Grounding Fittings. Conductor Range Dimensions in Inches Catalog AWG/kcmil Number Min. Max. A B CTGC-6-25A
|
|
- Erick Sanders
- 7 years ago
- Views:
Transcription
1 M1 able Tray Ground lamp M1 Type TG Terminates ground wire to cable tray. For aluminum or copper conductors. 1 4 hex wrench tightens both tray and conductor set screws. Tray-gripping serrations bite through insulating oxide on surface of aluminum tray. For 1 2 max. straight tray rail, or tray rail. size #6 to 20 MM lamp - Extruded luminum/tin Plated Screws - Steel/Zinc Electroplated Options: Stainless steel screws are available - add suffix SS S ertified: For copper conductors only. Range atalog WG/kcmil Number Min. Max. TG Tray Side S Standard: 22.2 No. 41 NE and 18-6 Side Type TG Ground Rod lamps ommodity Grade R To ground a conductor to a driven ground rod. High strength cast bronze. Suitable for direct burial. Material: Suitable for direct burial. S ertified: 0720 UL Standard 467 S Standard: 22.2 No. 41 National Electrical ode rticles 20-2, 20- and 20- NEM: F-1 R Screw Max. Ground Thread Range Width atalog Rod Size Size WG Max. cross Side Number Inches (UN-2) Min. Max. Height Open End Length GR GR GR / GR /
2 M2 Universal Ground lamp System uilt-in connector M2 W see Page M For connecting grounding conductors to cold water ground pipe in sizes through 12. Standard built-in ground wire connector for #8 Sol. through #2 Str. WG wire. Provision for separate 2-station attachment of additional swivel accessories are listed in ground clamp accessories tables. See page M-. clamps are suitable for direct burial. atalog Numbers with suffix G are Malleable Iron, Hot ip Galvanized. olts and Nuts are Steel, Hot ip or Mechanically Galvanized. atalog Numbers with suffix are ast ronze with Silicon ronze olts and Nuts. S ertified: S Standard: 22.2 No. 18 Ground Pipe with W rmor Ground Wire onnector H see Page M Ground Pipe with H Ground Hub ccessories: (see page M) For larger conductors add W dead end terminals. For connecting conductors run in conduit, add H swivel ground hubs. For connecting armored ground wire, add W Terminal. Malleable ast Iron ronze Ground Pipe Size atalog atalog Nominal O.. Range Height Number Number Size Min. Max. Thk. Width Max. U-olt G-200G G G-0G G G-00G G G-600G G G-800G G G-1000G G G-1200G G ES Flexible Ground Strap.92 pg. M2 ES-02 H pg. M To provide flexible connection between ground hub and universal clamp. Material: opper S Standard: 22.2 No ES-02 Note: Suitable for direct burial when used with clamps and accessories that are suitable for direct burial. Existing ES-02 between Hub and Ground lamp Number of atalog of Straps Mounting Strap Max. Ground Number (Required) enters Width Holes Thickness Wire Size GES WG/kcmil /0 WG/kcmil /0 WG/kcmil WG/kcmil
3 M Universal Ground lamp ccessories M H, GW & GW - Swivel Types For use with the universal ground clamps to connect grounding conductors run bare, in armor, or in conduit. Fits all basic ground clamp systems, G-200G through G-1200G and G-200 through G See Page M2. H-G - Malleable Iron-Hot ip Galvanized; Steel Screws Zinc Electroplated H- -, rass Screws W -, Silicon ronze Screws W -, rass Screws UL Listed: E24264 H-G Malleable Iron Hot ip Galvanized H- Note: ll cast bronze and brass accessories are suitable for direct burial. W W GROUN HUS Malleable ast Iron ronze Range atalog atalog Hub Trade WG/kcmil Number Number Size (In.) Min. Max. Max. H GH-0G GH GH-7G GH / GH-100G GH GH-12G GH / RMORE GROUN WIRE ONNETOR Range atalog WG/kcmil Max. Number Min. Max. rmor ia. Max. GW-04 8 Sol. 4 Str W RE OR INSULTE WIRE E EN TERMINL HU Range atalog WG/kcmil Number Min. Max. Max. GW Mcm GW-0 4/0 00 Mcm W
4 M4 Heavy uty Ground lamps M4 F-19G ombination rmored lamp or are Ground Wire For connecting armored or bare grounding wire to ground pipe Ground Range atalog Pipe Size WG lamp Number Inches Min. Max Height Width Width GF-19G 1/2-/ Malleable Iron, Hot ip or Mechanically Galvanized Screws are Steel, Zinc Electroplated F-19G -0 Heavy uty Ground lamp w/swivel Hub for threaded rigid conduit or IM. For connecting grounding conductor (run in conduit) to ground pipe. Malleable Iron, Hot ip or Mechanically Galvanized Screws: Steel/Zinc Electroplated -0G Ground Range Pipe Size atalog WG/kcmil onduit enter to lamp Inches Number Min. Max. Top of Fitting Width 1 2 G-0G G-1G 6 1/ G & -2G 1 G-2G 1/
5 M Pipe Ground lamps ommodity Grade For bare wire For armored cable H With conduit hub To ground a conductor to metallic pipe, tubing or ground rod. High strength cast copper alloy Screws electroplated to resist corrosion Material: asting - opper lloy Screws - Steel Finish: opper lloy - Natural finish Screws - Zinc Electroplated M G: are wire clamp from #10 solid to # stranded WG. G: rmored cable or rigid conduit clamp from #8 solid to #4 stranded WG. GH: Rigid conduit clamp from #10 solid #4 stranded WG. G, GH and G are reversible for attachment to ground rods. S ertified: H onduit Top of Ground Range Hub Pipe to atalog Pipe Size WG Size lamp Top of Number Inches Min. Max. Inches Height Width Width Fitting G G G GH S Standard : 22.2 No. 41 National Electrical ode rticle 20-26(c), 20-2, 20- NEM: F-1
SPEC AMERICAN. SPEC BRIDGEPORT.
SPE MERIN. SPE RIDGEPORT. ridgeport Zinc or Steel Meets: UL514 Specifications: --50552 Fittings for able and Flexible Metal onduit --50553 Fittings for Rigid and EMT onduit --50563 onduit Outlet oxes,
More informationSeries 1 Steel Cable Ladder
able Straight Sections See pages LDS-3 & LDS-4 Straight Section overs See page LDS-10 ccessories See pages LDS-5 - LDS-9 Fittings See pages LDS-11 - LDS-17 Fitting overs See page LDS-10 LDS-1 able Support
More informationTS 813 GROUNDING AND BONDING TTD 813.001 TRAFFIC SIGNAL INSTALLATION AND CONTROLLER CABINET GROUNDING SYSTEM TTD 813.005 CONTROLLER CABINET GROUNDING
TORONTO TRANSPORTATION January 2012 TS 813 GROUNDING AND BONDING TABLE OF CONTENTS 1. DRAWINGS TTD 813.001 TRAFFIC SIGNAL INSTALLATION AND CONTROLLER CABINET GROUNDING SYSTEM TTD 813.005 CONTROLLER CABINET
More informationNORTH ORANGE COUNTY COMMUNITY COLLEGE DISTRICT SECTION 27 05 26 GROUNDING AND BONDING FOR COMMUNICATION SYSTEMS
SECTION GROUNDING AND BONDING FOR COMMUNICATION SYSTEMS RELATED SECTIONS: Section 27 00 00 General Requirements Section 27 02 00 Communication General Requirements Section 27 05 28 Pathways for Communications
More informationSECTION 15140 - PIPE HANGERS AND SUPPORTS
Part I - GENERAL 1.01 SECTION INCLUDES A. The work covered under this section consists of the furnishing of all necessary labor, supervision, materials, equipment, and services to completely execute the
More informationTARIFF CODE and updates standard
TARIFF CODE and updates standard No HS CODE AHTN CODE PRODUCT DESCRIPTION PRODUCT TYPE STANDARDS IDENTIFIED 7207 Semi finished products of iron or non alloy steel Containing by weight less than 0.25% of
More informationLIQUIDTIGHT FITTINGS
ooper rouse-hinds LIQUITIGHT FITTINGS LiQuik Series no disassembly required! Liquidator Series Low Profile Series Zinc ie ast Series Non-Metallic Liquidtight Series LIQUITIGHT FITTINGS LiQuik Series Liquidator
More informationCable Supports. Requirements for Cable Supports in the National Electrical Code reads as follows:
QA1 General Information are used to support cables in vertical raceways or risers. Cable supports relieve the strain that would be placed on terminations, the interior of panels, or other devices to which
More informationCDGRD-10. Grounding. Solutions For Comm/Data Applications
CDGRD-10 Grounding Solutions For Comm/Data Applications Overview & Table of Contents Cooper B-Line s Grounding products for rack & runway provide a complete solution for grounding metal supports. The offering
More informationANTENNA PARTS CATALOG
ANTENNA PARTS CATALOG Maco Antennas 302 S. East St. Mt. Carroll, IL 61053 www.macoantennas.net 815-244-3500 www.antennapartsoutlet.com SCREWS / BOLTS PART SIZE LENGTH DESCRIPTION PRICE S21 10-24 1/2" Machine
More information18 AWG thru 8 AWG Not greater than 100/30 100/30. 6 AWG thru 1/0 AWG Not greater than 200/60 100/30
Commercial Products COMMERCIAL PRODUCTS: RIGID AND IMC FITTINGS s Used to support cables in vertical raceways or risers. Relieves the strain that would be placed on terminations, the interior of panels,
More informationTYPICAL WIRING OF METER SOCKET FOR SINGLE PHASE, THREE WIRE OVERHEAD SERVICE
TYPICAL WIRING OF METER SOCKET FOR SINGLE PHASE, THREE WIRE OVERHEAD SERVICE A. GENERAL NOTES: Service entrance line and load conductors, conduit straps, weatherhead, lock nuts, bushings, connectors, and
More informationTelescoping Post Indicator Wall Post KENNEDY VALVE ISO 9000 ISO 14001
Telescoping Post Indicator Wall Post KENNEDY VALVE ISO 9000 ISO 14001 Telescoping Post Indicator 2945 A 1" SQUARE STEM 9" MAX. = 10" MIN. = 7" FIELD ADJUSTMENT INSTRUCTIONS 1. Remove the top section from
More informationELECTRICAL SERVICE REQUIREMENTS FOR MOBILE HOME DEVELOPMENTS
Prepared by: ABB1 ELECTRICAL SERVICE REQUIREMENTS FOR MOBILE HOME DEVELOPMENTS 052521 Asset Type: Electric Metering Function: Construction Issued by: Quoc Hoang (QxH1) Date: 07-01-16 Rev. #06: This document
More informationROOF DRAINS TABLE OF CONTENTS
Pictorial Index Product Recommendations Roof Drain Selection Factors Sizing Placement Material & Characteristics Pipe Connection Commonly Specified Options Typical Installations TABLE OF CONTENTS ROOF
More informationMini USB and USB 2.0-IP67 Connector System
Mini USB and USB 2.0-IP67 Connector System Section 12 Mini USB and USB 2.0-IP67 Connector System CONEC has added the Mini-USB connector. This Mini-USB IP67 receptacle and plug family, feature a bayonet
More informationCat. No. Finishes & Materials. Standard Finish: Electrogalvanized. Change suffix to SS6(C).
Superstrut Support Systems 1-5/8 in. x 1-5/8 in. Channel and Hardware Superstrut 1-5/8 in. x 1-5/8 in. - 12 Gauge Channel Type A Solid Base Punched Description Solid base -P Punched -HS Half slots Half
More informationCable management Steel wire cable trays
Cable management Steel wire cable trays Due to their high quality design, ABB steel wire cable trays are suitable for industrial, commercial, and other applications where demanding or difficult operating
More informationTwo most common lock nut groups: 1-Prevailing Torque Type Lock Nuts:
Two most common lock nut groups: 1. PREVAILING TORQUE a design feature of the lock nut produces friction between threads of mated components thereby increasing the force needed to tighten as well as loosen
More information1 & 2 CIRCUIT. Architectural grade ISO 9001 quality JIT availability Open architecture ready for your fixtures now!
L I G H T I N G T R A C K S Y S T E M S & CIRCUIT Architectural grade ISO 900 quality JIT availability Open architecture ready for your fixtures now! Your lighting track source. Nordic Aluminium is the
More informationSTB Series Enclosures
STB Series Enclosures Features/Applications: The STB series of sheet steel enclosures are designed to meet the requirement for distribution and lighting junction boxes. Available in 14 sizes with standard
More informationPOWERS Controls No. 4 Pneumatic Damper Actuator
POWERS Controls No. 4 Pneumatic Damper Actuator Technical Instructions Document No. 155-032P25 AP 331-2 Actuator Assembly 331-2929 Typical Actuator Assembly 331-2904 Typical Actuator Assembly 331-3000
More informationSECTION 27 05 36 CABLE TRAYS FOR COMMUNICATIONS SYSTEMS
SECTION 27 05 36 CABLE TRAYS FOR COMMUNICATIONS SYSTEMS PART 1 GENERAL 1.01 DESCRIPTION A. The work covered by this section of the Specifications includes all labor necessary to perform and complete such
More informationEHV CONNECTORS EHV TERMINALS ACFS (EHV)... ALUMINUM BOLTED TUBE TO FLAT PAD, SHORT...EHV-7
CONNECTORS TERMINALS ACF ()... BOLTED TUBE TO FLAT PAD...- ACFS ()... BOLTED TUBE TO FLAT PAD, SHORT...-7 CCL-... COMPRESSION TUBE TO FLAT PAD...- CCLS-... COMPRESSION TUBE TO FLAT PAD, SHORT... - EVKET...
More informationAnodes and Misc Equipment
Anodes and Misc Equipment Application: Platinised Titanium Anodes Platinised titanium anodes are recommended for use in the following electrolytic processes:- Precious metal electroplating - e.g. Au, Pt,
More informationDouble-Headed Screw 1. 3/4" FIP x 3/4" MIP x 1/4" hole 2. 3/4" Fip x 3/4" MIP. Feed Water Connector 1. 1/2" FIP x 1/2" MIP x 1/4" OD 2. 3.
Picture Item No. Description RO- 0010 Brass Water Feed 1. 3/4" FIP with 1/4" hole 2. Using on R.O. tank RO- O020 Double-Headed Screw 1. 3/4" FIP x 3/4" MIP x 1/4" hole 2. 3/4" Fip x 3/4" MIP RO- 0030 Brass
More informationCommando Industrial Plugs and Sockets
1:20 Description comprehensive range of industrial plugs, connectors, socket outlets and appliance inlets. The products are designed to meet IE.309 and S EN.60309-2 offering a choice of IP44 splashproof
More informationBolted Connectors & Terminals
Disconnect Tee Connecr Type ADT5 75 Body 90 Nom. Function: ADT connecrs provide a convenient means of connecting lugged service conducrs overhead mains conducrs. Construction: Body - High strength cast
More informationTECHNICAL SPECIFICATION FOR HIGH TENSION LINE HARDWARE AND ACCESSORIES FOR ACSR PANTHER & WOLF CONDUCTOR
TECHNICAL SPECIFICATION FOR HIGH TENSION LINE HARDWARE AND ACCESSORIES FOR ACSR PANTHER & WOLF CONDUCTOR 1.1.0 SCOPE : This specification covers design, manufacture, testing at manufacture s works before
More informationLinear Luminaire for Fluorescent Lamps Series EXLUX 6001
> As wall, ceiling and pendant light fitting or side entry lamp > Version with 2 lamps: 18 W, 36 W and 58 W > Central locking > All-pole disconnection by means of an N/C switch when the lamp is opened
More informationC O N V E Y O R C O M P O N E N T S C H A I N S B E L T S B E A R I N G S
C O N V E Y O R C O M P O N E N T S C H A I N S B E L T S B E A R I N G S January 2009 Issue 6 Valu Guide Brackets The Ultimate in Adjustability and Cost Savings Valu Guide brackets are part of a family
More informationChapter 9. Bonding and Grounding
Chapter 9 Bonding and Grounding Objectives Describe why the cable should be bonded Describe bonding and grounding procedures Define Bonding and Grounding Explain Safety Benefits and intent of bonding and
More informationINDICATOR POST STYLE 2945 A TELESCOPING BARREL ASSEMBLY UL AND FM APPROVED
INDICATOR POST STYLE 2945 A TELESCOPING BARREL ASSEMBLY UL AND FM APPROVED Available in Sizes B C D E See Page 6 for Dimensions Kennedy Valve/Indicator Posts 17-1 INDICATOR POST STYLE 2945 A TELESCOPING
More informationONTRAC WIRE MESH CABLE TRAY SYSTEM
P R O D U C T D ATA S H E E T ONTRAC WIRE MESH CABLE TRAY SYSTEM K E Y F E AT U R E S Available in two styles: Shaped and Standard Tray Easy to use pathway solution that supports large quantities of network
More informationCATHODIC PROTECTION SYSTEM DESIGN
CATHODIC PROTECTION SYSTEM DESIGN Presented By DENIS L ROSSI P.E. CORROSION ENGINEER New England C P Inc. Corrosion Fundamentals What is corrosion? It is defined as the degradation or deterioration of
More information3M Mobile SkyWalk Series Horizontal Lifeline Product Return Form
3M Mobile SkyWalk Series Horizontal Lifeline Product Return Form THIS FULLY COMPLETED DOCUMENT MUST BE INCLUDED WITH EACH RETURN SHIPMENT IN ORDER FOR CREDIT TO BE ISSUED. ALL CREDITS WILL BE ISSUED TO
More informationAluminium Standard. Technical Data. Included in delivery
luminium Standard UL / cul Robust aluminium enclosure for mechanical engineering and automation technology Fixing options for s and mounting plates Usable in wide temperature area Technical ata aterial:
More informationPOLARIS INSUL-TAP CONNECTORS FOR TWO WIRES & IN-LINE SPLICERS/REDUCERS
INSUL-TAP CONNECTORS FOR TWO S & IN-LINE SPLICERS/REDUCERS IT SERIES 1 2 3 4 Insul-Tap connectors are suitable for connecting two wires. For sizes 3/0 AWG and smaller, they are available in two styles
More informationSTANDARD SPECIFICATIONS SECTION 05500 METAL FABRICATIONS
STANDARD SPECIFICATIONS SECTION 05500 METAL FABRICATIONS PART 1 GENERAL 1.1 DESCRIPTION A. Section includes requirements for providing metal fabricated items like castings, gratings, hatchways, ladders,
More informationKIRÁLY TRADING KFT H-1151 Budapest Mogyoród útja 12-14 tel: 061307-3801 Email_pzoli@kiralytrading.hu. Clamps Clamping devices
04000 Clamps Clamping devices 23000 22000 21000 20000 09000 08000 07000 06000 05000 04000 03000 02000 01000 297 04010 Adjustable straps Tempered steel 1.1191 Black oxide finish nlm 04010-101 Suitable thrust
More informationAll work must conform to the National Electric Code, latest edition, and all other applicable codes and regulations.
DIVISION 16 ELECTRICAL SECTION 16100 - ELECTRICAL PART 1 - GENERAL SCOPE All electrical work as shown on the drawings and as necessary to provide a complete electrical system. Include primary service,
More informationValu Guide Sheaths. Valu Guide Inserts. Optional Valu Guide Inserts. Typical Properties of Valu Guide Rail. and Hardware.
14 gauge stainless steel The Original, Long Life Sanitary Guide Rail Valu Guide rail incorporates two outstanding materials: stainless steel and UHMW. The 14 ga. stainless steel sheath provides rigid streamlined
More informationSTREETLIGHT SYSTEM GROUNDING AND BONDING
Page: 1 of 8 STREETLIGHT SYSTEM GROUNDING AND BONDING 1. Scope This Construction Standard covers the grounding and bonding requirements for single phase streetlight systems served by the Looped Radial
More informationTerminal Boxes Series 8146
Series > Enclosures in shock-resistant glass fibre reinforced polyester resin > basic enclosure sizes various heights > Fitted according to the customer's requirements > For terminals up to max. 00 mm
More informationMany Products...One Source
PRESSURE GAUGES Dedicated Sales Rep for Your Area 97%Fill Rate Shipping within 24 Hours State of the Art Warehouse System Technical Support Quality Control Program 25 Whaley Avenue Milverton, Ontario N0K
More informationPowermate Range Pitch 7.62
owermate Range itch 7.62 in headers Socket connectors CB connection Solder connection SV 7.62/90 500 V / 43 A SV 7.62/180 500 V / 41 A.2.4 Cable connection Clamping yoke connection Tension clamp connection
More informationInvue ECM/EMM EPIC MEDIUM 42-150W
DESCRIPTION The EPIC Collection delivers custom luminaire flexibility with the quality and availability expectations of standard specification grade product. Offered in two housing sizes and hundreds of
More informationPUSH-PULL CABLES CONTROL SYSTEMS
ISO 9001 CERTIFIED PUSH-PULL CABLES CONTROL SYSTEMS WESCON PRODUCTS COMPANY A subsidiary of LATSHAW ENTERPRISES, INC. WESCON'S PUSH-PULL CONTROL SYSTEMS Push-Pull Cable Ends Wescon Push-Pull Cable Assemblies
More informationCables. Accessories. For Force, Torque and Strain Sensors
Accessories Cables For Force, Torque and Strain Sensors Charge mode, high impedance piezoelectric measurement demands highly insulated coaxial cables and connectors to ensure an insulation resistance greater
More informationproduces and delivers products worldwide can provide the optimal are dedicated to supplying you with superior advice and global support.
www.ppcinsulators.com The very Best. The very Best. That s what we deliver. ong od Insulators Only a company that develops, produces and delivers products worldwide can provide the optimal solution for
More informationPW Cable Tray Ladder, Trough & Solid Bottom
PW Cable ray adder, rough & Solid Bottom Metallic Covers & Cover Connectors Covers protect and contain cables. hey are highly recommended to avoid damage to the tray contents and to protect against the
More informationFeed-through terminal block - SSK 110 KER-EX - 0502058
Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's documentation. Our General Terms of Use for Downloads are valid
More informationElectrical Code Regulation
Electrical Code Regulation St. Clair County has adopted the 2005 National Electrical Code in its entirety for the unincorporated areas of the county and all communities that have contracted with the county
More informationType 1, 3, & 3R Enclosures
Junction oxes Type 1 Screw over....................................................................... 50-53 Junction oxes Type 1 Hinge over........................................................................
More informationINSTALLATION OF A BAY WINDOW
INSTALLATION OF A BAY WINDOW Installation of a Bay Window These instructions relate to the replacement of an existing bay window or replacement of a straight window with a new bay window, in an opening
More informationNow Available in Black Zinc Nickel
847/848 Series Power Supply up to 63 Now vailable in lack Zinc Nickel The 847/848 bayonet Series has been especially designed for light and harsh environment. Its physical characteristics and performances
More informationStructural Bolting. Notice the Grade 5 has a much smaller head configuration and a shorter shank then the A325 structural bolt. Rev.
Structural Bolting ASTM A325 and ASTM A490 are the two U.S. standard structural bolts. When looking at the mechanical requirements of bolts it appears that an ASTM A325 and SAE J429 Grade 5 are identical
More informationSeries 8146/5-V37 and Series 8150/5-V37
www.stahl.de > Clear assignment safe technology easy installation > Intelligent structure only one rotary actuator for frequency-controlled drives ) 20 ms leading auxiliary contact for safe motor disconnection
More informationGAS DISTRIBUTION PRODUCTS STEEL SERVICE TEES
GAS DISTRIBUTION PRODUCTS STEEL SERVICE TEES CONTINENTAL INDUSTRIES ABOUT US THE ULTIMATE CONNECTION Our Company Continental Industries, headquartered in Tulsa, Oklahoma, was formed in 1958 and is today
More informationI N D U S T R I A L C A B L E G L A N D S
Introduction 1/2 Industrial Cable Gland W Industrial Cable Gland WL Heavy Duty Industrial Cable Gland CW Industrial Cable Gland CZ Industrial Cable Gland 1W Industrial Cable Gland 1Z Industrial Cable Gland
More informationQuick Connect. RTDs, Cordsets and Transmitter with M12 Connections
Quick Connect RTDs, Cordsets and Transmitter with M12 Connections 1 Temperature Measurement Experts Since 1960, urns Engineering has been an industry leader in the design and manufacture of temperature
More informationCat. No. Material Siderail Height. Designed to lock into place for easy alignment and installation. ABW-4-SSP
Metallic Snap-In Splice Plate Designed to lock into place for easy alignment and installation. Packaged in pairs with zinc plated hardware. Provided as standard with each straight and fitting. Cat. No.
More informationCable Trays Technical Instructions & Specifications
Cable Trays Technical Instructions & Specifications Products Catalogue Objective and Structure The company s main objective is the supply of quality products, with respect to: practical design increased
More informationDock Hardware & Accessory Products Catalog
Dock Hardware & Accessory Products Catalog Product Page # Product Page # Angle Brackets/Clips 8 Back Up Plate 5 Backing Plate/Hurricane Stop 10 Carriage Bolt Sets 4 Chain Retainer 10 Connector Pin Set
More informationGlenair Military and Industrial Power and Signal Connectors
Glenair Military and Industrial Power and Signal Connectors Series ITS (And FRITS) 5015 Type Reverse Bayonet Connectors Derived from MIL-DTL-5015 and VG95234 Mating mechanism (3 reverse bayonets at 120
More information33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application
33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application Features Compliant with the IEEE802.3at Standard -40 to +60 C Temperature Range Diagnostic LEDs Full Protection
More informationELECTRICAL GUIDELINES FOR SINGLE-FAMILY HOME OWNERS:
ELECTRICAL GUIDELINES FOR SINGLE-FAMILY HOME OWNERS: Chapter 12 of the Burlington Code of ordinances allows owner occupants of single family homes to do their own wiring if they choose. If you choose to
More informationControl Stations Made of Polyester Resin Series 8146
ontrol Stations Made of Polyester Resin www.stahl.de > s made of glass-fibre reinforced polyester resin > 8 basic enclosure sizes with various enclosure heights > an be combined to larger units > Equipped
More informationCopper and Aluminum busbars
Copper and Aluminum busbars Two metals are currently used as conductors in electric panel boards: copper and aluminum In particular, when in need to define a power distribution inside an electric panel
More information400 Series - Mini USB Buccaneer
IP68 Sealed IP68 rated USB V2.0 performance Plug and play capability Shielded system Overmoulded cables Screw coupling PCB versions Dust and waterproof to EN60529 Data rates up to 480Mbs Hot pluggable,
More informationStainless Steel and Mild Steel Enclosures. Stainless Steel and Mild Steel Enclosures
SX 8 The SX range comprises 14 sizes of enclosure manufactured in either stainless steel or mild steel. 11 sizes are available in depths of 140 or 200mm and 8 sizes are available in depths of 140, 200
More informationBUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS
BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS PLEASE READ COMPLETE INSTRUCTIONS BEFORE YOU BEGIN LEAVE INSTALLATION INSTRUCTIONS AND USER'S GUIDE WITH OWNER ALL ELECTRIC WIRING AND PLUMBING MUST BE DONE
More informationProduct Catalog. Lightning Protection UL Listed product range
Product Catalog Lightning Protection UL Listed product range Lightning Protection Furse UL Listed product range Introduction Conductors Air termination Through roof connectors Cable connectors, clamps
More information2014 NEC Guide Lines for Home Owner Doing Electrical Work on their Property
2014 NEC Guide Lines for Home Owner Doing Electrical Work on their Property A brief summary of the most used code references for residential wiring State of Idaho Division of Building Safety Electrical
More informationRPS - sales@rpssolar.com - 858 755 4505-12478 San Bruno Cove, San Diego, CA 92130
RPS - sales@rpssolar.com - 858 755 4505-2478 San Bruno Cove, San Diego, CA 9230 SWH Solar Mount Rail R-MR-SW-SR-0.5, R-MR-SW-SR-2, R-MR-SW-SR-4, R-MR-SW-SR-4B, R-MR-SW-SR-7 Part No. MR-SW-SR-0.5, MR-SW-SR-2,
More informationPARTS & SERVICE MANUAL for CONTEMPO SERIES WARMER LAMPS
PARTS & SERVICE MANUAL for CONTEMPO SERIES WARMER LAMPS Merco Contempo Warmer Lamps offer graceful, dramatic styling to match any décor. They are made of exacting tolerance from heavy duty, solid, mandrelspun
More informationGUARDRAIL POST STEEL
GUARDRAIL POST STEEL Guardrail posts meeting materials certification are evaluated and checked for: 1. Dimensional acceptance 2. Physical test results a. Chemical b. Physical 3. Galvanized or painted coating
More informationGeneral Specifications
Series M eneral Specifications Miniature Supplement ccessories Indicators Touch Tilt Tactiles Slides Rotaries Keylocks Programmable Illuminated PB Pushbuttons Rockers Electrical apacity (Resistive Load)
More informationOutdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points
Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points Features SELV Compliant No Detection Passive Injector Gigabit Compatible Full Protection
More informationPressure monitoring equipment for oil-sf 6. bushings, type GOEK
Pressure monitoring equipment for oil-sf 6 bushings, type GOEK Installation and maintenance guide 5693 827-6 en, Rev. 3, 2002-01-30 This document must not be copied without our written permission, and
More informationHose Clamps & Fittings
All Stainless Steel Marine or Underground Hose Clamps 5/16 HEX HEAD SCREW 60000 SERIES Highly corrosion resistant Use for marine or underground applications Stainless Steel Band, Housing Plated Steel Screw
More informationNEW SERVICE INSTALLATION STEPS. Common Slow Downs. Other Necessary Steps
NEW SERVICE INSTALLATION STEPS Here is the step-by-step process required to fulfill your service installation request. Please take a few minutes to review the steps, become familiar with key milestones
More informationOVERALL CONVEYOR WIDTH STEEL ALUMINUM MODEL # PER FT. 10 FT. 5 FT. PER FT. 10 FT. 5 FT. PER FT. 10 FT. 5 FT. PER FT. 10 FT. 5 FT.
Pick Smarter. Pick Better. Pick UNEX. Skatewheel (SW) Skatewheel Gravity Conveyor is ideally suited to convey lightweight packages and where operations require portable or temporary conveyor lines such
More informationSECTION 4: Cable Ladder Stainless Steel & Aluminium
SECTION 4: Cable Ladder & Aluminium Type 3/50 (NEMA 6A) Type 4/70L Type 5/112 (NEMA 20C) > 4:3 > 4:4 > 4:5 Aluminium Type 4/70A (NEMA 16B) Ladder Splice Plates > 4:7 > 3:18 Page 4:1 Cable Ladder General
More informationStainless Steel Cable Assemblies to Enhance Any Railing and Any View!
2014 Feeney (9/14) King Architectural Metals Stainless Steel Cable Assemblies to Enhance Any Railing and Any View! Standard Cable Assemblies Easy-to-install, prefabricated cable assemblies are an attractive,
More informationInterface RF Connector with Switch
NEW Interface RF onnector with Switch Series Overview Designed for end user applications requiring redirection of transmission from internal built-in antenna to the external antenna. Small size, lightweight
More informationPowers Controls Free Energy Band TH 193 HC Heating/Cooling Room Thermostat
Document No. 155-068P25 TH 193-4 Powers Controls Free Energy Band TH 193 HC Heating/Cooling Room Thermostat 50 60 70 80 70 TH0356R1 60 80 POWERS Description The TH 193 HC thermostats are proportional dual
More informationCABLE TRAY. Introduction
Introduction BLE TRAY ICMS cable tray system including Fittings and accessories is manufactured with return flange in a standard length of 2.44Mtr, according to the following specifications and standards:
More informationXL PREMIUM OIL COOLER KIT
-J05 REV. 0-0-0 XL PREMIUM OIL COOLER KIT GENERAL Kit Number 0008 Models For model fitment information, see the P&A Retail Catalog or the Parts and Accessories section of www.harley-davidson.com (English
More informationMagnesium TM. Soil Anodes. High Potential Magnesium. Production - Quality Control. Laboratory- Testing. Packaging- Availability
Magnesium TM Soil Anodes High Potential Magnesium SuperMag High Potential Magnesium Anodes from Galvotec Alloys, Inc. offers typical high workingldriving potentials of -1.70 volts or better vs. copperlcopper
More informationCable Accessories. for Extruded Dielectric Cable 69kV - 230kV Rated. Catalog Python13
Cable Accessories for Extruded Dielectric Cable 69kV - 230kV Rated Components used in cable systems 100% Tested Factory Molded For outdoor applications through 230kV For gas insulated substations and transformers
More informationEZ-48-3AB-125-35 Weather Station Mounting Tripod and Mast
EZ-48-3AB-125-35 Weather Station Mounting Tripod and Mast EZ-125-35M 35 Mast Extension (Optional) EZ-125-SK Stake Kit (Optional) EZ-46-3 Tar Pad Kit (Optional) EZ-GWA Guy Wire Kit (Optional) Ambient Weather
More informationPower cable compression lugs Installation of solderless compression lugs on power cables
Power cable compression lugs nstallation of solderless compression lugs on power cables 2 ompression lugs solutions A ompression power cable lugs solutions ontents olor-keyed System 4 HEX rimping Technology
More informationThere is no upside to. down time
EXPANDED and PERFORATED Data and Specifications 30 Similar to Type 302 with excellent mechanical properties, resistance to many corrosive agents. Useful where sanitation and cleanliness are important.
More informationContact-Systems and Accessories for Anodising and Electroplating Equipment
Contact-Systems and Accessories for Anodising and Electroplating Equipment 2000 Table of Contents Description Page High Current Contacts and Accessories for Rack Systems Contact Saddles Standard 250-3000
More informationCT-02 CABLE TRAY SYSTEMS
CT-02 CABLE TRAY SYSTEMS SYSTEMS THAT MAKE SENSE Introduction B-Line Systems was formed in 96 and has over 30 years experience manufacturing cable tray systems in which it has grown to become the industry
More informationSPECIFICATIONS FOR THE INSTALLATION OF FIRE ALARM SYSTEMS, SPRINKLER SYSTEMS, AND MASTER BOXES IN THE POQUONNOCK BRIDGE FIRE DISTRICT
SPECIFICATIONS FOR THE INSTALLATION OF FIRE ALARM SYSTEMS, SPRINKLER SYSTEMS, AND MASTER BOXES IN THE POQUONNOCK BRIDGE FIRE DISTRICT The purpose of these specifications is to insure that there are minimum
More informationAccessories for GF and RA machines
Orbital cutting & beveling machines for high-purity process piping www.orbitalum.com Accessories for GF and RA machines A brand of ITW Orbital Cutting & Welding 23 www.orbitalum.com Orbital cutting & beveling
More information08. SEK IDC CONNECTORS
. IDC CONNECTORS connectors for flat cables enable simple and, cost-optimized device configuration. connectors are preferably used for connection within the device. HARTING offers a broad range of these
More informationRAILWAY CATENARY SYSTEMS. Components and Systems for the Electrification of Railway Lines. ibemo
Connectors, Clamps, Compensating Devices, Insulators and Safety Equipment for Overhead Catenary Lines RAILWAY CATENARY SYSTEMS Components and Systems for the Electrification of Railway Lines. Welcome to
More information