System S 3 cliq seismic resistant. exposed, seismic resistant. OWAlifetime collection

Size: px
Start display at page:

Download "System S 3 cliq seismic resistant. exposed, seismic resistant. OWAlifetime collection"

Transcription

1 System S cliq seismic resistant exposed, seismic resistant OWAlifetime collection

2 System S cliq exposed, seismic resistant The system fulfills the requirements according to ASTM E 0MN-0a, Heavy Duty, according to ASTM C and all requirements according to EN. Stretched hanger wire, gauge (>.0 mm) and of three full turns (0 each) provided by the customer Main tee cliq--mr, slots at 00 mm,. mm or inch Cross tee cliq--ct, length 00 mm, mm or Cross tee cliq--ct, length 00 mm, 0 mm or Wall angle, for example no. / Space bar no., short Space bar no., long Screw or pop by customer Strut no. 0 or CD-Profile 0/ 0. mm by customer 0 Seismic perimeter clip no. spc0 Seismic joint coupling no. sjc0 for cliq--mr Seismic joint coupling no. sjc0 for cliq--ct short Wall perimeter no. /, / mm or similar Modul distance 00 The grid system S cliq fulfills the essential requirements according to ASTM E 0M-0a. The grid system is tested according to ASTM C - and EN by a notified body and ISO 0 certified Lab (LGA Nürnberg TÜV Rheinland, Germany). The tests for the pull out force of the cross tees were carried out with. kn (approx. kg) tension. This system achieved the highest load bearing classification according to ASTM C as Heavy Duty with more than.0 lb/linear feet (. kg/m) for the main tees. These are the essential requirements according to the seismic design categories D, E and F defined in ASTM E 0M-0a. 00 Section dimensions: Main tee cliq--mr Cross tee cliq--ct long / Cross tee cliq--ct short 0 0 < Technical data mineral tiles Edge details Thickness 00 / < 00 Maße 00 x 00 mm, x mm, x, 00 x 00 mm, 0 x mm, x Reaction to fire A-s,d0 in accordance with EN 0- / Class A in accordance with ASTM E Metal suspensions All profiles are zinc galvanized and exposed faces are white painted. For further details please consult our OWAlifetime collection price list < / / 0 / / Suspension depth mm (from underside of soffit). For ease of panel removal 0 mm is recommended. 00 < Approx. mm and 0 mm (OWAcoustic premium)

3 Installation examples (also for module mm and ): Areas m 00 The hanger fixings must be installed according to ASTM E 0M- 00 0a, paragraph... and / / < 00 / Areas > m 00 till m 00 0 / < Additional tasks for areas > m 0 00 / 00 < Lateral force bracings are required for all ceiling areas greater than 000 ft (approx. m ). / < distace: from the wall. m / centres of horizontal restraint points. m 0 / Four -gauge (>.0 mm) wires in all directions secured to the main runner. Angle should not exceed from the 0 plane of the ceiling. A strut must be installed in this area (for example section no. 0, see page ). 00 / 00 / < < / 0 Areas > m 00 < Additional tasks for areas > m < All ceiling areas exceeding 00 ft (approx. m ) must be None 0 separated by a seismic joint, bulkheads braced to structure of full height must partitions be moveable None 0 Separate seismic joints for each type of tees (MT, CT) None 0 None < 00 < 00 < < 00 < 00 < < < 00

4 Cross-section: Section: Wall perimeter: Wall perimeter A / / / / / / / / / / / / / / 0 0 / B Wall perimeter 0 Wall perimeter B / / / / / / / 00 / / 00 / / / / / / 00 / / / / 00 / / 00 For other examples of wall perimeters and installation see OWA-Installation guide no. 0 E and ASTM E 0/E 0M-0a. Wall perimeter A Alternative between wall perimeter B and B and tees with seismic perimeter clip no. spc0 and no. spc B: Cross-section / / / 00 / / 00 / 00 / / / 0 / / / Longitudinal section B: / / / / None None must be moveable None must be moveable No No mu No mu has mu has None fo has mustforc be has to b forc forc force-lo Installation of the seismic perimeter clip: None None must mustbe bemoveable moveable / / The seismic perimeter clip has to be attached by using a hammer.

5 System S cliq exposed, seismic resistant Lateral force bracing for horizontal restraint according to ASTM E 0/E 0M-0a: Type : Type : Lateral force bracing with stretched hanger wire according ot ASTM E 0/E 0M-0a for Type and : < 0 mm. To connect the profiles with the grid-system the The of the CD-Profiles must be lower end has to be notched. 00 / 0 00 / System-related accessories: < 0 < 0 < 0 < < 0 < 0 < 0 < 0 < 0 < 0 < 0 < Top view 0 < 0 < 0 0 seismic joint coupling 0 no. sjc0 and sjc0 (consist of pieces and small components). This but joint has to be suspended on both sides. / 0 0 None. The nut has to be fixed by a locknut. None None must be must moveable. be moveable. The nut The nut has to be has fixed to by be a fixed locknut. by a locknut. 0 seismic perimeter clip None no. spc0, locking of the main None runner and must cross be moveable. tee in the wall The nut area. has to be The fixed nut by a locknut. has to be fixed by a locknut. None must be moveable. The nut has to be fixed by a locknut. None. The nut has to be fixed by a locknut.

6 0 0 / / Material requirements per m (approximations): Dimensions in mm No. 0 Description 00 x 00* 0 cliq--mr Main tee 0. m cliq--ct Cross tee short 0. m cliq--ct Cross tee long. m Stretched hanger wire 0. Stück 0 Strut 0.0 Stück Space bar depending on room size and shape / Wall 00 angle depending on room size and shape / * other dimensions see brochure S cliq / Weight per m : x 00 0 Suspension system approx.. kg/m Tiles mm, appros.. kg/m Light fixtures: OWA can supply compatible light fixtures for this system. 0 For details of performance, installation and fire resistance please see OWA-brochure no. 0 e and OWA- Installation Guide no. 0 E. System description: System S cliq seismic resistant Quality Statement: OWAcoustic mineral panels are free from harmful materials such as asbestos and formaldehyde. A statement from the German institute for Building Technology is available. The mineral wool used in these panels is biodegradable. The criterions of the zero-ranking as a carcinogenic material in the chemical prohibition ordinance ( appendix) section bio-persistent fibres are complied with and therefore carries the RAL-Seal of mineral wool guarantees. Mineral tiles according to EN and DIN : Air Permeability Class pm Formaldehyde FH Class TVOC class TÜV Rheinland LGA Bautechnik GmbH Building Structure Diagnostics Certified acc. to DIN EN ISO 00 TEST CERTIFICATE No. BBMT000/0 Date: Jul nd 00 Purchaser: Odenwald Faserplattenwerk GmbH Dr. Freundt- Strasse Amorbach, Germany Order dated Jul th 00 Object of the Order: Deflection tests / Measuring of tees deflection of a suspended ceiling system Specimen material, or test sample: The test was performed on Jul th 00 The samples were received Jul th 00 Identification: suspended ceiling system consisting of: OWAconstruct main tees, OWAconstruct cross tees OWAconstruct cliq suspended ceiling sections; hangers: Nonius The present certificate contains text sheets and appendix. The certificate results solely refer to the specimen materials/test samples that are stated in the test report. The present certificate can be published in its complete formulation only. Any publishing of its shortened form or of an extract from it is only upon a prior permission by TUEV Rheinland LGA Bautechnik GmbH allowed. BBMT000_0_Prüfzeugnis_Owa_Cliq_E.doc / sheet of TÜV Rheinland LGA Bautechnik GmbH Registered at the Municipal Court of Nuremberg BBMT Tillystraße 0 Nuremberg Nuremberg HRB 0 Ph.: + (0) -00 Fax: + (0) - Managing Directors: Achim Blinne, Hans-Hermann Ueffing bautechnik@de.tuv.com Tax No. //0 VAT ID No. DE Installation: All integrated services should be secured separately. Installation should be carried out in accordance with the information contained in OWA-Installation guide 0 and ASTM E 0M-0a. Installation should be carried out in accordance with the information contained in system leaflet S cliq seismic resistant and OWA-Installation Guide no. 0 E. All components are CE labelled. Component list: OWAconstruct cliq--mr main tee OWAconstruct cliq--ct cross tee short OWAconstruct cliq--ct cross tee long OWAconstruct wall angle no. / OWAconstruct space bar no. OWAconstruct strut no. 0 OWAconstruct perimeter clip no. spc0 OWAconstruct seismic joint coupling no. sjc0 or no. sjc0 None The test must report be moveable. of TÜV The nut Rheinland has to LGA be fixed by a locknut. Bautechnik GmbH shows the tests of the loadbearing capacity and the seismic requirements according to ASTM E 0M-0a Product Warranties The information provided in this leaflet is based on the standards and data available at the time of publication. Any performance, warranties or guarantees provided, expressed or implied, are subject to the exclusive use of OWA components and the installation of those components in accordance with our recommendations. Failure to adhere to these conditions will result in the invalidation of any performance claims, warranties or guarantees and rejection of any liability. OWA reserves the right to make any technical improvements to the products, systems or services without prior notice. All goods and services are supplied in accordance with our current Terms and Conditions of Sale. Errors excepted! Odenwald Faserplattenwerk GmbH Dr.-F.-A.-Freundt-Straße Amorbach tel info@owa.de Brochure S cliq seismic resistant e 000

Our bestsellers THE BASIS FOR SUSTAINABLE INTERIOR DECORATING PROJECTS. OWAlifetime collection

Our bestsellers THE BASIS FOR SUSTAINABLE INTERIOR DECORATING PROJECTS. OWAlifetime collection Our bestsellers THE BASIS FOR SUSTAINABLE INTERIOR DECORATING PROJECTS OWAlifetime collection OWA mineral tiles OWA mineral tiles are manufactured in Germany. They stand for the highest quality and performance

More information

OWAplan1. The seamless acoustic ceiling. Pure acoustics. Pure design.

OWAplan1. The seamless acoustic ceiling. Pure acoustics. Pure design. OWAplan1 The seamless acoustic ceiling. Pure acoustics. Pure design. 3 Perspectives of freedom OWAplan It is time for a new way of thinking, for a new kind of freedom in room design, for taking a different

More information

Ecophon Focus Ds. System range. XL 1800x600. Size, mm. XL 2400x600 T24 Thickness (THK) XL 2000x600. 1200x600 1200x1200 1600x600 M206, M208, M238

Ecophon Focus Ds. System range. XL 1800x600. Size, mm. XL 2400x600 T24 Thickness (THK) XL 2000x600. 1200x600 1200x1200 1600x600 M206, M208, M238 Ecophon Focus Ds For applications where a suspended ceiling with a concealed grid is required, but individual tiles must be easily demountable. Ecophon Focus Ds has a concealed grid and syetrical edge

More information

Create conversation areas

Create conversation areas OWAconsult collection Canopies1 Create conversation areas 2 Canopies Strong Monoliths. Pretty formations. Canto The OWA ceiling canopy is based on the acoustically effective Sinfonia mineral tile (sound

More information

Ecophon Focus A. System range. Size, mm. XL 2000x600. XL 1800x600. XL 2400x600 T15 T24 Thickness (THK) Inst. Diagr. 1200x600 1200x1200 1600x600

Ecophon Focus A. System range. Size, mm. XL 2000x600. XL 1800x600. XL 2400x600 T15 T24 Thickness (THK) Inst. Diagr. 1200x600 1200x1200 1600x600 Ecophon Focus A For applications where a robust suspended ceiling system is required. Ecophon Focus A has an exposed grid system. Each tile is easily demountable. The systems consist of Ecophon Focus A

More information

Ceiling Systems for Special applications

Ceiling Systems for Special applications Ceiling for Special applications OWAcoustic Where you depend on it: Premium ceilings for sensitive areas Healthcare Laboratories Food processing, preparation and retail Areas of sustained high humidity

More information

Standard Practice for Installation of Ceiling Suspension Systems for Acoustical Tile and Lay-in Panels in Areas Subject to Earthquake Ground Motions 1

Standard Practice for Installation of Ceiling Suspension Systems for Acoustical Tile and Lay-in Panels in Areas Subject to Earthquake Ground Motions 1 Designation: E 580/E 580M 09a Standard Practice for Installation of Ceiling Suspension Systems for Acoustical Tile and Lay-in Panels in Areas Subject to Earthquake Ground Motions 1 This standard is issued

More information

HOW TO ESTIMATE THE COST OF T-BAR

HOW TO ESTIMATE THE COST OF T-BAR HOW TO ESTIMATE THE COST OF T-BAR ACOUSTICAL CEILINGS MICHAEL HILL DATE WRITTEN: MAY OF 2007 The author is Michael Hill, Estimator with Kaiser Foundation Hospitals, National Facilities Services Cost Engineering

More information

AMF Line; wall absorbers Wall mounted acoustic designs PERFORMANCE CEILINGS. M ore s c op e f or i n n ovat i on MADE IN GERMANY

AMF Line; wall absorbers Wall mounted acoustic designs PERFORMANCE CEILINGS. M ore s c op e f or i n n ovat i on MADE IN GERMANY PERFORMANCE CEILINGS M ore s c op e f or i n n ovat i on AMF Line; wall absorbers Wall mounted acoustic designs MADE IN GERMANY 138568_Prospekt Wandabsorber_GB int.indd 1 Acoustic elements on the wall

More information

CEILING SYSTEMS. Between us, ideas become reality. Installing. Suspended Ceilings. North America Version

CEILING SYSTEMS. Between us, ideas become reality. Installing. Suspended Ceilings. North America Version CEILING SYSTEMS Between us, ideas become reality Installing Suspended Ceilings North America Version 1 Installing Armstrong Suspended Ceilings An Armstrong suspended mineral fiber ceiling is functional,

More information

ACOUSTICS. Axiom Canopy Clouds Absorption Data Sabines (average 500, 1k, 2k, 4k Hz) ACOUSTICS TESTING DATA Sound Absorption in Sabines

ACOUSTICS. Axiom Canopy Clouds Absorption Data Sabines (average 500, 1k, 2k, 4k Hz) ACOUSTICS TESTING DATA Sound Absorption in Sabines ACOUSTICS ACOUSTICS TESTING DATA Sound Absorption in Sabines SABINE DEFINITION A Sabine is a measure of the sound absorption provided by a material when installed within an architectural space. The number

More information

Partitioning & Ceiling Product Information

Partitioning & Ceiling Product Information Partitioning & Ceiling Product Information tel + 44 (0) 1384 412448 fax + 44 (0) 1384 4494 email enquiries@drywallsteelsections.co.uk web www.drywallsteelsections.co.uk tel + 44 (0) 1384 412448 fax + 44

More information

I n s t allat ion Gu id e

I n s t allat ion Gu id e CEILIN&WLL SYSTEMS etween us, ideas become reality XIOM CIRCLE & CURVED CNOPIES For Tegular 8 mm & MicroLook 8 mm reveal edge tiles I n s t allat ion u id e P R E P R T I O N SUSPENSION POINTS Suspension

More information

MERO Floor Systems - CleanRoom

MERO Floor Systems - CleanRoom MERO Floor Systems - CleanRoom Innovative solutions out of one hand Development Access floor Consulting Hollow floor Planning Floor covering and Manufacturing Installation Installation Services Floor systems

More information

Installation guide for the SafeLine type anchorage device. Tested in compliance with EN 795: 1996. No.: SE-...

Installation guide for the SafeLine type anchorage device. Tested in compliance with EN 795: 1996. No.: SE-... Installation guide for the SafeLine type anchorage device Tested in compliance with EN 795: 1996 No.: SE-... Version: 09.10.2008 SE 67 Subject to technical alterations! Contents 1. General information

More information

CEILING SYSTEMS. CI/SfB (35) Xy April 2006. [Between us, ideas become reality.] ULTIMA CANOPY. Data sheet. Acoustic performance meets High Design

CEILING SYSTEMS. CI/SfB (35) Xy April 2006. [Between us, ideas become reality.] ULTIMA CANOPY. Data sheet. Acoustic performance meets High Design CEILING SYSTEMS [Between us, ideas become reality.] CI/SfB (35) Xy April 2006 ULTIMA CANOPY Data sheet Acoustic performance meets High Design ULTIMA CANOPY Installation Instructions I. GENERAL 1. Product

More information

Cable Trays Technical Instructions & Specifications

Cable Trays Technical Instructions & Specifications Cable Trays Technical Instructions & Specifications Products Catalogue Objective and Structure The company s main objective is the supply of quality products, with respect to: practical design increased

More information

GUARDRAIL POST STEEL

GUARDRAIL POST STEEL GUARDRAIL POST STEEL Guardrail posts meeting materials certification are evaluated and checked for: 1. Dimensional acceptance 2. Physical test results a. Chemical b. Physical 3. Galvanized or painted coating

More information

How to secure your property after a disaster

How to secure your property after a disaster How to secure your property after a disaster The Red Guide to Recovery HOuse secured properly Board-Up of Windows, Doors and Roof Hole. Lot secured with Perimeter Fencing. Fires, floods, tornadoes, hurricanes,

More information

PART 1 GENERAL 1.1 SECTION INCLUDES

PART 1 GENERAL 1.1 SECTION INCLUDES J-1 Section 09110 Long Form Specification INTERIOR METAL STUD FRAMING This section includes lightweight, usually 0.036 inch (0.9 mm) thick or lighter, non-axial load bearing metal stud framing including

More information

Operating Instructions for Plastic Flow Meter. Model: KSK

Operating Instructions for Plastic Flow Meter. Model: KSK Operating Instructions for Plastic Flow Meter Model: KSK 1. Contents 1. Contents... 2 2. Note... 3 3. Instrument Inspection... 3 4. Regulation Use... 3 5. Operating Principle... 4 6. Mechanical Connection...

More information

SECTION 27 05 36 CABLE TRAYS FOR COMMUNICATIONS SYSTEMS

SECTION 27 05 36 CABLE TRAYS FOR COMMUNICATIONS SYSTEMS SECTION 27 05 36 CABLE TRAYS FOR COMMUNICATIONS SYSTEMS PART 1 GENERAL 1.01 DESCRIPTION A. The work covered by this section of the Specifications includes all labor necessary to perform and complete such

More information

sound reduction systems for commercial, educational and industrial environments

sound reduction systems for commercial, educational and industrial environments sound reduction systems for commercial, educational and industrial environments Tel: +44 ()14 3874 Fax: +44 ()14 38957 E-mail: info@soundreduction.co.uk Web: www.soundreduction.co.uk soundblocker Acoustic

More information

STRUCTURAL CONCEPT FOR LIGHT GAUGE STEEL FRAME SYSTEM

STRUCTURAL CONCEPT FOR LIGHT GAUGE STEEL FRAME SYSTEM Chapter 9 STRUCTURAL CONCEPT FOR LIGHT GAUGE STEEL FRAME SYSTEM 9.1 BACKGROUND Steel is widely used in the construction of multi-storey buildings. However, steel construction is seldom used and is traditionally

More information

Installation information. METTLER TOLEDO MultiRange DW150 / DW150T wall scale

Installation information. METTLER TOLEDO MultiRange DW150 / DW150T wall scale Installation information METTLER TOLEDO MultiRange DW150 / DW150T wall scale DW150 / DW150T wall scale Contents Contents Page 1. Installation... 2 1.1 Preparatory work... 2 1.2 Installing the wall plates

More information

usg.com/me USG Middle East, Ltd. Dammam, Saudi Arabia E-mail: info@usgme.com Fax: +966 3 8121029 +966 3 8120995

usg.com/me USG Middle East, Ltd. Dammam, Saudi Arabia E-mail: info@usgme.com Fax: +966 3 8121029 +966 3 8120995 USG Middle East, Ltd. Dammam, Saudi Arabia E-mail: info@usgme.com Fax: +966 3 8121029 +966 3 8120995 Riyadh, Saudi Arabia E-mail: riyadhsales@usgme.com Fax: +966 1 4772734 +966 1 4772734 Jeddah, Saudi

More information

MultiPost-AP anchorage device

MultiPost-AP anchorage device MultiPost-AP anchorage device MultiPost anchorage point Type 1 Fixing on reinforced concrete with large, 360 rotating stainless steel lifting eye for the simultaneous securing of max. 2 persons. This can

More information

Quality Regulations for Profiles

Quality Regulations for Profiles Quality Regulations for Profiles September 2010 Quality Regulations for Profiles Page 2/42 Contents Preface... 4 1. Terms and Definitions... 5 1.1 Third parties... 5 1.2 Independent laboratories... 5 1.3

More information

RESIDENTIAL PLUMBING ALTERATIONS PERMIT REQUIREMENTS

RESIDENTIAL PLUMBING ALTERATIONS PERMIT REQUIREMENTS RESIDENTIAL PLUMBING ALTERATIONS PERMIT REQUIREMENTS The following guidelines are intended to assist with the permit acquisition process with regard to Plumbing Alterations. Not all information, or additional

More information

CLEAR-DIVISIONS CENTERFOLD

CLEAR-DIVISIONS CENTERFOLD CLEAR-DIVISIONS CENTERFOLD Introduction: The following three (3) part specification offers the Standard and Optional features for the CLEAR-DIVISIONS CENTERFOLD moveable The yellow highlighted areas in

More information

Connection Solutions

Connection Solutions Connection Solutions DESIGN BUILD SYSTEM Connection Solutions for Cold formed Steel Construction Complies with; AS/NZS 4600:2005 AISI S100:2007 AS/NZ 1397 ASTM A653 DESIGN & BUILD SYSTEM FRAMECAD Construction

More information

Guidelines for Earthquake Bracing Residential Water Heaters

Guidelines for Earthquake Bracing Residential Water Heaters Guidelines for Earthquake Bracing Residential Water Heaters Department of General Services Division of the State Architect In accordance with the Health and Safety Code Section 19215, the Division of the

More information

PITCHED ROOF STRUCTURES

PITCHED ROOF STRUCTURES PITCHED ROOF STRUCTURES for framed and frameless photovoltaic modules Needed tools and materials: cordless screwdriver 10mm and 13mm spanners 5mm Allen key bolts, screws and tools for fixing the system

More information

39HQ Airovision Air Handling Units

39HQ Airovision Air Handling Units 39HQ Airovision Air Handling Units Mounting instructions CONTENTS 1 - TRANSPORT AND LIFTING INSTRUCTIONS... 3 1.1 - General... 3 1.2 - Transport and storage... 3 1.3 - Roof edge protection during transport

More information

SOHOline and SOHO Slimline The SOHOline and SOHO Slimline offer a modular, sturdy and compact design

SOHOline and SOHO Slimline The SOHOline and SOHO Slimline offer a modular, sturdy and compact design SOHOline and SOHO Slimline The SOHOline and SOHO Slimline offer a modular, sturdy and compact design Ideal installation for; Offices Branch Offices Schools Computer Aided Classes Government Offices Hotels

More information

Data Sheet VITOSOL 100. Flat collectors for the utilisation of solar energy. Vitosol 100. Part nos. and prices: see price list

Data Sheet VITOSOL 100. Flat collectors for the utilisation of solar energy. Vitosol 100. Part nos. and prices: see price list VITOSOL 100 Flat collectors for the utilisation of solar energy Data Sheet Part nos. and prices: see price list File in: Vitotec 1 Manual, Index 16 Vitosol 100 Type s 1.7 Vitosol 100 Type s 2.5 Vitosol

More information

FLOODED BATTERY RACKS SELECTION GUIDE FOR RDB & RDC SERIES, STANDBY POwER RACKS

FLOODED BATTERY RACKS SELECTION GUIDE FOR RDB & RDC SERIES, STANDBY POwER RACKS 12-560 FLOODED BATTERY RACKS SELECTION GUIDE FOR RDB & RDC SERIES, STANDBY POwER RACKS Non-seismic and Earthquake Protected (EP1, EP2), IEEE-693,,, D, DJ, DJU, J, K, and L/XT Cell Types Heavy Gauge Steel

More information

Colocation Rack Secure, Separate Server Hosting and Housing in Data Centers

Colocation Rack Secure, Separate Server Hosting and Housing in Data Centers Colocation Rack Secure, Separate Server Hosting and Housing in Data Centers Colocation Rack Secure, Separate Server Hosting and Housing in Data Centers An intelligent physical infrastructure is required

More information

CPA Steel Stud Framing Page 1 of 11

CPA Steel Stud Framing Page 1 of 11 CPA Steel Stud Framing Page 1 of 11 STEEL STUD FRAMING General Requirements City of Palo Alto (CPA) Building Inspection Division 285 Hamilton Ave. Inspection Request: 650 329-2496 Building Division IVR#

More information

SECTION 08332 COILING COUNTER DOORS. Display hidden notes to specifier. (Don't know how? Click Here)

SECTION 08332 COILING COUNTER DOORS. Display hidden notes to specifier. (Don't know how? Click Here) SECTION 08332 COILING COUNTER DOORS Display hidden notes to specifier. (Don't know how? Click Here) PART 1 GENERAL 1.1 SECTION INCLUDES A. Coiling Metal Counter Doors. B. Coiling Counter Fire Doors. 1.2

More information

CHAPTER 6 CONSTRUCTION TYPES

CHAPTER 6 CONSTRUCTION TYPES CHAPTER 6 CONSTRUCTION TYPES SECTION 601 GENERAL 601.1 Scope. Provisions of this chapter shall govern the classification of construction type by materials and fire resistance of its elements and the use

More information

SECTION 08360 SECTIONAL OVERHEAD DOORS 521 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS

SECTION 08360 SECTIONAL OVERHEAD DOORS 521 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS SECTION 08360 SECTIONAL OVERHEAD DOORS 521 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS Display hidden notes to specifier by using Tools / Options / View / Hidden Text. On newer versions of Microsoft Word

More information

USG Australasia. USG Drywall Grid. Suspension System

USG Australasia. USG Drywall Grid. Suspension System USG Australasia USG Drywall Grid Suspension System Apartments Hotels Retail Malls Banks Lobbies Schools Medical Industrial Food Preparation Areas The USG Drywall Grid Suspension System is expressly designed

More information

MERO Access Floor / Floor systems for data centers * *Ready for Cloud-Computing

MERO Access Floor / Floor systems for data centers * *Ready for Cloud-Computing MERO Access Floor / Floor systems for data centers * *Ready for Cloud-Computing Innovative Komplettlösungen aus einer Hand Innovative solutions from one source Development Access floor Consulting Hollow

More information

FERMACELL Powerpanel H 2 O for Wet & Moisture affected areas

FERMACELL Powerpanel H 2 O for Wet & Moisture affected areas FERMACELL Powerpanel H 2 O for Wet & Moisture affected areas Powerpanel H 2 O is a cement based board from FERMACELL. Board Characteristics Board Thickness 12.5 mm Board Sizes 1000 x 1200 mm 50 sheets/pallet

More information

TECHNICAL RECOMMENDATION

TECHNICAL RECOMMENDATION TECHNICAL RECOMMENDATION NO: 9 DESIGN OF LIGHT TIMBER FRAMED WALLS AND FLOORS FOR FIRE RESISTANCE Peter Collier Contents Design of Light Timber Framed Walls and Floors for Fire Resistance Relevance Acceptance

More information

DIVISION: 07 00 00 THERMAL AND MOISTURE PROTECTION SECTION: 07 41 13 METAL ROOF PANELS REPORT HOLDER: FIRESTONE BUILDING PRODUCTS COMPANY, LLC

DIVISION: 07 00 00 THERMAL AND MOISTURE PROTECTION SECTION: 07 41 13 METAL ROOF PANELS REPORT HOLDER: FIRESTONE BUILDING PRODUCTS COMPANY, LLC 0 ICC ES Report ICC ES (800) 423 687 (62) 699 043 www.icc es.org 000 Most Widely Accepted and Trusted ESR 3422 Reissued 09/201 This report is subject to renewal 09/2016. DIVISION: 07 00 00 THERMAL AND

More information

Knürr DCM. Knürr DCM. 19 Server Rack System 19 Heavy Duty Rack 1.2 to 1.9 1.1

Knürr DCM. Knürr DCM. 19 Server Rack System 19 Heavy Duty Rack 1.2 to 1.9 1.1 Knürr DCM 19 Server Rack System 19 Heavy Duty Rack 1.2 to 1.9 1.1 Knürr DCM conquers the world Standardization in the data center begins with the Knürr DCM! The Knürr DCM is the modular building block

More information

[see Figure 3 below] Ferrite tile walls and ceiling RF Absorber parcel walls and ceiling Removable floor section to make fully anechoic

[see Figure 3 below] Ferrite tile walls and ceiling RF Absorber parcel walls and ceiling Removable floor section to make fully anechoic Test Room ID: R21F Description: SEMI ANECHOIC SHIELDED TEST ENCLOSURE Primary Testing Uses: FCC, CE Mark Dimensions: 9.75m x 6.10m x 5.49m (32ft. x 20ft. x 18ft.) [see Figure 3 below] Construction: Galvanized

More information

Isover HVAC Application Handbook Installing fire protection insulation to metal ductwork

Isover HVAC Application Handbook Installing fire protection insulation to metal ductwork Isover HVAC Application Handbook Installing fire protection insulation to metal ductwork HVAC - Fire protection of metal ductwork Fire protection Thermal insulation Isover ULTIMATE TM Protect - Fire protection

More information

Dubai Municipality Standard DMS 1: Part 5: 2004

Dubai Municipality Standard DMS 1: Part 5: 2004 Specification for precast concrete blocks Part 5: Normal-weight concrete-polystyrene sandwich masonry blocks Issue Date Revision Revision Description Prepared by Approved by Authorized by 19/12/2004 Issue

More information

1997 Uniform Administrative Code Amendment for Earthen Material and Straw Bale Structures Tucson/Pima County, Arizona

1997 Uniform Administrative Code Amendment for Earthen Material and Straw Bale Structures Tucson/Pima County, Arizona for Earthen Material and Straw Bale Structures SECTION 70 - GENERAL "APPENDIX CHAPTER 7 - EARTHEN MATERIAL STRUCTURES 70. Purpose. The purpose of this chapter is to establish minimum standards of safety

More information

UL 580 TEST REPORT. Rendered to: ARMSTRONG WORLD INDUSTRIES. SERIES/MODEL: MW Vector PRODUCT TYPE: Ceiling System, 3' OC

UL 580 TEST REPORT. Rendered to: ARMSTRONG WORLD INDUSTRIES. SERIES/MODEL: MW Vector PRODUCT TYPE: Ceiling System, 3' OC UL 580 TEST REPORT Rendered to: ARMSTRONG WORLD INDUSTRIES SERIES/MODEL: MW Vector PRODUCT TYPE: Ceiling System, 3' OC Report No.: Test Dates: 12/14/09 Through: 12/22/09 Report Date: 03/12/10 Expiration

More information

SECTION 05 42 16 COLD-FORMED METAL DECK FRAMING Elevations Steel Deck Framing by Trex

SECTION 05 42 16 COLD-FORMED METAL DECK FRAMING Elevations Steel Deck Framing by Trex (Specifier Note: The purpose of this guide specification is to assist the specifier in correctly specifying cold-formed metal deck framing products and execution. The specifier needs to edit the guide

More information

Composite Panel Firewall Systems

Composite Panel Firewall Systems Composite Panel Firewall Systems part of the Protecting more than your business Insulated mineral fibre panels have excellent thermal and acoustic properties, ideal for factory and office partition walls.

More information

Guidelines for Earthquake Bracing of Residential Water Heaters

Guidelines for Earthquake Bracing of Residential Water Heaters Guidelines for Earthquake Bracing of Residential Water Heaters Department of General Services Division of the State Architect 1102 Q Street, Suite 5100 Sacramento, CA 95814 Phone: (916) 324-7099 Fax: (916)

More information

Now available with full IP65 rating: Protection from dust and water jets NEW: K470 Plus covered containers

Now available with full IP65 rating: Protection from dust and water jets NEW: K470 Plus covered containers Now available with full IP65 rating: Protection from dust and water jets NEW: K470 Plus covered containers Universal container K 470 the original since 1950 Often copied but never equalled or bettered

More information

HURRICANE MITIGATION RETROFITS FOR EXISTING SITE-BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES

HURRICANE MITIGATION RETROFITS FOR EXISTING SITE-BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES HURRICANE MITIGATION RETROFITS FOR EXISTING SITE-BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES 101 Retrofits Required. Pursuant to Section 553.844 553.884, Florida Statutes, strengthening of existing site-built,

More information

BOQ SPECIFICATIONS. The Blind system consist of a coated aluminium tube of 38 mm diameter with provision of fabric clamping.

BOQ SPECIFICATIONS. The Blind system consist of a coated aluminium tube of 38 mm diameter with provision of fabric clamping. BOQ SPECIFICATIONS VERTICAL BLINDS Vertical Blinds made of glass fibre fabrics in width 5 (or 4 ). Minimum overlapping of ¾ in fabric. Top aluminium anodized rail of 1.4 mm thickness. 2 inch wide channel

More information

TIGER Drylac U.S.A., Inc. 3855 Swenson Avenue St Charles, IL T 800 243 8148 F 877 926 8148 office.us@tiger-coatings.us www.tiger-coatings.

TIGER Drylac U.S.A., Inc. 3855 Swenson Avenue St Charles, IL T 800 243 8148 F 877 926 8148 office.us@tiger-coatings.us www.tiger-coatings. Product Data Sheet SERIES 69 - DRYZINC ZINC-RICH PRIMER (69/90500) Epoxy zinc-rich powder coating primer. Part of a two-coat TIGER Shield system. Designed to impart superior corrosion protection to steel

More information

Seismic Technical Guide

Seismic Technical Guide Technical Document Seismic Technical Guide Hanger Wire Attachment Code Requirements 1 The International Building Code (IBC) defines the requirement for hanger wire and their supports and attachment methods.

More information

HORIZONTAL INSTALLATION

HORIZONTAL INSTALLATION THERMO/SOLAR Žiar s.r.o. MANUAL FOR INSTALLATION PV SUPPORTING FRAMES HORIZONTAL INSTALLATION Technical alternation reserved A1410 1 12/2014 CONTENT ORD.NO. PAGE Mounting information 3 Mounting, flat roof

More information

TS83. Easy action door closer

TS83. Easy action door closer Easy action door closer THE MULTI-FUNCTION, MULTI-PURPOSE DOOR CLOSER Outstanding versatility. Quality assured. Tested to EN 1154. Decades of experience have gone into the development of the DORMA TS 83.

More information

CLEAR-DIVISIONS VARIOFOLD

CLEAR-DIVISIONS VARIOFOLD CLEAR-DIVISIONS VARIOFOLD Introduction: The following three (3) part specification offers the Standard and Optional features for the CLEAR-DIVISIONS VARIOFOLD moveable The yellow highlighted areas in the

More information

European Technical Approval ETA-12/0500

European Technical Approval ETA-12/0500 ETA-Danmark A/S Kollegievej 6 DK-2920 Charlottenlund Tel. +45 72 24 59 00 Fax +45 72 24 59 04 Internet www.etadanmark.dk Authorised and notified according to Article 10 of the Council Directive 89/106/EEC

More information

Requirements for Fire Protection of Light Weight Floor Systems **Act 1 Revisited**

Requirements for Fire Protection of Light Weight Floor Systems **Act 1 Revisited** PHRC Webinar Series Tuesday, September 9, 2014 1:00 pm Requirements for Fire Protection of Light Weight Floor Systems **Act 1 Revisited** Presented by: Bryan Heitzmann Credit(s) earned on completion of

More information

VERTICAL / FIXED BEAM CLAMP I-BEAM ANCHOR ADJUSTABLE FROM 4-14 Model # HD26249

VERTICAL / FIXED BEAM CLAMP I-BEAM ANCHOR ADJUSTABLE FROM 4-14 Model # HD26249 VERTICAL / FIXED BEAM CLAMP I-BEAM ANCHOR ADJUSTABLE FROM 4-14 Model # HD26249 IMPORTANT!!! ALL PERSONS USING THIS EQUIPMENT MUST READ AND UNDERSTAND ALL INSTRUCTIONS. FAILURE TO DO SO MAY RESULT IN SERIOUS

More information

RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000

RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000 RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000 SECTION R905 REQUIREMENTS FOR ROOF COVERINGS R905.1 Roof covering application. Roof coverings

More information

Specifications, Product Testing and Terminology

Specifications, Product Testing and Terminology Specifications, Product Testing and Terminology The following synopsis provides a review of various material and final product testing, which is performed on our products, as well as, many of our competitors.

More information

Policy on Water Heater Installations Policy No. UPC 510-1-94 Effective: September 1, 1995 Revised: February 10, 1996

Policy on Water Heater Installations Policy No. UPC 510-1-94 Effective: September 1, 1995 Revised: February 10, 1996 CITY OF SAN JOSE BUILDING DIVISION POLICY Policy on Water Heater Installations Policy No. UPC 510-1-94 Effective: September 1, 1995 Revised: February 10, 1996 All new and replacement water heaters installed

More information

Fire Barrier Duct Wrap 15A

Fire Barrier Duct Wrap 15A 3 Fire Barrier Duct Wrap 15A Commerical Kitchen Grease Duct Fire Protection System Product Data and Installation Instructions Compliance 1998 Edition Complies with International Mechanical Code Complies

More information

European technical approval

European technical approval Authorised and notified according to Article 10 of the Council Directive 89/ 106/EEC of 21 December 1988 on the approximation of laws, regulations and administrative provisions of Member States relating

More information

C09. S02. P02 P14 CasoLine mf. Including C09. S01. P02 P08 Sound absorbing solutions introduction

C09. S02. P02 P14 CasoLine mf. Including C09. S01. P02 P08 Sound absorbing solutions introduction C09. S0. P0 P Including C09. S0. P0 P08 Sound absorbing solutions introduction C09 Sound absorbing solutions Introduction Sound absorbing solutions This section details sound absorbing solutions which

More information

NATIONAL INSTITUTE OF BIOLOGICALS

NATIONAL INSTITUTE OF BIOLOGICALS Short Term Notice Inviting Quotations Quotations No. S.1-36/07/NIB/Engg. (Civil) Invitation to short term quotations for Repairing of damaged gypsum board false ceiling and painting with epoxy paint in

More information

Super Slider ADJUSTABLE FROM 3.5-12 Model #HD26229

Super Slider ADJUSTABLE FROM 3.5-12 Model #HD26229 Super Slider ADJUSTABLE FROM 3.5-12 Model #HD26229 IMPORTANT!!! ALL PERSONS USING THIS EQUIPMENT MUST READ AND UNDERSTAND ALL INSTRUCTIONS. FAILURE TO DO SO MAY RESULT IN SERIOUS INJURY OR DEATH. USERS

More information

Festoon 715 P PUR cable for flexible application in festoon systems

Festoon 715 P PUR cable for flexible application in festoon systems CABLES FOR CRANE AND CONVEYOR APPLICATIONS Festoon 715 P PUR cable for flexible application in festoon systems S AB BRÖCKSKES D-VIERSEN Festoon 715 P 1 x 16.0 mm 2 C Marking for Festoon 715 P 07150162:

More information

Pressure regulating valve with modulating kit, type DRV

Pressure regulating valve with modulating kit, type DRV Operation Installation and Maintenance Instructions Pressure regulating valve with modulating kit, type DRV hp-technik GmbH Industriepumpen-Förderaggregate und Anlagenbau Gablonzer Straße 21 D-76185 Karlsruhe

More information

Spetec Laminar Flow Systems. Operating Instructions

Spetec Laminar Flow Systems. Operating Instructions Spetec Laminar Flow Systems Operating Instructions 1 Spetec Laminar Flow Systems Operating Instructions Thank you for your trust in the Spetec clean room systems! Your chosen system is ideally suited for

More information

CLEAR-DIVISIONS APERTO

CLEAR-DIVISIONS APERTO CLEAR-DIVISIONS Introduction: The following three (3) part specification offers the Standard and Optional features for the CLEAR-DIVISIONS moveable glass wall system. The yellow highlighted areas in the

More information

Prestige 3D Dado & Skirting Technical

Prestige 3D Dado & Skirting Technical Prestige 3D Dado & Skirting Technical 693 technical hotline +44 (0)268 5637 Standards and approvals The Prestige 3D System is manufactured in accordance with the requirements of S EN 50085-: 05 and S 4662:

More information

Detailing of Reinforcment in Concrete Structures

Detailing of Reinforcment in Concrete Structures Chapter 8 Detailing of Reinforcment in Concrete Structures 8.1 Scope Provisions of Sec. 8.1 and 8.2 of Chapter 8 shall apply for detailing of reinforcement in reinforced concrete members, in general. For

More information

BOOTH DESIGN RULES NEW! mgerald@eventsdc.com

BOOTH DESIGN RULES NEW! mgerald@eventsdc.com BOOTH DESIGN RULES All exhibits must conform to the dimensions outlined below in order to assure ease of movement of participants and clear lines of visibility in the exhibit hall. For more information

More information

Evidence of Performance Resistance to wind load Watertightness Air permeability

Evidence of Performance Resistance to wind load Watertightness Air permeability Evidence of Performance Resistance to wind load Watertightness Air permeability Test Report 102 43093/1e Client Product YILDIZPEN PLASTIK SAN. VE TIC. LTD. STI. A.O.S.B 10039 Street No:18 Çigli Izmir Turkey

More information

Modular Access Floor for Data Center. From Rack to Row to Room to Building

Modular Access Floor for Data Center. From Rack to Row to Room to Building Modular Access Floor for Data Center From Rack to Row to Room to Building Why using Scneider Electric modular access floor in Data Centers The evolution of modern Data Centers emphasizes specific exigencies

More information

12.1 Schlüter -KERDI-BOARD

12.1 Schlüter -KERDI-BOARD I n n o v a t i v e p r o f i l e s 12.1 Schlüter -KERDI-BOARD S u b s t r a t e U N I V E R S A L S T R U C T U R A L P A N E L, B O N D E D W A T E R P R O O F I N G Application and Function Schlüter

More information

Linkeo 19" freestanding cabinets

Linkeo 19 freestanding cabinets 87045 LIMOGES Cedex France Telephone: (+33) 05 55 06 87 87 - Fax: (+33) 05 55 06 88 88 Linkeo 19" freestanding cabinets Page 1. General characteristics....1 2. Range....2 3. Technical characteristics...3

More information

UNIVERSAL RAILING, STEEL

UNIVERSAL RAILING, STEEL RAILINGS Page Universal Railing, steel 108-109 Large Module Railing, steel 110-111 Allround Railing, aluminium 112-113 Module Railing, aluminium 114-115 Standard Type Railing, aluminium 116-117 107 UNIVERSAL

More information

Architect/Contractor Information Package

Architect/Contractor Information Package Architect/Contractor Information Package 3M SelfCheck System C-Series C1 Model 877 This package provides architects and contractors with the information necessary for the successful installation of the

More information

WELAND TERMINOLOGY LOAD BEARING BAR CROSS BAR GRATING TYPE SAF MESH OPENING GRATING. LENGTH, SPAN WIDTH or LENGTH OF LOAD BAR GRATING

WELAND TERMINOLOGY LOAD BEARING BAR CROSS BAR GRATING TYPE SAF MESH OPENING GRATING. LENGTH, SPAN WIDTH or LENGTH OF LOAD BAR GRATING GRATING Page Terminology 6-7 Pedestrian Walkway Multipanels from Stock 8-13 Duckboard 13 Vehicular Multipanels with Load Tables 14-15 Kerb Angle Frames 16-17 Entrance Mats 18-20 Special Grating 22 Mesh

More information

Rutenbeck Network Connection Box Cat. 5, shielded. Cable installation. UAE Connection Box Cat. 5 Operating Instructions.

Rutenbeck Network Connection Box Cat. 5, shielded. Cable installation. UAE Connection Box Cat. 5 Operating Instructions. Rutenbeck Network Connection Box Cat. 5, shielded 1-gang, 1 x 8-pole Order No.: 0180 00 2-gang, 2 x 8-pole Order No.: 0178 00 1-gang, (especially for channel construction) Order No.: 0802 00 2-gang, (especially

More information

Solar Mounting System

Solar Mounting System Xiamen Antai New Energy Tech.Co., Ltd Installation Manual Antai Rail Solar Mounting System (Flat Roof Solution) Version 1.1 Office Add: 508#, North Tower, Guangxia Building Huli Torch Hi-tech Zone, Xiamen,

More information

WOODWORKS Linear. Assembly and Installation Instructions 1. GENERAL

WOODWORKS Linear. Assembly and Installation Instructions 1. GENERAL WOODWORKS Linear Assembly and Installation Instructions 1. GENERAL 1.1 Product Description WoodWorks Linear ceilings consist of unperforated nominal 4-1/2" wide x 8' long or 6" wide by 8' long wood plank

More information

INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks

INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks Securitron Magnalock Corp. www.securitron.com ASSA ABLOY, the global leader Tel 800.624.5625 techsupport@securitron.com in door opening solutions INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate

More information

Discipline: Structural Issued 04-26-06

Discipline: Structural Issued 04-26-06 California Department of General Services. Division of the State Architect. Product Acceptance Report STRUCTURAL SHEAR PANEL SURE-BOARD SERIES 200 PANELS PA-132 Discipline: Structural Issued 04-26-06 This

More information

Precision Miniature Load Cell. Models 8431, 8432 with Overload Protection

Precision Miniature Load Cell. Models 8431, 8432 with Overload Protection w Technical Product Information Precision Miniature Load Cell with Overload Protection 1. Introduction The load cells in the model 8431 and 8432 series are primarily designed for the measurement of force

More information

STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM

STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM Installed in Pre-engineered Steel Buildings Provides Lowest Cost Construction Method for CORROSIVE AND WET Environments PREFERRED SOLUTIONS, INC.

More information

HERZ-Thermal Actuators

HERZ-Thermal Actuators HERZ-Thermal Actuators Data Sheet 7708-7990, Issue 1011 Dimensions in mm 1 7710 00 1 7710 01 1 7711 18 1 7710 80 1 7710 81 1 7711 80 1 7711 81 1 7990 00 1 7980 00 1 7708 11 1 7708 10 1 7708 23 1 7709 01

More information

Evidence of Performance. Class 2. Class 5A. Class C4 / B4. Test Report No. 15-003655-PR01. ift Rosenheim 16.12.2015

Evidence of Performance. Class 2. Class 5A. Class C4 / B4. Test Report No. 15-003655-PR01. ift Rosenheim 16.12.2015 Evidence of Performance Test Report No. 15-003655-PR01 (PB-A01-02-en-01) Client Product Designation Performance-relevant product details Overall dimensions (W x H) Special features Alüminyum San. Tic.

More information

Narrow stile lock 1314

Narrow stile lock 1314 3 2 4 6 6 1 3 2 4 4 5 3 2 4 3 5.... ( (. ). ) 11 12 5 3 5 4 8 1 6 20 8.5 6.5 19 Backset 15 3 5 2 1 5 2 5 5 0 8 9 2 8 1 1 21-1mm 12 8 24 1 6 8 1 ( 9 2 5 ) ) ). ) Narrow stile lock 1314 CE EN 12209 2 4 5

More information