Current transformers (CT) & Shunts
|
|
- Edgar Cox
- 7 years ago
- Views:
Transcription
1 Current transformers (CT) & Shunts Genreal overview LV CURRENT TRANSFORMERS Product selection guide Standard industrial transformers?????? TCR - TCRO range NEW Current summation JVM 0 9 TCR usbar primary TCR Cable/busbar primary TCR Wound primary TCRO Split core 9 Associated Products PRTC CT protection unit 0
2 Product selection guide Energy metering transformers 0 Product selection guide????????? 0 0 TRANSDUCERS 0 TRANSFORMERS SHEL range CONTROLLING AND RELAYS SHMI range 9 SHMO RANGE DIN rail mounting APPENDIX Class ENERGY METERS POWER MONITORS 0 NETWORK ANALYZERS 00 JVS usbar primary ANALOGUE NEW JVS Cable/busbar primary DIGITAL????????? JVS range SELECTION GUIDE INFO & ADVICE 90
3 Product selection guide Current transformers (CT) SELECTING A STANDARD INDUSTRIAL CURRENT >>> Selecting an energy metering transformer : page TCR 0 TCR TCR TCR TCR TCR TCR TCR TCR Wound primary (connection) x Ø M mm aperture wire Cable primary (mm) Ø 0 Ø Ø Ø Ø Ø usbar primary (m) x 0 0 x 0 x 0 0 x x 0 x 0 x 0 x x 0 x x x x 0 x 0 0 x 0 0 x 0 0 x 0 A 0 A A 0 A A 0 A 0 A A A A 00 A A A 00 A A 00 A 00 A 0 A 0 A A 00 A 000 A 00 A 0 A 000 A 0 A 000 A 000 A 00 A Advantages TCR primary 9 Combining a high level of accuracy and compact design TCR Cable/busbar primary 9 Come in a wide range of primaries Mounting accessories supplied as standard Secondary A or A as standard Secondary A as standard Secondary A optional Secondary A only
4 TRANSFORMER TCR usbar primary 9 TCRO Split core 9 ENERGY METERS POWER MONITORS NETWORK ANALYZERS TCR 0 TCR 90 TCR 00 TCRO 00 TCRO 0 TCRO 00 TCRO 00 TCRO 0 00 x 0 00 x 0 x 0 x 0 x 0 0 x 0 0 x 0 0 x ANALOGUE DIGITAL TRANSDUCERS TRANSFORMERS CONTROLLING AND RELAYS APPENDIX Complete products for 00 and mm busbar type A wide range adapted to most primaries. Installation w/o disconnection INFO & ADVICE RANGE INFO 90 9
5 Product selection guide Current transformers (CT) & shunts SELECTING A CURRENT TRANSFORMER FOR ENERGY METERING JVS Cable/busbar primary JVS JVS JVS 0 JVS JVS 0 JVS JVS Cable primary (mm) Ø Ø Ø Ø usbar primary (mm) 0 x 0 0 x x 0 x 00 x 0 00 x 0 x x 0 x x x 0 0 x 0 0 x 0 0 x 0 00 A A 00 A A 00 A 00 A 0 A 0 A A 00 A 000 A 00 A 0 A 000 A 0 A 000 A 000 A 00 A Advantages High-precision range with very little phase shift, particularly adapted to electronic measurement instruments and ideal for energy metering. 0 JVS usbar primary 0 Secondary A as standard Secondary A as standard with individual test certificate Secondary A with or without individual test certificate (available on request)
6 Info & advice Current transformers (CT) & shunts KEEPING UP WITH CURR TRANSFORMERS Current transformers supply low voltage measuring instruments and isolate them from the network. They supply a standard current to the secondary that is proportional to the primary current. SELECTING A TRANSFORMER MOUNTING TYPE AND PRIMARY NOMINAL CURRENT The choice depends on the types of bars or cables and the nominal current on your installation. WOUND PRIMARY for currents less than A ACCURACY CLASS The accuracy class is defined according to the errors generated by on each element of the measurement line. The accuracy class of the CT should be less than or equal to that of the measuring instrument it supplies, especially where energy metering is concerned, where the accuracy impacts directly on the billing. PERMITTED POWER CALE PRIMARY for currents between 0 and 0 A USAR PRIMARY for currents between to 00 A This is the apparent power (in VA) that the CT must supply to the secondary in order to maintain its accuracy class. It is necessary to add the power absorbed by the measuring instruments ay be quite important. It is necessary to choose a CT whose power is slightly greater than the result of this calculation while avoiding too great a safety margin. This power, even though it may seem comparatively low, has a direct impact on the specifications of the CT. Moreover, the accuracy class is only guaranted for a real load between % and 00 % of the nominal power (between % and 00 % for class ). A CT oversized in VA will be more expensive. SPLIT CORE PRIMARY for easy connection to an existing installation using a busbar or cable primary Power (VA) in class Weight 00 A A A 0 0. A A Dissipated power per metre double line Cross-section Secondary A Secondary A. mm 0. VA 0.0 VA. mm 0. VA 0.0 VA mm 0. VA VA mm 0. VA 0.00 VA SECONDARY: OR A A secondary current of A causes less loss on the line than a A current. A secondary current of A requires less winding for the CT, and so a less expensive and lighter CT than with a current of A. Reference Secondary A Secondary A 00 A A A A A 9 9 0
7 ENT CHANGES... CONNECTING YOUR CT supply use Secondary It is important to always install the transformer in the right direction, especially on three-phase networks, so as not to invert the phase shift between the current and the voltage on one or more of the phases. The shunts create a standard voltage drop that can be processed by measuring instruments. Though essentially used on direct currents, they can also be used on alternative currents. HOW TO INSTALL A SHUNT? Avoid overheating A shunt emits heat that must be evacuated in order to maintain the accuracy class. Up to 00 A the heat evacuation is by natural convection. eyond this, natural convection must be associated with thermal dissipation in the conductors on which it is mounted. Natural convection is best achieved when the shunt is in the horizontal position, with the blades oriented vertically. Calculation of the heat evacuated is carried out by the contractor, especially evacuation by linking bars (size, disposition, number). For use on direct currents, it is recommended not to go beyond 0 % of the nominal current of the shunt and to ensure that the temperature of the latter does not exceed /K: power supply side C (heating plus ambient temperature). For high currents, forced convection is compulsory. Limit derivation currents It is possible to connect one or more receivers to one shunt on condition that the derivation current or the sum of the derivation current is relatively small compared to the nominal rating. You must take into account the additional voltage drop introduced by the length of the derivation wires. The derivation current generally accepted to remain in the accuracy class is ma. /L: installation side FOCUS How to know whether the accuracy class of a CT is respected? If on a CT primary, the current is between 00 % and 0 % of the nominal current, the stated class is respected. In case of a lower current, the IEC standard 0- specifies the tolerances accepted. This tolerance is greater the smaller the measured current is with respect to the rating. The financial importance of selecting an accuracy class adapted to your CT For a consumption of 000 MWh/year and a cost of 0,0 /kwh CT class : ±0 000 kwh = ± 000 CT class 0.: ± 000 kwh = ± 000 CT class 0.S: ± 0 kwh = ± 0 This calculation takes into account neither the class of the measuring instruments, nor loss occurring on the network cables. CT safety rules You must never open the secondary circuit of a CT supplied on the primary. The very high voltage created may cause bodily harm or irreparable damage to the transformer. efore working on the secondary of a CT, it must be short circuited. When a CT is not in use (secondary open) the secondary must be short-circuited before powering up the system. Installation of CT protection unit (PRTC type) allows safe conditions in case of maintenance on instruments connected on a CT secondary circuit. Further remarks concerning shunts They are manufactured using a coppermagnesium-nickel alloy, offering long term stability and a low temperature coefficient. The shunt must be mounted on an insulated support in compliance with the usual rules applicable to current conductors (in LV see NFC 00). An extremity may be grounded depending on use. QUIZZ Test your knowledge: An oversized CT is: inefficient dangerous outside the class A CT secondary current of A is more expensive: true false sometimes Which of these ranges enables you to obtain the least energy metering error? TCR JVS GENERAL OVERVIEW RANGE INFO 9 ENERGY METERS POWER MONITORS NETWORK ANALYZERS ANALOGUE DIGITAL TRANSDUCERS TRANSFORMERS CONTROLLING AND RELAYS APPENDIX To check your answers visit our site:
8 Current transformers (CT) TCR RANGE Current transformers designed to supply analogue or digital measuring instruments. Accuracy class 0.// TCR wound primary Outputs on split terminals enabling short-circuiting of the secondary current (M or cage for mm wire) TCR Cable/busbar primary Standard industrial transformers Supplied with bar clamp fitting accessories DIN rail mounting using supplied clip on adapters for TCR - - TCR usbar primary Mounting on cabinet base using removable screw-on clips TCRO Split core primary PRODUCT ADVANTAGES EXTENDED RANGE: primary currents from to 00 A and A or A secondary currents DIN RAIL MOUNTING: on plate mounting or fixed around busbars COMPACT DESIGN General specifications Reference standards: EN 0- (ex CEI ) Maximum network voltage: 0 Vac Dielectric test voltage: kv/ Hz/mn Frequency response: / Hz Short-circuit thermal current (Ith): In - second Dynamic current (Idyn):. Ith Safety factor: < Operating conditions Temperature: -0 C to + C Relative humidity: < 90 % Protection Protection rating: IP (terminal covers supplied) Dry winding with self-extinguishing AS covering (UL 9VO) E F C CT Mounting A E F C Gmax A D Dimension Model A TCR 0 Gmax TCR - D TCR TCR TCR TCR 9 TCR 9 TCR.. TCR 09 TCR 0 9 TCR 90 TCR 00 C D Mounting accessories E F G DIN rail Surface mounting busbar clamp Model fittings fittings TCR TCR 9 00 TCR TCR TCR TCR TCR TCR TCR TCR 0 TCR 90 TCR 00 Standard accessories Accessories on request
9 TCR Wound primary TCR 0 TCR ENERGY METERS POWER MONITORS 0, x mm aperture TCR 0 0, 0, 0 Ø M et M 0 0 M M 0 0 M M TCR TCR : mm wire Secondary: mm wire, 0 0 NETWORK ANALYZERS ANALOGUE 0, 0, 0, Ø, 0 A M0X Ø, 0 A M0X A A A A A A A A A A A Ø,, A A. 0. A A. 0. A A A. 0. A. 0. A. 0. PRIMAIRE SECONDAIRE DIN (EN 0) FIXATION A A. 0. A A. 0. A A A. 0. A. 0. DIGITAL TRANSDUCERS TRANSFORMERS CONTROLLING AND RELAYS T O O R D E R Secondary A Secondary A A A 9 90 A A 9 90 A A A 9 90 A A 9 90 A A 90 A 90 A 90 Secondary A Secondary A A A 9 90 A A 9 90 A A A 9 90 A A 9 90 Secondary A Secondary A A A 9 90 A A 9 90 A A A 9 90 A APPENDIX Associated products Mounting accessories 9 PRTC CT protection unit 0 SELECTION GUIDE INFO & ADVICE RANGE INFO RANGE CONTD
10 0, 9 0, Standard industrial transformers Current transformers (CT),,,, 9 0 TCR RANGE Cable Ø 0 mm ar: x 0 mm - 0 x 0 mm x mm, 9, 0, 0,, 9 9,,, 9 Power (VA) class 0, Weight 0 A A A A A A.. 0. A A A.. 0., TCR 0, TCR 0,,, 9 Cable Ø mm ar: 0 x mm - x mm 0 x 0 mm 0 9, 9,, 0, TCR Cable/busbar primary 0, 0,, 9, 00 A A A A A A A A A TCR TCR Cable Ø mm ar: 0 x 0 mm - x mm 0 x 0 mm A A A A A A A A A Secondary A Secondary A 0 A 9 90 A A 9 90 A A 9 90 A 9 90 A A A 9 90 T O O R D E R Secondary A Secondary A 00 A 9 90 A 9 90 A A A A A A A 9 90 Secondary A Secondary A 00 A 9 90 A 9 90 A A A A A A A 9 90 Associated products PRTC CT protection unit 0
11 TCR Cable/busbar primary ENERGY METERS POWER MONITORS TCR TCR TCR TCR NETWORK ANALYZERS Cable Ø mm ar: 0 x mm - 0 x mm 0 x 0 mm.. Cable Ø mm ar: x 0 mm - x mm,, 9 Cable Ø mm ar: x mm - x mm 0 x 0 mm. 0 M. ANALOGUE.. 0., ,,.., 9 0, 0, DIGITAL. 0,, 0, Power (VA), class Weight 00 A A A A.. 0. A A A A A A A A A A 0 0. A A A A A T O O R D E R 00 A A A A A A A A A A A M TRANSDUCERS TRANSFORMERS CONTROLLING AND RELAYS APPENDIX Secondary A Secondary A 00 A 9 90 A 9 90 A A A A A A A 9 90 A A 9 90 Secondary A Secondary A 00 A A A 9 90 A A A A A 9 90 Secondary A Secondary A 00 A A A 9 90 A A A A A A A A 9 90 Associated products PRTC CT protection unit 0 SELECTION GUIDE INFO & ADVICE RANGE INFO RANGE CONTD
12 Standard industrial transformers Current transformers (CT) TCR RANGE ar 00 x 0 mm,, 9 0 TCR 00 TCR 0 0 A A A A A A ar 00 x 0 mm 0, 90 TCR Cable/busbar primary 0 0 A A A A A TCR 90 TCR 00 ar x mm A A A A A A A A 0 0. T O O R D E R Secondary A Secondary A A A A A A A 9 90 Associated products PRTC CT protection unit 0 Secondary A Secondary A 0 A A A A A Secondary A Secondary A 000 A A A A A A A A 90
13 TCRO RANGE Current transformers designed for insertion on electrical installations without disconnection conductor ENERGY METERS POWER MONITORS TCRO Cable/busbar primary Captive sealable terminal covers. Split output terminals enabling risk-free short-circuiting of the secondary current (cage for mm wire) NETWORK ANALYZERS ar clamp fitting ANALOGUE DIGITAL Plate mounting fitting TRANSDUCERS PRODUCT ADVANTAGES PRIMARY from 00 to 00 A and wide choice of primary options FULLY OPENING primary TRANSFORMERS C F General specifications Reference standard: EN 0- (ex CEI ) Maximum network voltage: 0 Vac Dielectric test voltage: kv/ Hz/mn Frequency response: / Hz E Short-circuit thermal current (Ith): In - second Dynamic current (Idyn):, Ith Safety factor:< Operating conditions: Temperature: - 0 C to + C Relative humidity: < 90 % Protection: Protection rating: IP (terminal covers supplied) Dry winding with self-extinguishing AS covering (UL 9 VO) CONTROLLING AND RELAYS APPENDIX A Gmax D CT Mounting Mounting accessories F Gmax E D Dimensions Model A C D E F G TCRO TCRO TCRO TCRO TCRO 0 0 Model TCRO 00 TCRO 0 TCRO 00 TCRO 00 TCRO 0 Cabinet base fittings busbar clamp Standard accessories SELECTION GUIDE INFO & ADVICE RANGE INFO RANGE CONTD
14 Standard industrial transformers Current transformers (CT) TCRO RANGE ar 0 x 0 mm TCRO (kg) 00 A A A A Associated products 9 9 TCRO ar x 0 mm 0 0 TCRO 0 TCRO (kg) A A A A A A A T O O R D E R TCRO Split core ar 0 x 0 mm A A A A A A A Secondary A Secondary A Secondary A 00 A 90 0 A 90 A 90 A A A A A A A 90 0 A 90 0 A 90 0 A 90 0 A A A A A 90 On request: secondary A On request: secondary A On request: secondary A PRTC CT protection unit 0
15 TCRO split core ENERGY METERS POWER MONITORS TCR 00 TCRO TCRO 00 0 TCRO 0 NETWORK ANALYZERS ar 0 x 0 mm ar 0 x mm ANALOGUE 0 0 DIGITAL TRANSDUCERS Power (VA) class Weight 0 A A A A A.0 0 A 0.0 Power (VA) class Weight 000 A A A 0. 0 A A A A 0 0. TRANSFORMERS CONTROLLING AND RELAYS T O O R D E R APPENDIX Secondary A 0 A 90 0 A A A A 90 0 A 90 Associated products PRTC CT protection unit 0 On request: secondary A Secondary A 000 A 90 0 A A 90 0 A A A A 90 On request: secondary A SELECTION GUIDE INFO & ADVICE RANGE INFO
16 Current transformers (CT) JVS RANGE 0, class CTs for the supply of electronic measuring and metering equipment according to IEC : power monitors, digital transducers, etc. Split output terminals enabling risk-free short-circuiting of the secondary current (cage for mm wire) JVS usbar primary 0 Energy metering transformers Captive sealable terminal covers JVS Cable/busbar primary 0 Cabinet base fitting (or directly on busbar primary) PRODUCT ADVANTAGES WIDE CHOICE OF PRIMARIES from 00 to 0 A ACCURACY CLASS: 0. for high-performance applications General specifications F C Reference standard: EN 0- (ex CEI ) Maximum network voltage: 0 Vac Dielectric test voltage: kv/ Hz/mn Frequency response: / Hz Short-circuit thermal current E - second (Ith): In Dynamic current (Idyn):. Ith Safety factor: < Operating conditions: Temperature: -0 C to + C Relative humidity: < 90 % Protection: Protection rating: IP (terminal covers supplied) Dry winding with self-extinguishing AS covering (UL 9 VO) CT Mounting Mounting accessories Gmax A E F C Gmax A D Model JVS JVS JVS 0 JVS JVS 0 JVS JVS D Dimensions A C D E F G Model JVS JVS JVS 0 JVS JVS 0 JVS JVS Cabinet base fittings busbar clamp Standard accessories
17 JVS Cable/busbar primary ENERGY METERS POWER MONITORS JVS JVS JVS NETWORK ANALYZERS ANALOGUE Cable ø mm ar: 0 x 0 mm x mm 0 x 0 mm 0. Power (VA) Weight in class 0. S (kg) 00 A 0. A A. 0. A A A Cable ø mm ar: 0 x mm 0 x mm 0 x 0 mm Power (VA) Weight in class 0. S (kg) A A. 0. A A A 0. 0 A 0. 0 A 0. A A. 0. DIGITAL TRANSDUCERS TRANSFORMERS CONTROLLING AND RELAYS Secondary A 00 A JVS 00/ A JVS / 00 A JVS 00/ A JVS / 00 A JVS 00/ 00 A JVS 00/ Supplied with individual test certificate T O O R D E R Secondary A A JVS 00/ 00 A JVS 00/ A JVS / 00 A JVS 00/ 00 A JVS 00/ 0 A JVS 0/ 0 A JVS 0/ A JVS / 00 A JVS 00/ APPENDIX Associated products PRTC CT protection unit 0 SELECTION GUIDE INFO & ADVICE RANGE INFO RANGE CONTD
18 ,,,, Energy metering transformers Current transformers (CT) 0, 9, 0. JVS RANGE,,,, JVS 0 JVS 0 0, 9 Cable ø mm ar: x 0 mm x mm Power (VA) Weight in class 0. S (kg) 0 A 0. A A A A A JVS Cable/busbar primary JVS Cable ø mm ar: x mm x 0 mm 0 x 0 mm Power (VA) Weight in class 0. S (kg) 000 A A A A A A 0 0. M M 0 T O O R D E R.. 0. Secondary A 0 A JVS0 0/ A JVS0 / 00 A JVS0 00/ 000 A JVS0 000/ 00 A JVS0 00/ 0 A JVS0 0/ Secondary A 000 A JVS 000/ 00 A JVS 00/ 0 A JVS 0/ 000 A JVS 000/ 0 A JVS 0/ 000 A JVS 000/. 0 Supplied with individual test certificate Associated products PRTC CT protection unit 0
19 JVS JVS JVS busbar primary ENERGY METERS POWER MONITORS JVS 0 JVS JVS NETWORK ANALYZERS ar: 00 x 0 mm 9 ar: 00 x 0 mm ar: x mm ANALOGUE DIGITAL TRANSDUCERS Power (VA) Weight in class 0. S (kg) 000 A A 0. 0 A A 0 0. Power (VA) Weight in class 0. S (kg) 0 A A A A A T O O R D E R Power (VA) Weight in class 0. S (kg) 000 A A A A A A A 0. TRANSFORMERS CONTROLLING AND RELAYS APPENDIX Secondary A 000 A JVS0-000/ 00 A JVS0-00/ 0 A JVS0-0/ 000 A JVS0-000/ Supplied with individual test certificate Secondary A 0 A JVS-0/ 000 A JVS-000/ 0 A JVS-0/ 000 A JVS-000/ 000 A JVS-000/ Secondary A 000 A JVS-000/ 0 A JVS-0/ 000 A JVS-000/ 0 A JVS-0/ 000 A JVS-000/ 000 A JVS-000/ 00 A JVS-00/ Associated products PRTC CT protection unit 0 SELECTION GUIDE INFO & ADVICE RANGE INFO
20 Current summation Current transformers (CT) JVM CURRENT SUMMATION: JVM CT designed for adding or substract instantaneous values from the secondary of or current transformers. Used to supply measuring or metering instruments on installations with several departure and arrival points. PRODUCT ADVANTAGES Sealable cover. Terminal connections: M; secondary slots for double connections; primary side connections. Mounting on symmetric slide rail or fitting to cabinet base. COMPACT DESIGN FITTED for surface or DIN rail mounting General specifications Reference standard: EN 0- (ex CEI ) Maximum network voltage: 0 Vac Dielectric test voltage: kv/ Hz/mn Frequency response: / Hz Short-circuit thermal current (Ith): 0 In - second Dynamic current (Idyn):. Ith Safety factor:< Internal power: VA Operating conditions: Temperature: - C to + C Relative humidity: 9 % at 0 C Protection: Protection rating: IP 0 (module casing) and IP 0 (terminals) Dry winding with self-extinguishing AS covering (UL 9 VO) Cabinet accessories Model CT slide CT slide CT slide rail mounting rail mounting rail mounting JVM ACCE ACCE ACCE fittings (M) Scalable cover A A TO ORDER Secondary A + A JVMA ++ A JVMA Sealable cover ACCE M
Measurement and Instrumentation
POWER QUALITY ENERGY PERFORMANCE Measurement and Instrumentation Transformers and shunts Transformers Overview of ranges Selection guide Info & advice Standard industrial transformers TCR TCRO ranges Adaptable
More informationkeep your measure under control
INSTRUMENTACIÓN INDUSTRIAL ZURC, S.A. keep your measure under control CURRENT For measuring instruments. Mounted in selfexinguishing, plastic, strengthened cases. Isolation voltage V Made as per UNEEN
More informationLOW-VOLTAGE CURRENT TRANSFORMERS
LOWVOLTAGE CURRENT TRANSFORMERS 5 A Power network meters ND0 and ND type. N4Z and N5Z Tel: (+48 68) 45 75 39; 45 75 305; 45 75 3; 45 75 368; email: export@lumel.com.pl ul. Słubicka 657 Zielona Góra CONTENTS
More informationBETA Protecting SITOR Semiconductor Fuses
BETA Protecting SITOR Semiconductor Fuses /2 Product overview /3 /17 SITOR, cylindrical fuse design /22 SILIZED, NEOZED and DIAZED design Siemens ET B1 /2008 Product overview Overview Devices Page Field
More informationTape Wound, Split Core and Ebony Current Transformers
Tape Wound, Split Core and Ebony Current Transformers Current Transformers Contents Page Tape Wound Measuring and Protection Current Transformers 2 6 Split Core Current Transformers 7 9 3-in-1 Current
More informationTape Wound, Split Core and Ebony Current Transformers
Tape Wound, Split Core and Ebony Current Transformers Table of contents Tape Wound Measuring and Protection Current Transformers 2 MR Series Measuring Range 3 PR Series Protection Range 4 Class PX Current
More informationRM17TE 183...528 V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC
Characteristics multifunction control relay RM17-TE - range 183..528 V AC Complementary Reset time Maximum switching voltage Minimum switching current Maximum switching current [Us] rated supply voltage
More informationEnhanced Quality with a Touch of Style
Rudolf Current Transformer Enhanced Quality with a Touch of Style Current Transformer Enhanced Quality with a Touch of Style New Products Rudolf launched our new encapsulated current transformer. Portraying
More informationVario-Series Accessories
Accessories and spare parts for GMW analogue panel meters and controllers Current Transformers pages 2-9 Shunt Resistors 10-11 Voltage Dividers 12 Power supply for indicator/controllers 13 Blanking Plates
More informationA project to optimise quality and energy efficiency must include metering
EMDX 3 : Energy Metering A project to optimise quality and energy efficiency must include metering Metering upstream identifies the critical points and ensures optimum targeting of the actions to be taken,
More informationMeasurement devices Accessories for analogue and digital instruments
Accessories for analogue and digital instruments 1 2CSC96F0001 Current transformers Used to transform primary currents (max. 6000 A) into.../5 A and.../1 A low secondary currents indirectly supplying power
More informationRM35UA13MW. range 15..600 V. Main. Product or component type. Relay monitored parameters
Characteristics multifunction voltage control relay RM35-U - range 15..600 V Complementary Reset time Maximum switching voltage [Us] rated supply voltage Supply voltage limits Power consumption in W Main
More informationRM4TG20 three-phase network control relay RM4-T - range 200..500 V
Characteristics three-phase network control relay RM4-T - range 200..500 V Complementary [Us] rated supply voltage Output contacts Setting accuracy of time delay Delay at power up Measuring cycle Marking
More informationCurrent valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw
4 937 DESIO Current valve for AC 24 V pulse/pause control of electrical loads up to 30 kw SEA45.1 Use The current valve is used for the control of electric heating elements in heating, ventilation and
More informationQuick Connect. quick - simple - efficient. www.g-mw.de
Quick Connect quick - simple - efficient www.g-mw.de Phone: +49 9103 7129-0 Fax: +49 9103 7129-207 Innovative connection technology to plug three single-phase current transformers to multifunctional power
More informationActuator-Sensor-Interface
Selection and ordering data Design Order No. Price Pack 3RX9 307-0AA00 3RX9 307-1AA00 4FD5 213-0AA10-1A 3RX9 305-1AA00 3RX9 306-1AA00 Single output IP 65 current 2.4 A Rated input voltage DC 24 V current
More informationRISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER
Application : The RISH CON - Hz transducer is used for frequency measurement. The output signal is proportional to measured frequency and is either load independent DC Current or load independent DC Voltage.
More informationPower Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1
Power Supply Unit, Primary Switched, Narrow Design MINI POWER provides: Extra narrow design with widths of 22.5 mm, 45 mm, and 67.5 mm (0.886, 1.772, and 2.657 in.) Global use due to a wide-range input
More informationMedium-voltage transformers
Medium-voltage transformers We make energy measurable and take care of your future www.mbs-ag.com Page 2 E-Mail: info@mbs-ag.com Web: www.mbs-ag.com Contents Current transformers Technical characteristics
More informationPower Meter Series 700
PowerLogic power-monitoring units Power Meter Series 700 Technical data sheet 2007 Functions and characteristics E90463 The PowerLogic Power Meter Series 700 offers all the measurement capabilities required
More informationPower Supplies 3. SDN-P DIN Rail Series
SDN-P DIN Rail Series The SDN DIN Rail power supplies provide industry leading performance. Sag Immunity, transient suppression and noise tolerant, the SDN series ensures compatibility in demanding applications.
More informationCT Current transformers Ideal for measuring. Designed to create efficiency.
CT Current transformers Ideal for measuring. Designed to create efficiency. CT Current transformers Optimize consumptions. Improve the efficiency. Energy efficiency, minimized costs and high system availability
More informationPCB transformers. Short circuit proof PCB transformer VB. General Data. Advantages. Applications. Circuit diagram. Standards & 1 Certifications W v
Short circuit PCB transformer General Data Rated input 230 Vac Rated output 6-2 x 24 Vac Rated power 0.35-3.2 VA Insulation class B Maximum ambient temperature 70 C Efficiency up to 58 % Degree of protection
More informationRedundancy Module QUINT-DIODE/40
Redundancy Module QUT DIODE provides: 00% decoupling of power supplies connected in parallel Can be installed in potentially explosive areas Load currents up to 60 A supported Easy assembly by snapping
More informationSINEAX U553 Transducer for AC Voltage
With power supply RMS value measurement Carrying rail housing P/0 Application he transducer SINEAX U55 (Fig. ) converts a sinusoidal or a distorted AC voltage into a load independent DC current or a load
More informationSURGE PROTECTIVE DEVICES
SURGE PROTECTIVE DEVICES 1. INTRODUCTION In order to ensure safety of people, protection of equipment and, to a certain extent, continuity of supply, insulation co-ordination aims at reducing the likelihood
More informationThermistor motor protection
Thermistor motor protection CM-E Range Thermistor motor protection Thermistor motor protection relays Benefits and advantages Selection table Operating principle and fields of application for thermistor
More informationControl Devices Catalogue. Control Devices. Preferred and Standard Products
Control Devices Catalogue Control Devices Preferred and Standard Products KOP.J Timer Electronic 22.5 mm Characteristics Mounting KOP.J 22.5 mm mono or multifunction high immunity to interference surface
More informationCurrent Transformers
Tyco Electronics Corporation Crompton Instruments 1610 Cobb International Parkway, Unit #4 Kennesaw, GA 30152 Tel. 770-425-8903 Fax. 770-423-7194 Current Transformers Current transformers (CT's) provide
More informationR.C.C.B. s two-pole LEXIC
87045 LIMOGES Cedex Telephone : (+33) 05 55 06 87 87 Fax : (+ 33) 05 55 06 88 88 R.C.C.B. s two-pole LEXIC 089 06/09/10/11/12/15/16/17/18/ 27/28/29/30/35, CONTENTS PAGES 1. Electrical and mechanical characteristics...
More informationKOLMA and IHDA Indoor type Cable Current Transformers Catalogue ABB Power Distribution ABB Transmit 1 KKOLMA 1 GB
KOLMA and IHDA Indoor type Cable Current Transformers Catalogue ABB Power Distribution ABB Transmit 1 KKOLMA 1 GB KOLMA and IHDA Indoor Type Cable Current Transformers Index Description... 3 Technical
More informationProduct and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.
Product and Applications Description The power supply units N 125/x2 can supply DC 24 V power from an additional pair of terminals (yellowwhite). This DC 24 V output voltage can be used to power e.g. an
More informationVIBRATION MONITORING OF FANS INSTALLED IN ROAD TUNNELS
VIBRATION MONITORING OF FANS INSTALLED IN ROAD TUNNELS CEMB SPA Via Risorgimento, 9 Mandello del Lario (Lc), Italy stm@cemb.com www.cemb.com INSTRUMENT FOR MONITORING VIBRATIONS OF FANS INSTALLED IN ROAD
More informationThyristor-controlled power supplies and battery chargers
Thyristor-controlled power supplies and battery chargers Input voltage: 115 / 230 VAC, single phase, 50 / 60 Hz or 208 / 400 / 480 VAC, three phases, 50 / 60 Hz Output voltage: 12 / 24 / 48 / 60 / 72 /
More informationPHOENIX CONTACT - 2012-12-14. Features
Electronic monitoring relay for phase sequence, phase failure, and asymmetry monitoring Data sheet 101748_en_03 1 Description PHOEIX COTACT - 2012-12-14 Features Increasingly higher demands are being placed
More informationYour Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592. * see variants. Applications.
Safety Technique SAFEMASTER Emergency Stop Module BG 5924, IP 5924 Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592 BG 5924 IP 5924 Product Description
More informationVEO. V4PF480Y/277VSYTK02 Art.Nr.: 2104200. V4PF480Y/277VSYTK02P Art.Nr.: 2104210 TECHNICAL DATA
Monitoring of phase sequence and phase loss Monitoring of asymmetry Temperature monitoring (PTC) Supply voltage 208-480 V AC Supply circuit = measuring circuit 2 change-over contacts Width 45 mm Control
More informationCurrent transformer selection guide
The selection of a current transformer is a simple task. There are four phases in the selection procedure. Current transformer selection guide KEEP IN MIND efine customer requirements based on the primary
More informationH/L = Power supply. FN = Nominal Frequency. RN = Rated value of output burden. UN = Nominal input voltage. IN = Nominal input current.
Application : The transducer RISH CON - CA/CV (Fig.1) converts a sinusoidal AC Current or AC Voltage into a load independent DC Current or a load independent DC Voltage proportional to the measured value.
More informationGuidance for upgrading to GB4943.1-2011 (IEC 60950-1: 2005, MOD)
Guidance for upgrading to GB4943.1-2011 (IEC 60950-1: 2005, MOD) Note: This guidance document is a translation of official Chinese document which is issued by CQC (China Quality Certification Center) on
More informationCURRENT TRANSFORMERS INSTALLATION GUIDE
CURRENT TRANSFORMERS INSTALLATION GUIDE Information contained within this document is subject to change without notice and does not represent a commitment on the part of PRI Ltd or its agents. E&OE. Copyright
More informationMINI MCR-SL-R-UI(-SP)
Resistance/potiposition transducer INTERFACE Data Sheet 0807_en_05 Description PHOENIX CONTACT - 0/008 Features The slim MINI MCR-SL-R-UI... potiposition transducer has a width of only 6. mm and converts
More informationABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories
2CDC 251 014 F0t09 Features Monitoring of three-phase mains for grid feeding Type-tested in accordance with DIN V VDE V 0126-1-1: February 2006 Neutral conductor connection configurable Can also be used
More informationVoltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages
Data sheet Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages The CM-ESS.2 is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of
More informationTechnical data UNIBLOCK UBSF 180 625
Data TECHNICL DT Technical data UNIBLOCK UBSF 80 6 Output data Type UBSF 80 UBSF 0 UBSF 00 UBSF 6 Output power 80 kv 0 kv 00 kv 6 kv Output voltage 80/77 V 0/ V 0/ V 0/ V Output current 7 8 66 80 Power
More informationElectronic overload relay EF19 and EF45
Data sheet Electronic overload relay EF19 and EF45 Electronic overload relays offer reliable protection in case of overload and phase-failure. They are the alternative to thermal overload relays. Motor
More informationCURRENT TRANSFORMER MODEL 546 UL1015 #16 AWG LEAD WIRE, STANDARD LENGTH IS 24" 1 X
CURRENT TRANSFORMER MODEL 546 1.10" I.D. PAGE No 1-38 REV 15DEC00 TERMINAL OPTION LEAD WIRE OPTION 1.10 0 1.20 2.55 3.00 3.47 0.18 x 0.31 SLOT ( 2 PLACES) 8-32 BRASS STUD (2 PLACES) UL1015 #16 AWG LEAD
More informationUsing Current Transformers with the 78M661x
A Maxim Integrated Products Brand Using Current Transformers with the 78M661x APPLICATION NOTE AN_661x_021 April 2010 Introduction This application note describes using current transformers (CT) with the
More informationProblem / Solution. The problem:
Problem / Solution Solar Photovoltaic (PV) technology has shown significant development in recent years and this has led to many UK homeowners investing in Solar PV installations. Solar electricity is
More informationVoltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages
Data sheet Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages The CM-ESS.2 is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of
More informationDigital Energy ITI. Instrument Transformer Basic Technical Information and Application
g Digital Energy ITI Instrument Transformer Basic Technical Information and Application Table of Contents DEFINITIONS AND FUNCTIONS CONSTRUCTION FEATURES MAGNETIC CIRCUITS RATING AND RATIO CURRENT TRANSFORMER
More informationPosition Transducers with Restoring Spring 10, 25, 50, 75, 100 mm TR, TRS Series
Position Transducers with Restoring Spring 10, 25, 50, 75, 100 mm TR, TRS Series Special features long life 100 x 10 6 movements outstanding linearity up to ±0.075% choice of plug or cable connection DIN
More informationVoltage Regulator SPAU 341 C. Product Guide
Issued: July 1998 Status: Updated Version: D/25.04.2006 Data subject to change without notice Features Comprehensive voltage regulation for power transformers with on-load tapchangers in distribution substations
More informationFeatures. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument 4921210109D
7000/7000C/7020 Multi-instrument 4921210109D Features Measurements All 3-phase AC measurements True RMS Replaces analogue meters Demand on each phase current Accuracy U, I and F class 0.5 Other values
More informationLC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A - 220 V AC coil
Product data sheet Characteristics LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 -
More informationChrome DIN Rail Power Supply 12V 54W 1 Phase (Class II & NEC Class 2) / DRC-12V60W1AG
Highlights & Features Protection Class II, Double Isolation (No Earth connection is required) Universal AC input voltage and full power up to 55 C Power will not de-rate for the entire input voltage range
More informationDRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters
The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters Testing all relay technologies: electromechanical, solid state, numerical and IEC61850 Manual
More informationFuses for Semiconductor Protection - Cylindrical Fuses. Class: Voltage ratings: Current ratings: Standards: Approvals: Features and Benefits
Fuses for Semiconductor Protection - Cylindrical Fuses SIBA cylindrical Ultra-Rapid fuses are available in six different sizes They can be ordered with an integral striker for blown fuse indication or
More informationProduct and functional description
Product and functional description The KNX / DALI gateway N 141/02 is a 4 MU wide, DINrail mounted KNX device with one DALI interface to which up to 64 DALI actuators (e.g. DALI ballasts) can be connected
More informationCONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.
425 CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE General purpose single phase thyristors and solid state relays Product data abc 425 EUROCUBE A complete range of low cost solid state relays and
More informationDigital single-phase Energy-meters. Direct till 32 A 1 module DIN page 5. Direct till 45 A 1 module DIN page 6. Direct till 80 A 2 modules DIN page 7
Energy Meters INDEX 1 Measurement Digital single-phase Energy-meters Direct till 32 A 1 module DIN page 5 Digital single-phase Energy-meters Direct till 45 A 1 module DIN page 6 Digital single-phase Energy-meters
More informationPositive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous
Safety relay for monitoring E-STOP pushbuttons. Approvals Unit features Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous 1 auxiliary contact (N/C), instantaneous Safe separation of
More informationHow To Build A Low Voltage Capacitor Lvcp
Low Voltage Capacitor LVCP The new choice for Power Factor Correction LVCP : the new choice for Power Factor Correction The LVCP is a compact and powerful capacitor. It offers high modularity, unmatched
More informationT 3000. Substation Maintenance and Commissioning Test Equipment
T 3000 Substation Maintenance and Commissioning Test Equipment Multi function system for testing substation equipment such as: current, voltage and power transformers, all type of protection relays, energy
More informationElectronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact
Data sheet Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact The CT-AHD.12 is an electronic time relay with OFF-delay. It is from the CT-D range. With their MDRC profile and a width of only
More informationLow voltage Direct Current Network. Compact NSX DC PV. Circuit breakers and switch disconnectors for solar application.
Low voltage Direct Current Network Compact NSX DC PV Circuit breakers and switch disconnectors for solar application Catalogue 2012 Compact NSX DC PV A complete DC offer for solar application from 80
More informationCurrent and Energy. Measurement Technology
Current and Energy Measurement Technology Current Measurement and Evaluation WAGO s Solution for Energy Monitoring and Conservation Rogowski Coils, 855 Series Conversion of AC currents up to 500 A/2000
More informationTable of Contents. TransformerIQ FAQs 1
[12/12] FAQs Table of Contents FAQ 1. What size transformer will TransformerIQ monitor?... 2 FAQ 2. Are there different TransformerIQ versions?... 2 FAQ 3. How are the units powered?... 2 FAQ 4. What is
More informationZ-TRAUQ INC. Tel.: (450)226-6997 Fax: (450)226-5837 z-trauq@qc.aira.com
CURRENT TRANSFORMER MODEL J " x 7" PAGE No 2-2 REV 8DEC00 TERMINAL OPTION LEAD WIRE OPTION 8-2 BRASS SCREW TERMINALS (2 PLACES) SEE NOTE 9 6 9 8 6 Ø 2 9 (4 PLACES) UL 05 #6 AWG LEAD WIRE, STANDARD LENGTH
More informationISIO 200. Binary Input/Output (I/O) Terminal with IEC 61850 Interface
ISIO 200 Binary Input/Output (I/O) Terminal with IEC 61850 Interface Compact and Easy ISIO 200 Put your Binary I/Os where you need them ISIO 200 is a simple and versatile binary I/O terminal with IEC 61850
More informationMONITORING RELAYS. w VOLTAGE MONITORING RELAY UR5U1011. w SCHRACK-INFO. w TECHNICAL DATA
w VOLTAGE MONITORING RELAY UR5U1011 w SCHRACK-INFO AC/DC voltage monitoring in 1-phase mains Undervoltage monitoring 1 change over contact Width 17.5 mm Installation design w TECHNICAL DATA 502 1. Functions
More informationBETA Switching. Switching Devices. 5TT5 8 Insta contactors, AC technology. Overview
BETA Switching Siemens AG 200 5TT5 Insta contactors, AC technology Overview The 5TT5 Insta contactors are equipped with an AC magnetic system and are ideal for use under harsh conditions. The auxiliary
More informationSafety automation solutions
Operating principle, characteristics Preventa safety s types XPS AV,, For and switch monitoring Operating principle Safety s XPS AV, and are used for monitoring circuits conforming to standards EN/ISO
More informationABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.
1SR 430 824 F9300 Features Monitoring of three-phase mains for phase sequence and failure Powered by the measuring circuit 2 c/o (SPDT) contacts 1 LED for status indication Approvals R: yellow LED - relay
More informationMagnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...
Magnetic and Hydraulic-Magnetic Circuit Breaker 840-G2... Description Single, two and three pole magnetic circuit breakers with trip-free mechanism and push/pull on/off manual actuation. A choice of fast
More informationTemperature sensor with integrated transmitter for industrial applications, MBT 3560
Temperature sensor with integrated transmitter for industrial applications, MBT 3560 Technical brochure Features Designed for use in harsh industrial enviroments where reliable, robust and accurate equipment
More informationMaximum Demand Control
Maximum Demand Control There are three terms that appear on the majority of electric company bills: Active energy consumption (kwh) Reactive energy consumption (kvarh) Maximum Demand Traditionally, utility
More information5SV Residual Current Protective Devices
s Siemens AG 2013 SENTRON 5SV Residual Current Protective Devices New portfolio for reliable personnel, material and fire protection Safe protection against residual currents Residual current protective
More information40.3. Control Relays and Timers
.3 Contents EASY500/700/800 Intelligent Relays........ EASY/MFD Expansion Modules............ MFD Intelligent Relays................... EASY/MFD Communication Modules....... EASY/MFD Power Supplies, Accessories
More informationD-Line Contactors, Overload Relays and Accessories
D-Line Contactors, Overload Relays and Accessories Class 850 CONTENTS Description......................................................Page General Information...............................................
More informationThree-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41
Data sheet Three-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41 The three-phase monitoring relays CM-PSS.x1 monitor the phase parameters phase sequence, phase failure as well as over- and undervoltage.
More information3-Phase Energy meter with serial S-Bus interface
Data sheet www.sbc-support.com 3-Phase Energy meter with serial S-Bus interface Energy meters with an integrated S-Bus interface allow direct reading of all relevant data, such as energy (Total and partial),
More informationMILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)
MILLENIUM Table of contents 1. INTRODUCTION 1 2. HARDWARE DESCRIPTION 2 3. INSTALLATION 5 4. CONNECTION 6 5. USER SAFETY AND PROTECTION OF EQUIPMENT 8 1. Introduction The MILLENIUM series has been designed
More informationSHARKY 775 COMPACT ENERGY METER ULTRASONIC
APPLICATION The ultrasonic compact energy meter can be used for measuring the energy consumption in heating / cooling application for billing purposes. FEATURES 4 Approval for ultrasonic meter with dynamic
More informationType: EASY719 DC RC Article No.: 274119. Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description
Type: EASY719 DC RC Article.: 274119 Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC Description 12 digital inputs (4 inputs available as analog inputs) 6 relay outputs LCD display
More informationSEZ220. Signal Converter. Synco 200. With preprogrammed standard applications Freely programmable Menu-driven operation. Use
s 5 146 Synco 200 Signal Converter SEZ220 With preprogrammed standard applications Freely programmable enu-driven operation Use The signal converter is for use in HVAC plant to provide minimum / maximum
More informationIDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODELS: 61-763 61-765
IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODELS: 61-763 61-765 The Service Information provides the following information: Precautions and safety information Specifications Performance test procedure Calibration
More informationSTEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: 2868567. DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase
Extract from the online catalog STEP-PS/1AC/12DC/1.5 Order No.: 2868567 DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase Commercial data EAN 4046356292924 Pack 1 pcs. Customs tariff
More informationSafety Relays ESM/ESM-F
Safety Relays ESM/ESM-F More than safety. Safety More than safety. Emil Euchner, the company s founder and inventor of the multiple limit switch, circa 1928. Around the world the Swabian specialists in
More informationEnergy Management Energy Meter Type EM23 DIN
Energy Management Energy Meter Type EM23 DIN Class 1 (kwh) according to EN62053-21 Class B (kwh) according to EN50470-3 Class 2 (kvarh) according to EN62053-23 Accuracy ±0.5 RDG (current/voltage) Energy
More informationInsulation Resistance Testing of Low Voltage Cables in the Field
Insulation Resistance Testing of Low Voltage Cables in the Field Table of Contents 1. Background...3 1.1. Before Making Measurements...3 1.2. How to Apply the Temperature Correction Factor...4 1.2.1. Calculation...4
More informationTechnical Data. Dimensions
0102 Model Number Features Comfort series 5 mm flush Usable up to SIL 2 acc. to IEC 61508 Accessories BF 18 Mounting flange, 18 mm EXG-18 Quick mounting bracket with dead stop Technical Data specifications
More informationDirectory chapter 02 - DIN Power (to 6 A) Types D, E, F, FM, 2F, F9, interface connectors I/U 02. 01. Technical characteristics types D and E... 02.
Directory chapter 02 - () Types D, E, F, FM, 2F, F9, interface connectors I/U Page Technical characteristics types D and E.............................. 02.10 Type D connectors.................... 02.11
More informationSafety technique. Emergency stop module BO 5988 safemaster
Safety technique Emergency stop module BO 5988 safemaster 0221562 Function diagram Pushbutton on Mains or emergencystop () K1 According to EC Directive for machines 98/37/EG According to IEC/E 60204-1
More informationAF09-30-22-.. / AF09Z-30-22-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals
Technical Datasheet 1SBC101403D0201 24/03/11 AF09-30-22-.. / AF09Z-30-22-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals AF09(Z) contactors are used for controlling power circuits
More informationTelephone- and leased line modem for industrial applications TD-36
Telephone- and leased line modem for industrial applications TD-36 Modem for industrial PSTN- and leased line applications The TD-36 is an analogue V.34 PSTN modem as well as an industrial 2-wire leased
More informationAZ420 MINIATURE GENERAL PURPOSE RELAY
MINIATURE GENERAL PURPOSE RELAY FEATURES Rugged construction for high reliability Life expectancy greater than 0 million operations DC coils to 11 V Power consumption as low as 2 mw per pole available
More informationSeries 8146/5-V37 and Series 8150/5-V37
www.stahl.de > Clear assignment safe technology easy installation > Intelligent structure only one rotary actuator for frequency-controlled drives ) 20 ms leading auxiliary contact for safe motor disconnection
More informationSYSTEM DESCRIPTION Termination Boards
PROCESS AUTOMATION SYSTEM DESCRIPTION Termination Boards Non-IS Termination Boards for Yokogawa CENTUM C3 and ProSafe RS ISO9001 With regard to the supply of products, the current issue of the following
More informationADM1TE 5/30A DIN rail single phase two wire energy meter
ADMTE 5/30A DIN rail single phase two wire energy meter. Safety instruction.2 Foreword.3 Performance criteria.4 Specifications.5 Basic errors.6 Description.7 Dimensions.8 Installation.9 Operating.0 Troubleshooting.
More information