Configurations Construction Materials Body Mounting Bracket Cable Characteristics Operating Temperature Accuracy All Cylinders

More information

Signaling Lights. LH Series Surface Mount Indicators. Part Numbers. Jumbo Dome (one color) Jumbo Dome (two color)

Signaling Lights. LH Series Surface Mount Indicators. Part Numbers. Jumbo Dome (one color) Jumbo Dome (two color) Innovative indicators in a slim & stylish design. uces installation space. LH Series Surface Mount Indicators Key features of the LH series include: Direct mounting on surfaces such as panels, aluminum

More information

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description Photoelectrics, Background Suppression reflective with IR light Main features Description The PD30ET... stainless steel sensors are built with high-quality materials and designed for harsh environments.

More information

36G22, 36G23, 36G24 & 36G52 36J22, 36J23, 36J24 & 36J52 DSI and HSI Single Stage Combination Gas Valve

36G22, 36G23, 36G24 & 36G52 36J22, 36J23, 36J24 & 36J52 DSI and HSI Single Stage Combination Gas Valve Operator: Save these instructions for future use! FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE PERSONAL INJURY AND/OR PROPERTY DAMAGE. DESCRIPTION

More information

E3Z. Ordering Information. Photoelectric Sensor with Built-in Amplifier. Compact Sensor Offers Long Sensing Distance and Superior Noise-Immunity

E3Z. Ordering Information. Photoelectric Sensor with Built-in Amplifier. Compact Sensor Offers Long Sensing Distance and Superior Noise-Immunity Photoelectric Sensor with Built-in Amplifier Compact Sensor Offers Long Sensing Distance and Superior Noise-Immunity H Photo-IC provides long sensing distance: 15 m for through-beam, 4 m for retroreflective,

More information

E8F2. Pressure Sensor with Easy-to-Read LED Display. Digital Pressure Sensor. Ordering Information. Sensors (Refer to Dimensions on page 7.

E8F2. Pressure Sensor with Easy-to-Read LED Display. Digital Pressure Sensor. Ordering Information. Sensors (Refer to Dimensions on page 7. Digital Sensor CSM DS_E_4_3 Sensor with Easy-to-Read LED Display status can be checked at a glance from the digital display and bar display. Measurement pressure prevents incorrect outputs due to momentary

More information

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics 3/2-, 5/2-5/3-way Solenoid Valves for process pneumatics Type 6518 stard High flow-rate capacity Reduced power consumption Single or manifold mounting stard Type 6518/6519 can be combined with... Stard-,

More information

SENSORS. Miniature Sensors - S3Z. Advanced line of miniature Asian style of photoelectric sensors. 40-300 mm background suppression

SENSORS. Miniature Sensors - S3Z. Advanced line of miniature Asian style of photoelectric sensors. 40-300 mm background suppression Advanced line of miniature Asian style of photoelectric sensors 4-3 background suppression.7 m proximity, 15 with narrow beam 4 m polarized retroreflective 3 m LASER through beam Standard 3-wire output

More information

Series P215PR/RM Direct- and Remote-Mount Pressure-Actuated Condenser Fan Speed Controllers for Single-Phase Motors

Series P215PR/RM Direct- and Remote-Mount Pressure-Actuated Condenser Fan Speed Controllers for Single-Phase Motors European Refrigeration Controls Catalogue Catalogue Section 4 Product Bulletin P215PR/RM Issue 01/03/2013 Series P215PR/RM Direct- and Remote-Mount Pressure-Actuated Condenser Fan Speed Controllers for

More information

Proximity Switches RS (Reed Switch)

Proximity Switches RS (Reed Switch) Proximity Switches RS (Reed Switch) General Pneumatic systems can often be combined with electric control circuits. The position of the piston in the cylinder can then be sensed by means of a proximity

More information

E2FM. Inductive Proximity Sensor in full metal housing. Application. Continuous Impact Test. Brush Test

E2FM. Inductive Proximity Sensor in full metal housing. Application. Continuous Impact Test. Brush Test Inductive Proximity Sensor in full metal housing Full body stainless steel housing for highest mechanical protection Low frequency modulation for metal chip immunity Flame retardant cable for high protection

More information

I nstallation. M100Q Series Proportional Actuator with R81Q Controller Board for Thermistor Sensor Applications. Tools Needed.

I nstallation. M100Q Series Proportional Actuator with R81Q Controller Board for Thermistor Sensor Applications. Tools Needed. FANs 268.1, 1628.3 Installation Bulletin M100Q Issue Date 1099 M100Q Series Proportional Actuator with R81Q Controller Board for Thermistor Sensor Applications I nstallation Parts Included M110QGA-1 and

More information