Measurement devices Accessories for analogue and digital instruments
|
|
- Anna Dalton
- 7 years ago
- Views:
Transcription
1 Accessories for analogue and digital instruments 1 2CSC96F0001 Current transformers Used to transform primary currents (max A) into.../5 A and.../1 A low secondary currents indirectly supplying power to analogue and digital measurement devices. They are available both with wound and through primary. In the first case they are provided along with the bar or the primary terminal; in the second case they have a hole to insert in the bar or the cable which forms the primary. Standard type current transformers Code Type Code Type Description Current transformer with wound primary, primary and secondary current on terminals - - EQ 36 8 CTA/1-1 Iprim 1 A, 0.5 rating 5 VA, rating 1 7 VA EH CTA/5 EQ 37 6 CTA/5-1 Iprim 5 A, 0.5 rating 5 VA, rating 1 7 VA EH CTA/10 EQ 38 CTA/10-1 Iprim 10 A, 0.5 rating 5 VA, rating 1 7 VA EH CTA/15 EQ 39 2 CTA/15-1 Iprim 15 A, 0.5 rating 5 VA, rating 1 7 VA EH CTA/20 EQ CTA/20-1 Iprim 20 A, 0.5 rating 5 VA, rating 1 7 VA EH CTA/25 EQ CTA/25-1 Iprim 25 A, 0.5 rating 5 VA, rating 1 7 VA EH CTA/0 EQ 353 CTA/0-1 Iprim 0 A, 0.5 rating 5 VA, rating 1 7 VA EH 02 1 CTA/ EQ 35 2 CTA/-1 Iprim A, 0.5 rating 5 VA, rating 1 7 VA EH CTA/60 EQ CTA/60-1 Iprim 60 A, 0.5 rating 5 VA, rating 1 7 VA EH CTA/80 EQ CTA/80-1 Iprim 80 A, 0.5 rating 5 VA, rating 1 7 VA EH 027 CTA/100 EQ CTA/100-1 Iprim 100 A, 0.5 rating 5 VA, rating 1 7 VA Technical characteristics Standard secondary current [A] 5 (other secondary on request) Max. voltage for operation 1 [kv] 1.2 (0.72 for compact version) Test voltage 2 [kv] 6 at Hz/1 min. (3 for compact version) Short circuit rated thermal current I min 3 [IpN] 0 for 1 sec. Short circuit rated dynamic current I min [I ter ] 2.5 for 1 sec. Permanent overload [IpN] 1.2 Safety factor 5 [Fs] 2 at 10 according to version and capacity Frequency [Hx] /60 Air insulation Terminals 6 Housing Protection degree E class primary = P1, P2 (K-L) secondary = s1, s2 (k-l) P1 (K)=primary wound input P2 (L)=primary wound output s1 (k)=secondary wound input s2 (l)=secondary wound output with double ration on secondary s1-s2=lower ratio, s1-s3=higher ratio ABS resin IP30 Operating temperature [ C] Max. temperature on bars [ C] +70 Storage temperature [ C] Relative humidity 80% 1 Max. voltage (effective value) the transformer can bear. 2 Industrial frequency voltage in relation to insulation the transformer bears for 1 min. between the primary and the secondary. 3 Max. primary current (effective value) the transformer bears for 1 sec. with counter-circuited secondary without overload-induced damages. Max. primary current (effective value) the transformer bears for 1 sec. with counter-circuited secondary without damaged due to electromagnetic efforts. 5 Ratio between primary current causing nucleus saturation and the rated primary current value: the lower the Sf the higher the protection level on the transformer. 6 Brass terminals CuZn37, Mx6 screws with torsion value 1.9 Nm, tensile value 0 N/mm 2 and elasticity limit 30 N/mm 2. During the installation control the correct input (P1-K) and output (P2-L) direction of the primary cable. On versions with primary and secondary on terminals pay attention the connection of the primary with the secondary is not inverted. In the case of a detachment from measurement devices of the transformer in a connected plant counter-circuit the two terminals of the transformer. It is suggested to earth the transformers. 1/30 ABB SACE
2 Accessories for analogue and digital instruments Code Type Code Type Description - - EQ CTA1/1-1 Iprim 1 A, 0.5 rating 10 VA, rating 1 20 VA EH CTA1/5 EQ CTA1/5-1 Iprim 5 A, 0.5 rating 10 VA, rating 1 20 VA EH CTA1/10 EQ CTA1/10-1 Iprim 10 A, 0.5 rating 10 VA, rating 1 20 VA EH CTA1/15 EQ CTA1/15-1 Iprim 15 A, 0.5 rating 10 VA, rating 1 20 VA EH CTA1/20 EQ CTA1/20-1 Iprim 20 A, 0.5 rating 10 VA, rating 1 20 VA EH CTA1/25 EQ CTA1/25-1 Iprim 25 A, 0.5 rating 10 VA, rating 1 20 VA EH CTA1/0 EQ 36 1 CTA1/0-1 Iprim 0 A, 0.5 rating 10 VA, rating 1 20 VA EH CTA1/ EQ CTA1/-1 Iprim A, 0.5 rating 10 VA, rating 1 20 VA EH CTA1/60 EQ CTA1/60-1 Iprim 60 A, 0.5 rating 10 VA, rating 1 20 VA EH 00 7 CTA1/80 EQ 367 CTA1/80-1 Iprim 80 A, 0.5 rating 10 VA, rating 1 20 VA EH CTA1/100 EQ CTA1/100-1 Iprim 100 A, 0.5 rating 10 VA, rating 1 20 VA EH CTA1/1 EQ CTA1/1-1 Iprim 1 A, 0.5 rating 10 VA, rating 1 20 VA EH CTA1/200 EQ CTA1/200-1 Iprim 200 A, 0.5 rating 10 VA, rating 1 20 VA EH CTA1/2 EQ CTA1/2-1 Iprim 2 A, 0.5 rating 10 VA, rating 1 20 VA EH CTA1/300 EQ 372 CTA1/300-1 Iprim 300 A, 0.5 rating 10 VA, rating 1 20 VA EH CTA1/00 EQ CTA1/00-1 Iprim 00 A, 0.5 rating 10 VA, rating 1 20 VA EH 065 CTA1/0 EQ 37 0 CTA1/0-1 Iprim 0 A, 0.5 rating 10 VA, rating 1 20 VA EQ 3 7 CTA2/1-1 Iprim 1 A, 0.5 rating 10 VA, rating 1 35 VA EH CTA2/5 EQ CTA2/5-1 Iprim 5 A, 0.5 rating 10 VA, rating 1 35 VA EH CTA2/10 EQ CTA2/10-1 Iprim 10 A, 0.5 rating 10 VA, rating 1 35 VA EH CTA2/15 EQ CTA2/15-1 Iprim 15 A, 0.5 rating 10 VA, rating 1 35 VA EH CTA2/20 EQ CTA2/20-1 Iprim 20 A, 0.5 rating 10 VA, rating 1 35 VA EH 070 CTA2/25 EQ CTA2/25-1 Iprim 25 A, 0.5 rating 10 VA, rating 1 35 VA EH CTA2/0 EQ CTA2/0-1 Iprim 0 A, 0.5 rating 10 VA, rating 1 35 VA EH 07 6 CTA2/ EQ CTA2/-1 Iprim A, 0.5 rating 10 VA, rating 1 35 VA EH 0 3 CTA2/60 EQ CTA2/60-1 Iprim 60 A, 0.5 rating 10 VA, rating 1 35 VA EH CTA2/80 EQ 38 9 CTA2/80-1 Iprim 80 A, 0.5 rating 10 VA, rating 1 35 VA EH CTA2/100 EQ CTA2/100-1 Iprim 100 A, 0.5 rating 10 VA, rating 1 35 VA EH CTA2/1 EQ 386 CTA2/1-1 Iprim 1 A, 0.5 rating 10 VA, rating 1 35 VA EH 089 CTA2/200 EQ CTA2/200-1 Iprim 200 A, 0.5 rating 10 VA, rating 1 35 VA EH CTA2/2 EQ CTA2/2-1 Iprim 2 A, 0.5 rating 10 VA, rating 1 35 VA EH CTA2/300 EQ CTA2/300-1 Iprim 300 A, 0.5 rating 10 VA, rating 1 35 VA EH CTA2/00 EQ CTA2/00-1 Iprim 00 A, 0.5 rating 10 VA, rating 1 35 VA EH CTA2/0 EQ 391 CTA2/0-1 Iprim 0 A, 0.5 rating 10 VA, rating 1 35 VA 2CSC97F0001 EH CT3/0 EQ CT3/0-1 Iprim 0 A, 3 rating 2 VA EH CT3/ EQ CT3/-1 Iprim A, 3 rating 2 VA EH CT3/60 EQ 39 8 CT3/60-1 Iprim 60 A, 3 rating 2 VA EH CT3/80 EQ CT3/80-1 Iprim 80 A, 3 rating 3 VA EH CT3/100 EQ CT3/100-1 Iprim 100 A, 1 rating 3 VA EH CT3/1 EQ CT3/1-1 Iprim 1 A, 0.5 rating 3 VA EH CT3/200 EQ CT3/200-1 Iprim 200 A, 0.5 rating 3 VA EH CT3/2 EQ 00 3 CT3/2-1 Iprim 2 A, 0.5 rating 6 VA EH CT3/300 EQ 01 1 CT3/300-1 Iprim 300 A, 0.5 rating 6 VA EH 69 1 CT3/00 EQ 02 9 CT3/00-1 Iprim 00 A, 0.5 rating 6 VA EH CT3/0 EQ 03 7 CT3/0-1 Iprim 0 A, 0.5 rating 6 VA EH CT3/600 EQ 0 5 CT3/600-1 Iprim 600 A, 0.5 rating 6 VA 2CSC5105F0001 EH 697 CT/100 EQ 05 2 CT/100-1 Iprim 100 A, 1 rating 3 VA EH CT/1 EQ 06 0 CT/1-1 Iprim 1 A, 1 rating 3 VA EH CT/200 EQ 07 8 CT/200-1 Iprim 200 A, 0.5 rating VA EH CT/2 EQ 08 6 CT/2-1 Iprim 2 A, 0.5 rating 6 VA EH 701 CT/300 EQ 09 CT/300-1 Iprim 300 A, 0.5 rating 6 VA EH CT/00 EQ 11 0 CT/00-1 Iprim 00 A, 0.5 rating 10 VA EH CT/0 EQ 12 8 CT/0-1 Iprim 0 A, 0.5 rating 10 VA EH 70 8 CT/600 EQ 1 CT/600-1 Iprim 600 A, 0.5 rating 10 VA EH CT/800 EQ 15 1 CT/800-1 Iprim 800 A, 0.5 rating 10 VA EH CT/1000 EQ 16 9 CT/ Iprim 1000 A, 0.5 rating 10 VA ABB SACE 1/31
3 Accessories for analogue and digital instruments 1 2CSC98F0001 Code Type Code Type Description EH CT5/2 EQ 17 7 CT5/2-1 Iprim 2 A, 0.5 rating 3 VA EH CT5/300 EQ 18 5 CT5/300-1 Iprim 300 A, 0.5 rating VA EH CT5/00 EQ 19 3 CT5/00-1 Iprim 00 A, 0.5 rating 6 VA EH CT5/0 EQ 20 1 CT5/0-1 Iprim 0 A, 0.5 rating 10 VA EH CT5/600 EQ 9 CT5/600-1 Iprim 600 A, 0.5 rating 10 VA EH CT5/800 EQ 22 7 CT5/800-1 Iprim 800 A, 0.5 rating 10 VA EH CT5/1000 EQ 23 5 CT5/ Iprim 1000 A, 0.5 rating 10 VA EH 71 7 CT5/1200 EQ 2 3 CT5/ Iprim 1200 A, 0.5 rating 10 VA EH 715 CT5/10 EQ 25 0 CT5/10-1 Iprim 10 A, 0.5 rating 20 VA 2CSC5101F0001 2CSC510F0001 EH CT6/2 EQ 26 8 CT6/2-1 Iprim 2 A, 0.5 rating 5 VA EH CT6/300 EQ 27 6 CT6/300-1 Iprim 300 A, 0.5 rating 5 VA EH CT6/00 EQ 28 CT6/00-1 Iprim 00 A, 0.5 rating 6 VA EH CT6/0 EQ 29 2 CT6/0-1 Iprim 0 A, 0.5 rating 6 VA EH 720 CT6/600 EQ 30 0 CT6/600-1 Iprim 600 A, 0.5 rating 10 VA EH 7 2 CT6/800 EQ 31 8 CT6/800-1 Iprim 800 A, 0.5 rating 10 VA EH CT6/1000 EQ 32 6 CT6/ Iprim 1000 A, 0.5 rating 20 VA EH CT6/1200 EQ 33 CT6/ Iprim 1200 A, 0.5 rating 20 VA EH 72 6 CT6/10 EQ 3 2 CT6/10-1 Iprim 10 A, 0.5 rating 30 VA EH CT6/2000 EQ 35 9 CT6/ Iprim 2000 A, 0.5 rating 30 VA EH CT6/20 EQ 36 7 CT6/20-1 Iprim 20 A, 0.5 rating 30 VA EH CT8/300 EQ 37 5 CT8/300-1 Iprim 300 A, 0.5 rating 5 VA EH CT8/00 EQ 38 3 CT8/00-1 Iprim 00 A, 0.5 rating 6 VA EH CT8/0 EQ 39 1 CT8/0-1 Iprim 0 A, 0.5 rating 10 VA EH CT8/600 EQ 1 7 CT8/600-1 Iprim 600 A, 0.5 rating 10 VA EH CT8/800 EQ 2 5 CT8/800-1 Iprim 800 A, 0.5 rating 10 VA EH CT8/1000 EQ 3 3 CT8/ Iprim 1000 A, 0.5 rating 10 VA EH CT8/1200 EQ 1 CT8/ Iprim 1200 A, 0.5 rating 15 VA EH 73 5 CT8/10 EQ 5 8 CT8/10-1 Iprim 10 A, 0.5 rating 20 VA EH CT8/2000 EQ 6 6 CT8/ Iprim 2000 A, 0.5 rating 20 VA EH CT8/20 EQ 7 CT8/20-1 Iprim 20 A, 0.5 rating 20 VA EH CT8/3000 EQ 8 2 CT8/ Iprim 3000 A, 0.5 rating 20 VA EH 78 5 CT8-V/00 EQ 9 0 CT8-V/00-1 Iprim 00 A, 0.5 rating 6 VA EH 79 3 CT8-V/0 EQ 8 CT8-V/0-1 Iprim 0 A, 0.5 rating 10 VA EH 7 1 CT8-V/600 EQ 51 6 CT8-V/600-1 Iprim 600 A, 0.5 rating 10 VA EH 1 9 CT8-V/800 EQ 52 CT8-V/800-1 Iprim 800 A, 0.5 rating 10 VA EH 2 7 CT8-V/1000 EQ 53 2 CT8-V/ Iprim 1000 A, 0.5 rating 10 VA EH 3 5 CT8-V/1200 EQ 5 0 CT8-V/ Iprim 1200 A, 0.5 rating 10 VA EH 3 CT8-V/10 EQ 56 5 CT8-V/10-1 Iprim 10 A, 0.5 rating 10 VA EH 5 0 CT8-V/2000 EQ 57 3 CT8-V/ Iprim 2000 A, 0.5 rating 20 VA EH 6 8 CT8-V/20 EQ 58 1 CT8-V/20-1 Iprim 20 A, 0.5 rating 20 VA EH CT12/0 EQ 59 9 CT12/0-1 Iprim 0 A, 0.5 rating 10 VA EH 739 CT12/600 EQ 60 7 CT12/600-1 Iprim 600 A, 0.5 rating 10 VA EH 70 2 CT12/800 EQ 61 5 CT12/800-1 Iprim 800 A, 0.5 rating 15 VA EH 71 0 CT12/1000 EQ 63 1 CT12/ Iprim 1000 A, 0.5 rating 20 VA EH 72 8 CT12/1200 EQ 6 9 CT12/ Iprim 1200 A, 0.5 rating 20 VA EH 73 6 CT12/10 EQ 65 6 CT12/10-1 Iprim 10 A, 0.5 rating 20 VA EH 7 CT12/2000 EQ 66 CT12/ Iprim 2000 A, 0.5 rating 30 VA EH 1 CT12/20 EQ 67 2 CT12/20-1 Iprim 20 A, 0.5 rating 0 VA EH 76 9 CT12/3000 EQ 69 8 CT12/ Iprim 3000 A, 0.5 rating 0 VA EH 77 7 CT12/000 EQ 70 6 CT12/000-1 Iprim 000 A, 0.5 rating VA EH 88 8 CT12/00 EQ 71 CT12/00-1 Iprim 00 A, 0.5 rating VA EH CT12/6000 EQ 72 2 CT12/ Iprim 6000 A, 0.5 rating VA 1/32 ABB SACE
4 Standard type current transformers CTA From 1 to 0 A 5 from 0 to 100 A CTA1 TRFM modules CTA M M ø9 60 x35 ø Accessory for fixing on DIN rail ABB SACE /11
5 CT 109 CT5 5 1 CT , Accessory for fixing on DIN rail /12 ABB SACE
6 CT CT8-V ABB SACE /13
7 CT CT12-V /1 ABB SACE
CT Current transformers Ideal for measuring. Designed to create efficiency.
CT Current transformers Ideal for measuring. Designed to create efficiency. CT Current transformers Optimize consumptions. Improve the efficiency. Energy efficiency, minimized costs and high system availability
More informationCurrent transformers (CT) & Shunts
Current transformers (CT) & Shunts Genreal overview LV CURRENT TRANSFORMERS Product selection guide Standard industrial transformers?????? TCR - TCRO range NEW 9 9 9 Current summation JVM 0 9 TCR usbar
More informationHow To Build A Low Voltage Capacitor Lvcp
Low Voltage Capacitor LVCP The new choice for Power Factor Correction LVCP : the new choice for Power Factor Correction The LVCP is a compact and powerful capacitor. It offers high modularity, unmatched
More informationkeep your measure under control
INSTRUMENTACIÓN INDUSTRIAL ZURC, S.A. keep your measure under control CURRENT For measuring instruments. Mounted in selfexinguishing, plastic, strengthened cases. Isolation voltage V Made as per UNEEN
More informationMeasurement and Instrumentation
POWER QUALITY ENERGY PERFORMANCE Measurement and Instrumentation Transformers and shunts Transformers Overview of ranges Selection guide Info & advice Standard industrial transformers TCR TCRO ranges Adaptable
More informationLOW-VOLTAGE CURRENT TRANSFORMERS
LOWVOLTAGE CURRENT TRANSFORMERS 5 A Power network meters ND0 and ND type. N4Z and N5Z Tel: (+48 68) 45 75 39; 45 75 305; 45 75 3; 45 75 368; email: export@lumel.com.pl ul. Słubicka 657 Zielona Góra CONTENTS
More informationKOLMA and IHDA Indoor type Cable Current Transformers Catalogue ABB Power Distribution ABB Transmit 1 KKOLMA 1 GB
KOLMA and IHDA Indoor type Cable Current Transformers Catalogue ABB Power Distribution ABB Transmit 1 KKOLMA 1 GB KOLMA and IHDA Indoor Type Cable Current Transformers Index Description... 3 Technical
More informationQuick Connect. quick - simple - efficient. www.g-mw.de
Quick Connect quick - simple - efficient www.g-mw.de Phone: +49 9103 7129-0 Fax: +49 9103 7129-207 Innovative connection technology to plug three single-phase current transformers to multifunctional power
More informationMedium-voltage transformers
Medium-voltage transformers We make energy measurable and take care of your future www.mbs-ag.com Page 2 E-Mail: info@mbs-ag.com Web: www.mbs-ag.com Contents Current transformers Technical characteristics
More informationKit 106. 50 Watt Audio Amplifier
Kit 106 50 Watt Audio Amplifier T his kit is based on an amazing IC amplifier module from ST Electronics, the TDA7294 It is intended for use as a high quality audio class AB amplifier in hi-fi applications
More informationPPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES
PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES BUSHING WITH PLUG CONNECTION WITH OUTER CONE PPS CHARACTERISTICS The PPS bushing can be used as a fixed section for the entry of medium
More informationElectro-pneumatic control valves
Electropneumatic control valves 7 Miniature solenoid valves for alternating current Conform to the Low Voltage Directive or mounting on subbase or footprint in accordance with CNOMO recoendation E 066120N
More informationISL Insulation monitoring devices Continuous monitoring of IT systems from photovoltaic to industrial applications.
ISL Insulation monitoring devices Continuous monitoring of IT systems from photovoltaic to industrial applications. Ensuring operational continuity To ensure the operational continuity of an electrical
More informationVario-Series Accessories
Accessories and spare parts for GMW analogue panel meters and controllers Current Transformers pages 2-9 Shunt Resistors 10-11 Voltage Dividers 12 Power supply for indicator/controllers 13 Blanking Plates
More informationLOW VOLTAGE RING TYPE MEASURING CURRENT TRANSFORMERS
Specification for LOW VOLTAGE RING TYPE MEASURING CURRENT TRANSFORMERS CEYLON ELECTRICITY BOARD SRI LANKA Specification for LOW VOLTAGE RING TYPE MEASURING CURRENT TRANSFORMERS CEB Standard 027: 1998 CEYLON
More informationCurrent & Instrument Transformers
Reliable & Accurate Inputs for Measuring & Protection Equipment Current & Instrument Transformers Type MKE11 Inside the Catalogue Range Specifications Ordering Code Delivering Value to You M-Kris Electric
More informationNIVOCONT CONDUCTIVE LEVEL SWITCHES LEVEL SWITCHES
NIVOCONT CONDUCTIVE LEVEL SWITCHES O U R P R O F E S S I O N I S Y O U R L E V E L LEVEL SWITCHES APPLICATION Level switches, based on the conductivity principle, can be applied to liquids with conductivity
More informationZ-TRAUQ INC. Tel.: (450)226-6997 Fax: (450)226-5837 z-trauq@qc.aira.com
CURRENT TRANSFORMER MODEL J " x 7" PAGE No 2-2 REV 8DEC00 TERMINAL OPTION LEAD WIRE OPTION 8-2 BRASS SCREW TERMINALS (2 PLACES) SEE NOTE 9 6 9 8 6 Ø 2 9 (4 PLACES) UL 05 #6 AWG LEAD WIRE, STANDARD LENGTH
More informationA project to optimise quality and energy efficiency must include metering
EMDX 3 : Energy Metering A project to optimise quality and energy efficiency must include metering Metering upstream identifies the critical points and ensures optimum targeting of the actions to be taken,
More informationPSR The compact range Description
Description The PSR range is the most compact of all the ABB softstarter ranges, thereby making it possible to fit many devices into the same enclosure. The system concept with Manual Motor Starters provides
More informationMILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)
MILLENIUM Table of contents 1. INTRODUCTION 1 2. HARDWARE DESCRIPTION 2 3. INSTALLATION 5 4. CONNECTION 6 5. USER SAFETY AND PROTECTION OF EQUIPMENT 8 1. Introduction The MILLENIUM series has been designed
More informationELECTROMAGNETIC DISC BRAKES
ELECTROMAGNETIC DISC BRAKES TYPE 66E 15/30 52.121 Hand release Lining wear adjustment Torque adjustment 4 holes ø13 DISC SIZE Ø A Braking torque Nm Regulated from (40-100%) Reaction on the shaft N Control
More informationTemperature sensor with integrated transmitter for industrial applications, MBT 3560
Temperature sensor with integrated transmitter for industrial applications, MBT 3560 Technical brochure Features Designed for use in harsh industrial enviroments where reliable, robust and accurate equipment
More informationElectronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact
Data sheet Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact The CT-AHD.12 is an electronic time relay with OFF-delay. It is from the CT-D range. With their MDRC profile and a width of only
More informationEnhanced Quality with a Touch of Style
Rudolf Current Transformer Enhanced Quality with a Touch of Style Current Transformer Enhanced Quality with a Touch of Style New Products Rudolf launched our new encapsulated current transformer. Portraying
More informationSingle-phase (220...240 V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable
Features 70.11 70.31 70.41 Electronic voltage monitoring relays for single and three-phase applications Multifunctional types, providing the flexibility of monitoring Undervoltage, Overvoltage, Window
More informationFeatures. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument 4921210109D
7000/7000C/7020 Multi-instrument 4921210109D Features Measurements All 3-phase AC measurements True RMS Replaces analogue meters Demand on each phase current Accuracy U, I and F class 0.5 Other values
More informationPressure monitoring equipment for oil-sf 6. bushings, type GOEK
Pressure monitoring equipment for oil-sf 6 bushings, type GOEK Installation and maintenance guide 5693 827-6 en, Rev. 3, 2002-01-30 This document must not be copied without our written permission, and
More informationProduct data sheet. JUMO MIDAS Pressure Transmitter. Sales No. Order code JUMO AS 40.1001 401001/000-459-405-502-20-601-61
Produktdatenblatt - JUMO MIDAS Pressure Transmitter JUMO AS Street address: Solheimveien 50, 1470 Lørenskog, Norway Phone: +47 67 97 37 10 Delivery address: Solheimveien 50, 1470 Lørenskog, Norway Fax:
More informationModel CS 64 Mini-DIN Cable and Adaptor
Model CS 64 Mini-DIN Cable and Adaptor Page 1 of 9 Features Hi-Pro and NOAHlink compatible cable & Mini-DIN CS 64 Clip Module / NOAHlink Adaptor #1 Integrated Clip Module - Mini-DIN Cable Integrated NOAHlink
More informationT 3000. Substation Maintenance and Commissioning Test Equipment
T 3000 Substation Maintenance and Commissioning Test Equipment Multi function system for testing substation equipment such as: current, voltage and power transformers, all type of protection relays, energy
More informationRM17TE 183...528 V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC
Characteristics multifunction control relay RM17-TE - range 183..528 V AC Complementary Reset time Maximum switching voltage Minimum switching current Maximum switching current [Us] rated supply voltage
More informationMagnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...
Magnetic and Hydraulic-Magnetic Circuit Breaker 840-G2... Description Single, two and three pole magnetic circuit breakers with trip-free mechanism and push/pull on/off manual actuation. A choice of fast
More informationType: EASY719 DC RC Article No.: 274119. Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description
Type: EASY719 DC RC Article.: 274119 Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC Description 12 digital inputs (4 inputs available as analog inputs) 6 relay outputs LCD display
More informationISIO 200. Binary Input/Output (I/O) Terminal with IEC 61850 Interface
ISIO 200 Binary Input/Output (I/O) Terminal with IEC 61850 Interface Compact and Easy ISIO 200 Put your Binary I/Os where you need them ISIO 200 is a simple and versatile binary I/O terminal with IEC 61850
More informationAnalogue Input, 4-fold, MDRC AE/S 4.1, GH Q605 0054 R0001
Analogue Input, -fold, MDRC, GH Q605 005 R0001 The analogue input is a DIN rail mounted device for insertion in the distribution board. It is connected to the EIB via the bus connecting terminal supplied.
More informationPluggable interface relays CR-P Pcb relays
2CDC 293 034 F0004 1 2 4 3 Features 9 different supply s: DC versions: 12 V, 24 V, 48 V, 110 V AC versions: 24 V, 48 V, 110 V, 120 V, 230 V Output contacts: 1 c/o (16 A) or 2 c/o (8 A) Cadmium-free contact
More informationProduct and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.
Product and Applications Description The power supply units N 125/x2 can supply DC 24 V power from an additional pair of terminals (yellowwhite). This DC 24 V output voltage can be used to power e.g. an
More informationB MOTORSPORT COMPONENTS B13. Max Circuit Measurement Characteristic Current Thread Part Number Range Curve [A] Size Connector Figure Comment
B MOTORPORT COMPONENT B TEMPERATURE ENOR Purpose and unction Temperature sensors used in modern engine management systems are of NTC [negative temperature co-efficient] design. imply as temperature rises
More informationSwitch Actuator, 8-fold, 10 A, MDRC AT/S 8.10.1, GH Q631 0075 R0111
, GH Q631 0075 R0111 The 8-fold switch actuator is a DIN rail mounted device for insertion in the distribution board. It is connected to the EIB via a bus terminal. In the event of bus voltage failure,
More informationCurrent valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw
4 937 DESIO Current valve for AC 24 V pulse/pause control of electrical loads up to 30 kw SEA45.1 Use The current valve is used for the control of electric heating elements in heating, ventilation and
More informationTape Wound, Split Core and Ebony Current Transformers
Tape Wound, Split Core and Ebony Current Transformers Current Transformers Contents Page Tape Wound Measuring and Protection Current Transformers 2 6 Split Core Current Transformers 7 9 3-in-1 Current
More information3/2-way Solenoid Valve, direct-acting, NC or NO
3/2-way Solenoid Valve, direct-acting, NC or NO Electrical connection cable plug, Form A With or without manual override as standard Threaded port and sub-base s Impulse optional Type 6014 can be combined
More informationRM4TG20 three-phase network control relay RM4-T - range 200..500 V
Characteristics three-phase network control relay RM4-T - range 200..500 V Complementary [Us] rated supply voltage Output contacts Setting accuracy of time delay Delay at power up Measuring cycle Marking
More informationC13 User Manual Document ID: 2CMC486004M0201 Revision: A 2013-06-19
C13 C13 Document ID: 2CMC486004M0201 2013-06-19 Disclaimer Copyrights Trademarks Contact The information in this document is subject to change without notice and should not be construed as a commitment
More informationMaximum Demand Control
Maximum Demand Control There are three terms that appear on the majority of electric company bills: Active energy consumption (kwh) Reactive energy consumption (kvarh) Maximum Demand Traditionally, utility
More informationRISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:
Application : RISH Master 3490 DS measures important electrical parameters of Utility (in normal mode) & Generators (in Power back up) in three phase and single phase Network & replaces the multiple analog
More informationPower Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1
Power Supply Unit, Primary Switched, Narrow Design MINI POWER provides: Extra narrow design with widths of 22.5 mm, 45 mm, and 67.5 mm (0.886, 1.772, and 2.657 in.) Global use due to a wide-range input
More informationSURGE PROTECTIVE DEVICES
SURGE PROTECTIVE DEVICES 1. INTRODUCTION In order to ensure safety of people, protection of equipment and, to a certain extent, continuity of supply, insulation co-ordination aims at reducing the likelihood
More informationMaterial: Weight: Bearing Life: Shaft Speed: Starting Torque: Mass Moment of Inertia: Shaft Loads:
Automation / Mini Type SCH32F Hollow Shaft Encoder - Ø 32 mm Hollow Bore: Ø 6 mm to Ø 3/8 inch Resolution up to 5000 ppr IP 65 (IP 50 for IDC connector option) Electrical Specifications Code: Resolution:
More informationRISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER
Application : The RISH CON - Hz transducer is used for frequency measurement. The output signal is proportional to measured frequency and is either load independent DC Current or load independent DC Voltage.
More informationTechnical data UNIBLOCK UBSF 180 625
Data TECHNICL DT Technical data UNIBLOCK UBSF 80 6 Output data Type UBSF 80 UBSF 0 UBSF 00 UBSF 6 Output power 80 kv 0 kv 00 kv 6 kv Output voltage 80/77 V 0/ V 0/ V 0/ V Output current 7 8 66 80 Power
More information38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A
38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A 38 SERIES Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit EMR Electromechanical
More informationSTEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: 2868567. DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase
Extract from the online catalog STEP-PS/1AC/12DC/1.5 Order No.: 2868567 DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase Commercial data EAN 4046356292924 Pack 1 pcs. Customs tariff
More information38 SERIES. Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.
38 Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A 38 Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit 6.2 mm wide EMR - DC, AC or AC/DC
More informationTape Wound, Split Core and Ebony Current Transformers
Tape Wound, Split Core and Ebony Current Transformers Table of contents Tape Wound Measuring and Protection Current Transformers 2 MR Series Measuring Range 3 PR Series Protection Range 4 Class PX Current
More informationSMS 4 / SMS 5 safety mat Product information
SMS 4 / SMS 5 safety mat Product information SMS 4 / SMS 5 safety mats Safety mats are used for the protection of man on machinery and plants with hazardous movements. Typical fields of application are,
More informationNF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals
Technical Datasheet 1SBC101433D0201 28/03/11 NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals NF(Z) contactor relays are used for switching auxiliary and control circuits.
More informationCURRENT TRANSFORMER MODEL 546 UL1015 #16 AWG LEAD WIRE, STANDARD LENGTH IS 24" 1 X
CURRENT TRANSFORMER MODEL 546 1.10" I.D. PAGE No 1-38 REV 15DEC00 TERMINAL OPTION LEAD WIRE OPTION 1.10 0 1.20 2.55 3.00 3.47 0.18 x 0.31 SLOT ( 2 PLACES) 8-32 BRASS STUD (2 PLACES) UL1015 #16 AWG LEAD
More informationPosition Transducers with Restoring Spring 10, 25, 50, 75, 100 mm TR, TRS Series
Position Transducers with Restoring Spring 10, 25, 50, 75, 100 mm TR, TRS Series Special features long life 100 x 10 6 movements outstanding linearity up to ±0.075% choice of plug or cable connection DIN
More informationR.C.C.B. s two-pole LEXIC
87045 LIMOGES Cedex Telephone : (+33) 05 55 06 87 87 Fax : (+ 33) 05 55 06 88 88 R.C.C.B. s two-pole LEXIC 089 06/09/10/11/12/15/16/17/18/ 27/28/29/30/35, CONTENTS PAGES 1. Electrical and mechanical characteristics...
More informationCatalog EN. Content Transformers for industrial applications
Catalog Ed. 2013 Catalog Content Transformers for industrial applications Technical information 5 Quick product selection card Single and three-phase transformers 6 Quick product selection card Single-phase
More information15 Series - Electronic step relay and dimmer. Features 15.91 15.51 15.81 SERIE
Series - Electronic step relay and dimmer SERIE Features.91.51.81 Electronic step relay and dimmer for control of lighting levels Suitable for incandescent and halogen lighting loads (with or without transformer
More informationDigital Pressure Measuring Instrument MDR480
Description The digital panel instrument MDR480 is designed to measure, display, and monitor pressures in industrial applications. The instrument is panel mounted with a front frame dimension of 96 mm
More informationElectronic overload relay EF19 and EF45
Data sheet Electronic overload relay EF19 and EF45 Electronic overload relays offer reliable protection in case of overload and phase-failure. They are the alternative to thermal overload relays. Motor
More informationHow To Choose A Transformer
Consider open loop MV network as an example source 1 source 2 NC NC NC or NO main MV switchboard A B Detail design of substation NC NC NC NO NC NC switchboard 1 switchboard 2 switchboard 3 MV MV MV LV
More informationVEO. V4PF480Y/277VSYTK02 Art.Nr.: 2104200. V4PF480Y/277VSYTK02P Art.Nr.: 2104210 TECHNICAL DATA
Monitoring of phase sequence and phase loss Monitoring of asymmetry Temperature monitoring (PTC) Supply voltage 208-480 V AC Supply circuit = measuring circuit 2 change-over contacts Width 45 mm Control
More informationRM35UA13MW. range 15..600 V. Main. Product or component type. Relay monitored parameters
Characteristics multifunction voltage control relay RM35-U - range 15..600 V Complementary Reset time Maximum switching voltage [Us] rated supply voltage Supply voltage limits Power consumption in W Main
More informationTechnical Description. Transistor D.C. Chopper Controller Type GS 24 S
Technical Description Transistor D.C. Chopper Controller Type GS 24 S Table of contents 1. Getting started guide 2. General information 2.1. Characteristics 2.2. Accessories 3. Information about the Machine
More informationSeries 6000 Torque measured metal bellow coupling
Properties Free of float metal bellow coupling with integrated torque measurement Non-contact measurement system, high robustness High torsional stiffness Limited torque of inertia Performance Measurement
More informationservo-controlled 3-WaY vacuum solenoid valves WiTH
servo-controlled 3-WaY vacuum solenoid s WiTH low absorption electric coil The 3-way vacuum solenoid s in this series feature two positions with pneumatically pilot-operated conical shutters. They can
More informationE-STOP relays, safety gate monitors
Unit features Safety features Gertebild ][Bildunterschrift_NOT_Sch.tuer_Licht Safety relay for monitoring E-STOP pushbuttons, safety gates and light beam devices Approvals Gertemerkmale Positive-guided
More informationElectronic timer CT-VBS.17+18 OFF-delayed without auxiliary voltage, for DC contactors Data sheet
Characteristics Single-function OFF-delay timer for DC contactors, without auxiliary voltage Width.5 mm CDC 5 6 F3 Approvals A culus E CCC CT-VBS a Circuit diagram b Marker label Marks a CE b C-Tick Order
More informationMOUNTING AND OPERATING INSTRUCTIONS
MOUNTING AND OPERATING INSTRUCTIONS CF 51/55 1. Delivery CF 51/55-1 calculator with battery (optionally with mains power supply) - 1 wall mounting bracket - package with material for sealing, screws, wall
More informationPositive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous
Safety relay for monitoring E-STOP pushbuttons. Approvals Unit features Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous 1 auxiliary contact (N/C), instantaneous Safe separation of
More information3/2- and 2/2-way cartridge valve type BVE
3/2- and 2/2-way cartridge valve type BVE for any flow direction, zero leakage, all ports pressure resistant Flow Q max = 70 lpm Perm. pressure p max = 400 bar Additional valves with same function: ' Type
More informationDRM75A 230V 20/100A DIN rail single phase two wire energy meter
DRM75A 230V 20/100A DIN rail single phase two wire energy meter 1.1 Safety instruction 1.2 Foreword 1.3 Performance criteria 1.4 Specifications 1.5 Basic errors 1.6 Description 1.7 Dimensions 1.8 Installation
More informationLENORD. +BAUER... automates motion. PowerDRIVE-Positioning GEL 6109 Compact positioning drive for installation situations with limited space
PowerDRIVE-Positioning GEL 6109 Compact positioning drive for installation situations with limited space LENORD +BAUER... automates motion. Technical information Version 2014-09 General The PowerDRIVE-Positioning
More informationLow voltage transformers
Low voltage transformers Open core CT SMART OBJECTS Time sensors Detect the signals, where they rise Low voltage transformers In the practice of industrial electrical measurement, some devices of the measurement
More informationThermal-Magnetic Circuit Breaker 3120-...-M1-..
Thermal-Magnetic Circuit Breaker -...-M-.. Description Single or two pole rocker switch/thermal-magnetic circuit breaker with trip-free mechanism (S-type TM CBE to EN 34). The addition of a magnetic tripping
More informationAPPENDIX A PIN-OUT OF RJ12 / RJ45 CONNECTORS. RJ12 connectors
APPENDIX APPENDIX A PIN-OUT OF RJ12 / RJ45 CONNECTORS RJ12 connectors Pin # 1 Signal Name Not Used 2 +TR Description + Data Line 3 +R Remote OFF Required or Remote OFF control 4 -TR 5 Not Used 6 RTN -
More informationAF09-30-22-.. / AF09Z-30-22-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals
Technical Datasheet 1SBC101403D0201 24/03/11 AF09-30-22-.. / AF09Z-30-22-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals AF09(Z) contactors are used for controlling power circuits
More informationHERZ-Thermal Actuators
HERZ-Thermal Actuators Data Sheet 7708-7990, Issue 1011 Dimensions in mm 1 7710 00 1 7710 01 1 7711 18 1 7710 80 1 7710 81 1 7711 80 1 7711 81 1 7990 00 1 7980 00 1 7708 11 1 7708 10 1 7708 23 1 7709 01
More informationUsing Current Transformers with the 78M661x
A Maxim Integrated Products Brand Using Current Transformers with the 78M661x APPLICATION NOTE AN_661x_021 April 2010 Introduction This application note describes using current transformers (CT) with the
More informationSensors. Sensors. All Cylinders. Specifications. Features: Features Type REED HALL EFFECT NPN or PNP. Ø8mm - 125mm
Specifications Features Type REED HALL EFFECT NPN or PNP Applicable Series Configurations Construction Materials Body Mounting Bracket Cable Characteristics Operating Temperature Accuracy All Cylinders
More informationHARDWARE MANUAL. Ixx24-A 1/20. Val Controls A/S Limfjordsvej 3 DK-6715 Esbjerg N Tel. +45 7547 0600 vc@valcontrols.com www.valcontrols.
HARDWARE MANUAL Ixx24-A 1/20 Table of contents 1 General... 3 1.1 Safety instructions... 3 1.2 Environment... 3 1.3 Mounting and dimension... 3 2 Communication... 4 2.1 Control loop AI0 and Transmitter
More informationPhone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
Product description Wide rated operational voltage 208 600 V AC Wide rated control supply voltage 100 250 V, 50/60 Hz Rated operational current 18 to 370 A Wide ambient temperature range, -25 to +60 ºC
More information0.84" x 2.00" Z-TRAUQ INC. Tel.: (450)226-6997 Fax: (450)226-5837 z-trauq@qc.aira.com SPLIT CORE CURRENT TRANSFORMER MODEL 1SP.
SPLIT CORE CURRENT MODEL 1SP 0.84" x 2.00" PAGE No 3-2 REV 18DEC00 UL 1015 LEAD WIRE, STANDARD LENGTH IS 36 E DIMENSIONS A = 0.84 MIN B = 2.00 MIN C = 3.31 MAX D = 3.09 MAX E = 0.61 MAX F = 0 MAX F C B
More information38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A
38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit EMR Electromechanical Relays
More informationH/L = Power supply. FN = Nominal Frequency. RN = Rated value of output burden. UN = Nominal input voltage. IN = Nominal input current.
Application : The transducer RISH CON - CA/CV (Fig.1) converts a sinusoidal AC Current or AC Voltage into a load independent DC Current or a load independent DC Voltage proportional to the measured value.
More informationElectric Rotary Actuator - On/Off or programmable control actuator
Electric Rotary Actuator - On/Off or programmable control actuator Direct mounting on quarter-turn valves Manual override standard Corrosion resistant Adjustable limit switches Multi-voltage version Type
More informationFeatures. Picture. Specifications
Type: for level measurement Order No.: see Table 1 / Page 4 Features Picture Two wire system Piezoresistive measuring element Output signal 4-20 ma Conformity error ±0.5 % FS or Standard DIN measuring
More informationProportional pressure regulators VPPE
Proportional pressure regulators VPPE Proportional pressure regulators VPPE Product range overview Function Version Pneumatic connection Proportional pressure regulator Nominal size for pressurisation/
More informationTop Microsystems Proprietary Specification P/N: W090015HK-XP 022410RB-082709V.A0 SPECIFICATION
SPECIFICATION High Quality Switching Wallmount Adapter Interchangeable AC Plugs 90-264VAC Input 13.5W 9VDC 1.5A Output P/N: W090015HK-XP ** Specification Approval** This specification (total 11 pages including
More informationPCB transformers. Short circuit proof PCB transformer VB. General Data. Advantages. Applications. Circuit diagram. Standards & 1 Certifications W v
Short circuit PCB transformer General Data Rated input 230 Vac Rated output 6-2 x 24 Vac Rated power 0.35-3.2 VA Insulation class B Maximum ambient temperature 70 C Efficiency up to 58 % Degree of protection
More informationAIR-AIR PRESSURE MULTIPLIER (BOOSTER)
AIR-AIR PRESSURE MULTIPLIER (BOOSTER) The air-air pressure multiplier, or booster, is an automatic device that compresses air to give an outlet pressure that is double the inlet pressure. It is normally
More information3-phase, bidirectional energy meter
Data sheet www.sbc-support.com 3-phase, bidirectional energy meter with S0 pulse output Bidirectional energy meter with S0-interface. The S0 interface is a hardware interface for the transmission of measured
More informationEMO T. Thermal actuator for heating, ventilation and air conditioning systems
EMO T Thermal actuator for heating, ventilation and air conditioning systems Pressurisation & Water Quality Balancing & Control Thermostatic Control ENGINEEING ADVANTAGE EMO T Description The EMO T thermal
More informationRY2 miniature industrial relays
6 RY2 Relays of general application For plug-in sockets, 35 mm rail mount acc. to PN-EN 60715 or on panel mounting Flat insert connectors - faston x 0,5 mm Recognitions, certifications, directives: RoHS,
More informationReaction Torque Sensor
Force 1 1 N m up to 1 000 1 000 N m Type 9329A 9389A These easy to install piezoelectric reaction torque sensors are particularly suitable for measuring rapidly changing torques at non-rotating shafts.
More information