IMMS-CCC. IMMS-CCC Hardwire Central Interface. Installation Instructions

Save this PDF as:
 WORD  PNG  TXT  JPG

Size: px
Start display at page:

Download "IMMS-CCC. IMMS-CCC Hardwire Central Interface. Installation Instructions"

Transcription

1 IMMS-CCC IMMS-CCC Hardwire Central Interface Installation Instructions

2 TABLE OF CONTENTS... Choose a Location... 1 Connections... 2 Operations... 3 Software Configuration... 4 Troubleshooting... 5 Loopback Test... 6

3 CHOOSE A LOCATION... Choose a cool, dry, safe, indoor location. The IMMS-CCC central interface must be located within 6 ft. (2 m) of the computer itself. It may be positioned on or under a desktop, but the indicator lights on the front panel should be visible to the operator. NOT FOR OUTDOOR USE. 1

4 CONNECTIONS... There are 3 cables to connect to the rear of the CCC. 1. GCBL Cable: Route the GCBL communications cable (leading to the Site Interface) to the rear panel of the CCC. Strip the black outer jacket of the GCBL cable, and excess foil shield, back approximately 2" (50 mm). Strip approximately 3 16" (4.5 mm) from each individual wire and connect to the green communications terminals, in the area labeled From CCC, observing the color codes. Color Red Black Blue Orange Terminal SI1 SI2 SI3 SI4 2 SI 1 SI 2 SI 3 SI 4 SI 5 To Site Interface To PC 24 VAC 3 GCBL Cable Grounding: Twist a length of bare copper wire together with the bare silver ground wire in the GCBL cable, and connect them together to the gray SI5 terminal. Route the other end of the bare copper wire to an approved earth ground (recommended impedance of 10 Ohms or less). 1 2

5 2. Serial Cable: Connect the male end of the included DB-9 serial cable to the back of the CCC and secure with the captive screws on the connector. Connect the other (female) end of the cable to a working serial port on the computer. Serial cable should be 6 ft. (2 m) or less for best results. 3. Power Transformer: Connect the power cable from the transformer to the 24 VAC plug on the rear of the CCC. The connector has a pin to position it correctly, and should only be connected one way. Rotate the connector until the pin engages the receptacle, and gently push the connector in. Plug the transformer into AC power, or through a surgeprotected power outlet (not included). OPERATIONS... The CCC has no controls of its own. No operations are possible directly from the CCC. 3

6 SOFTWARE CONFIGURATION... To complete the IMMS-CCC installation, the computer must be connected with the IMMS software installed. The computer must have the IMMS hardware key installed (USB or parallel port) in order to communicate. From the Home screen in the IMMS software, go to the Hardware tab for the IMMS System, and locate the System Synchronization section of the screen. Select a Com Port (1-4) for CCC Port and click the Test button. Observe the LED lights on the front of the CCC. The Transmit light is active when the CCC is sending a signal out, and the Receive LED is active whenever the CCC is receiving a response. In normal communications, these activities occur very quickly, so you may observe both lights blinking very rapidly. IMMS will indicate whether the test passed or failed after a few seconds. You may try another port if the test fails, until all ports have been tried. If none of the ports is successful, troubleshoot the CCC or contact Hunter Technical Services. 4

7 TROUBLESHOOTING... The Power LED should light when the transformer is plugged into the primary AC power source (if not, check power source). Power light, but no Transmit or Receive lights during communications, may indicate bad serial cable, bad serial port, or incorrect software communications configuration (Synchronization Settings). Power light and Transmit light, but no Receive light, indicates correct software settings but may indicate bad serial cable, GCBL communications cable fault, or SI problem. Perform Loopback Test at both locations (CCC and SI). 5

8 LOOPBACK TEST... To perform this test at the CCC, you will need two short (4 in./10 cm) pieces of insulated 18 AWG (1 mm) wire, or a very short piece of GCBL cable. 1. Connect terminals 1 and 4 together with one piece of wire. 2. Connect terminals 2 and 3 together with another length of wire. 3. Perform the CCC Port Test from the IMMS software. If successful, the report will be Loopback Test Passed. This verifies that the CCC is operating correctly. SI 1 SI 2 SI 3 SI 4 SI 5 You can also use this function to check the GCBL communications cable in the field: 1. At the SI location, disconnect the GCBL from the SI. 2. Connect the Red and Orange wires together. 3. Connect the Black and Blue wires together. Do not let them touch the Red and Orange wires. Perform the CCC Port Test again from the IMMS software. If successful, this test verifies that the wire run to the field location is intact. If the test passes at the CCC, but fails at the SI location, there is most likely a fault in the communications cable itself. To Site Interface To PC 24 VAC Hunter Industries Incorporated The Irrigation Innovators 2004 Hunter Industries Incorporated 1940 Diamond Street San Marcos, California LIT-386 5/04

USB Serial RS232 Loop-back test and troubleshooting

USB Serial RS232 Loop-back test and troubleshooting USB Serial RS232 Loop-back test and troubleshooting A loop-back test can verify if your USB to serial RS232 adapter has been installed properly and if it can send and receive data as intended. In a troubleshooting

More information

DX4010V2. Installation Instructions. RS-232/USB Serial Interface Module

DX4010V2. Installation Instructions. RS-232/USB Serial Interface Module DX4010V2 EN Installation Instructions RS-232/USB Serial Interface Module DX4010V2 Installation Instructions Trademarks Trademarks BlackBox is either a registered trademark or a trademark of BlackBox Corporation

More information

ACC-COM-LAN Communications Module (for Ethernet connections)

ACC-COM-LAN Communications Module (for Ethernet connections) ACC-COM-LAN Communications Module (for Ethernet connections) NEW ACC-COM-LAN Communications Module (for Ethernet connections) Owner s Manual & Installation Instructions A Table of Contents introduction..............................................

More information

Troubleshooting Tips Lifestyle SA-2 & SA-3 Amplifier. Troubleshooting Tips

Troubleshooting Tips Lifestyle SA-2 & SA-3 Amplifier. Troubleshooting Tips Troubleshooting Tips Lifestyle SA-2 & SA-3 Amplifier Refer to the Lifestyle SA-2 & SA-3 Amplifier service manuals, part number 271720 for schematics, PCB layouts and parts lists. Preventative Repair Measures

More information

Warnings: This manual is intended to guide a technicians or customers who would like to repair DBL's

Warnings: This manual is intended to guide a technicians or customers who would like to repair DBL's DBL's Service Manual Warnings: This manual is intended to guide a technicians or customers who would like to repair DBL's devices (GoIP, SIM Bank, FXS/FXO gateways) at his/her own risk. DBL SHALL NOT be

More information

USB 2.0 4-Port Extender Kit

USB 2.0 4-Port Extender Kit USB 2.0 4-Port Extender Kit 500072 MuxLab Inc. 2014 94-000760-A / SE-000760-A Table of Contents 1. Introduction... 2 2. Features... 2 3. Specifications... 2 4. Package Contents... 3 5. Physical Diagram...

More information

Cabling Specifications

Cabling Specifications APPENDIX A This appendix provides cabling and pinout information for feature cards on the Cisco AS5350XM and Cisco AS5400XM universal gateways. It contains the following sections: 2-Port and 4-Port T1

More information

IP DSLAM IDL-2402. Quick Installation Guide

IP DSLAM IDL-2402. Quick Installation Guide IP DSLAM IDL-2402 Quick Installation Guide Table of Contents Package Contents... 3 Overview... 4 Setup the IDL series IP DSLAM... 5 Safety Instruction... 5 Hardware Installation... 6 WEB Configuration...

More information

HSG Engineering Tech Bulletin

HSG Engineering Tech Bulletin Specifications subject to change OCT 2013; Rev. 1.3 HSG Engineering Tech Bulletin Recommended RS-485 Wiring for NetAXS-4/NetAXS-123 Loops Overview This document provides the recommended RS-485 wiring for

More information

PRODUCTIVITY THROUGH INNOVATION 600 CONTROL DIRECT DRIVE TECHNICAL/OPERATION MANUAL

PRODUCTIVITY THROUGH INNOVATION 600 CONTROL DIRECT DRIVE TECHNICAL/OPERATION MANUAL Rev. D PRODUCTIVITY THROUGH INNOVATION 600 CONTROL DIRECT DRIVE TECHNICAL/OPERATION MANUAL 10 BORIGHT AVENUE, KENILWORTH NEW JERSEY 07033 TELEPHONE: 800-524-0273 FAX: 908-686-9317 TABLE OF CONTENTS Page

More information

Programming and Using the Courier V.Everything Modem for Remote Operation of DDF6000

Programming and Using the Courier V.Everything Modem for Remote Operation of DDF6000 Programming and Using the Courier V.Everything Modem for Remote Operation of DDF6000 1.0 Introduction A Technical Application Note from Doppler System July 5, 1999 Version 3.x of the DDF6000, running version

More information

USB 2.0 RG Port USB m CAT 5e/6/7 Extender System. User Guide

USB 2.0 RG Port USB m CAT 5e/6/7 Extender System. User Guide USB 2.0 RG2304 4-Port USB 2.0 100m CAT 5e/6/7 Extender System User Guide Thank you for purchasing the USB 2.0 RG2304 Extender System. Please read this guide thoroughly. This document applies to Part Numbers:

More information

AUDITVIEW USER INSTRUCTIONS

AUDITVIEW USER INSTRUCTIONS The AuditGard AuditView software allows the Manager to view, save, and print the audit records. The AuditGard lock maintains the last 512 lock events in non-volatile memory. Accessing the audit records

More information

Programming & Installing the Premier RF Modem for a Serial Connection to your PC

Programming & Installing the Premier RF Modem for a Serial Connection to your PC Programming & Installing the Premier RF Modem for a Serial Connection to your PC NOTE: JM Stewart utilizes an industrial 900 MHz RF Modem from FreeWave Technologies, model FGR 115RC. The FreeWave Wireless

More information

Quick Installation Guide. Live! Titanium

Quick Installation Guide. Live! Titanium Quick Installation Guide Live! Titanium Contents 1. Live! overview... 2. Installation... 3. Network setup... 4. Wireless setup... 5. Configuring your Live!... 6. Troubleshooting... 2 4 7 8 9 10 1 1. Live!

More information

FTDI VCP DRIVER (free) (WIN/MAC/LINUX) http://www.ftdichip.com/drivers/vcp.htm

FTDI VCP DRIVER (free) (WIN/MAC/LINUX) http://www.ftdichip.com/drivers/vcp.htm 002 - CONNECTING THE PRINTER Now that you have an idea what 3D printing entails, we can continue and connect the printer to your computer. First make sure you have a computer with a decent amount of RAM

More information

Coax Twisted Pair Balun Coax Twisted Pair Balun w/cable Mini Coax Twisted Pair Balun

Coax Twisted Pair Balun Coax Twisted Pair Balun w/cable Mini Coax Twisted Pair Balun AUGUST 1993 IC002, IC018A IC019A, IC033 IC069A, IC070A IC071A Coax Twisted Pair Balun Coax Twisted Pair Balun w/cable Mini Coax Twisted Pair Balun CUSTOMER SUPPORT INFORMATION Order toll-free in the U.S.

More information

RS232C < - > RS485 CONVERTER S MANUAL. Model: LD15U. Phone: 91-79-4002 4896 / 97 / 98 (M) 0-98253-50221 www.interfaceproducts.info

RS232C < - > RS485 CONVERTER S MANUAL. Model: LD15U. Phone: 91-79-4002 4896 / 97 / 98 (M) 0-98253-50221 www.interfaceproducts.info RS232C < - > RS485 CONVERTER S MANUAL Model: LD15U INTRODUCTION Milestone s model LD-15U is a RS232 to RS 485 converter is designed for highspeed data transmission between computer system and or peripherals

More information

Connecting External Resources

Connecting External Resources Connecting External esources This section describes how to connect the following external resources to Expression 303: power network external sound system SMAT Board guest laptop Connecting the Power Cord

More information

LDG DTS-4/4R Desktop Coaxial Switch / Remote

LDG DTS-4/4R Desktop Coaxial Switch / Remote LDG DTS-4/4R Desktop Coaxial Switch / Remote LDG Electronics 1445 Parran Road, PO Box 48 St. Leonard MD 20685-2903 USA Phone: 410-586-2177 Fax: 410-586-8475 ldg@ldgelectronics.com www.ldgelectronics.com

More information

PC Repair Tools Professional Network Installer Tool Kit

PC Repair Tools Professional Network Installer Tool Kit PC Repair Tools Professional Network Installer Tool Kit Installation Manual CTK400LAN 1 Overview The StarTech.com Professional LAN Installation Tool kit provides all the necessary tools to install and

More information

Perle 10/100/1000 Ethernet Extender Modules

Perle 10/100/1000 Ethernet Extender Modules Perle 10/100/1000 Ethernet Extender Modules 10/100 10/100/1000 (Gigabit) ex-1c/cm110-rj ex-1c/cm110-bnc ex-1c/cm110-tb ex-1c/cm1110-rj ex-1c/cm1110-bnc ex-1c/cm1110 -TB Part# 5500331-11 Overview This document

More information

GV- RK1352 Card Reader

GV- RK1352 Card Reader GV- RK1352 Card Reader The GV-RK1352 is a card reader with keypad, designed to recognize PIN codes, identification cards or both. Featured with the Wiegand and RS-485 outputs, the unit can be connected

More information

GSM-EXT Cable Assembly Installation Guide

GSM-EXT Cable Assembly Installation Guide GSM-EXT Cable Assembly Installation Guide For Documentation and Online Support: http://www.security.honeywell.com/hsc/resources/mywebtech General Information The GSM-EXT cable assembly is used to connect

More information

Connector and Cable Specifications

Connector and Cable Specifications APPENDIXB This chapter describes the connector and cable specifications. Connector Specifications, page B-1l Cable and Adapter Specifications, page B-5 Connector Specifications 10/100/1000 Ports, page

More information

Wireless Router Setup Manual

Wireless Router Setup Manual Wireless Router Setup Manual NETGEAR, Inc. 4500 Great America Parkway Santa Clara, CA 95054 USA 208-10082-02 2006-04 2006 by NETGEAR, Inc. All rights reserved. Trademarks NETGEAR is a trademark of Netgear,

More information

OvisLink OV804WVA Quick Installation Guide

OvisLink OV804WVA Quick Installation Guide OvisLink OV804WVA Quick Installation Guide 1 Indicators and Interfaces 1.1 Front Panel LED Color Status Description Power Red DSL Internet Red WAN LAN4-1 Off Power off. The initialization is normal. Initiating.

More information

Application Note - Connecting an Electricity Meter to SolarEdge Devices (Europe and APAC)

Application Note - Connecting an Electricity Meter to SolarEdge Devices (Europe and APAC) February 2015 February 2015 Application Note - Connecting an Electricity Meter to SolarEdge Devices (Europe and APAC) This document describes how to connect an electricity meter to a SolarEdge device (inverters,

More information

UNIVERSAL RS-232/422/485 CONVERTER FA-UNICON

UNIVERSAL RS-232/422/485 CONVERTER FA-UNICON UNIVERSAL RS-// CONVERTER FA-UNICON Universal RS-// Converter The FA-UNICON converter may be used to convert RS- signal levels to RS-/ signal levels or RS-/ signal levels to RS- signal levels. The FA-UNICON

More information

PARAMOUNT ME MOUNTING AND WIRING KITS FOR USE WITH THE TCF-S / IFW / Pyxis Revised 3/18/2008

PARAMOUNT ME MOUNTING AND WIRING KITS FOR USE WITH THE TCF-S / IFW / Pyxis Revised 3/18/2008 PARAMOUNT ME MOUNTING AND WIRING KITS FOR USE WITH THE TCF-S / IFW / Pyxis Revised 3/18/2008 Optec Stock #17496 for TCF-S OR IFW AND PYXIS Optec Stock #17497 for TCF-S OR IFW Optec Stock #17498 for PYXIS

More information

Cisco 1603 R Ethernet/ISDN BRI Modular Router Cable Specifications

Cisco 1603 R Ethernet/ISDN BRI Modular Router Cable Specifications Cisco 1603 R Ethernet/ISDN BRI Modular Router Cable Specifications Document ID: 46785 Contents Introduction Prerequisites Requirements Components Used Conventions Cabling Specifications Console Ethernet

More information

TE100-P21/TEW-P21G Windows 7 Installation Instruction

TE100-P21/TEW-P21G Windows 7 Installation Instruction Hardware Installation TE100-P21/TEW-P21G Windows 7 Installation Instruction 1. Go to http://www.trendnet.com/downloads/ to download the Windows 7 Utility. Save the file to your desktop. 2. Right click

More information

IP PHONE SYSTEM. CooVox Series-U60 For Small and Medium Business. Quick Installation Guide. www.zycoo.com

IP PHONE SYSTEM. CooVox Series-U60 For Small and Medium Business. Quick Installation Guide. www.zycoo.com SYS WAN LAN IP PHONE SYSTEM Series-U60 For Small and Medium Business Quick Installation Guide www.zycoo.com Table of Contents 1 Package Contents 2 Hardware Installation 2.1 Safety Precautions 2.2 Installation

More information

Draper Low Voltage, Remote Control, Serial and Network Wiring Guide

Draper Low Voltage, Remote Control, Serial and Network Wiring Guide Draper Low Voltage, Remote Control, Serial and Network Wiring Guide Copyright 2007 Draper Inc. Form LV-RC-Serial-Network_Wiring07 Print ed in U.S.A. Draper Low Voltage, Remote Control, Serial and Network

More information

Power Supply and Cabling Options. SmartTrak 100/101/140

Power Supply and Cabling Options. SmartTrak 100/101/140 Power Supply and Cabling Options SmartTrak 00/0/40 2 Power Supply and Cabling Options SmartTrak 00/0/40 Table of Contents Power Supplies... Communication Cables... Accessory Options... Appendix A Communication

More information

PRO 5000 CPE 1D Quick Installation Guide

PRO 5000 CPE 1D Quick Installation Guide PRO 5000 CPE 1D Quick Installation Guide Introduction This Quick Installation Guide covers the basic installation of the PRO 5000 CPE. For more information, refer to the relevant sections in the Product

More information

NEWTECH PRO 1-2-3 KVA ONLINE UNINTERRUPTIBLE POWER SUPPLY USER MANUAL

NEWTECH PRO 1-2-3 KVA ONLINE UNINTERRUPTIBLE POWER SUPPLY USER MANUAL NEWTECH PRO 1-2-3 KVA ONLINE UNINTERRUPTIBLE POWER SUPPLY USER MANUAL info@tuncmatik.com / www.tuncmatik.com Table of Contents 1. Important Safety Warning 2 1-1. Transportation 2 1-2. Preparation 2 1-3.

More information

WxGoos-1 Climate Monitor Installation Instructions Page 1. Connections. Setting an IP Address

WxGoos-1 Climate Monitor Installation Instructions Page 1. Connections. Setting an IP Address Instructions Page 1 Connections The WxGoos-1 is a self-contained web server and requires 6vdc of power at 300ma. A center-positive 2.1 mm plug is used. There are five ports: 1. 10/100 Ethernet RJ-45 receptacle

More information

Cable Specifications. T3 Trunk Cabling APPENDIX

Cable Specifications. T3 Trunk Cabling APPENDIX APPENDIX B This appendix contains details on the MGX 8230 cabling. It includes the following sections: T3 Trunk Cabling Frame Relay Cabling DC Power Cabling AC Power Cabling Control and Clock Cabling External

More information

Dynamax Inc Copyright 2012-13

Dynamax Inc Copyright 2012-13 SAPIP Tester Cable TEST Operating Guide Troubleshoot SapIP with signal issues while in the Field or the Lab Troubles shoot cables with basic VOM tests. Section One Low Voltage SAPIP Tester - Heater Supply

More information

85Mbps Powerline HomePlug Ethernet Adapter

85Mbps Powerline HomePlug Ethernet Adapter 85Mbps Powerline HomePlug Ethernet Adapter User Manual Copyright 2008 EUSSO Technologies, Inc. All rights reserved. About This Manual The 85Mbps Powerline HomePlug Ethernet Adapter User s Manual describes

More information

Troubleshooting. Before you call for assistance

Troubleshooting. Before you call for assistance Do not open the LitePro case! Opening the case may cause electric shock! Except for the projection lamp, there are no userserviceable parts inside. If you are having problems with your LitePro, read through

More information

TREX OUTDOOR LIGHTING TROUBLESHOOTING GUIDE

TREX OUTDOOR LIGHTING TROUBLESHOOTING GUIDE TREX OUTDOOR LIGHTING TROUBLESHOOTING GUIDE DECK LIGHTING If you re experiencing a problem with any part of the Trex Deck Lighting system, please reference the troubleshooting flow charts below. Most common

More information

FlexPoint T1/E1 Copper to Fiber Line Driver

FlexPoint T1/E1 Copper to Fiber Line Driver BLACK BOX NETWORK SERVICES MT660A-MM MT661A-SM MT660A-MM-E MT661A-SM-E FlexPoint T1/E1 Copper to Fiber Line Driver CUSTOMER Order toll-free in the U.S.: Call 877-877-BBOX SUPPORT (outside U.S. call 724-746-5500)

More information

Connecting instruments serially to your computer

Connecting instruments serially to your computer Connecting instruments serially to your computer This TechNote will review how to connect instruments (GPS, Sounder, Heading Sensor ) to a computer. Important points such as electrical specification (RS-232

More information

MGM Brakes e-stroke RS-232 Diagnostic Program Users Guide

MGM Brakes e-stroke RS-232 Diagnostic Program Users Guide MGM Brakes e-stroke RS-232 Diagnostic Program Users Guide The e-stroke RS-232 Diagnostic Program may be used to acquire the following information from the e-stroke GEN 3 CCM: Current Wheel Specific Brake

More information

USB to RS-422/485 Serial Adapter

USB to RS-422/485 Serial Adapter USB to RS-422/485 Serial Adapter User Manual Ver. 2.00 All brand names and trademarks are properties of their respective owners. Contents: Chapter 1: Introduction... 3 1.1 Product Introduction... 3 1.2

More information

HyperSound System (HSS) Demo and Evaluation Systems Set-Up and Operation Guide

HyperSound System (HSS) Demo and Evaluation Systems Set-Up and Operation Guide HyperSound System (HSS) Demo and Evaluation Systems Set-Up and Operation Guide Follow this step-by-step guide for an optimal installation. Included: ü 2 HSS Emitters (Speakers) ü 2 Sets of Red & Black

More information

ICON Server box installation manual Rev. 1.1

ICON Server box installation manual Rev. 1.1 ICON Server box installation manual Rev. 1.1 Contents 1.0 About this manual... 3 2.0 Intended use... 3 2.1 European WEEE directive... 3 3.0 Installation and service instructions... 4 Server box overview...

More information

MAINTENANCE & TROUBLESHOOTING

MAINTENANCE & TROUBLESHOOTING MAINTENANCE & TROUBLESHOOTING This section describes how to: clean the lens replace the projection lamp replace the batteries in the remote use the security lock feature troubleshoot the projector Cleaning

More information

WIRELESS INTERNET TROUBLESHOOTING GUIDE. 320.834.5151 888.236.3574 www.gctel.com. Help Desk 320.834.5155

WIRELESS INTERNET TROUBLESHOOTING GUIDE. 320.834.5151 888.236.3574 www.gctel.com. Help Desk 320.834.5155 WIRELESS INTERNET TROUBLESHOOTING GUIDE 320.834.5151 888.236.3574 www.gctel.com Help Desk 320.834.5155 Table of Contents Check Physical Connection Connection Diagram - Page 1 Power Inserter - Page 2 Identify

More information

Neo-Neon. LED Vision Mesh Screen Operation Manual. LED Vision Mesh Screen. Neo-Neon International Ltd He Shan Decorative Lighting Company Limited

Neo-Neon. LED Vision Mesh Screen Operation Manual. LED Vision Mesh Screen. Neo-Neon International Ltd He Shan Decorative Lighting Company Limited Neo-Neon LED Vision Mesh Screen Operation Manual He Shan Decorative Lighting Company Limited LED Display Engineering Department 1 Contents Chapter1 Specification and Function Parameters 3 Chapeter2 Structure

More information

QSE-CI-NWK-E Control Interface

QSE-CI-NWK-E Control Interface QSE-CI-NWK-E Control Interface 369373e 1 04.05.16 The QSE-CI-NWK-E is a versatile integration access point for Lutron QS-based systems. Through either RS232 or TCP / IP over Ethernet, third-party devices

More information

Communication with BushingGard using computer USB port

Communication with BushingGard using computer USB port Communication with BushingGard using computer USB port There are two ways of communication with BushingGard through computer USB port: Direct communication between computer USB port and BushingGard USB

More information

Guide Port Interface Adapter User s Manual Model GPINT-PT

Guide Port Interface Adapter User s Manual Model GPINT-PT Guide Port Interface Adapter User s Manual Model GPINT-PT Revision 2.0 Copyright 2004-2005, Shoestring Astronomy Page 1 Introduction The Shoestring Astronomy Guide Port Interface Adapter is designed specifically

More information

MPBB1 Uploader. user manual

MPBB1 Uploader. user manual MPBB1 Uploader user manual 1997-2000 Martin Professional A/S, Denmark. All rights reserved. No part of this manual may be reproduced, in any form or by any means, without permission in writing from Martin

More information

MDI FAQ. Version 8.1.0a Page 1 of 16

MDI FAQ. Version 8.1.0a Page 1 of 16 1. Why does the MDI Explorer show MDI units blinking on and off?...3 2. Will MDI program the same modules as a TECH 2?... 3 3. How and when is a SELF TEST performed on the MDI?... 3 4. What if the MDI

More information

Business Plus Accounting Hardware Setup Guide For Windows XP

Business Plus Accounting Hardware Setup Guide For Windows XP Business Plus Accounting Hardware Setup Guide For Windows XP 1 Contents Chapter 1 - Description of Computer Ports...3 Chapter 2 - Connecting Your Touch Screen...4 Chapter 3 Setting Up Your Printers In

More information

I NTERFACE CABLE ADAPTER MODULE

I NTERFACE CABLE ADAPTER MODULE I NTERFACE CABLE ADAPTER MODULE The Interface Cable Adapter Module (ICAM) has two basic uses. First, it enables you to run shielded cable between the industrial sensor interface module (SIM) and the weather

More information

Square D Clipsal C-Bus Network Analyzer

Square D Clipsal C-Bus Network Analyzer Square D Clipsal C-Bus Network Analyzer for Use with C-Bus Wired Networks Instruction Bulletin Retain for future use. Square D Clipsal C-Bus Network Analyzer 63249-420-234A1 Instruction Bulletin 12/2006

More information

Infinity C Reference Guide

Infinity C Reference Guide 1 2! Infinity C Reference Guide Table of Contents Components... 1 Hardware Setup... 5 SmartDrive Configuration... 12 Startup... 15 Login... 16 System Configuration... 19 DICOM Setup... 20 Monitoring Status...

More information

FUSION R400 RAID USB 3.0

FUSION R400 RAID USB 3.0 FUSION R400 RAID USB 3.0 1U Rackmount 4-Drive Hardware RAID 5 SATA Storage System with USB 3.0 Interface User s Guide For Windows Contents 1 Fusion R400 RAID USB 3.0 Features 1 2 Drive Installation and

More information

ViZion Installation Guide

ViZion Installation Guide ViZion Installation Guide v2.0 1 ViZion Installation Guide Table of Contents Inventory Hardware Setup Understanding Synchronization Cable Begin by taking an inventory of the required equipment DR Unit

More information

ELECTRO-MECH SCOREBOARD CO.

ELECTRO-MECH SCOREBOARD CO. ELECTRO-MECH SCOREBOARD CO. MODEL 8650-4 HOCKEY SCOREBOARD OWNER S HANDBOOK Thank you for choosing an Electro-Mech Scoreboard for your athletic complex. We are confident that your new scoreboard will give

More information

Aquadyne TechTip TITLE: TROUBLESHOOTING PC COM PORT AND MODEM PRODUCTS AFFECTED SYMPTOMS POSSIBLE CAUSES

Aquadyne TechTip TITLE: TROUBLESHOOTING PC COM PORT AND MODEM PRODUCTS AFFECTED SYMPTOMS POSSIBLE CAUSES Aquadyne TechTip TITLE: TROUBLESHOOTING PC COM PORT AND MODEM COMMUNICATIONS WITH AN OCTOPUS. Article # 072297-1 Last reviewed: 03/25/98 Keywords: Serial Port, Modem, Polling, AquaWeb, Node Not Responding

More information

User Manual Web Operating Panel AP User Manual. General Settings, Updating and Troubleshooting

User Manual Web Operating Panel AP User Manual. General Settings, Updating and Troubleshooting User Manual Web Operating Panel AP User Manual General Settings, Updating and Troubleshooting Copyright The documentation and the software included with this product are copyrighted 2010 by Advantech Co.,

More information

IPG/7700 Hardware Manual SYSTECH. Document number 80-001099-7 Revision A

IPG/7700 Hardware Manual SYSTECH. Document number 80-001099-7 Revision A IPG/7700 Hardware Manual SYSTECH C O R P O R A T I O N Document number 80-001099-7 Revision A Created 2010, and Protected Under the U.S. Copyright Act of 1976. Copyright 2010, SYSTECH Corporation All Rights

More information

LocoNet, the Digitrax Difference

LocoNet, the Digitrax Difference LocoNet, the Digitrax Difference LocoNet is Digitrax's method of communication between LocoNet compatible devices on a model railroad layout. LocoNet Compatible devices are designed to work together on

More information

ULTIMATE SNAP-N-SEAL

ULTIMATE SNAP-N-SEAL ULTIMATE SNAP-N-SEAL F Series Compression Connectors Thomas & Betts introduces the Ultimate Snap-N-Seal Compression Connector, the newest addition to the Snap-N-Seal system. Look for the classic design

More information

MANUAL INSTALLATION + SERVICE. BACnet Commissioning Tool BCT. v100 Issue Date: 03/07/16 2016 Price Industries Limited. All rights reserved.

MANUAL INSTALLATION + SERVICE. BACnet Commissioning Tool BCT. v100 Issue Date: 03/07/16 2016 Price Industries Limited. All rights reserved. MANUAL INSTALLATION + SERVICE BACnet Commissioning Tool BCT v100 Issue Date: 03/07/16 2016 Price Industries Limited. All rights reserved. TABLE OF CONTENTS Network Overview Network Overview...1 Product

More information

USB PC Adapter V4 Configuration

USB PC Adapter V4 Configuration Programming PC adapter V4 USB PC Adapter V4 Configuration PC adapter with USB cable Flat Ribbon Cable Power Supply Unit Device Driver General The USB PC adapter V4 is used for communication between a PC

More information

IF-1 AUDIO INTERFACE ADAPTER INSTALLATION AND OPERATING INSTRUCTIONS

IF-1 AUDIO INTERFACE ADAPTER INSTALLATION AND OPERATING INSTRUCTIONS 6955 VALJEAN AVE, VAN NUYS, CA 91406 PH: (818)994-6498 / FAX: (818)994-6458 techsupport@louroe.com / www.louroe.com IF-1 AUDIO INTERFACE ADAPTER INSTALLATION AND OPERATING INSTRUCTIONS LOUROE MODEL IF-1

More information

Online UPS. PowerWalker VFI 1000R/1U

Online UPS. PowerWalker VFI 1000R/1U Online UPS PowerWalker VFI 1000R/1U Manual Uninterruptible Power Supply System Table of Contents 1. Important Safety Warning... 1 1-1. Transportation... 1 1-2. Preparation... 1 1-3. Installation... 1 1-4.

More information

Using the Communication Ports on the DG-700 and DG-500 Digital Pressure Gauges

Using the Communication Ports on the DG-700 and DG-500 Digital Pressure Gauges Using the Communication Ports on the DG-700 and DG-500 Digital Pressure Gauges 1. USB and Serial Communication Ports: Newer DG-700 and DG-500 gauges contain both a USB and a DB-9 Serial Communication Port,

More information

Internal Modem Installation with Windows 95

Internal Modem Installation with Windows 95 Internal Modem Installation with Windows 95 You will need these items from your U.S. Robotics modem box: modem phone cord Plus: a screwdriver (not included) Determining Available Resources Your U.S. Robotics

More information

Three-Phase Electric Power Distribution for Computer Data Centers

Three-Phase Electric Power Distribution for Computer Data Centers Three-hase Electric ower Distribution for Computer Data Centers WHITE AER E901 Geist January 008 Summary This paper will describe the characteristics of three-phase power and outline the advantages of

More information

Chapter 1 Installing the Gateway

Chapter 1 Installing the Gateway Chapter 1 Installing the Gateway This chapter describes how to set up the wireless voice gateway on your Local Area Network (LAN), connect to the Internet, and perform basic configuration. For information

More information

USB to RS-232/422/485 Isolated Converter. Quatech Model SSU2-400I Operation Manual

USB to RS-232/422/485 Isolated Converter. Quatech Model SSU2-400I Operation Manual USB to RS-232/422/485 Isolated Converter Quatech Model SSU2-400I Operation Manual First Edition, Jun 2008 1 Table of Contents 1. Introduction 2 2. Package checklist 3 3. Product Specification 4 4. Product

More information

RS-232 Communications Using BobCAD-CAM. RS-232 Introduction

RS-232 Communications Using BobCAD-CAM. RS-232 Introduction RS-232 Introduction Rs-232 is a method used for transferring programs to and from the CNC machine controller using a serial cable. BobCAD-CAM includes software for both sending and receiving and running

More information

Belkin High Speed Cable Modem with USB and Ethernet. User Manual

Belkin High Speed Cable Modem with USB and Ethernet. User Manual Belkin High Speed Cable Modem User Manual P74206 F5D5530-W Introduction Congratulations on your purchase of this quality Belkin product. The Belkin High-Speed Cable Modem allows you to enjoy the Internet

More information

Connecting the Console Port to a PC

Connecting the Console Port to a PC This document covers tasks associated with connecting a console port to a PC, and includes the following topics: Console (rollover) Cable and Adapters Making the physical connection Connecting using HyperTerminal

More information

Chapter 1 Connecting the Router to the Internet

Chapter 1 Connecting the Router to the Internet Chapter 1 Connecting the Router to the Internet This chapter describes how to set up the router on your Local Area Network (LAN) and connect to the Internet. It describes how to set up your wireless ADSL

More information

24-Port Channelized E1/T1 Line Card Overview

24-Port Channelized E1/T1 Line Card Overview CHAPTER -Port Channelized E/T Line Card Overview This chapter describes the Cisco series -port channelized E/T line card (referred to as the -port channelized E/T line card), and contains the following

More information

Router Setup Manual. NETGEAR, Inc Great America Parkway Santa Clara, CA USA

Router Setup Manual. NETGEAR, Inc Great America Parkway Santa Clara, CA USA NETGEAR, Inc. 4500 Great America Parkway Santa Clara, CA 95054 USA 208-10123-01 April 2007 2007 by NETGEAR, Inc. All rights reserved. Trademarks NETGEAR is a trademark of Netgear, Inc. Microsoft, Windows,

More information

Replacing Redundant AC Power Supplies in an EX4500 Ethernet Switch Without Disrupting Service

Replacing Redundant AC Power Supplies in an EX4500 Ethernet Switch Without Disrupting Service Replacing Redundant AC Power Supplies in an EX4500 Ethernet Switch Without Disrupting Service This field replacement guide provides instructions for replacing the two AC power supplies in an EX4500 Ethernet

More information

SA-9600 Surface Area Software Manual

SA-9600 Surface Area Software Manual SA-9600 Surface Area Software Manual Version 4.0 Introduction The operation and data Presentation of the SA-9600 Surface Area analyzer is performed using a Microsoft Windows based software package. The

More information

BLACK BOX. T1/E1 Link Extenders OCTOBER 2007 MT195A-T1 MT196A-E1

BLACK BOX. T1/E1 Link Extenders OCTOBER 2007 MT195A-T1 MT196A-E1 BLACK BOX NETWORK SERVICES OCTOBER 2007 MT195A-T1 MT196A-E1 T1/E1 Link Extenders Important This is a Class A device and is intended for use in a light industrial environment. It is not intended nor approved

More information

ON HOLD ANNOUNCER. Once you receive your audio announcer, check the packaging to ensure that all of the following items are enclosed:

ON HOLD ANNOUNCER. Once you receive your audio announcer, check the packaging to ensure that all of the following items are enclosed: ON HOLD ANNOUNCER The is a high quality digital on-hold announcer. It is designed to be attached to a 100BASE-T Ethernet network to receive audio production updates via the Internet. These instructions

More information

PS 155 WIRELESS INTERCOM USER MANUAL

PS 155 WIRELESS INTERCOM USER MANUAL PS 155 INTERFACE TO SIMPLEX WIRELESS INTERCOM USER MANUAL Issue 2011 ASL Intercom BV DESIGNED AND MANUFACTURED BY: ASL INTERCOM BV ZONNEBAAN 42 3542 EG UTRECHT THE NETHERLANDS PHONE: +31 (0)30 2411901

More information

OPTICAL HEADEND PLATFORM OTOHP-NMS NETWORK MONITORING MODULE INSTRUCTION MANUAL

OPTICAL HEADEND PLATFORM OTOHP-NMS NETWORK MONITORING MODULE INSTRUCTION MANUAL OPTICAL HEADEND PLATFORM OTOHP-NMS NETWORK MONITORING MODULE INSTRUCTION MANUAL Phone: (209) 586-1022 (800) 545-1022 Fax: (209) 586-1026 OTOHP-NMS Rev. X1 E-Mail: salessupport@olsontech.com www.olsontech.com

More information

High PoE Midspans NPD-6001A NPD-9501A. en Installation Manual

High PoE Midspans NPD-6001A NPD-9501A. en Installation Manual High PoE Midspans NPD-6001A NPD-9501A en Installation Manual High PoE Midspans Table of Contents en 3 Table of contents 1 Safety 4 1.1 About this Manual 4 1.2 Legal Information 4 1.3 Safety Precautions

More information

MTX-D, Oil Temperature/Pressure Gauge

MTX-D, Oil Temperature/Pressure Gauge MTX-D, Oil Temperature/Pressure Gauge 1 Mounting and Sensor Installation... 3 1.1 Mounting the Gauge... 3 1.2 Oil Temp Sensor... 3 1.3 Oil Pressure Sensor... 3 2 Wiring... 3 2.1 Main Gauge Wiring... 4

More information

Chapter 2 Installation

Chapter 2 Installation Installation Chapter 2 Installation This chapter will guide you through the installation of the Quartet Serial PCI. There are no jumpers or switches to set for this PCI Plug-n-Play board. 2-1 Hardware

More information

Table of Contents. Hardware Installation...7 Push Button Security... 8. Using the Setup Wizard...10. Configuration...11 Main... 12 Security...

Table of Contents. Hardware Installation...7 Push Button Security... 8. Using the Setup Wizard...10. Configuration...11 Main... 12 Security... Table of Contents Table of Contents Product Overview...3 Package Contents...3 System Requirements... 3 Introduction...4 Features... 4 Hardware Overview...5 LEDs... 5 Connection... 6 Hardware Installation...7

More information

Gold Cello Gold Cello Cable Kit

Gold Cello Gold Cello Cable Kit Gold Cello Gold Cello Cable Kit January 2014 (Ver. 1.101) Notice This guide is delivered subject to the following conditions and restrictions: This guide contains proprietary information belonging to Elmo

More information

Quick Installation. A Series of Intelligent Bar Code Reader with NeuroFuzzy Decoding. Quick Installation

Quick Installation. A Series of Intelligent Bar Code Reader with NeuroFuzzy Decoding. Quick Installation Quick Installation A Series of Intelligent Bar Code Reader with NeuroFuzzy Decoding This chapter intends to get your new FuzzyScan scanner working with your existing system within minutes. General instructions

More information

Actiontec Router Troubleshooting

Actiontec Router Troubleshooting Actiontec Router Troubleshooting You can use the Power, DSL, and Ethernet lights on the front panel of the Actiontec router to help diagnose home networking connectivity problems. Follow the steps below

More information

ELECTRO-MECH SCOREBOARD CO.

ELECTRO-MECH SCOREBOARD CO. ELECTRO-MECH SCOREBOARD CO. MODEL 8350-4 HOCKEY SCOREBOARD OWNER S HANDBOOK Thank you for choosing an Electro-Mech Scoreboard for your athletic complex. We are confident that your new scoreboard will give

More information

DVI DA2 and DVI DA 4 User Guide

DVI DA2 and DVI DA 4 User Guide DVI DA2 and DVI DA 4 User Guide This guide describes the installation and operation of the Extron DVI DA2 and DVI DA4 Distribution Amplifiers. Unless stated otherwise, distribution amplifier or the unit

More information

Installation Guide (No Router)

Installation Guide (No Router) Installation Guide (No Router) This installation guide will show you how to get your voip phone service working. This installation guide should be used if you have a standard DSL or cable modem and no

More information