FN2001-A1 Network module (SAFEDLINK) Mounting Installation

Size: px
Start display at page:

Download "FN2001-A1 Network module (SAFEDLINK) Mounting Installation"

Transcription

1 FN00-A Network module (SAFEDLINK) Mounting Installation A6V050_f_en_ Building Technologies Division

2 Legal notice Legal notice Technical specifications and availability subject to change without notice., 05 Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model or design patent are reserved. Issued by: Building Technologies Division 8 Fernwood Road Florham Park, NJ 079 Tel Edition: Document ID: A6V050_f_en_-- A6V050_f_en_-- Building Technologies Division

3 Table of contents Network module (SAFEDLINK) FN Description.... Installation...5. Installing the shielding...6. Views Pin assignments Connector Indicators Technical data... 0 FCC Statement... A6V050_f_en_-- Building Technologies Division

4 Network module (SAFEDLINK) FN00 Description Network module (SAFEDLINK) FN00. Description The network module FN00 (SAFEDLINK) is used to network several via the system bus FCnet/C-WEB. FN00 may only be used for networking in a fire detection system. The network module is plugged onto the PMI & mainboard and has the following features: Connections for a system bus input and a system bus output Integrated degraded mode function with signal transfer in the event of line trouble Electrical isolation between the system bus and the panel Ground fault supervision Signal transfer in the event of line trouble caused by redundant networking with one network module per panel A6V050_f_en_-- Building Technologies Division

5 Network module (SAFEDLINK) FN00 Installation. Installation The network module (SAFEDLINK) FN00 must be installed in the left slot () (main module slot). 5 Installing the network module (SAFEDLINK) FN00 Fastening tabs on operating unit Nut for screwed cable gland ( per module) Cable gland ( per module) x fixing screw 5 Network module (SAFEDLINK) on (master module) FCnet/SAFEDLINK or C-WEB/SAFEDLINK connection terminal Connection terminal on PMI & mainboard When using shielded cables, the cable glands are needed to secure the shielding. Make sure you install the network module (SAFEDLINK) in the correct position (plug ) during installation. 5 A6V050_f_en_-- Building Technologies Division

6 Network module (SAFEDLINK) FN00 Installing the shielding. When shielded cables are used, mount the two cable glands () with the nuts () on the flange between the fastening tabs ().. Plug the network module (SAFEDLINK) (5) into the connector as shown.. Fasten the network module to the fastening tabs () using the two fixing screws ().. Check that the network module is secured correctly in order to prevent open circuits. 5. Wire up the system bus SAFEDLINK according to the pin assignment.. Installing the shielding If using shielded cables, the cable gland must be fitted. Installing the shielding Nut Sealing element Contact sleeve Bottom part of cable gland 5 Braid X Length of contact sleeve. Pull nut (), sealing element () and contact sleeve () over cable.. Trim outer cable surround to the desired length.. Trim braid or shield film to the contact sleeve (X) length.. Slide nut (), sealing element () and contact sleeve () to end of surround. 5. Place braid or shield film over contact sleeve (). Cut off protruding material. 6. Guide the prepared cable into fitted bottom part of cable gland () until sealing element () and contact sleeve () are flush in bottom part. 7. Screw nut () to bottom part such that the cable is firmly pressed in. 6 A6V050_f_en_-- Building Technologies Division

7 Network module (SAFEDLINK) FN00 Views. Views X H H RUN H Network module (SAFEDLINK) FN00 X X Connector to the PMI & mainboard (connector on rear panel) X Connector to the FCnet/C-WEB circuits (connector on rear); not used with FS0/FS90 Connector to FCnet/C-WEB circuits; used with FS0/FS90 H LED green: Status display for network module H LED yellow: Status display for circuit H LED yellow: Status display for circuit.5 Pin assignments.5. Connector Pin Designation Description A Circuit (+) B Circuit ( ) A Circuit (+) B Circuit ( ) Admissible cable cross-section: AWG 7 A6V050_f_en_-- Building Technologies Division

8 Network module (SAFEDLINK) FN00 Pin assignments Wiring for class A network Class A SAFEDLINK wiring Pair Pair Pair n Pair n ABAB ABAB AB AB ABAB FN00 First SAFEDLINK module FN00 FN00 FN00 Intermediate SAFEDLINK modules Last SAFEDLINK module Wiring for class B network Class B SAFEDLINK wiring Pair Pair Pair n ABAB AB AB ABAB ABAB FN00 First SAFEDLINK module Ground fault detected at < kω FN00 FN00 FN00 Intermediate SAFEDLINK modules Power limited acc. to NFPA 70 / NEC 760 No EOLR required Connect shields at one end only Max. length of SAFEDLINK wiring between two modules: 00 ft / 005 m or 0 db loss at 00 khz 00 ft / 005 m or 0 db loss at MHz All wiring is supervised for open circuits and short-circuits. Last SAFEDLINK module You will find detailed instructions on configuring the class A and class B SAFEDLINK network in the following documents: A6V050 for Desigo A6V0 for Cerberus PRO 8 A6V050_f_en_-- Building Technologies Division

9 Network module (SAFEDLINK) FN00 Indicators.6 Indicators LED Color Function Condition Meaning RUN (H) Green Condition of the network module (SAFEDLINK) (H) Yellow Status of circuit (A, B) (H) Yellow Status of circuit (A, B) Off On Flashes Off Network module (SAFEDLINK) is defective Normal condition (H and H are off) Normal condition for degraded mode module (H and H are off) Normal condition (communication on circuit is OK) On Error on circuit (no communication on circuit ) Off Normal condition (communication on circuit is OK) On Error on circuit (no communication on circuit ) 9 A6V050_f_en_-- Building Technologies Division

10 Network module (SAFEDLINK) FN00 Technical data.7 Technical data Supply Voltage DC V Current System bus SAFEDLINK Voltage DC 5 V Impedance Cable type: Shielded Line-to-line capacitance Line-to-shield capacitance Cable type: Unshielded Line-to-line capacitance Protocol Data rate in operation mode: 'Standard': 'Low': Distance between two network modules Electrical isolation between FCnet/C-WEB and panel Supervised for: Standby 5 ma Alarm 5 ma 0 Ω 50 loop resistance 0 Ω 0 loop resistance 80 Ω 50 loop resistance 0 Ω 0 loop resistance 80 Ω 0 loop resistance 0 Ω 60 loop resistance 80 Ω SAFEDNET (UDP/IP) kbit/s 96 kbit/s Max. 00 ft / 005 m kv Short circuit Open circuit Ground fault Communication error Connections Wire gauge AWG Operating unit Plug-type connection 0 A6V050_f_en_-- Building Technologies Division

11 FCC Statement FCC Statement WARNING Installation and usage of equipment is not in accordance with instructions manual Radiation of radio frequency energy Interference to radio communications Install and use equipment in accordance with instructions manual. Read the following information. This equipment generates, uses, and can radiate radio frequency energy and if not installed and used in accordance with the instructions manual, may cause interference to radio communications. It has been tested and found to comply with the limits for a Class A computing device pursuant to Part 5 of FCC Rules, which are designed to provide reasonable protection against such interference when operated in a commercial environment. Operation of this equipment in a residential area is likely to cause interference in which case the user at his own expense will be required to take whatever measures may be required to correct the interference. A6V050_f_en_-- Building Technologies Division

12 Issued by Building Technologies Division 8 Fernwood Road Florham Park, NJ 079 Tel Technical specifications and availability subject to change without notice. Document ID A6V050_f_en_-- SAP order no.: A5Q FS0/FS90 Edition

FCA2031-A1 Connection module (MoNet) Mounting Installation

FCA2031-A1 Connection module (MoNet) Mounting Installation FCA2031-A1 Connection module (MoNet) Mounting Installation 2014-04-29 Building Technologies Division Legal notice Legal notice Technical specifications and availability subject to change without notice.

More information

FN2006-U1, FN2007-U1 Fiber network module (SM), Fiber network module (MM) Mounting Installation

FN2006-U1, FN2007-U1 Fiber network module (SM), Fiber network module (MM) Mounting Installation FN2006-U, FN2007-U Fiber network module (SM), Fiber network module (MM) Mounting Installation 6V05048_c_en_-- 204-06-2 Building Technologies Division Legal notice Legal notice Technical specifications

More information

Input module, input/output module

Input module, input/output module Sinteso / Cerberus PRO Input module, input/output module FDCI221, FDCIO221 Input module and input/output module for the automatically addressed detector line Input module FDCI221: Monitorable contact input

More information

ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01

ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01 ABB Drives User s Manual Pulse Encoder Interface Module RTAC-0 Pulse Encoder Interface Module RTAC-0 User s Manual 3AFE 64486853 REV A EN EFFECTIVE:.5.00 00 ABB Oy. All Rights Reserved. Safety instructions

More information

10/100/1000BaseT to Mini-GBIC Industrial Media Converter

10/100/1000BaseT to Mini-GBIC Industrial Media Converter 10/100/1000BaseT to Mini-GBIC Industrial Media Converter User Manual Content Overview... 1 Introduction... 1 Features... 3 Packing List... 4 Safety Precaution... 4 Hardware Description... 5 Front Panel...

More information

Detector transparent with Color Inserts. FAA 500 TR P Trim Ring transparent with Color Inserts. FCA 500 / FCA 500 E Detector Bases

Detector transparent with Color Inserts. FAA 500 TR P Trim Ring transparent with Color Inserts. FCA 500 / FCA 500 E Detector Bases Detector Color Detector transparent with Color Inserts FAA 500 TR W Trim Ring FAA 500 TR P Trim Ring transparent with Color Inserts FAA 500 BB Ceiling Mount Back Box FCA 500 / FCA 500 E Detector Bases

More information

Installation Instructions

Installation Instructions Installation Instructions This document provides you with the following information: Because of the variety of uses for the products described in this publication, those responsible for the application

More information

BroadBand PowerShield. User Manual

BroadBand PowerShield. User Manual BroadBand PowerShield User Manual 990-0375G 12/2006 Chapter 1 General Information The PowerShield provides a power source for broadband telephony and other DC applications. Safety This Safety Guide contains

More information

Keypad D222. Installation Instructions. 1.0 Description. 1.3 Response Tones. 1.1 Display. 1.2 Keys

Keypad D222. Installation Instructions. 1.0 Description. 1.3 Response Tones. 1.1 Display. 1.2 Keys Keypad D222 Installation Instructions 1.0 Description The D222 Keypad (Figure 1) is a low-profile, surface-mount, three-wire unit with four hard-wired expansion points for use with Bosch Security Systems

More information

MAXCOM GOLD SERIES Owners Installation Guide

MAXCOM GOLD SERIES Owners Installation Guide MAXCOM GOLD SERIES Owners Installation Guide Document Number - HMMI-001-01-00 Honeywell 2004 1 of 13 HMMI-001-01-00 Owners Installation Guide TELEMETRY CONTROL SYSTEM TABLE OF CONTENTS 1.0 Box Contents...

More information

MCR1900 Media Converter 19-Slot Chassis

MCR1900 Media Converter 19-Slot Chassis MCR1900 Media Converter 19-Slot Chassis Installation Guide Part #5500304-11 Copyright Statement This document must not be reproduced in any way whatsoever, either printed or electronically, without the

More information

DBS720 / FDS221-R / FDS221-W Sounder base, Alarm sounders

DBS720 / FDS221-R / FDS221-W Sounder base, Alarm sounders DBS720 / FDS221-R / FDS221-W Sounder base, Alarm sounders For the automatic addressable detector bus C-NET Cerberus PRO Sounder base DBS720 11 selectable tones, 2 programmable activation levels Sound intensity

More information

1788HP-EN2PA-R FAULT CHECKS

1788HP-EN2PA-R FAULT CHECKS 1788HP-EN2PA-R FAULT CHECKS V1.00.01 Section 1788HP-EN2PA-R OFFLINE FIELD DEVICE NOT DETECTED FIELD DEVICE IS NOT CONFIGURED FIELD DEVICE FAULTS Page 2 4 8 9 1 1788HP-EN2PA-R OFFLINE SYMPTOM I/O Tree in

More information

Data sheet GIOD.1 Input/output module with CAN bus. ERP no.: 5204183. www.guentner.de. Data sheet GIOD.1 V_3.0

Data sheet GIOD.1 Input/output module with CAN bus. ERP no.: 5204183. www.guentner.de. Data sheet GIOD.1 V_3.0 Data sheet GIOD.1 Input/output module with CAN bus ERP no.: 5204183 www.guentner.de Page 2 / 10 Contents 1 GIOD.1... 3 1.1 Functional description...3 1.2 Connections... 5 1.3 Electrical properties of...

More information

LevelOne IFE-0500 4-Port PoE + 1-Port TP Industrial Fast Ethernet Switch User Manual

LevelOne IFE-0500 4-Port PoE + 1-Port TP Industrial Fast Ethernet Switch User Manual LevelOne IFE-0500 4-Port PoE + 1-Port TP Industrial Fast Ethernet Switch User Manual Ver. 1.0.0-0711 1 FCC Warning This Equipment has been tested and found to comply with the limits for a Class-A digital

More information

SDV1092-8 Music Mixer / Equaliser Installation guide and user manual

SDV1092-8 Music Mixer / Equaliser Installation guide and user manual EIGHT CHANNEL MIXER/EQUALISER SDV1092-8 Music Mixer / Equaliser Installation guide and user manual 1 CONTENTS CONTENTS...2 SAFETY NOTES...3 INTRODUCTION...4 USER CONTROLS...7 VOLUME CONTROL...7 MUSIC SOURCE

More information

Modular I/O System Analog and Digital Interface Modules

Modular I/O System Analog and Digital Interface Modules OPERATING INSTRUCTIONS Modular I/O System Analog and Digital Interface Modules Installation Operation Maintenance Document Information Document ID Title: Operating Instructions Modular I/O System Part

More information

IPX AUTOMATIC IP NETWORK LOSS BACKUP A/B SWITCH INSTRUCTION BOOK IB6444-02

IPX AUTOMATIC IP NETWORK LOSS BACKUP A/B SWITCH INSTRUCTION BOOK IB6444-02 IPX AUTOMATIC IP NETWORK LOSS BACKUP A/B SWITCH INSTRUCTION BOOK IB6444-02 TABLE OF CONTENTS DESCRIPTION 2 MOUNTING INSTRUCTIONS 2 HOW TO CABLE THE IPX 2/3 POWER SUPPLY INSTALLATION 3 OPERATION 3 CARE

More information

CelluLine CGW-TS GSM Cellular Gateway. Installation and Programming Manual

CelluLine CGW-TS GSM Cellular Gateway. Installation and Programming Manual CelluLine CGW-TS GSM Cellular Gateway Installation and Programming Manual CelluLine CGW-TS GSM Cellular Gateway Installation and Programming Manual CGWTS-M001A Version 1, Release 1, December 2004 NOTICE

More information

SP4-LOC SAFEPATH4 REMOTE MICROPHONE AND LOCAL OPERATOR CONSOLE

SP4-LOC SAFEPATH4 REMOTE MICROPHONE AND LOCAL OPERATOR CONSOLE SP4LOC SAFEPATH4 REMOTE MICROPHONE AND LOCAL OPERATOR CONSOLE INSTALLATION AND OPERATION MANUAL MASS NOTIFICATION SYSTEM Part Number: P84767 Rev. A Copyright 2006 Cooper Wheelock, Inc. All rights reserved.

More information

SP1790JK 900MHz Wireless Indoor/Outdoor Speakers. User Manual INTRODUCTION FEATURES IMPORTANT SAFETY INFORMATION

SP1790JK 900MHz Wireless Indoor/Outdoor Speakers. User Manual INTRODUCTION FEATURES IMPORTANT SAFETY INFORMATION SP1790JK 900MHz Wireless Indoor/Outdoor Speakers INTRODUCTION This 900 MHz digital hybrid wireless speaker system uses the latest wireless technology that enables you to enjoy music and TV sound anywhere

More information

EVC40 EMERGENCY VOICE COMMUNICATION SYSTEM

EVC40 EMERGENCY VOICE COMMUNICATION SYSTEM EVC40 EMERGENCY VOICE COMMUNICATION SYSTEM INSTALLATION MANUAL Protec Fire Detection PLC, Protec House, Churchill Way, Nelson, Lancashire, BB9 6RT. Telephone: +44 (0) 1282 717171 Fax: +44 (0) 1282 717273

More information

USB 2.0 RG Port USB m CAT 5e/6/7 Extender System. User Guide

USB 2.0 RG Port USB m CAT 5e/6/7 Extender System. User Guide USB 2.0 RG2304 4-Port USB 2.0 100m CAT 5e/6/7 Extender System User Guide Thank you for purchasing the USB 2.0 RG2304 Extender System. Please read this guide thoroughly. This document applies to Part Numbers:

More information

Square D Clipsal DIN-Rail Four-Channel Auxiliary Input Unit

Square D Clipsal DIN-Rail Four-Channel Auxiliary Input Unit Square D Clipsal DIN-Rail Four-Channel Auxiliary Input Unit SLCLE5504AUX for Use with Wired C-Bus Networks Instruction Bulletin Retain for future use. Square D Clipsal DIN-Rail Four-Channel Auxiliary Input

More information

EcoSystem Bus Supply CS - - 1L: CS-1L-CM, CS-1L-WM, CS-2L-CM, CS-2L-WM. Bus Supply. EcoSystem

EcoSystem Bus Supply CS - - 1L: CS-1L-CM, CS-1L-WM, CS-2L-CM, CS-2L-WM. Bus Supply. EcoSystem EcoSystem Front Face (CS-1L shown) E1 E1 E2 Top Side View (CS-1L shown) E2 CS-xL-xM 10.29.09 An EcoSystem lighting network containing more than one ballast, module, or driver requires an EcoSystem. This

More information

TrueAlarm Fire Alarm Systems

TrueAlarm Fire Alarm Systems TrueAlarm Systems UL, ULC, CSFM Listed; FM Approved* Network Annunciators; es Features Provides a dedicated local area network (LAN) for connection of a TrueSite workstation server to remote clients: es

More information

Telephone- and leased line modem for industrial applications TD-36

Telephone- and leased line modem for industrial applications TD-36 Telephone- and leased line modem for industrial applications TD-36 Modem for industrial PSTN- and leased line applications The TD-36 is an analogue V.34 PSTN modem as well as an industrial 2-wire leased

More information

Protective Signaling Systems Wiring Practices Manual

Protective Signaling Systems Wiring Practices Manual Protective Signaling Systems Wiring Practices Manual Edwards Signaling Products 90 Fieldstone Court, Cheshire, CT 06410-1212 Edwards Protective Signaling System Wiring Practices INTRODUCTION The installation

More information

D7050/D7050TH. Installation Instructions. Multiplex Photoelectric Smoke Detectors

D7050/D7050TH. Installation Instructions. Multiplex Photoelectric Smoke Detectors D7050/D7050TH EN Installation Instructions Multiplex Photoelectric Smoke Detectors D7050/D7050TH Installation Instructions.0 Description Notices These instructions cover the installation of the D7050/D7050TH

More information

Instruction Bulletin. POWERLINK RS232 to 485 Converter. for use with POWERLINK G3 Systems INTRODUCTION SAFETY PRECAUTIONS CLASS A FCC STATEMENT

Instruction Bulletin. POWERLINK RS232 to 485 Converter. for use with POWERLINK G3 Systems INTRODUCTION SAFETY PRECAUTIONS CLASS A FCC STATEMENT Instruction Bulletin 63249-420-317A1 01/2009 POWERLINK RS232 to 485 Converter for use with POWERLINK G3 Systems INTRODUCTION SAFETY PRECAUTIONS The POWERLINK G3 Controllers are used to control the operation

More information

SCREENLOGIC INTERFACE WIRELESS CONNECTION KIT

SCREENLOGIC INTERFACE WIRELESS CONNECTION KIT SCREENLOGIC INTERFACE WIRELESS CONNECTION KIT FOR INTELLITOUCH AND EASYTOUCH CONTROL SYSTEMS INSTALLATION GUIDE IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS Technical

More information

Advantium 2 Plus Alarm

Advantium 2 Plus Alarm ADI 9510-B Advantium 2 Plus Alarm INSTALLATION AND OPERATING INSTRUCTIONS Carefully Read These Instructions Before Operating Carefully Read These Controls Corporation of America 1501 Harpers Road Virginia

More information

Perle Protocol Transparent Media Converter Modules

Perle Protocol Transparent Media Converter Modules Perle Protocol Transparent Media Converter Modules Installation Guide C-4GPT-DSFP CM-4GPT-DSFP Part# 5500335-10 Overview This document contains instructions necessary for the installation and operation

More information

Secure Ethernet Gateway SEG-1 and SEG-M for IEI Access Systems Installation Manual

Secure Ethernet Gateway SEG-1 and SEG-M for IEI Access Systems Installation Manual Secure Ethernet Gateway SEG-1 and SEG-M for IEI Access Systems Installation Manual Section 1: Introduction SECURITY WARNING: New SEG's shipped after April 2008 will have Telnet setup option enabled by

More information

LocoNet, the Digitrax Difference

LocoNet, the Digitrax Difference LocoNet, the Digitrax Difference LocoNet is Digitrax's method of communication between LocoNet compatible devices on a model railroad layout. LocoNet Compatible devices are designed to work together on

More information

Características. Starligh SA 9 de julio 1595 Córdoba Argentina - 0351-4809210 / 4119600

Características. Starligh SA 9 de julio 1595 Córdoba Argentina - 0351-4809210 / 4119600 Balun Activo - BALUN_ACT Características Single Channel Active Video Transmitter Full-motion color video signal up to 3900ft(1200m) via UTP cat5e/6 NTSC, PAL & SECAM video format compatible Real-time transmission

More information

Comm5 Wiring Installation

Comm5 Wiring Installation Comm5 Wiring Installation This wiring information applies to the following Trane products: Tracer Summit systems (Comm5 communications, Version 12.0 and higher) Tracker systems (BMTK models) Tracer loop

More information

USER S GUIDE MEDIA CONVERTER TECHNICAL SPECIFICATIONS. Host Connection

USER S GUIDE MEDIA CONVERTER TECHNICAL SPECIFICATIONS. Host Connection MEDIA CONVERTER TECHNICAL SPECIFICATIONS Host Connection IBM 7x or 7x Cluster Controller Case dimensions 4.75" x.0" x.0" (9mm x 7mm x 5mm) Shipping Weight pounds (0.9 kilograms) Environment Temperature:

More information

StructureScan HD Module. Installation Guide ENGLISH. www.bandg.com www.simrad-yachting.com www.lowrance.com

StructureScan HD Module. Installation Guide ENGLISH. www.bandg.com www.simrad-yachting.com www.lowrance.com StructureScan HD Module Installation Guide ENGLISH www.bandg.com www.simrad-yachting.com www.lowrance.com Disclaimer As Navico is continuously improving this product, we retain the right to make changes

More information

4100U/4100ES to TFX Fire Fighter Phone System Installation Instructions

4100U/4100ES to TFX Fire Fighter Phone System Installation Instructions 4100U/4100ES to TFX Fire Fighter Phone System Installation Instructions Introduction This publication describes the installation procedure for the 4100U/4100ES to TFX Fire Fighter s Phone card used to

More information

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT ... ... Spur 2. Spur 1. Zone 1. Zone 0

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT ... ... Spur 2. Spur 1. Zone 1. Zone 0 FieldBarrier Features Assembly 8... 12 outputs Ex ia IIC, FISCO and Entity Advanced fault isolation and diagnostics at the spur FieldBarrier in Zone 1/Div. 2 Instruments in Zone 0...1/Div. 1 For FOUNDATION

More information

Contents. Document information

Contents. Document information User Manual Contents Document information... 2 Introduction... 3 Warnings... 3 Manufacturer... 3 Description... Installation... Configuration... Troubleshooting...11 Technical data...12 Device Scope: PCB

More information

HM-W536 Install Guide

HM-W536 Install Guide HM-W536 Install Guide 9/13/2013 IMPORTANT SAFETY INSTRUCTIONS Warning - When using electrical devices, basic safety precautions should be followed to reduce the risk of fire, electrical shock or injury.

More information

User s Manual RF Wireless Receiver

User s Manual RF Wireless Receiver User s Manual Model 15 MHz Remote Control Receiver TL-RX-15 User Manual Contents 1. General Descriptions... P.2 2. Receiver Package Description... P.. Specifications... P. 4. Installation & Connections...

More information

AXIS 291 1U Video Server Rack Installation Guide

AXIS 291 1U Video Server Rack Installation Guide AXIS 291 1U Video Server Rack Installation Guide About This Document This document describes how to install Axis blade video servers in the AXIS 291 1U Video Server Rack. Updated versions of this document

More information

Kvaser Mini PCI Express User s Guide

Kvaser Mini PCI Express User s Guide Kvaser Mini PCI Express User s Guide Copyright 2013-2014 Kvaser AB, Mölndal, Sweden http://www.kvaser.com Printed Sunday 28 th September, 2014 We believe that the information contained herein was accurate

More information

ScreenLogic Wireless Connection Kit. Installation Guide. pool/spa control system

ScreenLogic Wireless Connection Kit. Installation Guide. pool/spa control system pool/spa control system ScreenLogic Wireless Connection Kit Installation Guide P/N 520663 - Rev B 8 Technical Support Contact Technical Support at: Sanford, North Carolina (8 A.M. to 5 P.M.) Phone: (800)

More information

CONTENTS. DI-9204Exd Digital Flame-proof Manual Call Point Installation and Operation Manual

CONTENTS. DI-9204Exd Digital Flame-proof Manual Call Point Installation and Operation Manual DI-9204Exd Digital Flame-proof Manual Call Point CONTENTS 1 General... 1 2 Features... 1 3 Technical Specifications... 1 4 Construction and Operation Principle... 2 4.1 Exterior View... 2 4.2 Operation

More information

Coax Twisted Pair Balun Coax Twisted Pair Balun w/cable Mini Coax Twisted Pair Balun

Coax Twisted Pair Balun Coax Twisted Pair Balun w/cable Mini Coax Twisted Pair Balun AUGUST 1993 IC002, IC018A IC019A, IC033 IC069A, IC070A IC071A Coax Twisted Pair Balun Coax Twisted Pair Balun w/cable Mini Coax Twisted Pair Balun CUSTOMER SUPPORT INFORMATION Order toll-free in the U.S.

More information

Application Note - Connecting an Electricity Meter to SolarEdge Devices (Europe and APAC)

Application Note - Connecting an Electricity Meter to SolarEdge Devices (Europe and APAC) February 2015 February 2015 Application Note - Connecting an Electricity Meter to SolarEdge Devices (Europe and APAC) This document describes how to connect an electricity meter to a SolarEdge device (inverters,

More information

MicroTech III Rooftop and Self Contained Unit Controller LONWORKS Communication Module

MicroTech III Rooftop and Self Contained Unit Controller LONWORKS Communication Module Installation and Maintenance Manual Group: Controls Part Number: IM 918 Date: April 2012 Supercedes: IM 918-1 MicroTech III Rooftop and Self Contained Unit Controller LONWORKS Communication Module RoofPak

More information

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information. Product and Applications Description The power supply units N 125/x2 can supply DC 24 V power from an additional pair of terminals (yellowwhite). This DC 24 V output voltage can be used to power e.g. an

More information

LONWORKS Fibre Optic Converter

LONWORKS Fibre Optic Converter LONWORKS Fiber Optic Converter LRW-102 and LRW-102/PP LONWORKS to fibre optic link, multidrop and redundant ring applications The LRW-102 is a fibre optic modem designed for multidrop and redundant ring

More information

FDCI222, FDCIO222, FDCIO224 Input module Input/output modules

FDCI222, FDCIO222, FDCIO224 Input module Input/output modules FDCI222, FDCIO222, FDCIO224 Input module Input/output modules addressable (FDnet/C-NET) Sinteso Cerberus PRO Input module FDCI222 with 4 monitored contact inputs for the acknowledgement of technical states

More information

ZC-24DO CANopen I/O Module: 24 Digital Outputs

ZC-24DO CANopen I/O Module: 24 Digital Outputs Z-PC Line EN ZC-24DO CANopen I/O Module: 24 Digital Outputs Installation Manual Contents: - General Specifications - Technical Specifications - Installation Rules - Electrical connections - DIP-switches

More information

TX SAW MID 5V TRANSMITTER

TX SAW MID 5V TRANSMITTER TX SAW MID 5V TRANSMITTER SAW Transmitter module with external antenna, for utilisations with ON-OFF modulation of a RF carrier with digital data. Buffer stage for enhanced power and low harmonics on output

More information

Model VBP04VPS28 Features Overview

Model VBP04VPS28 Features Overview Model VBP04VPS28 Features Provides camera power while receiving video transmission both over one single 4-pair UTP cat5e/6 cable Power camera; total power consumption: 100W Color Video + Power up to 984ft(300m)

More information

ABB Drives. User s Manual HTL Encoder Interface FEN-31

ABB Drives. User s Manual HTL Encoder Interface FEN-31 ABB Drives User s Manual HTL Encoder Interface FEN-31 HTL Encoder Interface FEN-31 User s Manual 3AUA0000031044 Rev B EN EFFECTIVE: 2010-04-06 2010 ABB Oy. All Rights Reserved. 5 Safety instructions

More information

GS005. Alarm / on-off signal transmitter. GS series of wireless industrial sensors. Features: General Description: Applications:

GS005. Alarm / on-off signal transmitter. GS series of wireless industrial sensors. Features: General Description: Applications: GS series of wireless industrial sensors Alarm / on-off signal transmitter Features: Input: two wires to detect contact closure or opening Fast 40 msec typical delay for alarm reception on remote receiver

More information

1993 ACCESSORIES & EQUIPMENT Volkswagen Instrument Panels. Volkswagen; EuroVan, Passat

1993 ACCESSORIES & EQUIPMENT Volkswagen Instrument Panels. Volkswagen; EuroVan, Passat Article Text Saturday, March 18, 2000 10:33PM ARTICLE BEGINNING 1993 ACCESSORIES & EQUIPMENT Volkswagen Instrument Panels Volkswagen; EuroVan, Passat DESCRIPTION & OPERATION Instrument cluster for most

More information

Rack mounted telephone- and leased line modem for industrial applications

Rack mounted telephone- and leased line modem for industrial applications Rack mounted telephone- and leased line modem for industrial applications TR-6 Rack modem for industrial PSTNand /-wire leased line applications The TR-6 is an analogue V. 9 -rack PSTN modem as well as

More information

3x cinch/s-video socket Order no.: 33 1532 xx. USB/3.5 mm audio socket Order no.: 33 1539 xx. VGA socket Order no.: 33 1540 xx

3x cinch/s-video socket Order no.: 33 1532 xx. USB/3.5 mm audio socket Order no.: 33 1539 xx. VGA socket Order no.: 33 1540 xx 3x cinch/s-video socket Order no.: 33 1532 xx USB/3.5 mm audio socket Order no.: 33 1539 xx VGA socket Order no.: 33 1540 xx VGA socket with screw-in lift terminals Order no.: 33 1541 xx High definition

More information

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs E031026 000823 Process modules Digital input PMI for inputs for 120 V AC inputs PMI Input E4, E5, GND L- PMI 120 V AC Input E4, E5, Common C E6, E7, GND L- E6, E7, Common C LEDs for the inputs operation

More information

IAdea GPIO Extender Application Note

IAdea GPIO Extender Application Note IAdea GPIO Extender Application Note Contents Introduction... 1 What is GPIO Extender?... 1 Digital Input and Output Applications... 2 Wiring Instructions... 4 Software Instructions... 7 Setup Example

More information

Alarm over IP. IRIS Touch Home Installation Manual. Version 1.0 ENGLISH. Now certified and compliant with EN50131, EN50136 Security Grade 4 ATS6

Alarm over IP. IRIS Touch Home Installation Manual. Version 1.0 ENGLISH. Now certified and compliant with EN50131, EN50136 Security Grade 4 ATS6 Alarm over IP IRIS Touch Home Installation Manual Version 1.0 ENGLISH Now certified and compliant with EN50131, EN50136 Security Grade 4 ATS6 1. Introduction No more bulky batteries, just one sleek unit

More information

Wiring SIMATIC. Wiring. Overview 1. Wiring rules. Wiring the mains connection plug 3. Wiring the load current supply (PM) to the CPU 4

Wiring SIMATIC. Wiring. Overview 1. Wiring rules. Wiring the mains connection plug 3. Wiring the load current supply (PM) to the CPU 4 Overview 1 rules 2 SIMATIC Getting Started the mains connection plug 3 the load current supply (PM) to the CPU 4 Potential bridge circuits 5 the digital input module 6 the digital output module 7 front

More information

INSTRUCTION SHEET. Eaton Logic Controller PROFIBUS DP Distributed I/O Adapter Module. [Applicable Distributed I/O Adapter Module] ELC-CAPBDP

INSTRUCTION SHEET. Eaton Logic Controller PROFIBUS DP Distributed I/O Adapter Module. [Applicable Distributed I/O Adapter Module] ELC-CAPBDP 2010-12-10 5012603601-ECB1 Eaton Logic Controller PROFIBUS DP Distributed I/O Adapter Module INSTRUCTION SHEET [Applicable Distributed I/O Adapter Module] ELC-CAPBDP IL05004009E 002-1215820-02 Thank you

More information

MACTek Corporation. USB HART Interface. Users Manual

MACTek Corporation. USB HART Interface. Users Manual MACTek Corporation USB HART Interface DM01003100AA February, 2003 LIMITED WARRANTY VIATOR Interface for HART MACTek Corporation warrants this Interface and all of its component against defects in materials

More information

connecdim Gateway G1 Ethernet TCP/IP to DALI

connecdim Gateway G1 Ethernet TCP/IP to DALI Gateway G1 Ethernet TCP/IP to LI Independent lighting control for up to 256 LI gears on 4 LI lines Can be expanded by connecting multiple gateways on the same network Cloud based web interface for configuration

More information

Manual. Simrad StructureScan LSS-1 Sonar Module. English

Manual. Simrad StructureScan LSS-1 Sonar Module. English Manual Simrad StructureScan LSS-1 Sonar Module English www.simrad-yachting.com A brand by Navico - Leader in Marine Electronics Disclaimer As Navico is continuously improving this product, we retain the

More information

Kvaser Mini PCI Express HS User's Guide

Kvaser Mini PCI Express HS User's Guide Kvaser Mini PCI Express HS User's Guide Copyright 2011-2013 Kvaser AB, Mölndal, Sweden http://www.kvaser.com Last updated Wednesday, 18 September 2013 We believe that the information contained herein was

More information

A0320 Micro-USB Bluetooth Wall-Dock for Distributed Audio

A0320 Micro-USB Bluetooth Wall-Dock for Distributed Audio A0320 Micro-USB Bluetooth Wall-Dock for Distributed Audio Intelligent Entertainment Infrastructure Security Solutions The A0320 is an on-wall bluetooth docking station that will charge a Micro-USB device.

More information

ASSEMBLY, INSTALLATION, AND REMOVAL OF CONTACTS AND MODULES

ASSEMBLY, INSTALLATION, AND REMOVAL OF CONTACTS AND MODULES ASSEMBLY, INSTALLATION, AND REMOVAL OF CONTACTS AND MODULES FOR 50 OHM COAXIAL CONTACTS AND MODULES TABLE OF CONTENTS SECTION 1 RECEIVER CONTACT ASSEMBLY INSTRUCTIONS SECTION 2 ITA CONTACT ASSEMBLY INSTRUCTIONS

More information

This Datasheet for the IC660BBA100. Block 115Vac Analog 4 Inputs / 2 Outputs.

This Datasheet for the IC660BBA100. Block 115Vac Analog 4 Inputs / 2 Outputs. This Datasheet for the IC0BBA00 Block 5Vac Analog Inputs / Outputs http://www.cimtecautomation.com/parts/p--ic0bba00.aspx Provides the wiring diagrams and installation guidelines for this GE Series 90-0

More information

8-Port 10/100M N-Way Mini Switch

8-Port 10/100M N-Way Mini Switch 1 8-Port 10/100M N-Way Mini Switch User Guide Introduction 2 This user guide is applied to the 8 ports 10/100M N-Way Mini Switch. The 8-Port 10/100M N-Way Mini Switch is designed for easy installation

More information

About Your NetBotz 4-20mA Sensor Pod

About Your NetBotz 4-20mA Sensor Pod Thank you for purchasing this NetBotz 4-20mA Sensor Pod. Each 4-20mA Sensor Pod enables you to connect up to four 4-20mA sensors to your NetBotz 420 or NetBotz 500 appliance. Hundreds of 4-20mA sensors

More information

Features, Benefits, and Operation

Features, Benefits, and Operation Features, Benefits, and Operation 2014 Decibel Eleven Contents Introduction... 2 Features... 2 Rear Panel... 3 Connections... 3 Power... 3 MIDI... 3 Pedal Loops... 4 Example Connection Diagrams... 5,6

More information

Video Splitter VS-104 / VS-108 User's Manual

Video Splitter VS-104 / VS-108 User's Manual Video Splitter VS-104 / VS-108 User's Manual VS-1048 07-11-02 Page 1 of 6 Packing Checklist 1 VS-104/VS-108 Video Splitter 1 DC 9V 300mA (min.) Power Adapter 1 User's Manual Please read this manual thoroughly

More information

Model 70A00-1. GSM Cellular Communications Center

Model 70A00-1. GSM Cellular Communications Center Home Automation, Inc. Model 70A00-1 GSM Cellular Communications Center Operation Manual Document Number 70I00-1 Rev A August, 2009 Contents Description... 1 Use with security systems...1 Everyday use...2

More information

Installation Instructions Model SIM-16

Installation Instructions Model SIM-16 2 2 Installation Instructions Model SIM- Supervised Input Module (- / S22-B2-A2) TB SIM- 2 7 8 9 2 INTRODUCTION The SIEMENS Model SIM- Supervised Input Module is a remotely located, general purpose input

More information

Infinity 1U 19 Converter Shelf

Infinity 1U 19 Converter Shelf GE Critical Power Quick Start Guide Infinity 1U 19 Converter Shelf Models: for systems with controllers: for systems without controllers: L219 primary (with controller) or supplemental, L222 supplemental

More information

Duct Humidity Transmitter

Duct Humidity Transmitter SDC-H Duct Humidity Transmitter Features Replaceable sensor element Humidity measurement for air ducts Minimum and maximum value memory 0 0V, 0 0mA or 0V, 4 0mA measuring signals selectable with jumpers

More information

VIP-802 DUAL ENHANCED NETWORK AUDIO PORT

VIP-802 DUAL ENHANCED NETWORK AUDIO PORT ISSUE 5 VIP-802 DUAL ENHANCED NETWORK AUDIO PORT INTRODUCTION The VIP-802 Dual Enhanced Network Audio Port enables voice access to two zones of one-way paging over an IP network, allowing page zones to

More information

1 IPDACT - Internet Protocol Digital Alarm Communicator/ Transmitter

1 IPDACT - Internet Protocol Digital Alarm Communicator/ Transmitter IP Communicator Series Product Installation Document PN 53109:I 4/26/2010 10-xxx 1 IPDACT - Internet Protocol Digital Alarm Communicator/ Transmitter The IPDACT, IPDACT-2 and IPDACT-2UD are compact, Internet

More information

INSTALLATION MANUAL. ST-CCTV-VBAC-POEPTZ 1 Channel Power Over Ethernet UTP Active Video Balun Transceiver

INSTALLATION MANUAL. ST-CCTV-VBAC-POEPTZ 1 Channel Power Over Ethernet UTP Active Video Balun Transceiver INSTALLATION MANUAL ST-CCTV-VBAC-POEPTZ 1 Channel Power Over Ethernet UTP Active Video Balun Transceiver Copyright North American Cable Equipment, Inc. 1 PACKAGE CONTENTS This package contains: One ST-CCTV-VBACT-POEPTZ

More information

SPR-5200 and SPR-4600 Installation and Operation Manual

SPR-5200 and SPR-4600 Installation and Operation Manual SPR-5200 and SPR-4600 Installation and Operation Manual SunPower Corporation Document # 001 69178 Rev** 1 SunPower Inverter SPR-5200 and SPR-4600 Table of Contents SunPower Corporation Document # 001 69178

More information

Schneider Automation Modbus Plus Network Installing Clustered Node Devices 31000939 00 Version 2.0

Schneider Automation Modbus Plus Network Installing Clustered Node Devices 31000939 00 Version 2.0 Schneider Automation Modbus Plus Network Installing Clustered Node Devices 3000939 00 Version.0 Modbus Plus devices must be installed as specified in a network layout plan, showing each device s mounting

More information

DX4010V2. Installation Instructions. RS-232/USB Serial Interface Module

DX4010V2. Installation Instructions. RS-232/USB Serial Interface Module DX4010V2 EN Installation Instructions RS-232/USB Serial Interface Module DX4010V2 Installation Instructions Trademarks Trademarks BlackBox is either a registered trademark or a trademark of BlackBox Corporation

More information

ImproX IXP20 Controller INSTALLATION MANUAL

ImproX IXP20 Controller INSTALLATION MANUAL MODEL NUMBER: ISC910-1-0-GB-XX ISC911-5-0-GB-XX IXP20 CONTROLLER SPECIFICATIONS Working Environment Plastic Housing... Power ImproX IXP20 Controller INSTALLATION MANUAL Designed to work in an indoor (dry)

More information

AXIS T81B22 DC 30W Midspan

AXIS T81B22 DC 30W Midspan INSTALLATION GUIDE AXIS T81B22 DC 30W Midspan ENGLISH About this Document This document includes instructions for installing AXIS T81B22 on your network. Previous experience of networking will be beneficial

More information

Diffuse reflection light scanner with background suppression. Dimensioned drawing

Diffuse reflection light scanner with background suppression. Dimensioned drawing FRK 93 Diffuse reflection light scanner with background suppression Dimensioned drawing We reserve the right to make changes 93_d1gb.fm Part No. 51 1169 1-3 V DC 15 75m m Scanner with foreground and background

More information

Achat 115MA full-range speaker. user manual

Achat 115MA full-range speaker. user manual Achat 115MA full-range speaker user manual Musikhaus Thomann Thomann GmbH Hans-Thomann-Straße 1 96138 Burgebrach Germany Telephone: +49 (0) 9546 9223-0 E-mail: info@thomann.de Internet: www.thomann.de

More information

Fire Fighter Phone System Installation Instructions

Fire Fighter Phone System Installation Instructions Fire Fighter Phone System Installation Instructions Introduction This publication describes the installation procedure for the Fire Fighter s Phone on a 4100U or a 4100ES Fire Alarm Control Panel (FACP).

More information

OH720, OP720, HI720, HI722 Automatic fire detectors

OH720, OP720, HI720, HI722 Automatic fire detectors OH720, OP720, HI720, HI722 Automatic fire detectors For the automatic addressable detector bus C-NET Cerberus PRO The optimum smoke detector for all applications Signal processing with detection algorithms

More information

EX-RC1 Remote I/O Adapter

EX-RC1 Remote I/O Adapter EX-RC1 Remote I/O Adapter The EX-RC1 interfaces between Unitronics Vision OPLCs and remote I/O Expansion Modules distributed throughout your system. The adapter is connected to a PLC via CANbus. Each adapter

More information

SLATE. Analog I/O Module INSTALLATION INSTRUCTIONS R8001U3001

SLATE. Analog I/O Module INSTALLATION INSTRUCTIONS R8001U3001 SLATE Analog I/O Module R8001U3001 INSTALLATION INSTRUCTIONS Scan for more information Application SLATE brings configurable safety and programmable logic together into one single platform. The platform

More information

MY Radio/Navigation System (RNS) with multi-function display (MFD) and TV. => Operating instructions. => Self-study programme No.

MY Radio/Navigation System (RNS) with multi-function display (MFD) and TV. => Operating instructions. => Self-study programme No. Y Radio/Navigation System (RNS) with multi-function display (FD) and TV Warning! Before working on the electrical system disconnect the battery earth strap. Notes: u When faced with complaints it is absolutely

More information

Component/Composite Video Balun

Component/Composite Video Balun JUNE 2004 IC462A Component/Composite Video Balun CUSTOMER SUPPORT INFORMATION Order toll-free in the U.S.: Call 877-877-BBOX (outside U.S. call 724-746-5500) FREE technical support 24 hours a day, 7 days

More information

CCTV Passthrough Balun

CCTV Passthrough Balun JUNE 2004 IC452A CCTV Passthrough Balun CUSTOMER SUPPORT INFORMATION Order toll-free in the U.S.: Call 877-877-BBOX (outside U.S. call 724-746-5500) FREE technical support 24 hours a day, 7 days a week:

More information

INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930

INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930 INSTALLATION GUIDE Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930 Card Reader and Controller Model 3.5 with KIM Swipe Reader Table of Contents 1. Features..................................

More information