SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005
|
|
- Julie Sara Turner
- 7 years ago
- Views:
Transcription
1 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 MOVON 498-2, Geurmeo-ro, Pogok-eup, Cheoin-gu Yongin-si, Gyeonggi-do, SOUTH KOREA Authorized Representative: Danny Kim Phone: Website: ELECTRICAL (EMC) Valid To: December 31, 2016 Certificate Number: In recognition of the successful completion of the A2LA evaluation process, accreditation is granted to the laboratory listed above to perform the following automotive electromagnetic compatibility tests: Test Technology: Electrostatic Discharge (ESD) ISO (2001); CS Sections 7.1, 7.2; CS Sections 7.1, 7.2; ES-XW7T-1A278-AC (CI 280); GMW 3097 (2006, 2012) Section 3.6; SAE J ; DC (change A) Sections 10.1, 10.2; EMC-CS (CI 280); IEC ; EN ; RF Conducted Emissions CISPR 25 (2002, 2008) Sections 6.2, 6.3; CS Sections 5.1, 5.2; CS Sections 5.1, 5.2; ES-XW7T-1A278-AC (CE 420); GMW 3097 (2006, 2012) Section 3.3.2; DC (change A) Sections 6.2, 6.3; EMC-CS (CE 420, 421); TL965(2009); Radiated Emissions CISPR 25 (2002, 2008) Section 6.4; CS Section 5.3; CS Section 5.3; ES-XW7T-1A278-AC (RE 310); GMW 3097 (2006, 2012) Section 3.3.1; DC (change A) Section 6.4; EMC-CS (RE 310); (A2LA Cert. No ) Revised 11/16/2015 Page 1 of 6
2 Radiated (up to 6 GHz) and Conducted Emissions CISPR 22; EN Radiated Immunity IEC ; EN Electrical Fast Transient/Burst IEC ; EN Surge Immunity IEC ; EN Conducted Immunity IEC ; EN Power Frequency Magnetic Field Immunity IEC ; EN Voltage Dips, Short Interruptions, and Line Voltage Variations IEC ; EN Information Technology Equipment CISPR 24; EN Bulk Current Injection (BCI) Substitution Method Absorber-lined Shielded Enclosure (ALSE) With and Without Ground Plane Absorber-lined Shielded Enclosure RI Test Procedure Radar Pulse Only (ALSE) Bulk Current Injection (BCI) Closed Loop Method ISO (2005); CS Section 6.1; CS Section 6.1; ES-XW7T-1A278-AC (RI 112); GMW 3097 (2006, 2012) Section 3.4.1; ISO (2004); CS Section 6.2; CS Section 6.2; ES-XW7T-1A278-AC (RI 114); GMW 3097 (2006, 2012) Section 3.4.2; DC-11224; (change A) Sections 7.3, 7.4; EMC-CS (RI 114, RI 115); ISO (2004); ES-XW7T-1A278-AC (RI 114); GMW 3097 (2006, 2012) Section 3.4.2; EMC-CS (RI 114) ISO (2005); EMC-CS (RI 112); DC (change A) Section 7.2; Magnetic Field Immunity SAE J (1995); ISO (2007); DC (change A) Section 8.2; CS Section 6.3; CS Section 6.3; ES-XW7T-1A278-AC (RI 140); EMC-CS (RI 140); GMW 3097 (2006, 2012); (A2LA Cert. No ) Revised 11/16/2015 Page 2 of 6
3 Transient, Conducted Emissions (CE) and Conducted Immunity (CI): Transient, Conducted Emissions (CE) CI, Transients on Power Lines CI, Coupling to I/O other than Power Supply Lines CI, Direct Capacitor Coupling to Sensor Lines CI, 85V Direct Capacitor Coupling GMW 3097 (2006, 2012) Section 3.5.1; ISO ; GMW 3097 (2006, 2012) Section 3.5.2; ISO ; GMW 3097 (2006, 2012) Section 3.5.3; ISO ; GMW 3097 (2006, 2012) Section 3.5.4; ISO GMW 3097 (2006, 2012) Section 3.5.5; ISO Coupled Immunity ES-XW7T-1A278-AB/AC (RI 130, RI 150); EMC-CS Immunity from Continuous Disturbances: CI 210 Immunity from Transient Disturbances: CI 220 Immunity to Power Cycling: CI 230 Immunity to Voltage Offset: CI 250 Immunity to Voltage Dropout: CI 260 Immunity to Voltage Overstress: CI 270 Transient Immunity: Transient Disturbances Conducted along Supply Lines Transient Disturbances Conducted along I/O or Sensor Lines Operating Voltage Range IOD Voltage Ripple Supply Switch Deactivation ES-XW7T-1A278-AB/AC; EMC-CS DC (change A) Section 9.1; CS-11809; CS-11979; ISO DC (change A) Section 9.2; CS-11809; CS-11979; ISO DC Section 6.1; CS and CS Section DC Section 6.2; CS and CS Section DC Section 6.3; SAE J1113-2; CS and CS Section DC Section 7.1 (A2LA Cert. No ) Revised 11/16/2015 Page 3 of 6
4 Drop Out Dips Cranking Low Voltage Engine Cranking Cold Crank Engine Cranking Warn Crank Supply Voltage Ramp Up Supply Voltage Ramp Down Defective Regulation Jump Start Load Dump Reverse Supply Voltage Immunity to Short Circuit (Supply Lines) Immunity to Short Circuit (I/O Lines) Resistance to Overload Supply Voltage Offset Ground Reference Offset Operating and Voltage Stress for Motors Stall Test for Motors DC Section 7.2; CS and CS Section DC Section 7.3; CS and CS Section DC Section 7.4 CS and CS Section CS and CS Section DC Section 7.5; CS and CS Section DC Section 7.6; CS and CS Section DC Section 8.1; CS and CS Section DC Section 8.2; CS and CS Section DC Section 8.3; CS and CS Section DC Section 8.4; CS and CS Section DC Section 9.1; CS and CS Section DC Section 9.2; CS and CS Section DC Section 9.3 DC Section 9.4; CS and CS Section DC Section 9.5; CS and CS Section DC Section 10.1 DC Section 10.2; CS and CS Section (A2LA Cert. No ) Revised 11/16/2015 Page 4 of 6
5 Sneak Path Transient Over Voltage Electrical Load CS and CS Section CS and CS Section ISO ; ISO (2006) European Radio Test Standards ETSI EN ; ETSI EN ; ETSI EN ; ETSI EN ; ETSI EN ; ETSI EN ; ETSI EN Canadian Radio Test Standards Saudi Arabia Radio Test Standards RSS-GEN; RSS-102; RSS-210; RSS-247 CITC RI045; CITC RI054; CITC RI091; CITC RI102; CITC RI103; CITC RI104 Australia / New Zealand Radio Test Standards AS/NZS 4268; AS/NZS 4771 Japan Radio Test Standards ARIB STD-T66; ARIB STD-T67 (A2LA Cert. No ) Revised 11/16/2015 Page 5 of 6
6 Accredited Laboratory A2LA has accredited MOVON Yongin-si, Gyeonggi-do, South Korea for technical competence in the field of Electrical Testing This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2005 General requirements for the competence of testing and calibration laboratories. This accreditation demonstrates technical competence for a defined scope and the operation of a laboratory quality management system (refer to joint ISO-ILAC-IAF Communiqué dated 8 January 2009). Presented this 30 th day of March President & CEO For the Accreditation Council Certificate Number Valid to December 31, 2016 For the tests to which this accreditation applies, please refer to the laboratory s Electrical Scope of Accreditation.
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 YANFENG AUTOMOTIVE TRIM SYSTEMS CO. LTD. China Technical Center No. 1001 North Qinzhou Rd. Shanghai, China 200233 Shao Xiong (Test Center Manager/Local Authorized
More informationSCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 1
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 1 BUREAU VERITAS ADT (SHANGHAI) CORPORATION 2F, Building C, No. 1618. Yishan Road 201103 Shanghai, CHINA Ms. Mary Gu (Authorized Representative) Phone: 86 21
More informationSCOPE OF ACCREDITATION TO ISO/IEC 17025:2005
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 COMPLIANCE TESTING, LLC 1724 S Nevada Way Mesa, AZ 85204 Phone: 480 926 3100 Michael Schafer (Authorized Representative/President) Email michaels@compliancetesting.com
More informationCE MARK TECHNICAL FILE AS/NZS EMC CONSTRUCTION FILE
CE MARK TECHNICAL FILE AS/NZS EMC CONSTRUCTION FILE of Product Name Model Brand Memorex; Imation; TDK Life on Record Contains: 1. Declaration of Conformity 2. EN55022/CISPR 22, AS/NZS CISPR 22 EMI test
More informationTest Report. Prepared for: Technologic Systems, Inc. Model: TS-8820
Test Report Prepared for: Technologic Systems, Inc. Model: TS-8820 Description: Single Board Computer with Analog and Digital Inputs and Outputs, Relays, and RS-232/485 Ports To IEC 61000-6-1 (2005-03)
More informationRated Power(W) 8W 2. EG-LED0840-01 8W 3. EG-LED1027-01 10W
14713221 001 Seite 2 von 37 Page 2 of 37 Model List: No Model Rated Voltage(V) 1. EG-LED0827-01 Rated Power(W) 8W 2. EG-LED0840-01 8W 3. EG-LED1027-01 10W 4. EG-LED1040-01 AC 100-240V, 10W 5. EG-LED1027-02
More informationTEST REPORT EN 55014-2 (1997) +A1 (2001)
Page 1 of 23 TEST REPORT EN 55014-2 (1997) +A1 (2001) Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus Part 2: Immunity Report Reference No....
More informationLoad Dump Pulses According to Various Test Requirements: One Phenomenon Two Methods of Generation A Comparison
Load Dump Pulses According to Various Test Requirements: One Phenomenon Two Methods of Generation A Comparison Roland Spriessler 1, Markus Fuhrer 2, 1,2 EM Test, Sternenhofstrasse 15, CH-4153 Reinach (BL),
More informationFollowing are definitions for major parameters to consider when selecting a power line polarity protection diode for an automotive application.
Diode rectifiers are ideal solutions for automotive electronic power line protection and have several important parameters for these applications, including: Forward current, repetitive reverse voltage,
More informationDual Chamber Temporary External Pacemaker
5392 Dual Chamber Temporary External Pacemaker Electromagnetic Compatibility Declaration Caution: Federal law (USA) restricts this device to sale by or on the order of a physician. The following list includes
More informationTest Report #: 1981-3 Date: April 8, 2005
Test Report #: 1981-3 Date: April 8, 2005 CERTIFICATE #2316.01 Issued To: Bill Burks American Power Conversion 85 Rangeway Road North Billerica, MA 01862 USA 978-670-2440 Product Name/Description Model
More informationSTRATO LED Drivers 70W, Single output
Features STRATO switch mode driver technology is designed to generate one constant current output from a wide range AC input. The size and performance of these products make them the ideal choice for LED
More informationLAB 1 TECHNICAL DOC 3 IN ONE LAB DEVICE. Velleman Legen Heirweg 33 9890 Gavere Belgium
LAB 1 TECHNICAL DOC 3 IN ONE LAB DEVICE Velleman Legen Heirweg 33 9890 Gavere Belgium SPECIFICATIONS DIGITAL MULTIMETER 3 1/2 backlit LCD Automatic polarity indication DC voltage 200mV to 600V in 5 steps
More informationTM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector
Product datasheet Characteristics TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector Main Range of product Product or component type Range compatibility Enclosure material Bus
More informationSUGGESTED SPECIFICATION for Series 185 Service Entrance Rated Automatic Transfer Switches
SUGGESTED SPECIFICATION for Series 185 Service Entrance Rated Automatic Transfer Switches PART 1 GENERAL 1.01 Scope Optional Standby Power Generator Systems A. Furnish and install automatic transfer switches
More informationTeseq ESD Simulator Verification
Teseq ESD Simulator Verification Background Greg Senko, President Teseq Inc. North American division of Teseq Laboratory Technical Manager Edison NJ This presentation was first given in 2003 when lab was
More informationElectrical System Performance Requirements for Electrical and Electronic Components
DaimlerChrysler DC-10615 Joint Engineering Standard Date Published: 2003-05 Chrysler Category: L-2 Total No. of Pages (Including Annex): 22 Mercedes Benz Category: 22 Chrysler Contact: Terry M. North ADRESS
More informationSeries AMEPR30-AZ up to 2.5A AC-DC / DC-DC LED Driver / Converter
FEATURES: Click on Series name for product info on aimtec.com Models Single output Model Max Output Power (W) 1 AC-DC Constant Current or Constant Over temperature protection Voltage LED Driver Over current
More informationEMC & Wireless Certification
EMC & Wireless Certification Since 1872, TÜV Rheinland has been a world leader in compliance testing, guaranteeing customer satisfaction with its technical expertise and efficient delivery process. Since
More informationEMC Test for Compliance with EU EMC Directive 2004/108/EU
EMC Test for Compliance with EU EMC Directive 2004/108/EU Partial Test 12-12-2012 Standards Description EN 55022:2011 Information technology equipment - Radio disturbance characteristics - Limits and methods
More information(PREVIEW) Indian Standard COMMON SPECIFICATION FOR HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR STANDARDS
(PREVIEW) Indian Standard COMMON SPECIFICATION FOR HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR STANDARDS IS 12729:2004 IEC 60694(2002) 1.1 Scope This International Standard applies to a.c. switchgear and controlgear,
More informationIEC and CISPR Standards
IEC and CISPR Standards With thanks to Gideon Wiid, PhD student, and Paul van der Merwe EE Eng, 2 May, 2007 EMC Definition: Electromagnetic compatibility itself is defined as [1]: "the ability of an equipment
More informationA GENERIC AUTOMOTIVE (TIER1) EMC TEST STANDARD
A GENERIC AUTOMOTIVE (TIER1) EMC TEST STANDARD Martin O Hara The Automotive EMC Network, P.O. Box 3622, Newport Pagnell, MK16 0XT Abstract: The number of different EMC test standards available from the
More informationEC-Declaration of Conformity Annex
2006/95/EC is given by the compliance with the following European Standard(s). If not EN 61347-1: + A1:2011 EN 61347-2-1. A1:2006 + Corrigendum:2006 EN 61347-2-2: 2012 EN 61347-2-3: 2011 EN 61347-2-7:
More informationElectromagnetic Compatibility Specification For Electrical/Electronic Components and Subsystems
General Specification Electrical/Electronic FMC1278 Electromagnetic Compatibility Specification For Electrical/Electronic Components and Subsystems Foreword This engineering specification addresses Electromagnetic
More information40 Years of experience in EMC testing
40 Years of experience in EMC testing Your reference laboratory for tests of generation, propagation and reception of electromagnetic energy in civil, military and industrial applications. CESI has been
More informationANSI Watthour Meter Testing & Certification Programs
ANSI Watthour Meter Testing & Certification Programs By Jim Reed Manager, Meter Accuracy Lab and Manasi Bhandiwad Manager, EMC Lab Laboratories, Inc. First in Certification Accreditations and Recognitions
More informationGrounding Demystified
Grounding Demystified 3-1 Importance Of Grounding Techniques 45 40 35 30 25 20 15 10 5 0 Grounding 42% Case 22% Cable 18% Percent Used Filter 12% PCB 6% Grounding 42% Case Shield 22% Cable Shielding 18%
More informationAnalog signal converters CC-E I/I Current / current isolators
ata sheet Analog signal converters CC-E I/I Current / current isolators The CC-E I/I is an isolator for the electrical isolation of current signals without auxiliary supply. It allows the isolation between
More informationCOMMON REGULATORY OBJECTIVES FOR WIRELESS LOCAL AREA NETWORK (WLAN) EQUIPMENT PART 2 SPECIFIC ASPECTS OF WLAN EQUIPMENT
COMMON REGULATORY OBJECTIVES FOR WIRELESS LOCAL AREA NETWORK (WLAN) EQUIPMENT PART 2 SPECIFIC ASPECTS OF WLAN EQUIPMENT 1. SCOPE This Common Regulatory Objective, CRO, is applicable to Wireless Local Area
More informationTEST REPORT Rapporto di prova EMC N 060406. Test facility site: via L. da Vinci, 92, Caravaggio (BG), Italy Sede laboratorio
TEST REPORT Rapporto di prova EMC N 060406 EUT: Organic Carbon Analyzer Analiuzzatore Carbonio Organico Model: TOCMETER Serial N : TM602 Client: TRE-ESSE s.r.l. Cliente Piazzale Europa 8 16036 Recco (GE),
More informationAKKREDITOITU TESTAUSLABORATORIO ACCREDITED TESTING LABORATORY MICROSOFT MOBILE OY TCC MICROSOFT
T117/M51/2016 Liite 1 / Appendix 1 Sivu / Page 1(20) AKKREDITOITU TESTAUSLABORATORIO ACCREDITED TESTING LABORATORY MICROSOFT MOBILE OY TCC MICROSOFT Tunnus Code Laboratorio Laboratory Osoite Address www
More informationEspotel Test Laboratory Services. November 20, 2014
Espotel Test Laboratory Services November 20, 2014 Espotel Laboratory Services EMC, ESD, RF testing EMC chamber for radiated emissions and immunity testing Radiated interoperability for LTE, GSM/3G, WLAN
More informationEMC STANDARDS STANDARDS AND STANDARD MAKING BODIES. International. International Electrotechnical Commission (IEC) http://www.iec.
EMC STANDARDS The EMC standards that a particular electronic product must meet depend on the product application (commercial or military) and the country in which the product is to be used. These EMC regulatory
More informationBulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller
Overview/Modes of Operation Bulletin 150 Smart Motor Controller The SMC-3 is a compact, simple to use, solid-state motor controller designed to operate 3-phase motors. It features a built-in overload relay
More informationGain energy insight and control with PowerLogic. PowerLogic EGX300 integrated gateway-server
Gain energy insight and control with PowerLogic PowerLogic EGX300 integrated gateway-server Plug into your energy usage with a simple mouse click The PowerLogic EGX300 is an integrated gateway-server that
More informationFoxboro Evo Process Automation System
Foxboro Evo Process Automation System Product Specifications PSS 31H-2Z32 FBM232 Field Device System Integrator Module, 10/100 Mbps Ethernet, Single The FBM232 Field Device System Integrator (FDSI) module
More informationElectromagnetic Compatibility and International Regulatory Approvals
Electromagnetic Compatibility and International Regulatory Approvals Most countries have now implemented strict regulations regarding Electromagnetic Compatibility (EMC) for electronic devices. This paper
More informationSCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994. ALLTITE, INC. 1600 Murdock, Wichita, KS 67214 Bruce Demaree Phone: 800 498 6721
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 ALLTITE, INC. 1600 Murdock, Wichita, KS 67214 Bruce Demaree Phone: 800 498 6721 CALIBRATION Valid To: September 30, 2016 Certificate
More informationAn extended EMC study of an electrical powertrain for transportation systems
European Association for the Development of Renewable Energies, Environment and Power Quality (EA4EPQ) International Conference on Renewable Energies and Power Quality (ICREPQ 12) Santiago de Compostela
More informationEMC TEST REPORT For. Shenzhen Homelux Security Equipment Co., Ltd. Auto Dialer. Model No.: HX-GD20
EMC TEST REPORT For Shenzhen Homelux Security Equipment Co., Ltd Auto Dialer Model No.: HX-GD20 Prepared for : Shenzhen Homelux Security Equipment Co., Ltd Address : 4 th Floor, Building 5, Jiademaluan
More informationCAT ATC POWER BREAKER & POWER CASE SWITCH AUTOMATIC TRANSFER SWITCH
CAT ATC POWER BREAKER & POWER CASE SWITCH AUTOMATIC TRANSFER SWITCH Cat transfer switches are designed for a variety of standby power applications. They provide flexibility, reliability and value in a
More informationPatient Transport. with the Automated Impella Controller
Patient Transport with the Automated Impella Controller TABLE OF CONTENTS PURPOSE OF THESE INSTRUCTIONS... 2 INDICATION FOR USE... 2 FAA ADVISORY... 2 ABOUT THE IMPELLA SYSTEM... 3 PATIENT TRANSPORT WITH
More informationWhite Paper: Electrical Ground Rules
Acromag, Incorporated 30765 S Wixom Rd, Wixom, MI 48393 USA Tel: 248-295-0880 Fax: 248-624-9234 www.acromag.com White Paper: Electrical Ground Rules Best Practices for Grounding Your Electrical Equipment
More informationWhat do SAE standards offer the Automotive Electronics industry?
What do SAE standards offer the Automotive Electronics industry? Just about everything. Volume 2, 2009 SAE standards stand ready to serve industry s growing need for globally harmonized standards solutions.
More informationAN96-07. Surging Ideas TVS Diode Application Note PROTECTION PRODUCTS. TRANSIENT IMMUNITY STANDARDS: IEC 61000-4-x
TRANSIENT IMMUNITY STANDARDS: IEC 61000-4-x On January 1, 1996, exports into Europe began facing some tough transient immunity standards. The International Electrotechnical Commission (IEC), a worldwide
More informationDigital Controllers ACTUATOR COMPATABILITY
Product Specification 36502B DESCRIPTION APECS DPG-21XX-00X Digital Controllers The DPG-21XX-00X digital controller is used primarily to govern diesel or gas fueled engines of generator sets. This microprocessor-based,
More informationTechnical Article MS-2443
. MS-2443 Safeguard Your RS-485 Communication Networks from Harmful EMC Events by James Scanlon, Senior Evaluation Engineer, Analog Devices, Inc., and Koenraad Rutgers, Senior Field Applications Engineer,
More informationHuawei NE5000E 400Gbps Flexible Line Processing Unit
Huawei NE5000E 400Gbps Flexible Line Processing Unit Huawei NE5000E 400Gbps Flexible Line Processing Unit Overview The Huawei NetEngine5000E router (NE5000E) is a high-end IP core network router. It is
More informationDeclaration of Conformity.
Declaration of Conformity. Type of equipment: Brand Name /Trade Mark: Type designation /model: Applicant: PTZ CAMERA SAMSUNG SCP2371HP SAMSUNG TECHWIN CO., LTD. In accordance with the following Directives:
More informationAN-3 SEVEN KEY CONSIDERATIONS BEFORE YOU START YOUR SLIC OR FXS PHONE LINE INTERFACE DESIGN
AN-3 SEVEN KEY CONSIDERATIONS BEFORE YOU START YOUR SLIC OR FXS PHONE LINE INTERFACE DESIGN By Joe Randolph Introduction The conventional 2-wire analog phone line that telephone companies provide to residential
More informationWaveguide Access Point WGA631. Product Guide
Waveguide Access Point Product Guide Waveguide Access Point Contents 1. Description............................ 3 2. Application............................ 3 3. Technical data... 4 4. Physical interfaces......................
More informationRack mounted telephone- and leased line modem for industrial applications
Rack mounted telephone- and leased line modem for industrial applications TR-6 Rack modem for industrial PSTNand /-wire leased line applications The TR-6 is an analogue V. 9 -rack PSTN modem as well as
More informationThe impact of the New EMC Directive 2004/108/EC
The impact of the New EMC Directive 2004/108/EC Presentation by Damon High Presentation Overview Brief overview of Electromagnetic Interference and Electromagnetic Compatibility EMC Directive and UK Legislation
More informationWIRELESS MAGNETIC CONTACT
WIRELESS MAGNETIC CONTACT The magnetic contact wireless MAG HCS is a sensor able to detect opening or closing doors or windows and transmits via radio a alarm signal. It is composed of two distinct elements:
More informationElectromagnetic Compatibility Considerations for Switching Power Supplies
Electromagnetic Compatibility Considerations Characterization of the EMI problem requires understanding the interference source Switching power supplies generate Electromagnetic Interference (EMI) by virtue
More informationIEC 1000-4-2 ESD Immunity and Transient Current Capability for the SP72X Series Protection Arrays
IEC 00-4-2 ESD Immunity and Transient Current Capability for the SP72X Series Protection Arrays Application Note July 1999 AN9612.2 Author: Wayne Austin The SP720, SP721, SP723, and SP724 are protection
More informationAMP 200N1 LOW FREQUENCY SIGNAL SOURCE DC (0HZ) TO 250KHZ, 800W
AMP 200N1 LOW FREQUENCY SIGNAL SOURCE DC (0HZ) TO 250KHZ, 800W SELON LES NORMES SUIVANTES... > Chrysler CS-11809 (2009) > Chrysler CS-11979 > Chrysler DC-11224 Rev.A > DaimlerChrysler DC-10614 > DaimlerChrysler
More informationPD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description
Photoelectrics, Background Suppression reflective with IR light Main features Description The PD30ET... stainless steel sensors are built with high-quality materials and designed for harsh environments.
More informationDUAL%CHANNEL BROADBAND%LINEAR%AMPLIFIER Model&A800D
ELECTRONICS AB DUAL%CHANNEL BROADBAND%LINEAR%AMPLIFIER Model&A800D & HIGH&VOLTAGE& FIXED&GAIN& BROADBAND & 800Vpp&60mA& 100x& DC&to&ca&200&kHz & LOW&OUTPUT&IMPEDANCE& HIGH&SLEW&RATE &
More informationPE310G4BPi40-T Quad port Copper 10 Gigabit Ethernet PCI Express Bypass Server Intel based
PE310G4BPi40-T Quad port Copper 10 Gigabit Ethernet PCI Express Bypass Server Intel based Description Silicom s quad port Copper 10 Gigabit Ethernet Bypass server adapter is a PCI-Express X8 network interface
More information30 In Compliance October 2014 www.incompliancemag.com
30 In Compliance October 2014 www.incompliancemag.com Medical Devices in a Wireless World BY IVAYLO TANKOV While wireless technology is now an integral component of a wide variety of manufactured products,
More informationElectronic timer CT-VBS.17+18 OFF-delayed without auxiliary voltage, for DC contactors Data sheet
Characteristics Single-function OFF-delay timer for DC contactors, without auxiliary voltage Width.5 mm CDC 5 6 F3 Approvals A culus E CCC CT-VBS a Circuit diagram b Marker label Marks a CE b C-Tick Order
More informationC-Bus. Single Zone Thermostat. 5070THB Series. Installation Instructions REGISTERED DESIGN REGISTERED PATENT
C-Bus Single Zone Thermostat 5070THB Series REGISTERED DESIGN REGISTERED PATENT Clipsal is a registered trademark of Clipsal Australia Pty Ltd ABN 27 007 873 529. Copyright Clipsal Australia Pty Ltd 2008.
More informationTemperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)
Data sheet Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection) The temperature monitoring relays CM-TCS monitor overtemperature,
More informationEMC Basics. Speaker : Alain Lafuente. Alain.lafuente@we-online.com
EMC Basics Speaker : lain Lafuente lain.lafuente@we-online.com WHT IS EMC? 2 CE Marking With the formation of the single European market, standardization was required to remove technical barriers to trade.
More informationPanashield, Inc. Facility Solutions For Global Electromagnetic Compatibility
Panashield, Inc. Facility Solutions For Global Electromagnetic Compatibility Absorber Technologies and Its Impact on Anechoic / Semi Anechoic Chambers Peggy Girard November 2012 Discussion Points Brief
More informationThree-phase monitoring relay CM-PFE
Data sheet Three-phase monitoring relay CM-PFE The CM-PFE is a three-phase monitoring relay that monitors the phase parameter phase sequence and phase failure in three-phase mains. 2CDC 251 005 S0012 Characteristics
More informationAutomotive Component EMC Testing: CISPR 25, ISO 11452-2 and Equivalent Standards
Automotive Component EMC Testing: CISPR 25, ISO 11452-2 and Equivalent Standards Vicente Rodriguez ETS-LindgrenL.P. Email:Vince.Rodriguez@ets-lindgren.com Abstract: This paper presents compiles some information
More informationSCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSLI Z540-1-1994
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSLI Z540-1-1994 TEKTRONIX, INC. 13725 SW Karl Braun Drive Beaverton, OR 97077 Andrew Mumford Phone: 503 627 2476 CALIBRATION Valid to: June 30, 2018
More informationCisco ASR 9001-S Router
Data Sheet Cisco ASR 9001-S Router Product Overview Part of the Cisco ASR 9000 Series, the Cisco ASR 9001-S Router (Figure 1) is a compact, high-capacity provider edge router that delivers 60 Gbps of nonblocking,
More informationEMC-conform development of a Tablet-PC
EMC-conform development of a Tablet-PC January 21, 2014 Johannes Biner Electrosuisse Montena EMC Bernstrasste 93 CH - 3006 Bern Tel. +41 79 256 21 55 Johannes.biner@montenaemc.ch www.montenaemc.ch Programm
More informationOperating Manual UWAPS-TINY Series
Operating Manual UWAPS-TINY Series Powecon Oy WWW.POWECON.FI 1/9 Table of content 1 Warranty...3 2 Safety information...3 3 Abbreviations and terminology...3 4 List of appendices...4 5 Introduction...4
More informationCisco Unified IP Phone Power Injector
Data Sheet Cisco Unified IP Phone Power Injector The Cisco Unified IP Phone Power Injector (Figure 1) increases the deployment flexibility of Cisco Unified IP phones by providing an alternative powering
More informationIEEE Electromagnetic Compatibility Standards (Active & Archive) Collection: VuSpec
IEEE Electromagnetic Compatibility Standards (Active & Archive) Collection: VuSpec This value-packed VuSpec CD-ROM represents the most complete resource available for professional engineers looking for
More informationEPL225 Series. 225 Watts. www.xppower.com. AC-DC Power Supplies. Models & Ratings. Summary
225 Watts 50 W Convection/ 225 W Forced-cooled Ratings 2 by 4 Footprint Low.26 Profile 2 V Fan Output High Efficiency, up to 95% ITE & Medical pprovals High Power Density Less than 0.5 W No Load Input
More informationAND8229/D. An Introduction to Transient Voltage Suppression Devices APPLICATION NOTE
An Introduction to Transient Voltage Suppression Devices Prepared by: Jim Lepkowski ON Semiconductor APPLICATION NOTE INTRODUCTION Transient Voltage Suppression (TVS) protection devices such as shielded
More informationMEDICAL DEVICES : Guidance document
EUROPEAN COMMISSION DG ENTERPRISE Directorate G Unit 4 - Pressure Equipment, Medical Devices, Metrology MEDICAL DEVICES : Guidance document MEDDEV 2. 2/1 Rev1 February 1998 GUIDELINES RELATING TO THE APPLICATION
More informationAVR040: EMC Design Considerations. 8-bit Microcontrollers. Application Note PRELIMINARY. Scope. 1 Introduction
AVR040: EMC Design Considerations Scope This application note covers the most common EMC problems designers encounter when using microcontrollers. It will briefly discuss the various phenomena. The reference
More informationCisco ubr7200-npe-g2 Network Processing Engine
Cisco ubr7200-npe-g2 Network Processing Engine Product Overview With the introduction of the ubr7200-npe-g2 Network Processing Engine, service providers can now take advantage of the enhanced performance
More informationCommission communication in the framework of the implementation of the Council Directive 89/336/EEC (2002/C 190/03)
10.8.2002 Official Journal of the European Communities C 190/5 Commission communication in the framework of the implementation of the Council Directive 89/336/EEC (2002/C 190/03) (Text with EEA relevance)
More informationAnnex of the certificate (Page 1/18) Accreditation Scope
Annex of the certificate (Page 1/18) As a Testing Laboratory Accreditation Nr: Address:Organize Sanayi Bölgesi Büyük Selçuklu Blv. No:2 Sincan 06930 ANKARA / TÜRKİYE Phone : 0 312 267 32 43 Fax : 0 312
More informationABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.
1SR 430 824 F9300 Features Monitoring of three-phase mains for phase sequence and failure Powered by the measuring circuit 2 c/o (SPDT) contacts 1 LED for status indication Approvals R: yellow LED - relay
More informationINTERNATIONAL STANDARD
INTERNATIONAL STANDARD IEC 61131-2 Third edition 2007-07 Programmable controllers Part 2: Equipment requirements and tests Commission Electrotechnique Internationale International Electrotechnical Commission
More informationCommunicate and view data from meters with one simple device
Communicate and view data from meters with one simple device PowerLogic EGX300 integrated gateway-server Web Monitoring Communications Plug and Play Plug into your energy usage with a simple mouse click
More informationUSB-to-Data Highway Plus Cable
Installation Instructions USB-to-Data Highway Plus Cable Catalog Number 1784-U2DHP Topic Page Important User Information 2 Environment and Enclosure 3 Install the Cable 5 Configure the DH+ Node Address
More informationEvaluating Cell Phone and Personal Communications Equipment and their EMC Effects on Automotive Audio and In-Cabin Modules
Evaluating Cell Phone and Personal Communications Equipment and their EMC Effects on Automotive Audio and In-Cabin Modules Craig W. Fanning Elite Electronic Engineering, Inc. 1516 Centre Circle Downers
More informationSingle-phase (220...240 V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable
Features 70.11 70.31 70.41 Electronic voltage monitoring relays for single and three-phase applications Multifunctional types, providing the flexibility of monitoring Undervoltage, Overvoltage, Window
More informationElectronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact
Data sheet Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact The CT-AHD.12 is an electronic time relay with OFF-delay. It is from the CT-D range. With their MDRC profile and a width of only
More informationStandard: EN 61000-4-2 :1995, EN 61000-4-3 :1996, ENV 50204 :1993, & EN 61000-4-4 :1995 Solid State Energy Meter
Standard: EN 61000-4-2 :1995, EN 61000-4-3 :1996, ENV 50204 :1993, & EN 61000-4-4 :1995 Model: Solid State Energy Meter Prepared for: Analog Devices, Inc. 804 Woburn Street Wilmington, MA 01887 Date of
More information1788 Linking Device Specifications
Technical Data 1788 Linking Device Specifications Catalog Numbers 1788-EN2DNROM, 1788-EN2DNR, 1788-EN2FFR, 1788-EN2PAR, 1788-CN2DN, 1788-CN2FFR, 1788-CN2PAR, 1788-FBJB4R, 1788-FBJB6 Topic Page 1788-EN2DNR
More informationA Practical Guide to Dielectric Testing
Chroma Systems Solutions, Inc. A Practical Guide to Dielectric Testing 19032 Series Electrical Safety Analyzer & 19050 Series Hipot Tester AC/DC/IR/SCAN Keywords: Dielectric tests, insulation resistance
More informationEMC Standards: Standards of good EMC engineering
Electromagnetic Compatibility (EMC) IEEE Definition Origin, control, and measurement of electromagnetic effects on electronic and biologic systems. IEEE EMC Society Areas of Interest EMC Standards: Standards
More informationBulletin 150 SMC Flex Smart Motor Controller Specifications
Specifications Specifications Standard Features Optional Features Installation Setup Communications Power Wiring Control Wiring Keypad Software Starting and Stopping Modes Protection and Diagnostics Metering
More informationQuality System Overview
Quality System Overview Agenda Agenda ISO Registration Flow Down Requirements Governance Contract Supplier Quality Performance Inspection Quality Assurance : Project Verification Compliance CE Marking
More informationEMC Supplemental Information and Alternative Component Requirements
DaimlerChrysler DC-11225 Joint Engineering Standard Date Published: 2006-11 Chrysler Category: L-2 Total No. of Pages (Including Annex): 39 Mercedes-Benz Category: 22 Chrysler Author: Terry M. North ADRESS
More informationHEOL-N103-OBD, GPS/GPRS Tracking Module with On Board Diagnostic
HEOL-N103-OBD, GPS/GPRS Tracking Module with On Board Diagnostic Heol fleet tracking system GPS N103 -OBD GPRS FTS Software Internet Main office - Control room Other office The specifications in this document
More informationPower Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1
Power Supply Unit, Primary Switched, Narrow Design MINI POWER provides: Extra narrow design with widths of 22.5 mm, 45 mm, and 67.5 mm (0.886, 1.772, and 2.657 in.) Global use due to a wide-range input
More informationAXIS 291 1U Video Server Rack Installation Guide
AXIS 291 1U Video Server Rack Installation Guide About This Document This document describes how to install Axis blade video servers in the AXIS 291 1U Video Server Rack. Updated versions of this document
More informationEN 301 489-17 v1.2.1 TEST REPORT FOR. 802.11ag/Draft 802.11n WLAN PCI-E Mini Card MODEL NUMBER: BCM94322MC REPORT NUMBER: 07U11529-5
EN 301 489-17 v1.2.1 TEST REPORT FOR 802.11ag/Draft 802.11n WLAN PCI-E Mini Card MODEL NUMBER: BCM94322MC REPORT NUMBER: 07U11529-5 ISSUE DATE: JANUARY 29, 2008 Prepared for BROADCOM CORPORATION 190 MATHILDA
More information