AN INNOVATIVE GREEN FILTER FEATURING

Size: px
Start display at page:

Download "AN INNOVATIVE GREEN FILTER FEATURING"

Transcription

1 Max 5 I/min - bar Featuring prefiltration by means of a magnetic column Extended element life time AN INNOVATIVE GREEN FILTER FEATURING LEIF LEIF The TTF Series features pre-filtration by means of a magnet column and a quick response bypass with low hysteresis. Maximum pressure bar. Maximum flow 5 l/min. A second return port is an available option as is a filling port in the filter cover. Contact Information: European Product Information Centre Freephone: (from AT, BE, CH, CZ, DE, EE, ES, FI, FR, IE, IT, PT, SE, SK, UK) filtrationinfo@parker.com Product Features: TTF features pre-filtration by means of a magnet column. Quick response bypass with low hysteresis. Maximum pressure bar. Maximum flow 5 l/min. Options include a filling port in the filter cover and second return port. Patented LEIF elements safeguard filtration quality. Flow from inside to out. 2 FDHB5UK.

2 Features & Benefits Features bar rated filter Cast aluminium head LEIF elements Magnetic pre-filtration In-to-Out filtration High level of customisation Quick response bypass with low hysteresis Standard or customised funnel Advantages Can be utilised for severe return line applications Compact profile, lightweight and durable Element safeguards the use of genuine parts Removes ferrous particles, even during bypass conditions All captured contamination retains inside the element Dedicated system-matched solutions can be easily made available Reduction of bypass period due to low hysteresis Only a small part of the total flow is bypassing the element Ensures that oil enters the tank under the oil level Benefits Reduced downtime due to premature filter failures Less weight, smaller envelop and cleaner appearance Guaranteed quality of filtration Contributes to ISO 4 certification Improved fluid cleanliness levels Extended element life time No recontamination of system during change of elements Improved integration of filter in system combined with lower initial system costs Improved protection of system Significant reduction of oil foaming Typical Applications Waste management trucks Mobile cranes Power packs Wheeled loaders Drilling equipment The Parker Filtration TTF Series Return Line Filters TTF tank top mounted return line filters feature pre-filtration by means of a magnet column and a quick response bypass with low hysteresis. Thanks to the In-to-Out filter principle, contaminated oil cannot leak back into the system. TTF filters are available in versions capable of handling flow rates up to 5 l/min. They can operate up to a maximum working pressure of bar. Optional filling port in filter cover, second return port and customised diffusers can be specified. 22 FDHB5UK.

3 Specification Operation pressure: Max. bar. Assembly: Tank top mounted. Connections: Threaded BSP ports. Flanged ports on request. Filter housing: Aluminium head and cover. Seal material:, fluoroelastomer, neoprene. Operation temperature range: Seal material : -4 to + C. Seal material Fluoroelastomer: -2 to +2 C. Bypass setting Opening pressure.8 /.5 or 2 bar. Other settings on request. Degree of filtration: Determined by multipass test according to ISO Flow fatigue characteristics: Filter media is supported so that the optimum fatigue life is achieved. Filtration media: Microglass III and Ecoglass III for LEIF elements. Also available µm cellulose and 4µm stainless steel mesh. Element collapse rating: bar (ISO 294) Pressure indicator options: Setting.7 or.2 bar. Other settings on request. Visual pressure gauge. Electrical pressure switch. Options: Diffuser type P (straight pipe, no perforated plate area) Diffuser type T (with closed diffuser end cap and with perforated plate area, recommended when oil entry in reservoir is close to the reservoir bottom or to ensure oil entry under the reservoir oil level) Magnetic pack: Standard. TTF4 and 5 are standard supplied without magnets Filling port in cover: (optional). Filter element: LEIF element with reusable metal element sleeve. Optional conventional style element with steel end caps. The LEIF element is patented and safeguards the use of genuine parts. Note: LEIF element can be used with mineral and HEES type oils. For other fluids consult Parker Filtration. LEIF contributes to ISO 4 quality standards. TTF 9a 9b TTF sealkit: No Ref. No. Description 4 Flange nut 3 Cover 4 Cover-seal 5 Top-spring 6 Insert 7 Insert-seal 8 Element 9a - Indicator 9b -3 Plug Mx -3 Unit-ring Housing 2 Gasket 3 Sleeve 4 Funnel/diffuser 5 O-ring 6 Bypass set FDHB5UK.

4 MAX 5 I/min - bar TTF Lengths 2-5 Single port TTF length Type 2 TTF -6 3 TTF -9 4 TTF -2 5 TTF -5 Dimensions in mm Port option h h ØD ØD H H2 H3 b R R R2 K FP G 3 /4, G Ø9 Ø xØ G /2 TTF Lengths 6- Single port TTF length Type 6 TTF TTF TTF TTF 2-4 TTF 2-5 Dimensions in mm Port option h h ØD ØD H H2 H3 b R R R2 K FP G¼, G½ Ø32 Ø xØ G¾ FDHB5UK.

5 TTF Lengths 2-5 Dual port H2 H TTF length A 5 4B Type TTF -6 TTF -9 TTF -2 TTF -4 TTF -5 TTF -75 Port option A - B h h ØD ØD H H2 b R R R2 K FP G - G 3 74 Ø88 Ø xØ G /8 Dimensions in mm TTF Lengths 6- Dual port TTF length Type 6 TTF TTF TTF 2-3 9** TTF 2-4 ** TTF 2-5 Dimensions in mm Dual Port option A-B h h ØD ØD H H2 H3 R R R2 K FP G /2 - G /2 G2 - G /2 SAE /2 - G / Ø32 Ø xØ G FDHB5UK.

6 Pressure Drop Curves The recommended level of the initial pressure drop for low pressure filters is max.5 bar. If the medium used has a viscosity different from 32cSt, pressure drop over the filter can be estimated as follows: Dp = (Dp32 x viscosity of medium used) / 32cSt. TTF6 (Element length code 2) TTF9 (Element length code 3) Q Q Q Q Q Q Q.2 2Q TTF2 (Element length code 4) TTF5 (Element length code 5) Q Q Q Q 2Q Q.4 Q.2 2Q FDHB5UK.

7 Pressure Drop Curves (cont.) The recommended level of the initial pressure drop for low pressure filters is max.5 bar. If the medium used has a viscosity different from 32cSt, pressure drop over the filter can be estimated as follows: Dp = (Dp32 x viscosity of medium used) / 32cSt. TTF7 (Element length code 6) TTF23 (Element length code 7) Q Q.5 Q 7.3 2Q TTF3 (Element length code 8) Q 3. 5Q Q Q TTF4 (Element length code 9) Q Q Q Q TTF5 (Element length code ) Q Q Q 2Q Q Q 2Q Q FDHB5UK.

8 Pressure Drop Curves (cont.) TTF6 (Element length code 2) TTF9 (Element length code 3) C 4W C 4W TTF2 (Element length code 4) TTF5 (Element length code 5) C W C 4W TTF7 (Element length code 6) TTF23 (Element length code 7) C 4W C 4W TTF3 (Element length code 8) C W FDHB5UK.

9 Indicator Options Indicator PS pressure switch Protective cap with dual cable duct for, 7-2, 3mm diameter cable Indicator PS NO/NC pressure switch Protective cover Normally open contacts Amp 6.3x8 terminals Switch 74 Normally closed contacts A/F = COM. 2 = N.C. 3 = N.O A/F 9 9 Mx G /8 (BSP) Ø3.5 Ø28 Elec.rating Thread connection Elec.connection Protection TTF Specifications 42V / 4A Mx AMP 6.3x.8 terminals + protective cap IP65 (with cap) terminals IP FMUSEBMML (Switch) Indicator Connection / Filter Head Matrix Port(s) Filter head ISO 228-G 3 /4" (BSP) (TTF length 2,3,4 and 5) ISO 228-G" (BSP) ISO 228-G /4" (BSP) (TTF length 6 and larger) 2xISO 228-G /4" (BSP) (TTF length 6 and larger) ISO 228-G /2"(BSP) (TTF length 6 and larger) 2xISO 228-G /2"(BSP) (TTF length 6 and larger) /2" SAE-3 PSI (TTF length 6 and larger) /2" SAE-3 PSI (2nd port) + G /2" (TTF length 6 and larger) G2" (TTF length 6 and larger) G2" + G /2" (TTF length 6 and larger) Indicator Thread M M M G/8" M G/8" G/8" G/8" G/8" G/8" Specifications Elec.rating 42V / 2A Thread connection G /8 Elec.connection AMP terminal 6.3x.8 Protection IP65 (terminal IP) Switch type NO or NC FMUS2EBMG2L (NO switch) FMUS3EBMG2L (NC switch) Visual indicator.2 bar M: code FMUGEBPML G /8: code FMUG2EBPG2L Ordering Information Standard products table Part number Supersedes TTF3QLBP2EG2 TTF9-G 3 /4 TXWL3- B5 MM TTF32QLBP2EG2 TTF9-G 3 /4 TXWL3-2 B5 MM TTF5QLBP2EG6 TTF25-G TXWL3E- B5 MM TTF52QLBP2EG6 TTF25-G TXWL3E-2 B5 MM TTF6QLBP2EG23 TTF7-G /4 TXWL4- T B5 MM TTF62QLBP2EG23 TTF7-G /4 TXWL4-2 T B5 MM TTF8QLBP2EG243 TTF3-G /2 TXWL5A- T B5 MM TTF82QLBP2EG243 TTF3-G /2 TXWL5A-2 T B5 MM TTFQLBP2HG24A TTF5-G /2 TXWL5C- T B2 MM NMG TTFQLBP2HG24A TTF5-G /2 TXWL5C-2 T B2 MM NMG Flow (l/min) Model number Element length TTF9 Length 3 TTF9 Length 3 TTF25 Length 5 TTF25 Length 5 TTF7 Length 6 TTF7 Length 6 TTF3 Length 8 TTF3 Length 8 TTF5 Length TTF5 Length Media rating (µ) Note: Filter assemblies ordered from the product configurator on the next page are on extended lead times. Where possible, please make your selection from the table above Seals Indicator Bypass settings.5 Bar (22 Psi).5 Bar (22 Psi).5 Bar (22 Psi).5 Bar (22 Psi).5 Bar (22 Psi).5 Bar (22 Psi).5 Bar (22 Psi).5 Bar (22 Psi) 2. Bar (29 Psi) 2. Bar (29 Psi) Ports G 3 /4 G 3 /4 G G G /4 G /4 G /2 G /2 G /2 G /2 Included options None None None None Diffuser type T Diffuser type T Diffuser type T Diffuser type T Diffuser type T Diffuser type T Replacement elements Q Q Q Q Q Q Q Q Q 93787Q Supersedes TXWL3- TXWL3-2 TXWL3E- TXWL3E-2 TXWL4- TXWL4-2 TXWL5A- TXWL5A-2 TXWL5C- TXWL5C-2 29 FDHB5UK.

10 Ordering Information (cont.) Product configurator Configurator example of a TTF Series filter Box TTF Box 2 9 Box 3 5QL Box 4 V Box 5 S3 Box 6 H Box 7 L24 Box 8 Box TTF Box 2 Filter type Housing TTF -6 TTF -9 TTF -2 TTF -4 TTF -75 TTF -5 TTF 2-7 TTF 2-23 TTF 2-3 TTF 2-4 TTF A 4B Box 3 Element media Disposable element LEIF element Cellulose Nom. rating C Degree of filtration Glass fibre Microglass III (for disposable elements) Ecoglass III (for Leif elements) 2Q 2QL 5Q 5QL Q QL 2Q 2QL Wire mesh Abs. rating 4W Box 4 Seal material Fluorelastomer Neoprene Seal type B V On request Box 5 Indicator Pressure gauge, setting.2 bar, Mx* Pressure gauge, setting.2 bar, G /8 for dual head ports Pressure switch 42V,.2 bar setting, NO/NC, Mx* Pressure switch 42V,.2 bar setting, NO with G /8 BSP* Pressure switch 42V,.2 bar setting, NC with G /8 BSP* Pressure switch 25V, NO/NC with G /8* Pressure switch 22V, NO/NC with M* No indicator, indicator ports not machined No indicator, indicator ports L + R plugged Other settings for indicators / gauges on request G G2 S S2 S3 S4 S5 On request P2 on request Box 6 Bypass valve Bypass valve.8 bar.5 bar 2. bar for TTF series Blocked bypass Other bypass settings B E H X on request Note: * HEAD HAS PLUGGED INDICATOR CONNECTIONS L+R Note: Also see the table indicator Connection/Filter Head Matrix on page 29 Box 7 Filter connection Ports ISO 228-G 3 /4" (BSP) (TTF length 2,3,4 and 5) ISO 228-G" (BSP) (TTF length 2,3,4 and 5) ISO 228-G /4" (BSP) (TTF length 6 and larger) ISO 228-G /2" (BSP) (TTF length 6 and larger) 2xISO 228-G /2" (BSP) (TTF length 6 and larger) /2" SAE-3 PSI (TTF length 6 and larger) /2" SAE-3 PSI (2nd port) + G /2" (TTF length 6 and larger) G2" (TTF length 6 and larger) G2" + G /2" (TTF length 6 and larger) G2 G6 G2 G24 2G24 On request LD24 On request GM32 Box 8 Options Options No diffuser required Diffuser type T with perforated plate area Diffuser type P without perforated plate area Funnel with integrated hose connection for TTF lengths 2, 3 and 4 No magnets filling port Diffuser type T and no magnets Diffuser type P and no magnets Diffuser type T, no magnets, plugged filling port Diffuser type P, no magnets, plugged filling port Air tight diffuser type T Air tight diffuser type P Other combinations 3 4 On request 5 8 A B C D G H on request Note: TTF size 2-4 and 2-5 are standard supplied without magnets. ßx(c)=2 5.% 6 Degree of filtration Average filtration beta ratio ß (ISO 6889) / particle size µm [c] ßx(c)= ßx(c)=75 ßx(c)= ßx(c)=2 ßx(c)= % efficiency, based on the above beta ratio (ßx) 9.% 6 9% % % % Media code 2Q/2QL 5Q/5QL Q/QL 2Q/2QL Highlights Key (Denotes part number availability) Item is standard Item is standard green option Item is semi standard Item is non standard Note: Standard items are in stock, semi standard items are available within four weeks 3 FDHB5UK.

11 Ordering Information (cont.) Supersedes Spare Element table (TXWL & PXWL replaced by 9 number) TTF6 TTF9 TTF2 TTF25 TTF7 TTF23 TTF3 TTF4 TTF5 TXWL Q TXWL Q TXWL3D Q TXWL3E Q TXWL Q TXWL Q TXWL5A Q TXWL5B Q TXWL5C Q TXWL Q TXWL Q TXWL3D Q TXWL3E Q TXWL Q TXWL Q TXWL5A Q TXWL5B Q TXWL5C Q TXWL Q TXWL Q TXWL3D Q TXWL3E Q TXWL Q TXWL Q TXWL5A Q TXWL5B Q TXWL5C Q TXWL Q TXWL Q TXWL3D Q TXWL3E Q TXWL Q TXWL Q TXWL5A Q TXWL5B Q TXWL5C Q Supersedes Spare Element table (TXW & TXX replaced by 9 number) TTF6 TTF9 TTF2 TTF25 TTF7 TTF23 TTF3 TXX2--B TXX3--B TXX3D--B TXX3E--B TXX4--B TXX5--B TXX5A--B TXW2-2-B 93775Q TXW3-2-B 93775Q TXW3D-2-B Q TXW3E-2-B Q TXW4-2-B Q TXW5-2-B Q TXW5A-2-B Q TXW2-5-B Q TXW3-5-B Q TXW3D-5-B Q TXW3E-5-B Q TXW4-5-B Q TXW5-5-B Q TXW5A-5-B 93776Q TXW2--B Q TXW3--B Q TXW3D--B Q TXW3E--B Q TXW4--B Q TXW5--B Q TXW5A--B 93778Q TXW2-2-B 93779Q TXW3-2-B 93779Q TXW3D-2-B Q TXW3E-2-B Q TXW4-2-B Q TXW5-2-B Q TXW5A-2-B Q ST2-4-B ST3-4-B ST3D-4-B ST3E-4-B ST4-4-B ST5-4-B ST5A-4-B TTF Series Seal Kit TTF Filter connections Seal Kit Ports Part Number ISO 228-G 3 /4 (BSP) (TTF length 2,3,4 and 5) 2492 ISO 228-G (BSP) (TTF length 2,3,4 and 5) 2492 ISO 228-G /4 (BSP) (TTF length 6 and larger) xISO 228-G /4 (BSP) (TTF length 6 and larger) ISO 228-G /2 (BSP) (TTF length 6 and larger) xISO 228-G /2 (BSP) (TTF length 6 and larger) /2 SAE-3 PSI (TTF length 6 and larger) /2 SAE-3 PSI (2nd port) + G /2 (TTF length 6 and larger) G2 (TTF length 6 and larger) G2 + G /2 (TTF length 6 and larger) FDHB5UK.

12 Notes 32 FDHB5UK.

In-Tank Mounted Return Line Filters. IN-AGB Series. MAX 2400 I/min LEIF LEIF FILTER FEATURING AN INNOVATIVE GREEN. Low pressure filters

In-Tank Mounted Return Line Filters. IN-AGB Series. MAX 2400 I/min LEIF LEIF FILTER FEATURING AN INNOVATIVE GREEN. Low pressure filters MAX I/min AN INNOVATIVE GREEN FILTER FEATURING LEIF LEIF Low pressure filters Features & Benefits Features Filter integrated in tank LEIF elements Magnetic pre-filtration In-to-Out filtration igh level

More information

Hydraulic Filtration & Contamination Control Products. Catalogue: FDHB200UK January 2007

Hydraulic Filtration & Contamination Control Products. Catalogue: FDHB200UK January 2007 Hydraulic Filtration & Contamination Control Products Catalogue: FDHB2UK January 27 Consistent quality Technical innovation Premier customer service Hydraulic, Lubrication & Coolant Filtration High-performance

More information

BGAH Series. Medium Pressure Filters Max. 500 l/min. 25 bar. In-line solution for a straight pipeline. Applications: Contact Information:

BGAH Series. Medium Pressure Filters Max. 500 l/min. 25 bar. In-line solution for a straight pipeline. Applications: Contact Information: BGAH Series Medium Pressure Filters Max. 500 l/min. 25 bar In-line solution for a straight pipeline Pre-filtration by magnet column and a full-flow bypass with low hysteresis. Contamination-proof in-out

More information

Tanktop Mounted Return Line Filters. BGT Series. MAX 2400 I/min - 10 bar LEIF LEIF FILTER FEATURING AN INNOVATIVE GREEN. Low pressure filters

Tanktop Mounted Return Line Filters. BGT Series. MAX 2400 I/min - 10 bar LEIF LEIF FILTER FEATURING AN INNOVATIVE GREEN. Low pressure filters GT Series X 2 I/min - bar N INNOVTIV GRN FITR FTURING IF IF 2 ow pressure filters GT Series Features & enefits Features bar rated filter ast aluminium head IF elements agnetic pre-filtration In-to-Out

More information

LEIF LEIF. BGT Series. Tanktop Mounted Return Line Filters Max. 2400 I/min - 10 bar. Patented LEIF elements safeguard filtration quality

LEIF LEIF. BGT Series. Tanktop Mounted Return Line Filters Max. 2400 I/min - 10 bar. Patented LEIF elements safeguard filtration quality GT Series Tanktop ounted Return ine Filters ax. 24 I/min - bar atented IF elements safeguard filtration quality When high flow performance is needed N INNOVTIV GRN FITR FTURING IF IF The GT Series features

More information

Eco130 Series. Medium Pressure Filters Max. 1400 l/min. 30 bar. Modular system for industrial applications. Applications: Contact Information:

Eco130 Series. Medium Pressure Filters Max. 1400 l/min. 30 bar. Modular system for industrial applications. Applications: Contact Information: Eco130 Series Medium Pressure Filters Max. 1400 l/min. 30 bar Modular system for industrial applications High flow return filters for industrial use on hydraulic or lubrication systems. High flow and pressure

More information

Eco130 Series. Medium Pressure Filters Max. 1400 l/min. 30 bar. Modular system for industrial applications. Applications: Contact Information:

Eco130 Series. Medium Pressure Filters Max. 1400 l/min. 30 bar. Modular system for industrial applications. Applications: Contact Information: Eco130 Series Medium Pressure Filters Max. 1400 l/min. 30 bar Modular system for industrial applications High flow return filters for industrial use on hydraulic or lubrication systems. High flow and pressure

More information

15/40/80CN Series Medium Pressure Filters Max. 600 I/min - 70 bar

15/40/80CN Series Medium Pressure Filters Max. 600 I/min - 70 bar 1/4/8CN Series Max. 6 I/min - 7 bar Premium performance for medium pressure applications FEATURING An economical multipurpose filter solution The CN Series utilizes a cast aluminium head and spin-on bowl

More information

15/40/80CN Series Medium Pressure Filters

15/40/80CN Series Medium Pressure Filters 1/4/8CN Series Medium Pressure Filters Max 32 l/min - 7 bar Global Filtration Technology 1/4/8CN Series TYPICAL APPLICATIONS Compressor Lube Oil Off-line Filter Loops Machine Tools (Automotive Standard)

More information

HFS and HFD Series. High Flow Single and Duplex Filters Max. 11200 l/min. 10 bar. Heavy Duty Reliability. Applications: Contact Information:

HFS and HFD Series. High Flow Single and Duplex Filters Max. 11200 l/min. 10 bar. Heavy Duty Reliability. Applications: Contact Information: High Flow Single and Duplex Filters Max. 11200 l/min. 10 bar Heavy Duty Reliability New High Flow Single and Duplex Filters ensure reliability in industrial, marine, and power generation applications up

More information

OUT. The SF2 series suction filter are designed for reservoir side-wall applications. This completely new design of filter allows the filter

OUT. The SF2 series suction filter are designed for reservoir side-wall applications. This completely new design of filter allows the filter D e s c r i p t i o n 250 The SF2 series suction filter are designed for reservoir side-wall applications. This completely new design of filter allows the filter within the filter preventing oil loss from

More information

Return line filters. Return line filters

Return line filters. Return line filters Return line filters Return line filters Index Technical data - 5 Filters series 6 Filters series --3 8 ccessories Spare parts Uni-ardan Italia S.p.. reserves the right to make technical changes to the

More information

15/40/80CN Series Coreless Medium Pressure Filters

15/40/80CN Series Coreless Medium Pressure Filters //8CN Series Coreless Medium Pressure Filters //8CN Series Applications Compressor Lube Oil Off-line Filter Loops Machine Tools (Automotive Standard) Hydrostatic Drive Charge Pumps Mobile Equipment Pilot

More information

High Pressure Filters. 70/70 Eco Series. MAX 450 I/min -420 bar FEATURING. High pressure filters

High Pressure Filters. 70/70 Eco Series. MAX 450 I/min -420 bar FEATURING. High pressure filters 7/7 Eco eries MAX 5 I/min - bar FEATURING 5 High pressure filters 7/7 Eco eries Features &enefits Features Fatigue tested to full pressure rating everal head options and connection sizes everal bowl lengths

More information

New. absolute filter elements independently tested in the following Institutes: MPH-MPI 02050/7.99/USA 2 COVER INSERT

New. absolute filter elements independently tested in the following Institutes: MPH-MPI 02050/7.99/USA 2 COVER INSERT e s c r i p t i o n MPH and MPI series filters are designed for returnline applications and provide various installation applications. The filters are installed semiimmersed or totally immersed into a

More information

12CS Series Coreless Spin-on Filter Max. 75 l/min - 35 bar

12CS Series Coreless Spin-on Filter Max. 75 l/min - 35 bar 2CS Series Coreless Spin-on Filter Max. 7 l/min - 3 bar Environmentally friendly alternative for spin-on filtration Lightweight, non-metallic element that can be incinerated The 2CS Series features a Parker,

More information

NORMAN FILTER COMPANY PRODUCT OVERVIEW

NORMAN FILTER COMPANY PRODUCT OVERVIEW NORMAN FILTER COMPANY PRODUCT OVERVIEW LEADING THE WAY IN QUALITY FILTRATION WWW.NORMANFILTERS.COM FILTER ELEMENT INTERCHANGE Tee-Type Filter 4500, 14500, 34500, and 54500 Series Mini Tee-Type Filter 4100

More information

The SF2 series are designed for reservoir side-wall mounting applications, suitable for flow rates to 850 l/min and filtration from 25 to 250 micron.

The SF2 series are designed for reservoir side-wall mounting applications, suitable for flow rates to 850 l/min and filtration from 25 to 250 micron. D e s c r i p t i o n 500 The SF2 series are designed for reservoir side-wall mounting applications, suitable for flow rates to 850 l/min and filtration from 25 to 250 micron. A major feature of these

More information

HOW THE CONTAMINATION IS MEASURED CONTAMINATION CLASSES ACCORDING TO ISO 4406:1999

HOW THE CONTAMINATION IS MEASURED CONTAMINATION CLASSES ACCORDING TO ISO 4406:1999 CONTAMINATION CONTROL in hydraulic systems in the hydraulic system is a very wide and complex matter; the following is just a short summary. Our Customer Service is at your disposal for any further information.

More information

PVS Series - Models 185, 600, 1200, 1800 and 2700

PVS Series - Models 185, 600, 1200, 1800 and 2700 PVS Series - Models 185, 600, 1200, 1800 and 2700 Reduce the catastrophic results of water contamination Eliminate water from the hydraulic system The PVS Series Portable Purification Systems, available

More information

RMF TANDEM 900 OFF-LINE FILTER SYSTEMS

RMF TANDEM 900 OFF-LINE FILTER SYSTEMS RMF TANDEM 900 OFF-LINE FILTER SYSTEMS RMF Tandem 900 Off-line filter Systems can be applied to every imaginable industrial application where hydraulic or lubrication systems are present. An integrated

More information

MHT. Pressure Filters HIGH PRESSURE INLINE FILTER

MHT. Pressure Filters HIGH PRESSURE INLINE FILTER MHT Pressure Filters HIGH PEUE INLINE FILTE Pressure Filters MHT MHT 4 MPa ( bar) Port sizes: / / Flow rates: 0 l/min TEHNIAL DATA Max. working pressure: 4 MPa ( bar) Max. testing pressure: 6 MPa (60 bar)

More information

PVS 185, 600, 1200, 1800, 2700 Series Portable Purification Systems

PVS 185, 600, 1200, 1800, 2700 Series Portable Purification Systems 185, 600, 1200, 1800, 2700 Series Portable Purification Systems FEATURING Global Filtration Technology PRINCIPLES OF OPERATION Contaminated oil is drawn into the Parker Portable Purification System by

More information

Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS

Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS up to size 381; to PN 0.5; to T = 80 C 1. Description 1.1. General FSA fluid level gauges, FSK fluid level sensors and TS temperature

More information

DIESEL FUEL CONDITIONING

DIESEL FUEL CONDITIONING COD FILTRATION DIESEL FUEL CONDITIONING REMOVE WATER & PARTICLES TO EXTEND FUEL INJECTOR LIFE & INCREASE COMBUSTION ENGINE FUEL EFFICIENCY Remove free water to saturation point with high single pass efficiency

More information

Piston Accumulators. SK Series. Accumulator Catalog. Piston Types. Description. Sealing Systems. End Cap. O-ring. Sealing System. Piston.

Piston Accumulators. SK Series. Accumulator Catalog. Piston Types. Description. Sealing Systems. End Cap. O-ring. Sealing System. Piston. SK Series Piston Types TYPE 2 pplication: Low-friction design for higher piston speeds, slow movements without stick-slip effect and high number of actuations (millions). ctual cycles achieved will vary

More information

Check Valves Valve locator

Check Valves Valve locator Check Valves Valve locator Functional Symbol Flow Typical Model Cavity Rating Pressure Page Check valve, direct L/min (USgpm) bar (psi) FPR/4 Inline () 5 (5) - FPR/8 Inline (8) 5 (5) - FPR/ Inline 45 ()

More information

The Par-Gel Filter Water Removal Filter Elements

The Par-Gel Filter Water Removal Filter Elements Stopping free water causing system damage Increases system efficiency and machine productivity The Par-Gel filter elements are an effective tool in controlling water related problems in hydraulic power

More information

Duplex Filters 40/160 LD 0003-0045 40/160 LDN 0040-0400. Industrial Filters Accumulators. Filters for inline installation for continuous operation

Duplex Filters 40/160 LD 0003-0045 40/160 LDN 0040-0400. Industrial Filters Accumulators. Filters for inline installation for continuous operation Industrial Filters Accumulators Duplex Filters 40/160 LD 0003-0045 40/160 LDN 0040-0400 Filters for inline installation for continuous operation With integrated pressure equalisation valve Optimised flow

More information

Duplex Filters 40 FLDK 0008(C)-0120(C)

Duplex Filters 40 FLDK 0008(C)-0120(C) Industrial Filters Accumulators Duplex Filters 40 FLDK 0008(C)-0120(C) Filters for inline installation for continuous operating Ball valve change over Optimised flow characteristics by 3D computer aided

More information

Hydraulic Control Solutions

Hydraulic Control Solutions Hydraulic Control Solutions Vexve s Hydrox hydraulic control solutions are suitable for even the most challenging installation sites and conditions. Specifically designed for district heating and district

More information

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES BQ FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES Versatility, power, compactness and low running costs are the main characteristics of B&C vane pumps. All the components subject to wear are contained

More information

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES BQ FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES Versatility, power, compactness and low running costs are the main characteristics of B&C vane pumps. All the components subject to wear are contained

More information

USA Headquarters. Dynex/Rivett Inc. 770 Capitol Drive Pewaukee, WI 53072 U.S.A. Tel: 262-691-2222 FAX: 262-691-0312 E-mail: sales@dynexhydraulics.

USA Headquarters. Dynex/Rivett Inc. 770 Capitol Drive Pewaukee, WI 53072 U.S.A. Tel: 262-691-2222 FAX: 262-691-0312 E-mail: sales@dynexhydraulics. SPECIFICATIONS PF1000 Series Fixed Displacement Pumps Also refer to "Checkball Pump Installation and Operating Recommendations" Bulletin PSI.CB (dynexpumpinstallation.pdf) CONTACT INFORMATION USA Headquarters

More information

Filter Elements E 7.200.9/05.06

Filter Elements E 7.200.9/05.06 HYDAC Filter Elements safeguard the performance and service life of essential and expensive hydraulic components due to their high standard of quality Filter Elements Technical details: Absolute filtration

More information

E4E PILOT OPERATED DIRECTIONAL CONTROL VALVE WITH ELECTRIC PROPORTIONAL CONTROL SERIES 51

E4E PILOT OPERATED DIRECTIONAL CONTROL VALVE WITH ELECTRIC PROPORTIONAL CONTROL SERIES 51 83 300/100 ED E4E PILOT OPERATED DIRECTIONAL CONTROL VALVE WITH ELECTRIC PROPORTIONAL CONTROL SUBPLATE MOUNTING CETOP P05 p max 250 bar Q max (see specification table) MOUNTING INTERFACE OPERATING PRINCIPLE

More information

Solenoid valves 2/2-way direct-operated Type EV210A

Solenoid valves 2/2-way direct-operated Type EV210A Solenoid valves 2/2-way direct-operated Type EV210A Features EV210A NC and NO Very compact valves for industrial application, such as control and dosage For water, oil, compressed air and similar neutral

More information

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES BQ FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES Versatility, power, compactness and low running costs are the main characteristics of B&C vane pumps. All the components subject to wear are contained

More information

CSD WATER REMOVAL FILTERS FOR DIESEL

CSD WATER REMOVAL FILTERS FOR DIESEL CSD CSD WATER REMOVAL FILTERS FOR DIESEL Remove water to extend fuel injector life & increase combustion fuel efficiency Remove free water to saturation point with high single pass efficienc (achieve

More information

SMR Series Submicronic Removal Fluid Purifi cation Systems

SMR Series Submicronic Removal Fluid Purifi cation Systems SMR Series Submicronic Removal Fluid Purifi cation Systems 193 SMR Series Applications The SMR Series is the smart purification solution for fluid flow in the 2-10 GPM (8-38 LPM) range. The SMR contains

More information

Turbine Flow Sensor Series VTR

Turbine Flow Sensor Series VTR Turbine Flow Sensor Series VTR SIKA Turbine Flow Sensor Series VTR Extra robust, impressively precise SIKA s VTR turbine flow sensor allows you to determine precisely, dependably and easily the flow rates

More information

2 & 5-Wire Overfill Sensors

2 & 5-Wire Overfill Sensors 2 & 5-Wire Overfill Sensors Optic overfill sensors detect the presence of liquid at a preset level. The new Civacon Universal 2 & 5-Wire Sensor is fully compatible with all our current Sensors and Monitors,

More information

Pipe threads for tubes and fittings where pressure-tight joints are not made on the threads. (requires PTFE sealing tape or liquid sealant).

Pipe threads for tubes and fittings where pressure-tight joints are not made on the threads. (requires PTFE sealing tape or liquid sealant). Fittings for CO 2 Pipe Threads Pipe thread references quoted in this catalogue conform with the requirements specified in the latest issue and amendments of the following ISO Standards: ISO 7-1 (BS21)

More information

SERIES FRI. Maximum working pressure 20 bar Flow rate to 1200 l/min. s.p.a

SERIES FRI. Maximum working pressure 20 bar Flow rate to 1200 l/min. s.p.a SRIS FRI Maximum working pressure bar Flow rate to 1 l/min s.p.a R FRI series filter has been disigned and developed to satisfy the demands pf applications, on return or low preessure line in Hydraulic

More information

Truck Hydraulics. Series GPA, GP1, F1, F2, T1, VP1, Fixed and Variable Displacement Pumps, Motors and Accessories

Truck Hydraulics. Series GPA, GP1, F1, F2, T1, VP1, Fixed and Variable Displacement Pumps, Motors and Accessories Series GPA, GP1, F1, F2, T1, VP1, Fixed and Variable Displacement Pumps, Motors and Accessories Pumps and Motors Conversion factors 1 kg... 2,20 lb 1 N... 0,225 lbf 1 Nm... 0,738 lbf ft 1 bar...14,5 psi

More information

Open center control block in monoblock design MO-40

Open center control block in monoblock design MO-40 Open center control block in monoblock design MO-40 RE 64370 Edition: 02.2015 Replaces: 02.1985 Size 40 Series 1X Maximum working pressure on pump side 350 bar on consumer side 420 bar Maximum flow 680

More information

4" SUBMERSIBLE PUMPS

4 SUBMERSIBLE PUMPS 4" SUBMERSIBLE PUMPS 4" SUBMERSIBLE PUMPS 50/60 HZ Multi-stage centrifugal submersible pumps for clean water in 4" wells. The 4" VSP pump series is carefully designed and manufactured for maximum resistant

More information

V47 Series Temperature Actuated Modulating Water Valves

V47 Series Temperature Actuated Modulating Water Valves V47 Series Temperature Actuated Modulating Water Valves Master Catalog 125 Valves, Miscellaneous (Other Than Gas) Section V Product Bulletin V47 Issue Date 0286 Application The V47 modulating valves regulate

More information

Pressure Relief. Pressure Control Valve R(C)G(O)-03, 06 and 10; R(C)T(O)-03, 06 and 10 VICKERS. Basic Characteristics. Sectional Illustrations

Pressure Relief. Pressure Control Valve R(C)G(O)-03, 06 and 10; R(C)T(O)-03, 06 and 10 VICKERS. Basic Characteristics. Sectional Illustrations VICKERS Pressure Relief Pressure Control Valve R(C)G(O)-03, 06 and 10; R(C)T(O)-03, 06 and 10 Sectional Illustrations RCG-** Model Shown RCT-** Model Shown Basic Characteristics Type...................

More information

TAS ITA. DA1, dual csatlakozásfor thermostat. For control of 2 heaters on 1 thermostat. * * * * * * * * 41.729.220 Thermostat for CH 12/18

TAS ITA. DA1, dual csatlakozásfor thermostat. For control of 2 heaters on 1 thermostat. * * * * * * * * 41.729.220 Thermostat for CH 12/18 ACCESSORIES RT1, RT2, RT3 IT1 DA1 Thermostat for CH 12/18. Digital timer, burning and ventilating. Fault detector GSM. GSM temperature fault detector. THERMOSTATS RT1, room thermostat -10/+40 C with 5

More information

FILTRATION AMIAD PLASTIC FILTERS, SCREENS & DISCS

FILTRATION AMIAD PLASTIC FILTERS, SCREENS & DISCS 4 AMIAD PLASTIC FILTERS, SCREENS & DISCS Max pressure 10.0 Bar, max temperature 60 O 3/4 to 1 1/2 bodies manufactured from polyacetal 2 bodies and above manufactured from polymade and glass fibre 3/4 to

More information

SERIES FRI. Maximum working pressure 20 bar F l o w r a t e t o 1 2 0 0 l / m i n. s. p. a

SERIES FRI. Maximum working pressure 20 bar F l o w r a t e t o 1 2 0 0 l / m i n. s. p. a New Headquarters : MP FILTRI S.p.. Italy Via 1 Maggio, n. Pessano con ornago (Milano) Italy Tel. +9./97.1 Fax +9./9741497-974188 email: sales@mpfiltri.com http://www.mpfiltri.com GRT RITIN MP FILTRI U.K.

More information

SCP 012-130 ISO. Other advantages: SCP 012-130 ISO is a series of piston pumps with a fixed displacement for mobile and stationary hydraulics.

SCP 012-130 ISO. Other advantages: SCP 012-130 ISO is a series of piston pumps with a fixed displacement for mobile and stationary hydraulics. SCP 012-130 ISO is a series of piston pumps with a fixed displacement for mobile and stationary hydraulics. SCP 012-130 ISO covers the entire displacement range 12-130 cmᶟ rev. at a maximum pressure of

More information

Truck Hydraulics. Series GPA, GP1, F1, F2, T1, VP1, Fixed and Variable Displacement Pumps, Motors and Accessories. parker.com/pmde

Truck Hydraulics. Series GPA, GP1, F1, F2, T1, VP1, Fixed and Variable Displacement Pumps, Motors and Accessories. parker.com/pmde Series GPA, GP1, F1, F2, T1, VP1, Fixed and Variable Displacement Pumps, Motors and Accessories parker.com/pmde Pumps and Motors Conversion factors 1 kg... 2.20 lb 1 N... 0.225 lbf 1 Nm... 0.738 lbf ft

More information

Flow Control Valves. Note: Also see R04C3 on page DC1. Denotes New Winner s Circle Product Line. Catalog HY15-3502/US

Flow Control Valves. Note: Also see R04C3 on page DC1. Denotes New Winner s Circle Product Line. Catalog HY15-3502/US Catalog HY15-352/US Contents Control SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO. LPM/GPM BAR/PSI NEED VALVES J2A2... C8-2... Needle Valve, Cartridge Type...45/12... 42/6... 5-6 NVH81... C8-2... Needle

More information

Proportional pressure regulators VPPE

Proportional pressure regulators VPPE Proportional pressure regulators VPPE Proportional pressure regulators VPPE Product range overview Function Version Pneumatic connection Proportional pressure regulator Nominal size for pressurisation/

More information

Hydraulic Flow Control Valves

Hydraulic Flow Control Valves Webtec Products Limited Hydraulic Flow Control Valves Quality Hydraulic Components from the Webtec Range CONTENTS DESCRIPTION PAGE No. ILFC Series Fixed Flow Pressure Compensated Control Valve 1 VFC Series

More information

PVH131/141 Variable Displacement Piston Pump - 11 Design

PVH131/141 Variable Displacement Piston Pump - 11 Design Service Data Vickers Piston Pumps PVH131/141 Variable Displacement Piston Pump - 11 Design Revised 05/01/97 M-2209-S Maximum Adjustable Stop S Option 913341 Locknut Torque 25-50 N.m. (18-37 lb. ft.) Torque

More information

Spare Parts List M96A.24SM/B M96A.28SM/B

Spare Parts List M96A.24SM/B M96A.28SM/B *16202390* 162.0239.0 REV5 14/04 2015 Spare Parts List M96A.24SM/B M96A.28SM/B Issue Table description Issue n. of pages Overall view 09/2008 1 C.h. return group and d.h.w. heat exchanger 09/2008 1 C.h.

More information

Fixed displacement vane pumps

Fixed displacement vane pumps Fixed displacement vane pumps RE 1335/1.5 Replaces: 11.2 1/22 Types PVV and PVQ Nominal sizes 18 to 193 Series 1X Maximum operating pressure 21 bar Maximum displacement 18 to 193 cm 3 Doppelpumpe_d_ Double

More information

Single sub-base valve

Single sub-base valve solenoid valves Mini-valves 10 mm Electrical connection... Mounting... Port sizes... Rated temperature... Fluid... Working pressure... Nominal flow... Pneumatic connections Voltage... Power... NC poppet

More information

RUBBER SLEEVE KNIFE GATE VALVE

RUBBER SLEEVE KNIFE GATE VALVE RUBBER SLEEVE KNIFE GATE VALVE The model knife gate is a wafer valve designed for a wide range of industrial applications. The double-seated design provides bi-directional shut off. The design of the valve

More information

MANTA Piston Distributor for Oil and Fluid Grease

MANTA Piston Distributor for Oil and Fluid Grease MANTA Piston Distributor for Oil and Fluid Grease Function Piston distributors meter out and distribute the oil delivered by an intermittently actuated pump. The quantities of oil for the individual lube

More information

VARIABLE DISPLACEMENT AXIAL PISTON PUMPS. For truck applications

VARIABLE DISPLACEMENT AXIAL PISTON PUMPS. For truck applications VARIABLE DISPLACEMENT AXIAL PISTON PUMPS For truck applications TVP FEATURES Variable displacement axial piston pumps swash plate design ideally suited for open circuit truck applications. The compact

More information

*Rated to 207 Bar/3000 PSI with Aluminum Body. Denotes New Winner s Circle Product Line. Catalog HY15-3502/US

*Rated to 207 Bar/3000 PSI with Aluminum Body. Denotes New Winner s Circle Product Line. Catalog HY15-3502/US Bodies & Contents SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO. LPM/GPM BAR/PSI STANDARD CHECKS D1A6... 2U... Valve Insert, Ball Type...145/38... 42/6... 5 D1B125... 2C... Valve Insert, Ball Type...

More information

Aerospace and Defence

Aerospace and Defence Aerospace and Defence Hydraulic, Fuel, Lubrication and Air Systems World Class Filtration Solutions Porvair Filtration Group Aerospace and Defence Hydraulic, Fuel, Lubrication and Air Systems Porvair Filtration

More information

Safety at a high level!

Safety at a high level! SIKA Level Switch SIKA Level Switch Safety at a high level! Convincing Advantages easy and reliable method to monitor fluid levels proven float principle easy side installation using threads ¾" or ½" BSP

More information

Sensors. Sensors. All Cylinders. Specifications. Features: Features Type REED HALL EFFECT NPN or PNP. Ø8mm - 125mm

Sensors. Sensors. All Cylinders. Specifications. Features: Features Type REED HALL EFFECT NPN or PNP. Ø8mm - 125mm Specifications Features Type REED HALL EFFECT NPN or PNP Applicable Series Configurations Construction Materials Body Mounting Bracket Cable Characteristics Operating Temperature Accuracy All Cylinders

More information

Oil Filtration Systems. Filtakleen By-Pass Oil Filter INSTALLATION INSTALLATION & & SERVICE MANUAL MANUAL

Oil Filtration Systems. Filtakleen By-Pass Oil Filter INSTALLATION INSTALLATION & & SERVICE MANUAL MANUAL Filtakleen By-Pass Oil Filter Oil Filtration Systems INSTALLATION INSTALLATION & & SERVICE MANUAL MANUAL xx INTRODUCTION The Filtakleen By-Pass oil Filter is an ultra-fine 1 micron Bypass filtration system

More information

How To Order A Direct Flow Air Cleaner

How To Order A Direct Flow Air Cleaner Reduced Volume - Improved Performance - Flexible Packaging The patented Direct Flow technology provides the flexibility to optimize the air system performance to size ratio, meeting the demands of today

More information

SITRANS F flowmeters SITRANS F M

SITRANS F flowmeters SITRANS F M Overview Integration The complete flowmeter consists of a flow sensor and an associated transmitter MAG 5000, 6000 or 6000 I. The flexible communication concept USM II simplifies integration and update

More information

Pre-Filtration for Ultimate Cleanliness and Efficiency: HYDAC Diesel PreCare. Dual function: Diesel filtration + Water removal

Pre-Filtration for Ultimate Cleanliness and Efficiency: HYDAC Diesel PreCare. Dual function: Diesel filtration + Water removal Pre-Filtration for Ultimate Cleanliness and Efficiency: HYDAC Diesel PreCare. Dual function: Diesel filtration + removal Diesel PreCare: The Clear Link Guaranteed HYDAC quality thanks to HYDAC Quality

More information

Steering unit. Table of contents. Features RE 11872/05.06. Type LAGL. Frame sizes 500 to 1000 Component series 1X Maximum flow 80 l/min

Steering unit. Table of contents. Features RE 11872/05.06. Type LAGL. Frame sizes 500 to 1000 Component series 1X Maximum flow 80 l/min Steering unit RE 11872/05.06 /10 Type LAGL Frame sizes 500 to 1000 Component series 1X Maximum flow 80 l/min H7375 Table of contents Contents Page Features 1 Ordering code 2 Function, section 3 Device

More information

AIR-AIR PRESSURE MULTIPLIER (BOOSTER)

AIR-AIR PRESSURE MULTIPLIER (BOOSTER) AIR-AIR PRESSURE MULTIPLIER (BOOSTER) The air-air pressure multiplier, or booster, is an automatic device that compresses air to give an outlet pressure that is double the inlet pressure. It is normally

More information

ball valves Flomite 71 Series 2-way Integral Panel Mount Ball Valves

ball valves Flomite 71 Series 2-way Integral Panel Mount Ball Valves 2-way Integral Panel Mount Ball Valves Used for quick on-off service with a visual indication of flow, HOKE s 2-way ball valves offer orifice sizes up to 0.25 (6.4mm). Flomite valves feature a floating

More information

Stanadyne Fuel Manager Diesel Fuel Filter/Water Separator System. User s Guide

Stanadyne Fuel Manager Diesel Fuel Filter/Water Separator System. User s Guide Stanadyne Fuel Manager Diesel Fuel Filter/Water Separator System. User s Guide Brochure 99795, updated August 2002 1. Introduction Stanadyne has been making diesel fuel filters for over 30 years. Stanadyne

More information

Assisted lift operated 2/2-way solenoid valves Type EV250B

Assisted lift operated 2/2-way solenoid valves Type EV250B MAKING MODERN LIVING POSSIBLE Data sheet Assisted lift operated 2/2-way solenoid valves Type EV250B EV250B with assisted lift can operate from zero and up to 10 bar differential pressure. This 2/2-way

More information

Flow Sensors. Convenient, Reliable and Economical Flow Measurement. THORNTON Leading Pure Water Analytics

Flow Sensors. Convenient, Reliable and Economical Flow Measurement. THORNTON Leading Pure Water Analytics THORTO Leading Pure Water nalytics Economical Paddlewheel Hi-Purity PF Ultrasonic Vortex Insertion-type Vortex Convenient, Reliable and Economical Flow Measurement Paddlewheel Reliable and Economical Inline

More information

OEM Pressure Transmitters for heavy-duty applications, Type MBS 1200 and MBS 1250

OEM Pressure Transmitters for heavy-duty applications, Type MBS 1200 and MBS 1250 MAKING MODERN LIVING POSSIBLE Data sheet OEM Pressure Transmitters for heavy-duty applications, Type MBS 1200 and MBS 1250 The compact OEM pressure transmitter programme is designed for use in severe hydraulic

More information

Vickers. Check Valves. Check Valves. Inline, right angle, manifold mounted, and pilot operated designs. Released 9/93

Vickers. Check Valves. Check Valves. Inline, right angle, manifold mounted, and pilot operated designs. Released 9/93 Vickers Check Valves Check Valves Inline, right angle, manifold mounted, and pilot operated designs Released 9/93 645 Introduction Vickers inline, right-angle, and manifold mounted check valves are direct

More information

DXPE*J 85 320/215 ED. DIRECtIONAL CONtROL VALVE PILOt OPERAtED, WItH OBE AND FEEDBACK. Q max (see performance table) SERIES 30

DXPE*J 85 320/215 ED. DIRECtIONAL CONtROL VALVE PILOt OPERAtED, WItH OBE AND FEEDBACK. Q max (see performance table) SERIES 30 85 320/215 ED DXPE*J DIRECtIONAL CONtROL VALVE PILOt OPERAtED, WItH OBE AND FEEDBACK SUBPLAtE MOUNtINg DXPE5J CEtOP P05 DXPE5RJ ISO 4401-05 (CETOP R05) DXPE7J ISO 4401-07 (CETOP 07) DXPE8J ISO 4401-08

More information

VP23, 3-way proportional pressure control valves Seat valve with μp-driven pressure control

VP23, 3-way proportional pressure control valves Seat valve with μp-driven pressure control VP, -way proportional pressure control valves > > Port size: G/... G/ > > All-digital control electronics > > Variable pressure control > > Optional actuation via fieldbus (separate datasheet on request)

More information

Ball valve C 16 valve ball completely moulded in place, extremely low clearance volume, high k v value

Ball valve C 16 valve ball completely moulded in place, extremely low clearance volume, high k v value Ball valve C valve ball completely moulded in place, extremely low clearance volume, high k v value Advantage maximum safety due to valve ball completely moulded in place - ball and ball seat cannot be

More information

Introduction to Filtration

Introduction to Filtration Introduction to Filtration DEFINITION OF FILTRATION The process by which solid particles are separated from a fluid by passing the fluid through a permeable material that will not let the solid particles

More information

Parts Manual. TWIN 2 & 3 Parts & Accessories F210846R01. Your efficiency is our Challenge!

Parts Manual. TWIN 2 & 3 Parts & Accessories F210846R01. Your efficiency is our Challenge! Parts Manual TWIN 2 & 3 Parts & Accessories F210846R01 Your efficiency is our Challenge! All rights reserved. No part of this manual may be copied and/or published by means of printing, photocopying, microfilm

More information

6 Crankcase Ventilation

6 Crankcase Ventilation 6 Crankcase Ventilation Introduction... 6-3 Crankcase Ventilation Manager (CVM)... 6-5 Introduction... 6-6 CVM280B..................................... 6-7 CVM280T... 6-10 CVM424B....................................

More information

Product Datasheet. icountlaser CM20. Portable Particle Counter. ETLConMon. Description

Product Datasheet. icountlaser CM20. Portable Particle Counter. ETLConMon. Description icountlaser CM20 Portable Particle Counter Product Datasheet Description A 2-minute contamination test procedure: A portable particle counter designed to be used in the field. icountlcm20 is a proven answer

More information

FUEL SYSTEMS OUR PARTS PUT YOU IN THE PASSING LANE. Protect your fuel system. velvac.com

FUEL SYSTEMS OUR PARTS PUT YOU IN THE PASSING LANE. Protect your fuel system. velvac.com OUR PARTS PUT YOU IN THE PASSING LANE FUEL SYSTEMS Protect your fuel system. Velvac offers a wide range of locking fuel caps and anti-siphon tubes to keep unlawful occurances at bay. With OEM approved

More information

2/2 and 3/2 Way Size 6 Seat Valves

2/2 and 3/2 Way Size 6 Seat Valves 2/2 and 3/2 Way Size 6 Seat Valves Directly operated Interface and subplate dimensions according to DIN 24340 and ISO Line connection port size G 3/8" Cartridge design PN [p max. ] = 315 bar 7501856.06.12.08

More information

Sporlan V-Series Ruby Seat Solenoid Valves

Sporlan V-Series Ruby Seat Solenoid Valves aerospace climate control electromechanical filtration fluid & gas handling hydraulics pneumatics process control sealing & shielding Sporlan V-Series Ruby Seat Solenoid Valves RACE Catalogue 30-10-8 UK,

More information

Digital inductive conductivity transmitter

Digital inductive conductivity transmitter Digital inductive conductivity transmitter Optimal solution for conductivity measurements in difficult fluids (polluted, dirty,...) PEEK/PPA version for CIP applications Large range of process connections

More information

Fluid. Flu. Fluid Fluid. uid Power d Power P. Fluid Power P. Fluid Power. Fluid Power Power. d Power. Directional Cetop Valves DCV 03.

Fluid. Flu. Fluid Fluid. uid Power d Power P. Fluid Power P. Fluid Power. Fluid Power Power. d Power. Directional Cetop Valves DCV 03. Catalogue Directional Cetop Valves DCV 03 Power Flu uid Power d Power P wer Power Power Power Power Power d Power Power Power ower Power Power wer Power Power P Power Power Powe d Power Power Power Power

More information

Tyco PremiAir Pneumatic Actuators

Tyco PremiAir Pneumatic Actuators A comprehensive range of pneumatic actuators, conforming to EN ISO 5211, providing compact, reliable and economical powered operation for all types of quarter turn valves. Features Mounting to valve either

More information

Pressure reducing valve, direct operated, Type ZDR 6 D

Pressure reducing valve, direct operated, Type ZDR 6 D RE 26 57/2.3 Replaces:.2 Pressure reducing valve, direct operated, ype ZDR 6 D Nominal size 6 Series 4X aximum operating pressure 2 bar aximum flow 5 L/min K 4279/ ype ZDR 6 DP2 4X/ Y Overview of contents

More information

Pressure calibration equipment

Pressure calibration equipment Pressure calibration equipment Pressure calibration evolution 1925 Westertoren in Amsterdam 30 meter mercury column (±40 bar) 1950 comparison test pump 21 st century Stiko gas driven differential deadweight

More information

Parts. Ultra 395/495/595t Ultra Max II 490/495/595t 309675V 120 VAC. 3300 psi (228 bar, 22.8 MPa) Maximum Working Pressure.

Parts. Ultra 395/495/595t Ultra Max II 490/495/595t 309675V 120 VAC. 3300 psi (228 bar, 22.8 MPa) Maximum Working Pressure. Parts Ultra 395/495/595t Ultra Max II 490/495/595t 309675V EN 3300 psi (228 bar, 22.8 MPa) Maximum Working Pressure 0 VAC Type Stand Series Lo-boy Series Hi-boy Series Ultra 395t 2339 B 233961 B 233962

More information

Flow Control Valve. 1 Descriptions. 2 Symbols. Series SRCB.. 1.1 Generals. 1.2 Application examples. 2.2 3-way flow control. 2.1 2-way flow control

Flow Control Valve. 1 Descriptions. 2 Symbols. Series SRCB.. 1.1 Generals. 1.2 Application examples. 2.2 3-way flow control. 2.1 2-way flow control Flow Control Valve Series SRCB.. plug-in solenoid for easy coil change flow rates are unaffected by temperature change or when the higher load pressure alternates between the outlet ports energy - optimised

More information

Plastic tube flowmeters Series PT/PS

Plastic tube flowmeters Series PT/PS Plastic tube flowmeters Variable area flowmeter for liquids and gases Low cost, excellent readability and light weight Simple installation (flanged, threaded or socket ends for solvent or fusion welding

More information

Eurovacuum EV Series. Single Stage Oil Sealed Rotary Vane Pump

Eurovacuum EV Series. Single Stage Oil Sealed Rotary Vane Pump Eurovacuum EV Series Single Stage Oil Sealed Rotary Vane Pump Eurovacuum EV Series Single Stage Oil Sealed Rotary Vane Pumps Eurovacuum Company is offering its various products to meet industrial vacuum

More information

MVX-Series Diesel Engine Air Shut Down Valves

MVX-Series Diesel Engine Air Shut Down Valves MVX-Series Diesel Engine Air Shut Down Valves (Cable operated closure/integral reset lever types) Selection, Application and Maintenance SPECIAL VALVE MVX-304 This is a special version of valve type MVX-303

More information