1 1:20 Description comprehensive range of industrial plugs, connectors, socket outlets and appliance inlets. The products are designed to meet IE.309 and S EN offering a choice of IP44 splashproof or an IP67 watertight rating. The range offers remarkable impact strength by way of its PT housing. Outstanding temperature performance and good resistance to most chemicals make it ideal for the most arduous applications. ontact pins and sleeves are of solid brass with stainless steel springs to keep contacts free of dirt and to ensure constant contact pressure. Features Robust construction throughout. onvex cable seal and protector. Rounded end-packing won t snag or collect debris when dragged. Ergonomic design. Rounded corners with no sharp edges. Easier and better grip for connection and disconnection alibrated sleeves fit with stainless steel springs to maintain even contact pressure. Self cleaning contact surfaces. Top grade brass in all contact parts means no galvanic corrosion. over opens with a flick of your thumb or finger even with thick gloves on.

2 2:20 PLUGS D mps Pin V V V V V able Terminal onfig z 50-60z 50-60z 50-60z 50-60z Diameter D apacity uration List No List No List No List No List No min max sq. mm* 16 2P+E K9000 YEL 4 K9001 LU 6 K9002 RED P+E K9005 YEL 4 K9006 LU 9 K9007 RED 6 K9008 RED11 K9009 LK P+N+E K9013 YEL 4 K9014 LU 9 K9015 RED 6 K9016 RED P+E K9032 YEL 4 K9033 LU P+E K9035 YEL 4 K9036 LU 9 K9037 RED 6 K9038 RED11 K9039 LK P+N+E K9043 YEL 4 K9044 LU 9 K9045 RED 6 K9046 RED mps Pin. >50V >50V IS TRN >50-250V able *Terminal onfig z z 50-60z d.c. Diameter D apacity uration List No List No List No List No min max sq. mm 16 2P+E K9004 GRY 12 K9003 GRY P+E K9010 GRN10 K9011 GRN P+N+E K9017 GRN P+N+E K9047 GRN *flexible conductors PLUGS 63 MP FITTED WIT LE ENTRY GLND TRED SIZE M48 X 2 mps Pin V V able Terminal onfig z 50-60z Diameter D apacity uration List No List No min max sq. mm* 63 2P+E K9063 LU P+E K9065 LU 9 K9066 RED P+N+E K9071 RED D *flexible conductors PLUGS ELV mps Pin. 25V 50V 25 & 50V able Terminal onfig z 50-60z 50-60z Diameter apacity uration List No List No List No min max sq. mm* 16 2P K9018 VLT K9020 WI 12 K9022 WI and 2 x 6mm P K9019 VLT K9021 WI and 2 x 6mm 2 D Minor Key our Position *flexible conductors

3 3:20 PLUGS D mps Pin V V V able Terminal onfig z 50-60z 50-60z Diameter D apacity uration List No List No List No min max sq. mm* 16 2P+E K9023 YEL 4 K9024 LU P+E K9025 RED P+N+E K9026 RED P+E K9053 YEL 4 K9054 LU P+E K9055 RED P+N+E K9056 RED *flexible conductors PLUGS 63 ND 125 MP Dmax mps Pin V V V V V able Terminal onfig z 50-60z 50-60z 50-60z 50-60z Diameter apacity uration List No List No List No List No List No min max sq. mm* 63 2P+E K9294 YEL 4 K9298 LU P+E K9282 RED 6 K9283 RED11 K9284 LK P+N+E K9292 RED 6 K9293 RED P+E K9099 LU P+E K9092 RED 6 K9093 RED P+N+E K9097 RED D max *flexible conductors

4 4:20 ONNETORS D mps Pin V V V V V able Terminal onfig z 50-60z 50-60z 50-60z 50-60z Diameter D apacity uration List No List No List No List No List No min max sq. mm* 16 2P+E K9100 YEL 4 K9101 LU 6 K9102 RED P+E K9105 YEL 4 K9106 LU 9 K9107 RED 6 K9108 RED 11 K9109 LK P+N+E K9113 YEL 4 K9114 LU 9 K9115 RED 6 K9116 RED P+E K9132 YEL 4 K9133 LU P+E K9135 YEL 4 K9136 LU 9 K9137 RED 6 K9138 RED 11 K9139 LK P+N+E K9142 YEL 4 K9143 LU 9 K9144 RED 6 K9145 RED mps Pin. >50V >50V IS TRN >50-250V able *Terminal onfig z z 50-60z d.c. Diameter D apacity uration List No List No List No List No min max sq. mm 16 2P+E K9104 GRY 12 K9103 GRY P+E K9110 GRN 10 K9111 GRN P+N+E K9117 GRN P+N+E K9146 GRN *flexible conductors ONNETORS 63 MP FITTED WIT LE ENTRY GLND TRED SIZE M48 X 2 D mps Pin V V able Terminal onfig z 50-60z Diameter D apacity uration List No List No min max sq. mm* 63 2P+E K9172 LU P+E K9164 LU 9 K9165 RED P+N+E K9170 RED *flexible conductors ONNETORS ELV mps Pin. 25V 50V 25 & 50V able Terminal onfig z 50-60z 50-60z Diameter apacity sq. mm uration List No List No List No min max (flexible conductors) 16 2P K9118 VLT K9120 WI 12 K9122 WI and 2 x 6mm P K9119 VLT K9121 WI and 2 x 6mm 2 D Minor Key our Position

5 5:20 ONNETORS D mps Pin V V V able Terminal onfig z 50-60z 50-60z Diameter apacity uration List No List No List No min max sq. mm* 16 2P+E K9123 YEL 4 K9124 LU P+E K9125 RED P+N+E K9126 RED P+E K9155 YEL 4 K9156 LU P+E K9157 RED P+N+E K9158 RED D max *flexible conductors ONNETORS 63 ND 125 MP Dmax mps Pin V V V V V able Terminal onfig z 50-60z 50-60z 50-60z 50-60z Diameter apacity uration List No List No List No List No List No min max sq. mm* 63 2P+E K9855 YEL 4 K9856 LU P+E K9842 RED 6 K9843 RED11 K9844 LK P+N+E K9852 RED 6 K9853 RED P+E K9189 LU P+E K9182 RED 6 K9183 RED P+N+E K9187 RED D max *flexible conductors

6 6:20 NGLED SURFE MOUNTING TOP ONDUIT OR RER LE ENTRY, OMPLETE WIT LNKING PLUG E 1 øf G mps Pin V V V V V Terminal onfig z 50-60z 50-60z 50-60z 50-60z apacity uration List No List No List No List No List No sq. mm* 16 2P+E K9200 YEL 4 K9201 LU 6 K9202 RED P+E K9205 YEL 4 K9206 LU 9 K9207 RED 6 K9208 RED 11 K9209 LK P+N+E K9213 YEL 4 K9214 LU 9 K9215 RED 6 K9216 RED P+E K9232 YEL 4 K9233 LU P+E K9235 YEL 4 K9236 LU 9 K9237 RED 6 K9238 LK P+N+E K9239 YEL 4 K9240 LU 9 K9241 RED 6 K9242 RED Top onduit Rear Entry entry 1 E F D G M20 Ø M20 Ø M20 Ø M25 Ø M25 Ø M25 Ø29 mps Pin. >50V >50V IS TRN >50-250V Terminal onfig z z 50-60z d.c. apacity uration List No List No List No List No sq. mm* 16 2P+E K9204 GRY 12 K9203 GRY P+E K9210 GRN 10 K9211GRN P+N+E K9252 GRN P+N+E K9258 GRN onduit Rear Entry Entry 1 E F D G M20 Ø M20 Ø M20 Ø M25 Ø29 NGLED SURFE MOUNTING 63 MP E 1 ø5.2 TOP ONDUIT OR RER LE ENTRY, OMPLETE WIT LNKING PLUG mps Pin V V Terminal onfig z 50-60z apacity uration List No List No sq. mm* 63 2P+E K9274 LU P+E K9264 LU 9 K9265 RED P+N+E K9269 RED onduit Rear Entry Entry mm 1 E D G M32 Ø M32 Ø M32 Ø35 NGLED SURFE MOUNTING ELV mps Pin. 25V 50V 25 & 50V Terminal onfig z 50-60z 50-60z apacity sq. mm* uration List No List No List No 16 2P K9253 VLT K9255 WI 12 K9257 WI and 2 x 6mm P K9254 VLT K9256 WI and 2 x 6mm 2 D F onduit Entry M M25 Minor Key our Position

7 7:20 NGLED SURFE MOUNTING 63 MP mps Pin V V Terminal onfig z 50-60z apacity uration List No List No sq. mm* 63 2P+E K9857 LU P+E K9858 RED P+N+E K9859 RED E F G STRIGT PNEL MOUNTING 1 LL FLNGES VE TE SME FIXING ENTRES ND OUTSIDE DIMENSIONS TO SSIST PNEL UILDING. SEE ELOW FOR MINIMISED FLNGE OPTION. ø4.2 E1 E mps Pin V V V V Terminal onfig z 50-60z 50-60z 50-60z apacity uration List No List No List No List No sq. mm * 16 2P+E K9400 YEL 4 K9401 LU P+E K9405 YEL 4 K9406 LU 9 K9407 RED P+N+E K9413 YEL 4 K9414 LU 9 K9415 RED 6 K9416 RED P+E K9432 YEL 4 K9433 LU P+E K9435 YEL 4 K9437 RED P+N+E K9444 LU 9 K9445 RED 6 K9446 RED D E E mps Pin. >50V >50V IS TRN >50-250V Terminal onfig z z 50-60z d.c. apacity uration List No List No List No List No sq. mm * 16 2P+E K9404 GRY 12 K9403 GRY P+E K9410 GRN 10 K9411 GRN P+N+E K9417 GRN P+N+E K9447 GRN D E E MINIMISED FLNGE FOR STRIGT PNEL MOUNTING 16 MP OUTLETS NOTE: FIXING ENTRES OMPTILE WIT NON K SERIES PRODUT 1 mps Pin. onfiguration 16 2P+E K P+E, 3P+N+E K D ø4.2 Minimised flange can be used to replace flange supplied with straight panel mounted outlets. To be ordered as additional part.

8 8:20 NGLED PNEL MOUNTING ELV mps Pin. 25V 50V 25 & 50V Terminal onfig z 50-60z 50-60z apacity sq. mm* uration List No List No List No 16 2P K9518 VLT K9520 WI 12 K9522 WI and 2 x 6mm P K9519 VLT K9521 WI and 2 x 6mm 2 D E1 E2 F1 F2 G max Minor Key our Position STRIGT PNEL MOUNTING 63 MP mps Pin V V Terminal onfig z 50-60z apacity uration List No List No sq. mm * 1 D E E1 ø P+E K9472 LU P+E K9465 RED P+N+E K9470 RED E1 E NGLED PNEL MOUNTING mps Pin V V V Terminal onfig z 50-60z 50-60z apacity uration List No List No List No sq. mm* 16 2P+E K9802 YEL 4 K9803 LU D E E P+E K9807 RED P+N+E K9815 RED P+E K9865 YEL 4 K9866 LU P+E K9870 RED ø5 E1 E 32 3P+N+E K9873 RED NGLED PNEL MOUNTING 63 MP 1 mps Pin V V Terminal onfig z 50-60z apacity uration List No List No sq. mm* 63 2P+E K9825 LU D E E P+E K9582 RED P+N+E K9592 RED ø4.2 E1 E

9 9:20 STRIGT PNEL MOUNTING 63 ND 125 MP mps Pin V V Terminal onfig z 50-60z apacity uration List No List No sq. mm* 1 D E E1 ø4.2/ P+E K9828 LU P+E K9812 RED P+N+E K9822 RED P+E K9483 LU E1 E 125 3P+E K9481 RED P+N+E K9482 RED NGLED PNEL MOUNTING IP44 Outlet ngled Panel Mounted can be installed in two ways, recessed (option ) or protruding (Option ). The flange is supplied loose to enable installer to select option at time of installation. NOTE: with option terminations must be made prior to mounting outlet to flange. 1 ø4.2 1 Option E1 E 1 1 ø4.2 Option E1 E mps Pin V V V V Terminal onfig z 50-60z 50-60z 50-60z apacity uration List No List No List No List No sq. mm* 16 2P+E K9500 YEL 4 K9501 LU 6 K9502 RED P+E K9506 LU 9 K9507 RED 6 K9508 RED P+N+E K9514 LU 9 K9515 RED 6 K9516 RED P+E K9532 YEL 4 K9533 LU P+E K9538 RED 6 K9539 RED P+N+E K9542 LU 9 K9543 RED mps Pin. >50V >50V IS TRN >50-250V Terminal onfig z z 50-60z d.c. apacity uration List No List No List No List No sq. mm* 16 2P+E K9504 GRY P+E K9510 GRN Option 1 D E E Option 1 D E E Option 1 D E E Option 1 D E E NGLED PNEL MOUNTING 63 MP mps Pin V V Terminal onfig z 50-60z apacity uration List No List No sq. mm* 63 2P+E K9544 LU D E E P+E K9565 RED P+N+E K9570 RED M4 E1 E

10 10:20 SWIT NGLED SURFE MOUNTING 16 MP mps Pin V V V Terminal onfig z 50-60z 50-60z apacity uration List No List No List No sq. mm* 16 2P+E K9912 YEL 4 K9914 RED P+E K9919 LU 9 K9920 RED UTILISTION TEGORY 22 With two x M20 x 1.5mm *Solid or Stranded conductors threaded conduit entries and one x 18mm knockout in both top and bottom. Supplied with blanking plugs/cable entry D E F Fixing entres x x 95 SWIT INTERLOKED NGLED FLNGE ENTRY SURFE MOUNTING 16, 32 ND 63 MP LUMINIUM LLOY ENLOSURE. 16 amp and 32 amp Supplied with FL9 flange and gland plates Will accept auxiliary contact eg and amp Supplied with FL13 flange and gland plates Will accept auxiliary contact 6801 and 6802 Switch can be locked in open or closed position. Switch Utilisation ategory 22 mps Pin V V V V V >50V Terminal onfig z 50-60z 50-60z 50-60z 50-60z > z apacity uration List No List No List No List No List No List No sq. mm* 16 3P+E K9600 YEL 4 K9601 LU 9 K9602 RED 6 K9603 RED 11 K9604 LK 7 K9605 GRN P+N+E K9606 YEL 4 K9607 LU 9 K9608 RED P+E K9632 YEL 4 K9633 LU 9 K9634 RED 6 K9635 RED 11 K9636 LK P+N+E K9638 YEL 4 K9639 LU 9 K9640 RED 6 K9641 RED P+E K9664 LU 9 K9665 RED P+N+E K9670 RED Fixing FL entres x x x x x x SWIT INTERLOKED NGLED ONDUIT ENTRY SURFE MOUNTING 16, 32 ND 63 MP 16 amp and 32 amp With 29mm knockout at top. Will accept FL13 flange. ottom conduit entry supplied with PG21 to M25 x 1.5 daptor. 63 amp FL13 flange entry at top. Supplied with cover plate and gland plate. Will accept auxiliary contact 6801 and 6802 Switch Utilisation ategory 22 mps Pin V V V Terminal onfig z 50-60z 50-60z apacity uration List No List No List No sq. mm* 16 2P+E K9609 YEL 4 K9610 LU P+E K9611 RED P+N+E K9612 RED P+E K9642 YEL 4 K9643 LU P+E K9644 RED P+N+E K9645 RED P+E K9306 LU P+E K9311 LU 9 K9312 RED Fixing onduit entres Entry D x 91 pg21* x 91 pg21* x 91 pg21* x 91 pg21* x 91 pg21* x 91 pg21* x x 32mm x x 32mm 63 3P+N +E K9322 RED x x 32mm * fitted with M25 adaptor

11 11:20 SWIT INTERLOKED NGLED FLNGE ENTRY SURFE MOUNTING 16, 32 ND 63 MP 16 amp and 32 amp With 29mm knockout at top. Will accept FL13 flange. ottom conduit entry supplied with PG21 to M25 x 1.5 daptor. 63 amp With 32mm knockouts top and bottom.will accept FL13 flange top and bottom.will accept auxiliary contact 6801 and 6802 Switch can be locked in open position. In closed position by removing tab.switch Utilisation ategory 22 mps Pin V V V V V Terminal onfig z 50-60z 50-60z 50-60z 50-60z apacity uration List No List No List No List No List No sq. mm * 16 2P+E K9324 LU P+E K9327 RED P+N+E K9330 RED P+E K9369 LU P+E K9359 RED P+N+E K9362 RED P+E K9356 YEL 4 K9355 LU P+E K9342 RED 6 K9343 RED 11 K9344 LK P+N+E K9352 RED 6 K9353 RED Fixing onduit entres Entry x 91 pg 21* x 91 pg 21* x 91 pg 21* x 91 pg 21* x 91 pg 21* x 91 pg 21* x x 32mm x x 32mm x x 32mm *Fitted with M25 adaptor PPLINE INLETS NGLED SURFE MOUNTING TOP ONDUIT OR RER LE ENTRY, OMPLETE WIT LNKING PLUG 1 øf G mps Pin V V V V able Terminal onfig z 50-60z 50-60z 50-60z Diameter apacity uration List No List No List No List No min max sq. mm* 16 2P+E K9700 YEL 4 K9701 LU P+E K9706 RED 6 K9707 LK P+N+E K9709 YEL 4 K9710 LU 9 K9711 RED P+E K9732 YEL 4 K9733 LU P+E K9736 RED 6 K9737 LK Top Rear onduit Entry 1 E1 F I Entry D G M20 Ø M20 Ø M20 Ø M25 Ø M25 Ø P+N+E K9740 LU 9 K9741 RED M25 Ø29 E1 PPLINE INLETS NGLED SURFE MOUNTING 63MP mps Pin V V able Terminal onfig z 50-60z Diameter apacity uration List No List No min max sq. mm* 63 2P+E K9775 LU P+N+E K9768 RED onduit Rear Entry Entry F E mm Ø mm Ø35

12 12:20 PPLINE INLETS NGLED SURFE MOUNTING 63 MP mps Pin V V Terminal onfig z 50-60z apacity uration List No List No sq. mm* 63 2P+E K9826 LU P+E K9829 RED P+N+E K9827 RED E onduit Entry 2 x 29/37mm and 1 x 23mm top 1 x 29/37mm and 2 x 23mm knockouts bottom Will accept FL13 Flange top and bottom PPLINE INLETS SURFE MOUNTING 125 MP mps Pin V V Terminal onfig z 50-60z apacity uration List No List No sq. mm* onduit Entry P+E K9883 LU x 23/47mm top and bottom 125 3P+N+E K9884 RED x 23/47mm top and bottom PPLINE INLETS NGLED PNEL MOUNTING 16, 32, 63 ND 125 MP mps Pin V V V Terminal onfig z 50-60z 50-60z apacity uration List No List No List No sq. mm* 16 2P+E K9780 YEL 4 K9781 LU P+E K9782 RED P+N+E K9783 RED P+E K9784 YEL 4 K9785 LU P+E K9786 RED P+N+E K9787 RED P+E K9788 YEL 4 K9789 LU P+E K9790 RED P+N+E K9791 RED P+E K9792 LU P+N+E K9793 RED D E3 E ø5 E3 E4 63 ND 125 MP ø4.2 E4 E3

13 13:20 PPLINE INLETS SURFE MOUNTING ELV mps Pin. 25V Terminal onfig z apacity sq. mm * uration List No (flexible conductors) 16 2P K9725 VLT 4-10 and 2 x 6mm P K9726 VLT 4-10 and 2 x 6mm 2 D E F onduit Entry M M25 TREE WY DPTOR 16 MP mps Pin V V V onfig z 50-60z 50-60z uration List No List No List No 16 2P+E K9907 YEL 4 K9908 LU P+E K9910 RED P+N+E K9911 RED 6 D LOOP IN SURFE MOUNTING mps Pin V V V able Entry *Terminal Fixing onfig z 50-60z 50-60z Knockouts apacity entres uration List No List No List No sq. mm* mm 16 2P+E K13200 YEL 4 K13201 LU 6 2 x Ø25 top 2 x (1.5-10) 90 x ø29x2 Ø25x2 16 3P+E K13207 RED 6 2 x Ø25 top 2 x (1.5-10) 90 x P+N+E K13215 RED 6 2 x Ø25 top 2 x (1.5-10) 90 x P+E K13232 YEL 4 K13233 LU 6 2 x Ø25 top 2 x (2.5-10) 90 x P+E K13237 RED 6 2 x Ø25 top 2 x (2.5-10) 90 x P+N+E K13241 RED 6 2 x Ø25 top 2 x (2.5-10) 90 x

14 14:20 SWIT INTERLOKED SURFE MOUNTING (SUITLE FOR TOP ENTRY) Switch Utilisation ategory 22 Will accept auxiliary contacts 6813 and 6814 Switch can be locked in open position. In closed position by removing tab. mps Pin V V V able Entry Terminal Fixing onfig z 50-60z 50-60z Knockouts apacity entres uration List No List No List No sq. mm* mm Ø25x2 ø29x2 16 2P+E K13600 YEL 4 K13601 LU 6 2 x Ø25 top x P+E K13607 RED 6 2 x Ø25 top x P+N+E K13615 RED 6 2 x Ø25 top x P+E K13632 YEL 4 K13633 LU 6 2 x Ø25 top x P+E K13637 RED 6 2 x Ø25 top x P+N+E K13641 RED 6 2 x Ø25 top x SWIT INTERLOKED SURFE MOUNTING Switch Utilisation ategory 22 Will accept auxiliary contacts 6813 and 6814 Switch can be locked in open position. In closed position by removing tab. mps Pin V V V able Entry Terminal Fixing onfig z 50-60z 50-60z Knockouts apacity entres uration List No List No List No sq. mm* mm 16 2P+E K13623 YEL 4 K13624 LU 6 2 x Ø25 top x ø29x2 Ø25x2 16 3P+E K13625 RED 6 2 x Ø25 top x P+N+E K13626 RED 6 2 x Ø25 top x P+E K13653 YEL 4 K13654 LU 6 2 x Ø25 top x P+E K13655 RED 6 2 x Ø25 top x P+N+E K13656 RED 6 2 x Ø25 top x SWIT INTERLOKED SURFE MOUNTING 125 MP Switch Utilisation ategory 22 Will accept auxiliary contacts 6813 and 6814 Switch can be locked in open position. In closed position by removing tab. mps Pin V V V able Entry Terminal onfig z 50-60z 60z Knockouts apacity uration List No List No List No sq. mm* P+E K9688 LU 6 2 x 23/47mm top and bottom P+E K9691 RED 6 K9692 RED 11 2 x 23/47mm top and bottom P+N+E K9694 RED 6 2 x 23/47mm top and bottom *Solid or Stranded onductors 204

15 15:20 SURFE MOUNTING SUITLE FOR TOP ENTRY mps Pin V V V Terminal able Entry Fixing onfig z 50-60z 50-60z apacity Knockouts entres uration List No List No List No sq. mm* mm 16 2P+E K9196 YEL 4 K9197 LU x Ø25 top 90 x P+E K9198 RED x Ø25 top 90 x P+N+E K9199 RED x Ø25 top 90 x P+E K9259 YEL 4 K9260 LU x Ø25 top 90 x P+E K9261 RED x Ø25 top 90 x P+N+E K9262 RED x Ø25 top 90 x Ø25x2 ø29x2 149 LOOP IN VERSIONS Fitted with terminals for Loop In mps Pin V V V Terminal able Entry Fixing onfig z 50-60z 50-60z apacity Knockouts entres uration List No List No List No sq. mm* mm 16 2P+E K13023 YEL 4 K13024 LU 6 2 x (1.5-10) 2 x Ø25 top 90 x P+E K13025 RED 6 2 x (1.5-10) 2 x Ø25 top 90 x P+N+E K13026 RED 6 2 x (1.5-10) 2 x Ø25 top 90 x P+E K13053 YEL 4 K13054 LU 6 2 x (2.5-10) 2 x Ø25 top 90 x P+E K13055 RED 6 2 x (2.5-10) 2 x Ø25 top 90 x P+N+E K13056 RED 6 2 x (2.5-10) 2 x Ø25 top 90 x 171 LOOP IN SURFE MOUNTING 125 MP mps Pin V V V able Entry Terminal onfig z 50-60z 60z Knockouts apacity uration List No List No List No sq. mm* 125 2P+E K9190 LU 6 2 x 23/47mm top & bottom 2 x (16-70) 125 3P+E K9191 RED 6 K9195 RED 11 2 x 23/47mm top & bottom 2 x (16-70) 125 3P+N+E K9194 RED 6 2 x 23/47mm top & bottom 2 x (16-70) *Solid or Solid Stranded conductors

16 ombination Unit 16:20 SINGLE PRE-WIRED WIT 30m RD 171 RD Earth mps Pin V V V Terminal apacity Terminal apacity able Entry onfig z 50-60z 50-60z sq. mm* sq. mm Knockouts uration List No List No List No min max min max 16 2P+E K13413 YEL 4 K13414 LU x Ø25 top 16 3P+E K13415 RED x Ø25 top 16 3P+N+E K13416 RED x Ø25 top 32 2P+E K13433 LU x Ø25 top 32 3P+E K13434 RED x Ø25 top 32 3P+N+E K13435 RED x Ø25 top SWIT INTERLOKED PRE-WIRED WIT 30m RD RD Earth mps Pin V V V Terminal apacity Terminal apacity able Entry onfig z 50-60z 50-60z sq. mm* sq. mm Knockouts uration List No List No List No min max min max 16 2P+E K13309 YEL 4 K13310 LU x Ø25 top 16 3P+E K13311 RED x Ø25 top 16 3P+N+E K13312 RED x Ø25 top 32 2P+E K13342 YEL 4 K13343 LU x Ø25 top 32 3P+E K13344 RED x Ø25 top 32 3P+N+E K13345 RED x Ø25 top

17 ombination Unit 17:20 SINGLE PRE-WIRED WIT 30m RD RD Earth mps Pin V V V Terminal apacity Terminal apacity able Entry onfig z 50-60z 50-60z sq. mm* sq. mm Knockouts uration List No List No List No min max min max 16 2P+E K13713 YEL 4 K13714 LU x Ø25 top 16 3P+E K13715 RED x Ø25 top 16 3P+N+E K13716 RED x Ø25 top 32 2P+E K13733 LU x Ø25 top 32 3P+E K13734 RED x Ø25 top 32 3P+N+E K13735 RED x Ø25 top SWIT INTERLOKED PRE-WIRED WIT 30m RD RD Earth mps Pin V V V Terminal apacity Terminal apacity able Entry Fixing onfig z 50-60z 50-60z sq. mm* sq. mm Knockouts entres uration List No List No List No min max min max 16 2P+E K13346 YEL 6 K13348 LU x Ø25 top 100 x P+E K13350 RED x Ø25 top 100 x P+N+E K13351 RED x Ø25 top 100 x P+E K13347 YEL 6 K13349 LU x Ø25 top 100 x P+E K13352 RED x Ø25 top 100 x P+N+E K13353 RED x Ø25 top 100 x 290

18 Modular ombi 18:20 MODULR OMI UNITS TWIN SURFE SOKET OUTLET mps Pin V V Terminal apacity able Entry onfig z 50-60z sq mm* Knockouts uration List No List No min max Top ottom 16 2P+E K13143 YEL 4 K13144 LU 6 PREWIRED x Ø x Ø38 3 x Ø P+E K13043 YEL 4 K13044 LU 6 UNWIRED x Ø x Ø38 3 x Ø47.5 MODULR OMI UNITS TRIPLE SURFE SOKET OUTLET WIT SINGLE 30m RD PROTETION 16 MP RD Earth mps Pin V V Terminal apacity Terminal apacity able Entry onfig z 50-60z sq mm* sq mm Knockouts uration List No List No min max min max Top ottom 16 2P+E K13193 YEL 4 K13194 LU x Ø x Ø38 3 x Ø47.5

19 Modular ombi 19:20 MODULR OMI UNITS TWIN SURFE SOKET OUTLET WIT INDIVIDUL 30m RD PROTETION with 16 outlets (2P+E) with 16 (3P+E, 3P+N+E) and 32 outlets (2P+E, 3P+E, 3P+N+E) RD Earth mps Pin V V V Terminal apacity Terminal apacity able Entry onfig z 50-60z 50-60z sq mm* sq mm Knockouts uration List No List No List No min max min max Top ottom 16 2P+E K13173 YEL 4 K13174 LU x Ø x Ø38 3 x Ø P+E K13175 RED x Ø x Ø38 3 x Ø P+N+E K13176 RED x Ø x Ø38 3 x Ø P+E K13184 LU x Ø x Ø38 3 x Ø P+E K13185 RED x Ø x Ø38 3 x Ø P+N+E K13186 RED x Ø x Ø38 3 x Ø47.5 SINGLE PRE-WIRED WIT 30m RD 63 MP with 2P+E outlets with 3P+E and 3P+N+E outlets RD Earth mps Pin V V Terminal apacity Terminal apacity able Entry onfig z 50-60z sq. mm* sq. mm Knockouts uration List No List No min max min max Top ottom 63 2P+E K13463 LU x Ø25/2 x Ø38 3 x Ø P+E K13464 RED x Ø25/2 x Ø38 3 x Ø P+N+E K13465 RED x Ø25/2 x Ø38 3 x Ø47.5

20 Modular ombi 20:20 OMI LOKS TREE WY 16 MP mps Pin V V *Terminal able Dimensions onfig z 50-60z apacity Diameter in mm uration List No List No sq.mm min max D E F 16 2P+E OMI LOKS TWO WY 16 MP IP 56 SPLSPROOF mps Pin V V *Terminal able Dimensions onfig z 50-60z apacity Diameter in mm uration List No List No sq.mm min max D E F 16 2P+E OMI LOKS TWO WY 30m RD PROTETED 16 MP mps Pin V V *Terminal able Dimensions onfig z 50-60z apacity Diameter in mm uration List No List No sq.mm min max D E F 16 2P+E

Commando Technical. plugs 16 and 32 amp. plugs 63 amp. plugs elv. www.mkelectric.co.uk. wiring devices ingress protected C A

Commando Technical. plugs 16 and 32 amp. plugs 63 amp. plugs elv. www.mkelectric.co.uk. wiring devices ingress protected C A 641 ommando Technical wiring devices ingress protected www.mkelectric.co.uk plugs 16 and 32 amp mps Pin. 100-130V 200-250V 380-415V 440-460V 480-500V able Terminal onfig- 50-60Hz 50-60Hz 50-60Hz 50-60Hz

More information

Masterseal Plus TM. ingress protected wiring devices. technical hotline +44 (0) 1268 563720. www.mkelectric.com IP66. Improved catch.

Masterseal Plus TM. ingress protected wiring devices. technical hotline +44 (0) 1268 563720. www.mkelectric.com IP66. Improved catch. Masterseal Plus TM technical hotline +44 (0) 268 63720 Improved catch Rear drill holes Available in grey, white and black Fixed gasket speds installation gasket Now has all the features and logic plus

More information

14 PHOENIX CONTACT Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108. info@powermation.com - 800-843-9859 - www.powermation.

14 PHOENIX CONTACT Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108. info@powermation.com - 800-843-9859 - www.powermation. 14 PHOENIX CONTACT PLUSCON circular is a circular connector for use in industrial automation. The range of design sizes available is varied, starting with the design sizes M5 to M8 and M1, for sensor/actuator

More information

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv) Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv) Order code Series and function 1) Plug socket see page 5.042. MN-06-310-HN-442 Standard coil 1) 441 = 12 V DC, 4.2 W 442 = 24 V DC,

More information

SHOWERS 85-100 SHOWERS

SHOWERS 85-100 SHOWERS SHOWERS 85-100 85 SHOWERS SHOWER HEADS 87 NEPTUNE 89 SHOWER PANEL SERIES PERFECT TIME SHOWER PANEL SERIES 91 NEPTUNE 1042T 93 PERFECT TIME 1042T 94 NEPTUNE MEDICAL 95 TOUCH SH 1000T 96 NEPTUNE 1032 97

More information

Now Available in Black Zinc Nickel

Now Available in Black Zinc Nickel 847/848 Series Power Supply up to 63 Now vailable in lack Zinc Nickel The 847/848 bayonet Series has been especially designed for light and harsh environment. Its physical characteristics and performances

More information

Mini USB and USB 2.0-IP67 Connector System

Mini USB and USB 2.0-IP67 Connector System Mini USB and USB 2.0-IP67 Connector System Section 12 Mini USB and USB 2.0-IP67 Connector System CONEC has added the Mini-USB connector. This Mini-USB IP67 receptacle and plug family, feature a bayonet

More information

Industrial Plugs and Sockets. RCD Protected Combination Units BS EN.60309-2/BS4343:1992. including

Industrial Plugs and Sockets. RCD Protected Combination Units BS EN.60309-2/BS4343:1992. including Industrial Plugs and Sockets BS EN.030-2/BS33:12 including RCD Protected Combination Units Industrial Plugs & Sockets for harsh conditions & environments Chemical & Heavy Industry Building & Construction

More information

IEC Connectors. Introduction

IEC Connectors. Introduction Introduction IEC Connectors A full range of quality mains rated inlets, outlets and connectors conforming to IEC and EN 60320 specifications carrying UL, CSA, VDE and other approvals. With electrical ratings

More information

Standard Buccaneer - Ethernet

Standard Buccaneer - Ethernet IP6 rated compliant PUR jacket on cable Shielded system shielded coupler Shroud on RJ45 Screw coupling Rewireable flex connector PCB mounted panel connector IDC termination panel connector Earth lead version

More information

IEC 309 INTERLOCKS NORTH AMERICAN

IEC 309 INTERLOCKS NORTH AMERICAN IEC 309 INTERLOCKS NORTH AMERICAN SWITCH VERSION with MCB (Circuit Breakers) 20, 30, 60 Amp NEMA 4X Watertight (IP67) Drawing A (See Drawing on Specification Page) 20, 30, 60 Amp Spashproof (IP44) Drawing

More information

Series 8146/5-V37 and Series 8150/5-V37

Series 8146/5-V37 and Series 8150/5-V37 www.stahl.de > Clear assignment safe technology easy installation > Intelligent structure only one rotary actuator for frequency-controlled drives ) 20 ms leading auxiliary contact for safe motor disconnection

More information

AMPSEAL* Automotive Plug Connector and Header Assembly

AMPSEAL* Automotive Plug Connector and Header Assembly AMPSEAL* Automotive Plug Connector and Header Assembly Application Specification 24 SEP 97 Rev E All dimensions are given in millimeters unless otherwise specified. All dimensional tolerances are +0.2

More information

New Media Power Socket Outlets. New Media Power Socket Outlets

New Media Power Socket Outlets. New Media Power Socket Outlets New Media Power Socket Outlets The New Media Modules offer a flexible build solution to a host of individual power socket outlet requirements. The clip fit grid modules are simple to install in their blank

More information

A sophisticated design for a demanding field. prima series

A sophisticated design for a demanding field. prima series A sophisticated design for a demanding field prima series 2 nd edition 2003 prima compact horizontal interlocked sockets carefully studied A size for all versions with or without fuses. Extends horizontally

More information

DBS720 / FDS221-R / FDS221-W Sounder base, Alarm sounders

DBS720 / FDS221-R / FDS221-W Sounder base, Alarm sounders DBS720 / FDS221-R / FDS221-W Sounder base, Alarm sounders For the automatic addressable detector bus C-NET Cerberus PRO Sounder base DBS720 11 selectable tones, 2 programmable activation levels Sound intensity

More information

Sealed Industrial Ethernet Circular IP67 Cat. 5e RJ45 Connector System

Sealed Industrial Ethernet Circular IP67 Cat. 5e RJ45 Connector System Revised Sept--22-2009 Sealed Industrial Ethernet Circular IP67 Cat. 5e RJ45 Connector System Description The sealed circular RJ45 connector system is designed for use in harsh environments. The connector

More information

HARTING Ethernet Cabling 4-poles Overview

HARTING Ethernet Cabling 4-poles Overview Ethernet Cabling 4-poles Overview RJ45 Connectors [on page 8] System cables [on page 10] Distribution modules and Outlets [on page 20] Connectors [on page 22] System cables [on page 24] Panel feed-throughs

More information

Switches SWITCHES SWITCHES

Switches SWITCHES SWITCHES Switches Manufactured from Stainless Steel, Bulgin s extensive range of vandal resistant security switches are designed with a high resistance to wear and tear, corrosion and harsh use in potentially hostile

More information

6000 Series Buccaneer

6000 Series Buccaneer Robust, instant connections for harsh environments 6000 Series Buccaneer - circular connectors that combine the ease of use of a push/pull coupling mechanism with proven environmental sealing. Available

More information

Quick Connect Boxes Inside Gloveboxes

Quick Connect Boxes Inside Gloveboxes ULC Series Junction Boxes Quick Connect Boxes Inside Gloveboxes The ULC quick connect junction boxes are the essential elements to optimize the cabling inside gloveboxes. Large range Designed for nuclear

More information

Linear Luminaire for Fluorescent Lamps Series EXLUX 6001

Linear Luminaire for Fluorescent Lamps Series EXLUX 6001 > As wall, ceiling and pendant light fitting or side entry lamp > Version with 2 lamps: 18 W, 36 W and 58 W > Central locking > All-pole disconnection by means of an N/C switch when the lamp is opened

More information

Industrial circular connectors

Industrial circular connectors Industrial circular connectors M 16 M 58 010 CONINVERS - M16 to M58 circular connectors for industrial applications CONINVERS GmbH, an independent company, is the specialist for M16 to M58 circular connectors

More information

HARTING Ethernet Cabling 8-poles Overview

HARTING Ethernet Cabling 8-poles Overview Ethernet Cabling 8-poles Overview RJ45 Connectors [on page 8] System cables [on page 12] Distribution modules and Outlets [on page 17] Connectors [on page 20] System cables [on page 26] Panel feed-throughs

More information

400 Series - Mini USB Buccaneer

400 Series - Mini USB Buccaneer IP68 Sealed IP68 rated USB V2.0 performance Plug and play capability Shielded system Overmoulded cables Screw coupling PCB versions Dust and waterproof to EN60529 Data rates up to 480Mbs Hot pluggable,

More information

Turbine Flow Sensor Series VTR

Turbine Flow Sensor Series VTR Turbine Flow Sensor Series VTR SIKA Turbine Flow Sensor Series VTR Extra robust, impressively precise SIKA s VTR turbine flow sensor allows you to determine precisely, dependably and easily the flow rates

More information

400 Series Buccaneer BUCCANEER POWER. bulgin

400 Series Buccaneer BUCCANEER POWER. bulgin bulgin BUCCANEER FOR POWER Contact Retainer Sealing Gasket O Ring Contacts Locking Ring Retaining Nut Panel Body Contacts Contact Carrier O Ring Main Body Cable Gland Collet Gland Nut Sealed to IP68 when

More information

Electric Rotary Actuator - On/Off or programmable control actuator

Electric Rotary Actuator - On/Off or programmable control actuator Electric Rotary Actuator - On/Off or programmable control actuator Direct mounting on quarter-turn valves Manual override standard Corrosion resistant Adjustable limit switches Multi-voltage version Type

More information

FRL/AirCare Air Controls & Accessories

FRL/AirCare Air Controls & Accessories FRL/irare ir ontrols & ccessories Lincoln Regulators, Filters & Lubricators well-planned compressed air system ensures minimum pressure loss in the system, and the removal of contaminants: water, compressor

More information

EVC40 EMERGENCY VOICE COMMUNICATION SYSTEM

EVC40 EMERGENCY VOICE COMMUNICATION SYSTEM EVC40 EMERGENCY VOICE COMMUNICATION SYSTEM INSTALLATION MANUAL Protec Fire Detection PLC, Protec House, Churchill Way, Nelson, Lancashire, BB9 6RT. Telephone: +44 (0) 1282 717171 Fax: +44 (0) 1282 717273

More information

SOURIAU s discrete wire sealing

SOURIAU s discrete wire sealing SOURIAU s discrete wire sealing Description Using proven grommet technology from SOURIAU s extensive knowledge of harsh environments, the UTO & UTS connectors with grommet garantie a discrete wire sealing

More information

COAXICON Contacts. RF Coax Connectors. Product Facts

COAXICON Contacts. RF Coax Connectors. Product Facts COXICON Contacts Product Facts Tyco Electronics provides a variety of contacts for coaxial connectors Contacts are available in a range of sizes that may be used with the various types of coaxial cable

More information

Batibox TM flush-mounting boxes for dry partitions

Batibox TM flush-mounting boxes for dry partitions flush-mounting boxes for dry partitions 800 51 800 42 800 53 800 54 800 42 + 800 71 800 77 Cat.Nos 1-gang boxes For 1 module 20 800 40 Drilling diameter 32 mm Depth 40 mm For 1 gang or 2 modules For wiring

More information

Transformers from 25va to 500kva. Standard despatch in days not weeks

Transformers from 25va to 500kva. Standard despatch in days not weeks Transformers from 25va to 500kva Standard despatch in days not weeks JMS Transformers Ltd 20 Ivatt Way Westwood Business Park Peterborough PE3 7PG UK Tel: +44 (0)1733 760000 Fax +44 (0)1733 760004 e-mail:

More information

3/2-way Mini Solenoid Valve

3/2-way Mini Solenoid Valve 3/2way Mini Solenoid Valve Directacting 0... bar DN mm... DN mm,,, subbase, banjobolt connection 21mm coil spacing when mounted on manifold Type can be combined with... Type 20 Type 207 Type able plug

More information

Aluminium Standard. Technical Data. Included in delivery

Aluminium Standard. Technical Data. Included in delivery luminium Standard UL / cul Robust aluminium enclosure for mechanical engineering and automation technology Fixing options for s and mounting plates Usable in wide temperature area Technical ata aterial:

More information

Linear modules Lifting units Rotary modules Grip modules Inductive proximity switches Plug connectors

Linear modules Lifting units Rotary modules Grip modules Inductive proximity switches Plug connectors 20000 Linear modules Lifting units Rotary modules Grip modules Inductive proximity switches Plug connectors 23000 22000 21000 20000 09000 08000 07000 06000 05000 04000 03000 02000 01000 823 Notes 824 Technical

More information

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2... Magnetic and Hydraulic-Magnetic Circuit Breaker 840-G2... Description Single, two and three pole magnetic circuit breakers with trip-free mechanism and push/pull on/off manual actuation. A choice of fast

More information

Linear Luminaire with LED Series EXLUX 6402/2

Linear Luminaire with LED Series EXLUX 6402/2 > Latest LED technology with a high luminous efficacy and a long service life > As pendant light fitting or side entry lamp > Central locking > All-pole disconnection by means of an N/C switch when the

More information

3/2-way Solenoid Valve, direct-acting, NC or NO

3/2-way Solenoid Valve, direct-acting, NC or NO 3/2-way Solenoid Valve, direct-acting, NC or NO Electrical connection cable plug, Form A With or without manual override as standard Threaded port and sub-base s Impulse optional Type 6014 can be combined

More information

Figure 1 (end) Updated document to corporate requirements Added text to Paragraph 2.4

Figure 1 (end) Updated document to corporate requirements Added text to Paragraph 2.4 This specification covers the requirements for application of ELCON Drawer Series Connectors: True Hot Plug, Blind Mating Mixed Signal and Power Connectors. These connectors are designed for use in pluggable

More information

6000 Series Buccaneer. 30 twist locking Tamperproof lock prevents accidental un-mating. Cat 5e shielded coupler Maintains shielding

6000 Series Buccaneer. 30 twist locking Tamperproof lock prevents accidental un-mating. Cat 5e shielded coupler Maintains shielding circular connectors that combine the ease of use of a push/pull coupling mechanism with proven environmental sealing. Available with metal or plastic bodies, the range supports both data (USB and Ethernet),

More information

Glenair Military and Industrial Power and Signal Connectors

Glenair Military and Industrial Power and Signal Connectors Glenair Military and Industrial Power and Signal Connectors Series ITS (And FRITS) 5015 Type Reverse Bayonet Connectors Derived from MIL-DTL-5015 and VG95234 Mating mechanism (3 reverse bayonets at 120

More information

8146 Series Terminal Boxes

8146 Series Terminal Boxes Series Terminal oxes TERMINTION Ready-Term Terminal oxes Features: Pre-onfigured with terminals mounted Made of Fiberglass Reinforced Polyester (FRP) enclosure sizes with different depths For power and

More information

Electro-hydraulic pressure switches type DG

Electro-hydraulic pressure switches type DG Electro-hydraulic pressure switches type DG Pressure p max = 700 bar See also: For electronic pressure switches type DG 5 E see D 5440 E Analogous pressure transducer type DT 1 see D 5440 T Analogous pressure

More information

01. HARTING RJ INDUSTRIAL RJ45 ETHERNET CONNECTORS

01. HARTING RJ INDUSTRIAL RJ45 ETHERNET CONNECTORS . HARTING RJ INDUSTRIAL ETHERNET CONNECTORS Ethernet is is coming up to standard industrial interface. Therefore, automation devices such as controllers, sensors and actuators feature possess on one or

More information

Cable Plug acc. to DIN EN 175301-803, Form A

Cable Plug acc. to DIN EN 175301-803, Form A Cable Plug acc. to DIN EN 175301-803, Form A Complete program Contact form 18 mm Also available with LED indicator Optional 4-pin version for pressure switch or impulse valves respectively Versions with

More information

PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES

PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES BUSHING WITH PLUG CONNECTION WITH OUTER CONE PPS CHARACTERISTICS The PPS bushing can be used as a fixed section for the entry of medium

More information

8146/5 Series Breaker Panelboards

8146/5 Series Breaker Panelboards 8146/5 Series Breaker Panelboards DISTRIBUTION BREAKER PANELBOARDS FOR HAZARDOUS & CORROSIVE ENVIRONMENTS Breaker Panels Features: Wide variety of Flameproof branch circuit breakers for Zone 1 & Division

More information

LIEBERT VNSA Installation Sheet

LIEBERT VNSA Installation Sheet LIEBERT VNSA Installation Sheet Description The Liebert vnsa network switch is designed for connecting multiple Ethernet-ready devices and comes in various models. The unit may have: A Liebert icom display

More information

DiwiTherm, Resistance Thermometers Model TR75, with digital Display Battery or Solar Powered

DiwiTherm, Resistance Thermometers Model TR75, with digital Display Battery or Solar Powered Electrical Temperature Measurement DiwiTherm, Resistance Thermometers Model TR75, with digital Display Battery or Solar Powered WIKA Data Sheet TE 60.75 Applications Machinery, plant and tank construction

More information

Assisted lift operated 2/2-way solenoid valves Type EV250B

Assisted lift operated 2/2-way solenoid valves Type EV250B MAKING MODERN LIVING POSSIBLE Data sheet Assisted lift operated 2/2-way solenoid valves Type EV250B EV250B with assisted lift can operate from zero and up to 10 bar differential pressure. This 2/2-way

More information

Sarasota Splash Back Prep and Shine Paint Restorer Inside Front Cover

Sarasota Splash Back Prep and Shine Paint Restorer Inside Front Cover Caution: Read entire label before using product. Do-It-Yourself PAINT RESTORER KIT Kit Contains: 1-16 oz. Water-based, Biodegradeable Liquid Prep 1-16 oz. Aerosol Shine Spray 1 - Spray Nozzle 2 - Scrub

More information

Rack installation instructions

Rack installation instructions Rack installation instructions Review the documentation that comes with the rack cabinet for safety and cabling information. Before you install the server in a rack cabinet, review the following guidelines:

More information

Trade of Electrician. Three-phase Distribution Boards And Socket Circuits

Trade of Electrician. Three-phase Distribution Boards And Socket Circuits Trade of Electrician Standards Based Apprenticeship Three-phase Distribution Boards And Socket Circuits Phase 2 Module No. 2.3 Unit No. 2.3.2 COURSE NOTES Created by Charlie Walsh - Athlone TC Revision

More information

Linkeo 19" freestanding cabinets

Linkeo 19 freestanding cabinets 87045 LIMOGES Cedex France Telephone: (+33) 05 55 06 87 87 - Fax: (+33) 05 55 06 88 88 Linkeo 19" freestanding cabinets Page 1. General characteristics....1 2. Range....2 3. Technical characteristics...3

More information

Terminal Boxes Series 8146

Terminal Boxes Series 8146 Series > Enclosures in shock-resistant glass fibre reinforced polyester resin > basic enclosure sizes various heights > Fitted according to the customer's requirements > For terminals up to max. 00 mm

More information

Electrically operated valves Series M-05, 3/2-, 5/2- and 5/3-way G1/8 650 and 750 Nl/min (0.661 and 0.762 Cv)

Electrically operated valves Series M-05, 3/2-, 5/2- and 5/3-way G1/8 650 and 750 Nl/min (0.661 and 0.762 Cv) Electrically operated valves Series M-05, 3/2-, 5/2- and 5/3-way G1/8 650 and 750 Nl/min (0.661 and 0.762 Cv) Order code Series and function M-05-310-HN-442 Standard coil HN at ports 2 + 4 HN at ports

More information

3-Component Measuring System

3-Component Measuring System Force 3-omponent Measuring System for utting Force Measurement During Turning Modular system for measurement of cutting forces when turning outside and inside diameters on turret lathes. Machine adapters

More information

Plugs, Sockets and Switches

Plugs, Sockets and Switches Plugs, Sockets and Switches Solutions for all domestic, commercial and industrial installations PLUGS, SOCKETS & SWITCHES NHP Electrical Engineering Products Pty Ltd Sales 1300 NHP NHP nhp.com.au Contents

More information

FILTRATION AMIAD PLASTIC FILTERS, SCREENS & DISCS

FILTRATION AMIAD PLASTIC FILTERS, SCREENS & DISCS 4 AMIAD PLASTIC FILTERS, SCREENS & DISCS Max pressure 10.0 Bar, max temperature 60 O 3/4 to 1 1/2 bodies manufactured from polyacetal 2 bodies and above manufactured from polymade and glass fibre 3/4 to

More information

A good connection. International approvals.

A good connection. International approvals. E X - P L U G S A N D R E C E P T A C L E S A to A Plastic version for Zone and Zone A good connection Providing electrical energy there, where it is most needed even in hazardous areas for the Zones,,

More information

Reaction Torque Sensor

Reaction Torque Sensor Force 1 1 N m up to 1 000 1 000 N m Type 9329A 9389A These easy to install piezoelectric reaction torque sensors are particularly suitable for measuring rapidly changing torques at non-rotating shafts.

More information

Parts Manual. TWIN 2 & 3 Parts & Accessories F210846R01. Your efficiency is our Challenge!

Parts Manual. TWIN 2 & 3 Parts & Accessories F210846R01. Your efficiency is our Challenge! Parts Manual TWIN 2 & 3 Parts & Accessories F210846R01 Your efficiency is our Challenge! All rights reserved. No part of this manual may be copied and/or published by means of printing, photocopying, microfilm

More information

CLIX POWER SYSTEMS PLUG-AND-PLAY SYSTEM FOR SHORE POWER INSTALLATIONS MARINE AND MOBILE APPLICATIONS

CLIX POWER SYSTEMS PLUG-AND-PLAY SYSTEM FOR SHORE POWER INSTALLATIONS MARINE AND MOBILE APPLICATIONS CLIX POWER SYSTEMS PLUG-AND-PLAY SYSTEM FOR SHORE POWER INSTALLATIONS MARINE AND MOBILE APPLICATIONS Are you planning to install a shore power system on your boat, but you are not sure if you are: a) allowed

More information

POSEIDON 2-29, 2-25 & 2-22 POSEIDON 2-29, 2-25 & 2-22 XT

POSEIDON 2-29, 2-25 & 2-22 POSEIDON 2-29, 2-25 & 2-22 XT POSEION 2-29, 2-25 & 2-22 POSEION 2-29, 2-25 & 2-22 XT Repair Manual Index A. Safety precautions 3 B. Technical data 4 C. Structure 5-6. Service / Repair 7-23 E. Tools 24 F. Function 25-26 G. Electric

More information

PRESSURE REDUCING VALVES

PRESSURE REDUCING VALVES 0E0-GB PRESSURE REDUCING VAVES MAIN FEATURES The pressure reducing valve is able, by varying its pressure drops, to hold the downstream pressure of the fluid at a constant level against changes in the

More information

VOT-320. VOT-320V0xxL VOT-320V0xxH. Quick Installation Guide

VOT-320. VOT-320V0xxL VOT-320V0xxH. Quick Installation Guide VOT-320 VOT-320V0xxL VOT-320V0xxH en Quick Installation Guide VOT-320 Table of Contents en 3 Table of Contents 1 General information 4 2 Parts included 5 3 Unpacking 6 4 Installing and connecting 7 4.1

More information

Safety & Environmental Protection Services Guidance Note

Safety & Environmental Protection Services Guidance Note Safety & Environmental Protection Services Guidance Note A STEP-BY-STEP GUIDE TO VISUAL INSPECTION OF ELECTRICAL EQUIPMENT Why Inspect? The Health and Safety at Work etc Act 1974 and the Electricity at

More information

T A B L E T 1 T E S T S A N D I N S P E C T I O N C A B L E P C U T A N D P C U T - A

T A B L E T 1 T E S T S A N D I N S P E C T I O N C A B L E P C U T A N D P C U T - A T A B L E T 1 1 of 7 Tests & Inspection Cable PCUT & PCUT-A (Table T1) T E S T S A N D I N S P E C T I O N C A B L E P C U T A N D P C U T - A No. Test Scale MOC Requirements G 20:10:001:01 Defined Test

More information

SMA Interface Mating Dimensions (Per MIL-STD-348)

SMA Interface Mating Dimensions (Per MIL-STD-348) SMA Series SMA 6 SMA Interface Mating Dimensions (Per MIL-STD-348) SMA Interface Dimensions MALE Inches/Millimeters 3 Minimum Nominal Maximum LTR in. mm in. mm in. mm A.250 6.35.263 6.68.. B.1790 4.55.1808

More information

Amphenol C 091 A/B/D. Circular Connectors. Amphenol-Tuchel Electronics GmbH

Amphenol C 091 A/B/D. Circular Connectors. Amphenol-Tuchel Electronics GmbH Amphenol C 091 A/B/D Circular Connectors Amphenol-Tuchel Electronics GmbH C 091 A Main Features Metal threaded coupling acc. to IEC. Number of contacts are 2 to 8, 12 and 14. Internal metal strain relief

More information

Givare NC-SRS 280 och 880

Givare NC-SRS 280 och 880 Givare NC-SRS 280 och 880 Aratron AB/Nordic Control, 02 03 SRS280SEALED ROTARY SENSOR PERFORMANCE ±2 Resistance ±20% Hysteresis (repeatability) Accuracy Applied voltage maximum Resolution Output smoothness

More information

20000068 WIRELESS REMOTE ASSEMBLY, 24VDC, 1 TRANS,1 REC

20000068 WIRELESS REMOTE ASSEMBLY, 24VDC, 1 TRANS,1 REC 20000068 WIRELESS REMOTE ASSEMBLY, 24VDC, 1 TRANS,1 REC Fitment to MP-25 620 CR 4841, Haslet, TX 76052 Ph 817.439.1108 Fax 817.636.5675 www.machine-technologies.com Kit contents 1 Transmitter 2 button,

More information

CMD Series. 4 Contact Row High Density Signal Connectors. Technical Characteristics

CMD Series. 4 Contact Row High Density Signal Connectors. Technical Characteristics MD Series 4 ontact Row High Density Signal onnectors Offset-grid layout, four rows within dielectric connector body, mm center-to-center spacing in each row and row-to-row spacing. 0.6 mm nominal pin DI

More information

Directory chapter 02 - DIN Power (to 6 A) Types D, E, F, FM, 2F, F9, interface connectors I/U 02. 01. Technical characteristics types D and E... 02.

Directory chapter 02 - DIN Power (to 6 A) Types D, E, F, FM, 2F, F9, interface connectors I/U 02. 01. Technical characteristics types D and E... 02. Directory chapter 02 - () Types D, E, F, FM, 2F, F9, interface connectors I/U Page Technical characteristics types D and E.............................. 02.10 Type D connectors.................... 02.11

More information

SLAM-SHUT VALVE. Type OSE. Europe, Middle East, Africa and Asia Pacific Documents Only. Process Management TM

SLAM-SHUT VALVE. Type OSE. Europe, Middle East, Africa and Asia Pacific Documents Only. Process Management TM SLAM-SHUT VALVE Type OSE Process Management TM DESCRIPTION The purpose of the OSE slam shut valve is to totally and rapidly cut off gas flow when the outlet pressure exceeds or drops below the setting.

More information

RUBBER SLEEVE KNIFE GATE VALVE

RUBBER SLEEVE KNIFE GATE VALVE RUBBER SLEEVE KNIFE GATE VALVE The model knife gate is a wafer valve designed for a wide range of industrial applications. The double-seated design provides bi-directional shut off. The design of the valve

More information

TOYOTA Tundra 2007 - BACK-UP CAMERA SYSTEM Preparation

TOYOTA Tundra 2007 - BACK-UP CAMERA SYSTEM Preparation Preparation Part Number(s): PT233-34070, PT923-35070-11, PT923-35070-43 NOTE: Part number of this accessory may not be the same as part number shown. Back Up Monitor Kit Contents PT923-35070-11 / PT923-35070-43

More information

ABB. Installation Enclosures Meter Boxes. SMB s. DMB s. Enclosures

ABB. Installation Enclosures Meter Boxes. SMB s. DMB s. Enclosures Meter Boxes SMB s To house a single phase kilowatt hour meter Standard kwh meter mounting Square or triangular securing screw Stand off for circuit breaker Optional circuit breaker reset rod DMB s To house

More information

Ammeraal Beltech Modular

Ammeraal Beltech Modular mmeraal eltech Modular Innovative belt and chain solutions for every industry & application www.unichains.com Content uni MP C page 3-6 uni MP 16% page 7-10 uni MP 18% page 11-14 uni MP 20% page 15-18

More information

Accessories for Enabling Switches

Accessories for Enabling Switches BD Male plug SS Female connector C- Male flange connector SD Female connector BS Extension cable BD -pin + PE Dimension drawings Male plug SS -pin + PE Female connector C- -pin + PE BD for male plug SS

More information

HARTING Ethernet Cabling 4-poles Overview

HARTING Ethernet Cabling 4-poles Overview Overview RJ45 Connectors [on page 8] System cables [on page 10] Distribution modules and Outlets [on page 20] HARTING PushPull Connectors [on page 22] System cables [on page 24] Panel feed-throughs [on

More information

Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5

Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5 Model Number Single head system Features Parameterization interface for the application-specific adjustment of the sensor setting via the service program ULTRA 000 programmable switch outputs Hysteresis

More information

I N D U S T R I A L C A B L E G L A N D S

I N D U S T R I A L C A B L E G L A N D S Introduction 1/2 Industrial Cable Gland W Industrial Cable Gland WL Heavy Duty Industrial Cable Gland CW Industrial Cable Gland CZ Industrial Cable Gland 1W Industrial Cable Gland 1Z Industrial Cable Gland

More information

Outdoor Use Waterproof I/O Connectors (Optical / Modular / Electrical) FO-BH, FO-BC, NT5, JN2 / W Series

Outdoor Use Waterproof I/O Connectors (Optical / Modular / Electrical) FO-BH, FO-BC, NT5, JN2 / W Series COMPONENTS PRODUCT INFORMATION RoHS Compliant NEW Outdoor Use Waterproof I/O Connectors (Optical / Modular / Electrical) FO-BH, FO-BC, NT5, JN2 / W Series Optical FO-BH Series (Compact Type) CONNECTOR

More information

Safety detection solutions

Safety detection solutions Presentation, actuator operated etal, types CS A, CS B, CS C and CS E Plastic, double insulated, turret head, types CS P or CS PA or CS TA and CS TE etal, types CS A, CS B, CS C, CS E with or without locking

More information

TBi Industries. MIG / MAG Welding torches TBi Expert 0. 1

TBi Industries. MIG / MAG Welding torches TBi Expert 0. 1 TBi Industries MIG / MAG Welding torches TBi Expert 1 0. 1 CONTENTS. TBi Expert Gas cooled torches TBi 150 Classic Series 60% (10 min.) Mix : 150 A CO 2 : 180 A Ø 0.6-1.0 mm Water cooled torches TBi 240

More information

Laserlyte-Flex Alignment System

Laserlyte-Flex Alignment System Laserlyte-Flex Alignment System LaserLyte-Flex The LaserLyte-Flex Alignment System is a unique, interchangeable, low cost plug and play laser system. Designed specifically for aligning and positioning

More information

RJF TV Ethernet connection system for harsh environment

RJF TV Ethernet connection system for harsh environment RJF TV Ethernet connection system for harsh environment ROHS compliant N & BZ RJFTV allows you to use an Ethernet Class D / Cat. 5e connection for 10 BaseT, 100 BaseTx or 1000 BaseT networks in harsh environments.

More information

British Standard Underground Hydrant Range

British Standard Underground Hydrant Range British Standard Underground Hydrant Range 2 THE NEW AVK BRITISH STANDARD HYDRANT RANGE AVK are the renowned market leading innovators, manufacturers and suppliers of BS 750 fire hydrants into the UK,

More information

AMP Standard Terminals and Splices. RoHS. Ready

AMP Standard Terminals and Splices. RoHS. Ready AMP Standard Terminals and Splices RoHS Ready Table of Contents Product Facts Solderless terminals and splices performs up to today s standards for reliable termination in applications ranging from control

More information

Lift-off hinge. Rising hinge. Standard hinge. Heavy duty hinge. Parliament hinge. Spring hinge. Double action spring hinge. Concealed mortise hinge...

Lift-off hinge. Rising hinge. Standard hinge. Heavy duty hinge. Parliament hinge. Spring hinge. Double action spring hinge. Concealed mortise hinge... Door Hinges Contents Butt hinges Lift-off hinge Rising hinge Standard hinge Heavy duty hinge Parliament hinge Spring hinge Double action spring hinge Concealed hinges Concealed mortise hinge... Pivot

More information

picomax The Pluggable Connection System

picomax The Pluggable Connection System picomax The Pluggable Connection System TECHNOLOGY THIS SPECIALIZED CAN T MEET ALL REQUIREMENTS. YES IT CAN. CONTENTS picomax Pin spacing: 3. mm/0.138 in;.0 mm/0.197 in; 7. mm/0.29 in Versatile Pluggable

More information

Operators manual Basic water heater

Operators manual Basic water heater Operators manual Basic water heater Isotemp Basic water heater has been designed and produced to ensure that your water heater will give long and trouble free operation for many years. It is important,

More information

New. absolute filter elements independently tested in the following Institutes: MPH-MPI 02050/7.99/USA 2 COVER INSERT

New. absolute filter elements independently tested in the following Institutes: MPH-MPI 02050/7.99/USA 2 COVER INSERT e s c r i p t i o n MPH and MPI series filters are designed for returnline applications and provide various installation applications. The filters are installed semiimmersed or totally immersed into a

More information

ANOISON HPQN SERIES HPQN CONNECTORS INTERFACE DIMENSIONS. Description. Interface Dimensions 21 Characteristics

ANOISON HPQN SERIES HPQN CONNECTORS INTERFACE DIMENSIONS. Description. Interface Dimensions 21 Characteristics SERIES HPQN CONNECTORS DESCRIPTION CONTENT Designed by James Qu at Anoison in 2006, the HPQN is a quick locking version of the widely used type N connector. By replacing the threaded interface of the original

More information

Valu Guide Sheaths. Valu Guide Inserts. Optional Valu Guide Inserts. Typical Properties of Valu Guide Rail. and Hardware.

Valu Guide Sheaths. Valu Guide Inserts. Optional Valu Guide Inserts. Typical Properties of Valu Guide Rail. and Hardware. 14 gauge stainless steel The Original, Long Life Sanitary Guide Rail Valu Guide rail incorporates two outstanding materials: stainless steel and UHMW. The 14 ga. stainless steel sheath provides rigid streamlined

More information

Type 3353 Angle Seat Valve

Type 3353 Angle Seat Valve Type 3353 Angle Seat Valve Application On/off valve with pneumatic piston actuator Nominal size DN 15 to 50 (NPS ½ to 2) Nominal pressure PN Temperature range 10 to 180 C Globe valve with an angle seat

More information

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 55 Series - General purpose relays 7-10 A Features 55.12 55.13 55.14 Printed circuit mount, general purpose 2, 3 & 4 Pole relays 55.12-2 Pole 10 A 55.13-3 Pole 10 A 55.14-4 Pole 7 A AC coils & DC coils

More information