Product Catalogue. Relays with forcibly guided contacts
|
|
- Marian Malone
- 8 years ago
- Views:
Transcription
1 Product Catalogue Relays with forcibly guided contacts
2 Product Catalogue - Relays with forcibly guided contacts Edition / Publisher: ELESTA relays GmbH, Bad Ragaz, Switzerland All rights reserved. This work and its parts are protected by copyright. Any use in other than legally authorized cases requires the prior written consent of the publisher.
3 The comp ELESTA relays GmbH was founded in 997 as a producer of relays with forcibly guided contacts, but our roots date back to the middle of the last century. Since then, relays have been designed and manufactured in Bad Ragaz in the Swiss canton of St. Gallen. The distinctive feature of these electromechanic relays is the special contact set compliant with EN 55. All contacts are interlinked in such a way that NC contact and NO contact must never be closed simultaneously, even in case of a fault. Relays with forcibly guided contacts are primarily used in control units for functional safety applications, and therefore wherever life and health of people need to be protected. Through the use of relays with forcibly guided contacts load and monitoring circuits can easily be linked together in safety controls. High diagnostic coverage and reliability are characteristics that predestine these relays for use in machine and plant construction as well as in process technology, medical equipment, elevator controls or railway technology, to name just a few applications. 7 relay series with to contacts form the basis for a large number of variants, covering switching currents from ma to A as well as excitation voltages of up to. Owing to the use of advanced materials and newly developed contact systems our relays guarantee superior system vers and carefully selected materials support the eco-friendly control design. are tailored to the requirements of our customers. The possibilities range from simple coil adjustments to encoded sets of contacts with special relay drivers. This includes variants that are geared towards compliance with certain stan- (railway applications). These individual solutions are developed in close dialogue with the customer. In doing so, customers can, of course, depend on Innovation is our impetus. A wealth of experience and continuous training, close cooperation with research institutions and suppliers, as well as active participation in technical and standardization bodies enables us to implement new technologies and market requirements in forward-looking products early on. The entire comp of Elesta relays GmbH follows the LEAN principle. Clear structures are evident not only in our Green Factory (which does not require fossil fuels) but also in our operations (for which we often set higher standards than is required by EN ISO 9:). High product quality, supply readiness and service quality are the three pillars on which the comp rests. At the same time they are the guiding principles our employees identify with. The deployment of relays with forcibly guided contacts requires trust; a responsibility that we readily accept. Harald Förster Geschäftsführer / CEO ELESTA relays GmbH ELESTA relays GmbH, Heuteilstrasse, CH - 7 Bad Ragaz, Switzerland Fon: + () 5 Fax: + () 5 Copyright /
4 Product Overview Relays with forcibly guided contacts Relays SIS SIS SIS sen SIS SIS SIF SIF SIF SIR SIR sen Features Number of Contacts Contact Material Type of Contact Coil Voltage Small dimensions High shock resistance Large excitation voltage Low coil power loss High switching reliability Very small dimensions High shock resistance Large excitation voltage Very high switching reliability Very small dimensions High shock resistance Large excitation voltage Low coil power loss High switching reliability High shock resistance Large excitation voltage Low coil power loss Very high switching reliability Very small dimensions High shock resistance Large excitation voltage Very high switching reliability Available by end of design Large switching current range Possible component installation under the relay design Large switching current range Possible component installation under the relay Classic CO relay Extrusioncoated coil design suitable for use in ATEX areas Classic CO relay Low coil power loss Extrusioncoated coil design suitable for use in ATEX areas SGR Z Classic CO relay Extrusioncoated coil design suitable for use in ATEX areas CO CO CO CO SGR Z sen Classic CO relay Low coil power loss Extrusioncoated coil design suitable for use in ATEX areas AgCuNi AgCuNi AgCuNi AgCuNi AgCuNi AgCuNi AgCuNi AgCuNi AgSnO AgSnO AgCuNi AgCuNi Notched crown Notched crown Notched crown Notched crown Notched crown Notched crown Notched crown Notched crown Single contact Single contact 5 - Single contact Single contact Coil 7mW mw mw 5mW mw mw 7mW mw mw 7mW mw 7mW Capacity Switching Current Range Test Voltage Open Contact Test Voltage between Contacts Test Voltage Coil/ Contact ma - A ma - A ma - A ma - A ma - A ma - A ma - A ma - A ma - A ma - A ma - A ma - A 5Veff 5Veff 5Veff 5Veff 5Veff 5Veff 5Veff 5Veff 5Veff 5Veff 5Veff 5Veff 5 Veff Veff Veff Veff Veff Veff Veff Veff Veff Veff Veff Veff 5Veff 5Veff 5Veff Veff (SIS) 5Veff (SIS) Not for new new wd designs will bee replaced placed ed by y SGR R ZK 5Veff Veff Veff Veff 5 Veff 5 Veff 5 Veff 5 Veff Protection RT RT RT RT RT (external) in mm L 9. W. H.5 L 9. W. H.5 L 9. W. H.5 L W. H.5 L W. H.5 L.7 W 9. H.9 L W 9. H.9 L 5. W.5 H.9 L. W.7 H 5. L. W.7 H 5. L. W.7 H 5. L. W.7 H 5. Options (see catalogue) UL, cul, TÜV page page page page page page 5 page page 7 page available late page 9 page page page page page Reference temperature C Between left and right contact side 5 Between control and output contacts Between control contacts Between output contacts Copyright / ELESTA relays GmbH, Heuteilstrasse, CH - 7 Bad Ragaz, Switzerland Fon: + () 5 Fax: + () 5
5 Product Overview Relays with forcibly guided contacts SGR ZK SIM SIM SIM SLR SIR SIR sen SIR P SIR SIR sen SIR SIR SIP Extrusioncoated coil design suitable for use in ATEX areas Very high switching reliability Extrusioncoated coil design suitable for use in ATEX areas High switching reliability Extremely high leakage and creepage distances Extrusioncoated coil design suitable for use in ATEX areas High switching reliability Extremely high leakage and creepage distances Extrusioncoated coil design suitable for use in ATEX areas High switching reliability Extremely high leakage and creepage distances Powerful Small, horizontal design Large switching current range High switching reliability Powerful Small design High switching reliability Powerful Small design High switching reliability Low coil power loss Wide coil working range Extremely powerful Small design For loads with a high surge current High switching reliability Powerful Small design High switching reliability Contact assignment Powerful Small design High switching reliability Low coil power loss Wide coil working range Contact assignment Powerful High switching reliability Wide coil working range Contact assignment Powerful High switching reliability Wide coil working range Contact assignment Extremely powerful High switching reliability For the highest loads during -phase applications and DC loads CO AgCuNi AgSnO AgSnO AgSnO AgSnO AgSnO AgSnO AgSnO AgSnO AgSnO AgSnO AgSnO AgSnO Notched crown Crest contact Crest contact Crest contact Crest contact Crest contact Crest contact Single contact Crest contact Crest contact Crest contact Crest contact Single contact 7mW 5mW 75mW mw mw mw mw 75mW 75mW 5mW mw mw mw ma - A ma - A ma - A ma - A ma - A ma - A ma - A 5mA - A ma - A ma - A ma - A ma - A 5mA - A 5Veff 5Veff 5Veff 5Veff 5Veff 5Veff 5Veff 5Veff 5Veff 5Veff 5Veff 5Veff 5Veff Veff Veff 5Veff Veff 5Veff Veff Veff Veff 5 5 Veff 5Veff 5 Veff 5 Veff 5Veff 5 Veff 5 Veff 5Veff 5 Veff 5 Veff 5Veff 5 Veff 5 Veff 5Veff 5 Veff 5 Veff Veff Veff 5Veff 5 Veff 5 Veff 5 Veff 5 Veff 5 Veff 5 Veff 5Veff 5Veff 5Veff 5Veff 5Veff 5Veff 5 Veff 5Veff 5Veff L. W.7 H 5. L 7. W.5 H. L. W.5 H. L. W.5 H. L 5. W. H.5 L. W H.7 L. W H.7 L. W H.7 L 5.9 W H.7 L 5.9 W H.7 L 5.5 W H L 5.5 W H L. W H UL, cul, TÜV page - page 9 page 9 - page page page page page page 5 page page 7 page page 9 page page page page page page 5 page page 7 ELESTA relays GmbH, Heuteilstrasse, CH - 7 Bad Ragaz, Switzerland Fon: + () 5 Fax: + () 5 Copyright /
6 SIS Series - Protective separation between control and load curcuit (leakage and creepage distances >mm) - EN55 type A - Double and reinforced insulation between the contacts - Contact mounting: SIS NO / NC - Small external dimensions - Mean coil power.7 W - Holding coil power. W - For railway application (EN555) on request.5 ± Ø Contact Data AgCuNi+.-.μm Au Type of contact Single contact with notched crown Rated switching capacity 5VAC A AC 5VA Electr. life AC ( cycles/h) >9 A for ms 5 to 5 /VAC ma to A Switching capacity range* mw to 5W(VA) Min. pick-up voltage at C Drop-out voltage at C Resistance in Ohm at C ± %. ± % ± %. 5 ± % 5. ± %. ± % ± %.5 ± 5% A SIS A - Basic insulation at 5VAC - Air and creepage distance >mm - Test voltage 5V/5Hz/min - Double or reinforced insulation at 5VAC - Air and creepage distance >mm - Test voltage 5 V/5Hz/min Test voltage contact open 5V/5Hz/min Creepage resistance CTI 75 Pollution degree >x operations 5Hz typically ms typically ms typically ms typically 5ms Shock resistance ms NO > 7g NC > 7g NO > 7g (-Hz) NC > g A SCPD A gg/gl (pre-fuse) - C to +7 C Thermal Resistance 55K/W Temperature limit for coil C ca. g RT 7 C/5s UL File E95 Sec. 5 Insulation class IEC - 5VAC Protection class II VDE UL 9 / V none available SIS Contact Lifetime for NO Contacts Operations x DC : V AC :V AC 5: V DC : V Maximal switching characteristics(en97-5-) AC : 5V / A AC 5: V / A DC : V / A DC : V / 5A /.Hz UL 5: B / R Operations x ) Inductive load L/R ms ) Resistive load ) ) Min. excitation voltage (guaranteed values) without No heat accumulation due to intrinsic heating of other components. Continuous duty %. Copyright / ELESTA relays GmbH, Heuteilstrasse, CH - 7 Bad Ragaz, Switzerland Fon: + () 5 Fax: + () 5
7 SIS Series - Protective separation between control and load curcuit (leakage and creepage distances >mm) - EN55 type A - Double and reinforced insulation between the contacts - Contact mounting: SIS NO / NC - Small external dimensions - Mean coil power. W - Holding coil power. W - For railway application (EN555) on request.5 ± Ø Contact Data AgCuNi+.-.μm Au Type of contact Single contact with notched crown Rated switching capacity 5VAC A AC 5VA Electr. life AC ( cycles/h) >9 A for ms 5 to 5 /VAC ma to A Switching capacity range* mw to 5W(VA) at C C at C 5..5 ± % 9. 5 ± % 5. ± %. 5 ± % 5. 9 ± %.5 ± %. ± % 5. 5 ± 5% A SIS A - Basic insulation at 5VAC - Air and creepage distance >mm - Test voltage 5V/5Hz/min - Double or reinforced insulation at 5VAC - Air and creepage distance >5.5mm - Test voltage V/5Hz/min - Double or reinforced insulation at 5VAC - Air and creepage distance >mm - Test voltage V/5Hz/min Test voltage contact open 5V/5Hz/min Creepage resistance CTI 75 Pollution degree >x operations 5Hz typically ms typically ms typically ms typically 5ms Shock resistance ms NO > 7g NC > g NO > 7g (-Hz) NC > g A SCPD A gg/gl (pre-fuse) - C to +7 C Thermal Resistance 55K/W Temperature limit for coil C ca. g RT 7 C/5s UL File E95 Sec. 5 Insulation class IEC - 5VAC Protection class II VDE UL 9 / V none available SIS Contact Lifetime for NO contacts Operations x DC : V AC :V AC 5: V DC : V Maximal switching characteristics (DIN EN97-5-) AC : 5V / A AC 5: V / A DC : V / A DC : V / 5A /.Hz UL 5: B / R Maximal contact load at AC with V: contacts with A each ) Inductive load L/R ms ) Resistive load Operations x ) ) Min. excitation voltage (guaranteed values) without No heat accumulation due to intrinsic heating of other components. Continuous duty %. ELESTA relays GmbH, Heuteilstrasse, CH - 7 Bad Ragaz, Switzerland Fon: + () 5 Fax: + () 5 Copyright / 5
8 SIS sensitive Series - Protective separation between control and load curcuit (leakage and creepage distances >mm) - EN55 type A - Double and reinforced insulation between the contacts - Contact mounting: SIS NO / NC - Small external dimensions - Mean coil power. W - Holding coil power. W - For railway application (EN555) on request.5 ± Ø Contact Data AgCuNi+.-.μm Au Type of contact Single contact with notched crown Rated switching capacity 5VAC A AC 5VA Electr. life AC ( cycles/h) >9 A for ms 5 to 5 /VAC ma to A Switching capacity range* mw to 5W(VA) at C C at C 5..5 ± %. 9 ± % 9.5 ± %. ± %. ± %. ± % ± %. 9 ± 5% A A SISSEN - Basic insulation at 5VAC - Air and creepage distance >mm - Test voltage 5V/5Hz/min - Double or reinforced insulation at 5VAC - Air and creepage distance 5.5mm - Test voltage V/5Hz/min - Double or reinforced insulation at 5VAC - Air and creepage distance >mm - Test voltage V/5Hz/min Test voltage contact open 5V/5Hz/min Creepage resistance CTI 75 Pollution degree >x operations 5Hz typically ms typically ms typically ms typically 5ms Shock resistance ms NO > 7g NC > g NO > 7g (-Hz) NC > g A SCPD A gg/gl (pre-fuse) - C to +7 C Thermal Resistance 55K/W Temperature limit for coil C ca. g RT 7 C/5s UL File E95 Sec. 5 Insulation class IEC - 5VAC Protection class II VDE UL 9 / V none available SIS SEN sensitive coil Contact Lifetime for NO Contacts Operations x DC : V AC :V AC 5: V DC : V Maximal switching characteristics (DIN EN97-5-) AC : 5V / A AC 5: V / A DC : V / A DC : V / 5A /.Hz UL 5: B / R Maximal contact load at AC with V: contacts with A each Operations x ) Inductive load L/R ms ) Resistive load ) ) Min. excitation voltage (guaranteed values) without No heat accumulation due to intrinsic heating of other components. Continuous duty %. Copyright / ELESTA relays GmbH, Heuteilstrasse, CH - 7 Bad Ragaz, Switzerland Fon: + () 5 Fax: + () 5
9 SIS Series - Protective separation between control and load curcuit (leakage and creepage distances >mm) - EN55 type A - Double and reinforced insulation between the contacts - Contact Mounting: SIS NO / NC SIS NO / NC - Small external dimensions - Mean coil power.5 W - Holding coil power.5 W - For railway application (EN555) on request.5 ±....5 ±.... SIS SIS Ø Contact Data Ø AgCuNi+.-.μm Au Type of contact Single contact with notched crown Rated switching capacity 5VAC A AC 5VA Electr. life AC ( cycles/h) >9 A for ms 5 to 5 /VAC ma to A Switching capacity range* mw to 5W(VA) at C C at C ± % ± %.. 5 ± %.. ± %.. 5 ± %.. ± %.. 7 ± % ± 5% A SIS A A SIS - Basic insulation at 5VAC - Air and creepage distance >mm - Test voltage 5V/5Hz/min - Double or reinforced insulation at 5VAC - Air and creepage distance >5.5mm - Test voltage V/5Hz/min - Double or reinforced insulation at 5VAC - Air and creepage distance >mm - Test voltage V/5Hz/min Test voltage contact open 5V/5Hz/min Creepage resistance CTI 75 Pollution degree >x operations 5Hz typically 5ms typically 5ms typically ms typically 5ms Shock resistance ms NO > g NC > g NO > g (-Hz) NC > g A SCPD A gg/gl (pre-fuse) - C to +7 C Thermal Resistance 5K/W Temperature limit for coil C ca. g RT 7 C/5s UL File E95 Sec. 5 Insulation class IEC - 5VAC Protection class II VDE UL 9 / V none available SIS A Contact Lifetime for NO Contacts Operations x DC : V AC :V AC 5: V DC : V Maximal switching characteristics (DIN EN97-5-) AC : 5V / A AC 5: V / A DC : V / A DC : V / 5A /.Hz UL 5: B / R Maximal contact load at AC with V: contacts with A each contacts with A each Operations x ) Inductive load L/R ms ) Resistive load ) ) Min. excitation voltage (guaranteed values) without No heat accumulation due to intrinsic heating of other components. Continuous duty %. ELESTA relays GmbH, Heuteilstrasse, CH - 7 Bad Ragaz, Switzerland Fon: + () 5 Fax: + () 5 Copyright / 7
10 SIS Series - Protective separation between control and load curcuit (leakage and creepage distances >mm) - EN55 type A - Double and reinforced insulation between the contacts - Contact mounting: SIS NO / NC - Small external dimensions - Mean coil power. W - Holding coil power. W - For railway application (EN555) on request.5 ± Contact Data.5 Ø..7.. AgCuNi+.μm Au Type of contact Single contact with notched crown Rated switching capacity 5VAC A AC 5VA Electr. life AC ( cycles/h) >9 A for ms 5 to 5 /VAC ma to A Switching capacity range* mw to 5W(VA) at C C 5 at C ± % ± % ± % ± %. 9.7 ± %..9 5 ± %.. 5 ± % 77.. ± 5% 5 5 A SIS - Basic insulation at 5VAC - Air and creepage distance >mm - Test voltage 5V/5Hz/min - Double or reinforced insulation at 5VAC - Air and creepage distance >5.5mm - Test voltage V/5Hz/min - Double or reinforced insulation at 5VAC - Air and creepage distance >mm - Test voltage V/5Hz/min Test voltage contact open 5V/5Hz/min Creepage resistance CTI 75 Pollution degree >x operations 5Hz typically 5ms typically 5ms typically ms typically 5ms Shock resistance ms NO > g NC > 9g NO > g (-Hz) NC > g A SCPD A gg/gl (pre-fuse) - C to +7 C Thermal Resistance 5K/W Temperature limit for coil C ca. 5g RT 7 C/5s UL File E95 Sec. 5 Insulation class IEC - 5VAC Protection class II VDE UL 9 / V none available A Contact Lifetime for NO Contacts Operations x DC : V AC :V AC 5: V DC : V Maximal switching characteristics (DIN EN97-5-) AC : 5V / A AC 5: V / A DC : V / A DC : V / 5A /.Hz UL 5: B / R Maximal contact load at AC with V: contacts with A each contacts with A each contacts with A each Operations x ) Inductive load L/R ms ) Resistive load ) ) Min. excitation voltage (guaranteed values) without No heat accumulation due to intrinsic heating of other components. Continuous duty %. SIS Copyright / ELESTA relays GmbH, Heuteilstrasse, CH - 7 Bad Ragaz, Switzerland Fon: + () 5 Fax: + () 5
11 SIF Series - Protective separation between coil and contacts (>5.5mm) and contacts side by side (>5.5mm) - EN55 type A - Double and reinforced insulation - SMD arrangement below relay possible - Contact Mounting: SIF NO / NC - Compact height: only.9mm - Mean coil power.7 W - Holding coil power. W - For railway application (EN555) on request Ø * Do not drill when SMD arrangement ** Open breathing hole Contact Data AgCuNi+.μm Au Type of contact Single contact with notched crown Rated switching capacity 5VAC A AC VA Electr. life AC ( cycles/h) approx. A for ms 5 to 5 /VAC ma to A Switching capacity range* mw to W(VA) at C C at C ± % ± % 9. ± % ± % 9. ± %. ± %.7 5 ± %. 7 5 ± 5%.. A SIF A - Double or reinforced insulation at 5VAC - Air and creepage distance >5.5mm - Test voltage V/5Hz/min Test voltage contact open 5V/5Hz/min Creepage resistance CTI 75 Pollution degree >x operations 5Hz typically ms typically 5ms typically.5ms typically 5ms Shock resistance ms NO > 5g NC > g NO > g (-Hz) NC > g Resistance to short circuiting NO A SCPD A gg/gl (pre-fuse) Resistance to short circuiting NC A SCPD A gg/gl (pre-fuse) - C to +7 C Thermal resistance K/W Temperature limit for coil C ca. g 7 C/5s UL File E95 Sec. Insulation class IEC - 5VAC Protection class II VDE UL 9 / V none available SIF Contact Lifetime for NO Contacts Operations x AC 5: V DC : V AC :V DC : V Maximal switching characteristics (DIN EN 97-5-) AC : 5V / A AC 5: V / 5A DC : V / A DC : V / 5A /.Hz UL 5: B / R Maximal contact load at AC with V: contacts with A each contacts with A each Operations x ) Inductive load L/R ms ) Resistive load ) ) Min. excitation voltage (guaranteed values) without No heat accumulation due to intrinsic heating of other components. Continuous duty %. ELESTA relays GmbH, Heuteilstrasse, CH - 7 Bad Ragaz, Switzerland Fon: + () 5 Fax: + () 5 Copyright / 9
12 SIF Series - Protective separation between coil and contacts (>5.5mm) and contacts side by side (>5.5mm) - EN55 type A - Double and reinforced insulation - SMD arrangement below relay possible - Contact mounting: SIF NO / NC - Compact height: only.9mm - Mean coil power. W - Holding coil power. W - For railway application (EN555) on request * * * Ø. *..... * Do not drill when SMD arrangement ** Open breathing hole Contact Data AgCuNi+.μm Au Type of contact Single contact with notched crown Rated switching capacity 5VAC A AC VA Electr. life AC ( cycles/h) approx. A for ms 5 to 5 /VAC ma to A Switching capacity range* mw to W(VA) at C C at C ± % ± %.9 ± %. ± % ± %. ± %. 5 ± %. ± 5% 5 A 5 SIF A - Double or reinforced insulation at 5VAC - Air and creepage distance >5.5mm - Test voltage V/5Hz/min Test voltage contact oopen 5V/5Hz/min Creepage resistance CTI 75 Pollution degree >x operations 5Hz typically ms typically ms typically.5ms typically 5ms Shock resistance ms NO > g NC > g NO > g (-Hz) NC > g Resistance to short circuiting NO A SCPD A gg/gl (pre-fuse) Resistance to short circuiting NC A SCPD A gg/gl (pre-fuse) - C to +7 C Thermal Resistance 7K/W Temperature limit for coil C ca. 5g 7 C/5s UL File E95 Sec. Insulation class IEC - 5VAC Protection class II VDE UL 9 / V none available SIF Contact Lifetime for NO Contacts Operations x AC 5: V DC : V AC :V DC : V Maximal switching characteristics (DIN EN 97-5-) AC : 5V / A AC 5: V / 5A DC : V / A DC : V / 5A /.Hz UL 5: B / R Maximal contact load at AC with V: contacts with A each contacts with A each contacts with.5a each Operations x ) Inductive load L/R ms ) Resistive load ) ) Min. excitation voltage (guaranteed values) without No heat accumulation due to intrinsic heating of other components. Continuous duty %. Copyright / ELESTA relays GmbH, Heuteilstrasse, CH - 7 Bad Ragaz, Switzerland Fon: + () 5 Fax: + () 5
13 SIR Series will be replaced by SGRZK - Protective separation between coil and contacts (leakage and creepage distances >mm); protective separation diagonally between left and right contact side (leakage and creepage distances >5.5mm) - EN55 type B - CO contacts - Mean coil power W - Holding Power.W..7 SIR A A Contact Lifetime for NO Contacts Operations x AC :V AC 5: V AC : V DC : V DC : V Contact Data /.5 Ø AgSnO +.μm Au Type of contact Single contact Rated switching capacity 5VAC A AC VA Electr. life AC ( cycles/h) approx. 5A for ms 5 to 5 /VAC ma to A Switching capacity range* mw to W(VA) at C C at C ± %.5. ± % ± %.5. 7 ± %.. 7 ± %.. ± % 5. ± %.5. ± 5% - Double or reinforced insulation at 5VAC - Air and creepage distance >5.5mm - Test voltage V/5Hz/min - Double or reinforced insulation at 5VAC - Air and creepage distance >mm - Test voltage 5 V/5Hz/min Test voltage contact open 5V/5Hz/min Creepage resistance CTI 55 Pollution degree >x operations 5Hz typically ms typically 5ms typically ms typically ms Shock resistance ms NO > g NC >.5g NO > g (-55Hz) NC > g A SCPD A gg/gl (pre-fuse) - C to +7 C Thermal resistance 5K/W Temperature limit for coil C ca. g 7 C/5s UL File E95 Sec. Insulation class IEC - 5VAC Protection class II VDE UL 9 / V PCB socket, DIN rail socket see page Sealed RT on request Dust resistant with O-Ring Maximal switching characteristics (DIN EN97-5-, Tab. C) AC 5: V / 5A DC : V / A UL 5: C Maximal contact load at AC with V: contacts with A each Current (A)..... Not otf for or new new wd designs gns Voltage () ) Inductive load L/R ms ) Resistive load ) ) Min. excitation voltage (guaranteed values) without No heat accumulation due to intrinsic heating of other components. Continuous duty %. SIR O-ring dust-resistant ELESTA relays GmbH, Heuteilstrasse, CH - 7 Bad Ragaz, Switzerland Fon: + () 5 Fax: + () 5 Copyright /
14 SIR sensitive Series will be replaced by SGRZK - Protective separation between coil and contacts (leakage and creepage distances >mm); protective separation diagonally between left and right contact side (leakage and creepage distances >5.5mm) - EN55 type B - CO contacts - Mean coil power approx..7w - Holding coil power.w - For railway application (EN555) on request Contact Data /.5 Ø AgSnO +.μm Au Type of contact Single contact Rated switching capacity 5VAC A AC VA Electr. life AC ( cycles/h) approx. 5A for ms 5 to 5 /VAC ma to A Switching capacity range* mw to W(VA) at C C at C ± %.5. 5 ± % 9.. ± %.5. 5 ± %.. ± %. 5. ± % 5. 5 ± %.5.5 ± 5% A SIRSEN A - Double or reinforced insulation at 5VAC - Air and creepage distance >5.5mm - Test voltage V/5Hz/min - Double or reinforced insulation at 5VAC - Air and creepage distance >mm - Test voltage 5 V/5Hz/min Test voltage contact open 5V/5Hz/min Creepage resistance CTI 5 Pollution degree >x operations 5Hz typically ms typically 5ms typically ms typically ms Shock resistance ms NO > g NC >.5g NO > g (-55Hz) NC > g A SCPD A gg/gl (pre-fuse) - C to +7 C Thermal Resistance 5K/W Temperature limit for coil C ca. g 7 C/5s UL File E95 Sec. Insulation class IEC - 5VAC Protection class II VDE UL 9 / V PCB socket, DIN rail socket see page Sealed RT on request Dust resistant with O-Ring Contact Lifetime for NO Contacts Operations x Not tfo or new wd design gns AC :V AC 5: V AC : V DC : V DC : V Maximal switching characteristics (DIN EN97-5-, Tab. C) AC 5: V / 5A DC : V / A UL 5: C Maximal contact load at AC with V: contacts with A each Voltage () ) Inductive load L/R ms ) Resistive load Current (A) ) ) Min. excitation voltage (guaranteed values) without No heat accumulation due to intrinsic heating of other components. Continuous duty %. SIR SEN O-ring dust-resistant sensitive coil Copyright / ELESTA relays GmbH, Heuteilstrasse, CH - 7 Bad Ragaz, Switzerland Fon: + () 5 Fax: + () 5
15 SGR Z Series will be replaced by SGRZK - Protective separation between coil and contacts (leakage and creepage distances >mm); protective separation diagonally between left and right contact side (leakage and creepage distances >5.5mm) - EN55 type B - CO contacts - Mean coil power W - Holding coil power.w Contact Data /.5 Ø AgCuNi Type of contact Single contact Rated switching capacity 5VAC A AC VA Electr. life AC ( cycles/h) approx. 5A for ms 5 to 5 /VAC ma to A * ma to A Switching capacity range* mw to 5W(VA) Switching capacity range** mw to 5W(VA) at C C at C ± %.5. ± % ± %.5. 7 ± %.. 7 ± %.. ± % 5.. ± %.5. ± 5% A SGRZ A - Double or reinforced insulation at 5VAC - Air and creepage distance >5.5mm - Test voltage V/5Hz/min - Double or reinforced insulation at 5VAC - Air and creepage distance >mm - Test voltage 5 V/5Hz/min Test voltage contact open 5V/5Hz/min Creepage resistance CTI 55 Pollution degree >5x operations 5Hz typically ms typically 5ms typically ms typically ms Shock resistance ms NO > g NC >.5g NO > g (-55Hz) NC > g A SCPD A gg/gl (pre-fuse) - C to +7 C Thermal resistance 5K/W Temperature limit for coil C ca. g 7 C/5s UL File E95 Sec. Insulation class IEC - 5VAC Protection class II VDE UL 9 / V PCB socket, DIN rail socket see page Sealed RT on request Dust resistant with O-Ring SGRZ AU O-ring dust resistant Contact Lifetime for NO Contacts Operations x DC :V AC :V AC 5:V DC :V Maximal switching characteristics (DIN EN97-5-, Tab. C) AC 5: V / A DC : V / A UL 5: C Maximal contact load at AC with V: contacts with A each Gold contacts with - m layer thickness When switching high voltages and currents the layer of gold is already destroyed after a few switching operations. Once the gold layer is damaged due to the switching of high loads, this contact must not be used more for signal and control current circuits. Then safe contact making is only possible at high loads with the formation of sparks. Operations x..... Not otfo for or new ewd designs gns ) Inductive load L/R ms ) Resistive load ) ) Min. excitation voltage (guaranteed values) without No heat accumulation due to intrinsic heating of other components. Continuous duty %. ELESTA relays GmbH, Heuteilstrasse, CH - 7 Bad Ragaz, Switzerland Fon: + () 5 Fax: + () 5 Copyright /
16 SGR Z sensitive Series will be replaced by SGRZK - Protective separation between coil and contacts (leakage and creepage distances >mm); protective separation diagonally between left and right contact side (leakage and creepage distances >5.5mm) - EN55 type B - CO contacts - Mean coil power.7w - Holding coil power.w Contact Data /.5 Ø AgCuNi Type of contact Single contact Rated switching capacity 5VAC A AC 5VA Electr. life AC ( cycles/h) approx. 5A for ms 5 to 5 /VAC ma to A * ma to A Switching capacity range* mw to 5W(VA) Switching capacity range** mw to 5W(VA) at C C at C ± %.5. 5 ± % 9.. ± %.5. 5 ± %.. ± %. 5. ± % ± %.5.5 ± 5% A SGRZ SEN A - Double or reinforced insulation at 5VAC - Air and creepage distance >5.5mm - Test voltage V/5Hz/min - Double or reinforced insulation at 5VAC - Air and creepage distance >mm - Test voltage 5 V/5Hz/min Test voltage contact open 5V/5Hz/min Creepage resistance CTI 55 Pollution degree >x operations 5Hz typically ms typically 5ms ct typically ms typically ms Shock resistance ms NO > g NC >.5g NO > g (-55Hz) NC > g A SCPD A gg/gl (pre-fuse) - C to +7 C Thermal resistance 5K/W Temperature limit for coil C ca. g 7 C/5s UL File E95 Sec. Insulation class IEC - 5VAC Protection class II VDE UL 9 / V PCB socket, DIN rail socket see page Sealed RT on request Dust resistant with O-Ring SGRZ SEN AU O-ring dust resistant sensitive Spule Contact Lifetime Operations x DC :V AC :V AC 5:V DC :V Maximal switching characteristics (DIN EN97-5-, Tab. C) AC 5: V / A DC : V / A UL 5: C Maximal contact load at AC with V: contacts with A each Gold contacts with - m layer thickness When switching high voltages and currents the layer of gold is already destroyed after a few switching operations. Once the gold layer is damaged due to the switching of high loads, this contact must not be used more for signal and control current circuits. Then safe contact making is only possible at high loads with the formation of sparks. Operations x..... Not otf for forn new ewd designs gns ) Inductive load L/R ms ) Resistive load ) ) Min. excitation voltage (guaranteed values) without No heat accumulation due to intrinsic heating of other components. Continuous duty %. Copyright / ELESTA relays GmbH, Heuteilstrasse, CH - 7 Bad Ragaz, Switzerland Fon: + () 5 Fax: + () 5
17 SGR ZK Series - Protective separation between coil and contacts (leakage and creepage distances >mm); protective separation diagonally between left and right contact side (leakage and creepage distances >5.5mm) - EN55 type B - CO contacts with notched crown - Mean coil power.7w - Holding Power.W Contact Data /.5 Ø Type of contact notched crown Rated switching capacity 5VAC A AC VA Electr. life AC ( cycles/h) approx. 5A for ms 5 to 5 /VAC ma to A Switching capacity range* 5mW to W(VA) at C C at C ± % ± % ± %.5.9 ± %. 9. ± %..5 9 ± % ± %.5. 7 ± 5% A SGRZ A - Double or reinforced insulation at 5VAC - Air and creepage distance >5.5mm - Test voltage V/5Hz/min - Double or reinforced insulation at 5VAC - Air and creepage distance >mm - Test voltage 5 V/5Hz/min Test voltage contact open 5V/5Hz/min Creepage resistance CTI 55 Pollution degree >x operations 5Hz typically ms typically 5ms typically ms typically ms Shock resistance ms NO > g NC >.5g NO > g (-55Hz) NC >.5g Resistance to short circuiting NO A SCPD A gg/gl (pre-fuse) NC A SCPD A gg/gl (pre-fuse) - C to +7 C Thermal resistance 5K/W Temperature limit for coil C ca. g 7 C/5s UL File E95 Sec. Insulation class IEC - 5VAC Protection class II VDE UL 9 / V PCB socket, DIN rail socket see page Various modules on request Contact Lifetime for NO Contacts Operations x AC :V AC 5: V DC : V AC : V DC : V Maximal switching characteristics (DIN EN97-5-, Tab. C) AC 5: V / A DC : V / A UL 5: C Maximal contact load at AC with V: contacts with A each ) Inductive load L/R ms ) Resistive load Operations x ) Max. excitation voltage with contact load: <A ) Min. excitation voltage (guaranteed values) without No heat accumulation due to intrinsic heating of other components. Continuous duty %. SGRZK ELESTA relays GmbH, Heuteilstrasse, CH - 7 Bad Ragaz, Switzerland Fon: + () 5 Fax: + () 5 Copyright / 5
18 SIM Series - PCB Relay with forcibly guided Contacts - Protective separation between coil and contacts (leakage and creepage distances >mm); protective separation diagonally between left and right contact side (leakage and creepage distances >5.5mm) - EN55 type A - Contact mounting: SIM NO / NC - Small external dimensions - Mean coil power.5w - Holding coil power.5w Contact Data Ø AgSnO Type of contact Crest contact Rated switching capacity 5VAC A AC VA Electr. life AC ( cycles/h) approx. A for ms 5 to 5 /VAC ma to A Switching capacity range* mw to W(VA) at C C at C ± % ± %.. 7 ± %.7. ± %.. ± %..9 ± %..7 5 ± 5% ± 5% A SIM A - Double or reinforced insulation at 5VAC - Air and creepage distance >5.5mm - Test voltage V/5Hz/min - Double or reinforced insulation at 5VAC - Air and creepage distance >mm - Test voltage 5 V/5Hz/min Test voltage contact open 5V/5Hz/min Creepage resistance CTI 5 Pollution degree >x operations 5Hz typically ms typically ms typically ms typically ms Shock resistance ms NO > g NC >.5g NO > g (-Hz) NC > g A SCPD A gg/gl (pre-fuse) - C to +7 C Thermal resistance 55K/W Temperature limit for coil C ca. g 7 C/5s UL File E95 Sec. Insulation class IEC - 5VAC Protection class II VDE UL 9 / V none available SIM Contact Lifetime Operations x AC :V DC : V AC 5: V DC : V Maximal switching characteristics (DIN EN97-5-, Tab. C) AC : 5V / A AC 5: V / A DC : / A DC : V / A /.Hz UL 5: C5 / R Voltage () ) Inductive load L/R ms ) Resistive load Current (A) ) ) Min. excitation voltage (guaranteed values) without No heat accumulation due to intrinsic heating of other components. Continuous duty %. Copyright / ELESTA relays GmbH, Heuteilstrasse, CH - 7 Bad Ragaz, Switzerland Fon: + () 5 Fax: + () 5
19 SIM Series - Protective separation between coil and contacts (leakage and creepage distances >mm); protective separation diagonally between left and right contact side (leakage and creepage distances >5.5mm) - EN55 type A - Contact mounting: SIM NO / NC - Small external dimensions - Mean coil power.75w - Holding coil power.w - For railway application (EN 555) on request Ø. Standard Contact Data Ø. KV.5 AgSnO Type of contact Crest contact Rated switching capacity 5VAC A AC VA Electr. life AC ( cycles/h) approx. A for ms 5 to 5 /VAC ma to A Switching capacity range* mw to W(VA) at C C at C ± %.5 5. ± % ± % ± %.. ± %. 5. ± % 5..5 ± %.5. ± 5% Variant : Standard A SIM A Variant : KV A SIM - Basic insulation at 5VAC - Air and creepage distance >mm - Test voltage 5V/5Hz/min - Double or reinforced insulation at 5VAC - Air and creepage distance >5.5mm - Test voltage V/5Hz/min - Double or reinforced insulation at 5VAC - Air and creepage distance >mm - Test voltage 5 V/5Hz/min Test voltage contact oopen 5V/5Hz/min Creepage resistance CTI 5 Pollution degree >x operations 5Hz typically ms typically ms typically ms typically ms Shock resistance ms NO > g NC >.5g NO > g (-Hz) NC > g A SCPD A gg/gl (pre-fuse) - C to +7 C Thermal Resistance 5K/W Temperature limit for coil C ca. 5g 7 C/5s UL File E95 Sec. Insulation class IEC - 5VAC Protection class II VDE UL 9 / V A PCB socket, DIN rail socket see page 9 SIM Contact Lifetime Operations x AC :V DC : V AC 5: V DC : V Maximal switching characteristics (DIN EN97-5-, Tab. C) AC : 5V / A AC 5: V / A DC : V / A DC : V / A /.Hz UL 5: C5 / R Maximal contact load at AC with V: contacts with A each Voltage () ) Inductive load L/R ms ) Resistive load Current (A) ) ) Min. excitation voltage (guaranteed values) without No heat accumulation due to intrinsic heating of other components. Continuous duty %. ELESTA relays GmbH, Heuteilstrasse, CH - 7 Bad Ragaz, Switzerland Fon: + () 5 Fax: + () 5 Copyright / 7
20 SIM Series - Protective separation between coil and contacts (leakage and creepage distances >mm); protective separation diagonally between left and right contact side (leakage and creepage distances >5.5mm) - EN55 type A - Contact mounting: SIM NO / NC SIM NO / NC - Small external dimensions - Mean coil power W - Holding coil power.9w Ø. Contact Data AgSnO Type of contact Crest contact Rated switching capacity 5VAC A AC VA Electr. life AC ( cycles/h) approx. A for ms 5 to 5 /VAC ma to A Switching capacity range* mw to W(VA) at C C at C ± %.5. ± % ± % ± %.. ± %.. ± % 5.. ± %.5 9. ± 5% SIM A A A SIM A - Basic insulation at 5VAC - Air and creepage distance >mm - Test voltage 5V/5Hz/min - Double or reinforced insulation at 5VAC - Air and creepage distance >5.5mm - Test voltage V/5Hz/min - Double or reinforced insulation at 5VAC - Air and creepage distance >mm - Test voltage 5 V/5Hz/min Test voltage contact oopen 5V/5Hz/min Creepage resitance CTI 5 Pollution degree >x operations 5Hz typically ms typically ms typically ms typically ms Shock resistance ms NO > g NC >.5g NO > g (-Hz) NC > g A SCPD A gg/gl (pre-fuse) - C to +7 C Thermal Resistance 5K/W Temperature limit for coil C ca. 5g 7 C/5s UL File E95 Sec. Insulation class IEC - 5VAC Protection class II VDE UL 9 / V PCB socket, DIN rail socket see page 9 SIM Contact Lifetime Operations x AC :V DC : V AC 5: V DC : V Maximal switching characteristics (DIN EN97-5-, Tab. C) AC : 5V / A AC 5: V / A DC : V / A DC : V / A /.Hz UL 5: C5 / R Maximal contact load at AC with V: contacts with A each contacts with A each Voltage () ) Inductive load L/R ms ) Resistive load Current (A) ) ) Min. excitation voltage (guaranteed values) without No heat accumulation due to intrinsic heating of other components. Continuous duty %. Copyright / ELESTA relays GmbH, Heuteilstrasse, CH - 7 Bad Ragaz, Switzerland Fon: + () 5 Fax: + () 5
21 SLR Series - Protective separation between coil/control contacts (>mm) as well as protective separation between the output contacts themselves (>mm) - EN55 type A - Contact mounting: SLR NO / NC SLR NO / NC - Small external dimensions - Mean coil power.w - Holding coil power.w - Coils for railway applications (EN 555) on request Ø Component Side Contact Data AgSnO Type of contact Crest contact Rated switching capacity 5VAC A AC 5VA Electr. life AC ( cycles/h) approx. 5A for ms 5 to 5 /VAC ma to A Switching capacity range* mw to 5W(VA) at C C at C 5.5. ± %.. ± %. 5. ± %.. 5 ± % ± %.. ± %.. ± % ± 5% SLR A A A SLR A - Basic insulation at 5VAC - Air and creepage distance >mm - Test voltage 5V/5Hz/min - Double or reinforced insulation at 5VAC - Air and creepage distance >mm - Test voltage V/5Hz/min - Double or reinforced insulation at 5VAC - Air and creepage distance >mm - Test voltage 5 V/5Hz/min Test voltage contact open 5V/5Hz/min Creepage resistance CTI 5 Pollution degree >x operations 5Hz typically 5ms typically ms typically ms typically ms Shock resistance ms NO > g NC > g NO > 5g (-Hz) NC >.5g A SCPD A gg/gl (pre-fuse) - C to +7 C Thermal Resistance 55K/W Temperature limit for coil C ca. g 7 C/5s UL File E95 Sec. Insulation class IEC - 5VAC Protection class II VDE UL 9 / V none available Contact Lifetime Operations x AC :V DC : V AC 5: V DC : V Maximal switching characteristics (DIN EN97-5-, Tab. C) AC 5: V / 5A DC : V / 7.5A /.Hz UL 5: C / R Maximal contact load at AC with V: contacts with A each contacts with.a each Operations x ) Inductive load L/R ms ) Resistive load ) ) Min. excitation voltage (guaranteed values) without No heat accumulation due to intrinsic heating of other components. Continuous duty %. SLR ELESTA relays GmbH, Heuteilstrasse, CH - 7 Bad Ragaz, Switzerland Fon: + () 5 Fax: + () 5 Copyright / 9
22 SIR Series - Protective separation between coil/control contacts (>mm) as well as protective separation between the output contacts themselves (>mm) - EN55 type A - Contact mounting: SIR NO / NC SIR NO / NC - Small external dimensions - Mean coil power.w - Holding coil power.w - Coils for railway applications (EN 555) on request Contact Data Ø..7 AgSnO Type of contact Crest contact Rated switching capacity 5VAC A AC 5VA Electr. life AC ( cycles/h) approx. 5A for ms 5 to 5 /VAC ma to A Switching capacity range* mw to 5W(VA) at C C at C 5.5. ± %.. ± %. 5. ± %.. 5 ± % ± %.. ± %.. ± % ± 5% A SIR A A SIR A - Basic insulation at 5VAC - Air and creepage distance >mm - Test voltage 5V/5Hz/min - Double or reinforced insulation at 5VAC - Air and creepage distance >mm - Test voltage V/5Hz/min - Double or reinforced insulation at 5VAC - Air and creepage distance >mm - Test voltage 5 V/5Hz/min Test voltage contact oopen 5V/5Hz/min Creepage resistance CTI 5 Pollution degree >x operations 5Hz typically 5ms typically ms typically ms typically ms Shock resistance ms NO > g NC > g NO > 5g (-Hz) NC >.5g A SCPD A gg/gl (pre-fuse) - C to +7 C Thermal resistance 55K/W Temperature limit for coil C ca. g 7 C/5s UL File E95 Sec. Insulation class IEC - 5VAC Protection class II VDE UL 9 / V PCB socket see page Contact Lifetime Operations x AC :V AC 5: V DC : V DC : V Maximal switching characteristics (DIN EN97-5-, Tab. C) AC 5: V / 5A DC : V / 7.5A /.Hz UL 5: C / R Maximal contact load at AC with V: contacts with A each contacts with.a each Operations x ) Inductive load L/R ms ) Resistive load ) ) Min. excitation voltage (guaranteed values) without No heat accumulation due to intrinsic heating of other components. Continuous duty %. SIR Copyright / ELESTA relays GmbH, Heuteilstrasse, CH - 7 Bad Ragaz, Switzerland Fon: + () 5 Fax: + () 5
23 SIR sensitive Series - Protective separation between coil/control contacts (>mm) as well as protective seperation between the output contacts themselves (>mm) - EN55 type A - Contact mounting: SIR NO / NC SIR NO / NC - Small external dimensions - Mean coil power. W - Holding coil power. W - For railway application (EN555) on request Contact Data Ø..7 AgSnO +.μm Au Type of contact Crest Contact Rated switching capacity 5VAC A AC 5VA Electr. life AC ( cycles/h) approx. 5A for ms 5 to 5 /VAC ma to A Switching capacity range* mw to 5W(VA) at C C at C ± %.5. ± % ± % 9.. ± %.5. 9 ± %. 5. ± %. 7.5 ± % 5.. ± 5% SIRSEN SIRSEN A A A A - Basic insulation at 5VAC - Air and creepage distance >mm - Test voltage 5V/5Hz/min - Double or reinforced insulation at 5VAC - Air and creepage distance >mm - Test voltage V/5Hz/min - Double or reinforced insulation at 5VAC - Air and creepage distance >mm - Test voltage 5 V/5Hz/min Test voltage contact oopen 5V/5Hz/min Creepage resitance CTI 5 Pollution degree >x operations 5Hz typically ms typically 5ms typically ms typically ms Shock resitance ms NO > g NC > g NO > 5g (-Hz) NC >.5g A SCPD A gg/gl (pre-fuse) - C to +7 C Thermal Resistance 55K/W Temperature limit for coil C ca. g 7 C/5s UL File E95 Sec. Insulation class IEC - 5VAC Protection class II VDE UL 9 / V PCB socket see page SIR SEN sensitive coil Contact Lifetime Operations x AC :V AC 5: V DC : V DC : V Maximal switching characteristics (DIN EN97-5-, Tab.C) AC 5: V / 5A DC : V / 7.5A /.Hz UL 5: C / R Maximal contact load AC with V: contacts with A each contacts with.a each Operations x ) Inductive load L/R ms ) Resistive load ) ( contacts) ) Min. excitation voltage (guaranteed values) without No heat accumulation due to intrinsic heating of other components. Continuous duty %. ELESTA relays GmbH, Heuteilstrasse, CH - 7 Bad Ragaz, Switzerland Fon: + () 5 Fax: + () 5 Copyright /
24 SIR Power Series - Protective separation between coil/control contacts and output contacts (>mm) and output contacts side by side (>mm) - EN55 type A - Contact mounting: SIRP Control contacts NO / NC Output contacts NO SIRP Control contacts NC Output contacts NO - Inrush current A / continuous current A - Mean coil power.75 W - Holding coil power. W - For railway application (EN555) on request Control Contacts Ø..7 AgSnO +.μm Au Rated switching capacity 5VAC A AC 5VA Electr. life AC ( cycles/h) approx. 5A for ms 5 to 5 /VAC 5mA to A Switching capacity range* mw to 5W(VA) Output Contacts AgSnO Rated switching capacity 5VAC (VAC) A AC VA Electr. life AC ( cycles/h) approx.5 A for ms 5 to 5 ( VAC) ma to A Switching capacity range* mw to W(VA) at C C at C 5 5. ± %. 9 ± %. ± % ± %.5 7 ± % ± %.5 ± %. ± 5% Output Contacts Control Contacts A SIRP A A SIRP - Basic insulation at 5VAC - Air and creepage distance >mm - Test voltage 5V/5Hz/min - Double or reinforced insulation at 5VAC - Air and creepage distance >mm - Test voltage V/5Hz/min - Double or reinforced insulation at 5VAC - Air and creepage distance >mm - Test voltage 5 V/5Hz/min Test voltage contact open 5V/5Hz/min Creepage resistance CTI 5 Pollution degree >x operations 5Hz typically 5ms typically ms typically ms typically ms Shock resistance ms NO > 7g NC > 7g NO > g (-Hz) NC >.5g Resistance to short circuiting control contacts A SCPD A gg/gl (pre-fuse) Resistance to short circuiting output contacts A SCPD A gg/gl (pre-fuse) - C to +7 C Thermal resistance 55K/W Temperature limit for coil C ca. g 7 C/5s UL File E95 Sec. Insulation class IEC - 5VAC Protection class II VDE UL 9 / V PCB socket see page SIR P Power version A Contact Lifetime (output contacts) DC Operations x DC : V DC : V DC : V 5 Contact Lifetime (output contacts) AC Operations x AC : V AC : V AC : V AC 5: V AC : V 5 Maximal contact load AC with V: contacts with A each Operations x ) Inductive load L/R ms ) Resistive load ) Max. excitation voltage with contact load: ) Min. excitation voltage (guaranteed values) without Copyright / ELESTA relays GmbH, Heuteilstrasse, CH - 7 Bad Ragaz, Switzerland Fon: + () 5 Fax: + () 5
25 SIR Series - Protective separation between coil/control contacts and output contacts (>mm) as well as protective separation between the output contacts themselves (>mm) - EN55 type A - Contact mounting: SIR NO / NC SIR NO / NC SIR5 5NO / NC - Small external dimensions - Mean coil power.75 W - Holding coil power. W - For railway application (EN555) on request Ø..9 Contacts Data AgSnO +.μm Au Type of contact Crest contact Rated switching capacity 5VAC A AC 5VA Electr. life AC ( cycles/h) approx. 5A for ms 5 to 5 /VAC ma to A Switching capacity range* mw to 5W(VA) at C C at C ± %. 5. ± %.. 9 ± %.. ± %..5 7 ± % ± %..5 ± % 77.. ± 5% 5 5 SIR 5 5 SIR 5 5 SIR5 A A A A A A - Basic insulation at 5VAC - Air and creepage distance >mm - Test voltage 5V/5Hz/min - Double or reinforced insulation at 5VAC - Air and creepage distance >mm - Test voltage V/5Hz/min - Double or reinforced insulation at 5VAC - Air and creepage distance >mm - Test voltage 5 V/5Hz/min Test voltage contact open 5V/5Hz/min Creepage resistance CTI 5 Pollution degree >x operations 5Hz typically 5ms typically ms typically ms typically ms Shock resistance ms NO > g NC > g NO > 5g (-Hz) NC > g A SCPD A gg/gl (pre-fuse) - C to +7 C Thermal Resistance 55K/W Temperature limit for coil C ca. 5g 7 C/5s UL File E95 Sec. Insulation class IEC - 5VAC Protection class II VDE UL 9 / V PCB socket see page SIR Contact Lifetime Operations x AC :V AC 5: V DC : V DC : V Max. switching characteristics (DIN EN 97-5-, Tab. C): AC 5: V / 5A DC : V / 7.5A /.Hz UL 5: C / R Maximal contact load at AC with V: contacts with A each contacts with.a each contacts with 7.A each 5 contacts with A each Current (A) Voltage () ) Inductive load L/R ms ) Resistive load ) ) Min. excitation voltage (guaranteed values) without No heat accumulation due to intrinsic heating of other components. Continuous duty %. ELESTA relays GmbH, Heuteilstrasse, CH - 7 Bad Ragaz, Switzerland Fon: + () 5 Fax: + () 5 Copyright /
26 SIR sensitive Series - Protective separation between coil/control contacts and output contacts (>mm) as well as protective separation between the output contacts themselves (>mm) - EN55 type A - Contact mounting: SIR NO / NC SIR NO / NC SIR5 5NO / NC - Small external dimensions - Mean coil power.5 W - Holding coil power. W - For railway application (EN555) on request Ø..9 Contacts Data AgSnO +.μm Au Type of contact Crest contact Rated switching capacity 5VAC A AC 5VA Electr. life AC ( cycles/h) approx. 5A for ms 5 to 5 /VAC ma to A Switching capacity range* mw to 5W(VA) at C C at C ± %.5. 7 ± % ± % 9.. ± % ± %.. 5 ± %.. ± % ± 5% 5 5 SIRSEN 5 5 SIRSEN 5 5 SIR5SEN A A A A A A - Basic insulation at 5VAC - Air and creepage distance >mm - Test voltage 5V/5Hz/min - Double or reinforced insulation at 5VAC - Air and creepage distance >mm - Test voltage V/5Hz/min - Double or reinforced insulation at 5VAC - Air and creepage distance >mm - Test voltage 5 V/5Hz/min Test voltage contact oopen 5V/5Hz/min Creepage resitance CTI 5 Pollution degree >x operations 5Hz typically ms typically 5ms typically ms typically ms Shock resitance ms NO > g NC > g NO > 5g (-Hz) NC > g A SCPD A gg/gl (pre-fuse) - C to +7 C Thermal Resistance 55K/W Temperature limit for coil C ca. 5g 7 C/5s UL File E95 Sec. Insulation class IEC - 5VAC Protection class II VDE UL 9 / V PCB socket see page SIR SEN Sensitive coil Contact Lifetime Operations x AC :V AC 5: V DC : V DC : V Max. switching characteristics (DIN EN 97-5-, Tab. C): AC 5: V / 5A DC : V / 7.5A /.Hz UL 5: C / R Maximal contact load at AC with V: contacts with A each contacts with.a each contacts with 7.A each 5 contacts with A each Current (A) Voltage () ) Inductive load L/R ms ) Resistive load ) ( contacts) ) Min. excitation voltage (guaranteed values) without No heat accumulation due to intrinsic heating of other components. Continuous duty %. Copyright / ELESTA relays GmbH, Heuteilstrasse, CH - 7 Bad Ragaz, Switzerland Fon: + () 5 Fax: + () 5
Elesta Elektrotechnik AG industry relays and accessories
Elesta Elektrotechnik AG industry relays and accessories edition 003 table of contents SKR-industry relay 4 SKR-screw socket with accessories 4 SFR-industry relay 6 SFR-screw socket with accessories 7
More information48.12. 2 pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2,000 500 0.37 8/0.65/0.
48 Series - Relay interface modules 8 A Features 48.12 2 Pole Safety relay interface modules, 15.8 mm wide 48.12-2 Pole 8 A (screw terminal) DC sensitive coils Relay with forcibly guided contacts according
More information1 POLE - 16A 80A Inrush type. (b) Contact configuration A : 1 form A (SPST-NO) C : 1 form C (SPDT) (standard type "K" only)
FTR-K1 SERIES POWER RELAY 1 POLE - 16A 80A Inrush type FTR-K1 Series FEATURES Peak 80A inrush current (1 form A type) Low profile (height: 15.7mm) HIGH INSULATION Insulation distance (between coil and
More information40 Series - Miniature PCB/Plug-in relays 8-10 - 16 A. Features 40.31 40.51 40.52
Features 40.31 40.51 40.52 1 & 2 Pole relay range 40.31-1 Pole 10 A (3.5 mm pin pitch) 40.51-1 Pole 10 A (5 mm pin pitch) 40.52-2 Pole 8 A (5 mm pin pitch) PCB mount - direct or via PCB socket 35 mm rail
More informationPluggable interface relays CR-P Pcb relays
2CDC 293 034 F0004 1 2 4 3 Features 9 different supply s: DC versions: 12 V, 24 V, 48 V, 110 V AC versions: 24 V, 48 V, 110 V, 120 V, 230 V Output contacts: 1 c/o (16 A) or 2 c/o (8 A) Cadmium-free contact
More informationGoodsky Technical Data. Contact Details
Goodsky Technical Data The following page(s) are extracted from multi-page Goodsky product catalogues or CDROMs and any page number shown is relevant to the original document. The PDF sheets here may have
More informationSKR - industry relay
SKR - industry relay the universal relay SKR the time module STM the socket The strengths of the SKR industry relay lie in the mature and thoughtout construction. Over-average contact safety and life time,
More information48 SERIES Relay interface modules 10 A
48 Relay interface modules 10 A 1 CO relay interface modules, mm wide Ideal interface for PLC and electronic systems Type 48.P3 1 CO 10 A s Type 48.31 1 CO 10 A s AC coils or DC sensitive coils Supply
More informationDEK-REL- 24/1/SEN. Extract from the online catalog. Order No.: 2964050
Extract from the online catalog DEK-REL- 24/1/SEN Order No.: 2964050 Relay terminal block for sensor, with soldered-in miniature relays, contact (AgNi+Au): small to medium loads, 1 N/O contact, input voltage
More information49 Series - Relay interface modules 8-10 - 16 A. Features
Features 1 & 2 Pole relay interface modules 5 µm Gold plate contacts for low level switching capability 49.31-50x0-1 Pole 10 A (screw terminal) 49.52-50x0-2 Pole 8 A (screw terminal) 49.72-50x0-2 Pole
More information0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N
55 Series - General purpose relays 7-10 A Features 55.12 55.13 55.14 Printed circuit mount, general purpose 2, 3 & 4 Pole relays 55.12-2 Pole 10 A 55.13-3 Pole 10 A 55.14-4 Pole 7 A AC coils & DC coils
More informationRY2 miniature industrial relays
6 RY2 Relays of general application For plug-in sockets, 35 mm rail mount acc. to PN-EN 60715 or on panel mounting Flat insert connectors - faston x 0,5 mm Recognitions, certifications, directives: RoHS,
More information2 POLES - 5A LOW PROFILE TYPE
FTR-K1 SERIES POWER RELAY 2 POLES - 5A LOW PROFILE TYPE FTR-F1 Series FEATURES Low profile (height: 16.5mm) DPST/DPDT 5A, TV-3 rating available High insulation (due to its reinforced insulation construction)
More information38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A
38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit EMR Electromechanical Relays
More information38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A
38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A 38 SERIES Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit EMR Electromechanical
More informationSPST-NO SPDT DPST-NO DPDT
PCB Relay Next-generation PCB Relay Available in 2 Models Low profile:. mm max. in height Contains no lead inside and features cadmium-free contacts ensuring environment-friendly use. Conforms to VDE0
More information1 POLE - 16A 80A Inrush type. (a) Relay type FTR-K1 : FTR-K1-Series
FTR-K1 SERIES POWER RELAY 1 POLE - 16A 80A Inrush type FTR-K1 Series FEATURES Peak 80A inrush current (1 form A type) Low profile (height: 15.7mm) High insulation Insulation distance (between coil and
More information34 Series - Slim electromechanical PCB relays 6 A. Features SERIES 34.51
34 Series - Slim electromechanical PCB relays 6 34 SERIES Features 34.51 Ultra-slim 1 Pole - 6 relay Printed circuit mount - direct or via PCB socket 35 mm rail mount - via screw, screwless or push-in
More informationElectronic timer CT-VBS.17+18 OFF-delayed without auxiliary voltage, for DC contactors Data sheet
Characteristics Single-function OFF-delay timer for DC contactors, without auxiliary voltage Width.5 mm CDC 5 6 F3 Approvals A culus E CCC CT-VBS a Circuit diagram b Marker label Marks a CE b C-Tick Order
More informationE-STOP relays, safety gate monitors
Unit features Safety features Gertebild ][Bildunterschrift_NOT_Sch.tuer_Licht Safety relay for monitoring E-STOP pushbuttons, safety gates and light beam devices Approvals Gertemerkmale Positive-guided
More informationSILENT POWER RELAY. FTR-H3 Series. 1 POLE - 78A/120A Inrush Current Type FTR-K1 SERIES FEATURES
FTR-K1 SERIES SILENT POWER RELAY 1 POLE - 78A/120A Inrush Current Type FTR-H3 Series FEATURES Pin compatible with widely used VS and FTR-H1 series power relays Silent relay with patented unique U-shape
More information1 POLE - 8A Medium Load Control
POWER RELAY 1 POLE - 8A Medium Load Control JS Series FEATURES UL class B (130 C) coil wire insulation 1 form A (SPST-NO) or 1 form C (SPDT) contact Low profile and space saving - Height: 12.5 mm - Mounting
More informationFP2 Relay. The Best Relaytion
The Best Relaytion 2 pole telecom / signal relay Through Hole Type (THT) Polarized. Relay types: non-latching with1 coil latching with 1 coil latching with 2 coils Features Telecom / signal relay (dry
More informationYour Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592. * see variants. Applications.
Safety Technique SAFEMASTER Emergency Stop Module BG 5924, IP 5924 Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592 BG 5924 IP 5924 Product Description
More information1 POLE 5 A (CADMIUM FREE CONTACTS TYPE) NY SERIES
POWER RELAY 1 POLE 5 A (CADMIUM FREE CONTACTS TYPE) NY SERIES RoHS compliant FEATURES Ultra slim type with 5 mm thickness Good for high density mounting Low power consumption and high sensitivity Nominal
More informationType: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated. Ordering information
Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated Ordering information Connection technique Description Description Rated operational current Screw terminals 3 pole AC
More informationThe Best Relaytion. Reed Relays. 108-98011 Rev. B EC-JM00-0009-03 ECOC: JM10 1. Aug. 04
The Best Relaytion Reed Relays 108-98011 Rev. B EC-JM00-0009-03 ECOC: JM10 1. Aug. 04 1 and 2 pole relays non-polarized, non-latching Features Direct coil control with TTL-signals possible Highly reliable
More informationDATA SHEET COMPACT AND LIGHTWEIGHT, SMALL MOUNTING SIZE, HIGH BREAKDOWN VOLTAGE
DATA SHEET MINIATURE SIGNAL RELAY EC SERIES COMPACT AND LIGHTWEIGHT, SMALL MOUNTING SIZE, HIGH BREAKDOWN VOLTAGE DESCRIPTI The EC series has reduced mounting space but sustained high-performance of NEC
More informationSafety technique. Emergency stop module BO 5988 safemaster
Safety technique Emergency stop module BO 5988 safemaster 0221562 Function diagram Pushbutton on Mains or emergencystop () K1 According to EC Directive for machines 98/37/EG According to IEC/E 60204-1
More informationRELAYS Solar Energy Systems
RELAYS Solar Energy Systems FUJITSU COMPONENTS CONTENTS Fujitsu relays for solar applications DC voltage versions - AC voltage versions - Latching versions RELAY PRODUCT LINE UP - SOLAR ENERGY SYSTEMS
More informationPCB Relay. LED indicator G2R-1A3-SN G2R-13-SN --- --- contact) LED indicator and diode DC G2R-1A3-SND G2R-13-SND --- ---
PCB Relay A Power Relay for a Variety of Purposes with Various Models Conforms to VDE045 (VDE approval: C2 insulation grade), UL8, CSA22.2, SEV, SEMKO. Meets VDE0700 requirements for household products
More information1 POLE - 16A / Inrush 120A relay. (a) Relay type FTR-K1 : FTR-K1 Series (b) Contact configuration A : 1 form A C : 1 form C
FTR-K1 SERIES POWER RELAY 1 POLE - 16A / Inrush 120A relay FTR-K1-KS Series FEATURES 1 pole 16A, 1 form A or 1 form C Peak inrush current 120A / TV-8 Coil power 400mW High insulation in small package (between
More informationPOWER RELAY. FTR-K1-KS Series. 1 POLE - 16A / Inrush 120A relay FTR-K1 SERIES FEATURES
POWER RELAY POLE - 6A / Inrush 20A relay FTR-K-KS Series FTR-K SERIES FEATURES pole 6A, form A or form C Peak inrush current 20A / TV-8 Coil power 400mW High insulation in small package (between coil and
More information38 SERIES. Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.
38 Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A 38 Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit 6.2 mm wide EMR - DC, AC or AC/DC
More informationSafety automation solutions
Operating principle, characteristics Preventa safety s types XPS AV,, For and switch monitoring Operating principle Safety s XPS AV, and are used for monitoring circuits conforming to standards EN/ISO
More informationElectronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact
Data sheet Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact The CT-AHD.12 is an electronic time relay with OFF-delay. It is from the CT-D range. With their MDRC profile and a width of only
More informationThree-phase monitoring relay CM-PFE
Data sheet Three-phase monitoring relay CM-PFE The CM-PFE is a three-phase monitoring relay that monitors the phase parameter phase sequence and phase failure in three-phase mains. 2CDC 251 005 S0012 Characteristics
More informationOptocoupler, Phototransistor Output, AC Input
Optocoupler, Phototransistor Output, AC Input DESCRIPTION The SFH62A (DIP) and SFH626 (SMD) feature a high current transfer ratio, low coupling capacitance and high isolation voltage. These couplers have
More informationPositive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous
Safety relay for monitoring E-STOP pushbuttons. Approvals Unit features Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous 1 auxiliary contact (N/C), instantaneous Safe separation of
More informationPOWER RELAY. JV Series. 1 POLE - 5A/10A Medium Load Control FTR-K1 SERIES FEATURES
FTR-K1 SERIES POWER RELAY 1 POLE - 5A/10A Medium Load Control JV Series FEATURES UL, CSA, VDE, SEMKO, CQC recognized UL class B (130 C) wire class Low profile and space saving - Height: 12.5 mm - Mounting
More informationThroughbeam photoelectric sensors. Dimensioned drawing. Electrical connection
Specifications and description Leuze electronic LS 78 Throughbeam photoelectric sensors Dimensioned drawing 180m 10-30 V DC! Voltage range from 12 30VDC with NPN, PNP and/or relay outputs! Light/dark switching!
More informationMasterINTERFACE 39 Series - Relay interface modules
MasterINTERFACE 39 Series - Relay interface modules Common features Space saving 6.2 mm wide Connections for 16-way jumper link Integral coil indication and protection circuit Secure retention and easy
More informationRT series Miniature Printed Circuit Board Relays, Sockets and Accessories
s RT series Miniature Printed Circuit oard Relays, Sockets and ccessories pplied Coil Voltage (% of rated nom.) RT series (DC Coil) 6 mp PC oard Miniature Relay Meets VDE 0mm Spacing, KV Dielectric File
More information1 POLE - 5A SLIM POWER RELAY
POWER RELAY POLE - A SLIM POWER RELAY FTR-MY Series RoHS compliant FEATURES Width mm, height mm,(% smaller than NY series) area mm, super slim, low power, compact and light weight.gr. Nominal power: mw
More informationSZR-LY Series. General Purpose Power Relay WARNING WARNING. Sensing and Control
Power Relay FEATURES Small package design ARC barrier equipped Silver Cadium Oxide contact High dielectric strength (,800 Vac) High reliability and long life Ultra-high sensitivity with quick response
More informationType: EASY719 DC RC Article No.: 274119. Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description
Type: EASY719 DC RC Article.: 274119 Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC Description 12 digital inputs (4 inputs available as analog inputs) 6 relay outputs LCD display
More informationSPST-NO SPDT DPST-NO DPDT
PCB Relay A Power Relay for a Variety of Purposes with Various Models Conforms to VDE (EN680-), UL08, CSA22.2. Meets EN6033- requirements for household products. Clearance and creepage distance: 8 mm/8
More informationType Sealing Poles Contacts Rated voltage Model Standard d Flux-tight 4 poles oes 3PST-NO, SPST-NC 24 VDC G7SA-3A1B 3PST-NO, 3PST-NC
Safety Relay Slim Safety Relays Conforming to EN Standards The forcibly guided contact in the assures safe operation (EN50205 Class A, approved by VDE.) Ideal for use in safety circuits in press machinery,
More information60 Series - General purpose relays 6-10 A. Features 60.12 60.13
Features 60.12 60.13 Plug-in mount 10 A General purpose relay 2 & 3 pole changeover contacts Cadmium Free contacts (preferred version) AC coils & DC coils UL Listing (certain relay/socket combinations)
More informationReed V23100-V4 Relay. AXICOM Telecom-, Signal and RF Relays. AXICOM Telecom-, Signal and RF Relays. Reed V23100-V4 Relay
AXICOM AXICOM 108-98011 Nov. 07 Rev. C ECOC: JM10 Disclaimer While Tyco Electronics has made every reasonable effort to ensure the accuracy of the information in this datasheet, Tyco Electronics does not
More information1 Form A Solid State Relay
Form A Solid State Relay VOAT, VOAABTR FEATURES 9 S S DC S' 3 S' High speed SSR - t on /t off < 8 μs Maximum R ON. Isolation test voltage 3 V RMS Load voltage V Load current A DC configuration DIP- package
More informationE-STOP relays, safety gate monitors
Unit features Safety features gang engertebild ][Bildunterschrift_NOT_Sch.tuer_Licht Safety relay for monitoring E-STOP pushbuttons, safety gates and light beam devices Approvals Gertemerkmale Positive-guided
More informationRM4TG20 three-phase network control relay RM4-T - range 200..500 V
Characteristics three-phase network control relay RM4-T - range 200..500 V Complementary [Us] rated supply voltage Output contacts Setting accuracy of time delay Delay at power up Measuring cycle Marking
More informationType: DILM50(230V50HZ,240V60HZ) Article No.: 277830
Type: DILM50(230V50HZ,240V60HZ) Article No.: 277830 Ordering information Rated operational current AC 3 400 V I e A 50 Max. rating for three phase motors, 50 60 Hz AC 3 230 V Max. rating for three phase
More information1a/1c 5A/10A small power relays
VDE a/c A/A small power relays RELAYS RoHS compliant FEATURES High electrical noise immunity High switching capacity in a compact package High sensitivity: mw (a), mw (c) High surge voltage:, V between
More informationType: DILM9 10(24VDC) Article No.: 276705
Type: DILM9 10(24VDC) Article No.: 276705 Ordering information Rated operational current AC 3 400 V I e A 9 Max. rating for three phase motors, 50 60 Hz AC 3 230 V Max. rating for three phase motors, 50
More informationE-STOP relays, safety gate monitors
Unit features Safety features Gertebild ][Bildunterschrift Safety relay for monitoring E-STOP pushbuttons and safety gates. Approvals Gertemerkmale Positive-guided relay outputs: 3 safety contacts (N/O),
More informationLC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A - 220 V AC coil
Product data sheet Characteristics LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 -
More information(e) Enclosure B : Flux proof type, RTII C : Plastic sealed type (with tape), RTIII K : Plastic sealed type, RTIII
Non-promotional not for new designs FTR-K1 SERIES POWER RELAY 1 POLE - 10A VS Series FEATURES UL, CSA, VDE, SEV, SEMKO, CQC recognized TV-5 is available Working class: C UL class B (130 C) coil wire insulation
More informationSTEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: 2868567. DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase
Extract from the online catalog STEP-PS/1AC/12DC/1.5 Order No.: 2868567 DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase Commercial data EAN 4046356292924 Pack 1 pcs. Customs tariff
More informationType: DILM32 10(24V50HZ) Article No.: 277247
Type: DILM32 10(24V50HZ) Article No.: 277247 Ordering information Rated operational current AC 3 400 V I e A 32 Max. rating for three phase motors, 50 60 Hz AC 3 230 V Max. rating for three phase motors,
More informationOptocoupler, Phototransistor Output, with Base Connection, 300 V BV CEO
SFH64 Optocoupler, Phototransistor Output, with Base Connection, 3 V BV CEO i1794-3 DESCRIPTION The SFH64 is an optocoupler with very high BV CER, a minimum of 3 V. It is intended for telecommunications
More informationContact expander modules
Gertebild ][Bildunterschrift Kontakterweiterungen Contact expansion module for increasing the number of available contacts Approvals Zulassungen Unit features Gertemerkmale Positive-guided relay outputs:
More informationControl Devices Catalogue. Control Devices. Preferred and Standard Products
Control Devices Catalogue Control Devices Preferred and Standard Products KOP.J Timer Electronic 22.5 mm Characteristics Mounting KOP.J 22.5 mm mono or multifunction high immunity to interference surface
More informationThermal-Magnetic Circuit Breaker 3120-...-M1-..
Thermal-Magnetic Circuit Breaker -...-M-.. Description Single or two pole rocker switch/thermal-magnetic circuit breaker with trip-free mechanism (S-type TM CBE to EN 34). The addition of a magnetic tripping
More informationE-STOP relays, safety gate monitors
Gertebild ][Bildunterschrift Safety relay for monitoring E-STOP pushbuttons and safety gates. Unit features Gertemerkmale Positive-guided relay outputs: 2 safety contacts (N/O), instantaneous Connection
More informationCQM1-SF200/CS1W-SF200
Safety Relay Unit ( I/O Unit Type) CQM1-SF200/CS1W-SF200 CSM_CQM1-SF200_CS1W-SF200_DS_E_2_1 A Safety Relay Unit That Functions as a I/O Unit. Less Installation Space and Wiring Required. Safety Relay Unit
More informationMagnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...
Magnetic and Hydraulic-Magnetic Circuit Breaker 840-G2... Description Single, two and three pole magnetic circuit breakers with trip-free mechanism and push/pull on/off manual actuation. A choice of fast
More informationHERZ-Thermal Actuators
HERZ-Thermal Actuators Data Sheet 7708-7990, Issue 1011 Dimensions in mm 1 7710 00 1 7710 01 1 7711 18 1 7710 80 1 7710 81 1 7711 80 1 7711 81 1 7990 00 1 7980 00 1 7708 11 1 7708 10 1 7708 23 1 7709 01
More informationCompactLogix Power Supplies Specifications
Technical Data CompactLogix Power Supplies Specifications 1768 CompactLogix Power Supplies Catalog Numbers 1768-PA3, 1768-PB3 1769 Compact I/O Power Supplies Catalog Numbers 1769-PA2, 1769-PB2, 1769-PA4,
More informationAXICOM Telecom-, Signal and RF Relays. Cradle Relay S V23054 / V23062. 108-98014 Nov. 07 Rev. C ECOC: JM10
Cradle Relay S V23054 / V23062 108-98014 Nov. 07 Rev. C ECOC: JM10 Disclaimer While Tyco Electronics has made every reasonable effort to ensure the accuracy of the information in this datasheet, Tyco Electronics
More informationRoHS APPROVAL SHEET. ituner 12V/6.6A SERIES NO. (E17) EA10953A. ( ) Edac Power Electronics (Suzhou) Co., Ltd. 59 No.59, Chang Sheng Road, Sheng Pu,
APPROVAL SHEET CUSTOMER ituner CUSTOMER P/N DESCRIPTION EDAC MODEL 12V/6.6A SERIES NO. (E17) EA10953A DATE 2010-06-22 REVISION 0 APPROVED DESIGN PREPARE RoHS CONCLUSION APPROVED CONDITON CUSTOMER S APP
More informationContact expansion modules
Gertebild ][Bildunterschrift Kontakterweiterungen Contact for increasing the number of available contacts Approvals Zulassungen Unit features Gertemerkmale Positive-guided relay outputs: 4 safety contacts
More informationMasterINTERFACE 39 Series - Relay interface modules
MasterINTERFACE 39 Series - 39 Common features Space saving 6.2 mm wide Connections for 16-way jumper link Integral coil indication and protection circuit Secure retention and easy ejection by plastic
More informationCONFIGURABLE SAFETY RELAYS
MSI-m/R, MSI-mx/Rx Configurable MSI Safety Relay with function for efficient material flow in a packaging application Special features Sequential or Parallel with automatic mode detection MSI-mx for separate
More informationHSP GmbH Zum Handwerkerhof 2 90530 Wendelstein Tel. 09129 / 2852-0 Fax: 09129 / 2852-11 Web: www.hsshsp.de EMAIL: HSP@hsshsp.de NTG-3000.
NTG-3000 Transducer Data Sheet Document Version 2.8 Page 1 of 10 Versions / Revisions: Document Creation Author Description version date 2.0 2012-07-25 P. Compensis First official version 2.1 2012-08-24
More informationNumber of poles 1-pole 2-pole Minimum Enclosure Contact. G2R-1AZ G2R-1Z DC Fully sealed G2R-1AZ4 G2R-1Z4 G2R-1A-E G2R-1-E
PCB Power elay The Best Seller eneral purpose power elays of single-pole0 A and double-pole A. Safety-oriented design with dielectric strength of,000 V between coil and contacts, and surge resistance of
More information2 POLES 1 to 2 A (FOR SIGNAL SWITCHING)
MINIATURE RELAY 2 POLES 1 to 2 A (FOR SIGNAL SWITCHING) RY SERIES FEATURES Ultra high sensitivity UL, CSA recognized Conforms to FCC rules and regulations Part 68 Surge strength 1,500 V High dielectric
More informationCurrent valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw
4 937 DESIO Current valve for AC 24 V pulse/pause control of electrical loads up to 30 kw SEA45.1 Use The current valve is used for the control of electric heating elements in heating, ventilation and
More informationNX safety stand-alone
NX-S@ NX safety stand-alone stand-alone into machine automation Expandable safety system up to 32 safety connections or 63 standard connections controller flexible system lets your freely mix safety I/O
More informationG7SA. Ordering Information. Slim Plug-In Safety Relay. Slim Safety Relay for Machine Control. H Slim body only 13 x 24 x 50 mm
Slim Plug-In Safety Relay Slim Safety Relay for Machine Control H Slim body only 13 x 24 x 50 mm (six poles) H Four-pole and six-pole models are available H Terminal arrangement simplifies PCB pattern
More informationNF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals
Technical Datasheet 1SBC101433D0201 28/03/11 NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals NF(Z) contactor relays are used for switching auxiliary and control circuits.
More informationRelays and Timers Specifications Bulletin Number 700
Technical Data Relays and Timers Specifications Bulletin Number 700 Topic Page General Purpose Relays 2 Timing Relays 41 NEMA Industrial Relays 81 IEC Control Relays 93 Solid State Relays 109 Additional
More informationw BREAKING CAPACITY W EMPLOYMENT 1) Locking function description
Relaiskatalog_E:MODUL2000.QXD 18.08.2009 13:18 Uhr Seite 14 INTERFACE RELAYS XT 14 W INTERFACE PLUG-IN RELAYS XT 1 pole 16 A, 2 pole 8 A, 1 CO contact or 2 CO contacts DC- or AC coil, sensitive coil 400mW
More informationABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.
1SR 430 824 F9300 Features Monitoring of three-phase mains for phase sequence and failure Powered by the measuring circuit 2 c/o (SPDT) contacts 1 LED for status indication Approvals R: yellow LED - relay
More information1 Form A Solid State Relay
1 Form A Solid State Relay Vishay Semiconductors DIP i1791- SMD DESCRIPTION Vishay solid state relays (SSRs) are miniature, optically coupled relays with high-voltage MOSFET outputs. The LH1518 relays
More informationE-STOP relays, safety gate monitors
Gertebild ][Bildunterschrift Safety relay for monitoring E-STOP pushbuttons and safety gates. Approvals Unit features Gertemerkmale Positive-guided relay outputs: 2 safety contacts (N/O), instantaneous
More informationInstallation Contactors. Technical Catalogue. Type ESB. abb. ABB STOTZ-KONTAKT GmbH 1 2CDC 103002 C0201
Technical Catalogue Installation Contactors Type ESB abb ABB STOTZ-KONTAKT GmbH 1 CDC 10300 C001 ABB STOTZ-KONTAKT GmbH CDC 10300 C001 Low Voltage Products and Systems We ensure safety and comfort for
More informationPCB transformers. Short circuit proof PCB transformer VB. General Data. Advantages. Applications. Circuit diagram. Standards & 1 Certifications W v
Short circuit PCB transformer General Data Rated input 230 Vac Rated output 6-2 x 24 Vac Rated power 0.35-3.2 VA Insulation class B Maximum ambient temperature 70 C Efficiency up to 58 % Degree of protection
More informationFeatures. Applications. Truth Table. Close
ASSR-8, ASSR-9 and ASSR-8 Form A, Solid State Relay (Photo MOSFET) (0V/0.A/0Ω) Data Sheet Description The ASSR-XX Series consists of an AlGaAs infrared light-emitting diode (LED) input stage optically
More informationVoltage monitoring relays CM-ESS.M For single-phase AC/DC voltages
Data sheet Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages The CM-ESS.M is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of
More informationTrip circuit supervision relay. Type RXTCS
Trip circuit supervision relay Type RXTCS ABB a global technology leader ABB is a global leader in Power and Automation technologies that enable utility and industry customers to improve performance while
More informationAZ420 MINIATURE GENERAL PURPOSE RELAY
MINIATURE GENERAL PURPOSE RELAY FEATURES Rugged construction for high reliability Life expectancy greater than 0 million operations DC coils to 11 V Power consumption as low as 2 mw per pole available
More informationPCB Relays Twin Relays
Powertrain Systems Chassis Systems Safety Security Body Driver Information Convenience Description Features - Two separate systems - Lamp applications - Extremely space saving double relay Typical applications
More informationDISCONTINUED (1998) FBR46 SERIES. MINIATURE RELAY 2 POLES 1 to 2 A (FOR SIGNAL SWITCHING) RoHS compliant FEATURES
MINIATURE RELAY 2 POLES 1 to 2 A (FOR SIGNAL SWITCHING) FBR46 SERIES RoHS compliant FEATURES Miniature size About 50% smaller in volume compared with the FBR240 series used mainly in communication equipment.
More informationDS 600. A contact free flux gate based current measurement sensor 600A rms
DS 600 A contact free flux gate based current measurement sensor 600A rms DS 600 is member of the small housing sensor family. The family includes a 200A and a 600A version. 600A rms - 900A peak Maximum
More informationCONFIGURABLE SAFETY RELAYS
MSI-s/R, MSI-sx/Rx Configurable MSI provide important functions for the efficient flow of automated production processes Special features Combined guarding types by connecting up to 4 AOPDs Additional
More informationElectro-pneumatic control valves
Electropneumatic control valves 7 Miniature solenoid valves for alternating current Conform to the Low Voltage Directive or mounting on subbase or footprint in accordance with CNOMO recoendation E 066120N
More informationAF09-30-22-.. / AF09Z-30-22-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals
Technical Datasheet 1SBC101403D0201 24/03/11 AF09-30-22-.. / AF09Z-30-22-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals AF09(Z) contactors are used for controlling power circuits
More informationReyrolle Protection Devices. 7PG17 - XR Intertripping, Interposing, Supervision and Special Purpose Relays. Answers for energy
Reyrolle Protection Devices 7PG17 - XR Intertripping, Interposing, Supervision and Special Purpose Relays. Answers for energy Siemens Protection Devices Limited 2 7PG17 XR101 & XR102 Intertripping Relay
More information