MGH Adult Diffusion Data Scanning Protocols
|
|
- Andrew O’Connor’
- 7 years ago
- Views:
Transcription
1 MGH Adult Diffusion Data Scanning Protocols Structural scans SIEMENS MAGNETOM ConnectomA syngo MR D11 \\USER\INVESTIGATORS\Default\AAHScout_64 TA:0:14 PAT:3 Voxel size: mm Rel. SNR:1.00 :fl Properties Prio Recon Before measurement After measurement Load to viewer Inline movie Auto store images Load to stamp segments Load images to graphic segments Auto open inline display Wait for user to start Start measurements single Routine Nr. of slab groups 1 Slabs 1 Dist. factor 20 % L0.0 A10.0 H0. Orientation Sagittal Slice oversampling 0.0 % FoV read 26 FoV phase % Slice thickness 1.6 mm TR 3.15 ms TE 1.37 ms Averages 1 Concatenations 1 Filter Head Contrast Flip angle 8 deg Short term Measurements 1 Reconstruction Magnitude Resolution Base resolution 160 Phase resolution 100 % Phase partial Fourier 6/8 PAT mode GRAPPA Accel. factor PE 3
2 Ref. lines PE 24 Reference scan mode Integrated Image Filter Accel. factor 3D 1 Unfiltered images Normalize B1 filter Raw filter Elliptical filter Slice resolution 69 % Slice partial Fourier 6/8 Geometry Nr. of slab groups 1 Slabs 1 Dist. factor 20 % L0.0 A10.0 H0. Slice oversampling 0.0 % Slices per slab 128 Sequential Series Ascending Nr. of sat. regions 0 mode P System Body TOP BOT mode ing mode REF H MSMA S - C - T Sagittal Coronal Transversal Save uncombined Coil Combine Mode Adaptive Combine Auto Coil Select Default Shim mode Tune up Adjust with body coil Confirm freq. adjustment Assume Dominant Fat Assume Silicone Adjustment Tolerance Auto? Ref. amplitude 1H V Isocenter Rotation 0.00 deg mm
3 35 Frequency 1H MHz Correction factor 1 SRFExcit 1H V Gain Low Img. Scale. Cor Physio Inline Distortion correction Sequence Introduction Dimension 3D Short term Sequential Asymmetric echo Weak Contrasts 1 Bandwidth 54/Px RF pulse type Fast Gradient mode Normal Excitation Non-sel. RF spoiling TX/RX delta frequency TX Nucleus TX delta frequency Acquisition duration Mode BOLD Time to center 6.2 s Subtract Save images Autoscaling Scaling factor 1 set 0 Subtrahend 1 Subtraction indices StdDev Std-Dev-Sag Std-Dev-Cor Std-Dev-Tra Std-Dev-Time MIP-Sag MIP-Cor MIP-Tra MIP-Time Radial MIP Save original images Contrasts 1 Save original images Number of radial views 1 Axis of radial views L-R MPR Sag
4 MPR Cor MPR Tra SIEMENS MAGNETOM ConnectomA syngo MR D11 \\USER\INVESTIGATORS\Default\MEMPRAGE_pat2 TA:6:02 PAT:2 Voxel size: Rel. SNR:1.00 :tfl_me Properties Prio Recon Before measurement After measurement Load to viewer Inline movie Auto store images Load to stamp segments Load images to graphic segments Auto open inline display Wait for user to start Start measurements single Routine Nr. of slab groups 1 Slabs 1 Dist. factor 50 % R0.8 P18.4 F16.7 mm Orientation Sagittal Head > Basis Slice oversampling 0.0 % FoV read 256 mm FoV phase % Slice thickness 1.0 TR TE ms Averages 1 Concatenations 1 Filter Contrast Non-sel. IR TI 110 Flip angle 7.0 deg Water suppr. Long term Measurements 1 Reconstruction Magnitude Multiple series Each measurement Resolution Base resolution 256
5 Phase resolution 100 % Phase partial Fourier Interpolation PAT mode GRAPPA Accel. factor PE 2 Ref. lines PE 32 Reference scan mode Integrated Image Filter Accel. factor 3D 1 Unfiltered images Normalize B1 filter Raw filter Elliptical filter Slice resolution 100 % Slice partial Fourier Geometry Nr. of slab groups 1 Slabs 1 Dist. factor 50 % R0.8 P18.4 F16.7 mm Slice oversampling 0.0 % Slices per slab 176 Single shot Series Nr. of sat. regions 0 mode Water suppr. P System Body TOP BOT mode ing mode REF H MSMA S - C - T Sagittal Coronal Transversal Save uncombined Coil Combine Mode Adaptive Combine Head > Basis Auto Coil Select Default Shim mode Standard Adjust with body coil Confirm freq. adjustment
6 Assume Dominant Fat Assume Silicone Adjustment Tolerance Auto? Ref. amplitude 1H V R0.8 P18.4 F16.7 mm Rotation 0.00 deg 256 mm 256 mm 176 mm Frequency 1H MHz Correction factor 1 SLoopIRns1 1H V Gain Low Img. Scale. Cor Physio 1st Signal/Mode Non-sel. IR TI 110 Dark blood Resp. control Inline Distortion correction Sequence Introduction Dimension 3D Elliptical scanning Long term Single shot Reordering Linear Asymmetric echo Allowed Contrasts 4 Bandwidth Hz/Px Flow comp. 1 No Echo spacing 9.4 ms Turbo factor 176 RF pulse type Fast Gradient mode Fast Excitation Non-sel. RF spoiling Readout polarity Positive Readout trajectory Bipolar Add. scale factor 2.0 Gradient spoiling Integral Gradient moment factor 3.0 Siemens reconstruction Save raw k-space data Averaging RMS TX/RX delta frequency TX Nucleus TX delta frequency Acquisition duration Mode
7 BOLD Subtract Save images Autoscaling Scaling factor 1 set 0 Subtrahend 1 Subtraction indices StdDev Std-Dev-Sag Std-Dev-Cor Std-Dev-Tra Std-Dev-Time MIP-Sag MIP-Cor MIP-Tra MIP-Time Radial MIP Save original images Contrasts 4 Save original images Number of radial views 1 Axis of radial views L-R MPR Sag MPR Cor MPR Tra SIEMENS MAGNETOM ConnectomA syngo MR D11 \\USER\INVESTIGATORS\Default\t2_spc_WashU_Connectome_0p7iso TA:6:48 PAT:2 Voxel size: mm Rel. SNR:1.00 :spc Properties Prio Recon Before measurement After measurement Load to viewer Inline movie Auto store images Load to stamp segments Load images to graphic segments Auto open inline display Wait for user to start Start measurements single Routine Nr. of slab groups 1 Slabs 1 R0.8 P18.4 F16.7 mm Orientation Sagittal Head > Basis
8 Phase oversampling 10 % Slice oversampling 0.0 % FoV read 224 mm FoV phase % Slice thickness 0.7 TR 320 TE 561. Concatenations 1 Filter Raw filter, Prescan Normalize Contrast MTC Water suppr. Restore magn. Measurements 1 Reconstruction Magnitude Multiple series Each measurement Resolution Base resolution 320 Phase resolution 100 % Phase partial Fourier Allowed Interpolation PAT mode GRAPPA Accel. factor PE 2 Ref. lines PE 32 Reference scan mode Integrated Image Filter Accel. factor 3D 1 Unfiltered images Normalize B1 filter Raw filter Intensity Weak Slope 25 Elliptical filter Slice resolution 80 % Slice partial Fourier Geometry Nr. of slab groups 1 Slabs 1 R0.8 P18.4 F16.7 mm Phase oversampling 10 % Slice oversampling 0.0 % Slices per slab 256 Series Nr. of sat. regions 0 mode
9 Water suppr. P Restore magn. System Body TOP BOT mode ing mode FIX H MSMA S - C - T Sagittal Coronal Transversal Save uncombined Coil Combine Mode Adaptive Combine Head > Basis Auto Coil Select Shim mode Standard Adjust with body coil Confirm freq. adjustment Assume Dominant Fat Assume Silicone Adjustment Tolerance Auto? Ref. amplitude 1H V R0.8 P18.4 F16.7 mm Rotation 0.00 deg 224 mm 224 mm 18 Frequency 1H MHz Correction factor 1 SRFExcit 1H V! Gain High Img. Scale. Cor Physio 1st Signal/Mode Trigger delay Dark blood Resp. control Inline Distortion correction Sequence Introduction Dimension 3D Elliptical scanning Reordering Linear Bandwidth 744 Hz/Px Flow comp. No
10 BOLD Allowed delay 30 s Echo spacing 3.55 ms Adiabatic-mode Turbo factor 314 Echo train duration 1111 RF pulse type Normal Gradient mode Fast Excitation Non-sel. Flip angle mode T2 var TX/RX delta frequency TX Nucleus TX delta frequency Acquisition duration Organ under exam. Subtract Save images Autoscaling Scaling factor 1 set 0 Subtrahend 1 Subtraction indices StdDev Std-Dev-Sag Std-Dev-Cor Std-Dev-Tra Std-Dev-Time MIP-Sag MIP-Cor MIP-Tra MIP-Time Radial MIP Save original images Save original images Number of radial views 1 Axis of radial views L-R MPR Sag MPR Cor MPR Tra
11 Diffusion scans SIEMENS MAGNETOM ConnectomA syngo MR D11 \\USER\INVESTIGATORS\Default\ep2d_diff_qb64_b1k TA:11:44 PAT:3 Voxel size: mm Rel. SNR:1.00 :epse Properties Prio Recon Before measurement After measurement Load to viewer Inline movie Auto store images Load to stamp segments Load images to graphic segments Auto open inline display Wait for user to start Start measurements single Routine Nr. of slice groups 1 Slices 96 Dist. factor 0 % Orientation T > C-25.0 Head > Brain FoV read FoV phase % Slice thickness 1.5 mm TR 880 TE 57. Averages 1 Concatenations 1 Filter Contrast MTC Fat sat. Fat sat. mode Strong Long term Delay in TR Reconstruction Magnitude Multiple series Resolution Base resolution 140 Phase resolution 100 % Phase partial Fourier 6/8 Interpolation PAT mode GRAPPA
12 Accel. factor PE 3 Ref. lines PE 84 Reference scan mode Separate Normalize Raw filter Elliptical filter Dynamic Field Corr. Geometry Nr. of slice groups 1 Slices 96 Dist. factor 0 % Series Nr. of sat. regions 0 mode Fat sat. Fat sat. mode Strong P System Body TOP BOT mode ing mode FIX H MSMA S - C - T Sagittal Coronal Transversal Coil Combine Mode Adaptive Combine Head > Brain Auto Coil Select Default Shim mode Standard Adjust with body coil Confirm freq. adjustment Assume Dominant Fat Assume Silicone Adjustment Tolerance Auto? Ref. amplitude 1H V Rotation 0.00 deg 144 mm Frequency 1H MHz Correction factor 1
13 ACS SincRFPulse 1H V Gain High Img. Scale. Cor Physio 1st Signal/Mode Resp. control Inline Distortion correction Sequence Introduction Long term Bandwidth 1984 Hz/Px Optimization Free echo spacing Echo spacing 0.63 ms EPI factor 140 RF pulse type Low SAR Gradient mode Fast Directions HCP_xc_64_cnst Preparation 1 TRs Init. Low-B Reps 1 Dynamic B0 Correction Complex Coil Combine Grad Min Rise 1.m/T Max Diff Grad 243 mt/m RO/PE Grads Standard Auto-scale images RO ramp sampling Force segmented ACS TX/RX delta frequency TX Nucleus TX delta frequency Acquisition duration BOLD Delay in TR Diffusion mode Free Diff. weightings 2 b-value 1 0 s/mm² Diff. weighted images Trace weighted images ADC maps FA maps Mosaic Tensor b-value >= 0 s/mm² Exponential ADC Maps Invert Gray Scale Calculated Image
14 SIEMENS MAGNETOM ConnectomA syngo MR D11 \\USER\INVESTIGATORS\Default\ep2d_diff_qb64_b3k TA:11:44 PAT:3 Voxel size: mm Rel. SNR:1.00 :epse Properties Prio Recon Before measurement After measurement Load to viewer Inline movie Auto store images Load to stamp segments Load images to graphic segments Auto open inline display Wait for user to start Start measurements single Routine Nr. of slice groups 1 Slices 96 Dist. factor 0 % Orientation T > C-25.0 Head > Brain FoV read FoV phase % Slice thickness 1.5 mm TR 880 TE 57. Averages 1 Concatenations 1 Filter Contrast MTC Fat sat. Fat sat. mode Strong Long term Delay in TR Reconstruction Magnitude Multiple series Resolution Base resolution 140 Phase resolution 100 % Phase partial Fourier 6/8 Interpolation PAT mode GRAPPA Accel. factor PE 3 Ref. lines PE 84
15 Reference scan mode Separate Normalize Raw filter Elliptical filter Dynamic Field Corr. Geometry Nr. of slice groups 1 Slices 96 Dist. factor 0 % Series Nr. of sat. regions 0 mode Fat sat. Fat sat. mode Strong P System Body TOP BOT mode ing mode FIX H MSMA S - C - T Sagittal Coronal Transversal Coil Combine Mode Adaptive Combine Head > Brain Auto Coil Select Default Shim mode Standard Adjust with body coil Confirm freq. adjustment Assume Dominant Fat Assume Silicone Adjustment Tolerance Auto? Ref. amplitude 1H V Rotation 0.00 deg 144 mm Frequency 1H MHz Correction factor 1 ACS SincRFPulse 1H V Gain High
16 Img. Scale. Cor Physio 1st Signal/Mode Resp. control Inline Distortion correction Sequence Introduction Long term Bandwidth 1984 Hz/Px Optimization Free echo spacing Echo spacing 0.63 ms EPI factor 140 RF pulse type Low SAR Gradient mode Fast Directions HCP_xc_64_cnst Preparation 1 TRs Init. Low-B Reps 1 Dynamic B0 Correction Complex Coil Combine Grad Min Rise 1.m/T Max Diff Grad 243 mt/m RO/PE Grads Standard Auto-scale images RO ramp sampling Force segmented ACS TX/RX delta frequency TX Nucleus TX delta frequency Acquisition duration BOLD Delay in TR Diffusion mode Free Diff. weightings 2 b-value 1 0 s/mm² Diff. weighted images Trace weighted images ADC maps FA maps Mosaic Tensor b-value >= 0 s/mm² Exponential ADC Maps Invert Gray Scale Calculated Image
17 SIEMENS MAGNETOM ConnectomA syngo MR D11 \\USER\INVESTIGATORS\Default\ep2d_diff_qb128_b5k TA:21:51 PAT:3 Voxel size: mm Rel. SNR:1.00 :epse Properties Prio Recon Before measurement After measurement Load to viewer Inline movie Auto store images Load to stamp segments Load images to graphic segments Auto open inline display Wait for user to start Start measurements single Routine Nr. of slice groups 1 Slices 96 Dist. factor 0 % Orientation T > C-25.0 Head > Brain FoV read FoV phase % Slice thickness 1.5 mm TR 880 TE 57. Averages 1 Concatenations 1 Filter Contrast MTC Fat sat. Fat sat. mode Strong Long term Delay in TR Reconstruction Magnitude Multiple series Resolution Base resolution 140 Phase resolution 100 % Phase partial Fourier 6/8 Interpolation PAT mode GRAPPA Accel. factor PE 3 Ref. lines PE 84
18 Reference scan mode Separate Normalize Raw filter Elliptical filter Dynamic Field Corr. Geometry Nr. of slice groups 1 Slices 96 Dist. factor 0 % Series Nr. of sat. regions 0 mode Fat sat. Fat sat. mode Strong P System Body TOP BOT mode ing mode FIX H MSMA S - C - T Sagittal Coronal Transversal Coil Combine Mode Adaptive Combine Head > Brain Auto Coil Select Default Shim mode Standard Adjust with body coil Confirm freq. adjustment Assume Dominant Fat Assume Silicone Adjustment Tolerance Auto? Ref. amplitude 1H V Rotation 0.00 deg 144 mm Frequency 1H MHz Correction factor 1 ACS SincRFPulse 1H V Gain High
19 Img. Scale. Cor Physio 1st Signal/Mode Resp. control Inline Distortion correction Sequence Introduction Long term Bandwidth 1984 Hz/Px Optimization Free echo spacing Echo spacing 0.63 ms EPI factor 140 RF pulse type Low SAR Gradient mode Fast Directions HCP_xc_128_cnst Preparation 1 TRs Init. Low-B Reps 1 Dynamic B0 Correction Complex Coil Combine Grad Min Rise 1.m/T Max Diff Grad 243 mt/m RO/PE Grads Standard Auto-scale images RO ramp sampling Force segmented ACS TX/RX delta frequency TX Nucleus TX delta frequency Acquisition duration BOLD Delay in TR Diffusion mode Free Diff. weightings 2 b-value 1 0 s/mm² Diff. weighted images Trace weighted images ADC maps FA maps Mosaic Tensor b-value >= 0 s/mm² Exponential ADC Maps Invert Gray Scale Calculated Image
20 SIEMENS MAGNETOM ConnectomA syngo MR D11 \\USER\INVESTIGATORS\Default\ep2d_diff_qb128_b10k_set1 TA:21:51 PAT:3 Voxel size: mm Rel. SNR:1.00 :epse Properties Prio Recon Before measurement After measurement Load to viewer Inline movie Auto store images Load to stamp segments Load images to graphic segments Auto open inline display Wait for user to start Start measurements single Routine Nr. of slice groups 1 Slices 96 Dist. factor 0 % Orientation T > C-25.0 Head > Brain FoV read FoV phase % Slice thickness 1.5 mm TR 880 TE 57. Averages 1 Concatenations 1 Filter Contrast MTC Fat sat. Fat sat. mode Strong Long term Delay in TR Reconstruction Magnitude Multiple series Resolution Base resolution 140 Phase resolution 100 % Phase partial Fourier 6/8 Interpolation PAT mode GRAPPA Accel. factor PE 3 Ref. lines PE 84
21 Reference scan mode Separate Normalize Raw filter Elliptical filter Dynamic Field Corr. Geometry Nr. of slice groups 1 Slices 96 Dist. factor 0 % Series Nr. of sat. regions 0 mode Fat sat. Fat sat. mode Strong P System Body TOP BOT mode ing mode FIX H MSMA S - C - T Sagittal Coronal Transversal Coil Combine Mode Adaptive Combine Head > Brain Auto Coil Select Default Shim mode Standard Adjust with body coil Confirm freq. adjustment Assume Dominant Fat Assume Silicone Adjustment Tolerance Auto? Ref. amplitude 1H V Rotation 0.00 deg 144 mm Frequency 1H MHz Correction factor 1 ACS SincRFPulse 1H V Gain High
22 Img. Scale. Cor Physio 1st Signal/Mode Resp. control Inline Distortion correction Sequence Introduction Long term Bandwidth 1984 Hz/Px Optimization Free echo spacing Echo spacing 0.63 ms EPI factor 140 RF pulse type Low SAR Gradient mode Fast Directions HCP_xc_128_cnst Preparation 1 TRs Init. Low-B Reps 1 Dynamic B0 Correction Complex Coil Combine Grad Min Rise 1.m/T Max Diff Grad 243 mt/m RO/PE Grads Standard Auto-scale images RO ramp sampling Force segmented ACS TX/RX delta frequency TX Nucleus TX delta frequency Acquisition duration BOLD Delay in TR Diffusion mode Free Diff. weightings 2 b-value 1 0 s/mm² Diff. weighted images Trace weighted images ADC maps FA maps Mosaic Tensor b-value >= 0 s/mm² Exponential ADC Maps Invert Gray Scale Calculated Image
23 SIEMENS MAGNETOM ConnectomA syngo MR D11 \\USER\INVESTIGATORS\Default\ep2d_diff_qb128_b10k_set2 TA:21:51 PAT:3 Voxel size: mm Rel. SNR:1.00 :epse Properties Prio Recon Before measurement After measurement Load to viewer Inline movie Auto store images Load to stamp segments Load images to graphic segments Auto open inline display Wait for user to start Start measurements single Routine Nr. of slice groups 1 Slices 96 Dist. factor 0 % Orientation T > C-25.0 Head > Brain FoV read FoV phase % Slice thickness 1.5 mm TR 880 TE 57. Averages 1 Concatenations 1 Filter Contrast MTC Fat sat. Fat sat. mode Strong Long term Delay in TR Reconstruction Magnitude Multiple series Resolution Base resolution 140 Phase resolution 100 % Phase partial Fourier 6/8 Interpolation PAT mode GRAPPA Accel. factor PE 3 Ref. lines PE 84 Reference scan mode Separate
24 Normalize Raw filter Elliptical filter Dynamic Field Corr. Geometry Nr. of slice groups 1 Slices 96 Dist. factor 0 % Series Nr. of sat. regions 0 mode Fat sat. Fat sat. mode Strong P System Body TOP BOT mode ing mode FIX H MSMA S - C - T Sagittal Coronal Transversal Coil Combine Mode Adaptive Combine Head > Brain Auto Coil Select Default Shim mode Standard Adjust with body coil Confirm freq. adjustment Assume Dominant Fat Assume Silicone Adjustment Tolerance Auto? Ref. amplitude 1H V Rotation 0.00 deg 144 mm Frequency 1H MHz Correction factor 1 ACS SincRFPulse 1H V Gain High
25 Img. Scale. Cor Physio 1st Signal/Mode Resp. control Inline Distortion correction Sequence Introduction Long term Bandwidth 1984 Hz/Px Optimization Free echo spacing Echo spacing 0.63 ms EPI factor 140 RF pulse type Low SAR Gradient mode Fast Directions HCP_xc_alt_128_cnst Preparation 1 TRs Init. Low-B Reps 1 Dynamic B0 Correction Complex Coil Combine Grad Min Rise 1.m/T Max Diff Grad 243 mt/m RO/PE Grads Standard Auto-scale images RO ramp sampling Force segmented ACS TX/RX delta frequency TX Nucleus TX delta frequency Acquisition duration BOLD Delay in TR Diffusion mode Free Diff. weightings 2 b-value 1 0 s/mm² Diff. weighted images Trace weighted images ADC maps FA maps Mosaic Tensor b-value >= 0 s/mm² Exponential ADC Maps Invert Gray Scale Calculated Image
32-Channel Head Coil Imaging at 3T
32-Channel Head Coil Imaging at 3T Thomas Benner Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital and Harvard Medical School, Boston, MA, USA
More informationGE Medical Systems Training in Partnership. Module 8: IQ: Acquisition Time
Module 8: IQ: Acquisition Time IQ : Acquisition Time Objectives...Describe types of data acquisition modes....compute acquisition times for 2D and 3D scans. 2D Acquisitions The 2D mode acquires and reconstructs
More informationMusculoskeletal MRI Technical Considerations
Musculoskeletal MRI Technical Considerations Garry E. Gold, M.D. Professor of Radiology, Bioengineering and Orthopaedic Surgery Stanford University Outline Joint Structure Image Contrast Protocols: 3.0T
More informationGE 3.0T NPW,TRF,FAST,F R NPW,TRF,FAST,F R
GE 3.0T 3.0T WRIST Invivo 8CH Wrist Coil Sequence Ax T2 Cor PD Cor PDFS Cor T1 Cor PD (Small FOV) FOV (mm) 80 80 80 80 40 Matrix 384x224 384x256 320x256 384x320 320x192 Phase Direction RL RL RL RL RL #
More informationSITE IMAGING MANUAL ACRIN 6698
SITE IMAGING MANUAL ACRIN 6698 Diffusion Weighted MR Imaging Biomarkers for Assessment of Breast Cancer Response to Neoadjuvant Treatment: A sub-study of the I-SPY 2 TRIAL Version: 1.0 Date: May 28, 2012
More informationToshiba Excelart Vantage 1.5T MRI Tech Specs (Technical Specifications)
Toshiba Excelart Vantage 1.5T MRI Tech Specs (Technical Specifications) Excelart Vantage Magnet Configuration: Ultra-short-bore Strength (or W x H): 1.5 T Homogeneity, ppm V-RMS: Dimensions of maximum
More information5 Factors Affecting the Signal-to-Noise Ratio
5 Factors Affecting the Signal-to-Noise Ratio 29 5 Factors Affecting the Signal-to-Noise Ratio In the preceding chapters we have learned how an MR signal is generated and how the collected signal is processed
More informationGE Medical Systems Training in Partnership. Module 12: Spin Echo
Module : Spin Echo Spin Echo Objectives Review the SE PSD. Review the concepts of T, T, and T*. Spin Echo PSD RF Gz Gy 90 80 Gx Spin Echo - SE Spin echo is a standard pulse sequence on Signa MRi/LX and
More informationCirrus 0.2T. MRI for Everyone. North America, Asia, Europe. contact: kturek@mri-tech.pl
Cirrus 0.2T MRI for Everyone North America, Asia, Europe contact: kturek@mri-tech.pl MRI-TECH inc. Cirrus MRI system for all your needs: Low costs Low maintenance High quality Open geometry Imaging of
More informationKap 8 Image quality, signal, contrast and noise
4/5/ FYS-KJM 474 contrast SNR MR-teori og medisinsk diagnostikk Kap 8 Image qualit, signal, contrast and noise resolution vailable MRparameters speed Main source of noise in MRI: Noise generated within
More informationConfiguration and Use of the MR Knee Dot Engine
Configuration and Use of the MR Knee Dot Engine Kai Reiter (RT); Sebastian Auer (RT) Radiology Herne, Herne, Germany 1 42 MAGNETOM Flash 3/2011 www.siemens.com/magnetom-world We are a radiological joint
More information3/30/2013. Disclosure. Advanced Neuro MRI: Imaging Techniques and Protocol Optimization. MRI, 35 year ago. MRI Today. Outlines
http://www.magnet.fsu.edu Disclosure Advanced Neuro MRI: Imaging Techniques and Protocol Optimization Research funding provided by Siemens Healthcare. Chen Lin, PhD DABR Indiana University School of Medicine
More informationMRI SEQUENCES. 1 Gradient Echo Sequence
5 An MRI sequence is an ordered combination of RF and gradient pulses designed to acquire the data to form the image. In this chapter I will describe the basic gradient echo, spin echo and inversion recovery
More informationParaVision 6. Innovation with Integrity. The Next Generation of MR Acquisition and Processing for Preclinical and Material Research.
ParaVision 6 The Next Generation of MR Acquisition and Processing for Preclinical and Material Research Innovation with Integrity Preclinical MRI A new standard in Preclinical Imaging ParaVision sets a
More informationCOST AID ASL post- processing Workshop
COST AID ASL post- processing Workshop This workshop runs thought the post- processing of ASL data using tools from the FMRIB Software Library (www.fmrib.ox.ac.uk.uk/fsl), we will primarily focus on the
More informationMedical Imaging. MRI Instrumentation, Data Acquisition, Image Reconstruction. Assistant Professor Department of Radiology, NYU School of Medicine
G16.4426/EL5823/BE6203 Medical Imaging MRI Instrumentation, Data Acquisition, Image Reconstruction Riccardo Lattanzi, Ph.D. Assistant Professor Department of Radiology, NYU School of Medicine Department
More informationMRI DATA PROCESSING. Compiled by: Nicolas F. Lori and Carlos Ferreira. Introduction
MRI DATA PROCESSING Compiled by: Nicolas F. Lori and Carlos Ferreira Introduction Magnetic Resonance Imaging (MRI) is a clinical exam that is safe to the patient. Nevertheless, it s very important to attend
More informationOverview. Optimizing MRI Protocols. Image Contrast. Morphology & Physiology. User Selectable Parameters. Tissue Parameters
Overview Optimizing MRI Protocols Clinical Practice & Compromises Geoffrey D. Clarke, Radiology Department University of Texas Health Science Center at San Antonio Pulse timing parameters for adjusting
More informationLONI De-Identification Policy
The following defines how different file formats are de-identified with LONI tools. Each metadata attribute of each file can have the following operations performed: Operation keep Remove Replace Description
More informationBasic Principles of Magnetic Resonance
Basic Principles of Magnetic Resonance Contents: Jorge Jovicich jovicich@mit.edu I) Historical Background II) An MR experiment - Overview - Can we scan the subject? - The subject goes into the magnet -
More informationHigh Spatial Resolution EPI Using an Odd Number of Interleaves
Magnetic Resonance in Medicine 41:1199 1205 (1999) High Spatial Resolution EPI Using an Odd Number of Interleaves Michael H. Buonocore* and David C. Zhu Ghost artifacts in echoplanar imaging (EPI) arise
More information7/16/2010. Pulse Sequences and Acquisition Techniques for Breast MRI. Objectives. ACR Breast MRI Accreditation Program Launched May 2010
Pulse Sequences and Acquisition Techniques for Breast MRI ACR Breast MRI Accreditation Program Launched May 2010 Ron Price Vanderbilt University Medical Center Nashville, TN 37232 Information available:
More informationGeneration and Detection of NMR Signals
Generation and Detection of NMR Signals Hanudatta S. Atreya NMR Research Centre Indian Institute of Science NMR Spectroscopy Spin (I)=1/2h B 0 Energy 0 = B 0 Classical picture (B 0 ) Quantum Mechanical
More informationDiffusione e perfusione in risonanza magnetica. E. Pagani, M. Filippi
Diffusione e perfusione in risonanza magnetica E. Pagani, M. Filippi DW-MRI DIFFUSION-WEIGHTED MRI Principles Diffusion results from a microspic random motion known as Brownian motion THE RANDOM WALK How
More informationImpedance 50 (75 connectors via adapters)
VECTOR NETWORK ANALYZER PLANAR TR1300/1 DATA SHEET Frequency range: 300 khz to 1.3 GHz Measured parameters: S11, S21 Dynamic range of transmission measurement magnitude: 130 db Measurement time per point:
More informationrunl I IUI%I/\L Magnetic Resonance Imaging
runl I IUI%I/\L Magnetic Resonance Imaging SECOND EDITION Scott A. HuetteS Brain Imaging and Analysis Center, Duke University Allen W. Song Brain Imaging and Analysis Center, Duke University Gregory McCarthy
More information7/22/2011. Breast MRI: Pulse Sequences, Acquisition Protocols, and Analysis. Objectives. Challenges in DCE Breast Imaging
Breast MRI: Pulse Sequences, Acquisition Protocols, and Analysis Objectives Ron Price Vanderbilt University Medical Center Nashville, TN 37232 1. Review background of MRI breast cancer imaging 2. Present
More informationBreast MRI Quality Control
Donna M. Reeve, MS, DABR, DABMP Department of Imaging Physics Educational Objectives Discuss the importance of breast MRI quality control (QC). Provide an overview of the new ACR Breast MRI Accreditation
More informationNEURO MRI PROTOCOLS TABLE OF CONTENTS
TABLE OF CONTENTS NEURO MRI PROTOCOLS BRAIN...2 Brain 1 Screen... 2 Brain 2 Brain Tumor... 2 Brain 3 Brain Infection / Meningitis... 2 Brain 4 Trauma... 3 Brain 5 Hemorrhage... 3 Brain 6 Demyelinating
More informationNMR Techniques Applied to Mineral Oil, Water, and Ethanol
NMR Techniques Applied to Mineral Oil, Water, and Ethanol L. Bianchini and L. Coffey Physics Department, Brandeis University, MA, 02453 (Dated: February 24, 2010) Using a TeachSpin PS1-A pulsed NMR device,
More informationClinical applications of MRI in radiation therapy. Jatta Berberat, PhD Kantonsspital Aarau jatta.berberat@ksa.ch
Clinical applications of MRI in radiation therapy Jatta Berberat, PhD Kantonsspital Aarau jatta.berberat@ksa.ch Background and introduction Magnetic Resonance Imaging Relaxation mechanisms Imaging gradients
More informationPrinciples of functional Magnetic Resonance Imaging
1 Principles of functional Magnetic Resonance Imaging Martin A. Lindquist Department of Biostatistics; Johns Hopkins University Tor D. Wager Department of Psychology & Neuroscience; University of Colorado
More informationElectronic Supplementary Information
Electronic Supplementary Material (ESI) for Physical Chemistry Chemical Physics. This journal is the Owner Societies 2016 Electronic Supplementary Information Achieving High Resolution and Controlling
More informationTechnical Datasheet Scalar Network Analyzer Model 8003-10 MHz to 40 GHz
Technical Datasheet Scalar Network Analyzer Model 8003-10 MHz to 40 GHz The Giga-tronics Model 8003 Precision Scalar Network Analyzer combines a 90 db wide dynamic range with the accuracy and linearity
More informationSpectrum Analyzer. Software Instruction Manual
Spectrum Analyzer Software Instruction Manual 700 Chestnut Ridge Road Chestnut Ridge, NY, 10977-6499 Tel: (845) 425-4000 Fax: (845) 578 5985 teledynelecroy.com Spectrum Analyzer Software Instruction Manual
More informationIt takes two to connect the dots in MRI.
It takes two to connect the dots in MRI. www.siemens.com/healthcare Tim+ Tim (Total imaging matrix) technology has made fast, flexible and accurate scans the rule, rather than the exception. But we know
More informationEtude POPART'MUS MRI Component
TECHNICAL SURVEY Dear Investigators, This document is a Technical Survey which provides the teams of THERALYS and of the Pierre Wertheimer Neurological Hospital of Lyon with an overview of your site s
More informationChapter 2 NMR in Inhomogeneous Fields
Chapter 2 NMR in Inhomogeneous Fields Federico Casanova and Juan Perlo 2.1 Introduction Besides the redesigning of the hardware to excite and detect NMR signals from sample volumes external to the sensor,
More informationwww.siemens.com/skyra Image Gallery MAGNETOM Skyra Answers for life.
www.siemens.com/skyra Image Gallery MAGNETOM Skyra Answers for life. Clinical excellence, consistently. With Tim+Dot. Tim 4G (Total imaging matrix) Technology Dot (Day optimizing throughput) Engine Tim
More informationMedical Image Processing on the GPU. Past, Present and Future. Anders Eklund, PhD Virginia Tech Carilion Research Institute andek@vtc.vt.
Medical Image Processing on the GPU Past, Present and Future Anders Eklund, PhD Virginia Tech Carilion Research Institute andek@vtc.vt.edu Outline Motivation why do we need GPUs? Past - how was GPU programming
More informationMRI Technical Operations Manual. Final Version 7.0 20.January.2015
MRI Technical Operations Manual Final Version 7.0 20.January.2015 2 Table of Contents 1 Functional Magnetic Resonance Imaging... 3 1.1 MRI Acquisition Procedures... 3 1.2 MRI Local Read Requirement (Baseline
More informationEXPERIMENT NUMBER 5 BASIC OSCILLOSCOPE OPERATIONS
1 EXPERIMENT NUMBER 5 BASIC OSCILLOSCOPE OPERATIONS The oscilloscope is the most versatile and most important tool in this lab and is probably the best tool an electrical engineer uses. This outline guides
More informationBrain Extraction, Registration & EPI Distortion Correction
Brain Extraction, Registration & EPI Distortion Correction What use is Registration? Some common uses of registration: Combining across individuals in group studies: including fmri & diffusion Quantifying
More informationMATRIX TECHNICAL NOTES
200 WOOD AVENUE, MIDDLESEX, NJ 08846 PHONE (732) 469-9510 FAX (732) 469-0418 MATRIX TECHNICAL NOTES MTN-107 TEST SETUP FOR THE MEASUREMENT OF X-MOD, CTB, AND CSO USING A MEAN SQUARE CIRCUIT AS A DETECTOR
More informationTable 11: Pros and Cons of 1.5 T MRI vs. 3.0 T MRI; Safety and Technical Issues, and Clinical Applications
Safety Issue 3.0 T MRI Pro 3.0 T MRI Con Immediate fringe field surrounding magnet A ferromagnetic object inadvertently brought into the scan room will experience a sharp increase in attraction toward
More informationPulsed Fourier Transform NMR The rotating frame of reference. The NMR Experiment. The Rotating Frame of Reference.
Pulsed Fourier Transform NR The rotating frame of reference The NR Eperiment. The Rotating Frame of Reference. When we perform a NR eperiment we disturb the equilibrium state of the sstem and then monitor
More informationHunting Bats. Diagnostic Ultrasound. Ultrasound Real-time modality
Diagnostik Ultrasound Basic physics, image reconstruction and signal processing Per Åke Olofsson Dpt of Biomedical Engineering, Malmö University Hospital, Sweden Ultrasound Real-time modality 17-WEEK FETAL
More informationIn vivo stem cell tracking in the myocardium of small laboratory animals: Feasibility and acquisition strategies on clinical magnetic resonance
In vivo stem cell tracking in the myocardium of small laboratory animals: Feasibility and acquisition strategies on clinical magnetic resonance imaging (MRI) systems Piotr A. Wielopolski Erasmus MC Department
More informationHow To Use A Sound Card With A Subsonic Sound Card
!"## $#!%!"# &"#' ( "#' )*! #+ #,# "##!$ -+./0 1" 1! 2"# # -&1!"#" (2345-&1 #$6.7 -&89$## ' 6! #* #!"#" +" 1##6$ "#+# #-& :1# # $ #$#;1)+#1#+
More informationMRI QA Technologist s Tests
AAPM 55th Annual Meeting MRI QA Technologist s Tests Guang Jia, PhD Associate Professor Department of Physics Louisiana State University Background Outline QC importance Technologist s role QC test tips
More informationTwelve. Figure 12.1: 3D Curved MPR Viewer Window
Twelve The 3D Curved MPR Viewer This Chapter describes how to visualize and reformat a 3D dataset in a Curved MPR plane: Curved Planar Reformation (CPR). The 3D Curved MPR Viewer is a window opened from
More informationREVIEW. Magnetic Resonance: An Introduction to Ultrashort TE (UTE) Imaging
REVIEW Magnetic Resonance: An Introduction to Ultrashort TE (UTE) Imaging Matthew D. Robson, PhD, Peter D. Gatehouse, DPhil, Mark Bydder, PhD, and Graeme M. Bydder, MB, ChB Abstract: The background underpinning
More informationDoppler. Doppler. Doppler shift. Doppler Frequency. Doppler shift. Doppler shift. Chapter 19
Doppler Doppler Chapter 19 A moving train with a trumpet player holding the same tone for a very long time travels from your left to your right. The tone changes relative the motion of you (receiver) and
More informationTHE WIDEST WIDE-BORE IN THE INDUSTRY
THE WIDEST WIDE-BORE IN THE INDUSTRY The Widest Wide Bore in the Industry 74cm Oval Bore Provides a comfortable and spacious environment around the patient WIT Monitor Allows technologist to review and
More informationOne Port Network Analyzer
99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com One Port Network Analyzer 5.4GHz Impendance : 50Ω(75Ωconnectors via adapters) Test
More informationTechnique and Safety of. by Pierluigi Castellone, Electronics Engineer Brain Products General Manager
Technique and Safety of performing EEG/fMRI measurements by Pierluigi Castellone, Electronics Engineer Brain Products General Manager Contents of the presentation Why recording simultaneous EEG and fmri?
More informationThe smart approach to digital MRI
Philips Healthcare is part of Royal Philips Electronics How to reach us: www.philips.com/healthcare healthcare@philips.com Product information: www.philips.com/smartpathtodstream The smart approach to
More informationTHEORY, SIMULATION, AND COMPENSATION OF PHYSIOLOGICAL MOTION ARTIFACTS IN FUNCTIONAL MRI. Douglas C. Noll* and Walter Schneider
THEORY, SIMULATION, AND COMPENSATION OF PHYSIOLOGICAL MOTION ARTIFACTS IN FUNCTIONAL MRI Douglas C. Noll* and Walter Schneider Departments of *Radiology, *Electrical Engineering, and Psychology University
More informationSR2000 FREQUENCY MONITOR
SR2000 FREQUENCY MONITOR THE FFT SEARCH FUNCTION IN DETAILS FFT Search is a signal search using FFT (Fast Fourier Transform) technology. The FFT search function first appeared with the SR2000 Frequency
More informationProton magnetic resonance spectroscopy in the brain: Report of AAPM MR Task Group #9
Proton magnetic resonance spectroscopy in the brain: Report of AAPM MR Task Group #9 Dick J. Drost a) Nuclear Medicine and MRI Department, St. Joseph s Health Centre, London, Ontario N6A 4L6, Canada William
More informationWhat s new in Trendsetting Applications?
What s new in Trendsetting Applications? Leading. With MAGNETOM. Answers for life. What s new in trendsetting applications? Growth with Body MRI FREEZEit 2 Quiet Suite Advanced WARP 1,3 DotGO 1 MyoMaps
More informationIMAGO7, B1 and Local SAR evaluation
Centro di ricercasullebiotecnologie di risonanza magnetica a campo ultra alto www.imago7.eu IMAGO7, the first Italian 7T MR scanner: B1 and Local SAR evaluation Gianluigi Tiberi INRIM, Febbraio 2014 THE
More informationPurchasing a cardiac CT scanner: What the radiologist needs to know
Purchasing a cardiac CT scanner: What the radiologist needs to know Maria Lewis ImPACT St George s Hospital, London maria.lewis@stgeorges.nhs.uk CT scanner development Slice wars 1998 Increased z-coverage
More informationHigh Field MRI: Technology, Applications, Safety, and Limitations. Brief overview of high-field MRI. The promise of high-field MRI
High Field MRI: Technology, Applications, Safety, and Limitations R. Jason Stafford, Ph.D. Department of Imaging Physics The University of Texas M. D. Anderson Cancer Center Houston, TX Brief overview
More informationHow To Grow With An Mri
Growth with Body MRI Body MRI H.-Hartziekenhuis Lier 40 oz/d tussen 8 en 21 uur 3-5 body mri/d Aparte protocols voor leverletsels / pancreas, mrcp rectum, ovarium, cervix / uterus, pelvimetrie anus / fistula
More informationRE: Invitation for Bid (IFB) No. Q14-32 Type of Service: Magnetic Resonance Imaging System, Maintenance Agreement and Mobile MRI Unit. Addendum No.
VIA EMAIL DATE: June 16, 2014 TO: FROM: Prospective Proposers Maureen Crystal Director of Contracts RE: Invitation for Bid (IFB) No. Q14-32 Type of Service: Magnetic Resonance Imaging System, Maintenance
More informationInvestigation of Magnetic Resonance Imaging Effects when Using Bone Conduction Implants
Investigation of Magnetic Resonance Imaging Effects when Using Bone Conduction Implants Master of Science Thesis in Biomedical Engineering, MPBME Karl-Johan Fredén Jansson Department of Signals and Systems
More informationHDMM01 V1.0. Dual-axis Magnetic Sensor Module With I 2 C Interface FEATURES. Signal Path X
Dual-axis Magnetic Sensor Module With I 2 C Interface FEATURES Low power consumption: typically 0.4mA@3V with 50 measurements per second Power up/down function available through I 2 C interface SET/RESET
More informationBrains Unlimited, UHF MRI, 3T, 7T, 9.4T
Brains Unlimited, UHF MRI, 3T, 7T, 9.4T Erik van den Bergh, Siemens Nederland 2e Hans Boter symposium 1 november 2013 siemens.com/answers Komende 40 minuten o De bouw van een geavanceerd scannerlab o 3T
More informationKey features and examples of DLTS software
Key features and examples of DLTS software 1.1 Software basics 1.2 Software examples 1.3 Database 1.4 Plot programs 1.5 Cryo system 2.1.1 Dlts software structure 2.1.2 Preperation measurements 2.1.3 Static
More informationDKE Fiber Tractography Module: User s Guide Version 1 Release Date: July 2015
DKE Fiber Tractography Module: User s Guide Version 1 Release Date: July 2015 Author: G. Russell Glenn, B.S., B.A. Medical Scientist Training Program (MD / PhD) Department of Neurosciences Department of
More informationR&S ZNBT8 Vector Network Analyzer Specifications
ZNBT8_dat-sw_en_3606-9727-22_v0200_cover.indd 1 Data Sheet 02.00 Test & Measurement R&S ZNBT8 Vector Network Analyzer Specifications 20.05.2014 08:39:42 CONTENTS Definitions... 3 Measurement range... 4
More informationFDA Guidelines for Magnetic Resonance Equipment Safety
FDA Guidelines for Magnetic Resonance Equipment Safety Loren A. Zaremba, Ph.D. Center for Devices and Radiological Health Food and Drug Administration Outline I. Introduction II. Static Magnetic Field
More informationNeuroImage. MP2RAGE, a self bias-field corrected sequence for improved segmentation and T 1 -mapping at high field
NeuroImage 49 (2010) 1271 1281 Contents lists available at ScienceDirect NeuroImage journal homepage: www.elsevier.com/locate/ynimg MP2RAGE, a self bias-field corrected sequence for improved segmentation
More informationAPSYN420A/B Specification 1.24. 0.65-20.0 GHz Low Phase Noise Synthesizer
APSYN420A/B Specification 1.24 0.65-20.0 GHz Low Phase Noise Synthesizer 1 Introduction The APSYN420 is a wideband low phase-noise synthesizer operating from 0.65 to 20 GHz. The nominal output power is
More informationHow To Use A High Definition Oscilloscope
PRELIMINARY High Definition Oscilloscopes HDO4000 and HDO6000 Key Features 12-bit ADC resolution, up to 15-bit with enhanced resolution 200 MHz, 350 MHz, 500 MHz, 1 GHz bandwidths Long Memory up to 250
More informationDICOM Viewer 3.0 Instruction for Use
Philips Medical Systems Nederland BV ICAP-PF -1/34- DICOM Viewer 3.0 Instruction for Use KONINKLIJKE PHILIPS ELECTRONICS N.V. 2013 All rights are reserved. Reproduction or transmission in whole or in part,
More informationLecture 14. Point Spread Function (PSF)
Lecture 14 Point Spread Function (PSF), Modulation Transfer Function (MTF), Signal-to-noise Ratio (SNR), Contrast-to-noise Ratio (CNR), and Receiver Operating Curves (ROC) Point Spread Function (PSF) Recollect
More informationSoftware Packages The following data analysis software packages will be showcased:
Analyze This! Practicalities of fmri and Diffusion Data Analysis Data Download Instructions Weekday Educational Course, ISMRM 23 rd Annual Meeting and Exhibition Tuesday 2 nd June 2015, 10:00-12:00, Room
More informationNumerical Parameters Analysis of Boonton 4540 Peak Power Meter
Application Note Numerical Parameters Analysis of Boonton 4540 Peak Power Meter Mazumder Alam Product Marketing Manager, Boonton Electronics Introduction The Boonton 4540 series RF peak power meters consisting
More informationSynthetic Sensing: Proximity / Distance Sensors
Synthetic Sensing: Proximity / Distance Sensors MediaRobotics Lab, February 2010 Proximity detection is dependent on the object of interest. One size does not fit all For non-contact distance measurement,
More informationREVIEW. Magnetic Resonance in Medicine 00:00 00 (2014)
REVIEW Magnetic Resonance in Medicine 00:00 00 (2014) Recommended Implementation of Arterial Spin-Labeled Perfusion MRI for Clinical Applications: A Consensus of the ISMRM Perfusion Study Group and the
More informationAgilent AN 1316 Optimizing Spectrum Analyzer Amplitude Accuracy
Agilent AN 1316 Optimizing Spectrum Analyzer Amplitude Accuracy Application Note RF & Microwave Spectrum Analyzers Table of Contents 3 3 4 4 5 7 8 8 13 13 14 16 16 Introduction Absolute versus relative
More informationMagnetic Resonance Imaging Level 1
MIAP1 Revised July 2015 MEDICAL IMAGING ADVISORY PANEL 1 Course Syllabus Magnetic Resonance Imaging Level 1 Page 1 of 13 MIAP1 MRI Course Syllabus Guide Under Revision 07 July 2015 Please refer to Medical
More informationStandardized MRI Protocol for Brain Tumor Clinical Trials. Benjamin M. Ellingson, Ph.D. Assistant Professor of Radiology at UCLA
Standardized MRI Protocol for Brain Tumor Clinical Trials Benjamin M. Ellingson, Ph.D. Assistant Professor of Radiology at UCLA Standardized MRI Protocol for Therapeutic Studies FDA Meeting in January
More informationEnDat 2.2 Bidirectional Interface for Position Encoders
Technical Information EnDat 2.2 Bidirectional Interface for Position Encoders Digital drive systems and feedback loops with position s for measured value acquisition require fast data transfer with high
More informationAdding Pneumatic Preset Counter. Type 497. Continuously visible preset Integrated pneumatic reset 3 or 5-digit display Convenient button setting
Adding Pneumatic Preset Counter Type 497 Continuously visible preset Integrated pneumatic reset 3 or 5-digit display Convenient button setting VARIABLE PILOT SIGNAL Using two pneumatic preset counters
More informationMagnetic Resonance Imaging
Magnetic Resonance Imaging 31 (2013) 1439 1444 Contents lists available at ScienceDirect Magnetic Resonance Imaging journal homepage: www.mrijournal.com Technical notes Evaluation of MRI issues for an
More informationIntelliSpace PACS 4.4. Image Enabled EMR Workflow and Enterprise Overview. Learning Objectives
IntelliSpace PACS 4.4 Image Enabled EMR Workflow and Enterprise Overview Learning Objectives Use the Cerner EMR to view images and reports via IntelliSpace PACS: Image Launch Workflow (SUBI Image Viewer)
More informationR&S FS-K7 FM Measurement Demodulator for R&S FSx Software Manual
R&S FS-K7 FM Measurement Demodulator for R&S FSx Software Manual Software Manual Test and Measurement 1141.1821.42 07 The Software Manual R&S FS-K7 describes the following Options: R&S FS-K7 2014 Rohde
More informationSuper-Resolution Reconstruction in MRI: Better Images Faster?
Super-Resolution Reconstruction in MRI: Better Images Faster? Esben Plenge 1,, Dirk H. J. Poot 1, Monique Bernsen 2, Gyula Kotek 2, Gavin Houston 2, Piotr Wielopolski 2, Louise van der Weerd 3, Wiro J.
More informationAccurate Multislice Gradient Echo T 1 Measurement in the Presence of Non-ideal RF Pulse Shape and RF Field Nonuniformity
Accurate Multislice Gradient Echo T 1 Measurement in the Presence of Non-ideal RF Pulse Shape and RF Field Nonuniformity Geoffrey J.M. Parker,* Gareth J. Barker, and Paul S. Tofts Magnetic Resonance in
More informationSupplement to the Operating Instructions for SIMOREG DC-MASTER Series 6RA70. for Software Release 3.2. Version 13 Order no.
s Supplement to the Operating Instructions for SIOREG DC-ASTER Series 6RA7 Version 3 Order no. 6RX7-AD76 for Software Release 3. C983-A756-A4--768 8. Converter software version: As this document went to
More informationPiston Ring. Problem:
Problem: A cast-iron piston ring has a mean diameter of 81 mm, a radial height of h 6 mm, and a thickness b 4 mm. The ring is assembled using an expansion tool which separates the split ends a distance
More informationANALYZER BASICS WHAT IS AN FFT SPECTRUM ANALYZER? 2-1
WHAT IS AN FFT SPECTRUM ANALYZER? ANALYZER BASICS The SR760 FFT Spectrum Analyzer takes a time varying input signal, like you would see on an oscilloscope trace, and computes its frequency spectrum. Fourier's
More informationPropagation Channel Emulator ECP_V3
Navigation simulators Propagation Channel Emulator ECP_V3 1 Product Description The ECP (Propagation Channel Emulator V3) synthesizes the principal phenomena of propagation occurring on RF signal links
More informationDecoding an Accelerometer Specification. What Sensor Manufacturer s Don t Tell You! David Lally VP Engineering PCB Piezotronics, Inc.
Decoding an Accelerometer Specification Sheet What Sensor Manufacturer s Don t Tell You! David Lally VP Engineering PCB Piezotronics, Inc. IMAC-XXVII February 2008 1 Overview Specification Sheet Provides
More informationU1602A Handheld Oscilloscopes, 20 MHz
Products & Services Technical Support Buy Industries About Agilent United States Home >... > Oscilloscopes > U1600A Series handheld oscilloscopes (2 models) > U1602A Handheld Oscilloscopes, 20 MHz Product
More informationMRI QA Technologist s Tests
AAPM 55th Annual Meeting MRI QA Technologist s Tests Guang Jia, PhD, DABR Associate Professor Department of Physics, Louisiana State University Department of Radiology, The Ohio State University Outline
More information