5 Port Solenoid Valve

Size: px
Start display at page:

Download "5 Port Solenoid Valve"

Transcription

1 ort Solenoid Valve Series VQ7-6/7-8 Metal Seal Rubber Seal ISO Standard Size /Size VQ7-8/Single unit.70 VQ7-8/Manifold.70 Conforms to ISO standard /I Interface conforms to ISO standard Size (VQ7-6) and Size (VQ7-8). Outstanding high speed response and long service life VQ7-6/Single unit.688 VQ7-6/Manifold.6 Enclosure I6 compliant Dusttight/Low jetproof type wide variety of manifold options Manifolds can be configured with a wide range of interface options to meet a variety of application requirements. Lighter weight [Option] Size ( position) 0.8 kg % less (Compared with previous series) Size ( position) 0.7 kg % less SJ SV J SZ VF V S0700 VQ VQ VQ VQC VQC VQZ SQ VFS VFR VQ7 Space-saving profile Installation space % reduction Installation volume 0% reduction (Compared with previous series) Choice of metal or rubber seal increases compatibility with various operating and environmental conditions. 68

2 Cylinder Speed Chart Series VQ7-6-FG-S- 0 VQ7-6-FG-S- 0 verage speed (mm/s) Use as a guide for selection. lease confirm the actual conditions with Sizing rogram. ore size Series M, C ressure 0. Ma Load factor 0% Stroke 00 mm Series CS/CS ressure 0. Ma Load factor 0% Stroke 000 mm ø0 ø0 ø6 ø80 ø00 ø ø0 ø60 ø80 ø00 erpendicular, upward actuation Horizontal actuation Series VQ7-6-FG-S- R0 verage speed (mm/s) ore size Series M, C ressure 0. Ma Load factor 0% Stroke 00 mm Series CS/CS ressure 0. Ma Load factor 0% Stroke 000 mm ø0 ø0 ø6 ø80 ø00 ø ø0 ø60 ø80 ø VQ7-6-FG-S- R It is when the cylinder is extending that is meter-out controlled by speed controller which is directly connected with cylinder, and its needle valve with being fully open. The average velocity of the cylinder is what the stroke is divided by the total stroke time. Load factor: ((Load mass x.8)/theoretical force) x 00% erpendicular, upward actuation Horizontal actuation 686

3 Cylinder Speed Chart Series VQ7-8-FG-S- 0 VQ7-8-FG-S- R0 VQ7-8-FG-S- 0 VQ7-8-FG-S- R0 Use as a guide for selection. lease confirm the actual conditions with Sizing rogram. ore size verage Series M, C Series CS/CS speed ressure 0. Ma ressure 0. Ma Load factor 0% Load factor 0% (mm/s) Stroke 00 mm Stroke 000 mm ø0 ø6 ø80 ø00 ø ø0 ø60 ø80 ø00 ø0 ø It is when the cylinder is extending that is meter-out controlled by speed controller which is directly connected with cylinder, and its needle valve with being fully open. The average velocity of the cylinder is what the stroke is divided by the total stroke time. Load factor: ((Load mass x.8)/theoretical force) x 00% Conditions erpendicular, upward actuation Horizontal actuation ase mounted Series M, C Series CS/CS ase mounted Series M, C Series CS/CS SG (Steel pipe) dia. x Length 6 x m SG (Steel pipe) dia. x Length 0 x m VQ7-6-FG-S- 0 VQ7-6-FG-S- 0 VQ7-6-FG-S- R0 VQ7-6-FG-S- R0 Speed controller Silencer SG (Steel pipe) dia. x Length Speed controller Silencer SG (Steel pipe) dia. x Length Speed controller Silencer SG (Steel pipe) dia. x Length Speed controller Silencer S000-0 N0-0 0 x m S0-0 N0-0 6 x m S000-0 N0-0 0 x m S0-0 N0-0 VQ7-8-FG-S- 0 VQ7-8-FG-S- 0 VQ7-8-FG-S- R0 VQ7-8-FG-S- R0 Speed controller Silencer SG (Steel pipe) dia. x Length Speed controller Silencer SG (Steel pipe) dia. x Length Speed controller Silencer SG (Steel pipe) dia. x Length Speed controller Silencer S000-0 N0-0 x m S0-0 N0-0 0 x m S000-0 N0-0 x m S0-0 N0-0 SJ SV J SZ VF V S0700 VQ VQ VQ VQC VQC VQZ SQ VFS VFR VQ7 687

4 ISO Standard Solenoid Valve Series VQ7-6 Size /Single Unit [Option] How to Order Valves VQ7 6 FG FG YZ FHG FJG FG FIG assage symbol () () (R)()(R) () () (R)()(R) () () (R)()(R) () () (R)()(R) () () (R)()(R) () () (R)()(R) Semi-standard Number of solenoids S D Single Double S Coil rated 6 Option Nil Z N 00 VC, 0/60Hz 00 VC, 0/60Hz VDC VDC 0 VC, 0/60Hz 0 VC, 0/60Hz For other rated voltages, please consult with. Connector Nil O SC Sub-plate port size Nil ort R is /8 Seal Nil R Without sub-plate Side ported / Side ported /8 ottom ported / ottom ported /8 Metal seal Rubber seal ilot exhaust Nil Common exhaust V Individual exhaust How to Order Sub-plate None Light/Surge voltage suppresor With indicator light CE-compliant Nil Q CE-compliant DIN terminal block (With connector) DIN terminal block (Without connector) re-wired connector T NTF VS7 0 ort size 0 Side ported / 0 Side ported /8 0 ottom ported / 0 ottom ported /8 ort (R) and (R) are /8 T NTF Specifications orting specifications Model iping (), (), (R), (R) location () port size port size VS7--0 / /8 Side VS7--0 /8 VS7--0 / /8 ottom VS7--0 /8 Weight (kg)

5 ISO Standard Solenoid Valve Series VQ7-6 Model Series VQ7-6 position position Number of positions Single Double Closed center Exhaust center Double check ressure center Metal seal Rubber seal Metal seal Rubber seal Metal seal Rubber seal Metal seal Rubber seal Metal seal Rubber seal Metal seal Rubber seal Model VQ7-6-FG-S- VQ7-6-FG-S- R VQ7-6-FG-D- VQ7-6-FG-D- R VQ7-6-FHG-D- VQ7-6-FHG-D- R VQ7-6-FJG-D- VQ7-6-FJG-D- R VQ7-6-FG-D- VQ7-6-FG-D- R VQ7-6-FIG-D- VQ7-6-FIG-D- R Flow characteristics / ( /) / / (/ E/E) C /(s bar)] b C /(s bar)] Cv [dm Cv b [dm / Note ) ased on JIS 87-8 (Value for supply pressure of 0. Ma, with light/surge voltage suppressor, when using clean air.) Response time values will change depending on pressure and air quality. Value when ON for double type. Note ) Weight without sub-plate. (Sub-plate: 0.7 kg) Symbol position single position double (Metal) () () (R)()(R) position double (Rubber) position closed center () () (R)()(R) position exhaust center () () (R)()(R) position pressure center () () (R)()(R) () () (R)()(R) () () (R)()(R) position double check () () (R)()(R) ort size Standard Specifications Valve specifications Solenoid specifications Valve construction Fluid Maximum operating pressure Min. operating pressure Single Double position Metal seal 0. Ma 0. Ma 0. Ma.0 Ma 0 or less 0.0 or less or less 0. or less 0 or less 0.8 or less 0 or less 0.8 or less 0 or less or less 0 or less 0.8 or less Rubber seal 0.0 Ma 0. Ma 0.0 Ma mbient and fluid temperature 0 to 60 C () to 60 C () Lubrication Impact/Vibration resistance Enclosure Coil rated voltage llowable voltage fluctuation Coil insulation type Not required ush type (Tool required) 0/0 m/s () I6 (Dusttight, Low jetproof) VDC, VDC, 00 VC, 0 VC, 00 VC, 0 VC, 0 VC (0/60Hz) ±0% of rated voltage Class or equivalent VDC W DC ( m) VDC W DC (8 m) 00 VC (). V ( m) 0 VC (). V (. m) ower consumption 0 VC (). V ( m) (Current) 00 VC (). V (. m) 0 VC ().6 V ( m) 0 VC ().8 V (. m) 0 VC () V ( m) ir () () Response Weight time (kg) (ms) Note ) Use dry air to prevent condensation when operating at low temperatures. Note ) Impact resistance: No malfunction occurred when it is tested with a drop tester in the axial direction and at the right angles to the main valve and armature in both energized and de-energized states every once for each condition. (Values at the initial period) Vibration resistance: No malfunction occurred in a one-sweep test between and 000 Hz. Test was performed at both energized and de-energized states in the axial direction and at the right angles to the main valve and armature. (Values at the initial period) Note ) The valve with an C coil comes with a rectifying device; therefore, there is no difference in the consumption current when it is in the inrush and holding states. 68 SJ SV J SZ VF V S0700 VQ VQ VQ VQC VQC VQZ SQ VFS VFR VQ7 C

6 ( port) ( port) Series VQ7-6 DIN Terminal Type position single : VQ7-6-FG-S single (Reverse pressure): VQ7-6-YZ-S R. R x ø6. Mounting hole x /8 (R, R) 0 6 Indicator light G / (Cable ø8 to ø0) R R.. x ø6. Mounting hole x /8 x /,/8 (,, ) ottom ported drawing (X port) Y (, port) /8 /,/8 x /8 X (E) port R, R port port /8 Y (E) port x /, /8, port position double : VQ7-6-FG-D double (Reverse pressure): VQ7-6-YZ-D position closed center : VQ7-6-FHG-D exhaust center : VQ7-6-FJG-D pressure center: VQ7-6-FIG-D ( port) ( port) ( port) ( port) R. R. Indicator light x ø6. Mounting hole R R Indicator light.. x ø6. Mounting hole (X port) G / (Cable ø8 to ø0) G / (Cable ø8 to ø0) 7 (X port) 60 /8 /, /8 x /8 X (E) port ort R, R port /8 x /8 X(E) port /, /8 R, R port port

7 ISO Standard Solenoid Valve Series VQ7-6 rewired Connector Type position single : VQ7-6-FG-S SC single (Reverse pressure): VQ7-6-YZ-S SC Cable with connector (L 00) Indicator light (X port) /8 X(E) port ( port) ( port) R R. R R. /, /8 port x ø6. Mounting hole 7 x /8 R, R port position double : VQ7-6-FG-D- SC double (Reverse pressure): VQ7-6-YZ-D- SC Cable with connector (L 00) Indicator light ( port) ( port) x ø6. Mounting hole /8 Y(E) port Y R R. R ottom ported drawing (, port) x /, /8, port ( port) ( port). R. x ø6. Mounting hole x /8 x /8 (R, R) 0 6 x /, /8 (,, ) position closed center : VQ7-6-FHG-D- SC exhaust center : VQ7-6-FJG-D- SC pressure center: VQ7-6-FIG-D- SC Cable with connector (L 00) Indicator light x ø6. Mounting hole SJ SV J SZ VF V S0700 VQ VQ VQ VQC VQC VQZ SQ VFS VFR VQ7 (X port) /8 /, /8 x /8 X(E) port port R, R port 7 (X port) /8 X(E) port /, /8 ort x /8 R, R port 7 6

8 Series VQ7-6 Construction DIN Terminal Type Metal seal type VQ7-6-FG-S- t r w Rubber seal type VQ7-6-FG-S- R t r w q VQ7-6-FG-D- t r w q VQ7-6-FG-D- R t r w VQ7-6- q FHG FJG FIG t r w -D- VQ7-6- q FHG FJG FIG -D- R t r w q VQ7-6-FG-D- t q r w q e Replacement arts (For valve) No. Description VQ7-6-FG-S- FHG VQ7-6-FG-D- VQ7-6- FJG FIG FHG -D- VQ7-6-FG-D- VQ7-6-FG-S- R VQ7-6-FG-D- R VQ7-6- FJG FIG-D- R VQ ilot valve assembly () () VQZ0Q- (: VDC, 6: VDC, : For C () ) Double check spacer VV7-FG ilot valve cover VQ DIN terminal UKL-S Note ) When the voltage is the same, the replacement of pilot valve assembly is possible. Note ) Since the substrate circuit in the valve is different, voltage cannot be changed with the pilot valve assembly. Note ) The pilot valve for 00 to 0 VC is common. 6

9 VV7 6 (), () port connection 0R 0R 0L 0L 0Y 0Y C6R C8R C0R C6L C8L C0L Stations station 0 0 stations Note) When equipped with control unit, or stations are used for mounting. / (R side) /8 (R side) / (L side) /8 (L side) / (ottom side) /8 (ottom side) One-touch fitting ø6 (R side) One-touch fitting ø8 (R side) One-touch fitting ø0 (R side) One-touch fitting ø6 (L side) One-touch fitting ø8 (L side) One-touch fitting ø0 (L side) Mixed Manifold Series VV7 Series VQ7-6 0R Note) When ports are mixed, indicate piping specifications by means of the manifold specification sheet. Manifold Specifications Manifold block size ISO size pplicable solenoid valve Series VQ7-6 ISO size T NTF Note) With One-touch fittings: Nil orting specifications (), () port ort location ort size Right, Left ottom / /8 C6 (ø6) C8 (ø8) C0 (ø0) / /8 How to Order Manifold (), (R) (R) port size / /8 C (ø) Note) When equipped with control unit, or stations are used for mounting. 0D Silencer box Nil S None With (), (R), (R) port connection 0D 0U 0 0D 0U 0 CD CU C Note) The silencer box is mounted on the end plate located on the side (D, U, ) that is selected in (), (R), (R) port connection. / (D side) / (U side) / (oth sides) /8 (D side) /8 (U side) /8 (oth sides) One-touch fitting ø (D side) One-touch fitting ø (U side) One-touch fitting ø (oth sides) Mixed CE-compliant Nil Q CE-compliant ir release valve coil rating Nil 6 Note) When ports are mixed, indicate piping specifications by means of the manifold specification sheet. Control unit type (See pages 700 and 70 for details.) Symbol Control equipment Nil M M C E ir filter with auto-drain ir filter with manual drain Regulator ir release valve ressure switch lanking plate (ir release valve) lanking plate (Filter, Regulator) lanking plate (ressure switch) Number of manifold blocks required for mounting (stations) Stations Note) Max. 0 stations Weight (kg) 0.n + 0. (n: Stations) [Option] None 00 VC, 0/60 Hz 00 VC, 0/60 Hz VDC VDC 0 VC, 0/60 Hz 0 VC, 0/60 Hz For other rated voltages, please consult with. T NTF Note) With One-touch fittings: Nil 6 SJ SV J SZ VF V S0700 VQ VQ VQ VQC VQC VQZ SQ VFS VFR VQ7

10 Series VQ7-6 DIN Terminal Type VV U side n x /, / U side R. Indicator light R. L L L L 0 =. =. L side D side R side (n x /8) 8 n x /, /8 (, port) R side D side L side (Single) (Double) ( position) (Single) (Double) ( position) ottom ported drawing 6.. x /8 (ilot pressure EXH port) R R R 6 x /, /8 (, R port) 6 L Dimension L L n: Stations Formula L = n + 6 L = n

11 ISO Standard Solenoid Valve Series VQ7-6 rewired Connector Type VV U side Indicator light R. 0 =. SJ SV J L L SZ VF V S0700 VQ L side D side (Single) (Double) ( position) R side (n x /8) n x /, /8 (, port) VQ VQ VQC VQC VQZ SQ VFS x /8 (ilot pressure EXH port) R R R 6 VFR VQ x /, /8 (, R port) L Dimension L 07 0 L n: Stations Formula L = n + 6 L = n

12 0 Series VQ7-6 Manifold Option arts lanking plate assembly XT0- It is used by attaching on the manifold block for being prepared for removing a valve for maintenance reasons or planning to mount a spare valve, etc. lock plate (For SU/EXH passages) XT0- When two or more different high pressures are supplied to one manifold, block plates are installed between stations having different pressures. lso, in cases such as when valve exhaust effects other stations in a circuit, block plates are used for exhaust at stations where the exhaust is to be separated ccessory Description art no. olt XT00- XT SU passage blocked EXH passage blocked SU passage EXH blocked Individual SU spacer 0 VV7-- 0 C0 T NTF Note) It is not applicable to One-touch fittings. y mounting individual SU spacers on a manifold block, it is possible to provide individual supply ports for each valve. ' lock plate (For pilot EXH passage) Z0- When a valve s pilot valve exhaust effects other valves in a circuit, block plates are used between stations where the pilot exhaust passages are to be separated. 8.6 ø ccessory Description art no. olt XT00- XT6--6 Individual EXH spacer 0 VV7-R- 0 C T NTF y mounting individual EXH spacers on a manifold block, exhaust ports can be provided individually for each valve. (, common EXH type) Note) It is not applicable to One-touch fittings. Throttle valve spacer XT0- throttle valve spacer is mounted on a manifold block to control cylinder speed by throttling exhaust air flow. 8 8 ' 00 8 ccessory Description art no. olt XT00- XT6--6 ccessory Description art no. olt XT00- XT6-- 66

13 ISO Standard Solenoid Valve Series VQ7-6 Reverse pressure spacer XT0-- T NTF R, R individual EXH spacer VV7-R-0 00 T NTF 00 With reverse pressure control manifold specifications, when pressure is changed individually on one side (ex. high speed cylinder return), pressure can be supplied individually to the R side by mounting a reverse pressure spacer. {ort (R) is individual and (R) is common.} ' ccessory Description olt art no. XT00- XT6--6 art no. XT00- XT6--6 y mounting an individual EXH spacer on a manifold block, individual exhaust is possible from both R and R. { (R) and (R) are individual ports.} ccessory Description olt Main EXH back pressure check plate XT ' In cases where back pressure effects actuator operation due to simultaneous operation of manifold valves, etc., this effect can be eliminated by installing a plate between the manifold block and the valve from which back pressure is to be prevented. ' Residual pressure release valve spacer VV7-R- This is used by mounting on a manifold block in order to exhaust the residual pressure trapped inside of a cylinder, etc., during an intermediate stop with a position closed center or perfect type valve. Residual pressure at ports and is exhausted individually to the outside by manual operation. 8 T NTF 6 / / T NTF / 0 ccessory Description olt art no. XT00- XT6--6 art no. XT00- XT6--6 This is used by mounting on a manifold block in order to stop the inlet side supply pressure in an individual supply spacer, while at the same time exhausting the residual pressure are performed by pressing the manual override, which can be locked by turning it. ccessory Description olt dapter plate for locked-up cylinder XT0-6 8 ' ' When using a locked-up cylinder with valves for control, this spacer can be used by mounting on a manifold block. It consists of a circuit equipped with a function to prevent lurching during release. SJ SV J SZ VF V Individual SU spacer with residual pressure release valve S VV7-R- 0 VQ VQ VQ VQC VQC VQZ SQ VFS VFR VQ7 8 o 6 8 ccessory Description olt art no. XT00- XT The locking cylinder is indicated by s symbol. ccessory Description art no. olt XT00- XT

14 Series VQ7-6 Manifold Option arts Silencer box VV7- - -S This can be provided as a unit on the end plate to reduce manifold exhaust noise and piping labor. ilot EXH silencer N0-0 This is used by mounting on the pilot exhaust port in order to reduce manifold and single type pilot exhaust noise, and to prevent the entry of dust. Release valve spacer XT0-7 /8 /8 T NTF /8 Combination of VQ7-6-FG-S (Single) and release valve spacer can be used as air release valve. Note) Mounting on position double and position valves is not possible ' ccessory Description art no. XT00- olt XT6--7 Residual pressure release valve spacer Z0-8 Z0-8 ilot type Internal pilot External pilot t the same time as pilot pressure is released, residual pressure between the cylinder and valve is released. There are two pilot types: internal pilot and external pilot types. <Switching valve side> R.... R Z0-8 0 R E 8 R E 8 R.... R EXH. <Manifold side> <Switching valve side> R.... R R.... R EXH. <Manifold side> E EXH. EXH. Specifications Model Switching signal type (ilot type) pplicable solenoid valve pplicable sub-plate Max. operating pressure Min. operating pressure mbient and fluid temperature Lubrication ccessory Description art no. XT00- olt XT6--6 Z0-8 Internal pilot Z0-8 External pilot VQ7-6 ISO standard size.0 Ma 0. Ma (ressure generated when the valve element is switched to the stopping side.) to 60 C Non-lube (Use turbine oil Class (ISO VG), if lubricated.) 68

15 ISO Standard Solenoid Valve Series VQ7-6 Double check spacer VV7-FG Double check spacer with residual pressure release valve VV7-FGR y combining a position exhaust center valve with a double check spacer, an intermediate stopping position of a cylinder can be held for an extended period. It can also be used for drop prevention at the cylinder stroke end when releasing residual supply pressure, by combining it with a position single or double valve. 7 ccessory Description olt Specifications art no. XT00- XT6--8 Double check spacer part no. pplicable solenoid or air operated valve One solenoid energized (One pilot pressurized) Leakage (cm /min (NR)) Interface regulator R oth solenoids unenergized (oth pilots unpressurized) VV7-FG Series VQ7-6, VS7-6 R R R R R R Interface regulators can be placed on top of the manifold block to reduce the pressure of each of the valves This is a double check spacer equipped with a residual pressure release function, to release residual pressure inside a cylinder during maintenance or adjustment, etc. 8 ccessory Description olt Caution art no. XT00- XT6--8 Since extended cylinder stops are not possible if there are leaks from piping between the valve and cylinder or from fittings, etc., check for leakage using a neutral liquid detergent. Since One-touch fittings allow slight air leakage, screw piping is recommended when stopping the cylinder in the middle for a long time. Combination of position, closed center and pressure center valves is not possible. Set the load weight so that the cylinder side pressure is less than two times the supply side pressure. When using the residual pressure release function, confirm the action of actuators, etc., and operate after providing for safety measures. e aware that if the exhaust side of perfect spacer is restricted excessively, the intermediate stopping accuracy will decrease and will lead to improper intermediate stops. 8 Exhaust 0 SJ SV J SZ VF V S0700 VQ VQ VQ VQC VQC VQZ SQ VFS VFR VQ7 0 ccessory Description olt art No. reduced pressure reduced pressure reduced pressure art no. XT00- XT6--8 R0-00- R0-00- R0-00- Caution Regulating port Regulating port Regulating port When combining a pressure center valve and interface regulator with reduced pressure at ports and, use model R0-. When combining a reverse pressure valve and interface regulator, use model R0-. Further, it cannot be used with reduced pressure at port. When combining a double check valve and an interface regulator, use a manifold or sub-plate as a basis, and stack them in the following order; the perfect spacer the interface regulator the valve. When a closed center valve is combined with the interface regulator s, port regulation, note that it cannot be used for intermediate stops of a cylinder because there is leakage from relief port on the regulator. 6

16 Series VQ7-6 Control Unit Control equipment (filters, regulators, pressure switches, air release valves) has been made into standardized units which can be mounted on manifolds without any modifications. Control Unit Specifications ir filter (With auto-drain/with manual drain) Filtration degree µm Regulator Set pressure (Outlet pressure) 0.0 to 0.8 Ma ressure switch ressure adjustment range 0. to 0.7 Ma Contact ab Rated current (Induction load) VC, 0 VC ir release valve (Single only) Operating pressure range 0. to.0 Ma Options lanking plate Release valve adapter plate ressure switch XT0- (For manifold) XT0-8 (For release valve adapter plate) M (For control equipment/filter regulator) M- (For pressure switch) XT0-7 IS00-X0 Manifold specifications example XT0- VQ7-6-FHG-D VQ7-6-FG-D VQ7-6-FG-S ir release valve ressure switch ' ir filter regulator Control unit o" Control Unit Type Ordering symbol Control equipment ir filter with auto-drain ir filter with manual drain Regulator ir release valve ressure switch lanking plate (ir release valve) lanking plate (Filter, Regulator) lanking plate (ressure switch) Number of manifold blocks required for mounting (stations) Use of Control Unit Nil M M C E stations stations stations stations stations stations stations station <Construction and piping >. The supply pressure (o) passes through the regulator with filter q and is adjusted to the prescribed pressure. Next, it goes through the release valve w (downstream residual pressure switching function used as normally ON) and is supplied to the manifold base side ().. When the release valve w is OFF, the supply pressure from port o is blocked, and the air which was being supplied to the manifold side port passes through the release valve w and is discharged from port R.. The pressure switch is piped into the outlet side of the release valve w. (It operates when the release valve w is energized.) lso, since there is an internal voltage drop of V, it may not be possible to confirm the OFF and ON states with a tester, etc. Caution In the case of air filters with auto-drain or manual drain, mount so that the air filter is at the bottom. 700

17 ISO Standard Solenoid Valve Series VQ7-6 Manifold with control unit L side ( position) (Double) 0. (Single) U side R. R side n x /8 6 6 n x /, /8 (, port) 0 =. SJ SV J SZ Indicator light L L VF V Release valve L S0700 VQ 8 VQ Control unit ressure switch (. for M) VQ VQC VQC VQZ D side 8 ø. Drain port : / SQ VFS VFR VQ7 /8 Supply port x /8 (ilot pressure EXH port) n: Stations Formula L L = n + 6 L L = n + 76 L L = n + (.) (8.) (0.) (.) (87.) (0.) (7.) (6.) (.) (60.) (6.) L Dimension R R R x /, /8 (R, R port) 6 8 L dimensions inside ( ) are for M. 8 70

18 R E R R R R R R Series VQ7-6 Manifold Option arts Interface regulator R0-00- Residual pressure release valve spacer Z0-8 Interface regulator R (7) 0 (77). (6.) 0. (77.) Residual pressure release valve spacer (Z0-8) E R (67) 6 (7). (67.) 8. (.) Dimensions inside ( ) are for sub-plate. Dimensions inside ( ) are for sub-plate. Throttle valve spacer XT0- Silencer box XT0-60 Throttle valve spacer (XT0-) S L O W 6 (7) (6). (6.) 7. (.) R R R R R R Dimensions inside ( ) are for sub-plate. Spare parts Description art no. Element XT

19 R R R R R R ISO Standard Solenoid Valve Series VQ7-6 Individual SU spacer VV7-- Individual EXH spacer VV7-R- R, R individual EXH spacer VV7-R-0 Reverse pressure spacer XT0-- n x /, / Individual SU spacer: VV7-- x /, /8, C0 Individual EXH spacer: VV7-R- x /, /8, C R, R individual EXH spacer: VV7-R-0 x /8 Reverse pressure spacer XT0-- Rc /8 (Right side only) Main EXH back pressure check plate XT0-7 Main EXH back pressure check plate (TX0-7) R R R R R R Double check spacer VV7-FG Double check spacer with residual pressure release valve VV7-FGR Dimensions inside ( ) are for sub-plate. Dimensions inside ( ) are for sub-plate. 6 (7) 0 (77) 6 (7) (67). (6.) 0. (77.) Double check spacer (VV7-FG) Double check spacer with residual pressure release valve (VV7-FGR) Residual pressure release valve spacer VV7-R- Individual SU spacer with residual pressure release valve VV7-R-. (67.) 8. (.) Residual pressure exhaust valve spacer (VV7-R-) Individual SU spacer with residual pressure release valve (VV7-R- ) SJ SV J SZ VF V S0700 VQ VQ VQ VQC VQC VQZ SQ VFS VFR VQ7 70

20 ISO Standard Solenoid Valve Series VQ7-8 Size /Single Unit [Option] How to Order Valves VQ7 8 FG FG YZ FHG FJG assage symbol () () (R)()(R) () () (R)()(R) () () (R)()(R) () () S Connector Nil O SC Sub-plate port size Nil Without sub-plate 0 Side ported /8 0 Side ported / 06D Side ported / 0 ottom ported /8 0 ottom ported / 06 ottom ported / Seal Nil Metal seal R Rubber seal CE-compliant Nil Q CE-compliant DIN terminal block (With connector) DIN terminal block (Without connector) re-wired connector T NTF FG FIG (R)()(R) () () (R)()(R) () () (R)()(R) Semi-standard Number of solenoids S D Single Double Coil rated 6 Option Nil Z N 00 VC, 0/60Hz 00 VC, 0/60Hz VDC VDC 0 VC, 0/60Hz 0 VC, 0/60Hz For other rated voltages, please consult with. ilot exhaust Nil Common exhaust V Individual exhaust None Light/Surge voltage suppressor With indicator light How to Order Sub-plate 70 VS7 0 ort size 0 Side ported /8 0 Side ported / 06D Side ported / 0 ottom ported /8 0 ottom ported / 06 ottom ported / T NTF Specifications Model VS7--0 VS7--0 VS7--06 VS7--0 VS7--0 VS7--06 orting specifications iping location Side ottom ort size /8 / / /8 / / Weight (kg)

21 ISO Standard Solenoid Valve Series VQ7-8 Model Series VQ7-8 position position Number of positions Single Double Closed center Exhaust center Double check ressure center Metal seal Rubber seal Metal seal Rubber seal Metal seal Rubber seal Metal seal Rubber seal Metal seal Rubber seal Metal seal Rubber seal Model ort size VQ7-8-FG-S- VQ7-8-FG-S- R VQ7-8-FG-D- VQ7-8-FG-D- R VQ7-8-FHG-D- VQ7-8-FHG-D- R /8 VQ7-8-FJG-D- VQ7-8-FJG-D- R VQ7-8-FG-D- VQ7-8-FG-D- R VQ7-8-FIG-D- VQ7-8-FIG-D- R Valve construction Fluid Maximum operating pressure Min. operating pressure Flow characteristics / ( /) / / (/ E/E) C /(s bar)] b C [dm/(s bar)] Cv [dm Cv b Single Double position Metal seal 0. Ma 0. Ma 0. Ma.0 Ma Rubber seal 0.0 Ma 0. Ma 0.0 Ma mbient and fluid temperature 0 to 60 C () to 60 C () Lubrication Impact/Vibration resistance Enclosure Coil rated voltage llowable voltage fluctuation Coil insulation type Not required ush type (Tool required) 0/0 m/s () I6 (Dusttight, Low jetproof) VDC, VDC, 00 VC, 0 VC, 00 VC, 0 VC, 0 VC (0/60Hz) ±0% of rated voltage Class or equivalent VDC WDC ( m) VDC WDC (8 m) 00 VC (). V ( m) 0 VC (). V (. m) ower consumption (Current) 0 VC (). V ( m) 00 VC (). V (. m) 0 VC ().6 V ( m) 0 VC ().8 V (. m) 0 VC () V ( m) ir () () Response Weight time (kg) (ms) 0 or less 0.6 or less or less or less or less or less or less or less 60 or less.8 60 or less or less or less Note ) ased on JIS 87-8 (Value for supply pressure of 0. Ma, with light/surge voltage suppressor, when using clean air.) Response time values will change depending on pressure and air quality. Value when ON for double type. Note ) Weight without sub-plate. (Sub-plate: /8, /: 0.68 kg, /:. kg) Symbol position single position double (Metal) () () (R)()(R) position double (Rubber) position closed center () () (R)()(R) position exhaust center () () (R)()(R) position pressure center () () (R)()(R) () () (R)()(R) () () (R)()(R) position double check () () (R)()(R) Standard Specifications Valve specifications Solenoid specifications Note ) Use dry air to prevent condensation when operating at low temperatures. Note ) Impact resistance: No malfunction occurred when it is tested with a drop tester in the axial direction and at the right angles to the main valve and armature in both energized and de-energized states every once for each condition. (Values at the initial period) Vibration resistance: No malfunction occurred in a one-sweep test between and 000 Hz. Test was performed at both energized and de-energized states in the axial direction and at the right angles to the main valve and armature. (Values at the initial period) Note ) Since C coil specifications include a rectifying device, there is no difference in power consumption between inrush and holding. 70 SJ SV J SZ VF V S0700 VQ VQ VQ VQC VQC VQZ SQ VFS VFR VQ7 C

22 0(0) 0(0) Y Series VQ7-8 DIN Terminal Type position single : VQ7-8-FG-S single (Reverse pressure): VQ7-8-YZ-S (6) 6(6) 6(0)( port) 6(0)( port) ottom ported drawing 8. (6) Note ) (6) Note ) () () R R x ø7. Mounting hole R R Indicator light (6) Note ) (6) Note ) G / (Cable ø8 to ø0) 0 6(7) 7(86) x ø7. Mounting hole (0) 8 8 (0) (8) (8) () 0 (6) () 6 6 () 6(7) 7(86) x /8 x /8, /, / (,,, R, R) (6) () 08.(6.) 0(8) 8(8) (7) (0) /8 X(E) port /8 Y(E) port (0) (, port) 8(8) x /8, /, / R, R port 0 (7) x /8, /, /, port /8, /, / ( ): / port Note ) For /, the mounting hole pitch differs between the side ported type and the bottom ported type. position double : VQ7-8-FG-D double (Reverse pressure): VQ7-8-YZ-D (6) 6(6) 6(0)( port) 6(0)( port) position closed center : VQ7-8-FHG-D exhaust center : VQ7-8-FJG-D pressure center: VQ7-8-FIG-D (6) 6(6) 6(0)( port) 6(0)( port) 7(86) 6(7) 0 8 7(86) 6(7) 0 8 G / (Cable ø8 to ø0) R R (6) (6) Indicator light R R x ø6. (6) (6) Mounting hole G / (Cable ø8 to ø0) Indicator light x ø6. Mounting hole (6) () (6.) 0(8) 8(8) (7) (0) /8 X(E) port ( ): / x /8, /, / R, R port 0(0) 0(0) /8, /, / port (6) () 08.(6.) 0(8) 8(8) (7) (0) /8 X(E) port x /8, /, / 0(0) 0(0) R, R port /8, /, / port ( ): / Dimensions inside are for rubber seals.

23 ISO Standard Solenoid Valve Series VQ7-8 rewired Connector Type position single : VQ7-8-FG-S- SC single (Reverse pressure): VQ7-8-YZ-S- SC ottom ported drawing Cable with connector (L 00) Indicator light 8() /8 X(E) port R (6) 6(6) 6(0)( port) 6(0)( port) R R (6) Note ) (6) Note ) 0(0) 0(0) (6) 6(6) 6(0)( port) 6(0)( port) R (6) (6) 0 6(7) 7(86) x ø7. Mounting hole (0) (7) 0(8) x /8, /, / R, R port /8, /, / port position single : VQ7-8-FG-D- SC single (Reverse pressure): VQ7-8-YZ-D- SC Cable with connector (L 00) Indicator light 8 0 x ø7. Mounting hole 6(7) 7(86) 08.(6.) Y 0 (7) 8. (6) Note ) (6) Note ) () () R (0) 8 8 (0) (8) (8) (0) (, port) 8(8) /8 Y(E) port R x /8, /, /, port ( ): / (6) 6(6) 6(0)( port) 6(0)( port) x ø7. Mounting hole () 0 (6) 6 () () 6 6(7) 7(86) x /8 x /8, /, / (,,, R, R) Note ) For /, the mounting hole pitch differs between the side ported type and the bottom ported type. position closed center : VQ7-8-FHG-D- SC exhaust center : VQ7-8-FJG-D- SC pressure center : VQ7-8-FIG-D- SC Cable with connector (L 00) Indicator light 8 0 R R (6) (6) x ø7. Mounting hole 6(7) 7(86) SJ SV J SZ VF V S0700 VQ VQ VQ VQC VQC VQZ SQ VFS VFR VQ7 8() /8 X(E) port 0(0) 0(0) (0) (7) 0(8) x /8, /, / R, R port /8, /, / port 08.(6.) 8() /8 X(E) port 0(0) 0(0) x /8, /, / R, R port /8, /, / port (0) (7) 0(8) 08.(6.) ( ): / ( ): / Dimensions inside are for rubber seals. 707

24 Series VQ7-8 Construction DIN Terminal Type Metal seal VQ7-8-FG-S- t e w Rubber seal type VQ7-8-FG-S- R t e w q VQ7-8-FG-D- t e w q VQ7-8-FG-D- R t e w q VQ7-8- FHG FJG FIG t e w -D- VQ7-8- q FHG FJG FIG t e w -D- R q VQ7-8-FG-D- t q e w q r Replacement arts (For valve) Number Description VQ7-8-FG-S- FHG VQ7-8-FG-D- VQ7-8- FJG FHG -D- VQ7-8-FG-D- VQ7-8-FG-S- R VQ7-8-FG-D- R VQ7-8- -D- R ilot valve assembly () () ilot valve cover Double check spacer DIN terminal FIG VQ VQZ0Q- (: VDC, 6: VDC, : For C () ) VQ VV7-FG UKL-S Note ) When the voltage is the same, the replacement of pilot valve assembly is possible. Note ) Since the substrate circuit in the valve is different, voltage cannot be changed with the pilot valve assembly. Note ) The pilot valve for 00 to 0 VC is common. FIG 708

25 VV7 6 (), () port connection 0R 0R 0L 0L 0Y 0Y Stations station 0 0 stations /8 (R side) / (R side) /8 (L side) / (L side) /8 (ottom side) / (ottom side) Mixed 0R Note) When ports are mixed, indicate piping specifications by means of the manifold specification sheet. Manifold Specifications Manifold block size ISO size pplicable solenoid valve Series VQ7-8 ISO size Manifold Series VV7 Series VQ7-8 T NTF orting specifications (), () port size /8 / (), (R) (R) port size / / How to Order Manifold ir release valve Nil E Stations Max. 0 stations 0D (), (R), (R) port connection 0D 0U 0 06D 06U 06 / (D side) / (U side) / (oth sides) / (D side) / (U side) / (oth sides) None With air release valve Weight (kg) 0.6n (n: Stations) T NTF CE-compliant Nil Q CE-compliant ir release valve coil rating Silencer box Nil S Nil 6 None With None 00 VC, 0/60 Hz 00 VC, 0/60 Hz VDC VDC 0 VC, 0/60 Hz 0 VC, 0/60 Hz [Option] For other rated voltages, please consult with. Note) The silencer box is mounted on the end plate located on the side (D, U, ) that is selected in (), (R), (R) port connection. SJ SV J SZ VF V S0700 VQ VQ VQ VQC VQC VQZ SQ VFS VFR VQ7 70

26 Series VQ7-8 DIN Terminal Type VV U side R. Indicator light 8 x /8, R, R port for / only =6 60 (7) n x /8,/ = 6 60 (7) R. 8 U side L L L L L side D side 8. (Single) 7. (Double) ( position) R side (n x /8) () n x /8, / R side D side 8. (Single) 7. (Double) ( position) L side ottom ported drawing x /8 (ilot pressure EXH port) 6 x /, / R () () R 0 8 (7) 0 (.) ( ): / Dimensions inside are for rubber seals. L Dimension, R, R port L n L / L L / L Note) L dimension of S type with a port size of / is the same as of S type with a port size of / Formula n: Stations L = 6n + 6 L = 6n + 80 n: Stations L = 6n + 0 L = 6n

27 ISO Standard Solenoid Valve Series VQ7-8 re-wired Connector Type VV7 - - Indicator light 8 U side R. 8 L L x /8, R, R port for / = 6 60 (7) SJ SV J SZ VF V n x /8, / S0700 VQ VQ L side D side 8. (Single) 7. (Double) ( position) R side (n x /8) () VQ VQC VQC VQZ SQ VFS x /8 (ilot pressure EXH port) 6 x /, / R () () R 0 8 (7) 0 (.) ( ): / Dimensions inside are for rubber seals. VFR VQ7 L Dimension, R, R port L n L / L L / L Note) L dimension of S type with a port size of / is the same as of S type with a port size of / Formula n: Stations L = 6n + 6 L = 6n + 80 n: Stations L = 6n + 0 L = 6n

28 Series VQ7-8 Manifold Option arts lanking plate assembly XT- It is used by attaching on the manifold block for being prepared for removing a valve for maintenance reasons or planning to mount a spare valve, etc. lock plate (For SU/EXH passages) XT-- (For SU) XT-- (For EXH) When two or more different high pressures are supplied to one manifold, block plates are installed between stations having different pressures. lso, in cases such as when valve exhaust effects other stations in a circuit, block plates are used for exhaust at stations where the exhaust is to be separated. 8 0 For SU ø7 ø SU passage blocked EXH passage blocked SU passage EXH blocked ccessory Description art no. XT0- olt XT6-- For EXH Individual SU spacer 0 VV7-- 0 T NTF y mounting individual SU spacers on a manifold block, it is possible to provide individual supply ports for each valve. lock plate (For pilot EXH passage) Z- When a valve s pilot valve exhaust effects other valves in a circuit, block plates are used between stations where the pilot exhaust passages are to be separated. ' 6. ccessory Description art no. XT0- olt XT6-- Individual EXH spacer VV7-R- 0 0 T NTF y mounting individual EXH spacers on a manifold block, exhaust ports can be provided individually for each valve. (, common exhaust type) ' Throttle valve spacer XT0- throttle valve spacer is mounted on a manifold block to control cylinder speed by throttling exhaust air flow. 0 8 ccessory Description art no. XT0- olt XT6-- ccessory Description art no. XT0- olt XT6-- 7

29 ISO Standard Solenoid Valve Series VQ7-8 Reverse pressure spacer XT-- With reverse pressure control manifold specifications, when pressure is changed individually on one side (ex. high speed cylinder return), pressure can be supplied individually to the R side by mounting a reverse pressure spacer. {ort (R) is individual and (R) is common.} R/R individual EXH spacer VV7-R-0 T NTF Conversion adapter plate VV7-V- T NTF ort size /8 / ccessory Description art no. XT0- olt XT6-- y mounting an individual EXH spacer on a manifold block, individual exhaust is possible from both R and R. { (R) and (R) are individual ports.} ' ' ' ccessory Description art no. XT0- olt XT6-- Main EXH back pressure check plate XT- In cases where back pressure effects actuator operation due to simultaneous operation of manifold valves, etc., this effect can be eliminated by installing a plate between the manifold block and the valve from which back pressure is to be prevented. 8 /8 /8 T NTF /8 ccessory Description art no. XT0- olt XT6-- dapter plate for locked-up cylinder XT When using a locked-up cylinder with valves for control, this spacer can be used by mounting on a manifold block. It consists of a circuit equipped with a function to prevent lurching during release. 06 o 0 ccessory Description olt art no. XT0- XT6-- The locking cylinder is indicated by s symbol. 8 SJ SV J SZ VF V S0700 VQ VQ VQ VQC VQC VQZ SQ VFS VFR VQ7 This conversion adapter plate allows a VQ7-6 (size ) valve to be mounted on a VQ7-8 manifold base. (V type) 00 When a conversion adapter plate is mounted, remove the adapter plate on the manifold block and assemble in the order of gasket and conversion adapter plate. ccessory Description olt art no. XT- M6 x 0 (With switch) M x 0 (With switch) 7

30 Series VQ7-8 Manifold Option arts Release valve spacer XT-7 (/8) (/8) T NTF(/8) Combination of VQ7-8-FG-S (Single) and release valve spacer can be used as air release valve. Note) Mounting on position double and position valves is not possible ' ccessory Description art no. XT0- olt XT6-- Residual pressure release valve spacer Z- ilot type Internal pilot External pilot t the same time as pilot pressure is released, residual pressure between the cylinder and valve is released. There are two pilot types: internal pilot and external pilot types. Z- <Switching valve side> R.... R Z- 7 R.... R EXH. <Manifold side> <Switching valve side> R.... R EXH. ccessory Description art no. XT0- olt XT6-- Specifications Model Switching signal type (ilot type) Z- Internal pilot Z- External pilot pplicable solenoid valve pplicable sub-plate Max. operating pressure VQ7-8 ISO standard size.0 Ma 0. Ma Min. operating pressure (ressure generated when the valve element is switched to the stopping side.) R.... R EXH. <Manifold side> E EXH. mbient and fluid temperature Lubrication to 60 C Non-lube (Use turbine oil Class (ISO VG), if lubricated.) 7

31 ISO Standard Solenoid Valve Series VQ7-8 Manifold Option arts Double check spacer VV7-FG y combining a position exhaust center valve with a double check spacer, an intermediate stopping position of a cylinder can be held for an extended period. It can also be used for drop prevention at the cylinder stroke end when releasing residual supply pressure, by combining it with a position single or double valve. 8 Interface regulator R Caution Since extended cylinder stops are not possible if there are leaks from piping between the valve and cylinder or from fittings, etc., check for leakage using a neutral liquid detergent. Since One-touch fittings allow slight air leakage, screw piping is recommended when stopping the cylinder in the middle for a long time. Combination of position, closed center and pressure center valves is not possible. Set the load weight so that the cylinder side pressure is less than two times the supply side pressure. When using the residual pressure release function, confirm the action of actuators, etc., and operate after providing for safety measures. e aware that if the exhaust side of perfect spacer is restricted excessively, the intermediate stopping accuracy will decrease and will lead to improper intermediate stops. Silencer box VV7- - -S This can be provided as a unit on the end plate to reduce manifold exhaust noise and piping labor. Interface regulators can be placed on top of the manifold block to reduce the pressure of each of the valves. SJ SV J SZ VF V S0700 VQ VQ VQ VQC VQC VQZ SQ VFS VFR VQ7 8 ccessory Description art no. olt XT0- XT6--6 art No. reduced pressure R0-00- reduced pressure R0-00- reduced pressure R0-00- Caution Regulating port Regulating port Regulating port When combining a pressure center valve and interface regulator with reduced pressure at ports and, use model R0-. When combining a reverse pressure valve and interface regulator, use model R0-. Further, it cannot be used with reduced pressure at port. When combining a double check valve and an interface regulator, use a manifold or sub-plate as a basis, and stack them in the following order; the perfect spacer the interface regulator the valve. When a closed center valve is combined with the interface regulator s, port regulation, note that it cannot be used for intermediate stops of a cylinder because there is leakage from relief port on the regulator. 7

32 RIE S L O W R R E E E E E E E R E R R E R E E E E E E E R R Series VQ7-8 Manifold Option arts Interface regulator R0-00- Main EXH back pressure check plate XT- Interface regulator R Main EXH back pressure check plate (XT-) 80. (0) 6. (8) 0 0. (80). () (0) 6 0 (0.). (00.). (.). 80. (0) 6. (0) 8 6. (6) 0 8. (08) Dimensions inside ( ) are for sub-plate aperture /8 and /. Dimensions inside are for sub-plate aperture /. Throttle valve spacer XT0- Double check spacer VV7-FG Throttle valve spacer (XT0-) Double check spacer VV7-FG Dimensions inside ( ) are for sub-plate aperture /8 and /. Dimensions inside are for sub-plate aperture /. Dimensions inside ( ) are for sub-plate aperture /8 and /. Dimensions inside are for sub-plate aperture /. 76

33 ISO Standard Solenoid Valve Series VQ7-8 Manifold Option arts Individual EXH spacer VV7-R-0, 0 Individual SU spacer VV7--0, 0 R/R individual EXH spacer VV7-R-0 Silencer box XT-6 Reverse pressure spacer XT-- SJ R E E R E E E SV J Individual EXH spacer: VV7-R- x /8, / Individual SU spacer: VV7-- x /8, / R, R individual EXH spacer: VV7-R-0 x / Reverse pressure spacer: X-- x /8, / E E 78 Spare parts Description art no. Element XT-6- R E E R SZ VF V S0700 VQ Residual pressure release valve spacer Z- VQ VQ VQC VQC 80. (0) 6 0. (0) 0. (8). () 06 Residual pressure release valve spacer (Z- ) R E E E E R VQZ SQ VFS VFR VQ7 Dimensions inside ( ) are for sub-plate aperture /8 and /. Dimensions inside are for sub-plate aperture /. 77

34 Series VQ7-6/VQ7-8 Manifold Option arts/mounting olt art No. VQ7-6 Mounting olt art No. Number of options Mounting bolt No. 0 Single stack Double stack XT6-- XT6-- XT6-- XT6-- XT6--6 XT6--7 XT6--8 XT6-- XT6--0 XT6-- XT6-- XT6-- Size M x with SW M x with SW M x with SW M x 60 with SW M x 6 with SW M x 70 with SW M x 7 with SW M x 0 with SW M x with SW M x 00 with SW M x 0 with SW M x with SW Option mounting diagram Throttle valve spacer () Interface regulator () () Throttle valve spacer () Release valve spacer () () () Throttle valve spacer () () Valve lanking plate Main exhaust back pressure check plate Note ) Note ) Number of options Triple stack Mounting bolt No. Size XT6-- XT6--6 XT6--7 XT6--8 XT6-- M x 0 with SW M x 0 with SW M x with SW M x 0 with SW M x with SW Option mounting diagram Throttle valve spacer () () () () Throttle valve spacer () () () Note ) Note ) () () Throttle valve spacer Note ) () () () Note ) The installation position of spacer () in the option mounting diagrams is limited only by the precautions given below. s Main EXH back pressure check plate Throttle valve spacer Release valve spacer () () Individual SU spacer Interface regulator ( port regulation) Individual EXH spacer Interface regulator ( port regulation) R, R individual EXH spacer Interface regulator ( port regulation) Reverse pressure spacer Double check spacer Residual pressure release valve spacer Double check spacer with residual Individual SU spacer with residual pressure release valve pressure release valve Note ) throttle valve spacer and double check spacer (including those with residual pressure release valve) cannot be combined. Note ) When a double check spacer (Top) (including those with residual pressure release valve) and individual EXH spacer (ottom) are combined with a R, R individual EXH spacer (ottom), be careful regarding the installation position. Note ) When an interface regulator (Top) and double check spacer (ottom) (including those with residual pressure release valve) (ottom) are combined, be careful regarding the installation position. VQ7-8 Mounting olt art No. Number of options Mounting bolt No. Size 0 Single stack Double stack XT6-- XT6-- XT6-- XT6-- XT6--6 XT6--7 XT6--8 XT6-- XT6--0 XT6-- M6 x with SW M6 x 8 with SW M6 x with SW M6 x 8 with SW M6 x 00 with SW M6 x 0 with SW M6 x with SW M6 x 0 with SW M6 x with SW M6 x 60 with SW Option mounting diagram () Interface regulator Double check spacer Interface regulator () Interface regulator Double check spacer () () () Double check spacer Valve lanking plate Main exhaust back pressure check plate Number of options Mounting No. bolt Size Option mounting diagram Triple stack XT6-- XT6-- XT6-- XT6-- M6 x 6 with SW M6 x 80 with SW M6 x 8 with SW M6 x 00 with SW () () Throttle valve spacer Interface regulator Throttle valve spacer () Double check spacer () () Interface regulator Double check spacer () s Main EXH back pressure check plate Interface regulator ( port regulation) Interface regulator ( port regulation) Interface regulator ( port regulation) Double check spacer () Individual SU spacer Individual EXH spacer R, R individual EXH spacer Reverse pressure spacer Residual pressure release valve spacer Throttle valve spacer Release valve spacer Note ) throttle valve spacer and double check spacer cannot be combined. Note ) There is no limitation on the mounting position for spacer (). Note ) When a double check spacer (Top) (including those with residual pressure release valve) and individual EXH spacer (ottom) are combined with a R, R individual EXH spacer (ottom), be careful regarding the installation position. Note ) When an interface regulator (Top) and double check spacer (ottom) (including those with residual pressure release valve) (ottom) are combined, be careful regarding the installation position. 78

35 ISO Standard Solenoid Valve Series VQ7-6/VQ7-8 Exploded View of Manifold/VQ7-6 D side end plate assembly Tension bolt Manifold block assembly U side end plate assembly SJ SV J SZ VF V S0700 VQ VQ VQ VQC VQC VQZ <End late ssembly> XT0 End plate position L R, R port size 0 0 C U side D side XT0 / /8 One-touch fitting for ø <Manifold lock ssembly> orting specifications Cylinder port size 0 0 C6 () C8 () C0 () Side ottom / /8 One-touch fitting for ø6 One-touch fitting for ø8 One-touch fitting for ø0 Note ) Side piping only Note ) In this manifold block assembly, the tension bolt for increasing station ( station) is included. T NTF Note) It is not applicable to One-touch fittings. Cylinder port location L R T NTF Note) It is not applicable to One-touch fittings. L side R side <Tension olt art No.> XT0 0 Stations For stations For stations For 0 stations Replacement arts (For manifold block) art no. XT0- XT0-0 XT0-- XT0- M x 8 Note) These tie-rods are solid pieces for each number of stations. Description O-ring O-ring late Oval countersunk head screw Material NR NR SCC NR SWRH 7 SQ VFS VFR VQ7

36 Series VQ7-6/VQ7-8 Exploded View of Manifold/VQ7-8 D side end plate assembly Manifold block assembly U side end plate assembly <End late ssembly> <Manifold lock ssembly> XT XT End plate position L R, R port size 0 06 C U side D side / / One-touch fitting for ø T NTF Note) It is not applicable to One-touch fittings. orting specifications Cylinder port size 0 0 /8 / Side ottom Cylinder port location L R L side R side Replacement arts (For manifold block) F T G NTF art no. Description Material XT- O-ring NR S68-0 O-ring NR S68-00 O-ring NR XT- NR XT- late SCC 6 M x 0 Oval countersunk head screw SWRH 7 XT-6- Connection fitting SCC 8 XT-6- Connection fitting SS XT-6- Hexagon socket head screw SCM 70

5 Port Solenoid Valve

5 Port Solenoid Valve Metal Seal ort Solenoid Valve Series VQ7-6/7-8 Rubber Seal ISO Standard Size /Size VQ7-8/Single unit.6 VQ7-8/Manifold. Conforms to ISO standard /I Interface conforms to ISO standard Size (VQ7-6) and Size

More information

Inrush Apparent power (VA) Flow Characteristics/Weight. Port size Rc. Valve model VS3115-01 VS3115-02 VS3110-02 VS3110-03 VS3114-00.

Inrush Apparent power (VA) Flow Characteristics/Weight. Port size Rc. Valve model VS3115-01 VS3115-02 VS3110-02 VS3110-03 VS3114-00. Port Direct Operated Solenoid Valve Series VS5/0 Metal Seal Multiple pressure supply is possible with balanced spool sleeve. Any given port can accept high or low pressure supply without affecting the

More information

3 Port Solenoid Valve

3 Port Solenoid Valve ubber Seal ort Solenoid Valve Series SYJ00/00/700 [Option] SYJ VQZ V VG Improved pilot valve ilot valve cover is stronger using stainless steel. Mounting thread is also reinforced from size M1.7 to M.

More information

5 Port Pilot Operated Solenoid Valve Rubber Seal. Specifications Fluid Operating pressure range. 2 position single/3 position 2 position double

5 Port Pilot Operated Solenoid Valve Rubber Seal. Specifications Fluid Operating pressure range. 2 position single/3 position 2 position double For details about certified products conforming to international standards, visit us at www.smcworld.com. 5 Port Pilot Operated Solenoid Valve Rubber Seal Series VF3000 Compact and lightweight: 26.4 mm

More information

0.35 0.9. 3 Port Solenoid Valve. Series VQZ100/200/300. Compact, High Flow. Power consumption: 0.35 W/0.9 W SYJ VQZ VP VG VP3

0.35 0.9. 3 Port Solenoid Valve. Series VQZ100/200/300. Compact, High Flow. Power consumption: 0.35 W/0.9 W SYJ VQZ VP VG VP3 Port Solenoid Valve 00/00/00 Metal Seal Rubber Seal 0. 0.9 (Standard) (High pressure type, High speed response type) Power consumption: 0. W/0.9 W Compact, High Flow Body ported Base mounted 00 00 00 00

More information

3 Port Solenoid Valve

3 Port Solenoid Valve Port Solenoid Valve Series V00 Rubber Seal Power consumption 0. W (with power saving circuit) VV0 VV00 V00 -V F VS temperature rises: C (with power saving circuit) Sonic conductance Series Standard Large

More information

5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported. Flow characteristics 1 4/2 (P A/B) 4/2 5/3 (A/B R1/R2)

5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported. Flow characteristics 1 4/2 (P A/B) 4/2 5/3 (A/B R1/R2) For details about certified products conforming to international standards, visit us at www.smcworld.com. 5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported Model position position Type of actuation

More information

2 position single. (Standard) 100V AC 50/60Hz 200V AC 50/60Hz 24V DC. 2 position double

2 position single. (Standard) 100V AC 50/60Hz 200V AC 50/60Hz 24V DC. 2 position double 4/ Port Solenoid Valve Rubber Seal VZ1000/000/000 Solenoid Valve Variations Port Size Effective area (mm 2 ) Position solenoid Voltage Electrical entry Option/ Indicator light and surge voltage suppressor

More information

5.0 MPa Pilot Operated 2/3 Port Solenoid Valve & Check Valve

5.0 MPa Pilot Operated 2/3 Port Solenoid Valve & Check Valve 5.0 Ma ilot Operated /3 ort Solenoid Valve & Check Valve Series VCH VCH4/4: ort VCH40: 3 ort VCHC40: Check Valve ilot Operated ort Solenoid Valve [Option] Series VCH40 Stable responsiveness Response time

More information

NAMUR Mount Hygienic Valve

NAMUR Mount Hygienic Valve NF097-D NMUR Mount Hygienic Valve For Wash Down pplications Series VFN Features Engineered Plastic PPS Body (Polyphenylene Sulfide) provides high temperature and chemical/corrosion resistance for use in

More information

Standard Specifications Model. How to Order. Mist spray unit. Recommended Equipment. Mixing valve

Standard Specifications Model. How to Order. Mist spray unit. Recommended Equipment. Mixing valve Mist Spray Unit Series MU/ Intermittent spray to cutting and press gear chains, etc. Standard Specifications MU MU Inlet air Oil tank set range. MPa. to. MPa Oil tank capacity (cm ) Total capacity: Effective

More information

4/2-Way Pneumatic Solenoid Valve

4/2-Way Pneumatic Solenoid Valve 4/2-Way Pneumatic Solenoid Valve Robust servo assisted piston valve Service friendly manual override Single or block assembly Explosion-proof versions Type 5413 cam be combined with Type 2508 Cable plug

More information

Process Valve. 2 Port Valve For Compressed Air and Air-hydro Circuit Control

Process Valve. 2 Port Valve For Compressed Air and Air-hydro Circuit Control Process Valve Series VN Port Valve For Compressed ir and ir-hydro Circuit Control Exclusively for air pressure system and air-hydro circuit control Universal Port Valve [Option] Cylinder actuation by external

More information

Specifications. Model Flow type Pressure type. Air Maximum operating pressure. 1.0 MPa Ambient and fluid temperature. 3% F.S.

Specifications. Model Flow type Pressure type. Air Maximum operating pressure. 1.0 MPa Ambient and fluid temperature. 3% F.S. Electro-Pneumatic Proportional Valve Series /VEP Electro-pneumatic proportional valve: Flow type () Controls the flow rate steplessly according to current. (It is a / port valve that has an electrical

More information

Assisted lift operated 2/2-way solenoid valves Type EV250B

Assisted lift operated 2/2-way solenoid valves Type EV250B MAKING MODERN LIVING POSSIBLE Data sheet Assisted lift operated 2/2-way solenoid valves Type EV250B EV250B with assisted lift can operate from zero and up to 10 bar differential pressure. This 2/2-way

More information

Valve systems Base plates, according to standard ISO 5599-1. Brochure

Valve systems Base plates, according to standard ISO 5599-1. Brochure ISO 5599-1 Brochure 2 ISO 5599-1 Single subbase Single subbase, thread connections on the side standard: ISO 5599-1 Frame size: ISO 1 - ISO 4 compressed air connection output: G 1/4 - G 1 Reversed pressure

More information

Unit 24: Applications of Pneumatics and Hydraulics

Unit 24: Applications of Pneumatics and Hydraulics Unit 24: Applications of Pneumatics and Hydraulics Unit code: J/601/1496 QCF level: 4 Credit value: 15 OUTCOME 2 TUTORIAL 4 DIRECTIONAL CONTROL VALVES The material needed for outcome 2 is very extensive

More information

2/2 and 3/2 Way Size 6 Seat Valves

2/2 and 3/2 Way Size 6 Seat Valves 2/2 and 3/2 Way Size 6 Seat Valves Directly operated Interface and subplate dimensions according to DIN 24340 and ISO Line connection port size G 3/8" Cartridge design PN [p max. ] = 315 bar 7501856.06.12.08

More information

Cartridge Valves. Solenoid Valves. Vickers. Screw-in Cartridge Valves. Maximum Pressure 210 bar (3000 psi) Maximum Flow 227 l/min (60 USgpm)

Cartridge Valves. Solenoid Valves. Vickers. Screw-in Cartridge Valves. Maximum Pressure 210 bar (3000 psi) Maximum Flow 227 l/min (60 USgpm) Vickers Cartridge Valves Solenoid Valves Screw-in Cartridge Valves Maximum Pressure bar ( psi) Maximum Flow 7 l/min (6 USgpm) Rev /99 77 Introduction For over seventy years, Vickers has provided its customers

More information

Check Valves. Pilot Operated Check Valves. Vickers. PCGV-6/8, 10 Series; PCG5V-6/8, 20 Series. Typical Section. Features and Benefits

Check Valves. Pilot Operated Check Valves. Vickers. PCGV-6/8, 10 Series; PCG5V-6/8, 20 Series. Typical Section. Features and Benefits Vickers Check Valves Pilot Operated Check Valves PCGV-6/8, 10 Series; PCG5V-6/8, 20 Series Typical Section Typical PCG5V model with internally drained pilot piston internal leakage through the closed pilot

More information

Proportional relief valves type AGMZO-TERS, AERS two stage, with integral or remote pressure transducer, ISO 6264 size 10, 20 and 32

Proportional relief valves type AGMZO-TERS, AERS two stage, with integral or remote pressure transducer, ISO 6264 size 10, 20 and 32 www.atos.com Table F040-1/E Proportional relief valves type AGMZO-TERS, AERS two stage, with integral or remote pressure transducer, ISO 6264 size 10, 20 and 32 AGMZO are two stage poppet type proportional

More information

Electrically operated valves Series M-05, 3/2-, 5/2- and 5/3-way G1/8 650 and 750 Nl/min (0.661 and 0.762 Cv)

Electrically operated valves Series M-05, 3/2-, 5/2- and 5/3-way G1/8 650 and 750 Nl/min (0.661 and 0.762 Cv) Electrically operated valves Series M-05, 3/2-, 5/2- and 5/3-way G1/8 650 and 750 Nl/min (0.661 and 0.762 Cv) Order code Series and function M-05-310-HN-442 Standard coil HN at ports 2 + 4 HN at ports

More information

3/2-way Mini Solenoid Valve

3/2-way Mini Solenoid Valve 3/2way Mini Solenoid Valve Directacting 0... bar DN mm... DN mm,,, subbase, banjobolt connection 21mm coil spacing when mounted on manifold Type can be combined with... Type 20 Type 207 Type able plug

More information

Directional Control Valves

Directional Control Valves echnical Information General he D1VW Series directional control valves are highperformance, 4-chamber, direct operated, wet armature solenoid controlled, 3 or 4-way valves. hey are available in 2 or 3-position

More information

3/2- and 2/2-way cartridge valve type BVE

3/2- and 2/2-way cartridge valve type BVE 3/2- and 2/2-way cartridge valve type BVE for any flow direction, zero leakage, all ports pressure resistant Flow Q max = 70 lpm Perm. pressure p max = 400 bar Additional valves with same function: ' Type

More information

Precision Regulator. Series IR1000/2000/3000 ARJ AMR ARM ARP IR IRV VEX1 SRH SRP SRF ARX20 VCHR ITV IC PVQ VER VEA VY2 AP100.

Precision Regulator. Series IR1000/2000/3000 ARJ AMR ARM ARP IR IRV VEX1 SRH SRP SRF ARX20 VCHR ITV IC PVQ VER VEA VY2 AP100. Precision Regulator Series // Basic Type Air Operated Type Series Model Regulating pressure range Page Series Series Series Series Series.5 to MPa. to MPa. to.8 MPa /8 55.5 to MPa. to MPa /4 55. to.8 MPa.

More information

UM/22000 5/2 or 5/3 Solenoid and air pilot actuated soft spool valves

UM/22000 5/2 or 5/3 Solenoid and air pilot actuated soft spool valves U/ / or / > > Sub-base mounted, 99- s,, or > > Steel reinforced main seals > > Low power coils (,W) > > Wide range of sub-bases and accessories > > 6 bar and bar NOO solenoid pilots with locking or non-locking

More information

Fluid. Flu. Fluid Fluid. uid Power d Power P. Fluid Power P. Fluid Power. Fluid Power Power. d Power. Directional Cetop Valves DCV 03.

Fluid. Flu. Fluid Fluid. uid Power d Power P. Fluid Power P. Fluid Power. Fluid Power Power. d Power. Directional Cetop Valves DCV 03. Catalogue Directional Cetop Valves DCV 03 Power Flu uid Power d Power P wer Power Power Power Power Power d Power Power Power ower Power Power wer Power Power P Power Power Powe d Power Power Power Power

More information

E4E PILOT OPERATED DIRECTIONAL CONTROL VALVE WITH ELECTRIC PROPORTIONAL CONTROL SERIES 51

E4E PILOT OPERATED DIRECTIONAL CONTROL VALVE WITH ELECTRIC PROPORTIONAL CONTROL SERIES 51 83 300/100 ED E4E PILOT OPERATED DIRECTIONAL CONTROL VALVE WITH ELECTRIC PROPORTIONAL CONTROL SUBPLATE MOUNTING CETOP P05 p max 250 bar Q max (see specification table) MOUNTING INTERFACE OPERATING PRINCIPLE

More information

3 WAY (3/2) POPPET VALVES FOR AIR AND VACUUM SERVICE SOLENOID OR AIR ACTUATED BROCHURE N-223

3 WAY (3/2) POPPET VALVES FOR AIR AND VACUUM SERVICE SOLENOID OR AIR ACTUATED BROCHURE N-223 3 WAY (3/2) POPPET VALVES FOR AIR AND VACUUM SERVICE SOLENOID OR AIR ACTUATED BROCHURE N-223 HERION S HIGH PERFORMANCE POPPET VALVES For those applications requiring high Cv, fast response times, large

More information

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv) Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv) Order code Series and function 1) Plug socket see page 5.042. MN-06-310-HN-442 Standard coil 1) 441 = 12 V DC, 4.2 W 442 = 24 V DC,

More information

Chapter 6: Check Valves

Chapter 6: Check Valves Contents Chapter : Check Valves Series Description Size Mounting Page Parker Standard DIN / ISO 1/8 1/4 3/8 1/2 3/4 1 0 10 1 25 32 Shuttle valves SSR -2 Check valves, direct operated RK / R CS SPZE SPV

More information

UM/22000 5/2 & 5/3 valves, solenoid and pilot actuated ISO 5599-1, ISO size 1, 2, 3 & 4 Sub-base mounted

UM/22000 5/2 & 5/3 valves, solenoid and pilot actuated ISO 5599-1, ISO size 1, 2, 3 & 4 Sub-base mounted U/ / & / valves, solenoid and pilot actuated ISO 99-, ISO size,, & Sub-base mounted Steel reinforced main seals 6 bar and bar NOO solenoid pilots with locking or non-locking manual override Low power coils

More information

Direct Operated Regulator for 6.0 MPa (Relieving Type) How to Order. Body size 30 40

Direct Operated Regulator for 6.0 MPa (Relieving Type) How to Order. Body size 30 40 Direct Operated Regulator for (Relieving Type) Series Service life: 0 million cycles Using NSF-H-certified grease on the guide ring (sliding) part. Improved durability under a high environment with a polyurethane

More information

size 3 15 4200 size 4 19 6600

size 3 15 4200 size 4 19 6600 BE/BE ISO 99/ Valves - Compliance with ISO 99/ international standards - Full range: - - - size - Two different internal commutation system: mixed and spool, appreciated for decades thanks to their maximum

More information

Control- and feedback head for integrated mounting on Robolux valves Type 2036

Control- and feedback head for integrated mounting on Robolux valves Type 2036 Control- and feedback head for integrated mounting on Robolux valves Type 203 Type 885 Type 88 can be combined with Compact stainless steel design Contactless valve position registration Coloured illuminated

More information

3-Way heavy duty flow control, with pressure compensated and solenoid controlled priority flow

3-Way heavy duty flow control, with pressure compensated and solenoid controlled priority flow 1/6 RE 18309-3/06.10 Replaces: RE 18309-3/04.10 3-Way heavy duty flow control, with pressure compensated and solenoid controlled priority flow A-VRFC3C-VEI-VS 0M.43.20.80 - Y - Z Description The flow control

More information

Oil Pressure Regulating Valve

Oil Pressure Regulating Valve Oil ressure Regulating Valve In adopting and using this product. Safety recautions ype Number Index 2 3 4 Directional control valve - ressure control valve 2- Flow control valve 3- Sandwich valve 4- Logic

More information

4 Posiflow Proportional Solenoid Valves

4 Posiflow Proportional Solenoid Valves 4 Posiflow Solenoid Brass or Stainless Steel Bodies 1/4" to 1/2" NPT 2/2 Features Flow rates adjustable between 0% and 100% of rating Flow rate can also be regulated by a range of electrical inputs (sensors,

More information

G1/4 Q8. Standard with biased position

G1/4 Q8. Standard with biased position Contents Version Actuation Page Characteristics Dimensions x / Way Valves pneumatic 6,7, 0 9 electric 6,7 9, 9 / Way Valves pneumatic 6,7, 0 electric 6,7, 0 / Way Valves pneumatic 6,7,, 6, 7 electric 6,7,,

More information

Chapter 5: Flow Valves

Chapter 5: Flow Valves Catalogue HY11-300/UK Contents Chapter : Flow Valves Series Description Size Mounting Page Parker Standard DIN / ISO 1/4 3/8 1/2 3/4 1 06 10 16 Throttle valves, manual adjustment MVI -2 NS -4 FS With free

More information

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics 3/2-, 5/2-5/3-way Solenoid Valves for process pneumatics Type 6518 stard High flow-rate capacity Reduced power consumption Single or manifold mounting stard Type 6518/6519 can be combined with... Stard-,

More information

3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve

3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve 3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve Type 6518 Type 6519 Type 6518/6519 can be combined with... Single or block mounting Suitable for outdoor and chemical atmospheres Suitable for

More information

VC Series Zone Valves BALANCED 2-WAY AND 3-WAY HYDRONIC VALVES

VC Series Zone Valves BALANCED 2-WAY AND 3-WAY HYDRONIC VALVES VC Series Zone Valves BALANCED 2-WAY AND 3-WAY HYDRONIC VALVES PRODUCT DATA Design VC Series zone valves consist of: 2-way or 3-way valve housing available with various connection ends Spindle and cartridge

More information

SOLENOID VALVES 3-4 WAY

SOLENOID VALVES 3-4 WAY SOLENOID VLVES - WY IE/C// CT: FP/VCR Page: 7 SHEET: / SOLENOID VLVES - - WY CV SOLENOID VLVES -WY/-POSITION /- UNF.7 5.7 The electric valve is a -way -position directional electrically controlled Slight

More information

SOLENOID VALVES AND PNEUMATIC VALVES

SOLENOID VALVES AND PNEUMATIC VALVES 2 A S E R I E S Catalogue 2005-2006 Directly operated solenoid valves Series A 2/2 way, 3/2 way monostable, bistable (with magnetic memory) Ports M5,, cartridge ø4 The Series A solenoid valves are of the

More information

Single sub-base valve

Single sub-base valve solenoid valves Mini-valves 10 mm Electrical connection... Mounting... Port sizes... Rated temperature... Fluid... Working pressure... Nominal flow... Pneumatic connections Voltage... Power... NC poppet

More information

Electro-hydraulic pressure switches type DG

Electro-hydraulic pressure switches type DG Electro-hydraulic pressure switches type DG Pressure p max = 700 bar See also: For electronic pressure switches type DG 5 E see D 5440 E Analogous pressure transducer type DT 1 see D 5440 T Analogous pressure

More information

3/2-way Solenoid Valve, direct-acting, NC or NO

3/2-way Solenoid Valve, direct-acting, NC or NO 3/2-way Solenoid Valve, direct-acting, NC or NO Electrical connection cable plug, Form A With or without manual override as standard Threaded port and sub-base s Impulse optional Type 6014 can be combined

More information

Valves. Sub-Base Mounted Valves to ISO 5599/2

Valves. Sub-Base Mounted Valves to ISO 5599/2 Valves Sub-Base Mounted Valves to ISO 5599/2 General Information ISO 1, ISO 2 and ISO 3 valve series incorporate the famous Numatics lapped spool and sleeve for ultimate service life. Due to the great

More information

1.8 w 101.2. 3 Port Solenoid Valve Direct Operated Poppet Type. New. Series VT307 CAT.ES11-107A. Power consumption

1.8 w 101.2. 3 Port Solenoid Valve Direct Operated Poppet Type. New. Series VT307 CAT.ES11-107A. Power consumption Port Solenoid Valve Direct Operated Poppet Type Power consumption Vacuum applications New [Option] RoHS 4 Standard wtype (Existing product: 4.8 W) 0. kpa Energy-saving type.8 w (Existing product: W) A

More information

Pressure Relief. Pressure Control Valve R(C)G(O)-03, 06 and 10; R(C)T(O)-03, 06 and 10 VICKERS. Basic Characteristics. Sectional Illustrations

Pressure Relief. Pressure Control Valve R(C)G(O)-03, 06 and 10; R(C)T(O)-03, 06 and 10 VICKERS. Basic Characteristics. Sectional Illustrations VICKERS Pressure Relief Pressure Control Valve R(C)G(O)-03, 06 and 10; R(C)T(O)-03, 06 and 10 Sectional Illustrations RCG-** Model Shown RCT-** Model Shown Basic Characteristics Type...................

More information

No. : EX##-OMF0004 OPERATION MANUAL. SI unit EX12#-SMB1

No. : EX##-OMF0004 OPERATION MANUAL. SI unit EX12#-SMB1 No. : EX##-OMF0004 OPERATION MANUAL EX12#-SMB1 Contents 1. Safety instructions ------------------------------------------------------ P3 2. Notes ------------------------------------------------------

More information

Proportional pressure regulators VPPE

Proportional pressure regulators VPPE Proportional pressure regulators VPPE Proportional pressure regulators VPPE Product range overview Function Version Pneumatic connection Proportional pressure regulator Nominal size for pressurisation/

More information

Sensors. Sensors. All Cylinders. Specifications. Features: Features Type REED HALL EFFECT NPN or PNP. Ø8mm - 125mm

Sensors. Sensors. All Cylinders. Specifications. Features: Features Type REED HALL EFFECT NPN or PNP. Ø8mm - 125mm Specifications Features Type REED HALL EFFECT NPN or PNP Applicable Series Configurations Construction Materials Body Mounting Bracket Cable Characteristics Operating Temperature Accuracy All Cylinders

More information

2-Way heavy duty flow control, with pressure compensated, solenoid and load sensing controlled priority flow

2-Way heavy duty flow control, with pressure compensated, solenoid and load sensing controlled priority flow 2-Way heavy duty flow control, with pressure compensated, solenoid and load sensing controlled priority flow RE 18309-64/04.10 1/6 Replaces: RE 00171/02.07 A-VRFC2C-VEI-VS-LS 0M.28.03.80 - Y - Z Description

More information

Electro-pneumatic control valves

Electro-pneumatic control valves Electropneumatic control valves 7 Miniature solenoid valves for alternating current Conform to the Low Voltage Directive or mounting on subbase or footprint in accordance with CNOMO recoendation E 066120N

More information

3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve

3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve 3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve Type 6518 Type 6519 Type 6518/6519 can be combined with... Single or block mounting Suitable for outdoor and chemical atmospheres Suitable for

More information

http://www.daikinpmc.com/en/ For latest information, PDF catalogs and operation manuals Features MPa {kgf/cm 2 } 100 17.5 {175}

http://www.daikinpmc.com/en/ For latest information, PDF catalogs and operation manuals Features MPa {kgf/cm 2 } 100 17.5 {175} Solenoid Valve Features 2 For DC power supply 3 For C power supply These models realize high-pressure large-flow-rate control at 35 MPa {35 kgf/cm 2 } and 1 L/min (2) or 16 L/min (3). They are best suited

More information

Directional seated valves type VP 1

Directional seated valves type VP 1 Directional seated valves type VP 1 zero leakage, intended for general hydraulic applications and grease lubing systems Flow Q max Operation pressure p max = 15 lpm = 400 bar Individual valve Individual

More information

Solenoid Valve Type 3962

Solenoid Valve Type 3962 Solenoid Valve Type 362 x d, x em or without explosion protection, for controlling pneumatic actuators General The Type 362 Solenoid Valve ensures a high level of operational reliability for controlling

More information

97300 NAMUR series, 3/2 & 5/2 Indirect solenoid actuated spool valve

97300 NAMUR series, 3/2 & 5/2 Indirect solenoid actuated spool valve 9700 NAMUR series, / & / > > Port size: G/, / NPT, NAMUR Interface > > Crossover-free switching > > Main application: Single and double acting actuators > > / way valve usable as / way valve > > Manual

More information

Hydraulic Flow Control Valves

Hydraulic Flow Control Valves Webtec Products Limited Hydraulic Flow Control Valves Quality Hydraulic Components from the Webtec Range CONTENTS DESCRIPTION PAGE No. ILFC Series Fixed Flow Pressure Compensated Control Valve 1 VFC Series

More information

How To Use A Flowmeter

How To Use A Flowmeter INLINE flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both PNP and NPN) Connection

More information

RPE3-04. Functional Description HA 4014 10/2010. Directional Control Valves Solenoid Operated. Replaces HA 4014 12/2007

RPE3-04. Functional Description HA 4014 10/2010. Directional Control Valves Solenoid Operated. Replaces HA 4014 12/2007 Directional Control Valves Solenoid Operated RPE3-04 Size D 04 (02) 320 bar (4600 PSI) 30 L/min(8.0 GPM) HA 4014 10/2010 Replaces HA 4014 12/2007 4/3-, 4/2- way directional control valves with solenoid

More information

SPOOL & SLEEVE VALVES solenoid air operated monostable / bistable function threaded ports G 1/8-G 1/4

SPOOL & SLEEVE VALVES solenoid air operated monostable / bistable function threaded ports G 1/8-G 1/4 SPOO & SV VAVS monostable / bistable function threaded ports -G 1/ 5/-5/3 Series 1 FATURS Reliability: steel spool & sleeve technology with long service life Robust valve design, particularly recommended

More information

KDG3V-5/7/8, 10 Series

KDG3V-5/7/8, 10 Series Vickers roportional Valves KDG3V-5/7/8, 1 Series Single-Stage with Hydraulic ilot Operation High Flow roportional Directional Control Valves asic Characteristics Max. pressure.......... up to 35 bar (5

More information

2.12. page 223 2.12. Products for Explosion hazardous Environment

2.12. page 223 2.12. Products for Explosion hazardous Environment 2.12 page 223 2.12 Products for Explosion hazardous Environment Non-electric valves for explosion 2.12.1 page 224 hazardous environment The following manually and mechanically actuated valves are available

More information

RT series Miniature Printed Circuit Board Relays, Sockets and Accessories

RT series Miniature Printed Circuit Board Relays, Sockets and Accessories s RT series Miniature Printed Circuit oard Relays, Sockets and ccessories pplied Coil Voltage (% of rated nom.) RT series (DC Coil) 6 mp PC oard Miniature Relay Meets VDE 0mm Spacing, KV Dielectric File

More information

Oildyne. 165 Series Hydraulic Power Units. Pressures to 241 bar (3500 psi) Flows to 5.4 lpm (1.4 gpm)

Oildyne. 165 Series Hydraulic Power Units. Pressures to 241 bar (3500 psi) Flows to 5.4 lpm (1.4 gpm) Oildyne Hydraulic Power Units Pressures to 241 bar (3500 psi) Flows to 5.4 lpm (1.4 gpm) 11 Power Unit Features We are pleased to introduce our new power units. The power units let you put more power where

More information

Solenoid valves 2/2-way direct-operated Type EV210A

Solenoid valves 2/2-way direct-operated Type EV210A Solenoid valves 2/2-way direct-operated Type EV210A Features EV210A NC and NO Very compact valves for industrial application, such as control and dosage For water, oil, compressed air and similar neutral

More information

Water Separator. Main Line Filter. Mist Separator. Micro Mist Separator 150C 250C 350C 450C AMG 550C 2C 4C 8C 11C AFF 22C 37B 75B 150C 250C 350C 450C

Water Separator. Main Line Filter. Mist Separator. Micro Mist Separator 150C 250C 350C 450C AMG 550C 2C 4C 8C 11C AFF 22C 37B 75B 150C 250C 350C 450C Water droplet removal Water Separator Water droplet separation rate: % Model Flow capacity l/min (ANR) Max. flow capacity at 0.7 MPa inlet pressure 300 750 1,500 AMG 2,0 AMG to AMG/ Large dust particle

More information

VSO MAX HP High Flow Proportional Valve

VSO MAX HP High Flow Proportional Valve VSO MAX HP High Flow Proportional Valve Typical Applications Ventilators Insufflators Anesthesia Delivery & Monitors Pressure & Flow Control Mass Flow Control Product Specifications Physical Properties

More information

MANTA Piston Distributor for Oil and Fluid Grease

MANTA Piston Distributor for Oil and Fluid Grease MANTA Piston Distributor for Oil and Fluid Grease Function Piston distributors meter out and distribute the oil delivered by an intermittently actuated pump. The quantities of oil for the individual lube

More information

% ^ ) 0.55 W Low Power Solenoid Valves Aluminum, Brass, or Stainless Steel Bodies 1/4" to 1" NPT. 2/2 3/2 4/2 5/2 5/3 SERIES Low Power

% ^ ) 0.55 W Low Power Solenoid Valves Aluminum, Brass, or Stainless Steel Bodies 1/4 to 1 NPT. 2/2 3/2 4/2 5/2 5/3 SERIES Low Power .55 W Solenoid Valves Aluminum, Brass, or Stainless Steel Bodies /" to " NPT / 3/ / 5/ 5/3 Features Molded one-piece solenoid with highly efficient solenoid cartridge and.55 W low wattage coil Standard

More information

1. General. D 7490/1 2/2-way cartridge valve EM 2.2. Operation pressure p max Flow Q max. = 450 bar = 160 lpm. Cartridge valve (see section 2)

1. General. D 7490/1 2/2-way cartridge valve EM 2.2. Operation pressure p max Flow Q max. = 450 bar = 160 lpm. Cartridge valve (see section 2) 2/2-way directional seated s type EM and EMP for oil hydraulic systems, leakage free in blocked state, available as on/off, soft-shift or proportional Operation pressure p max Flow Q max = 4 bar = 0 lpm

More information

Air Catch Sensor. Series ISA. For Workpiece Placement Confirmation

Air Catch Sensor. Series ISA. For Workpiece Placement Confirmation Air Catch Sensor Series For Workpiece Placement Confirmation No-contact sensor for confirming workpiece placement, with a configuration that is less affected by supply pressure change. Easy-to-set-up LED

More information

How To Read A Pipe From A Sensor

How To Read A Pipe From A Sensor Liquid Level Sensor Installation on pipes. Sensing by means electrostatic capacity and is not influenced by the color of the pipe or liquid. Available in 8 to mm dia. and to mm dia. models to enable sensing

More information

VP23, 3-way proportional pressure control valves Seat valve with μp-driven pressure control

VP23, 3-way proportional pressure control valves Seat valve with μp-driven pressure control VP, -way proportional pressure control valves > > Port size: G/... G/ > > All-digital control electronics > > Variable pressure control > > Optional actuation via fieldbus (separate datasheet on request)

More information

type V46, solenoid or pneumatic operated

type V46, solenoid or pneumatic operated SPECIFICATION general type of construction spool valve operator solenoid or pneumatic operated or by manual override. Manual override is equipped with a monostable function (push) and a bistable function

More information

Position Transducers with Restoring Spring 10, 25, 50, 75, 100 mm TR, TRS Series

Position Transducers with Restoring Spring 10, 25, 50, 75, 100 mm TR, TRS Series Position Transducers with Restoring Spring 10, 25, 50, 75, 100 mm TR, TRS Series Special features long life 100 x 10 6 movements outstanding linearity up to ±0.075% choice of plug or cable connection DIN

More information

XE70 SERIES VC SERIES BALANCED HYDRONIC VALVES 2-WAY AND 3-WAY

XE70 SERIES VC SERIES BALANCED HYDRONIC VALVES 2-WAY AND 3-WAY XE70 SERIES VC SERIES BALANCED HYDRONIC VALVES 2-WAY AND 3-WAY PRODUCT SPECIFICATION SHEET switched off. This results in energy savings during mild weather. Normal control will resume when T3 fails to

More information

Clear Glass Sensor. Ordering Information E3S-CR67/62. Optimum Sensor for Detecting Transparent Glass and Plastic Bottles

Clear Glass Sensor. Ordering Information E3S-CR67/62. Optimum Sensor for Detecting Transparent Glass and Plastic Bottles Clear Glass Sensor Optimum Sensor for Detecting Transparent Glass and Plastic Bottles E3S-CR67/62 Retroreflective Sensor smoothly detects 5-mm gaps. Detects transparent bottles that have a lens effect.

More information

System 8. ü www.nassmagnet.com ( +49 511 6746-0. System 8

System 8. ü www.nassmagnet.com ( +49 511 6746-0. System 8 System 8 ü www.nassmagnet.com ( +9 11 7-0 System 8 The name System 8 stands for a modular system of solenoid coils, armature systems, solenoid operators and solenoid valves. The diameter of the armatures

More information

Why and How we Use Capacity Control

Why and How we Use Capacity Control Why and How we Use Capacity Control On refrigeration and air conditioning applications where the load may vary over a wide range, due to lighting, occupancy, product loading, ambient weather variations,

More information

Universal type. Elbow type AS13 1FG-M5 AS23 1FG-01 AS23 1FG-02 AS33 1FG-02 AS33 1FG-03 AS43 1FG-04. Specifications

Universal type. Elbow type AS13 1FG-M5 AS23 1FG-01 AS23 1FG-02 AS33 1FG-02 AS33 1FG-03 AS43 1FG-04. Specifications Speed Controller with One-touch Fitting Stainless Steel Series Elbow Type/Universal Type Series -FG RoHS Stainless specifications for use in corrosive environments. Stainless steel used for metal parts.

More information

On-off valves MS-EM/EE, MS series, NPT

On-off valves MS-EM/EE, MS series, NPT On-off valves MS-EM/EE, MS series, NPT On-off valves MS9-EM, MS series, NPT Peripherals overview 5 3 4 aa -H- Note Additional accessories: Module connector for combinations with size MS6, MS9 or size MS12

More information

Oil and Coolant Circulating Heating System. Model - OCSM

Oil and Coolant Circulating Heating System. Model - OCSM Oil and Coolant Circulating Heating System Model - OCSM Installation & Operation Manual 216280-000 REV 2 Identifying Your System The HOTSTART heating system is designed to heat fluids for use in marine

More information

Electro-Pneumatic Bus Door Control Mechanism

Electro-Pneumatic Bus Door Control Mechanism Electro-Pneumatic Bus Door Control Mechanism Application and Feature 1. Pneumatic Door Mechanism actuates the open/close movements of bus door through two double acting cylinders and two linkages with

More information

Hydraulic control unit series 0086-372-01

Hydraulic control unit series 0086-372-01 Technical Product Information No. 1290 EN Hydraulic control unit series 0086-372-01 Contents Page About this Technical Product Information (TPI) 2 The ORTLINGHAUS numbering system 2 About the product 3

More information

DXPE*J 85 320/215 ED. DIRECtIONAL CONtROL VALVE PILOt OPERAtED, WItH OBE AND FEEDBACK. Q max (see performance table) SERIES 30

DXPE*J 85 320/215 ED. DIRECtIONAL CONtROL VALVE PILOt OPERAtED, WItH OBE AND FEEDBACK. Q max (see performance table) SERIES 30 85 320/215 ED DXPE*J DIRECtIONAL CONtROL VALVE PILOt OPERAtED, WItH OBE AND FEEDBACK SUBPLAtE MOUNtINg DXPE5J CEtOP P05 DXPE5RJ ISO 4401-05 (CETOP R05) DXPE7J ISO 4401-07 (CETOP 07) DXPE8J ISO 4401-08

More information

PILOT OPERATED PRESSURE RELIEF VALVE - Series VR4V

PILOT OPERATED PRESSURE RELIEF VALVE - Series VR4V PILOT OPERTED PRESSURE RELIEF VLVE - Series VR4V The Veljan Pressure Relief Valve series VR4V are pilot operated and wk Internal Dra on the prciple of hydraulic balancg. These valves are used to limit

More information

KA/8000/M, KA/8000, ISO cylinder (Stainless steel) Magnetic & Non-magnetic piston, double acting

KA/8000/M, KA/8000, ISO cylinder (Stainless steel) Magnetic & Non-magnetic piston, double acting K/8000/M, K/8000, ISO cylinder (Stainless steel) > > Ø 3... 00 mm > > High corrosion and acid resistance > > Ideal for applications in the food industry > > Conforms to DIN ISO 555, DIN ISO 63, VDM 56

More information

INDUSTRIAL DIRECT DRIVEN PISTON COMPRESSORS CL - CH - CK

INDUSTRIAL DIRECT DRIVEN PISTON COMPRESSORS CL - CH - CK INDUSTRIAL DIRECT DRIVEN PISTON COMPRESSORS CL - CH - CK CL - CH - CK Direct driven solution for industry Proven technology, solid construction The CL - CH - CK units are directly driven air-cooled, single

More information

Cable Plug acc. to DIN EN 175301-803, Form A

Cable Plug acc. to DIN EN 175301-803, Form A Cable Plug acc. to DIN EN 175301-803, Form A Complete program Contact form 18 mm Also available with LED indicator Optional 4-pin version for pressure switch or impulse valves respectively Versions with

More information

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points Features SELV Compliant No Detection Passive Injector Gigabit Compatible Full Protection

More information

Line-Mounted Valves L Series

Line-Mounted Valves L Series Spare Part Kit for Valve Series B1LSAD3 Line-Mounted L Series Accessories Spare Part Kits All Series Valve Series B1LSAD3 40.1609 Incl. O-rings, gaskets, spring or muffl er Spare Part Kit for Valve Series

More information

In addition, a number of auxiliary options are available (para 2.7) as well as optional slices for special requirements (para 2.8).

In addition, a number of auxiliary options are available (para 2.7) as well as optional slices for special requirements (para 2.8). DS3002 1. General Description This data sheet describes the Modular Power (MP) Electro Hydraulic Power Units, which have been designed to provide an advanced and flexible means of brake control. The MP

More information

technical data air conditioning systems RXS20-25-35E (single phase) FBQ-B8V1-B8V3B Split Heat Pump Condensing Units Split Sky Air

technical data air conditioning systems RXS20-25-35E (single phase) FBQ-B8V1-B8V3B Split Heat Pump Condensing Units Split Sky Air technical data RXS20-25-35E FBQ-B8V-B8V3B (single phase) Split Heat Pump Condensing Units air conditioning systems Split Sky Air Outdoor Units R-40A RXS-E2VB Split Sky Air Outdoor Units Features O u t

More information

TS93 EMR T/PT/TDE. Surface applied door closer

TS93 EMR T/PT/TDE. Surface applied door closer TS EMR T/PT/TDE Surface applied door closer Installation instructions: Pull side track mount door closer with smoke detector (EMR T) Push side track mount door closer with smoke detector (EMR PT) Double

More information