1 Isover HVAC Application Handbook Installing fire protection insulation to metal ductwork

2 HVAC - Fire protection of metal ductwork Fire protection Thermal insulation Isover ULTIMATE TM Protect - Fire protection for metal ductwork It is vital to develop safe, durable and reliable fire protection solutions for ventilation systems as a fire can easily spread from the point of origin via ductwork. Produced with Isover glass wool technology Isover Ultimate Protect is an innovative new generation mineral wool that combines all the advantages of conventional thermal and acoustic insulation with top level fire protection. Providing excellent fire resistance and top-rated reaction to fire, Isover Ultimate Protect fulfils the requirements of BS 476: Part 24 for ventilation and smoke extract ducts. The Isover Ultimate Protect product range, also known as U Protect, consists of Slab and Wired Mat solutions. Offering up to two hours fire protection for both vertical and horizontal applications of rectangular and circular ductwork systems. + + = Effective fire protection A top performer when it comes to material stability and thermal resistance at high temperatures, Isover Ultimate Protect offers a Euroclass A1 fire rating and has been certified to comply with BS 476: Part 24. Ease of installation Excellent manageability ensures that cutting, bending and fitting is faster and more efficient. The Isover Ultimate Protect Wired Mat range is specifically designed for easy installation on circular ductwork. Lightweight 65% lighter than conventional stone wool products, Isover Ultimate Protect makes light work of installation and its low pack weight meets the most stringent of workplace Health and Safety standards. up to 65% lighter than traditional stone wool 2

3 Effective fire protection Euroclass harmonisation Commonly accepted in England, Scotland and Wales, Euroclass is a harmonised European classification system (A1, A2, B, C, D, E and F) for products, measuring their reaction to fire. A1 corresponds to the safest situation, E the most dangerous and F would not be classified. Isover Ultimate Protect achieves Euroclass A1 rating, the fire classification for product of non-combustibility. Reaction to fire Under reaction to fire, one of the most important issues is the potential for flashover. This is the spontaneous ignition of hot smoke, gases and fuel which can lead to a fire spreading uncontrollably. Isover Ultimate Protect does not promote flashover. Other hazards found in fires and for risk assessment, are classified by s and d. These relate to the quantity of smoke production (s1 being the lowest production of smoke up to s3, which means high production of smoke) and the possible fall of flaming droplets d (d0 none, up to d3). Isover Ultimate Protect has an index of s1, d0 fire rating classification. Class 0 compliance Class 0 compliance refers to the surface properties of a product, specifically Surface Spread of Flame or non-combustability of the surface. BS 476: Parts 6 and 7 also needs to be satisfied. Isover Ultimate Protect range has a Class 0 foil and passes both these tests. Isover Ultimate Protect exceeds all these standards proving its excellent fire credentials Technical enquiries: techinsulation@saint-gobain.com or

4 HVAC - Fire protection of metal ductwork protection Fire insulation Thermal Why use Isover ULTIMATE TM Protect? Easy and fast installation Ultra-light and adaptable, the Isover Ultimate Protect range makes cutting, bending or filling, faster and more efficient than ever. Lightweight Up to 65% lighter than conventional thermal, acoustic and fire insulation products, Isover Ultimate Protect s low pack weight and grip-friendly touch also meet the most stringent standards for Health and Safety in the workplace. Features Meets BS 476: Part 24 for ventilation ductwork Euroclass A1 fire rating; Class 0 compliance High levels of thermal performance Superior acoustic performance Up to 65% lighter than traditional stone wool systems Easy to cut, bend and fit Off-cuts can be used Only need glue at wall penetrations No need for pre-fabrication High quality mineral wool Benefits Increased fire protection performance Totally non-combustible, top level reaction to fire performance Meets all UK thermal Building Regulations and offers energy savings 50% better sound absorption than typical competitor products Easier to handle 50% faster installation Standard insulators knife can be used Minimises waste on site Less glue required, faster installation Cost savings Will not absorb moisture from the surrounding air and is chemically inert - will not accelerate corrosion of steel, copper or aluminium Performance will not deteriorate over time - long product life, no ageing of product Compression resistance - product will not sag or consolidate over time in normal applications up to 50% quicker installation time than traditional solutions 4

5 Installation detail Before you start A. Choose the insulation thicknesses Choose the appropriate thickness from the table below by selecting the desired duct type, fire rating, duct orientation and fire location. Isover Ultimate Protect thickness table Rectangular duct Circular duct Fire location Fire class 1 hour 2 hours Duct orientation Fire inside duct Inside 60mm 80mm* Horizontal 80mm 100mm Vertical Fire outside duct Outside 60mm 80mm* Horizontal 60mm 80mm* Vertical In case both fire locations need to be covered Both 60mm 80mm* Horizontal 80mm 100mm Vertical Use of 1 product for both duct orientations Outside 60mm 80mm* Inside 80mm 100mm Both Use of 1 product for all cases Both 80mm 100mm Both Fire location Fire class 1 hour 2 hours Duct orientation Fire inside duct Inside 75mm 120mm Horizontal 75mm 120mm Vertical Fire outside duct Outside 75mm 120mm Horizontal 75mm 120mm Vertical In case both fire locations need to be covered Both 75mm 120mm Horizontal 75mm 120mm Vertical Use of 1 product for both duct orientations Outside 75mm 100mm Inside 75mm 120mm Both Use of 1 product for all cases Both 75mm 120mm Both For rectangular ducts use U Protect 4.0 Alu 1 Slab and for circular ducts use U Protect 4.0 Alu Wired Mat. *Smoke extraction requires 2 hours fire protection. Note that for rectangular ducts these insulation thicknesses should be increased from 80mm as shown in the table to 90mm. Technical enquiries: techinsulation@saint-gobain.com or

6 HVAC - Fire protection of metal ductwork Fire protection Thermal insulation Kitchen extract Type B kitchen extract solution Rectangular duct Fire location Inside Fire Class 1 hour 2 hours Duct orientation Kitchen Extract 60mm 80mm Horizontal 80mm 100mm Vertical Circular duct Fire location Inside Fire Class 1 hour 2 hours Duct orientation Kitchen Extract 75mm 120mm Horizontal 75mm 120mm Vertical For rectangular ducts use U Protect 4.0 Alu 1 Slab and for circular ducts use U Protect 4.0 Alu Wired Mat. Many specifiers and approval authorities consider that a fire inside a kitchen is the most difficult scenario for a kitchen extract system. This is simulated in test standards, BS476: Part 24: 1987, with a fire inside the duct (Type B) where: a) the inside of kitchen ductwork is required to be cleaned regularly (as per the HVAC s publication TR/19) and therefore the amount of grease should be minimal; and b) the extract system is likely to vent a fire away from the duct, and from the kitchen. This would mean that the kitchen extract fire protection solution would be the same as that prescribed for Type B ventilation duct systems, ensuring that they meet the required integrity, insulation and stability criteria of the previously mentioned standards. Should the approval authority be concerned that a fire in a compartment next to a kitchen could ignite grease that has built up within the duct, and thus cause a fire in the kitchen, then the guidance in BS476: Part24: 1987 for kitchen extract ducts with combustible linings should be used. Please contact our Technical department on or techinsulation@saint-gobain.com Insulation product range Product Order Thickness Width Length Slabs per m 2 per Packs per m 2 per Code (mm) (mm) (mm) pack pack pallet pallet Ultimate Protect Slab 4.0 Alu 1 Ultimate Protect Wired Mat 4.0 Alu

7 Choose the insulation thickness: Summary Isover Ultimate TM Protect applications: Supply and extract ventilation systems Smoke extract Kitchen extract Isover Ultimate Protect performance summary: Thickness requirements of slabs for rectangular ductwork 1 hour protection 1 hour fire protection horizontal ventilation and smoke extract ductwork: 60mm Isover Ultimate Protect Slab 1 hour fire protection vertical ventilation and smoke extract ductwork: 80mm Isover Ultimate Protect Slab 1 hour fire protection horizontal Type B kitchen extract: 60mm Isover Ultimate Protect Slab 2 hours protection 2 hours fire protection horizontal ventilation ductwork: 80mm Isover Ultimate Protect Slab 2 hours fire protection vertical smoke extract ductwork: 100mm Isover Ultimate Protect Slab 2 hours fire protection vertical ventilation and smoke extract ductwork: 100mm Isover Ultimate Protect Slab 2 hours fire protection vertical Type B kitchen extract: 100mm Isover Ultimate Protect Slab Thickness requirements of Wired Mats for circular ductwork 1 hour fire protection for all applications: 75mm Isover Ultimate Protect Wired Mat 2 hours fire protection for all applications: 120mm Isover Ultimate Protect Wired Mat Technical enquiries: techinsulation@saint-gobain.com or

8 HVAC - Fire protection of metal ductwork Fire protection Thermal insulation B. Choose pins and pin fixing positions Steel pin information The insulation is fixed to the duct using steel pins, 2.7mm to 3mm nominal diameter, and spring steel washers, minimum 38mm diameter. The pins are stud-welded or self-drilling steel pins. Pin options Stud welded or self-drilling pins Self-drilling pins e.g. LENNE IBS1 self-drilling screw pins OR Pins that include a steel base plate which fasten to the duct (minimum of two M4 steel self-drilling/ self-tapping screws or two M4 steel rivets, e.g. Big head M5/B23 studs) NOTE: The length of pin should be equal to the insulation thickness + 3mm Pin fixing positions Horizontal and vertical rectangular ducts See pin pattern pages 9 and 10 Horizontal circular ducts No pins required Vertical circular ducts Vertical installation requires that the insulation mats are to be secured with pins and washers Place 2.7mm diameter pins and 30mm washers around the duct with c 250mm, at 100mm distance from all mat joints. For further information on the Isover Ultimate Protect range, please contact us on techinsulation@saint-gobain.com or for technical advice please call

9 There are two simple rules that apply: The distance of the self drilling pins OR stud welded pins from the edge of the duct OR the slab joints should not exceed 80mm. The maximum distance between pin OR Isover FireProtect Screws should not exceed 260mm. These apply to all rectangular duct orientations. See page 10 for cross-section of duct and slab overlaps. Rectangular horizontal ducts Underside slabs (note the side slabs are omitted) Example of pin positions and Isover FireProtect Screw positions l = 1200mm 1200mm l = 1200mm l 420mm 420mm Side slabs (note the top slab is omitted) l 420mm Example shows overlapping of the side slabs onto the underside slabs l = 1200mm l = 1200mm l 420 l = 1200mm l 420mm l 420mm l 420mm Key = Pins = Isover FireProtect Screw l 420 l 420mm NOTE: No glue or pins are used to fix the top slab. These are only fixed with the use of Isover FireProtect Screws, (shown above as the top row). l 420 Technical enquiries: techinsulation@saint-gobain.com or

10 HVAC - Fire protection of metal ductwork Fire protection Thermal insulation Rectangular vertical ducts Example of pin positions and Isover FireProtect Screw positions Overlapping on main duct face Side slabs showing pin positions 1200mm l = l = l = l 420 l 420 l 420mm & Wool & Wool 420mm thickness 90mm l or 420 or & Wool l 400mm thickness & Wool & Wool 90 thickness = 100mm or or l 400 & Wool 400 Wool For rectangular thickness vertical = 100 ducts, apply the largest board to the longest side leaving an overlap equivalent thickness to the thickness 100 of the U Protect slab, on either side of the duct. Repeat for the other side, then place the smaller boards between the overlaps created from the first two steps. 10

11 C. Calculate the amount of glue and paint needed Typical coverage rates for a penetration: Isover Protect BSF Intumescent Paint and Isover Protect BSK Adhesive both supplied in 15kg tubs. Volume 7.9 litres OR supplied in 310ml tubes. Weight 0.59kg. Coverage rates are given below per linear metre of joint in Isover Ultimate Protect Slab and Wired Mat, based on a thickness of 2mm. On-site usage of paint / glue will vary - these coverage rates should therefore be used for guidance purposes only. How much paint and glue is required: 1) Calculate the total linear metreage of the penetration using the following sum: (4 x width of duct) + (4 x height of duct - (2 x insulation thickness in metres)). 2) Select the insulation thickness requirement from the table below, read across the table to identify the approximate weight (kg) of Isover Protect BSF Intumescent Paint and Isover Protect BSK Adhesive required per linear metre. 3) To calculate the total paint / glue required for this job, use the following: Total linear metreage of the penetration (calculated in step 1) x approximate weight (kg) of Isover Protect BSF Intumescent paint / Isover Protect BSK Adhesive (identified in step 2). 4) Use this final figure to determine if the job requires a 15kg Tub or a 310ml (0.59kg) tube, by comparing the total weight calculated in Step 3 to the corresponding tub / tube weight. Thickness of Isover Protect BSF Intumescent Paint Isover Protect BSK Adhesive Ultimate Slab Approximate weight Approximate volume Approximate weight Approximate volume (kg) of Isover Protect (l) of Isover Protect (kg) of Isover Protect (l) of Isover Protect BSF Intumescent BSF Intumescent BSK Adhesive per BSK Adhesive per Paint per linear Paint per linear linear metre linear metre metre at penetration metre at penetration at penetration at penetration For further information on the Isover Ultimate Protect range, please contact us on techinsulation@saint-gobain.com or for technical advice please call Technical enquiries: techinsulation@saint-gobain.com or

12 HVAC - Fire protection of metal ductwork Fire protection Thermal insulation D. Complete wall / floor penetrations 5 steps to installation Installation through the construction is completed in 5 steps. The same general principle is used for both rectangular and circular ducts regardless of duct orientation. Step 1: Positioning Place the duct in the penetration of the construction, with a 50mm gap between the duct wall and opening. Fit a stiffener (steel tube) to the duct where the duct passes through the penetration. NOTE: Stiffeners are not used with circular ducts Step 2: Insulation Using the same insulation being used for the rest of the duct, fully pack the space between the duct and the partition. Ensure tight compression in order to completely fill the opening. Step 3: Sealing Using a spatula apply an approx 2mm thick layer of Isover Protect BSF to BOTH sides of the construction, to seal the joint. < Isover Protect BSF Intumescent Paint 310ml tube < Isover Protect BSF Intumescent Paint 15kg tub 12

13 Installation procedure Step 4a: Reinforcing a rectangular duct Fix an L-profile (30mm x 30mm x 3mm) around the duct on both sides of the construction with steel rivets. Using two steel screws for each side, ensure the top and bottom profiles are fixed to the construction. Step 4b: Reinforcing a circular duct Steps 1-3 are completed using U Protect Wired Mat. Screw a suspension bracket (30mm x 2mm) to the duct on both sides of the construction. Fix long L-profiles (30mm x 30mm x 3mm) above and below the bracket with one rivet each (4mm x 13mm). Fix short L-profiles (30mm x 30mm x 3mm) with nuts and bolts (M8) to the bracket eye. The use of L-profiles is part of the integrity requirements of BS 476: Part 24 and is a compulsory requirement with all manufacturers passive fire protection systems. Step 5: Duct insulation Glue the ends of the insulation to the construction using Isover Protect BSK Adhesive (thickness approx 2mm). Install the insulation so that it is adjacent and tightly fitted against the penetration. The insulation must be cut leaving excess length, so that it exerts some pressure between the penetration and the last fitted piece of insulation. This applies to both rectangular and circular ducts. Technical enquiries: techinsulation@saint-gobain.com or

14 HVAC - Fire protection of metal ductwork Fire protection Thermal insulation E. Complete the installation Horizontal and vertical rectangular ducts Secure the corner joints with Isover FireProtect Screws (Three screws per side at 300mm centres). The screw length must be twice the insulation thickness. Isover FireProtect Screws No glue or pins Top slab covering side slabs Welded pins Isover Ultimate Protect slab, Isover FireProtect Screw and pin position for horizontal ducts Installation principle for horizontal circular ducts 14 Isover Ultimate Protect slab, Isover FireProtect Screw and pin position for vertical ducts Isover Ultimate Protect insulation slabs need to be cut to fit the duct as tightly as possible. The insulation may need to be cut to fit around flanged duct joints (see left). Horizontal and vertical circular ducts Using clamping rings, secure the joints of the insulation mats together; or bind the edges of the wired mats together with stainless steel wired, minimum 1.5mm in diameter. For ducts greater than 1000mm diameter (up to 1250mm diameter), add a 120mm wide x 30mm thick collar of insulation over the duct joints to protect the flanges. Use standard threaded rods and suspension brackets as hangers for the duct. Place these hangers inside the insulation. The rods do not need to be protected by insulation, except the first 30mm of the drop rod (see pages 18-19). For vertical circular ducts, fix the insulation using self-drilling or self-tapping pins, spaced at 250mm nominal centres (see page 8). Note: There is no need to cut the insulation at the duct joint due to the flexibility of the insulation.

15 Installation procedure Access hatch design Any access hatch needs to be easy to remove and replace, therefore the design must maintain the strength of the duct section and not interrupt a cross joint or stiffener. The hatch can be a proprietary design provided that it is securely fastened to the duct. The Isover Ultimate Protect insulation slabs can overlap the opening (see below), or can have a stepped perimeter. The pigtail screw type of fixing can be used, provided that it is capable of being used repeatedly. Alternatively the fixings can penetrate through the fixed insulation to the steel duct. Access panels Isover FireProtect Screws Slab with the same thickness as the one needed for the classification Two or three-sided ducts Isover Protect BSK Adhesive is to be used between the insulation slab edges and the soffit. If the gap between the duct and soffit is less than 50mm, no additional fixtures are needed. < Isover Protect BSK Adhesive For larger distances (up to 100mm), a metal angle 50mm x 50mm x 1.2mm should be fitted internally and fixed to the slab with a proprietary metal fixing at max 300mm centres. Additional Stud Welded Pins or Self-Drilling Pins should be fixed to the metal angle at the required centres. < Isover Protect BSK Adhesive < Isover Protect BSK Adhesive < < Isover FireProtect Screws, fixed at required centres Stud Welded Pins or Self-Drilling Pins, fixed at required centres < < Stud Welded Pins or Self-Drilling Pins, fixed at required centres Isover FireProtect Screws, fixed at required centres Technical enquiries: techinsulation@saint-gobain.com or

16 HVAC - Fire protection of metal ductwork Fire protection Thermal insulation Preparation of rectangular ductwork prior to insulating Duct sheeting The steel duct is constructed in sections of hot dipped galvanised steel sheet, mild steel sheet or stainless steel sheet, minimum 0.7mm thick. Thickness of steel sheet 0.7mm 0.8mm 1.0mm Maximum size of duct (longer side) Up to 1250mm Up to 1500mm Up to 2000mm Maximum duct sizes: Rectangular ducts 2000mm x 1500mm Drop rods and hangers for rectangular horizontal ducts Each steel hanger consists of two threaded drop rods, minimum M10, and a channel section bearer, minimum 30mm x 30mm x 3mm thick. Fasten the bearer to the drop rods using hexagonal nuts and washers. Each hanger must be positioned so that it is adjacent to (within 250mm of) a cross joint or stiffening collar. The maximum spacing of the hangers is 1250mm. The spacing of the hangers and the size of the steel hanger components must be adjusted so that the tensile stress in the rods and the bending stress in the channels do not exceed 15N/mm 2 for fire resistance periods up to 60 minutes and 10N/mm 2 for fire resistance periods up to 120 minutes. The drop rods and bearers are positioned inside the insulation material, with the drop rods nominally 10mm from the steel duct. NOTE: The steel frame to be independently fire rated. Drop rod anchors When fixing to a concrete construction Use all-steel expanding anchors to fasten the threaded rod hangers to concrete soffits. The drop rod anchors should penetrate the concrete by at least 50mm, to achieve 120 minutes of fire resistance. When fixing to a steel supporting construction Drill a hole through the steel member, allowing the drop rod anchors to be supported by a steel nut and washer above. If a clamp type fixing is used, the clamp must be steel, suitable for the purpose. It should pass around the steel member and be fastened back on itself. 16

17 Preparation of ductwork Flanges As per HVAC Specification DW144, typically use J3 and above at maximum 1250mm centres. Using spot welds at 150mm nominal centres fasten the Lindab flanges or equivalent, (minimum size 30mm x 30mm x 1.2mm thick) at each cross joint. Fasten the flanges together with 40mm steel clamps at 265mm maximum centres. Use a ceramic tape gasket (20mm wide x 3mm thick) between the flanges to seal the joints. See Figure below: The Lindab flanges are fitted with steel corner plates (minimum 95mm x 95mm x 2.5mm thick). Slot these into the flanges at each corner and bolt them together with an M10 steel nut and bolt at each corner. Stiffeners Attach steel stiffeners at 90 angles to any side of the duct section where the width or depth exceeds 500mm. Position these at mid-width / depth and mid-length in each duct section. Each stiffener should consist of a steel tube (16mm diameter x 2mm thick) Fasten the stiffeners to the duct walls with a steel washer of the same size, on the outside of the duct wall. Use 72mm diameter x 1mm thick washers to fasten the stiffener, on the inside with M6 steel bolts. Rectangular duct showing stiffener NOTE: Clamps that rely on friction to hold them in place are not suitable. Technical enquiries: techinsulation@saint-gobain.com or

18 HVAC - Fire protection of metal ductwork Fire protection Thermal insulation Supports for rectangular vertical ducts The steel section can either span across the opening in the concrete floor or form part of a cantilever bracket that is fastened to the building structure. To prevent buckling of the duct, the distance between supports should not exceed eight times the smallest lateral dimension across the outside face of the steel duct. The weight of the duct system is taken by the building structure at each floor level. Stiffening collars - refer to DW144 If the longer side of the duct is greater than 1500mm, and the ducts have a section length greater than 625mm, then a stiffening collar is required. 1. Fit each collar to the duct at approximately mid-length. The collar should be made to the same size steel section as the cross joints (or equivalent). Suspension system spacing rectangular vertical ducts The maximum vertical distance between supports is 5000mm. 1. Fasten steel sections to the steel duct in order to support the duct system vertically. The maximum vertical distance between supports is 5000mm. 2. The supporting steel members, where they emerge from the protection around the duct, must be clad with the same thickness of insulation for at least 300mm. 2. Weld or bolt the sections together at the corners and fasten to the duct walls with steel rivets (or equivalent) at maximum 300mm centres, or spot-welds at maximum 150mm centres. Rectangular horizontal ducts The maximum distance between supports should not exceed 1250mm. For more information on the Isover Ultimate Protect range, please visit

19 Preparation of ductwork Preparation of circular ductwork prior to insulating Duct sheeting The spirally wound steel duct is constructed in sections up to 3000mm long using hot dipped galvanised steel sheet, mild steel sheet or stainless steel sheet, 0.7mm thick. Thickness of steel sheet 0.7mm 1.0mm Maximum diameter of duct Up to 1000mm Up to 1250mm Maximum duct sizes: 1250mm diameter Drop rods and hangers for circular horizontal ducts Each steel hanger consists of two threaded drop The ends of each band section are bent rods, minimum M8, and a two-part circular band, outwards. Fasten the band sections together 25mm wide x 2mm thick. The maximum spacing and attach to the drop rods with hexagonal of the hangers is 1200mm. nuts and washers. Position the drop rods and bearers inside the insulation material, with the drop rods 10mm from the steel duct. NB: The spacing of the hangers and the size of the steel hanger components must be adjusted so that the tensile stress in the rods and the bands do not exceed 15N/mm 2 for fire resistance periods up to 60 minutes and 10N/mm 2 for fire resistance periods up to 120 minutes. Drop rod anchors When fixing to a concrete supporting construction Use all-steel expanding anchors to fasten the threaded rod hangers to concrete soffits. The drop rod anchors should penetrate the concrete by at least 50mm, to achieve 120 minutes of fire resistance. When fixing to a steel supporting construction Drill a hole through the steel member, allowing the drop rod anchors to be supported by a steel nut and washer above. If a clamp type fixing is used, the clamp must be steel, suitable for the purpose. It should pass around the steel member and be fastened back on itself. NOTE: Clamps that rely on friction to hold them in place are not suitable. Technical enquiries: techinsulation@saint-gobain.com or

20 HVAC - Fire protection of metal ductwork protection Fire insulation Thermal Joints As per HVAC Specification DW144. The spirally wound steel duct is constructed in sections up to 3000mm long using hot dipped galvanised steel sheet, mild steel sheet or stainless steel sheet, 0.7mm thick. The spiral seam of the spirally wound ducts must be the grooved seam, Lindab SR Series or equivalent. Stiffeners Where 120 minutes of fire resistance is required for steel ducts, 40mm x 5mm steel flanges should be positioned approx 10mm from each duct connection. Supports for circular vertical ducts The steel sections either span across the opening in the concrete floor or form part of a cantilever bracket that is fastened to the building structure. The maximum vertical distance between supports is 5000mm. The distance between supports should not exceed eight times the smallest lateral dimension across the outside face of the steel duct, to prevent buckling of the duct. The weight of the duct system is taken by the building structure at each floor level. Suspension system spacing Circular horizontal ducts The maximum distance between supports should not exceed 1200mm. 1. Fasten minimum M4 steel self-tapping screws to the duct at 150mm centres on both sides of the joint, at each cross joint Lindab NPU steel sleeves (or equivalent), minimum size 100mm wide and thickness as per following: 0.6mm up to 500mm diameter 0.7mm from 501mm up to 709mm 0.9mm from 710mm up to 1000mm Flanged connections from mm 2. Fit a sealing strip of EPDM rubber and a ceramic tape gasket, 15mm wide x 3mm thick, between the sleeve and the duct, on both sides of the joint, to seal the joints. 1. Fasten steel sections to the steel duct, either along the two longer sides, or on all four sides. 2. Clad the supporting steel members, where they emerge from the protection around the duct, with the same thickness of insulation for at least 300mm. Circular vertical ducts The maximum vertical distance between supports is 5000mm. For further information on the Isover ULTIMATE Protect range, please contact us on techinsulation@saint-gobain.com or for technical advice please call

21 Technical Insulation Preparation of ductwork including HVAC, Marine and OEM Dedicated Technical Helpline Tel: Advice on >> Compliance with Building Regulations for Pipework and Ductwork solutions >> Consultant performance specifications >> Technical Product range and system applications >> Heat Loss and energy savings calculations

22 Less Materials Less Energy Less Emissions Isover Order Placement or Order Enquiries: Tel: Fax: Publish date: March 2012 Isover Document Reference: FPI-IG Technical Insulation - Technical Enquiries Tel: techinsulation@saint-gobain.com Saint-Gobain Isover UK Commercial Centre Gotham Business Park Leake Road Gotham Nottinghamshire NG11 0LB Tel: Fax: isover@saint-gobain.com Isover reserves the right to revise product specifications without notice. The information in this document was correct to the best of our knowledge at the time of publication. It is the users responsibility to ensure that it remains current prior to use. The information in this document is for guidance only and should not be read in isolation. Users should read and familiarise themselves with all the information contained in this document and ensure that they are fully conversant with the products and systems being used, before subsequent specification or installation. For a comprehensive and up to date library of information visit the Isover website.

Composite Panel Firewall Systems

Composite Panel Firewall Systems Composite Panel Firewall Systems part of the Protecting more than your business Insulated mineral fibre panels have excellent thermal and acoustic properties, ideal for factory and office partition walls.

More information

Services Enclosures and Protected Shafts - Maintaining Compartmentation

Services Enclosures and Protected Shafts - Maintaining Compartmentation Introduction When a fire resisting element is used to provide fire compartmentation, every opening that allows services to pass through the element must be adequately protected by sealing, or fire stopping

More information

Fire Barrier Duct Wrap 15A

Fire Barrier Duct Wrap 15A 3 Fire Barrier Duct Wrap 15A Commerical Kitchen Grease Duct Fire Protection System Product Data and Installation Instructions Compliance 1998 Edition Complies with International Mechanical Code Complies

More information

Fiberglas, Exterior Wall Thermal Insulation

Fiberglas, Exterior Wall Thermal Insulation PROJECT ENGINEER RESPONSIBILITY: This is a general specification guide, intended to be used by experienced construction professionals, in conjunction with good construction practice and professional judgment.

More information

Schlüter -KERDI-BOARD Substrate, structural panel, bonded waterproofing

Schlüter -KERDI-BOARD Substrate, structural panel, bonded waterproofing Substrate, structural panel, bonded waterproofing The universal substrate for tiles Perfect covering No matter whether you work with mosaics or large format tiles, an absolutely level substrate with straight

More information

STRUCTURAL CONCEPT FOR LIGHT GAUGE STEEL FRAME SYSTEM

STRUCTURAL CONCEPT FOR LIGHT GAUGE STEEL FRAME SYSTEM Chapter 9 STRUCTURAL CONCEPT FOR LIGHT GAUGE STEEL FRAME SYSTEM 9.1 BACKGROUND Steel is widely used in the construction of multi-storey buildings. However, steel construction is seldom used and is traditionally

More information

CERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. No VTT C-6044-10 Date of issue 11.10.2010, Updated July 1, 2011

CERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. No VTT C-6044-10 Date of issue 11.10.2010, Updated July 1, 2011 CERTIFICATE NAME OF PRODUCT No VTT C-6044-10 Date of issue 11.10.2010, Updated July 1, 2011 H-CONTROL REFLEX+ reflective insulating vapour control layer for roof and wall applications MANUFACTURER ACTIS

More information

lindab duct suspension & support system Duct suspensions & Support systems

lindab duct suspension & support system Duct suspensions & Support systems lindab duct suspension & support Duct suspensions & Support s lindab duct suspension & support Content Duct suspensions & Support s Duct suspension Duct suspension FB... DRSN... 0 DRSNR... 0 Channels and

More information

Passive Fire Protection

Passive Fire Protection Firestopping Passive Fire Protection FS20 Firestop Compound 6 hour fire rated penetration seals for electrical and mechanical services FS20 Firestop Compound FS20 Firestop Compound is a Fire-Rated Penetration

More information

Rockwool Cladding Roll

Rockwool Cladding Roll Rockwool Cladding Roll High performance industrial insulation has been specifically developed for use in lightweight cladding applications to commercial or industrial framed buildings. Cladding Roll U/F

More information

Saferand easierinstallation

Saferand easierinstallation EN 85-07 Saferand easierinstallation IföSigninstallationsystem andifösignbuilt-incistern www.ifosanitar.com/sign Aneffectivesolution withmanyadvantages. Ifö Sign installation system makes life a little

More information

ENVIRONMENTAL INFORMATION APR 1200 products are made from glass mineral wool, one of the most environmentally friendly insulants available.

ENVIRONMENTAL INFORMATION APR 1200 products are made from glass mineral wool, one of the most environmentally friendly insulants available. APR 1200 Acoustic Partition Roll CI/Sfb Ref: APR002 Glass mineral wool roll designed to provide high levels of sound insulation in walls and floors to meet Part E (England & Wales) and Section 5 (Scotland)

More information

Fire Barrier Systems. For inhibiting the spread of fire and smoke in concealed spaces

Fire Barrier Systems. For inhibiting the spread of fire and smoke in concealed spaces CI/SfB Km1 (K22) November 2006 (replaces July 2005 issue) Construction type Cavity Barriers Fire Barrier Systems For inhibiting the spread of fire and smoke in concealed spaces As part of the comprehensive

More information

1.2.1 1.1.8 PRODUCTBLADEN GT ROCKPANEL STRUCTURE

1.2.1 1.1.8 PRODUCTBLADEN GT ROCKPANEL STRUCTURE 1..1 1.1.8 PRODUCTBLADEN SHEETS GT page 1 to 6 Rockpanel Structure is a very durable panel with a lightly textured finish, specially developed for use in cladding, fascia, soffit applications. The basic

More information

C05. S03. P02 P08 FireWall. Including C05. S01. P02 Specialist partitions introduction

C05. S03. P02 P08 FireWall. Including C05. S01. P02 Specialist partitions introduction C05. S03. P02 P08 Including C05. S01. P02 Specialist partitions introduction C05 Specialist partitions Introduction Specialist partitions This section details specialist lightweight systems where high-security,

More information

Consultants Handbook

Consultants Handbook Consultants Handbook CONSULTANTS HANDBOOK Welcome to our Wallis Designers Lightning Protection Handbook. This handbook offers a guide for any designers of the structural Lightning protection system to

More information

CERTIFICATE OF APPROVAL No CF 5055 ARABIAN VERMICULITE INDUSTRIES

CERTIFICATE OF APPROVAL No CF 5055 ARABIAN VERMICULITE INDUSTRIES CERTIFICATE OF APPROVAL No CF 5055 This is to certify that, in accordance with TS00 General Requirements for Certification of Fire Protection Products The undermentioned products of 1 st Industrial Area,

More information

Guidelines for Earthquake Bracing of Residential Water Heaters

Guidelines for Earthquake Bracing of Residential Water Heaters Guidelines for Earthquake Bracing of Residential Water Heaters Department of General Services Division of the State Architect 1102 Q Street, Suite 5100 Sacramento, CA 95814 Phone: (916) 324-7099 Fax: (916)

More information

PRE-ASSEMBLED INSTALLATION INSTRUCTIONS FOR PACB SERIES COAL FIRED OVENS

PRE-ASSEMBLED INSTALLATION INSTRUCTIONS FOR PACB SERIES COAL FIRED OVENS PRE-ASSEMBLED INSTALLATION INSTRUCTIONS FOR PACB SERIES COAL FIRED OVENS OVENS MANUFACTURED BY: EARTHSTONE OVENS-6717 SAN FERNANDO RD GLENDALE CA 91201 TELEPHONE: 800-840-4915 818-553-1134 FAX: 818-553-1133

More information

Installation Details. D1 General D2 Walls D3 Ceilings D4 Reference. D Installation Details

Installation Details. D1 General D2 Walls D3 Ceilings D4 Reference. D Installation Details D Installation Details D1 General D2 Walls D3 Ceilings D4 Reference D Installation Details D Contents D1 General Installation and Fastening Sequence for Steel Studs D1.1 Fastener Selection D1.3 D2 Walls

More information

Guidelines for Earthquake Bracing Residential Water Heaters

Guidelines for Earthquake Bracing Residential Water Heaters Guidelines for Earthquake Bracing Residential Water Heaters Department of General Services Division of the State Architect In accordance with the Health and Safety Code Section 19215, the Division of the

More information

Residential Deck Safety, Construction, and Repair

Residential Deck Safety, Construction, and Repair Juneau Permit Center, 4 th Floor Marine View Center, (907)586-0770 This handout is designed to help you build your deck to comply with the 2006 International Residential Building code as modified by the

More information

Pipe Clamps and Accessories

Pipe Clamps and Accessories Products 4.0 Products 4.1 Connection options to pipe clamps with Triple-Thread Connector NT 3G (M16, M10, M8) 4.2 Connection options to pipe clamps with Triple-Thread Connector NT 3G (3/8", M12, M10) 4.3

More information

Excerpts from the Canadian National Building Code (NBC)

Excerpts from the Canadian National Building Code (NBC) Excerpts from the Canadian National Building Code (NBC) Reproduced here with Permission of the Copyright Owner, the National Research Council of Canada, Institute for Research in Construction. For more

More information

PANELIZED HOME INSTALLATION GUIDELINE

PANELIZED HOME INSTALLATION GUIDELINE PANELIZED HOME INSTALLATION GUIDELINE A typical home package will be constructed of Snap-N-Lock Insulated Panels clad with steel skins. 4" panels will be used for the walls, and 6" panels for the roof.

More information

12.1 Schlüter -KERDI-BOARD

12.1 Schlüter -KERDI-BOARD I n n o v a t i v e p r o f i l e s 12.1 Schlüter -KERDI-BOARD S u b s t r a t e U N I V E R S A L S T R U C T U R A L P A N E L, B O N D E D W A T E R P R O O F I N G Application and Function Schlüter

More information

4 Installation Requirements

4 Installation Requirements 4 Installation Requirements 9 4.1 Code Reference The authority having jurisdiction should be referenced to determine what law, ordinance or code shall apply in the use of flexible duct. Ducts conforming

More information

sound reduction systems for commercial, educational and industrial environments

sound reduction systems for commercial, educational and industrial environments sound reduction systems for commercial, educational and industrial environments Tel: +44 ()14 3874 Fax: +44 ()14 38957 E-mail: info@soundreduction.co.uk Web: www.soundreduction.co.uk soundblocker Acoustic

More information

INTERNATIONAL ASSOCIATION OF CLASSIFICATION SOCIETIES. Interpretations of the FTP

INTERNATIONAL ASSOCIATION OF CLASSIFICATION SOCIETIES. Interpretations of the FTP INTERNATIONAL ASSOCIATION OF CLASSIFICATION SOCIETIES Interpretations of the FTP CONTENTS FTP1 Adhesives used in A or B class divisions (FTP Code 3.1, Res A.754 para. 3.2.3) June 2000 FTP2 Pipe and duct

More information

ModuSec. Secure and efficient IT room solutions Composite Panel Systems Compared. Panel Systems are not all the same!

ModuSec. Secure and efficient IT room solutions Composite Panel Systems Compared. Panel Systems are not all the same! Secure and efficient IT room solutions Composite Panel Systems Compared Panel Systems are not all the same! When it comes to accommodating critical IT systems, the first issue to look at is the environment

More information

INSTALLATION OF A BAY WINDOW

INSTALLATION OF A BAY WINDOW INSTALLATION OF A BAY WINDOW Installation of a Bay Window These instructions relate to the replacement of an existing bay window or replacement of a straight window with a new bay window, in an opening

More information

Roof Curbs, Extensions and Equipment Supports

Roof Curbs, Extensions and Equipment Supports Roof s, Extensions and Equipment Supports December 2012 Roof Page s, Header Extensions and Equipment Supports Table of Contents Model GPI Standard and Optional Construction Features... 3 Model Number Code....

More information

Rockwool Flexi Insulation Application Guide

Rockwool Flexi Insulation Application Guide Pitched roof Rafters InterMediate floors INTERNAL partitions external Framed walls separating floors Separating Walls Rockwool Flexi Insulation Application Guide Ground floor The perfect fit for any framed

More information

UNIVERSAL RAILING, STEEL

UNIVERSAL RAILING, STEEL RAILINGS Page Universal Railing, steel 108-109 Large Module Railing, steel 110-111 Allround Railing, aluminium 112-113 Module Railing, aluminium 114-115 Standard Type Railing, aluminium 116-117 107 UNIVERSAL

More information

STANDARD SPECIFICATION. for. Plumbing, Heating, Hot Water, Cold Water & Electrical work. Sussex Lodge London W2 & 16 Stanhope Terrace London W2

STANDARD SPECIFICATION. for. Plumbing, Heating, Hot Water, Cold Water & Electrical work. Sussex Lodge London W2 & 16 Stanhope Terrace London W2 STANDARD for Plumbing, Heating, Hot Water, Cold Water & Electrical work undertaken by owners within the building known as Sussex Lodge London W2 & 16 Stanhope Terrace London W2 BPME Consulting Engineers

More information

GUIDELINES FOR INSTALLATION OF AIR CONDITIONING UNITS 174-180 PHILLIP STREET, SYDNEY

GUIDELINES FOR INSTALLATION OF AIR CONDITIONING UNITS 174-180 PHILLIP STREET, SYDNEY GUIDELINES FOR INSTALLATION OF AIR CONDITIONING UNITS 174-180 PHILLIP STREET, SYDNEY July 2008 1.0 SCOPE These guidelines describe the way in which air conditioning units shall be installed or replaced

More information

CEILING SYSTEMS. CI/SfB (35) Xy April 2006. [Between us, ideas become reality.] ULTIMA CANOPY. Data sheet. Acoustic performance meets High Design

CEILING SYSTEMS. CI/SfB (35) Xy April 2006. [Between us, ideas become reality.] ULTIMA CANOPY. Data sheet. Acoustic performance meets High Design CEILING SYSTEMS [Between us, ideas become reality.] CI/SfB (35) Xy April 2006 ULTIMA CANOPY Data sheet Acoustic performance meets High Design ULTIMA CANOPY Installation Instructions I. GENERAL 1. Product

More information

Product Data Sheet ROCKPANEL Rockclad

Product Data Sheet ROCKPANEL Rockclad Product Data Sheet ROCKPANEL Rockclad Durable - Xtreme - FS-Xtra United Kingdom 1 Product description ROCKPANEL boards are prefabricated compressed mineral wool boards with synthetic binders. The surface

More information

SECTION 23 05 29 - HANGERS AND SUPPORTS FOR HVAC PIPING AND EQUIPMENT

SECTION 23 05 29 - HANGERS AND SUPPORTS FOR HVAC PIPING AND EQUIPMENT SECTION 23 05 29 - HANGERS AND SUPPORTS FOR HVAC PIPING AND EQUIPMENT PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Pipe hangers and supports. 2. Hanger rods. 3. Inserts. 4. Flashing. 5. Equipment

More information

Built to Last. Built for Beauty. Good. Solid. Logix. TM

Built to Last. Built for Beauty. Good. Solid. Logix. TM Built to Last. Built for Beauty. Good. Solid. Logix. TM Quality, Value and Service Introducing LOGIX Insulated Concrete Forms. Based on the simple concept of interlocking blocks, LOGIX ICF gives you a

More information

Detailing of Reinforcment in Concrete Structures

Detailing of Reinforcment in Concrete Structures Chapter 8 Detailing of Reinforcment in Concrete Structures 8.1 Scope Provisions of Sec. 8.1 and 8.2 of Chapter 8 shall apply for detailing of reinforcement in reinforced concrete members, in general. For

More information

Certification of construction products - Fire dampers. Certification Rules 032

Certification of construction products - Fire dampers. Certification Rules 032 Certification of construction products - Fire dampers Certification Rules 032 1 Contents Contents 1 0 Preface 1 1 Scope and intended application 2 2 Technical requirements 2 2.1 Properties 2 2.1.1 Protection

More information

INSTALLATION INSTRUCTIONS AIRCOMMAND IBIS ROOFTOP AIRCONDITIONER

INSTALLATION INSTRUCTIONS AIRCOMMAND IBIS ROOFTOP AIRCONDITIONER \ INSTALLATION INSTRUCTIONS AIRCOMMAND IBIS ROOFTOP AIRCONDITIONER Suitability: The IBIS caravan rooftop aircondioner is suitable for installation on caravans and motorhomes provided the roof structure

More information

Since it was established in 1989, with a small manufacturing base in Qwa Qwa and a hire yard in Botswana, Uni-Span

Since it was established in 1989, with a small manufacturing base in Qwa Qwa and a hire yard in Botswana, Uni-Span formwork formwork Since it was established in 1989, with a small manufacturing base in Qwa Qwa and a hire yard in Botswana, Uni-Span has grown to become one of the major players in the scaffolding and

More information

Schluter -KERDI-BOARD Substrate, building panel, bonded waterproofing

Schluter -KERDI-BOARD Substrate, building panel, bonded waterproofing Schluter -KERDI-BOARD Substrate, building panel, bonded waterproofing Schluter -KERDI-BOARD The universal substrate for tiles Flat. Level. Plumb. Square. No matter the quality, cost, or extravagance of

More information

plumbing products guide

plumbing products guide plumbing products guide radiator pipe guide & seals A significant development in the drive to reduce air leakage and heat loss. Installations such as that shown are all too common. The detail is poorly

More information

BETONYP building boards. The modern way of living.

BETONYP building boards. The modern way of living. BETONYP building boards The modern way of living. Tough for 30 years. Healthy, debarked pine wood and cement: the raw materials used to produce one of our most successful products for more than three decades.

More information

Linea Weatherboard DIRECT FIX CONCRETE SLAB AND SOFFIT FIGURE 1

Linea Weatherboard DIRECT FIX CONCRETE SLAB AND SOFFIT FIGURE 1 Top plate Stud Soffit lining 45mm min nog Fix scotia bead Building underlay/james Hardie rigid air barrier Soffit Detail Building underlay/james Hardie rigid air barrier Bottom plate 25mm wide cant strip.

More information

Free piston Stirling engine for rural development

Free piston Stirling engine for rural development Free piston Stirling engine for rural development R. Krasensky, Intern, Stirling development, r.krasensky@rrenergy.nl W. Rijssenbeek, Managing director, w.rijssenbeek@rrenergy.nl Abstract: This paper presents

More information

Incorporating V2.3. Product spec >>> > Series ECG - Egg Crate Grilles. > Series ECG45-45 Egg Crate Grilles

Incorporating V2.3. Product spec >>> > Series ECG - Egg Crate Grilles. > Series ECG45-45 Egg Crate Grilles Incorporating V2.3 Product spec >>> > Series ECG - Egg Crate Grilles > Series ECG45-45 Egg Crate Grilles Grilles Egg crate Recommended for: Wall, ceiling & duct Extract Overview Industry standard extract

More information

PART 1 GENERAL 1.1 SECTION INCLUDES

PART 1 GENERAL 1.1 SECTION INCLUDES J-1 Section 09110 Long Form Specification INTERIOR METAL STUD FRAMING This section includes lightweight, usually 0.036 inch (0.9 mm) thick or lighter, non-axial load bearing metal stud framing including

More information

Marine & Offshore Insulation. - products and constructions November 2009

Marine & Offshore Insulation. - products and constructions November 2009 Marine & Offshore Insulation - products and constructions November 2009 Marine and offshore insulation worldwide For many years ROCKWOOL Marine & Offshore has been one of the leading suppliers marine and

More information

!!!!!! !!! Decra Plus DPSW010 DPSTW011 DPSW012 DPSW013 DPSW014 DPSW015 DPSW016 DPSW020 DPSW021 DPSW024 DPSW030 DPSW031 DPSW035 DPSW030 DPSW031 DPSW035

!!!!!! !!! Decra Plus DPSW010 DPSTW011 DPSW012 DPSW013 DPSW014 DPSW015 DPSW016 DPSW020 DPSW021 DPSW024 DPSW030 DPSW031 DPSW035 DPSW030 DPSW031 DPSW035 Decra Plus Drawing no DPSW010 DPSTW011 DPSW012 DPSW013 DPSW014 DPSW015 Description Shown In Decra Brochure Most Commonly Used Detail t~êã=oççñ=b~îéë=aéí~áä=b~îéë=lîéêü~åö=táíü=fåëìä~íéç=c~ëåá~=~åç=pçññáí

More information

Fire 2This Technical Bulletin has been commissioned by the UK SIP Association in

Fire 2This Technical Bulletin has been commissioned by the UK SIP Association in REV 1-12.12.11/TB002 Technical Bulletin Fire 2This Technical Bulletin has been commissioned by the UK SIP Association in conjunction with TRADA Technology and is intended to provide the reader with introductory

More information

Product Information Sheet

Product Information Sheet Product Information Sheet FyreWrap MAX 2.0 Duct Insulation Two-Layer ASTM E-2336 System Introduction Unifrax s is a hightemperature insulation blanket specifically designed to provide a flexible enclosure

More information

FSD35, FSD36 AND FSD37 COMBINATION FIRE and SMOKE DAMPERS

FSD35, FSD36 AND FSD37 COMBINATION FIRE and SMOKE DAMPERS 3900 Dr. Greaves Rd. Kansas City, MO 64030 (816) 761-7476 FAX (816) 765-8955 INSTALLATION INSTRUCTIONS FSD35, FSD36 AND FSD37 COMBINATION FIRE and SMOKE DAMPERS 11/2 HOUR UL555 RATED UL555S LEAKAGE RATED

More information

Window Installation Instructions

Window Installation Instructions Caution The correct installation methods of windows in full frame or insert applications is critical towards achieving the tested performance of the window and longterm enjoyment and energy savings for

More information

(This report is endorsed) Industrivej 20, 9900 Frederikshavn, Danmark

(This report is endorsed) Industrivej 20, 9900 Frederikshavn, Danmark Spectrum Laboratories Ltd is accredited by International Accreditation New Zealand (formerly Telarc). The tests reported herein have been performed in accordance with the terms of our accreditation. This

More information

TECHNICAL SPECIFICATION SERIES 8000 PRECAST CONCRETE

TECHNICAL SPECIFICATION SERIES 8000 PRECAST CONCRETE TECHNICAL SPECIFICATION SERIES 8000 PRECAST CONCRETE TECHNICAL SPECIFICATION PART 8000 - PRECAST CONCRETE TABLE OF CONTENTS Item Number Page 8100 PRECAST CONCRETE CONSTRUCTION - GENERAL 8-3 8101 General

More information

Decree of the Ministry of the Environment on fire safety of ventilation systems

Decree of the Ministry of the Environment on fire safety of ventilation systems THE NATIONAL BUILDING CODE OF FINLAND MINISTRY OF THE ENVIRONMENT Housing and Building Department Decree of the Ministry of the Environment on fire safety of ventilation systems Adopted in Helsinki, 18

More information

Enclosures 1-866-338-0988. DuraSystems Barriers, Inc. www.durasystems.com Email: sales@durasystems.com. The Passive Fire Protection Specialists

Enclosures 1-866-338-0988. DuraSystems Barriers, Inc. www.durasystems.com Email: sales@durasystems.com. The Passive Fire Protection Specialists Enclosures Sturdy single and double wall fire protection construction Impact resistant Fast & easy installation Pre-manufactured and modular Available in galvanized, stainless steel & other specialty metals

More information

How To Repair A Boat Landing Deck With A Boat Bed

How To Repair A Boat Landing Deck With A Boat Bed RESIDENTIAL INSULATED SHEATHING INSTALLATION GUIDE Residential Insulated Sheathing Installation Guide ROXUL COMFORTBOARD IS Table of Contents Slab-on-grade-to Above Grade Wall...1 Foundation Wall at Footing

More information

lindab duct suspension & support system Duct suspensions & Support systems

lindab duct suspension & support system Duct suspensions & Support systems lindab duct suspension & support system Duct suspensions & Support systems lindab duct suspension & support system Content Duct suspensions & Support systems Duct suspension Threaded rod OSB 0... Channels

More information

Owner's Manual & Assembly Instructions

Owner's Manual & Assembly Instructions Owner's Manual & Assembly Instructions PM01 BASE KIT Model No. FDN1014 717090311 CAUTION: SOME PARTS HAVE SHARP EDGES. CARE MUST BE TAKEN WHEN HANDLING THE VARIOUS PIECES TO AVOID A MISHAP. FOR SAFETY

More information

MultiPost-AP anchorage device

MultiPost-AP anchorage device MultiPost-AP anchorage device MultiPost anchorage point Type 1 Fixing on reinforced concrete with large, 360 rotating stainless steel lifting eye for the simultaneous securing of max. 2 persons. This can

More information

Product Information Sheet

Product Information Sheet Distributed by Thermal Products Company, Inc. Product Information Sheet FyreWrap Elite 1.5 Duct Insulation Air Distribution System (ADS Ducts) Introduction Unifrax s FyreWrap Elite 1.5 Duct Insulation

More information

Multi-layer Insulation Blanket for Roofs

Multi-layer Insulation Blanket for Roofs Multilayer Insulation Blanket for Roofs Thermal Insulation in a 40mm thin, flexible, multilayer membrane Meets requirements of L1A, L1B 2010 In accordance with BR443 NHBC Acceptance Pitched & Flat roof

More information

March 14, 2007. Installation of Bay, Bow and Garden Windows

March 14, 2007. Installation of Bay, Bow and Garden Windows March 14, 2007 Re: Installation of Bay, Bow and Garden Windows Attached are the Atrium Companies, Inc recommendation for the installation of bay, bow and garden windows. These instructions were developed

More information

PRESENTATION ON REPAIR AND REHABILITATION OF BUILDINGS DAMAGED IN EARTHQUAKE. By H P Gupta & D K Gupta

PRESENTATION ON REPAIR AND REHABILITATION OF BUILDINGS DAMAGED IN EARTHQUAKE. By H P Gupta & D K Gupta PRESENTATION ON REPAIR AND REHABILITATION OF BUILDINGS DAMAGED IN EARTHQUAKE By H P Gupta & D K Gupta DIFFERENT TYPES OF DAMAGES 1.Minor cracks 0.5 to 5 mm wide in load or non-load bearing walls 2.Major

More information

SECTION 15140 - PIPE HANGERS AND SUPPORTS

SECTION 15140 - PIPE HANGERS AND SUPPORTS Part I - GENERAL 1.01 SECTION INCLUDES A. The work covered under this section consists of the furnishing of all necessary labor, supervision, materials, equipment, and services to completely execute the

More information

Fire Collars For Plastic Pipe Penetration

Fire Collars For Plastic Pipe Penetration Fire Collars For Plastic Pipe Penetration PROMASEAL Retrofit Collars FCS/FC FCS FC PROMASEAL fire collars are purpose made painted steel shells with integral mounting points, containing a specially formulated

More information

Building Envelope Design by Roxul (BEDR ) FireWall and Roxul Plus MB. Fire Rated Board Insulation for Pre-Engineered Metal Buildings

Building Envelope Design by Roxul (BEDR ) FireWall and Roxul Plus MB. Fire Rated Board Insulation for Pre-Engineered Metal Buildings BUILDING ENVELOPE DESIGN BY ROXUL Building Envelope Design by Roxul (BEDR ) FireWall and Roxul Plus MB Fire Rated Board Insulation for Pre-Engineered Metal Buildings ROXUL FIREWALL & ROXUL PLUS MB Exterior

More information

PASSIVE FIRE PROTECTION SYSTEMS Application & Technical Manual: Ceilings & Floors

PASSIVE FIRE PROTECTION SYSTEMS Application & Technical Manual: Ceilings & Floors PASSIVE FIRE PROTECTION SYSTEMS Application & Technical Manual: Ceilings & Floors For distribution in Asia Pacific PASSIVE FIRE PROTECTION SYSTEMS Application & Technical Manual: Ceilings & Floors Contents

More information

DRAINAGE MATS For Vertical: Flow 15-P For Horizontal: Flow 18-H

DRAINAGE MATS For Vertical: Flow 15-P For Horizontal: Flow 18-H DRAINAGE MATS For Vertical: Flow 15-P For Horizontal: Flow 18-H Soil Drainage Mat with Built-In Protection Layer POLYGUARD DRAINAGE MATS are three-part prefabricated geocomposite drain consisting of a

More information

Cavity Drain R20 is manufactured from1.0mm thick black high density polyethylene with studs approximately 20mm high.

Cavity Drain R20 is manufactured from1.0mm thick black high density polyethylene with studs approximately 20mm high. CI/SfB Tn6 L6813 September 2013 RIW CAVITY DRAIN R20 R20 is manufactured from1.0mm thick black high density polyethylene with studs approximately 20mm high. Other systems are available for specific uses,

More information

usg.com/me USG Middle East, Ltd. Dammam, Saudi Arabia E-mail: info@usgme.com Fax: +966 3 8121029 +966 3 8120995

usg.com/me USG Middle East, Ltd. Dammam, Saudi Arabia E-mail: info@usgme.com Fax: +966 3 8121029 +966 3 8120995 USG Middle East, Ltd. Dammam, Saudi Arabia E-mail: info@usgme.com Fax: +966 3 8121029 +966 3 8120995 Riyadh, Saudi Arabia E-mail: riyadhsales@usgme.com Fax: +966 1 4772734 +966 1 4772734 Jeddah, Saudi

More information

PROPOSED SPECIFICATION FOR ALUCOBOND PLUS Aluminium Composite Panel Cladding System Fixed Watertight Cassette Panel System - 4mm thick

PROPOSED SPECIFICATION FOR ALUCOBOND PLUS Aluminium Composite Panel Cladding System Fixed Watertight Cassette Panel System - 4mm thick 1. SCOPE OF WORK The scope of work includes the design, supply fabrication and installation of Alucobond PLUS aluminium composite panel cladding, complete with all necessary sub-structures, anchors, hardware

More information

Timber Decks. Technical Note. March 2007

Timber Decks. Technical Note. March 2007 Timber Decks Technical Note. March 2007 This Technical Note contains general information for residential timber decks and floor frame structures for veranda s, patios etc which are exposed to the weather.

More information

HOTCHKISS AIR SUPPLY Heating, Ventilating & Air Movement Equipment

HOTCHKISS AIR SUPPLY Heating, Ventilating & Air Movement Equipment HOTCHKISS AIR SUPPLY Heating, Ventilating & Air Movement Equipment F l a t O v a l T u b e a n d F i t t i n g s Introduction Hotchkiss Flat Oval ductwork offers all the advantages of rectangular ducts

More information

HORIZONTAL INSTALLATION

HORIZONTAL INSTALLATION THERMO/SOLAR Žiar s.r.o. MANUAL FOR INSTALLATION PV SUPPORTING FRAMES HORIZONTAL INSTALLATION Technical alternation reserved A1410 1 12/2014 CONTENT ORD.NO. PAGE Mounting information 3 Mounting, flat roof

More information

WTW SWANTM. Linear slot air diffusers of wall-to-wall design for ceilings

WTW SWANTM. Linear slot air diffusers of wall-to-wall design for ceilings SWANTM WTW Linear slot air diffusers of wall-to-wall design for ceilings Quick facts Wall-to-wall installation Diffuser face of light aluminium design 2, 3 or slots Horizontal/vertical air distribution

More information

DESIGN AND INSTALLATION OF RESIDENTIAL FLEXIBLE DUCTWORK SYSTEMS

DESIGN AND INSTALLATION OF RESIDENTIAL FLEXIBLE DUCTWORK SYSTEMS DESIGN AND INSTALLATION OF RESIDENTIAL FLEXIBLE DUCTWORK SYSTEMS A. SCOPE 1. This information is intended to assist contractors, installers and code officials in the proper design and installation of flexible

More information

Fire safety in timber buildings

Fire safety in timber buildings Fire safety in timber buildings Introduction Fire spread in buildings is a risk to life safety for which the Building Regulations (for England and Wales 1,2, Scotland 3 and Northern Ireland 4 ) aims to

More information

MRI RF SHIELDING DESIGN

MRI RF SHIELDING DESIGN MRI RF SHIELDING DESIGN Nelco s MRI RF Shielding is specifically designed for the MRI industry. Our engineers have developed a shielded enclosure made entirely of nonmagnetic materials that is unsurpassed

More information

39HQ Airovision Air Handling Units

39HQ Airovision Air Handling Units 39HQ Airovision Air Handling Units Mounting instructions CONTENTS 1 - TRANSPORT AND LIFTING INSTRUCTIONS... 3 1.1 - General... 3 1.2 - Transport and storage... 3 1.3 - Roof edge protection during transport

More information

Partitioning & Ceiling Product Information

Partitioning & Ceiling Product Information Partitioning & Ceiling Product Information tel + 44 (0) 1384 412448 fax + 44 (0) 1384 4494 email enquiries@drywallsteelsections.co.uk web www.drywallsteelsections.co.uk tel + 44 (0) 1384 412448 fax + 44

More information

Cooktop Low-Profile Ventilation Hoods

Cooktop Low-Profile Ventilation Hoods INSTALLATION GUIDE Cooktop Low-Profile Ventilation Hoods Contents Wolf Cooktop Low-Profile Ventilation Hoods........ 3 Cooktop Low-Profile Hood Specifications.......... 4 Cooktop Low-Profile Hood Installation............

More information

Hanson Building Products. precast basement solutions

Hanson Building Products. precast basement solutions Hanson Building Products precast basement solutions Hanson Building Products Basement Systems Add an extra dimension and combine the inherent flexible, structural and waterproof properties of concrete

More information

Section 2.4. Built-up Metal Roofs. Rail and bracket system. Standing seam system. Bu02. Product: Earthwool FactoryClad range Bu01

Section 2.4. Built-up Metal Roofs. Rail and bracket system. Standing seam system. Bu02. Product: Earthwool FactoryClad range Bu01 Section Built-up Metal Roofs Rail and bracket system Product: Earthwool FactoryClad range Bu01 Standing seam system Product: Earthwool FactoryClad range and Earthwool Universal Slab Bu02 Built-up Metal

More information

Fire-resistance test on fire collars protecting a concrete slab penetrated by services

Fire-resistance test on fire collars protecting a concrete slab penetrated by services INFRASTRUCTURE TECHNOLOGIES Fire-resistance test on fire collars protecting a concrete slab penetrated by services Test Report Author: Mario Lara Report number: FSP 1614 Date: 14 February 2014 Client:

More information

James M. Pleasants Company

James M. Pleasants Company James M. Pleasants Company SUBMITTAL DATA GAINESVILLE MECHANICAL DECEMBER 20, 2013 PROJECT: GSU: J-183 HUMANITIES LAW BLDG. QUOTE NO:12116 ENGINEER: STEVENS & WILKINSON GASKETED PLATE HEAT EXCHANGER Tag:

More information

PB301 July 2009. Lightweight Building Solutions. Bushfire Protection. www.boral.com.au/bushfireprotection

PB301 July 2009. Lightweight Building Solutions. Bushfire Protection. www.boral.com.au/bushfireprotection PB301 July 2009 Lightweight Building Solutions Bushfire Protection www.boral.com.au/bushfireprotection Attached or adjacent within 6m roofed structures such as garages, carports, verandas and the like,

More information

60.12. Depend-O-Lok FxE Expansion Coupling. System No. Submitted By Spec Sect Para Location Date Approved Date. DEPEND-O-LOK FxE EXPANSION COUPLING

60.12. Depend-O-Lok FxE Expansion Coupling. System No. Submitted By Spec Sect Para Location Date Approved Date. DEPEND-O-LOK FxE EXPANSION COUPLING 60.1 D-O-L FxE expansion couplings are a bolted, split-sleeve design that provides for expansion and contraction at the coupled joint. These couplings are furnished with restraint rings that, when affixed

More information

Edition: Export Published: 09/2010. Product catalogue. Technical and industrial insulation. Lapinus

Edition: Export Published: 09/2010. Product catalogue. Technical and industrial insulation. Lapinus Edition: Export Published: 09/2010 Product catalogue Technical and industrial insulation by by RTI, excellence in fi resafe solutions Rockwool Technical Insulation (RTI) - an independent organisation within

More information

SERIES ASM NEOPRENE/EPMD FLANGED SINGLE SPHERE CONNECTOR CONNECTORS. Pressures to 225 PSIG (15.51 barg) Temperatures to 230ºF (110ºC)

SERIES ASM NEOPRENE/EPMD FLANGED SINGLE SPHERE CONNECTOR CONNECTORS. Pressures to 225 PSIG (15.51 barg) Temperatures to 230ºF (110ºC) APPLICATIONS Process Industry Weak Acids Alkalies Compressed Air Pulp & Paper MODELS ASM - Flanged Connection OPTIONS Control Rods Oil & Gas Water & Waste Pump suction & discharge Sea water Chemical lines

More information

Syphonic Roof Drainage

Syphonic Roof Drainage Page 1 T E C H N O L O G Y 2:39 pm Syphonic Roof Drainage P L U M B I N G 23/5/03 A D V A N C E D Prod & Price Gd.for PDF Product Guide SYPHONICS Advanced Roof Drainage Technology Geberit Syphonics Geberit

More information

Profiles in stock Standard catalogue. Discover the possibilities with aluminium profiles from Sapa

Profiles in stock Standard catalogue. Discover the possibilities with aluminium profiles from Sapa Profiles in stock Standard catalogue Discover the possibilities with aluminium from Sapa You can create your own profile or you can choose from a wide selection of standard. Delivery: 1 2 weeks for standard

More information

GK Packing System Welding Instructions

GK Packing System Welding Instructions GK Packing System Welding Instructions Roxtec GmbH Neuer Höltigbaum 1-3, 22143 Hamburg GERMANY Tel +49 (040) 657398-0, Fax +49 (040) 657398-50 EMAIL info@de.roxtec.com, www.roxtec.de Welding instructions

More information