1 Accessories for analogue and digital instruments 1 2CSC96F0001 Current transformers Used to transform primary currents (max A) into.../5 A and.../1 A low secondary currents indirectly supplying power to analogue and digital measurement devices. They are available both with wound and through primary. In the first case they are provided along with the bar or the primary terminal; in the second case they have a hole to insert in the bar or the cable which forms the primary. Standard type current transformers Code Type Code Type Description Current transformer with wound primary, primary and secondary current on terminals - - EQ 36 8 CTA/1-1 Iprim 1 A, 0.5 rating 5 VA, rating 1 7 VA EH CTA/5 EQ 37 6 CTA/5-1 Iprim 5 A, 0.5 rating 5 VA, rating 1 7 VA EH CTA/10 EQ 38 CTA/10-1 Iprim 10 A, 0.5 rating 5 VA, rating 1 7 VA EH CTA/15 EQ 39 2 CTA/15-1 Iprim 15 A, 0.5 rating 5 VA, rating 1 7 VA EH CTA/20 EQ CTA/20-1 Iprim 20 A, 0.5 rating 5 VA, rating 1 7 VA EH CTA/25 EQ CTA/25-1 Iprim 25 A, 0.5 rating 5 VA, rating 1 7 VA EH CTA/0 EQ 353 CTA/0-1 Iprim 0 A, 0.5 rating 5 VA, rating 1 7 VA EH 02 1 CTA/ EQ 35 2 CTA/-1 Iprim A, 0.5 rating 5 VA, rating 1 7 VA EH CTA/60 EQ CTA/60-1 Iprim 60 A, 0.5 rating 5 VA, rating 1 7 VA EH CTA/80 EQ CTA/80-1 Iprim 80 A, 0.5 rating 5 VA, rating 1 7 VA EH 027 CTA/100 EQ CTA/100-1 Iprim 100 A, 0.5 rating 5 VA, rating 1 7 VA Technical characteristics Standard secondary current [A] 5 (other secondary on request) Max. voltage for operation 1 [kv] 1.2 (0.72 for compact version) Test voltage 2 [kv] 6 at Hz/1 min. (3 for compact version) Short circuit rated thermal current I min 3 [IpN] 0 for 1 sec. Short circuit rated dynamic current I min [I ter ] 2.5 for 1 sec. Permanent overload [IpN] 1.2 Safety factor 5 [Fs] 2 at 10 according to version and capacity Frequency [Hx] /60 Air insulation Terminals 6 Housing Protection degree E class primary = P1, P2 (K-L) secondary = s1, s2 (k-l) P1 (K)=primary wound input P2 (L)=primary wound output s1 (k)=secondary wound input s2 (l)=secondary wound output with double ration on secondary s1-s2=lower ratio, s1-s3=higher ratio ABS resin IP30 Operating temperature [ C] Max. temperature on bars [ C] +70 Storage temperature [ C] Relative humidity 80% 1 Max. voltage (effective value) the transformer can bear. 2 Industrial frequency voltage in relation to insulation the transformer bears for 1 min. between the primary and the secondary. 3 Max. primary current (effective value) the transformer bears for 1 sec. with counter-circuited secondary without overload-induced damages. Max. primary current (effective value) the transformer bears for 1 sec. with counter-circuited secondary without damaged due to electromagnetic efforts. 5 Ratio between primary current causing nucleus saturation and the rated primary current value: the lower the Sf the higher the protection level on the transformer. 6 Brass terminals CuZn37, Mx6 screws with torsion value 1.9 Nm, tensile value 0 N/mm 2 and elasticity limit 30 N/mm 2. During the installation control the correct input (P1-K) and output (P2-L) direction of the primary cable. On versions with primary and secondary on terminals pay attention the connection of the primary with the secondary is not inverted. In the case of a detachment from measurement devices of the transformer in a connected plant counter-circuit the two terminals of the transformer. It is suggested to earth the transformers. 1/30 ABB SACE

2 Accessories for analogue and digital instruments Code Type Code Type Description - - EQ CTA1/1-1 Iprim 1 A, 0.5 rating 10 VA, rating 1 20 VA EH CTA1/5 EQ CTA1/5-1 Iprim 5 A, 0.5 rating 10 VA, rating 1 20 VA EH CTA1/10 EQ CTA1/10-1 Iprim 10 A, 0.5 rating 10 VA, rating 1 20 VA EH CTA1/15 EQ CTA1/15-1 Iprim 15 A, 0.5 rating 10 VA, rating 1 20 VA EH CTA1/20 EQ CTA1/20-1 Iprim 20 A, 0.5 rating 10 VA, rating 1 20 VA EH CTA1/25 EQ CTA1/25-1 Iprim 25 A, 0.5 rating 10 VA, rating 1 20 VA EH CTA1/0 EQ 36 1 CTA1/0-1 Iprim 0 A, 0.5 rating 10 VA, rating 1 20 VA EH CTA1/ EQ CTA1/-1 Iprim A, 0.5 rating 10 VA, rating 1 20 VA EH CTA1/60 EQ CTA1/60-1 Iprim 60 A, 0.5 rating 10 VA, rating 1 20 VA EH 00 7 CTA1/80 EQ 367 CTA1/80-1 Iprim 80 A, 0.5 rating 10 VA, rating 1 20 VA EH CTA1/100 EQ CTA1/100-1 Iprim 100 A, 0.5 rating 10 VA, rating 1 20 VA EH CTA1/1 EQ CTA1/1-1 Iprim 1 A, 0.5 rating 10 VA, rating 1 20 VA EH CTA1/200 EQ CTA1/200-1 Iprim 200 A, 0.5 rating 10 VA, rating 1 20 VA EH CTA1/2 EQ CTA1/2-1 Iprim 2 A, 0.5 rating 10 VA, rating 1 20 VA EH CTA1/300 EQ 372 CTA1/300-1 Iprim 300 A, 0.5 rating 10 VA, rating 1 20 VA EH CTA1/00 EQ CTA1/00-1 Iprim 00 A, 0.5 rating 10 VA, rating 1 20 VA EH 065 CTA1/0 EQ 37 0 CTA1/0-1 Iprim 0 A, 0.5 rating 10 VA, rating 1 20 VA EQ 3 7 CTA2/1-1 Iprim 1 A, 0.5 rating 10 VA, rating 1 35 VA EH CTA2/5 EQ CTA2/5-1 Iprim 5 A, 0.5 rating 10 VA, rating 1 35 VA EH CTA2/10 EQ CTA2/10-1 Iprim 10 A, 0.5 rating 10 VA, rating 1 35 VA EH CTA2/15 EQ CTA2/15-1 Iprim 15 A, 0.5 rating 10 VA, rating 1 35 VA EH CTA2/20 EQ CTA2/20-1 Iprim 20 A, 0.5 rating 10 VA, rating 1 35 VA EH 070 CTA2/25 EQ CTA2/25-1 Iprim 25 A, 0.5 rating 10 VA, rating 1 35 VA EH CTA2/0 EQ CTA2/0-1 Iprim 0 A, 0.5 rating 10 VA, rating 1 35 VA EH 07 6 CTA2/ EQ CTA2/-1 Iprim A, 0.5 rating 10 VA, rating 1 35 VA EH 0 3 CTA2/60 EQ CTA2/60-1 Iprim 60 A, 0.5 rating 10 VA, rating 1 35 VA EH CTA2/80 EQ 38 9 CTA2/80-1 Iprim 80 A, 0.5 rating 10 VA, rating 1 35 VA EH CTA2/100 EQ CTA2/100-1 Iprim 100 A, 0.5 rating 10 VA, rating 1 35 VA EH CTA2/1 EQ 386 CTA2/1-1 Iprim 1 A, 0.5 rating 10 VA, rating 1 35 VA EH 089 CTA2/200 EQ CTA2/200-1 Iprim 200 A, 0.5 rating 10 VA, rating 1 35 VA EH CTA2/2 EQ CTA2/2-1 Iprim 2 A, 0.5 rating 10 VA, rating 1 35 VA EH CTA2/300 EQ CTA2/300-1 Iprim 300 A, 0.5 rating 10 VA, rating 1 35 VA EH CTA2/00 EQ CTA2/00-1 Iprim 00 A, 0.5 rating 10 VA, rating 1 35 VA EH CTA2/0 EQ 391 CTA2/0-1 Iprim 0 A, 0.5 rating 10 VA, rating 1 35 VA 2CSC97F0001 EH CT3/0 EQ CT3/0-1 Iprim 0 A, 3 rating 2 VA EH CT3/ EQ CT3/-1 Iprim A, 3 rating 2 VA EH CT3/60 EQ 39 8 CT3/60-1 Iprim 60 A, 3 rating 2 VA EH CT3/80 EQ CT3/80-1 Iprim 80 A, 3 rating 3 VA EH CT3/100 EQ CT3/100-1 Iprim 100 A, 1 rating 3 VA EH CT3/1 EQ CT3/1-1 Iprim 1 A, 0.5 rating 3 VA EH CT3/200 EQ CT3/200-1 Iprim 200 A, 0.5 rating 3 VA EH CT3/2 EQ 00 3 CT3/2-1 Iprim 2 A, 0.5 rating 6 VA EH CT3/300 EQ 01 1 CT3/300-1 Iprim 300 A, 0.5 rating 6 VA EH 69 1 CT3/00 EQ 02 9 CT3/00-1 Iprim 00 A, 0.5 rating 6 VA EH CT3/0 EQ 03 7 CT3/0-1 Iprim 0 A, 0.5 rating 6 VA EH CT3/600 EQ 0 5 CT3/600-1 Iprim 600 A, 0.5 rating 6 VA 2CSC5105F0001 EH 697 CT/100 EQ 05 2 CT/100-1 Iprim 100 A, 1 rating 3 VA EH CT/1 EQ 06 0 CT/1-1 Iprim 1 A, 1 rating 3 VA EH CT/200 EQ 07 8 CT/200-1 Iprim 200 A, 0.5 rating VA EH CT/2 EQ 08 6 CT/2-1 Iprim 2 A, 0.5 rating 6 VA EH 701 CT/300 EQ 09 CT/300-1 Iprim 300 A, 0.5 rating 6 VA EH CT/00 EQ 11 0 CT/00-1 Iprim 00 A, 0.5 rating 10 VA EH CT/0 EQ 12 8 CT/0-1 Iprim 0 A, 0.5 rating 10 VA EH 70 8 CT/600 EQ 1 CT/600-1 Iprim 600 A, 0.5 rating 10 VA EH CT/800 EQ 15 1 CT/800-1 Iprim 800 A, 0.5 rating 10 VA EH CT/1000 EQ 16 9 CT/ Iprim 1000 A, 0.5 rating 10 VA ABB SACE 1/31

3 Accessories for analogue and digital instruments 1 2CSC98F0001 Code Type Code Type Description EH CT5/2 EQ 17 7 CT5/2-1 Iprim 2 A, 0.5 rating 3 VA EH CT5/300 EQ 18 5 CT5/300-1 Iprim 300 A, 0.5 rating VA EH CT5/00 EQ 19 3 CT5/00-1 Iprim 00 A, 0.5 rating 6 VA EH CT5/0 EQ 20 1 CT5/0-1 Iprim 0 A, 0.5 rating 10 VA EH CT5/600 EQ 9 CT5/600-1 Iprim 600 A, 0.5 rating 10 VA EH CT5/800 EQ 22 7 CT5/800-1 Iprim 800 A, 0.5 rating 10 VA EH CT5/1000 EQ 23 5 CT5/ Iprim 1000 A, 0.5 rating 10 VA EH 71 7 CT5/1200 EQ 2 3 CT5/ Iprim 1200 A, 0.5 rating 10 VA EH 715 CT5/10 EQ 25 0 CT5/10-1 Iprim 10 A, 0.5 rating 20 VA 2CSC5101F0001 2CSC510F0001 EH CT6/2 EQ 26 8 CT6/2-1 Iprim 2 A, 0.5 rating 5 VA EH CT6/300 EQ 27 6 CT6/300-1 Iprim 300 A, 0.5 rating 5 VA EH CT6/00 EQ 28 CT6/00-1 Iprim 00 A, 0.5 rating 6 VA EH CT6/0 EQ 29 2 CT6/0-1 Iprim 0 A, 0.5 rating 6 VA EH 720 CT6/600 EQ 30 0 CT6/600-1 Iprim 600 A, 0.5 rating 10 VA EH 7 2 CT6/800 EQ 31 8 CT6/800-1 Iprim 800 A, 0.5 rating 10 VA EH CT6/1000 EQ 32 6 CT6/ Iprim 1000 A, 0.5 rating 20 VA EH CT6/1200 EQ 33 CT6/ Iprim 1200 A, 0.5 rating 20 VA EH 72 6 CT6/10 EQ 3 2 CT6/10-1 Iprim 10 A, 0.5 rating 30 VA EH CT6/2000 EQ 35 9 CT6/ Iprim 2000 A, 0.5 rating 30 VA EH CT6/20 EQ 36 7 CT6/20-1 Iprim 20 A, 0.5 rating 30 VA EH CT8/300 EQ 37 5 CT8/300-1 Iprim 300 A, 0.5 rating 5 VA EH CT8/00 EQ 38 3 CT8/00-1 Iprim 00 A, 0.5 rating 6 VA EH CT8/0 EQ 39 1 CT8/0-1 Iprim 0 A, 0.5 rating 10 VA EH CT8/600 EQ 1 7 CT8/600-1 Iprim 600 A, 0.5 rating 10 VA EH CT8/800 EQ 2 5 CT8/800-1 Iprim 800 A, 0.5 rating 10 VA EH CT8/1000 EQ 3 3 CT8/ Iprim 1000 A, 0.5 rating 10 VA EH CT8/1200 EQ 1 CT8/ Iprim 1200 A, 0.5 rating 15 VA EH 73 5 CT8/10 EQ 5 8 CT8/10-1 Iprim 10 A, 0.5 rating 20 VA EH CT8/2000 EQ 6 6 CT8/ Iprim 2000 A, 0.5 rating 20 VA EH CT8/20 EQ 7 CT8/20-1 Iprim 20 A, 0.5 rating 20 VA EH CT8/3000 EQ 8 2 CT8/ Iprim 3000 A, 0.5 rating 20 VA EH 78 5 CT8-V/00 EQ 9 0 CT8-V/00-1 Iprim 00 A, 0.5 rating 6 VA EH 79 3 CT8-V/0 EQ 8 CT8-V/0-1 Iprim 0 A, 0.5 rating 10 VA EH 7 1 CT8-V/600 EQ 51 6 CT8-V/600-1 Iprim 600 A, 0.5 rating 10 VA EH 1 9 CT8-V/800 EQ 52 CT8-V/800-1 Iprim 800 A, 0.5 rating 10 VA EH 2 7 CT8-V/1000 EQ 53 2 CT8-V/ Iprim 1000 A, 0.5 rating 10 VA EH 3 5 CT8-V/1200 EQ 5 0 CT8-V/ Iprim 1200 A, 0.5 rating 10 VA EH 3 CT8-V/10 EQ 56 5 CT8-V/10-1 Iprim 10 A, 0.5 rating 10 VA EH 5 0 CT8-V/2000 EQ 57 3 CT8-V/ Iprim 2000 A, 0.5 rating 20 VA EH 6 8 CT8-V/20 EQ 58 1 CT8-V/20-1 Iprim 20 A, 0.5 rating 20 VA EH CT12/0 EQ 59 9 CT12/0-1 Iprim 0 A, 0.5 rating 10 VA EH 739 CT12/600 EQ 60 7 CT12/600-1 Iprim 600 A, 0.5 rating 10 VA EH 70 2 CT12/800 EQ 61 5 CT12/800-1 Iprim 800 A, 0.5 rating 15 VA EH 71 0 CT12/1000 EQ 63 1 CT12/ Iprim 1000 A, 0.5 rating 20 VA EH 72 8 CT12/1200 EQ 6 9 CT12/ Iprim 1200 A, 0.5 rating 20 VA EH 73 6 CT12/10 EQ 65 6 CT12/10-1 Iprim 10 A, 0.5 rating 20 VA EH 7 CT12/2000 EQ 66 CT12/ Iprim 2000 A, 0.5 rating 30 VA EH 1 CT12/20 EQ 67 2 CT12/20-1 Iprim 20 A, 0.5 rating 0 VA EH 76 9 CT12/3000 EQ 69 8 CT12/ Iprim 3000 A, 0.5 rating 0 VA EH 77 7 CT12/000 EQ 70 6 CT12/000-1 Iprim 000 A, 0.5 rating VA EH 88 8 CT12/00 EQ 71 CT12/00-1 Iprim 00 A, 0.5 rating VA EH CT12/6000 EQ 72 2 CT12/ Iprim 6000 A, 0.5 rating VA 1/32 ABB SACE

4 Standard type current transformers CTA From 1 to 0 A 5 from 0 to 100 A CTA1 TRFM modules CTA M M ø9 60 x35 ø Accessory for fixing on DIN rail ABB SACE /11

5 CT 109 CT5 5 1 CT , Accessory for fixing on DIN rail /12 ABB SACE

6 CT CT8-V ABB SACE /13

7 CT CT12-V /1 ABB SACE

CT Current transformers Ideal for measuring. Designed to create efficiency.

CT Current transformers Ideal for measuring. Designed to create efficiency. CT Current transformers Ideal for measuring. Designed to create efficiency. CT Current transformers Optimize consumptions. Improve the efficiency. Energy efficiency, minimized costs and high system availability

More information

Current transformers (CT) & Shunts

Current transformers (CT) & Shunts Current transformers (CT) & Shunts Genreal overview LV CURRENT TRANSFORMERS Product selection guide Standard industrial transformers?????? TCR - TCRO range NEW 9 9 9 Current summation JVM 0 9 TCR usbar

More information

How To Build A Low Voltage Capacitor Lvcp

How To Build A Low Voltage Capacitor Lvcp Low Voltage Capacitor LVCP The new choice for Power Factor Correction LVCP : the new choice for Power Factor Correction The LVCP is a compact and powerful capacitor. It offers high modularity, unmatched

More information

keep your measure under control

keep your measure under control INSTRUMENTACIÓN INDUSTRIAL ZURC, S.A. keep your measure under control CURRENT For measuring instruments. Mounted in selfexinguishing, plastic, strengthened cases. Isolation voltage V Made as per UNEEN

More information

Measurement and Instrumentation

Measurement and Instrumentation POWER QUALITY ENERGY PERFORMANCE Measurement and Instrumentation Transformers and shunts Transformers Overview of ranges Selection guide Info & advice Standard industrial transformers TCR TCRO ranges Adaptable

More information

LOW-VOLTAGE CURRENT TRANSFORMERS

LOW-VOLTAGE CURRENT TRANSFORMERS LOWVOLTAGE CURRENT TRANSFORMERS 5 A Power network meters ND0 and ND type. N4Z and N5Z Tel: (+48 68) 45 75 39; 45 75 305; 45 75 3; 45 75 368; email: export@lumel.com.pl ul. Słubicka 657 Zielona Góra CONTENTS

More information

KOLMA and IHDA Indoor type Cable Current Transformers Catalogue ABB Power Distribution ABB Transmit 1 KKOLMA 1 GB

KOLMA and IHDA Indoor type Cable Current Transformers Catalogue ABB Power Distribution ABB Transmit 1 KKOLMA 1 GB KOLMA and IHDA Indoor type Cable Current Transformers Catalogue ABB Power Distribution ABB Transmit 1 KKOLMA 1 GB KOLMA and IHDA Indoor Type Cable Current Transformers Index Description... 3 Technical

More information

Quick Connect. quick - simple - efficient. www.g-mw.de

Quick Connect. quick - simple - efficient. www.g-mw.de Quick Connect quick - simple - efficient www.g-mw.de Phone: +49 9103 7129-0 Fax: +49 9103 7129-207 Innovative connection technology to plug three single-phase current transformers to multifunctional power

More information

Medium-voltage transformers

Medium-voltage transformers Medium-voltage transformers We make energy measurable and take care of your future www.mbs-ag.com Page 2 E-Mail: info@mbs-ag.com Web: www.mbs-ag.com Contents Current transformers Technical characteristics

More information

Kit 106. 50 Watt Audio Amplifier

Kit 106. 50 Watt Audio Amplifier Kit 106 50 Watt Audio Amplifier T his kit is based on an amazing IC amplifier module from ST Electronics, the TDA7294 It is intended for use as a high quality audio class AB amplifier in hi-fi applications

More information

PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES

PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES BUSHING WITH PLUG CONNECTION WITH OUTER CONE PPS CHARACTERISTICS The PPS bushing can be used as a fixed section for the entry of medium

More information

Electro-pneumatic control valves

Electro-pneumatic control valves Electropneumatic control valves 7 Miniature solenoid valves for alternating current Conform to the Low Voltage Directive or mounting on subbase or footprint in accordance with CNOMO recoendation E 066120N

More information

ISL Insulation monitoring devices Continuous monitoring of IT systems from photovoltaic to industrial applications.

ISL Insulation monitoring devices Continuous monitoring of IT systems from photovoltaic to industrial applications. ISL Insulation monitoring devices Continuous monitoring of IT systems from photovoltaic to industrial applications. Ensuring operational continuity To ensure the operational continuity of an electrical

More information

Vario-Series Accessories

Vario-Series Accessories Accessories and spare parts for GMW analogue panel meters and controllers Current Transformers pages 2-9 Shunt Resistors 10-11 Voltage Dividers 12 Power supply for indicator/controllers 13 Blanking Plates

More information

LOW VOLTAGE RING TYPE MEASURING CURRENT TRANSFORMERS

LOW VOLTAGE RING TYPE MEASURING CURRENT TRANSFORMERS Specification for LOW VOLTAGE RING TYPE MEASURING CURRENT TRANSFORMERS CEYLON ELECTRICITY BOARD SRI LANKA Specification for LOW VOLTAGE RING TYPE MEASURING CURRENT TRANSFORMERS CEB Standard 027: 1998 CEYLON

More information

Current & Instrument Transformers

Current & Instrument Transformers Reliable & Accurate Inputs for Measuring & Protection Equipment Current & Instrument Transformers Type MKE11 Inside the Catalogue Range Specifications Ordering Code Delivering Value to You M-Kris Electric

More information

NIVOCONT CONDUCTIVE LEVEL SWITCHES LEVEL SWITCHES

NIVOCONT CONDUCTIVE LEVEL SWITCHES LEVEL SWITCHES NIVOCONT CONDUCTIVE LEVEL SWITCHES O U R P R O F E S S I O N I S Y O U R L E V E L LEVEL SWITCHES APPLICATION Level switches, based on the conductivity principle, can be applied to liquids with conductivity

More information

Z-TRAUQ INC. Tel.: (450)226-6997 Fax: (450)226-5837 z-trauq@qc.aira.com

Z-TRAUQ INC. Tel.: (450)226-6997 Fax: (450)226-5837 z-trauq@qc.aira.com CURRENT TRANSFORMER MODEL J " x 7" PAGE No 2-2 REV 8DEC00 TERMINAL OPTION LEAD WIRE OPTION 8-2 BRASS SCREW TERMINALS (2 PLACES) SEE NOTE 9 6 9 8 6 Ø 2 9 (4 PLACES) UL 05 #6 AWG LEAD WIRE, STANDARD LENGTH

More information

A project to optimise quality and energy efficiency must include metering

A project to optimise quality and energy efficiency must include metering EMDX 3 : Energy Metering A project to optimise quality and energy efficiency must include metering Metering upstream identifies the critical points and ensures optimum targeting of the actions to be taken,

More information

PSR The compact range Description

PSR The compact range Description Description The PSR range is the most compact of all the ABB softstarter ranges, thereby making it possible to fit many devices into the same enclosure. The system concept with Manual Motor Starters provides

More information

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS) MILLENIUM Table of contents 1. INTRODUCTION 1 2. HARDWARE DESCRIPTION 2 3. INSTALLATION 5 4. CONNECTION 6 5. USER SAFETY AND PROTECTION OF EQUIPMENT 8 1. Introduction The MILLENIUM series has been designed

More information

ELECTROMAGNETIC DISC BRAKES

ELECTROMAGNETIC DISC BRAKES ELECTROMAGNETIC DISC BRAKES TYPE 66E 15/30 52.121 Hand release Lining wear adjustment Torque adjustment 4 holes ø13 DISC SIZE Ø A Braking torque Nm Regulated from (40-100%) Reaction on the shaft N Control

More information

Temperature sensor with integrated transmitter for industrial applications, MBT 3560

Temperature sensor with integrated transmitter for industrial applications, MBT 3560 Temperature sensor with integrated transmitter for industrial applications, MBT 3560 Technical brochure Features Designed for use in harsh industrial enviroments where reliable, robust and accurate equipment

More information

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact Data sheet Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact The CT-AHD.12 is an electronic time relay with OFF-delay. It is from the CT-D range. With their MDRC profile and a width of only

More information

Enhanced Quality with a Touch of Style

Enhanced Quality with a Touch of Style Rudolf Current Transformer Enhanced Quality with a Touch of Style Current Transformer Enhanced Quality with a Touch of Style New Products Rudolf launched our new encapsulated current transformer. Portraying

More information

Single-phase (220...240 V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

Single-phase (220...240 V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable Features 70.11 70.31 70.41 Electronic voltage monitoring relays for single and three-phase applications Multifunctional types, providing the flexibility of monitoring Undervoltage, Overvoltage, Window

More information

Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument 4921210109D

Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument 4921210109D 7000/7000C/7020 Multi-instrument 4921210109D Features Measurements All 3-phase AC measurements True RMS Replaces analogue meters Demand on each phase current Accuracy U, I and F class 0.5 Other values

More information

Pressure monitoring equipment for oil-sf 6. bushings, type GOEK

Pressure monitoring equipment for oil-sf 6. bushings, type GOEK Pressure monitoring equipment for oil-sf 6 bushings, type GOEK Installation and maintenance guide 5693 827-6 en, Rev. 3, 2002-01-30 This document must not be copied without our written permission, and

More information

Product data sheet. JUMO MIDAS Pressure Transmitter. Sales No. Order code JUMO AS 40.1001 401001/000-459-405-502-20-601-61

Product data sheet. JUMO MIDAS Pressure Transmitter. Sales No. Order code JUMO AS 40.1001 401001/000-459-405-502-20-601-61 Produktdatenblatt - JUMO MIDAS Pressure Transmitter JUMO AS Street address: Solheimveien 50, 1470 Lørenskog, Norway Phone: +47 67 97 37 10 Delivery address: Solheimveien 50, 1470 Lørenskog, Norway Fax:

More information

Model CS 64 Mini-DIN Cable and Adaptor

Model CS 64 Mini-DIN Cable and Adaptor Model CS 64 Mini-DIN Cable and Adaptor Page 1 of 9 Features Hi-Pro and NOAHlink compatible cable & Mini-DIN CS 64 Clip Module / NOAHlink Adaptor #1 Integrated Clip Module - Mini-DIN Cable Integrated NOAHlink

More information

T 3000. Substation Maintenance and Commissioning Test Equipment

T 3000. Substation Maintenance and Commissioning Test Equipment T 3000 Substation Maintenance and Commissioning Test Equipment Multi function system for testing substation equipment such as: current, voltage and power transformers, all type of protection relays, energy

More information

RM17TE 183...528 V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

RM17TE 183...528 V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC Characteristics multifunction control relay RM17-TE - range 183..528 V AC Complementary Reset time Maximum switching voltage Minimum switching current Maximum switching current [Us] rated supply voltage

More information

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2... Magnetic and Hydraulic-Magnetic Circuit Breaker 840-G2... Description Single, two and three pole magnetic circuit breakers with trip-free mechanism and push/pull on/off manual actuation. A choice of fast

More information

Type: EASY719 DC RC Article No.: 274119. Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

Type: EASY719 DC RC Article No.: 274119. Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description Type: EASY719 DC RC Article.: 274119 Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC Description 12 digital inputs (4 inputs available as analog inputs) 6 relay outputs LCD display

More information

ISIO 200. Binary Input/Output (I/O) Terminal with IEC 61850 Interface

ISIO 200. Binary Input/Output (I/O) Terminal with IEC 61850 Interface ISIO 200 Binary Input/Output (I/O) Terminal with IEC 61850 Interface Compact and Easy ISIO 200 Put your Binary I/Os where you need them ISIO 200 is a simple and versatile binary I/O terminal with IEC 61850

More information

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q605 0054 R0001

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q605 0054 R0001 Analogue Input, -fold, MDRC, GH Q605 005 R0001 The analogue input is a DIN rail mounted device for insertion in the distribution board. It is connected to the EIB via the bus connecting terminal supplied.

More information

Pluggable interface relays CR-P Pcb relays

Pluggable interface relays CR-P Pcb relays 2CDC 293 034 F0004 1 2 4 3 Features 9 different supply s: DC versions: 12 V, 24 V, 48 V, 110 V AC versions: 24 V, 48 V, 110 V, 120 V, 230 V Output contacts: 1 c/o (16 A) or 2 c/o (8 A) Cadmium-free contact

More information

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information. Product and Applications Description The power supply units N 125/x2 can supply DC 24 V power from an additional pair of terminals (yellowwhite). This DC 24 V output voltage can be used to power e.g. an

More information

B MOTORSPORT COMPONENTS B13. Max Circuit Measurement Characteristic Current Thread Part Number Range Curve [A] Size Connector Figure Comment

B MOTORSPORT COMPONENTS B13. Max Circuit Measurement Characteristic Current Thread Part Number Range Curve [A] Size Connector Figure Comment B MOTORPORT COMPONENT B TEMPERATURE ENOR Purpose and unction Temperature sensors used in modern engine management systems are of NTC [negative temperature co-efficient] design. imply as temperature rises

More information

Switch Actuator, 8-fold, 10 A, MDRC AT/S 8.10.1, GH Q631 0075 R0111

Switch Actuator, 8-fold, 10 A, MDRC AT/S 8.10.1, GH Q631 0075 R0111 , GH Q631 0075 R0111 The 8-fold switch actuator is a DIN rail mounted device for insertion in the distribution board. It is connected to the EIB via a bus terminal. In the event of bus voltage failure,

More information

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw 4 937 DESIO Current valve for AC 24 V pulse/pause control of electrical loads up to 30 kw SEA45.1 Use The current valve is used for the control of electric heating elements in heating, ventilation and

More information

Tape Wound, Split Core and Ebony Current Transformers

Tape Wound, Split Core and Ebony Current Transformers Tape Wound, Split Core and Ebony Current Transformers Current Transformers Contents Page Tape Wound Measuring and Protection Current Transformers 2 6 Split Core Current Transformers 7 9 3-in-1 Current

More information

3/2-way Solenoid Valve, direct-acting, NC or NO

3/2-way Solenoid Valve, direct-acting, NC or NO 3/2-way Solenoid Valve, direct-acting, NC or NO Electrical connection cable plug, Form A With or without manual override as standard Threaded port and sub-base s Impulse optional Type 6014 can be combined

More information

RM4TG20 three-phase network control relay RM4-T - range 200..500 V

RM4TG20 three-phase network control relay RM4-T - range 200..500 V Characteristics three-phase network control relay RM4-T - range 200..500 V Complementary [Us] rated supply voltage Output contacts Setting accuracy of time delay Delay at power up Measuring cycle Marking

More information

C13 User Manual Document ID: 2CMC486004M0201 Revision: A 2013-06-19

C13 User Manual Document ID: 2CMC486004M0201 Revision: A 2013-06-19 C13 C13 Document ID: 2CMC486004M0201 2013-06-19 Disclaimer Copyrights Trademarks Contact The information in this document is subject to change without notice and should not be construed as a commitment

More information

Maximum Demand Control

Maximum Demand Control Maximum Demand Control There are three terms that appear on the majority of electric company bills: Active energy consumption (kwh) Reactive energy consumption (kvarh) Maximum Demand Traditionally, utility

More information

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features: Application : RISH Master 3490 DS measures important electrical parameters of Utility (in normal mode) & Generators (in Power back up) in three phase and single phase Network & replaces the multiple analog

More information

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1 Power Supply Unit, Primary Switched, Narrow Design MINI POWER provides: Extra narrow design with widths of 22.5 mm, 45 mm, and 67.5 mm (0.886, 1.772, and 2.657 in.) Global use due to a wide-range input

More information

SURGE PROTECTIVE DEVICES

SURGE PROTECTIVE DEVICES SURGE PROTECTIVE DEVICES 1. INTRODUCTION In order to ensure safety of people, protection of equipment and, to a certain extent, continuity of supply, insulation co-ordination aims at reducing the likelihood

More information

Material: Weight: Bearing Life: Shaft Speed: Starting Torque: Mass Moment of Inertia: Shaft Loads:

Material: Weight: Bearing Life: Shaft Speed: Starting Torque: Mass Moment of Inertia: Shaft Loads: Automation / Mini Type SCH32F Hollow Shaft Encoder - Ø 32 mm Hollow Bore: Ø 6 mm to Ø 3/8 inch Resolution up to 5000 ppr IP 65 (IP 50 for IDC connector option) Electrical Specifications Code: Resolution:

More information

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER Application : The RISH CON - Hz transducer is used for frequency measurement. The output signal is proportional to measured frequency and is either load independent DC Current or load independent DC Voltage.

More information

Technical data UNIBLOCK UBSF 180 625

Technical data UNIBLOCK UBSF 180 625 Data TECHNICL DT Technical data UNIBLOCK UBSF 80 6 Output data Type UBSF 80 UBSF 0 UBSF 00 UBSF 6 Output power 80 kv 0 kv 00 kv 6 kv Output voltage 80/77 V 0/ V 0/ V 0/ V Output current 7 8 66 80 Power

More information

38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A

38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A 38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A 38 SERIES Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit EMR Electromechanical

More information

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: 2868567. DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: 2868567. DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase Extract from the online catalog STEP-PS/1AC/12DC/1.5 Order No.: 2868567 DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase Commercial data EAN 4046356292924 Pack 1 pcs. Customs tariff

More information

38 SERIES. Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.

38 SERIES. Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6. 38 Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A 38 Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit 6.2 mm wide EMR - DC, AC or AC/DC

More information

Tape Wound, Split Core and Ebony Current Transformers

Tape Wound, Split Core and Ebony Current Transformers Tape Wound, Split Core and Ebony Current Transformers Table of contents Tape Wound Measuring and Protection Current Transformers 2 MR Series Measuring Range 3 PR Series Protection Range 4 Class PX Current

More information

SMS 4 / SMS 5 safety mat Product information

SMS 4 / SMS 5 safety mat Product information SMS 4 / SMS 5 safety mat Product information SMS 4 / SMS 5 safety mats Safety mats are used for the protection of man on machinery and plants with hazardous movements. Typical fields of application are,

More information

NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals

NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101433D0201 28/03/11 NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals NF(Z) contactor relays are used for switching auxiliary and control circuits.

More information

CURRENT TRANSFORMER MODEL 546 UL1015 #16 AWG LEAD WIRE, STANDARD LENGTH IS 24" 1 X

CURRENT TRANSFORMER MODEL 546 UL1015 #16 AWG LEAD WIRE, STANDARD LENGTH IS 24 1 X CURRENT TRANSFORMER MODEL 546 1.10" I.D. PAGE No 1-38 REV 15DEC00 TERMINAL OPTION LEAD WIRE OPTION 1.10 0 1.20 2.55 3.00 3.47 0.18 x 0.31 SLOT ( 2 PLACES) 8-32 BRASS STUD (2 PLACES) UL1015 #16 AWG LEAD

More information

Position Transducers with Restoring Spring 10, 25, 50, 75, 100 mm TR, TRS Series

Position Transducers with Restoring Spring 10, 25, 50, 75, 100 mm TR, TRS Series Position Transducers with Restoring Spring 10, 25, 50, 75, 100 mm TR, TRS Series Special features long life 100 x 10 6 movements outstanding linearity up to ±0.075% choice of plug or cable connection DIN

More information

R.C.C.B. s two-pole LEXIC

R.C.C.B. s two-pole LEXIC 87045 LIMOGES Cedex Telephone : (+33) 05 55 06 87 87 Fax : (+ 33) 05 55 06 88 88 R.C.C.B. s two-pole LEXIC 089 06/09/10/11/12/15/16/17/18/ 27/28/29/30/35, CONTENTS PAGES 1. Electrical and mechanical characteristics...

More information

Catalog EN. Content Transformers for industrial applications

Catalog EN. Content Transformers for industrial applications Catalog Ed. 2013 Catalog Content Transformers for industrial applications Technical information 5 Quick product selection card Single and three-phase transformers 6 Quick product selection card Single-phase

More information

15 Series - Electronic step relay and dimmer. Features 15.91 15.51 15.81 SERIE

15 Series - Electronic step relay and dimmer. Features 15.91 15.51 15.81 SERIE Series - Electronic step relay and dimmer SERIE Features.91.51.81 Electronic step relay and dimmer for control of lighting levels Suitable for incandescent and halogen lighting loads (with or without transformer

More information

Digital Pressure Measuring Instrument MDR480

Digital Pressure Measuring Instrument MDR480 Description The digital panel instrument MDR480 is designed to measure, display, and monitor pressures in industrial applications. The instrument is panel mounted with a front frame dimension of 96 mm

More information

Electronic overload relay EF19 and EF45

Electronic overload relay EF19 and EF45 Data sheet Electronic overload relay EF19 and EF45 Electronic overload relays offer reliable protection in case of overload and phase-failure. They are the alternative to thermal overload relays. Motor

More information

How To Choose A Transformer

How To Choose A Transformer Consider open loop MV network as an example source 1 source 2 NC NC NC or NO main MV switchboard A B Detail design of substation NC NC NC NO NC NC switchboard 1 switchboard 2 switchboard 3 MV MV MV LV

More information

VEO. V4PF480Y/277VSYTK02 Art.Nr.: 2104200. V4PF480Y/277VSYTK02P Art.Nr.: 2104210 TECHNICAL DATA

VEO. V4PF480Y/277VSYTK02 Art.Nr.: 2104200. V4PF480Y/277VSYTK02P Art.Nr.: 2104210 TECHNICAL DATA Monitoring of phase sequence and phase loss Monitoring of asymmetry Temperature monitoring (PTC) Supply voltage 208-480 V AC Supply circuit = measuring circuit 2 change-over contacts Width 45 mm Control

More information

RM35UA13MW. range 15..600 V. Main. Product or component type. Relay monitored parameters

RM35UA13MW. range 15..600 V. Main. Product or component type. Relay monitored parameters Characteristics multifunction voltage control relay RM35-U - range 15..600 V Complementary Reset time Maximum switching voltage [Us] rated supply voltage Supply voltage limits Power consumption in W Main

More information

Technical Description. Transistor D.C. Chopper Controller Type GS 24 S

Technical Description. Transistor D.C. Chopper Controller Type GS 24 S Technical Description Transistor D.C. Chopper Controller Type GS 24 S Table of contents 1. Getting started guide 2. General information 2.1. Characteristics 2.2. Accessories 3. Information about the Machine

More information

Series 6000 Torque measured metal bellow coupling

Series 6000 Torque measured metal bellow coupling Properties Free of float metal bellow coupling with integrated torque measurement Non-contact measurement system, high robustness High torsional stiffness Limited torque of inertia Performance Measurement

More information

servo-controlled 3-WaY vacuum solenoid valves WiTH

servo-controlled 3-WaY vacuum solenoid valves WiTH servo-controlled 3-WaY vacuum solenoid s WiTH low absorption electric coil The 3-way vacuum solenoid s in this series feature two positions with pneumatically pilot-operated conical shutters. They can

More information

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors Unit features Safety features Gertebild ][Bildunterschrift_NOT_Sch.tuer_Licht Safety relay for monitoring E-STOP pushbuttons, safety gates and light beam devices Approvals Gertemerkmale Positive-guided

More information

Electronic timer CT-VBS.17+18 OFF-delayed without auxiliary voltage, for DC contactors Data sheet

Electronic timer CT-VBS.17+18 OFF-delayed without auxiliary voltage, for DC contactors Data sheet Characteristics Single-function OFF-delay timer for DC contactors, without auxiliary voltage Width.5 mm CDC 5 6 F3 Approvals A culus E CCC CT-VBS a Circuit diagram b Marker label Marks a CE b C-Tick Order

More information

MOUNTING AND OPERATING INSTRUCTIONS

MOUNTING AND OPERATING INSTRUCTIONS MOUNTING AND OPERATING INSTRUCTIONS CF 51/55 1. Delivery CF 51/55-1 calculator with battery (optionally with mains power supply) - 1 wall mounting bracket - package with material for sealing, screws, wall

More information

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous Safety relay for monitoring E-STOP pushbuttons. Approvals Unit features Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous 1 auxiliary contact (N/C), instantaneous Safe separation of

More information

3/2- and 2/2-way cartridge valve type BVE

3/2- and 2/2-way cartridge valve type BVE 3/2- and 2/2-way cartridge valve type BVE for any flow direction, zero leakage, all ports pressure resistant Flow Q max = 70 lpm Perm. pressure p max = 400 bar Additional valves with same function: ' Type

More information

DRM75A 230V 20/100A DIN rail single phase two wire energy meter

DRM75A 230V 20/100A DIN rail single phase two wire energy meter DRM75A 230V 20/100A DIN rail single phase two wire energy meter 1.1 Safety instruction 1.2 Foreword 1.3 Performance criteria 1.4 Specifications 1.5 Basic errors 1.6 Description 1.7 Dimensions 1.8 Installation

More information

LENORD. +BAUER... automates motion. PowerDRIVE-Positioning GEL 6109 Compact positioning drive for installation situations with limited space

LENORD. +BAUER... automates motion. PowerDRIVE-Positioning GEL 6109 Compact positioning drive for installation situations with limited space PowerDRIVE-Positioning GEL 6109 Compact positioning drive for installation situations with limited space LENORD +BAUER... automates motion. Technical information Version 2014-09 General The PowerDRIVE-Positioning

More information

Low voltage transformers

Low voltage transformers Low voltage transformers Open core CT SMART OBJECTS Time sensors Detect the signals, where they rise Low voltage transformers In the practice of industrial electrical measurement, some devices of the measurement

More information

Thermal-Magnetic Circuit Breaker 3120-...-M1-..

Thermal-Magnetic Circuit Breaker 3120-...-M1-.. Thermal-Magnetic Circuit Breaker -...-M-.. Description Single or two pole rocker switch/thermal-magnetic circuit breaker with trip-free mechanism (S-type TM CBE to EN 34). The addition of a magnetic tripping

More information

APPENDIX A PIN-OUT OF RJ12 / RJ45 CONNECTORS. RJ12 connectors

APPENDIX A PIN-OUT OF RJ12 / RJ45 CONNECTORS. RJ12 connectors APPENDIX APPENDIX A PIN-OUT OF RJ12 / RJ45 CONNECTORS RJ12 connectors Pin # 1 Signal Name Not Used 2 +TR Description + Data Line 3 +R Remote OFF Required or Remote OFF control 4 -TR 5 Not Used 6 RTN -

More information

AF09-30-22-.. / AF09Z-30-22-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals

AF09-30-22-.. / AF09Z-30-22-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101403D0201 24/03/11 AF09-30-22-.. / AF09Z-30-22-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals AF09(Z) contactors are used for controlling power circuits

More information

HERZ-Thermal Actuators

HERZ-Thermal Actuators HERZ-Thermal Actuators Data Sheet 7708-7990, Issue 1011 Dimensions in mm 1 7710 00 1 7710 01 1 7711 18 1 7710 80 1 7710 81 1 7711 80 1 7711 81 1 7990 00 1 7980 00 1 7708 11 1 7708 10 1 7708 23 1 7709 01

More information

Using Current Transformers with the 78M661x

Using Current Transformers with the 78M661x A Maxim Integrated Products Brand Using Current Transformers with the 78M661x APPLICATION NOTE AN_661x_021 April 2010 Introduction This application note describes using current transformers (CT) with the

More information

Sensors. Sensors. All Cylinders. Specifications. Features: Features Type REED HALL EFFECT NPN or PNP. Ø8mm - 125mm

Sensors. Sensors. All Cylinders. Specifications. Features: Features Type REED HALL EFFECT NPN or PNP. Ø8mm - 125mm Specifications Features Type REED HALL EFFECT NPN or PNP Applicable Series Configurations Construction Materials Body Mounting Bracket Cable Characteristics Operating Temperature Accuracy All Cylinders

More information

HARDWARE MANUAL. Ixx24-A 1/20. Val Controls A/S Limfjordsvej 3 DK-6715 Esbjerg N Tel. +45 7547 0600 vc@valcontrols.com www.valcontrols.

HARDWARE MANUAL. Ixx24-A 1/20. Val Controls A/S Limfjordsvej 3 DK-6715 Esbjerg N Tel. +45 7547 0600 vc@valcontrols.com www.valcontrols. HARDWARE MANUAL Ixx24-A 1/20 Table of contents 1 General... 3 1.1 Safety instructions... 3 1.2 Environment... 3 1.3 Mounting and dimension... 3 2 Communication... 4 2.1 Control loop AI0 and Transmitter

More information

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com Product description Wide rated operational voltage 208 600 V AC Wide rated control supply voltage 100 250 V, 50/60 Hz Rated operational current 18 to 370 A Wide ambient temperature range, -25 to +60 ºC

More information

0.84" x 2.00" Z-TRAUQ INC. Tel.: (450)226-6997 Fax: (450)226-5837 z-trauq@qc.aira.com SPLIT CORE CURRENT TRANSFORMER MODEL 1SP.

0.84 x 2.00 Z-TRAUQ INC. Tel.: (450)226-6997 Fax: (450)226-5837 z-trauq@qc.aira.com SPLIT CORE CURRENT TRANSFORMER MODEL 1SP. SPLIT CORE CURRENT MODEL 1SP 0.84" x 2.00" PAGE No 3-2 REV 18DEC00 UL 1015 LEAD WIRE, STANDARD LENGTH IS 36 E DIMENSIONS A = 0.84 MIN B = 2.00 MIN C = 3.31 MAX D = 3.09 MAX E = 0.61 MAX F = 0 MAX F C B

More information

38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A

38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A 38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit EMR Electromechanical Relays

More information

H/L = Power supply. FN = Nominal Frequency. RN = Rated value of output burden. UN = Nominal input voltage. IN = Nominal input current.

H/L = Power supply. FN = Nominal Frequency. RN = Rated value of output burden. UN = Nominal input voltage. IN = Nominal input current. Application : The transducer RISH CON - CA/CV (Fig.1) converts a sinusoidal AC Current or AC Voltage into a load independent DC Current or a load independent DC Voltage proportional to the measured value.

More information

Electric Rotary Actuator - On/Off or programmable control actuator

Electric Rotary Actuator - On/Off or programmable control actuator Electric Rotary Actuator - On/Off or programmable control actuator Direct mounting on quarter-turn valves Manual override standard Corrosion resistant Adjustable limit switches Multi-voltage version Type

More information

Features. Picture. Specifications

Features. Picture. Specifications Type: for level measurement Order No.: see Table 1 / Page 4 Features Picture Two wire system Piezoresistive measuring element Output signal 4-20 ma Conformity error ±0.5 % FS or Standard DIN measuring

More information

Proportional pressure regulators VPPE

Proportional pressure regulators VPPE Proportional pressure regulators VPPE Proportional pressure regulators VPPE Product range overview Function Version Pneumatic connection Proportional pressure regulator Nominal size for pressurisation/

More information

Top Microsystems Proprietary Specification P/N: W090015HK-XP 022410RB-082709V.A0 SPECIFICATION

Top Microsystems Proprietary Specification P/N: W090015HK-XP 022410RB-082709V.A0 SPECIFICATION SPECIFICATION High Quality Switching Wallmount Adapter Interchangeable AC Plugs 90-264VAC Input 13.5W 9VDC 1.5A Output P/N: W090015HK-XP ** Specification Approval** This specification (total 11 pages including

More information

PCB transformers. Short circuit proof PCB transformer VB. General Data. Advantages. Applications. Circuit diagram. Standards & 1 Certifications W v

PCB transformers. Short circuit proof PCB transformer VB. General Data. Advantages. Applications. Circuit diagram. Standards & 1 Certifications W v Short circuit PCB transformer General Data Rated input 230 Vac Rated output 6-2 x 24 Vac Rated power 0.35-3.2 VA Insulation class B Maximum ambient temperature 70 C Efficiency up to 58 % Degree of protection

More information

AIR-AIR PRESSURE MULTIPLIER (BOOSTER)

AIR-AIR PRESSURE MULTIPLIER (BOOSTER) AIR-AIR PRESSURE MULTIPLIER (BOOSTER) The air-air pressure multiplier, or booster, is an automatic device that compresses air to give an outlet pressure that is double the inlet pressure. It is normally

More information

3-phase, bidirectional energy meter

3-phase, bidirectional energy meter Data sheet www.sbc-support.com 3-phase, bidirectional energy meter with S0 pulse output Bidirectional energy meter with S0-interface. The S0 interface is a hardware interface for the transmission of measured

More information

EMO T. Thermal actuator for heating, ventilation and air conditioning systems

EMO T. Thermal actuator for heating, ventilation and air conditioning systems EMO T Thermal actuator for heating, ventilation and air conditioning systems Pressurisation & Water Quality Balancing & Control Thermostatic Control ENGINEEING ADVANTAGE EMO T Description The EMO T thermal

More information

RY2 miniature industrial relays

RY2 miniature industrial relays 6 RY2 Relays of general application For plug-in sockets, 35 mm rail mount acc. to PN-EN 60715 or on panel mounting Flat insert connectors - faston x 0,5 mm Recognitions, certifications, directives: RoHS,

More information

Reaction Torque Sensor

Reaction Torque Sensor Force 1 1 N m up to 1 000 1 000 N m Type 9329A 9389A These easy to install piezoelectric reaction torque sensors are particularly suitable for measuring rapidly changing torques at non-rotating shafts.