1 Protocol for DU 800 Spectrophotometer Make sure that computer is on. The computer is old and will take a long time to start up. System is on if monitor, computer tower and DU 800 have green LED signals by their power buttons. 1. DU 800 Spectrophotometer program icon is located on the left side of the computer screen. Double click to start program. 2. On the upper left- hand of the DU 800 spectrophotometer program, you can choose from a series of programs to run. The default program is Fixed Wavelength. That is the suggested program to use for finding spec readings. 3. Under the Fixed Wavelength lab, a second tab allows you to choose the default method vs the yeast OD600 method of analyzing the spec. For all yeast spec analysis, use the yeast OD600 protocol. 4. Cuvettes used in the spectrophotometer can be found in the top drawer directly behind the machine, along the wall. 5. You must BLANK all procedures before starting readings. Readings without a blank do not mean anything. To create a blank, place 1 ml of the solvent used in preparing samples into the plastic cuvette (ex. Distilled water, YPR/YPD liquid media, LB liquid media).
2 6. Prepare a BLANK as well as up to 5 samples to be analyzed. There are only 6 sample wells. The blank must be inserted into the top well. 7. Each cuvette contains a triangle on the top of one side. This triangle should point toward the left of the machine when inserted into the reading well. Avoid touching the bottom half of the plastic cuvettes to reduce the amount of fingerprints that could interfere with correct wavelength reading.
3 8. Place all cuvettes into reading wells before use. NOTE: you do not have to fill all the wells to run the machine. If you only have one sample to analyze, then fill the blank and first sample well directly below. The other wells can stay empty. 9. Once sample cuvettes have been inserted into wells, close the machine lid. 10. You must turn on the lamps before reading. To turn on the lamps, click on the visible or UV lamp tabs located on the bottom left of the program window. You can use an individual lamp, or both at the same time. Lamps that are on will have RED writing in the program window and orange indicator lights will illuminate on the spectrophotometer below the lid and power indicator. a. TUNGSTEN LAMP=visible b. D2 LAMP=UV NOTE: Lamps should only be on during analysis. After completion of spectrophotometer use, make sure that lamps are turned off. Turn off lamps by clicking on the red lamp tabs. Orange indicator lights should turn off on spectrophotometer. 11. Once all samples, including blank, are inserted into wells and lights have been turned on, CLICK on the BLUE BLK octagon located on the top left of the program window. This blanks the machine to whatever solvent you are using. After
4 blanking is complete, CLICK on the YELLOW READ SIGN for wavelength reading of your samples. The blank should read out to a really small number (it will not be 0.000) The output will show the readings of each sample. 1-1 represents the blank, and each sample after corresponds to the vertical well. 12. You can re- blank at any time by pressing the BLUE BLK octagon. 13. You can save the output readings by clicking on the Save File tab located on the top of the program window, Before leaving the program, please clear all data by pressing the Clear tab located on the top of the program window. 14. After you have cleared your data, Turn off all lamps. 15. Take out cuvettes from machine, you can rinse and reuse cuvettes if you have multiple readings, SAVE YOUR BLANK CUVETTE if further readings are necessary. Dispose of biohazard liquid waste into the liquid waste collection flasks at your workbench and place cuvettes into the orange- bagged steel containers after use.
5 16. Before leaving spectophotometer work area, make sure all cuvettes are out of machine, and that the lid is closed. Make sure all lamps have been turned off. Leave DU800 spectrophotometer program window open and cleared of any data. Leave computer running. Monitor will go into sleep mode after a period of time.
2 Spectrophotometry and the Analysis of Riboflavin
2 Spectrophotometry and the Analysis of Riboflavin Objectives: A) To become familiar with operating the Platereader; B) to learn how to use the Platereader in determining the absorption spectrum of a compound
The Determination of an Equilibrium Constant
The Determination of an Equilibrium Constant Computer 10 Chemical reactions occur to reach a state of equilibrium. The equilibrium state can be characterized by quantitatively defining its equilibrium
Hitachi U-4100 UV-vis-NIR spectrophotometer (341-F)
Hitachi U-4100 UV-vis-NIR spectrophotometer (341-F) Please contact Dr. Amanda Young for training requests and assistance: 979-862-6845, [email protected] Hardware Our spectrophotometer is made up of
EXPERIMENT 11 UV/VIS Spectroscopy and Spectrophotometry: Spectrophotometric Analysis of Potassium Permanganate Solutions.
EXPERIMENT 11 UV/VIS Spectroscopy and Spectrophotometry: Spectrophotometric Analysis of Potassium Permanganate Solutions. Outcomes After completing this experiment, the student should be able to: 1. Prepare
Experiment C-31 Color Absorption
1 Experiment C-31 Color Absorption Objectives To understand the concepts of light waves and color. To investigate how red, green and blue liquids absorb light of different wavelengths. To learn about colorimeter
What s in the Mix? Liquid Color Spectroscopy Lab (Randy Landsberg & Bill Fisher)
What s in the Mix? Liquid Color Spectroscopy Lab (Randy Landsberg & Bill Fisher) Introduction: There is more to a color than a name. Color can tell us lots of information. In this lab you will use a spectrophotometer
EXPERIMENT 5. Molecular Absorption Spectroscopy: Determination of Iron With 1,10-Phenanthroline
EXPERIMENT 5 Molecular Absorption Spectroscopy: Determination of Iron With 1,10-Phenanthroline UNKNOWN Submit a clean, labeled 100-mL volumetric flask to the instructor so that your unknown iron solution
Using the Spectrophotometer
Using the Spectrophotometer Introduction In this exercise, you will learn the basic principals of spectrophotometry and and serial dilution and their practical application. You will need these skills to
Upon completion of this lab, the student will be able to:
1 Learning Outcomes EXPERIMENT B4: CHEMICAL EQUILIBRIUM Upon completion of this lab, the student will be able to: 1) Analyze the absorbance spectrum of a sample. 2) Calculate the equilibrium constant for
First Bytes Programming Lab 2
First Bytes Programming Lab 2 This lab is available online at www.cs.utexas.edu/users/scottm/firstbytes. Introduction: In this lab you will investigate the properties of colors and how they are displayed
CONFIGURING VIRTUAL TERMINAL: This is the screen you will see when you first open Virtual Terminal
CONFIGURING VIRTUAL TERMINAL: This is the screen you will see when you first open Virtual Terminal Before you begin you must configure the Options for Virtual Terminal. Click on the Options drop down menu
Determining the Free Chlorine Content of Swimming Pool Water. HOCl H + + OCl. Evaluation copy
Determining the Free Chlorine Content of Swimming Pool Water Computer 33 Physicians in the nineteenth century used chlorine water as a disinfectant. Upon the discovery that certain diseases were transmitted
Use of Micropipettes
Use of Micropipettes Prior to lab you should understand: The function of micropipettes in the laboratory Basic parts of micropipette What volumes are measured with P, P and P1 micopipettors How to read
Beckman Coulter DTX 880 Multimode Detector Bergen County Technical Schools Stem Cell Lab
Beckman Coulter DTX 880 Multimode Detector Bergen County Technical Schools Stem Cell Lab Room 213 Beckman Coulter DTX 880 Multimode Detector Information The Beckman Coulter DTX 880 Multimode Detector is
CRM Knowledge Base. Contents
Contents Overview:... 2 The Article Record:... 3 Searching for Articles... 3 Quick Search... 3 Article Groups... 5 Using Favorites... 5 Adding New Articles... 6 Maintaining Articles... 8 Groups... 9 Keywords...
Cary 100 Bio UV-Vis Operating Instructions 09/25/2012 S.V.
1234 Hach Hall 515-294-5805 www.cif.iastate.edu Cary 100 Bio UV-Vis Operating Instructions 09/25/2012 S.V. Location: Contact: 1240 Hach Hall Steve Veysey, 1234 Hach Hall Safety All researchers working
Beer's Law: Colorimetry of Copper(II) Solutions
Exercise 11 Page 1 Illinois Central College CHEMISTRY 130 Name: Beer's Law: Colorimetry of Copper(II) Solutions Objectives In this experiment, we will use Beer's Law to determine the unknown concentrations
Determining the Quantity of Iron in a Vitamin Tablet. Evaluation copy
Determining the Quantity of Iron in a Vitamin Tablet Computer 34 As biochemical research becomes more sophisticated, we are learning more about the role of metallic elements in the human body. For example,
School of Chemistry and Chemical Biology Hazardous Waste Management Plan
School of Chemistry and Chemical Biology Hazardous Waste Management Plan SOPs for the disposal of hazardous waste generated in the School of Chemistry and Chemical Biology Updated 29/11/12 Page 1 Contents:
Absorbance Spectrophotometry: Analysis of FD&C Red Food Dye #40
Absorbance Spectrophotometry: Analysis of FD&C Red Food Dye #40 Note: there is a second document that goes with this one! 2046 - Absorbance Spectrophotometry - Calibration Curve Procedure. The second document
Zetasizer Nano-ZS User Instructions
Zetasizer Nano-ZS User Instructions 1. Activate the instrument computer by logging in to the central login system in the service corridor. If needed, log in to the local instrument computer Username: zetasizer.
How to operate the BD FACSCanto flow cytometer
How to operate the BD FACSCanto flow cytometer Preface Dear colleague, the BD FACSCanto flow cytometer is use to operate, however, it is a delicate instrument for measuring fluorescence of single cells.
This training module reviews the CRM home page called the Dashboard including: - Dashboard My Activities tab. - Dashboard Pipeline tab
This training module reviews the CRM home page called the Dashboard including: - Dashboard My Activities tab - Dashboard Pipeline tab - My Meetings Dashlet - My Calls Dashlet - My Calendar Dashlet - My
Step-by-Step Instructions for Setting Up a Paper in APA Format
Step-by-Step Instructions for Setting Up a Paper in APA Format These instructions will help you format all three parts of your paper: 1. the title or cover page 2. the paper 3. the reference page 1. TITLE
16.4.3 Lab: Data Backup and Recovery in Windows XP
16.4.3 Lab: Data Backup and Recovery in Windows XP Introduction Print and complete this lab. In this lab, you will back up data. You will also perform a recovery of the data. Recommended Equipment The
Quantifying Bacterial Concentration using a Calibrated Growth Curve
BTEC 4200 Lab 2. Quantifying Bacterial Concentration using a Calibrated Growth Curve Background and References Bacterial concentration can be measured by several methods, all of which you have studied
Tutorial for Tracker and Supporting Software By David Chandler
Tutorial for Tracker and Supporting Software By David Chandler I use a number of free, open source programs to do video analysis. 1. Avidemux, to exerpt the video clip, read the video properties, and save
HOWTO annotate documents in Microsoft Word
HOWTO annotate documents in Microsoft Word Introduction This guide will help new users markup, make corrections, and track changes in a Microsoft Word document. These instructions are for Word 2007. The
COLORIMETER. Description 0358BT. Figure 1. The Colorimeter
COLORIMETER Description 0358BT Figure 1. The Colorimeter Introduction The Colorimeter is designed to determine the concentration of a solution by analyzing its color intensity. Monochromatic light from
A Beer s Law Experiment
A Beer s Law Experiment Introduction There are many ways to determine concentrations of a substance in solution. So far, the only experiences you may have are acid-base titrations or possibly determining
TM SysAid Chat Guide Document Updated: 10 November 2009
SysAidTM Chat Guide Document Updated: 10 November 2009 Introduction 2 Quick Access to SysAid Chat 3 Enable / Disable the SysAid Chat from the End User Portal. 4 Edit the Chat Settings 5 Chat Automatic
10.3.1.6 Lab - Data Backup and Recovery in Windows XP
5.0 10.3.1.6 Lab - Data Backup and Recovery in Windows XP Introduction Print and complete this lab. In this lab, you will back up data. You will also perform a recovery of the data. Recommended Equipment
ILLUMINATE ASSESSMENT REPORTS REFERENCE GUIDE
ILLUMINATE ASSESSMENT REPORTS REFERENCE GUIDE What are you trying to find? How to find the data in Illuminate How my class answered each question (Response Frequency) 3. Under Reports, click Response Frequency
9.0 Components Description. 10.0 SENTIO MMG System Quick Setup. 10.1 Plugging in Control Unit. 10.2 Attaching Sensor Harness
9.0 Components Description The main components of the SENTIO MMG System consist of the SENTIO MMG Control Unit with preinstalled SENTIO MMG Software and the SENTIO MMG Sensor Harness. The SENTIO MMG Control
Processing Quotes Using ROBO-Agent for Tower JOB AID
Processing Quotes Using ROBO-Agent Job Aid 1 Processing Quotes Using ROBO-Agent for Tower JOB AID Purpose: This job aid will help agencies use ROBO-Agent to run their Quotes through Tower. When: Use this
2 (. 3 4 5 . -,.. -,. 3. : 1 2 3 > 4, :!! 1,, 17 Lt MAX 2 3 4,, > 5.,,, 6 :, :1)! 2)! 7,, 1, :,. 2,, Bottom of steam generator 7 8 9 10 11 12 automatically and this phenomenon will continue for
Smart Sync. Computer Classroom Management Software. What is SMART Sync? Table of Contents
Smart Sync Computer Classroom Management Software What is SMART Sync? SMART Sync software helps instructors manage the computers in their classroom. SMART Sync keeps a student engaged and focused, and
Ultraviolet-Visible (UV-Vis) Spectroscopy Background Information
1 Ultraviolet-Visible (UV-Vis) Spectroscopy Background Information Instructions for the Operation of the Cary 300 Bio UV-Visible Spectrophotometer See the Thermo OMNIC Help reference on page 49. Ultraviolet-Visible
Microsoft Word Track Changes
Microsoft Word Track Changes This document is provided for your information only. You SHOULD NOT upload a document into imedris that contains tracked changes. You can choose to use track changes for your
ibank Quick Start Guide
ibank Quick Start Guide An introductory tutorial for ibank 3, a personal financial management application. 2008 IGG Software, LLC Overview This tutorial will cover these basic program concepts: 1 2 3 4
Bydureon 2 mg powder and solvent for prolonged-release suspension for injection in pre-filled pen How to use Bydureon pre-filled pen
INSTRUCTIONS FOR THE USER Read these instructions carefully before use Bydureon 2 mg powder and solvent for prolonged-release suspension for injection in pre-filled pen How to use Bydureon pre-filled pen
Moving BidMagic to a new system (Backup / Restore Utility)
Moving BidMagic to a new system (Backup / Restore Utility) Moving BidMagic information from one machine to another is easy; it can be done in a few steps. 1. First backup the old system 2. Copy the backed
Appendix C. Vernier Tutorial
C-1. Vernier Tutorial Introduction: In this lab course, you will collect, analyze and interpret data. The purpose of this tutorial is to teach you how to use the Vernier System to collect and transfer
Phosphates (ortho- and total)
INTRODUCTION Phosphates (ortho- and total) Phosphorus is an essential nutrient for all aquatic plants and algae. Only a very small amount is needed, however, so an excess of phosphorus can easily occur.
Guide to using the Bio Rad CFX96 Real Time PCR Machine
Guide to using the Bio Rad CFX96 Real Time PCR Machine Kyle Dobbs and Peter Hansen Table of Contents Overview..3 Setup Reaction Guidelines 4 Starting up the Software 5 Setup Protocol on Software 6 Setup
Reaction Stoichiometry and the Formation of a Metal Ion Complex
Reaction Stoichiometry and the Formation of a Metal Ion Complex Objectives The objectives of this laboratory are as follows: To use the method of continuous variation to determine the reaction stoichiometry
Resource Scheduler (Meeting Room Manager) User s Manual
Resource Scheduler (Meeting Room Manager) User s Manual Resource Scheduler (or Meeting Room Manager) is a web based software package for reserving facilities and equipment. The NS&M web client can be run
Notes on Excel Forecasting Tools. Data Table, Scenario Manager, Goal Seek, & Solver
Notes on Excel Forecasting Tools Data Table, Scenario Manager, Goal Seek, & Solver 2001-2002 1 Contents Overview...1 Data Table Scenario Manager Goal Seek Solver Examples Data Table...2 Scenario Manager...8
CHEM 161: Beer s Law and Analysis of a Sports Drink
CHEM 161: Beer s Law and Analysis of a Sports Drink Introduction Although sunlight appears white, it contains a spectrum of colors. A rainbow actually shows this range of colors in visible light: violet,
TOPAZ. Using Windows XP with service pack 2. GE Security. Supplement Revision A January 15, 2005
Supplement Revision A January 15, 2005 TOPAZ Using Windows XP with service pack 2 12345 SW Leveton Drive Tualatin Oregon 97062 888.437.3287 www.gesecurity.com TOPAZ Using Windows XP with service pack 2
Intellect Platform - The Workflow Engine Basic HelpDesk Troubleticket System - A102
Intellect Platform - The Workflow Engine Basic HelpDesk Troubleticket System - A102 Interneer, Inc. Updated on 2/22/2012 Created by Erika Keresztyen Fahey 2 Workflow - A102 - Basic HelpDesk Ticketing System
Organizational Development Qualtrics Online Surveys for Program Evaluation
The purpose of this training unit is to provide training in an online survey tool known as Qualtrics. Qualtrics is a powerful online survey tool used by many different kinds of professionals to gather
OSM 2007 MONITORING SOFTWARE
OSM 2007 MONITORING SOFTWARE Contents Preparation...3 Software Installation...4 Configuring OSM...6 Connecting a Device...16 Connecting to Station Monitoring Software...19 Troubleshooting...23 Installing
Hyundai Video Pen VP 02 HD8
Hyundai Video Pen VP 02 HD8 一 Important notes at the beginning a. This manual is designed to familiarise you with the operation of this product. Keep these instructions so you can refer to them at any
Chemistry 118 Laboratory University of Massachusetts Boston Beer s Law
Name: LEARNING GOALS: Chemistry 118 Laboratory University of Massachusetts Boston Beer s Law 1. Become familiar with the concept of concentration and molarity. 2. Become familiar with making dilutions
How to use a SMART Board
1 How to use a SMART Board Basic instructions on how to set up the SMART Board and how to use the SMART Board with both PC and Mac laptops. Contents Page 2: SMART Board Set Up Instructions Page 3: SMART
Instructions for Formatting APA Style Papers in Microsoft Word 2010
Instructions for Formatting APA Style Papers in Microsoft Word 2010 To begin a Microsoft Word 2010 project, click on the Start bar in the lower left corner of the screen. Select All Programs and then find
Accessing vlabs using the VMware Horizon View Client for OSX
Accessing vlabs using the VMware Horizon View Client for OSX This document will demonstrate how to download, install, and connect to a virtual lab desktop from a personal Mac OSX computer using the VMware
CHAPTER 461b. SLOT MACHINE TOWER LIGHTS AND ERROR CONDITIONS TECHNICAL STANDARD. 461b.2. Slot machine tower lights and error conditions.
CHAPTER 461b. SLOT MACHINE TOWER LIGHTS AND ERROR CONDITIONS TECHNICAL STANDARD 461b.2. Slot machine tower lights and error conditions. (a) Unless otherwise authorized by the Board, each slot machine must
This guide shows you how to configure each display option within the item editor.
Rank Order Item The Rank Order item is one of several Checkbox Survey question types (click here to view all Checkbox question types). The Rank Order item offers four different display options: Selectable
Diamante WiFi Wireless Communication User Guide. Linksys E1200
Diamante WiFi Wireless Communication User Guide Linksys E1200 Release: February 2012; August 2011; February 2011 Patent Pending. Copyright 2012, Stenograph, L.L.C. All Rights Reserved. Printed in U.S.A.
How to use FTP Commander
FTP (File Transfer Protocol) software can be used to upload files and complete folders to your web server. On the web, there are a number of free FTP programs that can be downloaded and installed onto
Creating a Database in Access
Creating a Database in Access Microsoft Access is a database application. A database is collection of records and files organized for a particular purpose. For example, you could use a database to store
Experiment 13H THE REACTION OF RED FOOD COLOR WITH BLEACH 1
Experiment 13H FV 1/25/2011(2-run) THE REACTION OF RED FOOD COLOR WITH BLEACH 1 PROBLEM: Determine the rate law for the chemical reaction between FD&C Red Dye #3 and sodium hypochlorite. LEARNING OBJECTIVES:
INTRODUCTION TO SPECTROMETRY
Experiment 11 INTRODUCTION TO SPECTROMETRY Portions adapted by Ross S. Nord and Colleagues, Chemistry Department, Eastern Michigan University from ANAL 043, written by Donald F. Clemens and Warren A. McAllister,
Petrel TIPS&TRICKS from SCM
Petrel TIPS&TRICKS from SCM Maps: Knowledge Worth Sharing Map Annotation A map is a graphic representation of some part of the earth. In our industry, it may represent either the surface or sub surface;
How to set up as VPN Network
How to set up as VPN Network 1 Network and Sharing Firstly open the network and sharing centre by opening control panel and selecting Network and Sharing Center. If Network and Sharing cannot be found
SecureIT Plus Firewall Features and Functionality
SecureIT Plus Firewall Features and Functionality Iowa Network Services SecureIT Plus Firewall Page 1 of 11 1.1 Enabling Firewall 1.1.1 Main Settings Once you have installed the firewall and have rebooted
USING WORDPERFECT'S MERGE TO CREATE MAILING LABELS FROM A QUATTRO PRO SPREADSHEET FILE Click on a Step to move to the next Step
USING WORDPERFECT'S MERGE TO CREATE MAILING LABELS FROM A QUATTRO PRO SPREADSHEET FILE Click on a Step to move to the next Step STEP 1: Create or use a Quattro Pro or Excel File. The first row must be
2C: One in a Million. Part 1: Making solutions. Name: Section: Date: Materials
Name: Section: Date: 2C: One in a Million Drinking water can contain up to 1.3 parts per million (ppm) of copper and still be considered safe. What does parts per million mean? Both living things and the
CATIA Tubing and Piping TABLE OF CONTENTS
TABLE OF CONTENTS Introduction...1 Manual Format...2 Tubing and Piping design...3 Log on/off procedures for Windows...4 To log on...4 To logoff...8 Pull-down Menus...9 Edit...9 Insert...12 Tools...13 Analyze...16
Installing S500 Power Monitor Software and LabVIEW Run-time Engine
EigenLight S500 Power Monitor Software Manual Software Installation... 1 Installing S500 Power Monitor Software and LabVIEW Run-time Engine... 1 Install Drivers for Windows XP... 4 Install VISA run-time...
Chapter 5 -- The Spectrophotometric Determination of the ph of a Buffer. NAME: Lab Section: Date: Sign-Off:
Chapter 5 -- The Spectrophotometric Determination of the ph of a Buffer NAME: Lab Section: Date: Sign-Off: Chapter 5 -- The Spectrophotometric Determination of the ph of a Buffer Introduction Weak acids,
This is a training module for Maximo Asset Management V7.1. It demonstrates how to use the E-Audit function.
This is a training module for Maximo Asset Management V7.1. It demonstrates how to use the E-Audit function. Page 1 of 14 This module covers these topics: - Enabling audit for a Maximo database table -
Chem 131A: Absorbance of Riboflavin
Chem 131A: Absorbance of Riboflavin Purpose: The purpose of this experiment is to: 1) Familiarize the student with the use of the HP 8452 diode array spectrophotometer, 2) examine the limitations of the
Software and Settings Instructions
SoelTech Automation Inc. Software and Settings Instructions Select the blue disclosure button that is associated with the network name you want to connect the Mobile GDO to (Blue >). It would normally
Setting your session preferences
What is Aspen? 7 Basic Steps 1 Setting your session preferences 2 Building the simulation 3 Entering the simulation environment 4 Using the workbook 5 Installing Unit Operations 6 Run Your Simulation 7
Point of Sale Procedures. Quick Reference
Point of Sale Procedures Quick Reference Hard Copy Not Controlled Controlled Copy Available On-line Table of Contents How To Charge to Charge Accounts... 1 Closing an Open Check... 2 Creating a Recipe...
900612 ESP -- SURF Center : ESP GUI Users Guide
900612 ESP -- SURF Center : ESP GUI Users Guide This page last changed on Oct 31, 2011 by kgomes. This is a quick sequence of steps to get the user up and running with the ESP GUI application. When you
Microsoft Office Access 2007 Basics
Access(ing) A Database Project PRESENTED BY THE TECHNOLOGY TRAINERS OF THE MONROE COUNTY LIBRARY SYSTEM EMAIL: [email protected] MONROE COUNTY LIBRARY SYSTEM 734-241-5770 1 840 SOUTH ROESSLER
Albright College Self Service
Getting Started Albright College Self Service -To access Self Service go to the Albright College Home page at www.albright.edu and select Self Service from the Quick Links drop down menu. You can also
Microsoft Word 2010 Basics
Microsoft Word 2010 Basics 1. Start Word if the Word 2007 icon is not on the desktop: a. Click Start>Programs>Microsoft Office>Microsoft Word 2007 b. The Ribbon- seen across the top of Microsoft Word.
For paid computer support call 604-518-6695 http://www.netdigix.com [email protected]
Setting up your vpn connection on windows 2000 or XP in continuation from installing x.509 certificate on windows (please do not continue if you have not installed your x.509 certificate): Instructions
LABSHEET 1: creating a table, primary keys and data types
LABSHEET 1: creating a table, primary keys and data types Before you begin, you may want to take a look at the following links to remind yourself of the basics of MySQL and the SQL language. MySQL 5.7
Lession: 2 Animation Tool: Synfig Card or Page based Icon and Event based Time based Pencil: Synfig Studio: Getting Started: Toolbox Canvas Panels
Lession: 2 Animation Tool: Synfig In previous chapter we learn Multimedia and basic building block of multimedia. To create a multimedia presentation using these building blocks we need application programs
User Guide. Printing, Copying and Scanning
User Guide Printing, Copying and Scanning A few important things to know ( for successful printing, copying and scanning) 1. You will need sufficient credit on your printing account to release your printing.
SMART Board Tips & Tricks (version 9.0) Getting Started. SMART Tools vs. SMART Notebook software
SMART Board Tips & Tricks (version 9.0) Getting Started SMART Tools vs. SMART Notebook software Click the SMART Board icon (in the system tray at the bottom right of your screen) to access the SMART Board
Inpatient Cerner Navigation and Documentation For Nursing Students
Inpatient Cerner Navigation and Documentation For Nursing Students Audience Note: Purpose: Objectives: Cerner PowerChart training is for all students in the following inpatient areas Med/Surg, OSNO, Oncology,
Phosphorus Analyzer Procedure Last updated: 8.7.15. A. Introduction
Phosphorus Analyzer Procedure Last updated: 8.7.15 A. Introduction The phosphorus analyzer can be used to measure soluble reactive phosphorus (SRP) aka orthophosphate (PO 3-4 ) only. Additionally, this
Making Visio Diagrams Come Alive with Data
Making Visio Diagrams Come Alive with Data An Information Commons Workshop Making Visio Diagrams Come Alive with Data Page Workshop Why Add Data to A Diagram? Here are comparisons of a flow chart with
DSL Installation Guide
DSL Installation Guide Thank you for choosing Integra Telecom s DSL service! Introduction This guide will walk you through the DSL installation process and will help you configure a computer to access
For additional how to tips go to: http://support.perfectweddingguide.com
How to use your PWG leads and PWGMailer programs For additional how to tips go to: http://support.perfectweddingguide.com Generating Leads on PWG.com 1. First you will need to log onto your vendor account
Experiment #5: Qualitative Absorption Spectroscopy
Experiment #5: Qualitative Absorption Spectroscopy One of the most important areas in the field of analytical chemistry is that of spectroscopy. In general terms, spectroscopy deals with the interactions
DiPOS User Manual. Tel: 510-770-1388. Fax: 510-257-1610. [email protected]. Address: 44835 Industrial Dr., Fremont, CA 94538
DiPOS User Manual Tel: 510-770-1388 Fax: 510-257-1610 Email: Website: [email protected] www.dinatouch.com Address: 44835 Industrial Dr., Fremont, CA 94538 Table Status: DiPOS User Manual a. White Empty
Creating an Address Book Database
Creating an Address Book Database February 9, 2011 Copyright 2011 by World Class CAD, LLC. All Rights Reserved. Purpose of the Address Book Contains professional contacts Database is computer based (digital)
Abstract. For notes detailing the changes in each release, see the MySQL for Excel Release Notes. For legal information, see the Legal Notices.
MySQL for Excel Abstract This is the MySQL for Excel Reference Manual. It documents MySQL for Excel 1.3 through 1.3.6. Much of the documentation also applies to the previous 1.2 series. For notes detailing
PI Budget Planning Tool
PI Budget Planning Tool WHAT is the PI Budget Planning Tool? The PI Budget Planning Tool is an application that will be delivered in a series of releases that will increase in feature and function over