12CS Series. Coreless Spin-on Filter Max. 75 l/min - 35 bar. Environmentally friendly alternative for spin-on filtration.

Size: px
Start display at page:

Download "12CS Series. Coreless Spin-on Filter Max. 75 l/min - 35 bar. Environmentally friendly alternative for spin-on filtration."

Transcription

1 2CS Series Coreless Spin-on Filter Max. 7 l/min - 3 bar Environmentally friendly alternative for spin-on filtration Lightweight, non-metallic element that can be incinerated The 2CS Series features a Parker, replaceable coreless Ecoglass lll element in a re-usable bowl for easy used element removal and disposal. Maximum pressure 3 bar and the Ecoglass element offers a low environmental impact in landfills. Contact Information: European Product Information Centre Freephone: (from AT, BE, CH, CZ, DE, EE, ES, FI, FR, IE, IT, PT, SE, SK, UK) filtrationinfo@parker.com Product Features: Ecoglass lll element. 4 FDHBUK. FDHBUK/2CS

2 Coreless Spin-on Filters 2CS Series The Smart Alternative to Spin-on Cans! Features: Parker engineers have developed an innovative alternative to the age old spin-on style can. This new design provides all of the benefits of high efficiency, long life Ecoglass III filtration, without the environmental impact. The new environmentally-friendly 2CS hydraulic filters feature a reuseable bowl and a quality filter element constructed primarily of nylon and fiberglass. The element core is permanently attached as part of the filter bowl. When replaced, the element reduces costs, eliminates hot drain requirements, can be easily incinerated, and is better-suited for most landfills. The 3 bar filter is rated up to 22 l/min, with premium Ecoglass III elements as standard offerings. The element design also prevents filter operation if the proper element is not in place. Applications: Mobile Ag Mobile Construction Material Handlers Aerial Lifts Pilot lines Charge pump hydrostatic drives Industrial power units Machine tools Feature Advantage Benefit in landfills. FDHBUK/2CS FDHBUK.

3 Specifications Pressure Ratings: Maximum Allowable Operating Pressure (MAOP): 3 bar ( psi) Fatigue: 27.6 bar (4 psi),, cycles: 27.6 bar Design Safety Factor: 2.: Operating Temperatures: Buna: -4ºC to 7ºC Element Collapse Rating:.3 bar ( psid) Element Condition Indicators: For predictive maintenance, 3 types of indicator are available: An electrical analogue or switch type indicator or a battery operated visual LED indicator. Materials: Head: die cast aluminium Bypass valve: nylon with steel spring Filter element: fibreglass and polyester with nylon endcaps Bowl: steel Permanent core: steel Weights (approximate): 2CS kg (3lbs.) 2CS-2 OUTLET 4 MOUNTING HOLES 34.9 mm 7. mm 34.9 mm INLET 7. mm 94.7 mm 47.4 mm LEFT SIDE (IF USED) 23.6 mm (IF USED) OUTLET INLET OUTLET INLET 284.7±. mm 4-47 Nm Drawings are for reference only. Contact factory for current version. 2.4 mm MINIMUM ELEMENT 26.9 mm Port Option S2 Port Thread -/6-2 UN-2B Mounting Thread Configuration 3/8 x 6 x /8 N2 3/4-4 NPTF- 3/8 x 6 x /8 G2 G3/4 BSPP 3/8 x 6 x /8 6 FDHBUK. FDHBUK/2CS

4 Coreless Spin-on Filters 2CS Series 2CS-2 Performance Beta Rating Efficiency Efficiency % PSID Capacity BAR 2Q Q Q Q Q Q 2Q Q Micron Size (c) Capacity grams LPM Flow vs Pressure Loss LPM cSt. 2 2 SUS 3cSt Empty Housing. PSID 2Q Q Q 2Q.. BAR PSID 3/4 Nominal Port Size.. BAR GPM GPM. 7 FDHBUK/2CS FDHBUK.

5 Coreless Spin-on Filters 2CS Series Service Instructions 2CS Filter Service Filter element should be replaced as indicated by filter indicator gauge,or at specified service intervals recommended by the OEM. Replacement element procedure A. Shut down system and release pressure in the filter line. B. Loosen bowl and remove rotating counter clockwise. C. Remove dirty element from filter head and discard. D. Lubricate element seals on clean element and install on filter head element locator. E. Install reuseable bowl onto element and filter head. Parts List Head 2 Bypass 3 Element 4 Bowl Indicators (on-off) Element Condition Indicators. Analog Elctrical - Supply voltage: 4. to. VDC - Main output current: ma - Output voltage: Ratiometric (see graph) - Approvals: CE, IP68 - Connector: 2 wire leads, 8 Gauge Yellow (analog out) Black (OV) Red (supply + V) VOLTS. V 4. V Switch or Analog Sensor 6. Switch (Reed swithc - On/Off - Connector: 2 wire leads, 8 Gauge - Yellow (NC), black (NO), Red (C) - Maximum switching voltage: 3V (DC/AC) - Maximum switching current.2a - Maximum carry current:.a - Approvals: CE, IP68 7. Visual Indicator (Red - LED) - Push to test - Battery operated - Visual LED (red = change element) Visual Indicator 8 FDHBUK. FDHBUK/2CS

6 Coreless Spin-on Filters 2CS Series How To Order 2CS 2 QE B P G S2 Description Coreless Spin-On, 7 l/min nominal K Description ( PSID) Description Description Double Ecoglass III,2µm Ecoglass III,µm Ecoglass III,µm Ecoglass III,2µm Description SAE-2 integral threads* 3/4" NPT integral threads G¾" BSPP (ISO 22) integral threads Description No options Description (NBR) Description None Replacement Elements (Ecoglass) 2QE QE QE 2QE 9476Q 94764Q 94763Q 94762Q 9 FDHBUK/2CS FDHBUK.

7 /4/8CN Series Medium Pressure Filters Max. 6 I/min - 7 bar Premium performance for medium pressure applications FEATURING An economical multipurpose filter solution aluminium head and spin-on bowl and can be specified with Microglass lll or Ecoglass lll filter media. Maximum pressure 7 bar. Maximum flow 6 l/min. Excellent performance value from a globally proven, reliable medium pressure filter. Contact Information: European Product Information Centre Freephone: (from AT, BE, CH, CZ, DE, EE, ES, FI, FR, IE, IT, PT, SE, SK, UK) filtrationinfo@parker.com Product Features: FDHBUK. FDHBUK//4/8CN

8 /4/8CN Series Medium Pressure Filters Features & Benefits Features 6 bar fatigue rating (eight times that of a spin-on) Diametral (side) seal between head and bowl Dust seal 4CN-2 meets automotive HF3 standard CN meets automotive HF2 standard Cast aluminium head elements Complete performance data disclosure available Coreless Ecoglass III replacement elements Advantages operating conditions Can be utilised in applications where high pressure filters may have been only option Proven reliability in cyclic applications Prevents contamination from building up on bowl/head threads Low profile, lightweight and durable Multi-layered design produced high capacity and efficiency Wire support reduces pleat bunching, keeps performance consistent compare format Check element condition at a glance No metal content in element Easy compaction of used elements Benefits filter failures No downtime, no leaks Performs with real world service Easier service, eliminates thread galling Satisfies specifications without need for further testing and/or approval Less weight, smaller envelop and cleaner appearance Great performance value No hidden deficiencies Easy selection of proper filtration Optimise element life, prevent bypassing Matches your system electrical connections Environmentally friendly disposal by incineration Lower element replacement costs Lower disposal cost Typical Applications Compressor lube oil Off-line filter loops Hydrostatic drive charge pumps Pilot lines for servo controls Injection moulding The Parker Filtration /4/8CN Series Medium Pressure Filters. This partial list of applications for Parker CN Series Filters has a common factor, the need for an economical, medium pressure range filter with excellent fatigue pressure ratings. Prior to the availability of the CN filter, applications such as those listed were restricted by limitations of a spin-on can, or forced into the higher-cost range of high pressure filters. The CN Series fills this gap and is now available with environmentally friendly Ecoglass III elements. FDHBUK//4/8CN FDHBUK.

9 Specification Pressure ratings: Connections: Several threaded port options available, flange faced ports available on 8CN. Connection style Model CN 4CN 8CN BSPF(G), 3 /4 /4, /2 /2, 2 ISO 649 M27 M33 M42, M48 Metric 3-M 2 Filter housing: Head material aluminium. Seal material: or fluoroelastomer. Operating temperature range: Bypass valve & indicator settings: Table following gives bypass valve and corresponding indicator setting. Bypass Indicator.7 bar.2 bar 2. bar Filter element: Degree of filtration: Determined by Multipass-test according to ISO Flow fatigue characteristics: Filter media is supported so that the optimal fatigue life is achieved (ISO 3724). Microglass III (available by request) Supported with epoxy coated metal wire mesh, end cap material reinforced composite and metal inner core. Collapse rating 2 bar (ISO 294). Ecoglass III Supported with plastic net, end cap material reinforced composite. No metal parts. Collapse rating bar (ISO 294). Filter element can only be used together with bowl including Eco-adaptor. Par-Gel: Water removal media absorbent copolymer laminate media with ability to remove free water from mineral based and synthetic fluids available for 4CN and 8CN. Indicator options: - visual M3. - electrical T. - electronic F(PNP). - electronic F2(NPN). For indicator details see catalogue section 6. Weights (kg): Model CN..6 4CN CN Fluid compatibility: Suitable for use with mineral and vegetable oils, and some synthetic oils. For other fluids, please consult Parker Filtration. CN H I N 4CN H J N 8CN H J N F G L K F G L K G L K F J I I M D M D M D C C C B P B P B P Element removal clearance 6mm (2. ) 2.4 (.) Nominal Hex E Drain plug Element removal clearance 6mm (2. ) 2.4 (.) Nominal Hex E Drain plug Element removal clearance 6mm (2. ) 2.4 (.) Nominal Hex E Drain plug Dimensions in mm (inch) Model A B C D E F G H I J K L M* N P CN 4CN 8CN 6.6 (6.7) 7.8 (6.73) 28.9 (.6) 2.7 (9.87) (.33) 4.6 (.8) 46. (.83) 62. (2.44) 77.7 (3.6) 2.4 (.9) 32.6 (.28) 49. (.9) 7. (2.8) 7.2 (4.22) 24.8 (4.9) 8.9 (3.38) 27. (.) 8.7 (6.2) 73.2 (2.88). (4.37) 82.6 (3.2) 82.6 (3.2) 2.9 (4.8).4 (.96) 38. (.) 62. (2.44).6 (4.) 22.9 (.9) 3.8 (.2) 4. (.62) 42.9 (.69) 8.8 (2.32) 79.4 (3.2) 36.6 (.44) 6.2 (2.37) 4.3 (.63) xM6-.x7.9 deep 4xM8-.2x3 deep 4xM8-.2x6 deep 2-27 Nm 7-68 Nm 8-9 Nm 2 FDHBUK. FDHBUK//4/8CN

10 /4/8CN Series Medium Pressure Filters 8CN Flange Face Details (SAE 2 3-M) Flange face mounting holes M2-.7 x 22 deep Pressure Drop Curves With.7 bar bypass the recommended initial pressure drop is max. bar. With bypass the recommended initial pressure drop is max. bar. The total p = housing pe x working viscosity/3). CN- Elements CN Empty Housing QE QE QE QE /4 Nominal Port Size Nominal Port Size 8 CN-2 Elements QE 2.. QE QE 2QE FDHBUK//4/8CN FDHBUK.

11 Pressure Drop Curves 4CN- Elements 4CN Empty Housing QE QE. QE. 2QE 2 2 p (bar) Nominal Port Size. /4 Nominal Port Size. /2 Nominal Port Size CN-2 Elements QE 2. QE. QE. 2QE CN- Elements 8CN Empty Housing QE QE QE. 2QE /2 Nominal Port Size 2 Nominal Port Size CN-2 Elements QE QE. QE 2QE FDHBUK. FDHBUK//4/8CN

12 /4/8CN Series Medium Pressure Filters Element Service C. Drain the filter bowl if drain port option is provided. D. Loosen and remove bowl. twisting motion and discard. F. Check bowl o-ring and anti-extrusion ring for damage and replace if necessary. G. Lubricate element o-ring with system fluid and place on post in filter head. H. Install bowl by rotating counter clockwise and tighten CN 2-27 Nm (-2ft. lbs) 4CN 7-68 Nm (42-ft. lbs) 8CN 8-9 Nm (6-7ft. lbs) I. Confirm there are no leaks after powering the system. 3 2 CN Filters Parts List Index Description Head Indicators Bypass valve.7 bar assembly assembly Element (see replacement element part numbers) Bowl Single length with drain Single length with reusable core and drain Single length without drain Double length with drain Double length with reusable core and drain Double length without drain Bowl and dust seal Drain plug: SAE FDHBUK//4/8CN FDHBUK.

13 Ordering Information Standard products table Part numbers CNQEVTKG64 CNQEVM3KG64 CN2QEVTKG64 CN2QEVM3KG64 CN2QEVTKG64 CN2QEVM3KG64 CN22QEVTKG64 CN22QEVM3KG64 4CNQEVTKG244 4CNQEVM3KG244 4CNQEVTKG244 4CNQEVM3KG244 4CN2QEVTKG244 4CN2QEVM3KG244 4CN2QEVTKG244 4CN2QEVM3KG244 4CN2QEVTKG244 4CN2QEVM3KG244 4CN22QEVTKG244 4CN22QEVM3KG244 8CNQEVTKG324 8CNQEVM3KG324 8CN2QEVTKG324 8CN2QEVM3KG324 8CN2QEVTKG324 8CN2QEVM3KG324 8CN22QEVTKG324 8CN22QEVM3KG324 Supersedes Flow (l/min) Model number CN CN CN CN CN CN CN CN 4CN 4CN 4CN 4CN 4CN 4CN 4CN 4CN 4CN 4CN 4CN 4CN 8CN 8CN 8CN 8CN 8CN 8CN 8CN 8CN Element length Media rating (µ) Seals Indicator Bypass settings Ports G" G" G" G" G" G" G" G" G2" G2" G2" G2" G2" G2" G2" G2" Replacement elements 9367Q 9367Q 9367Q 9367Q 93674Q 93674Q 9367Q 9367Q 93677Q 93677Q 93678Q 93678Q 93679Q 93679Q 9367Q 9367Q 9366Q 9366Q 93672Q 93672Q 93662Q 93662Q 9367Q 9367Q 93678Q 93678Q 93679Q 93679Q Part Number S4449 S44 S4447 S4448 S448 S449 CN Series Seal Kits Description 6 FDHBUK. FDHBUK//4/8CN

14 /4/8CN Series Medium Pressure Filters Ordering Information (cont.) Product Configurator Box 4CN Box Model CN- CN-2 4CN- 4CN-2 8CN- 8CN-2 Box 2 2 Model Box 3 Element media Ecoglass III element Box 3 QE Box 4 V Ecoglass III elements ( seals) 2QE Q 93672Q 93676Q 9367Q 93673Q 93676Q QE Q 93673Q 93677Q 9367Q 93674Q 93677Q CN 4CN 8CN QE 9367Q 93674Q 93678Q 9366Q 93662Q 93678Q Conversion bowl assembly (to retrofit existing CN filter housings to use coreless elements) CN- coreless element bowl assembly CN-2 coreless element bowl assembly CN- coreless element bowl assembly CN-2 coreless element bowl assembly CN- coreless element bowl assembly CN-2 coreless element bowl assembly Box 2 Length 2QE 9367Q 9367Q 93679Q 93672Q 9367Q 93679Q Box M3 Filter type Model CN- CN-2 4CN- 4CN-2 8CN- 8CN-2 2 Box Box 6 No indicator port indicator Electronic 4 LED, PNP, N.O. Electronic 4 LED, NPN, N.O. Electronic 4 LED, PNP, N.C. Electronic 4 LED, NPN, N.C. Box 8 Indicator Options Options Standard drain port on bowl Degree of filtration Glass fibre Media code 2QE QE QE N M3 T P F F2 F3 F4 4 Bypass valve.7 bar EX Filter assemblies with EX code will be supplied with a dedicated name plate. Elements with nitrile seals 2Q 2QE Box 6 K Bypass valve Indicator.2 bar 2. bar Q Q Box 7 G24 2Q Model CN- CN-2 4CN- 4CN-2 8CN- 8CN-2 Box 8 4 Highlights Key (Denotes part number availability) Water Removal WR G K When filter includes a bypass valve but not an indicator, code denotes bypass setting. Item is standard Item is standard green option Item is semi standard Item is non standard Box 4 Seal type Seal material Box 7 Elements with seals 2Q Q V B Filter connection Ports 3 /4 Thread G Thread M27, ISO649 /4 Thread G /2 Thread M33, ISO649 /2 Thread G2 Thread M42, ISO649 Thread M48, ISO649 Q 2Q G2 G6 S2 S6 M27 G2 G24 S6 S24 M33 G24 G32 S24 S32 M42 M48 R32 WR ßx(c)=2.% 6 Degree of filtration Average filtration beta ratio ß (ISO 6889) / particle size µm [c] ßx(c)= ßx(c)=7 ßx(c)= ßx(c)=2 ßx(c)= % efficiency, based on the above beta ratio (ßx) 9.% % % % 6 2 Please note the bolded options reflect standard options with a reduced lead-time of (4) weeks or less. Consult Parker Filtration on all other lead-time options. 99.9% Metal free Ecoglass III 2QE QE QE 2QE Nominal flow (l/min) for filter assembly at viscosity 3cSt Housing, port size CN-, G CN-2, G 4CN-, G /2 4CN-2, G /2 8CN-, G2 8CN-2, G2 2QE QE QE QE * s are available under various registered trademarks, trademark of 3M) 7 FDHBUK//4/8CN FDHBUK.

15 4M/4 Eco Series Medium Pressure Filters Max 26 l/min - 4 bar environments FEATURING Approved for engine rooms and mines head and steel bowl design and can be specified with Microglass lll or Ecoglass lll filter media. Maximum pressure 4 bar. Maximum flow 26 l/min. Lower element replacement costs and lower disposal costs Contact Information: European Product Information Centre Freephone: (from AT, BE, CH, CZ, DE, EE, ES, FI, FR, IE, IT, PT, SE, SK, UK) filtrationinfo@parker.com Product Features: lower pressures. 8 FDHBUK. FDHBUK/4M/4 Eco

16 4M/4 Eco Series Medium Pressure Filters Features & Benefits Features Cast iron head, steel bowl replacement elements indicators available Test points in the filter head Coreless Ecoglass III replacement elements Advantages Can be used in applications where aluminium is not allowed Multi-layered design produced high capacity and efficiency Wire support reduces pleat bunching, keeps performance consistent Check element condition at glance Pressure measurement and p possible No metal content in element Easy compaction of used elements Eco adaptors available Benefits Great performance value element life element life Optimise element life, prevent bypassing Matches your system electrical connections Environmentally friendly disposal by incineration Lower element replacement costs Lower disposal costs already installed Typical Applications Industrial power units Mobile construction The Parker Filtration 4M/4 Eco Series Medium Pressure Filters. The 4M/4 Eco Series of medium pressure filters offer an ideal solution to the problem of protecting system components at lower pressures. The robust filter housing of the 4M allows the product to be applied in harsh environments. Filter bowl is designed for rapid element replacement. due to the reusable element core. 9 FDHBUK/4M/4 FDHBUK. Eco

17 Specification Pressure ratings: Maximum allowable operating pressure 4 bar. 6 pulses -4 bar. Connections: Threads G, G /4 /2 3-M. Filter housing: Head material cast iron (GSI). Bowl material steel. Seal material: or. Operating temperature range: Bypass valve: Opening pressure. Filter element: Degree of filtration: Determined by Multipass-test according to ISO Flow fatigue characteristics: Filter media is supported so that the optimal fatigue life is achieved (ISO 3724). Microglass III: Supported with epoxy coated metal wire mesh, end cap material reinforced composite and metal inner core. Collapse rating 2 bar (ISO 294). Ecoglass III: Supported with plastic net, end cap material reinforced composite. No metal parts. Collapse rating bar (ISO 294). Indicator options: - visual M3. - electrical T. - electronic F(PNP). - electronic F2(NPN). For indicator details see catalogue section 6. Fluid compatibility: Suitable for use with mineral and vegetable oils, and some synthetic oils. For other fluids, please consult Parker Filtration. Installation Details Plug M2x. Type A B C Weight (kg) D Length 3 6 (4.7) 28 (8.2) 329 (3.) 237 (9.33) 92 (7.6) 33 (3.) 28 (.22) 4 (7.72) 4 (.94) G, G /4, G /2, /2 3-M D OUT IN D Length (6.8) (2.6) (9.9) (2.7) 4 pcs M2 depth (.4) 38 (.) M depth 2 C B mm (inches) 32 (.2) 7 (2.7) 66 (2.6) min (2.) 39 (.3) 2 8 (2.28) FDHBUK. FDHBUK/4M/4 Eco

18 4M/4 Eco Series Medium Pressure Filters Pressure Drop Curves The recommended level of the initial pressure drop is max. bar. The total p = housing pe x working viscosity/3). 4M Series Empty Housing G6 G2 G24 R M- Element with Microglass III 4M-2 Element with Microglass III Q.2 Q Q 2Q Q Q Q 2Q M-3 Element with Microglass III 4M-4 Element with Microglass III Q Q 2Q Q Q Q Q 2Q FDHBUK/4M/4 FDHBUK. Eco

19 4M- Element with Ecoglass III 4M-2 Element with Ecoglass III QE QE 2QE QE QE QE QE QE M-3 Element with Ecoglass III 4M-4 Elements with Ecoglass III QE QE QE QE QE QE QE QE Ordering Information Standard products table Product numbers 4MQBPKG6 4M2QBPKG6 4MQEBPKG6 4M2QEBPKG6 4M2QBPKG2 4M22QBPKG2 4M2QEBPKG2 4M22QEBPKG2 4M3QBPKG24 4M32QBPKG24 4M3QEBPKG24 4M32QEBPKG24 Supersedes Flow (l/min) Model number 4M 4M 4M 4M 4M 4M 4M 4M 4M 4M 4M 4M Element length Length 3 Length 3 Length 3 Length 3 Media rating (µ) Seals Indicator Bypass settings Ports G" G" G" G" G /4" G /4" G /4" G /4" Replacement elements Q Q Q Q Q Q Q Q 93897Q 93897Q Q Q Supersedes Part Number M Series Seal Kits Description 22 FDHBUK. FDHBUK/4M/4 Eco

20 4M/4 Eco Series Medium Pressure Filters Ordering Information (cont.) Product configurator Box Box 2 4M 2 Box 3 Q Box 4 B Box M3 Box 6 K Box 7 G2 Box 8 Box Model Medium pressure filter, T-port 4M Highlights Key (Denotes part number availability) Item is standard Item is standard green option Item is semi standard Item is non standard Box 2 Length Length 3 Length 4 Box 4 Filter type Seal type Seal material Box 7 Connections Thread G Thread G /4 Thread G /2 /2" 3-M B G6 G2 G24 Box 3 S = standard option x = non-standard, ask for availability Element media Microglass III element Ecoglass III element Box with steel plug indicator Electronic 4 LED, PNP, N.O. Electronic 4 LED, NPN, N.O. Electronic 4 LED, PNP, N.C. Electronic 4 LED, NPN, N.C. Filter connection S S x x S S S x Degree of filtration Glass fibre Media code 2Q 2QE Indicator Length 3 S S S x Q QE Length 4 x S S x P M3 T F F2 F3 F4 Q QE Box 8 Box 6 Bypass valve No bypass No bypass 2Q 2QE Bypass valve Indicator 2. bar 7. bar No indicator (P) Options Options Standard No bypass K N X When filter includes a bypass valve but not an indicator, code denotes bypass setting. 2 EX Filter assemblies with EX code will be supplied with a dedicated name plate. Media Replacement elements with nitrile seals 93896Q 93896Q Q Q Q Q Q Q Q 93896Q Q Q 93898Q 93898Q Q Q Length Q Q 93897Q 93897Q Q 93898Q Q Q Length Q Q Q 93897Q Q Q 93899Q 93899Q Nominal flow (I/min) at viscosity 3 cst - connection size Filter length Length 3 Length 4 Media G G ßx(c)=2.% 6 Degree of filtration Average filtration beta ratio ß (ISO 6889) / particle size µm [c] ßx(c)= ßx(c)=7 ßx(c)= ßx(c)=2 ßx(c)= % efficiency, based on the above beta ratio (ßx) 9.% % % % % Disposable Microglass III 2Q Q Q 2Q Metal free Ecoglass III QE 2QE 23 FDHBUK/4M/4 FDHBUK. Eco

15/40/80CN Series Medium Pressure Filters Max. 600 I/min - 70 bar

15/40/80CN Series Medium Pressure Filters Max. 600 I/min - 70 bar 1/4/8CN Series Max. 6 I/min - 7 bar Premium performance for medium pressure applications FEATURING An economical multipurpose filter solution The CN Series utilizes a cast aluminium head and spin-on bowl

More information

12CS Series Coreless Spin-on Filter Max. 75 l/min - 35 bar

12CS Series Coreless Spin-on Filter Max. 75 l/min - 35 bar 2CS Series Coreless Spin-on Filter Max. 7 l/min - 3 bar Environmentally friendly alternative for spin-on filtration Lightweight, non-metallic element that can be incinerated The 2CS Series features a Parker,

More information

15/40/80CN Series Medium Pressure Filters

15/40/80CN Series Medium Pressure Filters 1/4/8CN Series Medium Pressure Filters Max 32 l/min - 7 bar Global Filtration Technology 1/4/8CN Series TYPICAL APPLICATIONS Compressor Lube Oil Off-line Filter Loops Machine Tools (Automotive Standard)

More information

15/40/80CN Series Coreless Medium Pressure Filters

15/40/80CN Series Coreless Medium Pressure Filters //8CN Series Coreless Medium Pressure Filters //8CN Series Applications Compressor Lube Oil Off-line Filter Loops Machine Tools (Automotive Standard) Hydrostatic Drive Charge Pumps Mobile Equipment Pilot

More information

Eco130 Series. Medium Pressure Filters Max. 1400 l/min. 30 bar. Modular system for industrial applications. Applications: Contact Information:

Eco130 Series. Medium Pressure Filters Max. 1400 l/min. 30 bar. Modular system for industrial applications. Applications: Contact Information: Eco130 Series Medium Pressure Filters Max. 1400 l/min. 30 bar Modular system for industrial applications High flow return filters for industrial use on hydraulic or lubrication systems. High flow and pressure

More information

Eco130 Series. Medium Pressure Filters Max. 1400 l/min. 30 bar. Modular system for industrial applications. Applications: Contact Information:

Eco130 Series. Medium Pressure Filters Max. 1400 l/min. 30 bar. Modular system for industrial applications. Applications: Contact Information: Eco130 Series Medium Pressure Filters Max. 1400 l/min. 30 bar Modular system for industrial applications High flow return filters for industrial use on hydraulic or lubrication systems. High flow and pressure

More information

Coreless Spin-On Filters. 12AS/50AS Series

Coreless Spin-On Filters. 12AS/50AS Series Coreless Spin-On Filters 12AS/5AS Series Coreless Spin-on Filters 12AS/5AS Series The Smart Alternative to Spin-on Cans! Features: Parker engineers have developed an innovative alternative to the age old

More information

High Pressure Filters. 70/70 Eco Series. MAX 450 I/min -420 bar FEATURING. High pressure filters

High Pressure Filters. 70/70 Eco Series. MAX 450 I/min -420 bar FEATURING. High pressure filters 7/7 Eco eries MAX 5 I/min - bar FEATURING 5 High pressure filters 7/7 Eco eries Features &enefits Features Fatigue tested to full pressure rating everal head options and connection sizes everal bowl lengths

More information

BGAH Series. Medium Pressure Filters Max. 500 l/min. 25 bar. In-line solution for a straight pipeline. Applications: Contact Information:

BGAH Series. Medium Pressure Filters Max. 500 l/min. 25 bar. In-line solution for a straight pipeline. Applications: Contact Information: BGAH Series Medium Pressure Filters Max. 500 l/min. 25 bar In-line solution for a straight pipeline Pre-filtration by magnet column and a full-flow bypass with low hysteresis. Contamination-proof in-out

More information

HFS and HFD Series. High Flow Single and Duplex Filters Max. 11200 l/min. 10 bar. Heavy Duty Reliability. Applications: Contact Information:

HFS and HFD Series. High Flow Single and Duplex Filters Max. 11200 l/min. 10 bar. Heavy Duty Reliability. Applications: Contact Information: High Flow Single and Duplex Filters Max. 11200 l/min. 10 bar Heavy Duty Reliability New High Flow Single and Duplex Filters ensure reliability in industrial, marine, and power generation applications up

More information

PVS Series - Models 185, 600, 1200, 1800 and 2700

PVS Series - Models 185, 600, 1200, 1800 and 2700 PVS Series - Models 185, 600, 1200, 1800 and 2700 Reduce the catastrophic results of water contamination Eliminate water from the hydraulic system The PVS Series Portable Purification Systems, available

More information

NORMAN FILTER COMPANY PRODUCT OVERVIEW

NORMAN FILTER COMPANY PRODUCT OVERVIEW NORMAN FILTER COMPANY PRODUCT OVERVIEW LEADING THE WAY IN QUALITY FILTRATION WWW.NORMANFILTERS.COM FILTER ELEMENT INTERCHANGE Tee-Type Filter 4500, 14500, 34500, and 54500 Series Mini Tee-Type Filter 4100

More information

In-Tank Mounted Return Line Filters. IN-AGB Series. MAX 2400 I/min LEIF LEIF FILTER FEATURING AN INNOVATIVE GREEN. Low pressure filters

In-Tank Mounted Return Line Filters. IN-AGB Series. MAX 2400 I/min LEIF LEIF FILTER FEATURING AN INNOVATIVE GREEN. Low pressure filters MAX I/min AN INNOVATIVE GREEN FILTER FEATURING LEIF LEIF Low pressure filters Features & Benefits Features Filter integrated in tank LEIF elements Magnetic pre-filtration In-to-Out filtration igh level

More information

HOW THE CONTAMINATION IS MEASURED CONTAMINATION CLASSES ACCORDING TO ISO 4406:1999

HOW THE CONTAMINATION IS MEASURED CONTAMINATION CLASSES ACCORDING TO ISO 4406:1999 CONTAMINATION CONTROL in hydraulic systems in the hydraulic system is a very wide and complex matter; the following is just a short summary. Our Customer Service is at your disposal for any further information.

More information

OUT. The SF2 series suction filter are designed for reservoir side-wall applications. This completely new design of filter allows the filter

OUT. The SF2 series suction filter are designed for reservoir side-wall applications. This completely new design of filter allows the filter D e s c r i p t i o n 250 The SF2 series suction filter are designed for reservoir side-wall applications. This completely new design of filter allows the filter within the filter preventing oil loss from

More information

SMR Series Submicronic Removal Fluid Purifi cation Systems

SMR Series Submicronic Removal Fluid Purifi cation Systems SMR Series Submicronic Removal Fluid Purifi cation Systems 193 SMR Series Applications The SMR Series is the smart purification solution for fluid flow in the 2-10 GPM (8-38 LPM) range. The SMR contains

More information

The SF2 series are designed for reservoir side-wall mounting applications, suitable for flow rates to 850 l/min and filtration from 25 to 250 micron.

The SF2 series are designed for reservoir side-wall mounting applications, suitable for flow rates to 850 l/min and filtration from 25 to 250 micron. D e s c r i p t i o n 500 The SF2 series are designed for reservoir side-wall mounting applications, suitable for flow rates to 850 l/min and filtration from 25 to 250 micron. A major feature of these

More information

Hydraulic Filtration & Contamination Control Products. Catalogue: FDHB200UK January 2007

Hydraulic Filtration & Contamination Control Products. Catalogue: FDHB200UK January 2007 Hydraulic Filtration & Contamination Control Products Catalogue: FDHB2UK January 27 Consistent quality Technical innovation Premier customer service Hydraulic, Lubrication & Coolant Filtration High-performance

More information

Return line filters. Return line filters

Return line filters. Return line filters Return line filters Return line filters Index Technical data - 5 Filters series 6 Filters series --3 8 ccessories Spare parts Uni-ardan Italia S.p.. reserves the right to make technical changes to the

More information

Flow Control Valves. Note: Also see R04C3 on page DC1. Denotes New Winner s Circle Product Line. Catalog HY15-3502/US

Flow Control Valves. Note: Also see R04C3 on page DC1. Denotes New Winner s Circle Product Line. Catalog HY15-3502/US Catalog HY15-352/US Contents Control SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO. LPM/GPM BAR/PSI NEED VALVES J2A2... C8-2... Needle Valve, Cartridge Type...45/12... 42/6... 5-6 NVH81... C8-2... Needle

More information

New. absolute filter elements independently tested in the following Institutes: MPH-MPI 02050/7.99/USA 2 COVER INSERT

New. absolute filter elements independently tested in the following Institutes: MPH-MPI 02050/7.99/USA 2 COVER INSERT e s c r i p t i o n MPH and MPI series filters are designed for returnline applications and provide various installation applications. The filters are installed semiimmersed or totally immersed into a

More information

Check Valves Valve locator

Check Valves Valve locator Check Valves Valve locator Functional Symbol Flow Typical Model Cavity Rating Pressure Page Check valve, direct L/min (USgpm) bar (psi) FPR/4 Inline () 5 (5) - FPR/8 Inline (8) 5 (5) - FPR/ Inline 45 ()

More information

*Rated to 207 Bar/3000 PSI with Aluminum Body. Denotes New Winner s Circle Product Line. Catalog HY15-3502/US

*Rated to 207 Bar/3000 PSI with Aluminum Body. Denotes New Winner s Circle Product Line. Catalog HY15-3502/US Bodies & Contents SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO. LPM/GPM BAR/PSI STANDARD CHECKS D1A6... 2U... Valve Insert, Ball Type...145/38... 42/6... 5 D1B125... 2C... Valve Insert, Ball Type...

More information

PVS 185, 600, 1200, 1800, 2700 Series Portable Purification Systems

PVS 185, 600, 1200, 1800, 2700 Series Portable Purification Systems 185, 600, 1200, 1800, 2700 Series Portable Purification Systems FEATURING Global Filtration Technology PRINCIPLES OF OPERATION Contaminated oil is drawn into the Parker Portable Purification System by

More information

RPE3-04. Functional Description HA 4014 10/2010. Directional Control Valves Solenoid Operated. Replaces HA 4014 12/2007

RPE3-04. Functional Description HA 4014 10/2010. Directional Control Valves Solenoid Operated. Replaces HA 4014 12/2007 Directional Control Valves Solenoid Operated RPE3-04 Size D 04 (02) 320 bar (4600 PSI) 30 L/min(8.0 GPM) HA 4014 10/2010 Replaces HA 4014 12/2007 4/3-, 4/2- way directional control valves with solenoid

More information

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES BQ FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES Versatility, power, compactness and low running costs are the main characteristics of B&C vane pumps. All the components subject to wear are contained

More information

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES BQ FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES Versatility, power, compactness and low running costs are the main characteristics of B&C vane pumps. All the components subject to wear are contained

More information

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES BQ FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES Versatility, power, compactness and low running costs are the main characteristics of B&C vane pumps. All the components subject to wear are contained

More information

RMF TANDEM 900 OFF-LINE FILTER SYSTEMS

RMF TANDEM 900 OFF-LINE FILTER SYSTEMS RMF TANDEM 900 OFF-LINE FILTER SYSTEMS RMF Tandem 900 Off-line filter Systems can be applied to every imaginable industrial application where hydraulic or lubrication systems are present. An integrated

More information

Fluid. Flu. Fluid Fluid. uid Power d Power P. Fluid Power P. Fluid Power. Fluid Power Power. d Power. Directional Cetop Valves DCV 03.

Fluid. Flu. Fluid Fluid. uid Power d Power P. Fluid Power P. Fluid Power. Fluid Power Power. d Power. Directional Cetop Valves DCV 03. Catalogue Directional Cetop Valves DCV 03 Power Flu uid Power d Power P wer Power Power Power Power Power d Power Power Power ower Power Power wer Power Power P Power Power Powe d Power Power Power Power

More information

Vickers. Check Valves. Check Valves. Inline, right angle, manifold mounted, and pilot operated designs. Released 9/93

Vickers. Check Valves. Check Valves. Inline, right angle, manifold mounted, and pilot operated designs. Released 9/93 Vickers Check Valves Check Valves Inline, right angle, manifold mounted, and pilot operated designs Released 9/93 645 Introduction Vickers inline, right-angle, and manifold mounted check valves are direct

More information

Reusable contamination basket prevents loss of retained contaminants into the reservoir during element replacement.

Reusable contamination basket prevents loss of retained contaminants into the reservoir during element replacement. APPLICATION RETURN LINE FILTERS Series RF & RFD Pressures to 36 PSI Flows to 3 GPM HYDAC RF and RFD In-Tank Return Line Filters are designed for use on hydraulic power units, machine tools, plastics machinery,

More information

*Rated to 207 Bar/3000 PSI with Aluminum Body. Catalog HY15-3501/US SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO.

*Rated to 207 Bar/3000 PSI with Aluminum Body. Catalog HY15-3501/US SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO. Bodies & Contents SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO. /GPM BAR/PSI STANDARD CHECKS D1A6... 2U... Valve Insert, Ball Type...145/38... 42/6... 5 D1B125... 2C... Valve Insert, Ball Type... 5/132...

More information

Stanadyne Fuel Manager Diesel Fuel Filter/Water Separator System. User s Guide

Stanadyne Fuel Manager Diesel Fuel Filter/Water Separator System. User s Guide Stanadyne Fuel Manager Diesel Fuel Filter/Water Separator System. User s Guide Brochure 99795, updated August 2002 1. Introduction Stanadyne has been making diesel fuel filters for over 30 years. Stanadyne

More information

Sensors. Sensors. All Cylinders. Specifications. Features: Features Type REED HALL EFFECT NPN or PNP. Ø8mm - 125mm

Sensors. Sensors. All Cylinders. Specifications. Features: Features Type REED HALL EFFECT NPN or PNP. Ø8mm - 125mm Specifications Features Type REED HALL EFFECT NPN or PNP Applicable Series Configurations Construction Materials Body Mounting Bracket Cable Characteristics Operating Temperature Accuracy All Cylinders

More information

Series TMM Axial Piston Motor. Technical Information

Series TMM Axial Piston Motor. Technical Information Series TMM Axial Piston Motor Technical Information General Description GENERAL DESCRIPTION These motors are designed primarily to be combined with other products in closed circuit systems to transfer

More information

VARIABLE DISPLACEMENT AXIAL PISTON PUMPS. For truck applications

VARIABLE DISPLACEMENT AXIAL PISTON PUMPS. For truck applications VARIABLE DISPLACEMENT AXIAL PISTON PUMPS For truck applications TVP FEATURES Variable displacement axial piston pumps swash plate design ideally suited for open circuit truck applications. The compact

More information

2011 DC Electropumps Bull. Rotation Ø 15 6,45 3,5 5,7

2011 DC Electropumps Bull. Rotation Ø 15 6,45 3,5 5,7 Ø 5 ±. DC Electropumps Bull,5 Rotation,5 5,7 Email: sales@hydronit.com Fax B... Electro pumps Bull series MODEL CODE EPB,5 DC /S5 K, V** Electro Pump Bull series Gear pump displacement (cc/rev (see tables

More information

Hydraulic Flow Control Valves

Hydraulic Flow Control Valves Webtec Products Limited Hydraulic Flow Control Valves Quality Hydraulic Components from the Webtec Range CONTENTS DESCRIPTION PAGE No. ILFC Series Fixed Flow Pressure Compensated Control Valve 1 VFC Series

More information

HIGH PERFORMANCE FILTERS AND ELEMENTS

HIGH PERFORMANCE FILTERS AND ELEMENTS HIGH PERFORMANCE FILTERS AND ELEMENTS FILTRATION Fil*tra*tion (fil-tra-shen) n. The act or process of filtering. What exactly is filtration and why is it an integral part of today s industries? Simply

More information

Duplex Filters 40/160 LD 0003-0045 40/160 LDN 0040-0400. Industrial Filters Accumulators. Filters for inline installation for continuous operation

Duplex Filters 40/160 LD 0003-0045 40/160 LDN 0040-0400. Industrial Filters Accumulators. Filters for inline installation for continuous operation Industrial Filters Accumulators Duplex Filters 40/160 LD 0003-0045 40/160 LDN 0040-0400 Filters for inline installation for continuous operation With integrated pressure equalisation valve Optimised flow

More information

Piston Accumulators. SK Series. Accumulator Catalog. Piston Types. Description. Sealing Systems. End Cap. O-ring. Sealing System. Piston.

Piston Accumulators. SK Series. Accumulator Catalog. Piston Types. Description. Sealing Systems. End Cap. O-ring. Sealing System. Piston. SK Series Piston Types TYPE 2 pplication: Low-friction design for higher piston speeds, slow movements without stick-slip effect and high number of actuations (millions). ctual cycles achieved will vary

More information

MHT. Pressure Filters HIGH PRESSURE INLINE FILTER

MHT. Pressure Filters HIGH PRESSURE INLINE FILTER MHT Pressure Filters HIGH PEUE INLINE FILTE Pressure Filters MHT MHT 4 MPa ( bar) Port sizes: / / Flow rates: 0 l/min TEHNIAL DATA Max. working pressure: 4 MPa ( bar) Max. testing pressure: 6 MPa (60 bar)

More information

OEM Pressure Transmitters for heavy-duty applications, Type MBS 1200 and MBS 1250

OEM Pressure Transmitters for heavy-duty applications, Type MBS 1200 and MBS 1250 MAKING MODERN LIVING POSSIBLE Data sheet OEM Pressure Transmitters for heavy-duty applications, Type MBS 1200 and MBS 1250 The compact OEM pressure transmitter programme is designed for use in severe hydraulic

More information

Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm

Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm Electronic pressure measurement Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm WIKA data sheet PE 81.67 Applications Machine tools Hydraulics

More information

Catalog HY15-3501/US SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO. LPM/GPM BAR/PSI

Catalog HY15-3501/US SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO. LPM/GPM BAR/PSI Bodies & Contents SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO. LPM/GPM BAR/PSI KSWA3... SW-3... Ball sert Type...9./2.... 42/6... 3 K2A... 3Z... Poppet sert Type...38/1... 3/... 4 CS41B... C4-3...

More information

300 Series PA Pump and Cooler Assemblies

300 Series PA Pump and Cooler Assemblies Type 300 Series PA Sizes 300 thru 370 (Page 1 of 9) 300 Series PA Pump and Cooler Assemblies Pump and Cooler Assemblies with Air/Oil Heat Exchanger When compact gear drives require assistance to dissipate

More information

Cartridge Valves. Solenoid Valves. Vickers. Screw-in Cartridge Valves. Maximum Pressure 210 bar (3000 psi) Maximum Flow 227 l/min (60 USgpm)

Cartridge Valves. Solenoid Valves. Vickers. Screw-in Cartridge Valves. Maximum Pressure 210 bar (3000 psi) Maximum Flow 227 l/min (60 USgpm) Vickers Cartridge Valves Solenoid Valves Screw-in Cartridge Valves Maximum Pressure bar ( psi) Maximum Flow 7 l/min (6 USgpm) Rev /99 77 Introduction For over seventy years, Vickers has provided its customers

More information

Proportional relief valves type AGMZO-TERS, AERS two stage, with integral or remote pressure transducer, ISO 6264 size 10, 20 and 32

Proportional relief valves type AGMZO-TERS, AERS two stage, with integral or remote pressure transducer, ISO 6264 size 10, 20 and 32 www.atos.com Table F040-1/E Proportional relief valves type AGMZO-TERS, AERS two stage, with integral or remote pressure transducer, ISO 6264 size 10, 20 and 32 AGMZO are two stage poppet type proportional

More information

MONO BLOCK DIRECTIONAL CONTROL VALVE TS1120TSLB

MONO BLOCK DIRECTIONAL CONTROL VALVE TS1120TSLB MONO BLOCK DIRECTIONAL CONTROL VALVE TS112TSLB TS TS212TSTSJB P T TS312TSDTSTKJ TS112TSJB FEATURES: O RG PORTS to eliminate leakage. POWER BEYOND CAPABILITY to fit your multi valve circuits. BUILT ANTI-DROP

More information

The Par-Gel Filter Water Removal Filter Elements

The Par-Gel Filter Water Removal Filter Elements Stopping free water causing system damage Increases system efficiency and machine productivity The Par-Gel filter elements are an effective tool in controlling water related problems in hydraulic power

More information

Portable Purification Systems Models PVS 185, 600, 1200, 1800, 2700

Portable Purification Systems Models PVS 185, 600, 1200, 1800, 2700 Portable Purification Systems Models PVS 185, 600, 1200, 1800, 2700 www.comoso.com 190 800.696.6165 PVS Series Principles of Operation Contaminated oil is drawn into the Parker Portable Purification System

More information

Turbine Flow Sensor Series VTR

Turbine Flow Sensor Series VTR Turbine Flow Sensor Series VTR SIKA Turbine Flow Sensor Series VTR Extra robust, impressively precise SIKA s VTR turbine flow sensor allows you to determine precisely, dependably and easily the flow rates

More information

DXPE*J 85 320/215 ED. DIRECtIONAL CONtROL VALVE PILOt OPERAtED, WItH OBE AND FEEDBACK. Q max (see performance table) SERIES 30

DXPE*J 85 320/215 ED. DIRECtIONAL CONtROL VALVE PILOt OPERAtED, WItH OBE AND FEEDBACK. Q max (see performance table) SERIES 30 85 320/215 ED DXPE*J DIRECtIONAL CONtROL VALVE PILOt OPERAtED, WItH OBE AND FEEDBACK SUBPLAtE MOUNtINg DXPE5J CEtOP P05 DXPE5RJ ISO 4401-05 (CETOP R05) DXPE7J ISO 4401-07 (CETOP 07) DXPE8J ISO 4401-08

More information

Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS

Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS up to size 381; to PN 0.5; to T = 80 C 1. Description 1.1. General FSA fluid level gauges, FSK fluid level sensors and TS temperature

More information

SCP 012-130 ISO. Other advantages: SCP 012-130 ISO is a series of piston pumps with a fixed displacement for mobile and stationary hydraulics.

SCP 012-130 ISO. Other advantages: SCP 012-130 ISO is a series of piston pumps with a fixed displacement for mobile and stationary hydraulics. SCP 012-130 ISO is a series of piston pumps with a fixed displacement for mobile and stationary hydraulics. SCP 012-130 ISO covers the entire displacement range 12-130 cmᶟ rev. at a maximum pressure of

More information

USA Headquarters. Dynex/Rivett Inc. 770 Capitol Drive Pewaukee, WI 53072 U.S.A. Tel: 262-691-2222 FAX: 262-691-0312 E-mail: sales@dynexhydraulics.

USA Headquarters. Dynex/Rivett Inc. 770 Capitol Drive Pewaukee, WI 53072 U.S.A. Tel: 262-691-2222 FAX: 262-691-0312 E-mail: sales@dynexhydraulics. SPECIFICATIONS PF1000 Series Fixed Displacement Pumps Also refer to "Checkball Pump Installation and Operating Recommendations" Bulletin PSI.CB (dynexpumpinstallation.pdf) CONTACT INFORMATION USA Headquarters

More information

Duplex Filters 40 FLDK 0008(C)-0120(C)

Duplex Filters 40 FLDK 0008(C)-0120(C) Industrial Filters Accumulators Duplex Filters 40 FLDK 0008(C)-0120(C) Filters for inline installation for continuous operating Ball valve change over Optimised flow characteristics by 3D computer aided

More information

Oildyne. 165 Series Hydraulic Power Units. Pressures to 241 bar (3500 psi) Flows to 5.4 lpm (1.4 gpm)

Oildyne. 165 Series Hydraulic Power Units. Pressures to 241 bar (3500 psi) Flows to 5.4 lpm (1.4 gpm) Oildyne Hydraulic Power Units Pressures to 241 bar (3500 psi) Flows to 5.4 lpm (1.4 gpm) 11 Power Unit Features We are pleased to introduce our new power units. The power units let you put more power where

More information

PUMP AND MOTOR DIVISION

PUMP AND MOTOR DIVISION INSTALLATION MANUAL SERIES P2 and P3 MOBILE PISTON PUMP 1 Check model code / compare with your paper work Nameplate of the pump Ordering / Sales Acknowledgement 2 Check rotation of the pump Clockwise rotation

More information

Hydraulic Control Solutions

Hydraulic Control Solutions Hydraulic Control Solutions Vexve s Hydrox hydraulic control solutions are suitable for even the most challenging installation sites and conditions. Specifically designed for district heating and district

More information

Ultipleat High Flow Filter System

Ultipleat High Flow Filter System Data Sheet PIUFFSENa Ultipleat igh Flow Filter System Description The Ultipleat igh Flow filter is a large diameter, coreless, single open ended, pleated cartridge with an inside-to-outside flow pattern.

More information

Chapter 5: Flow Valves

Chapter 5: Flow Valves Catalogue HY11-300/UK Contents Chapter : Flow Valves Series Description Size Mounting Page Parker Standard DIN / ISO 1/4 3/8 1/2 3/4 1 06 10 16 Throttle valves, manual adjustment MVI -2 NS -4 FS With free

More information

QPM3 Low pressure pump for circulation of oil in hydraulic and lubricating systems

QPM3 Low pressure pump for circulation of oil in hydraulic and lubricating systems The Professional Choice in Fluid Management QPM3 Low pressure pump for circulation of oil in hydraulic and lubricating systems The Olaer Group is a global player specialising in innovative, efficient system

More information

E4E PILOT OPERATED DIRECTIONAL CONTROL VALVE WITH ELECTRIC PROPORTIONAL CONTROL SERIES 51

E4E PILOT OPERATED DIRECTIONAL CONTROL VALVE WITH ELECTRIC PROPORTIONAL CONTROL SERIES 51 83 300/100 ED E4E PILOT OPERATED DIRECTIONAL CONTROL VALVE WITH ELECTRIC PROPORTIONAL CONTROL SUBPLATE MOUNTING CETOP P05 p max 250 bar Q max (see specification table) MOUNTING INTERFACE OPERATING PRINCIPLE

More information

ATL Fuel Level Sender Probes

ATL Fuel Level Sender Probes T E C H N I C A L S P E C I F I C A T I O N The ATL EL-AD-151 (Resistance Output) and EL-AD-152 (Voltage Output) Fuel Level Senders are highly advanced sensors for continuously measuring the contents of

More information

CSD WATER REMOVAL FILTERS FOR DIESEL

CSD WATER REMOVAL FILTERS FOR DIESEL CSD CSD WATER REMOVAL FILTERS FOR DIESEL Remove water to extend fuel injector life & increase combustion fuel efficiency Remove free water to saturation point with high single pass efficienc (achieve

More information

Eurovacuum EV Series. Single Stage Oil Sealed Rotary Vane Pump

Eurovacuum EV Series. Single Stage Oil Sealed Rotary Vane Pump Eurovacuum EV Series Single Stage Oil Sealed Rotary Vane Pump Eurovacuum EV Series Single Stage Oil Sealed Rotary Vane Pumps Eurovacuum Company is offering its various products to meet industrial vacuum

More information

Variable Displacement Pump AA10VSO

Variable Displacement Pump AA10VSO Variable Displacement Pump AA10VSO Series 31, Industrial Model, for Open Circuits Axial piston, swashplate design Brueninghaus Hydromatik Sizes 28...140 Nominal pressure 4000 psi Peak pressure 5100 psi

More information

DIESEL FUEL CONDITIONING

DIESEL FUEL CONDITIONING COD FILTRATION DIESEL FUEL CONDITIONING REMOVE WATER & PARTICLES TO EXTEND FUEL INJECTOR LIFE & INCREASE COMBUSTION ENGINE FUEL EFFICIENCY Remove free water to saturation point with high single pass efficiency

More information

SERIES FRI. Maximum working pressure 20 bar Flow rate to 1200 l/min. s.p.a

SERIES FRI. Maximum working pressure 20 bar Flow rate to 1200 l/min. s.p.a SRIS FRI Maximum working pressure bar Flow rate to 1 l/min s.p.a R FRI series filter has been disigned and developed to satisfy the demands pf applications, on return or low preessure line in Hydraulic

More information

Filter Elements E 7.200.9/05.06

Filter Elements E 7.200.9/05.06 HYDAC Filter Elements safeguard the performance and service life of essential and expensive hydraulic components due to their high standard of quality Filter Elements Technical details: Absolute filtration

More information

Single sub-base valve

Single sub-base valve solenoid valves Mini-valves 10 mm Electrical connection... Mounting... Port sizes... Rated temperature... Fluid... Working pressure... Nominal flow... Pneumatic connections Voltage... Power... NC poppet

More information

How To Use A Flowmeter

How To Use A Flowmeter INLINE flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both PNP and NPN) Connection

More information

Volkswagen New Beetle 2.0 Liter 4-cyl General, Engine (Engine Code AEG) 17 Engine-Lubrication system (Page GR-17)

Volkswagen New Beetle 2.0 Liter 4-cyl General, Engine (Engine Code AEG) 17 Engine-Lubrication system (Page GR-17) 17 Engine-Lubrication system (Page GR-17) Lubrication system components, removing and installing Oil pan, removing and installing Oil pressure and oil pressure switch, checking Dynamic oil pressure warning

More information

4/2-Way Pneumatic Solenoid Valve

4/2-Way Pneumatic Solenoid Valve 4/2-Way Pneumatic Solenoid Valve Robust servo assisted piston valve Service friendly manual override Single or block assembly Explosion-proof versions Type 5413 cam be combined with Type 2508 Cable plug

More information

MONO BLOCK DIRECTIONAL CONTROL VALVE TS

MONO BLOCK DIRECTIONAL CONTROL VALVE TS SHIPPING: 2332 S 25TH STREET (ZIP 6815) MAILING: P.O. BOX #669 OMAHA, NE 6816 PHONE: (42) 344-4434 FAX: (42) 341-5419 HTTP://WWW.BRAND-HYD.COM MONO BLOCK DIRECTIONAL CONTROL VALVE TS TS312TSDTSTKJB TS2

More information

Safety for Hydraulics Leak free double check valve, pilot operated, series DERV Cartridge type, two stage

Safety for Hydraulics Leak free double check valve, pilot operated, series DERV Cartridge type, two stage Safety for Hydraulics Leak free double check valve, pilot operated, series Cartridge type, two stage 8 1 1 General description spring closed, pilot operated, cartridge type poppet valve it holds the load

More information

TTC-IIS Series Up to 11 LPM Free Flow

TTC-IIS Series Up to 11 LPM Free Flow 66 Up to 11 LPM Free Flow Typical Applications Gas Analysis Anesthesia Monitors CO 2 Monitors Patient Monitoring Wound Therapy Urinalysis Trace Detection Medical/Training Mannequins Degassing Product Specifications

More information

Ball valve C 16 valve ball completely moulded in place, extremely low clearance volume, high k v value

Ball valve C 16 valve ball completely moulded in place, extremely low clearance volume, high k v value Ball valve C valve ball completely moulded in place, extremely low clearance volume, high k v value Advantage maximum safety due to valve ball completely moulded in place - ball and ball seat cannot be

More information

Denotes New Winner s Circle Product Line. Catalog HY15-3502/US SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO. LPM/GPM BAR/PSI HIGH FLOW VALVE FAMILY

Denotes New Winner s Circle Product Line. Catalog HY15-3502/US SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO. LPM/GPM BAR/PSI HIGH FLOW VALVE FAMILY Catalog HY-5/US Contents SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO. /GPM BAR/PSI HIGH FLOW VALVE FAMILY See individual catalog pages for exact specifications. WAY SPOOL TYPE GS *... X / C9-.. Position,

More information

SHOWERS 85-100 SHOWERS

SHOWERS 85-100 SHOWERS SHOWERS 85-100 85 SHOWERS SHOWER HEADS 87 NEPTUNE 89 SHOWER PANEL SERIES PERFECT TIME SHOWER PANEL SERIES 91 NEPTUNE 1042T 93 PERFECT TIME 1042T 94 NEPTUNE MEDICAL 95 TOUCH SH 1000T 96 NEPTUNE 1032 97

More information

IMPORTANT DOCUMENTATION DO NOT DISCARD!

IMPORTANT DOCUMENTATION DO NOT DISCARD! PART NO.: 6441-263C SERIES GRT 3 JAW PARALLEL GRIPPERS INFORMATION SHEET IMPORTANT DOCUMENTATION DO NOT DISCARD! Use this information sheet to assist with gripper installation and setup. File with maintenance

More information

FILTRATION AMIAD PLASTIC FILTERS, SCREENS & DISCS

FILTRATION AMIAD PLASTIC FILTERS, SCREENS & DISCS 4 AMIAD PLASTIC FILTERS, SCREENS & DISCS Max pressure 10.0 Bar, max temperature 60 O 3/4 to 1 1/2 bodies manufactured from polyacetal 2 bodies and above manufactured from polymade and glass fibre 3/4 to

More information

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply) transmitter (2 wire) / switch for continuous or On/Off Control Indication, monitoring, transmitting and continuous or On/Off control in one device Output signal 4...20 ma, 2-wire for continuous control

More information

PVH131/141 Variable Displacement Piston Pump - 11 Design

PVH131/141 Variable Displacement Piston Pump - 11 Design Service Data Vickers Piston Pumps PVH131/141 Variable Displacement Piston Pump - 11 Design Revised 05/01/97 M-2209-S Maximum Adjustable Stop S Option 913341 Locknut Torque 25-50 N.m. (18-37 lb. ft.) Torque

More information

KDG3V-5/7/8, 10 Series

KDG3V-5/7/8, 10 Series Vickers roportional Valves KDG3V-5/7/8, 1 Series Single-Stage with Hydraulic ilot Operation High Flow roportional Directional Control Valves asic Characteristics Max. pressure.......... up to 35 bar (5

More information

PRESSURE REDUCING CONTROL VALVE

PRESSURE REDUCING CONTROL VALVE Schematics Throttles to reduce high upstream pressure to constant lower downstream pressure Low Flow By-Pass controls at low flows 4 PRESSURE REDUCING CONTROL VALVE with LOW FLOW BY-PASS FEATURE Main Line

More information

RUBBER SLEEVE KNIFE GATE VALVE

RUBBER SLEEVE KNIFE GATE VALVE RUBBER SLEEVE KNIFE GATE VALVE The model knife gate is a wafer valve designed for a wide range of industrial applications. The double-seated design provides bi-directional shut off. The design of the valve

More information

Rexroth Hydraulic Pump A10VO Series User Manual

Rexroth Hydraulic Pump A10VO Series User Manual Rexroth Hydraulic Pump A10VO Series User Manual Rexroth Hydraulic pump A10VO Series User Manual Revised 5/1/2009 Page 1 of 12 Functional Purpose This pump is preferred over a fixed displacement (gear)

More information

Series PVP Variable Volume Piston Pumps

Series PVP Variable Volume Piston Pumps Series PVP Variable Volume Piston Pumps Catalog HY28-2662-CD/US Revised June, 212 hpm12-1.p65, lw, jk 1 Notes Series PVP hpm12-1.p65, lw, jk 2 Introduction Series PVP Series Sizes 6-14 Phased Out For Reference

More information

Pressure Relief. Pressure Control Valve R(C)G(O)-03, 06 and 10; R(C)T(O)-03, 06 and 10 VICKERS. Basic Characteristics. Sectional Illustrations

Pressure Relief. Pressure Control Valve R(C)G(O)-03, 06 and 10; R(C)T(O)-03, 06 and 10 VICKERS. Basic Characteristics. Sectional Illustrations VICKERS Pressure Relief Pressure Control Valve R(C)G(O)-03, 06 and 10; R(C)T(O)-03, 06 and 10 Sectional Illustrations RCG-** Model Shown RCT-** Model Shown Basic Characteristics Type...................

More information

Mustang Series PRESSURE REDUCING CONTROL VALVE WITH PRESSURE SUSTAINING FEATURE. M115-2 (Globe) M1115-2 (Angle) Schematic. Standard Components

Mustang Series PRESSURE REDUCING CONTROL VALVE WITH PRESSURE SUSTAINING FEATURE. M115-2 (Globe) M1115-2 (Angle) Schematic. Standard Components Schematic Throttles to reduce high upstream pressure to constant lower downstream pressure Throttles to maintain minimum upstream pressure PRESSURE REDUCING CONTROL VALVE WITH PRESSURE SUSTAINING FEATURE

More information

AIR OPERATED OIL PUMPS AND KITS

AIR OPERATED OIL PUMPS AND KITS PM 2 AIR OPERATED OIL PUMPS AND KITS PM 2 Oil pump, pressure ratio : 0 Double acting air operated pumps for transferring lubricants and other non-corrosive fluids. Pump includes bung adapter. New Model

More information

How To Make A Fuel Manager Filter/Separator

How To Make A Fuel Manager Filter/Separator The Versatile Diesel Fuel Filtration/Water Separator System From America s Foremost Diesel Technology Innovator STANADYNE The Versatile Fuel Filtration System FOR EVERY DIESEL ENGINE, EVERY DIESEL APPLICATION

More information

Combi switchbox with integrated 3/2 way pilot valve

Combi switchbox with integrated 3/2 way pilot valve H Combi switchbox with integrated 3/2 way pilot valve Construction The GEMÜ combi switchbox with integrated 3/2 way pilot valve for pneumatically operated quarter turn actuators has a micro-processor controlled

More information

6 Crankcase Ventilation

6 Crankcase Ventilation 6 Crankcase Ventilation Introduction... 6-3 Crankcase Ventilation Manager (CVM)... 6-5 Introduction... 6-6 CVM280B..................................... 6-7 CVM280T... 6-10 CVM424B....................................

More information

Pipe threads for tubes and fittings where pressure-tight joints are not made on the threads. (requires PTFE sealing tape or liquid sealant).

Pipe threads for tubes and fittings where pressure-tight joints are not made on the threads. (requires PTFE sealing tape or liquid sealant). Fittings for CO 2 Pipe Threads Pipe thread references quoted in this catalogue conform with the requirements specified in the latest issue and amendments of the following ISO Standards: ISO 7-1 (BS21)

More information

08.08 Vic-Check Valves

08.08 Vic-Check Valves The check valves are a product of computer-assisted innovative engineering with quality features including a new hydrodynamically efficient profile. The Vic-Check valve utilizes a spring-assisted, single-disc

More information

Water Separator. Main Line Filter. Mist Separator. Micro Mist Separator 150C 250C 350C 450C AMG 550C 2C 4C 8C 11C AFF 22C 37B 75B 150C 250C 350C 450C

Water Separator. Main Line Filter. Mist Separator. Micro Mist Separator 150C 250C 350C 450C AMG 550C 2C 4C 8C 11C AFF 22C 37B 75B 150C 250C 350C 450C Water droplet removal Water Separator Water droplet separation rate: % Model Flow capacity l/min (ANR) Max. flow capacity at 0.7 MPa inlet pressure 300 750 1,500 AMG 2,0 AMG to AMG/ Large dust particle

More information