Thermometer in stainless steel with capillary and switch contacts

Save this PDF as:
 WORD  PNG  TXT  JPG

Size: px
Start display at page:

Download "Thermometer in stainless steel with capillary and switch contacts"

Transcription

1 Design Type Case diameter Thermometer in and switch contacts 7308 = back flange for wall mounting 7312 = front flange for panel mounting 7310 = mounting bracket for wall mounting Dim 100 mm or 160 mm Accuracy Class 1,0% DIN EN Case Mounting Temperature element Working temperature Capillary Stem Length of stem Connection Working pressure Stainless steel with bayonet type bezel white dial of aluminium. Laminated safety glass. Back flange, front flange or mounting bracket Inert gas expansion system 100% of range by permanent measuring The endvalue can be excided 20% by short time Capillary of stainless steel (dim Ø2 mm) Ø 6, 8, 10 or 12 mm of stainless steel Stem length from 70 mm to 300 mm Type 1 = Plain stem without thread Type 2 = Male nut Type 3 = Union nut Type 4 = Compression fitting on stem Type 6 = Compression fitting on capillary Max pressure rating without thermowell = 25 bar Ingress protection IP 65 per EN Switch contacts Switch functions Electrical connection Optional extras Sliding contacts type 811, magnetic snap-action contacts type 821 or inductive contacts type 831. One, two or three switch contacts adjustable over the full extent of the scale range. Single or double function, see table next page Junction box at side Scale range in C+F (dual scale) Case with liquid damping (not by contact type 811) Version per ATEX Ex II 2 GD c TX Contacts with separate circuits Changeover contacts Temperature range C C 0+60 C 0+80 C C C C C C C C C

2 Magnetic snap-action contact type 821 Magnetic snap-action contact. Power supply max 250 VAC. Maximum load 30W, 50 VA, Current ratings max 1,0 A, Maximum load max 20W, 20 VA with liquid damped case Contact point material silver-nickel alloy, hysteresis 2-4% of full scale range. Single contact Double contacts Triple x max 1 x min 2 x max min - max max - min 2 x min 2 max 1 min by rising and falling and breakes Sliding contact type 811 Sliding contact. Power supply max 250 VAC. Maximum load 10W, 18 VA, Current ratings max 0,7 A (type 811 can not be delivered with liquid damped case) Contact point material silver-nickel alloy, hysteresis 2-4% of full scale range. Single contact Double contacts Triple x max 1 x min 2 x max min - max max - min 2 x min 2 max 1 min by rising and falling and breakes

3 Inductive contact type 831 Inductive contact type 831 is used in conditions with extremely swift changes or in explosion hazardous areas type Ex. Contact point material silver-nickel alloy, hysteresis 0,5% of full scale range. The inductive contact must be connected to a control unit which provide a low voltage to the contact. The control unit operates together with the inductive contact for functions as making or breaking the circuit. See datasheet E Single contact Double contacts Trippel xxx On special request 1 x max 1 x min 2 x max min - max max - min 2 x min Case with back flange type 7308 Type Case dim b1 c d d1 d2 d3 D1 D , 8, 10, , , 8, 10, ,

4 Case with front flange type 7312 Case dim b1 c d d1 d2 d3 D1 D , 8, 10, , , 8, 10, , Case with mounting bracket type 7310

5 Connection and stem Connection typ 1 Plain stem without thread Immersion length L1 and Connection typ 2 Male nut Connection typ 3 Union nut Connection typ 4 Compression fitting on stem Connection typ 6.1 Compression fitting on capillary Connection typ 6.2 Compression fitting on capillary with spiral protection hose Connection typ 6.3 Compression fitting on capillary on spiral protection hose

Pressure gauge in stainless steel version with electrial alarm contact. Suitable for aggressive media and environment. DIN 16085

Pressure gauge in stainless steel version with electrial alarm contact. Suitable for aggressive media and environment. DIN 16085 Design Type WIKA type no Case diameter Pressure gauge in stainless steel version with electrial alarm contact. Suitable for aggressive media and environment. DIN 16085 2850 contact = stainless steel 2950

More information

Gas Actuated Thermometers Combi-Thermometers with Pt100 Stainless Steel Series, Model 76

Gas Actuated Thermometers Combi-Thermometers with Pt100 Stainless Steel Series, Model 76 Mechanical Temperature Measurement Gas Actuated Thermometers Combi-Thermometers with Pt100 Stainless Steel Series, Model 76 WIKA Data Sheet TM 76.01 Applications For aggressive media in chemical, petrochemical,

More information

Bimetal thermometer Model 55, stainless steel version

Bimetal thermometer Model 55, stainless steel version Mechanical temperature measurement Bimetal thermometer Model 55, stainless steel version WIKA data sheet TM 55.01 for further approvals see page 7 Applications General process instrumentation in the chemical

More information

Bimetal thermometer Model 52, industrial series

Bimetal thermometer Model 52, industrial series Mechanical temperature measurement Bimetal thermometer Model 52, industrial series WIKA data sheet TM 52.01 for further approvals see page 6 Applications A wide range of applications in machine building,

More information

Bourdon tube pressure gauge with switch contacts Models PGS23.1x0, stainless steel version

Bourdon tube pressure gauge with switch contacts Models PGS23.1x0, stainless steel version Mechatronic pressure measurement Bourdon tube pressure gauge with switch contacts Models PGS23.1x0, stainless steel version k Applications for further approvals see page 14 WIKA data sheet PV 22.02 Control

More information

Diaphragm Seal with flush diaphragm and flange acc.to SMS. Completed with pressure gauge in stainless steel, liquid filled or pressure transmitter

Diaphragm Seal with flush diaphragm and flange acc.to SMS. Completed with pressure gauge in stainless steel, liquid filled or pressure transmitter Ed.15.01 Design Diaphragm Seal with flush diaphragm and flange acc.to SMS. Completed with pressure gauge in stainless steel, liquid filled or pressure transmitter Standard 4026/60H Pressure rate PN 40

More information

DiwiTherm, Resistance Thermometers Model TR75, with digital Display Battery or Solar Powered

DiwiTherm, Resistance Thermometers Model TR75, with digital Display Battery or Solar Powered Electrical Temperature Measurement DiwiTherm, Resistance Thermometers Model TR75, with digital Display Battery or Solar Powered WIKA Data Sheet TE 60.75 Applications Machinery, plant and tank construction

More information

2.12. page 223 2.12. Products for Explosion hazardous Environment

2.12. page 223 2.12. Products for Explosion hazardous Environment 2.12 page 223 2.12 Products for Explosion hazardous Environment Non-electric valves for explosion 2.12.1 page 224 hazardous environment The following manually and mechanically actuated valves are available

More information

T R A N S F O R M E R A C C E S S O R I E S SAM THERMOMETERS

T R A N S F O R M E R A C C E S S O R I E S SAM THERMOMETERS THERMOMETERS BIMETA THERMOMETERS (DIN 1 1 - PART 2) TYPE: MBT 7 2 4 8 1 12 C APPICATION This thermometer is designed for indication of oil temperature in both transformers with epansion conservator or

More information

Plastic tube flowmeters Series PT/PS

Plastic tube flowmeters Series PT/PS Plastic tube flowmeters Variable area flowmeter for liquids and gases Low cost, excellent readability and light weight Simple installation (flanged, threaded or socket ends for solvent or fusion welding

More information

Safety at a high level!

Safety at a high level! SIKA Level Switch SIKA Level Switch Safety at a high level! Convincing Advantages easy and reliable method to monitor fluid levels proven float principle easy side installation using threads ¾" or ½" BSP

More information

Threaded Resistance Thermometers Model TR10-D, Miniature Design

Threaded Resistance Thermometers Model TR10-D, Miniature Design Electrical Temperature Measurement Threaded Resistance Thermometers Model TR10-D, Miniature Design WIKA Data Sheet TE 60.04 Applications Machine building, plant and tank construction Power transmission

More information

VDL 53 - Vacuum drying oven for flammable solvents

VDL 53 - Vacuum drying oven for flammable solvents Vacuum drying ovens VDL 53 - Vacuum drying oven for flammable solvents The VDL series ensures maximum safety when drying organic solvents in accordance with TÜV/GS guidelines. The interior chamber is designed

More information

Inductive sensor NI10-M18-Y1X-H1141

Inductive sensor NI10-M18-Y1X-H1141 ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Threaded barrel, M18 x 1 Chrome-plated brass DC 2-wire, nom. 8.2 VDC Output acc. to DIN EN 60947-5-6 (NA- MUR) M12

More information

Digital display DA 48

Digital display DA 48 Loop powered plug-in LCD display No auxiliary energy source needed Scale freely adjustable on site Can be turned to any position Suitable for any 0 ma transmitter with EN 175301-803A connector Digital

More information

Mini pressure switch Stainless steel switch enclosure Model PXS

Mini pressure switch Stainless steel switch enclosure Model PXS Mechatronic pressure measurement Mini pressure switch Stainless steel switch enclosure Model PXS WIKA data sheet PV 34.36 Process Mini Series Applications Pressure monitoring and control of processes Safety-critical

More information

System 6000 Electropneumatic Converter for Direct Current Signals Type 6111 i/p Converter

System 6000 Electropneumatic Converter for Direct Current Signals Type 6111 i/p Converter System 6000 Electropneumatic Converter for Direct Current Signals Type 6111 i/p Converter Application Used to convert a direct-current input signal into a pneumatic output signal for measuring and control

More information

OLI. Oil level indicator

OLI. Oil level indicator OLI Oil level indicator Oil level indicator Unexpected or accidental oil leakages may occur randomly along transformer s lifetime. Clear indication of oil level inside transformer tank and on load tap

More information

79 GAUGE / THERMOMETER H N O

79 GAUGE / THERMOMETER H N O 79 GAUGE / TERMMETER plastic-housing 80 A 100 - D 40 Centre back entry and are not aggressive to copper alloys. Design: E 837-1. Case: black plastic. Dial: white plastic. Window: clear plastic. Pressure

More information

Flow switches Series AD/VH

Flow switches Series AD/VH Flow switches Flow switch and indicator for liquids and gases Suitable for clear, opaque or turbid liquids (series AD & VH), and for gases (series AD) Flow switching by means of magnetic coupling, watertight,

More information

S GATE KNIFE GATE VALVE WITH PNEUMATIC ACTUATOR

S GATE KNIFE GATE VALVE WITH PNEUMATIC ACTUATOR MAIN FEATURES The pneumatic S GATE knife gate valve is intended for the automatic shut off of pipes of the heavy fluids like slurries and powders. The main fields of application are the water treatment,

More information

NIVOCONT CONDUCTIVE LEVEL SWITCHES LEVEL SWITCHES

NIVOCONT CONDUCTIVE LEVEL SWITCHES LEVEL SWITCHES NIVOCONT CONDUCTIVE LEVEL SWITCHES O U R P R O F E S S I O N I S Y O U R L E V E L LEVEL SWITCHES APPLICATION Level switches, based on the conductivity principle, can be applied to liquids with conductivity

More information

Stainless steel process fittings

Stainless steel process fittings Page 1/6 Stainless steel process fittings Installation in pipe systems Installation in tanks and vessels Hygienic version FDA conformity of materials Probe length 120 mm 120 mm Availability of various

More information

System 8. ü www.nassmagnet.com ( +49 511 6746-0. System 8

System 8. ü www.nassmagnet.com ( +49 511 6746-0. System 8 System 8 ü www.nassmagnet.com ( +9 11 7-0 System 8 The name System 8 stands for a modular system of solenoid coils, armature systems, solenoid operators and solenoid valves. The diameter of the armatures

More information

Turbine Flow Sensor Series VTR

Turbine Flow Sensor Series VTR Turbine Flow Sensor Series VTR SIKA Turbine Flow Sensor Series VTR Extra robust, impressively precise SIKA s VTR turbine flow sensor allows you to determine precisely, dependably and easily the flow rates

More information

SITRANS F flowmeters SITRANS F M

SITRANS F flowmeters SITRANS F M Overview Integration The complete flowmeter consists of a flow sensor and an associated transmitter MAG 5000, 6000 or 6000 I. The flexible communication concept USM II simplifies integration and update

More information

8146/5 Series Breaker Panelboards

8146/5 Series Breaker Panelboards 8146/5 Series Breaker Panelboards DISTRIBUTION BREAKER PANELBOARDS FOR HAZARDOUS & CORROSIVE ENVIRONMENTS Breaker Panels Features: Wide variety of Flameproof branch circuit breakers for Zone 1 & Division

More information

www.kem-kueppers.com info@kem-kueppers.com Certified according to DIN EN ISO 9001 Technical Datasheet C-Flow Coriolis Mass Flow Meter

www.kem-kueppers.com info@kem-kueppers.com Certified according to DIN EN ISO 9001 Technical Datasheet C-Flow Coriolis Mass Flow Meter www.kem-kueppers.com info@kem-kueppers.com Certified according to DIN EN ISO 9001 Technical Datasheet C-Flow Coriolis Mass Flow Meter Description The coriolis mass flow meters measure simultaneously mass

More information

B-Series Temperature Switches

B-Series Temperature Switches FEATURES B-Series switches have proven reliable in such harsh environments as: Offshore oil rigs Chemical and petrochemical plants Pulp and paper mills Steel mills Power plants Water and sewage-treatment

More information

INDUSTRIAL CONTROL INSTRUMENTS FOR PROCESS AUTOMATION TOR REED SWITCH

INDUSTRIAL CONTROL INSTRUMENTS FOR PROCESS AUTOMATION TOR REED SWITCH INSTRUCTION MANUAL _ LEVEL SWITCH TOR REED SWITCH Type A B PC PP PF Magnetic level switch. Top mount directly in the tank. Up to 6 action thresholds. DESCRIPTION Level switch formed by: Housing (1) with

More information

Components for System Solutions E9/5. Ex d Enclosure System Made of Light Metal or Stainless Steel, "Flameproof Enclosure" Series 8264. www.stahl.

Components for System Solutions E9/5. Ex d Enclosure System Made of Light Metal or Stainless Steel, Flameproof Enclosure Series 8264. www.stahl. > Installation chamber can be fully used > Up to three mounting levels can be used > Saving of weight > Compact > Easy to combine > 26 enclosure versions > 15 window versions www.stahl.de 10303E00 The

More information

DSL-340 MkIII Double Pass Dust Monitor Measures 0-1000mg/m 3 using DDP

DSL-340 MkIII Double Pass Dust Monitor Measures 0-1000mg/m 3 using DDP Ideal for monitoring dust levels in the exhaust gas of industrial combustion or air filtration processes. Innovative Dynamic Detection Principle (DDP) measurement technique Immune to gradual reductions

More information

Ex Polyester Okta Box

Ex Polyester Okta Box - Glass fibre reinforced polyester enclosure system for applications in all Ex-areas - Empty enclosures for individual fittings and Ex e / Ex ia junction boxes - Enclosures with external fixing brackets

More information

System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter

System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter Application Used to convert a direct-current input signal into a pneumatic output signal for measuring and control

More information

Self-operated Temperature Regulators Temperature Regulator Type 1u

Self-operated Temperature Regulators Temperature Regulator Type 1u Self-operated Temperature Regulators Temperature Regulator Type u Application Temperature regulators for cooling installations Control thermostats for set points ) from 0 to 250 C G ½ to G or DN 5 to 50

More information

LEVEL GAUGES WITH MAGNETIC JOINT L 14 - L 22 - L 34

LEVEL GAUGES WITH MAGNETIC JOINT L 14 - L 22 - L 34 LEVEL GAUGES WITH MAGNETIC JOINT L 14 - L 22 - L 34 2 LEVEL GAUGES WITH MAGNETIC JOINT SIZE Ø 140/220/340 58 58 TYPE LA TYPE LA 14 30 S 22 33 TYPE LA 22-34 NO. HOLES Ø D2 76 O-RING CENTRE OF THE CONSERVATOR

More information

ISO/VDMA Actuators. Engineering GREAT Solutions

ISO/VDMA Actuators. Engineering GREAT Solutions ISO/VDMA Actuators Engineering GREAT Solutions 02 ISO/VDMA Actuators Contents 03 Introduction 04 ISO/VDMA Actuators 06 The ISO/VDMA Range 08 Industrial Options 10 Cleanline Options 12 IVAC innovation to

More information

2010-2011. Shortform Catalogue. Solutions for appliance & electronic applications. rocker switches. lever. switches. push. switches.

2010-2011. Shortform Catalogue. Solutions for appliance & electronic applications. rocker switches. lever. switches. push. switches. 2010-2011 Solutions for appliance & electronic applications Shortform Catalogue rocker lever push vandal resistant slide door snap-action & safety rotary IEC sockets fuseholders indicators A trading name

More information

Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS

Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS up to size 381; to PN 0.5; to T = 80 C 1. Description 1.1. General FSA fluid level gauges, FSK fluid level sensors and TS temperature

More information

AT500 Magnetostrictive Level Transmitter. Compact magnetostrictive liquid level transmitter for direct insertion K-TEK Products

AT500 Magnetostrictive Level Transmitter. Compact magnetostrictive liquid level transmitter for direct insertion K-TEK Products Data sheet DS/AT500-EN Rev. M AT500 Magnetostrictive Level Transmitter Compact magnetostrictive liquid level transmitter for direct insertion K-TEK Products Features Mounts from Top of Tank High Resolution

More information

Pendant Light Fittings Series 6050

Pendant Light Fittings Series 6050 > Saltwaterresistant enclosure, aluminium alloy, optionally with painting > Maintenancefree operation and long service life with induction lamp or LED > Mounting with ring bolts or tiltable mounting bracket

More information

Ammeter / Voltmeter Series 8402, 8403, 8405, 8404

Ammeter / Voltmeter Series 8402, 8403, 8405, 8404 /, 8403, 8405, 8404 > Fast comparison of measured with set values > s available, 8403 and 8402 www.stahl.de, 8403, 8405, 8404 10073E00 The ammeters and voltmeters from R. STAHL are explosion protected,

More information

3/2-way Solenoid Valve, direct-acting, NC or NO

3/2-way Solenoid Valve, direct-acting, NC or NO 3/2-way Solenoid Valve, direct-acting, NC or NO Electrical connection cable plug, Form A With or without manual override as standard Threaded port and sub-base s Impulse optional Type 6014 can be combined

More information

Ammeter / Voltmeter Series 8402, 8403, 8405, 8404

Ammeter / Voltmeter Series 8402, 8403, 8405, 8404 /, 8403, 8405, 8404 > Fast comparison of measured with set values > s available, 8403 and 8402 www.stahl.de, 8403, 8405, 8404 10073E00 The ammeters and voltmeters from R. STAHL are explosion protected,

More information

www.kem-kueppers.com info@kem-kueppers.com Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters

www.kem-kueppers.com info@kem-kueppers.com Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters www.kem-kueppers.com info@kem-kueppers.com Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters Description The Tricor Mass Flow Meters measure simultaneously mass

More information

Differential Pressure Sensor

Differential Pressure Sensor 1 921 1921P01 Differential Pressure Sensor for neutral and mildly corrosive liquids and gases QBE64-DP4 Differential pressure sensor, suitable for gases or liquids, for the measurement of positive or negative

More information

Plastic Flow Meters for gases & liquids, using TROGAMID* & POLYSULFONE Technology

Plastic Flow Meters for gases & liquids, using TROGAMID* & POLYSULFONE Technology Plastic Flow Meters for gases & liquids, using TROGAMID* & POYSUFONE Technology Applications Monitoring & Control of processes for: Water & Waste Water Treatment Chemical, Petrochemical & Paper Pharmaceutical,

More information

Electrical switch contacts

Electrical switch contacts Accessories Electrical switch contacts Model 8, magnetic snap-action contact Model 83, inductive contact Model 830 E, electronic contact Model 85, reed contact WIKA data sheet AC 08.0 Applications Control

More information

Cylinders DIN ISO 6431 and VDMA 24 562

Cylinders DIN ISO 6431 and VDMA 24 562 Double acting Standard executions Version Shape of barrel Symbol Type MAGNETIC STANDARD AMA AMT 1 For the magnetic reed switches type ASV see from page 1.110.1. For coupling cylinders/reed swiches/brackets

More information

COMBIMASS. Technical Data COMBIMASS eco-bio +

COMBIMASS. Technical Data COMBIMASS eco-bio + COMBIMASS Technical Data THE SYSTEM COMBIMASS The field transmitters of the COMBIMASS eco series are suitable for gas flow measurement and cover a wide range of different applications. The instruments

More information

3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve

3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve 3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve Type 6518 Type 6519 Type 6518/6519 can be combined with... Single or block mounting Suitable for outdoor and chemical atmospheres Suitable for

More information

INDUSTRIAL THERMOMETERS

INDUSTRIAL THERMOMETERS JJ SIKA thermometers for industry and marine sector JJ Special versions and accessories JJ SIKA thermometers for heating, air conditioning and ventilation (HVAC) INDUSTRIAL THERMOMETERS Contains products

More information

TAS ITA. DA1, dual csatlakozásfor thermostat. For control of 2 heaters on 1 thermostat. * * * * * * * * 41.729.220 Thermostat for CH 12/18

TAS ITA. DA1, dual csatlakozásfor thermostat. For control of 2 heaters on 1 thermostat. * * * * * * * * 41.729.220 Thermostat for CH 12/18 ACCESSORIES RT1, RT2, RT3 IT1 DA1 Thermostat for CH 12/18. Digital timer, burning and ventilating. Fault detector GSM. GSM temperature fault detector. THERMOSTATS RT1, room thermostat -10/+40 C with 5

More information

SEISMIC VELOCITY TRANSDUCER T1-40

SEISMIC VELOCITY TRANSDUCER T1-40 SEISMIC VELOCITY TRANSDUCER T1-40 Measurement of Omnidirectional Absolute Vibrations Certified according to ATEX 94/9/CE directive OPERATION Transducer T1-40 serves for seismic measurement of the absolute

More information

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics 3/2-, 5/2-5/3-way Solenoid Valves for process pneumatics Type 6518 stard High flow-rate capacity Reduced power consumption Single or manifold mounting stard Type 6518/6519 can be combined with... Stard-,

More information

24011 series, 3/2 Direct solenoid actuated poppet valve

24011 series, 3/2 Direct solenoid actuated poppet valve 0 series, / > > Port size: / (ISO G or NPT), NAMUR Interface > > Main application: Single and double acting actuators > > TÜV-approval based on type examination DGRL 97//EC and IEC 68, multichannel up

More information

www.kem-kueppers.com info@kem-kueppers.com Certified according to DIN EN ISO 9001 Technical Datasheet KVO Series Vortex Flow Meter

www.kem-kueppers.com info@kem-kueppers.com Certified according to DIN EN ISO 9001 Technical Datasheet KVO Series Vortex Flow Meter www.kem-kueppers.com Certified according to DIN EN ISO 9001 Technical Datasheet KVO Series Vortex Flow Meter Description The KVO Vortex flow meters utilize two primary sensing elements a vortex shedding

More information

Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx

Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx DSF..10.**.HV Ex ATEX Operating Instructions 374E-64368 Valid from lot nr. 0103 General Function Use in potentially explosive environment

More information

servo-controlled 3-WaY vacuum solenoid valves WiTH

servo-controlled 3-WaY vacuum solenoid valves WiTH servo-controlled 3-WaY vacuum solenoid s WiTH low absorption electric coil The 3-way vacuum solenoid s in this series feature two positions with pneumatically pilot-operated conical shutters. They can

More information

97300 NAMUR series, 3/2 & 5/2 Indirect solenoid actuated spool valve

97300 NAMUR series, 3/2 & 5/2 Indirect solenoid actuated spool valve 9700 NAMUR series, / & / > > Port size: G/, / NPT, NAMUR Interface > > Crossover-free switching > > Main application: Single and double acting actuators > > / way valve usable as / way valve > > Manual

More information

Technical data sheet TDS0070

Technical data sheet TDS0070 Technical data sheet TDS0070 ATEX Certified II 2 G Ex d IIC T4 Gb IECEx Certified Ex d IIC T4 Gb Ta = -20ºC to +60ºC FEATURES INCLUDE: - ATEX and IECEx Certified explosion proof Exd housing for Premier

More information

Inductive sensors. Compact, fast, reliable. Edition 2013

Inductive sensors. Compact, fast, reliable. Edition 2013 Inductive sensors. Compact, fast, reliable. Edition 2013 Indispensable in all machines Non-contacting, inductive proximity sensors play a major role in automation technology all over the world. For several

More information

Screw-in RTD temperature probe with plug connector according to DIN EN 175301

Screw-in RTD temperature probe with plug connector according to DIN EN 175301 ata sheet 902044 Page 1/8 Screw-in RT temperature probe with plug connector according to IN EN 175301 For temperatures between -50 and +260 C Vibration-resistant design Plug connector locked against contact,

More information

Scraper Passage Indicator. Electrical Indicator. Features

Scraper Passage Indicator. Electrical Indicator. Features IV Scraper Passage Indicator Bulletin No: 5110.001.03 Date: June 2008 Cross Indexing No: n/a Supersedes: 5110.001.02 (1/06) Flag Indicator Electrical Indicator Options Description TDW s IV Scraper Passage

More information

LMP 307. Stainless Steel Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % / 0.

LMP 307. Stainless Steel Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % / 0. LMP 07 Stainless Steel Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 % / 0. % FSO Nominal pressure from 0... mh O up to 0... 50 mh O Output signals -wire: 4... 0 ma -wire: 0...

More information

Miniature pushbutton switches

Miniature pushbutton switches Distinctive features and specifications Dry circuit through power ratings. ompact size. Panel, panel & P and P mounting models. ELETRIAL SPEIFIATIONS Max. current/voltage rating with resistive load : -

More information

Cable Plug acc. to DIN EN 175301-803, Form A

Cable Plug acc. to DIN EN 175301-803, Form A Cable Plug acc. to DIN EN 175301-803, Form A Complete program Contact form 18 mm Also available with LED indicator Optional 4-pin version for pressure switch or impulse valves respectively Versions with

More information

Solenoid Valve Island Type 3965

Solenoid Valve Island Type 3965 Solenoid Valve Island Type 365 for the control of pneumatic actuators General The Type 365 Solenoid Valve Island is a compact solution for the centralized control of pneumatic actuators in chemical and

More information

PCB transformers. Short circuit proof PCB transformer VB. General Data. Advantages. Applications. Circuit diagram. Standards & 1 Certifications W v

PCB transformers. Short circuit proof PCB transformer VB. General Data. Advantages. Applications. Circuit diagram. Standards & 1 Certifications W v Short circuit PCB transformer General Data Rated input 230 Vac Rated output 6-2 x 24 Vac Rated power 0.35-3.2 VA Insulation class B Maximum ambient temperature 70 C Efficiency up to 58 % Degree of protection

More information

Electrically operated valves Series M-05, 3/2-, 5/2- and 5/3-way G1/8 650 and 750 Nl/min (0.661 and 0.762 Cv)

Electrically operated valves Series M-05, 3/2-, 5/2- and 5/3-way G1/8 650 and 750 Nl/min (0.661 and 0.762 Cv) Electrically operated valves Series M-05, 3/2-, 5/2- and 5/3-way G1/8 650 and 750 Nl/min (0.661 and 0.762 Cv) Order code Series and function M-05-310-HN-442 Standard coil HN at ports 2 + 4 HN at ports

More information

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv) Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv) Order code Series and function 1) Plug socket see page 5.042. MN-06-310-HN-442 Standard coil 1) 441 = 12 V DC, 4.2 W 442 = 24 V DC,

More information

Electro-pneumatic control valves

Electro-pneumatic control valves Electropneumatic control valves 7 Miniature solenoid valves for alternating current Conform to the Low Voltage Directive or mounting on subbase or footprint in accordance with CNOMO recoendation E 066120N

More information

Operating Instructions

Operating Instructions Operating Instructions Cable Glands Ex d and Ex e with Compound > Contents 1 Contents 1 Contents...2 2 General Information...2 3 General Safety Information...3 4 Designated Use...4 5 Technical Data...4

More information

3 Way Proportional Pressure Control Valve Nominal diameter 2 Direct operated poppet valves Flange design Low hysteresis

3 Way Proportional Pressure Control Valve Nominal diameter 2 Direct operated poppet valves Flange design Low hysteresis VP0 Way Proportional Pressure Control Valve Nominal diameter Direct operated poppet valves Flange design Low hysteresis Good repeatability High flow capacity at exhaust port Manifold mountable system Compact

More information

Hose and Tube Fittings Series 1-3

Hose and Tube Fittings Series 1-3 Embracing Challenge Hose and Tube Fittings Series 1-3 out of plastics PP, PVDF, PTFE Series 1 Special Features Corrosion resistant Gas tight Easy to handle Different connection threads Application Hose

More information

MICRO SOLENOID VALVE pinch mechanism for flexible tube O.D. 1.65 to 9.5 mm

MICRO SOLENOID VALVE pinch mechanism for flexible tube O.D. 1.65 to 9.5 mm MICRO SOLENOID VALVE pinch mechanism for flexible tube O.D. 1.65 to 9.5 mm NC 2/2 Series 284 EATRES Solenoid valve suitable for cutting off the flow of a fluid by pinch or sterile, aseptic, physiological

More information

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points Features SELV Compliant No Detection Passive Injector Gigabit Compatible Full Protection

More information

Data sheet: Safety isolating transformers type APT

Data sheet: Safety isolating transformers type APT Data sheet: Safety isolating transformers type APT -------------------------- Description...: safety isolating transformer constructed and tested according to VDE 0570/EN 61 558 ; UL506 ; CSA 22.2 Test

More information

Compact pressure switch Flameproof enclosure Ex d Model PCA

Compact pressure switch Flameproof enclosure Ex d Model PCA Mechatronic pressure measurement Compact pressure switch Flameproof enclosure Ex d Model PCA WIKA data sheet PV 33.31 for further approvals see page 4 Process Compact Series Applications Pressure monitoring

More information

600, 630. Diaphragm Valve, Plastic

600, 630. Diaphragm Valve, Plastic Diaphragm Valve, Plastic Construction The /630 pneumatically operated 2/2-way valves have a low maintenance piston actuator which can be controlled by inert gaseous media. They have an integral optical

More information

Pressure Sensors. for neutral and slightly aggressive liquids and gases

Pressure Sensors. for neutral and slightly aggressive liquids and gases 1909P01 Pressure Sensors for neutral and slightly aggressive liquids and gases QBE2003-P QBE2103-P High-precision measuring Measuring range 0 to 60 bar relative Supply voltage AC 24 V / DC 12...33 V or

More information

3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve

3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve 3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve Type 6518 Type 6519 Type 6518/6519 can be combined with... Single or block mounting Suitable for outdoor and chemical atmospheres Suitable for

More information

Command devices Pull-wire emergency stop switches One-side operation ZS 71 range 6.1 6.1.1 6.1.1.1. 312 Schmersal -10 0 10 20 30 40 50 60 70 T [] C

Command devices Pull-wire emergency stop switches One-side operation ZS 71 range 6.1 6.1.1 6.1.1.1. 312 Schmersal -10 0 10 20 30 40 50 60 70 T [] C .1.1.1 One-side operation ZS 71 range 40 30 ø10 10 53,5(63)* 6 8 18 24 105 33 56 12 22 M20x1,5 52 17,5 42 15 Features To EN 418 / IEC 60947-5-5 Metal enclosure 2 contacts Small body 2 cable entries M20

More information

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm 0102 Model Number Features 5 mm flush Usable up to SIL 2 acc. to IEC 61508 Accessories EXG-18 Quick mounting bracket with dead stop BF 18 Mounting flange, 18 mm Technical Data specifications Switching

More information

RM/55401/M, Roundline cylinder Magnetic piston, double acting

RM/55401/M, Roundline cylinder Magnetic piston, double acting RM/550/M, Roundline cylinder > > Ø... 00 mm > > Clean line design > > ow friction, long life seals > > Standard magnetic piston for full control system versatility Technical features Medium: Compressed

More information

Cylinders Series 40. Double acting, cushioned, magnetic ø160-200 - 250 (DIN/ISO 6431)

Cylinders Series 40. Double acting, cushioned, magnetic ø160-200 - 250 (DIN/ISO 6431) Cylinders Series 40 Double acting, cushioned, magnetic ø60-200 - 250 (DIN/ISO 643)»»» DIN/ISO 643 VDMA 24562 Rolled stainless steel rod Adjustable cushioning The cylinders Series 40 with diameters 60,

More information

SICONT Limit Switches Type 3SE3 upto 500 VAC, 600 VDC, 10A

SICONT Limit Switches Type 3SE3 upto 500 VAC, 600 VDC, 10A s SICONT Limit Switches Type 3SE3 upto 500 VAC, 600 VDC, 10A Introduction The technical and descriptive information on the function, construction and selection of the new types of 3SE3 limit switches is

More information

Pressure monitoring equipment for oil-sf 6. bushings, type GOEK

Pressure monitoring equipment for oil-sf 6. bushings, type GOEK Pressure monitoring equipment for oil-sf 6 bushings, type GOEK Installation and maintenance guide 5693 827-6 en, Rev. 3, 2002-01-30 This document must not be copied without our written permission, and

More information

Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS

Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS Technical Information sheet 0001/07/Rev01 ENG FUNCTION Series S001 and S002 circulation units are applied to the primary circuit of solar

More information

Mechanical pressure switches

Mechanical pressure switches 18 Technical features / Advantages Diecast aluminium housing IP 54 or IP 65 version also available Wall mounting or directly on the pressure line Switching element (microswitch) Lead sealable setpoint

More information

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits RHE12 Hazardous Area Coriolis Mass Flow Transmitter Features Field mounting Compact, pressure safe housing ATEX and CSA approvals for installation in hazardous areas 24 VDC power supply Configurable analog

More information

e OLI Oil level indicator

e OLI Oil level indicator eoli Oil level indicator Oil level indicator eoli Unexpected or accidental oil leakages may occur randomly along transformer s lifetime. Clear indication of oil level inside transformer tank and on load

More information

Mobrey Hydrastep and Hydratect

Mobrey Hydrastep and Hydratect Product Data Sheet August 2015 BP2468, Rev EA Mobrey Hydrastep and Hydratect Water/Steam Monitoring Systems High clarity electronic gauging system for steam drums with options of local and remote indication

More information

RTD Temperature Probe for the Food/Pharmaceutical Industry

RTD Temperature Probe for the Food/Pharmaceutical Industry sales@jumo.co.uk Data Sheet 902810 Page 1/9 RTD Temperature Probe for the Food/Pharmaceutical Industry For temperatures between -50 and +250 C Protection type up to IP69 according to DIN EN 60529 (IP69K

More information

Switches SWITCHES SWITCHES

Switches SWITCHES SWITCHES Switches Manufactured from Stainless Steel, Bulgin s extensive range of vandal resistant security switches are designed with a high resistance to wear and tear, corrosion and harsh use in potentially hostile

More information

FILTER, REGULATOR AND FILTER/REGULATOR stainless steel 316L compact 1/4, high flow 1/4-1/2

FILTER, REGULATOR AND FILTER/REGULATOR stainless steel 316L compact 1/4, high flow 1/4-1/2 FILTER, REGULATOR AND FILTER/REGULATOR stainless steel L compact /, high flow / - / Air Preparation Series FEATURES Stainless Steel, and intended for corrosive environment and suitable for use in potentially

More information

Pendant Light Fitting IEC Series 6470

Pendant Light Fitting IEC Series 6470 > Available light sources highpressure sodium lamps (HSE) metal halide lamps (HIE) mercury lamps (HME) blended lamps (LME) halogen lamps (QT) > Versatile mounting methods > Enclosure made of saltwaterresistant

More information

Magnetic field sensor for pneumatic cylinders BIM-INT-Y1X-H1141

Magnetic field sensor for pneumatic cylinders BIM-INT-Y1X-H1141 ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Rectangular, height 6mm Plastic, PA12 Magnetic-inductive sensor DC 2-wire, nom. 8.2 VDC Output acc. to DIN EN 60947-5-6

More information

Datasheet DE44. 09005234 DB_EN_DE44_LCD Rev. ST4-A 07/16. Digital 2-channel differential pressure switch/transmitter with colour-change LCD *09005234*

Datasheet DE44. 09005234 DB_EN_DE44_LCD Rev. ST4-A 07/16. Digital 2-channel differential pressure switch/transmitter with colour-change LCD *09005234* 09005234 DB_EN_DE44_LCD Rev. ST4-A 07/16 *09005234* Datasheet DE44 Digital 2-channel differential pressure switch/transmitter with colour-change LCD 1 Product and functional description FISCHER Mess- und

More information

VARIABLE AREA FLOWMETER EASYFLOW.

VARIABLE AREA FLOWMETER EASYFLOW. VARIABLE AREA FLOWMETER EASYFLOW www.sedflowcontrol.com APPLICATIONS Monitoring of the flow of concentrate and recirculation of a reverse osmosis water treatment plant Reverse Osmosis System Water Treatment

More information