2011 DC Electropumps Bull. Rotation Ø 15 6,45 3,5 5,7
|
|
- Kristin Flynn
- 8 years ago
- Views:
Transcription
1 Ø 5 ±. DC Electropumps Bull,5 Rotation,5 5,7
2 Fax B... Electro pumps Bull series MODEL CODE EPB,5 DC /S5 K, V** Electro Pump Bull series Gear pump displacement (cc/rev (see tables E..: Dc electric motor power (kw and type (see tables E..:,5 DC (/T/S:,5kW VDC (/thermal switch/start switch,5 DC (/T/S:,5kW VDC (/thermal switch/start switch,5 DC (/T/S:,5kW VDC (/thermal switch/start switch,5 DC (/T/S:,5kW VDC (/thermal switch/start switch, DC (/T/S:,kW VDC (/thermal switch/start switch, DC (/T/S:,kW VDC (/thermal switch/start switch Optional Starting Switch: (see tables E..: /S5: 5 A starting switch (for Ø motors Optional Relief Valve (see tables E..: V bar V bar V5 5 bar V5 7 5 bar K,, K,, K,, K,, K,,7 K,, K,, K,, K,7,7 K,, B...
3 Fax B... Electro pumps Bull series Option: foot mounting MODEL CODE EPB, DC /S5 K, V** Electro Pump Bull series E5 Option: foot mounting Gear pump displacement (cc/rev (see tables E..: Dc electric motor power (kw and type (see tables E..:, DC (/T/S:,kW VDC (/thermal switch/start switch, DC (/T/S:,kW VDC (/thermal switch/start switch, DC (/T/S:,kW VDC (/thermal switch/start switch Optional Starting Switch: (see tables E..: /S5: 5 A starting switch (for Ø motors Optional Relief Valve (see tables E..: V bar V bar V5 5 bar V5 7 5 bar K,,7 K,, K,, K,, K,7,7 K,, K,7, K,, K5,, K,, K7,, B...
4 Fax B... Electro pumps Bull 5 series Option: foot mounting MODEL CODE EPB5, DC /S K,7 V** Electro Pump Bull 5 series E5 Option: foot mounting Gear pump displacement (cc/rev (see tables E..: Dc electric motor power (kw and type (see tables E..:, DC (/T/S:,kW VDC (/thermal switch/start switch, DC (/T/S:,kW VDC (/thermal switch/start switch Optional Starting Switch: (see tables E..: /S: A starting switch (for Ø 5 motors Optional Relief Valve (see tables E..: V bar V bar V5 5 bar V5 7 5 bar K,,7 K,, K,, K,, K,7,7 K,, K,7, K,, K5,, K,, K7,, B...
5 Fax B... Electro pumps Bull 5 series MODEL CODE EPB5,HD DC /S K, V** Electro Pump Bull 5 series E5 Option: foot mounting Gear pump displacement (cc/rev (see tables E..: Dc electric motor power (kw and type (see tables E..:,5HD DC (/T/S:,5kW VDC (/thermal switch/start switch,hd DC (/T/S:,kW VDC (/thermal switch/start switch,hd DC (/T/S:,kW VDC (/thermal switch/start switch Optional Starting Switch: (see tables E..: /S: A starting switch (for Ø 5 motors Optional Relief Valve (see tables E..: V bar V bar V5 5 bar V5 7 5 bar K,,7 K,, K,, K,, K,7,7 K,, K,7, K,, K5,, K,, K7,, B...
6 Fax B... EPB DC motors Starting switch option 5 5,5,5 Protection degree: IP5 Insulation class: F M,5 Ø Thermal protection option Ø,5 Ø Ø7,5,5 Rotation Weight:, kg Permanent magnets Code Nominal duty cycle 5W V DC motor,5 DC MCS5 5W V DC motor,5 DC MCS5 W V DC motor, DC MCS W V DC motor, DC MCS 5W V DC motor with thermal protection,5 DC/T MCST 5W V DC motor with thermal protection,5 DC/T MCST 5W V DC motor with thermal protection,5 DC/T MCST5 5W V DC motor with thermal protection,5 DC/T MCST5 W V DC motor with thermal protection, DC/T MCST W V DC motor with thermal protection, DC/T MCST S: min : % ED S: min : % ED S: min : % ED S: min : % ED S: min : 5% ED S: min : 5% ED S: min : % ED S: min : % ED S: min : % ED S: min : % ED Nominal Nominal speed current rpm A rpm 5 A rpm A rpm A rpm A rpm 5 A rpm A rpm 5 A rpm A rpm A Options or V DC 5 Amp start switch mounting kit Remote wired control with two buttons and m cable (see U.. S5 DC S5 DC P M7SC M7SK (V DC M7SC M7SK(V DC P (single acting P P (double acting Notes: the starting switch mounting kit is provided when specifying the /S5 in EPB. When ordering spare starting switches, it must be ordered separately (code: M7SK. Coupling Coupling for Ø DC motors and gr. pump Note: the coupling is already included when specifying the motor in EPB. E7 Flange Flange for Ø DC motors and gr. pump E Note: the flange is already included when specifying the motor in EPB assembly code. B...
7 Fax B... EPB DC motors Starting switch option M Ø Ø Ø, Thermal protection option Ø 5 ±. Rotation,5 Compound wound Protection degree: IP5 Insulation class: F Weight: 7,5 kg 7,5 5,7 Code W V DC motor, DC MCS W V DC motor, DC MCS W V DC motor with thermal protection, DC/T MCST W V DC motor with thermal protection, DC/T MCST W V DC motor with thermal protection, DC/T MCST Nominal duty cycle S: min : 7,5% ED S:,min :,5% ED S: min : 7,5% ED S:,min : 7,5% ED S:,min :,5% ED Nominal Nominal speed current rpm A rpm A rpm A rpm A rpm A Options Starting switch 5A or V DC mounting kit DC motors plastic cover S5 DC S5 DC M7SC M7SK (V DC M7SC M7SK(V DC F F Notes: the starting switch mounting kit is provided when specifying the /S5 in EPB. When ordering spare starting switches, it must be ordered separately (code: M7SK. Coupling Coupling for Ø Ø5 DC motors and gr. pump Note: the coupling is already included when E specifying the motor in EPB. Flange Flange for Ø Ø5 DC motors and gr. pump DC motors plastic cover Note: the flange is already included when specifying E the motor in EPB assembly code. Weight:,7 kg 7 Ø B...
8 Fax B... EPB5 DC motors XM Ø 5 Ø Ø Ø 5 Ø,5 7,5 Compound wound Protection degree: IP Insulation class: F Weight: kg 5,7 Rotation Code W V DC motor with thermal protection & fan, DC/T W V DC motor with thermal protection & fan DC/T Nominal Nominal Nominal duty cycle speed current S: min MCST : 7,5% ED rpm A S: min 5 rpm 7 A MCST : 7,5% ED Spare part code Options Starting switch A or V DC S DC S DC M7ZC (V DC M7ZC (V DC Coupling Coupling for Ø and Ø5 DC motors E Note: the coupling is already included when specifying the motor in EPB. Flange Flange for Ø and Ø5 DC motors E Note: the flange is already included when specifying the motor in EPB. B...
9 Fax B... EPB5 DC motors with fan cooling 5 N 7 M 5 Series wound Protection degree: IP Insulation class: F 5 Ø Ø5 Ø5 Ø j 5 5 Rotation Weight:,5 kg Front attachment: B Code code Spare part code Nominal Nominal Nominal Mounting duty cycle speed current kit 5W V DC motor thermal protection & fan,5hd DC/T MBCST5 S: min 7 rpm A XB W V DC motor thermal protection & fan HD DC/T MBCST S: min 7 rpm 7 A XB W V DC motor thermal protection & fan HD DC/T MBCST S: min rpm A XB Options Starting switch A or V DC S DC S DC M7ZC ( V DC M7ZC ( V DC Coupling Two pieces coupling for Ø 5 DC motors E E Note: the coupling is already included when specifying the motor in EPB. Flange Flange for Ø 5 DC motors E5 Note: the flange is already included when specifying the motor in EPB. Other B DC motors for heavy duty or special applications They are available with Ø5, Ø5 or Ø in multiple executions, engineered to perform heavy duty cycles and tailor made to suit each specific application, with or without fan cooling or thermal protection. They are mounted on the central manifold with B standard mounting kits (see tables U.. and following. To properly choose these motors, following minimum information must be provided to our technical office: motor power and voltage, application type, duty factors: S [min] continuous running time and [%] percentage of running time on total cycle time, required motor speed, 5 quantity to be supplied. B...
10 Fax B..5. DC motors choice and electric connection schemes DC motors choice Once required pressure and flow and available voltage ( or V DC are known, you can select the motor checking on each provided diagram if a pump displacement is available at the intersection of pressure and flow values. On the relevant I curve you obtain the absorbed current. When the intersection point is not exactly on a pump curve, choose the closer pump. On the right hand diagram, from the current value, you can easily obtain the maximum allowed S (min and (% values. S gives the allowable motor continuous running time in minutes, gives the allowable running time in % of the total cycle. If obtained S and values are not enough for required duty cycle, choose a bigger motor and repeat the calculation on the new motor curves.,7,,,,,,,,,,,,, P (bar Electric connection schemes I (A 5 S, 7,7 W V Q (l/min Example: For our application we have following data: flow = l/min, max pressure = bar, not clearly defined duty cycle. We check on, Kw V DC motor diagram and see there is a pump available. We choose from curves, pump: a, cm/rev pump. On the corresponding I curve we read 5 A absorbed current. In these conditions on the S / diagram we read that the DC motor can work for maximum 7 min (S, that is 7% ( of the total cycle, i.e. after 7 min working, the motor should cool down for at least min. The total cycle time is calculated adding the working time and the idle time (7% working time plus % idle time, in this case min. If this duty cycle is not adequate for our application, we must choose a higher power DC motor and check the relevant diagram again. S(min (% White Thermal switch MSV Red Starting switch Red Starting switch Black White Remote control P M Single effect cylinder Black Directional valve Brown Grey (up M Thermal switch Yellow/ Green Black (down Starting switch Remote control P Double effect cylinder M B..5.
11 Fax B... DC motors diagrams EBCS5 5 W V I (A,,,,, 5 5,,,,, 7,,.5 I ( 5 I (, I (,, 7,,.5 I (A EBCS5 5 W V I ( S S,,, , Q (l/min Q (l/min.5 S(min (% P (bar, S(min (% 5 P (bar Test made with battery 5Ah 5% charged at 5 C and mineral oil ISO VG at C,,,, I (,, I,,, (,,, 5, I ( I (,, I (, 7 I (,,, I (, I (, I (A EBCS W V I (A I ( EBCS W V, S,, 5, 5 Q (l/min Q (l/min, S(min 5 (% P (bar,,, 5 5 S, 5 S(min (% P (bar Test made with battery 5Ah 5% charged at 5 C and mineral oil ISO VG at C,, I (,7, 5, I (,,,,7,,,,, I (A,,7, 7, EBCS W V I (A EBCS W V,,, I ( I (, S,,, 5 S,, Q (l/min,, Q (l/min 5,, 5 5 P (bar 5 S(min (%,, P (bar S(min,5 (% 5 7,5,5 5 Test made with battery 5Ah 5% charged at 5 C and mineral oil ISO VG at C B...
12 Fax B..7. DC motors diagrams EBCST W V I (A,,,, I (,, I (A,,,,,,7,,,, 7,,, EBCST W V 5,, 5,, S 5 Q (l/min Q (l/min, 5,,, S,,, 5 S(min (% P (bar P (bar 5 S(min (% 5 Test made with battery 5Ah 5% charged at 5 C and mineral oil ISO VG at C I (A, S 5 Q (l/min Q (l/min S,,,,7 5 5,, 5 I (,,, 5, I (,,,,, 5 7, I (, I (,,7,,, I (, 7,,,, I ( I (,,,, I (A EBCST5 5 W V HD EBCST W V 5 5 S(min P (bar (% 5,, P (bar S(min (% 5 5 5,,, I (7,, 7,, I (7,,,, I (A 7,, EBCST W V HD 7,, I (A, EBCST W V HD Test made with battery 5Ah 5% charged at 5 C and mineral oil ISO VG at C, 7,, 5 S 5 Q (l/min,, 5 P (bar 5,7 S(min 5 (% 5 5, 5 5, S Q (l/min,, P (bar S(min (% Test made with battery 5Ah 5% charged at 5 C and mineral oil ISO VG at C B..7.
13 Fax B... Gr. gear pumps 5 n. Ø 5,5 5,5, Ø 55 Ø N / BSPP,5 5 Alluminium adapter flange for group Code: E55 n. Ø,5 n. M5 Weight:, Kg field E5 ** ** K Size: see spare part code on below table Pump type: K = K type with front/rear ports KL = KL type with lateral ports Nominal displacement: (cc/rev see below table, Ports: = front/rear ports = lateral ports Available range Nominal Peak Intermittent Continuous Max speed N Displacement pressure pressure pressure (rpm (mm (cc/rev (bar (bar (bar Bolts* (mm Spare part code Weight, 5,5 M5x55 E5, Kg 7,5 M5x55 E5,5 Kg 5,5 M5x E5, Kg,,, 5 5,5 M5x5 E, Kg, 55,5 M5x5 E, Kg,5 57, M5x7 E5,5 Kg Other pumps executions with different pressure/speed ratings are available on request. * A proper washer is to be forecast to adapt bolt lenght Main features Oil temperature Inlet pressure Fixing bolts 5 C,7 < P <, bar (absolute pressure x M. class steel tightening torque: 5 Nm Peak pressure: cycle s ON Pressure definition Intermittent pressure: cycle s ON Continuous pressure: cycle always ON Filtration setting 5 5 µ B...
14 Fax B... Gr. gear pumps 5 N,5 Ø 7 Ø n. Ø, Option: relief valve / BSPP (KL type field E ** ** K Size: see spare part code on below table Pump type: K = K type KL = KL type with lateral ports Nominal displacement: (cc/rev see below table, Ports: = front/rear ports = lateral ports Optional relief valve: (bar see table E.. V** Available range Nominal Peak Intermittent Continuous Max speed N Displacement pressure pressure pressure (rpm (mm (cc/rev (bar (bar (bar Bolts* (mm Spare part code Weight, 5 5 Mx Mx75 E** E**,77 Kg,, 5 5 Mx75 E**5, Kg, 5 5 Mx, Kg, 5 5 Mx E** E**5, Mx5 E**,7 Kg,7 7 Mx5 E**7, Kg, 7 Mx E**, Kg 7 7 Mx E**,5 Kg Mx E** Kg,,,77 Kg,5 Kg Other pumps executions with different pressure/speed ratings are available on request. * Proper washers are to be forecast to adapt bolt lenght Main features Oil temperature Inlet pressure Fixing bolts 5 C,7 < P <, bar (absolute pressure x M. class steel tightening torque: 5 Nm Peak pressure: cycle s ON Pressure definition Intermittent pressure: cycle s ON Continuous pressure: cycle always ON Filtration setting 5 5 µ B...
15 Fax B... Accessories VMDC 5,5 max ø 5 ø,7 / UNF A,5 P T Hex. Hex. Hex. Hydraulic symbol P VMDC Direct acting relief valve Nominal size: = l/min B Working range: A = bar B = bar C = 5 bar D = 7 5 bar Main features Adjusting device: = screw (std = handwheel Series T Max pressure 5 bar Max flow l/min Weight,5 kg Recommended tightening torque: Nm Recommended filtration settings: 5 5 µ Oil temperature: C Foot mounting support E5 Weight:, Kg 5 Ø,5 n. ø n. s E5 B...
2011 AC & DC Hydraulic Power Packs Micro
AC & DC Hydraulic Power Packs Micro POWER PACKS MICRO series ordering code PPM/- QUICK SELECTION GUIDE AC & DC electric motors DC motors,5 DC_T VDC motor - 5W - Ø 8 + thermal switch,5 4DC_T 4VDC motor
More information2011 AC & DC Hydraulic Power Packs Compact
11 C & DC Hydraulic ower acks Compact OWER CKS COMCT series ordering code C11/-1 QUICK SELECTION GUIDE C & DC electric motors DC motors Section,15 1DC_T 1VDC motor - 15W - Ø 8 + thermal switch,15 4DC_T
More informationSeries TMM Axial Piston Motor. Technical Information
Series TMM Axial Piston Motor Technical Information General Description GENERAL DESCRIPTION These motors are designed primarily to be combined with other products in closed circuit systems to transfer
More informationSOLENOID VALVES 3-4 WAY
SOLENOID VLVES - WY IE/C// CT: FP/VCR Page: 7 SHEET: / SOLENOID VLVES - - WY CV SOLENOID VLVES -WY/-POSITION /- UNF.7 5.7 The electric valve is a -way -position directional electrically controlled Slight
More informationCustom configuration such as modified angle dimensions, other flange standards, 3-way function, alternative materials.are available on request.
LEAKVALVE: HIGHLIGHTS The core of this valve is a diaphragm in stainless steel 316L, gold plated. Robust, it cannot be damaged with any normal methods. The dead volume is kept as small as possible. There
More informationProportional relief valves type AGMZO-TERS, AERS two stage, with integral or remote pressure transducer, ISO 6264 size 10, 20 and 32
www.atos.com Table F040-1/E Proportional relief valves type AGMZO-TERS, AERS two stage, with integral or remote pressure transducer, ISO 6264 size 10, 20 and 32 AGMZO are two stage poppet type proportional
More information3/2- and 2/2-way cartridge valve type BVE
3/2- and 2/2-way cartridge valve type BVE for any flow direction, zero leakage, all ports pressure resistant Flow Q max = 70 lpm Perm. pressure p max = 400 bar Additional valves with same function: ' Type
More informationPRODUCT CARD GEAR PUMPS AND MOTORS ORS GROUP 1 E0.14.0503.02.01 TM GEAR PUMPS AND MOTORS GROUP 1 INDEX Page 1 - GENERAL INDEX Page 2 - Features - Quick guide Page 3 - Features - General - Working conditions
More informationVolkswagen New Beetle 2.0 Liter 4-cyl General, Engine (Engine Code AEG) 17 Engine-Lubrication system (Page GR-17)
17 Engine-Lubrication system (Page GR-17) Lubrication system components, removing and installing Oil pan, removing and installing Oil pressure and oil pressure switch, checking Dynamic oil pressure warning
More informationLine-Mounted Valves L Series
Spare Part Kit for Valve Series B1LSAD3 Line-Mounted L Series Accessories Spare Part Kits All Series Valve Series B1LSAD3 40.1609 Incl. O-rings, gaskets, spring or muffl er Spare Part Kit for Valve Series
More informationPPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES
PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES BUSHING WITH PLUG CONNECTION WITH OUTER CONE PPS CHARACTERISTICS The PPS bushing can be used as a fixed section for the entry of medium
More informationHydraulic Control Solutions
Hydraulic Control Solutions Vexve s Hydrox hydraulic control solutions are suitable for even the most challenging installation sites and conditions. Specifically designed for district heating and district
More informationPressure relief valves Size 6
Pressure relief valves Size 6 direct controlled Interface to DIN 24 340 and ISO 6264 PN [p max. ] = bar 750400.06.0.06 Description (standard units) Design The pressure relief valves of Type D B C 6 are
More informationMANTA Piston Distributor for Oil and Fluid Grease
MANTA Piston Distributor for Oil and Fluid Grease Function Piston distributors meter out and distribute the oil delivered by an intermittently actuated pump. The quantities of oil for the individual lube
More informationVariable Displacement Pump AA10VSO
Variable Displacement Pump AA10VSO Series 31, Industrial Model, for Open Circuits Axial piston, swashplate design Brueninghaus Hydromatik Sizes 28...140 Nominal pressure 4000 psi Peak pressure 5100 psi
More informationA10VSO Nominal size 18 see RD 92712 A10VSO Nominal size 28...140 see RD 92711
A10VO Nominal size 18 see RD 92712 A10VO Nominal size 28...140 see RD 92711 The variable displacement axial piston pump A10VO in swashplate design was designed for hydrostatic drives in open circuits.
More informationVolkswagen Jetta, Golf, GTI 1999, 2000 2.8 Liter VR6 2V Engine Mechanical, Engine Code(s): AFP 17 Engine-Lubrication (Page GR-17)
17 Engine-Lubrication (Page GR-17) Lubrication system components, removing and installing Oil filter housing, disassembling and assembling Oil pan, removing and installing Oil pressure and oil pressure
More information2-Way heavy duty flow control, with pressure compensated, solenoid and load sensing controlled priority flow
2-Way heavy duty flow control, with pressure compensated, solenoid and load sensing controlled priority flow RE 18309-64/04.10 1/6 Replaces: RE 00171/02.07 A-VRFC2C-VEI-VS-LS 0M.28.03.80 - Y - Z Description
More informationSingle sub-base valve
solenoid valves Mini-valves 10 mm Electrical connection... Mounting... Port sizes... Rated temperature... Fluid... Working pressure... Nominal flow... Pneumatic connections Voltage... Power... NC poppet
More informationCartridge Valves. Solenoid Valves. Vickers. Screw-in Cartridge Valves. Maximum Pressure 210 bar (3000 psi) Maximum Flow 227 l/min (60 USgpm)
Vickers Cartridge Valves Solenoid Valves Screw-in Cartridge Valves Maximum Pressure bar ( psi) Maximum Flow 7 l/min (6 USgpm) Rev /99 77 Introduction For over seventy years, Vickers has provided its customers
More informationGROENEVELD AUTOMATIC GREASING SYSTEMS
GROENEVELD AUTOMATIC GREASING SYSTEMS TWIN Parts & Accessories Book Pumps, Fittings, Injectors, Lining, etc. www.groeneveld-group.com 1 TWIN ELECTRICAL Item Part # Description 1 F113966 Switch 24V 2 F122991
More informationFixed displacement vane pumps
Fixed displacement vane pumps RE 1335/1.5 Replaces: 11.2 1/22 Types PVV and PVQ Nominal sizes 18 to 193 Series 1X Maximum operating pressure 21 bar Maximum displacement 18 to 193 cm 3 Doppelpumpe_d_ Double
More informationHERZ-Thermal Actuators
HERZ-Thermal Actuators Data Sheet 7708-7990, Issue 1011 Dimensions in mm 1 7710 00 1 7710 01 1 7711 18 1 7710 80 1 7710 81 1 7711 80 1 7711 81 1 7990 00 1 7980 00 1 7708 11 1 7708 10 1 7708 23 1 7709 01
More informationElectric Rotary Actuator - On/Off or programmable control actuator
Electric Rotary Actuator - On/Off or programmable control actuator Direct mounting on quarter-turn valves Manual override standard Corrosion resistant Adjustable limit switches Multi-voltage version Type
More informationRotary actuators Rotary wing drives Series RAK. Brochure
Brochure 2 Rotary wing drives, angle of rotation: 30-270 Rotary wing drive, double-acting axis geometry: single 4 Rotary wing drives, angle of rotation: 90-270 Rotary wing drive, double-acting axis geometry:
More informationSteering unit. Table of contents. Features RE 11872/05.06. Type LAGL. Frame sizes 500 to 1000 Component series 1X Maximum flow 80 l/min
Steering unit RE 11872/05.06 /10 Type LAGL Frame sizes 500 to 1000 Component series 1X Maximum flow 80 l/min H7375 Table of contents Contents Page Features 1 Ordering code 2 Function, section 3 Device
More informationFluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS
Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS up to size 381; to PN 0.5; to T = 80 C 1. Description 1.1. General FSA fluid level gauges, FSK fluid level sensors and TS temperature
More informationPOSEIDON 2-29, 2-25 & 2-22 POSEIDON 2-29, 2-25 & 2-22 XT
POSEION 2-29, 2-25 & 2-22 POSEION 2-29, 2-25 & 2-22 XT Repair Manual Index A. Safety precautions 3 B. Technical data 4 C. Structure 5-6. Service / Repair 7-23 E. Tools 24 F. Function 25-26 G. Electric
More informationCooling system components, removing and installing
Page 1 of 34 19-1 Cooling system components, removing and installing WARNING! The cooling system is pressurized when the engine is warm. When opening the expansion tank, wear gloves and other appropriate
More informationSCP 012-130 ISO. Other advantages: SCP 012-130 ISO is a series of piston pumps with a fixed displacement for mobile and stationary hydraulics.
SCP 012-130 ISO is a series of piston pumps with a fixed displacement for mobile and stationary hydraulics. SCP 012-130 ISO covers the entire displacement range 12-130 cmᶟ rev. at a maximum pressure of
More information3-Way heavy duty flow control, with pressure compensated and solenoid controlled priority flow
1/6 RE 18309-3/06.10 Replaces: RE 18309-3/04.10 3-Way heavy duty flow control, with pressure compensated and solenoid controlled priority flow A-VRFC3C-VEI-VS 0M.43.20.80 - Y - Z Description The flow control
More informationFluid. Flu. Fluid Fluid. uid Power d Power P. Fluid Power P. Fluid Power. Fluid Power Power. d Power. Directional Cetop Valves DCV 03.
Catalogue Directional Cetop Valves DCV 03 Power Flu uid Power d Power P wer Power Power Power Power Power d Power Power Power ower Power Power wer Power Power P Power Power Powe d Power Power Power Power
More information2/2 and 3/2 Way Size 6 Seat Valves
2/2 and 3/2 Way Size 6 Seat Valves Directly operated Interface and subplate dimensions according to DIN 24340 and ISO Line connection port size G 3/8" Cartridge design PN [p max. ] = 315 bar 7501856.06.12.08
More informationChapter 5: Flow Valves
Catalogue HY11-300/UK Contents Chapter : Flow Valves Series Description Size Mounting Page Parker Standard DIN / ISO 1/4 3/8 1/2 3/4 1 06 10 16 Throttle valves, manual adjustment MVI -2 NS -4 FS With free
More informationFIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES
BQ FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES Versatility, power, compactness and low running costs are the main characteristics of B&C vane pumps. All the components subject to wear are contained
More informationSensors. Sensors. All Cylinders. Specifications. Features: Features Type REED HALL EFFECT NPN or PNP. Ø8mm - 125mm
Specifications Features Type REED HALL EFFECT NPN or PNP Applicable Series Configurations Construction Materials Body Mounting Bracket Cable Characteristics Operating Temperature Accuracy All Cylinders
More informationTTC-IIS Series Up to 11 LPM Free Flow
66 Up to 11 LPM Free Flow Typical Applications Gas Analysis Anesthesia Monitors CO 2 Monitors Patient Monitoring Wound Therapy Urinalysis Trace Detection Medical/Training Mannequins Degassing Product Specifications
More informationSeries PVP Variable Volume Piston Pumps
Series PVP Variable Volume Piston Pumps Catalog HY28-2662-CD/US Revised June, 212 hpm12-1.p65, lw, jk 1 Notes Series PVP hpm12-1.p65, lw, jk 2 Introduction Series PVP Series Sizes 6-14 Phased Out For Reference
More informationDUGARD. Machine Tools Since 1939. Dugard 700L Series Heavy Duty CNC Lathes. www.dugard.com
DUGARD Machine Tools Since 1939 Dugard 700L Series Heavy Duty CNC Lathes www.dugard.com Dugard 700L Heavy Duty CNC Lathe 2000, 3000 or 4000mm bed length Designed for easy and convenient operation The concave
More informationE4E PILOT OPERATED DIRECTIONAL CONTROL VALVE WITH ELECTRIC PROPORTIONAL CONTROL SERIES 51
83 300/100 ED E4E PILOT OPERATED DIRECTIONAL CONTROL VALVE WITH ELECTRIC PROPORTIONAL CONTROL SUBPLATE MOUNTING CETOP P05 p max 250 bar Q max (see specification table) MOUNTING INTERFACE OPERATING PRINCIPLE
More informationTool Turrets and Tool Discs
Our other products Automatic Tool Changer Chucking Cylinders Tool Discs Indexing Tables Tool Turrets and Tool Discs Pragati Automation Pvt. Ltd. 1, IV Phase, 11th Cross, Peenya Industrial Area Bangalore
More informationWE-350 Series ¼ Turn Electric Actuator
WE-350 Series ¼ Turn Electric Actuator Operation and Installation Manual Pg 1 (Rev. 020113) Table of Contents 1.0 General 1.1 Pre-Installation Inspection 1.2 Storage 1.3 Features & General Information
More informationVARIABLE DISPLACEMENT AXIAL PISTON PUMPS. For truck applications
VARIABLE DISPLACEMENT AXIAL PISTON PUMPS For truck applications TVP FEATURES Variable displacement axial piston pumps swash plate design ideally suited for open circuit truck applications. The compact
More informationHydraulic Flow Control Valves
Webtec Products Limited Hydraulic Flow Control Valves Quality Hydraulic Components from the Webtec Range CONTENTS DESCRIPTION PAGE No. ILFC Series Fixed Flow Pressure Compensated Control Valve 1 VFC Series
More informationThe SF2 series are designed for reservoir side-wall mounting applications, suitable for flow rates to 850 l/min and filtration from 25 to 250 micron.
D e s c r i p t i o n 500 The SF2 series are designed for reservoir side-wall mounting applications, suitable for flow rates to 850 l/min and filtration from 25 to 250 micron. A major feature of these
More informationContractors Guide Central Inverter System Installation
Contractors Guide Central Inverter System Installation Step By Step Procedures 2,200 Watt/VA 6 Step Installation 1. Mount Bottom Cabinet 2. Mount Top Cabinet 3. Install Batteries 4. Install Conduit 5.
More informationSeries 7500 Torque Sensor
Properties PTO (Power Take-Off) shaft with integrated torque and angle measurement Non-contact measurement system, high robustness Plug & Play solution, no additional electronics required Performance Measurement
More informationPRODUCTS DC MOTORS BLPM MOTORS AC MOTORS CONTROLLERS
D R I V E S Y S T E M S PRODUCTS DC MOTORS BLPM MOTORS AC MOTORS CONTROLLERS The vision of Iskra Avtoelektrika is to be: One of the world's leading manufacturers of electric motors and controllers for
More informationD.C. Motors. Products and specifications subject to change without notice.
D.C. Motors Order/Technical Support - Tel: (8) 677-5 / FAX: (8) 677-865 / www.crouzet-usa.com / DC Motors Selection guide Gearbox Speed Torque max (Nm).5. Type of Gearbox 8 8 8. Power usable (w) Torque
More informationARB AIR LOCKER Air Operated Locking Differentials
CKMTA12 & CKMTA24 On-Board Air Compressor Kit, Maximum Performance Specs: ITEM # QTY DESCRIPTION PART # NOTES 01(a) 2 COMPRESSOR ASSEMBLY (12V) CKM01 1 Voltage 12 Volts (CKMTA12), 24 Volts (CKMTA24) 01(b)
More informationABLOY EL614 Motor lock with bolt Abloy Oy An ASSA ABLOY Group company EL614 42/52 25/35 25 22 263.5 225 38.2 17.3 3 10 2 Contents TECHNICAL DATA... 4 INSTALLATION... 5 WIRING DIAGRAM... 6 DRILLING SCHEME...
More informationSIRIUX. SINGLE AND DOUBLE HIGH EFFICIENCY CIRCULATORS Heating Air-conditioning OPERATING LIMITS APPLICATIONS. 28 m 3 /h* Heads up to: Flows up to:
OPERATING LIMITS Flows up to: m /h* Heads up to: m C Max operating pressure: bars Temperature range: - à + C Max ambient temperature: + C ND of orifices: à * m /h: parallel operation SIRIUX SINGLE AND
More informationFIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES
BQ FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES Versatility, power, compactness and low running costs are the main characteristics of B&C vane pumps. All the components subject to wear are contained
More informationABLOY DA60 SWING DOOR OPERATOR Installation and commissioning manual Abloy Oy An ASSA ABLOY Group company APPROVALS / STANDARDS Low Voltage directive 7//EEC as amended by the directive 9/68/EEC EMC directive
More informationTECHNICAL INFORMATION
TECHNICAL INFORMATION P 1 / 5 Model No. Description 8390D Cordless Percussion Driver Drill 13mm CONCEPT AND MAIN APPLICATIONS Model 8390D has been developed by adding percussion mechanism to Model 6390D.
More informationThe Yachtmans Choice...
Ref: 1740, Nov 2015 The Yachtmans Choice... A competitive price 10 to 150 hp, engineered in the UK Advanced, compact, quiet reliable engines Easy engine replacement, with our special feet option Amazing
More informationEurovacuum EV Series. Single Stage Oil Sealed Rotary Vane Pump
Eurovacuum EV Series Single Stage Oil Sealed Rotary Vane Pump Eurovacuum EV Series Single Stage Oil Sealed Rotary Vane Pumps Eurovacuum Company is offering its various products to meet industrial vacuum
More informationFIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES
BQ FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES Versatility, power, compactness and low running costs are the main characteristics of B&C vane pumps. All the components subject to wear are contained
More informationCat Electronic Technician 2015A v1.0 Product Status Report 4/20/2016 2:49 PM
Page 1 of 19 Cat Electronic Technician 2015A v1.0 Product Status Report 2:49 PM Product Status Report Parameter Value Product ID WRK00337 Equipment ID WRK00337 Comments A01-52 C9 330D (THX37891) Parameter
More informationOutput torques up to 8000 Nm. General features. Protection. External coating. Working temperature range
Type series booklet 8521.15/2--10 ACTELEC 31 to 800 (BERNARD) 1/4 turn electric actuators (irreversible reducer with multi -turn electric actuator ACTELEC 31: screw -nut kinematics ACTELEC 200 to 800:
More informationTitan Makina Ltd. Şti. 1160. Sok. No: 9 Ostim 06370 Ankara Tel: + 90 312 354 9977 Fax: + 90 312 385 5611 Web: www.titanltd.com.
IS26 Concrete Spraying Machine IS26 Concrete Spraying Machine TECHNICAL SPECIFICATIONS Manipulator Max. vertical spraying reach : Max. horizontal spraying reach : Working lights : Spraying Head Rotation
More informationDXPE*J 85 320/215 ED. DIRECtIONAL CONtROL VALVE PILOt OPERAtED, WItH OBE AND FEEDBACK. Q max (see performance table) SERIES 30
85 320/215 ED DXPE*J DIRECtIONAL CONtROL VALVE PILOt OPERAtED, WItH OBE AND FEEDBACK SUBPLAtE MOUNtINg DXPE5J CEtOP P05 DXPE5RJ ISO 4401-05 (CETOP R05) DXPE7J ISO 4401-07 (CETOP 07) DXPE8J ISO 4401-08
More informationExtremely compact in size to allow direct flange-mounting on vehicle engine or gearbox PTOs.
TXV - Presentation pumps with Load Sensing control variable displacement piston pumps ADVANTAGES pumps are variable displacement with pressure-flow control called Load Sensing. They self-regulate to give
More informationOildyne. 165 Series Hydraulic Power Units. Pressures to 241 bar (3500 psi) Flows to 5.4 lpm (1.4 gpm)
Oildyne Hydraulic Power Units Pressures to 241 bar (3500 psi) Flows to 5.4 lpm (1.4 gpm) 11 Power Unit Features We are pleased to introduce our new power units. The power units let you put more power where
More information15/40/80CN Series Medium Pressure Filters
1/4/8CN Series Medium Pressure Filters Max 32 l/min - 7 bar Global Filtration Technology 1/4/8CN Series TYPICAL APPLICATIONS Compressor Lube Oil Off-line Filter Loops Machine Tools (Automotive Standard)
More information8W! consumption. 26,5 db IP45. BATHROOM EXTRACT FANS SILENT-100 DESIGN 3C Series
SILENT-1 Series Range of axial extractors with airflow rates of 85 m 3 /h, for connection to 1 mm diameter circular ducting. Motor mounted on silent-elastic-blocks which absorb the vibrations and allow
More informationVisions become real. Temperature control and cooling systems. The innovative and reliable solution
Temperature control and cooling systems The innovative and reliable solution With our PulseTemp equipment you have the option of up to 72 cooling circuits in the impulse cooling, temperature control, temperature
More informationDiesel Generating Set
MODEL Standby Power(50Hz) Prime Power(50Hz) 44KW /55KVA 40KW /50KVA Standard Features General Features: Engine( DCEC Cummins 4BTA3.9 -G) Radiator 40 O C max,fans are driven by belt, with safety guard 24V
More information2740 Whitten Rd Bldg 103 Memphis, TN 38133 Telephone 901-380-9290 Email Bwilliams@Dieselcare.net
Fuel Injection Pump Replacement REMOVAL Diesel Care & Performance Inc 1. Disconnect negative battery terminal. 2. Remove throttle linkage. Fuel Injection Pump Bracket 3. Remove injection pump bracket.
More informationBall valve C 16 valve ball completely moulded in place, extremely low clearance volume, high k v value
Ball valve C valve ball completely moulded in place, extremely low clearance volume, high k v value Advantage maximum safety due to valve ball completely moulded in place - ball and ball seat cannot be
More information4/2-Way Pneumatic Solenoid Valve
4/2-Way Pneumatic Solenoid Valve Robust servo assisted piston valve Service friendly manual override Single or block assembly Explosion-proof versions Type 5413 cam be combined with Type 2508 Cable plug
More informationP2/P3 Series Piston Pumps Variable Displacement zp09. Catalog HY28-2662-CD/US
P2/P3 Series Piston Pumps Variable Displacement zp9 Catalog HY28-2662-CD/US A3 Series P2/P3 A4 General Information General Information Series P2/P3 P2 Series The newly developed variable displacement piston
More informationDirectional seated valves type VP 1
Directional seated valves type VP 1 zero leakage, intended for general hydraulic applications and grease lubing systems Flow Q max Operation pressure p max = 15 lpm = 400 bar Individual valve Individual
More informationMAKE OF AUTOMOBILE: NUMBER : 076/0800901 DATE : 2008-12-08 Copyright Prins Autogassystemen B.V. 2008 VERSION NR : 2008-10-24 B
MAKE OF AUTOMOBILE: HONDA TYPE: CIVIC PISTON DISPLACEMENT: 1800 NUMBER OF VALVES: 16 ENGINE NUMBER: R18A TYPE VSI INJECTOR ( COLOR ) ORANGE MODEL YEAR: 2008 ENGINE SET NUMBER 348/0250200.07 NUMBER : 076/0800901
More informationPTO OWNER S MANUAL ALLISON FAMILY CODE. pag.1
PTO OWNER S MANUAL FAMILY CODE ALLISON pag.1 CONTENTS GENERAL INFORMATION Safety information...3 OMFB P.T.O. Safety Label Instructions...6 Foreword...7 INSTALLATION INSTRUCTIONS Mounting the PTO on the
More informationRotary actuator for 2 and 3-way (control) ball valves Torque 5 Nm Nominal voltage AC 100... 240 V Control: Open/close or 3-point Auxiliary switch
echnical data sheet Rotary actuator LR-S Rotary actuator for and -way (control) ball valves orque 5 Nm Nominal voltage C... 4 V Control: Open/close or -point uxiliary switch echnical data Electrical data
More information0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N
55 Series - General purpose relays 7-10 A Features 55.12 55.13 55.14 Printed circuit mount, general purpose 2, 3 & 4 Pole relays 55.12-2 Pole 10 A 55.13-3 Pole 10 A 55.14-4 Pole 7 A AC coils & DC coils
More informationGuide rail bracket (for adjustable heads)
(for adjustable heads) Part. 209 40 ø,5 ø10,5 2 2,5 115 15 42 5 11 37 72 4 70 Code 209 / 0754 MATERIALS: Bracket made out of reinforced polyamide black colour. FEATURES: To be used with heads Part.221,
More informationPDP and SD Series Pump Station
PDP and SD Series Pump Station 1 THE COMPANY SEIM, after 35 years of production, have achieved a leading position in the screw pump market world wide. Our high volume production of market leading products(more
More informationCooling system components, removing and installing
Engine BHW Cooling system components, removing and installing Page 1 / 24 19-1 Cooling system components, removing and installing Warning! When doing any repair work, especially in the engine compartment,
More informationQPM3 Low pressure pump for circulation of oil in hydraulic and lubricating systems
The Professional Choice in Fluid Management QPM3 Low pressure pump for circulation of oil in hydraulic and lubricating systems The Olaer Group is a global player specialising in innovative, efficient system
More informationPVM Piston Pumps Service Manual
PVM Piston Pumps Service Manual PVM018/020 PVM045/050 PVM057/063 PVM074/081 PVM098/106 PVM131/141 Table of Contents Service Parts Pump Description... 3 Basic pump Pump Operation Controls Types Part Identification...
More informationHeating, air-conditioning, cooling
Series description Design High efficiency, single stage, low pressure, inline centrifugal pump Supplied with EC motor and electronic duty adaptation Available in glanded construction, mechanical shaft
More informationHigh Pressure Gear Motors KM 1
High Pressure Gear Motors KM 1 2 KRACHT GmbH Gewerbestr. 2 58791 Werdohl, Germany fon +49()23 92/935- fax +49()23 92/935 29 mail info@kracht.eu web www.kracht.eu Construction 1 5 8 9 1 2 6 4 7 3 1 Housing
More informationSINGLE LINE CRENTRALIZED LUBRICATION SYSTEM
SINGLE LINE CRENTRALIZED LUBRICATION SYSTEM Volumetric SYSTEM 1 Ph +39 0331 601697 Fax +39 0331 365149 - www.ilclube.com - info@ilclube.it VOLUMETRIC SYSTEM INDEX INTRODUCTION 4-5 MANUAL PUMPS PRD-13 6-7
More informationPRODUCT CARD GEAR PUMPS AND MOTORS ORS GROUP 3 E0.17.0703.02.01 TM GEAR PUMPS AND MOTORS INDEX Page 1 - GENERAL INDEX Page 2 - Features - Quick guide Page 3 - Features - General - Working conditions -
More informationKTZ32.2-51. data sheet parts list exploded view dimensional drawing sectional drawing performance curve. parts list as Excel-spreadsheet
KTZ32.2-5 data sheet parts list exploded view dimensional drawing sectional drawing performance curve parts list as Excel-spreadsheet Heltorfer Str.6 40472 Düsseldorf Germany Tel.: +49-2-479373 Fax: +49-2-479429
More informationPressure Relief Valves SPV, SPVF
Pressure Relief Valves SPV, SPVF Construction of the Pressure Relief Valves SPV, SPVF Symbol Description The direct spring, sliding piston Pressure Relief Valve SPV/SPVF is intended for inline mounting
More informationcompressed air conditioning accessories. one stop shop process reliable efficient economical high degree of reusability
Screwdriving technology Automation Air motors Air tools compressed air conditioning and accessories one stop shop process reliable efficient economical high degree of reusability DEPRAG offers a comprehensive
More informationProcurement Specification for a High Security Lift Arm Barrier (HSLAB) EB950 CR Armstrong High Security Lift Arm Barrier
Procurement Specification for a High Security Lift Arm Barrier (HSLAB) EB950 CR Armstrong High Security Lift Arm Barrier A. Requirement This document is to be used to specify the physical and operational
More informationSpecifications for Volkswagen Industrial Engine
Volkswagen 1 industrial engine Specifications for Volkswagen Industrial Engine AFD 1.9 ltr. TDI diesel engine EURO 2 Volkswagen AG, Wolfsburg Volkswagen AG reserves the right to introduce amendments or
More informationSafety for Hydraulics Leak free double check valve, pilot operated, series DERV Cartridge type, two stage
Safety for Hydraulics Leak free double check valve, pilot operated, series Cartridge type, two stage 8 1 1 General description spring closed, pilot operated, cartridge type poppet valve it holds the load
More informationHG600/HG800. Hydro-Power Unit. Installation and Operation Guide
HG600/HG800 Hydro-Power Unit Installation and Operation Guide Copyright 04 HydroSpin, All rights reserved. The data contained in this document is proprietary to HydroSpin. It is disclosed to the receiving
More informationTECHNICAL INFORMATION
TECHNICAL INFORMATION Models No. 2012NB Description 304mm (12") Automatic Thickness Planer CONCEPTION AND MAIN APPLICATIONS * Compact and light weight (27 Kg./59 lbs) automatic thickness planer for easier
More informationOUT. The SF2 series suction filter are designed for reservoir side-wall applications. This completely new design of filter allows the filter
D e s c r i p t i o n 250 The SF2 series suction filter are designed for reservoir side-wall applications. This completely new design of filter allows the filter within the filter preventing oil loss from
More informationConlift1, Conlift2, Conlift2 ph+
GRUNDFOS DATA BOOKLET Conlift1, Conlift2, Conlift2 ph+ Small lifting stations 50 Hz CONLIFT1, CONLIFT2, CONLIFT2 ph+ Table of contents 1. Product overview 3 Conlift for condensate applications 3 Applications
More informationVickers. Piston Pumps
Vickers Piston Pumps xial Piston Pumps Fixed and Variable Displacement PF, PF, PF PV /6, PV /, PV /9, PV and PV 9 to SE PV /6, PV /, PV /9 to DIN/ISO 39, Part G-379 Contents asic characteristicts..........................................................................................3
More informationSystem 8. ü www.nassmagnet.com ( +49 511 6746-0. System 8
System 8 ü www.nassmagnet.com ( +9 11 7-0 System 8 The name System 8 stands for a modular system of solenoid coils, armature systems, solenoid operators and solenoid valves. The diameter of the armatures
More informationDuplex Filters 40/160 LD 0003-0045 40/160 LDN 0040-0400. Industrial Filters Accumulators. Filters for inline installation for continuous operation
Industrial Filters Accumulators Duplex Filters 40/160 LD 0003-0045 40/160 LDN 0040-0400 Filters for inline installation for continuous operation With integrated pressure equalisation valve Optimised flow
More informationChapter 6: Check Valves
Contents Chapter : Check Valves Series Description Size Mounting Page Parker Standard DIN / ISO 1/8 1/4 3/8 1/2 3/4 1 0 10 1 25 32 Shuttle valves SSR -2 Check valves, direct operated RK / R CS SPZE SPV
More information