Green Computing Tutorial Prashant Shenoy, David Irwin
|
|
|
- Maude Harris
- 10 years ago
- Views:
Transcription
1 Green Computing Tutorial Prashant Shenoy, David Irwin Dept of Computer Science UMass Amherst
2 What is Green Computing? Greening of computing Sustainable IT How to design energy-efficient hardware, software and systems? Computing for Greening Use of IT to make physical infrastructure efficient? Homes, offices, buildings, transportation
3 Outline Greening of IT Data centers Desktops IT for Greening Building and home monitoring Renewable energy for homes
4 Some History Energy-efficient mobile devices a long standing problem Motivation: better battery life, not green Recent growth of data centers More energy-efficient server design Motivation: lower electricity bills Green systems, lower carbon footprint
5 Computing and Power Consumption Energy to Compute 20% power usage in office buildings 50%-80% at a large college 3% of our carbon footprint and growing Data centers are a large fraction of the IT carbon footprint PCs, mobile devices also a significant part
6 What is a data center? Facility for housing a large number of servers and data storage Google data center (Dalles, OR) 12 football fields in size Compare to box stores! 100 MW of power Enough for a small city ~ 100K servers Source: Dan Reed presentation at NSF Science of Power Management Workshop, Arlington VA, 2009
7 Data Center Energy Costs Source: Dan Reed presentation at NSF Science of Power Management Workshop, Arlington VA, 2009
8 Energy Bill of a Google Data center Assume 100,000 servers Monthly cost of 1 server 500W server Cost=(Watts X Hours / 1000) * cost per KWH Always-on server monthly cost = $50 Monthly bill for 100K servers = $5M What about cost of cooling? Use PUE (power usage efficiency) PUE =2 => cost doubles Google PUE of 1.2 => 20% extra on 5M (~ $6M)
9 Class exercises Calculate the energy cost and carbon footprint of A laptop A desktop Always-on machine A machine that is switched off in the night
10 How to design green data centers? A green data center will Reduce the cost of running servers Cut cooling costs Use green design and green energy
11 Reducing server energy cost Buy / design energy-efficient servers Better hardware, better power supplies DC is more energy-efficient than AC Manage your servers better! Intelligent power management Turn off servers when not in use Virtualization => can move apps around
12 Reducing cooling costs Better air conditioning Thermal engineering / better airflow Move work to cooler regions Newer cooling Naturally cooled data ctrs Underground bunkers Reference: Dan Reed presentation at NSF Science of Power Management Workshop, Arlington VA, 2009
13 Build them in Iceland
14 Desktop Power management Large companies => 50K desktops or more Always on: no one switches them off at night Night IT tasks: backups, patches etc Better desktop power management Automatic sleep policies Automatic / easy wakeups [see Usenix 2010]
15 Outline Greening of IT Data centers Desktops IT for Greening Building and home monitoring Renewable energy for homes
16 IT for Greening How can we use IT to make buildings green? Use sensors, smart software, smart appliances, smart meters..
17 Potential Solution Monitor and profile usage Power supply/demand profile Increase Efficiency Turn on/off systems automatically Consolidate computers Tune various subsystems Use Alternative Energy Sources Tune systems to variable energy supplies
18 Potential Solution Monitor and profile usage Power supply/demand profile Increase Efficiency Turn on/off systems automatically Consolidate computers Tune various subsystems Use Alternative Energy Sources Tune systems to variable energy supplies
19 Fine-grained Building Monitoring Designed sensors for power outlet monitoring Based on the Kill-A-Watt design Modified sensor with low-power wireless radio Transmits data to strategically placed receivers Use plug computers for receivers
20 Fine-grained Building Monitoring Advantages Accurate, fine-grain data Cheap money-wise to build Able to put them everywhere Good experience for undergraduates Disadvantage Expensive time-wise to build
21 Tweet-a-watt Project Or just google for tweetawatt
22 Umass Green computing sensors to monitor PC, printers, kitchen Web application for viewing or querying data
23 Meter-level Monitoring Many off-the-shelf products available TED The Energy Detective Blue Line PowerCost Monitor
24 TED Meter Monitoring Install on main panel
25 View on Google Powermeter
26 Blue Line Powercost Monitor Install on electricity meter (no wiring) Easier to install but not Internet-enabled
27 Energy Harvesting Deployment Collect data on wind and solar energy harvesting How can we use solar panels and wind turbines in Western Mass. to power IT? Is the harvesting predictable? Study the best way to use energy to power compute clusters Utility-scale energy-harvesting data centers are already coming online We are looking at smaller scale
28 Energy Harvesting Deployment Deployed multiple 400 watt wind turbines and 65 watt solar panels Use Hobo Data Logger to automatically upload data for archiving and viewing
29 Deployments in Western MA
30 Energy Harvesting in Winter Winters are very challenging for solar deployments in New England
31 Energy Harvesting Deployment
32 Analyzing Forecast Data Harvesting is highly variable Both wind and solar in Amherst, MA are variable NWS data reveals high variability in other regions too
33 Analyzing Forecast Data Forecasts are better for prediction than the Past
34 Summary Greening of computing Design of energy-efficient hardware & software Computing for greening Use of IT for monitoring Use of intelligent software for power management Forecasting for renewable energy harvesting
Green Computing. What is Green Computing?
Green Computing David Irwin Dept of Computer Science UMass Amherst What is Green Computing? Greening of computing Sustainable IT How to design energy-efficient hardware, software and systems? Computing
Today: Data Centers & Cloud Computing" Data Centers"
Today: Data Centers & Cloud Computing" Data Centers Cloud Computing Lecture 25, page 1 Data Centers" Large server and storage farms Used by enterprises to run server applications Used by Internet companies
Leveraging Renewable Energy in Data Centers: Present and Future
Leveraging Renewable Energy in Data Centers: Present and Future Ricardo Bianchini Department of Computer Science Collaborators: Josep L. Berral, Inigo Goiri, Jordi Guitart, Md. Haque, William Katsak, Kien
Green IT Solutions From Desktop to Datacenter. Dave Spear Sr. Engagement Manager & Sustainability Advocate dave.spear@microsoft.
Green IT Solutions From Desktop to Datacenter Dave Spear Sr. Engagement Manager & Sustainability Advocate [email protected] Agenda Our Commitment Today s Environment PC, Server, Storage Computerworld
Energy Savings in the Data Center Starts with Power Monitoring
Energy Savings in the Data Center Starts with Power Monitoring As global competition intensifies, companies are increasingly turning to technology to help turn mountains of data into a competitive edge.
SoSe 2014 Dozenten: Prof. Dr. Thomas Ludwig, Dr. Manuel Dolz Vorgetragen von Hakob Aridzanjan 03.06.2014
Total Cost of Ownership in High Performance Computing HPC datacenter energy efficient techniques: job scheduling, best programming practices, energy-saving hardware/software mechanisms SoSe 2014 Dozenten:
Division of Administration (DOA) Desktop Support
Division of Administration (DOA) Desktop Support Computer Power Conservation Settings for XP & Vista Operating Systems XP Power Options Overview Using Power Options in Control Panel, you can reduce the
The Design of a Wi-Fi Enabled Cloud Monitoring Device
Paper ID #7655 The Design of a Wi-Fi Enabled Cloud Monitoring Device Dr. Esther T. Ososanya, University of the District of Columbia Dr. Ososanya is a professor of Electrical and Computer Engineering at
Data Center Design and Energy Management
Agenda EasyStreet Online Services, Inc. Data Center Design and Energy Management Introduction to EasyStreet Speaker Bio EasyStreet Sustainability Data Center 1 (Retrofit completed May 2010) Data Center
Data Center Facility Basics
Data Center Facility Basics Ofer Lior, Spring 2015 Challenges in Modern Data Centers Management, Spring 2015 1 Information provided in these slides is for educational purposes only Challenges in Modern
Ringing at the Door. Boiling an egg. Moving by car. Flows of solar energy. There is no energy crisis. How to boil an egg?
Delft University of Technology There is no energy crisis How to boil an egg? Prof. Dr. Ad van Wijk 20-10-2011 Energy efficiency world wide is about 2% The sun gives us in one hour more energy than the
Remote Monitoring in Telecom: A brief Review
Remote Monitoring in Telecom: A brief Review Ziema Mushtaq Dept. of Computer Science, University of Kashmir, Srinagar [email protected] Syed Mohsin Saif Research Scholar, Dept. of CS &IT, School of
Solar Panels and the Smart Grid
Solar Panels and the Smart Grid In the Pepco Region Steve Sunderhauf Jeff Roman Joshua Cadoret David Pirtle Outline Pepco Region Background Renewable Portfolio Standards (RPS) Pepco s Blueprint for the
Overview of Green Energy Strategies and Techniques for Modern Data Centers
Overview of Green Energy Strategies and Techniques for Modern Data Centers Introduction Data centers ensure the operation of critical business IT equipment including servers, networking and storage devices.
Measuring Electricity Class Activity
Measuring Electricity Class Activity Objective: To understand what energy is, how it impacts our daily lives, and how one can become an energy steward. Learning Outcomes: Students will: 1. Understand where
Renewable Energy Monitor User Manual And Software Reference Guide. [email protected] (979) 703-1925
Renewable Energy Monitor User Manual And Software Reference Guide [email protected] (979) 703-1925 1 Introducing the Horizon Renewable Energy Monitor The Renewable Energy Monitor is an educational
Reducing operating costs of telecom base stations with remote management
Reducing operating costs of telecom base stations with remote management Whitepaper How remote management can be used to cut operating expenses of existing telecom infrastructure. HMS Industrial Networks
Measuring Power in your Data Center: The Roadmap to your PUE and Carbon Footprint
Measuring Power in your Data Center: The Roadmap to your PUE and Carbon Footprint Energy usage in the data center Electricity Transformer/ UPS Air 10% Movement 12% Cooling 25% Lighting, etc. 3% IT Equipment
An Intelligent System for Electrical Energy Management in Buildings
An Intelligent System for Electrical Energy Management in Buildings Giuseppe Anastasi Dept. of Information Engineering University of Pisa, Italy E-mail: [email protected] Francesco Corucci
AIA Provider: Colorado Green Building Guild Provider Number: 50111120. Speaker: Geoff Overland
AIA Provider: Colorado Green Building Guild Provider Number: 50111120 Office Efficiency: Get Plugged In AIA Course Number: EW10.15.14 Speaker: Geoff Overland Credit(s) earned on completion of this course
(EMR) system in resource-constrained settings. The use of the EMR at point-of-care (POC)
Centralized Power Backup System and Low-Power Computing A reliable power source is a core requirement for using an electronic medical record (EMR) system in resource-constrained settings. The use of the
Efficiency and Other Benefits of 208 Volt Over 120 Volt Input for IT Equipment
Efficiency and Other Benefits of 208 Volt Over 120 Volt Input for IT Equipment By Neil Rasmussen White Paper #27 Revision 2 Executive Summary Decisions made regarding the distribution of 208V or 120V power
Additional Solar System Information and Resources
Additional Solar System Information and Resources Background information a. Roughly 400 schools in NJ already have solar systems, producing more than 91 MW, out of approximately 2500 K- 12 schools in NJ.
Novel AMR technologies and Remote Monitoring
Novel AMR technologies and Remote Monitoring Marios Milis, SignalGeneriX Ltd [email protected] 1 AMR Overview AMR is the technology of automatically collecting consumption, diagnostic, and
Re Engineering to a "Green" Data Center, with Measurable ROI
Re Engineering to a "Green" Data Center, with Measurable ROI Alan Mamane CEO and Founder Agenda Data Center Energy Trends Benchmarking Efficiency Systematic Approach to Improve Energy Efficiency Best Practices
1. Data Centre Environment Why focus on Data Centres? Hitachi Eco-Friendly Data Centre Solutions
Hitachi Eco-Friendly Data Centre Solutions Why are efficient data centres a necessity and how can they be delivered 24 th September 2009 1 1. Data Centre Environment Why focus on Data Centres? Why are
Server Technology, Inc.
Server Technology, Inc. Power Efficiency Gains by Deploying 415 VAC Power Distribution in North American Data Centers White Paper STI-100-008 2009-April-07 Headquarters Server Technology, Inc. 1040 Sandhill
Environmental and Green Cloud Computing
International Journal of Allied Practice, Research and Review Website: www.ijaprr.com (ISSN 2350-1294) Environmental and Green Cloud Computing Aruna Singh and Dr. Sanjay Pachauri Abstract - Cloud computing
Understanding and Measuring School Electronics
Understanding and Measuring School Electronics MATERIALS NEEDED: 1. 6 energy monitoring devices (note: these can be obtained from a variety of sources, i.e., local hardware stores, internet [average cost
Energy Efficiency in New and Existing Data Centers-Where the Opportunities May Lie
Energy Efficiency in New and Existing Data Centers-Where the Opportunities May Lie Mukesh Khattar, Energy Director, Oracle National Energy Efficiency Technology Summit, Sep. 26, 2012, Portland, OR Agenda
Rules of Thumb Energy Efficiency in Buildings
Energy Efficiency in Buildings Energy Savings Cost Savings Increased Productivity Economic Development Other Standard lighting retrofits: $0.90-$1.20 per square foot. High-efficiency packaged and split
M2M & Internet of Things Opportunities
M2M & Internet of Things Opportunities The Advent of The Internet of Things Mainframe Minicomputer Desktop PC Internet Mobile Internet (1M+ Units) (10M+ Units) (100M+ Units) (1B+ Units/Users) (3B+ Users)
ECO-FRIENDLY COMPUTING: GREEN COMPUTING
ECO-FRIENDLY COMPUTING: GREEN COMPUTING Er. Navdeep Kochhar 1, Er. Arun Garg 2 1-2 Baba Farid College, Bathinda, Punjab ABSTRACT Cloud Computing provides the provision of computational resources on demand
Eco Bairros demonstration project:
Armando B. Mendes Universidade dos Açores GIFEM coordinator team demonstration project: Towards a net zero island: Distribution and demand side 2 The Origins: The demand side GIFEM Monitoring Network General
Data Centers: Definitions, Concepts and Concerns
Data Centers: Definitions, Concepts and Concerns Arash Mousavi DCC September 2013 Agenda 1. Introduction 2. Issues in Modern Data Centers: Siemens Integrated Data Center Solutions 3. Issues in Modern Data
Energy Efficiency and Green Data Centers. Overview of Recommendations ITU-T L.1300 and ITU-T L.1310
Energy Efficiency and Green Data Centers Overview of Recommendations ITU-T L.1300 and ITU-T L.1310 Paolo Gemma Chairman of Working Party 3 of ITU-T Study Group 5 International Telecommunication Union Agenda
Metrics for Data Centre Efficiency
Technology Paper 004 Metrics for Data Centre Efficiency Workspace Technology Limited Technology House, PO BOX 11578, Sutton Coldfield West Midlands B72 1ZB Telephone: 0121 354 4894 Facsimile: 0121 354
Energy Tutorial: Energy Usage. Reading meters and understanding fuel bills
Energy Tutorial: Energy Usage Reading meters and understanding fuel bills Provided by Sponsored by Gas and electricity meters are fitted in homes so as to be able to measure how much fuel the household
The Energy Harvesting Tipping Point for Wireless Sensor Applications
The Energy Harvesting Tipping Point for Wireless Sensor Applications Ever since the first watermills and windmills were used to generate electricity, energy harvesting has been an attractive source of
Solve your IT energy crisis WITH An energy SMArT SoluTIon FroM Dell
Solve your IT energy crisis WITH AN ENERGY SMART SOLUTION FROM DELL overcome DATA center energy challenges IT managers share a common and pressing problem: how to reduce energy consumption and cost without
The UCSD/Calit2 GreenLight Instrument Tom DeFanti, PI
The UCSD/Calit2 GreenLight Instrument Tom DeFanti, PI California Institute for Telecommunications and Information Technology: Calit2 Over 1000 Researchers in Two Buildings Linked via Dedicated Optical
Using the sun to generate electricity
Using the sun to generate electricity Image source: http://www.globalsolarcenter.com/files/2009/04/commercial-solar.jpg Solar panels information sheet What are the benefits? How does it work? What is the
Potpourri Track Green IT. Colin Martin Solutions Architect, Cisco Systems Inc. [email protected]
Potpourri Track Green IT Colin Martin Solutions Architect, Cisco Systems Inc. [email protected] 1 Agenda Green Drivers and Initiatives Energy Use Green Buildings and IT Green IT Datacenter Efficiency
Introduction to IT Infrastructure Components and Their Operation. Balázs Kuti
Introduction to IT Infrastructure Components and Their Operation Balázs Kuti Agenda Challenges faced by enterprises today, scale of the IT plant Diversity of an IT plant Key Server Infrastructure Components
Drilling for Dollars: IT Companies Find Energy
Drilling for Dollars: IT Companies Find Energy Jim Sinopoli, PE, LEED AP, RCDD Managing Principal, Smart Buildings LLC "Another myth is that we have all the technology we need to solve the energy problem
Public Overview of the EMerge Alliance Data/Telecom Center Standard Version 1.0
of the EMerge Alliance Data/Telecom Center Standard Version 1.0 A standard defining low voltage dc power distribution system requirements for use in data centers and telecom central offices Excerpted With
Understanding Energy Use, Taking Steps to Reduce Energy Use (Intermediate/Advanced ESOL level)
Understanding Energy Use, Taking Steps to Reduce Energy Use (Intermediate/Advanced ESOL level) Overview of Lesson This is a three-part lesson that covers: 1. energy use and common household appliances,
Harvesting Solar Energy
Harvesting Solar Energy Overview of Systems, options and benefits of Solar Energy Systems By:John Miggins Harvest Solar Energy renewable solutions to everyday needs www.harvestsolar.net 1 Solar Energy
YOUR SUNPOWER MONITORING SYSTEM GUIDE
YOUR SUNPOWER MONITORING SYSTEM GUIDE YOUR SUNPOWER MONITORING SYSTEM Congratulations on your new SunPower solar system with SunPower monitoring! SunPower s advanced monitoring solution allows you to easily
GETTING TO KNOW YOUR NEW TELSTRA MOBILE WI-FI 4G
GETTING TO KNOW YOUR NEW TELSTRA MOBILE WI-FI 4G LET S GET THIS SHOW ON THE ROAD You must be excited about your brand new Telstra Mobile Wi-Fi 4G. This guide will help you get started as quickly and easily
Office of the Government Chief Information Officer. Green Data Centre Practices
Office of the Government Chief Information Officer Green Data Centre Practices Version : 2.0 April 2013 The Government of the Hong Kong Special Administrative Region The contents of this document remain
ENERGY EFFICIENT DATA CENTRES AND STORAGE. Peter James University of Bradford
ENERGY EFFICIENT DATA CENTRES AND STORAGE Peter James University of Bradford ABOUT US 1998 Co-founded world s first NGO on GreenIT EU Expert Advisors/Project Managers on ICT & Energy Efficiency; Environmental
StruxureWare TM Data Center Operation
StruxureWare TM Data Center End to end Management (DCIM) software for monitoring, control of power, cooling, security and energy usage from the building through IT systems Part of StruxureWare for Data
StruxureWare. How to reconcile efficiency and availability in a virtualized data center. for data centers
How to reconcile efficiency and availability in a virtualized data center TM StruxureWare for data centers Soeren Brogaard Jensen 27th of October 2011 Vilnius, Litauen Schneider Electric the global specialist
Monitoring solar PV output
Monitoring solar PV output Introduction Monitoring of your solar PV output is useful to see the actual outputs. This can be measured from the inverter and/or mains using current clamps or pulse meters
Metering and Managing University of Sheffield Data Centres. Chris Cartledge Independent Consultant [email protected]
Metering and Managing University of Sheffield Data Centres Chris Cartledge Independent Consultant [email protected] Summary ICT Electricity Use Footprint Data Centre Electricity Use European
CarbonDecisions. The green data centre. Why becoming a green data centre makes good business sense
CarbonDecisions The green data centre Why becoming a green data centre makes good business sense Contents What is a green data centre? Why being a green data centre makes good business sense 5 steps to
Crowne Plaza Copenhagen Towers The world s greenest hotel
Crowne Plaza Copenhagen Towers The world s greenest hotel The new Crowne Plaza Copenhagen Towers in Copenhagen, has been designed with sustainability in top of mind. The hotel is one of the first hotels
GREEN ICT DELL, OUR SUPPLIERS AND CUSTOMERS
GREEN ICT DELL, OUR SUPPLIERS AND CUSTOMERS Victor C. Smith Senior Strategic Technologist Dell Corporation Ltd. GROWTH EVERY SECOND IN THE CONNECTED AGE 2 new blogs created 4 cell phones purchased 7 personal
Xantrex Solar Monitor Widget. User Guide
Xantrex Solar Monitor Widget User Guide Xantrex Solar Monitor Widget User Guide About Xantrex Xantrex Technology Inc. is a world-leading supplier of advanced power electronics and controls with products
Grid of the Future. Integration of Renewables Energy Storage Smart Grid. Presentation by David Hawkins Lead Renewables Power Engineer Grid Operations
Grid of the Future Integration of Renewables Energy Storage Smart Grid Presentation by David Hawkins Lead Renewables Power Engineer Grid Operations Grid of the Future Current Power System Gen. Trans. Dist.Cust.
Western Australia and the Northern Territory are not connected to the NEM, primarily due to the distance between networks.
Australia has one of the world s longest alternating current (AC) systems, stretching from Port Douglas in Queensland to Port Lincoln in South Australia and across the Bass Strait to Tasmania a distance
A. Title of Lesson: Quantification of Appliance Electricity Consumption at Home. D. Timeframe for entire lesson: 3 classroom sessions of 55 minutes
A. Title of Lesson: Quantification of Appliance Electricity Consumption at Home B. Author: Geoffrey Kavulya C. Audience: 5th -8th grade science students D. Timeframe for entire lesson: 3 classroom sessions
Reducing Data Center Loads for a Large-Scale, Net Zero Office Building
rsed Energy Efficiency & Renewable Energy FEDERAL ENERGY MANAGEMENT PROGRAM Reducing Data Center Loads for a Large-Scale, Net Zero Office Building Energy Efficiency & Renewable Energy Executive summary
A VANTAGE DATA CENTER INFOPAPER. The Open Compute Project + Your Data Center: What you need to know
A VANTAGE DATA CENTER INFOPAPER The Open Compute Project + Your Data Center: What you need to know A VANTAGE DATA CENTER INFOPAPER The Open Compute Project + Your Data Center: What you need to know If
How To Use Softxpand (A Thin Client) On A Pc Or Laptop Or Mac Or Macbook Or Ipad (For A Powerbook)
SoftXpand in Thin Client Environment Prepared by MiniFrame Marketing & Sales Team What is SoftXpand? SoftXpand software turns ANY PC (desktop/server/laptop) into multiple independent workstations. It is
Investor day. November 17, 2010. Power business Julio Rodriguez Executive Vice President
Investor day November 17, 2010 Power business Julio Rodriguez Executive Vice President Power: Business strategic domain Centralized generation Residential Residential Industries Non Residential Transmission
PC Solutions That Mean Business
PC Solutions That Mean Business Desktop and notebook PCs for small business Powered by the Intel Core 2 Duo Processor The Next Big Thing in Business PCs The Features and Performance to Drive Business Success
Smart Energy Consumption and the Smart Grid
Smart Energy Consumption and the Smart Grid Executive Summary The nation s outdated electrical infrastructure is being transformed. Fundamental changes that add intelligence, integrated communications
Energy Harvesting-Based Green Wireless Communication Systems
Energy Harvesting-Based Green Wireless Communication Systems Neelesh B. Mehta Indian Institute of Science (IISc), Bangalore, India Outline A motivating application Energy harvesting overview Two research
Implement Data Center Energy Saving Management with Green Data Center Environment and Energy Performance Indicators
Implement Data Center Energy Saving Management with Green Data Center Environment and Energy Performance Indicators Awareness of environmental protection issues, has many industry types focusing and pursuing
Global Green Data Center Best Practices In Action
Global Green Data Center Best Practices In Action DOUG WASHBURN VICE PRESIDENT & RESEARCH DIRECTOR September 25, 2013 Four questions I will answer 1 Why is green important to your business? 2 Why is green
Temperature & Humidity SMS Alert Controller
Temperature & Humidity Alert Controller METERS 3 simple steps starting the unit: Insert the SIM card Plug in the sensors connectors Connect the AC power cord. Specifications: AC 90~260V Auto Select Internal
Cloud-based aggregation of high-fidelity, distributed meteorological data from unattended low power field devices
Cloud-based aggregation of high-fidelity, distributed meteorological data from unattended low power field devices Presented by Gregg Le Blanc WINData, Inc. We used the cloud. We got data from far away.
Electrical Charge: a type of energy that comes from the flow of charged particles; it allows electrical devices to function.
Unit E: Electrical Applications Chapter 11: Electrical Energy 11.1: Generating Electricity pg. 420 Key Concepts: 1. Electrical energy is generated using a variety of technologies. 2. Electrical energy
Free Cooling in Data Centers. John Speck, RCDD, DCDC JFC Solutions
Free Cooling in Data Centers John Speck, RCDD, DCDC JFC Solutions Why this topic Many data center projects or retrofits do not have a comprehensive analyses of systems power consumption completed in the