Precision Regulator. Series IR1000/2000/3000 ARJ AMR ARM ARP IR IRV VEX1 SRH SRP SRF ARX20 VCHR ITV IC PVQ VER VEA VY2 AP100.

Save this PDF as:
 WORD  PNG  TXT  JPG

Size: px
Start display at page:

Download "Precision Regulator. Series IR1000/2000/3000 ARJ AMR ARM ARP IR IRV VEX1 SRH SRP SRF ARX20 VCHR ITV IC PVQ VER VEA VY2 AP100."

Transcription

1 Precision Regulator Series // Basic Type Air Operated Type Series Model Regulating pressure range Page Series Series Series Series Series.5 to MPa. to MPa. to.8 MPa / to MPa. to MPa /4 55. to.8 MPa. to MPa. to MPa /4, /8, / 55. to.8 MPa. to.8 MPa /4 55. to.8 MPa /4, /8, / 55 AR45 to 95 V VEX ARX VY AP 549

2 Precision Regulator Series // and pressure gauge can be mounted from directions Mounting is possible on either the front or the back. Expanded regulating pressure range The maximum set pressure has been expanded from the conventional MPa to.8 MPa. Compact and lightweight width 5 mm mass 4 g width 5 mm mass g width 66 mm mass 64 g Manifolding is possible 8 stations at the maximum Made to order specifications (Except Series, ) OUT OUT OUT OUT OUT 55

3 Compatible with new modular connection brackets (-X) Can be combined with AF (Air filter) and AFM (Mist separator). Mount the standard type with a conventional connection bracket. Relief flow characteristics Possible to relieve (exhaust) air ranged 5 to 4 l/min (ANR) Back pressure: MPa Relief flow (l/min (ANR)) Series Variations Specifications Maximum set pressure. Model Basic type Air operated type MPa MPa.8 MPa Rc /8 Rc /4 Rc /8 Rc / Attachments such as a pressure switch can be mounted as accessories Applicable modular size : type : type : 4 type 5 4 Symbol T -L -X -X465 M 4 Relief flow (l/min (ANR)) Made to Order Specifications For details, refer to page 56. Back pressure: MPa. Specifications/Content Clean Series Copper-free and fluorine-free Ozone resistant For high temperature For low temperature Non-grease specifications With digital pressure switch (ISE) Manifold (Except Series, ) AR45 to 95 V VEX ARX VY AP 55

4 Series // Application Example Constant fluid pressure TANK Balance and drive Accurate balance pressure setting Since there is a large effective area for supply and exhaust pressure, setting can be done uickly. Limits pressure fluctuation when driving a cylinder, maintaining excellent static and dynamic balance. Accurate pressure setting Sensitivity within % F.S. (Full Span) Tension control Contact pressure control Winding roller Drive roller Low friction cylinder Adapts to the cylinder's piston displacement, maintaining a constant pressure. Multistage control of pressing force for workpiece (Wrapping machine) Leak test circuit Measured object Low friction cylinder 55

5 Precision Regulator RoHS Series // Basic type JIS Symbol Air operated type Standard Specifications Model Max. supply pressure Min. supply pressure () Regulating pressure range Input signal pressure Sensitivity Repeatability Linearity () Air consumption (4) (At supply pressure of. MPa) () Pressure gauge port :.5 to MPa :. to MPa :. to.8 MPa Rc /8 Set pressure +.5 MPa Basic type :.5 to MPa :. to MPa :. to.8 MPa Rc /4 Max.. MPa Set pressure +. MPa :. to MPa :. to MPa :. to.8 MPa Within % of full span Within ±% of full span 4.4 l/min (ANR) or less 4.4 l/min (ANR) or less.5 l/min (ANR) or less 4.4 l/min (ANR) or less Rc /4, /8, / Rc /8 ( locations) Ambient and fluid temperature 5 to 6 C (No freezing) Mass (kg) 4 5 Note ) With the condition of no flow on the output side. Together with the set pressure, be sure to maintain a minimum differntial pressure of.5 MPa for models and, and. MPa for model. Note ) Applicable only to air operated types and. The basic type is excepted. Note ) Indicates the linearity of the output pressure with respect to the input signal pressure. Note 4) Air is normally being discharged to the atmosphere from a bleed hole or an exhaust port. Body size Precision regulator Type of setting Basic type (Handle) Air operated type (Series / only) Regulating pressure range For series /.5 to MPa. to MPa. to.8 MPa Note) Air operated type is model only. For series. to MPa. to MPa. to.8 MPa Note) Air operated type is model only. How to Order Symbol size 4 Thread type Nil Rc N NPT F G Option /8 /4 /8 / Application Air operated type Set pressure +.5 MPa. to.8 MPa. to.8 MPa Rc /4 Within ±% of full span R Set pressure +. MPa. to.8 MPa. to.8 MPa.5 l/min (ANR) or less Rc /4, /8, / Suffix Nil For high temp. enviroments ( 5 to C) T (Max. 8 C with pressure gauge.) L For low temp. enviroments ( to 6 C) Suffix Nil Accessory Nil B G None With bracket With pressure gauge Note) Pressure gauge,, Name plate, Mounting on the opposite side Note) The standard mounting position of the pressure gauge is on the front, when viewing the regulator with the SUP side to the left and OUT side to the right. Pressure gauge is included, (but not assembled). Made to Order Specifications (Refer to page 56) Symbol Specifications/Content X Non-grease specifications X Compatible with modular connection brackets(refer to page 554) X465 With digital pressure switch (ISEA) Add prefix (-) for the clean room specification. Add prefix (-) for the copper-free and fluorine-free specification. Add prefix (8-) for the ozone-resistant specification. 4 Manifold specification is available for and. (Except and ) 55 AR45 to 95 V VEX ARX VY AP

6 OUT OUT G EXH OUT G G Series // Series Series Series Specification Combinations Standard specifications Accessory Option Specifications : Standard specifications : Combination possible : Combination not possible Applicable model Set pressure Max. MPa Set pressure Max. MPa Set pressure Max..8 MPa Connection Rc /8 Connection Rc /4 Connection Rc /8 Connection Rc / Pressure gauge Pressure gauge reverse mounted Connection NPT /8 Connection NPT /4 Connection NPT /8 Connection NPT / Connection G /8 Connection G /4 Connection G /8 Connection G / Symbol 4 B G R N N N N4 F F F F4 <Combination example> einterface rinterface with bracket Modular and Accessory Combinations Description. Air filter. Mist separator. Interface 4. Interface with bracket --X AF AFM Y YT Applicable model --X AF AFM Y YT --X AF4 AFM4 Y4 Y4T Note ) Use the made-to-order product (-X) for modular connections. The interface and interface with bracket listed above cannot be connected to the standard type. Use a conventional connection interface when connecting the standard type with modular connections. Note ) The made-to-order product number (-X) is for the precision regulator only. For modular connections, please order the applicable products and accessories separately. wafm AF --X AF wafm --X 4 AF4 wafm4 5 Accessory /Part No. --X Description Part no. / / Pressure gauge G-- P6 G-4- G-- G4-- P68 G4-4- G4-- G4-- P6- G4-4- G4-- A bracket and two mounting screws (M5 x 5) To mount the bracket, remove two body screws (M5 x ) on the name plate on the opposite side and replace the attached two bracket mounting screws (M5 x 5). Accuracy ±% (Full span) 554

7 Precision Regulator Series // Construction Replacement Parts No. Description Material i!5 SUP side SUP() u Valve guide Exhaust Diaphragm assembly Diaphragm assembly Diaphragm Valve Valve Valve Damper O-ring O-ring O-ring O-ring O-ring Seal (A) Seal (B) Fixed throttle OUT side w OUT() r! Working principle (For ) When the setting knob is turned, the nozzle is closed by the flapper allowing the supply air that flows in from the upstream side to pass through the fixed throttle. It then acts on diaphragm B as nozzle back pressure, the main valve is pushed down by the generated force, and the supply pressure flows out to the downstream side. The air pressure that flows in acts on diaphragm C. While opposing the force generated by diaphragm B it also acts on diaphragm A, opposing the compression force of the setting spring and becomes the set pressure. If the set pressure rises too high, diaphragm A is pushed up, the interval between the flapper and the nozzle widens, the nozzle back pressure drops, the balance of diaphragms B and C is broken, the main valve closes, the exhaust valve opens and the excess pressure from the downstream side is discharged to the atmosphere. In this way fine pressure variations are detected by the nozzle/flapper type pilot mechanism, and precise pressure adjustment is performed. i i NBR, other NBR, other NBR, other Stainless steel, NBR Brass, NBR Brass, NBR NBR, other H-NBR NBR NBR NBR NBR NBR NBR Stainless steel Repair kit no. (A set of above nos. to!5.)!5fixed throttle!5 SUP side e w r u! SUP() e w u! Part no. Qty. Part no. Qty. Part no. Qty. Part no. Qty. Part no. Qty. P6- P6- P658 P6 ø.5 x.5 ø x. P68 i Valve guide SUP side SUP() i Valve guide P6- P6-5 P69 P668# P66 ø.4 x.5 ø4.5 x JISB4P P68 o o OUT side Setting knob Diaphragm (A) Steel ball Nozzle Diaphragm (B) Exhaust Diaphragm (C) OUT() Exhaust Valve Main valve OUT side IN OUT() o o P6- P6- P69# P6# ø4.5 x ø7.8 x.5 JISB4P5 Note) JISB4P6 Note) P65 P66 P67!5!5 SUP side!!! SUP()!! Valve guide SUP side!!! SUP()!! Valve guide!4!4 P6- P6-5 P69 P668# P66 ø.4 x.5 ø4.5 x JISB4P P68 OUT side w y OUT() t OUT side IN w y OUT() t o o P6- P6- P69# P6# ø4.5 x ø7.8 x.5 JISB4P5 Note) JISB4P6 Note) P65 P66 P67 KT- KT- KT- KT- KT- AR45 to 95 V VEX ARX VY AP Note) Use mini-flick type. 555

8 OUT Series // Dimensions SUP() EXH ø8.5 x Rc /8 Pressure gauge port Mounting hole Pressure gauge OUT() Panel mounting hole Max.4 ø Panel When mounting on a panel, refer to page 56 in Specific Product Precautions. ø M5 x P x Rc /8 SUP() 5 Mounting hole ø9.5 ø.5 Panel mounting hole Pressure gauge Panel When mounting on a panel, refer to page 56 in Specific Product Precautions. OUT() ø4 x Rc /8 Pressure gauge port Max.4 M6 x P Exhaust x Rc / Mounting hole Panel mounting hole Max.4 ø.5 Pressure gauge Panel When mounting on a panel, refer to page 56 in Specific Product Precautions. - SUP() ø9.5 Mounting hole Pressure gauge IN OUT() ø4 x Rc /8 Pressure gauge port M5 depth 7 Exhaust x Rc /4 SUP() 9 ø5.5 OUT() ø4 M6 x P 76 EXH() Mounting hole Pressure gauge x Rc /8 Pressure gauge port 66 Rc / Exhaust port x Rc /4 to / SUP() 66 9 ø5.5 IN OUT() M5 depth 7 ø x Rc /8 Pressure gauge port EXH() Rc / Exhaust port x Rc /4 to /

9 Precision Regulator Series // Series Flow Characteristics Testing methods conform to JIS B 87. Relief Characteristics - Supply pressure: MPa - Back pressure: MPa - Pressure Characteristics Supply pressure: MPa Set pressure: MPa Flow rate: l/min (ANR) Supply pressure: MPa - Back pressure: MPa Supply pressure:. MPa - Back pressure:. MPa Set pressure P (MPa) Set pressure P (MPa) Set pressure P (MPa) Supply pressure P (MPa)..8.9 Supply pressure P (MPa)..8.9 Supply pressure P (MPa)... AR45 to 95 V VEX ARX VY AP 557

10 Series // Series Flow Characteristics Testing methods conform to JIS B 87. Relief Characteristics - Supply pressure: MPa - Back pressure: MPa - Pressure Characteristics Supply pressure: MPa Set pressure: MPa Flow rate: l/min (ANR) Set pressure P (MPa) Supply pressure P (MPa) - Supply pressure: MPa - Back pressure: MPa -. Set pressure P (MPa) Supply pressure P (MPa) - Supply pressure:. MPa - Back pressure:. MPa Set pressure P (MPa) Supply pressure P (MPa). - Supply pressure:. MPa - Back pressure:. MPa Set pressure P (MPa) Supply pressure P (MPa). 558

11 Precision Regulator Series // Series Flow Characteristics Testing methods conform to JIS B 87. Relief Characteristics - Supply pressure: MPa - Back pressure: MPa - Pressure Characteristics Supply pressure: MPa Set pressure: MPa Flow rate: l/min (ANR) Supply pressure: MPa - Back pressure: MPa Supply pressure:. MPa - Back pressure:. MPa Supply pressure:. MPa - Back pressure:. MPa Set pressure P (MPa) Set pressure P (MPa) Set pressure P (MPa) Set pressure P (MPa) Supply pressure P (MPa)..8.9 Supply pressure P (MPa)..8.9 Supply pressure P (MPa)... AR45 to 95 V VEX ARX VY AP Supply pressure P (MPa) 559

12 OUT OUT OUT OUT OUT Series // Made to Order Specifications: Please contact SMC regarding detailed dimensions, specifications, and delivery times. Clean Series Standard model no. Note) Please contact SMC if a product with pressure gauge is desired. Clean Series Specifications Cleanliness hole EXH port Grease Class With M5 fitting (Applicable tubing O.D. ø6) /: With M5 fitting (Applicable tubing O.D. ø6) : Rc / female thread Teflon grease External and internal copper parts are changed to stainless steel or aluminum. 4 Copper-free and Fluorine-free Standard model no. Note) Please contact SMC if a product with pressure gauge is desired. Copper-free and Fluorine-free Fluoro rubber is used for rubber seal materials. 8 Ozone Resistant Standard model no. For High/Low Temperature Environments Standard model no. Specifications Symbol Environment Ambient temperature Rubber material 5 Ozone resistant T For high/low temperature environments T L T For high temp. environments 5 to C (Max. 8 C with pressure gauge) Fluoro rubber Non-grease Specifications For high temperature For low temperature L For low temp. environments to 6 C Special NBR Assembly is performed in an ordinary environment without using grease. However, since parts are not washed, they are not completely oil-free. Standard model no. 56 X Non-grease specifications 6 With digital pressure switch (model no: ISEA---ML). Mount a digital pressure switch into the connection port for pressure gauge, as it is not mounted at the time of shipment. Specifications Made to order part no. Pressure switch 7 Manifold Specifications (Except type and series ) to 8 station manifold type regulators. (Please contact SMC regarding 9 or more stations.) M G Manifold type regulator Specifications Stations Port With Digital Pressure Switch Set pressure range (MPa) Desolution of setting and display (MPa) Current consumption How to Order 8 Body size Set pressure Power supply voltage Standard model no. Note) Note) Except for symbol G Note ) Please contact SMC separately for details about the external dimensions, etc. Note ) For details on handling digital pressure switch and specifications, refer to the catalog (CAT.E-7): Series ISEA. Note ) Digital pressure switch is packed togther. Accessory (Pressure gauge) Set pressure and uantity MPa setting to n pcs. MPa setting to n pcs..8 MPa setting to n pcs. Example ) MPa setting with 6 stations M-6G-6 Example ) MPa setting pcs., MPa setting pcs.,.8 MPa setting pc. with 5 stations M-5G- Accessory (Pressure gauge) stations Nil None : G-- 8 stations G : G4-- Accessory (pressure gauge) is included, (but not assembled). Thread type (Thread on the manifold base) Stations Nil N F X465. to. to 4 VDC ±%, Ripple (p-p) % or less (With reverse connection protection) 4 ma or less X465 A With digital pressure switch Switch specifications Symbol A B C D Rc NPT G Output specifications NPN open collector output PNP open collector output NPN open collector output + Analog voltage output NPN open collector output + Analog current output to 8 stations Common SUP : /4, : / Individual OUT : /8, : /4 Individual EXH (From body) MPa, MPa and.8 MPa settings can be combined. G-- (), G4-- () Note ) Regulators to be manifolded are counted starting from stations on the left side with the OUT ports in front. Note ) When regulators with a different set pressure are manifolded, viewing OUT ports from front, the low pressure range is installed on the left side and high pressure range is on the right side. In case of the Example ) above mentioned, stations and are of MPa setting, stations and 4 are of MPa setting, and station 5 is of.8 MPa setting. Note ) Please consult with SMC when a blanking plate is needed.

13 Series // Specific Product Precautions Be sure to read before handling. Refer to front matters 4 and 4 for Safety Precautions and pages 87 to 9 for Precautions on every series. Warning Caution Warning Warning Caution Air Supply. If the drain removal from air filter and mist separator is missed, drain will be flown out to the outlet side and may result in a malfunction of the pneumatic euipment. When removing drain is difficult, use of a filter with an autodrain is recommended.. If the supply pressure line contains drain or particlate, etc., the fixed throttle can become clogged leading to malfunction, and therefore, in addition to an air filter (SMC Series AF) be sure to use a mist separator (SMC Series AM, AFM). Refer to pages and regarding air uality.. Never use a lubricator on the supply side of the regulator, as this will positively cause the fixed throttle to become clogged and result in a malfunction. If lubrication is reuired for terminal devices, connect a lubricator on the output side of the regulator. Maintenance. When the valve guide (refer to construction drawing on page 555) is to be removed during maintenance, first reduce the set pressure to and completely shut off the supply pressure.. When a pressure gauge is to be mounted, remove the plug after reducing the set pressure to. Precautions for only. When remounting the valve guide after removing it for maintenance, use a tightening torue of no more than N m. Since the valve guide on this product is made of resin, there is a danger of damage if tightened with a torue exceeding the prescribed value. Handling. Do not apply force when transferring, mounting and dropping the regulator with a pressure gauge. This may cause misalignment of the pressure gauge pointer. Caution Caution Operation. Do not use a precision regulator outside the range of its specifications as this can cause failure. (Refer to specifications.). When mounting is performed, make connections while confirming port indications.. Screw a panel nut with the recommended proper torue when mounting onto a panel. Looseness or faulty sealing will occur if tightening torue is insufficient, while thread damage will result if the torue is excessive. Recommended Proper Torue (N m).5 4. If a directional switching valve (solenoid valve, mechanical valve, etc.) is mounted on the supply side of the regulator and repeatedly switched ON and OFF, wear of the nozzle/flapper section will be accelerated and a discrepancy in the setting value may occur. Therefore, avoid using a directional switching valve on the supply side. In the event a directional switching valve will be used, install it on the output side of the regulator. 5. Air is normally released from the bleed hole (the hole on the side of the body s mid-section). This is a necessary consumption of air based on the construction of the precision regulator, and is not an abnormality. 6. Make sure to tighten the lock nut after pressure adjustment. Precautions for, only. The supply pressure is relatively high (approx. MPa or more), the set pressure is low (approx.. MPa or less), and when operated with the output side released to the atmosphere, there may be pulsations in the setting pressure. In this kind of situation, operate with the supply pressure reduced as much as possible, or increase the set pressure somewhat and restrict the output line (add and adjust a stop valve, etc.).. The capacity of the output side is large, and when used for the purpose of a relief function, the exhaust sound will be loud when being relieved. Therefore, operate with a silencer (SMC Series AN) mounted on the exhaust port (EXH port). The connection is Rc /. Precautions for, (air operated type) only Caution. Since the output types of and are the same pressure as the input signal pressure, select a type of regulator (general purpose or precision type) for input signal pressure adjustment according to the application.. The screw on the topmost section is a zero point adjustment screw which is locked at the factory and reuires no adjustment for operation. AR45 to 95 V VEX ARX VY AP 56

Direct Operated Regulator for 6.0 MPa (Relieving Type) How to Order. Body size 30 40

Direct Operated Regulator for 6.0 MPa (Relieving Type) How to Order. Body size 30 40 Direct Operated Regulator for (Relieving Type) Series Service life: 0 million cycles Using NSF-H-certified grease on the guide ring (sliding) part. Improved durability under a high environment with a polyurethane

More information

Pilot Operated 2 Port Solenoid Valve for Dry Air

Pilot Operated 2 Port Solenoid Valve for Dry Air Pilot Operated Port Solenoid Valve for Dry Air Series VQ0/30 Compact and lightweight with large flow capacity [Option] VQ0 Weight (g) 46 80 C [dm 3 /(s bar)].5 (C8) 3.0 (C) Series Series VQ0 VCH VDW VQ

More information

Compressed Air Cleaning Filter Series

Compressed Air Cleaning Filter Series Compressed Air Cleaning ilter Series Series / or Water, Solid/Oil Separation and Deodorization Modular connection, Space-saving design, Labor-saving in piping! Uses the same spacer as the.r.l. combination

More information

Water Separator. Main Line Filter. Mist Separator. Micro Mist Separator 150C 250C 350C 450C AMG 550C 2C 4C 8C 11C AFF 22C 37B 75B 150C 250C 350C 450C

Water Separator. Main Line Filter. Mist Separator. Micro Mist Separator 150C 250C 350C 450C AMG 550C 2C 4C 8C 11C AFF 22C 37B 75B 150C 250C 350C 450C Water droplet removal Water Separator Water droplet separation rate: % Model Flow capacity l/min (ANR) Max. flow capacity at 0.7 MPa inlet pressure 300 750 1,500 AMG 2,0 AMG to AMG/ Large dust particle

More information

Specifications. Model Flow type Pressure type. Air Maximum operating pressure. 1.0 MPa Ambient and fluid temperature. 3% F.S.

Specifications. Model Flow type Pressure type. Air Maximum operating pressure. 1.0 MPa Ambient and fluid temperature. 3% F.S. Electro-Pneumatic Proportional Valve Series /VEP Electro-pneumatic proportional valve: Flow type () Controls the flow rate steplessly according to current. (It is a / port valve that has an electrical

More information

Compact, pressure gauge embedded. Port size: 1/8 to 1. Note 1 Set pressure range Relief to 0.85 With relief mechanism 1/8, 1/4 0.

Compact, pressure gauge embedded. Port size: 1/8 to 1. Note 1 Set pressure range Relief to 0.85 With relief mechanism 1/8, 1/4 0. Regulator standard white Series R/R/R R/R/R-W Series, pressure gauge embedded. : / to JIS symbol Specifications Descriptions R-W R-W R-W R-W R-W R-W Working fluid Compressed air Max. working pressure Withstanding

More information

5 Port Pilot Operated Solenoid Valve Rubber Seal. Specifications Fluid Operating pressure range. 2 position single/3 position 2 position double

5 Port Pilot Operated Solenoid Valve Rubber Seal. Specifications Fluid Operating pressure range. 2 position single/3 position 2 position double For details about certified products conforming to international standards, visit us at www.smcworld.com. 5 Port Pilot Operated Solenoid Valve Rubber Seal Series VF3000 Compact and lightweight: 26.4 mm

More information

Inrush Apparent power (VA) Flow Characteristics/Weight. Port size Rc. Valve model VS3115-01 VS3115-02 VS3110-02 VS3110-03 VS3114-00.

Inrush Apparent power (VA) Flow Characteristics/Weight. Port size Rc. Valve model VS3115-01 VS3115-02 VS3110-02 VS3110-03 VS3114-00. Port Direct Operated Solenoid Valve Series VS5/0 Metal Seal Multiple pressure supply is possible with balanced spool sleeve. Any given port can accept high or low pressure supply without affecting the

More information

Q1 Q2 Q3. 2 stage performance. 3 stage performance. Suction flow rate. 250% suction flow rate increase. Release flow rate adjusting needle.

Q1 Q2 Q3. 2 stage performance. 3 stage performance. Suction flow rate. 250% suction flow rate increase. Release flow rate adjusting needle. Multistage Ejector Series 112/212 Energy-saving, large flow rate, 3 stage diffuser construction Suction flow rate increased 25% and air consumption reduced 2% with 3 stage diffuser construction (ersus

More information

Proportional pressure regulators VPPE

Proportional pressure regulators VPPE Proportional pressure regulators VPPE Proportional pressure regulators VPPE Product range overview Function Version Pneumatic connection Proportional pressure regulator Nominal size for pressurisation/

More information

AIR-AIR PRESSURE MULTIPLIER (BOOSTER)

AIR-AIR PRESSURE MULTIPLIER (BOOSTER) AIR-AIR PRESSURE MULTIPLIER (BOOSTER) The air-air pressure multiplier, or booster, is an automatic device that compresses air to give an outlet pressure that is double the inlet pressure. It is normally

More information

Micro Mist Separator with Prefilter AMH Model (1) Rated flow (l/min(anr)) Port size (Nominal size B) Weight (kg)

Micro Mist Separator with Prefilter AMH Model (1) Rated flow (l/min(anr)) Port size (Nominal size B) Weight (kg) Micro Mist Separator with Prefilter AMH Series AMH can separate and remove aerosol state oil mist in compressed air and remove carbon or dust of more than 0.01µm. It should be used as prefilter of compressed

More information

CAT.ES120-4 A. Precision Clean Regulator. Series SRP. High precision, low flow consumption stainless steel regulator

CAT.ES120-4 A. Precision Clean Regulator. Series SRP. High precision, low flow consumption stainless steel regulator CAT.ES120-4 A Precision Clean Regulator Series SRP High precision, low flow consumption stainless steel regulator Precision Clean Regulator Series SRP High precision, low flow consumption stainless steel

More information

SOLENOID VALVES SERIES

SOLENOID VALVES SERIES CAD drawing data catalog is available. VALVES GENERAL CATALOG SOLENOID VALVES SERIES INDEX SOLENOID VALVES 010 SERIES Features 61 Basic Models and Configuration 62 Specifications 63 Solenoid Valve/Manifold

More information

Standard Specifications Model. How to Order. Mist spray unit. Recommended Equipment. Mixing valve

Standard Specifications Model. How to Order. Mist spray unit. Recommended Equipment. Mixing valve Mist Spray Unit Series MU/ Intermittent spray to cutting and press gear chains, etc. Standard Specifications MU MU Inlet air Oil tank set range. MPa. to. MPa Oil tank capacity (cm ) Total capacity: Effective

More information

Model 43AP Pneumatic Controller, Style B

Model 43AP Pneumatic Controller, Style B Instruction MI 011-476 January 1980 Model 43AP Pneumatic Controller, Style B Installation and Operation Model 43AP Controller continuously detects the difference between a process measurement and its set

More information

3 Port Solenoid Valve

3 Port Solenoid Valve Port Solenoid Valve Series V00 Rubber Seal Power consumption 0. W (with power saving circuit) VV0 VV00 V00 -V F VS temperature rises: C (with power saving circuit) Sonic conductance Series Standard Large

More information

Particulate Filter PSI Metal Bowl GENERAL PURPOSE PARTICULATE FILTERS

Particulate Filter PSI Metal Bowl GENERAL PURPOSE PARTICULATE FILTERS Series 57 Particulate Filter - 250 PSI GENERAL PURPOSE PARTICULATE FILTERS General purpose filters remove harmful water condensate, pipe scale, dirt and rust from your compressed air system. This prevents

More information

Type 4708 Supply Pressure Regulator

Type 4708 Supply Pressure Regulator Type 478 Pressure Regulator Application pressure regulator used to provide pneumatic measuring and control equipment with a constant air supply Set point ranges. to.6 bar ( to 4 psi) or. to 6 bar (8 to

More information

W1000/W3000/W4000/W8000-W Series New Series of 5 m elements for dust removal, and 0.3 m elements for tar removal. Port size: 1/8 to 1

W1000/W3000/W4000/W8000-W Series New Series of 5 m elements for dust removal, and 0.3 m elements for tar removal. Port size: 1/8 to 1 Filter/ standard white Series W/W/W/W-W Series New Series of m elements for dust removal, and m elements for tar removal. : / to JIS symbol nic sensor Pressure Specifications Descriptions W-W W-W W-W W-W

More information

UM/22000 5/2 or 5/3 Solenoid and air pilot actuated soft spool valves

UM/22000 5/2 or 5/3 Solenoid and air pilot actuated soft spool valves U/ / or / > > Sub-base mounted, 99- s,, or > > Steel reinforced main seals > > Low power coils (,W) > > Wide range of sub-bases and accessories > > 6 bar and bar NOO solenoid pilots with locking or non-locking

More information

FLUTEC Pressure Relief Valves

FLUTEC Pressure Relief Valves FLUTEC Pressure Relief Valves Pressure Relief DB4E 1.1. up to 630 bar up to 30 l/min Connection housings 2 1. DESCRIPTION 1.1. GENERAL According to DIN -ISO 1219, DB4E are valves for oil hydraulic systems

More information

ASL Series Pump. Operation and Maintenance Manual Air Driven, High Pressure Liquid Pump

ASL Series Pump. Operation and Maintenance Manual Air Driven, High Pressure Liquid Pump ASL Series Pump Operation and Maintenance Manual Air Driven, High Pressure Liquid Pump Catalog: 02-9233ME February 2013 Model # Serial # Drawing # Order # Mfg. Date Table of Contents page 1.0 Introduction...

More information

Needle valve with adjusting dial

Needle valve with adjusting dial Easy to read flow adjustment/control achieved. Needle valve with adjusting dial DVL Series New Product NEEDLE VALVE WITH ADJUSTING DIAL CC-860A Realizing visible flow rate adjustment and control The needle

More information

Series IZS31 Technical Data 1

Series IZS31 Technical Data 1 Series IZS Technical Data Static electricity Removal Characteristics Note) Static electricity elimination features are based on data from using a charged plate (size: mm x mm, capacitance: pf) as defined

More information

A-4000 Series Oil Removal and Pressure-Reducing Stations and Air Compressor Accessories

A-4000 Series Oil Removal and Pressure-Reducing Stations and Air Compressor Accessories A-4000 Series Oil Removal and Pressure-Reducing Stations and Air Compressor Accessories Product Code No. LIT-718060 Issued September 27, 2013 Supersedes September 26, 2007 Refer to the QuickLIT website

More information

3 Way Proportional Pressure Control Valve Nominal diameter 2 Direct operated poppet valves Flange design Low hysteresis

3 Way Proportional Pressure Control Valve Nominal diameter 2 Direct operated poppet valves Flange design Low hysteresis VP0 Way Proportional Pressure Control Valve Nominal diameter Direct operated poppet valves Flange design Low hysteresis Good repeatability High flow capacity at exhaust port Manifold mountable system Compact

More information

100 kpa to 1.0 MPa Both positive pressure and vacuum pressure can be used with one unit!

100 kpa to 1.0 MPa Both positive pressure and vacuum pressure can be used with one unit! In-line Air Filter Series For tubing sizes ø2 and ø3.2, refer to Air Suction Filter/Series on SMC website. Operating pressure range kpa to 1. MPa Both positive pressure and vacuum pressure can be used

More information

3-step setting. 2-Color Display High-Precision Digital Pressure Switch. Series ZSE30A(F)/ISE30A. Added vacuum range.

3-step setting. 2-Color Display High-Precision Digital Pressure Switch. Series ZSE30A(F)/ISE30A. Added vacuum range. 2-Color Display High-Precision Digital Pressure Switch Series ZSE3A(F)/ISE3A RoHS Can copy to up to 1 switches simultaneously. The settings of the master sensor can be copied to the slave sensors. Reducing

More information

% ^ ) 0.55 W Low Power Solenoid Valves Aluminum, Brass, or Stainless Steel Bodies 1/4" to 1" NPT. 2/2 3/2 4/2 5/2 5/3 SERIES Low Power

% ^ ) 0.55 W Low Power Solenoid Valves Aluminum, Brass, or Stainless Steel Bodies 1/4 to 1 NPT. 2/2 3/2 4/2 5/2 5/3 SERIES Low Power .55 W Solenoid Valves Aluminum, Brass, or Stainless Steel Bodies /" to " NPT / 3/ / 5/ 5/3 Features Molded one-piece solenoid with highly efficient solenoid cartridge and.55 W low wattage coil Standard

More information

Single sub-base valve

Single sub-base valve solenoid valves Mini-valves 10 mm Electrical connection... Mounting... Port sizes... Rated temperature... Fluid... Working pressure... Nominal flow... Pneumatic connections Voltage... Power... NC poppet

More information

Electro-Pneumatic Pressure Control Valves (Pages from SC-Master2 Catalog) The Drive & Control Company

Electro-Pneumatic Pressure Control Valves (Pages from SC-Master2 Catalog) The Drive & Control Company Electro-Pneumatic Pressure Control Valves (Pages from SC-Master2 Catalog) The Drive & Control Company E/P (Electro-Pneumatic) Pressure Control Valves Index Page Series ED02, proportional solenoid, analog

More information

TECHNICAL DATA. Q = C v P S

TECHNICAL DATA. Q = C v P S January 6, 2012 Preaction 332a 1. Description Viking Supervised Surefire Preaction Systems Utilize the Viking G-2000P Valve. The small profile, lightweight, pilot operated Viking G-2000P Valve comes complete

More information

4 Posiflow Proportional Solenoid Valves

4 Posiflow Proportional Solenoid Valves 4 Posiflow Solenoid Brass or Stainless Steel Bodies 1/4" to 1/2" NPT 2/2 Features Flow rates adjustable between 0% and 100% of rating Flow rate can also be regulated by a range of electrical inputs (sensors,

More information

SUBJECT: HYDRAULIC CHECK VALVES AND FLOW CONTROL VALVES

SUBJECT: HYDRAULIC CHECK VALVES AND FLOW CONTROL VALVES SUBJECT: HYDRAULIC CHECK VALVES AND FLOW CONTROL VALVES ABOUT THE SESSION This session deals with check valves, flow control valves, its functions, operations and application. INTRODUCTION Check Valve:

More information

Universal type. Elbow type AS13 1FG-M5 AS23 1FG-01 AS23 1FG-02 AS33 1FG-02 AS33 1FG-03 AS43 1FG-04. Specifications

Universal type. Elbow type AS13 1FG-M5 AS23 1FG-01 AS23 1FG-02 AS33 1FG-02 AS33 1FG-03 AS43 1FG-04. Specifications Speed Controller with One-touch Fitting Stainless Steel Series Elbow Type/Universal Type Series -FG RoHS Stainless specifications for use in corrosive environments. Stainless steel used for metal parts.

More information

THE BASICS OF PRESSURE REGULATORS

THE BASICS OF PRESSURE REGULATORS THE BASICS OF PRESSURE REGULATORS Contents The Basics of Pressure Regulators Material Fluid used (gas, liquid, toxic or flammable) Temperature Operating Pressures Flow Requirements Size & Weight Pressure

More information

Typical Aluminum GFM Mass Flow Meter

Typical Aluminum GFM Mass Flow Meter MASS FLOW METERS Design Features n Rigid metallic construction. n Maximum pressure of 1000 psig (70 bars). n Leak integrity 1 x 10-9 of helium. n NIST traceable certification. n Built-in tiltable LCD readout.

More information

System 6000 Electropneumatic Converter for Direct Current Signals Type 6111 i/p Converter

System 6000 Electropneumatic Converter for Direct Current Signals Type 6111 i/p Converter System 6000 Electropneumatic Converter for Direct Current Signals Type 6111 i/p Converter Application Used to convert a direct-current input signal into a pneumatic output signal for measuring and control

More information

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics 3/2-, 5/2-5/3-way Solenoid Valves for process pneumatics Type 6518 stard High flow-rate capacity Reduced power consumption Single or manifold mounting stard Type 6518/6519 can be combined with... Stard-,

More information

10 switches simultaneously. The settings of the master sensor (source of copy) can be copied to the slave sensors. Reducing setting labor

10 switches simultaneously. The settings of the master sensor (source of copy) can be copied to the slave sensors. Reducing setting labor 2-Color Display High-Precision Digital Pressure Switch ZSE ISE RoHS New IP65 ZSE40 ISE40 ZSE10 ISE10 M8 connector type ISE70 ZSE80 ISE80 ZSE ISE ZSP PS ISA2 PSE Applicable Air, Non-corrosive gas, Non-flammable

More information

0.35 0.9. 3 Port Solenoid Valve. Series VQZ100/200/300. Compact, High Flow. Power consumption: 0.35 W/0.9 W SYJ VQZ VP VG VP3

0.35 0.9. 3 Port Solenoid Valve. Series VQZ100/200/300. Compact, High Flow. Power consumption: 0.35 W/0.9 W SYJ VQZ VP VG VP3 Port Solenoid Valve 00/00/00 Metal Seal Rubber Seal 0. 0.9 (Standard) (High pressure type, High speed response type) Power consumption: 0. W/0.9 W Compact, High Flow Body ported Base mounted 00 00 00 00

More information

Valve systems Base plates, according to standard ISO 5599-1. Brochure

Valve systems Base plates, according to standard ISO 5599-1. Brochure ISO 5599-1 Brochure 2 ISO 5599-1 Single subbase Single subbase, thread connections on the side standard: ISO 5599-1 Frame size: ISO 1 - ISO 4 compressed air connection output: G 1/4 - G 1 Reversed pressure

More information

% ^ ) 1.4 W Low Power Solenoid Valves Aluminum, Brass, or Stainless Steel Bodies 1/4" to 1" NPT. 2/2 3/2 4/2 5/2 5/3 SERIES Low Power

% ^ ) 1.4 W Low Power Solenoid Valves Aluminum, Brass, or Stainless Steel Bodies 1/4 to 1 NPT. 2/2 3/2 4/2 5/2 5/3 SERIES Low Power 4.4 W Solenoid Valves Aluminum, Brass, or Stainless Steel Bodies /4" to " NPT / 3/ Features Molded one-piece solenoid with highly efficient solenoid cartridge and special low wattage coil Increased ambient

More information

4/2-Way Pneumatic Solenoid Valve

4/2-Way Pneumatic Solenoid Valve 4/2-Way Pneumatic Solenoid Valve Robust servo assisted piston valve Service friendly manual override Single or block assembly Explosion-proof versions Type 5413 cam be combined with Type 2508 Cable plug

More information

G1/4 Q8. Standard with biased position

G1/4 Q8. Standard with biased position Contents Version Actuation Page Characteristics Dimensions x / Way Valves pneumatic 6,7, 0 9 electric 6,7 9, 9 / Way Valves pneumatic 6,7, 0 electric 6,7, 0 / Way Valves pneumatic 6,7,, 6, 7 electric 6,7,,

More information

INSTALLATION INSTRUCTIONS. CVS 67CFR Pressure Reducing Instrument Supply Regulator INTRODUCTION

INSTALLATION INSTRUCTIONS. CVS 67CFR Pressure Reducing Instrument Supply Regulator INTRODUCTION INSTALLATION INSTRUCTIONS CVS 67CFR Pressure Reducing Instrument Supply Regulator INTRODUCTION The CVS Controls 67CFR Filter regulator is a pressure reducing supply regulator typically used for pneumatic

More information

Direct Operated 3 Port Solenoid Valve For Air, Water, Oil, Steam

Direct Operated 3 Port Solenoid Valve For Air, Water, Oil, Steam CAT.ES0-6 Direct Operated Port Solenoid Valve For Air, Water, Oil, Steam Reduced power consumption ( specification). W. 8 W W 0. W.. W 6 W New VX Series VX/ / Reduced power consumption Improved corrosion

More information

U.L. Listed Beverage Regulators Cylinder Gas Pressure (CO 2 ) Regulators for Soft Drink and Beer dispensing systems.

U.L. Listed Beverage Regulators Cylinder Gas Pressure (CO 2 ) Regulators for Soft Drink and Beer dispensing systems. Section 12 U.L. Listed Beverage Regulators Cylinder Gas Pressure (CO 2 ) Regulators for Soft Drink and Beer dispensing systems. R84 Regulator and C84 Regulator Configurations for Soft Drink Carbonator

More information

LCD Readout Digital Pressure Switch

LCD Readout Digital Pressure Switch LCD Readout Digital Pressure Switch Series ZSE3 (For )/E3 (For Positive Pressure) For General Pneumatics Easy pressure setting with the digital display RoHS Can be integrated with a vacuum unit, Series

More information

Transmitters: Shuttle Valve VR1210/1220

Transmitters: Shuttle Valve VR1210/1220 Transmitters: Shuttle Valve VR1210/1220 3 porte check valve with one output an 2 pneumatic signal input ports. Output always supplie by high pressure inlet. /Specifications Max. operating pressure Min.

More information

Index 11.1. Page. Pumping Systems...11.2-11.4 Intensifiers...11.5 Gas Boosters...11.6-11.7 High Pressure Generators...11.8-11.9

Index 11.1. Page. Pumping Systems...11.2-11.4 Intensifiers...11.5 Gas Boosters...11.6-11.7 High Pressure Generators...11.8-11.9 Pumping Systems, Intensifiers, Gas Boosters and High Pressure Generators High Pressure Equipment Company produces a number of components and systems for general industrial, elevated pressure applications.

More information

3 Port Solenoid Valve

3 Port Solenoid Valve ubber Seal ort Solenoid Valve Series SYJ00/00/700 [Option] SYJ VQZ V VG Improved pilot valve ilot valve cover is stronger using stainless steel. Mounting thread is also reinforced from size M1.7 to M.

More information

T-Series Precision Linear Actuators Installation and Service Manual DW110353GB-1018 - EDITION 5. www.thomsonlinear.com

T-Series Precision Linear Actuators Installation and Service Manual DW110353GB-1018 - EDITION 5. www.thomsonlinear.com T-Series Precision Linear Actuators Installation and Service Manual DW110353GB-1018 - EDITION 5 www.thomsonlinear.com Version History Edition Number Edition Date Reason for Revision 1 2004 First edition

More information

Digital flow ELEMENT transmitter for continuous flow measurement

Digital flow ELEMENT transmitter for continuous flow measurement Digital flow ELEMENT transmitter for continuous flow measurement Type 8026 can be combined with... PN10, DN15 to DN400 fluidic process connection Programmable outputs : one or two transistor output(s)

More information

Gems Sensors offers a complete line of products for these industries:

Gems Sensors offers a complete line of products for these industries: Model 830 Instruction Bulletin No. 197070 Rev. A Wet/Wet Differential Pressure Transducer Gems Sensors offers a complete line of products for these industries: Industrial HVAC Test & Measurement Barometric

More information

Pressure transmitter (2 wire) / switch for continuous or On/Off Control

Pressure transmitter (2 wire) / switch for continuous or On/Off Control transmitter (2 wire) / switch for continuous or On/Off Control Indication, monitoring, transmitting and continuous or On/Off control in one device Output signal 4...20 ma, 2-wire for continuous control

More information

5.0 MPa Pilot Operated 2/3 Port Solenoid Valve & Check Valve

5.0 MPa Pilot Operated 2/3 Port Solenoid Valve & Check Valve 5.0 Ma ilot Operated /3 ort Solenoid Valve & Check Valve Series VCH VCH4/4: ort VCH40: 3 ort VCHC40: Check Valve ilot Operated ort Solenoid Valve [Option] Series VCH40 Stable responsiveness Response time

More information

2/8.10.01. These vacuum switches are used in measuring ranges between -1 and 0 bar.

2/8.10.01. These vacuum switches are used in measuring ranges between -1 and 0 bar. CATALOGUE > Release 8.5 > Electronic vacuum switches Series SWM Electronic miniature vacuum switches Series SWM These vacuum switches are used in measuring ranges between -1 and 0 bar. Small dimension

More information

Electro-pneumatic control valves

Electro-pneumatic control valves Electropneumatic control valves 7 Miniature solenoid valves for alternating current Conform to the Low Voltage Directive or mounting on subbase or footprint in accordance with CNOMO recoendation E 066120N

More information

TECHNICAL DATA. Dry 122a. November 12, 2013

TECHNICAL DATA. Dry 122a. November 12, 2013 Dry 122a 1. PRODUCT DESCRIPTION The Viking is a quick-opening device. When installed with the required external Anti-flood Device, the assembly is designed to increase the operating speed of Viking Model

More information

Air Compressor Piston Trouble Shooting Guide

Air Compressor Piston Trouble Shooting Guide Motor Will Not Run. Power not on Turn power on (Failure to start) 1 Blown main fuses (size 175% of motor nameplate) Blown control fuses (size per nec article 450-3) Breaker tripped Safety device tripped

More information

PNEUMATIC CONTROL VALVES SERVICE AND MAINTENANCE PROCEDURES

PNEUMATIC CONTROL VALVES SERVICE AND MAINTENANCE PROCEDURES PNEUMATIC CONTROL VALVES SERVICE AND MAINTENANCE PROCEDURES CONFIDENTIALITY NOTICE This document contains subject matter in which KMT Waterjet Systems has proprietary rights. Recipients of this document

More information

Self Purging Liquid Trap (SPLT ) User s Manual

Self Purging Liquid Trap (SPLT ) User s Manual Self Purging Liquid Trap (SPLT ) User s Manual High pressure liquids and gases are potentially hazardous. Energy stored in these liquids and gases can be released unexpectedly and with extreme force. High

More information

Digital flow ELEMENT transmitter for continuous flow measurement

Digital flow ELEMENT transmitter for continuous flow measurement Digital flow ELEMENT transmitter for continuous flow measurement Type 8036 can be combined with... DN06 to DN65 fluidic process connection Programmable outputs : one or two transistor output(s) and single

More information

RoHS compliant. Clean Air Filter. Hollow Fiber Element. Series SFD. Nominal filtration rating: 0.01 µm (filtration efficiency 99.

RoHS compliant. Clean Air Filter. Hollow Fiber Element. Series SFD. Nominal filtration rating: 0.01 µm (filtration efficiency 99. Clean Air Filter Series SFD Hollow Fiber Element Nominal filtration rating: 0.0 µm (filtration efficiency 99.99%) RoHS Initial pressure drop: 0.03 MPa (at inlet pressure 0.7 MPa, maximum flow) Maximum

More information

Fluid Control Products. A Constant Flow Of Ideas. 2 Way General Purpose Solenoid Valves

Fluid Control Products. A Constant Flow Of Ideas. 2 Way General Purpose Solenoid Valves Fluid Control Products A Constant Flow Of Ideas 2 Way General Purpose Solenoid Valves T A B L E O F C O N T E N T S Series General Description Pipe Body Material Page 8030 Low Pressure 3/8" - 3/" Brass

More information

BERMAD Fire Protection

BERMAD Fire Protection 400E-2M/700E-2M IOM Bermad Electrically Controlled Deluge Valve with EasyLock Manual Reset Model: 400E-2M/700E-2M INSTALLATION OPERATION MAINTENANCE Application Engineering BERMAD 400E-2M/700E-2M Bermad

More information

Compact cylinder Double acting single rod type. SSD SSD-L (with switch) Double acting Compressed air 1.0. 1.6-10 to 60 (no freezing) Rc1/8 Rc1/4 Rc3/8

Compact cylinder Double acting single rod type. SSD SSD-L (with switch) Double acting Compressed air 1.0. 1.6-10 to 60 (no freezing) Rc1/8 Rc1/4 Rc3/8 * U S 4 Specifications escriptions Bore size mm Actuation Working fluid ax. working pressure Pa in. working pressure Pa Withstanding pressure Pa Ambient temperature Port size Stroke length Rubber cushioned

More information

Unit 24: Applications of Pneumatics and Hydraulics

Unit 24: Applications of Pneumatics and Hydraulics Unit 24: Applications of Pneumatics and Hydraulics Unit code: J/601/1496 QCF level: 4 Credit value: 15 OUTCOME 2 TUTORIAL 4 DIRECTIONAL CONTROL VALVES The material needed for outcome 2 is very extensive

More information

NB/NBR NITROGEN BOOSTER FOR AVIATION SERVICE

NB/NBR NITROGEN BOOSTER FOR AVIATION SERVICE NB/NBR NITROGEN BOOSTER FOR AVIATION SERVICE INSTALLATION, OPERATION & MAINTENANCE MANUAL INTERFACE DEVICES, INC. 230 Depot Road, Milford, CT 06460 Ph: (203) 878-4648, Fx: (203) 882-0885, E-mail: info@interfacedevices.com

More information

ISO Star Series Valves A long life (100 to 200 million cycles) precision spool and sleeve directional control air valve

ISO Star Series Valves A long life (100 to 200 million cycles) precision spool and sleeve directional control air valve Section 5 ISO Star Series Valves A long life (100 to 200 million cycles) precision spool and sleeve directional control air valve Contents Features and Benefits............VAL-5-2 Specifications and Technical

More information

Pressure sensing and control

Pressure sensing and control Pressure sensing and control A comprehensive range of Pressure Switches, providing a range of different options for converting pressure changes into an electrical signal. The range includes electromechanical

More information

Pneumatic Globe Control Valve

Pneumatic Globe Control Valve Pneumatic Globe Control Valve Installation, Operation and Maintenance Manual USER INFORMATION File: Pneu Globe Control.MAN Location: Assembly/Manual Rev A November 14, 2004 Page 1 of 8 Table of Contents

More information

IMPORTANT DOCUMENTATION DO NOT DISCARD!

IMPORTANT DOCUMENTATION DO NOT DISCARD! PART NO.: 6441-263C SERIES GRT 3 JAW PARALLEL GRIPPERS INFORMATION SHEET IMPORTANT DOCUMENTATION DO NOT DISCARD! Use this information sheet to assist with gripper installation and setup. File with maintenance

More information

PRESSURE REDUCING CONTROL VALVE

PRESSURE REDUCING CONTROL VALVE Schematics Throttles to reduce high upstream pressure to constant lower downstream pressure Low Flow By-Pass controls at low flows 4 PRESSURE REDUCING CONTROL VALVE with LOW FLOW BY-PASS FEATURE Main Line

More information

Air Fuse In-Line Excess Flow Shut off Valve

Air Fuse In-Line Excess Flow Shut off Valve In-Line Excess Flow Shut off Valve 1 4" to 1 1 2" BSPP, NPT Assists in complying with safety regulations Tamper proof Compact and safe design Low pressure drop Automatically resets after failure correction

More information

System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter

System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter Application Used to convert a direct-current input signal into a pneumatic output signal for measuring and control

More information

INLINE flowmeter for continuous flow measurement

INLINE flowmeter for continuous flow measurement INLINE flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both PNP and NPN) Connection

More information

Process Valve. 2 Port Valve For Compressed Air and Air-hydro Circuit Control

Process Valve. 2 Port Valve For Compressed Air and Air-hydro Circuit Control Process Valve Series VN Port Valve For Compressed ir and ir-hydro Circuit Control Exclusively for air pressure system and air-hydro circuit control Universal Port Valve [Option] Cylinder actuation by external

More information

OPL BASIC. Dosing System for Professional Laundry machines. Contents

OPL BASIC. Dosing System for Professional Laundry machines. Contents OPL BASIC Dosing System for Professional Laundry machines Contents 1 Getting Started. Page 2 2 Installation. Page 4 3 Set Up & Operation. Page 8 4 Maintenance & Accessories. Page 10 5 Troubleshooting Page

More information

Shut-off & Lockout Valves 1/4" to 1-1/2" port size

Shut-off & Lockout Valves 1/4 to 1-1/2 port size Section 16 Shut-off & Lockout Valves 1/4" to 1-1/2" port size Contents T72 Excelon Shut-off & Lockout Valves 1/4", 3/8" Port Sizes....................................ALE-16-2 T73 Excelon Shut-Off & Lockout

More information

3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve

3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve 3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve Type 6518 Type 6519 Type 6518/6519 can be combined with... Single or block mounting Suitable for outdoor and chemical atmospheres Suitable for

More information

VSO MAX HP High Flow Proportional Valve

VSO MAX HP High Flow Proportional Valve VSO MAX HP High Flow Proportional Valve Typical Applications Ventilators Insufflators Anesthesia Delivery & Monitors Pressure & Flow Control Mass Flow Control Product Specifications Physical Properties

More information

VP23, 3-way proportional pressure control valves Seat valve with μp-driven pressure control

VP23, 3-way proportional pressure control valves Seat valve with μp-driven pressure control VP, -way proportional pressure control valves > > Port size: G/... G/ > > All-digital control electronics > > Variable pressure control > > Optional actuation via fieldbus (separate datasheet on request)

More information

Mustang Series PRESSURE REDUCING CONTROL VALVE WITH PRESSURE SUSTAINING FEATURE. M115-2 (Globe) M1115-2 (Angle) Schematic. Standard Components

Mustang Series PRESSURE REDUCING CONTROL VALVE WITH PRESSURE SUSTAINING FEATURE. M115-2 (Globe) M1115-2 (Angle) Schematic. Standard Components Schematic Throttles to reduce high upstream pressure to constant lower downstream pressure Throttles to maintain minimum upstream pressure PRESSURE REDUCING CONTROL VALVE WITH PRESSURE SUSTAINING FEATURE

More information

3/2-way pneumatic cartridge solenoid valve

3/2-way pneumatic cartridge solenoid valve 3/2-way pneumatic cartridge solenoid valve Compact design with 11 mm width per station Orifices from 0.5 mm (9 bar) to 1.2 mm (1.5 bar) High durability and reliability Low power consumption, as well as

More information

VTA Series Pneumatic Three Way Air Switching Valves

VTA Series Pneumatic Three Way Air Switching Valves FANs 718, 977 Product Bulletin VTA Series Issue Date 0596 VTA Series Pneumatic Three Way Air Switching Valves The VTA Series Three Way Air Switching Valves are designed to switch the flow of air from onesupply

More information

167D Series Switching Valves

167D Series Switching Valves June 2011 167D Series Switching Valves P1185 P1184 167D TWO-WAY SWITCHING VALVE 167DA THREE-WAY SWITCHING VALVE Figure 1. 167D Series Switching Valves Introduction The 167D Series switching valves are

More information

Hydraulic Trouble Shooting

Hydraulic Trouble Shooting Hydraulic Trouble Shooting Hydraulic systems can be very simple, such as a hand pump pumping up a small hydraulic jack, or very complex, with several pumps, complex valving, accumulators, and many cylinders

More information

3/2-way Solenoid Valve, direct-acting, NC or NO

3/2-way Solenoid Valve, direct-acting, NC or NO 3/2-way Solenoid Valve, direct-acting, NC or NO Electrical connection cable plug, Form A With or without manual override as standard Threaded port and sub-base s Impulse optional Type 6014 can be combined

More information

Compressor Service & Maintenance Manual

Compressor Service & Maintenance Manual Compressor Service & Maintenance Manual C Series COMPRESSOR (D)C1103 (D)C1203 (D)C2106 (D)C2206 (D)C3210 Copyright 2006 DCI. All Rights Reserved. 92311, Rev. C, 08/13 1 C1000 Series Service & Maintenance

More information

AUTOMATIC CHANGEOVER MANIFOLD Series 915

AUTOMATIC CHANGEOVER MANIFOLD Series 915 AUTOMATIC CHANGEOVER MANIFOLD Series 915 FEATURES Fully automatic, simple, hassle-free operation No variance in delivery pressure Designed for ultra high purity gas service Built-in audio and visual alarm

More information

325C AIR COMPRESSOR KIT PART NO C AIR COMPRESSOR KIT PART NO C AIR COMPRESSOR KIT PART NO.

325C AIR COMPRESSOR KIT PART NO C AIR COMPRESSOR KIT PART NO C AIR COMPRESSOR KIT PART NO. 325C AIR COMPRESSOR KIT PART NO. 32530-32533 - 32534-32538 350C AIR COMPRESSOR KIT PART NO. 35030-35033 400C AIR COMPRESSOR KIT PART NO. 40040 450C AIR COMPRESSOR KIT PART NO. 45040 325C 350C 400C 450C

More information

Cylinder Speed Checker (Request for Special)

Cylinder Speed Checker (Request for Special) PRODUCT NAME Cylinder Speed Checker (Request for Special) For pneumatic cylinder with built-in magnet (round groove) MODEL / Series / Product Number IN574-95 (Speed + Cycle time + Count) Table of Contents

More information

Vacuum system components

Vacuum system components This is appropriate for high speed transfer such as electric part, compact precision part Vacuum system components VSN/VSNP Series VACUUM SYSTEM COMPONENTS SELVACS VSN/VSNP SERIES CC967A Appropriate for

More information

Differential Pressure Sensor

Differential Pressure Sensor 1 921 1921P01 Differential Pressure Sensor for neutral and mildly corrosive liquids and gases QBE64-DP4 Differential pressure sensor, suitable for gases or liquids, for the measurement of positive or negative

More information

Model E / E3 DN100 (4"), DN150 (6"), DN200 (8") Wet Alarm Valve with E2 Euro Stainless Steel Trim

Model E / E3 DN100 (4), DN150 (6), DN200 (8) Wet Alarm Valve with E2 Euro Stainless Steel Trim Information on Set-up, operation, service and maintenance Model E / E3 DN100 (4"), DN150 (6"), DN200 (8") Wet Alarm Valve with E2 Euro Stainless Steel Trim Model E/E3 with Stainless Steel Euro Trim Approval

More information

PRV-1PI Pilot operated pressure relief valve

PRV-1PI Pilot operated pressure relief valve Table of Content 1 Product Details... 2 1.1 Application... 2 1.2 Recommended Installation... 2 1.3 Function... 2 1.4 Features... 2 2 Technical Data... 3 3 Ordering Information... 3 3.1 Type Code... 3 4

More information

Powers Controls Free Energy Band TH 193 HC Heating/Cooling Room Thermostat

Powers Controls Free Energy Band TH 193 HC Heating/Cooling Room Thermostat Document No. 155-068P25 TH 193-4 Powers Controls Free Energy Band TH 193 HC Heating/Cooling Room Thermostat 50 60 70 80 70 TH0356R1 60 80 POWERS Description The TH 193 HC thermostats are proportional dual

More information