PW Cable Tray Ladder, Trough & Solid Bottom

Save this PDF as:
 WORD  PNG  TXT  JPG

Size: px
Start display at page:

Download "PW Cable Tray Ladder, Trough & Solid Bottom"

Transcription

1 PW Cable ray adder, rough & Solid Bottom Metallic Covers & Cover Connectors Covers protect and contain cables. hey are highly recommended to avoid damage to the tray contents and to protect against the elements. Covers can also be attached to the tray with hinges; please contact egrand/cablofil for more information. SOID COVERS flat, non-flanged OUVERED COVERS flat, non-flanged material flange in 1" flange out 1 3 /4" flange out [ ] ] [ ] [ cover System solid, flat non-flanged A M flat, flanged* peaked 15, flanged flat, flanged* * Flange is 3/8" wide. 15 is standard angle for peaked covers. Flange is 3/8" wide. solid, flat flanged A M G solid, peaked 15 flanged A M G louvered, Flat non-flanged A M SQUARE CORNER cover Catalog ing example: Square-corner fittings require special covers with a unique ing system. See page 22 for square corner fitting. Cover System No. Fitting Product No louvered, Flat flanged A M G W W W Width (W) Fitting angent () Widths (W) in Rail Heights (H) in 26 cover Catalog ing example: Cover System No. Side Rail Height* 40 4" 50 5" 60 6" 70 7" * Side rail height necessary for outside vertical fitting covers. ** Standard lengh for steel covers hot-dip galvanized after fabrication per ASMA-123 is 6'-0". ength or Fitting Product No J ength 0006** 6' ' ' or 9224 Fitting Product No. his identifies fitting type and radius Width Fitting angent 02 2" angents (Series 1) 05 5" angents (Series 2) Cover hickness etter suffixes are used to indicate alternate cover thicknesses. eave blank for standard thickness. A Standard: 0.040" H 0.063" J 0.080" 0.125" Diamond readplate: S 0.125" Standards: G 18 Ga. M 20 Ga. A 18 Gage (0.048") B 16 Gage (0.060") C 14 Gage (0.075")

2 flat cover connectors A M G * For use with indoor, outdoor, or vertical flat covers. op and bottom pieces are 1 1 /2" wide. Install one connector over each cover joint and space additional connectors on 36"- 48" centers. channel-style strap-style 1400 ZN s included Zinc-plated Steel 316 Stainless Steel 1423 CD s included Cadmium-plated Steel 316 Stainless Steel peaked cover connectors A M G * For use with indoor, outdoor, or vertical peaked covers. op and bottom pieces are 1 1 /2" wide. Install one connector over each cover joint and space additional connectors on 36"- 48" centers. Standard angle of peaked cover is 15, but custom angles are possible. Please contact egrand/cablofil for more information. Channel-style strap-style s included s included 1411 ZN Zinc-plated Steel 316 Stainless Steel 1440 CD Cadmium-plated Steel 316 Stainless Steel cover connector Catalog ing example: Fitting System No. Product No. 6a2O s6 Side Rail Height A M G* *optional Fitting Series Flange Direction Width ZN CD A Aluminum M Steel, Mill Galvanized ZN Zinc-plated Steel G Steel, Hot-dip Galvanized CD Cadmium-plated Steel ype 304 Stainless Steel ype 316 Stainless Steel ype 316 Stainless Steel 27

3 PW Cable ray adder, rough & Solid Bottom Metallic Cover Accessories cover connector clips h-binder cover joint strip A For use with indoor, horizontal covers. Flange-in clip requires tray with 1" side rail flanges. Flange-out clip works with any side rail flange width. Sold individually. H-Binder Strip Closes gaps at cover joints. Notched for the tray side rail. No s required. Flange-in clip Flange-OU clip H-Binder Strip Abutting Covers Abutting Covers description no. Flange-in 1410 Flange-out 1853 catalog ing example (ea.): included No. Strip 0925 All flat covers peaked covers Connector System No. Width A2o AI, A1O and A2O are the only three Connector System No. possiblities for this part. raised cover connector A M G * For use with all covers, indoors and outdoors. Covers are attached to uprightmounted C channel on the top of the cable tray. Install 36" - 48" on center. Flat or Peaked Cover with Flanges Gap Series 1 Fitting side rails have 2" tangents (flat portion beyond curvature) at the end of each fitting, to accommodate splice plates. gap dimension Series 2 no. 1" " " " 1444 ZN Fitting System No. Width 6A2o Fitting side rails have 5" tangents at the end of each fitting, to accommodate splice plates. A Aluminum M Steel, Mill Galvanized ZN Zinc-plated Steel G Steel, Hot-dip Galvanized CD Cadmium-plated Steel ype 304 Stainless Steel ype 316 Stainless Steel ype 316 Stainless Steel 28

4 splice plates A G Cadmium-plated steel s are standard for all splice plate connectors on aluminum and steel cable tray systems. All splices are supplied in pairs. ype 316 stainless steel s are standard on stainless steel systems, but are available as an option on all aluminum and steel systems. Sufficient connector pairs with s are automatically included with each shipment of straight sections and fittings. Extras for field cuts or spares must be ordered separately. Bonding jumpers are required for all expansion splice plates, adjustable connectors, and tray discontinuities. he symbol indicates that bonding jumpers are required. Standard splice mid-span splice 1 2 hese heavy-duty splice plates are designed for random location, including mid-span. Field-drilled holes are required in the bottom flanges of adjoining trays. Sold in pairs. Sold in pairs. 02 CD Connector System No. 4A1-02 -CD Mid-span splice plates are designed for use with Series 2 tray systems only. 85 CD Connector System No. 4A his item must be specified as Series 2 in the System No. universal splice hese splice plates are designed to connect to existing cable tray. Sold in pairs. 1 2 reducing height splice hese splice plates are designed to connect cable tray side rails with different heights. he connector system includes the larger side rail height. Choose the depending on the side rail height you are reducing to. Sold in pairs CD Connector System No. 4A1-35 -CD size 86 Reduces to 4" high tray 79 Reduces to 5" high tray 55 Reduces to 6" high tray CD Rail Heights (H) in Connector System No. 6A2-86 -CD 29

5 PW Cable ray adder, rough & Solid Bottom Metallic Splices & Connectors splices and connectors A G Cadmium-plated steel s are standard for all splice plate connectors on aluminum and steel cable tray systems. All splices are supplied in pairs. ype 316 stainless steel s are standard on stainless steel systems, but are available as an option on all aluminum and steel systems. Sufficient connector pairs with s are automatically included with each shipment of straight sections and fittings. Extras for field cuts or spares must be ordered separately. Bonding jumpers are required for all expansion splice plates, adjustable connectors, and tray discontinuities. he symbol indicates that bonding jumpers are required. Permits thermal contraction and expansion in a cable tray installation. he length of the straight cable tray run and the temperature differential govern the and spacing of expansion connectors. Expansion splice plates permit 2" of movement. Sold in pairs. expansion splice RN 2 straight reducer splice Designed to fit Series 1 & 2 systems. 14 CD Connector System No. 4A2-14 -CD his item must be specified as Series 2 in the System No. Designed to fit Series 1 & 2 systems. 03 CD Connector System No. RN 4A CD his item must be specified as Series 2 in the System No. offset reducer splice 90 connector RN A RAY WIDHS 04 CD Connector System No. RN 4A his item must be specified as Series 2 in the System No. 20 CD Connector System No. 4A2-20 -CD his item must be specified as Series 2 in the System No. Widths (W) in Rail Heights (H) in Reduction (RN) in 30

6 splices and connectors A G All splices are supplied in pairs. Bonding jumpers are required for use with all adjustable splices. floor flange/tray-to-box connector horizontal adjustable splice plate for tray attachment only are included. Floor connection leg has 9/16 diameter hole. For odd angle bends up to 30 A W Designed to fit Series 2 systems only CD catalog ing example (pair): Connector System No.* 4G CD *his item must be specified as Series 2 in the System No. 7/16 DIA HOES Designed to fit Series 1 & 2 systems. W 05 CD Connector System No.* 4A2-05 -CD *his item must be specified as Series 2 in the System No. verical adjustable splice plate vertical hanger splice plate tray-to-box connector, frame-type B A W A W 7/16 DIA HOES Designed to fit Series 1 & 2 systems. Maximum bend angle is CD Connector System No.* 4A2-07 -CD *his item must be specified as Series 2 in the System No. Designed to fit Series 1 & 2 systems CD Connector System No.* 6G *his item must be specified as Series 2 in the System No. Designed to fit Series 2 systems only. B 0403 CD Dimensions A H /4 B W + 4 catalog ing example (EA.): Connector System No. Width 4A CD A 31

7 PW Cable ray adder, rough & Solid Bottom Metallic Bonding Jumpers bonding jumpers Use across all discontinuities, expansion joints, and adjustable connectors to maintain electrical continuity in the cable tray system. Also use to bond the cable tray system to the building ground. Bonding jumpers are not required at standard or rigid splice locations. for bonding jumpers must be ordered separately. laminated aluminum insulated copper aminated aluminum RAED AMPS (N.E.C ) " or 22" 2000 catalog ing example (EA:): ength A A aminated Aluminum: Use (4) 3 /8" x 1" bolts per Bonding Jumper. Insulated Copper: Made with flame-retardant, moisture- and heat-resistant, insulated copper cable. in plated copper lugs have one hole, sized for 3 /8" x 3 /4" bolt. ength is 15" to the center of the lug holes. Special lengths, lugs, and cables are also available. 15" insulated copper Copper Cable Size RAED AMPS (N.E.C ) A806 #6 200 A807 #4 300 A804 #2 500 A803 #1 600 A808 1/O 800 A809 2/O 1000 A805 3/O 1200 A810 4/O 1600 A814* 4/O Welding Cable 2107 Strands 1800 catalog ing example (ea.): C - A806 * ength is 30" to the center of the lug holes. One-hole tin-plated copper lugs are sized for 1 /2" bolt. C s for splices description Knurled Bolt Flanged Hex Nut ocking Hex Nut Flat Washer SIZE 3/8"-16 x 3 /4" 3/8" Dia. 3/8" Dia. 3/8" Dia. Complete Catalog DS CD CD DS DS CD CD DS DS CD CD DS DS CD CD DS Knurled Bolt: Specially designed for cable tray connectors, the ribbed neck firmly grips the tray side rail to prevent screw rotation while tightening. Bolt can also be tightened with a Phillips screwdriver. Flanged Hex Nut: Free spinning lock-type nut with a serrated face, eliminating the need for a washer. Nuts require a 9 /16" wrench. ighten to approx ft-lbs of torque. ocking Hex Nut: For use with expansion connectors. Deformed threads cause this nut to lock on to the bolt after just a few turns, allowing movement of the bolt in the expansion slot without possibility of the nut backing off. ypically identified by a rectangular indentation on the side of the nut. Flat Washer: For use with expansion connectors. Install under the locking hex nut in the expansion slots. Prevents binding in the expansion slot during movement of the tray due to thermal expansion. A Aluminum C Copper M Steel, Mill Galvanized ZN Zinc-plated Steel G Steel, Hot-dip Galvanized CD Cadmium-plated Steel ype 304 Stainless Steel ype 316 Stainless Steel ype 316 Stainless Steel Rail Heights (H) in 32

8 Divider Strips divider strips A M G * Straight strips are for use with all straight tray; flexible strips are for use with all horizontal fittings of any radius. Straight Horizontal Divider Furnished with four #10 self-drilling screws. vertical fitting Divider ' ZN Accessory System No. 4A ZN Flexible Horizontal Divider Furnished with three #10 self-drilling screws ' ZN Accessory System No R Divider type Accessory System No. 90 Inside Elbow 90 Outside Elbow 60 Inside Elbow 60 Outside Elbow 45 Inside Elbow 45 Outside Elbow 30 Inside Elbow 30 Outside Elbow ZN 4a ZN Furnished with two #10 self-drilling screws. 33

9 PW Cable ray adder, rough & Solid Bottom Metallic Divider Accessories divider hold down clip A M G * Purchased separately. Supplied with carriage bolt and flanged hex nut. Designed for use with ladders with box-shaped rungs (ypes A, AH, BX & BH see page 47). 5" Vinyl divider splice Splices joints of abutting divider strips. Vinyl edge strip is also available in bulk lengths. V 5" No. No ZN 0930 Divider splice A ZN self-drilling screw catalog no. example: V Sold in bags of 25. Provided with all dividers, but extras can be ordered separately. A M complet Cat. No. COJ-A COJ-PG COJ-316 Complete catalog No. size DS ZN ZN #10 x 3 /4" DS #10 x 3 /4" 34

10 Accessories blind end plate A M G * cable dropout A M G * Seals off the open end of a cable tray. Attaches to the tray using standard 3 /8" dia. connector s. Provides a smooth, rounded surface for cables dropping out of the bottom of the cable tray CD Accessory System No. Width No. R / ZN -Flange Width AI ray width (nominal) Dropout width (Flg In) 2 1 /4 5 1 /4 8 1 / / / / /4 Dropout width (Flg Out) 5 1 /4 8 1 / / / / / /4 in wall penetration sleeve M G Outdoor conversion for wall penetration G Provides a rigid support for cable tray at wall penetrations. Overall length of the sleeve is 20". Will fit walls up to 8" thick. Bonding jumpers are not required for use with wall sleeves. wo pairs of splice plates and s are included for tray attachment. Designed to fit both Series 1 & 2 systems CD Connector System No. Width Fits Standard Hot-Dip Galvanized or Stainless "0424" or "0440" wall penetrations (see page 42.) Sized to fit flange-in or flange-out trays Designed to fit both Series 1 & 2 systems. Makes ladder tray wall penetrations weather resistant to minimize water intrusions. Removable cover/shield fastens to tray and wall penetration sleeve for the utmost in weather protection CD Connector System No. Width 4g CD A Aluminum M Steel, Mill Galvanized ZN Zinc-plated Steel G Steel, Hot-dip Galvanized CD Cadmium-plated Steel ype 304 Stainless Steel ype 316 Stainless Steel ype 316 Stainless Steel V Vinyl *optional Widths (W) in Rail Heights (H) in 35

11 PW Cable ray adder, rough & Solid Bottom Metallic Clamps & Supports Combination Hold down/expansion clamp A Z z-hold down clamp/expansion guide A M G * Works as an expansion guide and flips over for use as a hold down clamp for use with all ladder and ventilated/trough trays. Sold individually : Includes 3 /8" x 1 1 /2" hex bolt, 3 /8" flanged nut : Includes 3 /8" x 1 1 /2" hex bolt, 3 /8" spring nut. Wraps around the tray side rail for use with all solid bottom trays. Can also be used with any flange-in tray system. Expansion guide is slightly taller to permit longitudinal tray movement caused by thermal expansion. Sold individually. HOD DOWN CAMP ZN None ZN None : Includes 1 /4" x 1" carriage bolt, 1 /4" flanged nut ZN EXPANSION GUIDE ZN None ZN a ZN : Includes 1 /4" x 1 1 /2" screw, 1 /4" spring nut ZN Accessory System No. 4a ZN heavy-duty hold down brackets A G Wire mesh-to-adder Clamp Z Designed for use with all trays. 3 /8" diameter hardware for tray attachment only is included. Holes for structure attachment are sized for 1 /2" diameter s. Ideal for vertical tray support. Sold in pairs. his unique clamp allows wire mesh cable tray to be attached to the side rails of any ladder tray and a pre-installed setscrew secures the junction for a permanent installation. Widths (W) in Rail Heights (H) in A845 CD - A845 - WMC 2A CD - WMC 2A - 36

12 I-beam hold down clamp / expansion guide Z single overhead hanger clamp M * Clamp is made of either malleable iron with yellow zinc finish or 316 stainless steel. Hold Down Clamp: Firmly attaches the cable tray to the flange of an I-beam type support. Includes (2) 1 /2" x 5 /8" screws and (1) 1 /2" x 1 1 /2"screw. Expansion Guide: Attaches the clamp to the flange of an I-beam type support, allowing movement of the tray side rail due to thermal contraction and expansion. Includes (1) 1 /2" x 1 1 /2"screw. No drilling is required for either installation. description HOD DOWN CAMP A EXPANSION GUIDE A Z - A s included CD Attaches to the tray bottom flange and supports the cable tray directly from a threaded rod without the need for an additional support member. For use with all series 1 flange-in ladders and ventilated/trough cable trays. hreaded Rod purchased separately. Available for Series 1 only. ROD DIA /2" / 8 " s included ZN M hanger brackets A M G * Nylon Isolation pad N single double Made of extruded black nylon. Can be installed between the cable tray and support member to provide electrical isolation of the tray system. Can also be used to facilitate cable tray movement caused by thermal contraction and expansion. No s required. Supports a single tray side rail from a 1 /2" threaded rod. For use with all flange-out ladder and ventilated/trough tray systems. Safe load = 300 lbs. per bracket. Supports two tray side rails that are installed side-by-side from a single 1 /2" threaded rod. For use with all flange-out ladder and ventilated/trough tray systems. Safe load = 300 lbs. per bracket. YPE singe A836 None DOUBE A837 ZN Connector System No. 4M1 - A837 -ZN SIZE / 8 " x 3" x 6" N A Aluminum M Steel, Mill Galvanized ZN Zinc-plated Steel Z Steel, Zinc-plated G Steel, Hot-dip Galvanized CD Cadmium-plated Steel ype 304 Stainless Steel ype 316 Stainless Steel ype 316 Stainless Steel N Nylon 37

13 PW Cable ray adder, rough & Solid Bottom Metallic Support Hangers, Kits & Brackets single hanger channel A M G Made from 12-gauge strut. Hangers have 9 /16" diameter holes /16" from each end to accept 1 /2" threaded rod. Kit includes s. When used with Z-type hold-down clamps, select hanger with flange out dimensions. 1 5 /8" 3 1 /4" 1 5 /8" 1 5 /8" /16" /16" DIA. Made from 12-gauge struts welded back-to-back. Hangers have 9 /16" dia. holes /16" from each end to accept 1 /2" threaded rod. When used with Z-type hold-down clamps, select hanger with flange out dimensions. /16" 9 /16" DIA. single hanger channel kit* double hanger channel kit* RAY WIDH FANGE IN FANGE OU hanger kit (W+4) (W+10) s included with kit only* ZN RAY WIDH ength M * double hanger channel A M G FANGE IN FANGE OU hanger kit (W+4) (W+10) s included with kit only* ZN ength M * center hanger channel M G Mounts with one 1 /2" threaded rod to allow cable installation from both sides. Cable should be loaded evenly on both sides of the center support to remain level. 12-gauge strut accepts channel nuts for hold down clamps with no drilling required. Not recommended for trays over 24" wide. When used with Z-type hold-down clamps, select hanger with flange out dimensions. 1 5 /8" 1 5 /8" center hanger channel kit* RAY WIDH FANGE IN FANGE OU hanger kit (W+2) (W+6) s included with kit only* ZN ength M * *Kits include hardware for ladder and ventilated/trough trays. Contact egrand/cablofil for other design. 38

14 wall bracket G single strut bracket G /16" 2" Recommended for use with flange-in cable trays. Made with 1 5 /8" x 1 5 /8" x 12 gauge steel struts. 3 1 /8" 4 3 /4" 1 1 /2" 9 /16 DIA. 3 /8" x 1" SOS ON 2" CENERS 7 /8" 2 3 /4" 9 /16" DIA. 2" H H / /2 3 /8" x 1" SOS ON 2" CENERS ength G design load - uniform (BS.) /2" /16" 3 1 /8" 9 /16 DIA. 2" 1 5 /8" 4 3 /4" 0215 design load - uniform (lbs.) ength G /8" double strut bracket G heavy duty strut bracket G " 6" Made with 1 5 /8" x 1 5 /8" x 12 gauge steel struts. /16" 3 1 /8" 2" Made with 1 5 /8" x 1 5 /8" x 12 gauge steel struts. H /16" 4 3 /8" 9 /16" DIA. 2" 3 1 /4" 6" design load - uniform (lbs.) /4" 560 ength t /16" 9 /16" DIA. /16" 3 1 /8" H 2" /16" 9 /16" DIA. 1 5 /8" SIFFENER BAR ON 31" ONG AND GREAER H /8" SIFFENER BAR ON 31" ONG AND GREAER design load - uniform (BS.) ength G A Aluminum M Steel, Mill Galvanized ZN Zinc-plated Steel G Steel, Hot-dip Galvanized CD Cadmium-plated Steel ype 304 Stainless Steel ype 316 Stainless Steel ype 316 Stainless Steel 39

15 PW Cable ray adder, rough & Solid Bottom Metallic Grounding & Conduit Accessories RAY SIDE RAI ground wire attachment clamp 1 1 / 4 RAY SIDE RAI Z 1 1 / 4 conduit bracket clamp Attaches conduit to the cable tray side rail. Z cable clamp For use with all ladder cable trays with box-shaped rungs. conduit dia. EM dia /8"- 1 /2" 1/2" Holds one or two bare copper or aluminum ground wires against the cable tray side rail using included 3 /8 diameter s. his clamp does not bond the ground wire to the tray. cable tray grounding clamp conductor size #6 to # #2, #1 and 1/ /0, 3/0 and 4/0 CD Z Provides an excellent ground for copper or aluminum ground wires to the cable tray. A 1 /4 hex wrench is used to tighten both tray and conductor set screws. Clamps are tin-plated, extruded aluminum. Conductor Range: #6AWG to 250 MCM. s included A ZN A - A ZN A /4" 3/4" " 1" /4" 1 1 /4" /2" 1 1 /2" " 2" /2" 2 1 /2" " 3" " 4" ZN S S4 conduit plate clamp A M Attaches conduit to the ladder tray rungs. Rung Spacing EM dia /2" /4" " /4" /2" " * 2 1 /2" * 3" * 4" s INCUDED 9" Plate 6 9 in 18" plate in * Can also be used with medium-wall (IMC) and thick-wall (rigid) conduit. CD cable size /4" /8" " /8" /4" /8" /2" /8" /4" /8" " /8" /4" /8" /2" /8" /4" /8" " /8" /4" /8" /2" /8" /4" /8" " s INCUDED Rung Spacing 09 - M CD 40

16 clamp bracket M Permits attachment of clamps or other components to the cable tray side rail. Conduit clamps are purchased separately. 11/2 installation s description 21/4 11/ ZN /4"-20 threaded ROD rod coupling nut channel nut with spring channel nut without spring Paraffin impregnated and furnished with 1/4" dia. s. Contact egrand/cablofil with quantities, cable dimensions, cable spacing, and cable tray system information. Can be custom designed for a wide variety of applications. hex nut flanged hex nut s included 0950 As specified slip-on lock nut ZN S4 Allows the user to slip the nut onto a rod, without actually threading it. Ideal for when nuts must be added to a rod, but cannot be threaded due to previously-installed equipment. square channel washer flat, round washer hex head bolt slotted, round-head screw beam clamp no. size SON 1/4 SON 3/8 SON 1/2 1/4"-20 x 6' 3/8"-16 x 12' 1/2"- x 12' 1/4"-20 3/8"-16 1/2"- 1/4"-20 3/8"-16 1/2"- 1/4"-20 3/8"-16 1/2"- 1/4"-20 3/8"-16 1/2"- 1/4"-20 3/8"-16 1/2"- 11/2"w/ 1/4"hole 11/2"w/ 3/8"hole 11/2"w/ 1/2"hole 1/4" 3/8" 1/2" 1/4"-20 x 3/4" 3/8"-16 x 11/2" 1/2"- x 11/2' 1/4"-20 x 3/4" 3/8"-16 x 3/4" 1/2"- x 11/2'" for 1/4" rod for 3/8" rod for 1/2" rod Complete catalog zinc plated ZN DS ZN DS ZN DS ZN DS ZN DS ZN DS ZN DS ZN DS ZN DS ZN DS ZN DS ZN DS ZN DS ZN DS ZN DS ZN DS ZN CD DS CD DS ZN DS ZN DS ZN DS ZN DS ZN DS ZN DS ZN DS ZN DS ZN DS ZN DS ZN DS ZN DS ZN DS ZN* DS ZN** DS ZN*** S8 316 stainless DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS S8 pw c a ble t r ay maple cable blocks SIZE DS DS DS DS DS DS DS DS DS DS DS DS DS * DS ** DS *** Safe oad: *750 lbs.; **1100 lbs.; ***1600 lbs. 3/8"-16 1/2"- SON 3 / 8 - Z N Plastic safety sign A Aluminum M Steel, Mill Galvanized Z Steel, Zinc Plated ZN Zinc-plated Steel Sign measures 8"x12". G Steel, Hot-dip Galvanized CD Cadmium-plated Steel ype 304 Stainless Steel S4 ype 304 Stainless Steel Comp. Cat. no. ype 316 Stainless Steel ype 316 Stainless Steel S8 ype 18-8 Stainless Steel P

17 PW Cable ray adder, rough & Solid Bottom Metallic Firestop Systems Wall penetration sleeve 20" oose collar slides over sleeve after it is placed in the wall M G Product 0440 CD Cadmium-plated Steel 316 Stainless Steel Each cable tray firestop sleeve includes: - One penetration sleeve with flanges - Hilti Fire Blocks - One Hilti Firestop Putty Stick - Hardware for cable tray connection to the wall Cables sleeve: Hilti Fire Blocks Fixed Collar Wall Assembly (Gypsum Wall Shown) AdjustableCollar Metallic and fiberglass cable trays with two side rails: the Firestop kit includes two pairs of splice plates with nuts & bolts. 316 stainless steel is recommended for use with fiberglass systems. Wall Anchors (Not Included) Cable runway systems: two J-bolts with hardware are included for connecting the cable runway to the sleeve. Sleeves are 4" deep for all runway systems. Fabricated cable tray fire stop sleeves from egrand/cablofil, combined with Hilti Firestop s, are an economical alternative to the high cost of fabricating protective fire wall and floor penetration sleeves in the field. Fixed collar is welded to sleeve his firestop system provides a rigid support Cable for trays cable are tray attached in a to U both ends of the sleeve using standard classified system approved for fire wall and splice floor plate penetrations. connectors After the sleeve is placed in the wall or floor, the loose collar slides over it. Hardware for the tray connection only is included. Hardware required to mount sleeves to the wall or floor is not included. he Hilti Fire Block is a compressible 7/16" diameter holes W*+6" fire stop brick, well-suited for for 3/8" hardware (not included) installations where frequent cable changes may be required. Blocks are easily cut to fit any space, and can be removed and reinstalled when cable configurations change. When exposed to fire, the blocks expand to lock the seal in place. H*+6" Penetration Sleeve Fixed collar is welded to sleeve side view 20" W*=Nominal ray Width H*=ray Side Rail Height Cables end view W*+6" Adjustable Collar W*=Nominal ray Width H*=ray Side Rail Height Hilti Fire Blocks Cable trays are attached to both ends of the sleeve using standard splice plate connectors H*+6" oose collar slides over sleeve after it is placed in the wall Fixed Collar 7/16" diameter holes for 3/8" hardware (not included) Floor Assembly Masonry Anchors (Not Included) Penetration Sleeve Outdoor Conversion for Wall Penetration (0434) See page 35. Number of Hilti Fire blocks included with each sleeve SEEVE width Side rail Height (in.) Hilti Fire 4 Blocks Cables Fixed Collar Wall Assembly (Gypsum Wall Shown) AdjustableCollar U classified for use with: Penetration Sleeve 2-hr concrete or block walls 2-hr concrete floors 1-hr gypsum walls 2-hr gypsum walls Wall Anchors (Not Included) Cables Adjustable Collar Hilti Fire Blocks Fixed Collar Penetration Sleeve Floor Assembly Masonry Anchors (Not Included) 42

18 H*+6" H*+6" W*=Nominal ray Width H*=ray Side W*=Nominal Rail Height ray Width H*=ray Side Rail Height Floor Firestop Sleeve Example 0440 used as a floor sleeve per U assembly W and C-AJ-3232 Hilti Fire Blocks Hilti Fire Blocks Wall Assembly (Gypsum Wall Shown) Assembly (Gypsum Wall Shown) AdjustableCollar AdjustableCollar Penetration Sleeve Penetration Sleeve Floor Firestop Sleeve Example 0440 used as a floor sleeve per U assembly F-A-3022 Cables Cables Hilti Fire Blocks Hilti Fire Blocks Fixed Collar Fixed Collar Cables Cables Floor Assembly Floor Assembly Fixed Collar Fixed Collar Wall Anchors (Not Included) Wall Anchors (Not Included) WA/FOOR SEEVE DESCRIPION Designed for single runs of cable tray, having a height and width to match the tray system specified. One end of the 20 inch sleeve has a flange attached 6 inches from the end, while the flange for the other end is floating and is free to slide directly against the face of the wall as needed. he 20 inch length of the sleeve will accommodate a wall thickness of up to 8 inches. A wall thickness of 8 inches will result in the sleeve protruding 6 inches from each side of the wall. Both ends of the sleeve are punched with holes for attaching cable tray splice plates or hardware needed for the tray system specified. INSAAION he opening in the wall should be within 1 inch of the nominal height and width of the cable tray. he flanges of the sleeve have 7 /16" diameter mounting holes for attachment to the wall using 3 /8" diameter hardware. Hardware for wall attachment is not included. After the sleeve is mounted in the wall or floor, the cable trays on either side of the sleeve can be connected using the hardware supplied with the sleeve. When the trays are in place, the cables should be pulled through the wall and sleeve as needed. After all of the cables are installed in the tray, install the Fire Blocks as described. Any voids between cables should be filled with the Firestop Putty Stick. Adjustable Collar Adjustable Collar Masonry Anchors (Not Included) Masonry Anchors (Not Included) Penetration Sleeve Penetration Sleeve ECHNICA DAA Construction...arc Welded Sleeve Dimensions... 20" x ray Width x ray Height Flange Dimensions... (ray Width + 6") x (ray Height + 6") U Classification... Qualifies for use as an equipment grounding conductor per N.E.C Cross-sectional area and amperage ratings are based on the cable tray system attached to the sleeve. HII FIRE BOCKS INSAAION: Walls: Hilti Fire Blocks shall be installed with 5" dimension projecting through and centered within wall assembly. Floors: Hilti Fire Blocks shall be installed with 5" dimension projecting through opening, flush with the top surface of sleeve or recessed within sleeve at any level above the top surface of floor. Fire blocks fill the annular space between the cables and the sleeve. Fire Blocks may be cut to match the profile of cables or to fit opening. Any voids should be filled with 0618 Firestop Putty Stick. wall penetration sleeve catalog Numbering Example: Connector System No. Product No. 6M CD Side Rail Height M G Fitting Series his item must be specified as Series 2. Width 06 6" 09 9" 12 12" 18 18" 24 24" 30 30" 36 36" Fastener Options CD 43

Cable Runways & Accessories

Cable Runways & Accessories SB17U SB13AL SB17 SB17T SB117 SB17HRB SB2107 SB2101A SB17VRB SB2110A SB2129 SB2129SD SB130 SB2221 SB126 SB2118 SB119 SB2105 113 Cooper B-Line manufactures a wide variety of high quality cable pathway products

More information

SECTION 27 05 36 CABLE TRAYS FOR COMMUNICATIONS SYSTEMS

SECTION 27 05 36 CABLE TRAYS FOR COMMUNICATIONS SYSTEMS SECTION 27 05 36 CABLE TRAYS FOR COMMUNICATIONS SYSTEMS PART 1 GENERAL 1.01 DESCRIPTION A. The work covered by this section of the Specifications includes all labor necessary to perform and complete such

More information

C O N V E Y O R C O M P O N E N T S C H A I N S B E L T S B E A R I N G S

C O N V E Y O R C O M P O N E N T S C H A I N S B E L T S B E A R I N G S C O N V E Y O R C O M P O N E N T S C H A I N S B E L T S B E A R I N G S January 2009 Issue 6 Valu Guide Brackets The Ultimate in Adjustability and Cost Savings Valu Guide brackets are part of a family

More information

CT-02 CABLE TRAY SYSTEMS

CT-02 CABLE TRAY SYSTEMS CT-02 CABLE TRAY SYSTEMS SYSTEMS THAT MAKE SENSE Introduction B-Line Systems was formed in 96 and has over 30 years experience manufacturing cable tray systems in which it has grown to become the industry

More information

Guidelines for Earthquake Bracing of Residential Water Heaters

Guidelines for Earthquake Bracing of Residential Water Heaters Guidelines for Earthquake Bracing of Residential Water Heaters Department of General Services Division of the State Architect 1102 Q Street, Suite 5100 Sacramento, CA 95814 Phone: (916) 324-7099 Fax: (916)

More information

CABLE SUPPORT SYSTEMS

CABLE SUPPORT SYSTEMS CABLE SUPPORT SYSTEMS eaturing the CADDY CAT HP J-Hook System Why CADDY CAT HP? Why Choose CADDY CAT HP over tray? ast and Easy to Install Much faster installation compared to conventional cable or ladder

More information

Cat. No. Material Siderail Height. Designed to lock into place for easy alignment and installation. ABW-4-SSP

Cat. No. Material Siderail Height. Designed to lock into place for easy alignment and installation. ABW-4-SSP Metallic Snap-In Splice Plate Designed to lock into place for easy alignment and installation. Packaged in pairs with zinc plated hardware. Provided as standard with each straight and fitting. Cat. No.

More information

SECTION 15140 - PIPE HANGERS AND SUPPORTS

SECTION 15140 - PIPE HANGERS AND SUPPORTS Part I - GENERAL 1.01 SECTION INCLUDES A. The work covered under this section consists of the furnishing of all necessary labor, supervision, materials, equipment, and services to completely execute the

More information

CDGRD-10. Grounding. Solutions For Comm/Data Applications

CDGRD-10. Grounding. Solutions For Comm/Data Applications CDGRD-10 Grounding Solutions For Comm/Data Applications Overview & Table of Contents Cooper B-Line s Grounding products for rack & runway provide a complete solution for grounding metal supports. The offering

More information

SECTION 26 05 49 VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS

SECTION 26 05 49 VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS SECTION 26 05 49 VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS PART 1 - GENERAL 1.1 SUMMARY A. This Section includes seismic restraints and other earthquake-damage-reduction measures for electrical

More information

SECTION 02824 EXPANDED METAL MESH FENCE

SECTION 02824 EXPANDED METAL MESH FENCE SECTION 02824 PART 1 - GENERAL 1.01 DESCRIPTION A. Section includes specifications for expanded metal mesh fence on the right-of-way. 1.02 REFERENCE STANDARDS A. ASTM International (ASTM): 1.03 SUBMITTALS

More information

TECHNICAL MANUAL PIPECLAMP JULY 2013 ROHRVERBINDER ONLINESHOP.DE

TECHNICAL MANUAL PIPECLAMP JULY 2013 ROHRVERBINDER ONLINESHOP.DE TECHNICAL MANUAL PIPECLAMP JULY 2013 ROHRVERBINDER ONLINESHOP.DE Selecting a Fitting fittings are a blackheart malleable casting and are manufactured to BS EN 1562 1997 for the strength requirements. fittings

More information

Cable Supports. Requirements for Cable Supports in the National Electrical Code reads as follows:

Cable Supports. Requirements for Cable Supports in the National Electrical Code reads as follows: QA1 General Information are used to support cables in vertical raceways or risers. Cable supports relieve the strain that would be placed on terminations, the interior of panels, or other devices to which

More information

CP2 Buried Cable Pedestal Initial & Rehab Installation Instructions

CP2 Buried Cable Pedestal Initial & Rehab Installation Instructions Printing 3 March 2008 CP2 Buried Cable Pedestal Initial & Rehab Installation Instructions This instruction is intended for CP2 cable pedestal installations and replacements. The following tools will be

More information

SECTION 23 05 29 - HANGERS AND SUPPORTS FOR HVAC PIPING AND EQUIPMENT

SECTION 23 05 29 - HANGERS AND SUPPORTS FOR HVAC PIPING AND EQUIPMENT SECTION 23 05 29 - HANGERS AND SUPPORTS FOR HVAC PIPING AND EQUIPMENT PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Pipe hangers and supports. 2. Hanger rods. 3. Inserts. 4. Flashing. 5. Equipment

More information

Cable Installation Accessories. Cable Hoisting and Attachment. Snap-In Hangers. SnapStak Hangers

Cable Installation Accessories. Cable Hoisting and Attachment. Snap-In Hangers. SnapStak Hangers SnapStak Hangers New design increases stack height SnapStak hangers have become the industry standard for maximizing space utilization on crowded towers and now that utility is further expanded with the

More information

RPS - sales@rpssolar.com - 858 755 4505-12478 San Bruno Cove, San Diego, CA 92130

RPS - sales@rpssolar.com - 858 755 4505-12478 San Bruno Cove, San Diego, CA 92130 RPS - sales@rpssolar.com - 858 755 4505-2478 San Bruno Cove, San Diego, CA 9230 SWH Solar Mount Rail R-MR-SW-SR-0.5, R-MR-SW-SR-2, R-MR-SW-SR-4, R-MR-SW-SR-4B, R-MR-SW-SR-7 Part No. MR-SW-SR-0.5, MR-SW-SR-2,

More information

Salter Industries, Spiral Stair

Salter Industries, Spiral Stair Salter Industries, Spiral Stair Adjustable Stair Installation Instructions TOOLS NEEDED: 1. Electric drill with hex chuck and Phillips bit 2. Drill bits 1/8", 1/4", 3/16", 3/8" 3. Socket Set 4. Tape Measure

More information

SECTION 710 GUARDRAIL MATERIALS

SECTION 710 GUARDRAIL MATERIALS 710.08 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 SECTION 710 GUARDRAIL MATERIALS 710.01 General. Metal beam

More information

Two most common lock nut groups: 1-Prevailing Torque Type Lock Nuts:

Two most common lock nut groups: 1-Prevailing Torque Type Lock Nuts: Two most common lock nut groups: 1. PREVAILING TORQUE a design feature of the lock nut produces friction between threads of mated components thereby increasing the force needed to tighten as well as loosen

More information

Bands. REGULAR BRACE BANDS 12 GA. x 3/4 Galvanized. REGULAR TENSION BANDS 14 GA. x 3/4 Galvanized Sack Weight Price Each

Bands. REGULAR BRACE BANDS 12 GA. x 3/4 Galvanized. REGULAR TENSION BANDS 14 GA. x 3/4 Galvanized Sack Weight Price Each Bands REGULAR TENSION BANDS 14 GA. x 3/4 Galvanized Sack Weight Item# Qty. Less Sack Sack 1 3/8" 1 250.12 lbs..36.30 1 5/8" 2 250.14 lbs..38.32 1 7/8" 3 250.16 lbs..40.33 2 3/8" 4 250.22 lbs..42.35 2 7/8"

More information

Electrical Accessories

Electrical Accessories Electrical ccessories Electrical ccessories complete system of top quality, time saving products, designed for surface metal raceways, lighting and cable supports. Innovative designs offer many installation

More information

Guidelines for Earthquake Bracing Residential Water Heaters

Guidelines for Earthquake Bracing Residential Water Heaters Guidelines for Earthquake Bracing Residential Water Heaters Department of General Services Division of the State Architect In accordance with the Health and Safety Code Section 19215, the Division of the

More information

INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks

INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks Securitron Magnalock Corp. www.securitron.com ASSA ABLOY, the global leader Tel 800.624.5625 techsupport@securitron.com in door opening solutions INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate

More information

SECTION 32 31 13 CHAIN LINK FENCES AND GATES

SECTION 32 31 13 CHAIN LINK FENCES AND GATES SECTION 32 31 13 CHAIN LINK FENCES AND GATES PART 1 GENERAL 1.1 SUMMARY A. Section Includes: 1. Fence framework, fabric, and accessories. 2. Excavation for post bases. 3. Concrete foundation for posts

More information

SPIRAL STAIR KIT INSTALLATION MANUAL

SPIRAL STAIR KIT INSTALLATION MANUAL SPIRAL STAIR KIT INSTALLATION MANUAL Effective January 1, 2014 If you have any questions, please call the location that your Stair Kit was purchased from: Broomall, Pennsylvania 1-800-52-7427 Ontario,

More information

I BEAM TRACK INSTALLATION

I BEAM TRACK INSTALLATION PDQ 0/700 FESTOON SYSTEM INSTALLATION AND MAINTENANCE INSTRUCTIONS INTRODUCTION The PDQ Festoon System was designed to run on one of three sizes of I-beams: S x., S8 x 8. and S x.. System trolleys must

More information

All Copper Alloy Ground Connectors

All Copper Alloy Ground Connectors MA6 Type ABG For cable connection parallel or at right angles to pipe or rod. Conduit MA6 Conduit Features: A high strength corrosion-resistant copper alloy ground connector connecting a ground wire either

More information

PV MOUNTING SYSTEMS INSTALLATION GUIDE

PV MOUNTING SYSTEMS INSTALLATION GUIDE PV MOUNTING SYSTEMS INSTALLATION GUIDE PV MOUNTING SYSTEMS INSTALLATION GUIDE In this guide we demonstrate the installation of PV Mounting Rail and PV Panels on different roof types, using a Solar Adjustable

More information

CABLEVIEW RAILING INSTRUCTIONS

CABLEVIEW RAILING INSTRUCTIONS CUSTOMER SERVICE CONTACT INFO Phone: 888-686-7245(RAIL) Fax: 888-686-7245 (RAIL) Email: sales@stainlesscablerailing.com Website: www.stainlesscablerailing.com Address: 3315 NE 112 th Ave #72/73, Vancouver,

More information

SECTION 25110 TELECOMMUNICATION ROOMS

SECTION 25110 TELECOMMUNICATION ROOMS PART 1 - GENERAL 1.1 SUMMARY A. SCOPE SECTION 25110 TELECOMMUNICATION ROOMS 1. This section includes the minimum installation requirements for equipment and cabling infrastructure in Telecommunication

More information

FASTENERS SELECTION GUIDE

FASTENERS SELECTION GUIDE FASTENERS SELECTION GUIDE Choose from our most popular range of fasteners We have over 9,000 fasteners, fixings, ironmongery and hardware products online June 2016 uk.rs-online.com (UK customers) www.rs-components.com

More information

The Manitoba Water Services Board SECTION 027110 Standard Construction Specifications September 2013 Page 1 of 12

The Manitoba Water Services Board SECTION 027110 Standard Construction Specifications September 2013 Page 1 of 12 September 2013 Page 1 of 12 Part 1 General 1.1 DESCRIPTION OF WORK.1 The work shall consist of the supply and construction of a chain link fence, barb wire fences or mesh fences as shown on the Plans or

More information

Policy on Water Heater Installations Policy No. UPC 510-1-94 Effective: September 1, 1995 Revised: February 10, 1996

Policy on Water Heater Installations Policy No. UPC 510-1-94 Effective: September 1, 1995 Revised: February 10, 1996 CITY OF SAN JOSE BUILDING DIVISION POLICY Policy on Water Heater Installations Policy No. UPC 510-1-94 Effective: September 1, 1995 Revised: February 10, 1996 All new and replacement water heaters installed

More information

FRONT BUMPER INSTALLATION INSTRUCTIONS 2007-2011 DODGE / MERCEDES SPRINTER

FRONT BUMPER INSTALLATION INSTRUCTIONS 2007-2011 DODGE / MERCEDES SPRINTER Aluminess Products Inc 9402 Wheatlands Ct. #A Santee, CA 92071 619-449-9930 FRONT BUMPER INSTALLATION INSTRUCTIONS 2007-2011 DODGE / MERCEDES SPRINTER Please read before beginning Stainless steel hardware

More information

SECTION 02832 CHAIN LINK FENCE AND GATES

SECTION 02832 CHAIN LINK FENCE AND GATES SECTION 02832 CHAIN LINK FENCE AND GATES PART 1 GENERAL 1.01 SECTION INCLUDES A. Fabrication, furnishing and installation of chain link fence, chain link gates, and extension brackets with barbed wire.

More information

MATERIAL SPECIFICATIONS

MATERIAL SPECIFICATIONS FENCING - 1 2-11-1 CHAIN LINK FENCE AND GATE(S) A. SCOPE MATERIAL SPECIFICATIONS This section covers the work necessary for the chain link fence gate(s), complete. General Like items of materials provided

More information

STERNMOUNT MARINE TOWER KIT OWNER S MANUAL

STERNMOUNT MARINE TOWER KIT OWNER S MANUAL STERNMOUNT MARINE TOWER KIT OWNER S MANUAL VERSION 1.5 Made in the USA by: Southwest Windpower 1801 W. Route 66 Flagstaff, AZ 86001 (520) 779-9463 AIR Marine is a trademark of Southwest Windpower Inc.

More information

18 AWG thru 8 AWG Not greater than 100/30 100/30. 6 AWG thru 1/0 AWG Not greater than 200/60 100/30

18 AWG thru 8 AWG Not greater than 100/30 100/30. 6 AWG thru 1/0 AWG Not greater than 200/60 100/30 Commercial Products COMMERCIAL PRODUCTS: RIGID AND IMC FITTINGS s Used to support cables in vertical raceways or risers. Relieves the strain that would be placed on terminations, the interior of panels,

More information

1036 Parkway Ct. Phone: 770-932-0202 Buford, GA 30518 Fax: 770-945-0041

1036 Parkway Ct. Phone: 770-932-0202 Buford, GA 30518 Fax: 770-945-0041 CONSTRUCTION 1. A. GENERAL 1.A.1. The intent of this specification is to set forth construction and design standards that will result in an installation of modular cabinetry requiring FLUSH OVERLAY CONSTRUCTION.

More information

Dock Hardware & Accessory Products Catalog

Dock Hardware & Accessory Products Catalog Dock Hardware & Accessory Products Catalog Product Page # Product Page # Angle Brackets/Clips 8 Back Up Plate 5 Backing Plate/Hurricane Stop 10 Carriage Bolt Sets 4 Chain Retainer 10 Connector Pin Set

More information

Parts List. Safety Information. Additional Considerations. Retractable Security Cover Kit. Rocky Roller Kit

Parts List. Safety Information. Additional Considerations. Retractable Security Cover Kit. Rocky Roller Kit Parts List Retractable Security Cover Kit 3" PVC pipe with (4) 7'4" lengths of track (longer pools will have additional track pieces) Leading edge Optional cover pump (for outdoor installations) Rocky

More information

SPECIFICATION STANDARD GROUNDING AND BONDING

SPECIFICATION STANDARD GROUNDING AND BONDING PART 1: GENERAL 1.01 SCOPE OF WORK SPECIFICATION STANDARD A. The grounding and bonding system refers to all electrodes required by NEC, as well as including made, supplementary, information technology

More information

MGB Chrome Bumper Conversion

MGB Chrome Bumper Conversion MGB Chrome Bumper Conversion Installation Instructions For 1974 1/2-1980 MGB This kit requires cutting, welding, and painting. Professional installation recommended. Note: Every MGB body is slightly different

More information

NEMA Standards Publication VE 2-2000. Cable Tray Installation Guidelines

NEMA Standards Publication VE 2-2000. Cable Tray Installation Guidelines NEMA Standards Publication VE 2-2000 Cable Tray Installation Guidelines Published by: National Electrical Manufacturers Association 1300 North 17th Street Rosslyn, VA 22209 Approved by: Cable Tray Institute

More information

VersaRack Installation Instructions. masterack. Tools Required:

VersaRack Installation Instructions. masterack. Tools Required: masterack Versaack Installation Instructions ll of us at asterack wish to thank you for your purchase of the Versaack. We are proud of this product and hope that you fi nd it a functional as well as a

More information

Instructions for Retrofitting T.M. Cobb and El and El Pocket Door Frames (recommended for 2x4 and 2x6 walls)

Instructions for Retrofitting T.M. Cobb and El and El Pocket Door Frames (recommended for 2x4 and 2x6 walls) Instructions for Retrofitting T.M. Cobb and El and El Pocket Door Frames (recommended for 2x4 and 2x6 walls) The Peterson Pocket Door System has been engineered to function in T.M. Cobb (www.tmcobb.com)

More information

SECTION CHAIN LINK FENCE AND GATES

SECTION CHAIN LINK FENCE AND GATES SECTION 02830 CHAIN LINK FENCE AND GATES PART 1 GENERAL 1.01 SCOPE OF WORK The work covered in this section shall include all materials, labor, and equipment necessary for a complete installation of the

More information

G-2. Space Management. Above the Desk Space Management. Tool Bars

G-2. Space Management. Above the Desk Space Management. Tool Bars Space Management Above the Desk Space Management Custom Accents Space Management is designed to create added workspace for the office environment. By placing often used desk items in easy to access storage

More information

WHI 90-Minute Rated Veneered Door Frame Installation Instructions

WHI 90-Minute Rated Veneered Door Frame Installation Instructions No. 940-03-10 INSTALLATION INSTRUCTIONS 90 MINUTE RATED VENEERED DOOR FRAME DOOR REQUIREMENTS: Consult the door manufacturer to make sure that the doors are qualified for the hardware to be installed,

More information

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS PLEASE READ COMPLETE INSTRUCTIONS BEFORE YOU BEGIN LEAVE INSTALLATION INSTRUCTIONS AND USER'S GUIDE WITH OWNER ALL ELECTRIC WIRING AND PLUMBING MUST BE DONE

More information

SECTION 260536 - CABLE TRAYS. A. Continuous, rigid, welded steel or stainless steel wire mesh cable management system.

SECTION 260536 - CABLE TRAYS. A. Continuous, rigid, welded steel or stainless steel wire mesh cable management system. SECTION 260536 - CABLE TRAYS PART 1 - GENERAL SECTION INCLUDES: A. Continuous, rigid, welded steel or stainless steel wire mesh cable management system. B. Cable tray systems are defined to include, but

More information

Cat. No. Finishes & Materials. Standard Finish: Electrogalvanized. Change suffix to SS6(C).

Cat. No. Finishes & Materials. Standard Finish: Electrogalvanized. Change suffix to SS6(C). Superstrut Support Systems 1-5/8 in. x 1-5/8 in. Channel and Hardware Superstrut 1-5/8 in. x 1-5/8 in. - 12 Gauge Channel Type A Solid Base Punched Description Solid base -P Punched -HS Half slots Half

More information

Cable Support Solutions

Cable Support Solutions Cable Support Solutions B-Line by Eaton Technology Day Japan 2013 2012 Eaton Corporation. All rights reserved. 2012 Eaton Corporation. All rights reserved. 2012 Eaton Corporation. All rights reserved.

More information

Galvanized Pipe. Standard pipe is 16 gauge galvanized construction. Standard lengths are five feet and 20 feet. Heavier gauges are also available.

Galvanized Pipe. Standard pipe is 16 gauge galvanized construction. Standard lengths are five feet and 20 feet. Heavier gauges are also available. Galvanized Pipe Standard pipe is 16 gauge galvanized construction. Standard lengths are five feet and 20 feet. Heavier gauges are also available. Angle rings are needed to secure connections. See pages

More information

ELECTRIC METERING COMMERCIAL & INDUSTRIAL

ELECTRIC METERING COMMERCIAL & INDUSTRIAL ELECTRIC METERING COMMERCIAL & 1.0 INDEX 1.0 INDEX 2.0 SCOPE 3.0 GENERAL REQUIREMENTS 4.0 METER LOCATIONS 5.0 UNDERGROUND TERMINATIONS 6.0 METERING TRANSFORMER ENCLOSURES 7.0 SINGLE CUSTOMER METER INSTALLATIONS

More information

glass & Glazing Products

glass & Glazing Products glass & Glazing Products WallMaker Create an unlimited variety of bright, beautiful and secure interior environments with the easy-to-install Stylmark WallMaker glass wall system. This versatile system

More information

HI-LINE UTILITY SUPPLY CO. Phone: Fax:

HI-LINE UTILITY SUPPLY CO. Phone: Fax: 152 PINS FOR 1" INSULATORS - For Wood CrossArms - Long Shank w/ nut, washer & lock nut Cat. No. Dia. Shoulder Pin Length O.A. Length 881 10-3/4" 881A 5" 11-1/2" 883 2" 12-1/2" 884 11-3/4" PINS FOR 1" INSULATORS

More information

INSTALLATION INSTRUCTIONS 65-72 F-100 4-Link Rear End

INSTALLATION INSTRUCTIONS 65-72 F-100 4-Link Rear End INSTALLATION INSTRUCTIONS 65-72 F-100 4-Link Rear End Please read these instructions completely before starting your installation. Assemble suspension on vehicle before powder-coating to ensure proper

More information

ANTENNA PARTS CATALOG

ANTENNA PARTS CATALOG ANTENNA PARTS CATALOG Maco Antennas 302 S. East St. Mt. Carroll, IL 61053 www.macoantennas.net 815-244-3500 www.antennapartsoutlet.com SCREWS / BOLTS PART SIZE LENGTH DESCRIPTION PRICE S21 10-24 1/2" Machine

More information

SunPower Installation Manual

SunPower Installation Manual SunPower SM System Planning and Assembly SunPower Table of Contents Part I. Scope, components, and installer responsibility...2 Part II. Installing SM System with top mounting clamps...4 Part III. Installing

More information

WORKPLACE SHELVING STORAGE RACKS SHOP FURNITURE & SPECIALTY STORAGE

WORKPLACE SHELVING STORAGE RACKS SHOP FURNITURE & SPECIALTY STORAGE WORKPLACE SHELVING STORAGE RACKS SHOP FURNITURE & SPECIALTY STORAGE Look to Tri-Boro for: Outstanding Quality Affordable Pricing & Ontime Delivery Online PDF Catalog Pages Tri-Boro Shelving and Partition

More information

Packaged Terminal Air Conditioner Wall Sleeve Installation

Packaged Terminal Air Conditioner Wall Sleeve Installation Installation & Maintenance Data IM 1196 Group: PTAC Part Number: 910141799 Date: October 2013 Packaged Terminal Air Conditioner Installation x 42" PGAN with Top-Mounted Hydronic Heat Note: Installation

More information

K.D. LOCKER ASSEMBLY INSTRUCTIONS

K.D. LOCKER ASSEMBLY INSTRUCTIONS K.D. Locker Assembly Instructions PN 80 K.D. LOCKER (Content Update 8/0) ASSEMBLY INSTRUCTIONS These Instructions Cover 3 Types of Lockers: VANGUARD, GUARDIAN AND INVINCIBLE II Contents General Instructions

More information

Installation Instructions

Installation Instructions READ BEFORE INSTALLING UNIT For Through-the-Wall Air Conditioners To avoid risk of personal injury, property damage, or product damage due to the weight of this device and sharp edges that may be exposed:

More information

Prefabricated FRP Lift Station Sample Specifications Section 1 General

Prefabricated FRP Lift Station Sample Specifications Section 1 General Section 1 General 1. Description 1.1 Scope of Work: Contractor shall furnish all labor, materials, equipment and performance of all work necessary or incidental to furnish and install a simplex/duplex

More information

Install Manual GC Standing Seam Roof System Rail Seam Mount

Install Manual GC Standing Seam Roof System Rail Seam Mount Install Manual GC Standing Seam Roof System Rail Seam Mount CONTENTS I II III IV V VI VII VIII IX GENERAL MATERIALS AND TOOLS REQUIRED SYSTEM COMPONENTS INSTALLATION OF SYSTEM SYSTEM OVERVIEW MATERIALS

More information

3. SEISCO PARTS & SERVICE REMOVAL AND REPAIR GUIDE

3. SEISCO PARTS & SERVICE REMOVAL AND REPAIR GUIDE 4 3. SEISCO PARTS & SERVICE REMOVAL AND REPAIR GUIDE A. Changing the Control Board B. Replacing a Heating Element C. Thermistor Replacement D. High Limit Switch Replacement E. Level Detector Replacement

More information

POWERS Controls. Technical Instructions Document No P25 AP March 5, No. 6 Pneumatic Damper Actuator.

POWERS Controls. Technical Instructions Document No P25 AP March 5, No. 6 Pneumatic Damper Actuator. POWERS Controls No. 6 Pneumatic Damper Actuator Technical Instructions AP 331-3 Description 331-2793 Actuator 331-2857 Actuator 331-3012 Extended Shaft and Frame with Clevis and Pin Mounting The POWERS

More information

Poly-Classic Composite Railing Installation Instructions

Poly-Classic Composite Railing Installation Instructions Poly-Classic Composite Railing Installation Instructions Poly-Classic Composite Railing Systems come in three styles: Colonial, Craftsman, and Craftsman Over The Post (OTP), and in either level or stair

More information

DIMENSIONAL BOLTING CATALOG

DIMENSIONAL BOLTING CATALOG DIMENSIONAL BOLTING CATALOG DIMENSIONAL CATALOG Table of Contents Page Screws Round Head Screws 1-1 Various Head Styles Machine Scerws 1-2 to 1-23 Tapping Screws (Approx. Hole Sizes) 1-24 Thumb and Wing

More information

FLEXTRAY - Hanging Support Methods

FLEXTRAY - Hanging Support Methods 18 Eaton s B-Line series FLEXTRAY Wire Basket Accommodates 1 /4" and 3 /8" rod sizes Installs quickly with a screwdriver or pliers thus reducing installation time Requires only one hex nut (not included)

More information

Installation Manual. SKU# 21000 series (Base Rails) SKU# 22000 series (Overhead Racks)

Installation Manual. SKU# 21000 series (Base Rails) SKU# 22000 series (Overhead Racks) Installation Manual SKU# 21000 series (Base Rails) SKU# 22000 series (Overhead Racks) Welcome to the world of TracRac! We re delighted that you have chosen TracRac, the ultimate sliding truck rack system.

More information

Installation Instructions Kit, Base Rail Bracket Part # 31404

Installation Instructions Kit, Base Rail Bracket Part # 31404 Installation Instructions Kit, Base Rail Bracket Part # 31404 Dealer / Installer: Provide a copy of these Instructions to the end user of this product. These Instructions. provide important operating and

More information

SECTION 32 31 00 EXPANDED METAL FENCING Meets Buy American Procurement

SECTION 32 31 00 EXPANDED METAL FENCING Meets Buy American Procurement PART 1 GENERAL SECTION 32 31 00 EXPANDED METAL FENCING Meets Buy American Procurement 1.1 SUMMARY A. Section Includes 1. Supply and install all materials and accoutrements required for the installation

More information

Installation Manual Box Rail Series

Installation Manual Box Rail Series Installation Manual Box Rail Series INTRODUCTION THANK YOU for purchasing Real Sliding Hardware. Our hardware will add a stunning accent to your living environment and maximize its space. It is made with

More information

K. D. FRAME ASSEMBLY FOR CLOSED STEEL STUD WALLS...Ins 10. FRAME INSTALLATION DETAILS FOR CLOSED STEEL STUD WALLS...Ins 11

K. D. FRAME ASSEMBLY FOR CLOSED STEEL STUD WALLS...Ins 10. FRAME INSTALLATION DETAILS FOR CLOSED STEEL STUD WALLS...Ins 11 K. D. FRAME ASSEMBLY FOR MASONRY WALLS...........................Ins 2 FRAME INSTALLATION DETAILS FOR MASONRY WALLS......................Ins 3 INSTALLING EXISTING MASONRY WALL ANCHORS IN FRAME..................Ins

More information

TIE DOWNS CARGO CONTROL

TIE DOWNS CARGO CONTROL 138 620 Spicer St., Akron, OH 44311 800.824.1864 3415 S.W. 6th St., Ocala, FL 34474 800.682.8900 620 Spicer St., Akron, OH 44311 800.824.1864 3415 S.W. 6th St., Ocala, FL 34474 800.682.8900 139 140 620

More information

1. Division-5 Section Metal Fabrications for material and welding requirements related to wrought iron fencing.

1. Division-5 Section Metal Fabrications for material and welding requirements related to wrought iron fencing. SECTION 02835 SITE FENCES AND GATES PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of Contract, including General and Supplementary Conditions and Division 1 Specification Sections,

More information

INSTRUCTIONS THOROUGHLY BEFORE BEGINNING***************

INSTRUCTIONS THOROUGHLY BEFORE BEGINNING*************** Bill of Materials: RAC0012 Green Wing Aerodynamic Skirt Kit Item Part Number Description Quantity 1 RMC0218 Gen 2 Trailer Skirt Roadside 1 2 RMC0219 Gen 2 Trailer Skirt Curbside 1 3 RMC0041 Trailer Skirt

More information

Elo Touch Solutions Wall-mounting Kit for the 5501L IDS Touchmonitors

Elo Touch Solutions Wall-mounting Kit for the 5501L IDS Touchmonitors Installation Manual Elo Touch Solutions Wall-mounting Kit for the 5501L IDS Touchmonitors SW602206 Rev B Table of Contents Chapter 1: Safety Warning... 3 Chapter 2: Kit Contents... 4 Included in Kit...

More information

RAIL FREE SOLAR ROOF MOUNT

RAIL FREE SOLAR ROOF MOUNT RAIL FREE SOLAR ROOF MOUNT Utilizes EcoFasten Solar s patented technology Rock-it system Designed with the installer in mind. EcoFasten Solar specializes in solar roof attachments that are the easiest

More information

Ladder Leveling and Stabilizing System Type IAA, 375-Pound Duty Rating

Ladder Leveling and Stabilizing System Type IAA, 375-Pound Duty Rating LeveLok Model LL-STB-1 Ladder Leveling and Stabilizing System Type IAA, 375-Pound Duty Rating INSTALLATION AND OPERATION INSTRUCTIONS CONTENTS Installation on Aluminum Ladders... 2 Installation on Fiberglass

More information

SECTION 15076 CEMENT-MORTAR LINED AND COATED STEEL PIPE

SECTION 15076 CEMENT-MORTAR LINED AND COATED STEEL PIPE SECTION 15076 CEMENT-MORTAR LINED AND COATED (CML&C) STEEL PIPE PART 1 GENERAL 1.01 DESCRIPTION This section designates the requirements for steel pipe fabrication, test in shop, installation of steel

More information

ENGINEERING SPECIFICATION PULTRUDED DYNARAIL FIBERGLASS LADDER & LADDER CAGES

ENGINEERING SPECIFICATION PULTRUDED DYNARAIL FIBERGLASS LADDER & LADDER CAGES ENGINEERING SPECIFICATION PULTRUDED DYNARAIL FIBERGLASS LADDER & LADDER CAGES PART 1 - GENERAL 1.1 SCOPE OF WORK SECTION 06610 FIBERGLASS REINFORCED PLASTICS (FRP) FABRICATIONS PULTRUDED SQUARE TUBE LADDER

More information

PIPE & CONDUIT CLAMPS

PIPE & CONDUIT CLAMPS PIPE & ONDUIT LMPS Power-Strut pipe, conduit and tubing clamps are formed in punch press dies in a wide selection of sizes to meet every requirement. MTERIL: Power-Strut pipe, conduit and tubing clamps

More information

Contractors Guide Central Inverter System Installation

Contractors Guide Central Inverter System Installation Contractors Guide Central Inverter System Installation Step By Step Procedures 2,200 Watt/VA 6 Step Installation 1. Mount Bottom Cabinet 2. Mount Top Cabinet 3. Install Batteries 4. Install Conduit 5.

More information

EZ-48-3AB-125-35 Weather Station Mounting Tripod and Mast

EZ-48-3AB-125-35 Weather Station Mounting Tripod and Mast EZ-48-3AB-125-35 Weather Station Mounting Tripod and Mast EZ-125-35M 35 Mast Extension (Optional) EZ-125-SK Stake Kit (Optional) EZ-46-3 Tar Pad Kit (Optional) EZ-GWA Guy Wire Kit (Optional) Ambient Weather

More information

HORIZONTAL INSTALLATION

HORIZONTAL INSTALLATION THERMO/SOLAR Žiar s.r.o. MANUAL FOR INSTALLATION PV SUPPORTING FRAMES HORIZONTAL INSTALLATION Technical alternation reserved A1410 1 12/2014 CONTENT ORD.NO. PAGE Mounting information 3 Mounting, flat roof

More information

CLEAR-DIVISIONS CENTERFOLD

CLEAR-DIVISIONS CENTERFOLD CLEAR-DIVISIONS CENTERFOLD Introduction: The following three (3) part specification offers the Standard and Optional features for the CLEAR-DIVISIONS CENTERFOLD moveable The yellow highlighted areas in

More information

POD Visor Instructions

POD Visor Instructions POD Visor Instructions Please read fully before beginning assembly and mounting the Visor Parts List - Visor Left Part (LV), Visor Right Part (RV) Qty 2, Aluminum Crossbars Hardware - Qty 17, 1/4" X 3/4"

More information

Installation Manual For FE26 Iron Railing. Call for Installation Support. Extra Screws Included

Installation Manual For FE26 Iron Railing. Call for Installation Support. Extra Screws Included Installation Manual For FE Iron Railing Call 1-800-335-5909 for Installation Support Extra Screws Included Fortress Fe 2 Post Mounting Applications (USA) It is the responsibility of the installer to meet

More information

HALE PET DOOR INSTALLATION INSTRUCTIONS HALE STANDARD PANEL MODEL

HALE PET DOOR INSTALLATION INSTRUCTIONS HALE STANDARD PANEL MODEL HALE PET DOOR INSTALLATION INSTRUCTIONS HALE STANDARD PANEL MODEL Please read these instructions carefully and completely before attempting to install Hale Pet Doors; they will guide you through the steps

More information

STEADYfast Stabilizer Installation Notes Fifth Wheel and Travel Trailers 11/23/13

STEADYfast Stabilizer Installation Notes Fifth Wheel and Travel Trailers 11/23/13 STEADYfast Stabilizer Installation Notes Fifth Wheel and Travel Trailers 11/23/13 (See Supplemental Instructions for trailers with heavy duty round footplates and/or Power Leveling Systems) PHONE SUPPORT

More information

All-Season Sunroom Sliding Glass Door Installation Instructions

All-Season Sunroom Sliding Glass Door Installation Instructions ASRESGD-08 All-Season Sunroom Sliding Glass Door Installation Instructions Panel Frame Door Frame Left Side Foam Insulator IE241 H Bar Assembly Door Frame Top Track Panel Frame Door Frame Right Side Stationary

More information

NORTH ORANGE COUNTY COMMUNITY COLLEGE DISTRICT SECTION 27 05 26 GROUNDING AND BONDING FOR COMMUNICATION SYSTEMS

NORTH ORANGE COUNTY COMMUNITY COLLEGE DISTRICT SECTION 27 05 26 GROUNDING AND BONDING FOR COMMUNICATION SYSTEMS SECTION GROUNDING AND BONDING FOR COMMUNICATION SYSTEMS RELATED SECTIONS: Section 27 00 00 General Requirements Section 27 02 00 Communication General Requirements Section 27 05 28 Pathways for Communications

More information

POWERS Controls No. 4 Pneumatic Damper Actuator

POWERS Controls No. 4 Pneumatic Damper Actuator POWERS Controls No. 4 Pneumatic Damper Actuator Technical Instructions Document No. 155-032P25 AP 331-2 Actuator Assembly 331-2929 Typical Actuator Assembly 331-2904 Typical Actuator Assembly 331-3000

More information

1E EJB Junction Boxes Cl. I, Div. 1 and 2, Groups B, C, D

1E EJB Junction Boxes Cl. I, Div. 1 and 2, Groups B, C, D EJB Junction Boxes Cl. I, Div. and 2, Groups B, C, D Cl. II, Div., Groups E, F, G Cl. II, Div. 2, Groups F, G Cl. III NEMA 3, 4, 4X*,, Ex d IIB + H2 T6, IP66 Explosionproof Dust-Ignitionproof Raintight

More information

Removable Aluminium posts

Removable Aluminium posts Post Solent Sail Shades Ltd 120 Billington Gardens Hedge End Southampton SO30 2RT Tel/Fax: 01489 788243 www.solentsailshades.co.uk Email: info@solentsailshades.co.uk Removable Aluminium posts Single Pole

More information

Window Installation Instructions

Window Installation Instructions Caution The correct installation methods of windows in full frame or insert applications is critical towards achieving the tested performance of the window and longterm enjoyment and energy savings for

More information