Ultraviolet-Visible (UV-Vis) Spectroscopy Background Information

Save this PDF as:
 WORD  PNG  TXT  JPG

Size: px
Start display at page:

Download "Ultraviolet-Visible (UV-Vis) Spectroscopy Background Information"

Transcription

1 1 Ultraviolet-Visible (UV-Vis) Spectroscopy Background Information Instructions for the Operation of the Cary 300 Bio UV-Visible Spectrophotometer See the Thermo OMNIC Help reference on page 49. Ultraviolet-Visible (UV-Vis) Spectroscopy Background Information The ultraviolet-visible (UV-Vis) spectrophotometer is an instrument commonly used in the laboratory that analyzes compounds in the ultraviolet (UV) and visible (Vis) regions of the electromagnetic spectrum. Unlike infrared spectroscopy (which looks at vibrational motions), ultraviolet-visible spectroscopy looks at electronic transitions. It allows one to determine the wavelength and maximum absorbance of compounds. From the absorbance information and using a relationship known as Beer s Law (A = εbc, where A = absorbance, ε = molar extinction coefficient, b = path length, and c = concentration), one is able to determine either the concentration of a sample if the molar extinction coefficient is known, or the molar absorptivity, if the concentration is known (Wade ). Molar extinction coefficients are specific to particular compounds, therefore UV-Vis spectroscopy can aid one in determining an unknown compound s identity. Furthermore, the energy of a compound can be ascertained from this technology by using the equation E = hc/λ (where E = energy, h = Planck s constant, c = speed of light, and λ = wavelength). Since photons travel at the speed of light, and h and c are constants, one can find the energy (Wade 501).

2 2 Cary 300 Bio UV-Visible Spectrophotometer Be sure to turn on the UV-Vis at least 20 minutes before you intend on running samples; it needs to warm up properly in order to function accurately. Selecting a Wavelength to Run Your Experiment At If your instructor has not given you a specific wavelength to run your samples at, you must determine the appropriate wavelength by performing a scan. From the Start menu, click on Programs Cary WinUV Scan. On the top toolbar options, click on the Setup tab. o Under the Cary tab, type in your start and stop parameters (what region you want the instrument to scan). Click OK. o Under the Options tab, select whether you want to scan in the UV, Vis, or UV-Vis range. Use a Kimwipe to wipe down the sides of the cuvette and be careful to avoid touching the sides of the cuvette when putting it in the instrument. Zero the instrument by placing blanks (your solvent) in cells 1 and 7. On the cuvette, the side with the arrow should be facing the left (there is a yellow arrow on the top of the UV/Vis indicating this) when you insert them in the cells. Having the cuvettes facing the same direction will ensure that the path

3 3 lengths are the same. Close the lid on the UV-Vis and hit the Zero button on the left-hand side of the screen. o The box in the upper left-hand corner will show that the instrument has been zeroed by displaying an absorbance of The absorbance reading may vary slightly (bounce above and below 0.000); this is due to noise and is normal. To run a sample, take the blank cuvette out of cell 1 and replace it with the sample to be run. Leave the other blank in cell 7 for all subsequent runs. Click Start. Saving/Retrieving Data Analysis To save data, go to File Save Data As. Enter a filename and click Save. Your file will be saved in the.bsw format. To open saved data, go to File Open Data select the desired file. Once a plot has been drawn, you can use the several buttons on the toolbar to manipulate the graph. Cursor mode Free mode : the cursor (which appears as a +) can be moved in any direction without any restrictions. Track mode : along with the cursor, a set of intersecting lines will appear. As you drag the cursor to the left or right, the horizontal line rides along the line produced by the data points. You can monitor the X and Y values that result from specific data points by looking in the right-hand corner beneath the graph. Track Preferences This displays the names of the lines generated from your data points and their corresponding colors and filenames. Graph Preferences This allows you to change the color and width of the axes, as well as the font and the way the data is plotted (i.e. dots or solid lines). Scale Graph This allows you to change the scale of the graph by typing in the area you would like to focus on. Add Label

4 4 This feature allows you to add labels to your graph. Unless otherwise instructed, when running samples do not use the baseline correction feature. This uses an already-stored file as the baseline for your sample. Simple Reads This selection allows you to take a measurement at one wavelength. Enter Setup and type in the wavelength you desire to read your sample at. Normally, the UV-Vis is setup to read in absorbance; if you wish to change the setting to percent transmittance, click the %T button. Running the sample: o Zero the instrument, then place your sample in the UV-Vis and press the Read button. Running Multiple Samples in Scan Mode Cell changer From the Start menu, click on Programs Cary WinUV Scan. Under the Setup tab select the following settings: o Cary set the start/stop wavelengths OK. o Options UV-Vis o Baseline Correction None o Accessory 1 Use Cell Changer Select Cells. Check the boxes of the cells you want to use OK. Do not check the cell box that you have your blanks in or they will be used as samples.

5 5 Concentration Zero the instrument. Click the Start button. A Save As box appears; create a filename and click Save. The Cell Loading Guide box will appear indicating the active cells; clicking in the desired cell box will allow you to change the name of the sample. Traces will be drawn starting with the first cell clicked. With varying concentrations you will be able to see the various intensities corresponding to the concentrations. Moving the cursor over the desired trace and clicking the left mouse button will indicate the sample number or name that you have designated. From the Start menu, click on Programs Cary WinUV Concentration. Go Setup ; a Setup box then appears with tabs. To set up the parameters for your experiment, fill in the appropriate tabs. Setup Cary tab: o Wavelength (nm) type in the desired wavelength. o Ave. Time (sec) a good starting point is o SBW (nm) this is the spectral bandwidth. It is automatically set at 1.5; this value may need to be adjusted. o Replicates set this value at 1 unless otherwise instructed. o Sample/Std Averaging should not be clicked unless instructed. o Y Mode Abs should be clicked. o The Y Min and Y Max fields need to be set. Standards tab: o Standards box: The Calibrate during run box should be checked. Change Units to the appropriate labeling by the drop-down menu. From the Standards drop-down menu, adjust accordingly. The box below should then change to the correct number of standards as you indicated. In the Std/Conc box, change the concentration so that it correctly corresponds to your standards. o Fit Type box: Select the appropriate curve fitting for your method. Min R 2 should be set at to start. Samples tab: o Sample Names box:

6 6 Number of Samples can be adjusted with the toggle; the box below should then change accordingly. You can change the name of the sample by clicking in the box and typing. o Weight/Volume Corrections Enter values as needed. Options tab: o In the Source box: The Autolamps off box should be unchecked. The UV-Vis button should be selected. Source Changeover (nm) is automatically set at 350 nm. Ask your instructor if this needs adjustment. o In the Beam Mode box: The Normal button should be clicked. Double Beam should be toggled on. Accessories 1 tab o Cells box this allows you to use a cell changer or well plate. If you do not want to run multiple samples at the same time, the Use Cell Changer box should not be checked. If you do want to run multiple samples, check the Use Cell Changer box and refer to the instructions for this feature as previously mentioned. o Temperature box: The Automatic Temperature Setting box should not be checked unless the method you are using requires the samples to be above room temperature. o RBA box The Use RBA box should not be checked. Accessories 2 tab: o None of the boxes in this tab should be selected. Samplers tab: o Nothing should be checked. o The drop-down box should read None. Reports tab: o This will probably not be used unless instructed by your professor. Autostore tab: o The Storage on (Prompt at end) toggle should be highlighted. After all of the parameters have been set, press OK. Running Standards/Samples Zero the instrument as previously indicated.

7 7 Put the first standard in the cell holder and press Start. A Standard/Sample Selection will appear. Select the standards and samples for your calibration so that they are in the Selected for Analysis portion of the box. Move any other solutions over to the Solutions Available box by using the arrows. and will move the selected standards or samples to the left side (Solutions Available) and right side (Selected for Analysis), respectively. and will move all standards and solutions to the left and right side, respectively. When the standards and samples are in the correct positions, press OK. o A Present Standard box will appear. Press OK if it indicates that the correct standard is selected. Once a reading has completed, the Present Standard box will appear again indicating the next standard. Repeat until all standards have been run. After the standards have been run, a calibration curve (or line) will be drawn and a correlation coefficient will be displayed. In some cases, however, a box labeled Concentration will appear saying, Min R 2 test failed. This means that your data did not fit with the indicated correlation coefficient (i.e. you had bad data). Proceed by pressing OK. A Standards box will appear saying, There is no valid calibration. Proceed in Abs? By pressing OK, the absorbance of subsequent samples will be measured, but no concentration will result since the calibration failed. A Present Sample box then appears. Follow the instructions as with the standards. Closing Down Save your data as needed and exit out of the program. Log-off. Turn off the instrument.

8 8 Absorbance reading Toolbar for analysis Changes to a Start button when online Wavelength

Cary 100 Bio UV-Vis Operating Instructions 09/25/2012 S.V.

Cary 100 Bio UV-Vis Operating Instructions 09/25/2012 S.V. 1234 Hach Hall 515-294-5805 www.cif.iastate.edu Cary 100 Bio UV-Vis Operating Instructions 09/25/2012 S.V. Location: Contact: 1240 Hach Hall Steve Veysey, 1234 Hach Hall Safety All researchers working

More information

Info Note UV-VIS Nomenclature and Units

Info Note UV-VIS Nomenclature and Units Info Note 804: Ultraviolet-visible spectroscopy or ultraviolet-visible spectrophotometry (UV/VIS) involves the spectroscopy of photons in the UV-visible region. It uses light in the visible and adjacent

More information

Shimadzu UV-VIS User s Guide

Shimadzu UV-VIS User s Guide Shimadzu UV-VIS User s Guide 1) Push the F4 button on the UV-VIS instrument keypad. This will enable PC control. Push the F4 Button 2) Log into the UV-VIS software with your username and password. 3) After

More information

Using the Spectrophotometer

Using the Spectrophotometer Using the Spectrophotometer Introduction In this exercise, you will learn the basic principals of spectrophotometry and and serial dilution and their practical application. You will need these skills to

More information

EXPERIMENT 5. Molecular Absorption Spectroscopy: Determination of Iron With 1,10-Phenanthroline

EXPERIMENT 5. Molecular Absorption Spectroscopy: Determination of Iron With 1,10-Phenanthroline EXPERIMENT 5 Molecular Absorption Spectroscopy: Determination of Iron With 1,10-Phenanthroline UNKNOWN Submit a clean, labeled 100-mL volumetric flask to the instructor so that your unknown iron solution

More information

EXPERIMENT 11 UV/VIS Spectroscopy and Spectrophotometry: Spectrophotometric Analysis of Potassium Permanganate Solutions.

EXPERIMENT 11 UV/VIS Spectroscopy and Spectrophotometry: Spectrophotometric Analysis of Potassium Permanganate Solutions. EXPERIMENT 11 UV/VIS Spectroscopy and Spectrophotometry: Spectrophotometric Analysis of Potassium Permanganate Solutions. Outcomes After completing this experiment, the student should be able to: 1. Prepare

More information

Austin Peay State University Department of Chemistry Chem 1111. The Use of the Spectrophotometer and Beer's Law

Austin Peay State University Department of Chemistry Chem 1111. The Use of the Spectrophotometer and Beer's Law Purpose To become familiar with using a spectrophotometer and gain an understanding of Beer s law and it s relationship to solution concentration. Introduction Scientists use many methods to determine

More information

User guide for Cary 5000 absorption spectrometer with external DRA 1800 attachment.

User guide for Cary 5000 absorption spectrometer with external DRA 1800 attachment. User guide for Cary 5000 absorption spectrometer with external DRA 1800 attachment. (last updated 03/17/2016) This guide is for use of the Cary 5000 with the DRA only. For use without the DRA as a standard

More information

6850 PRISM PC Software

6850 PRISM PC Software 6850 PRISM PC Software Operating Manual REV A/06-12 Contents SECTION 1 Introduction... 4 2 1.1 PC SOFTWARE DESCRIPTION... 4 1.2 REQUIRED PC SPECIFICATION... 4 SECTION 2 Installation... 4 2.1 UNPACKING...

More information

Chemistry 111 Lab: Intro to Spectrophotometry Page E-1

Chemistry 111 Lab: Intro to Spectrophotometry Page E-1 Chemistry 111 Lab: Intro to Spectrophotometry Page E-1 SPECTROPHOTOMETRY Absorption Measurements & their Application to Quantitative Analysis study of the interaction of light (or other electromagnetic

More information

Upon completion of this lab, the student will be able to:

Upon completion of this lab, the student will be able to: 1 Learning Outcomes EXPERIMENT B4: CHEMICAL EQUILIBRIUM Upon completion of this lab, the student will be able to: 1) Analyze the absorbance spectrum of a sample. 2) Calculate the equilibrium constant for

More information

Beckman Coulter DU 800 Spectrophotometer Bergen County Technical Schools Stem Cell Lab

Beckman Coulter DU 800 Spectrophotometer Bergen County Technical Schools Stem Cell Lab Beckman Coulter DU 800 Spectrophotometer Bergen County Technical Schools Stem Cell Lab Room 213 Beckman Coulter DU 800 Spectrophotometer Safety Sheet 1. Samples should be handled according to good laboratory

More information

UV/Vis Spectroscopy. Varka Evi-Maria Ph.D. Chemist AUTH Thessaloniki 2012

UV/Vis Spectroscopy. Varka Evi-Maria Ph.D. Chemist AUTH Thessaloniki 2012 UV/Vis Spectroscopy Varka Evi-Maria Ph.D. Chemist AUTH Thessaloniki 2012 Introduction of Spectroscopy The structure of new synthesised molecules or isolated compounds from natural sources in the lab must

More information

LAB. THE SPECTROPHOTOMETER

LAB. THE SPECTROPHOTOMETER Name AP Biology Period Date LAB. THE SPECTROPHOTOMETER INTRODUCTION: A spectrophotometer is a valuable instrument in biology. It allows us to measure and compare the concentration of materials in solution

More information

Energy (J) -8E-19 -1.2E-18 -1.6E-18 -2E-18

Energy (J) -8E-19 -1.2E-18 -1.6E-18 -2E-18 Spectrophotometry Reading assignment:. http://en.wikipedia.org/wiki/beer-lambert_law Goals We will study the spectral properties of a transition metal-containing compound. We will also study the relationship

More information

2 Spectrophotometry and the Analysis of Riboflavin

2 Spectrophotometry and the Analysis of Riboflavin 2 Spectrophotometry and the Analysis of Riboflavin Objectives: A) To become familiar with operating the Platereader; B) to learn how to use the Platereader in determining the absorption spectrum of a compound

More information

VISIBLE SPECTROSCOPY

VISIBLE SPECTROSCOPY VISIBLE SPECTROSCOPY Visible spectroscopy is the study of the interaction of radiation from the visible part (λ = 380-720 nm) of the electromagnetic spectrum with a chemical species. Quantifying the interaction

More information

Reaction Stoichiometry and the Formation of a Metal Ion Complex

Reaction Stoichiometry and the Formation of a Metal Ion Complex Reaction Stoichiometry and the Formation of a Metal Ion Complex Objectives The objectives of this laboratory are as follows: To use the method of continuous variation to determine the reaction stoichiometry

More information

A Beer s Law Experiment

A Beer s Law Experiment A Beer s Law Experiment Introduction There are many ways to determine concentrations of a substance in solution. So far, the only experiences you may have are acid-base titrations or possibly determining

More information

Table of Contents. Graphing with Excel 1

Table of Contents. Graphing with Excel 1 Table of Contents Graphing with Excel 1 1. Graphing Data 1.1. Starting the Chart Wizard 1.2. Selecting the Data 1.3. Selecting the Chart Options 1.3.1. Titles Tab 1.3.2. Axes Tab 1.3.3. Gridlines Tab 1.3.4.

More information

QUANTITATIVE INFRARED SPECTROSCOPY. Willard et. al. Instrumental Methods of Analysis, 7th edition, Wadsworth Publishing Co., Belmont, CA 1988, Ch 11.

QUANTITATIVE INFRARED SPECTROSCOPY. Willard et. al. Instrumental Methods of Analysis, 7th edition, Wadsworth Publishing Co., Belmont, CA 1988, Ch 11. QUANTITATIVE INFRARED SPECTROSCOPY Objective: The objectives of this experiment are: (1) to learn proper sample handling procedures for acquiring infrared spectra. (2) to determine the percentage composition

More information

University of Wisconsin Chemistry 524 Spectroscopic Applications (GFAA, ICP, UV/Vis, Fluorescence)

University of Wisconsin Chemistry 524 Spectroscopic Applications (GFAA, ICP, UV/Vis, Fluorescence) University of Wisconsin Chemistry 524 Spectroscopic Applications (GFAA, ICP, UV/Vis, Fluorescence) For this laboratory exercise, you will explore a variety of spectroscopic methods used in an analytical

More information

Trial 9 No Pill Placebo Drug Trial 4. Trial 6.

Trial 9 No Pill Placebo Drug Trial 4. Trial 6. An essential part of science is communication of research results. In addition to written descriptions and interpretations, the data are presented in a figure that shows, in a visual format, the effect

More information

Hitachi U-4100 UV-vis-NIR spectrophotometer (341-F)

Hitachi U-4100 UV-vis-NIR spectrophotometer (341-F) Hitachi U-4100 UV-vis-NIR spectrophotometer (341-F) Please contact Dr. Amanda Young for training requests and assistance: 979-862-6845, amandayoung@tamu.edu Hardware Our spectrophotometer is made up of

More information

USING EXCEL ON THE COMPUTER TO FIND THE MEAN AND STANDARD DEVIATION AND TO DO LINEAR REGRESSION ANALYSIS AND GRAPHING TABLE OF CONTENTS

USING EXCEL ON THE COMPUTER TO FIND THE MEAN AND STANDARD DEVIATION AND TO DO LINEAR REGRESSION ANALYSIS AND GRAPHING TABLE OF CONTENTS USING EXCEL ON THE COMPUTER TO FIND THE MEAN AND STANDARD DEVIATION AND TO DO LINEAR REGRESSION ANALYSIS AND GRAPHING Dr. Susan Petro TABLE OF CONTENTS Topic Page number 1. On following directions 2 2.

More information

Beer's Law: Colorimetry of Copper(II) Solutions

Beer's Law: Colorimetry of Copper(II) Solutions Exercise 11 Page 1 Illinois Central College CHEMISTRY 130 Name: Beer's Law: Colorimetry of Copper(II) Solutions Objectives In this experiment, we will use Beer's Law to determine the unknown concentrations

More information

Instructions for Formatting APA Style Papers in Microsoft Word 2010

Instructions for Formatting APA Style Papers in Microsoft Word 2010 Instructions for Formatting APA Style Papers in Microsoft Word 2010 To begin a Microsoft Word 2010 project, click on the Start bar in the lower left corner of the screen. Select All Programs and then find

More information

Experiment #5: Qualitative Absorption Spectroscopy

Experiment #5: Qualitative Absorption Spectroscopy Experiment #5: Qualitative Absorption Spectroscopy One of the most important areas in the field of analytical chemistry is that of spectroscopy. In general terms, spectroscopy deals with the interactions

More information

SPECTROPHOTOMETRY. Blue. Orange

SPECTROPHOTOMETRY. Blue. Orange Appendix I FV /26/5 SPECTROPHOTOMETRY Spectrophotometry is an analytical technique used to measure the amount of light of a particular wavelength absorbed by a sample in solution. This measurement is then

More information

Reading: Graphing Techniques Revised 3/6/12 GRAPHING TECHNIQUES

Reading: Graphing Techniques Revised 3/6/12 GRAPHING TECHNIQUES GRAPHING TECHNIQUES Mathematical relationships between variables are determined by graphing experimental data. For example, the linear relationship between the concentration and the absorption of dilute

More information

Using Microsoft Excel

Using Microsoft Excel Using Microsoft Excel Key skill [Where it is introduced] To open MS Excel. To open an existing spreadsheet. How to do it! Start > All Programs > Microsost Office > Microsoft Office Excel 2003 File > Open

More information

Ultraviolet Spectroscopy

Ultraviolet Spectroscopy Ultraviolet Spectroscopy The wavelength of UV and visible light are substantially shorter than the wavelength of infrared radiation. The UV spectrum ranges from 100 to 400 nm. A UV-Vis spectrophotometer

More information

Chapter 5 -- The Spectrophotometric Determination of the ph of a Buffer. NAME: Lab Section: Date: Sign-Off:

Chapter 5 -- The Spectrophotometric Determination of the ph of a Buffer. NAME: Lab Section: Date: Sign-Off: Chapter 5 -- The Spectrophotometric Determination of the ph of a Buffer NAME: Lab Section: Date: Sign-Off: Chapter 5 -- The Spectrophotometric Determination of the ph of a Buffer Introduction Weak acids,

More information

Using Excel to a Graph System of Equations

Using Excel to a Graph System of Equations Using Excel to a Graph System of Equations Level: Goal: OBS To become familiar with Microsoft Excel and the Chart Wizard in order to create graphs of systems of equations on the computer. Learning Outcomes:

More information

UV/VIS/IR SPECTROSCOPY ANALYSIS OF NANOPARTICLES

UV/VIS/IR SPECTROSCOPY ANALYSIS OF NANOPARTICLES UV/VIS/IR SPECTROSCOPY ANALYSIS OF NANOPARTICLES SEPTEMBER 2012, V 1.1 4878 RONSON CT STE K SAN DIEGO, CA 92111 858-565 - 4227 NANOCOMPOSIX.COM Note to the Reader: We at nanocomposix have published this

More information

Problem Set 6 UV-Vis Absorption Spectroscopy. 13-1. Express the following absorbances in terms of percent transmittance:

Problem Set 6 UV-Vis Absorption Spectroscopy. 13-1. Express the following absorbances in terms of percent transmittance: Problem Set 6 UV-Vis Absorption Spectroscopy 13-1. Express the following absorbances in terms of percent transmittance: a 0.051 b 0.918 c 0.379 d 0.261 e 0.485 f 0.072 A = log P o /P = log1/t = - log T

More information

The Determination of the Percent of Salicylic Acid in Aspirin

The Determination of the Percent of Salicylic Acid in Aspirin Salicylic acid The Determination of the Percent of Salicylic Acid in Aspirin Aspirin or acetylsalicylic acid, may be prepared by the reaction of salicylic acid and either acetic acid or acetic anhydride

More information

Spectrophotometry and the Beer-Lambert Law: An Important Analytical Technique in Chemistry

Spectrophotometry and the Beer-Lambert Law: An Important Analytical Technique in Chemistry Spectrophotometry and the Beer-Lambert Law: An Important Analytical Technique in Chemistry Jon H. Hardesty, PhD and Bassam Attili, PhD Collin College Department of Chemistry Introduction: In the last lab

More information

Scientific Graphing in Excel 2010

Scientific Graphing in Excel 2010 Scientific Graphing in Excel 2010 When you start Excel, you will see the screen below. Various parts of the display are labelled in red, with arrows, to define the terms used in the remainder of this overview.

More information

Instructions for Formatting MLA Style Papers in Microsoft Word 2010

Instructions for Formatting MLA Style Papers in Microsoft Word 2010 Instructions for Formatting MLA Style Papers in Microsoft Word 2010 To begin a Microsoft Word 2010 project, click on the Start bar in the lower left corner of the screen. Select All Programs and then find

More information

Spreadsheets and Laboratory Data Analysis: Excel 2003 Version (Excel 2007 is only slightly different)

Spreadsheets and Laboratory Data Analysis: Excel 2003 Version (Excel 2007 is only slightly different) Spreadsheets and Laboratory Data Analysis: Excel 2003 Version (Excel 2007 is only slightly different) Spreadsheets are computer programs that allow the user to enter and manipulate numbers. They are capable

More information

Using Google Docs to Create Student Digital Portfolios

Using Google Docs to Create Student Digital Portfolios Using Google Docs to Create Student Digital Portfolios 1) In your Drive, create a new folder and title it Student Digital Portfolios. Hint: Your Drive may say Create instead of New. 2) From Google Drive,

More information

Fixplot Instruction Manual. (data plotting program)

Fixplot Instruction Manual. (data plotting program) Fixplot Instruction Manual (data plotting program) MANUAL VERSION2 2004 1 1. Introduction The Fixplot program is a component program of Eyenal that allows the user to plot eye position data collected with

More information

The Determination of an Equilibrium Constant

The Determination of an Equilibrium Constant The Determination of an Equilibrium Constant Computer 10 Chemical reactions occur to reach a state of equilibrium. The equilibrium state can be characterized by quantitatively defining its equilibrium

More information

Appendix C. Vernier Tutorial

Appendix C. Vernier Tutorial C-1. Vernier Tutorial Introduction: In this lab course, you will collect, analyze and interpret data. The purpose of this tutorial is to teach you how to use the Vernier System to collect and transfer

More information

Beckman Coulter DTX 880 Multimode Detector Bergen County Technical Schools Stem Cell Lab

Beckman Coulter DTX 880 Multimode Detector Bergen County Technical Schools Stem Cell Lab Beckman Coulter DTX 880 Multimode Detector Bergen County Technical Schools Stem Cell Lab Room 213 Beckman Coulter DTX 880 Multimode Detector Information The Beckman Coulter DTX 880 Multimode Detector is

More information

Practice Problem Set 7 Applications of UV-Vis Absorption Spectroscopy

Practice Problem Set 7 Applications of UV-Vis Absorption Spectroscopy Practice Problem Set 7 Applications of UV-Vis Absorption Spectroscopy 1. π π Transition is the most concenient and useful transition in UV-Vis Spectroscopy. Why? In σ σ* transitions The high energy required

More information

Measurement: Straight Lines/ Standard Curves

Measurement: Straight Lines/ Standard Curves Measurement: Straight Lines/ Standard Curves URL: http://mathbench.org.au/measurement/straight-lines-standard-curves/ Learning Outcomes After completing this module you should be able to: Describe the

More information

Shimadzu UV-1700 UV/Vis Spectrometer Updated July 13, 2010

Shimadzu UV-1700 UV/Vis Spectrometer Updated July 13, 2010 Shimadzu UV-1700 UV/Vis Spectrometer Updated July 13, 2010 Instrument instructions can be found at: http://academic.bowdoin.edu/chemistry/resources/instructions.shtml If you have any problems with the

More information

A COMPLEX IRON SALT & BEER S LAW

A COMPLEX IRON SALT & BEER S LAW A OMPLEX IRO SALT & BEER S LAW LABORATORY OTEBOOK Objectives, hemical & Equipment Tables, and Procedures & Observations should all be entered into your EL. All spectra files should be attached in the Procedures

More information

Creating a PowerPoint Poster using Windows

Creating a PowerPoint Poster using Windows Creating a PowerPoint Poster using Windows Copyright 2001 Michael Dougherty (michael@nmsu.edu) Purpose The purpose of this tutorial is to illustrate how to create a 3 x 4 ft. poster using PowerPoint. This

More information

SPECTROPHOTOMETRY. PRINCIPLE AND APPLICATIONS

SPECTROPHOTOMETRY. PRINCIPLE AND APPLICATIONS EUROPEAN UNION GOVERNMENT OF ROMANIA GOVERNMENT OF THE REPUBLIC OF SERBIA Structural Funds 2007-2013 SPECTROPHOTOMETRY. PRINCIPLE AND APPLICATIONS As.dr.ing. ADRIAN EUGEN CIOABLA WORKSHOP 05 06 September

More information

Experiment 6: Determination of the Equilibrium Constant for Iron Thiocyanate Complex

Experiment 6: Determination of the Equilibrium Constant for Iron Thiocyanate Complex Experiment 6: Determination of the Equilibrium Constant for Iron Thiocyanate Complex The data for this lab will be taken as a class to get one data set for the entire class. I. Introduction A. The Spectrophotometer

More information

Using a Spectrophotometer

Using a Spectrophotometer Introduction: Spectrophotometry Using a Spectrophotometer Many kinds of molecules interact with or absorb specific types of radiant energy in a predictable fashion. For example, when while light illuminates

More information

In this example, Mrs. Smith is looking to create graphs that represent the ethnic diversity of the 24 students in her 4 th grade class.

In this example, Mrs. Smith is looking to create graphs that represent the ethnic diversity of the 24 students in her 4 th grade class. Creating a Pie Graph Step-by-step directions In this example, Mrs. Smith is looking to create graphs that represent the ethnic diversity of the 24 students in her 4 th grade class. 1. Enter Data A. Open

More information

EXPERIMENT 2 Reaction Order

EXPERIMENT 2 Reaction Order EXPERIMENT 2 Reaction Order Introduction How a reaction progresses over time is an indication of its reaction order. In the rate laws, (Rate = k[a] m [B] n ), found in the first experiment, you calculated

More information

Analysis of Riboflavin in a Vitamin Pill by Fluorescence Spectroscopy**

Analysis of Riboflavin in a Vitamin Pill by Fluorescence Spectroscopy** Analysis of Riboflavin in a Vitamin Pill by Fluorescence Spectroscopy** Objectives In this lab, you will use fluorescence spectroscopy to determine the mass and percentage of riboflavin in a vitamin pill.

More information

Entering data and doing repetitive calculations with Excel

Entering data and doing repetitive calculations with Excel Entering data and doing repetitive calculations with Excel Start by entering preliminary data in columns. Label each column. If you need to do repetitive calculations on your data before you make a graph,

More information

Lab #11: Determination of a Chemical Equilibrium Constant

Lab #11: Determination of a Chemical Equilibrium Constant Lab #11: Determination of a Chemical Equilibrium Constant Objectives: 1. Determine the equilibrium constant of the formation of the thiocyanatoiron (III) ions. 2. Understand the application of using a

More information

How to Format Your Thesis or Dissertation

How to Format Your Thesis or Dissertation How to Format Your Thesis or Dissertation How to view the formatting marks in your document... 2 How to reset your toolbars... 3 How to set the margins... 4 How to double space your document... 7 How to

More information

Creating a Poster in PowerPoint 2010. A. Set Up Your Poster

Creating a Poster in PowerPoint 2010. A. Set Up Your Poster View the Best Practices in Poster Design located at http://www.emich.edu/training/poster before you begin creating a poster. Then in PowerPoint: (A) set up the poster size and orientation, (B) add and

More information

Absorbance Spectrophotometry: Analysis of FD&C Red Food Dye #40 Calibration Curve Procedure

Absorbance Spectrophotometry: Analysis of FD&C Red Food Dye #40 Calibration Curve Procedure Absorbance Spectrophotometry: Analysis of FD&C Red Food Dye #40 Calibration Curve Procedure Note: there is a second document that goes with this one! 2046 - Absorbance Spectrophotometry. Make sure you

More information

Using Microsoft Excel to Plot and Analyze Kinetic Data

Using Microsoft Excel to Plot and Analyze Kinetic Data Entering and Formatting Data Using Microsoft Excel to Plot and Analyze Kinetic Data Open Excel. Set up the spreadsheet page (Sheet 1) so that anyone who reads it will understand the page (Figure 1). Type

More information

Sample Table. Columns. Column 1 Column 2 Column 3 Row 1 Cell 1 Cell 2 Cell 3 Row 2 Cell 4 Cell 5 Cell 6 Row 3 Cell 7 Cell 8 Cell 9.

Sample Table. Columns. Column 1 Column 2 Column 3 Row 1 Cell 1 Cell 2 Cell 3 Row 2 Cell 4 Cell 5 Cell 6 Row 3 Cell 7 Cell 8 Cell 9. Working with Tables in Microsoft Word The purpose of this document is to lead you through the steps of creating, editing and deleting tables and parts of tables. This document follows a tutorial format

More information

Chapter 3. Mastering the micropipette. Objectives

Chapter 3. Mastering the micropipette. Objectives Mastering the micropipette Welcome to the microworld! In this class, you are working with microorganisms, including yeast and bacteria, millions of which would fit into a period on this page. You will

More information

Using Excel to Graph a Linear Equation

Using Excel to Graph a Linear Equation Using Excel to Graph a Linear Equation Level: LBS 5 Goal: To become familiar with Microsoft Excel and the Chart Wizard in order to create graphs of linear equations on the computer. Learning Outcomes:

More information

MS Excel. Handout: Level 2. elearning Department. Copyright 2016 CMS e-learning Department. All Rights Reserved. Page 1 of 11

MS Excel. Handout: Level 2. elearning Department. Copyright 2016 CMS e-learning Department. All Rights Reserved. Page 1 of 11 MS Excel Handout: Level 2 elearning Department 2016 Page 1 of 11 Contents Excel Environment:... 3 To create a new blank workbook:...3 To insert text:...4 Cell addresses:...4 To save the workbook:... 5

More information

Microsoft Excel 2010 Prepared by Computing Services at the Eastman School of Music July 2010

Microsoft Excel 2010 Prepared by Computing Services at the Eastman School of Music July 2010 Microsoft Excel 2010 Prepared by Computing Services at the Eastman School of Music July 2010 Contents Microsoft Office Interface... 4 File Ribbon Tab... 5 Microsoft Office Quick Access Toolbar... 6 Appearance

More information

Creating a Game Board in Microsoft Word

Creating a Game Board in Microsoft Word Creating a Game Board in Microsoft Word 1) Open Microsoft Word. To create a game board, you will probably want to use more space on the page than is allowed by the standard margin settings. Therefore,

More information

Excel Tutorial. Bio 150B Excel Tutorial 1

Excel Tutorial. Bio 150B Excel Tutorial 1 Bio 15B Excel Tutorial 1 Excel Tutorial As part of your laboratory write-ups and reports during this semester you will be required to collect and present data in an appropriate format. To organize and

More information

UV/VIS SPECTROPHOTOMETER

UV/VIS SPECTROPHOTOMETER UV/VIS SPECTROPHOTOMETER MECASYS, Co., Ltd. What is UV/VIS? Electromagnetic Spectrum X-Rays UV VIS NIR IR Micro wave 200nm 400nm 700nm 2500nm 500 µm Type of Radiation X-Rays UV/VIS IR Micro Wave Type of

More information

How to make a line graph using Excel 2007

How to make a line graph using Excel 2007 How to make a line graph using Excel 2007 Format your data sheet Make sure you have a title and each column of data has a title. If you are entering data by hand, use time or the independent variable in

More information

Fundamentals of modern UV-visible spectroscopy. Presentation Materials

Fundamentals of modern UV-visible spectroscopy. Presentation Materials Fundamentals of modern UV-visible spectroscopy Presentation Materials The Electromagnetic Spectrum E = hν ν = c / λ 1 Electronic Transitions in Formaldehyde 2 Electronic Transitions and Spectra of Atoms

More information

Determining the Free Chlorine Content of Swimming Pool Water. HOCl H + + OCl. Evaluation copy

Determining the Free Chlorine Content of Swimming Pool Water. HOCl H + + OCl. Evaluation copy Determining the Free Chlorine Content of Swimming Pool Water Computer 33 Physicians in the nineteenth century used chlorine water as a disinfectant. Upon the discovery that certain diseases were transmitted

More information

Basic Pivot Tables. To begin your pivot table, choose Data, Pivot Table and Pivot Chart Report. 1 of 18

Basic Pivot Tables. To begin your pivot table, choose Data, Pivot Table and Pivot Chart Report. 1 of 18 Basic Pivot Tables Pivot tables summarize data in a quick and easy way. In your job, you could use pivot tables to summarize actual expenses by fund type by object or total amounts. Make sure you do not

More information

Experiment 2 Kinetics II Concentration-Time Relationships and Activation Energy

Experiment 2 Kinetics II Concentration-Time Relationships and Activation Energy 2-1 Experiment 2 Kinetics II Concentration-Time Relationships and Activation Energy Introduction: The kinetics of a decomposition reaction involving hydroxide ion and crystal violet, an organic dye used

More information

Beginning Excel. Revised 5/01

Beginning Excel. Revised 5/01 Beginning Excel Objectives: The Learner will: Become familiar with terminology used in Microsoft Excel Create a simple workbook Write a simple formula Create a simple chart Sort a simple text chart Formatting

More information

Introducing Microsoft Excel s Pivot Table Feature

Introducing Microsoft Excel s Pivot Table Feature Introducing Microsoft Excel s Pivot Table Feature Nate Moore, CPA, MBA, CMPE President Moore Solutions, Inc. If you ve ever entered a claim in a medical billing software package, you know that it takes

More information

FREE FALL. Introduction. Reference Young and Freedman, University Physics, 12 th Edition: Chapter 2, section 2.5

FREE FALL. Introduction. Reference Young and Freedman, University Physics, 12 th Edition: Chapter 2, section 2.5 Physics 161 FREE FALL Introduction This experiment is designed to study the motion of an object that is accelerated by the force of gravity. It also serves as an introduction to the data analysis capabilities

More information

Navios Quick Reference

Navios Quick Reference Navios Quick Reference Purpose: The purpose of this Quick Reference is to provide a simple step by step outline of the information needed to perform various tasks on the system. We begin with basic tasks

More information

Create a Poster Using Publisher

Create a Poster Using Publisher Contents 1. Introduction 1. Starting Publisher 2. Create a Poster Template 5. Aligning your images and text 7. Apply a background 12. Add text to your poster 14. Add pictures to your poster 17. Add graphs

More information

Summary of important mathematical operations and formulas (from first tutorial):

Summary of important mathematical operations and formulas (from first tutorial): EXCEL Intermediate Tutorial Summary of important mathematical operations and formulas (from first tutorial): Operation Key Addition + Subtraction - Multiplication * Division / Exponential ^ To enter a

More information

Your Personal Homepage

Your Personal Homepage Your Personal Homepage You can use your Personal Homepage to share information about yourself, something that interests you, or a course topic. Your classmates can view your home page from the Classlist

More information

Creating Web Pages With Dreamweaver MX 2004

Creating Web Pages With Dreamweaver MX 2004 Creating Web Pages With Dreamweaver MX 2004 1 Introduction Learning Goal: By the end of the session, participants will have an understanding of: What Dreamweaver is, and How it can be used to create basic

More information

UV Analysis of Sunscreens

UV Analysis of Sunscreens UV Analysis of Sunscreens Texas A&M University Organic Lab 238 The Electromagnetic Spectrum The UV region is the range of frequencies just higher than those for visible light UV-Vis energies correspond

More information

UV-Visible Spectroscopy

UV-Visible Spectroscopy UV-Visible Spectroscopy UV-Visible Spectroscopy What is UV-Visible Spectroscopy? Molecular spectroscopy that involves study of the interaction of Ultra violet (UV)-Visible radiation with molecules What

More information

CHEM 161: Beer s Law and Analysis of a Sports Drink

CHEM 161: Beer s Law and Analysis of a Sports Drink CHEM 161: Beer s Law and Analysis of a Sports Drink Introduction Although sunlight appears white, it contains a spectrum of colors. A rainbow actually shows this range of colors in visible light: violet,

More information

Excel Lab. Figure 1.1: Adding two numbers together in Excel

Excel Lab. Figure 1.1: Adding two numbers together in Excel Excel Lab This document serves as an introduction to Microsoft Excel. Example 1: Excel is very useful for performing arithmetic operations. Suppose we want to add 2 + 3. We begin by entering the number

More information

NNIN Nanotechnology Education

NNIN Nanotechnology Education NNIN Nanotechnology Education Student Guide Part 1: Silver Nanoparticle Synthesis and Spectroscopy Introduction: In this lab you will synthesize silver nanoparticles one of the most commonly used nanoparticles

More information

Colorimetry Extinction coefficient (ε) Lambda max (λ max ) Qualitative vs. quantitative analysis

Colorimetry Extinction coefficient (ε) Lambda max (λ max ) Qualitative vs. quantitative analysis Lab Week 2 - Spectrophotometry Purpose: Introduce students to the use of spectrophotometry for qualitative (what is it) and quantitative (how much is there of it) analysis of biological samples and molecules.

More information

INTRODUCTION TO SPECTROMETRY

INTRODUCTION TO SPECTROMETRY Experiment 11 INTRODUCTION TO SPECTROMETRY Portions adapted by Ross S. Nord and Colleagues, Chemistry Department, Eastern Michigan University from ANAL 043, written by Donald F. Clemens and Warren A. McAllister,

More information

Ultraviolet - Visible Spectroscopy (UV)

Ultraviolet - Visible Spectroscopy (UV) UV Ultraviolet - Visible Spectroscopy (UV) Introduction to Ultraviolet - Visible Spectroscopy 1 (UV) Background Theory UV Absorption of ultraviolet and visible radiation Absorption of visible and ultraviolet

More information

Molecular Biology of Life Laboratory BIOL 123. Spectrophotometer

Molecular Biology of Life Laboratory BIOL 123. Spectrophotometer Spectrophotometer A spectrophotometer is an instrument that measures the amount of light that can pass through a solution. It is apparent that less light is allowed to pass through a highly turbid or colored

More information

Spreadsheet View and Basic Statistics Concepts

Spreadsheet View and Basic Statistics Concepts Spreadsheet View and Basic Statistics Concepts GeoGebra 3.2 Workshop Handout 9 Judith and Markus Hohenwarter www.geogebra.org Table of Contents 1. Introduction to GeoGebra s Spreadsheet View 2 2. Record

More information

An Introduction to Graphing in Excel

An Introduction to Graphing in Excel An Introduction to Graphing in Excel This example uses Excel to graph Y vs X. This problem starts as follows: 1.Complete the following table and on graph paper, graph the line for the equation x 2y = Identify

More information

MCAL Spectrophotometry. Spectrophotometry

MCAL Spectrophotometry. Spectrophotometry MCAL Spectrophotometry Instruments include: Cary 50 UV-vis Spectrophotometer Eclipse Spectrofluorometer HPLC Diode Array and Fluorescence ICP-OES with CCD detection Spectrophotometry The instruments all

More information

How to create graphs with a best fit line in Excel

How to create graphs with a best fit line in Excel How to create graphs with a best fit line in Excel In this manual, we will use two examples: y = x, a linear graph; and y = x 2, a non-linear graph. The y-values were specifically chosen to be inexact

More information

PowerWorld Simulator

PowerWorld Simulator PowerWorld Simulator Quick Start Guide 2001 South First Street Champaign, Illinois 61820 +1 (217) 384.6330 support@powerworld.com http://www.powerworld.com Purpose This quick start guide is intended to

More information

Laboratory 5: Properties of Enzymes

Laboratory 5: Properties of Enzymes Laboratory 5: Properties of Enzymes Technical Objectives 1. Accurately measure and transfer solutions with pipettes 2. Use a Spectrophotometer to study enzyme action. 3. Properly graph a set of data. Knowledge

More information

Experiment Seven Determination Of The Composition Of A Multi-Component Mixture By Spectrophotometric Analysis

Experiment Seven Determination Of The Composition Of A Multi-Component Mixture By Spectrophotometric Analysis CHEM 3281 Experiment Seven Determination Of The Composition Of A Multi-Component Mixture By Spectrophotometric Analysis Objectives: 1.Solid sample handling 2.The composition of a three-component mixture