L-Series Sealed Rocker Switches
|
|
- Chester McCarthy
- 7 years ago
- Views:
Transcription
1 L-Series Sealed Rocker Switches L-Series Sealed Rocker Switches Making the right connections has never been easier with the L-Series Rocker Switch from Carling Technologies. Not only does this innovative switch offer total design flexibility, it has set new standards for both performance and reliability. It s I certified, and able to withstand temperatures from -0 C to + C. Features include countless switch and lamp circuit combinations, LED illuminated lenses or laser etched rockers, as well as hundreds of legend choices and several accessories. Eliminates need for retooling Neatly proportioned, our L- Series fits into industry standard mounting holes of. x. and.0mm x.0mm. Integrates easily into your system You can choose from a variety of termination options, including.0 TAB QC &. TAB QC. Withstands extreme temperatures Roller pin mechanism eliminates need for lubricants, so it can withstand from - 0 C to + C. Ensures greater shock protection Welded lamp connection and one-piece internal, jumperless terminal withstand extreme shock and vibration. Maximizes your design flexibility Twelve terminals offer you an extensive range of switch and lamp circuit options, including LED or incandescent illumination. 0
2 L-Series Sealed Rocker Switches Electrical Contact VDC (MAX) resistive amps, VAC 0 amps, 0 VAC 0 amps, - VDC amps, - VDC Dielectric Strength Volts RMS between pole to pole 0 Volts RMS between live parts and accessible surfaces Insulation Resistance... 0 Megohms Initial Contact Resistance. 0 milliohms VDC Life ,000 cycles maintained, 0,000 cycles momentary at rated voltage and current Contacts /0 silver-nickel, silver tin-oxide, gold Terminals Brass or copper/silver plate / (.mm) & / (.mm) Quick Connect terminations standard. Mechanical Endurance ,000 cycles minimum hysical Lighted Seals Base Incandescent - rated 0,000 hours LED - rated 00,000 hours / life (LED is internally ballasted for voltages to VDC) Rocker, base & bracket are sealed. olyester blend rated to C with a flammability rating of 9VO. Actuator Nylon Reinforced, rated to 0 C (modular lens). Locking rocker, standard rocker & paddle. Laser etching with a polycarbonate actuator. Lens olycarbonate rated at 00 C. Front snap-in. Connector Nylon rated at C. olarized. Actuator Travel (Angular Displacement) position positions from center Environmental Environmental I, representing an index of protection as applied to electrical equipment in accordance with IEC 9, BS 90, DIN 00 0 & NFC Corrosion Resistance... MFG Class III per ASTM B- & B-, Method H, with years exposure. Operating Temperature C to + C Vibration er Mil-Std 0F, Method 0D Test Condition A 0.0 DA or 0G s 0-00 Hz. Tested with VCH connector. Test criteria - No loss of circuit during test and pre and post test contact resistance. Vibration Resonance search -0 Hz 0.0 DA ±0 G s peak Results Horizontal Axis - G s max. Random Hz 0.0 SD-Gsq/Hz 0 Hz Hz Hz Hz 0.0 No loss of circuit during test; <0µ chatter. Shock er Mil-Std 0F, Method B, Test Condition 0G s. Tested with VCH connector. Test criteria - No loss of circuit during test, pre, and post test contact resistance. Salt Spray er Mil-Std 0F, Method 0D, Test Condition A, Hrs. Thermal Shock er Mil-Std 0F, Method 0F, Test Condition A, - C to C. Test criteria - pre and post test contact resistance. Moisture Resistance.... er Mil-Std 0F, Method 0F, Test Criteria - pre and post test contact resistance. Mounting Specifications. [.0]. [.0] TEST CUT HOLE IN ACTUAL MATERIAL MOUNTING HOLE anel Thickness Range Acceptable anel Thickness.00 to. (.mm to.9mm) Recommended:.00,.0,.09,. and.
3 L Series Carling Circuit L-Series Sealed Rocker Switches E C H N - A A - Rating Termination Illumination Lamp Lamp Bracket 9 Actuator 0 Lens Style & Color Lens Style & Color Legend Legend Orientation Actuator Lens Legend SERIES L CIRCUIT Terminal Orientation osition: S D &, & Connected Terminals &, & ON NONE OFF (ON) NONE OFF ON NONE (OFF) ON NONE ON ON NONE (ON) ON OFF ON ON OFF (ON) (ON) OFF (ON) CIRCUITS WITH JUMER TERMINALS 0 (,&),(,&) OFF, OFF (,&),(,&),&,&,& ROGRESSIVE CIRCUITS & & & & & OFF (&) & & (&) & OFF (&) & (&) (&) & (OFF) & & (OFF) & & & &,& &,& &,& &,& &,& OFF, OFF (&),(&) &,& &,& (&),(&) &,& OFF,OFF (&),(&) &,& (&),(&) (&),(&) &,& (OFF),(OFF) &,& &,& (OFF),(OFF) &,& &,OFF OFF,OFF 9 &,,& &,OFF OFF,OFF 0 (&),(&) &,& (&),(&) (&),(&) &,& &,& &,& &,& &,& (&),(&) &,OFF OFF,OFF 0 &,& &,OFF OFF,& HAZARD WARNING CIRCUITS A,&, & NONE OFF,& A,&, & NONE OFF,& VDC Resistive 0A 0VAC / H, A VAC / H, No Listings B A V C 0A V ( ) - momentary S - single pole - uses terminals, &. D - double pole uses terminals, &. Terminals 9, 0, & for lamp circuit only. D 0A V E A V G 0A V H 0A V TERMINATION,,.0 (.mm) TAB (QC). (.mm) TAB (QC) ILLUMINATION Lamp #:above terminals 9 & 0 end of switch.; Lamp # above terminals & end of switch. ositive (+) and negative (-) symbols apply to LED lamps only. Lamps Illumination Type Lamp wired to Terminals S None A # Independent B # Independent + - C # Independent &# Independent + 9- D # Dependent + 9- E # Independent &# Dependent + 9- F # Independent &# Dependent + 9- G # Dependent + 9- &# Independent H # Both Independent &# (in series) # Hazard # Hazard , LAM (same coding for both selections) Selection : above terminals 0 & 9; Selection : above terminals & No lamp 0 Incandescent V V V V V LED * Red Amber Green VDC A L F VDC B M G VDC C N H VDC D J * Consult factory for daylight bright, blue/green and white LED options. Typical current draw for LED is 0ma. BRACKET COLOR Black White Gray Red Standard Bracket Rockerguard at Lamp A B C D Rockerguard at Lamp E F G H 9 ACTUATOR STYLE AND COLOR Black White Gray Red Laser Etched Rocker A B C D addle J N K M 0 & LENS STYLE AND COLOR Lens color for LEDs must be clear, white, or match color of LED. Green or blue lenses are not recommended with Neon lamps. 0 - No Actuator Z - No Lens Clear White Amber Green Red Blue - B G M T Large Transparent - C H N U Large Translucent - D J V Bar Transparent - 9 E K R W Bar Transparent A Laser Etch background color LASER ETCH, LENS OR BODY LEGEND 00 No legend this location / no actuator For legend options & codes, see page 9 of this catalog. LEGEND ORIENTATION 0 No legend (used with codes - in selection ) Orientation - vertical, lamp on top Orientation - horizontal, lamp on right Orientation - vertical, lamp on bottom Orientation - vertical, lamp on left AA- NOTES: Consult factory to verify horsepower rating for your particular circuit choice. Custom colors are available. Consult factory. Circuits 0,,, 9 when used in combination with termination codes and are not available with rating codes, C, D, G or H. Termination only available with rating codes, B, and E. Termination not available with rating code. Not available with circuits -, - and 9. AA- ACTUATOR LENS LEGEND 00 No legend this location / no actuator For legend options & codes, see page 9 of this catalog.
4 L Series Circuit L-Series Sealed Locking Rocker Switches D S W C J - M H 00 Rating Termination Illumination Lock Lamp Bracket 9 Actuator 0 Lens Lock Legend Legend Orientation SERIES L CIRCUIT Terminal Orientation ( ) - momentary S - single pole - uses terminals, &. D - double pole uses terminals, &. Terminals 9, 0, & for lamp circuit only. LAM Above terminals & No lamp 0 Incandescent V V V V V LED * Red Amber Green VDC A L F VDC B M G VDC C N H VDC D J * Consult factory for daylight bright, blue/green and white LED options. Typical current draw for LED is 0ma. osition: (lock location) S D &, & Connected Terminals &, & ON NONE OFF ON NONE ON ON OFF ON ON OFF (ON) (ON) OFF (ON) CIRCUITS WITH JUMER TERMINALS 0 (,&),(,&) OFF, OFF (,&),(,&),&,&,& ROGRESSIVE CIRCUITS & & & & & OFF (&) & & (&) & OFF (&) & (&) (&) & (OFF) & & (OFF) & & & &,& &,& &,& &,& &,& OFF, OFF (&),(&) &,& &,& (&),(&) &,& OFF,OFF (&),(&) &,& (&),(&) (&),(&) &,& (OFF),(OFF) &,& &,& (OFF),(OFF) &,& &,OFF OFF,OFF 9 &,,& &,OFF OFF,OFF 0 (&),(&) &,& (&),(&) (&),(&) &,& &,& &,& &,& &,& (&),(&) &,OFF OFF,OFF 0 &,& &,OFF OFF,& VDC Resistive 0A 0VAC / H, A VAC / H, No Listings B A V C 0A V D 0A V E A V G 0A V H 0A V TERMINATION,.0 (.mm) TAB (QC). (.mm) TAB (QC) ILLUMINATION Lamp located above terminals &, position end of switch. ositive (+) and negative (-) symbols apply to LED lamps only. Lamps Illumination Type Lamp wired to Terminals S None B # Independent + - BRACKET COLOR Black J 9 ACTUATOR STYLE AND COLOR Black Red Locking Rocker R 0 LENS STYLE AND COLOR Lens color for LEDs must be clear, white, or match color of LED. Green or blue lenses are not recommended with Neon lamps. 0 - No Actuator Z - No Lens Clear White Amber Green Red Blue - B G M T Large Transparent - C H N U Large Translucent - D J V Bar Transparent - 9 E K R W Bar Transparent FUNCTION AND COLOR Locking osition Up Down Up & Down Center Lock Color A H R Match Actuator B J S black C K T white D L V red E M W safety orange LASER ETCH, LENS OR BODY LEGEND 00 No legend this location / no actuator For legend options & codes, see page 9 of this catalog. LEGEND ORIENTATION 0 No legend (used with codes - in selection ) Orientation - vertical, lamp on bottom Orientation - horizontal, lamp on left Orientation - vertical, lamp on top Orientation - vertical, lamp on right ZAY- ZAY- ORIENTATION ORIENTATION OF ACTUATOR/LENS IN ANEL ORIENTATION ORIENTATION W Lock above terminals 0 & 9. NOTES: Consult factory to verify horsepower rating for your particular circuit choice. Custom colors are available. Consult factory. Additional lamp circuits available. Consult factory. Available only with position circuits. Termination not available with rating. Termination only available with ratings, B and E. Circuits 0,, and 9, when used in combination with termination codes is not available with rating codes, C, D, G or H. Up, Up & Down, and Center lock options will be available Q00.
5 Dimensional Specifications SHOWN WITH LASER ETCHED ACTUATOR L-Series Dimensional Specifications & Accessories SHOWN WITH ROCKER GUARD.90 [0.0].00 [.9].00 [0.]. [0.].0 [.]. [.] SHOWN WITH LARGE LENS AND ADDLE ACTUATOR.90 [0.0] SHOWN WITH BAR LENS, AND CONNECTOR.00 [.9].00 [0.]. [.] 0.0 [0.] 0 Connector Hole lug CONNECTOR LC-0 BLACK.0 TAB CONNECTOR LC-0 BLACK. TAB CONNECTOR.90 [0.0] HOLE LUG LH REMOVABLE HOLE LUG WITH NON-SERRATED WINGS LH HOLE LUG WITH SERRATED WINGS.00 [.9].00 [.0].90 [.]. [.].00 [.].0 [.].90 [0.0]. [.]
6 L-Series Accessories Mounting anel Dimensional Specifications: in. [mm] [.00] [.] R.09 MAX TY R.09 MAX TY MOUNTING ANEL TEST CUT HOLE IN ACTUAL MATERIAL [.] TEST CUT HOLE IN ACTUAL MATERIAL [.] FOR ADDITIONAL UNITS, ADD.0 [.] ER UNIT. FOR MORE THAN L-SERIES SWITCHES, ADD MIDDLE SECTION. AVAILABLE IN ANEL THICKNESSES LISTED BELOW. CONSULT FACTORY DIMENSIONS: LME.0 [.mm] LUS NUMBER OF CENTER BEZELS (LMM) X.0 [.mm] LMS MOUNTING ANEL HOLE MOUNTING ANEL OENING () UNITS MOUNTING ANEL THICKNESS.0 [.].09 [.]. [.]. [.9].00 [.].00 [.].990 [0.].00 [.]. [0.].00 [.].0 [.0] LME MOUNTING ANEL END LMM MOUNTING ANEL MIDDLE LMS MOUNTING ANEL.00 [.].00 [.].00 [.].0 [.0].00 [.].00 [.].00 [.] LM MOUNTING ANEL ANEL OENING SIZE:.90 X.0 [.mm X.mm].0 [.] LM MOUNTING ANEL ANEL OENING SIZE:.90 X.09 [.mm X 0.9mm].0 [.0].00 [.].00 [.].90 [.] LM MOUNTING ANEL ANEL OENING SIZE:.90 X. [.mm X.mm]
7 L-Series Switch Circuit Diagrams CIRCUIT CIRCUIT CIRCUIT 0
8 L-Series Switch Circuit Diagrams CIRCUIT CIRCUIT 0 A INTERNAL CONNECTION A INTERNAL CONNECTION 9 0
9 L-Series Switch Lamp Circuit Diagrams ILLUM. A B + C D LEGEND + SYMBOL DEFINITION TERMINAL LOCATION E LAM LOCATION LAM LOCATION MAINTAINED CIRCUIT MOMENTARY CIRCUIT OSITION CONNECTION F + 0 OSITION + G OSITION + 0 H INTERNAL CONNECTION INTERNAL CONNECTION + 0
10 Standard Sealed Rocker Switch Markings SYMBOL LEGEND NAME (SYMBOL MEANING) LEGEND LEGEND LEGEND LENS LENS BODY SYMBOL NAME BODY NEGATIVE OSITIVE (SYMBOL MEANING) NEGATIVE OSITIVE RUNNING LIGHTS (UNDER OWER) AA NA MA ANCHOR LIGHT LIGHT AB NB MB ANCHOR 9 0 MASTER LIGHT SWITCH AC NC MC WATER FLUSHING TA FOR OUTBOARDS HORN AD ND MD HIGH BEAM ROULSION SYSTEM TRIM TRIMMING OERATION AE NE ME LOW / DIED BEAM VENTILATION FAN OR BLOWER AF NF MF SIDE MARKER LIGHT DG 9 DF WINDSHIELD WASHER AG NG MG INTERIOR LIGHT 0 WINDSHIELD WIER AH NH MH WORK LIGHT BILGE UM AJ NJ MJ WORK LAM BILGE BLOWER AK NK MK LOADING FLOOR LAM CW 9 CY OTABLE WATER RESSURE AL NL ML ON -WIER- INT DELAY 0 ENGINE START AM ED MM ROTARY BEACON ENGINE STO AN EE MN LAM TEST DK DL DRIVE TILT TILT OERATION 0 WINDSHIELD WIER/WASHER EMERGENCY START HAZARD WARNING 9 0 U/DOWN LIFT WARM AIR BLOWER TRIM TAB TRIMMING OERATION R HORN REAR AX Y NOTE Negative lens not available on L or LD-Series. Additional Standard Markings available. Consult factory. 9
Q SERIES Ø14mm (.551") Panel Mount LED Indicators Distinctive features and specification
Distinctive features and specification Q14_VOY1609R2US Features 14mm panel mounting LED indicator 10mm colored diffused epoxy lens or 10mm water clear super bright LEDs Plated brass bezel finished in bright
More informationINDUSTRIAL CONTROLS. APEM, PO BOX 8288, HAVERHILL, MA USA 01835-0788 TOLL FREE: (877) 246-7890 FAX: (781) 245-4531 E-mail: info@apem.
INDUSTRIAL CONTROLS INDUSTRIAL CONTROLS E INDUSTRIAL CONTROLS SELECTION GUIDE Series Description Page A01 & A02 Products & Features 2 A01 & A02 Specifications 3 A01 Illuminated or non-illuminated pushbutton
More informationSignaling Lights. LH Series Surface Mount Indicators. Part Numbers. Jumbo Dome (one color) Jumbo Dome (two color)
Innovative indicators in a slim & stylish design. uces installation space. LH Series Surface Mount Indicators Key features of the LH series include: Direct mounting on surfaces such as panels, aluminum
More information2S-Series Sub-Miniature Toggle Switches
Carling Technologies S-Series Sub-Miniature Toggle Switch SS-Series Sealed Sub-Miniature Toggle Switch SM-Series Sealed Surface Mount Sub-Miniature Toggle Switch S-Series Ordering Scheme Specifications
More information2010-2011. Shortform Catalogue. Solutions for appliance & electronic applications. rocker switches. lever. switches. push. switches.
2010-2011 Solutions for appliance & electronic applications Shortform Catalogue rocker lever push vandal resistant slide door snap-action & safety rotary IEC sockets fuseholders indicators A trading name
More informationMiniature Manual Line
For application help: call 1-800-537-6945. Honeywell MICRO SWITCH Sensing and Control 67 Miniature Manual Line MML Series FEATURES Breadth of line offers complete selection of pushbuttons (including encoding
More informationGivare NC-SRS 280 och 880
Givare NC-SRS 280 och 880 Aratron AB/Nordic Control, 02 03 SRS280SEALED ROTARY SENSOR PERFORMANCE ±2 Resistance ±20% Hysteresis (repeatability) Accuracy Applied voltage maximum Resolution Output smoothness
More informationMagnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...
Magnetic and Hydraulic-Magnetic Circuit Breaker 840-G2... Description Single, two and three pole magnetic circuit breakers with trip-free mechanism and push/pull on/off manual actuation. A choice of fast
More informationThermal-Magnetic Circuit Breaker 3120-...-M1-..
Thermal-Magnetic Circuit Breaker -...-M-.. Description Single or two pole rocker switch/thermal-magnetic circuit breaker with trip-free mechanism (S-type TM CBE to EN 34). The addition of a magnetic tripping
More information1000 Series Miniature Slide Switches
Miniature Switches Features/Benefits Variety of actuators and terminations Panel mount tabs available Epoxy terminal seal compatible with bottom-wash cleaning RoHS compliant Typical Applications Test &
More informationSwitches & Pilot Devices
Key features: 21/4 (8mm) round mounting hole Compact Design Saves Space Bright and Vivid Illumination Choice of Shapes and Functions old Clad Silver Contacts for reliable low level switching Snap action
More information2 p o l e p r o t e c t i o n. S w i t c h / C i r c u i t Protector. 0. 1 t o 3 0 A m p. S e r i e s 2 4. C o u n t o n i t.
2 p o l e p r o t e c t i o n. S w i t c h / C i r c u i t Protector. 0. 1 t o 3 0 A m p. S e r i e s 2 4. C o u n t o n i t. verview F e a t u r e s. R e l i a b i l i t y. Multi-Functional to fit your
More informationUniversal MATE-N-LOK Connectors
Product Facts Pins and sockets can be intermixed in the same housing Positive polarization Rear cavity identification completely enclosed in housings Positive locking housings Insulation capability to.00
More informationCross-beam scanning system to detect slim objects. 100 mm 3.937 in
891 Object Area Sensor General terms and conditions... F-17 Related Information Glossary of terms... P.1359~ Sensor selection guide...p.831~ General precautions... P.1405 PHOTO PHOTO Conforming to EMC
More informationManual Switches Series 2 Pushbutton Switches and Indicators
BARRIER MOUNT Display screen (page 115) Mounting barrier (next page) Housing (next page) FEATURES Easy-to-assemble modules provide thousands of display/control combinations Up to 4 incandescent lamps 1,
More informationRelays High Capacity 50 Amp Mini Relays Standard Mini Relays Micro Relays Power Relays Connector Modules
CHIEF EN TERPRISES INC. M a s t e r I n t e r n a t i o n a l D i s t r i b u t o r Relays High Capacity 50 Amp Mini Relays Standard Mini Relays Micro Relays Power Relays Connector Modules M AS TER IN
More informationCat Work Lights. Make time work for you with. Cat. Work Lights
Cat Work Lights Make time work for you with Cat Work Lights When you re working against the clock, Cat Work Lights help turn night into day and increase productivity of both machines and operators in a
More informationSENSORS. Miniature Sensors - S3Z. Advanced line of miniature Asian style of photoelectric sensors. 40-300 mm background suppression
Advanced line of miniature Asian style of photoelectric sensors 4-3 background suppression.7 m proximity, 15 with narrow beam 4 m polarized retroreflective 3 m LASER through beam Standard 3-wire output
More informationColor Mark Sensor with Red or Green LED E3S-VS
Color Mark Sensor with Red or Green LED Rugged IP67 Color Mark Sensor 1 ms response time Detects a wide variety of color marks PNP or NPN output ls Light-on/ Dark-on operation, wire selectable Vertical
More informationSwitches SWITCHES SWITCHES
Switches Manufactured from Stainless Steel, Bulgin s extensive range of vandal resistant security switches are designed with a high resistance to wear and tear, corrosion and harsh use in potentially hostile
More informationSENTRON Switching and Protection Devices Air Circuit Breakers
Siemens AG 9 SENTRON Switching and rotection Devices Air Circuit reakers 5 5/ Introduction 3WL Air Circuit reakers 3WL Air Circuit reakers/ Non-Automatic Air Circuit reakers up to 63 A (AC) 5/6 General
More informationLong sensing range. Most suitable for conveyor lines and parking lot applications. 10 m 32.808 ft (Red LED)
NX SERIES Compact Multi-voltage Photoelectric Power Supply Built-in Multi-voltage photoelectric sensor usable worldwide Conforming to ow Voltage and EMC Directive Multi-voltage The NX series can operate
More informationControl and Signaling Units
Control and Signaling Table of Contents Page Specifications... 3 Constructions Characterisitics... 3 Ordering Guide... 4 Pushbutton... 5 Double Pushbutton... 6 Emergency (Mushroom Head)... 6 Selector...
More informationHow To Read A Pipe From A Sensor
Liquid Level Sensor Installation on pipes. Sensing by means electrostatic capacity and is not influenced by the color of the pipe or liquid. Available in 8 to mm dia. and to mm dia. models to enable sensing
More informationMagnetic Circuit Protectors 39. Configurations 44
SNAPAK is a snap-acting magnetic circuit protector that combines power switching and accurate, reliable circuit protection in one aesthetically pleasing package. SNAPAK Magnetic Circuit Protectors 39 combines
More informationLaserlyte-Flex Alignment System
Laserlyte-Flex Alignment System LaserLyte-Flex The LaserLyte-Flex Alignment System is a unique, interchangeable, low cost plug and play laser system. Designed specifically for aligning and positioning
More informationAdjustment functions for both span and shift have been incorporated
SENSORS FOR SERIES LED Type Wafer Alignment Sensor FX-0-F FT-F9 FD-F7 EX-F70/F60 M SH-7 FD-L4 M-DW The use of a safe LED light beam now allows for high precision detection with a resolution of 0!m (.8
More informationClear Glass Sensor. Ordering Information E3S-CR67/62. Optimum Sensor for Detecting Transparent Glass and Plastic Bottles
Clear Glass Sensor Optimum Sensor for Detecting Transparent Glass and Plastic Bottles E3S-CR67/62 Retroreflective Sensor smoothly detects 5-mm gaps. Detects transparent bottles that have a lens effect.
More informationGeneral Specifications
General Specifications Electrical Capacity (Resistive Load) ower Level (silver): 0.A @ 0V DC Logic Level (gold): 0.VA maximum @ 8V AC/DC maximum (Applicable Range 0.mA ~ 0.A @ 0mV ~ 8V) Note: Find additional
More information12.5 mm Modular Panel Potentiometers High Dielectric Strength
, D 2.5 mm Modular anel otentiometers FEATURES High dielectric strength potentiometer up to 5000 V rms 2.5 mm square single turn panel control lastic shaft and bushing Two shaft lengths and 29 terminal
More informationAZ420 MINIATURE GENERAL PURPOSE RELAY
MINIATURE GENERAL PURPOSE RELAY FEATURES Rugged construction for high reliability Life expectancy greater than 0 million operations DC coils to 11 V Power consumption as low as 2 mw per pole available
More information8146/5 Series Breaker Panelboards
8146/5 Series Breaker Panelboards DISTRIBUTION BREAKER PANELBOARDS FOR HAZARDOUS & CORROSIVE ENVIRONMENTS Breaker Panels Features: Wide variety of Flameproof branch circuit breakers for Zone 1 & Division
More informationPilot and Signaling Devices. Section 9. www.geindustrial.com Control Catalog 9-1
The GE push button offering includes a complete line of control units and stations in both full size (30 mm) push buttons and in smaller size (22 mm) devices which are designed to be used in numerous types
More informationSensing method Appearance a Connection o method Sensing distance Model NPN output PNP output Through-beam Pre-wired (see note 3) Connector.
Photoelectric Sensor with Built-in Amplifier Photoelectric Sensor with built-in amplifier is applicable to a wide variety of lines and ensures a longer sensing distance than any other model. User-friendly
More informationL304 LED PUSHBUTTON SWITCH / DISPLAY INDICATOR INDICATEUR LUMINEUX A LED / BOUTON POUSSOIR
MECHANICAL CHARACTERISTICS CARACTERISTIQUES MECANIQUE PRINCIPAL TECHNICAL CHARACTERISTICS CARACTERISTIQUES TECHNIQUES PRINCIPALES 3 possible versions - Single indicator - Momentary action pushbutton (1
More informationSolid-State Timer H3G
ASH & ALAIN INDIA PVT LTD S-100, F.I.E.E., Okhla Industrial Area, Phase-ii, New Delhi-11000(India) Tel : 011-43797575 Fax : 011-43797574 E-mail : sales@ashalain.com Solid-State Timer Low-Cost, Plug-In
More informationAppearance Type Setting distance Sensing area Model Remarks Camera with lighting. 34mm to 49mm 5mm x 4.9mm to 9mm x 8.
ZFX-C/25-CD Easy Vision Touch, Connect & Go Easy vision intuitive teach & go user interfaces Live built-in LCD touch monitors for setup and iediate feedback Counication centralized setup & inspection via
More informationAppearance Type Setting distance Sensing area Model Remarks Camera with lighting. 34mm to 49mm 5mm x 4.9mm to 9mm x 8.
ZFX-C10/15-CD Easy Vision Touch, Connect & Go Easy vision intuitive teach & go user interfaces Live built-in LCD touch monitors for setup and iediate feedback Counication centralized setup & inspection
More informationAbsolute Rotary Encoder E6CP
Absolute Rotary Encoder Absolute Rotary Encoders with Gray Code Output Gray code output decreases output errors Lightweight plastic housing Used with Omron s H8PS Cam Positioner, this encoder detects the
More informationAP/UP, AP/MIL Series. Magnetic Circuit Protectors
AP/UP, AP/MIL Series Magnetic Circuit Protectors Introduction Poles Configurations Operating Characteristics Delay Curves Specifications Decision Tables 71 72 75 76 77 78 79 AP/UP, AP/MIL Series Hydraulic
More informationWiring diagrams for luminous 1P 1-way switches with 110 V~ or 250 V~ signalling units
Devices Switches - TECHICA CHARACTERISTICS Scope Switching on and off of ohm-inductive loads: lighting circuits: - lighting fittings (luminaires) for use incandescent lamps - lighting fittings (luminaires)
More information12S, 14S, 15S Series. Time Delay Relays and Sequencers. Time Delay Relays and Sequencers. Features and Benefits. Switch Actions and Configurations
12S, 14S, 15S Series Time Delay Relays and Sequencers Time Delay Relays and Sequencers The Therm-O-Disc type 12S, 14S and 15S series time delay relays and sequencers are field-proven devices for controlling
More informationSMA Interface Mating Dimensions (Per MIL-STD-348)
SMA Series SMA 6 SMA Interface Mating Dimensions (Per MIL-STD-348) SMA Interface Dimensions MALE Inches/Millimeters 3 Minimum Nominal Maximum LTR in. mm in. mm in. mm A.250 6.35.263 6.68.. B.1790 4.55.1808
More informationSAF-T-LINER MVP-EF PARTS MANUAL. Electrical Section. Page 7-1. Electrical 10/96
Electrical Page 7-1 Switch Cabinet Page 7-2 Electrical Switch Cabinet Item Part Num. Number Qty. Description Notes 1 52002053 1 Cabinet - Switch, Assembly For Thomas Forward Control 2 68000868 1 Insulator
More informationWE-350 Series ¼ Turn Electric Actuator
WE-350 Series ¼ Turn Electric Actuator Operation and Installation Manual Pg 1 (Rev. 020113) Table of Contents 1.0 General 1.1 Pre-Installation Inspection 1.2 Storage 1.3 Features & General Information
More informationCOAXICON Contacts. RF Coax Connectors. Product Facts
COXICON Contacts Product Facts Tyco Electronics provides a variety of contacts for coaxial connectors Contacts are available in a range of sizes that may be used with the various types of coaxial cable
More informationEXLUX ECOLUX C-LUX LIGHTING. Explosion Protected Fluorescent Lighting Fixtures for Hazardous and Corrosive Applications
EXLUX ECOLUX C-LUX LIGHTING 6000 6008 6400 6408 6600 6608 6500 Explosion Protected Fluorescent Lighting Fixtures for Hazardous and Corrosive Applications Features: Electronic Ballasts For Fluorescent Bipin
More informationPOWER ROCKER SWITCH UL, CSA, VDE, TÜV, ÖVE, KEMA, SEMKO, NEMKO, DEMKO, FIMKO, SEV UL, CSA, VDE, TÜV, SEMKO, NEMKO, DEMKO, FIMKO, SEV, KEMA, ÖVE
POWER ROCKER SWITCH SWITCHES AJ8 switch standard actuator AJ8 switch Wide actuator RoHS Directive compatibility information http://www.nais-e.com/ FEATURES 1. Power rocker switches for safety requirements.
More informationMureva Assembly surface mounted wiring devices
1.0 Waterproof Assembly surface Switches P124543 P124547 External dimensions : 72 x 72 x 47 mm.. Assembly surface rockers become illuminated using bulbs and indicators in option. They can carry a label
More informationOPL BASIC. Dosing System for Professional Laundry machines. Contents
OPL BASIC Dosing System for Professional Laundry machines Contents 1 Getting Started. Page 2 2 Installation. Page 4 3 Set Up & Operation. Page 8 4 Maintenance & Accessories. Page 10 5 Troubleshooting Page
More informationPD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description
Photoelectrics, Background Suppression reflective with IR light Main features Description The PD30ET... stainless steel sensors are built with high-quality materials and designed for harsh environments.
More informationUTS discrete wire sealing
Technical characteristics Mechanical Durability: 250 matings & unmatings Vibration resistance: Sinusoidal vibrations per CEI 605-4 - from 10 to 2000 Hz Thermal shock: 5 cycles 30 min. from -40 C to 105
More informationsensors Miniature Sensors - S100 The universal miniature photoelectric sensor
Miniature Sensors - S1 The universal miniature photoelectric sensor Two threaded front mounting holes Two slotted rear mounting holes Anti-tampering sensor (no adjustment) Standard optic functions and
More informationC ole s quality Open Frame Instrument Rotary Switch provides low
OPEN FRAME series C ole s quality Open Frame Instrument Rotary Switch provides low contact resistance (.005W), very high contact reliability, smooth action with positive positioning, precision design,
More information600H and 600NH series
600H and 600NH series Toggle switches - high amperage Distinctive features and specifications Construction Terminal and contact support are manufactured from a single piece of metal. The contacts are resistance-welded
More information.093 [2.36] Commercial Pin and Socket Connectors
Product Facts Polarized Cavity identification Low contact-mating force Dual locking lances Detent and positive locking Contacts available in brass and phosphor bronze with tin and gold plating Panel mounting
More informationSERIES 1800 - SINGLE POLE AND DOUBLE POLE ROCKER SWITCHES UP TO 12 (4) A 250 V~ AND 8 (8) A 250 V~
SERIES 1800 - SINGLE POLE AND DOUBLE POLE ROCKER SWITCHES UP TO 12 (4) A 250 V~ AND 8 (8) A 250 V~ PRODUCT ADVANTAGES Switching principle with long life endurance due to a low friction contact system (ball),
More informationSlimline Plus. Catalogue No. R6
Slimline Plus Catalogue No. R6 slimline plus Stylish Robust Ease of installation Affordable For over 55 years, MK Electric has been a household name throughout the Asia Pacific region, trusted and respected,
More informationE3Z. Ordering Information. Photoelectric Sensor with Built-in Amplifier. Compact Sensor Offers Long Sensing Distance and Superior Noise-Immunity
Photoelectric Sensor with Built-in Amplifier Compact Sensor Offers Long Sensing Distance and Superior Noise-Immunity H Photo-IC provides long sensing distance: 15 m for through-beam, 4 m for retroreflective,
More informationHOW TO READ THE WIRING DIAGRAMS
A-1 HOW TO READ THE WIRING DIAGRAMS CONTENTS COMPOSITION AND CONTENTS OF WIRING DIAGRAMS... 2 HOW TO READ CONFIGURATION DIAGRAMS... 3 MARKING FOR CONNECTOR EARTHING... 6 WIRE COLOUR CODES... 9 ABBREVIATION
More informationOutdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points
Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points Features SELV Compliant No Detection Passive Injector Gigabit Compatible Full Protection
More informationFASTON Terminals and Connectors
Introduction Product Facts Straight, right-angle and receptacle-tab combinations available Receptacles available for 6.3 mm, 4.8 mm and 2.8 mm tab size (.250,.187 and.110 Series) Receptacles mate with
More informationTSn SERIES Surge Protective Device
Page: 1 of 8 TSn SERIES Surge Protective Installation & Operation Manual 3621 Saunders Avenue www.systems.us Ph 804.355.1100 Richmond, VA 23227 4354 Sales@Systems.us Fax 804.355.8900 Page: 2 of 8 Quick
More informationD2SW-P. Sealed Subminiature Basic Switch. Ordering Information
Sealed Subminiature Basic Switch Sealed Basic Switch with Simplified Construction, Mounting Compatible with SS and D2SW Series. Sealing by using rubber packing means the switch can be used in dust-proof
More information5W HI-POWER LED SPECIFICATION
5W HI-POWER LED SPECIFICATION HPG8b-495xWHCx Drawn by Checked by Approved by RoHS Conformity DATE:2013/4/9 REV:A HUEY JANN High Power 5W LED is made of GaInN chips with precise package technique which
More informationLED LEONARDO 120 W. LED Fresnel SPOTLIGHT White light, either Tungsten or Daylight balanced Correlated Color Temperature
LED LEONARDO 120 W LED Fresnel SPOTLIGHT White light, either Tungsten or Daylight balanced Correlated Color Temperature OVERVIEW The LED LEONARDO 120W is a highly efficient Fresnel lens spotlight using
More informationCircuit Breakers. NRC Series. NRC Series. 900 www.idec.com
Switches & Pilot Lights Display Lights NRC series circuit breakers offer circuit protection which is far superior to using fuses in applications containing relay circuits, motor circuits, heater circuits,
More information1/2" (12.7 mm) Conductive Plastic and Cermet Potentiometer
1/2" (12.7 mm) Conductive Plastic and Cermet Potentiometer FEATURES Robust construction High rotational life (50 000 cycles) Up to three sections PC support plates Rotary switches and solder lugs terminals
More informationAP Series Industrial Pushbutton Switch
P Series Features/Benefits IP67 sealed 1,000,000 life cycle Illumination / non-illumination Multiple colored caps Threaded or snap-in mounting Caps available separately RoHS compliant Typical pplications
More informationINDICATOR LAMPS & LED REPLACEMENT LAMPS
INDICATOR LAMPS & LED REPLACEMENT LAMPS Neon indicators (internal resistor) 120VAC 55-452-0 Red lens 120VAC 55-453-0 Amber lens 120VAC 55-455-0 Green lens 120VAC Neon indicators (internal resistor) 120VAC
More informationPSU-U-24V/AC-6A/10/FTA-TR-MC PSAC 0624
PSU-U-24V/AC-6A/10/FTA-TR-MC PSAC 0624 v.1.0 AC/AC power supply unit Edition: 1 from 24 th October 2008 Supercedes edition: ---------- 10062009 CONTENTS: 1. Technical description. 1.1. General description
More informationTOKISTAR. Cable Lighting TOKISTAR LIGHTING
TOKISTAR Cable Lighting TOKISTAR LIGHTING Cable Lighting Systems T okistar s innovative and versatile Cable Lighting Systems provide uniform soft illumination. Their compact profiles are easily incorporated
More informationRoof Top Air Conditioner INSTALLATION AND OPERATING INSTRUCTIONS
Roof Top Air Conditioner INSTALLATION AND OPERATING INSTRUCTIONS Ducted System RECORD THIS UNIT INFORMATION FOR FUTURE REFERENCE: Model Number: Serial Number: Date Purchased: This manual must be read and
More informationCompliant Terminal Technology Summary Test Report
Engineering Report ER04100 October 5th, 2004 Revision A Copyright Autosplice Inc., September 2004 Table of Contents Summary Overview 3 Compliant Terminal Specifications 3 Test Plan 4 Test Conditions 4
More informationONE OF THE SMALLEST SNAP-ACTION SWITCHES IN THE WORLD. FEATURES Superminiature type, light-weight snap action switch PC board terminal type (0.
ONE OF THE SMALLEST SNAP-ACTION SWITCHES IN THE WORLD SWITCHES FEATURES Superminiature type, light-weight snap action switch PC board terminal type (0.2g) Solder terminal type with mounting holes (0.3g)
More informationHigh-ohmic/high-voltage resistors
FEATURES These resistors meet the safety requirements of: UL1676 (range 510 kω to 11 MΩ) EN60065 BS60065 (U.K.) NFC 92-130 (France) VDE 0860 (Germany) High pulse loading capability Small size. APPLICATIONS
More informationSENSORS. Fiber Optic Sensors - S70. Advanced fiber optic amplifiers for high speed and low contrast applications
Fiber Optic Sensors - S7 Advanced fiber optic amplifiers for high speed and low contrast applications DIN rail mountable models with dual digital displays speed models: 2 μs...5 ms Super high speed models:
More information12VDC MAGNETIC LED DIMMABLE POWER SUPPLIES SPEC SHEET DIGEST
12VDC MAGNETIC ED DIMMABE POER SUPPIES SPEC SEET DIGEST TM-30-DIM TM-50-DIM T-60-DIM TM100-DIM TM200-DIM TM300-DIM iring Diagram for TM-50-DIM and TM-100-DIM ED 12VDC MAGNETIC DIMMABE 30 POER SUPPY Smallest
More informationGeneral Specifications
Series M eneral Specifications Miniature Supplement ccessories Indicators Touch Tilt Tactiles Slides Rotaries Keylocks Programmable Illuminated PB Pushbuttons Rockers Electrical apacity (Resistive Load)
More informationPRODUCT GUIDE. SL Medium Voltage IEC Vacuum Contactors
PRODUCT GUIDE SL Medium Voltage IEC Vacuum Contactors Table of Contents 1 Overview Introduction....................................................2 Features........................................................2
More informationEE-SPY801/802. Photomicrosensors for detecting wafer-carrier mounting. Wafer-carrier Mounting Photomicrosensors. Ordering Information.
Wafer-carrier Mounting Photomicrosensors EE-SPY1/ CSM_EE-SPY1 DS_E_3_ Photomicrosensors for detecting wafer-carrier mounting. The mounting position is set with a pedestal. The contact surface with the
More informationOrdering Information. Cylindrical Proximity Sensor E2E/E2E2
Cylindrical Sensor E2E/E2E2 A New Series of Easy-to-use and Tough E2E/E2E2 Models Long-size E2E2 Sensor Conforms to CENELEC Ideal for a variety of applications. With a metal connector that can be tightened
More information7 Lighting Technology
7 Lighting Technology Series HS6145 For use in Zone 1 and Zone 2 Comply with requirements of Fire Department standard DIN 14 462 Battery state display Deep discharge protection Open circuit monitor Light
More informationSwitches and Indicators. Swisstac
Switches and Indicators Switches and Indicators Index Series Description Page 583 Product Assembly Page 584 Mounting Instruction Page 585 Product Range - pushbuttons for standard mounting - pushbuttons
More information1000 Series Miniature Slide Switches
Miniature Switches Features/Benefits Variety of actuators and terminations Panel mount tabs available Epoxy terminal seal compatible with bottom-wash cleaning RoHS compliant Typical Applications Test &
More informationPressure Switch for gas and air
Switch for gas and air GAO-A4 GMH-A4 GML-A4 UL Listed UL 353 File # MH 16628 CSA Certified CSA C22.2 No. LR 53222 Certification file # 201527 FM Approved Class 3510, 3530 File # J.I. 1Y919.AF Commonwealth
More informationKnow-how makes the difference. Electrical Actuators
Know-how makes the difference Electrical Actuators With Dansk Ventil Center as your business partner, you are always guaranteed a wide and well sorted product range and a unique technical know-how Product
More informationHP ProLiant DL380 G6 Carrier-Grade Server Read Before Install
HP ProLiant DL380 G6 Carrier-Grade Server Read Before Install Carrier-Grade Instructions HP Part Number: AM275-9001A Published: July 2012 Edition: 3 Copyright 2009, 2012 Hewlett-Packard Development Company,
More informationALARM ANNUNCIATOR ME - 3010 INSTRUCTION MANUAL
ALARM ANNUNCIATOR ME - 3010 INSTRUCTION MANUAL INTRODUCTION... 2.. TECHNICAL DATA... 3 ACCESSORIES... 5. INSTALLATION... 7 OPERATION... 12. TECHNICAL INFORMATION... 13 MAINTENANCE... 14. CONFIGURATIONS...
More informationMiniature High-Resolution Registration Mark Sensor White LED AUTOSET Remote Setup Option
REGISTRATION MARK SENSORS MARK EYE PRO 2 Miniature High-Resolution Registration Mark Sensor White LED AUTOSET Remote Setup Option Registration Mark Photoelectric Sensors 2-115 High-Resolution Registration
More informationOperating Instructions. Room temperature controller
Operating Instructions 1. Area of application The room temperature controller is used to regulate the temperature in closed rooms such as flats, schools, function suites, workshops, etc. Safety instructions
More informationSeries 8146/5-V37 and Series 8150/5-V37
www.stahl.de > Clear assignment safe technology easy installation > Intelligent structure only one rotary actuator for frequency-controlled drives ) 20 ms leading auxiliary contact for safe motor disconnection
More information400 Series - Mini USB Buccaneer
IP68 Sealed IP68 rated USB V2.0 performance Plug and play capability Shielded system Overmoulded cables Screw coupling PCB versions Dust and waterproof to EN60529 Data rates up to 480Mbs Hot pluggable,
More informationDigi-Motor Installation Guide
Digi-Motor Installation Guide Installation Video...located at marsdelivers.com Digi-Motor Installation Guide Digi-Motor For technical assistance with your Azure Digi-Motor, call the MARS technical support
More informationBODY ELECTRICAL MAZDA
BODY ELECTRICAL ASSIGNMENT WORKSHEETS Version 1.3 MAZDA ELECTRICAL WIRING DIAGRAM WORKBOOK http://www.autoshop101.com Developed by Kevin R. Sullivan All rights reserved. MAZDA Table of Contents Wiring
More informationSubaru Reference. This reference contains the following information: connector pinouts. connector pinouts
Subject: Source: 1993 2010 Impreza, WRX, and Sti and 2002 07 Outback Sport ABS wiring diagrams, harness routing, and connector locations and pinouts Subaru service manuals This reference contains the following
More informationTechnical. Specifications. fischer Rugged Flash Drive. New. Rugged Solution for Safe Data Storage in Harsh Environment
fischer Rugged Flash Drive New Rugged Solution for Safe Data Storage in Harsh Environment Headquarters Fischer Connectors SA Ch. du Glapin 20 1162 Saint-Prex Switzerland Phone +41 21 800 95 95 mail@fischerconnectors.ch
More informationVIBRATION MONITORING OF FANS INSTALLED IN ROAD TUNNELS
VIBRATION MONITORING OF FANS INSTALLED IN ROAD TUNNELS CEMB SPA Via Risorgimento, 9 Mandello del Lario (Lc), Italy stm@cemb.com www.cemb.com INSTRUMENT FOR MONITORING VIBRATIONS OF FANS INSTALLED IN ROAD
More informationLOADING DOCK EQUIPMENT. A. Section 03100 - Concrete Forms and Accessories: Placement of anchors into concrete.
LOADING DOCK EQUIPMENT PART 1 GENERAL 1.1 SECTION INCLUDES A. Loading dock equipment of the following types: 1. Dock lifts. 2. Control stations. 1.2 RELATED SECTIONS A. Section 03100 - Concrete Forms and
More informationLM10. Micro Laser Displacement Sensor. The LM10 makes laser sensors super easy to use! New circuitry lowers costs
857 Micro Sensor General terms and conditions... P.1 Related Information Glossary of terms / General precautions... P.1019 / P.1027 Sensor selection guide... P.11~ / P.833~ About laser beam... P.1025 ~
More information