2011 DC Electropumps Bull. Rotation Ø 15 6,45 3,5 5,7

Save this PDF as:
 WORD  PNG  TXT  JPG

Size: px
Start display at page:

Download "2011 DC Electropumps Bull. Rotation Ø 15 6,45 3,5 5,7"

Transcription

1 Ø 5 ±. DC Electropumps Bull,5 Rotation,5 5,7

2 Fax B... Electro pumps Bull series MODEL CODE EPB,5 DC /S5 K, V** Electro Pump Bull series Gear pump displacement (cc/rev (see tables E..: Dc electric motor power (kw and type (see tables E..:,5 DC (/T/S:,5kW VDC (/thermal switch/start switch,5 DC (/T/S:,5kW VDC (/thermal switch/start switch,5 DC (/T/S:,5kW VDC (/thermal switch/start switch,5 DC (/T/S:,5kW VDC (/thermal switch/start switch, DC (/T/S:,kW VDC (/thermal switch/start switch, DC (/T/S:,kW VDC (/thermal switch/start switch Optional Starting Switch: (see tables E..: /S5: 5 A starting switch (for Ø motors Optional Relief Valve (see tables E..: V bar V bar V5 5 bar V5 7 5 bar K,, K,, K,, K,, K,,7 K,, K,, K,, K,7,7 K,, B...

3 Fax B... Electro pumps Bull series Option: foot mounting MODEL CODE EPB, DC /S5 K, V** Electro Pump Bull series E5 Option: foot mounting Gear pump displacement (cc/rev (see tables E..: Dc electric motor power (kw and type (see tables E..:, DC (/T/S:,kW VDC (/thermal switch/start switch, DC (/T/S:,kW VDC (/thermal switch/start switch, DC (/T/S:,kW VDC (/thermal switch/start switch Optional Starting Switch: (see tables E..: /S5: 5 A starting switch (for Ø motors Optional Relief Valve (see tables E..: V bar V bar V5 5 bar V5 7 5 bar K,,7 K,, K,, K,, K,7,7 K,, K,7, K,, K5,, K,, K7,, B...

4 Fax B... Electro pumps Bull 5 series Option: foot mounting MODEL CODE EPB5, DC /S K,7 V** Electro Pump Bull 5 series E5 Option: foot mounting Gear pump displacement (cc/rev (see tables E..: Dc electric motor power (kw and type (see tables E..:, DC (/T/S:,kW VDC (/thermal switch/start switch, DC (/T/S:,kW VDC (/thermal switch/start switch Optional Starting Switch: (see tables E..: /S: A starting switch (for Ø 5 motors Optional Relief Valve (see tables E..: V bar V bar V5 5 bar V5 7 5 bar K,,7 K,, K,, K,, K,7,7 K,, K,7, K,, K5,, K,, K7,, B...

5 Fax B... Electro pumps Bull 5 series MODEL CODE EPB5,HD DC /S K, V** Electro Pump Bull 5 series E5 Option: foot mounting Gear pump displacement (cc/rev (see tables E..: Dc electric motor power (kw and type (see tables E..:,5HD DC (/T/S:,5kW VDC (/thermal switch/start switch,hd DC (/T/S:,kW VDC (/thermal switch/start switch,hd DC (/T/S:,kW VDC (/thermal switch/start switch Optional Starting Switch: (see tables E..: /S: A starting switch (for Ø 5 motors Optional Relief Valve (see tables E..: V bar V bar V5 5 bar V5 7 5 bar K,,7 K,, K,, K,, K,7,7 K,, K,7, K,, K5,, K,, K7,, B...

6 Fax B... EPB DC motors Starting switch option 5 5,5,5 Protection degree: IP5 Insulation class: F M,5 Ø Thermal protection option Ø,5 Ø Ø7,5,5 Rotation Weight:, kg Permanent magnets Code Nominal duty cycle 5W V DC motor,5 DC MCS5 5W V DC motor,5 DC MCS5 W V DC motor, DC MCS W V DC motor, DC MCS 5W V DC motor with thermal protection,5 DC/T MCST 5W V DC motor with thermal protection,5 DC/T MCST 5W V DC motor with thermal protection,5 DC/T MCST5 5W V DC motor with thermal protection,5 DC/T MCST5 W V DC motor with thermal protection, DC/T MCST W V DC motor with thermal protection, DC/T MCST S: min : % ED S: min : % ED S: min : % ED S: min : % ED S: min : 5% ED S: min : 5% ED S: min : % ED S: min : % ED S: min : % ED S: min : % ED Nominal Nominal speed current rpm A rpm 5 A rpm A rpm A rpm A rpm 5 A rpm A rpm 5 A rpm A rpm A Options or V DC 5 Amp start switch mounting kit Remote wired control with two buttons and m cable (see U.. S5 DC S5 DC P M7SC M7SK (V DC M7SC M7SK(V DC P (single acting P P (double acting Notes: the starting switch mounting kit is provided when specifying the /S5 in EPB. When ordering spare starting switches, it must be ordered separately (code: M7SK. Coupling Coupling for Ø DC motors and gr. pump Note: the coupling is already included when specifying the motor in EPB. E7 Flange Flange for Ø DC motors and gr. pump E Note: the flange is already included when specifying the motor in EPB assembly code. B...

7 Fax B... EPB DC motors Starting switch option M Ø Ø Ø, Thermal protection option Ø 5 ±. Rotation,5 Compound wound Protection degree: IP5 Insulation class: F Weight: 7,5 kg 7,5 5,7 Code W V DC motor, DC MCS W V DC motor, DC MCS W V DC motor with thermal protection, DC/T MCST W V DC motor with thermal protection, DC/T MCST W V DC motor with thermal protection, DC/T MCST Nominal duty cycle S: min : 7,5% ED S:,min :,5% ED S: min : 7,5% ED S:,min : 7,5% ED S:,min :,5% ED Nominal Nominal speed current rpm A rpm A rpm A rpm A rpm A Options Starting switch 5A or V DC mounting kit DC motors plastic cover S5 DC S5 DC M7SC M7SK (V DC M7SC M7SK(V DC F F Notes: the starting switch mounting kit is provided when specifying the /S5 in EPB. When ordering spare starting switches, it must be ordered separately (code: M7SK. Coupling Coupling for Ø Ø5 DC motors and gr. pump Note: the coupling is already included when E specifying the motor in EPB. Flange Flange for Ø Ø5 DC motors and gr. pump DC motors plastic cover Note: the flange is already included when specifying E the motor in EPB assembly code. Weight:,7 kg 7 Ø B...

8 Fax B... EPB5 DC motors XM Ø 5 Ø Ø Ø 5 Ø,5 7,5 Compound wound Protection degree: IP Insulation class: F Weight: kg 5,7 Rotation Code W V DC motor with thermal protection & fan, DC/T W V DC motor with thermal protection & fan DC/T Nominal Nominal Nominal duty cycle speed current S: min MCST : 7,5% ED rpm A S: min 5 rpm 7 A MCST : 7,5% ED Spare part code Options Starting switch A or V DC S DC S DC M7ZC (V DC M7ZC (V DC Coupling Coupling for Ø and Ø5 DC motors E Note: the coupling is already included when specifying the motor in EPB. Flange Flange for Ø and Ø5 DC motors E Note: the flange is already included when specifying the motor in EPB. B...

9 Fax B... EPB5 DC motors with fan cooling 5 N 7 M 5 Series wound Protection degree: IP Insulation class: F 5 Ø Ø5 Ø5 Ø j 5 5 Rotation Weight:,5 kg Front attachment: B Code code Spare part code Nominal Nominal Nominal Mounting duty cycle speed current kit 5W V DC motor thermal protection & fan,5hd DC/T MBCST5 S: min 7 rpm A XB W V DC motor thermal protection & fan HD DC/T MBCST S: min 7 rpm 7 A XB W V DC motor thermal protection & fan HD DC/T MBCST S: min rpm A XB Options Starting switch A or V DC S DC S DC M7ZC ( V DC M7ZC ( V DC Coupling Two pieces coupling for Ø 5 DC motors E E Note: the coupling is already included when specifying the motor in EPB. Flange Flange for Ø 5 DC motors E5 Note: the flange is already included when specifying the motor in EPB. Other B DC motors for heavy duty or special applications They are available with Ø5, Ø5 or Ø in multiple executions, engineered to perform heavy duty cycles and tailor made to suit each specific application, with or without fan cooling or thermal protection. They are mounted on the central manifold with B standard mounting kits (see tables U.. and following. To properly choose these motors, following minimum information must be provided to our technical office: motor power and voltage, application type, duty factors: S [min] continuous running time and [%] percentage of running time on total cycle time, required motor speed, 5 quantity to be supplied. B...

10 Fax B..5. DC motors choice and electric connection schemes DC motors choice Once required pressure and flow and available voltage ( or V DC are known, you can select the motor checking on each provided diagram if a pump displacement is available at the intersection of pressure and flow values. On the relevant I curve you obtain the absorbed current. When the intersection point is not exactly on a pump curve, choose the closer pump. On the right hand diagram, from the current value, you can easily obtain the maximum allowed S (min and (% values. S gives the allowable motor continuous running time in minutes, gives the allowable running time in % of the total cycle. If obtained S and values are not enough for required duty cycle, choose a bigger motor and repeat the calculation on the new motor curves.,7,,,,,,,,,,,,, P (bar Electric connection schemes I (A 5 S, 7,7 W V Q (l/min Example: For our application we have following data: flow = l/min, max pressure = bar, not clearly defined duty cycle. We check on, Kw V DC motor diagram and see there is a pump available. We choose from curves, pump: a, cm/rev pump. On the corresponding I curve we read 5 A absorbed current. In these conditions on the S / diagram we read that the DC motor can work for maximum 7 min (S, that is 7% ( of the total cycle, i.e. after 7 min working, the motor should cool down for at least min. The total cycle time is calculated adding the working time and the idle time (7% working time plus % idle time, in this case min. If this duty cycle is not adequate for our application, we must choose a higher power DC motor and check the relevant diagram again. S(min (% White Thermal switch MSV Red Starting switch Red Starting switch Black White Remote control P M Single effect cylinder Black Directional valve Brown Grey (up M Thermal switch Yellow/ Green Black (down Starting switch Remote control P Double effect cylinder M B..5.

11 Fax B... DC motors diagrams EBCS5 5 W V I (A,,,,, 5 5,,,,, 7,,.5 I ( 5 I (, I (,, 7,,.5 I (A EBCS5 5 W V I ( S S,,, , Q (l/min Q (l/min.5 S(min (% P (bar, S(min (% 5 P (bar Test made with battery 5Ah 5% charged at 5 C and mineral oil ISO VG at C,,,, I (,, I,,, (,,, 5, I ( I (,, I (, 7 I (,,, I (, I (, I (A EBCS W V I (A I ( EBCS W V, S,, 5, 5 Q (l/min Q (l/min, S(min 5 (% P (bar,,, 5 5 S, 5 S(min (% P (bar Test made with battery 5Ah 5% charged at 5 C and mineral oil ISO VG at C,, I (,7, 5, I (,,,,7,,,,, I (A,,7, 7, EBCS W V I (A EBCS W V,,, I ( I (, S,,, 5 S,, Q (l/min,, Q (l/min 5,, 5 5 P (bar 5 S(min (%,, P (bar S(min,5 (% 5 7,5,5 5 Test made with battery 5Ah 5% charged at 5 C and mineral oil ISO VG at C B...

12 Fax B..7. DC motors diagrams EBCST W V I (A,,,, I (,, I (A,,,,,,7,,,, 7,,, EBCST W V 5,, 5,, S 5 Q (l/min Q (l/min, 5,,, S,,, 5 S(min (% P (bar P (bar 5 S(min (% 5 Test made with battery 5Ah 5% charged at 5 C and mineral oil ISO VG at C I (A, S 5 Q (l/min Q (l/min S,,,,7 5 5,, 5 I (,,, 5, I (,,,,, 5 7, I (, I (,,7,,, I (, 7,,,, I ( I (,,,, I (A EBCST5 5 W V HD EBCST W V 5 5 S(min P (bar (% 5,, P (bar S(min (% 5 5 5,,, I (7,, 7,, I (7,,,, I (A 7,, EBCST W V HD 7,, I (A, EBCST W V HD Test made with battery 5Ah 5% charged at 5 C and mineral oil ISO VG at C, 7,, 5 S 5 Q (l/min,, 5 P (bar 5,7 S(min 5 (% 5 5, 5 5, S Q (l/min,, P (bar S(min (% Test made with battery 5Ah 5% charged at 5 C and mineral oil ISO VG at C B..7.

13 Fax B... Gr. gear pumps 5 n. Ø 5,5 5,5, Ø 55 Ø N / BSPP,5 5 Alluminium adapter flange for group Code: E55 n. Ø,5 n. M5 Weight:, Kg field E5 ** ** K Size: see spare part code on below table Pump type: K = K type with front/rear ports KL = KL type with lateral ports Nominal displacement: (cc/rev see below table, Ports: = front/rear ports = lateral ports Available range Nominal Peak Intermittent Continuous Max speed N Displacement pressure pressure pressure (rpm (mm (cc/rev (bar (bar (bar Bolts* (mm Spare part code Weight, 5,5 M5x55 E5, Kg 7,5 M5x55 E5,5 Kg 5,5 M5x E5, Kg,,, 5 5,5 M5x5 E, Kg, 55,5 M5x5 E, Kg,5 57, M5x7 E5,5 Kg Other pumps executions with different pressure/speed ratings are available on request. * A proper washer is to be forecast to adapt bolt lenght Main features Oil temperature Inlet pressure Fixing bolts 5 C,7 < P <, bar (absolute pressure x M. class steel tightening torque: 5 Nm Peak pressure: cycle s ON Pressure definition Intermittent pressure: cycle s ON Continuous pressure: cycle always ON Filtration setting 5 5 µ B...

14 Fax B... Gr. gear pumps 5 N,5 Ø 7 Ø n. Ø, Option: relief valve / BSPP (KL type field E ** ** K Size: see spare part code on below table Pump type: K = K type KL = KL type with lateral ports Nominal displacement: (cc/rev see below table, Ports: = front/rear ports = lateral ports Optional relief valve: (bar see table E.. V** Available range Nominal Peak Intermittent Continuous Max speed N Displacement pressure pressure pressure (rpm (mm (cc/rev (bar (bar (bar Bolts* (mm Spare part code Weight, 5 5 Mx Mx75 E** E**,77 Kg,, 5 5 Mx75 E**5, Kg, 5 5 Mx, Kg, 5 5 Mx E** E**5, Mx5 E**,7 Kg,7 7 Mx5 E**7, Kg, 7 Mx E**, Kg 7 7 Mx E**,5 Kg Mx E** Kg,,,77 Kg,5 Kg Other pumps executions with different pressure/speed ratings are available on request. * Proper washers are to be forecast to adapt bolt lenght Main features Oil temperature Inlet pressure Fixing bolts 5 C,7 < P <, bar (absolute pressure x M. class steel tightening torque: 5 Nm Peak pressure: cycle s ON Pressure definition Intermittent pressure: cycle s ON Continuous pressure: cycle always ON Filtration setting 5 5 µ B...

15 Fax B... Accessories VMDC 5,5 max ø 5 ø,7 / UNF A,5 P T Hex. Hex. Hex. Hydraulic symbol P VMDC Direct acting relief valve Nominal size: = l/min B Working range: A = bar B = bar C = 5 bar D = 7 5 bar Main features Adjusting device: = screw (std = handwheel Series T Max pressure 5 bar Max flow l/min Weight,5 kg Recommended tightening torque: Nm Recommended filtration settings: 5 5 µ Oil temperature: C Foot mounting support E5 Weight:, Kg 5 Ø,5 n. ø n. s E5 B...

2011 AC & DC Hydraulic Power Packs Micro

2011 AC & DC Hydraulic Power Packs Micro AC & DC Hydraulic Power Packs Micro POWER PACKS MICRO series ordering code PPM/- QUICK SELECTION GUIDE AC & DC electric motors DC motors,5 DC_T VDC motor - 5W - Ø 8 + thermal switch,5 4DC_T 4VDC motor

More information

2011 AC & DC Hydraulic Power Packs Compact

2011 AC & DC Hydraulic Power Packs Compact 11 C & DC Hydraulic ower acks Compact OWER CKS COMCT series ordering code C11/-1 QUICK SELECTION GUIDE C & DC electric motors DC motors Section,15 1DC_T 1VDC motor - 15W - Ø 8 + thermal switch,15 4DC_T

More information

HYDAC Compact Power Units CA

HYDAC Compact Power Units CA 1007 HYDAC Compact Power Units CA Up to 250 bar Up to 12.6 l/min Suitable for: Short-term operation S2 Intermittent operation S3 1. TECHNICAL SPECIFICATIONS 1.1 GENERAL For short-term operation S2 or intermittent

More information

VARIABLE VANE PUMPS V3

VARIABLE VANE PUMPS V3 VARIABLE VANE PUMPS V3 (series 30 and 40) Nominal sizes 12; 25; 40; 63 up to p n 100 bar V g 8.5; 19; 32; 47 cm 3 /rev KE 1015 11/02 replaces 07/97 easy commissioning due to automatic bleed facility low

More information

Pressure relief valves type AGAM two stage, subplate mounting - ISO 6264 size 10, 20 and 32

Pressure relief valves type AGAM two stage, subplate mounting - ISO 6264 size 10, 20 and 32 www.atos.com Table C06619/E Pressure relief valves type AGAM two stage, subplate mounting ISO 6264 size 10, 20 and 32 1 MODEL CODE AGAM10/11...E AGAM20/.../V AGAM are two stage pressure relief valves with

More information

Series TMM Axial Piston Motor. Technical Information

Series TMM Axial Piston Motor. Technical Information Series TMM Axial Piston Motor Technical Information General Description GENERAL DESCRIPTION These motors are designed primarily to be combined with other products in closed circuit systems to transfer

More information

3/2- and 2/2-way cartridge valve type BVE

3/2- and 2/2-way cartridge valve type BVE 3/2- and 2/2-way cartridge valve type BVE for any flow direction, zero leakage, all ports pressure resistant Flow Q max = 70 lpm Perm. pressure p max = 400 bar Additional valves with same function: ' Type

More information

SOLENOID VALVES 3-4 WAY

SOLENOID VALVES 3-4 WAY SOLENOID VLVES - WY IE/C// CT: FP/VCR Page: 7 SHEET: / SOLENOID VLVES - - WY CV SOLENOID VLVES -WY/-POSITION /- UNF.7 5.7 The electric valve is a -way -position directional electrically controlled Slight

More information

Custom configuration such as modified angle dimensions, other flange standards, 3-way function, alternative materials.are available on request.

Custom configuration such as modified angle dimensions, other flange standards, 3-way function, alternative materials.are available on request. LEAKVALVE: HIGHLIGHTS The core of this valve is a diaphragm in stainless steel 316L, gold plated. Robust, it cannot be damaged with any normal methods. The dead volume is kept as small as possible. There

More information

Proportional relief valves type AGMZO-TERS, AERS two stage, with integral or remote pressure transducer, ISO 6264 size 10, 20 and 32

Proportional relief valves type AGMZO-TERS, AERS two stage, with integral or remote pressure transducer, ISO 6264 size 10, 20 and 32 www.atos.com Table F040-1/E Proportional relief valves type AGMZO-TERS, AERS two stage, with integral or remote pressure transducer, ISO 6264 size 10, 20 and 32 AGMZO are two stage poppet type proportional

More information

Volkswagen New Beetle 2.0 Liter 4-cyl General, Engine (Engine Code AEG) 17 Engine-Lubrication system (Page GR-17)

Volkswagen New Beetle 2.0 Liter 4-cyl General, Engine (Engine Code AEG) 17 Engine-Lubrication system (Page GR-17) 17 Engine-Lubrication system (Page GR-17) Lubrication system components, removing and installing Oil pan, removing and installing Oil pressure and oil pressure switch, checking Dynamic oil pressure warning

More information

Pressure relief valves type ARAM two stage, in line mounting - G 3/4" and G 1 1 /4" threaded ports

Pressure relief valves type ARAM two stage, in line mounting - G 3/4 and G 1 1 /4 threaded ports www.atos.com Table C04520/E Pressure relief valves type ARAM two stage, in line mounting G 3/4" and G 1 1 /4" threaded ports ARAM20/20...E ARAM32.../V ARAM are two stage pressure relief valves with balanced

More information

PRODUCT CARD GEAR PUMPS AND MOTORS ORS GROUP 1 E0.14.0503.02.01 TM GEAR PUMPS AND MOTORS GROUP 1 INDEX Page 1 - GENERAL INDEX Page 2 - Features - Quick guide Page 3 - Features - General - Working conditions

More information

PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES

PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES BUSHING WITH PLUG CONNECTION WITH OUTER CONE PPS CHARACTERISTICS The PPS bushing can be used as a fixed section for the entry of medium

More information

High Pressure Gear Pumps KP 0

High Pressure Gear Pumps KP 0 High Pressure Gear Pumps KP 0 2 KRACHT GmbH Gewerbestr. 20 58791 Werdohl, Germany fon +49(0)23 92/935-0 fax +49(0)23 92/935 209 mail info@kracht.eu web www.kracht.eu Construction According to its design,

More information

Hydraulic Control Solutions

Hydraulic Control Solutions Hydraulic Control Solutions Vexve s Hydrox hydraulic control solutions are suitable for even the most challenging installation sites and conditions. Specifically designed for district heating and district

More information

Line-Mounted Valves L Series

Line-Mounted Valves L Series Spare Part Kit for Valve Series B1LSAD3 Line-Mounted L Series Accessories Spare Part Kits All Series Valve Series B1LSAD3 40.1609 Incl. O-rings, gaskets, spring or muffl er Spare Part Kit for Valve Series

More information

Pressure relief valves Size 6

Pressure relief valves Size 6 Pressure relief valves Size 6 direct controlled Interface to DIN 24 340 and ISO 6264 PN [p max. ] = bar 750400.06.0.06 Description (standard units) Design The pressure relief valves of Type D B C 6 are

More information

2-Way heavy duty flow control, with pressure compensated, solenoid and load sensing controlled priority flow

2-Way heavy duty flow control, with pressure compensated, solenoid and load sensing controlled priority flow 2-Way heavy duty flow control, with pressure compensated, solenoid and load sensing controlled priority flow RE 18309-64/04.10 1/6 Replaces: RE 00171/02.07 A-VRFC2C-VEI-VS-LS 0M.28.03.80 - Y - Z Description

More information

VSNG6 SOLENOID OPERATED DIRECTIONAL CONTROL VALVE COMPACT SIZE

VSNG6 SOLENOID OPERATED DIRECTIONAL CONTROL VALVE COMPACT SIZE VSNG6 SOLENOID OPERATED DIRECTIONAL CONTROL VALVE COMPACT SIZE NFPA D03 MOUNTING INTERFACE ISO 4401-03-02-0-94 (CETOP 4.2-4-03-250) SUBPLATE MOUNTING NFPA D03 ISO 4401-03 (CETOP 03) NG6 Pressure max 4060

More information

Variable Displacement Pump AA10VSO

Variable Displacement Pump AA10VSO Variable Displacement Pump AA10VSO Series 31, Industrial Model, for Open Circuits Axial piston, swashplate design Brueninghaus Hydromatik Sizes 28...140 Nominal pressure 4000 psi Peak pressure 5100 psi

More information

Pump-Transfer Cooler Filtration Unit UKF

Pump-Transfer Cooler Filtration Unit UKF Pump-Transfer Cooler Filtration Unit UKF Symbol General The UKF unit is a compact, easy-to-install system for offline filtration cooling circuits. It consists of a low-noise feed pump, a filter and a plate

More information

Electric Rotary Actuator - On/Off or programmable control actuator

Electric Rotary Actuator - On/Off or programmable control actuator Electric Rotary Actuator - On/Off or programmable control actuator Direct mounting on quarter-turn valves Manual override standard Corrosion resistant Adjustable limit switches Multi-voltage version Type

More information

Cartridge Valves. Solenoid Valves. Vickers. Screw-in Cartridge Valves. Maximum Pressure 210 bar (3000 psi) Maximum Flow 227 l/min (60 USgpm)

Cartridge Valves. Solenoid Valves. Vickers. Screw-in Cartridge Valves. Maximum Pressure 210 bar (3000 psi) Maximum Flow 227 l/min (60 USgpm) Vickers Cartridge Valves Solenoid Valves Screw-in Cartridge Valves Maximum Pressure bar ( psi) Maximum Flow 7 l/min (6 USgpm) Rev /99 77 Introduction For over seventy years, Vickers has provided its customers

More information

A10VSO Nominal size 18 see RD 92712 A10VSO Nominal size 28...140 see RD 92711

A10VSO Nominal size 18 see RD 92712 A10VSO Nominal size 28...140 see RD 92711 A10VO Nominal size 18 see RD 92712 A10VO Nominal size 28...140 see RD 92711 The variable displacement axial piston pump A10VO in swashplate design was designed for hydrostatic drives in open circuits.

More information

4. Vane Motors. Vane Motors 4-1. Maximum Operating pressure (bar) Maximum Displacement (ml/rev.) Weight. Mounting. Series. (Kg)

4. Vane Motors. Vane Motors 4-1. Maximum Operating pressure (bar) Maximum Displacement (ml/rev.) Weight. Mounting. Series. (Kg) Vane Motors 4. Vane Motors Maximum Operating pressure (bar) Maximum Displacement (ml/rev.) Mounting Weight (Kg) Remarks Page M5F 300 25.0 Special (Fan Drive) 17.5 Fan drive Optional braking valve 4-4 M5

More information

MANTA Piston Distributor for Oil and Fluid Grease

MANTA Piston Distributor for Oil and Fluid Grease MANTA Piston Distributor for Oil and Fluid Grease Function Piston distributors meter out and distribute the oil delivered by an intermittently actuated pump. The quantities of oil for the individual lube

More information

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS 2012/04/19 TECHNICAL SPECIFICATIONS Elite LOADER BOOMS Main boom: rectangular structure 6" x 8" (152 mm x 203 mm) made of high tensile steel Stick boom: rectangular structure 6" x 6" (152 mm x 152 mm)

More information

3-Way heavy duty flow control, with pressure compensated and solenoid controlled priority flow

3-Way heavy duty flow control, with pressure compensated and solenoid controlled priority flow 1/6 RE 18309-3/06.10 Replaces: RE 18309-3/04.10 3-Way heavy duty flow control, with pressure compensated and solenoid controlled priority flow A-VRFC3C-VEI-VS 0M.43.20.80 - Y - Z Description The flow control

More information

GROENEVELD AUTOMATIC GREASING SYSTEMS

GROENEVELD AUTOMATIC GREASING SYSTEMS GROENEVELD AUTOMATIC GREASING SYSTEMS TWIN Parts & Accessories Book Pumps, Fittings, Injectors, Lining, etc. www.groeneveld-group.com 1 TWIN ELECTRICAL Item Part # Description 1 F113966 Switch 24V 2 F122991

More information

Volkswagen Jetta, Golf, GTI 1999, 2000 2.8 Liter VR6 2V Engine Mechanical, Engine Code(s): AFP 17 Engine-Lubrication (Page GR-17)

Volkswagen Jetta, Golf, GTI 1999, 2000 2.8 Liter VR6 2V Engine Mechanical, Engine Code(s): AFP 17 Engine-Lubrication (Page GR-17) 17 Engine-Lubrication (Page GR-17) Lubrication system components, removing and installing Oil filter housing, disassembling and assembling Oil pan, removing and installing Oil pressure and oil pressure

More information

Coreless Spin-on Filters

Coreless Spin-on Filters The Smart Alternative to Spin-on Cans! Features: Parker engineers have developed an innovative alternative to the age old spin-on style can. This new design provides all of the benefits of high efficiency,

More information

Fluid. Flu. Fluid Fluid. uid Power d Power P. Fluid Power P. Fluid Power. Fluid Power Power. d Power. Directional Cetop Valves DCV 03.

Fluid. Flu. Fluid Fluid. uid Power d Power P. Fluid Power P. Fluid Power. Fluid Power Power. d Power. Directional Cetop Valves DCV 03. Catalogue Directional Cetop Valves DCV 03 Power Flu uid Power d Power P wer Power Power Power Power Power d Power Power Power ower Power Power wer Power Power P Power Power Powe d Power Power Power Power

More information

2/2 and 3/2 Way Size 6 Seat Valves

2/2 and 3/2 Way Size 6 Seat Valves 2/2 and 3/2 Way Size 6 Seat Valves Directly operated Interface and subplate dimensions according to DIN 24340 and ISO Line connection port size G 3/8" Cartridge design PN [p max. ] = 315 bar 7501856.06.12.08

More information

Fixed displacement vane pumps

Fixed displacement vane pumps Fixed displacement vane pumps RE 1335/1.5 Replaces: 11.2 1/22 Types PVV and PVQ Nominal sizes 18 to 193 Series 1X Maximum operating pressure 21 bar Maximum displacement 18 to 193 cm 3 Doppelpumpe_d_ Double

More information

PR*SP - PR*SPU - PILOT OPERATED PRESSURE RELIEF VALVE SERIES

PR*SP - PR*SPU - PILOT OPERATED PRESSURE RELIEF VALVE SERIES CONTINENTAL HYDRAULICS PR*SP - PR*SPU PILOT OPERATED PRESSURE RELIEF VALVE SERIES 5505 WEST 123RD STREET SAVAGE, MN 55378-1299 / PH: 952.895.6400 / WWW.CONTINENTALHYDRAULICS.COM POWERFUL PR*SP - PR*SPU

More information

Steering unit. Table of contents. Features RE 11872/05.06. Type LAGL. Frame sizes 500 to 1000 Component series 1X Maximum flow 80 l/min

Steering unit. Table of contents. Features RE 11872/05.06. Type LAGL. Frame sizes 500 to 1000 Component series 1X Maximum flow 80 l/min Steering unit RE 11872/05.06 /10 Type LAGL Frame sizes 500 to 1000 Component series 1X Maximum flow 80 l/min H7375 Table of contents Contents Page Features 1 Ordering code 2 Function, section 3 Device

More information

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES BQ FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES Versatility, power, compactness and low running costs are the main characteristics of B&C vane pumps. All the components subject to wear are contained

More information

Rotary actuators Rotary wing drives Series RAK. Brochure

Rotary actuators Rotary wing drives Series RAK. Brochure Brochure 2 Rotary wing drives, angle of rotation: 30-270 Rotary wing drive, double-acting axis geometry: single 4 Rotary wing drives, angle of rotation: 90-270 Rotary wing drive, double-acting axis geometry:

More information

TTC-IIS Series Up to 11 LPM Free Flow

TTC-IIS Series Up to 11 LPM Free Flow 66 Up to 11 LPM Free Flow Typical Applications Gas Analysis Anesthesia Monitors CO 2 Monitors Patient Monitoring Wound Therapy Urinalysis Trace Detection Medical/Training Mannequins Degassing Product Specifications

More information

SCP 012-130 ISO. Other advantages: SCP 012-130 ISO is a series of piston pumps with a fixed displacement for mobile and stationary hydraulics.

SCP 012-130 ISO. Other advantages: SCP 012-130 ISO is a series of piston pumps with a fixed displacement for mobile and stationary hydraulics. SCP 012-130 ISO is a series of piston pumps with a fixed displacement for mobile and stationary hydraulics. SCP 012-130 ISO covers the entire displacement range 12-130 cmᶟ rev. at a maximum pressure of

More information

E4E PILOT OPERATED DIRECTIONAL CONTROL VALVE WITH ELECTRIC PROPORTIONAL CONTROL SERIES 51

E4E PILOT OPERATED DIRECTIONAL CONTROL VALVE WITH ELECTRIC PROPORTIONAL CONTROL SERIES 51 83 300/100 ED E4E PILOT OPERATED DIRECTIONAL CONTROL VALVE WITH ELECTRIC PROPORTIONAL CONTROL SUBPLATE MOUNTING CETOP P05 p max 250 bar Q max (see specification table) MOUNTING INTERFACE OPERATING PRINCIPLE

More information

D.C. Hydraulic Power Systems

D.C. Hydraulic Power Systems D.C. Hydraulic Power Systems Compact designs, integrated and manifold valve circuits Reference: 500-P-000001-EN-02 Issue: 09.2015 1/96 Contents Page 1 General information... 5 1.1 Introduction... 5 1.2

More information

OMP, OMR, OMH and OMEW Hydraulic Motor A wide range of hydraulic motors

OMP, OMR, OMH and OMEW Hydraulic Motor A wide range of hydraulic motors , OMR, OMH and OMEW A wide range of hydraulic motors Motorer.TIF A WIDE RANGE OF HYDRAULIC MOTORS Sauer-Danfoss is a world leader within production of low speed hydraulic motors with high torque. We can

More information

Single sub-base valve

Single sub-base valve solenoid valves Mini-valves 10 mm Electrical connection... Mounting... Port sizes... Rated temperature... Fluid... Working pressure... Nominal flow... Pneumatic connections Voltage... Power... NC poppet

More information

D.C. Motors. Products and specifications subject to change without notice.

D.C. Motors. Products and specifications subject to change without notice. D.C. Motors Order/Technical Support - Tel: (8) 677-5 / FAX: (8) 677-865 / www.crouzet-usa.com / DC Motors Selection guide Gearbox Speed Torque max (Nm).5. Type of Gearbox 8 8 8. Power usable (w) Torque

More information

Volkswagen New Beetle 2.0 Liter 4-cyl General, Engine (Engine Code AEG) 19 Engine-Cooling system (Page GR-19)

Volkswagen New Beetle 2.0 Liter 4-cyl General, Engine (Engine Code AEG) 19 Engine-Cooling system (Page GR-19) 19 Engine-Cooling system (Page GR-19) Cooling system components, removing and installing Coolant hose connection diagram Coolant pump, removing and installing Cooling system components (body side), removing

More information

Chapter 5: Flow Valves

Chapter 5: Flow Valves Catalogue HY11-300/UK Contents Chapter : Flow Valves Series Description Size Mounting Page Parker Standard DIN / ISO 1/4 3/8 1/2 3/4 1 06 10 16 Throttle valves, manual adjustment MVI -2 NS -4 FS With free

More information

PRODUCTS DC MOTORS BLPM MOTORS AC MOTORS CONTROLLERS

PRODUCTS DC MOTORS BLPM MOTORS AC MOTORS CONTROLLERS D R I V E S Y S T E M S PRODUCTS DC MOTORS BLPM MOTORS AC MOTORS CONTROLLERS The vision of Iskra Avtoelektrika is to be: One of the world's leading manufacturers of electric motors and controllers for

More information

Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS

Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS up to size 381; to PN 0.5; to T = 80 C 1. Description 1.1. General FSA fluid level gauges, FSK fluid level sensors and TS temperature

More information

HERZ-Thermal Actuators

HERZ-Thermal Actuators HERZ-Thermal Actuators Data Sheet 7708-7990, Issue 1011 Dimensions in mm 1 7710 00 1 7710 01 1 7711 18 1 7710 80 1 7710 81 1 7711 80 1 7711 81 1 7990 00 1 7980 00 1 7708 11 1 7708 10 1 7708 23 1 7709 01

More information

VERTICAL MULTISTAGE CENTRIFUGAL ELECTRIC PUMPS

VERTICAL MULTISTAGE CENTRIFUGAL ELECTRIC PUMPS Vertical multistage centrifugal electric pumps stainless steel. APPLICATIONS Treating water Industrial washing systems Heating and air conditioning Water supply and boosting Agriculture Irrigation TECHNICAL

More information

ARB AIR LOCKER Air Operated Locking Differentials

ARB AIR LOCKER Air Operated Locking Differentials CKMTA12 & CKMTA24 On-Board Air Compressor Kit, Maximum Performance Specs: ITEM # QTY DESCRIPTION PART # NOTES 01(a) 2 COMPRESSOR ASSEMBLY (12V) CKM01 1 Voltage 12 Volts (CKMTA12), 24 Volts (CKMTA24) 01(b)

More information

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES BQ FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES Versatility, power, compactness and low running costs are the main characteristics of B&C vane pumps. All the components subject to wear are contained

More information

DUGARD. Machine Tools Since 1939. Dugard 700L Series Heavy Duty CNC Lathes. www.dugard.com

DUGARD. Machine Tools Since 1939. Dugard 700L Series Heavy Duty CNC Lathes. www.dugard.com DUGARD Machine Tools Since 1939 Dugard 700L Series Heavy Duty CNC Lathes www.dugard.com Dugard 700L Heavy Duty CNC Lathe 2000, 3000 or 4000mm bed length Designed for easy and convenient operation The concave

More information

Series PVP Variable Volume Piston Pumps

Series PVP Variable Volume Piston Pumps Series PVP Variable Volume Piston Pumps Catalog HY28-2662-CD/US Revised June, 212 hpm12-1.p65, lw, jk 1 Notes Series PVP hpm12-1.p65, lw, jk 2 Introduction Series PVP Series Sizes 6-14 Phased Out For Reference

More information

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES BQ FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES Versatility, power, compactness and low running costs are the main characteristics of B&C vane pumps. All the components subject to wear are contained

More information

Variable Vane Pump, Direct Controlled PV7...A Series 1X / 2X

Variable Vane Pump, Direct Controlled PV7...A Series 1X / 2X Variable Vane Pump, Direct Controlled PV7...A Series 1X / X RE 1 Issue: 1.1 Replaces: 8.8 Sizes 1 to Maximum pressure 1 bar Displacement volume 1 to cm Features Very short control times Low noise Mounting

More information

Output torques up to 8000 Nm. General features. Protection. External coating. Working temperature range

Output torques up to 8000 Nm. General features. Protection. External coating. Working temperature range Type series booklet 8521.15/2--10 ACTELEC 31 to 800 (BERNARD) 1/4 turn electric actuators (irreversible reducer with multi -turn electric actuator ACTELEC 31: screw -nut kinematics ACTELEC 200 to 800:

More information

High Pressure Gear Pumps KP2/KP3

High Pressure Gear Pumps KP2/KP3 High Pressure Gear Pumps KP2/KP3 2 KRACHT GmbH Gewerbestr. 20 58791 Werdohl, Germany fon +49(0)23 92/935-0 fax +49(0)23 92/935 209 mail info@kracht.eu web www.kracht.eu Construction 1 5 6 2 9 8 4 7 3 1

More information

WE-350 Series ¼ Turn Electric Actuator

WE-350 Series ¼ Turn Electric Actuator WE-350 Series ¼ Turn Electric Actuator Operation and Installation Manual Pg 1 (Rev. 020113) Table of Contents 1.0 General 1.1 Pre-Installation Inspection 1.2 Storage 1.3 Features & General Information

More information

Hydraulic Flow Control Valves

Hydraulic Flow Control Valves Webtec Products Limited Hydraulic Flow Control Valves Quality Hydraulic Components from the Webtec Range CONTENTS DESCRIPTION PAGE No. ILFC Series Fixed Flow Pressure Compensated Control Valve 1 VFC Series

More information

VARIABLE DISPLACEMENT AXIAL PISTON PUMPS. For truck applications

VARIABLE DISPLACEMENT AXIAL PISTON PUMPS. For truck applications VARIABLE DISPLACEMENT AXIAL PISTON PUMPS For truck applications TVP FEATURES Variable displacement axial piston pumps swash plate design ideally suited for open circuit truck applications. The compact

More information

Oildyne. 165 Series Hydraulic Power Units. Pressures to 241 bar (3500 psi) Flows to 5.4 lpm (1.4 gpm)

Oildyne. 165 Series Hydraulic Power Units. Pressures to 241 bar (3500 psi) Flows to 5.4 lpm (1.4 gpm) Oildyne Hydraulic Power Units Pressures to 241 bar (3500 psi) Flows to 5.4 lpm (1.4 gpm) 11 Power Unit Features We are pleased to introduce our new power units. The power units let you put more power where

More information

The SF2 series are designed for reservoir side-wall mounting applications, suitable for flow rates to 850 l/min and filtration from 25 to 250 micron.

The SF2 series are designed for reservoir side-wall mounting applications, suitable for flow rates to 850 l/min and filtration from 25 to 250 micron. D e s c r i p t i o n 500 The SF2 series are designed for reservoir side-wall mounting applications, suitable for flow rates to 850 l/min and filtration from 25 to 250 micron. A major feature of these

More information

Fixed Displacement Motor A4FM

Fixed Displacement Motor A4FM Brueninghaus Hydromatik Series 3, for open and closed circuits axial piston - swashplate design Sizes 22 56 Nominal pressure 400 bar Peak pressure 450 bar RE 900/2.95 RE 900/2.95 replaces 0.90 Fixed displacement

More information

Parts Catalog For Nordco Engine 600047 (JD 4024TF270)

Parts Catalog For Nordco Engine 600047 (JD 4024TF270) POWERTECH-E 2.4L 4024 OEM Diesel Engines and Accessories Parts Catalog For Nordco Engine 600047 (JD 4024TF270) (Rev -, Last Update: 06/07) PARTS ORDERING INSTRUCTIONS John Deere parts may be ordered from

More information

DENISON HYDRAULICS vane pumps - single, double T6G - T67G - T6ZC

DENISON HYDRAULICS vane pumps - single, double T6G - T67G - T6ZC DENISON HYDRAULICS vane pumps - single, double T6G - T67G - T6ZC Publ. 1 - EN0709 - A 01 / 2000 / 2500 / FB Replaces : 1 - EN 084 - B L25-10709 - 1 CONTENTS GENERAL CHARACTERISTICS T67GB T6GC - T6ZC T67GB

More information

Cooling system components, removing and installing

Cooling system components, removing and installing Page 1 of 34 19-1 Cooling system components, removing and installing WARNING! The cooling system is pressurized when the engine is warm. When opening the expansion tank, wear gloves and other appropriate

More information

Sensors. Sensors. All Cylinders. Specifications. Features: Features Type REED HALL EFFECT NPN or PNP. Ø8mm - 125mm

Sensors. Sensors. All Cylinders. Specifications. Features: Features Type REED HALL EFFECT NPN or PNP. Ø8mm - 125mm Specifications Features Type REED HALL EFFECT NPN or PNP Applicable Series Configurations Construction Materials Body Mounting Bracket Cable Characteristics Operating Temperature Accuracy All Cylinders

More information

POSEIDON 2-29, 2-25 & 2-22 POSEIDON 2-29, 2-25 & 2-22 XT

POSEIDON 2-29, 2-25 & 2-22 POSEIDON 2-29, 2-25 & 2-22 XT POSEION 2-29, 2-25 & 2-22 POSEION 2-29, 2-25 & 2-22 XT Repair Manual Index A. Safety precautions 3 B. Technical data 4 C. Structure 5-6. Service / Repair 7-23 E. Tools 24 F. Function 25-26 G. Electric

More information

ABLOY EL614 Motor lock with bolt Abloy Oy An ASSA ABLOY Group company EL614 42/52 25/35 25 22 263.5 225 38.2 17.3 3 10 2 Contents TECHNICAL DATA... 4 INSTALLATION... 5 WIRING DIAGRAM... 6 DRILLING SCHEME...

More information

Rexroth Hydraulics. Vane pumps, direct controlled Type PV7...A RE 10 520/10.97

Rexroth Hydraulics. Vane pumps, direct controlled Type PV7...A RE 10 520/10.97 RE 1 52/1.97 Replaces: 12.95 Vane pumps, direct controlled Type PV7...A Nominal sizes 1 to 25 Series 1X Maximum operating pressure 1 bar Displacements from 1 to 25 cm 3 H/A 4617/95 Type PV7-1X/..RA1MA-...

More information

Ball valve C 16 valve ball completely moulded in place, extremely low clearance volume, high k v value

Ball valve C 16 valve ball completely moulded in place, extremely low clearance volume, high k v value Ball valve C valve ball completely moulded in place, extremely low clearance volume, high k v value Advantage maximum safety due to valve ball completely moulded in place - ball and ball seat cannot be

More information

4/2-Way Pneumatic Solenoid Valve

4/2-Way Pneumatic Solenoid Valve 4/2-Way Pneumatic Solenoid Valve Robust servo assisted piston valve Service friendly manual override Single or block assembly Explosion-proof versions Type 5413 cam be combined with Type 2508 Cable plug

More information

Diesel Generating Set

Diesel Generating Set MODEL Standby Power(50Hz) Prime Power(50Hz) 44KW /55KVA 40KW /50KVA Standard Features General Features: Engine( DCEC Cummins 4BTA3.9 -G) Radiator 40 O C max,fans are driven by belt, with safety guard 24V

More information

Eurovacuum EV Series. Single Stage Oil Sealed Rotary Vane Pump

Eurovacuum EV Series. Single Stage Oil Sealed Rotary Vane Pump Eurovacuum EV Series Single Stage Oil Sealed Rotary Vane Pump Eurovacuum EV Series Single Stage Oil Sealed Rotary Vane Pumps Eurovacuum Company is offering its various products to meet industrial vacuum

More information

TECHNICAL INFORMATION

TECHNICAL INFORMATION TECHNICAL INFORMATION P 1 / 5 Model No. Description 8390D Cordless Percussion Driver Drill 13mm CONCEPT AND MAIN APPLICATIONS Model 8390D has been developed by adding percussion mechanism to Model 6390D.

More information

Hydraulic Pump/Motor Division. John Duba Product Manager Piston Pumps. Hydraulic Pump/Motor Division

Hydraulic Pump/Motor Division. John Duba Product Manager Piston Pumps. Hydraulic Pump/Motor Division John Duba Product Manager Piston Pumps Otsego Core Competency... Piston Pumps PAVC Series : 4 displacements from 33-100 cc/r, 207 Bar, 3000 RPM PVP Series : 9 displacements from 16-140 cc/r, 250 Bar, 3000

More information

Directional seated valves type VP 1

Directional seated valves type VP 1 Directional seated valves type VP 1 zero leakage, intended for general hydraulic applications and grease lubing systems Flow Q max Operation pressure p max = 15 lpm = 400 bar Individual valve Individual

More information

Tool Turrets and Tool Discs

Tool Turrets and Tool Discs Our other products Automatic Tool Changer Chucking Cylinders Tool Discs Indexing Tables Tool Turrets and Tool Discs Pragati Automation Pvt. Ltd. 1, IV Phase, 11th Cross, Peenya Industrial Area Bangalore

More information

DXPE*J 85 320/215 ED. DIRECtIONAL CONtROL VALVE PILOt OPERAtED, WItH OBE AND FEEDBACK. Q max (see performance table) SERIES 30

DXPE*J 85 320/215 ED. DIRECtIONAL CONtROL VALVE PILOt OPERAtED, WItH OBE AND FEEDBACK. Q max (see performance table) SERIES 30 85 320/215 ED DXPE*J DIRECtIONAL CONtROL VALVE PILOt OPERAtED, WItH OBE AND FEEDBACK SUBPLAtE MOUNtINg DXPE5J CEtOP P05 DXPE5RJ ISO 4401-05 (CETOP R05) DXPE7J ISO 4401-07 (CETOP 07) DXPE8J ISO 4401-08

More information

Hydraulic Pressure Control Valves

Hydraulic Pressure Control Valves Webtec Products Limited Hydraulic Control Valves Quality Hydraulic Components from the Webtec Range CONTENTS DESCRIPTION PAGE No. RV 020 Direct In-Line Relief Valve 1 RV 025 Relief Valve 3 RV 050 Relief

More information

Piston Pumps. PVE Piston Pumps. Vickers

Piston Pumps. PVE Piston Pumps. Vickers Vickers Piston Pumps PVE Piston Pumps PVE12 Variable Displacement Single Pump PVE19 / PVE21 Variable Displacement Single & Thru-Drive Pumps PVE4* 25V Integrated Models GB C 223 A.1 Table of Contents Introduction.................................................................................................

More information

Pilot-operated Check Valves ERVE. up to 350 bar up to 300 l/min. Cartridge valves E / Connection housings

Pilot-operated Check Valves ERVE. up to 350 bar up to 300 l/min. Cartridge valves E / Connection housings Pilot-operated Check Valves ERVE up to 350 bar up to 300 l/min Cartridge valves Connection housings 1. DESCRIPTION 1.1. GENERAL In accordance with DIN-ISO 1219, HYDAC pilot-operated check valves, type

More information

RPE3-04. Functional Description HA 4014 09/2013. Directional Control Valves Solenoid Operated. Replaces HA 4014 10/2010

RPE3-04. Functional Description HA 4014 09/2013. Directional Control Valves Solenoid Operated. Replaces HA 4014 10/2010 Directional Control Valves Solenoid Operated RPE3-04 Size 04 (D 02) 320 bar (4600 PSI) 30 L/min (8.0 GPM) HA 4014 09/2013 Replaces HA 4014 10/2010 4/3-, 4/2- way directional control valves with solenoid

More information

Extremely compact in size to allow direct flange-mounting on vehicle engine or gearbox PTOs.

Extremely compact in size to allow direct flange-mounting on vehicle engine or gearbox PTOs. TXV - Presentation pumps with Load Sensing control variable displacement piston pumps ADVANTAGES pumps are variable displacement with pressure-flow control called Load Sensing. They self-regulate to give

More information

PLC Line. USER S MANUAL Catalog No Rev. E

PLC Line. USER S MANUAL Catalog No Rev. E PLC Line USER S MANUAL Catalog No. 100125 Rev. E May 2015 Copyright 2015 Intelitek Inc. PLC Line User s Manual Catalog No. 100125 Rev. E May 2015 Every effort has been made to make this technical note

More information

Chain Saws with Chain Brake HPS513CB (45826) and HCS8160CB (45653)

Chain Saws with Chain Brake HPS513CB (45826) and HCS8160CB (45653) SPECIFICATIONS AND PARTS Chain Saws with Chain Brake HPS513CB (45826) and HCS8160CB (45653) Serial Codes GDV and GDL Read and understand all of the instructions and safety information in this manual before

More information

15/40/80CN Series Medium Pressure Filters

15/40/80CN Series Medium Pressure Filters 1/4/8CN Series Medium Pressure Filters Max 32 l/min - 7 bar Global Filtration Technology 1/4/8CN Series TYPICAL APPLICATIONS Compressor Lube Oil Off-line Filter Loops Machine Tools (Automotive Standard)

More information

Series 7500 Torque Sensor

Series 7500 Torque Sensor Properties PTO (Power Take-Off) shaft with integrated torque and angle measurement Non-contact measurement system, high robustness Plug & Play solution, no additional electronics required Performance Measurement

More information

ABLOY DA60 SWING DOOR OPERATOR Installation and commissioning manual Abloy Oy An ASSA ABLOY Group company APPROVALS / STANDARDS Low Voltage directive 7//EEC as amended by the directive 9/68/EEC EMC directive

More information

Heating, air-conditioning, cooling

Heating, air-conditioning, cooling Series description Design High efficiency, single stage, low pressure, inline centrifugal pump Supplied with EC motor and electronic duty adaptation Available in glanded construction, mechanical shaft

More information

The Yachtmans Choice...

The Yachtmans Choice... Ref: 1740, Nov 2015 The Yachtmans Choice... A competitive price 10 to 150 hp, engineered in the UK Advanced, compact, quiet reliable engines Easy engine replacement, with our special feet option Amazing

More information

SIRIUX. SINGLE AND DOUBLE HIGH EFFICIENCY CIRCULATORS Heating Air-conditioning OPERATING LIMITS APPLICATIONS. 28 m 3 /h* Heads up to: Flows up to:

SIRIUX. SINGLE AND DOUBLE HIGH EFFICIENCY CIRCULATORS Heating Air-conditioning OPERATING LIMITS APPLICATIONS. 28 m 3 /h* Heads up to: Flows up to: OPERATING LIMITS Flows up to: m /h* Heads up to: m C Max operating pressure: bars Temperature range: - à + C Max ambient temperature: + C ND of orifices: à * m /h: parallel operation SIRIUX SINGLE AND

More information

Contractors Guide Central Inverter System Installation

Contractors Guide Central Inverter System Installation Contractors Guide Central Inverter System Installation Step By Step Procedures 2,200 Watt/VA 6 Step Installation 1. Mount Bottom Cabinet 2. Mount Top Cabinet 3. Install Batteries 4. Install Conduit 5.

More information

Gear Type Flow Meters VCA/VCN/VCG

Gear Type Flow Meters VCA/VCN/VCG Gear Type Flow Meters VCA/VCN/VCG Function. The gear type flow meters of the type VCA/VCN/VCG are flow meters for liquids with a certain lubri city. The measuring unit of the KRACHT volume counter consists

More information

PRODUCT CARD GEAR PUMPS AND MOTORS ORS GROUP 3 E0.17.0703.02.01 TM GEAR PUMPS AND MOTORS INDEX Page 1 - GENERAL INDEX Page 2 - Features - Quick guide Page 3 - Features - General - Working conditions -

More information

Guide rail bracket (for adjustable heads)

Guide rail bracket (for adjustable heads) (for adjustable heads) Part. 209 40 ø,5 ø10,5 2 2,5 115 15 42 5 11 37 72 4 70 Code 209 / 0754 MATERIALS: Bracket made out of reinforced polyamide black colour. FEATURES: To be used with heads Part.221,

More information

Visions become real. Temperature control and cooling systems. The innovative and reliable solution

Visions become real. Temperature control and cooling systems. The innovative and reliable solution Temperature control and cooling systems The innovative and reliable solution With our PulseTemp equipment you have the option of up to 72 cooling circuits in the impulse cooling, temperature control, temperature

More information