EI 54. Printed-Circuit-Board transformers Output Power: 12.0 VA 22.0 VA. Type cast housing K with 2 fixing straps

Size: px
Start display at page:

Download "EI 54. Printed-Circuit-Board transformers Output Power: 12.0 VA 22.0 VA. Type cast housing K with 2 fixing straps"

Transcription

1 Output Power: 12.0 VA 22.0 VA EI 54 Type cast housing K with 2 fixing straps Type cast housing SV for upright mounting EI 54 Page 6 02/2013

2 Output Power: 17.0 VA 35.0 VA EI 60 DIN EN VDE VDE-Mark for Glow-Wire-Test DIN EN VDE / according to REACH regulation - according to RoHs regulation UL UL on request UL UL E98173 C22.2 CSA on request Output Power up to 35.0 VA Non short-circuit-proof at temperature class Standard type cast housing KK Excellent temperature luctuation resistance properties High electrical safety and long service-life features High voltage resistance Self-extinguishing cast housing and sealing material Per item tested quality with certiicate Protection extern secondary by: Micro fuse according to IEC 127 or PTC resistance pins type cast housing KK with 4 ixing straps (only connected pins are present) 2.) double voltage bridge: , double current bridge: / Output Power Height (h) Weight Packaging unit BV EI /16.0 mm* 17.0 VA 40.5 ± 0.5 mm kg 18 pieces BV EI /21.0 mm 20.0 VA 44.7 ± 0.5 mm kg 18 pieces BV EI /25.5 mm 28.0 VA 49.2 ± 0.5 mm kg 18 pieces BV EI /30.5 mm 30.0 VA 54.2 ± 0.5 mm kg 18 pieces BV EI /35.0 mm 35.0 VA 57.3 ± 0.5 mm kg 18 pieces * only type cast housing 0 02/2013 EI 60 Page 1

3 Output Power: up to 28.0 VA EI VA BV EI / 16.0 mm BV EI x x BV EI x / x BV EI x x BV EI x / x BV EI x x BV EI x / x BV EI x x BV EI x / x BV EI x x BV EI x / x BV EI x x BV EI x / x BV EI x x VA BV EI / 21.0 mm BV EI x x BV EI x / x BV EI x x BV EI x / x BV EI x x BV EI x / x BV EI x x BV EI x / x BV EI x x BV EI x / x BV EI x x BV EI x / x BV EI x x VA BV EI / 25.5 mm BV EI x x BV EI x / x BV EI x x BV EI x / x BV EI x x BV EI x / x BV EI x x BV EI x / x BV EI x x BV EI x / x BV EI x x BV EI x / x BV EI x x /2013 EI 60 Page 3

4 Output Power: up to 35.0 VA EI VA BV EI / 30.5 mm BV EI x x BV EI x / x BV EI x x BV EI x / x BV EI x x BV EI x / x BV EI x x BV EI x / x BV EI x x BV EI x / x BV EI x x BV EI x / x BV EI x x VA BV EI / 35.0 mm BV EI x x BV EI x / x BV EI x x BV EI x / x BV EI x x BV EI x / x BV EI x x BV EI x / x BV EI x x BV EI x / x BV EI x x BV EI x / x BV EI x x EI 60 Page 4 02/2013

5 Output Power: 17.0 VA 35.0 VA EI 60 DIN EN VDE on request VDE-Mark for Glow-Wire-Test DIN EN VDE on request UL UL on request UL UL on request Individual version! Parallel to the cataloged EI 60 series transformers, HAHN also produces other variants, e.g. with integrated thermo fuse or thermo switch, other housing-, fixingand connective options as well as non-encapsulated transformers. - according to REACH regulation - according to RoHs regulation C22.2 CSA on request Type cast housing 0 Type cast housing 0 with fixing band 02/2013 EI 60 Page 5

6 Output Power: 17.0 VA 35.0 VA EI 60 Type cast housing SV with fixing band EI 60 Page 6 02/2013

7 Output Power: 17.0 VA 50.0 VA EI 66 DIN EN VDE VDE-Mark for Glow-Wire-Test DIN EN VDE / according to REACH regulation - according to RoHs regulation UL UL on request UL UL on request C22.2 CSA Output Power up to 50.0 VA Non short-circuit-proof at temperature class Standard type cast housing KK Excellent temperature luctuation resistance properties High electrical safety and long service-life features High voltage resistance Self-extinguishing cast housing and sealing material Per item tested quality with certiicate Protection extern secondary by: Micro fuse according to IEC 127 or PTC resistance pins type cast housing KK with 4 ixing straps (present only connected pins) 2.) double voltage bridge: , double current bridge: / Output Power Height (h) Weight Packaging unit BV EI /12.0 mm 17.0 VA 38.5 ± 0.5 mm kg 16 pieces BV EI /18.0 mm 25.0 VA 44.5 ± 0.5 mm kg 16 pieces BV EI /23.0 mm 33.0 VA 48.5 ± 0.5 mm kg 16 pieces BV EI /30.0 mm 44.0 VA 55.8 ± 0.5 mm kg 16 pieces BV EI /34.8 mm 47.0 VA 60.2 ± 0.5 mm kg 16 pieces BV EI /40.0 mm 50.0 VA 66.5 ± 0.5 mm kg 16 pieces 02/2013 EI 66 Page 1

8 Output Power: up to 33.0 VA EI VA BV EI / 12.0 mm BV EI x x BV EI x / x BV EI x x BV EI x / x BV EI x x BV EI x / x BV EI x x BV EI x / x BV EI x x BV EI x / x BV EI x x BV EI x / x BV EI x x VA BV EI / 18.0 mm BV EI x x BV EI x / x BV EI x x BV EI x / x BV EI x x BV EI x / x BV EI x x BV EI x / x BV EI x x BV EI x / x BV EI x x BV EI x / x BV EI x x VA BV EI / 23.0 mm BV EI x x BV EI x / x BV EI x x BV EI x / x BV EI x x BV EI x / x BV EI x x BV EI x / x BV EI x x BV EI x / x BV EI x x BV EI x / x BV EI x x /2013 EI 66 Page 3

9 Output Power: up to 50.0 VA EI VA BV EI / 30.0 mm BV EI x x BV EI x / x BV EI x x BV EI x / x BV EI x x BV EI x / x BV EI x x BV EI x / x BV EI x x BV EI x / x BV EI x x BV EI x / x BV EI x x VA BV EI / 34.8 mm BV EI x x BV EI x / x BV EI x x BV EI x / x BV EI x x BV EI x / x BV EI x x BV EI x / x BV EI x x BV EI x / x BV EI x x BV EI x / x BV EI x x VA BV EI / 40.0 mm BV EI x x BV EI x / x BV EI x x BV EI x / x BV EI x x BV EI x / x BV EI x x BV EI x / x BV EI x x BV EI x / x BV EI x x BV EI x / x BV EI x x EI 66 Page 4 02/2013

10 Output Power: 17.0 VA 50.0 VA EI 66 DIN EN VDE on request VDE-Mark for Glow-Wire-Test DIN EN VDE on request UL UL on request Individual version! Parallel to the cataloged EI 66 series transformers, HAHN also produces other variants, e.g. with integrated thermo fuse or thermo switch, other housing-, fixing- and connective options as well as non-encapsulated transformers. - according to REACH regulation - according to RoHs regulation UL UL on request C22.2 CSA on request Type cast housing 0 Type cast housing 0 with fixing band 02/2013 EI 66 Page 5

11 Output Power: 17.0 VA 50.0 VA EI 66 Type cast housing SV for upright mounting EI 66 Page 6 02/2013

Catalog HAHN QUALITY. Performance that builds trust.

Catalog HAHN QUALITY. Performance that builds trust. Catalog HAHN QUALITY Performance that builds trust. Quality will remain after the price has been forgotten. HAHN QUALITY Performance that builds trust. 2 At first we can achieve the right potential from

More information

PCB transformers. Short circuit proof PCB transformer VB. General Data. Advantages. Applications. Circuit diagram. Standards & 1 Certifications W v

PCB transformers. Short circuit proof PCB transformer VB. General Data. Advantages. Applications. Circuit diagram. Standards & 1 Certifications W v Short circuit PCB transformer General Data Rated input 230 Vac Rated output 6-2 x 24 Vac Rated power 0.35-3.2 VA Insulation class B Maximum ambient temperature 70 C Efficiency up to 58 % Degree of protection

More information

DEK-REL- 24/1/SEN. Extract from the online catalog. Order No.: 2964050

DEK-REL- 24/1/SEN. Extract from the online catalog. Order No.: 2964050 Extract from the online catalog DEK-REL- 24/1/SEN Order No.: 2964050 Relay terminal block for sensor, with soldered-in miniature relays, contact (AgNi+Au): small to medium loads, 1 N/O contact, input voltage

More information

Actuator-Sensor-Interface

Actuator-Sensor-Interface Selection and ordering data Design Order No. Price Pack 3RX9 307-0AA00 3RX9 307-1AA00 4FD5 213-0AA10-1A 3RX9 305-1AA00 3RX9 306-1AA00 Single output IP 65 current 2.4 A Rated input voltage DC 24 V current

More information

Component acceptability for CE product Safety

Component acceptability for CE product Safety Component acceptability for CE product Safety Technical Note 37 The following component status table applies to the general approval of electrical or electronic safety critical components (e.g. transformers,

More information

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: 2868567. DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: 2868567. DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase Extract from the online catalog STEP-PS/1AC/12DC/1.5 Order No.: 2868567 DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase Commercial data EAN 4046356292924 Pack 1 pcs. Customs tariff

More information

RM17TE 183...528 V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

RM17TE 183...528 V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC Characteristics multifunction control relay RM17-TE - range 183..528 V AC Complementary Reset time Maximum switching voltage Minimum switching current Maximum switching current [Us] rated supply voltage

More information

RM35UA13MW. range 15..600 V. Main. Product or component type. Relay monitored parameters

RM35UA13MW. range 15..600 V. Main. Product or component type. Relay monitored parameters Characteristics multifunction voltage control relay RM35-U - range 15..600 V Complementary Reset time Maximum switching voltage [Us] rated supply voltage Supply voltage limits Power consumption in W Main

More information

Type: DILM32 10(24V50HZ) Article No.: 277247

Type: DILM32 10(24V50HZ) Article No.: 277247 Type: DILM32 10(24V50HZ) Article No.: 277247 Ordering information Rated operational current AC 3 400 V I e A 32 Max. rating for three phase motors, 50 60 Hz AC 3 230 V Max. rating for three phase motors,

More information

Type: DILM9 10(24VDC) Article No.: 276705

Type: DILM9 10(24VDC) Article No.: 276705 Type: DILM9 10(24VDC) Article No.: 276705 Ordering information Rated operational current AC 3 400 V I e A 9 Max. rating for three phase motors, 50 60 Hz AC 3 230 V Max. rating for three phase motors, 50

More information

Manual Motor Starter MS 116 up to 16 A Technical Data

Manual Motor Starter MS 116 up to 16 A Technical Data Manual Motor Starter MS 116 up to 16 A Technical Data Type MS 116 Standards: Major International IEC 60 947-4-1 / IEC 60 947-2 and European Standards EN 60 947-4-1 / EN 60 947-2 Approvals, Certificates

More information

47000 SERIES - ELECTRONIC TRANSFORMERS

47000 SERIES - ELECTRONIC TRANSFORMERS 7000 SERIES - ELECTRONIC TRANSFORMERS MYRRA encapsulated electronic transformers are Switched Mode Power Supplies based on Flyback topology. They constitute an interesting alternative to the traditional

More information

Type: DILM50(230V50HZ,240V60HZ) Article No.: 277830

Type: DILM50(230V50HZ,240V60HZ) Article No.: 277830 Type: DILM50(230V50HZ,240V60HZ) Article No.: 277830 Ordering information Rated operational current AC 3 400 V I e A 50 Max. rating for three phase motors, 50 60 Hz AC 3 230 V Max. rating for three phase

More information

RM4TG20 three-phase network control relay RM4-T - range 200..500 V

RM4TG20 three-phase network control relay RM4-T - range 200..500 V Characteristics three-phase network control relay RM4-T - range 200..500 V Complementary [Us] rated supply voltage Output contacts Setting accuracy of time delay Delay at power up Measuring cycle Marking

More information

2 POLES - 5A LOW PROFILE TYPE

2 POLES - 5A LOW PROFILE TYPE FTR-K1 SERIES POWER RELAY 2 POLES - 5A LOW PROFILE TYPE FTR-F1 Series FEATURES Low profile (height: 16.5mm) DPST/DPDT 5A, TV-3 rating available High insulation (due to its reinforced insulation construction)

More information

Electro-pneumatic control valves

Electro-pneumatic control valves Electropneumatic control valves 7 Miniature solenoid valves for alternating current Conform to the Low Voltage Directive or mounting on subbase or footprint in accordance with CNOMO recoendation E 066120N

More information

1 POLE - 16A 80A Inrush type. (b) Contact configuration A : 1 form A (SPST-NO) C : 1 form C (SPDT) (standard type "K" only)

1 POLE - 16A 80A Inrush type. (b) Contact configuration A : 1 form A (SPST-NO) C : 1 form C (SPDT) (standard type K only) FTR-K1 SERIES POWER RELAY 1 POLE - 16A 80A Inrush type FTR-K1 Series FEATURES Peak 80A inrush current (1 form A type) Low profile (height: 15.7mm) HIGH INSULATION Insulation distance (between coil and

More information

PHOENIX CONTACT - 2012-12-14. Features

PHOENIX CONTACT - 2012-12-14. Features Electronic monitoring relay for phase sequence, phase failure, and asymmetry monitoring Data sheet 101748_en_03 1 Description PHOEIX COTACT - 2012-12-14 Features Increasingly higher demands are being placed

More information

RoHS APPROVAL SHEET. ituner 12V/6.6A SERIES NO. (E17) EA10953A. ( ) Edac Power Electronics (Suzhou) Co., Ltd. 59 No.59, Chang Sheng Road, Sheng Pu,

RoHS APPROVAL SHEET. ituner 12V/6.6A SERIES NO. (E17) EA10953A. ( ) Edac Power Electronics (Suzhou) Co., Ltd. 59 No.59, Chang Sheng Road, Sheng Pu, APPROVAL SHEET CUSTOMER ituner CUSTOMER P/N DESCRIPTION EDAC MODEL 12V/6.6A SERIES NO. (E17) EA10953A DATE 2010-06-22 REVISION 0 APPROVED DESIGN PREPARE RoHS CONCLUSION APPROVED CONDITON CUSTOMER S APP

More information

SILENT POWER RELAY. FTR-H3 Series. 1 POLE - 78A/120A Inrush Current Type FTR-K1 SERIES FEATURES

SILENT POWER RELAY. FTR-H3 Series. 1 POLE - 78A/120A Inrush Current Type FTR-K1 SERIES FEATURES FTR-K1 SERIES SILENT POWER RELAY 1 POLE - 78A/120A Inrush Current Type FTR-H3 Series FEATURES Pin compatible with widely used VS and FTR-H1 series power relays Silent relay with patented unique U-shape

More information

Optocoupler, Phototransistor Output, with Base Connection, 300 V BV CEO

Optocoupler, Phototransistor Output, with Base Connection, 300 V BV CEO SFH64 Optocoupler, Phototransistor Output, with Base Connection, 3 V BV CEO i1794-3 DESCRIPTION The SFH64 is an optocoupler with very high BV CER, a minimum of 3 V. It is intended for telecommunications

More information

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2... Magnetic and Hydraulic-Magnetic Circuit Breaker 840-G2... Description Single, two and three pole magnetic circuit breakers with trip-free mechanism and push/pull on/off manual actuation. A choice of fast

More information

1 POLE 5 A (CADMIUM FREE CONTACTS TYPE) NY SERIES

1 POLE 5 A (CADMIUM FREE CONTACTS TYPE) NY SERIES POWER RELAY 1 POLE 5 A (CADMIUM FREE CONTACTS TYPE) NY SERIES RoHS compliant FEATURES Ultra slim type with 5 mm thickness Good for high density mounting Low power consumption and high sensitivity Nominal

More information

Thermistor motor protection

Thermistor motor protection Thermistor motor protection CM-E Range Thermistor motor protection Thermistor motor protection relays Benefits and advantages Selection table Operating principle and fields of application for thermistor

More information

Safety automation solutions

Safety automation solutions Operating principle, characteristics Preventa safety s types XPS AV,, For and switch monitoring Operating principle Safety s XPS AV, and are used for monitoring circuits conforming to standards EN/ISO

More information

1 POLE - 16A / Inrush 120A relay. (a) Relay type FTR-K1 : FTR-K1 Series (b) Contact configuration A : 1 form A C : 1 form C

1 POLE - 16A / Inrush 120A relay. (a) Relay type FTR-K1 : FTR-K1 Series (b) Contact configuration A : 1 form A C : 1 form C FTR-K1 SERIES POWER RELAY 1 POLE - 16A / Inrush 120A relay FTR-K1-KS Series FEATURES 1 pole 16A, 1 form A or 1 form C Peak inrush current 120A / TV-8 Coil power 400mW High insulation in small package (between

More information

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592. * see variants. Applications.

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592. * see variants. Applications. Safety Technique SAFEMASTER Emergency Stop Module BG 5924, IP 5924 Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592 BG 5924 IP 5924 Product Description

More information

1 POLE - 8A Medium Load Control

1 POLE - 8A Medium Load Control POWER RELAY 1 POLE - 8A Medium Load Control JS Series FEATURES UL class B (130 C) coil wire insulation 1 form A (SPST-NO) or 1 form C (SPDT) contact Low profile and space saving - Height: 12.5 mm - Mounting

More information

1 POLE - 5A SLIM POWER RELAY

1 POLE - 5A SLIM POWER RELAY POWER RELAY POLE - A SLIM POWER RELAY FTR-MY Series RoHS compliant FEATURES Width mm, height mm,(% smaller than NY series) area mm, super slim, low power, compact and light weight.gr. Nominal power: mw

More information

Safety technique. Emergency stop module BO 5988 safemaster

Safety technique. Emergency stop module BO 5988 safemaster Safety technique Emergency stop module BO 5988 safemaster 0221562 Function diagram Pushbutton on Mains or emergencystop () K1 According to EC Directive for machines 98/37/EG According to IEC/E 60204-1

More information

Custom Products. Magnetic Components. Vishay Dale. www.vishay.com

Custom Products. Magnetic Components. Vishay Dale. www.vishay.com Magnetic Components SWITCH MODE MAGNETICS AIR CORE INDUCTORS INDUCTIVE PRODUCTS CUSTOM DESIGN AND PRODUCTION has extensive facilities for custom design and production of custom magnetics. Design applications

More information

Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated. Ordering information

Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated. Ordering information Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated Ordering information Connection technique Description Description Rated operational current Screw terminals 3 pole AC

More information

Installation Contactors. Technical Catalogue. Type ESB. abb. ABB STOTZ-KONTAKT GmbH 1 2CDC 103002 C0201

Installation Contactors. Technical Catalogue. Type ESB. abb. ABB STOTZ-KONTAKT GmbH 1 2CDC 103002 C0201 Technical Catalogue Installation Contactors Type ESB abb ABB STOTZ-KONTAKT GmbH 1 CDC 10300 C001 ABB STOTZ-KONTAKT GmbH CDC 10300 C001 Low Voltage Products and Systems We ensure safety and comfort for

More information

Preset Counter signo 721

Preset Counter signo 721 Most simple handling Impressive, clearly readable display in 48x48 mm Input frequency up to 60 khz Easy installation due to pluggable terminals TECHNICAL DATA GENERAL Display Height of digits Supply voltage

More information

Catalog. Modular DIN rail components Installation contactors

Catalog. Modular DIN rail components Installation contactors Catalog Modular DIN rail components Installation contactors 0 CDC00C00 Installation contactors Benefits and features Overview Ordering details ESB installation contactors ESB0 ESB ESB0 ESB 7 EN installation

More information

KSC Series Sealed Tact Switch for SMT

KSC Series Sealed Tact Switch for SMT KSC Series Features/enefits Positive tactile feeling J or G terminations Various heights IP67 Typical Applications Automotive Cellular phones Industrial electronics Network infrastructure and IT Elevator

More information

7000 Series Buccaneer

7000 Series Buccaneer The all plastic and metal construction of the - circular that combine the ease of use of a quick coupling mechanism with proven environmental sealing for signal and mains power. Designed and independently

More information

5SV Residual Current Protective Devices

5SV Residual Current Protective Devices s Siemens AG 2013 SENTRON 5SV Residual Current Protective Devices New portfolio for reliable personnel, material and fire protection Safe protection against residual currents Residual current protective

More information

SPST-NO SPDT DPST-NO DPDT

SPST-NO SPDT DPST-NO DPDT PCB Relay Next-generation PCB Relay Available in 2 Models Low profile:. mm max. in height Contains no lead inside and features cadmium-free contacts ensuring environment-friendly use. Conforms to VDE0

More information

Optocoupler, Phototransistor Output, with Base Connection

Optocoupler, Phototransistor Output, with Base Connection HA/HA2/HA3/HA4/HA5 FEATURES Interfaces with common logic families Input-output coupling capacitance < pf Industry standard dual-in line 6-pin package A C NC 2 3 6 5 4 B C E Isolation test voltage: 5300

More information

BETA Protecting SITOR Semiconductor Fuses

BETA Protecting SITOR Semiconductor Fuses BETA Protecting SITOR Semiconductor Fuses /2 Product overview /3 /17 SITOR, cylindrical fuse design /22 SILIZED, NEOZED and DIAZED design Siemens ET B1 /2008 Product overview Overview Devices Page Field

More information

LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A - 220 V AC coil

LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A - 220 V AC coil Product data sheet Characteristics LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 -

More information

SVR 12/24V and SVR Akku 12V Installation instructions

SVR 12/24V and SVR Akku 12V Installation instructions U aus Akku Na 12/24V SVR 12V/24V 700 800 500 SVR Akku 12V 700 800 550 230V~ L1 N SVR 12/24V and SVR Akku 12V Installation instructions Table of Contents General.... 3 Installation Putting into Operation...

More information

Optocoupler, Phototransistor Output, with Base Connection

Optocoupler, Phototransistor Output, with Base Connection Optocoupler, Phototransistor Output, with Base Connection FEATURES i794-4 DESCRIPTION This datasheet presents five families of Vishay industry standard single channel phototransistor couplers. These families

More information

Product Catalogue. Relays with forcibly guided contacts

Product Catalogue. Relays with forcibly guided contacts Product Catalogue Relays with forcibly guided contacts Product Catalogue - Relays with forcibly guided contacts Edition / Publisher: ELESTA relays GmbH, Bad Ragaz, Switzerland All rights reserved. This

More information

1 POLE - 16A 80A Inrush type. (a) Relay type FTR-K1 : FTR-K1-Series

1 POLE - 16A 80A Inrush type. (a) Relay type FTR-K1 : FTR-K1-Series FTR-K1 SERIES POWER RELAY 1 POLE - 16A 80A Inrush type FTR-K1 Series FEATURES Peak 80A inrush current (1 form A type) Low profile (height: 15.7mm) High insulation Insulation distance (between coil and

More information

POWER RELAY. JV Series. 1 POLE - 5A/10A Medium Load Control FTR-K1 SERIES FEATURES

POWER RELAY. JV Series. 1 POLE - 5A/10A Medium Load Control FTR-K1 SERIES FEATURES FTR-K1 SERIES POWER RELAY 1 POLE - 5A/10A Medium Load Control JV Series FEATURES UL, CSA, VDE, SEMKO, CQC recognized UL class B (130 C) wire class Low profile and space saving - Height: 12.5 mm - Mounting

More information

BRÖCKSKES D-VIERSEN PV1-F 4,0 mm BRÖCKSKES D-VIERSEN PV1-F 4,0 mm d d 2 2 C VDE-REG.-Nr. 8292 10/2009

BRÖCKSKES D-VIERSEN PV1-F 4,0 mm BRÖCKSKES D-VIERSEN PV1-F 4,0 mm d d 2 2 C VDE-REG.-Nr. 8292 10/2009 d BRÖCKSKES BRÖCKSKES D-VIERSEN D-VIERSEN PV1-F PV1-F 4,0 mm 4,0 2 mm VDE-REG.-Nr. 2 C 8292 10/2009 s - THE COMPANY DIN EN ISO 9001 More than 60 years of experience in temperature measurement and control

More information

LOGO!Power. Power supply. LOGO!Power. Overview. Safety instructions. Description, device design, dimension drawing. Mounting/disassembly

LOGO!Power. Power supply. LOGO!Power. Overview. Safety instructions. Description, device design, dimension drawing. Mounting/disassembly Overview Safety instructions 1 Power supply Operating Instructions Description, device design, dimension drawing 2 Mounting/disassembly 3 Mounting position, mounting clearances 4 Installation 5 Technical

More information

40.3. Control Relays and Timers

40.3. Control Relays and Timers .3 Contents EASY500/700/800 Intelligent Relays........ EASY/MFD Expansion Modules............ MFD Intelligent Relays................... EASY/MFD Communication Modules....... EASY/MFD Power Supplies, Accessories

More information

Type: EASY719 DC RC Article No.: 274119. Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

Type: EASY719 DC RC Article No.: 274119. Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description Type: EASY719 DC RC Article.: 274119 Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC Description 12 digital inputs (4 inputs available as analog inputs) 6 relay outputs LCD display

More information

Optocoupler, Phototransistor Output, with Base Connection

Optocoupler, Phototransistor Output, with Base Connection 4N25, 4N26, 4N27, 4N28 Optocoupler, Phototransistor Output, FEATURES A 6 B Isolation test voltage 5000 V RMS Interfaces with common logic families C 2 5 C Input-output coupling capacitance < pf NC 3 4

More information

How To Protect A Motor From Overcurrent

How To Protect A Motor From Overcurrent Phase ailure elays Type PS and PD Class 8430 Catalog 04 CONTENTS Description.....................................................Page Product Description and Definitions......................................

More information

Thyristor-controlled power supplies and battery chargers

Thyristor-controlled power supplies and battery chargers Thyristor-controlled power supplies and battery chargers Input voltage: 115 / 230 VAC, single phase, 50 / 60 Hz or 208 / 400 / 480 VAC, three phases, 50 / 60 Hz Output voltage: 12 / 24 / 48 / 60 / 72 /

More information

2.12. page 223 2.12. Products for Explosion hazardous Environment

2.12. page 223 2.12. Products for Explosion hazardous Environment 2.12 page 223 2.12 Products for Explosion hazardous Environment Non-electric valves for explosion 2.12.1 page 224 hazardous environment The following manually and mechanically actuated valves are available

More information

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1 Power Supply Unit, Primary Switched, Narrow Design MINI POWER provides: Extra narrow design with widths of 22.5 mm, 45 mm, and 67.5 mm (0.886, 1.772, and 2.657 in.) Global use due to a wide-range input

More information

Power Supplies 3. SDN-P DIN Rail Series

Power Supplies 3. SDN-P DIN Rail Series SDN-P DIN Rail Series The SDN DIN Rail power supplies provide industry leading performance. Sag Immunity, transient suppression and noise tolerant, the SDN series ensures compatibility in demanding applications.

More information

Optocoupler, Photodarlington Output, Dual Channel, SOIC-8 Package

Optocoupler, Photodarlington Output, Dual Channel, SOIC-8 Package Optocoupler, Photodarlington Output, i179042 DESCRIPTION A1 C 2 A3 C4 8 C 7E 6C 5E The ILD233T is a high current transfer ratio (CTR) optocoupler. It has a gallium arsenide infrared LED emitter and silicon

More information

1a/1c 5A/10A small power relays

1a/1c 5A/10A small power relays VDE a/c A/A small power relays RELAYS RoHS compliant FEATURES High electrical noise immunity High switching capacity in a compact package High sensitivity: mw (a), mw (c) High surge voltage:, V between

More information

Top Microsystems Proprietary Specification P/N: W090015HK-XP 022410RB-082709V.A0 SPECIFICATION

Top Microsystems Proprietary Specification P/N: W090015HK-XP 022410RB-082709V.A0 SPECIFICATION SPECIFICATION High Quality Switching Wallmount Adapter Interchangeable AC Plugs 90-264VAC Input 13.5W 9VDC 1.5A Output P/N: W090015HK-XP ** Specification Approval** This specification (total 11 pages including

More information

Feed-through terminals

Feed-through terminals s Screw connection system RKB 4 BKA 2,5 BKA 4 BKA 0 Rail mount on TS 5 / TS 32 / TS 35 / Direct mounting Connection diagram M 3 M 2,5 M 3 M 4 Connection type Dimension (L x W x H) with TS 5 mm with TS

More information

Cable Plug acc. to DIN EN 175301-803, Form A

Cable Plug acc. to DIN EN 175301-803, Form A Cable Plug acc. to DIN EN 175301-803, Form A Complete program Contact form 18 mm Also available with LED indicator Optional 4-pin version for pressure switch or impulse valves respectively Versions with

More information

SOLAR MICRO INVERTER 260 COMMUNICATION GATEWAY. Apparent Power Control (APC) unique micro inverter with

SOLAR MICRO INVERTER 260 COMMUNICATION GATEWAY. Apparent Power Control (APC) unique micro inverter with SOLAR MICRO INVERTER 260 COMMUNICATI GATEWAY Apparent Power Control (APC) P Q unique micro inverter with REAL & REACTIVE POWER CTROL 2 Micro Inverters unique micro inverter with real & reactive power control

More information

HSP GmbH Zum Handwerkerhof 2 90530 Wendelstein Tel. 09129 / 2852-0 Fax: 09129 / 2852-11 Web: www.hsshsp.de EMAIL: HSP@hsshsp.de NTG-3000.

HSP GmbH Zum Handwerkerhof 2 90530 Wendelstein Tel. 09129 / 2852-0 Fax: 09129 / 2852-11 Web: www.hsshsp.de EMAIL: HSP@hsshsp.de NTG-3000. NTG-3000 Transducer Data Sheet Document Version 2.8 Page 1 of 10 Versions / Revisions: Document Creation Author Description version date 2.0 2012-07-25 P. Compensis First official version 2.1 2012-08-24

More information

Technical catalogue. Modular DIN rail components Installation contactors

Technical catalogue. Modular DIN rail components Installation contactors Technical catalogue Modular DIN rail components Installation contactors Installation Contactors Overview... ESB Installation Contactors 0 A / AC-/AC-7a ESB0...4 4 A / AC-/AC-7a ESB4...5 40 A / AC-/AC-7a

More information

Fuses for Semiconductor Protection - Cylindrical Fuses. Class: Voltage ratings: Current ratings: Standards: Approvals: Features and Benefits

Fuses for Semiconductor Protection - Cylindrical Fuses. Class: Voltage ratings: Current ratings: Standards: Approvals: Features and Benefits Fuses for Semiconductor Protection - Cylindrical Fuses SIBA cylindrical Ultra-Rapid fuses are available in six different sizes They can be ordered with an integral striker for blown fuse indication or

More information

VEO. V4PF480Y/277VSYTK02 Art.Nr.: 2104200. V4PF480Y/277VSYTK02P Art.Nr.: 2104210 TECHNICAL DATA

VEO. V4PF480Y/277VSYTK02 Art.Nr.: 2104200. V4PF480Y/277VSYTK02P Art.Nr.: 2104210 TECHNICAL DATA Monitoring of phase sequence and phase loss Monitoring of asymmetry Temperature monitoring (PTC) Supply voltage 208-480 V AC Supply circuit = measuring circuit 2 change-over contacts Width 45 mm Control

More information

Goodsky Technical Data. Contact Details

Goodsky Technical Data. Contact Details Goodsky Technical Data The following page(s) are extracted from multi-page Goodsky product catalogues or CDROMs and any page number shown is relevant to the original document. The PDF sheets here may have

More information

ADM1TE 5/30A DIN rail single phase two wire energy meter

ADM1TE 5/30A DIN rail single phase two wire energy meter ADMTE 5/30A DIN rail single phase two wire energy meter. Safety instruction.2 Foreword.3 Performance criteria.4 Specifications.5 Basic errors.6 Description.7 Dimensions.8 Installation.9 Operating.0 Troubleshooting.

More information

General Purpose Relays Types K, R, N, and C

General Purpose Relays Types K, R, N, and C General Purpose Relays s K, R, N, and C Catalog 0CT00R/0 00 Class 0 CONTENTS Description............................................. Page R Miniature Plug-in Relays.............................. K Plug-in

More information

L-LAS-TB-CL serie. laser light curtains for inline measuring tasks

L-LAS-TB-CL serie. laser light curtains for inline measuring tasks L-LAS-TB-CL serie laser light curtains for inline measuring tasks Maximum distance 2.000 mm Measurement range 6 up to 98 mm Resolution up to 4 µm up to 1,5 khz scan rate 0-10 V or 4-20 ma analogue output

More information

3753 en - 04.2004/b VE/B - VE/RG Va V riable speed drives

3753 en - 04.2004/b VE/B - VE/RG Va V riable speed drives 3753 en 04.2004/b Variable speed drives LEROYSOMER's drives provide SPEED VARIATION for a DC motor, SIMPLY and ECONOMICALLY from a singlephase power supply. CMStype technology is used. These products conform

More information

keep your measure under control

keep your measure under control INSTRUMENTACIÓN INDUSTRIAL ZURC, S.A. keep your measure under control CURRENT For measuring instruments. Mounted in selfexinguishing, plastic, strengthened cases. Isolation voltage V Made as per UNEEN

More information

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version) TECHNICAL DATASHEET #TD1102AX CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version) Part Number: Connector Amplifier CAPV-H-4-20MA-x complete with cable CAPV-4C-yM Where: x = current output

More information

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector Product datasheet Characteristics TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector Main Range of product Product or component type Range compatibility Enclosure material Bus

More information

Control- and feedback head for integrated mounting on Robolux valves Type 2036

Control- and feedback head for integrated mounting on Robolux valves Type 2036 Control- and feedback head for integrated mounting on Robolux valves Type 203 Type 885 Type 88 can be combined with Compact stainless steel design Contactless valve position registration Coloured illuminated

More information

Preventa Machine Safety Products

Preventa Machine Safety Products Preventa Machine Safety Products Catalog 2009 200 Supplement Safety Relay Modules 2 Contents Preventa safety relay modules Selection guide 2 Electrical Ratings 6 Types XPSAC and XPSAXE For Emergency stop

More information

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points Features SELV Compliant No Detection Passive Injector Gigabit Compatible Full Protection

More information

Safety Relays ESM/ESM-F

Safety Relays ESM/ESM-F Safety Relays ESM/ESM-F More than safety. Safety More than safety. Emil Euchner, the company s founder and inventor of the multiple limit switch, circa 1928. Around the world the Swabian specialists in

More information

DISCONTINUED (2012) VB SERIES 2 POLE 5 A (MEDIUM LOAD CONTROL) POWER RELAY. RoHS compliant

DISCONTINUED (2012) VB SERIES 2 POLE 5 A (MEDIUM LOAD CONTROL) POWER RELAY. RoHS compliant POWER RELAY 2 POLE 5 A (MEDIUM LOAD CONTROL) VB SERIES RoHS compliant FEATURES UL, CSA, VDE, SEV, SEMKO, CQC recognized TV-3 rated Working class: C UL class B (130 C) insulation Type of service: continuous

More information

(e) Enclosure B : Flux proof type, RTII C : Plastic sealed type (with tape), RTIII K : Plastic sealed type, RTIII

(e) Enclosure B : Flux proof type, RTII C : Plastic sealed type (with tape), RTIII K : Plastic sealed type, RTIII Non-promotional not for new designs FTR-K1 SERIES POWER RELAY 1 POLE - 10A VS Series FEATURES UL, CSA, VDE, SEV, SEMKO, CQC recognized TV-5 is available Working class: C UL class B (130 C) coil wire insulation

More information

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application 33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application Features Compliant with the IEEE802.3at Standard -40 to +60 C Temperature Range Diagnostic LEDs Full Protection

More information

ABB i-bus KNX Switch Actuator, x-fold, 16 A, MDRC SA/S x.16.2.1, 2CDG1101xxR0011

ABB i-bus KNX Switch Actuator, x-fold, 16 A, MDRC SA/S x.16.2.1, 2CDG1101xxR0011 Technical Data 2CDC505051D0205 ABB i-bus KNX Product description Switch Actuators SA/S x.16.2.1, 16 A are modular installation devices in ProM design for installation in the distribution board. They are

More information

Throughbeam photoelectric sensors. Dimensioned drawing. Electrical connection

Throughbeam photoelectric sensors. Dimensioned drawing. Electrical connection Specifications and description Leuze electronic LS 78 Throughbeam photoelectric sensors Dimensioned drawing 180m 10-30 V DC! Voltage range from 12 30VDC with NPN, PNP and/or relay outputs! Light/dark switching!

More information

Operating Manual UWAPS-TINY Series

Operating Manual UWAPS-TINY Series Operating Manual UWAPS-TINY Series Powecon Oy WWW.POWECON.FI 1/9 Table of content 1 Warranty...3 2 Safety information...3 3 Abbreviations and terminology...3 4 List of appendices...4 5 Introduction...4

More information

NA Series. 2 POLES - 1 to 2 A (For Signal Switching) MINIATURE RELAY FTR-K1 SERIES

NA Series. 2 POLES - 1 to 2 A (For Signal Switching) MINIATURE RELAY FTR-K1 SERIES FTR-K1 SERIES MINIATURE RELAY 2 POLES - 1 to 2 A (For Signal Switching) NA Series FEATURES Slim type relay for high density mounting Conforms to Telcordia specification and FCC Part 68 - Dielectric strength

More information

ISIO 200. Binary Input/Output (I/O) Terminal with IEC 61850 Interface

ISIO 200. Binary Input/Output (I/O) Terminal with IEC 61850 Interface ISIO 200 Binary Input/Output (I/O) Terminal with IEC 61850 Interface Compact and Easy ISIO 200 Put your Binary I/Os where you need them ISIO 200 is a simple and versatile binary I/O terminal with IEC 61850

More information

DS 600. A contact free flux gate based current measurement sensor 600A rms

DS 600. A contact free flux gate based current measurement sensor 600A rms DS 600 A contact free flux gate based current measurement sensor 600A rms DS 600 is member of the small housing sensor family. The family includes a 200A and a 600A version. 600A rms - 900A peak Maximum

More information

Thermal-Magnetic Circuit Breaker 3120-...-M1-..

Thermal-Magnetic Circuit Breaker 3120-...-M1-.. Thermal-Magnetic Circuit Breaker -...-M-.. Description Single or two pole rocker switch/thermal-magnetic circuit breaker with trip-free mechanism (S-type TM CBE to EN 34). The addition of a magnetic tripping

More information

30-120 3 Phase Modular Finally the benefits of Modular ups are for all

30-120 3 Phase Modular Finally the benefits of Modular ups are for all MUST 30-120 3 Phase Modular UPS Finally the benefits of Modular ups are for all MUST 30-120 MUST means Modular UPS System Three-phase MUST 30-120 is an uninterruptible power supply with double conversion

More information

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv) Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv) Order code Series and function 1) Plug socket see page 5.042. MN-06-310-HN-442 Standard coil 1) 441 = 12 V DC, 4.2 W 442 = 24 V DC,

More information

IntesisBox KNX LG Air Conditioning

IntesisBox KNX LG Air Conditioning IntesisBox KNX LG Air Conditioning Gateway for integration of LG Air Conditioners with KNX control systems. 1. Main Features Direct connection to KNX TP-1 (EIB) bus. Direct connection to LG outdoor unit

More information

3/2- and 2/2-way cartridge valve type BVE

3/2- and 2/2-way cartridge valve type BVE 3/2- and 2/2-way cartridge valve type BVE for any flow direction, zero leakage, all ports pressure resistant Flow Q max = 70 lpm Perm. pressure p max = 400 bar Additional valves with same function: ' Type

More information

TLK 48 MICROPROCESSOR-BASED DIGITAL ELECTRONIC REGULATOR

TLK 48 MICROPROCESSOR-BASED DIGITAL ELECTRONIC REGULATOR TLK 48 MICROPROCESSOR-BASED DIGITAL ELECTRONIC REGULATOR TECHNICAL DATA CARATTERISTICHE MECCANICHE Housing Self-extinguishing plastic, UL 94 V0 Dimensions 48x48 mm DIN depth 98 mm Weight 225 g approx.

More information

1 Form A Solid State Relay

1 Form A Solid State Relay 1 Form A Solid State Relay Vishay Semiconductors DIP i1791- SMD DESCRIPTION Vishay solid state relays (SSRs) are miniature, optically coupled relays with high-voltage MOSFET outputs. The LH1518 relays

More information

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw 4 937 DESIO Current valve for AC 24 V pulse/pause control of electrical loads up to 30 kw SEA45.1 Use The current valve is used for the control of electric heating elements in heating, ventilation and

More information

NEC Class 2 Power Circuits and Power Supplies

NEC Class 2 Power Circuits and Power Supplies NEC Class 2 Power Circuits and Power Supplies Abstract: The NEC (National Electrical Code) is a North American standard, which can be regarded as a law in most of the North American states. Among others,

More information

Chrome DIN Rail Power Supply 24V 30W 1 Phase (Class II & NEC Class 2) / DRC-24V30W1AZ

Chrome DIN Rail Power Supply 24V 30W 1 Phase (Class II & NEC Class 2) / DRC-24V30W1AZ Highlights & Features Protection Class II, Double Isolation (No Earth connection is required) Universal AC input voltage without power de-rating Efficiency > 87.0% @ 115Vac & 230Vac NEC Class 2 / Limited

More information

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features Central 48 V DC Power Supplies for PoE-Components MICROSENS Description Active network equipment which is supporting the Power-over-Ethernet functions, typically requires a powerful 48 V DC power supply.

More information