IRMA MATRIX M12 components for Ethernet installations
|
|
- Francine Tyler
- 7 years ago
- Views:
Transcription
1 Automatic passenger counting IRMA Infrared Most Accurate 5 th Generation IRMA MATRIX M12 components for Ethernet installations Customer documentation iris-gmbh Ostendstrasse Berlin Germany Rev Subject to alterations
2 2/24 IRMA MATRIX M12 components for Ethernet installations Document information Title of document: IRMA MATRIX M12 components for Ethernet installations File name: KDKT_IRMA-MATRIX_M12-Components_ETH_1.0_en Responsible: Technical Centre Revision: 1.0 Edition (YYYY-MM): Type of document: Customer documentation Status: Document history Rev. Date Name Notes / modifications Jan VEGI - First release Validity Sensors covered by this document Sensor line Sensor designation Description IRMA MATRIX DIST500.7-A07.OC??? Surface mount version IRMA MATRIX DIST500.7-F07.OC??? Flush mount version
3 3/24 IRMA MATRIX M12 components for Ethernet installations Contents 1 General On this document Symbols / abbreviations used Cable qualities available:, M12 components for Ethernet installations A typical installation example IRMA MATRIX sensors with Ethernet communication - Connection example scon connector for Ethernet connection scon with an open power supply connection scon connector with power supply via the CAN connection M12 system cable for Ethernet (CAT5) Power supply cable for switch M1-RJ45 adapter cable for connecting a laptop Identification Example of cable marking by printed inscription Marking of cable with label (heat-shrinkable sleeve) Example of marking on the package Technical data/properties Connector Cable properties Ethernet cable Power cable at scon connector CAN cable at scon connector Switch cable Annex Engineering drawings of the connectors M12 connector (m) M12 connector (f) RJ45 connector (m)... 24
4 4/24 IRMA MATRIX M12 components for Ethernet installations 1 General 1.1 On this document The M12 components described in this catalogue serve to connect IRMA MATRIX sensors to the Ethernet communication system. This catalogue is a means for planning and preparation of IRMA MATRIX sensor installations in Ethernet networks. It comprises the technical data of the required components in a clearly arranged form. For the installation in the vehicle please observe the "IRMA-MATRIX Installation manual Ethernet" and the data sheets of the scon connectors used. 1.2 Symbols / abbreviations used "Please note" "Caution" - can result in defects! Connector (f) Connector (m) Art. No. K-M12CAT5-03-1m see p. 9 Female connector Male connector Article Number (Part Number) iris Article designation Link to detailed description TO CONNECTION EXAMPLE, P. 6 This document uses specially identified links enabling the navigation from an overview to the detailed description of the individual component and back again. They look like you can see on the left: blue letters, bold type, underlined and with colored shading.
5 5/24 IRMA MATRIX M12 components for Ethernet installations 1.3 Cable qualities available:, M12 cables are available in different cable qualities which are identified with and in this catalogue: Halogen-free The cable is halogen-free acc. to VDE or if acc. to EN or IEC a halogen acid gas content of 0.5% is measured or if acc. to EN a ph level of 4.3 and a specific conductivity of 10 µs/mm are measured. Cables for increased fire protection The cable is halogen-free as specified in the standards given in section. The cable meets the requirements of fire condition 4 for indoor use as specified in DIN : M12 components for Ethernet installations 2.1 A typical installation example In the following a typical example for the installation of IRMA MATRIX sensors with communication via Ethernet is presented. For the sake of clarity the type of the connectors is marked by the color and type of its representation: M12 connector (m): contour shown in blue M12 connector (f): representation by the surface filled in red The legend contains LINKS taking the user to the component's data sheet.
6 6/24 IRMA MATRIX M12 components for Ethernet installations IRMA MATRIX sensors with Ethernet communication - Connection example RJ45 connection for service laptop 1 IRMA-MATRIX sensor 2 scon connector for Ethernet connection scon-s-eth-22--x-y () 1 scon-s-eth-22--x-y () 1 see page 7 3 M12 Ethernet connecting cable K-M12CAT5-03-xm () 1 x (in m) = 1/2/10/20 K-M12CAT5-04-xm () 1 x (in m) = 1/2/10/20 see page 8 4a Switch: Switch-M12-5Port-eCon 5 Power supply cable for switch K-Switch-Power () 1 SAC-4P-5,0-28R/FS SCO Rail () 1 ; see page 10 6 Adapter cable for service laptop see page 11 A B Distribution of the vehicle-provided power supply to each door for connecting sensors and the switch. The distribution of the vehicle-provided power supply to each door is not part of the standard delivery of iris-gmbh. Connection to on-board computer/on-board unit (On-Board Computer/Unit) Figure 1: Ethernet installation in a vehicle with 2 doors 1 For, see section 1.3, page 5
7 For technical data > see page 16 For technical data > see page 18 7/24 IRMA MATRIX M12 components for Ethernet installations 2.2 scon connector for Ethernet connection scon with an open power supply connection Function: Layout: The scon connector connects the sensor to the Ethernet network. The power supply of the sensor (VP+, VP-) is effected via the open cable end. Interface / signal scon base body X Interface/signals (for drawings see data sheet: scon-s-eth-22-kq-x-y) x y 1 Interface: 1 M4 threaded hole for ground connection x = length of Ethernet cable y = length of POWER cable M12 connector (f) 4 poles, D coded Ethernet cable Sensor connection Signals: Ethernet Ethernet/ power Assignment: VP+, VP- operating voltage of sensor Connection to Signal POWER cable 2 wires and shield power Connection to wire colour and marking "..." Symbol Signal Housing Pin 1 Pin 2 Pin 3 Pin 4 Shield TD+ RD+ TD- RD- Housing and 10 contact areas to connection Shield VP- VP+ black "1" black "2" white "1" white "2" Shielding:, (for cable grade see page 5) Shield 1 2 Article designation Art. No. Brief description Cable lengths / x y (see page 5) scon-s-eth-22--1m-2m 0250_21 scon connector for Ethernet 1 m 2 m scon-s-eth-22--1m-2m 0250_24 connection with open cable for power supply 1 m 2 m For further properties of the connectors see "Technical data" on page 15 TO CONNECTION EXAMPLE, P. 6
8 For technical data > see page 20 For technical data > see page 16 8/24 IRMA MATRIX M12 components for Ethernet installations scon connector with power supply via the CAN connection Function: The scon connector connects the IRMA MATRIX sensor to the Ethernet network. The power supply of the sensor (VP+, VP-) is effected via a CAN cable with 5-pole M12 connector (m). Layout: Interface/signals scon base body Interface/signals (for drawings see data sheet: scon-s-can-eth-23- Kq-1m-1m) 1 M4 threaded hole for ground connection x = length of the CAN bus cable y = length of Ethernet cable CAN bus cable ETHERNET cable Interface: M12 connector (m) 5 poles, A coded Sensor connection Signals: CAN/power CAN/ power Assignment: Connection Connection Circuit: (for cable grade see page 5) M12 connector (f) 4 poles, D coded ETHERNET (service) Symbol to Signal 2 Signal to Symbol Pin 1 and housing Pin 2 Pin 3 Pin 4 Pin 5 Shield VP+ VP- CAN-H CAN-L Housing and 10 contact areas to connection Shield Housing TD+ RD+ TD- RD- Pin 1 Pin 2 Pin 3 Pin 4 (for cable grade see page 5) Article designation Art. No. Brief description Cable lengths / x y (see page 5) scon-s-can-eth-23--1m-1m 0250_22 scon with power supply 1 m 1 m scon-s-can-eth-23--1m-1m 0250_27 via CAN cable with 5 pole M12 connector (m, A coded) 1 m 1 m For further properties of the connectors see "Technical data" on page 15 TO CONNECTION EXAMPLE, P. 6 2 VP+, VP- sensor operating voltage
9 For technical data > see page 16 9/24 IRMA MATRIX M12 components for Ethernet installations 2.3 M12 system cable for Ethernet (CAT5) Function: M12 system cable for connecting the sensor and the switch Interface / signal Cable type Interface / signal Layout: (for drawings of the connectors see Appendix, page 24) x Cable length Interfaces/ signals: M12 male connector (4 poles, D coded)/eth ETHERNET cable M12 male connector (4 poles, D coded)/eth Assignment: Symbol Connection to Signal Connection to Signal Symbol Housing Shield Shield Housing Pin 1 Pin 2 Pin 3 Pin 4 TD+ RD+ TD- RD- TD+ RD+ TD- RD- Pin 1 Pin 2 Pin 3 Pin 4 Shielding: / Article designation Art. No. Brief description Cable length / x (see page 5) K-M12CAT5-03-1m 0215_15 1 m K-M12CAT5-03-2m 0215_18 2 m K-M12CAT5-03-5m 0215_21 5 m K-M12CAT m 0215_16 10 m K-M12CAT m 0215_22 15 m K-M12CAT m 0215_17 M12 system cable (shielded): 20 m M12 connector (m) to K-M12CAT m 0215_23 M12 connector (m) 25 m K-M12CAT m 0215_24 30 m K-M12CAT5-04-1m 0244_20 1 m K-M12CAT5-04-2m 0244_21 2 m K-M12CAT5-04-5m 0244_22 5 m K-M12CAT m 0244_23 10 m For further properties of the connectors see "Technical data" on page 15 TO CONNECTION EXAMPLE, P. 6
10 For technical data > see page 22 10/24 IRMA MATRIX M12 components for Ethernet installations 2.4 Power supply cable for switch Function: Power supply of switch Interface/signals Cable type Interface/signals Layout: (for drawings of the connectors see Appendix, page 24) x Cable length Interfaces/ signals: M12 connector (f) (4 poles, A coded)/power Switch cable Open cable end/ power Assignment: Symbol Connection to Signal 3 Signal 3 Wire color and marking "..." Pin 1 Pin 2 Pin 4 Pin 3 Housing U1 = +24 V DC U1 = 0 V DC U2 + U2 - Shield U1 = +24 V DC U2 = 0 V DC U2 + U2 - Housing brown white black blue Shield white "1" white "4" white "3" white "2" Shield Shielding: / (for cable grade see page 5) Shield brown/"1 " white/"4" black/"3" blue/"2" Article designation Art. No. Brief description Cable lengths / x (see page 5) K-Switch-Power 0215_05 Power supply cable for switch: 3 m M12 connector (f, 4 poles, A coded) SAC-4P-5,0-28R/FS SCO Rail 0244_17 with open cable end (4 wires and shield connection) 5 m For further properties of the connectors see "Technical data" on page 15 TO CONNECTION EXAMPLE, P. 6 The cables K-Switch-Power and SAC-4P-5,0-28R/FSSCO Rail are used for the power supply of econ switches made by Harting only. If other switches are installed, the assignment must be checked. The cable cannot be used for the power supply of the scon-connector with power supply via the CAN connection (different coding). 3 U1 operating power for switch, U2 can be used for redundant operating power for switch
11 11/24 IRMA MATRIX M12 components for Ethernet installations 2.5 M1-RJ45 adapter cable for connecting a laptop Function: Adapter for the connection of the sensor to a notebook for servicing. The M12 connector (m, 4 poles) is connected e. g. to a port of the switch (see FIGURE 1 (6) Page 6). The connection to the service notebook for configuration, function test and firmware updates of the sensor is effected via the RJ45 connector (m). Interface/signals Cable type Interface/signals Layout: (for drawings of the connectors see Appendix, page 24) x Cable length Interfaces/ signals: M12 connector (m) (4 poles, D coded)/ethernet Network cable RJ45 connector (m) (8 poles)/ethernet Assignment: Symbol Connection to Signal Connection to Signal Symbol Housing Shield Shield Housing Pin 1 Pin 2 Pin 3 Pin 4 TD+ RD+ TD- RD- TD+ RD+ TD- RD- Pin 1 Pin 3 Pin 2 Pin 6 Circuit: Article designation Art. No. Brief description Cable length x KQ-M12CAT5-RJ m 0244_31 KQ-M12CAT5-RJ m 0244_33 M12 RJ45 adapter for servicing: M12 connector (m, 4 poles, D coded) to RJ45 connector (m) 2 m 10 m For further properties of the connectors see "Technical data" on page 15 TO CONNECTION EXAMPLE, P. 6
12 12/24 IRMA MATRIX M12 components for Ethernet installations 3 Identification 3.1 Example of cable marking by printed inscription Identification ******* 30 mm (± 10 mm) K-M12CAT5-03-x * 0215_XX * 140NNNNN st place: Article designation 3 rd place: Manufacturer's identification 2 nd place: IRIS article No. 4 th place: Manufacturer's article number The marking is printed in black Figure2: Example of cable marking by printed inscription
13 13/24 IRMA MATRIX M12 components for Ethernet installations 3.2 Marking of cable with label (heat-shrinkable sleeve) Label with data 30 mm (± 10 mm) Label or heat-shrinkable sleeve for marking Marking of label or heatshrinkable sleeve K-M12CAT m 0215_16 H+S 02/11 iris article designation iris article No. Cable manufacturer/article No. Date of manufacture Fig. 3: Example of cable marking with a label or heat-shrinkable sleeve
14 14/24 IRMA MATRIX M12 components for Ethernet installations 3.3 Example of marking on the package Manufacturer data: Logo, address,... Batch number Manufacturing date iris-gmbh information: Article No. (Iris Part No.) and bar code Article designation Country of manufacture Recycling information Fig. 4: Example of a label on the package
15 15/24 IRMA MATRIX M12 components for Ethernet installations 4 Technical data/properties All materials used conform to the RoHS directive! All cables and connectors are shielded. 4.1 Connector 4 Properties Standards M12 connector (m)/ M12 connector (f) scon connector for sensors Mating cycles: approx. 100 approx. 75 Temperature range: (storage) -40 to +90 C -40 to 194 F -40 to +90 C -40 to 194 F Temperature range (operation): -25 to +90 C -13 to 194 F Contact layout: Housing material and material of knurled screw: 5 poles, A coded 4 poles, A coded 4 poles, D coded Metal Metal Material of handle body TPU -- flame resistant, self-extinguishing Circuit: shielded shielded Protection class acc. to IEC (in mounted condition): IP65/IP67 IP65/IP67 4 Excerpt from the manufacturers' data sheets
16 16/24 IRMA MATRIX M12 components for Ethernet installations 4.2 Cable properties Ethernet cable 5 Property Temperature range: Ethernet cable -40 to +80 C/-40 to +176 F Bending radius: 6 Voltage sustaining capability: -40 to +90 C/-40 to 194 F min. 70 mm min. 40 mm 2,000 V 2,000 V AC Wave impedance:, 100 ohms ±5 ohms Line resistance: max. 55 ohms/km max ohms/km Transmission properties acc. to EN (CAT.5):, EN (CAT.5) Cable outside diameter (D): Wire layout: litz wire: Core cross section: 6.7 mm Cable layout:, 4 x 1 Shielding in total:, Sheath material/color: 6.6 mm ± 0.4 mm or 7.25 mm ± 0.3 mm 7 x mm 7 x 0.25 mm 0.34 mm² (AWG22) 0.34 mm² (AWG22) Meshwork min. 80% and/or foil PUR/RAL6018 (yellow-green) RADOX EM 104 acc. to EN /black 5 Excerpt from the manufacturers' technical data 6 For, see section 1.3, page 5
17 17/24 IRMA MATRIX M12 components for Ethernet installations Property 7 cable supplier/article designation: Fire protection properties: Ethernet cable Company: HUBER+SUHNER - RADOX RAILCAT CAT5 ; 4x22AWG XM S RW; Article No.: RADOX RAILCAT CAT5 4x22AWG XM S Article No.: Halogen-free: - acc. to DIN VDE 0472 Part 815 or - - measured acc. to EN or IEC : Halogen acid gas content of 0.5% or - measured acc. to EN : ph level of 4.3; specific conductivity 10 µs/mm Cables for increased fire protection: - halogen-free like - acc. to DIN :2009, fire condition 4, indoor use For the cable with increased fire protection, the manufacturer 8, company HUBER+SUNER, warrants in addition to the fire protection properties given in section 1.3, page 5 the observance of additional national standards: BS5873, GM/RT 2130 Category EN Hazard level NF F Classification, category UNI CEI Hazard level NFPA 130 EN ; EN Hazard level (acc. to EN ) Hazard level code (acc. to EN ) Indoor cable: Ia, Ib, II Indoor cable HL1 HL3 C/F0; indoor cable: A1, A2, B LR1 - LR4 Fulfilled Cables and lines for rail vehicles with improved behaviour in the event of a fire Indoor cable HL3 The cable meets all fire protection requirements and hazard level HL3 acc. to EN :2013 by fulfilling the pertinent requirements for HL4 acc. to EN :2002 (items 8, 9) and EN :2002 item M Code M indicates particularly high resistance to low temperatures as well as high oil and fuel resistance on hazard level HL4 acc. to EN :2002. For the detailed data on the measuring values determined in each case please see the manufacturer's technical data sheets. 7 see below: Fire protection properties 8 Applies to the cable without fitted connectors
18 18/24 IRMA MATRIX M12 components for Ethernet installations Power cable 9 at scon connector Property Temperature range: 10 Power cable at scon -40 to 70 C/-40 to 158 F -40 to +120 C/-40 to 248 F Sensor operating voltage: (VP+; VP-), 24 V ( V) Bending radius: Voltage sustaining capability: Line resistance: Outside diameter (D): Wire layout of litz: Core cross section: min. 40 mm min. 70 mm 4,000 V 3,500 V max ohms/km typically 13.7 ohms/km 6.3 mm 6.4 mm ± 0.3 mm/6.5 mm ± 0.3 mm 24 x 0.2 mm 19 x 0.31 mm 0.75 mm² 1.5 mm² Cable layout:, 1 x 2 Shielding in total:, Meshwork min. 80% and/or foil Sheath material/color: halogen-free special mixture/ral 7001 RADOX EM104 acc. to EN /black 9 Excerpt from the manufacturers' technical data 10 For, see section 1.3, page 5
19 19/24 IRMA MATRIX M12 components for Ethernet installations Property 11 cable supplier/article designation: Fire protection properties: Power cable at scon connector Huber + Suhner - RADOX Tenuis/S EMC; article No.: RADOX P; article No.: Halogen-free: - acc. to DIN VDE 0472 Part 815 or - - measured acc. to EN or IEC : Halogen acid gas content of 0.5% or - measured acc. to EN : ph level of 4.3; specific conductivity 10 µs/mm Cables for increased fire protection: - halogen-free like - acc. to DIN :2009, fire condition 4, indoor use For the cable with increased fire protection, the manufacturer 12, company HUBER+SUNER, in addition to the fire protection properties given in section 1.3, page 5 warrants the observance of additional national standards: EN Hazard level NF F Classification, category NFPA 130 EN ; EN Hazard level (acc. to EN ) Hazard level code (acc. to EN ) Indoor cable HL1 HL3 C/F0; indoor cable: A1, A2, B Fulfilled Cables and lines for rail vehicles with improved behaviour in the event of a fire Indoor cable HL3 The cable meets all fire protection requirements and hazard level HL3 acc. to EN :2013 by fulfilling the pertinent requirements for HL4 acc. to EN :2002 (items 8, 9) and EN :2002 item M Code M indicates particularly high resistance to low temperatures as well as high oil and fuel resistance on hazard level HL4 acc. to EN :2002. For the detailed data on the measuring values determined in each case please see the manufacturer's technical data sheets. 11 For, see section 1.3, page 5 12 Applies to the cable without fitted connectors
20 20/24 IRMA MATRIX M12 components for Ethernet installations CAN cable at scon connector 13 Property Temperature range: 14 CAN cable at scon connector -40 to +80 C/-40 to +176 F -40 to +90 C/-40 to 194 F Sensor operating power: (VP+; VP-), : 24 V ( V) Bending radius: Voltage sustaining capability: Wave impedance: Line resistance: Cable outside diameter (D): Wire layout: Litz wire Core cross section: Cable layout: Shielding in total:, Sheath material/color: min. 70 mm min. 40 mm 2,000 V 2,000 V AC 120 ohms ±12 ohms 100 ohms ±5 ohms max. 78 ohms/km max ohms/km 6.7 mm 6.6 mm ± 0.4 mm or 7.25 mm ± 0.3 mm 19 x 0.13 mm/19 x 0.15 mm 7 x 0.25 mm 0.25 mm² (AWG24) and 0.34 mm² (AWG22) 0.34 mm² (AWG22) 2 x 2 4 x 1 Meshwork min. 80% and/or foil PUR/violet RAL 4001 RADOX EM104 acc. to EN /black 13 Excerpt from the manufacturers' technical data 14 For, see section 1.3, page 5
21 21/24 IRMA MATRIX M12 components for Ethernet installations Property 15 cable supplier/article designation: Fire protection properties: CAN cable at scon connector Company: HUBER+SUHNER - RADOX RAILCAT CAT5 ; 4x22AWG XM S RW; Article No.: RADOX RAILCAT CAT5 4x22AWG XM S Article No.: Halogen-free: - acc. to DIN VDE 0472 Part 815 or - - measured acc. to EN or IEC : Halogen acid gas content of 0.5% or - measured acc. to EN : ph level of 4.3; specific conductivity 10 µs/mm Cables for increased fire protection: - halogen-free like - acc. to DIN :2009, fire condition 4, indoor use For the cable with increased fire protection, the manufacturer 16, company HUBER+SUNER, in addition to the fire protection properties given in section 1.3, page 5 warrants the observance of additional national standards: BS5873, GM/RT 2130 Category EN Hazard level NF F Classification, category UNI CEI Hazard level NFPA 130 EN ; EN Hazard level (acc. to EN ) Hazard level code (acc. to EN ) Indoor cable: Ia, Ib, II Indoor cable HL1 HL3 C/F0; indoor cable: A1, A2, B LR1 - LR4 Fulfilled Cables and lines for rail vehicles with improved behaviour in the event of a fire Indoor cable HL3 The cable meets all fire protection requirements and hazard level HL3 acc. to EN :2013 by fulfilling the pertinent requirements for HL4 acc. to EN : 2002 (items 8, 9) and EN : 2002 item M Code M indicates particularly high resistance to low temperatures as well as high oil and fuel resistance on hazard level HL4 acc. to EN :2002. For the detailed data on the measuring values determined in each case please see the manufacturer's technical data sheets. 15 For, see section 1.3, page 5 16 Applies to the cable without fitted connectors
22 22/24 IRMA MATRIX M12 components for Ethernet installations Switch cable 17 Property Temperature range: 18 Switch cable -40 to 70 C/-40 to 158 F -40 to +120 C/-40 to 248 F Operating voltage: ; 24 / 48 V DC (12 60 V DC) Bending radius: Voltage sustaining capability: Line resistance: Outside diameter (D): Wire layout of litz: Core cross section: min. 59 mm min. 30 mm 3,000 V 3,500 V Cable layout:, 4 x 1 max. 58 ohms/km max ohms/km 5.9 mm ± 0.2 mm 5.4 mm ± 0.3 mm 42 x 0.1 mm 19 x 0.18 mm 0.34 mm² (AWG22) 0.5 mm² (AWG20) Shielding in total:, Meshwork min. 80% and/or foil Sheath material/color: PUR/black RADOX EM104 acc. to EN /black 17 Excerpt from the manufacturers' technical data 18 For, see section 1.3, page 5
23 23/24 IRMA MATRIX M12 components for Ethernet installations Property 19 cable supplier/article designation: Fire protection properties: Switch cable Company: HUBER+SUHNER - RADOX GKW S Halogen-free: - acc. to DIN VDE 0472 Part 815 or - - measured acc. to EN or IEC : Halogen acid gas content of 0.5% or - measured acc. to EN : ph level of 4.3; specific conductivity 10 µs/mm Cables for increased fire protection: - halogen-free like - acc. to DIN :2009, fire condition 4, indoor use For the cable with increased fire protection, the manufacturer 20, company HUBER+SUNER, in addition to the fire protection properties given in section 1.3, page 5 warrants the observance of additional national standards: BS5873, GM/RT 2130 Category EN Hazard level NF F Classification, category UNI CEI Hazard level EN ; EN Hazard level (acc. to EN ) Hazard level code (acc. to EN ) Indoor cable: Ia, Ib, II Indoor cable HL1 HL3 C/F0; indoor cable: A1, A2, B LR1 - LR4 Cables and lines for rail vehicles with improved behaviour in the event of a fire Indoor cable HL3 The cable meets all fire protection requirements and hazard level HL3 acc. to EN :2013 by fulfilling the pertinent requirements for HL4 acc. to EN : 2002 (items 8, 9) and EN : 2002 item M Code M indicates particularly high resistance to low temperatures as well as high oil and fuel resistance on hazard level HL4 acc. to EN :2002. For the detailed data on the measuring values determined in each case please see the manufacturer's technical data sheets. 19 For, see section 1.3, page 5 20 Applies to the cable without fitted connectors
24 24/24 IRMA MATRIX M12 components for Ethernet installations 5 Annex 5.1 Engineering drawings of the connectors M12 connector (m) M12 connector (f) RJ45 connector (m)
RADOX railway cables acc. to EN 50264 and EN 50306. Edition 2009
RADO railway cables acc. to EN 50264 and EN 50306 Edition 2009 Bridging our know how Interdisciplinary knowledge The HUBER+SUHNER Group is a leading international manufacturer of electrical and optical
More informationBETAtrans. Cables and Systems for Rolling Stock. Edition 2006
BETAtrans Cables and Systems for Rolling Stock. Edition 2006 Info Consulting and Sales By Phone To ask for Information or to place an order please use the following number: +49 (0)9172-6844-11 By Fax For
More information108-93018 05 APR 2016 Rev M
Product Specification 108-93018 05 APR 2016 Rev M Copper LAN Cable 1. SCOPE 1.1. Content This specification describes the general requirements for CommScope copper LAN cable. 2. APPLICABLE DOCUMENTS The
More informationPROFIBUS cable. for PROFIBUS-PA and -DP 10/63-6.46 EN
for PROFIBUS-PA and -DP 10/63-6.46 EN CPN 080/CPE 080-Ex PROFIBUS-PA basis cable AWG 18, 0.88 mm 2 Use For fixed installation indoor and outdoor, on racks and in conduits. Application Fieldbus cable for
More informationwith coloured cores and overall copper screen UL/CSA... 17
CONTENT Cable Track Cables y SD 200 extremely flexible TPE/PUR data cable with coloured cores for continuous movement..... 6 y S 200 extremely flexible TPE/PUR control cable with numbered cores for continuous
More informationThe Quality Connection. BETAflam Fire Resistant Safety Cables
The Quality Connection BETAflam Fire Resistant Safety Cables 2 Contact Consulting and sales Switzerland Phone +41 (0)62 288 82 82 Fax +41 (0)62 288 83 83 sales@leoni-studer.ch www.leoni-infrastructure-datacom.com
More informationGlobal cable expertise for rolling stock
Global cable expertise for rolling stock Global cable expertise for rolling stock Single and multicore Low voltage control cables Jumper cables HV roof cables (25 kv) rubber cables for power needs of locomotives
More informationCABLE SPECIFICATION CAN CAB RJ45-SUBD9
CABLE SPECIFICATION All technical information contained in this document is the exclusive property of STI and may neither be used nor disclosed without its prior written consent. AAV 33801 1/8 Connector
More informationBNI EIP-950-000-Z009 IP67 Module, Unmanaged Switch
BNI EIP-950-000-Z009 IP67 Module, Unmanaged Switch Balluff Ethernet IP, BNI EIP-104-100-Z016 1 Notes to the User 1.1 About this guide 2 1.2 Structure of the guide 2 1.3 Typgraphical Conventions 2 1.4 Symbols
More informationBRÖCKSKES D-VIERSEN PV1-F 4,0 mm BRÖCKSKES D-VIERSEN PV1-F 4,0 mm d d 2 2 C VDE-REG.-Nr. 8292 10/2009
d BRÖCKSKES BRÖCKSKES D-VIERSEN D-VIERSEN PV1-F PV1-F 4,0 mm 4,0 2 mm VDE-REG.-Nr. 2 C 8292 10/2009 s - THE COMPANY DIN EN ISO 9001 More than 60 years of experience in temperature measurement and control
More informationHSP GmbH Zum Handwerkerhof 2 90530 Wendelstein Tel. 09129 / 2852-0 Fax: 09129 / 2852-11 Web: www.hsshsp.de EMAIL: HSP@hsshsp.de NTG-3000.
NTG-3000 Transducer Data Sheet Document Version 2.8 Page 1 of 10 Versions / Revisions: Document Creation Author Description version date 2.0 2012-07-25 P. Compensis First official version 2.1 2012-08-24
More informationCable Plug acc. to DIN EN 175301-803, Form A
Cable Plug acc. to DIN EN 175301-803, Form A Complete program Contact form 18 mm Also available with LED indicator Optional 4-pin version for pressure switch or impulse valves respectively Versions with
More informationDSD 70 Dual Channel Hall Effect Speed Sensor for Railway Applications, compliant with EN 50155
DSD 70 Dual Channel Hall Effect Speed Sensor for Railway Applications, compliant with EN 50155 Technical information Version: 07.14 General Function The speed sensors family DSD.70 are suitable for generating
More informationHARTING econ 3000 Introduction and features
HARTING Introduction and features HARTING es, unmanaged, for installation in control cabinets General Description Features The Fast es of the product family HARTING are suitable for industrial applications
More informationSeries 8146/5-V37 and Series 8150/5-V37
www.stahl.de > Clear assignment safe technology easy installation > Intelligent structure only one rotary actuator for frequency-controlled drives ) 20 ms leading auxiliary contact for safe motor disconnection
More informationHARTING Ethernet Cabling 8-poles Overview
Ethernet Cabling 8-poles Overview RJ45 Connectors [on page 8] System cables [on page 12] Distribution modules and Outlets [on page 17] Connectors [on page 20] System cables [on page 26] Panel feed-throughs
More informationHMI display Installation Guide
HMI display Installation Guide Product Description Specifications Important Information o Package Contents o Related Documents o Accessories Cautions and Warnings Mounting and Dimensions o BAC-DIS-ENC
More informationDEK-REL- 24/1/SEN. Extract from the online catalog. Order No.: 2964050
Extract from the online catalog DEK-REL- 24/1/SEN Order No.: 2964050 Relay terminal block for sensor, with soldered-in miniature relays, contact (AgNi+Au): small to medium loads, 1 N/O contact, input voltage
More informationInductive sensor NI10-M18-Y1X-H1141
ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Threaded barrel, M18 x 1 Chrome-plated brass DC 2-wire, nom. 8.2 VDC Output acc. to DIN EN 60947-5-6 (NA- MUR) M12
More informationSquare D Clipsal DIN-Rail Four-Channel Auxiliary Input Unit
Square D Clipsal DIN-Rail Four-Channel Auxiliary Input Unit SLCLE5504AUX for Use with Wired C-Bus Networks Instruction Bulletin Retain for future use. Square D Clipsal DIN-Rail Four-Channel Auxiliary Input
More informationMagnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...
Magnetic and Hydraulic-Magnetic Circuit Breaker 840-G2... Description Single, two and three pole magnetic circuit breakers with trip-free mechanism and push/pull on/off manual actuation. A choice of fast
More informationFestoon 715 P PUR cable for flexible application in festoon systems
CABLES FOR CRANE AND CONVEYOR APPLICATIONS Festoon 715 P PUR cable for flexible application in festoon systems S AB BRÖCKSKES D-VIERSEN Festoon 715 P 1 x 16.0 mm 2 C Marking for Festoon 715 P 07150162:
More informationHARTING Ethernet Cabling 4-poles Overview
Overview RJ45 Connectors [on page 8] System cables [on page 10] Distribution modules and Outlets [on page 20] HARTING PushPull Connectors [on page 22] System cables [on page 24] Panel feed-throughs [on
More informationPROFIBUS cable. PROFIBUS DP cables Non-Ex (Hazardous) applications Ex (Hazardous) applications
Data Sheet 10/63-6.47-EN Rev. D PROFIBUS cable PROFIBUS DP cables Non-Ex (Hazardous) applications Ex (Hazardous) applications PROFIBUS PA cables Non-Ex (Hazardous) applications Ex (Hazardous) applications
More informationHARAX circular connector
Show navigation HARAX circular connector Technical characteristics Specifications IEC 60 352-4 IEC 60 9475-2 Approvals HARAX M8-S/M12-S Rated voltage Rated current Diameter of individual strands Conductor
More informationFerrostat Speed Sensor Series DSF Explosion Proof Versions EEx
Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx DSF..10.**.HV Ex ATEX Operating Instructions 374E-64368 Valid from lot nr. 0103 General Function Use in potentially explosive environment
More informationAXIS T81B22 DC 30W Midspan
INSTALLATION GUIDE AXIS T81B22 DC 30W Midspan ENGLISH About this Document This document includes instructions for installing AXIS T81B22 on your network. Previous experience of networking will be beneficial
More informationR4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT ... ... Spur 2. Spur 1. Zone 1. Zone 0
FieldBarrier Features Assembly 8... 12 outputs Ex ia IIC, FISCO and Entity Advanced fault isolation and diagnostics at the spur FieldBarrier in Zone 1/Div. 2 Instruments in Zone 0...1/Div. 1 For FOUNDATION
More informationTechnical Data Sheet OPUS A3 STANDARD Full TDS OPUS A3sF, 03.09.2012
Technical Data Sheet OPUS A3 STANDARD Full TDS OPUS A3sF, 03.09.2012 OPUS A3 Standard Full Landscape OPUS A3 Standard Full Neutral 1 Order Numbers OPUS A3 STANDARD Full Wachendorff Projektor Landscape
More informationDigital input modules
8 172 TX-I/O Digital input modules TXM1.8D TXM1.16D Two fully compatible versions: TXM1.8D: 8 inputs, each with a three-color LED (green, yellow or red) TXM1.16D: As TXM1.8X, but 16 inputs, each with a
More informationProgrammable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2
Type code Ident no. 1545065 Number of channels 2 Dimensions (W x L x H) 108 x 145 x 77.5 mm CoDeSys-programmable acc. to IEC 61131-3 Cable max. 50 m between interface and read/write head 10/100 Mbps Male
More informationDATA SHEET SERVO LK SMS FX8PLUS SIGNAL
Application LAPP servo cables according to Siemens * (see footnote) Standard FX8008 PLUS SIGNAL are a new generation of very highly flexible screened signal (encoder and resolver)- cables (P/Ns 00277101
More informationconnecdim Gateway G1 Ethernet TCP/IP to DALI
Gateway G1 Ethernet TCP/IP to LI Independent lighting control for up to 256 LI gears on 4 LI lines Can be expanded by connecting multiple gateways on the same network Cloud based web interface for configuration
More informationICON Server box installation manual Rev. 1.1
ICON Server box installation manual Rev. 1.1 Contents 1.0 About this manual... 3 2.0 Intended use... 3 2.1 European WEEE directive... 3 3.0 Installation and service instructions... 4 Server box overview...
More informationIntesisBox KNX Mitsubishi Heavy Industries AC
IntesisBox KNX Mitsubishi Heavy Industries AC Gateway for integration of Mitsubishi Heavy Indsutries (MHI) Air Conditioners with KNX control systems. 1. Main Features Direct connection to KNX TP-1 (EIB)
More informationSupplementary instructions. Connection cable IP 66/IP 68 (1 bar) Retrofitting set/accessory for instruments of the plics family. Document ID: 34107
Supplementary instructions Connection cable IP 66/IP 68 (1 bar) Retrofitting set/accessory for instruments of the plics family Document ID: 4107 Contents Contents 1 For your safety 1.1 Appropriate use...
More information01. HARTING RJ INDUSTRIAL RJ45 ETHERNET CONNECTORS
. HARTING RJ INDUSTRIAL ETHERNET CONNECTORS Ethernet is is coming up to standard industrial interface. Therefore, automation devices such as controllers, sensors and actuators feature possess on one or
More informationFlexible and safe solutions, for decades. Cables for alarmand safety systems
Flexible and safe solutions, for decades. Cables for alarmand safety systems 2 We offer the widest range of cables on the market for every kind of installation. It s all about reliability. It is always
More informationETHERLINE Ethernet Cable, Connectors & Tools
Ethernet Cable, ors & Tools 2 Pair 242 4 Pair 249 Industrial Ethernet ors & Tools 256 Ethernet Cable, ors & Tools ETHERNET CABLE, CONNECTORS & TOOLS Quick Select Chart 240 2 Pair 2 Pair: CAT.5/5e; Stationary
More informationHARTING Ethernet Cabling 4-poles Overview
Ethernet Cabling 4-poles Overview RJ45 Connectors [on page 8] System cables [on page 10] Distribution modules and Outlets [on page 20] Connectors [on page 22] System cables [on page 24] Panel feed-throughs
More informationmaxon motor maxon motor control EPOS Positioning Controller Cable Starting Set Edition June 2006 part number 302287 Positioning Controller
control EPOS Positioning Controller Cable Starting Set Edition June 2006 24/1 part number 302287 Positioning Controller Documentation Cable Starting Set 1 Table of contents 1 Table of contents... 2 2 Table
More informationRISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER
Application : The RISH CON - Hz transducer is used for frequency measurement. The output signal is proportional to measured frequency and is either load independent DC Current or load independent DC Voltage.
More informationPressure transmitter For general industrial applications Model A-10
Electronic pressure measurement Pressure transmitter For general industrial applications Model A-10 WIKA data sheet PE 81.60 for further approvals see page 9 Applications Machine building Shipbuilding
More informationMultiViu Flex 7 Data Sheet
Division Interior MultiViu Flex 7 Data Sheet Picture: MultiViu Flex 7 Picture: MultiViu Flex 7 Description CAN-capable multifunction Solution Features: Robust and versatile design CAN-capability (SAE J1939,
More informationModular I/O System Analog and Digital Interface Modules
OPERATING INSTRUCTIONS Modular I/O System Analog and Digital Interface Modules Installation Operation Maintenance Document Information Document ID Title: Operating Instructions Modular I/O System Part
More informationSealed Industrial Ethernet Circular IP67 Cat. 5e RJ45 Connector System
Revised Sept--22-2009 Sealed Industrial Ethernet Circular IP67 Cat. 5e RJ45 Connector System Description The sealed circular RJ45 connector system is designed for use in harsh environments. The connector
More informationHARTING mcon 1000 Introduction and features
Introduction and features HARTING mcon 1000 es, managed, for mounting onto top-hat mounting rail in control cabinets General Description Features Supporting Ethernet (10 Mbit/s), Fast Ethernet (100 Mbit/s)
More information08. SEK IDC CONNECTORS
. IDC CONNECTORS connectors for flat cables enable simple and, cost-optimized device configuration. connectors are preferably used for connection within the device. HARTING offers a broad range of these
More informationOptions for ABB drives, converters and inverters. User s manual FDPI-02 diagnostics and panel interface
Options for ABB drives, converters and inverters User s manual FDPI-02 diagnostics and panel interface Table of contents Table of contents 3 1. FDPI-02 diagnostics and panel interface Safety..............................................
More informationProcess modules Digital input PMI for 24 V DC inputs for 120 V AC inputs
E031026 000823 Process modules Digital input PMI for inputs for 120 V AC inputs PMI Input E4, E5, GND L- PMI 120 V AC Input E4, E5, Common C E6, E7, GND L- E6, E7, Common C LEDs for the inputs operation
More information7000 Series Buccaneer
The all plastic and metal construction of the - circular that combine the ease of use of a quick coupling mechanism with proven environmental sealing for signal and mains power. Designed and independently
More informationFN2001-A1 Network module (SAFEDLINK) Mounting Installation
FN00-A Network module (SAFEDLINK) Mounting Installation A6V050_f_en_-- 05-0-6 Building Technologies Division Legal notice Legal notice Technical specifications and availability subject to change without
More informationFlexible Control Cables
Works photo: KUKA Flexible Control Cables A Flexible Control Cables Since generations people try to build machines and plants which shall take on different functions. To raise, sink, slide, drill, transport
More informationCOAX Cables Radio Frequency Cables
COAX Cables Radio Frequency Cables Contents Page Table of contents Pictographs General information Introduction Types and abbreviations Temparature range Construction Characteristics Special constructions
More information5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual
5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual Content Overview... 1 Introduction... 1 Features... 3 Packing List... 4 Safety Precaution... 4 Hardware Description... 5 Front Panel...
More informationTechnical Data Sheet OPUS A6 STANDARD Basic TDS OPUS A6sB, 02.10.2012
Technical Data Sheet OPUS A6 STANDARD Basic TDS OPUS A6sB, 02.10.2012 OPUS A6 STANDARD Basic Landscape OPUS A6 STANDARD Basic Landscape/Portrait 1 Order Numbers OPUS A6 STANDARD Full Wachendorff Projektor
More informationEVOline Multimedia Modules
243 EVOline VGA cable EVOline DVI-A cable EVOline DVI-D cable EVOline HDMI cable Cable properties Flame retardant self extinguishing VW-1 Halogen free yes yes yes Colour Black Black Outer diameter 7,2
More informationTechnical Data. Dimensions
0102 Model Number Features Comfort series 5 mm flush Usable up to SIL 2 acc. to IEC 61508 Accessories BF 18 Mounting flange, 18 mm EXG-18 Quick mounting bracket with dead stop Technical Data specifications
More informationModel 201 Wiegand Touchpad Reader Installation Guide
Model 201 Wiegand Touchpad Reader Installation Guide P/N 460353001C 15AUG11 2011 UTC Fire & Security. All rights reserved. This document may not be copied in whole or in part or otherwise reproduced without
More information< SD 200 C TP Continuously flexible TPE/PUR paired data cable with coloured cores and overall copper screen... 10
CONTENT General < The Company..................................................................................... 3 Customized cables for different applications < Data / POF Cables POF-LWL and hybrid
More informationAlarm over IP. IRIS Touch Home Installation Manual. Version 1.0 ENGLISH. Now certified and compliant with EN50131, EN50136 Security Grade 4 ATS6
Alarm over IP IRIS Touch Home Installation Manual Version 1.0 ENGLISH Now certified and compliant with EN50131, EN50136 Security Grade 4 ATS6 1. Introduction No more bulky batteries, just one sleek unit
More informationAnalogue Input, 4-fold, MDRC AE/S 4.1, GH Q605 0054 R0001
Analogue Input, -fold, MDRC, GH Q605 005 R0001 The analogue input is a DIN rail mounted device for insertion in the distribution board. It is connected to the EIB via the bus connecting terminal supplied.
More informationSeries 7500 Torque Sensor
Properties PTO (Power Take-Off) shaft with integrated torque and angle measurement Non-contact measurement system, high robustness Plug & Play solution, no additional electronics required Performance Measurement
More informationHOW TO CORRECTLY CONNECT DEEP CYCLE BATTERIES AND CHOOSE THE RIGHT CABLE SIZING
HOW TO CORRECTLY CONNECT DEEP CYCLE BATTERIES AND CHOOSE THE RIGHT CABLE SIZING There are several ways to wire multiple batteries to achieve the correct battery voltage or capacity for a particular DC
More informationInstallation Manual (English) Adjustable Active DP Terminator T1-Pepper Active RS485 segment termination for non-compliant cable
Installation Manual (English) Adjustable Active DP Terminator T1-Pepper Active RS485 segment termination for non-compliant cable Designed for use with the COMbricks SALT repeater All baudrates Redundant
More informationConnection technology from ifm.
Connection technology from ifm. Connection technology www.ifm.com/gb/connect WARRANTY years on ifm products The right choice for reliable connections. ecolink M. Cannot be overtightened! Due to the special
More informationTechnical Data. Dimensions
0102 Model Number Features 15 mm quasi flush Usable up to SIL2 acc. to IEC 61508 Accessories BF 30 Mounting flange, 30 mm V1-G-N-2M-PUR Female cordset, M12, 2-pin, NAMUR, PUR cable V1-W-N-2M-PUR Female
More informationAdjustment functions for both span and shift have been incorporated
SENSORS FOR SERIES LED Type Wafer Alignment Sensor FX-0-F FT-F9 FD-F7 EX-F70/F60 M SH-7 FD-L4 M-DW The use of a safe LED light beam now allows for high precision detection with a resolution of 0!m (.8
More information14 PHOENIX CONTACT Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108. info@powermation.com - 800-843-9859 - www.powermation.
14 PHOENIX CONTACT PLUSCON circular is a circular connector for use in industrial automation. The range of design sizes available is varied, starting with the design sizes M5 to M8 and M1, for sensor/actuator
More informationgesis IP + Heavy Duty Class I, Zone 2
gesis IP + Heavy Duty gesis IP+ 20i HD Z2 Heavy-Duty Connectors for Class 1, Zone 2 Hazardous Locations Catalog 2012 Catch the Next Wave in Modular Connections Plug & Go Heavy-Duty Connectors for areas
More informationFLEXIBLE INDUSTRIAL CABLES H07RN-F TENAFLEX SR
FLEXIBLE INDUSTRIAL CABLES H07RN-F TENAFLEX SR Standards : CENELEC HD 22.4 NF C 32-102-4 DIN VDE 0282-1 and VDE 0282-4 BS 6007 and BS 6500 IEC 60245-4 Rated voltage Rated voltage: 450/750 V (Use up to
More information3/2- and 2/2-way cartridge valve type BVE
3/2- and 2/2-way cartridge valve type BVE for any flow direction, zero leakage, all ports pressure resistant Flow Q max = 70 lpm Perm. pressure p max = 400 bar Additional valves with same function: ' Type
More informationMitel DECT Base Stations
Mitel DECT Base Stations On-site Mobility for Professionals The Mitel BS300 range of base stations offers a variety of coverage patterns to suit different situations. By choosing the right mix of base
More informationPCS0100en 02.2008. Persy Control Services B.V. Netherlands
P-Bus Gateway PBGW2.128 Universal gateway between the P-bus protocol and open standard protocols. The variety of available electrical interfaces on the gateway offers a wide range of possibilities for
More informationHARTING mcon 3000 Introduction and features
Introduction and features HARTING mcon 3000 es, managed, for mounting onto top-hat mounting rail in control cabinets General Description Features The fully managed es of the product family HARTING mcon
More informationProduct Information. Gateway For Connecting EnDat Encoders to PROFIBUS-DP
Product Information Gateway For Connecting EnDat Encoders to PROFIBUS-DP April 2012 PROFIBUS Gateway For Connecting EnDat Encoders Encoders with EnDat interface for connection via gateway All absolute
More informationENERGY. TECSUN DUO (PV) Twin Cables for Photovoltaics
ENERGY TECSUN DUO (PV) Twin Cables for Photovoltaics Auswahlkriterien Manufacturer Trademark Approvals Application Prysmian Kabel und Systeme GmbH Kabel- und Leitungswerk Neustadt bei Coburg / Germany
More informationDMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor
DMP Industrial Pressure Transmitter for Low Pressure Stainless Steel Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 / 0. % FSO from 0... 00 mbar up to 0... 40 bar Output signals
More informationPressure monitoring equipment for oil-sf 6. bushings, type GOEK
Pressure monitoring equipment for oil-sf 6 bushings, type GOEK Installation and maintenance guide 5693 827-6 en, Rev. 3, 2002-01-30 This document must not be copied without our written permission, and
More information7 Lighting Technology
7 Lighting Technology Series HS6145 For use in Zone 1 and Zone 2 Comply with requirements of Fire Department standard DIN 14 462 Battery state display Deep discharge protection Open circuit monitor Light
More informationHousing diameter Shaft diameter 1. Flange (Mounting of housing) Protection class shaft input (EN 60529) Protection class housing (EN 60529)
Direct mounting without coupling Flexible hollow shaft design up to diameter 4 mm Through hollow shaft or as end shaft (blind shaft) Easy installation by means of clamping shaft or blind shaft Short overall
More informationKNX TH65-AP. Thermo-Hygrometer. Technical specifications and installation instructions Item number 70184
EN KNX TH65-AP Thermo-Hygrometer Technical specifications and installation instructions Item number 70184 Elsner Elektronik GmbH Control and Automation Engineering Herdweg 7 D 75391 Gechingen Phone +49
More informationTECHNICAL DATASHEET Incremental Encoder RI 58-D / RI 58TD
Direct mounting without coupling Flexible hollow shaft design up to diameter 4 mm Through hollow shaft or as end shaft (blind shaft) Easy installation by means of clamping shaft or blind shaft Short overall
More informationPCAN-B10011S Bus Converter High-speed CAN to Truck Trailer CAN. User Manual. Document version 2.1.0 (2013-11-15)
PCAN-B10011S Bus Converter High-speed CAN to Truck Trailer CAN User Manual Document version 2.1.0 (2013-11-15) Products taken into account Product Name Model Part number PCAN-B10011S IPEH-002041 CANopen
More informationTX OPEN RS232/485 module
s 8 185 8185P01 TX-I/O ; DESIGO OPEN TX OPEN RS/485 module for integrating third-party systems and devices to DESIGO (V4 or higher) TXI1.OPEN Platform to integrate third-party systems and devices to the
More information4 non-safe digital I/O channels 2 IO-Link Master V1.1 slots. Figure 1. Figure 2. Type code. TBPN-L1-FDIO1-2IOL Ident no. 6814053.
PROFINET slave Integrated Ethernet switch 100 Mbps supported 2 x M12, 4-pin, D-coded, Ethernet fieldbus connection Glass-fiber reinforced housing Shock and vibration tested Potted module electronics Protection
More informationHa-VIS FTS 3000 Introduction and features
Ha-VIS Introduction and features Ethernet Switch Ha-VIS FTS 3100s-A 10-port Ethernet Switch with Fast Track Technology configurable via USB General Description Features The Fast Ethernet Switches of the
More informationMTX-D, Oil Temperature/Pressure Gauge
MTX-D, Oil Temperature/Pressure Gauge 1 Mounting and Sensor Installation... 3 1.1 Mounting the Gauge... 3 1.2 Oil Temp Sensor... 3 1.3 Oil Pressure Sensor... 3 2 Wiring... 3 2.1 Main Gauge Wiring... 4
More informationHARTING Ethernet Cabling 4-poles Overview
Overview RJ45 Connectors [on page 8] System cables [on page 10] Distribution modules and Outlets [on page 20] HARTING PushPull Connectors [on page 22] System cables [on page 24] Panel feed-throughs [on
More informationTELENOR NETT SPECIFICATION
TELENOR NETT SPECIFICATION Specification no.: A56 Edition: 1.1 Date/approval: 000919 / Jon Weberg Access to 2048 kbit/s (Structured/Unstructured) digital leased circuits. Specification of the network side
More informationCombi switchbox with integrated 3/2 way pilot valve
H Combi switchbox with integrated 3/2 way pilot valve Construction The GEMÜ combi switchbox with integrated 3/2 way pilot valve for pneumatically operated quarter turn actuators has a micro-processor controlled
More informationControl cables CF880 PVC 12,5-5/ +70 3 20 2 CF881 PVC 12,5-5/ +70 3 20 4. CF890 igupur 12,5-20/ +80 3 20 6. CF891 igupur 12,5-20/ +80 3 20 8
ables......chainflex M...11.2013...plastics for longer life....eu 1million hainflexm...cost-efficient cable program for machine tools... The new igus chainflex M cables chainflex M type Rainer Rössel Head
More informationRTEX Cable 2015/10/1. Motor Business Unit Automotive & Industrial Systems Company Panasonic Corporation
RTEX Cable 2015/10/1 Motor Business Unit Automotive & Industrial Systems Company Panasonic Corporation Cable and Connector Page 2 2015/10/1 Rev. 5 Motor Business Unit, AIS Company The Kind of Ethernet
More informationDiwiTherm, Resistance Thermometers Model TR75, with digital Display Battery or Solar Powered
Electrical Temperature Measurement DiwiTherm, Resistance Thermometers Model TR75, with digital Display Battery or Solar Powered WIKA Data Sheet TE 60.75 Applications Machinery, plant and tank construction
More informationModel CS 64 Mini-DIN Cable and Adaptor
Model CS 64 Mini-DIN Cable and Adaptor Page 1 of 9 Features Hi-Pro and NOAHlink compatible cable & Mini-DIN CS 64 Clip Module / NOAHlink Adaptor #1 Integrated Clip Module - Mini-DIN Cable Integrated NOAHlink
More informationSolenoid Valve Island Type 3965
Solenoid Valve Island Type 365 for the control of pneumatic actuators General The Type 365 Solenoid Valve Island is a compact solution for the centralized control of pneumatic actuators in chemical and
More informationGivare NC-SRS 280 och 880
Givare NC-SRS 280 och 880 Aratron AB/Nordic Control, 02 03 SRS280SEALED ROTARY SENSOR PERFORMANCE ±2 Resistance ±20% Hysteresis (repeatability) Accuracy Applied voltage maximum Resolution Output smoothness
More informationIMMS-CCC. IMMS-CCC Hardwire Central Interface. Installation Instructions
IMMS-CCC IMMS-CCC Hardwire Central Interface Installation Instructions TABLE OF CONTENTS... Choose a Location... 1 Connections... 2 Operations... 3 Software Configuration... 4 Troubleshooting... 5 Loopback
More informationLaser diffuse reflection light scanner with background suppression. Dimensioned drawing
Specifications and description HRTL 3B Laser diffuse reflection light scanner with background suppression Dimensioned drawing We reserve the right to make changes DS_HRTL3B_en.fm en 01-2010/12 50114049
More informationElectronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm
Electronic pressure measurement Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm WIKA data sheet PE 81.67 Applications Machine tools Hydraulics
More information