German Technology Research Program IT2Green
|
|
- Marvin Cooper
- 7 years ago
- Views:
Transcription
1 German Technology Research Program IT2Green Dr. Nils F. Nissen (IT2Green Scientific Support Team) Fraunhofer Institute for Reliability and Microintegration (IZM), Head of Department Environmental and Reliability Engineering
2 IT2Green Overview IT2Green energy efficient ICT for economy, administration and habitation Time span M sponsorship by the Federal Ministry for Economic Affairs and Energy Participants: companies, research institutes, universities and public authorities 10 research projects + accompanying scientific support team 2
3 3 Thematic clusters with 10 joint research projects Intellispektrum GreenIT Cockpit GGC Lab Desi Pinta Migrate! GreenPAD ComGreen AdaptiveSense AC4DC 3
4 Green-IT improvement options Optimizing power consumption in telecommunication networks through: Load adaptive power management of network elements (e.g. utilization of macro cells in combination with small cells in radio access networks) Power down of IT resources during night hours (e.g. power down of network elements such as routers in transport networks) Utilization of existing energy storage capacity during peak hours (e.g. back-up batteries in larger telecommunication sites) Optimizing power consumption in data centers & cloud applications: Improved IT resource utilization based on condition monitoring and load prognosis (e.g. load shifting and tasks scheduling in data centers) Holistic control of data center infrastructure and IT resources (e.g. improvement of thermal management) Utilization of renewable energy sources and live migration of IT services between different data centers 4
5 Project AC4DC: Adaptive Computing for Green Data Centers Exemplary Research and Development Topics: Novel container data center concept Optimization of IT utilization beyond virtualization Live migration of services between different data centers 5
6 Development of a novel Container Data Center Specs of test data center (container) 20 kw Uninterruptable Power Supply (UPS) 20 kw Cooling with Liquid Cooling Package (LCP) RiZone Monitoring Software Specs of block heat and power plant 2 redundant engines 2 x 8 kw electrical energy 2 x 17 kw thermal energy 9 kw adsorption cooling power (Invensor LTC 09) Picture source: Rittal 6
7 Optimization of IT utilization in data centers Measure #2: Dynamic load and power management for continuous services Measure #3: Scheduler for sporadic tasks (decision making based on various data) Cooling & Power Infrastructure Service 3 Service 2 Shared Server Pool Batch Server Pool Measure #1: Load adaptive control of climate and power supply infrastructure Service 1 Task 1 Service 4 Service m Task 4 Task k 1 Server 1 Task 2 Task 3 Task 5 Server 2 Server n Server 1 Server 2 Activation / Deactivation / Selection of Servers Task k Server l 7
8 Live migration of services between data centers Objective: Utilizing locally available renewable energy resources or free IT resources Migration of services based on weather and load prognosis as well as an automated local condition analysis Picture source: Rittal 8
9 Results and improvement potential Load and power management based on condition monitoring and load prognostic reduces the resulting power consumption of servers up to 25% Small Data Center (~150 server units): 150 MWh/a ( /year) Large Data Center (~7.000 server units): 1 GWh/a (1 Mio /year) In comparison: With an average virtualization rate an energy saving of only about 6% to 11% is realistic. In addition to energy savings, load adaptive IT utilization will significantly decrease hardware and help consolidation Novel cooling concept (block heat and power plant) as well as the all subsections addressing climate control created an energy saving of 17% The reduction in cooling overhead improved the Power Usage Effectiveness (PUE) to an excellent Factor 1,1. Live migration between data centers has the potential of increased resource utilization. A reduction in power consumption of up to 20% has been calculated.
10 Thank you for your attention! Fraunhofer Institute for Reliability and Microintegration IZM Director Prof. Klaus-Dieter Lang Your contact: Dr. Nils F. Nissen Special thanks to all IT2Green partners and to Fraunhofer IZM
Research results of the AC4DC project. www.bmwi.de
Research results of the AC4DC project www.bmwi.de Project summary Project title: BMWi code: AC4DC - Adaptive Computing for Green Data Centers 01 ME11046A Term: 01/05/2011 to 30/10/2014 Consortium: Rittal
More informationThursday, April 26, 2012 Sydney New South Wales TECHNICAL ARTICLE FOR IMMEDIATE RELEASE
RITTAL Pty Ltd 130-140 Parraweena Road Miranda NSW 2228 ABN 79 000 439 976 Thursday, April 26, 2012 Sydney New South Wales TECHNICAL ARTICLE FOR IMMEDIATE RELEASE RITTAL Pty Ltd HEAD OFFICE 130-140 Parraweena
More informationSiemens SAP Cloud - Infrastructure as a Service
Siemens SAP Cloud - Infrastructure as a Service Siemens Value Proposition April 2010 Agenda 1 Challenges with traditional infrastructure setup 2 Siemens SAP Cloud solution 3 Benefits of Siemens SAP Cloud
More informationData Center Smart Grid Integration Considering Renewable Energies and Waste Heat Usage. Of Data Centers, Smart Grids and a Greener Future
Data Center Smart Grid Integration Considering Renewable Energies and Waste Heat Usage Of Data Centers, Smart Grids and a Greener Future Dipl.-Inform. Stefan Janacek Dr. Gunnar Schomaker
More informationENERGY EFFICIENT DATA CENTRES AND STORAGE. Peter James University of Bradford
ENERGY EFFICIENT DATA CENTRES AND STORAGE Peter James University of Bradford ABOUT US 1998 Co-founded world s first NGO on GreenIT EU Expert Advisors/Project Managers on ICT & Energy Efficiency; Environmental
More informationHow To Use Rittal'S Rizone
RiZone Data Centre Infrastructure Management Enclosures Power Distribution Climate Control IT INFRASTRUcTURe SOFTWARE & SERVICEs RiZone Data Centre Infrastructure Management What can the RiZone Data Centre
More informationServer room guide helps energy managers reduce server consumption
Server room guide helps energy managers reduce server consumption Jan Viegand Viegand Maagøe Nr. Farimagsgade 37 1364 Copenhagen K Denmark jv@viegandmaagoe.dk Keywords servers, guidelines, server rooms,
More informationICT and the Green Data Centre
ICT and the Green Data Centre Scott McConnell Sales Manager c/o Tanya Duncan MD Interxion Ireland Green Data Centres Our Responsibility Data centre greenhouse gas emissions are projected to quadruple by
More informationSolve your IT energy crisis WITH An energy SMArT SoluTIon FroM Dell
Solve your IT energy crisis WITH AN ENERGY SMART SOLUTION FROM DELL overcome DATA center energy challenges IT managers share a common and pressing problem: how to reduce energy consumption and cost without
More informationFEDERAL UTILITY PARTNERSHIP WORKING GROUP SEMINAR April 22-23, 2015 Nashville, TN
FEDERAL UTILITY PARTNERSHIP WORKING GROUP SEMINAR April 22-23, 2015 Nashville, TN Data Centers New Market For Performance Contracting Jake Wooley IT Program Manager, OCIO Agenda Situational Awareness Opportunities
More informationOverview of Green Energy Strategies and Techniques for Modern Data Centers
Overview of Green Energy Strategies and Techniques for Modern Data Centers Introduction Data centers ensure the operation of critical business IT equipment including servers, networking and storage devices.
More informationSmart Sustainable City of Nuremberg Energy strategy and ongoing activities Dr. Peter Pluschke, Deputy Mayor for Environment and Health
Smart Sustainable City of Nuremberg Energy strategy and ongoing activities Dr. Peter Pluschke, Deputy Mayor for Environment and Health Slide 1 What is the motivation for the city council to sign the Green
More informationData Centers: Definitions, Concepts and Concerns
Data Centers: Definitions, Concepts and Concerns Arash Mousavi DCC September 2013 Agenda 1. Introduction 2. Issues in Modern Data Centers: Siemens Integrated Data Center Solutions 3. Issues in Modern Data
More informationGHG Protocol Product Life Cycle Accounting and Reporting Standard ICT Sector Guidance. Chapter 8: 8 Guide for assessing GHG emissions of Data Centers
GHG Protocol Product Life Cycle Accounting and Reporting Standard ICT Sector Guidance Chapter : Guide for assessing GHG emissions of Data Centers DRAFT March 0 Table of Contents GHG Protocol ICT Sector
More informationHow green is your data center?
Siemens Answers: Sustainable Future How green is your data center? Istanbul June 01, 2010 Agenda 1 Solution 2 Siemens Data Center Approach 2 Designing with multiple power density zones can reduce energy
More informationData Center Facility Basics
Data Center Facility Basics Ofer Lior, Spring 2015 Challenges in Modern Data Centers Management, Spring 2015 1 Information provided in these slides is for educational purposes only Challenges in Modern
More informationSmart Campus Management with Cloud Services
UNIVERSITY TRANSILVANIA OF BRAŞOV FACULTY OF ELECTRICAL ENGINEERING AND COMPUTER SCIENCE DEPARTMENT OF AUTOMATION, ELECTRONICS AND COMPUTER SCIENCE Sorin-Aurel Moraru, prof.dr.eng. Department Director
More informationWhite Paper RiZone The Rittal Management Software for IT infrastructures
White Paper RiZone The Rittal Management Software for IT infrastructures Bernd Hanstein Klaus Hendlmeier Thorsten Weller Copyright 2009 All rights reserved. Rittal GmbH & Co. KG Auf dem Stützelberg 35745
More informationGreen Computing. What is Green Computing?
Green Computing David Irwin Dept of Computer Science UMass Amherst What is Green Computing? Greening of computing Sustainable IT How to design energy-efficient hardware, software and systems? Computing
More informationData Center Energy Use, Metrics and Rating Systems
Data Center Energy Use, Metrics and Rating Systems Steve Greenberg Energy Management Engineer Environmental Energy Technologies Division Lawrence Berkeley National Laboratory October 31, 2007 Today s s
More informationResearch results of the GGC-LAB project. www.bmwi.de
Research results of the GGC-LAB project www.bmwi.de Project summary Project title: GGC-LAB - Government Green Cloud Laboratory BMWi code: 01 ME 11035A Term: 01/06/2011 to 30/11/2014 Consortium: regio it
More informationSpecialty Environment Design Mission Critical Facilities
Brian M. Medina PE Associate Brett M. Griffin PE, LEED AP Vice President Environmental Systems Design, Inc. Mission Critical Facilities Specialty Environment Design Mission Critical Facilities March 25,
More informationRiMatrix S Make easy.
RiMatrix S Make easy. 2 RiMatrix S Rittal The System. The whole is more than the sum of its parts. The same is true of Rittal The System. With this in mind, we have bundled our innovative enclosure, power
More informationGuideline for Water and Energy Considerations During Federal Data Center Consolidations
Guideline for Water and Energy Considerations During Federal Data Center Consolidations Prepared for the U.S. Department of Energy Federal Energy Management Program By Lawrence Berkeley National Laboratory
More informationLeveraging Renewable Energy in Data Centers: Present and Future
Leveraging Renewable Energy in Data Centers: Present and Future Ricardo Bianchini Department of Computer Science Collaborators: Josep L. Berral, Inigo Goiri, Jordi Guitart, Md. Haque, William Katsak, Kien
More informationPower Management of Cell Sites
International Refereed Journal of Engineering and Science (IRJES) ISSN (Online) 2319-183X, (Print) 2319-1821 Volume 2, Issue 9 (September 2013), PP.41-45 Power Management of Cell Sites K.Santhosh Kumar
More informationEnergy Efficiency and Green Data Centers. Overview of Recommendations ITU-T L.1300 and ITU-T L.1310
Energy Efficiency and Green Data Centers Overview of Recommendations ITU-T L.1300 and ITU-T L.1310 Paolo Gemma Chairman of Working Party 3 of ITU-T Study Group 5 International Telecommunication Union Agenda
More informationEuropean Business Reliance Centres when Commodity serves Green IT
European Business Reliance Centres when Commodity serves Green IT www.ebrc.com www.trusteddatacentre.com www.trustedcloudeurope.com www.trustedmanagedservices.com ebrc COMPANY PROFILE 5 datacenters = 17.000
More informationGreen Computing Tutorial Prashant Shenoy, David Irwin
Green Computing Tutorial Prashant Shenoy, David Irwin Dept of Computer Science UMass Amherst What is Green Computing? Greening of computing Sustainable IT How to design energy-efficient hardware, software
More informationData Centers That Deliver Better Results. Bring Your Building Together
Data Centers That Deliver Better Results Bring Your Building Together 1 Meeting the high demands of your data center Meeting the increasing heat loads associated with growing computational needs requires
More informationDATA CENTRE DESIGN AND
SPUSC 2008 SOUTH PACIFIC USER SERVICES CONFERENCE DATA CENTRE DESIGN AND ENERGY INITIATIVES Presented by Jarrad Clift Electrical Engineer Greenstar Accredited Presentation Content Data Centres General
More informationData Center Analysis and Design Analysis of SU s Green Data Center Performance
Data Center Analysis and Design Analysis of SU s Green Data Center Performance Dustin W. Demetriou, PhD Development Engineer Advanced Thermal Energy Efficiency Lab IBM D. W. Demetriou October 29, 2013-1
More informationFNT EXPERT PAPER. // Data Center Efficiency AUTHOR. Energy management tools and methods for green IT compliance. www.fntsoftware.
FNT EXPERT PAPER AUTHOR Soeren Juul Schroeder Vice President, UK/Ireland & Nordics/Baltics FNT GmbH // Data Center Efficiency Energy management tools and methods for green IT compliance Environmental sustainability
More informationData Centre Capacity and Electricity Use How the EU Code of Conduct can help your data centre electricity bill
Data Centre Capacity and Electricity Use How the EU Code of Conduct can help your data centre electricity bill Chris Cartledge Independent Consultant C.Cartledge@sheffield.ac.uk Summary ICT Electricity
More informationThe Mission Critical Data Center Understand Complexity Improve Performance
The Mission Critical Data Center Understand Complexity Improve Performance Communications Technology Forum Fall 2013 Department / Presenter / Date 1 Rittal IT Solutions The State of the Data Center Market
More informationDataCenter 2020: first results for energy-optimization at existing data centers
DataCenter : first results for energy-optimization at existing data centers July Powered by WHITE PAPER: DataCenter DataCenter : first results for energy-optimization at existing data centers Introduction
More informationIntroduction to Virtualization. Paul A. Strassmann George Mason University October 29, 2008, 7:20 to 10:00 PM
Introduction to Virtualization Paul A. Strassmann George Mason University October 29, 2008, 7:20 to 10:00 PM 1 Data Center Transformation 2 Scope of Virtualization Services 3 Virtualization Evolution 4
More informationEuropean Code of Conduct for Data Centre. Presentation of the Awards 2013
European Code of Conduct for Data Centre Presentation of the Awards 2013 Paolo Bertoldi European Commission DG JRC Institute for Energy and Transport 1 The Code of Conduct for Data Centre Results Started
More informationFEAR Model - Review Cell Module Block
F.E.A.R. Returns: 5 Steps Toward Data Center Efficiency Today Objectives Benefits for ITS professionals Brief review of the FEAR data center Define data center efficiency Link efficiency to the FEAR data
More informationGlobal Green Data Center Best Practices In Action
Global Green Data Center Best Practices In Action DOUG WASHBURN VICE PRESIDENT & RESEARCH DIRECTOR September 25, 2013 Four questions I will answer 1 Why is green important to your business? 2 Why is green
More informationDataCenter 2020. Data Center Management and Efficiency at Its Best. OpenFlow/SDN in Data Centers for Energy Conservation.
DataCenter 2020. Data Center Management and Efficiency at Its Best. OpenFlow/SDN in Data Centers for Energy Conservation. Dr. Rainer Weidmann, DC Architecture & DC Innovation Dr. Rainer Weidmann, DC Architecture
More informationSupply and Demand Management in the Scharnhauser Park-Project, Germany
Supply and Demand Management in the Scharnhauser Park-Project, Germany Dietrich Schneider Page 1 Dietrich Schneider Working at the University of Stuttgart since ten years, as a scientist in the field of
More informationEnabling an agile Data Centre in a (Fr)agile market
Enabling an agile Data Centre in a (Fr)agile market Phil Dodsworth Director, Data Centre Solutions 2008 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without
More informationHow to build your Data Center Digitice roadshow Vaasa 3.12.2015
How to build your Data Center Digitice roadshow Vaasa 3.12.2015 Mikko Aho Sales Director 044 593 4698 1 A Strong Family The Friedhelm Loh Group a successful business 11.500 employees worldwide 78 int.
More informationA PRACTICAL GUIDE TO COST SAVINGS WITH VIRTUALIZATION
15770 Dallas Parkway, Suite 1100, LB 28 Dallas, Texas 75248 tel 214.739.5454 fax 214.739.5455 www.fusionlabs.net A WHITE PAPER TITLED: A PRACTICAL GUIDE TO COST SAVINGS WITH VIRTUALIZATION TABLE OF CONTENTS
More informationConsulting Engineering Outsourcing
Consulting Engineering Outsourcing Opportunities, challenges and strategies 5.º Fórum Lusófono das Comunicações Maputo, 24 de Abril de 2014 Maksen 2014 Consulting Engineering Outsourcing AGENDA 01. Data
More informationDatacenter Efficiency
EXECUTIVE STRATEGY BRIEF Operating highly-efficient datacenters is imperative as more consumers and companies move to a cloud computing environment. With high energy costs and pressure to reduce carbon
More informationMetrics for Data Centre Efficiency
Technology Paper 004 Metrics for Data Centre Efficiency Workspace Technology Limited Technology House, PO BOX 11578, Sutton Coldfield West Midlands B72 1ZB Telephone: 0121 354 4894 Facsimile: 0121 354
More informationDC4Cities: Incresing Renewable Energy Utilization of Data Centre in a smart cities. Page 1
DC4Cities: Incresing Renewable Energy Utilization of Data Centre in a smart cities M A RTA CHINNICI R E S E A R C H E R E N E A Page 1 DC4Cities Origins Green Service Level Agreements To Adapt the Renewable
More informationRittal Liquid Cooling Series
Rittal Liquid Cooling Series by Herb Villa White Paper 04 Copyright 2006 All rights reserved. Rittal GmbH & Co. KG Auf dem Stützelberg D-35745 Herborn Phone +49(0)2772 / 505-0 Fax +49(0)2772/505-2319 www.rittal.de
More informationSPARC Enterprise s Approach to Virtualization and Its Contribution to ICT Society
SPARC Enterprise s Approach to Virtualization and Its Contribution to ICT Society Masaru Nukada Akio Satori In recent years, it has become common practice to implement virtualization technology across
More informationData Center Optimization and Consolidation. Global Infrastructure Services
Data Center Optimization and Consolidation Global Infrastructure Services cgi.com 2 CGI s consulting team helps clients develop and execute solutions that are responsive to their unique business needs
More informationEcodesign Directive: An Overview of the Preparatory Study on Enterprise Servers and Storage
Ecodesign Directive: An Overview of the Preparatory Study on Enterprise Servers and Storage D. Polverini, European Commission Thibault Faniger, BIO Intelligence Service Ecodesign Preparatory Study DG ENTR
More informationBytes and BTUs: Holistic Approaches to Data Center Energy Efficiency. Steve Hammond NREL
Bytes and BTUs: Holistic Approaches to Data Center Energy Efficiency NREL 1 National Renewable Energy Laboratory Presentation Road Map A Holistic Approach to Efficiency: Power, Packaging, Cooling, Integration
More informationINTEGRATION OF DISTRIBUTED GENERATION AT THE REGIONAL ENERGY MARKET ETELLIGENCE
INTEGRATION OF DISTRIBUTED GENERATION AT THE REGIONAL ENERGY MARKET ETELLIGENCE Die Integration verteilter Erzeuger am regionalen Energiemarktplatz etelligence Dr. Christof Wittwer Fraunhofer Institute
More informationU.S. Department of Energy, National Renewable Energy Laboratory, IT Sustainability Case Study
SUMMARY The U.S. Department of Energy s (DOE) National Renewable Energy Laboratory (NREL) designed the Research Support Facility (RSF) to demonstrate that a large office building could lead the way in
More informationCase Study: Guaranteed efficiency through standardised data centres
Case Study: Guaranteed efficiency through standardised data centres Rittal / SEC Event / October 2014 1 Case Study: Guaranteed efficiency through standardised data centres Smart Energy Community Event
More informationData centers & energy: Did we get it backwards? Adam Wierman, Caltech
Data centers & energy: Did we get it backwards? Adam Wierman, Caltech The typical story about energy & data centers: The typical story about energy & data centers: Sustainable data centers Remember: The
More informationPresented at ISA Summit - Stockholm, Sweden. March 19, 2009 Dean Nelson Sr. Director, Global Lab & Datacenter Design Services (GDS)
Presented at ISA Summit - Stockholm, Sweden March 19, 2009 Dean Nelson Sr. Director, Global Lab & Datacenter Design Services (GDS) 1 Unique Challenge 2 Demand and Capacity Are Colliding......And Data Centers
More informationSmart Energy Consumption and the Smart Grid
Smart Energy Consumption and the Smart Grid Executive Summary The nation s outdated electrical infrastructure is being transformed. Fundamental changes that add intelligence, integrated communications
More informationGreening The Data Center
Greening The Data Center A Five Step Method for CIO s and Data Center Managers Professionals who manage Data Centers know what is expected from them for performance and uptime. What many are only just
More informationGreen IT Solutions From Desktop to Datacenter. Dave Spear Sr. Engagement Manager & Sustainability Advocate dave.spear@microsoft.
Green IT Solutions From Desktop to Datacenter Dave Spear Sr. Engagement Manager & Sustainability Advocate dave.spear@microsoft.com Agenda Our Commitment Today s Environment PC, Server, Storage Computerworld
More informationThe Energy Transition in Germany Past, Present and Future
The Energy Transition in Germany Past, Present and Future smart energy Paraná, Conferência International 2014 9 May 2014 Dr. Carsten Tschamber A Brief History of the Energiewende 1973 - oil crisis, Federal
More informationCarbonDecisions. The green data centre. Why becoming a green data centre makes good business sense
CarbonDecisions The green data centre Why becoming a green data centre makes good business sense Contents What is a green data centre? Why being a green data centre makes good business sense 5 steps to
More informationBCA-IDA Green Mark for Existing Data Centres Version EDC/1.0
BCA-IDA Green Mark for Existing Data Centres Version EDC/1.0 To achieve GREEN MARK Award Pre-requisite Requirement All relevant pre-requisite requirements for the specific Green Mark Rating are to be complied
More informationJonathan Mitchell CDS Research Project April 18, 2012
Jonathan Mitchell CDS Research Project April 18, 2012 Problem/Background What is Green IT? Energy Efficient IT Advanced Power and Cooling Integration with Building and Landscape Architecture Using IT to
More informationIntegrating the customer experience through unifying software - The Microsoft Vision
VAASAETT - RESPOND 2010 Integrating the customer experience through unifying software - The Microsoft Vision Principal Author Andreas Berthold- van der Molen, Microsoft EMEA Contents The New Energy Ecosystem
More informationIBM and Dynamic Infrastructure. Doug Neilson, IBM Systems Group May 2009
IBM and Dynamic Infrastructure Doug Neilson, IBM Systems Group May 2009 IBM s Smarter Planet Strategy Every human being, company, organization, city, nation, natural system and man-made system is becoming
More informationFederal Data Center Consolidation Initiative (FDCCI) FAQs May 2012
Federal Data Center Consolidation Initiative (FDCCI) FAQs May 2012 1. What is the Federal Data Center Consolidation Initiative (FDCCI)? The Federal CIO Vivek Kundra established the FDCCI in a memo dated
More informationRecommendations for Measuring and Reporting Overall Data Center Efficiency
Recommendations for Measuring and Reporting Overall Data Center Efficiency Version 1 Measuring PUE at Dedicated Data Centers 15 July 2010 Table of Contents 1 Introduction... 1 1.1 Purpose Recommendations
More informationSmart Cities. Integrated approach for innovative technologies. 2nd Annual Conference of the ETP on. Budapest, 6th May 2011
Smart Cities Integrated approach for innovative technologies 2nd Annual Conference of the ETP on Renewable Heating and Cooling Budapest, 6th May 2011 Brigitte Bach, AIT Energy Department Low Carbon Economy
More informationGreen IT Workplace! ICT4S 2013! Green IT Crash Course!
Green IT Workplace! ICT4S 2013! Green IT Crash Course! Agenda! 2! Motivation! Workplace devices! Real world example: Thin clients vs. desktop computers! Peripheral equipment! Real world example: Efficient
More information1.4 PUE The New Mandate for Federal Data Center Energy Efficiency. Strategic Sustainability Performance Plan (SSPP)
1.4 PUE The New Mandate for Federal Data Center Energy Efficiency Strategic Sustainability Performance Plan (SSPP) Outline What are the Requirements? What are the Challenges? Resources & Tools Summary
More informationHarmonizing Global Metrics for Data Center Energy Efficiency
Harmonizing Global Metrics for Data Center Energy Efficiency Dan Azevedo, Symantec Chairman - Metrics & Measurements Work Group Industry Trends Energy Efficient IT The Climate Group: Smarter technology
More informationEnergy Savings in the Data Center Starts with Power Monitoring
Energy Savings in the Data Center Starts with Power Monitoring As global competition intensifies, companies are increasingly turning to technology to help turn mountains of data into a competitive edge.
More information1. Simulation of load balancing in a cloud computing environment using OMNET
Cloud Computing Cloud computing is a rapidly growing technology that allows users to share computer resources according to their need. It is expected that cloud computing will generate close to 13.8 million
More informationReducing Data Center Loads for a Large-Scale, Net Zero Office Building
rsed Energy Efficiency & Renewable Energy FEDERAL ENERGY MANAGEMENT PROGRAM Reducing Data Center Loads for a Large-Scale, Net Zero Office Building Energy Efficiency & Renewable Energy Executive summary
More informationInternational Telecommunication Union SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF TELECOMMUNICATION CABLES IN PUBLIC NETWORKS
International Telecommunication Union ITU-T TELECOMMUNICATION STANDARDIZATION SECTOR OF ITU Technical Paper (13 December 2013) SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF TELECOMMUNICATION CABLES
More informationSelf-organization of applications and systems to optimize resources usage in virtualized data centers
Ecole des Mines de Nantes Self-organization of applications and systems to optimize resources usage in virtualized data centers Teratec 06/28 2012 Jean- Marc Menaud Ascola team EMNantes-INRIA, LINA Motivations
More informationTulevaisuuden datakeskukset Ympäristö- ja energianäkökulmia
Tulevaisuuden datakeskukset Ympäristö- ja energianäkökulmia A single-minded approach to data center operations can be detrimental to the life and profitability of the data center. - Dr. Jonathan Koomey
More informationWhy you should opt for an external data centre: 10 no-brainers LCL WHITE PAPER. LCL, your partner in data center outsourcing 1
Why you should opt for an external data centre: 10 no-brainers LCL WHITE PAPER LCL, your partner in data center outsourcing 1 A data centre, even a small one, is a huge investment for any organisation.
More informationData centre energy efficiency metrics. Existing and proposed metrics to provide effective understanding and reporting of data centre energy
Existing and proposed metrics to provide effective understanding and reporting of data centre energy Liam Newcombe Data Centre Specialist Group 1 Introduction... 2 2 Summary... 6 3 Overview of metrics...
More informationSoSe 2014 Dozenten: Prof. Dr. Thomas Ludwig, Dr. Manuel Dolz Vorgetragen von Hakob Aridzanjan 03.06.2014
Total Cost of Ownership in High Performance Computing HPC datacenter energy efficient techniques: job scheduling, best programming practices, energy-saving hardware/software mechanisms SoSe 2014 Dozenten:
More informationNewsletter 4/2013 Oktober 2013. www.soug.ch
SWISS ORACLE US ER GRO UP www.soug.ch Newsletter 4/2013 Oktober 2013 Oracle 12c Consolidation Planer Data Redaction & Transparent Sensitive Data Protection Oracle Forms Migration Oracle 12c IDENTITY table
More informationITU-T Broadband forums
ITU-T Broadband forums Energy Efficiency and Future Data Centres Amsterdam, October 22 nd Guillaume GERARD, Senior DataCenter Expert, Orange Orange group: the DataCenter big picture No less than 78 DataCenters
More informationData Center Infrastructure Management. Experience the inner calm that comes with successful data center management. www.fntsoftware.
Data Center Infrastructure Management Experience the inner calm that comes with successful data center management. www.fntsoftware.com There was 5 exabytes of information created between the dawn of civilization
More informationDriving the Green Data Center Strategy in Established Environments
Driving the Green Data Center Strategy in Established Environments November 2008 Agenda Green IT defined Arrow Green Initiatives Data Center Other Initiatives Green Challenges Green IT Optimal use of information
More informationDefinition of effective metrics for evaluating the efficiency of hybrid power systems at telecom cell sites
Power topic #NAPT-5516-EN Technical information from Cummins Power Generation Definition of effective metrics for evaluating the efficiency of hybrid power systems at telecom cell sites A system-level
More informationInformation Technology White Paper
Information Technology White Paper Virtualization Building an Adaptive, Cost Effective Infrastructure at SSCT October 5, 2009 As the College grows the College needs to be poised to respond faster to market
More informationGreen IT Promotion Council, Japan
Concept of New Metrics for Data Center Energy Efficiency Introduction of Datacenter Performance per Energy [ DPPE ] Green IT Promotion Council, Japan February2010 Abstract Power Usage Effectiveness (PUE)
More informationThe Effect of Data Centre Environment on IT Reliability & Energy Consumption
The Effect of Data Centre Environment on IT Reliability & Energy Consumption Steve Strutt EMEA Technical Work Group Member IBM The Green Grid EMEA Technical Forum 2011 Agenda History of IT environmental
More informationStandardised Data centres. Sales presentation
Standardised Data centres 1 Standardised Data Centres l Motivation ll Change of paradigm lll Rittal s Data centre concept lv Benefits V Summary Standardised Data Centre Motivation Does every data centre
More informationHow To Virtualize A Server At Swic
Implementing Server Virtualization At Southwestern Illinois College (Case Study) Submitted by Christine Leja, CDP/CCP Background Southwestern Illinois College (SWIC) is a community college started in 1946
More informationGreen Data Centre Design
Green Data Centre Design A Holistic Approach Stantec Consulting Ltd. Aleks Milojkovic, P.Eng., RCDD, LEED AP Tommy Chiu, EIT, RCDD, LEED AP STANDARDS ENERGY EQUIPMENT MATERIALS EXAMPLES CONCLUSION STANDARDS
More informationCoolEmAll - Tools for realising an energy efficient data centre
CoolEmAll - Tools for realising an energy efficient data centre Wolfgang Christmann christmann informationstechnik + medien GmbH & Co. KG www.christmann.info 1 Outline CoolEmAll project RECS system towards
More informationAIA Provider: Colorado Green Building Guild Provider Number: 50111120. Speaker: Geoff Overland
AIA Provider: Colorado Green Building Guild Provider Number: 50111120 Office Efficiency: Get Plugged In AIA Course Number: EW10.15.14 Speaker: Geoff Overland Credit(s) earned on completion of this course
More informationEMC DURHAM CLOUD DATA CENTER
EMC DURHAM CLOUD DATA CENTER Energy efficient design and construction EMC IT was hard at work reducing operational costs, increasing IT agility, and preparing for a dynamic future in the cloud when it
More informationSo you want to build a data centre? Look what s coming from BICSI! Matt Flowerday Capitoline FZC mflowerday@capitoline.org
So you want to build a data centre? Look what s coming from BICSI! Matt Flowerday Capitoline FZC mflowerday@capitoline.org So you want to build a data centre? Who do you contact? How do you work out what
More informationFrom energy audits to ICT implementation: a methodology applied to sport facilities
WORKSHOP Challenges, Opportunities, and Lessons Learned from ongoing Research Projects From energy audits to ICT implementation: a methodology applied to sport facilities Enrico Sabbatini UNIVERSITA POLITECNICA
More informationPrivate Cloud. One solution managed by Applied
Private Cloud : : C L O U D S E R V I C E S : : One solution managed by Applied THE CLOUD IS NO LONGER AN IT CONSIDERATION ALONE IT IS FUNDAMENTALLY CHANGING THE WAY EXECUTIVES ACROSS DEPARTMENTS VIEW
More information