Introducing VE Thermowell
|
|
|
- Georgina Ellen Campbell
- 9 years ago
- Views:
Transcription
1 Thermowell
2 Introducing VE Thermowell Finally we can deliver the best possible performance AND safety, with total confidence in both. A complex and meticulously researched and engineered product, providing you the customer with a simple and assured application, every time. VE Technology have overcome an engineering challenge that has thwarted the thermowell industry for many years! We have discarded the traditional approach of a simply engineered product that requires complex and costly calculation and risk assessment for each application. Instead we have taken it upon ourselves to meticulously research and engineer a technically complex product, providing you the customer with a simple and assured application, every time. No longer do you need to make extensive, costly wake calculations to be confident your equipment is safe from vortex induced vibration. No longer is there a concern about thermowell failure or, worse still, a major pipeline failure caused by poor thermowell design. Finally we can deliver the best possible performance AND safety, with total confidence in both.
3 Vortex-Induced Vibration Rather than mitigating the symptom of vortexinduced vibration at the cost of performance and safety assurance, VE have tackled the root cause of this issue with science and engineering resulting in the safest AND best performing thermowell available. Vortex-induced vibration occurs when fast flowing fluid passes a bluff body, creating a pattern of disturbance (the Von Karman Street) that imparts alternating forces on the body. This well-documented effect can be seen in many industrial contexts and even in nature! The result of these forces is an oscillation of the body, both in line with the flow direction and transversely. If the frequency of these oscillations approaches the natural frequency of that body, resonant vibration can occur, with extreme stresses and truly destructive consequences. Typically, frequency calculations are made to ASME PTC 19.3 which often limit the safe insertion depth, at the cost of measurement accuracy. Furthermore, engineers complying with industry standards such as AGA9/ISO/ BS are forced to design excessively robust thermowells. However, these introduce hysteresis into thermal measurements and do not solve the problem: the vortex induced forces exist irrespective of strength and actually increase with increased diameter and may result in fatigue failure of the thermowell or potentially catastrophic stress cracking of pipeline welds. The Von Karman Street observed in cloud patterns as the cloud mass passes the mountainous island of Alejandro Selkirk Island, Chile. A Computational Fluid Dynamics (CFD) image observing the absence of vortices or downstream disturbance introduced by the thermowell in a flowing gas stream.
4 VE Thermowell VE Thermowell Materials Stainless Steel 316L (standard option), A105, Monel400, Duplex F51 (forged). Others by request. The VE Thermowell has a radical new design to give the best ever safety and performance. Not an aesthetic gimmick: the helical strake design is a result of years of extensive fluid dynamic and engineering research. The strake height, width, pitch and form are all meticulously calculated and precisely machined to effectively eliminate vortexinduced vibration. The VE Thermowell has a radical new design to give the best ever safety and performance. Helical strakes eliminate all vortex induced vibration. Aerodynamic tip minimizes flow disturbance. The thermowell is available as a single piece forging or welded to ASME standards and can be machined with an NPT connection thread, flange or any other connection type. All come with the exceptional VE Technology performance and reliability. VE Technology have patented this powerful technology across the globe, and have been unique in solving vibration issues and long unsupported insertion applications again and again. VE Technology have patented this powerful technology across the globe, and have been unique in solving vibration issues and long unsupported insertion applications again and again. Connection to Process Threaded flange (RF or RTJ) to ASME B16.5 welded to shaft according to ASME IX with dye pen testing, one-piece forged and machined structure. Others by request. Connection to Thermometer ½ Female NPT threaded connection as standard, custom available on request. Bore size and Insertion Length. To customer specification. Ordering Be sure to specify the following to ensure the best thermowell for your application: Material requirements. Process connection type and geometry (including pipeline standoff/insertion geometry). Non-standard thermometer connection details OR Supplier / Part Number of the device if you want a pre-assembled thermowell and sensor assembly. Media conditions: temperature, pressure, flow rate, viscosity, density.
5 Eliminate Uncertainty in Natural Gas Sampling Orbital. Cold Meece, Stone, Staffordshire ST15 0QN T: F: E: W:
Grant Agreement No. 228296 SFERA. Solar Facilities for the European Research Area SEVENTH FRAMEWORK PROGRAMME. Capacities Specific Programme
Grant Agreement No. 228296 SFERA Solar Facilities for the European Research Area SEVENTH FRAMEWORK PROGRAMME Capacities Specific Programme Research Infrastructures Integrating Activity - Combination of
Engineered Solutions
Engineered Solutions Long established partnerships bring together the world s leading instrumentation companies within BKW. Our manufacturing facility enables us to quickly adapt standard instruments to
Corrugated Tubular Heat Exchangers
Corrugated Tubular Heat Exchangers HEAT EXCHANGERS for the 21st CENTURY Corrugated Tubular Heat Exchangers (CTHE) Corrugated Tube Heat Exchangers are shell and tube heat exchangers which use corrugated
Using meters to measure steam flow
Page 1 of 6 April 1998 Plant Engineering SELECTING NEW TECHNOLOGY: PROBLEM SOLVING Using meters to measure steam flow Jesse L. Yoder, Ph.D., Senior Analyst, Automation Research Corp., Dedham, MA Key Concepts
Bimetal thermometer Model 52, industrial series
Mechanical temperature measurement Bimetal thermometer Model 52, industrial series WIKA data sheet TM 52.01 for further approvals see page 6 Applications A wide range of applications in machine building,
w o r k o G f E A x - p r S i t n c e Elegance and Strength BBR HiAm CONA Strand Stay Cable Damping Systems
e o b a l N e t w o r k l o G f E A x - p r S i t n c e 1 9 4 4 - s Elegance and Strength BBR HiAm CONA Strand Stay Cable Damping Systems 1 Cable vibration and damping Despite the wide use of cable-stayed
GMC 2013: Piping Misalignment and Vibration Related Fatigue Failures
GMC 2013: Piping Misalignment and Vibration Related Fatigue Failures www.betamachinery.com Authors/Presenters: Gary Maxwell, General Manager, BETA Machinery Analysis Brian Howes, Chief Engineer, BETA Machinery
The Unique Accelabar Flow Meter
The Unique Accelabar Flow Meter The Accelabar is a new and unique flow meter that combines two differential pressure technologies to produce operating ranges never before attainable in a single flow meter.
There are three primary static sealing methods in use today; the flat gasket. And the molded elastomer seal.
Flange Insulation Sealing Methods There are three primary static sealing methods in use today; the flat gasket. And the molded elastomer seal. The Flat Gasket is the oldest of the three. Where reusability
Improving Temperature Measurement to Optimize Inventory Control and Custody Transfer Systems
Improving Temperature Measurement to Optimize Inventory Control and Custody Transfer Systems The measurement of temperature is critical in the determination of the true volume of product in a hydrocarbon
DiwiTherm, Resistance Thermometers Model TR75, with digital Display Battery or Solar Powered
Electrical Temperature Measurement DiwiTherm, Resistance Thermometers Model TR75, with digital Display Battery or Solar Powered WIKA Data Sheet TE 60.75 Applications Machinery, plant and tank construction
Chapter 10. Flow Rate. Flow Rate. Flow Measurements. The velocity of the flow is described at any
Chapter 10 Flow Measurements Material from Theory and Design for Mechanical Measurements; Figliola, Third Edition Flow Rate Flow rate can be expressed in terms of volume flow rate (volume/time) or mass
Managing The Integrity Threat Of Subsea Pipework Fatigue Failure. John Hill Senior Consultant Xodus Group
Managing The Integrity Threat Of Subsea Pipework Fatigue Failure John Hill Senior Consultant Xodus Group Contents > Vibration-induced fatigue as an integrity issue subsea > Fatigue assessment of subsea
ORIFICE PLATES. CONCENTRIC BORE: For standard fluid conditions an Orifice Plate would have a centrally located orifice bore.
SUPERIOR PRODUCTS, INC. 20550 MADISON STREET, TORRANCE, CA 90503 ORIFICE PLATES MANUFACTURING STANDARDS: Superior Products manufactures Orifice Plates in strict accordance with the specifications of: AGA.,
NEW SIX-SEALS CUTTING RING. INTERNATIONAL INDUSTRIAL PATENT Nr. 864061 of the 10/03/99 FLANKS AND DOES NOT REPLACE THE STANDARD RING CURRENTLY IN USE
B4 NEW SIX-SEALS CUTTING RING. INTERNATIONAL INDUSTRIAL PATENT Nr. 864061 of the 10/03/99 FLANKS AND DOES NOT REPLACE THE STANDARD RING CURRENTLY IN USE AVAILABLE IN CARBON AND STAINLESS STEEL 23 THEORY
www.kem-kueppers.com [email protected] Certified according to DIN EN ISO 9001 Technical Datasheet KVO Series Vortex Flow Meter
www.kem-kueppers.com Certified according to DIN EN ISO 9001 Technical Datasheet KVO Series Vortex Flow Meter Description The KVO Vortex flow meters utilize two primary sensing elements a vortex shedding
MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter
Thermal Mass meter and Temperature Transmitter Description The MTI10 insertion thermal mass flowmeter and the MTL10 in-line thermal mass flowmeter provide accurate mass flow measurement of clean, dry gases
OPTIMASS 6000 Technical Datasheet
OPTIMASS 6000 Technical Datasheet Sensor for mass flow The high performance meter for process industries Cryogenic, high temperature and high pressure options Supreme liquid and gas performance with CT
For Multi-Parameter Meters see mvx
BULLETIN BULLETIN EM20607 VORTEX IN-LINE FLOW METERS Design Features For Multi-Parameter Meters see m Principles of Operation n No moving parts to wear or fail. n Electronics can be remotely mounted up
Offshore Requirements for Turbine Exhaust System Analysis and Design
Proceedings of the Twenty-fifth (2015) International Ocean and Polar Engineering Conference Kona, Big Island, Hawaii, USA, June 21-26, 2015 Copyright 2015 by the International Society of Offshore and Polar
Sentinel LCT. Panametrics Ultrasonic Flowmeter for Liquid Custody Transfer Measurement. GE Measurement & Control Solutions. Benefits.
GE Measurement & Control Solutions Sentinel LCT Panametrics Ultrasonic Flowmeter for Liquid Custody Transfer Measurement Benefits Extremely reliable and highly accurate flowmeter, designed specifically
Energy and Flow Measurement for Hydronic Systems
Energy and Flow Measurement for Hydronic Systems Presented By: George Szyszko Applications Consultant MCR for ONICON Incorporated Why Measure Thermal Energy? To control something, you must first measure
Custody Transfer Measurement. with the V-Cone Flowmeter
Custody Transfer Measurement with the V-Cone Flowmeter Stephen A. Ifft McCrometer Inc. Hemet, California, USA Abstract This paper will discuss the approval of the McCrometer V-Cone flowmeter for custody
Ve-Lock manufactures Needle Valves from Solid bar stock Materials & all parts details are as below:
Needle Valves : - Needle valves have a slender, tapered point at the end of the valve stem that is lowered through the seat to restrict or block flow. Fluid flowing through the Needle valve turns 90 degrees
VorTek Series M22 and M23 Pro-V Vortex Flow Meters. Instruction Manual
Model M22/M23 Instruction Manual Table of Contents VorTek Series M22 and M23 Pro-V Vortex Flow Meters Instruction Manual Document Number M-000-00001 M22/M23, V Rev 06/08 8475 W I-25 Frontage Rd. Suite
COUNTERBALANCE VALVES
COUNTERBALANCE VALVES Introduction They are modulating valves which allow free flow into the actuator and then block the reverse flow until they feel a pilot pressure inversely proportional to the load
THERMOMETER INSTALLATION, OPERATION AND MAINTENANCE
THERMOMETER INSTALLATION, OPERATION AND MAINTENANCE www.winters.com MANUFACTURER OF INDUSTRIAL INSTRUMENTATION Bi-Metal Thermometers Bi-Metal Thermometers Winters bi-metal thermometers are direct sensing
Threaded Resistance Thermometers Model TR10-D, Miniature Design
Electrical Temperature Measurement Threaded Resistance Thermometers Model TR10-D, Miniature Design WIKA Data Sheet TE 60.04 Applications Machine building, plant and tank construction Power transmission
ABB Flowmeters Review of industrial processing flowmeters
White paper ABB Flowmeters Review of industrial processing flowmeters Understanding flowmeters and their pros and cons By Ron DiGiacomo, ABB Measurement Products One of the most critical measurements in
A LAMINAR FLOW ELEMENT WITH A LINEAR PRESSURE DROP VERSUS VOLUMETRIC FLOW. 1998 ASME Fluids Engineering Division Summer Meeting
TELEDYNE HASTINGS TECHNICAL PAPERS INSTRUMENTS A LAMINAR FLOW ELEMENT WITH A LINEAR PRESSURE DROP VERSUS VOLUMETRIC FLOW Proceedings of FEDSM 98: June -5, 998, Washington, DC FEDSM98 49 ABSTRACT The pressure
Turbine Flowmeters for Gas Applications
Turbine Flowmeters for Gas Applications Description Flow Technology s FT Series turbine flowmeters utilize a proven flow measurement technology to provide exceptionally reliable digital outputs. Because
Operataing Manual. Single stage radial Fan. Model MKV/TKV
01.2011 Operataing Manual Single stage radial Fan Model MKV/TKV REITZ-SCHWEIZ VENTILATOR AG Zentweg 11 CH-3006 Bern Telefon +41 (0) 31 / 938 85-85 Telefax +41 (0) 31 / 938 85-86 Internet: www.reitz-schweiz.ch
SERIES ASM NEOPRENE/EPMD FLANGED SINGLE SPHERE CONNECTOR CONNECTORS. Pressures to 225 PSIG (15.51 barg) Temperatures to 230ºF (110ºC)
APPLICATIONS Process Industry Weak Acids Alkalies Compressed Air Pulp & Paper MODELS ASM - Flanged Connection OPTIONS Control Rods Oil & Gas Water & Waste Pump suction & discharge Sea water Chemical lines
Design and Analysis of Various Bluff Objects for Vortex flow meters
Design and Analysis of Various Bluff Objects for Vortex flow meters T. Milinda Purna 1, L. Aarya 2, K. Lakshmi Nageswari 3 1 Assistant Professor, Department Of Electronics & Instrumentation, Sree Vidyanikethan
5.23.22 STEAM AND CONDENSATE PIPING AND PUMPS DESIGN AND CONSTRUCTION STANDARD PART 1: GENERAL. 1.01 Purpose:
PART 1: GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is
Leading Technologies and Services for a Safe Plant Operation
Products Solutions Services Safety by Design Mechanical integrity. safety in the design phase. safety in the manufacturing phase. safety in the field operation phase Leading Technologies and Services for
Advances in Thermal Dispersion Mass Flow Meter Accuracy
Advances in Thermal Dispersion Mass Flow Meter Accuracy By Dan McQueen President Fluid Components International (FCI) Advances in Thermal Dispersion Mass Flow Meter Accuracy By Dan McQueen President Fluid
Flange Insulation Sets
Insulation sets are used to limit corrosion in pipeline systems. Where dissimilar metals are present, the sets remove the possibility of the system acting as a galvanic cell and reduce the risk of galvanic
inter.noise 2000 The 29th International Congress and Exhibition on Noise Control Engineering 27-30 August 2000, Nice, FRANCE
Copyright SFA - InterNoise 2000 1 inter.noise 2000 The 29th International Congress and Exhibition on Noise Control Engineering 27-30 August 2000, Nice, FRANCE I-INCE Classification: 2.1 WHISTLING PHENOMENA
Helical Gears K HG 1-20 R. Table of Contents. Catalog Number of KHK Stock Gears. Helical Gears. (Example) Direction of Helix (R) No.
Table of Contents Special Characteristics, Points of Caution in Selecting and Using... page 130 KHG Ground... page 134 SH... page 144 Catalog Number of KHK Stock Gears The Catalog Number for KHK stock
Michael Montgomery Marketing Product Manager Rosemount Inc. Russ Evans Manager of Engineering and Design Rosemount Inc.
ASGMT / Averaging Pitot Tube Flow Measurement Michael Montgomery Marketing Product Manager Rosemount Inc. Russ Evans Manager of Engineering and Design Rosemount Inc. Averaging Pitot Tube Meters Introduction
M. Belloli, A. Collina, F. Resta Politecnico di Milano O.I.T.A.F. SEMINAR. Grenoble 27 April 2006
Cables vibrations due to wind action M. Belloli, A. Collina, F. Resta Politecnico di Milano O.I.T.A.F. SEMINAR Grenoble 27 April 2006 Presentation Main topic of the presentation is the vibrations of cables
Flanged and Butt-= Weld Type
Document : PG00 Year : 09 Product Group 00 Flanged and Butt-= Weld Type (LNG and LPG) Page 09 Document : PG00 Year : 09 Product Group 00 Cryogenic Butterfly valves The Cryogenic Butterfly Valve Design
Turbine Flow Sensor Series VTR
Turbine Flow Sensor Series VTR SIKA Turbine Flow Sensor Series VTR Extra robust, impressively precise SIKA s VTR turbine flow sensor allows you to determine precisely, dependably and easily the flow rates
Vehicle Brake System Monitoring 2-wire, 4-20 ma option; Intrinsic Safety Approval to E Exia IIC T4 (Tamb=60 C) BASEEFA, CENELEC EN50-020
Field proven rugged construction High overpressure capability High reliability for demanding environments Application specific customization Excellent media compatibility Shock and vibration resistant
FLUID FLOW Introduction General Description
FLUID FLOW Introduction Fluid flow is an important part of many processes, including transporting materials from one point to another, mixing of materials, and chemical reactions. In this experiment, you
Differential-Hall-Effect based Sensors Series A5S
Speed and Frequency Seite 1 von 6 Differential-Hall-Effect based Sensors Series A5S Outstanding Characteristics Speed range covering most demands: from close to zero up to 25,000 pulses/second (response
OPTIMASS 1400 Technical Datasheet
OPTIMASS 1400 Technical Datasheet Sensor for mass flow First choice for universal applications Best price-performance ratio A wide range of options available with no restrictions The documentation is only
Micro Motion Model D and DL Coriolis Flow and Density Meters
Product Data Sheet PS-00388, Rev. F April 2013 Micro Motion Model D and DL Coriolis Flow and Density Meters Micro Motion Model D and DL sensors provide flow and density measurement for liquids, gases,
RING TYPE JOINT GASKETS
RING TYPE JOINT GASKETS 05.07 GLOBAL RESOURCE FLEXITALLIC, A WORLDWIDE ORGANIZATION LOCAL SERVICE COMMITTED TO MEETING CUSTOMER NEEDS COMPREHENSIVE PRODUCT RANGE FOR ALL INDUSTRIAL AND PETROCHEMICAL APPLICATIONS
How To Use A Flowmeter
INLINE flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both PNP and NPN) Connection
Prof. Dr. Zahid A. Siddiqi, UET, Lahore WIND LOAD
WIND LOAD Wind load is produced due to change in momentum of an air current striking the surface of a building. A building is less likely to experience the other design loads in its life but it is almost
Department of Chemical Engineering, National Institute of Technology, Tiruchirappalli 620 015, Tamil Nadu, India
Experimental Thermal and Fluid Science 32 (2007) 92 97 www.elsevier.com/locate/etfs Studies on heat transfer and friction factor characteristics of laminar flow through a circular tube fitted with right
Solid shape molding is not desired in injection molding due to following reasons.
PLASTICS PART DESIGN and MOULDABILITY Injection molding is popular manufacturing method because of its high-speed production capability. Performance of plastics part is limited by its properties which
Style 07 Zero Flex Rigid Coupling. Style 75 Flexible Coupling. Style 77 Flexible Coupling 11. Description
Style 07 Zero Flex Rigid Coupling The unique angled pad design adjusts to standard pipe tolerances to positively clamp the pipe to resist flexural and torsional loads. Working pressures are based on standard
InvoMilling AGILE GEAR MANUFACTURING
InvoMilling AGILE GEAR MANUFACTURING Cutting lead times in gear manufacturing Machining gears normally requires dedicated tools for the specific gear profile. With the patented InvoMilling process it is
Pipe threads for tubes and fittings where pressure-tight joints are not made on the threads. (requires PTFE sealing tape or liquid sealant).
Fittings for CO 2 Pipe Threads Pipe thread references quoted in this catalogue conform with the requirements specified in the latest issue and amendments of the following ISO Standards: ISO 7-1 (BS21)
The Augustus Group Products Projects and Engineering Consulting. ASME BOILER AND PRESSURE VESSEL CODE Mike Looram
The Augustus Group Products Projects and Engineering Consulting ASME BOILER AND PRESSURE VESSEL CODE Mike Looram ASME B&PV CODE SECTION VIII DIV. 1 Bolted Flanges With Ring Type Gaskets Stress Calculations
James M. Pleasants Company
James M. Pleasants Company SUBMITTAL DATA GAINESVILLE MECHANICAL DECEMBER 20, 2013 PROJECT: GSU: J-183 HUMANITIES LAW BLDG. QUOTE NO:12116 ENGINEER: STEVENS & WILKINSON GASKETED PLATE HEAT EXCHANGER Tag:
Laminar and Turbulent flow. Flow Sensors. Reynolds Number. Thermal flow Sensor. Flow and Flow rate. R = Mass Flow controllers
Flow and Flow rate. Laminar and Turbulent flow Laminar flow: smooth, orderly and regular Mechanical sensors have inertia, which can integrate out small variations due to turbulence Turbulent flow: chaotic
A strong team for economical concrete paving. Slipform Paver SP 1500
A strong team for economical concrete paving Slipform Paver SP 1500 Where concrete paving is concerned, this work train is a fast train Two layers, one machine Rarely does the technical and economical
Online data sheet PET-1CB010N10SVMC PET PRESSURE SENSORS
Online data sheet PET-1CB010N10SVMC PET B C D E F H I J K L M N O P Q R S T Illustration may differ Detailed technical data Features Pressure type Measuring range Ordering information Other models and
FLAME CuTTIng te la P is utting B c
FLAME CUTTING Both Oxy-LPG and Oxy-acetylene processes are acceptable for sectioning all thicknesses of BISPLATE. With these processes, the following techniques are recommended: Gas pressure to be the
Temperature Calibration; Depths of Immersion
Temperature Calibration; epths of Immersion Author: John P. Tavener Company Isothermal Technology Limited, Pine Grove, Southport, England Abstract Of all the sources of errors and uncertainties in thermal
Many Products...One Source
PRESSURE GAUGES Dedicated Sales Rep for Your Area 97%Fill Rate Shipping within 24 Hours State of the Art Warehouse System Technical Support Quality Control Program 25 Whaley Avenue Milverton, Ontario N0K
Module 2 GEARS. Lecture 3 - INVOLUTE SPUR GEARS
Module 2 GEARS Lecture 3 - INVOLUTE SPUR GEARS Contents 3.1 Introduction 3.2 Standard tooth systems for spur gears 3.3 Profile shifted gears 3.4 Involutometry 3.5 Design of gear blanks 3.1 INTRODUCTION
INJECTION MOLDING COOLING TIME REDUCTION AND THERMAL STRESS ANALYSIS
INJECTION MOLDING COOLING TIME REDUCTION AND THERMAL STRESS ANALYSIS Tom Kimerling University of Massachusetts, Amherst MIE 605 Finite Element Analysis Spring 2002 ABSTRACT A FEA transient thermal structural
Pipe Cutting and Beveling Clamshells
Pipe Cutting and Beveling Clamshells Who We Are One Company, Total Support, Complete Solutions For more than a century, Hydratight has provided world-class bolted joint solutions and continues to set international
SECTION 02720 SANITARY SEWER AND STORM DRAIN SYSTEMS
SECTION 02720 SANITARY SEWER AND STORM DRAIN SYSTEMS PART 1 GENERAL 1.01 SECTION INCLUDES A. The requirements for pipe material and installation in sewer and drainage collection systems. All materials
Milling. COPYRIGHT 2008, Seco Tools AB 1/111
Milling 1/111 2/111 Milling A simple choice! Experts required? No Just follow some basic rules. 3/111 Face milling 4/111 Square shoulder milling 5/111 Disc milling 6/111 Copy milling 7/111 Plunge milling
Self-operated Temperature Regulators Temperature Regulator Type 1u
Self-operated Temperature Regulators Temperature Regulator Type u Application Temperature regulators for cooling installations Control thermostats for set points ) from 0 to 250 C G ½ to G or DN 5 to 50
The simulation of machine tools can be divided into two stages. In the first stage the mechanical behavior of a machine tool is simulated with FEM
1 The simulation of machine tools can be divided into two stages. In the first stage the mechanical behavior of a machine tool is simulated with FEM tools. The approach to this simulation is different
9000 Series Accelerometers Specifications
Technical Data 9000 Series Accelerometers Specifications Catalog Numbers EK-43781I, EK-43782I, EK-46255I, EK-45890I, EK-43784I, EK-47086I, EK-43792I, EK-47090I, EK-43799I, EK-43794I, EK-43795I, EK-43797I,
The First Line of Safety
Pilot Operated Pressure Relief Valves The First Line of Safety Pilot Operated Pressure Relief Valves 597C Farris Engineering Pressure Relief Valves Process Pressure Relief Valves Series 2600 ASME NB Certified:
1-800-654-3872 1-405-273-6302
Anodeless Risers Transition Risers Compression Risers Riser Accessories Transition Risers and Transitions The Right Connection 1-800-654-3872 1-405-273-6302 www.centralplastics.com Risers and Transitions:
www.klmtechgroup.com TABLE OF CONTENT
Page : 1 of 16 Project Engineering Standard www.klmtechgroup.com KLM Technology #03-12 Block Aronia, Jalan Sri Perkasa 2 Taman Tampoi Utama 81200 Johor Bahru Malaysia ORIFICE FLANGES TABLE OF CONTENT SCOPE
Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm
Electronic pressure measurement Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm WIKA data sheet PE 81.67 Applications Machine tools Hydraulics
Thermal Dispersion Mass Flow
Thermatel Thermal Dispersion Mass Flow Measurement Handbook Table of Contents Introduction...1 What is Mass Flow Measurement?...1 Types of Flow Transmitters...4 Differential Pressure...4 Orifice...4 Venturi...6
Thermometer in stainless steel with capillary and switch contacts
Design Type Case diameter Thermometer in and switch contacts 7308 = back flange for wall mounting 7312 = front flange for panel mounting 7310 = mounting bracket for wall mounting Dim 100 mm or 160 mm Accuracy
Machine devices, jig devices
Machine devices, jig devices 853 K0697 Rolled thread studs DIN 6379 Material: Tempered steel. KIPP Rolled thread studs DIN 6379 Order No. D L B1 B2 Approx. weight g Surface finish: Thread rolled. Class
Making a Case for a New Connector
Research on an Optimal Design for QMA and QN Connectors IEEE, Feature Article in Microwave Magazine February, 2008 Volume: 9 Issue:1 The emergence of Quick Lock connectors, particularly Quick Lock versions
SPIRAL WOUND GASKETS Driven by the industry's need for safe, effective sealing solutions, Flexitallic invented the spiral wound gasket.
innovate/customize/educate SPIRAL WOUND GASKETS Driven by the industry's need for safe, effective sealing solutions, Flexitallic invented the spiral wound gasket. www.flexitallic.eu FLEXITALLIC The Flexitallic
OEM Pressure Transmitters for heavy-duty applications, Type MBS 1200 and MBS 1250
MAKING MODERN LIVING POSSIBLE Data sheet OEM Pressure Transmitters for heavy-duty applications, Type MBS 1200 and MBS 1250 The compact OEM pressure transmitter programme is designed for use in severe hydraulic
Alternative Linear Motion Systems. Iron Core Linear Motors
Alternative Linear Motion Systems ME EN 7960 Precision Machine Design Topic 5 ME EN 7960 Precision Machine Design Alternative Linear Motion Systems 5-1 Iron Core Linear Motors Provide actuation forces
KEYSTONE. Stainless steel hygienic butterfly valves F250 for imperial tubing F251 for metric tubing
KEYSTONE Stainless steel hygienic butterfly valves F0 for imperial tubing F for metric tubing Features Keystone technology. Quarter turn operation. Isolation or regulation control. Equal percentage characteristics.
Stainless Steel Pipe Fabrication
Stainless Steel Pipe Fabrication Dr M J Fletcher, Delta Consultants, Rutland UK We are now all too familiar with demands to reduce manufacturing costs. Fabrication of stainless steel poses particular problems.
www.klmtechgroup.com TABLE OF CONTENT
Page : 1 of 31 Project Engineering Standard www.klmtechgroup.com KLM Technology #03-12 Block Aronia, Jalan Sri Perkasa 2 Taman Tampoi Utama 81200 Johor Bahru Malaysia TABLE OF CONTENT SCOPE 2 REFERENCES
Take total control of your HVAC system with cost-saving flow and thermal energy meters
Take total control of your HVAC system with cost-saving flow and thermal energy meters Because you can t manage what you don t measure usa.siemens.com/pi Answers for Industry. Contents Introduction 03
Review on Experimental Analysis and Performance Characteristic of Heat Transfer In Shell and Twisted Tube Heat Exchanger
Review on Experimental Analysis and Performance Characteristic of Heat Transfer In Shell and Twisted Tube Heat Exchanger Nitesh B. Dahare Student, M.Tech (Heat power Engg.) Ballarpur Institute of Technology,
Piston Accumulators. SK Series. Accumulator Catalog. Piston Types. Description. Sealing Systems. End Cap. O-ring. Sealing System. Piston.
SK Series Piston Types TYPE 2 pplication: Low-friction design for higher piston speeds, slow movements without stick-slip effect and high number of actuations (millions). ctual cycles achieved will vary
Der Einfluss thermophysikalischer Daten auf die numerische Simulation von Gießprozessen
Der Einfluss thermophysikalischer Daten auf die numerische Simulation von Gießprozessen Tagung des Arbeitskreises Thermophysik, 4. 5.3.2010 Karlsruhe, Deutschland E. Kaschnitz Österreichisches Gießerei-Institut
Engineering Your Competitive Edge. Applications of Kennametal mill rolls
Engineering Your Competitive Edge of Kennametal mill rolls Tungsten carbide is a proven material for many stands in the rolling mill industry. Tungsten carbide grades developed by KENNAMETAL EPG achieve
Thermal Mass Flow Meter (Series MST)
Overview MaxiFlo TM MST series Thermal Mass Flow Meter is the instrument of choice for reliable and accurate measurement of mass flows for various gases. It measures the mass flow of gas based on constant
Flow Sensors. - mass flow rate - volume flow rate - velocity. - stream line parabolic velocity profile - turbulent vortices. Methods of measurement
Flow Sensors Flow - mass flow rate - volume flow rate - velocity Types of flow - stream line parabolic velocity profile - turbulent vortices Methods of measurement - direct: positive displacement (batch
Series 240 Type 3244-1 and Type 3244-7 Pneumatic Control Valves Type 3244 Three-way Valve
Series 240 Type 3244-1 and Type 3244-7 Pneumatic Control Valves Type 3244 Three-way Valve DIN and ANSI versions Application Mixing or diverting valve for process engineering and industrial applications
Abaqus/CFD Sample Problems. Abaqus 6.10
Abaqus/CFD Sample Problems Abaqus 6.10 Contents 1. Oscillatory Laminar Plane Poiseuille Flow 2. Flow in Shear Driven Cavities 3. Buoyancy Driven Flow in Cavities 4. Turbulent Flow in a Rectangular Channel
A global supplier of quality instrumentation/piping specification valves through product design and reliability for total customer satisfaction
Made in Britain Valves and Manifolds Double Block and Bleed Valves Monoflange Valve Chart Recorders Calibration Equipment Positioners Accessories A global supplier of quality instrumentation/piping specification
High Pressure Equipment Pressure Vessels and Reactors Index
Pressure Vessels and Reacrs High Pressure Equipment Company designs and manufactures a broad range of pressure vessels and reacrs for both bench-scale and pilot plant applications. We have over 0 standard
Operation Manual For NDJ-8S Digital Rotary Viscometer
Operation Manual For NDJ-8S Digital Rotary Viscometer 1 Contents 1. General... 2 2. Main technical data... 2 3. Working principle... 2 4. Installation... 3 5. Operation procedures... 4 6. Precautions...