1 CURRENT TRANSFORMER MODEL J " x 7" PAGE No 2-2 REV 8DEC00 TERMINAL OPTION LEAD WIRE OPTION 8-2 BRASS SCREW TERMINALS (2 PLACES) SEE NOTE Ø 2 9 (4 PLACES) UL 05 #6 AWG LEAD WIRE, STANDARD LENGTH IS 24" H H X OPTIONAL MOUNTING PLATE BONDED TO TRANSFORMER NOTES ). ALL DIMENSIONS IN INCHES 2). ALL DIMENSIONS REF ONLY ). HT = -/2 FOR RATIOS UP TO 750:5A HT = -/8 FOR RATIOS 750:5A to 000:5A HT = -/8 FOR RATIOS ABOVE 000:5A Specifications Secondary sources 5 amps AC at rated F.S. primary current Nominal operating frequency range is HZ Thermal rating factor 0C for all ratios Insulation voltage class is 0.6KV BIL 0KV For indoor applications only Reference documents IEEE C57., UL244, CSA CAN-C-M8, and IEC 44- Enclosure is multi-layer tape buildup with heavy vinyl finish, color is black Optional plate is XX phenolic UL and Canadian UL Recognized Component. File E575 Options, contact Factory for information 2.0, 5.0, and 0 VAC output at F.S. primary amperage. Other non - standard ratings also available., 0.2, and 0. A output at F.S. primary amperage. Other nonstandard ratings also available 8-2 Screw Terminals or #6 AWG UL 05 Lead Wires Custom lead wire lengths and types Thermal ratings above. for selected ratios. Available with BB4 bus bar brackets. See Bracket Data Section for dimensions.

2 " x 7" PAGE No 2- CURRENT TRANSFORMER MODEL J REV 8DEC TYPICAL EXCITATION CURVE for MODEL J at 60HZ 0 INDUCED VOLTAGE (volt) :5 2500:5A 000:5A 200:5A 500:5A 0:5 400:5A EXCITING CURRENT (amp) NUMBER * J xxx J xxx J xxx J-0-00-xxx J xxx J xxx J xxx J xxx J xxx J xxx J xxx J xxx J xxx RATIO 400:5A 500:5A 600:5A 0:5A 200:5A 500:5A 600:5A 2500:5A 000:5A 60HZ ± % BURDEN (VA) NOMINAL WINDING RESISTANCE (ohm) * "xxx" describes termination: "T" FOR BRASS SCREW TERMINALS and "Lyyy" FOR LEAD WIRES (Where "yyy" is the lead length in inches. For example, "L24" represents 24 inch long lead wires.)

3 CURRENT TRANSFORMER MODEL J -/4" x -/4" PAGE No 2-4 REV 8DEC BRASS SCREW TERMINAL (2 PLACES) -/ Ø 2 9 (4 PLACES) H -/4 -/4 5 6 X NOTES ). ALL DIMENSIONS IN INCHES 2). ALL DIMENSIONS REF ONLY OPTIONAL MOUNTING PLATE BONDED TO TRANSFORMER Specifications Secondary sources 5 amps AC at rated F.S. primary current Nominal operating frequency range is HZ Thermal rating factor 0C for all ratios Insulation voltage class is 0.6KV BIL 0KV For indoor applications only Reference documents IEEE C57., UL244, CSA CAN-C-M8, and IEC 44- Enclosure is multi-layer tape buildup with heavy vinyl finish, color is black Optional plate is XX phenolic Options, contact Factory for information 2.0, 5.0, and 0 VAC output at F.S. primary amperage. Other non - standard ratings also available. A output at F.S. primary amperage. Other non-standard ratings also available Thermal ratings above. for selected ratios 8-2 Screw Terminals or #6 AWG UL 05 Lead Wires Custom lead wire lengths and types Available with B7 bus bar brackets. See Bracket Data Section for dimensions.

4 -/4" x -/4" PAGE No 2-5 CURRENT TRANSFORMER MODEL J REV 8DEC00 TYPICAL EXCITATION CURVE for MODEL J at 60HZ 0 INDUCED VOLTAGE (volt) :5A 000:5A 200:5A 6000:5 4000:5 2500:5A 500:5A 0:5 500:5A EXCITING CURRENT (amp) NUMBER * J xxx J-0-00-xxx J xxx J xxx J xxx J xxx J xxx J xxx J xxx J xxx J xxx RATIO 500:5A 0:5A 200:5A 500:5A 2500:5A 000:5A 8000:5A 60HZ ± % BURDEN (VA) NOMINAL WINDING RESISTANCE (ohm) * "xxx" describes termination: "T" FOR BRASS SCREW TERMINALS and "Lyyy" FOR LEAD WIRES (Where "yyy" is the lead length in inches. For example, "L24" represents 24 inch long lead wires.)

5 CURRENT TRANSFORMER MODEL J5 -/2" x 4-/4" PAGE No 2-6 REV 8DEC BRASS SCREW TERMINAL (2 PLACES) Ø 4 (4 PLACES) H X NOTES:.)ALL DIMENSIONS IN INCHES 2.)ALL DIMENSIONS REF ONLY OPTIONAL MOUNTING PLATE BONDED TO TRANSFORMER Specifications Secondary sources 5 amps AC at rated F.S. primary current Nominal operating frequency range is HZ Thermal rating factor 0C for all ratios Insulation voltage class is 0.6KV BIL 0KV For indoor applications only Reference documents IEEE C57., UL244, CSA CAN-C-M8, and IEC 44- Enclosure is multi-layer tape buildup with heavy vinyl finish, color is black Optional plate is XX phenolic Options, contact Factory for information 2.0, 5.0, and 0 VAC output at F.S. primary amperage. Other non - standard ratings also available. Custom lead wire lengths and types A output at F.S. primary amperage. Other non-standard ratings also available Thermal ratings above. for selected ratios 8-2 Screw Terminals or #6 AWG UL 05 Lead Wires

6 -/2" x 4-/4" PAGE No 2-7 CURRENT TRANSFORMER MODEL J5 REV 8DEC00 0 TYPICAL EXCITATION CURVE FOR MODEL J5 at 60HZ 0 2 INDUCED VOLTAGE (volt) :5A 00:5A 000:5A 9000:5A EXCITING CURRENT (amp) NUMBER * RATIO 60HZ ± % BURDEN (VA) NOMINAL WINDING RESISTANCE (ohm) J xxx J xxx J xxx J xxx J xxx J xxx J xxx J xxx 000:5A 7000:5A 9000:5A 00:5A * "xxx" describes termination: "T" FOR BRASS SCREW TERMINALS and "Lyyy" FOR LEAD WIRES (Where "yyy" is the lead length in inches. For example, "L24" represents 24 inch long lead wires.)

7 CURRENT TRANSFORMER MODEL J6 " x 8-/4" PAGE No 2-8 REV 8DEC BRASS SCREW TERMINAL (2 PLACES) H X NOTES:.) ALL DIMENSIONS IN INCHES 2.) ALL DIMENSIONS REF ONLY OPTIONAL MOUNTING PLATE BONDED TO TRANSFORMER Ø 4 (4 PLACES) Specifications Secondary sources 5 amps AC at rated F.S. primary current Nominal operating frequency range is HZ Thermal rating factor 0C for all ratios Insulation voltage class is 0.6KV BIL 0KV For indoor applications only Reference documents IEEE C57., UL244, CSA CAN-C-M8, and IEC 44- Enclosure is multi-layer tape buildup with heavy vinyl finish, color is black Optional plate is XX phenolic Options, contact Factory for information 2.0, 5.0, and 0 VAC output at F.S. primary amperage. Other non - standard ratings also available. A output at F.S. primary amperage. Other non-standard ratings also available Thermal ratings above. for selected ratios 8-2 Screw Terminals or #6 AWG UL 05 Lead Wires Custom lead wire lengths and types

8 " x 8-/4" PAGE No 2-9 CURRENT TRANSFORMER MODEL J6 REV 8DEC00 0 TYPICAL EXCITATION CURVE FOR MODEL J6 at 60HZ INDUCED VOLTAGE (volt) :5A EXCITING CURRENT (amp) NUMBER * J xxx J xxx J xxx J xxx RATIO 8000:5A 60HZ ± % BURDEN (VA) NOMINAL WINDING RESISTANCE (ohm) * "xxx" describes termination: "T" FOR BRASS SCREW TERMINALS and "Lyyy" FOR LEAD WIRES (Where "yyy" is the lead length in inches. For example, "L24" represents 24 inch long lead wires.)

9 CURRENT TRANSFORMER MODEL J7/2 7" x 2" PAGE No 2-0 8DEC BRASS SCREW TERMINAL (2 PLACES) Ø 8 (4 PLACES) H X NOTES:.) ALL DIMENSIONS IN INCHES 2.) ALL DIMENSIONS REF ONLY OPTIONAL MOUNTING PLATE BONDED TO TRANSFORMER Specifications Secondary sources 5 amps AC at rated F.S. primary current Nominal operating frequency range is HZ Thermal rating factor 0C for all ratios Insulation voltage class is 0.6KV BIL 0KV For indoor applications only Reference documents IEEE C57., UL244, CSA CAN-C-M8, and IEC 44- Enclosure is multi-layer tape buildup with heavy vinyl finish, color is black Optional plate is XX phenolic Options, contact Factory for information 2.0, 5.0, and 0 VAC output at F.S. primary amperage. Other non - standard ratings also available. A output at F.S. primary amperage. Other non-standard ratings also available Thermal ratings above. for selected ratios 8-2 Screw Terminals or #6 AWG UL 05 Lead Wires Custom lead wire lengths and types

10 7" x 2" PAGE No 2- CURRENT TRANSFORMER MODEL J7/2 REV 8DEC00 0 TYPICAL EXCITATION CURVE FOR MODEL J7/2 at 60HZ INDUCED VOLTAGE (volt) :5A 0:5A 000:5A EXCITING CURRENT (amp) NUMBER * J7/ xxx J7/ xxx J7/ xxx J7/ xxx J7/ xxx J7/ xxx J7/ xxx J7/ xxx RATIO 0:5A 000:5A 8000:5A 60HZ ± % BURDEN (VA) 6 40 NOMINAL WINDING RESISTANCE (ohm) * "xxx" describes termination: "T" FOR BRASS SCREW TERMINALS and "Lyyy" FOR LEAD WIRES (Where "yyy" is the lead length in inches. For example, "L24" represents 24 inch long lead wires.)

11 CURRENT TRANSFORMER MODEL J7/25 7" x 25" PAGE No 2-2 REV 8DEC BRASS SCREW TERMINAL (2 PLACES) Ø 8 (4 PLACES) H X NOTES:.) ALL DIMENSIONS IN INCHES 2.) ALL DIMENSIONS REF ONLY OPTIONAL MOUNTING PLATE BONDED TO TRANSFORMER Specifications Secondary sources 5 amps AC at rated F.S. primary current Nominal operating frequency range is HZ Thermal rating factor 0C for all ratios Insulation voltage class is 0.6KV BIL 0KV For indoor applications only Reference documents IEEE C57., UL244, CSA CAN-C-M8, and IEC 44- Enclosure is multi-layer tape buildup with heavy vinyl finish, color is black Optional plate is XX phenolic Options, contact Factory for information 2.0, 5.0, and 0 VAC output at F.S. primary amperage. Other non - standard ratings also available., 0.2, and 0. A output at F.S. primary amperage. Other nonstandard ratings also available 8-2 Screw Terminals or #6 AWG UL 05 Lead Wires Custom lead wire lengths and types Thermal ratings above. for selected ratios.

12 7" x 25" PAGE No 2- CURRENT TRANSFORMER MODEL J7/25 REV 8DEC00 0 TYPICAL EXCITATION CURVE FOR MODEL J7/25 at 60HZ 0 2 INDUCED VOLTAGE (volt) :5A 600:5A 0:5A EXCITING CURRENT (amp) NUMBER * J7/ xxx J7/ xxx J7/ xxx J7/ xxx J7/ xxx RATIO 600:5A 2400:5A 60HZ ± % BURDEN (VA) NOMINAL WINDING RESISTANCE (ohm) * "xxx" describes termination: "T" FOR BRASS SCREW TERMINALS and "Lyyy" FOR LEAD WIRES (Where "yyy" is the lead length in inches. For example, "L24" represents 24 inch long lead wires.)

13 CURRENT TRANSFORMER MODEL J7/27 7" x 27" PAGE No 2-4 REV 8DEC BRASS SCREW TERMINAL (2 PLACES) Ø 8 (4 PLACES) H X NOTES:.) ALL DIMENSIONS IN INCHES 2.) ALL DIMENSIONS REF ONLY OPTIONAL MOUNTING PLATE BONDED TO TRANSFORMER Specifications Secondary sources 5 amps AC at rated F.S. primary current Nominal operating frequency range is HZ Thermal rating factor 0C for all ratios Insulation voltage class is 0.6KV BIL 0KV For indoor applications only Reference documents IEEE C57., UL244, CSA CAN-C-M8, and IEC 44- Enclosure is multi-layer tape buildup with heavy vinyl finish, color is black Optional plate is XX phenolic Options, contact Factory for information 2.0, 5.0, and 0 VAC output at F.S. primary amperage. Other non - standard ratings also available., 0.2, and 0. A output at F.S. primary amperage. Other nonstandard ratings also available 8-2 Screw Terminals or #6 AWG UL 05 Lead Wires Custom lead wire lengths and types Thermal ratings above. for selected ratios.

14 7" x 27" PAGE No 2-5 CURRENT TRANSFORMER MODEL J7/27 REV 8DEC00 0 TYPICAL EXCITATION CURVE FOR MODEL J7/27 at 60HZ 0 2 INDUCED VOLTAGE (volt) :5A EXCITING CURRENT (amp) NUMBER * J7/ xxx J7/ xxx J7/ xxx RATIO 2500:5A 60HZ ± % BURDEN (VA) 0 55 NOMINAL WINDING RESISTANCE (ohm) * "xxx" describes termination: "T" FOR BRASS SCREW TERMINALS and "Lyyy" FOR LEAD WIRES (Where "yyy" is the lead length in inches. For example, "L24" represents 24 inch long lead wires.)

15 CURRENT TRANSFORMER MODEL J0/24 0" x 24" PAGE No 2-6 REV 8DEC BRASS SCREW TERMINAL (2 PLACES) Ø 8 (4 PLACES) H X NOTES:.) ALL DIMENSIONS IN INCHES 2.) ALL DIMENSIONS REF ONLY OPTIONAL MOUNTING PLATE BONDED TO TRANSFORMER Specifications Secondary sources 5 amps AC at rated F.S. primary current Nominal operating frequency range is HZ Thermal rating factor 0C for all ratios Insulation voltage class is 0.6KV BIL 0KV For indoor applications only Reference documents IEEE C57., UL244, CSA CAN-C-M8, and IEC 44- Enclosure is multi-layer tape buildup with heavy vinyl finish, color is black Optional plate is XX phenolic Options, contact Factory for information 2.0, 5.0, and 0 VAC output at F.S. primary amperage. Other non - standard ratings also available., 0.2, and 0. A output at F.S. primary amperage. Other nonstandard ratings also available 8-2 Screw Terminals or #6 AWG UL 05 Lead Wires Custom lead wire lengths and types Thermal ratings above. for selected ratios.

16 0" x 24" PAGE No 2-7 CURRENT TRANSFORMER MODEL J0/24 REV 8DEC00 0 TYPICAL EXCITATION CURVE FOR MODEL J0/24 at 60HZ 0 2 INDUCED VOLTAGE (volt) :5A EXCITING CURRENT (amp) NUMBER * J0/ xxx J0/ xxx RATIO 000:5A 60HZ ± % BURDEN (VA) 0 85 NOMINAL WINDING RESISTANCE (ohm) * "xxx" describes termination: "T" FOR BRASS SCREW TERMINALS and "Lyyy" FOR LEAD WIRES (Where "yyy" is the lead length in inches. For example, "L24" represents 24 inch long lead wires.)

CURRENT TRANSFORMER MODEL 546 UL1015 #16 AWG LEAD WIRE, STANDARD LENGTH IS 24" 1 X

CURRENT TRANSFORMER MODEL 546 UL1015 #16 AWG LEAD WIRE, STANDARD LENGTH IS 24 1 X CURRENT TRANSFORMER MODEL 546 1.10" I.D. PAGE No 1-38 REV 15DEC00 TERMINAL OPTION LEAD WIRE OPTION 1.10 0 1.20 2.55 3.00 3.47 0.18 x 0.31 SLOT ( 2 PLACES) 8-32 BRASS STUD (2 PLACES) UL1015 #16 AWG LEAD

More information

0.84" x 2.00" Z-TRAUQ INC. Tel.: (450)226-6997 Fax: (450)226-5837 z-trauq@qc.aira.com SPLIT CORE CURRENT TRANSFORMER MODEL 1SP.

0.84 x 2.00 Z-TRAUQ INC. Tel.: (450)226-6997 Fax: (450)226-5837 z-trauq@qc.aira.com SPLIT CORE CURRENT TRANSFORMER MODEL 1SP. SPLIT CORE CURRENT MODEL 1SP 0.84" x 2.00" PAGE No 3-2 REV 18DEC00 UL 1015 LEAD WIRE, STANDARD LENGTH IS 36 E DIMENSIONS A = 0.84 MIN B = 2.00 MIN C = 3.31 MAX D = 3.09 MAX E = 0.61 MAX F = 0 MAX F C B

More information

Ω POWEROHM RESISTORS, INC. Braking Resistors for Variable Frequency Drives APPLICATION SELECTING A STANDARD DESIGN CUSTOM RATINGS

Ω POWEROHM RESISTORS, INC. Braking Resistors for Variable Frequency Drives APPLICATION SELECTING A STANDARD DESIGN CUSTOM RATINGS Braking Resistors for Variable Frequency Drives APPLICATION AC variable frequency drives are commonly used with a general purpose AC induction motor to form a reliable variable speed drive system. For

More information

4 Posiflow Proportional Solenoid Valves

4 Posiflow Proportional Solenoid Valves 4 Posiflow Solenoid Brass or Stainless Steel Bodies 1/4" to 1/2" NPT 2/2 Features Flow rates adjustable between 0% and 100% of rating Flow rate can also be regulated by a range of electrical inputs (sensors,

More information

PS4-24 OWNERS MANUAL 24 VAC 90 WATT WALL MOUNTED CCTV POWER SUPPLY

PS4-24 OWNERS MANUAL 24 VAC 90 WATT WALL MOUNTED CCTV POWER SUPPLY PS4-24 OWNERS MANUAL 24 VAC 90 WATT WALL MOUNTED CCTV POWER SUPPLY 7320 Ashcroft, Suite 104 Houston, Texas 77081 p: 713-772-1404 f: 713-772-7360 e: info@juicegoose.com www.juicegoose.com 06-06 CONGRATULATIONS

More information

LOW-VOLTAGE CURRENT TRANSFORMERS

LOW-VOLTAGE CURRENT TRANSFORMERS LOWVOLTAGE CURRENT TRANSFORMERS 5 A Power network meters ND0 and ND type. N4Z and N5Z Tel: (+48 68) 45 75 39; 45 75 305; 45 75 3; 45 75 368; email: export@lumel.com.pl ul. Słubicka 657 Zielona Góra CONTENTS

More information

8146/5 Series Breaker Panelboards

8146/5 Series Breaker Panelboards 8146/5 Series Breaker Panelboards DISTRIBUTION BREAKER PANELBOARDS FOR HAZARDOUS & CORROSIVE ENVIRONMENTS Breaker Panels Features: Wide variety of Flameproof branch circuit breakers for Zone 1 & Division

More information

2a. IEM Indoor Metal Clad Medium Voltage Switchgear 15KV 16346-1. 2a. Section 16346 INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std.

2a. IEM Indoor Metal Clad Medium Voltage Switchgear 15KV 16346-1. 2a. Section 16346 INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std. 2a. IEM Indoor Metal Clad Medium Voltage Switchgear 15KV 16346-1 2a. Section 16346 INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std. Relays) Part 1 General 1.1 CONDITIONS AND REQUIREMENTS: A. Refer to

More information

Solid State Timers Type F

Solid State Timers Type F Solid State Timers Type F Class 9050 CATALOG CONTENTS Description.....................................................Page Product Descriptions............................................. 3 Application

More information

Digital Energy ITI. Instrument Transformer Basic Technical Information and Application

Digital Energy ITI. Instrument Transformer Basic Technical Information and Application g Digital Energy ITI Instrument Transformer Basic Technical Information and Application Table of Contents DEFINITIONS AND FUNCTIONS CONSTRUCTION FEATURES MAGNETIC CIRCUITS RATING AND RATIO CURRENT TRANSFORMER

More information

Tips for connecting 24-volt power

Tips for connecting 24-volt power Digital Designer s Guide Application NoteAN0604D Revision B Tips for connecting 24-volt power This application note covers choosing a transformer and connecting 24 volt AC power to a KMC Controls DDC controller.

More information

keep your measure under control

keep your measure under control INSTRUMENTACIÓN INDUSTRIAL ZURC, S.A. keep your measure under control CURRENT For measuring instruments. Mounted in selfexinguishing, plastic, strengthened cases. Isolation voltage V Made as per UNEEN

More information

AZ420 MINIATURE GENERAL PURPOSE RELAY

AZ420 MINIATURE GENERAL PURPOSE RELAY MINIATURE GENERAL PURPOSE RELAY FEATURES Rugged construction for high reliability Life expectancy greater than 0 million operations DC coils to 11 V Power consumption as low as 2 mw per pole available

More information

RM4TG20 three-phase network control relay RM4-T - range 200..500 V

RM4TG20 three-phase network control relay RM4-T - range 200..500 V Characteristics three-phase network control relay RM4-T - range 200..500 V Complementary [Us] rated supply voltage Output contacts Setting accuracy of time delay Delay at power up Measuring cycle Marking

More information

www.jameco.com 1-800-831-4242

www.jameco.com 1-800-831-4242 Distributed by: www.jameco.com 1-800-831-4242 The content and copyrights of the attached material are the property of its owner. SPECIFICATION CUSTOMER: JAMES DATE: 04.08.23 MODEL NO: DBU090030 DESIGNED

More information

Safety technique. Emergency stop module BO 5988 safemaster

Safety technique. Emergency stop module BO 5988 safemaster Safety technique Emergency stop module BO 5988 safemaster 0221562 Function diagram Pushbutton on Mains or emergencystop () K1 According to EC Directive for machines 98/37/EG According to IEC/E 60204-1

More information

DS 600. A contact free flux gate based current measurement sensor 600A rms

DS 600. A contact free flux gate based current measurement sensor 600A rms DS 600 A contact free flux gate based current measurement sensor 600A rms DS 600 is member of the small housing sensor family. The family includes a 200A and a 600A version. 600A rms - 900A peak Maximum

More information

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2... Magnetic and Hydraulic-Magnetic Circuit Breaker 840-G2... Description Single, two and three pole magnetic circuit breakers with trip-free mechanism and push/pull on/off manual actuation. A choice of fast

More information

Voltage Regulator SPAU 341 C. Product Guide

Voltage Regulator SPAU 341 C. Product Guide Issued: July 1998 Status: Updated Version: D/25.04.2006 Data subject to change without notice Features Comprehensive voltage regulation for power transformers with on-load tapchangers in distribution substations

More information

AMFA-27 AMFA-29. Operator s Manual & Installation Instructions. Rev. 2.5

AMFA-27 AMFA-29. Operator s Manual & Installation Instructions. Rev. 2.5 AMFA-27 AMFA-29 Operator s Manual & Installation Instructions Rev. 2.5 Date: 17 July, 2010 Permanently-connected, utility Interactive, single-phase, inverters Model AMFA-27 WIND TURBINE INVERTER (240 VAC

More information

HPS Universal. Single and Three Phase Potted. Buck-Boost Transformers. Buck-Boost Applications & Standard Specification... 80

HPS Universal. Single and Three Phase Potted. Buck-Boost Transformers. Buck-Boost Applications & Standard Specification... 80 Buck-Boost Transformers Single and Three Phase Potted Buck-Boost Transformers Buck-Boost Applications & Standard Specification... 80 Selecting Buck-Boost Transformers... 81 Single Phase Selection Tables...

More information

Vario-Series Accessories

Vario-Series Accessories Accessories and spare parts for GMW analogue panel meters and controllers Current Transformers pages 2-9 Shunt Resistors 10-11 Voltage Dividers 12 Power supply for indicator/controllers 13 Blanking Plates

More information

Tape Wound, Split Core and Ebony Current Transformers

Tape Wound, Split Core and Ebony Current Transformers Tape Wound, Split Core and Ebony Current Transformers Current Transformers Contents Page Tape Wound Measuring and Protection Current Transformers 2 6 Split Core Current Transformers 7 9 3-in-1 Current

More information

Centro-Matic Automatic Lubrication Systems System Controls

Centro-Matic Automatic Lubrication Systems System Controls Selecting the right controls for your automated lubrication system is one of the last steps in the design process. Several different models may be chosen to control power-operated pumps, depending on the

More information

SAFETY PRECAUTIONS AND INSTRUCTIONS FOR USE OF TECHNICAL INFORMATION

SAFETY PRECAUTIONS AND INSTRUCTIONS FOR USE OF TECHNICAL INFORMATION SAFETY PRECAUTIONS AND INSTRUCTIONS FOR USE OF TECHNICAL INFORMATION Please read and understand the product instruction manual before installing, servicing or operating Yaskawa products. Technical content

More information

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application 33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application Features Compliant with the IEEE802.3at Standard -40 to +60 C Temperature Range Diagnostic LEDs Full Protection

More information

Distribution Dry Type Transformers

Distribution Dry Type Transformers 8 TRASFORMERS Distribution Dry Type Transformers Table (Contact Sales office for List Price) (commonly used) 1a. 115 C Rise F 1b. 80 C Rise B 4. Wall Brackets1 W 6. Low noise XdB below std. LX Type bg

More information

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous Safety relay for monitoring E-STOP pushbuttons. Approvals Unit features Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous 1 auxiliary contact (N/C), instantaneous Safe separation of

More information

12V Dimmable Driver EL-TMDRVR

12V Dimmable Driver EL-TMDRVR Elemental LED, LLC website: elementalled.com 11 9 5 P a r k A v e., S u i t e 2 11 Emeryville, CA 94608 toll free 877.564.5051 fax 510.740.4457 12V Dimmable Driver EL-TMDRVR ETL Listed #4001928 CSA Listed

More information

Product Guide AC Voltage Control Devices. Guide Guide. Popular Variable Transformers and AC Power Supplies. www.stacoenergy.com

Product Guide AC Voltage Control Devices. Guide Guide. Popular Variable Transformers and AC Power Supplies. www.stacoenergy.com Popular Variable Transformers and AC Power Supplies Product Guide AC Voltage Control Devices Guide Guide Your Tailored Power Solutions Provider TM Staco Energy Products Co. has been a leading manufacturer

More information

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features: Application : RISH Master 3490 DS measures important electrical parameters of Utility (in normal mode) & Generators (in Power back up) in three phase and single phase Network & replaces the multiple analog

More information

Temperature sensor with integrated transmitter for industrial applications, MBT 3560

Temperature sensor with integrated transmitter for industrial applications, MBT 3560 Temperature sensor with integrated transmitter for industrial applications, MBT 3560 Technical brochure Features Designed for use in harsh industrial enviroments where reliable, robust and accurate equipment

More information

RM17TE 183...528 V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

RM17TE 183...528 V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC Characteristics multifunction control relay RM17-TE - range 183..528 V AC Complementary Reset time Maximum switching voltage Minimum switching current Maximum switching current [Us] rated supply voltage

More information

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points Features SELV Compliant No Detection Passive Injector Gigabit Compatible Full Protection

More information

SECTION 26 09 13 - POWER MONITOR FOR ELECTRICAL, STEAM CONDENSATE, AND WATER PART I - GENERAL

SECTION 26 09 13 - POWER MONITOR FOR ELECTRICAL, STEAM CONDENSATE, AND WATER PART I - GENERAL SECTION 26 09 13 - POWER MONITOR FOR ELECTRICAL, STEAM CONDENSATE, AND WATER PART I - GENERAL 1.1 SUMMARY A. This section describes the requirements for the installation of Power Monitors and associated

More information

FW-X240 AUTO TRANSFORMER Installation Manual

FW-X240 AUTO TRANSFORMER Installation Manual FW-X240 AUTO TRANSFORMER Installation Manual 1 FW-X240 Auto Transformer About OutBack Power Systems OutBack Power Systems is a leader in advanced energy conversion technology. Our products include true

More information

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features Central 48 V DC Power Supplies for PoE-Components MICROSENS Description Active network equipment which is supporting the Power-over-Ethernet functions, typically requires a powerful 48 V DC power supply.

More information

Lightning Arresters P30027 18 KVA P30038 10 KVA. Description & Installation

Lightning Arresters P30027 18 KVA P30038 10 KVA. Description & Installation Lightning Arresters P30027 18 KVA P30038 10 KVA Description & Installation Printed in USA 09/11 TO330 Rev. B Table of Contents Page 1.0 SCOPE 2 2.0 PRODUCT OVERVIEW 2 2.1 Intended Uses 2 2.2 Lightning

More information

Type: EASY719 DC RC Article No.: 274119. Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

Type: EASY719 DC RC Article No.: 274119. Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description Type: EASY719 DC RC Article.: 274119 Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC Description 12 digital inputs (4 inputs available as analog inputs) 6 relay outputs LCD display

More information

SX460. Generator Automatic Voltage Regulator Operation Manual

SX460. Generator Automatic Voltage Regulator Operation Manual SX460 Generator Automatic Voltage Regulator Operation Manual Self Excited Automatic Voltage Regulator Compatible with Newage SX460* * Use for reference purpose only and not a genuine Newage product. 1.

More information

Current Transformers. Bonneville Power Administration. Steve Laslo For the Hands On Relay School (3-12) Revision 1.1. February 21, 2012 1

Current Transformers. Bonneville Power Administration. Steve Laslo For the Hands On Relay School (3-12) Revision 1.1. February 21, 2012 1 Current Transformers Bonneville Power Administration Steve Laslo For the Hands On Relay School (3-12) Revision 1.1 February 21, 2012 1 Basic Theory: CT as a Voltage Transformer February 21, 2012 2 CT as

More information

Industrial Control Power Transformers

Industrial Control Power Transformers Class MT Features Epoxy-encapsulated (50 5000); Completely seals the transformer coils against moisture, dust, dirt and industrial contaminants for maximum protection in hostile and industrial environments

More information

T 3000. Substation Maintenance and Commissioning Test Equipment

T 3000. Substation Maintenance and Commissioning Test Equipment T 3000 Substation Maintenance and Commissioning Test Equipment Multi function system for testing substation equipment such as: current, voltage and power transformers, all type of protection relays, energy

More information

FEATURES BODY DIA. MAX. Type M AWG 30: 0.0100 [0.254] Type C AWG 28: 0.0126 [0.320] Type T AWG 30: 0.0100 [0.254]

FEATURES BODY DIA. MAX. Type M AWG 30: 0.0100 [0.254] Type C AWG 28: 0.0126 [0.320] Type T AWG 30: 0.0100 [0.254] M, C, T NTC Thermistors, Coated FEATURES Small size - conformally coated. Wide resistance range. Available in 11 different R-T curves. DESCRIPTION Models M, C, and T are conformally coated, leaded thermistors

More information

Current transformers (CT) & Shunts

Current transformers (CT) & Shunts Current transformers (CT) & Shunts Genreal overview LV CURRENT TRANSFORMERS Product selection guide Standard industrial transformers?????? TCR - TCRO range NEW 9 9 9 Current summation JVM 0 9 TCR usbar

More information

Panel Meters and Controllers Modular Panel Meter Type EDM 35

Panel Meters and Controllers Modular Panel Meter Type EDM 35 Panel Meters and Controllers Modular Panel Meter Type EDM 35 Modular digital panel meter, 3 1/2-digit Indicating or controlling current, voltage, resistance, temperature, tacho or frequency. Easy programming

More information

LOW VOLTAGE RING TYPE MEASURING CURRENT TRANSFORMERS

LOW VOLTAGE RING TYPE MEASURING CURRENT TRANSFORMERS Specification for LOW VOLTAGE RING TYPE MEASURING CURRENT TRANSFORMERS CEYLON ELECTRICITY BOARD SRI LANKA Specification for LOW VOLTAGE RING TYPE MEASURING CURRENT TRANSFORMERS CEB Standard 027: 1998 CEYLON

More information

Selecting Current Transformers Part 1 By Darrell G. Broussard, P.E.

Selecting Current Transformers Part 1 By Darrell G. Broussard, P.E. By Darrell G. Broussard, P.E. Introduction: As engineers, we are aware that electrical power systems have grown. How much have they grown? When was the last time you specified a 2400-volt system, a 4160-volt

More information

5 Non-Ventilated Automation Transformers

5 Non-Ventilated Automation Transformers 5 Non-Ventilated Automation Transformers Automation Transformers - Non-Ventilated 50 VA to 45 SolaHD encapsulated transformers are rated for Hazardous Locations as well as harsh industrial environments.

More information

08. SEK IDC CONNECTORS

08. SEK IDC CONNECTORS . IDC CONNECTORS connectors for flat cables enable simple and, cost-optimized device configuration. connectors are preferably used for connection within the device. HARTING offers a broad range of these

More information

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592. * see variants. Applications.

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592. * see variants. Applications. Safety Technique SAFEMASTER Emergency Stop Module BG 5924, IP 5924 Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592 BG 5924 IP 5924 Product Description

More information

Tape Wound, Split Core and Ebony Current Transformers

Tape Wound, Split Core and Ebony Current Transformers Tape Wound, Split Core and Ebony Current Transformers Table of contents Tape Wound Measuring and Protection Current Transformers 2 MR Series Measuring Range 3 PR Series Protection Range 4 Class PX Current

More information

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER Application : The RISH CON - Hz transducer is used for frequency measurement. The output signal is proportional to measured frequency and is either load independent DC Current or load independent DC Voltage.

More information

AC Line Rated Ceramic Disc Capacitors Class X1, 760 V AC / Class Y1, 500 V AC

AC Line Rated Ceramic Disc Capacitors Class X1, 760 V AC / Class Y1, 500 V AC 4L Series AC Line Rated Ceramic Disc Capacitors Class X, 76 V AC / Class Y, 5 V AC FEATURES Complies with IEC 6384-4, 4 th edition High reliability Radial leads High capacitance up to nf Singlelayer AC

More information

VSO MAX HP High Flow Proportional Valve

VSO MAX HP High Flow Proportional Valve VSO MAX HP High Flow Proportional Valve Typical Applications Ventilators Insufflators Anesthesia Delivery & Monitors Pressure & Flow Control Mass Flow Control Product Specifications Physical Properties

More information

READ THIS MANUAL BEFORE PROCEEDING WITH THE INSTALLATION. FAILURE TO FOLLOW THE INSTALLATION INSTRUCTIONS MAY VOID YOUR WARRANTY!

READ THIS MANUAL BEFORE PROCEEDING WITH THE INSTALLATION. FAILURE TO FOLLOW THE INSTALLATION INSTRUCTIONS MAY VOID YOUR WARRANTY! READ THIS MANUAL BEFORE PROCEEDING WITH THE INSTALLATION. FAILURE TO FOLLOW THE INSTALLATION INSTRUCTIONS MAY VOID YOUR WARRANTY! The main power to any existing system must be disconnected prior to the

More information

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application. 1SR 430 824 F9300 Features Monitoring of three-phase mains for phase sequence and failure Powered by the measuring circuit 2 c/o (SPDT) contacts 1 LED for status indication Approvals R: yellow LED - relay

More information

Reyrolle Protection Devices. 7PG17 - XR Intertripping, Interposing, Supervision and Special Purpose Relays. Answers for energy

Reyrolle Protection Devices. 7PG17 - XR Intertripping, Interposing, Supervision and Special Purpose Relays. Answers for energy Reyrolle Protection Devices 7PG17 - XR Intertripping, Interposing, Supervision and Special Purpose Relays. Answers for energy Siemens Protection Devices Limited 2 7PG17 XR101 & XR102 Intertripping Relay

More information

Analog signal converters CC-E I/I Current / current isolators

Analog signal converters CC-E I/I Current / current isolators ata sheet Analog signal converters CC-E I/I Current / current isolators The CC-E I/I is an isolator for the electrical isolation of current signals without auxiliary supply. It allows the isolation between

More information

Directory chapter 04

Directory chapter 04 M Directory chapter 04 D-Sub Mixed subminiature D connectors New Page D-Sub mixed connector system general information................... 04.02 Contact arrangements............................................

More information

5 Non-Ventilated Automation Transformers

5 Non-Ventilated Automation Transformers 5 Non-Ventilated Automation Transformers Automation Transformers - Non-Ventilated 50 VA to 45 SolaHD encapsulated transformers are rated for Hazardous Locations as well as harsh industrial environments.

More information

KOLMA and IHDA Indoor type Cable Current Transformers Catalogue ABB Power Distribution ABB Transmit 1 KKOLMA 1 GB

KOLMA and IHDA Indoor type Cable Current Transformers Catalogue ABB Power Distribution ABB Transmit 1 KKOLMA 1 GB KOLMA and IHDA Indoor type Cable Current Transformers Catalogue ABB Power Distribution ABB Transmit 1 KKOLMA 1 GB KOLMA and IHDA Indoor Type Cable Current Transformers Index Description... 3 Technical

More information

mpm DIN 43650 CONNECTORS

mpm DIN 43650 CONNECTORS mpm DIN 43650 CONNECTORS : Highest quality, robust connectors for hydraulic and pneumatic electromechanical devices Broad offering of DIN 43650 connectors and devices Combined Brad and mpm cordsets : Provide

More information

SKP Series SKP15U.. Gas Valve Actuator with Safety Shutoff Function

SKP Series SKP15U.. Gas Valve Actuator with Safety Shutoff Function SKP Series SKP15U.. Gas Valve Actuator with Safety Shutoff Function Document No. 155-751 SKP15U.. Description Only when assembled to Series VGU Gas valves SKP15 electro-hydraulic actuators combine with

More information

Problem / Solution. The problem:

Problem / Solution. The problem: Problem / Solution Solar Photovoltaic (PV) technology has shown significant development in recent years and this has led to many UK homeowners investing in Solar PV installations. Solar electricity is

More information

Current Transformers

Current Transformers Tyco Electronics Corporation Crompton Instruments 1610 Cobb International Parkway, Unit #4 Kennesaw, GA 30152 Tel. 770-425-8903 Fax. 770-423-7194 Current Transformers Current transformers (CT's) provide

More information

713 Open Channel Flowmeter and Transmitter. All-in-one package for open channel flow measurement.

713 Open Channel Flowmeter and Transmitter. All-in-one package for open channel flow measurement. and Transmitter All-in-one package for open channel flow measurement. 3.1 NEW Class 1, Division 1 Approved Sensor As our products are continuously improved, we reserve the right to make any change in the

More information

12S, 14S, 15S Series. Time Delay Relays and Sequencers. Time Delay Relays and Sequencers. Features and Benefits. Switch Actions and Configurations

12S, 14S, 15S Series. Time Delay Relays and Sequencers. Time Delay Relays and Sequencers. Features and Benefits. Switch Actions and Configurations 12S, 14S, 15S Series Time Delay Relays and Sequencers Time Delay Relays and Sequencers The Therm-O-Disc type 12S, 14S and 15S series time delay relays and sequencers are field-proven devices for controlling

More information

Intersection Preassembled 19-inch Rack

Intersection Preassembled 19-inch Rack Intersection Preassembled 19-inch Rack The intersection preassembled 19-inch rack comes fully assembled, wired and ready to be installed in a server rack. The rack provides communications, power conversion

More information

38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A

38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A 38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit EMR Electromechanical Relays

More information

Low Voltage Transformers Sealed, General Purpose, Dry Type

Low Voltage Transformers Sealed, General Purpose, Dry Type Low Voltage Transformers Sealed, General Purpose, Dry Type Catalog 7400CT9601R4/08 08 Class 7400 CONTENTS Description..............................................Page Introduction.................................................

More information

Thermistor motor protection

Thermistor motor protection Thermistor motor protection CM-E Range Thermistor motor protection Thermistor motor protection relays Benefits and advantages Selection table Operating principle and fields of application for thermistor

More information

RC NETWORKS SALES GUIDE

RC NETWORKS SALES GUIDE SALES GUIDE INTRODUCTION TO Recent developments in electronic equipment have shown the following trends: Increasing demands for numerical control machines, robotics and technically advanced appliances

More information

Positronic Provides Complete Capability

Positronic Provides Complete Capability Catalog C-017 Rev H Experience Founded in 1966 Involvement in the development of international connector specifications through EIA, IEC and ISO as well as PICMG. Introduction of new and unique connector

More information

100% EMI Emission Containment

100% EMI Emission Containment 100% EMI Emission Containment Designed for Longer Service Life Highly Flexible for Easier Handling and Faster Installation Authorized Distributor Industrial VFD Cables Index n Variable Frequency Drive

More information

Measurement devices Accessories for analogue and digital instruments

Measurement devices Accessories for analogue and digital instruments Accessories for analogue and digital instruments 1 2CSC96F0001 Current transformers Used to transform primary currents (max. 6000 A) into.../5 A and.../1 A low secondary currents indirectly supplying power

More information

3/2-way Solenoid Valve, direct-acting, NC or NO

3/2-way Solenoid Valve, direct-acting, NC or NO 3/2-way Solenoid Valve, direct-acting, NC or NO Electrical connection cable plug, Form A With or without manual override as standard Threaded port and sub-base s Impulse optional Type 6014 can be combined

More information

Vert-X 16-5V / 10...90% Ub. Applications Servodrives Dancer arm Operating table

Vert-X 16-5V / 10...90% Ub. Applications Servodrives Dancer arm Operating table Version MH-C MH-C2 Electrical data Measuring range 0... 360 - Indep. linearity % meas. range ±0.3 - Max. hysteresis 0.1 - Resolution bit 12 - Max. repeatability 0.1 - Sample rate fast mode khz (5) - Sample

More information

Kuhlman Electric Corporation. 25000 Volt Instrument Transformers

Kuhlman Electric Corporation. 25000 Volt Instrument Transformers Kuhlman Electric Corporation 25000 Volt Instrument Transformers 25000 Volt Table of Contents Description Model Page Wound, Dry-Type VT Y Burden (High Accuracy available) PTT-150-9710(H) 3-4 Wound, Oil-Filled

More information

Top Microsystems Proprietary Specification P/N: W090015HK-XP 022410RB-082709V.A0 SPECIFICATION

Top Microsystems Proprietary Specification P/N: W090015HK-XP 022410RB-082709V.A0 SPECIFICATION SPECIFICATION High Quality Switching Wallmount Adapter Interchangeable AC Plugs 90-264VAC Input 13.5W 9VDC 1.5A Output P/N: W090015HK-XP ** Specification Approval** This specification (total 11 pages including

More information

Series AMEPR30-AZ up to 2.5A AC-DC / DC-DC LED Driver / Converter

Series AMEPR30-AZ up to 2.5A AC-DC / DC-DC LED Driver / Converter FEATURES: Click on Series name for product info on aimtec.com Models Single output Model Max Output Power (W) 1 AC-DC Constant Current or Constant Over temperature protection Voltage LED Driver Over current

More information

Submit shop drawings for equipment provided under this section Shop drawings shall indicate:

Submit shop drawings for equipment provided under this section Shop drawings shall indicate: Section 16435 - SWITCHBOARDS Introduction Part 1 - General Reference The work under this section is subject to requirements of the Contract Documents including the General Conditions, Supplementary Conditions,

More information

Pow-R-Con Multi Function Control

Pow-R-Con Multi Function Control 37264 Pow-R-Con Multi Function Control Product Specification Product Specification 37264 Product Information DYNA Power Controls Pow-R-Con TM GENERAL The Barber-Colman Pow-R-Con TM represents an integrated

More information

Custom Products. Magnetic Components. Vishay Dale. www.vishay.com

Custom Products. Magnetic Components. Vishay Dale. www.vishay.com Magnetic Components SWITCH MODE MAGNETICS AIR CORE INDUCTORS INDUCTIVE PRODUCTS CUSTOM DESIGN AND PRODUCTION has extensive facilities for custom design and production of custom magnetics. Design applications

More information

38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A

38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A 38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A 38 SERIES Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit EMR Electromechanical

More information

1SMB59xxBT3G Series, SZ1SMB59xxT3G Series. 3 Watt Plastic Surface Mount Zener Voltage Regulators

1SMB59xxBT3G Series, SZ1SMB59xxT3G Series. 3 Watt Plastic Surface Mount Zener Voltage Regulators 9xxBTG Series, SZ9xxTG Series Watt Plastic Surface Mount Zener Voltage Regulators This complete new line of W Zener diodes offers the following advantages. Features Zener Voltage Range. V to V ESD Rating

More information

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description Photoelectrics, Background Suppression reflective with IR light Main features Description The PD30ET... stainless steel sensors are built with high-quality materials and designed for harsh environments.

More information

Relays and Timers Specifications Bulletin Number 700

Relays and Timers Specifications Bulletin Number 700 Technical Data Relays and Timers Specifications Bulletin Number 700 Topic Page General Purpose Relays 2 Timing Relays 41 NEMA Industrial Relays 81 IEC Control Relays 93 Solid State Relays 109 Additional

More information

Medium voltage product. Instrument transformers for indoor applications Product overview

Medium voltage product. Instrument transformers for indoor applications Product overview Medium voltage product Instrument transformers for indoor applications Product overview 02 Contents Introduction Current transformers Supporting type 6 TPU, TPE 7 KOFA, IHBF 10 Dummy Bus type 8 KOKS 12,

More information

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages Data sheet Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages The CM-ESS.2 is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of

More information

Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument 4921210109D

Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument 4921210109D 7000/7000C/7020 Multi-instrument 4921210109D Features Measurements All 3-phase AC measurements True RMS Replaces analogue meters Demand on each phase current Accuracy U, I and F class 0.5 Other values

More information

Voltage Loss Formula s

Voltage Loss Formula s www.litz-wire.com HM Wire International Inc. Phone: 330-244-8501 Fax: 330-244-8561 Voltage Loss Formula s www.hmwire.com Voltage loss in a wire is synonymous to pressure loss in a pipe. Electric current

More information

Generator DoCKInG StatIonS

Generator DoCKInG StatIonS Generator DOCKING STATIONS TRYSTAR Portable Power Cable Cam to cam cable extensions 2000V, 100A-400A rated to NEC table 400.5 (B) All portable power cable sold is highly flexible and UL & C-UL or CSA Listed

More information

VLT Series 3500 Adjustable Frequency Drive Instruction Manual

VLT Series 3500 Adjustable Frequency Drive Instruction Manual Adjustable Frequency Drive Instruction Manual VLT Series 3500 Instruction Manual 175R5237 - Document Version 5.00 This manual applies to all VLT Series 3502-3800 Adjustable Frequency Drives with software

More information

Circuit Breakers. NRC Series. NRC Series. 900 www.idec.com

Circuit Breakers. NRC Series. NRC Series. 900 www.idec.com Switches & Pilot Lights Display Lights NRC series circuit breakers offer circuit protection which is far superior to using fuses in applications containing relay circuits, motor circuits, heater circuits,

More information

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter Thermal Mass meter and Temperature Transmitter Description The MTI10 insertion thermal mass flowmeter and the MTL10 in-line thermal mass flowmeter provide accurate mass flow measurement of clean, dry gases

More information

Enhanced Quality with a Touch of Style

Enhanced Quality with a Touch of Style Rudolf Current Transformer Enhanced Quality with a Touch of Style Current Transformer Enhanced Quality with a Touch of Style New Products Rudolf launched our new encapsulated current transformer. Portraying

More information

Three-phase monitoring relay CM-PFE

Three-phase monitoring relay CM-PFE Data sheet Three-phase monitoring relay CM-PFE The CM-PFE is a three-phase monitoring relay that monitors the phase parameter phase sequence and phase failure in three-phase mains. 2CDC 251 005 S0012 Characteristics

More information

H/L = Power supply. FN = Nominal Frequency. RN = Rated value of output burden. UN = Nominal input voltage. IN = Nominal input current.

H/L = Power supply. FN = Nominal Frequency. RN = Rated value of output burden. UN = Nominal input voltage. IN = Nominal input current. Application : The transducer RISH CON - CA/CV (Fig.1) converts a sinusoidal AC Current or AC Voltage into a load independent DC Current or a load independent DC Voltage proportional to the measured value.

More information

Signaling Lights. LH Series Surface Mount Indicators. Part Numbers. Jumbo Dome (one color) Jumbo Dome (two color)

Signaling Lights. LH Series Surface Mount Indicators. Part Numbers. Jumbo Dome (one color) Jumbo Dome (two color) Innovative indicators in a slim & stylish design. uces installation space. LH Series Surface Mount Indicators Key features of the LH series include: Direct mounting on surfaces such as panels, aluminum