Annex of the certificate (Page 1/18) Accreditation Scope

Size: px
Start display at page:

Download "Annex of the certificate (Page 1/18) Accreditation Scope"

Transcription

1 Annex of the certificate (Page 1/18) As a Testing Laboratory Accreditation Nr: Address:Organize Sanayi Bölgesi Büyük Selçuklu Blv. No:2 Sincan ANKARA / TÜRKİYE Phone : Fax : eldas@eldas.com.tr Website : Electrical Laboratory Electricity Metering Equipment Electricity metering equipment (AC)-General requirements, tests and test conditions-part 11: Metering equıpment. All tests Electricity metering equipment (a.c.) - Particular requirements - Part 11:Electromechanical meters for active energy (classes and 2) All Test Electricity metering equipment (a.c.) - Particular requirements - Part 21: Static meters for active energy (classes 1 and 2) All Tests Electricity metering equipment (a.c.) - Particular requirements - Part 22: Static meters for active energy (classes 0,2S and 0,5S) All Tests Electricity metering equipment (a.c.) - Particular requirements - Part 23: Static meters for reactive energy (classes 2 and 3) All Tests Var-Hour (Reactive Energy) Meters. All Tests Electricity metering (a.c.) - Tariff and Load control - Part 21:Particular requirements for time switches. Electricity metering equipment (a.c.) - Part 1 - General requirements, tests and test conditions - Metering equipment (class indexes A, B and C). All Tests TS EN EN IEC TS EN EN IEC TS EN EN IEC TS EN EN IEC TS EN EN IEC TS 786 IEC IEC TS EN EN Article: TS EN EN

2 Annex of the certificate (Page 2/18) Accreditation Nr: Electrical Laboratory Electricty Metering Equipment (continued) Low Voltage Tests (LVD) Household and similar Electrical Stationary cooking ranges, hobs, ovens and similar appliances. Electricity metering equipment (a.c.) - Part 2 - Particular requirements - Electromechanical meters for active energy (class indexes A and B) All Tests Electricity metering equipment (a.c.) - Part 3 - Particular requirements - Static meters for active energy (class indexes A, B and C) All Tests Household and similar electrical appliances - Safety - Part 1: General requirements Household and similar electrical appliances - Safety - Part 2-6: Particular requirements for stationary cooking ranges, hobs, ovens and similar appliances TS EN EN TS EN EN TS EN EN (Article 21.1, Article 22.7, Article 23.3 and Article 30.1 included) TS EN EN (Article 21.1, Article 22.7, Article 23.3 and Article 30.1 included) Grills, toasters and similar portable cooking appliances Household and similar electrical appliances - Safety - Part 2-9: Particular requirements for grills, toasters and similar portable cooking appliances TS 2005 EN EN (Article 21.1, Article 22.7, Article 23.3 and Article 30.1 included) Storage water heaters Household and similar electrical appliances - Safety - Part 2-21: Particular requirements for storage water heaters TS 2212 EN EN (Article 21.1, Article 22.7, Article 23.3 and Article 30.1 included) Room heaters Household and similar electrical appliances- Safety - Part 2-30: Particular requirements for room heaters TS EN EN (Article 21.1, Article 22.7, Article 23.3 and Article 30.1 included)

3 Annex of the certificate (Page 3/18) Accreditation Nr: Instantaneous water heaters Household and similar electrical appliances - Safety - Part 2-35: Particular requirements for instantaneous water heaters TS 6844 EN EN (Article 21.1, Article 22.7, Article 23.3 and Article 30.1 included) Pumps Household and similar electrical appliances. Safety - Part 2-41: Particular requirements for pumps TS EN EN (Article 21.1, Article 22.7, Article 23.3 and Article 30.1 included) Commercial electric dishwashing machines Household and similar electrical appliances - Safety - Part 2-58: Particular requirements for commercial electric dishwashing machines TS EN EN (Article 21.1, Article 22.7, Article 23.3 and Article 30.1 included) Commercial electric forced convection ovens, steam cookers and steam-convection ovens Household and similar electrical appliances - Safety - Part 2-42: Particular requirements for commercial electric forced convection ovens, steam cookers and steam-convection ovens TS EN EN (Article 21.1, Article 22.7, Article 23.3 and Article 30.1 included) Information technology equipment Information technology TS EN equipment - Safety Part 1: EN General requirements Equipment for measurement, control and laboratory use Safety requirements for electrical equipment for measurement, control and laboratory use - Part 1: General requirements TS EN EN Sterilizers and washer-disinfectors used to treat medical materials Safety requirements for electrical equipment for measurement, control and laboratory use - Part 2-040: Particular requirements for sterilizers and washer-disinfectors used to treat medical materials TS EN EN

4 Annex of the certificate (Page 4/18) Accreditation Nr: Electrical equipment of machines Safety of machinery - Electrical TS EN equipment of machines - Part EN : General requirements Medical electrical equipment Medical electrical equipment - Part-1: General requirements for basic safety and essential performance TS EN EN Arc welding equipment Arc welding equipment - TS EN Part-1: Welding power sources EN Household and similar electrical appliances. Household and similar electrical appliances. Electromagnetic fields. Methods for evaluation and measurement 1Hz - 400kHz 320цT - 80mT TS EN EN TS EN EN Electric cooking ranges, hobs, ovens and grills for household use. Electric cooking ranges, hobs, ovens and grills for household use. Methods for measuring performance EN A1/EN Final Products Environmental testing Tests - TS EN Part 2-2: Test B. Dry heat EN Environmental testing Tests - Part 2-1: Test A. Cold TS EN EN Environmental testing Part 2-75: Test methods.test Eh. Hammer tests TS EN EN Degrees of protection provided by enclosures (IP code) TS 3033 EN EN 60529:A1

5 Annex of the certificate (Page 5/18) Accreditation Nr: (Final Products, continued) Environmental testing - Part 2-5: Test methods. Test Sa. Simulated solar radiation at ground level and guidance for solar radiation testing TS EN EN ( Final Products, continued ) Environmental testing Tests - TS EN Part 2-6: Test Fc. Vibration EN (sinusoidal) Environmental testing - Part 2-30: Test-Test Db:Damp heat, cyclic ( 12 h +12 h cycle ) TS EN EN Environmental Testing- Part 2-78: Test metods: Test Cab: Damp heat, steady state Environmental testing Tests - Part 2-27: Test Ea and guidance. Shock TS EN EN TS EN EN Fire hazard testing - Part 2-11: Test methods. Glowing/hot-wire based test methods. Glow-wire flammability test method for end-products TS EN EN Electric irons Household and similar electrical appliances - Safety - Part 2-3: Particular requirements for electric irons IEC EN TS EN Range hoods Household and similar electrical appliances - Safety - Part 2-31 : Particular requirements for range hoods IEC EN TS EN Clothes dryers and towel rails Safety of household and similar electrical appliances-part 2-43:particular requiments for clothes dryers and towel rails IEC EN TS EN

6 Annex of the certificate (Page 6/18) Accreditation Nr: Fans Household and similar electrical appliance- Safety -Part 2-80: Particular requirements for fans IEC EN TS EN High - voltage test techniques for low - voltage equipment High - voltage test techniques for low - voltage equipment - Part 1: Definitions, test and procedure requirements IEC TS EN EN Measurement of standby power Household electrical IEC appliances - Measurement of TS EN standby power EN Safety of power transformers, power supplies, reactors and similar products Household range hoods - Methods for measuring performance Safety of power transformers, power supplies, reactors and similar products -- Part 1: General requirements and tests IEC TS EN EN IEC TS EN EN Low-Voltage power supply devices Low-Voltage power supply devices, d.c. output performance characteristics and safety requirements IEC TS EN EN Uninterruptible Power Systems (UPS) Degrees of protection provided by enclosures for electrical equipment against external mechanical impacts Uninterruptible Power Systems (UPS) - Part 1: General and safety requirements for UPS used in operator access areas Degrees of protection provided by enclosures for electrical equipment against external mechanical impacts (IK code) TS EN EN IEC TS EN EN IEC High Temperature Environmental engineering MIL-STD-810G Metot considerations and laboratory tests -High Temperature Low Temperature Environmental engineering MIL-STD-810G Metot considerations and laboratory tests - Low Temperature Ball pressure test Fire hazard testing - Part 10-2: TS EN Abnormal heat; Ball pressure EN test IEC

7 Annex of the certificate (Page 7/18) Accreditation Nr: ELECTROMAGNETIC COMPABILITY LABORATORY (Information Technology Equipment) Industrial, scientific and medical (ISM) radio-frequency equipment. Equipments which rated current up to 16A Electrical and electronic equipment subjected to conducted directly and air static electricity discharges. Electrical and electronic equipment subjected to radio frequency electromagnetic field Electrical and electronic equipment subjected to repetitive electrical fasttransients Electrical and electronic equipment subjected to unidirectional surges caused by overvoltages from switching and lightning transients. Electrical and electronic equipment subjected to electromagnetic disturbances coming from intended radio-frequency (RF) transmitters Electrical and electronic equipment for household, commercial and industrial applications when subjected to magnetic fields at power frequency Terminal disturbance voltage (150kHz - 30MHz) Emission disturbance (30MHz - 3 GHz) Terminal disturbance voltage (150kHz - 30MHz) Emission disturbance (30MHz - 3 GHz) Harmoniks Voltage fluctuations and flicker (Short and long term) Electrostatic discharge immunity test (Conducted 2 kv - 8 kv, Air :2 kv - 15 kv) Radiated, radio-frequency, electromagnetic field immunity Electrical fast transient/burst immunity test Surge immunity test Immunity to conducted disturbances, induced by radio-frequency fields Power frequency magnetic field immunity test TS EN 55022/A1 EN 55022/A1 CISPR 22 TS 3327 EN 55011/A2 EN 55011/A1/A2 CISPR 11 TS EN EN /A2 IEC TS EN /A2 EN IEC TS EN EN IEC TS EN /A1 EN /A1 IEC Test Frequency:20 MHz-3GHz Field Level: up to 30 V/m TS EN EN IEC TS EN EN IEC TS EN EN IEC TS EN EN /A1 IEC

8 Annex of the certificate (Page 8/18) Accreditation Nr: Electrical and electronic equipment connected to low voltage power supply networks for voltage dips, short interruptions, and voltage variations Devices which contains electrical and electronic equipment under operational conditions and shows ring waves Residential, commercial and light-industrial environments devices Voltage dips, short interruptions and voltage variations immunity tests Ring wave immunity test (EMC) - Part 6-3: Generic standards. Emission standard for residential, commercial and light-industrial environments (EMC) - Part 6-3: Generic standards. Immunity for residential, commercial and light-industrial environments TS EN EN IEC TS EN EN IEC TS EN EN IEC TS EN EN IEC Industrial environments devices (EMC) - Part 6-4: Generic standards. Emission standard for industrial environments TS EN EN IEC (EMC) - Part 6-2: Generic standards - Immunity for industrial environments TS EN EN IEC Information technology equipment Information technology equipment. Immunity characteristics. Limits and methods of measurement TS EN EN 55024/A2 CISPR 24 Water Meters Measurement of water flow in fully charged closed conduits - Meters for cold potable water and hot water - Part 3: Test methods and equipment ISO (Article ) Water meters. Test methods and equipment Electromagnetic immunity tests BS EN /A1(Article )

9 Annex of the certificate (Page 9/18) Accreditation Nr: Natural Gas Meters Gas meters. Diaphragm gas meters Electromagnetic immunity and emission tests. TS 5910 EN 1359/T1 (Article C.5.1-C.5.2-C.5.4) EN 1359 Medical Electrical Equipments Medical electrical equipmentgeneral requirements for basic safety and essential performance. Collateral standard.. Requirements and tests TS EN EN IEC Devices (meters) which contain electricity measurement equipment Electricity metering equipment (AC). General requirements, tests and test conditions - Part: 11 - Metering equipment TS EN (Article 7.5) EN IEC Household appliances Electromagnetic compatibility. Requirements for household appliances, electric tools and similar apparatus immunity. Product family standard TS EN / IS1 EN /A2 CISPR14-2. Requirements for household appliances, electric tools and similar apparatus. Emission tests. TS EN EN /A1 CISPR 14-1 Electrical equipment for measurement, control and laboratory use. Electrical equipment for measurement, control and laboratory use. EMC requirements. General requirements. Electromagnetic immunity and emission. TS EN 61326/A3 TS EN EN EN IEC 61326

10 Annex of the certificate (Page 10/18) Accreditation Nr: Control equipments for lifts, escalators and moving walks. Electromagnetic compatibility. Product family standard for lifts, escalators and moving walks. Immunity tests. TS EN 12016/A1 EN (Only electrical/electronical apparatus and sub-parts contain). Product family standard for lifts, escalators and moving walks. Emission tests. TS EN EN (Only electrical/electronical apparatus and sub-parts contain) Shielded Enclosures Anechoic chambers. Part - 1: Shield attenuation measurement TS EN EN (Only between frequency 10 khz-3 GHz) Equipments which rated current up to 16 A. (EMC)Testing and measurement techniques. Harmonics and interharmonics including mains signalling at a.c. power port, low frequency immunity tests TS EN EN /A1 (EMC)Testing and measurement techniques. Voltage fluctuation immunity test for equipment with input current not exceeding 16 A per phase TS EN /A1 EN /A2 (EMC)Testing and measurement techniques. Ripple on d.c. input power port immunity test. TS EN /A1 EN /A2 Arc welding equipment. Arc welding equipment. (EMC) requirements. Immunity and emission tests. TS EN EN

11 Annex of the certificate (Page 11/18) Accreditation Nr: Low voltage power supplies Low voltage power supplies, d.c. output. Electromagnetic compatibility (EMC). Immunity and emission tests TS EN EN Road traffic signal systems.. TS EN Road traffic signal systems. EN Product standard Automatic Control Schemes Alarm Systems Automatic electrical controls for household and similar use. General requirements. Product family standard: Immunity requirements for components of fire, intruder and social alarm systems TS 7425 EN /A16 EN /A16 (Article 23-Emission and Article 26-Immunity) TS EN /A2 EN /A2 Electrical relays Electrical relays. Electromagnetic emission tests for measuring relays and protection equipment TS EN EN Electrical relays. requirements for measuring relays and protection equipment. Immunity tests. TS EN EN (Table 6.5 Excluding) Electricity metering equipment (a.c.) Part 1: General requirements, tests and test conditions. Electromagnetic immunity and emmision tests for metering equipment (class indexes A, B and C) TS EN EN (Article 7.4) Part 2: Particular requirements. Electromagnetic immunity and emmision tests for electromechanical meters for active energy (class indexes A and B) TS EN EN (Article ; ; ; ; )

12 Annex of the certificate (Page 12/18) Accreditation Nr: (Electricity metering equipment (a.c.), continued) Technical condition for radio equipment and services Special conditions for Short-Range Devices (SDR) operating on frequencies between 9 khz and 40 khz for radio equipment and services. Automative and Parts Part: 3 Particular requirements. Static meters for active energy (class indexes A, B and C) and Radio spectrum Matters (ERM) - ElectroMagnetic Compatibility (EMC) standard for radio equipment and services.immunity and emission tests. and Radio spectrum Matters (ERM) - ElectroMagnetic Compatibility (EMC) standard for radio equipment and services. Immunity and emission tests. Electromagnetic immunity and emission tests for motor vehicles and parts. TS EN EN (Madde ; ; ; ; ; ) TS EN V1.8.1 ETSI :V1.8.1 (Article8.2and8.7Excluding) TS EN V1.4.1 ETSI : V1.4.1 (ETSI Standards Article 8.2 and 8.7 Excluding) 72/245/AT 72/245/EEC Construction machinery. of machines with internal electrical power supply. Immunity and emission tests TS EN EN Earth-moving machinery Earth-moving machinery - ISO Immunity and emission tests Dynamic measuring systems for liquids Dynamic measuring systems for liquids other than water Immunity Tests (Electrical disturbance tests) OIML R (Article A.11) Dynamic measuring instruments. General requirements for OIML D 11 measuring instruments - (Article 12; 13) Environmental conditions Equipmet with rated current 16A up to 75A (EMC). Limits. Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems. Equipment with rated voltage current 75 A and subject to conditional connection TS EN EN IEC

13 Annex of the certificate (Page 13/18) Accreditation Nr: (Equipmet with rated current 16A up to 75A, continued) Road Vehicles (Impact 2a - 2b and 5b excluded) The immunity test of electrical and electronic equipment against damped oscillatory waves (EMC)Limits. Limits for harmonic currents produced by equipment connected to public low-voltage systems with input current 16 A and 75 A per phase Electrical disturbances from conducting and coupling. Part: 2 Electrical transient conduction along supply lines only. (EMC). Testing and measurement techniques. Damped oscillatory wave immunity test TS EN EN IEC ISO (Article 4.3. Voltage Transient Emission Test excluding) TS EN EN IEC Uninterruptible power systems (UPS) Electrical lighting and similar equipment (EMC) requirements Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipment TS EN EN IEC TS EN 55015/A1/A2 EN 55015/A1/A2 CISPR 15/A1/A2 Electrical lighting equipment Equipment for general lighting purposes. EMC immunity requirements TS EN EN 61547/A1 EN IEC Electrical apparatus for the detection and measurement of combustible gases, toxic gases or oxygen TS EN TS EN Electrical and electronic installations in ships Electrical and electronic installations in ships. IEC 60533

14 Annex of the certificate (Page 14/18) Accreditation Nr: Shielded Test Environments Standard Method for Measuring Effectiveness of Electromagnetic Shielded Enclousers IEEE STD 299 Military Equipments; Electrical / Electronical and Electromechanical Devices and Subsystems Rotating electrical machines Conducted Emission CE102 (10kHz - 10MHz) Radiated emission RE102 (10kHz - 3GHz) Radiated Emission RE101 (30Hz - 100kHz) Rotating electrical machines - Part 1: Rating and performance MIL STD461E MIL STD461E MIL STD461E MIL STD461F MIL STD461E MIL STD461F TS EN (Article 13 EMU terms) 2,4 GHz Broad band transmission system, 5 GHz high performance RLAN device and 5,8 GHz broad band for data transmission systems Electromagnetic compatibility and Radio spectrum Matters (ERM); ElectroMagnetic Compatibility (EMC) standard for radio equipment; Part 17: Specific conditions for Broadband Data Transmission 2,4 GHz Broad band transmission system, 5 GHz high performance RLAN device and 5,8 GHz broad band special requirements for data transmission systems (up to 3 GHz) TS EN V1.3.2 ETSI EN :V2.1.1 (Article 8.2 excepting)

15 Annex of the certificate (Page 15/18) Accreditation Nr: Short Range Devices (SRD); Radio equipment to be used in the 25 MHz to MHz frequency range with power levels ranging up to 500 mw; WATER METER LABORATORY Water Meter Electromagnetic compatibility and Radio spectrum Matters (ERM); Short Range Devices (SRD); Radio equipment to be used in the 25 MHz to MHz frequency range with power levels ranging up to 500 mw; Part 1: Technical characteristics and test methods Pressure Loss Test ETSI EN V1.3.1 TS10021Article4 ISO4064-3Article7 Water Meter Directive 75/33/ATArticle3.4 TS EN A2Article5.11 Static Pressure Test Error( of Indication ) Test Endurance Test TS10021Article3 ISO4064-3Article6 75/33/AT Article3.3 TS EN A2Article5.2 TS10021 Article 2 ISO Article 5 cold-water meters Directive 75/33/AT Article 5 TS EN A2 Article5.4 TS10021 Article 5 ISO Article 8 75/33/AT Article 5 TS EN A2 Article 5.13 Reverse Flow Test Absence of Flow Test Water Temperature Test (T50) ISO4064-3Article5.11 TS EN A2Article5.12 EN A2Article5.5 TS EN A2Article6.4

16 Annex of the certificate (Page 16/18) Accreditation Nr: (WATER METER LABORATORY Water Meter, continued) GAS METER LABORATORY Natural Gas Meter GAS BURNING DEVICES LABORATORY Cooking Devices (Burning Gas) Water Pressure Test Verification of Flow Profile Sensitivity Classes Cold Test Dry Heat Test Damp Heat Cyclic Test Overload Water Temperature Test Resistance to internal Pressure Meter Case Sealing Connections Resistance to impact Ultraviolet Exposure Test -Domestic cooking appliances burning gas Safety- General Domestic cooking appliances burning gas- Safety- Appliances having one or more burners with an automatic burner Domestic cooking appliances burning gas-rational use of energy. General ISO4064-3Article5.10 TS EN A2Article5.8 TS EN A2Article5.9 ISO4064-3Article5.12 TS EN A2Article6.2.2 ISO4064-3Article TS EN A2Article6.2.1 ISO4064-3Article9.3.1 TS EN A2 (Article 6.2.3) ISO (Article 9.3.3) TS EN A2Article5.7 TS 5910EN1359/T1 TS 5910EN1359 EN1359/A1(E) Article6.2.3 TS 5910EN1359/T1 TS 5910EN1359 EN1359/A1(E) Article6.2.4 TS 5910EN1359/T1 TS 5910EN1359 EN1359/A1(E) Article6.2.5 TS 5910EN1359/T1 TS 5910EN1359 EN1359/A1(E) Article6.2.7 TS 5910EN1359/T1 TS 5910EN1359 EN1359/A1(E) Article8.3.2 TS EN TS EN30-1-1/AC TS EN30-1-1/A2 TS EN30-1-1/A2/AC TS EN TS EN TS EN30-1-4/A1 TS EN TS EN30-2-1/A2 TS EN30-2-1/A1

17 Annex of the certificate (Page 17/18) Accreditation Nr: (GAS BURNING DEVICES LABORATORY Cooking Devices (Burning Gas), continued) Barbecues ( Burning Gas) LPG Devices Heaters (Gas Burning Flueless) Industrial Type Cooking Appliances Kitchen Devices (Open Burners and Wok Burners) Kitchen Devices (Ovens) Domestic cooking appliances burning gas-rational use of energy. General Domestic cooking appliances burning gas. SafetyAppliances having forced-convection ovens and/or grills Domestic cooking appliances burning gas. Rational use of energyappliances having forced-convection ovens and/or grills Specification for dedicated liquefied petroleum gas appliances. Barbecues for outdoor use contact grills included Specification for dedicated LPG appliances. Room sealed LPG space heating equipment for installation in vehicles and boats (Except Article6.23, , ) Specification for dedicated liquefied petroluem gas appliances. Flueless non-domestic space heaters not exceeding 10 kw (except Article6.13.3,6.23.3) Gas heated catering equipment- General safety Rules (Except Article , , 7.6.3) Gas heated catering equipment- Specific requirements - Open Burners and Wok Burners (Article ) Gas heated catering equipment- Specific requirements - Ovens TS EN30-2-1/A1/AC TS EN TS EN TS EN498 EN 498 TS EN624 EN 624 TS EN461 TS EN461/A1 TS EN203-1+A1 EN A1 TS EN EN TS EN EN

18 Annex of the certificate (Page 18/18) Accreditation Nr: Kitchen Devices (Boiling Pans) Kitchen Devices (Fryers) Kitchen Devices (Hot Water Heaters) Laundry Machines Dryers Gas heated catering equipment- Specific requirements - Boiling Pans Gas heated catering equipment - Specific requirements - Fryers Gas heated catering equipment- Specific requirements -Hot water Heaters for beverage Domestic gas-fired washing machines, of nominal heat input not exceeding 20 kw- Part 1: Safety (Except Article6.18, , ) Gas-fired type B tumble dryers of nominal heat input not exceeding 20 kw (Except Article , ) End of Scope TS EN EN TS EN EN TS EN EN TS EN EN TS EN EN Dr. H. İbrahim ÇETİN Deputy Secretary General

Commission communication in the framework of the implementation of the Council Directive 89/336/EEC (2002/C 190/03)

Commission communication in the framework of the implementation of the Council Directive 89/336/EEC (2002/C 190/03) 10.8.2002 Official Journal of the European Communities C 190/5 Commission communication in the framework of the implementation of the Council Directive 89/336/EEC (2002/C 190/03) (Text with EEA relevance)

More information

(PREVIEW) Indian Standard COMMON SPECIFICATION FOR HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR STANDARDS

(PREVIEW) Indian Standard COMMON SPECIFICATION FOR HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR STANDARDS (PREVIEW) Indian Standard COMMON SPECIFICATION FOR HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR STANDARDS IS 12729:2004 IEC 60694(2002) 1.1 Scope This International Standard applies to a.c. switchgear and controlgear,

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 COMPLIANCE TESTING, LLC 1724 S Nevada Way Mesa, AZ 85204 Phone: 480 926 3100 Michael Schafer (Authorized Representative/President) Email michaels@compliancetesting.com

More information

TEST REPORT EN 55014-2 (1997) +A1 (2001)

TEST REPORT EN 55014-2 (1997) +A1 (2001) Page 1 of 23 TEST REPORT EN 55014-2 (1997) +A1 (2001) Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus Part 2: Immunity Report Reference No....

More information

IEC and CISPR Standards

IEC and CISPR Standards IEC and CISPR Standards With thanks to Gideon Wiid, PhD student, and Paul van der Merwe EE Eng, 2 May, 2007 EMC Definition: Electromagnetic compatibility itself is defined as [1]: "the ability of an equipment

More information

STRATO LED Drivers 70W, Single output

STRATO LED Drivers 70W, Single output Features STRATO switch mode driver technology is designed to generate one constant current output from a wide range AC input. The size and performance of these products make them the ideal choice for LED

More information

Dual Chamber Temporary External Pacemaker

Dual Chamber Temporary External Pacemaker 5392 Dual Chamber Temporary External Pacemaker Electromagnetic Compatibility Declaration Caution: Federal law (USA) restricts this device to sale by or on the order of a physician. The following list includes

More information

CE MARK TECHNICAL FILE AS/NZS EMC CONSTRUCTION FILE

CE MARK TECHNICAL FILE AS/NZS EMC CONSTRUCTION FILE CE MARK TECHNICAL FILE AS/NZS EMC CONSTRUCTION FILE of Product Name Model Brand Memorex; Imation; TDK Life on Record Contains: 1. Declaration of Conformity 2. EN55022/CISPR 22, AS/NZS CISPR 22 EMI test

More information

Espotel Test Laboratory Services. November 20, 2014

Espotel Test Laboratory Services. November 20, 2014 Espotel Test Laboratory Services November 20, 2014 Espotel Laboratory Services EMC, ESD, RF testing EMC chamber for radiated emissions and immunity testing Radiated interoperability for LTE, GSM/3G, WLAN

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 1

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 1 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 1 BUREAU VERITAS ADT (SHANGHAI) CORPORATION 2F, Building C, No. 1618. Yishan Road 201103 Shanghai, CHINA Ms. Mary Gu (Authorized Representative) Phone: 86 21

More information

40 Years of experience in EMC testing

40 Years of experience in EMC testing 40 Years of experience in EMC testing Your reference laboratory for tests of generation, propagation and reception of electromagnetic energy in civil, military and industrial applications. CESI has been

More information

COMMON REGULATORY OBJECTIVES FOR WIRELESS LOCAL AREA NETWORK (WLAN) EQUIPMENT PART 2 SPECIFIC ASPECTS OF WLAN EQUIPMENT

COMMON REGULATORY OBJECTIVES FOR WIRELESS LOCAL AREA NETWORK (WLAN) EQUIPMENT PART 2 SPECIFIC ASPECTS OF WLAN EQUIPMENT COMMON REGULATORY OBJECTIVES FOR WIRELESS LOCAL AREA NETWORK (WLAN) EQUIPMENT PART 2 SPECIFIC ASPECTS OF WLAN EQUIPMENT 1. SCOPE This Common Regulatory Objective, CRO, is applicable to Wireless Local Area

More information

Test Report. Prepared for: Technologic Systems, Inc. Model: TS-8820

Test Report. Prepared for: Technologic Systems, Inc. Model: TS-8820 Test Report Prepared for: Technologic Systems, Inc. Model: TS-8820 Description: Single Board Computer with Analog and Digital Inputs and Outputs, Relays, and RS-232/485 Ports To IEC 61000-6-1 (2005-03)

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD IEC 61131-2 Third edition 2007-07 Programmable controllers Part 2: Equipment requirements and tests Commission Electrotechnique Internationale International Electrotechnical Commission

More information

EC-Declaration of Conformity Annex

EC-Declaration of Conformity Annex 2006/95/EC is given by the compliance with the following European Standard(s). If not EN 61347-1: + A1:2011 EN 61347-2-1. A1:2006 + Corrigendum:2006 EN 61347-2-2: 2012 EN 61347-2-3: 2011 EN 61347-2-7:

More information

Waveguide Access Point WGA631. Product Guide

Waveguide Access Point WGA631. Product Guide Waveguide Access Point Product Guide Waveguide Access Point Contents 1. Description............................ 3 2. Application............................ 3 3. Technical data... 4 4. Physical interfaces......................

More information

EMC STANDARDS STANDARDS AND STANDARD MAKING BODIES. International. International Electrotechnical Commission (IEC) http://www.iec.

EMC STANDARDS STANDARDS AND STANDARD MAKING BODIES. International. International Electrotechnical Commission (IEC) http://www.iec. EMC STANDARDS The EMC standards that a particular electronic product must meet depend on the product application (commercial or military) and the country in which the product is to be used. These EMC regulatory

More information

IEEE Electromagnetic Compatibility Standards (Active & Archive) Collection: VuSpec

IEEE Electromagnetic Compatibility Standards (Active & Archive) Collection: VuSpec IEEE Electromagnetic Compatibility Standards (Active & Archive) Collection: VuSpec This value-packed VuSpec CD-ROM represents the most complete resource available for professional engineers looking for

More information

Rated Power(W) 8W 2. EG-LED0840-01 8W 3. EG-LED1027-01 10W

Rated Power(W) 8W 2. EG-LED0840-01 8W 3. EG-LED1027-01 10W 14713221 001 Seite 2 von 37 Page 2 of 37 Model List: No Model Rated Voltage(V) 1. EG-LED0827-01 Rated Power(W) 8W 2. EG-LED0840-01 8W 3. EG-LED1027-01 10W 4. EG-LED1040-01 AC 100-240V, 10W 5. EG-LED1027-02

More information

Chrome DIN Rail Power Supply 12V 54W 1 Phase (Class II & NEC Class 2) / DRC-12V60W1AG

Chrome DIN Rail Power Supply 12V 54W 1 Phase (Class II & NEC Class 2) / DRC-12V60W1AG Highlights & Features Protection Class II, Double Isolation (No Earth connection is required) Universal AC input voltage and full power up to 55 C Power will not de-rate for the entire input voltage range

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD IEC 61131-2 Second edition 2003-02 Programmable controllers Part 2: Equipment requirements and tests Automates programmables Partie 2: Spécifications et essais des équipements IEC

More information

High Frequency Power Quality

High Frequency Power Quality High Frequency Power Quality Dr. Ing. Jos Knockaert, MSc jos.knockaert@ugent.be CE-ABLE Seminar 21st June 2016-1 Project: TETRA HFPQ funded by Dec 2014 Nov 2016 Main goals: - How to measure? - What are

More information

AKKREDITOITU TESTAUSLABORATORIO ACCREDITED TESTING LABORATORY MICROSOFT MOBILE OY TCC MICROSOFT

AKKREDITOITU TESTAUSLABORATORIO ACCREDITED TESTING LABORATORY MICROSOFT MOBILE OY TCC MICROSOFT T117/M51/2016 Liite 1 / Appendix 1 Sivu / Page 1(20) AKKREDITOITU TESTAUSLABORATORIO ACCREDITED TESTING LABORATORY MICROSOFT MOBILE OY TCC MICROSOFT Tunnus Code Laboratorio Laboratory Osoite Address www

More information

RM4TG20 three-phase network control relay RM4-T - range 200..500 V

RM4TG20 three-phase network control relay RM4-T - range 200..500 V Characteristics three-phase network control relay RM4-T - range 200..500 V Complementary [Us] rated supply voltage Output contacts Setting accuracy of time delay Delay at power up Measuring cycle Marking

More information

SINGAPORE CONSUMER PROTECTION (SAFETY REQUIREMENTS) REGISTRATION SCHEME

SINGAPORE CONSUMER PROTECTION (SAFETY REQUIREMENTS) REGISTRATION SCHEME Controlled Goods are required to be tested to the minimum edition of the safety standards stated in this chapter. In addition to the specified safety standards, Controlled Goods are required to fulfil

More information

Chrome DIN Rail Power Supply 24V 30W 1 Phase (Class II & NEC Class 2) / DRC-24V30W1AZ

Chrome DIN Rail Power Supply 24V 30W 1 Phase (Class II & NEC Class 2) / DRC-24V30W1AZ Highlights & Features Protection Class II, Double Isolation (No Earth connection is required) Universal AC input voltage without power de-rating Efficiency > 87.0% @ 115Vac & 230Vac NEC Class 2 / Limited

More information

Thermistor motor protection relays CM-MSS.22 and CM-MSS.23

Thermistor motor protection relays CM-MSS.22 and CM-MSS.23 Data sheet Thermistor motor protection relays CM-MSS.22 and CM-MSS.23 The thermistor motor protection relays CM-MSS.22 and CM-MSS.23 monitor the winding temperature of motors and protect them from overheating,

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 YANFENG AUTOMOTIVE TRIM SYSTEMS CO. LTD. China Technical Center No. 1001 North Qinzhou Rd. Shanghai, China 200233 Shao Xiong (Test Center Manager/Local Authorized

More information

CERTIFICATE OF CONFORMITY

CERTIFICATE OF CONFORMITY AIRBAKE ALL-CLAD ARNO CALOR CLOCK KRUPS LAGOSTINA MIRRO MOULINEX PANEX PENEDO REGAL ROCHEDO ROWENTA SAMURAI SEB SUPOR TEFAL T-FAL WEAREVER CERTIFICAT DE CONFORMITE CERTIFICATE OF CONFORMITY N DQNE-02-22611

More information

Single-phase (220...240 V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

Single-phase (220...240 V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable Features 70.11 70.31 70.41 Electronic voltage monitoring relays for single and three-phase applications Multifunctional types, providing the flexibility of monitoring Undervoltage, Overvoltage, Window

More information

EMC Test for Compliance with EU EMC Directive 2004/108/EU

EMC Test for Compliance with EU EMC Directive 2004/108/EU EMC Test for Compliance with EU EMC Directive 2004/108/EU Partial Test 12-12-2012 Standards Description EN 55022:2011 Information technology equipment - Radio disturbance characteristics - Limits and methods

More information

Test Report #: 1981-3 Date: April 8, 2005

Test Report #: 1981-3 Date: April 8, 2005 Test Report #: 1981-3 Date: April 8, 2005 CERTIFICATE #2316.01 Issued To: Bill Burks American Power Conversion 85 Rangeway Road North Billerica, MA 01862 USA 978-670-2440 Product Name/Description Model

More information

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection) Data sheet Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection) The temperature monitoring relays CM-TCS monitor overtemperature,

More information

How to Self-Certify For the CE Mark A Quick Start Guide by Dennis King - EMI Test Lab

How to Self-Certify For the CE Mark A Quick Start Guide by Dennis King - EMI Test Lab How to Self-Certify For the CE Mark A Quick Start Guide by Dennis King - EMI Test Lab For questions and details contact Dennis at dennis@emitestlab.com Introduction The CE mark (an acronym for the French

More information

Chrome DIN Rail Power Supply 24V 91.2W 1 Phase (Class II & NEC Class 2) / DRC-24V100W1AZ

Chrome DIN Rail Power Supply 24V 91.2W 1 Phase (Class II & NEC Class 2) / DRC-24V100W1AZ Highlights & Features Protection Class II, Double Isolation (No Earth connection is required) Universal AC input voltage without power de-rating Efficiency > 87.0% @ 115Vac, > 89.0% @ 230Vac NEC Class

More information

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector Product datasheet Characteristics TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector Main Range of product Product or component type Range compatibility Enclosure material Bus

More information

Cable Solutions for Servo and Variable Frequency Drives (VFD)

Cable Solutions for Servo and Variable Frequency Drives (VFD) Cable Solutions for Servo and Variable Frequency Drives (VFD) Electric drive systems with continuous torque and speed control are widespread today. They allow an optimal adjustment of the drive with respect

More information

TECHNICAL SPECIFICATION FOR GSM MOBILE TERMINALS

TECHNICAL SPECIFICATION FOR GSM MOBILE TERMINALS TECHNICAL SPECIFICATION FOR GSM MOBILE TERMINALS Suruhanjaya Komunikasi dan Multimedia Malaysia Off Pesiaran Multimedia, 63000 Cyberjaya, Selangor Darul Ehsan, Malaysia Copyright of SKMM, 2007 FOREWORD

More information

TECHNICAL SPECIFICATION FOR BROADBAND WIRELESS ACCESS (BWA) EQUIPMENT

TECHNICAL SPECIFICATION FOR BROADBAND WIRELESS ACCESS (BWA) EQUIPMENT TECHNICAL SPECIFICATION FOR BROADBAND WIRELESS ACCESS (BWA) EQUIPMENT Suruhanjaya Komunikasi dan Multimedia Malaysia Off Pesiaran Multimedia, 63000 Cyberjaya, Selangor Darul Ehsan, Malaysia Copyright of

More information

7.5 Watt AC-DC Switch Power Supply

7.5 Watt AC-DC Switch Power Supply MAIN FEATURES: 7.5W Small Compact Size PCB Mount Single Output Regulated Output Range : 3.3VDC 24VDC Input Range : 85VAC 265VAC/47 63Hz Or 120VDC 370VDC Very Low Standby Power Consumption < 0.15W Better

More information

Patient Transport. with the Automated Impella Controller

Patient Transport. with the Automated Impella Controller Patient Transport with the Automated Impella Controller TABLE OF CONTENTS PURPOSE OF THESE INSTRUCTIONS... 2 INDICATION FOR USE... 2 FAA ADVISORY... 2 ABOUT THE IMPELLA SYSTEM... 3 PATIENT TRANSPORT WITH

More information

Foxboro Evo Process Automation System

Foxboro Evo Process Automation System Foxboro Evo Process Automation System Product Specifications PSS 31H-2Z32 FBM232 Field Device System Integrator Module, 10/100 Mbps Ethernet, Single The FBM232 Field Device System Integrator (FDSI) module

More information

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages Data sheet Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages The CM-ESS.2 is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of

More information

LAB 1 TECHNICAL DOC 3 IN ONE LAB DEVICE. Velleman Legen Heirweg 33 9890 Gavere Belgium

LAB 1 TECHNICAL DOC 3 IN ONE LAB DEVICE. Velleman Legen Heirweg 33 9890 Gavere Belgium LAB 1 TECHNICAL DOC 3 IN ONE LAB DEVICE Velleman Legen Heirweg 33 9890 Gavere Belgium SPECIFICATIONS DIGITAL MULTIMETER 3 1/2 backlit LCD Automatic polarity indication DC voltage 200mV to 600V in 5 steps

More information

Regulatory Compliance Services and Products

Regulatory Compliance Services and Products Regulatory Compliance Services and Products Compliance Testing EMC, Safety, Radio, Telecoms, EMF Consultancy & Research Regulatory Compliance, Management & RF Engineering Training Courses & Workshops Test

More information

Three-phase monitoring relay CM-PFE

Three-phase monitoring relay CM-PFE Data sheet Three-phase monitoring relay CM-PFE The CM-PFE is a three-phase monitoring relay that monitors the phase parameter phase sequence and phase failure in three-phase mains. 2CDC 251 005 S0012 Characteristics

More information

Analog signal converters CC-E I/I Current / current isolators

Analog signal converters CC-E I/I Current / current isolators ata sheet Analog signal converters CC-E I/I Current / current isolators The CC-E I/I is an isolator for the electrical isolation of current signals without auxiliary supply. It allows the isolation between

More information

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact Data sheet Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact The CT-AHD.12 is an electronic time relay with OFF-delay. It is from the CT-D range. With their MDRC profile and a width of only

More information

Experience with taximeters with a look at the corresponding tables

Experience with taximeters with a look at the corresponding tables Experience with taximeters with a look at the corresponding tables Milan Prasil CMI Laboratory of the fundamental metrology V Botanice 4, 150 72 Prague 5 mprasil@cmi.cz Taximeters in EU are subject to

More information

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages Data sheet Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages The CM-ESS.M is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of

More information

EMC & Wireless Certification

EMC & Wireless Certification EMC & Wireless Certification Since 1872, TÜV Rheinland has been a world leader in compliance testing, guaranteeing customer satisfaction with its technical expertise and efficient delivery process. Since

More information

30 In Compliance October 2014 www.incompliancemag.com

30 In Compliance October 2014 www.incompliancemag.com 30 In Compliance October 2014 www.incompliancemag.com Medical Devices in a Wireless World BY IVAYLO TANKOV While wireless technology is now an integral component of a wide variety of manufactured products,

More information

Nya och reviderade standarder 2014

Nya och reviderade standarder 2014 Här presenterar vi alla nya och reviderade standarder från år 2014. Standardlistan hittar du alltid på www.intertek.se/om-oss/intertekinfo Nya och reviderade standarder 2014 Standardnummer Namn Standarden

More information

NMI M 6-2 Electricity Meters. Part 2: Test Report Format

NMI M 6-2 Electricity Meters. Part 2: Test Report Format NMI M 6-2 Electricity Meters Part 2: Test Report Format Commonwealth of Australia 2010 First edition September 2010 National Measurement Institute Bradfield Road, Lindfield, NSW 2070 PO Box 264, Lindfield,

More information

Gas Detector System, Portable/Fixed Oxygen Analysis and Gas Detection Equipment

Gas Detector System, Portable/Fixed Oxygen Analysis and Gas Detection Equipment STANDARD FOR CERTIFICATION No. 2.9 TYPE APPROVAL PROGRAMME NO. 7-473.30/31 / MED A.1/3.30/54 Gas Detector System, Portable/Fixed Oxygen Analysis and Gas Detection Equipment SEPTEMBER 2011 The content of

More information

EMC Standards: Standards of good EMC engineering

EMC Standards: Standards of good EMC engineering Electromagnetic Compatibility (EMC) IEEE Definition Origin, control, and measurement of electromagnetic effects on electronic and biologic systems. IEEE EMC Society Areas of Interest EMC Standards: Standards

More information

ANSI Watthour Meter Testing & Certification Programs

ANSI Watthour Meter Testing & Certification Programs ANSI Watthour Meter Testing & Certification Programs By Jim Reed Manager, Meter Accuracy Lab and Manasi Bhandiwad Manager, EMC Lab Laboratories, Inc. First in Certification Accreditations and Recognitions

More information

Series AMEPR30-AZ up to 2.5A AC-DC / DC-DC LED Driver / Converter

Series AMEPR30-AZ up to 2.5A AC-DC / DC-DC LED Driver / Converter FEATURES: Click on Series name for product info on aimtec.com Models Single output Model Max Output Power (W) 1 AC-DC Constant Current or Constant Over temperature protection Voltage LED Driver Over current

More information

DATA SHEET DVI - HDCP Extension Cable

DATA SHEET DVI - HDCP Extension Cable DATA SHEET DVI - HDCP Extension Cable Contents Description Features Absolute Maximum Ratings Recommended Operating Conditions Electrical Power Supply Characteristics Receiver Electrical Interface Specifications

More information

Three-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41

Three-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41 Data sheet Three-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41 The three-phase monitoring relays CM-PSS.x1 monitor the phase parameters phase sequence, phase failure as well as over- and undervoltage.

More information

TEST REPORT Rapporto di prova EMC N 060406. Test facility site: via L. da Vinci, 92, Caravaggio (BG), Italy Sede laboratorio

TEST REPORT Rapporto di prova EMC N 060406. Test facility site: via L. da Vinci, 92, Caravaggio (BG), Italy Sede laboratorio TEST REPORT Rapporto di prova EMC N 060406 EUT: Organic Carbon Analyzer Analiuzzatore Carbonio Organico Model: TOCMETER Serial N : TM602 Client: TRE-ESSE s.r.l. Cliente Piazzale Europa 8 16036 Recco (GE),

More information

Telephone- and leased line modem for industrial applications TD-36

Telephone- and leased line modem for industrial applications TD-36 Telephone- and leased line modem for industrial applications TD-36 Modem for industrial PSTN- and leased line applications The TD-36 is an analogue V.34 PSTN modem as well as an industrial 2-wire leased

More information

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application. 1SR 430 824 F9300 Features Monitoring of three-phase mains for phase sequence and failure Powered by the measuring circuit 2 c/o (SPDT) contacts 1 LED for status indication Approvals R: yellow LED - relay

More information

Electronic timer CT-VBS.17+18 OFF-delayed without auxiliary voltage, for DC contactors Data sheet

Electronic timer CT-VBS.17+18 OFF-delayed without auxiliary voltage, for DC contactors Data sheet Characteristics Single-function OFF-delay timer for DC contactors, without auxiliary voltage Width.5 mm CDC 5 6 F3 Approvals A culus E CCC CT-VBS a Circuit diagram b Marker label Marks a CE b C-Tick Order

More information

Harmonics and Noise in Photovoltaic (PV) Inverter and the Mitigation Strategies

Harmonics and Noise in Photovoltaic (PV) Inverter and the Mitigation Strategies Soonwook Hong, Ph. D. Michael Zuercher Martinson Harmonics and Noise in Photovoltaic (PV) Inverter and the Mitigation Strategies 1. Introduction PV inverters use semiconductor devices to transform the

More information

CAT ATC POWER BREAKER & POWER CASE SWITCH AUTOMATIC TRANSFER SWITCH

CAT ATC POWER BREAKER & POWER CASE SWITCH AUTOMATIC TRANSFER SWITCH CAT ATC POWER BREAKER & POWER CASE SWITCH AUTOMATIC TRANSFER SWITCH Cat transfer switches are designed for a variety of standby power applications. They provide flexibility, reliability and value in a

More information

15 Series - Electronic step relay and dimmer. Features 15.91 15.51 15.81 SERIE

15 Series - Electronic step relay and dimmer. Features 15.91 15.51 15.81 SERIE Series - Electronic step relay and dimmer SERIE Features.91.51.81 Electronic step relay and dimmer for control of lighting levels Suitable for incandescent and halogen lighting loads (with or without transformer

More information

ENVIRONMENTAL TEST SPECIFICA- TION FOR INSTRUMENTATION AND AUTOMATION EQUIPMENT

ENVIRONMENTAL TEST SPECIFICA- TION FOR INSTRUMENTATION AND AUTOMATION EQUIPMENT STANDARD FOR CERTIFICATION No. 2.4 ENVIRONMENTAL TEST SPECIFICA- TION FOR INSTRUMENTATION AND AUTOMATION EQUIPMENT APRIL 2006 FOREWORD (DNV) is an autonomous and independent foundation with the objectives

More information

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller Overview/Modes of Operation Bulletin 150 Smart Motor Controller The SMC-3 is a compact, simple to use, solid-state motor controller designed to operate 3-phase motors. It features a built-in overload relay

More information

CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.

CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data. 425 CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE General purpose single phase thyristors and solid state relays Product data abc 425 EUROCUBE A complete range of low cost solid state relays and

More information

Cisco ASR 9001-S Router

Cisco ASR 9001-S Router Data Sheet Cisco ASR 9001-S Router Product Overview Part of the Cisco ASR 9000 Series, the Cisco ASR 9001-S Router (Figure 1) is a compact, high-capacity provider edge router that delivers 60 Gbps of nonblocking,

More information

38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A

38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A 38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit EMR Electromechanical Relays

More information

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages Data sheet Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages The CM-ESS.2 is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of

More information

RM17TE 183...528 V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

RM17TE 183...528 V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC Characteristics multifunction control relay RM17-TE - range 183..528 V AC Complementary Reset time Maximum switching voltage Minimum switching current Maximum switching current [Us] rated supply voltage

More information

ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories

ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories 2CDC 251 014 F0t09 Features Monitoring of three-phase mains for grid feeding Type-tested in accordance with DIN V VDE V 0126-1-1: February 2006 Neutral conductor connection configurable Can also be used

More information

Fusible Disconnect Switch

Fusible Disconnect Switch Circuit Breakers Circuit breakers are used in panelboards and switchboards to provide circuit protection and provide a means of energizing and de-energizing a circuit. Siemens Sentron molded case circuit

More information

Features. Picture. Specifications

Features. Picture. Specifications Type: for level measurement Order No.: see Table 1 / Page 4 Features Picture Two wire system Piezoresistive measuring element Output signal 4-20 ma Conformity error ±0.5 % FS or Standard DIN measuring

More information

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description Photoelectrics, Background Suppression reflective with IR light Main features Description The PD30ET... stainless steel sensors are built with high-quality materials and designed for harsh environments.

More information

XPress-Pro SW Series Hardened Ethernet Switches Enabling Communication for the Demanding Industrial Environment

XPress-Pro SW Series Hardened Ethernet Switches Enabling Communication for the Demanding Industrial Environment XPress-Pro SW Series Hardened Ethernet Switches Enabling Communication for the Demanding Industrial Environment Part of the device networking family of networkenablement products, XPress-Pro SW series

More information

NMI R 118 Testing Procedures and Test Report Format for Pattern Evaluation of Fuel Dispensers for Motor Vehicles (OIML R 118:1995(E), NEQ)

NMI R 118 Testing Procedures and Test Report Format for Pattern Evaluation of Fuel Dispensers for Motor Vehicles (OIML R 118:1995(E), NEQ) Testing Procedures and Test Report Format for Pattern Evaluation of Fuel Dispensers for Motor Vehicles (OIM R 118:1995(E), NEQ) The English version of international standard OIM R 118:1995 Testing Procedures

More information

Application Note AN001

Application Note AN001 AN001 SRD regulations for licence free transceiver operation By P. M. Evjen Keywords CEPT recommendations ETSI standards R&TTE directive Part 15 devices Type approval Equipment testing Operating frequency

More information

Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated. Ordering information

Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated. Ordering information Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated Ordering information Connection technique Description Description Rated operational current Screw terminals 3 pole AC

More information

ENVIRONMENTAL TESTING

ENVIRONMENTAL TESTING ENVIRONMENTAL TESTING Mobility Department Environmental Testing Foreword & Introduction Tests Heat - Cold - Climate Page 3 Thermal Shock Page 4 Low - High Pressure Page 4 Vibration Page 5 Mechanical Shock

More information

Electromagnetic Compatibility Considerations for Switching Power Supplies

Electromagnetic Compatibility Considerations for Switching Power Supplies Electromagnetic Compatibility Considerations Characterization of the EMI problem requires understanding the interference source Switching power supplies generate Electromagnetic Interference (EMI) by virtue

More information

CE Marking and Technical Standardisation

CE Marking and Technical Standardisation GAMBICA Technical Guide CE Marking and Technical Standardisation Guidelines for application to Electrical Power Drive Systems Edition 4 : 2015 CE Marking and Technical Standardisation Guidelines for application

More information

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features Central 48 V DC Power Supplies for PoE-Components MICROSENS Description Active network equipment which is supporting the Power-over-Ethernet functions, typically requires a powerful 48 V DC power supply.

More information

RM35UA13MW. range 15..600 V. Main. Product or component type. Relay monitored parameters

RM35UA13MW. range 15..600 V. Main. Product or component type. Relay monitored parameters Characteristics multifunction voltage control relay RM35-U - range 15..600 V Complementary Reset time Maximum switching voltage [Us] rated supply voltage Supply voltage limits Power consumption in W Main

More information

EverFlo. EverFlo Q EN, DE DSF 4/16/08

EverFlo. EverFlo Q EN, DE DSF 4/16/08 1053621 EN, DE DSF 4/16/08 EverFlo EverFlo Q English Table of Contents Symbol Key... 2 Abbreviations... 2 Chapter 1: Introduction... 3 Intended Use... 3 About Your EverFlo / EverFlo Q...3 Parts of Your

More information

38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A

38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A 38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A 38 SERIES Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit EMR Electromechanical

More information

Bulletin 150 SMC Flex Smart Motor Controller Specifications

Bulletin 150 SMC Flex Smart Motor Controller Specifications Specifications Specifications Standard Features Optional Features Installation Setup Communications Power Wiring Control Wiring Keypad Software Starting and Stopping Modes Protection and Diagnostics Metering

More information

Energy Management Energy Meter Type EM23 DIN

Energy Management Energy Meter Type EM23 DIN Energy Management Energy Meter Type EM23 DIN Class 1 (kwh) according to EN62053-21 Class B (kwh) according to EN50470-3 Class 2 (kvarh) according to EN62053-23 Accuracy ±0.5 RDG (current/voltage) Energy

More information

1756 ControlLogix Power Supplies Specifications

1756 ControlLogix Power Supplies Specifications Technical Data 1756 ControlLogix Power Supplies Specifications Standard Power Supplies Catalog Numbers 1756-PA72, 1756-PA75, 1756-PB72, 1756-PB75, 1756-PC75, 1756-PH75 Standard Slim Power Supplies Catalog

More information

US Installation Manual Smappee Monitor

US Installation Manual Smappee Monitor US Installation Manual Smappee Monitor Version 1.3 English, US, version 1.3, revision 23, as of October 23, 2014, 2013 Smappee NV. All rights reserved. Specifications are subject to change without notice.

More information

USB-to-Data Highway Plus Cable

USB-to-Data Highway Plus Cable Installation Instructions USB-to-Data Highway Plus Cable Catalog Number 1784-U2DHP Topic Page Important User Information 2 Environment and Enclosure 3 Install the Cable 5 Configure the DH+ Node Address

More information

Fired up about safety

Fired up about safety APPLIANCES Safety testing and certification services for gas and electrical Fired up about safety raising standards worldwide TM With increasing concerns over climate change and consumer safety, there

More information

OpenWay Radio Frequency FAQ

OpenWay Radio Frequency FAQ OpenWay Radio Frequency FAQ March 10, 2010 2010, Itron Inc. All rights reserved. 1 Overview This document provides general information about radiofrequency (RF) electromagnetic fields from OpenWay wireless

More information

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: 2868567. DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: 2868567. DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase Extract from the online catalog STEP-PS/1AC/12DC/1.5 Order No.: 2868567 DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase Commercial data EAN 4046356292924 Pack 1 pcs. Customs tariff

More information

OIML R 117-2 RECOMMENDATION. Edition 2014 (E) ORGANISATION INTERNATIONALE INTERNATIONAL ORGANIZATION

OIML R 117-2 RECOMMENDATION. Edition 2014 (E) ORGANISATION INTERNATIONALE INTERNATIONAL ORGANIZATION INTERNATIONAL RECOMMENDATION OIML R 117-2 Edition 2014 (E) Dynamic measuring systems for liquids other than water. Part 2: Metrological controls and performance tests Ensembles de mesurage dynamique de

More information

INTERNATIONAL ELECTROTECHNICAL COMMISSION. Guidance for users of the CISPR Standards

INTERNATIONAL ELECTROTECHNICAL COMMISSION. Guidance for users of the CISPR Standards 1 INTERNATIONAL ELECTROTECHNICAL COMMISSION INTERNATIONAL SPECIAL COMMITTEE ON RADIO INTERFERENCE (CISPR) 1 Introduction Guidance for users of the CISPR Standards This guidance document is presented to

More information