SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

Size: px
Start display at page:

Download "SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005"

Transcription

1 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 MOVON 498-2, Geurmeo-ro, Pogok-eup, Cheoin-gu Yongin-si, Gyeonggi-do, SOUTH KOREA Authorized Representative: Danny Kim Phone: Website: ELECTRICAL (EMC) Valid To: December 31, 2016 Certificate Number: In recognition of the successful completion of the A2LA evaluation process, accreditation is granted to the laboratory listed above to perform the following automotive electromagnetic compatibility tests: Test Technology: Electrostatic Discharge (ESD) ISO (2001); CS Sections 7.1, 7.2; CS Sections 7.1, 7.2; ES-XW7T-1A278-AC (CI 280); GMW 3097 (2006, 2012) Section 3.6; SAE J ; DC (change A) Sections 10.1, 10.2; EMC-CS (CI 280); IEC ; EN ; RF Conducted Emissions CISPR 25 (2002, 2008) Sections 6.2, 6.3; CS Sections 5.1, 5.2; CS Sections 5.1, 5.2; ES-XW7T-1A278-AC (CE 420); GMW 3097 (2006, 2012) Section 3.3.2; DC (change A) Sections 6.2, 6.3; EMC-CS (CE 420, 421); TL965(2009); Radiated Emissions CISPR 25 (2002, 2008) Section 6.4; CS Section 5.3; CS Section 5.3; ES-XW7T-1A278-AC (RE 310); GMW 3097 (2006, 2012) Section 3.3.1; DC (change A) Section 6.4; EMC-CS (RE 310); (A2LA Cert. No ) Revised 11/16/2015 Page 1 of 6

2 Radiated (up to 6 GHz) and Conducted Emissions CISPR 22; EN Radiated Immunity IEC ; EN Electrical Fast Transient/Burst IEC ; EN Surge Immunity IEC ; EN Conducted Immunity IEC ; EN Power Frequency Magnetic Field Immunity IEC ; EN Voltage Dips, Short Interruptions, and Line Voltage Variations IEC ; EN Information Technology Equipment CISPR 24; EN Bulk Current Injection (BCI) Substitution Method Absorber-lined Shielded Enclosure (ALSE) With and Without Ground Plane Absorber-lined Shielded Enclosure RI Test Procedure Radar Pulse Only (ALSE) Bulk Current Injection (BCI) Closed Loop Method ISO (2005); CS Section 6.1; CS Section 6.1; ES-XW7T-1A278-AC (RI 112); GMW 3097 (2006, 2012) Section 3.4.1; ISO (2004); CS Section 6.2; CS Section 6.2; ES-XW7T-1A278-AC (RI 114); GMW 3097 (2006, 2012) Section 3.4.2; DC-11224; (change A) Sections 7.3, 7.4; EMC-CS (RI 114, RI 115); ISO (2004); ES-XW7T-1A278-AC (RI 114); GMW 3097 (2006, 2012) Section 3.4.2; EMC-CS (RI 114) ISO (2005); EMC-CS (RI 112); DC (change A) Section 7.2; Magnetic Field Immunity SAE J (1995); ISO (2007); DC (change A) Section 8.2; CS Section 6.3; CS Section 6.3; ES-XW7T-1A278-AC (RI 140); EMC-CS (RI 140); GMW 3097 (2006, 2012); (A2LA Cert. No ) Revised 11/16/2015 Page 2 of 6

3 Transient, Conducted Emissions (CE) and Conducted Immunity (CI): Transient, Conducted Emissions (CE) CI, Transients on Power Lines CI, Coupling to I/O other than Power Supply Lines CI, Direct Capacitor Coupling to Sensor Lines CI, 85V Direct Capacitor Coupling GMW 3097 (2006, 2012) Section 3.5.1; ISO ; GMW 3097 (2006, 2012) Section 3.5.2; ISO ; GMW 3097 (2006, 2012) Section 3.5.3; ISO ; GMW 3097 (2006, 2012) Section 3.5.4; ISO GMW 3097 (2006, 2012) Section 3.5.5; ISO Coupled Immunity ES-XW7T-1A278-AB/AC (RI 130, RI 150); EMC-CS Immunity from Continuous Disturbances: CI 210 Immunity from Transient Disturbances: CI 220 Immunity to Power Cycling: CI 230 Immunity to Voltage Offset: CI 250 Immunity to Voltage Dropout: CI 260 Immunity to Voltage Overstress: CI 270 Transient Immunity: Transient Disturbances Conducted along Supply Lines Transient Disturbances Conducted along I/O or Sensor Lines Operating Voltage Range IOD Voltage Ripple Supply Switch Deactivation ES-XW7T-1A278-AB/AC; EMC-CS DC (change A) Section 9.1; CS-11809; CS-11979; ISO DC (change A) Section 9.2; CS-11809; CS-11979; ISO DC Section 6.1; CS and CS Section DC Section 6.2; CS and CS Section DC Section 6.3; SAE J1113-2; CS and CS Section DC Section 7.1 (A2LA Cert. No ) Revised 11/16/2015 Page 3 of 6

4 Drop Out Dips Cranking Low Voltage Engine Cranking Cold Crank Engine Cranking Warn Crank Supply Voltage Ramp Up Supply Voltage Ramp Down Defective Regulation Jump Start Load Dump Reverse Supply Voltage Immunity to Short Circuit (Supply Lines) Immunity to Short Circuit (I/O Lines) Resistance to Overload Supply Voltage Offset Ground Reference Offset Operating and Voltage Stress for Motors Stall Test for Motors DC Section 7.2; CS and CS Section DC Section 7.3; CS and CS Section DC Section 7.4 CS and CS Section CS and CS Section DC Section 7.5; CS and CS Section DC Section 7.6; CS and CS Section DC Section 8.1; CS and CS Section DC Section 8.2; CS and CS Section DC Section 8.3; CS and CS Section DC Section 8.4; CS and CS Section DC Section 9.1; CS and CS Section DC Section 9.2; CS and CS Section DC Section 9.3 DC Section 9.4; CS and CS Section DC Section 9.5; CS and CS Section DC Section 10.1 DC Section 10.2; CS and CS Section (A2LA Cert. No ) Revised 11/16/2015 Page 4 of 6

5 Sneak Path Transient Over Voltage Electrical Load CS and CS Section CS and CS Section ISO ; ISO (2006) European Radio Test Standards ETSI EN ; ETSI EN ; ETSI EN ; ETSI EN ; ETSI EN ; ETSI EN ; ETSI EN Canadian Radio Test Standards Saudi Arabia Radio Test Standards RSS-GEN; RSS-102; RSS-210; RSS-247 CITC RI045; CITC RI054; CITC RI091; CITC RI102; CITC RI103; CITC RI104 Australia / New Zealand Radio Test Standards AS/NZS 4268; AS/NZS 4771 Japan Radio Test Standards ARIB STD-T66; ARIB STD-T67 (A2LA Cert. No ) Revised 11/16/2015 Page 5 of 6

6 Accredited Laboratory A2LA has accredited MOVON Yongin-si, Gyeonggi-do, South Korea for technical competence in the field of Electrical Testing This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2005 General requirements for the competence of testing and calibration laboratories. This accreditation demonstrates technical competence for a defined scope and the operation of a laboratory quality management system (refer to joint ISO-ILAC-IAF Communiqué dated 8 January 2009). Presented this 30 th day of March President & CEO For the Accreditation Council Certificate Number Valid to December 31, 2016 For the tests to which this accreditation applies, please refer to the laboratory s Electrical Scope of Accreditation.

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 YANFENG AUTOMOTIVE TRIM SYSTEMS CO. LTD. China Technical Center No. 1001 North Qinzhou Rd. Shanghai, China 200233 Shao Xiong (Test Center Manager/Local Authorized

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 1

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 1 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 1 BUREAU VERITAS ADT (SHANGHAI) CORPORATION 2F, Building C, No. 1618. Yishan Road 201103 Shanghai, CHINA Ms. Mary Gu (Authorized Representative) Phone: 86 21

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 COMPLIANCE TESTING, LLC 1724 S Nevada Way Mesa, AZ 85204 Phone: 480 926 3100 Michael Schafer (Authorized Representative/President) Email michaels@compliancetesting.com

More information

CE MARK TECHNICAL FILE AS/NZS EMC CONSTRUCTION FILE

CE MARK TECHNICAL FILE AS/NZS EMC CONSTRUCTION FILE CE MARK TECHNICAL FILE AS/NZS EMC CONSTRUCTION FILE of Product Name Model Brand Memorex; Imation; TDK Life on Record Contains: 1. Declaration of Conformity 2. EN55022/CISPR 22, AS/NZS CISPR 22 EMI test

More information

Test Report. Prepared for: Technologic Systems, Inc. Model: TS-8820

Test Report. Prepared for: Technologic Systems, Inc. Model: TS-8820 Test Report Prepared for: Technologic Systems, Inc. Model: TS-8820 Description: Single Board Computer with Analog and Digital Inputs and Outputs, Relays, and RS-232/485 Ports To IEC 61000-6-1 (2005-03)

More information

Rated Power(W) 8W 2. EG-LED0840-01 8W 3. EG-LED1027-01 10W

Rated Power(W) 8W 2. EG-LED0840-01 8W 3. EG-LED1027-01 10W 14713221 001 Seite 2 von 37 Page 2 of 37 Model List: No Model Rated Voltage(V) 1. EG-LED0827-01 Rated Power(W) 8W 2. EG-LED0840-01 8W 3. EG-LED1027-01 10W 4. EG-LED1040-01 AC 100-240V, 10W 5. EG-LED1027-02

More information

TEST REPORT EN 55014-2 (1997) +A1 (2001)

TEST REPORT EN 55014-2 (1997) +A1 (2001) Page 1 of 23 TEST REPORT EN 55014-2 (1997) +A1 (2001) Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus Part 2: Immunity Report Reference No....

More information

Load Dump Pulses According to Various Test Requirements: One Phenomenon Two Methods of Generation A Comparison

Load Dump Pulses According to Various Test Requirements: One Phenomenon Two Methods of Generation A Comparison Load Dump Pulses According to Various Test Requirements: One Phenomenon Two Methods of Generation A Comparison Roland Spriessler 1, Markus Fuhrer 2, 1,2 EM Test, Sternenhofstrasse 15, CH-4153 Reinach (BL),

More information

Following are definitions for major parameters to consider when selecting a power line polarity protection diode for an automotive application.

Following are definitions for major parameters to consider when selecting a power line polarity protection diode for an automotive application. Diode rectifiers are ideal solutions for automotive electronic power line protection and have several important parameters for these applications, including: Forward current, repetitive reverse voltage,

More information

Dual Chamber Temporary External Pacemaker

Dual Chamber Temporary External Pacemaker 5392 Dual Chamber Temporary External Pacemaker Electromagnetic Compatibility Declaration Caution: Federal law (USA) restricts this device to sale by or on the order of a physician. The following list includes

More information

Test Report #: 1981-3 Date: April 8, 2005

Test Report #: 1981-3 Date: April 8, 2005 Test Report #: 1981-3 Date: April 8, 2005 CERTIFICATE #2316.01 Issued To: Bill Burks American Power Conversion 85 Rangeway Road North Billerica, MA 01862 USA 978-670-2440 Product Name/Description Model

More information

STRATO LED Drivers 70W, Single output

STRATO LED Drivers 70W, Single output Features STRATO switch mode driver technology is designed to generate one constant current output from a wide range AC input. The size and performance of these products make them the ideal choice for LED

More information

LAB 1 TECHNICAL DOC 3 IN ONE LAB DEVICE. Velleman Legen Heirweg 33 9890 Gavere Belgium

LAB 1 TECHNICAL DOC 3 IN ONE LAB DEVICE. Velleman Legen Heirweg 33 9890 Gavere Belgium LAB 1 TECHNICAL DOC 3 IN ONE LAB DEVICE Velleman Legen Heirweg 33 9890 Gavere Belgium SPECIFICATIONS DIGITAL MULTIMETER 3 1/2 backlit LCD Automatic polarity indication DC voltage 200mV to 600V in 5 steps

More information

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector Product datasheet Characteristics TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector Main Range of product Product or component type Range compatibility Enclosure material Bus

More information

SUGGESTED SPECIFICATION for Series 185 Service Entrance Rated Automatic Transfer Switches

SUGGESTED SPECIFICATION for Series 185 Service Entrance Rated Automatic Transfer Switches SUGGESTED SPECIFICATION for Series 185 Service Entrance Rated Automatic Transfer Switches PART 1 GENERAL 1.01 Scope Optional Standby Power Generator Systems A. Furnish and install automatic transfer switches

More information

Teseq ESD Simulator Verification

Teseq ESD Simulator Verification Teseq ESD Simulator Verification Background Greg Senko, President Teseq Inc. North American division of Teseq Laboratory Technical Manager Edison NJ This presentation was first given in 2003 when lab was

More information

Electrical System Performance Requirements for Electrical and Electronic Components

Electrical System Performance Requirements for Electrical and Electronic Components DaimlerChrysler DC-10615 Joint Engineering Standard Date Published: 2003-05 Chrysler Category: L-2 Total No. of Pages (Including Annex): 22 Mercedes Benz Category: 22 Chrysler Contact: Terry M. North ADRESS

More information

Series AMEPR30-AZ up to 2.5A AC-DC / DC-DC LED Driver / Converter

Series AMEPR30-AZ up to 2.5A AC-DC / DC-DC LED Driver / Converter FEATURES: Click on Series name for product info on aimtec.com Models Single output Model Max Output Power (W) 1 AC-DC Constant Current or Constant Over temperature protection Voltage LED Driver Over current

More information

EMC & Wireless Certification

EMC & Wireless Certification EMC & Wireless Certification Since 1872, TÜV Rheinland has been a world leader in compliance testing, guaranteeing customer satisfaction with its technical expertise and efficient delivery process. Since

More information

EMC Test for Compliance with EU EMC Directive 2004/108/EU

EMC Test for Compliance with EU EMC Directive 2004/108/EU EMC Test for Compliance with EU EMC Directive 2004/108/EU Partial Test 12-12-2012 Standards Description EN 55022:2011 Information technology equipment - Radio disturbance characteristics - Limits and methods

More information

(PREVIEW) Indian Standard COMMON SPECIFICATION FOR HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR STANDARDS

(PREVIEW) Indian Standard COMMON SPECIFICATION FOR HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR STANDARDS (PREVIEW) Indian Standard COMMON SPECIFICATION FOR HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR STANDARDS IS 12729:2004 IEC 60694(2002) 1.1 Scope This International Standard applies to a.c. switchgear and controlgear,

More information

IEC and CISPR Standards

IEC and CISPR Standards IEC and CISPR Standards With thanks to Gideon Wiid, PhD student, and Paul van der Merwe EE Eng, 2 May, 2007 EMC Definition: Electromagnetic compatibility itself is defined as [1]: "the ability of an equipment

More information

A GENERIC AUTOMOTIVE (TIER1) EMC TEST STANDARD

A GENERIC AUTOMOTIVE (TIER1) EMC TEST STANDARD A GENERIC AUTOMOTIVE (TIER1) EMC TEST STANDARD Martin O Hara The Automotive EMC Network, P.O. Box 3622, Newport Pagnell, MK16 0XT Abstract: The number of different EMC test standards available from the

More information

EC-Declaration of Conformity Annex

EC-Declaration of Conformity Annex 2006/95/EC is given by the compliance with the following European Standard(s). If not EN 61347-1: + A1:2011 EN 61347-2-1. A1:2006 + Corrigendum:2006 EN 61347-2-2: 2012 EN 61347-2-3: 2011 EN 61347-2-7:

More information

Electromagnetic Compatibility Specification For Electrical/Electronic Components and Subsystems

Electromagnetic Compatibility Specification For Electrical/Electronic Components and Subsystems General Specification Electrical/Electronic FMC1278 Electromagnetic Compatibility Specification For Electrical/Electronic Components and Subsystems Foreword This engineering specification addresses Electromagnetic

More information

40 Years of experience in EMC testing

40 Years of experience in EMC testing 40 Years of experience in EMC testing Your reference laboratory for tests of generation, propagation and reception of electromagnetic energy in civil, military and industrial applications. CESI has been

More information

ANSI Watthour Meter Testing & Certification Programs

ANSI Watthour Meter Testing & Certification Programs ANSI Watthour Meter Testing & Certification Programs By Jim Reed Manager, Meter Accuracy Lab and Manasi Bhandiwad Manager, EMC Lab Laboratories, Inc. First in Certification Accreditations and Recognitions

More information

Grounding Demystified

Grounding Demystified Grounding Demystified 3-1 Importance Of Grounding Techniques 45 40 35 30 25 20 15 10 5 0 Grounding 42% Case 22% Cable 18% Percent Used Filter 12% PCB 6% Grounding 42% Case Shield 22% Cable Shielding 18%

More information

Analog signal converters CC-E I/I Current / current isolators

Analog signal converters CC-E I/I Current / current isolators ata sheet Analog signal converters CC-E I/I Current / current isolators The CC-E I/I is an isolator for the electrical isolation of current signals without auxiliary supply. It allows the isolation between

More information

COMMON REGULATORY OBJECTIVES FOR WIRELESS LOCAL AREA NETWORK (WLAN) EQUIPMENT PART 2 SPECIFIC ASPECTS OF WLAN EQUIPMENT

COMMON REGULATORY OBJECTIVES FOR WIRELESS LOCAL AREA NETWORK (WLAN) EQUIPMENT PART 2 SPECIFIC ASPECTS OF WLAN EQUIPMENT COMMON REGULATORY OBJECTIVES FOR WIRELESS LOCAL AREA NETWORK (WLAN) EQUIPMENT PART 2 SPECIFIC ASPECTS OF WLAN EQUIPMENT 1. SCOPE This Common Regulatory Objective, CRO, is applicable to Wireless Local Area

More information

TEST REPORT Rapporto di prova EMC N 060406. Test facility site: via L. da Vinci, 92, Caravaggio (BG), Italy Sede laboratorio

TEST REPORT Rapporto di prova EMC N 060406. Test facility site: via L. da Vinci, 92, Caravaggio (BG), Italy Sede laboratorio TEST REPORT Rapporto di prova EMC N 060406 EUT: Organic Carbon Analyzer Analiuzzatore Carbonio Organico Model: TOCMETER Serial N : TM602 Client: TRE-ESSE s.r.l. Cliente Piazzale Europa 8 16036 Recco (GE),

More information

AKKREDITOITU TESTAUSLABORATORIO ACCREDITED TESTING LABORATORY MICROSOFT MOBILE OY TCC MICROSOFT

AKKREDITOITU TESTAUSLABORATORIO ACCREDITED TESTING LABORATORY MICROSOFT MOBILE OY TCC MICROSOFT T117/M51/2016 Liite 1 / Appendix 1 Sivu / Page 1(20) AKKREDITOITU TESTAUSLABORATORIO ACCREDITED TESTING LABORATORY MICROSOFT MOBILE OY TCC MICROSOFT Tunnus Code Laboratorio Laboratory Osoite Address www

More information

Espotel Test Laboratory Services. November 20, 2014

Espotel Test Laboratory Services. November 20, 2014 Espotel Test Laboratory Services November 20, 2014 Espotel Laboratory Services EMC, ESD, RF testing EMC chamber for radiated emissions and immunity testing Radiated interoperability for LTE, GSM/3G, WLAN

More information

EMC STANDARDS STANDARDS AND STANDARD MAKING BODIES. International. International Electrotechnical Commission (IEC) http://www.iec.

EMC STANDARDS STANDARDS AND STANDARD MAKING BODIES. International. International Electrotechnical Commission (IEC) http://www.iec. EMC STANDARDS The EMC standards that a particular electronic product must meet depend on the product application (commercial or military) and the country in which the product is to be used. These EMC regulatory

More information

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller Overview/Modes of Operation Bulletin 150 Smart Motor Controller The SMC-3 is a compact, simple to use, solid-state motor controller designed to operate 3-phase motors. It features a built-in overload relay

More information

Gain energy insight and control with PowerLogic. PowerLogic EGX300 integrated gateway-server

Gain energy insight and control with PowerLogic. PowerLogic EGX300 integrated gateway-server Gain energy insight and control with PowerLogic PowerLogic EGX300 integrated gateway-server Plug into your energy usage with a simple mouse click The PowerLogic EGX300 is an integrated gateway-server that

More information

Foxboro Evo Process Automation System

Foxboro Evo Process Automation System Foxboro Evo Process Automation System Product Specifications PSS 31H-2Z32 FBM232 Field Device System Integrator Module, 10/100 Mbps Ethernet, Single The FBM232 Field Device System Integrator (FDSI) module

More information

Electromagnetic Compatibility and International Regulatory Approvals

Electromagnetic Compatibility and International Regulatory Approvals Electromagnetic Compatibility and International Regulatory Approvals Most countries have now implemented strict regulations regarding Electromagnetic Compatibility (EMC) for electronic devices. This paper

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994. ALLTITE, INC. 1600 Murdock, Wichita, KS 67214 Bruce Demaree Phone: 800 498 6721

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994. ALLTITE, INC. 1600 Murdock, Wichita, KS 67214 Bruce Demaree Phone: 800 498 6721 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 ALLTITE, INC. 1600 Murdock, Wichita, KS 67214 Bruce Demaree Phone: 800 498 6721 CALIBRATION Valid To: September 30, 2016 Certificate

More information

An extended EMC study of an electrical powertrain for transportation systems

An extended EMC study of an electrical powertrain for transportation systems European Association for the Development of Renewable Energies, Environment and Power Quality (EA4EPQ) International Conference on Renewable Energies and Power Quality (ICREPQ 12) Santiago de Compostela

More information

EMC TEST REPORT For. Shenzhen Homelux Security Equipment Co., Ltd. Auto Dialer. Model No.: HX-GD20

EMC TEST REPORT For. Shenzhen Homelux Security Equipment Co., Ltd. Auto Dialer. Model No.: HX-GD20 EMC TEST REPORT For Shenzhen Homelux Security Equipment Co., Ltd Auto Dialer Model No.: HX-GD20 Prepared for : Shenzhen Homelux Security Equipment Co., Ltd Address : 4 th Floor, Building 5, Jiademaluan

More information

CAT ATC POWER BREAKER & POWER CASE SWITCH AUTOMATIC TRANSFER SWITCH

CAT ATC POWER BREAKER & POWER CASE SWITCH AUTOMATIC TRANSFER SWITCH CAT ATC POWER BREAKER & POWER CASE SWITCH AUTOMATIC TRANSFER SWITCH Cat transfer switches are designed for a variety of standby power applications. They provide flexibility, reliability and value in a

More information

Patient Transport. with the Automated Impella Controller

Patient Transport. with the Automated Impella Controller Patient Transport with the Automated Impella Controller TABLE OF CONTENTS PURPOSE OF THESE INSTRUCTIONS... 2 INDICATION FOR USE... 2 FAA ADVISORY... 2 ABOUT THE IMPELLA SYSTEM... 3 PATIENT TRANSPORT WITH

More information

White Paper: Electrical Ground Rules

White Paper: Electrical Ground Rules Acromag, Incorporated 30765 S Wixom Rd, Wixom, MI 48393 USA Tel: 248-295-0880 Fax: 248-624-9234 www.acromag.com White Paper: Electrical Ground Rules Best Practices for Grounding Your Electrical Equipment

More information

What do SAE standards offer the Automotive Electronics industry?

What do SAE standards offer the Automotive Electronics industry? What do SAE standards offer the Automotive Electronics industry? Just about everything. Volume 2, 2009 SAE standards stand ready to serve industry s growing need for globally harmonized standards solutions.

More information

AN96-07. Surging Ideas TVS Diode Application Note PROTECTION PRODUCTS. TRANSIENT IMMUNITY STANDARDS: IEC 61000-4-x

AN96-07. Surging Ideas TVS Diode Application Note PROTECTION PRODUCTS. TRANSIENT IMMUNITY STANDARDS: IEC 61000-4-x TRANSIENT IMMUNITY STANDARDS: IEC 61000-4-x On January 1, 1996, exports into Europe began facing some tough transient immunity standards. The International Electrotechnical Commission (IEC), a worldwide

More information

Digital Controllers ACTUATOR COMPATABILITY

Digital Controllers ACTUATOR COMPATABILITY Product Specification 36502B DESCRIPTION APECS DPG-21XX-00X Digital Controllers The DPG-21XX-00X digital controller is used primarily to govern diesel or gas fueled engines of generator sets. This microprocessor-based,

More information

Technical Article MS-2443

Technical Article MS-2443 . MS-2443 Safeguard Your RS-485 Communication Networks from Harmful EMC Events by James Scanlon, Senior Evaluation Engineer, Analog Devices, Inc., and Koenraad Rutgers, Senior Field Applications Engineer,

More information

Huawei NE5000E 400Gbps Flexible Line Processing Unit

Huawei NE5000E 400Gbps Flexible Line Processing Unit Huawei NE5000E 400Gbps Flexible Line Processing Unit Huawei NE5000E 400Gbps Flexible Line Processing Unit Overview The Huawei NetEngine5000E router (NE5000E) is a high-end IP core network router. It is

More information

Declaration of Conformity.

Declaration of Conformity. Declaration of Conformity. Type of equipment: Brand Name /Trade Mark: Type designation /model: Applicant: PTZ CAMERA SAMSUNG SCP2371HP SAMSUNG TECHWIN CO., LTD. In accordance with the following Directives:

More information

AN-3 SEVEN KEY CONSIDERATIONS BEFORE YOU START YOUR SLIC OR FXS PHONE LINE INTERFACE DESIGN

AN-3 SEVEN KEY CONSIDERATIONS BEFORE YOU START YOUR SLIC OR FXS PHONE LINE INTERFACE DESIGN AN-3 SEVEN KEY CONSIDERATIONS BEFORE YOU START YOUR SLIC OR FXS PHONE LINE INTERFACE DESIGN By Joe Randolph Introduction The conventional 2-wire analog phone line that telephone companies provide to residential

More information

Waveguide Access Point WGA631. Product Guide

Waveguide Access Point WGA631. Product Guide Waveguide Access Point Product Guide Waveguide Access Point Contents 1. Description............................ 3 2. Application............................ 3 3. Technical data... 4 4. Physical interfaces......................

More information

Rack mounted telephone- and leased line modem for industrial applications

Rack mounted telephone- and leased line modem for industrial applications Rack mounted telephone- and leased line modem for industrial applications TR-6 Rack modem for industrial PSTNand /-wire leased line applications The TR-6 is an analogue V. 9 -rack PSTN modem as well as

More information

The impact of the New EMC Directive 2004/108/EC

The impact of the New EMC Directive 2004/108/EC The impact of the New EMC Directive 2004/108/EC Presentation by Damon High Presentation Overview Brief overview of Electromagnetic Interference and Electromagnetic Compatibility EMC Directive and UK Legislation

More information

WIRELESS MAGNETIC CONTACT

WIRELESS MAGNETIC CONTACT WIRELESS MAGNETIC CONTACT The magnetic contact wireless MAG HCS is a sensor able to detect opening or closing doors or windows and transmits via radio a alarm signal. It is composed of two distinct elements:

More information

Electromagnetic Compatibility Considerations for Switching Power Supplies

Electromagnetic Compatibility Considerations for Switching Power Supplies Electromagnetic Compatibility Considerations Characterization of the EMI problem requires understanding the interference source Switching power supplies generate Electromagnetic Interference (EMI) by virtue

More information

IEC 1000-4-2 ESD Immunity and Transient Current Capability for the SP72X Series Protection Arrays

IEC 1000-4-2 ESD Immunity and Transient Current Capability for the SP72X Series Protection Arrays IEC 00-4-2 ESD Immunity and Transient Current Capability for the SP72X Series Protection Arrays Application Note July 1999 AN9612.2 Author: Wayne Austin The SP720, SP721, SP723, and SP724 are protection

More information

AMP 200N1 LOW FREQUENCY SIGNAL SOURCE DC (0HZ) TO 250KHZ, 800W

AMP 200N1 LOW FREQUENCY SIGNAL SOURCE DC (0HZ) TO 250KHZ, 800W AMP 200N1 LOW FREQUENCY SIGNAL SOURCE DC (0HZ) TO 250KHZ, 800W SELON LES NORMES SUIVANTES... > Chrysler CS-11809 (2009) > Chrysler CS-11979 > Chrysler DC-11224 Rev.A > DaimlerChrysler DC-10614 > DaimlerChrysler

More information

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description Photoelectrics, Background Suppression reflective with IR light Main features Description The PD30ET... stainless steel sensors are built with high-quality materials and designed for harsh environments.

More information

DUAL%CHANNEL BROADBAND%LINEAR%AMPLIFIER Model&A800D

DUAL%CHANNEL BROADBAND%LINEAR%AMPLIFIER Model&A800D ELECTRONICS AB DUAL%CHANNEL BROADBAND%LINEAR%AMPLIFIER Model&A800D & HIGH&VOLTAGE& FIXED&GAIN& BROADBAND & 800Vpp&60mA& 100x& DC&to&ca&200&kHz & LOW&OUTPUT&IMPEDANCE& HIGH&SLEW&RATE &

More information

PE310G4BPi40-T Quad port Copper 10 Gigabit Ethernet PCI Express Bypass Server Intel based

PE310G4BPi40-T Quad port Copper 10 Gigabit Ethernet PCI Express Bypass Server Intel based PE310G4BPi40-T Quad port Copper 10 Gigabit Ethernet PCI Express Bypass Server Intel based Description Silicom s quad port Copper 10 Gigabit Ethernet Bypass server adapter is a PCI-Express X8 network interface

More information

30 In Compliance October 2014 www.incompliancemag.com

30 In Compliance October 2014 www.incompliancemag.com 30 In Compliance October 2014 www.incompliancemag.com Medical Devices in a Wireless World BY IVAYLO TANKOV While wireless technology is now an integral component of a wide variety of manufactured products,

More information

Electronic timer CT-VBS.17+18 OFF-delayed without auxiliary voltage, for DC contactors Data sheet

Electronic timer CT-VBS.17+18 OFF-delayed without auxiliary voltage, for DC contactors Data sheet Characteristics Single-function OFF-delay timer for DC contactors, without auxiliary voltage Width.5 mm CDC 5 6 F3 Approvals A culus E CCC CT-VBS a Circuit diagram b Marker label Marks a CE b C-Tick Order

More information

C-Bus. Single Zone Thermostat. 5070THB Series. Installation Instructions REGISTERED DESIGN REGISTERED PATENT

C-Bus. Single Zone Thermostat. 5070THB Series. Installation Instructions REGISTERED DESIGN REGISTERED PATENT C-Bus Single Zone Thermostat 5070THB Series REGISTERED DESIGN REGISTERED PATENT Clipsal is a registered trademark of Clipsal Australia Pty Ltd ABN 27 007 873 529. Copyright Clipsal Australia Pty Ltd 2008.

More information

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection) Data sheet Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection) The temperature monitoring relays CM-TCS monitor overtemperature,

More information

EMC Basics. Speaker : Alain Lafuente. Alain.lafuente@we-online.com

EMC Basics. Speaker : Alain Lafuente. Alain.lafuente@we-online.com EMC Basics Speaker : lain Lafuente lain.lafuente@we-online.com WHT IS EMC? 2 CE Marking With the formation of the single European market, standardization was required to remove technical barriers to trade.

More information

Panashield, Inc. Facility Solutions For Global Electromagnetic Compatibility

Panashield, Inc. Facility Solutions For Global Electromagnetic Compatibility Panashield, Inc. Facility Solutions For Global Electromagnetic Compatibility Absorber Technologies and Its Impact on Anechoic / Semi Anechoic Chambers Peggy Girard November 2012 Discussion Points Brief

More information

Three-phase monitoring relay CM-PFE

Three-phase monitoring relay CM-PFE Data sheet Three-phase monitoring relay CM-PFE The CM-PFE is a three-phase monitoring relay that monitors the phase parameter phase sequence and phase failure in three-phase mains. 2CDC 251 005 S0012 Characteristics

More information

Automotive Component EMC Testing: CISPR 25, ISO 11452-2 and Equivalent Standards

Automotive Component EMC Testing: CISPR 25, ISO 11452-2 and Equivalent Standards Automotive Component EMC Testing: CISPR 25, ISO 11452-2 and Equivalent Standards Vicente Rodriguez ETS-LindgrenL.P. Email:Vince.Rodriguez@ets-lindgren.com Abstract: This paper presents compiles some information

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSLI Z540-1-1994

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSLI Z540-1-1994 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSLI Z540-1-1994 TEKTRONIX, INC. 13725 SW Karl Braun Drive Beaverton, OR 97077 Andrew Mumford Phone: 503 627 2476 CALIBRATION Valid to: June 30, 2018

More information

Cisco ASR 9001-S Router

Cisco ASR 9001-S Router Data Sheet Cisco ASR 9001-S Router Product Overview Part of the Cisco ASR 9000 Series, the Cisco ASR 9001-S Router (Figure 1) is a compact, high-capacity provider edge router that delivers 60 Gbps of nonblocking,

More information

EMC-conform development of a Tablet-PC

EMC-conform development of a Tablet-PC EMC-conform development of a Tablet-PC January 21, 2014 Johannes Biner Electrosuisse Montena EMC Bernstrasste 93 CH - 3006 Bern Tel. +41 79 256 21 55 Johannes.biner@montenaemc.ch www.montenaemc.ch Programm

More information

Operating Manual UWAPS-TINY Series

Operating Manual UWAPS-TINY Series Operating Manual UWAPS-TINY Series Powecon Oy WWW.POWECON.FI 1/9 Table of content 1 Warranty...3 2 Safety information...3 3 Abbreviations and terminology...3 4 List of appendices...4 5 Introduction...4

More information

Cisco Unified IP Phone Power Injector

Cisco Unified IP Phone Power Injector Data Sheet Cisco Unified IP Phone Power Injector The Cisco Unified IP Phone Power Injector (Figure 1) increases the deployment flexibility of Cisco Unified IP phones by providing an alternative powering

More information

IEEE Electromagnetic Compatibility Standards (Active & Archive) Collection: VuSpec

IEEE Electromagnetic Compatibility Standards (Active & Archive) Collection: VuSpec IEEE Electromagnetic Compatibility Standards (Active & Archive) Collection: VuSpec This value-packed VuSpec CD-ROM represents the most complete resource available for professional engineers looking for

More information

EPL225 Series. 225 Watts. www.xppower.com. AC-DC Power Supplies. Models & Ratings. Summary

EPL225 Series. 225 Watts. www.xppower.com. AC-DC Power Supplies. Models & Ratings. Summary 225 Watts 50 W Convection/ 225 W Forced-cooled Ratings 2 by 4 Footprint Low.26 Profile 2 V Fan Output High Efficiency, up to 95% ITE & Medical pprovals High Power Density Less than 0.5 W No Load Input

More information

AND8229/D. An Introduction to Transient Voltage Suppression Devices APPLICATION NOTE

AND8229/D. An Introduction to Transient Voltage Suppression Devices APPLICATION NOTE An Introduction to Transient Voltage Suppression Devices Prepared by: Jim Lepkowski ON Semiconductor APPLICATION NOTE INTRODUCTION Transient Voltage Suppression (TVS) protection devices such as shielded

More information

MEDICAL DEVICES : Guidance document

MEDICAL DEVICES : Guidance document EUROPEAN COMMISSION DG ENTERPRISE Directorate G Unit 4 - Pressure Equipment, Medical Devices, Metrology MEDICAL DEVICES : Guidance document MEDDEV 2. 2/1 Rev1 February 1998 GUIDELINES RELATING TO THE APPLICATION

More information

AVR040: EMC Design Considerations. 8-bit Microcontrollers. Application Note PRELIMINARY. Scope. 1 Introduction

AVR040: EMC Design Considerations. 8-bit Microcontrollers. Application Note PRELIMINARY. Scope. 1 Introduction AVR040: EMC Design Considerations Scope This application note covers the most common EMC problems designers encounter when using microcontrollers. It will briefly discuss the various phenomena. The reference

More information

Cisco ubr7200-npe-g2 Network Processing Engine

Cisco ubr7200-npe-g2 Network Processing Engine Cisco ubr7200-npe-g2 Network Processing Engine Product Overview With the introduction of the ubr7200-npe-g2 Network Processing Engine, service providers can now take advantage of the enhanced performance

More information

Commission communication in the framework of the implementation of the Council Directive 89/336/EEC (2002/C 190/03)

Commission communication in the framework of the implementation of the Council Directive 89/336/EEC (2002/C 190/03) 10.8.2002 Official Journal of the European Communities C 190/5 Commission communication in the framework of the implementation of the Council Directive 89/336/EEC (2002/C 190/03) (Text with EEA relevance)

More information

Annex of the certificate (Page 1/18) Accreditation Scope

Annex of the certificate (Page 1/18) Accreditation Scope Annex of the certificate (Page 1/18) As a Testing Laboratory Accreditation Nr: Address:Organize Sanayi Bölgesi Büyük Selçuklu Blv. No:2 Sincan 06930 ANKARA / TÜRKİYE Phone : 0 312 267 32 43 Fax : 0 312

More information

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application. 1SR 430 824 F9300 Features Monitoring of three-phase mains for phase sequence and failure Powered by the measuring circuit 2 c/o (SPDT) contacts 1 LED for status indication Approvals R: yellow LED - relay

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD IEC 61131-2 Third edition 2007-07 Programmable controllers Part 2: Equipment requirements and tests Commission Electrotechnique Internationale International Electrotechnical Commission

More information

Communicate and view data from meters with one simple device

Communicate and view data from meters with one simple device Communicate and view data from meters with one simple device PowerLogic EGX300 integrated gateway-server Web Monitoring Communications Plug and Play Plug into your energy usage with a simple mouse click

More information

USB-to-Data Highway Plus Cable

USB-to-Data Highway Plus Cable Installation Instructions USB-to-Data Highway Plus Cable Catalog Number 1784-U2DHP Topic Page Important User Information 2 Environment and Enclosure 3 Install the Cable 5 Configure the DH+ Node Address

More information

Evaluating Cell Phone and Personal Communications Equipment and their EMC Effects on Automotive Audio and In-Cabin Modules

Evaluating Cell Phone and Personal Communications Equipment and their EMC Effects on Automotive Audio and In-Cabin Modules Evaluating Cell Phone and Personal Communications Equipment and their EMC Effects on Automotive Audio and In-Cabin Modules Craig W. Fanning Elite Electronic Engineering, Inc. 1516 Centre Circle Downers

More information

Single-phase (220...240 V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

Single-phase (220...240 V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable Features 70.11 70.31 70.41 Electronic voltage monitoring relays for single and three-phase applications Multifunctional types, providing the flexibility of monitoring Undervoltage, Overvoltage, Window

More information

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact Data sheet Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact The CT-AHD.12 is an electronic time relay with OFF-delay. It is from the CT-D range. With their MDRC profile and a width of only

More information

Standard: EN 61000-4-2 :1995, EN 61000-4-3 :1996, ENV 50204 :1993, & EN 61000-4-4 :1995 Solid State Energy Meter

Standard: EN 61000-4-2 :1995, EN 61000-4-3 :1996, ENV 50204 :1993, & EN 61000-4-4 :1995 Solid State Energy Meter Standard: EN 61000-4-2 :1995, EN 61000-4-3 :1996, ENV 50204 :1993, & EN 61000-4-4 :1995 Model: Solid State Energy Meter Prepared for: Analog Devices, Inc. 804 Woburn Street Wilmington, MA 01887 Date of

More information

1788 Linking Device Specifications

1788 Linking Device Specifications Technical Data 1788 Linking Device Specifications Catalog Numbers 1788-EN2DNROM, 1788-EN2DNR, 1788-EN2FFR, 1788-EN2PAR, 1788-CN2DN, 1788-CN2FFR, 1788-CN2PAR, 1788-FBJB4R, 1788-FBJB6 Topic Page 1788-EN2DNR

More information

A Practical Guide to Dielectric Testing

A Practical Guide to Dielectric Testing Chroma Systems Solutions, Inc. A Practical Guide to Dielectric Testing 19032 Series Electrical Safety Analyzer & 19050 Series Hipot Tester AC/DC/IR/SCAN Keywords: Dielectric tests, insulation resistance

More information

EMC Standards: Standards of good EMC engineering

EMC Standards: Standards of good EMC engineering Electromagnetic Compatibility (EMC) IEEE Definition Origin, control, and measurement of electromagnetic effects on electronic and biologic systems. IEEE EMC Society Areas of Interest EMC Standards: Standards

More information

Bulletin 150 SMC Flex Smart Motor Controller Specifications

Bulletin 150 SMC Flex Smart Motor Controller Specifications Specifications Specifications Standard Features Optional Features Installation Setup Communications Power Wiring Control Wiring Keypad Software Starting and Stopping Modes Protection and Diagnostics Metering

More information

Quality System Overview

Quality System Overview Quality System Overview Agenda Agenda ISO Registration Flow Down Requirements Governance Contract Supplier Quality Performance Inspection Quality Assurance : Project Verification Compliance CE Marking

More information

EMC Supplemental Information and Alternative Component Requirements

EMC Supplemental Information and Alternative Component Requirements DaimlerChrysler DC-11225 Joint Engineering Standard Date Published: 2006-11 Chrysler Category: L-2 Total No. of Pages (Including Annex): 39 Mercedes-Benz Category: 22 Chrysler Author: Terry M. North ADRESS

More information

HEOL-N103-OBD, GPS/GPRS Tracking Module with On Board Diagnostic

HEOL-N103-OBD, GPS/GPRS Tracking Module with On Board Diagnostic HEOL-N103-OBD, GPS/GPRS Tracking Module with On Board Diagnostic Heol fleet tracking system GPS N103 -OBD GPRS FTS Software Internet Main office - Control room Other office The specifications in this document

More information

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1 Power Supply Unit, Primary Switched, Narrow Design MINI POWER provides: Extra narrow design with widths of 22.5 mm, 45 mm, and 67.5 mm (0.886, 1.772, and 2.657 in.) Global use due to a wide-range input

More information

AXIS 291 1U Video Server Rack Installation Guide

AXIS 291 1U Video Server Rack Installation Guide AXIS 291 1U Video Server Rack Installation Guide About This Document This document describes how to install Axis blade video servers in the AXIS 291 1U Video Server Rack. Updated versions of this document

More information

EN 301 489-17 v1.2.1 TEST REPORT FOR. 802.11ag/Draft 802.11n WLAN PCI-E Mini Card MODEL NUMBER: BCM94322MC REPORT NUMBER: 07U11529-5

EN 301 489-17 v1.2.1 TEST REPORT FOR. 802.11ag/Draft 802.11n WLAN PCI-E Mini Card MODEL NUMBER: BCM94322MC REPORT NUMBER: 07U11529-5 EN 301 489-17 v1.2.1 TEST REPORT FOR 802.11ag/Draft 802.11n WLAN PCI-E Mini Card MODEL NUMBER: BCM94322MC REPORT NUMBER: 07U11529-5 ISSUE DATE: JANUARY 29, 2008 Prepared for BROADCOM CORPORATION 190 MATHILDA

More information