1 GE 3.0T 3.0T WRIST Invivo 8CH Wrist Coil Sequence Ax T2 Cor PD Cor PDFS Cor T1 Cor PD (Small FOV) FOV (mm) Matrix 384x x x x x192 Phase Direction RL RL RL RL RL # of Slices TR/TE (msec) 3000/ / /30 800/ /42 Echo Train (ETL/TF) WFS (BW) Parallel Imaging No No No No No Options TRF,FAST,FR NPW,TRF,FAST,F R NPW,TRF,FAST,F R NPW,TRF,FAST,F R NPW,FAST Sequence Type FRFSE-XL FRFSE-XL FRFSE-XL FRFSE-XL FSE-XL Fat Sat No No Yes No No NEX Scan Time 3:18 4:41 5:00 4:18 5:40 Abbreviations ETL/TF: Echo Train Length or Turbo Factor, the number of k-space lines after an excitation pulse FOV: Field of View GRE: Gradient Echo NEX: Number of Signal Averages or Number of Excitations NPW: No Phase Wrap, conventional oversampling method to prevent image fold-over PD: Proton Density, weighting for short TE, long TR spin-echo scans SAR: Specific Absorption Rate; tissue heating measure limited by the FDA SNR: Signal to Noise Ratio, measure of image quality WFS: Water-Fat Shift (see over), a measure of receiver bandwidth (BW)

2 AX T2

3 COR PD

4 COR PD FS

5 COR T1

6 COR PD Sml FOV

7 GE Healthcare Pulse Sequence Guide SE Pulse Sequence Characteristics 90-degree RF pulse followed by a 180-degree refocusing pulse. Utility Produces T1, PD and T2 weighted images. Differences in contrast are determined by TR/TE. Suggestions 1.5T 3.0T Consider reducing the flip angle for improved contrast (T2 MEMP). Reduce flip angle to 70 (increased contrast, reduced SAR). FSE-XL 90-degree RF pulse followed by multiple "trains" of refocusing 180-degree pulses. Increased blurring compared to SE. Produces T1, PD and T2 weighted images. Differences in contrast are determined by TR/TE. Due to larger B0, consider reduced ETL (reduced blurring) and increased RBW (faster sampling and reduced echo spacing). FRFSE-XL GRE/SPGR FLAIR T1 FLAIR 90-degree RF pulse followed by mutiple "trains" of revocusing 180-degree pulses. A -90- degree pulse is applied at the end of the Echo train to increase T2 weighting. Reduced flip angle for the itinal RF pulse. Gradient reversal is used to refocus the echo. 180-degree inversion pulse applied prior to a conventional FSE based sequence. A T1 (time to invert) determines signal suppression. Same pulse sequence as FLAIR, but the T1 time is based on the desired contrast. Produces T1, PD and T2 weighted images. Differences in contrast are determined by TR/TE. Due to the -90-degree pulse, an increased T2 weighting will be seen as compared to FSE-SL. Reduce TR vs. FSE-XL, T2: <2800 ETL, T1: 3-4, PD: T2:16-24 Produces T1, PD and T2*weighted images. GRE-Reverses gradient polarity. Differences in contrast are determined by TR/TE SPGR - Continuous phase shifting of the RF and flip angle. This sequence is more susceptible to pulse to spoil residual transverse metal inhomogenaity. magnetization. Reduction in signal from fluids that corresponds to T1 time (time to invert). T1 FLAIR is designed to scan the same number of slices as SE, but in an equivalent or shorter scan time. Compared to SE, better CNR and SNR ratios. Reduce TR vs. FSE-XL, T2: <3500 ETL, T1: 2-3, PD:6-8, T2:12-16 Increased susceptibility and flow artifacts. Increase frequency matrix to reduce this effect. Reduce flip angle compared to 1.5T for increased contrast. T2 FLAIR CartiGram (T2 Mapping) TRICKS COSMIC Same pulse sequence as FLAIR, but the T1 time is based on the desired contrast. CartiGram(T2 Mapping) is used to noninvasively detect changes in the collagen component of the extracellular matrix of cartilage. Time Resolved Imaging of Contrast Kinetics (TRICKS). Coherent Oscillatroy State Acquistion for the Manipulation of Imaging Contrast (COSMIC). Fully balanced coherent imaging sequence, with segmented multi-chop centric acquisition. T2 FLAIR is based on the null point of CSF. TR: 3000, TE: 50, T1: 150, RBW 31kHz TR:4000, TE:40, T1:180, RBW:50kHz This application acquires multiple scans at each slice location;each set of scans has a unique TE resulting in a set of gray scal images that represent different T2 weighting. This angio-based technique allows robust, accelerated imaging of dynamic processes in significantly reduced scan times. High SNR and CNR among bone, muscle, cartilage and fluid. Provides mixed T2/T1 and T2 contrast. TR: 800, 256 (freq) x 256 (phase), RBW:31kHz RTR:1000, 384(freq) x 256(phase), RBW: 62 khz

8 In-homogeneous fat saturation Fat saturation can be challenging in areas that are off-center,irregular in size, or very large Additional Topics of Interest Optimiazation of Fat Sat can be performed in several ways: Placing a shim colume over the area to increase homogeneity, choosing between regular or classic fat sat, or using routine fat sat efficiency techniques. Fat Sat efficiency - User CV 19. This al Magnetic susceptibility Signal drop-off, distroted images Increase frequency matrix, reduce slice thickness and increase reception bandwidth. Use FSE-XL, as Gradient Echo does not use refocusing pulses. TR: TE:34(EF), RBW: khz, 512 (f) x (p), NEX:3-4, ETL: increase as high as possible. Popliteal flow artifact (sagittal & coronal) Chemical Shift Fine Line Artifact Occurs in the phase direction only, with mismapping of the popliteal artery across the image Lines or streak-like artifacts Sawp phase and frequency direction. Phase should run S/I, frequence A/P. Add no phase wrap to eliminate phase wrap (alaising) Ensure voxel size is as low as possible. This can be achieved several ways, including: increased reception bandwidth, decreased frequency matrix. (See example) 223Hz x 256 (f) [2x50(RBW)] x 1000Hz=0.57 pixels 447Hz x 256 (f) [2x100(RBW)] x 1000Hz=0.57pixels User VS 21-Enchanced Fine Line Suppression: Widens the "crushers" to reduce the artifact, a slight increase in TE may occur. General 3.0T Guidelines Imaging at 3.0T offers clear benefits of increased SNR and uniform fat saturation. These changes allow increased spatial resolution, reduced NEX (NSA) and reduced scan times to maximize imaging capability. However, T1 recovery can be up to 30% longer an Pulse Sequence Suggestions 1.5T 3.0T T1 FSE TR: , RBW:15-20kHz, ETL:3-4, ST:4mm, 256 (f) x 192 (p), 2 NEX(NSA) TR: , RBW:25-31 khz, ST:3mm, 384(f) x 256(p), 1 NEX(NSA) PD FSE (Routine or Fat Sat) Fat Sat: Use Fat or Fat Classic, User CV 19 to optimize at various Fat Sat levels T2 FSE TR: , RBW:25-31 khz, ETL:8-10, ST: 4mm, 256(f) x 192 (p), 2 NEX(NSA) TR: , RBW:31-50kHz, ETL:16-24, ST:4mm, 256 (f) x 192(p), 2 NEX(NSA) TR: , RBW:42-50kHz, ETL:6-8, ST:3mm, 284(f) x 256(p), 1 NEX(NSA) TR: , RBW:42-50kHz, ETL:12-16, ST:3mm, 384(f) x 256(p), 1 NEX(NSA)

Musculoskeletal MRI Technical Considerations

Musculoskeletal MRI Technical Considerations Musculoskeletal MRI Technical Considerations Garry E. Gold, M.D. Professor of Radiology, Bioengineering and Orthopaedic Surgery Stanford University Outline Joint Structure Image Contrast Protocols: 3.0T

More information

GE Medical Systems Training in Partnership. Module 8: IQ: Acquisition Time

GE Medical Systems Training in Partnership. Module 8: IQ: Acquisition Time Module 8: IQ: Acquisition Time IQ : Acquisition Time Objectives...Describe types of data acquisition modes....compute acquisition times for 2D and 3D scans. 2D Acquisitions The 2D mode acquires and reconstructs

More information

GE Medical Systems Training in Partnership. Module 12: Spin Echo

GE Medical Systems Training in Partnership. Module 12: Spin Echo Module : Spin Echo Spin Echo Objectives Review the SE PSD. Review the concepts of T, T, and T*. Spin Echo PSD RF Gz Gy 90 80 Gx Spin Echo - SE Spin echo is a standard pulse sequence on Signa MRi/LX and

More information

MRI SEQUENCES. 1 Gradient Echo Sequence

MRI SEQUENCES. 1 Gradient Echo Sequence 5 An MRI sequence is an ordered combination of RF and gradient pulses designed to acquire the data to form the image. In this chapter I will describe the basic gradient echo, spin echo and inversion recovery

More information

5 Factors Affecting the Signal-to-Noise Ratio

5 Factors Affecting the Signal-to-Noise Ratio 5 Factors Affecting the Signal-to-Noise Ratio 29 5 Factors Affecting the Signal-to-Noise Ratio In the preceding chapters we have learned how an MR signal is generated and how the collected signal is processed

More information

Matrix, Gradients & Signals Image formation & k-pace

Matrix, Gradients & Signals Image formation & k-pace Outline 6.1 MR Image Formation, s & Signals Image formation & k-pace Imaging s & Signals, and Amplitude selection encoding encoding Carolyn Kaut Roth, RT (R)(MR)(CT)(M)(CV) FSMRT CEO Imaging Education

More information

2/24/2009. Lecture 4 k-space Sampling Techniques and Applications. Clinical MRI Education Lecture 4 will 7am Tue. 2/24. Filling of k-space

2/24/2009. Lecture 4 k-space Sampling Techniques and Applications. Clinical MRI Education Lecture 4 will 7am Tue. 2/24. Filling of k-space Phase Encoding Steps (res = 4) Clinical MRI Education Lecture 4 will start @ 7am Tue. /4 Thanks for arriving early. Please wait Lecture 4 k-space Sampling Techniques and Applications Chen Lin, PhD Indiana

More information

Optimizing the Use of New Technologies for Philips Healthcare MR Scanners Body MR Imaging

Optimizing the Use of New Technologies for Philips Healthcare MR Scanners Body MR Imaging INSTRUCTIONS AND PATIENT PREPARATION Instructions Position Coil Landmark CONTRAST AGENT PARAMETERS Contrast Agents 20- to 22-gauge IV access Power injected Respiratory bellows ALL BREATH HOLDS in EXPIRATION

More information

Overview. Optimizing MRI Protocols (SNR, CNR, Spatial Accuracy) Image Contrast. Image Quality. Intrinsic (Tissue) Parameters

Overview. Optimizing MRI Protocols (SNR, CNR, Spatial Accuracy) Image Contrast. Image Quality. Intrinsic (Tissue) Parameters Overview Optimizing MRI Protocols (SNR, CNR, Spatial Accuracy) Geoffrey D. Clarke, Ph.D. University of TX Health Science Center San Antonio, TX Parameters Affecting Image Quality Manipulating Image Contrast

More information

Techniques of Fat Suppression

Techniques of Fat Suppression Introduction Techniques of Fat Suppression Ian Cameron, PhD FCCPM MR Physicist, The Ottawa Hospital, 501 Smyth Rd., Ottawa, ON, Canada, K1H 8L6 The Magnetic Resonance (MR) signal used to create MR images

More information

Dynamic Bright Blood Imaging What is it?

Dynamic Bright Blood Imaging What is it? Dynamic Bright Blood Imaging What is it? Amol Pednekar, Ph.D. Philips Healthcare, Houston, TX, USA. 1 Disclosure I have following disclosures related to my presentation Employee: Philips Healthcare I will

More information

The Concept of MRI Physics, from Water to Signal to Image

The Concept of MRI Physics, from Water to Signal to Image The Concept of MRI Physics, from Water to Signal to Image Ali Alhamud, PhD alkk1973@gmail.com Magnetic Resonance Imaging (MRI) Yes we know MRI does not use ionizing radiation and it is good for imaging

More information

MGH Adult Diffusion Data Scanning Protocols

MGH Adult Diffusion Data Scanning Protocols MGH Adult Diffusion Data Scanning Protocols Structural scans SIEMENS MAGNETOM ConnectomA syngo MR D11 \\USER\INVESTIGATORS\Default\AAHScout_64 TA:0:14 PAT:3 Voxel size:1.6 1.6 1.6 mm Rel. SNR:1.00 :fl

More information

Kap 8 Image quality, signal, contrast and noise

Kap 8 Image quality, signal, contrast and noise 4/5/ FYS-KJM 474 contrast SNR MR-teori og medisinsk diagnostikk Kap 8 Image qualit, signal, contrast and noise resolution vailable MRparameters speed Main source of noise in MRI: Noise generated within

More information

Overview. Optimizing MRI Protocols. Image Contrast. Morphology & Physiology. User Selectable Parameters. Tissue Parameters

Overview. Optimizing MRI Protocols. Image Contrast. Morphology & Physiology. User Selectable Parameters. Tissue Parameters Overview Optimizing MRI Protocols Clinical Practice & Compromises Geoffrey D. Clarke, Radiology Department University of Texas Health Science Center at San Antonio Pulse timing parameters for adjusting

More information

SITE IMAGING MANUAL ACRIN 6698

SITE IMAGING MANUAL ACRIN 6698 SITE IMAGING MANUAL ACRIN 6698 Diffusion Weighted MR Imaging Biomarkers for Assessment of Breast Cancer Response to Neoadjuvant Treatment: A sub-study of the I-SPY 2 TRIAL Version: 1.0 Date: May 28, 2012

More information

Etude POPART'MUS MRI Component

Etude POPART'MUS MRI Component TECHNICAL SURVEY Dear Investigators, This document is a Technical Survey which provides the teams of THERALYS and of the Pierre Wertheimer Neurological Hospital of Lyon with an overview of your site s

More information

ACR MRI Accreditation Program: The Technologist s Role

ACR MRI Accreditation Program: The Technologist s Role ACR MRI Accreditation Program: The Technologist s Role Geoffrey D. Clarke, Ph.D. University of Texas Health Science Center at San Antonio Radiological Sciences Division Overview ACR MRI Accreditation Program

More information

How to Learn MRI An Illustrated Workbook

How to Learn MRI An Illustrated Workbook How to Learn MRI An Illustrated Workbook Exercise : Advanced Brain Sequences Teaching Points: Learn about Susceptibility Weighted Imaging and how to produce these images. Learn about Axial Fast Inversion

More information

7/16/2010. Pulse Sequences and Acquisition Techniques for Breast MRI. Objectives. ACR Breast MRI Accreditation Program Launched May 2010

7/16/2010. Pulse Sequences and Acquisition Techniques for Breast MRI. Objectives. ACR Breast MRI Accreditation Program Launched May 2010 Pulse Sequences and Acquisition Techniques for Breast MRI ACR Breast MRI Accreditation Program Launched May 2010 Ron Price Vanderbilt University Medical Center Nashville, TN 37232 Information available:

More information

32-Channel Head Coil Imaging at 3T

32-Channel Head Coil Imaging at 3T 32-Channel Head Coil Imaging at 3T Thomas Benner Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital and Harvard Medical School, Boston, MA, USA

More information

Table 11: Pros and Cons of 1.5 T MRI vs. 3.0 T MRI; Safety and Technical Issues, and Clinical Applications

Table 11: Pros and Cons of 1.5 T MRI vs. 3.0 T MRI; Safety and Technical Issues, and Clinical Applications Safety Issue 3.0 T MRI Pro 3.0 T MRI Con Immediate fringe field surrounding magnet A ferromagnetic object inadvertently brought into the scan room will experience a sharp increase in attraction toward

More information

MRI of the Spine Jennifer Jones Radiology Manager Bristol Nuffield

MRI of the Spine Jennifer Jones Radiology Manager Bristol Nuffield MRI of the Spine Jennifer Jones Radiology Manager Bristol Nuffield COILS Used to improve the diagnostic quality of scan images. Used in conjunction with the main bore of the magnet All scanners have different

More information

MR Angiography: Techniques

MR Angiography: Techniques MR Angiography: Techniques Dharshan Vummidi MRCP, FRCR Department of Radiology University of Michigan Disclosures Author for Expert Ddx: Chest, Amirsys Inc. MRA: Principles & Physics Objectives: Essential

More information

3D IMAGING IN MULTIPLE SCLEROSIS

3D IMAGING IN MULTIPLE SCLEROSIS Fang Yu M.D., Carlos Bazan M.D., Bundhit Tantiwongkosi M.D. 3D IMAGING IN MULTIPLE SCLEROSIS University of Texas Health Science Center San Antonio University Hospital Department of Radiology Introduction

More information

7/22/2011. Breast MRI: Pulse Sequences, Acquisition Protocols, and Analysis. Objectives. Challenges in DCE Breast Imaging

7/22/2011. Breast MRI: Pulse Sequences, Acquisition Protocols, and Analysis. Objectives. Challenges in DCE Breast Imaging Breast MRI: Pulse Sequences, Acquisition Protocols, and Analysis Objectives Ron Price Vanderbilt University Medical Center Nashville, TN 37232 1. Review background of MRI breast cancer imaging 2. Present

More information

Nuclear Magnetic Resonance

Nuclear Magnetic Resonance Nuclear Magnetic Resonance Introduction Atomic magnetism Nuclear magnetic resonance refers to the behaviour of atomic nuclei in the presence of a magnetic field. The first principle required to understand

More information

Cirrus 0.2T. MRI for Everyone. North America, Asia, Europe. contact: kturek@mri-tech.pl

Cirrus 0.2T. MRI for Everyone. North America, Asia, Europe. contact: kturek@mri-tech.pl Cirrus 0.2T MRI for Everyone North America, Asia, Europe contact: kturek@mri-tech.pl MRI-TECH inc. Cirrus MRI system for all your needs: Low costs Low maintenance High quality Open geometry Imaging of

More information

Medical Imaging. MRI Instrumentation, Data Acquisition, Image Reconstruction. Assistant Professor Department of Radiology, NYU School of Medicine

Medical Imaging. MRI Instrumentation, Data Acquisition, Image Reconstruction. Assistant Professor Department of Radiology, NYU School of Medicine G16.4426/EL5823/BE6203 Medical Imaging MRI Instrumentation, Data Acquisition, Image Reconstruction Riccardo Lattanzi, Ph.D. Assistant Professor Department of Radiology, NYU School of Medicine Department

More information

MRI screening questions at the time of the confirmation call

MRI screening questions at the time of the confirmation call MRI Patient Preparation Topics Patient Preparation and Management for MRI Clinical Exams Clarian Health 2009 Laurie Owens BSRT (MR) JACHO Patient Safety Goal MRI patient safety screening prior to the appointment

More information

Patient s renal function

Patient s renal function Gadolinium Bolus Contrast Enhanced MRA Wm. Faulkner, B.S.,R.T.(R)(MR)(CT), FSMRT Largely eliminates flow artifacts seen on TOF or PC sequences Image contrast dependent on differences between T1 of gad

More information

3/30/2013. Disclosure. Advanced Neuro MRI: Imaging Techniques and Protocol Optimization. MRI, 35 year ago. MRI Today. Outlines

3/30/2013. Disclosure. Advanced Neuro MRI: Imaging Techniques and Protocol Optimization. MRI, 35 year ago. MRI Today. Outlines http://www.magnet.fsu.edu Disclosure Advanced Neuro MRI: Imaging Techniques and Protocol Optimization Research funding provided by Siemens Healthcare. Chen Lin, PhD DABR Indiana University School of Medicine

More information

MRI for Paediatric Surgeons

MRI for Paediatric Surgeons MRI for Paediatric Surgeons Starship David Perry Paediatric Radiologist Starship Children s Hospital CHILDREN S HEALTH What determines the brightness of a pixel in MRI? i.e. What determines the strength

More information

NMR for Physical and Biological Scientists Thomas C. Pochapsky and Susan Sondej Pochapsky Table of Contents

NMR for Physical and Biological Scientists Thomas C. Pochapsky and Susan Sondej Pochapsky Table of Contents Preface Symbols and fundamental constants 1. What is spectroscopy? A semiclassical description of spectroscopy Damped harmonics Quantum oscillators The spectroscopic experiment Ensembles and coherence

More information

MRI in the wild. Matt Rosen, Ph.D MGH/A.A. Martinos Center/Harvard University

MRI in the wild. Matt Rosen, Ph.D MGH/A.A. Martinos Center/Harvard University MRI in the wild Matt Rosen, Ph.D MGH/A.A. Martinos Center/Harvard University Novel Methods for Phytosequestration ARPA-E Workshop Chicago, 23 July 2015 Wild MRI? High-field MRI instruments are of limited

More information

RF Coils... They ve Come a Long, Long Way

RF Coils... They ve Come a Long, Long Way GE Healthcare MR Field Notes The sensitivity area relates to the diameter of the coil. By Increasing coil size, the area of sensitivity also increases. But as with most MR princicloser a coil s position

More information

Toshiba Excelart Vantage 1.5T MRI Tech Specs (Technical Specifications)

Toshiba Excelart Vantage 1.5T MRI Tech Specs (Technical Specifications) Toshiba Excelart Vantage 1.5T MRI Tech Specs (Technical Specifications) Excelart Vantage Magnet Configuration: Ultra-short-bore Strength (or W x H): 1.5 T Homogeneity, ppm V-RMS: Dimensions of maximum

More information

REVIEW. Magnetic Resonance: An Introduction to Ultrashort TE (UTE) Imaging

REVIEW. Magnetic Resonance: An Introduction to Ultrashort TE (UTE) Imaging REVIEW Magnetic Resonance: An Introduction to Ultrashort TE (UTE) Imaging Matthew D. Robson, PhD, Peter D. Gatehouse, DPhil, Mark Bydder, PhD, and Graeme M. Bydder, MB, ChB Abstract: The background underpinning

More information

Basic Principles of Magnetic Resonance

Basic Principles of Magnetic Resonance Basic Principles of Magnetic Resonance Contents: Jorge Jovicich jovicich@mit.edu I) Historical Background II) An MR experiment - Overview - Can we scan the subject? - The subject goes into the magnet -

More information

Proton magnetic resonance spectroscopy in the brain: Report of AAPM MR Task Group #9

Proton magnetic resonance spectroscopy in the brain: Report of AAPM MR Task Group #9 Proton magnetic resonance spectroscopy in the brain: Report of AAPM MR Task Group #9 Dick J. Drost a) Nuclear Medicine and MRI Department, St. Joseph s Health Centre, London, Ontario N6A 4L6, Canada William

More information

THE WIDEST WIDE-BORE IN THE INDUSTRY

THE WIDEST WIDE-BORE IN THE INDUSTRY THE WIDEST WIDE-BORE IN THE INDUSTRY The Widest Wide Bore in the Industry 74cm Oval Bore Provides a comfortable and spacious environment around the patient WIT Monitor Allows technologist to review and

More information

In vivo stem cell tracking in the myocardium of small laboratory animals: Feasibility and acquisition strategies on clinical magnetic resonance

In vivo stem cell tracking in the myocardium of small laboratory animals: Feasibility and acquisition strategies on clinical magnetic resonance In vivo stem cell tracking in the myocardium of small laboratory animals: Feasibility and acquisition strategies on clinical magnetic resonance imaging (MRI) systems Piotr A. Wielopolski Erasmus MC Department

More information

ORIGINAL PAPER WATER FAT SEPARATION USING THE SINGLE ACQUISITION SANDWICH TYPE 3-POINT DIXON METHOD TO OPTIMIZE KNEE JOINT SCANS

ORIGINAL PAPER WATER FAT SEPARATION USING THE SINGLE ACQUISITION SANDWICH TYPE 3-POINT DIXON METHOD TO OPTIMIZE KNEE JOINT SCANS Nagoya J. Med. Sci. 63. 41 ~ 49, 2000 ORIGINAL PAPER WATER FAT SEPARATION USING THE SINGLE ACQUISITION SANDWICH TYPE 3-POINT DIXON METHOD TO OPTIMIZE KNEE JOINT SCANS ERIKO SHIBAHARA 1, HIROSHI FUKATSU

More information

A Comparison of Five Methods for Signal Intensity Standardization in MRI

A Comparison of Five Methods for Signal Intensity Standardization in MRI A Comparison of Five Methods for Signal Intensity Standardization in MRI Jan-Philip Bergeest, Florian Jäger Lehrstuhl für Mustererkennung, Friedrich-Alexander-Universität Erlangen-Nürnberg jan.p.bergeest@informatik.stud.uni-erlangen.de

More information

RANZCR MRI CLINICAL IMAGE REVIEW PROGRAM : SELF-AUDIT

RANZCR MRI CLINICAL IMAGE REVIEW PROGRAM : SELF-AUDIT RANZCR MRI CLINICAL IMAGE REVIEW PROGRAM : SELF-AUDIT This program is available to sites with machines that have met the MRI clinical image review requirements by peer review at least once previously.

More information

Technique and Safety of. by Pierluigi Castellone, Electronics Engineer Brain Products General Manager

Technique and Safety of. by Pierluigi Castellone, Electronics Engineer Brain Products General Manager Technique and Safety of performing EEG/fMRI measurements by Pierluigi Castellone, Electronics Engineer Brain Products General Manager Contents of the presentation Why recording simultaneous EEG and fmri?

More information

An Overview of Magnetic Resonance Imaging (MRI) Academic Resource Center

An Overview of Magnetic Resonance Imaging (MRI) Academic Resource Center An Overview of Magnetic Resonance Imaging (MRI) Academic Resource Center Table of Contents What is MRI? General MRI Machine Who is it for? How does it work? Magnetization vector Magnetization gradients

More information

7/28/2009. Outline. MR Angiography (MRA) Techniques and Applications. Vascular Abnormities. Human Vascular System. MR Angiography Techniques

7/28/2009. Outline. MR Angiography (MRA) Techniques and Applications. Vascular Abnormities. Human Vascular System. MR Angiography Techniques Outline MR Angiography (MRA) Techniques and Applications Chen Lin, PhD Indiana University School of Medicine & Clarian Health Partners The background The principle and techniques The challenges and solutions

More information

NEURO MRI PROTOCOLS TABLE OF CONTENTS

NEURO MRI PROTOCOLS TABLE OF CONTENTS TABLE OF CONTENTS NEURO MRI PROTOCOLS BRAIN...2 Brain 1 Screen... 2 Brain 2 Brain Tumor... 2 Brain 3 Brain Infection / Meningitis... 2 Brain 4 Trauma... 3 Brain 5 Hemorrhage... 3 Brain 6 Demyelinating

More information

Breast MRI Quality Control

Breast MRI Quality Control Donna M. Reeve, MS, DABR, DABMP Department of Imaging Physics Educational Objectives Discuss the importance of breast MRI quality control (QC). Provide an overview of the new ACR Breast MRI Accreditation

More information

MRI Artifacts: Mechanism and Control

MRI Artifacts: Mechanism and Control MRI Artifacts: Mechanism and Control Chun Ruan Abstract A wide variety of artifacts is routinely encountered on MR images. This article presents the cause, appearance, diagnostic effect, and available

More information

ParaVision 6. Innovation with Integrity. The Next Generation of MR Acquisition and Processing for Preclinical and Material Research.

ParaVision 6. Innovation with Integrity. The Next Generation of MR Acquisition and Processing for Preclinical and Material Research. ParaVision 6 The Next Generation of MR Acquisition and Processing for Preclinical and Material Research Innovation with Integrity Preclinical MRI A new standard in Preclinical Imaging ParaVision sets a

More information

Magnetic Resonance Imaging Level 1

Magnetic Resonance Imaging Level 1 MIAP1 Revised July 2015 MEDICAL IMAGING ADVISORY PANEL 1 Course Syllabus Magnetic Resonance Imaging Level 1 Page 1 of 13 MIAP1 MRI Course Syllabus Guide Under Revision 07 July 2015 Please refer to Medical

More information

MRI Physics for Radiologists

MRI Physics for Radiologists Alfred L. Horowitz MRI Physics for Radiologists A Visual Approach Second Edition With 94 Illustrations Springer-Verlag New York Berlin Heidelberg London Paris Tokyo Hong Kong Barcelona Budapest Alfred

More information

CME. Body MRI Artifacts in Clinical Practice: A Physicist s and Radiologist s Perspective. Review: MR Physics for Clinicians

CME. Body MRI Artifacts in Clinical Practice: A Physicist s and Radiologist s Perspective. Review: MR Physics for Clinicians CME JOURNAL OF MAGNETIC RESONANCE IMAGING 38:269 287 (2013) Review: MR Physics for Clinicians Body MRI Artifacts in Clinical Practice: A Physicist s and Radiologist s Perspective Martin J. Graves, PhD,

More information

NeuroImage. MP2RAGE, a self bias-field corrected sequence for improved segmentation and T 1 -mapping at high field

NeuroImage. MP2RAGE, a self bias-field corrected sequence for improved segmentation and T 1 -mapping at high field NeuroImage 49 (2010) 1271 1281 Contents lists available at ScienceDirect NeuroImage journal homepage: www.elsevier.com/locate/ynimg MP2RAGE, a self bias-field corrected sequence for improved segmentation

More information

Generation and Detection of NMR Signals

Generation and Detection of NMR Signals Generation and Detection of NMR Signals Hanudatta S. Atreya NMR Research Centre Indian Institute of Science NMR Spectroscopy Spin (I)=1/2h B 0 Energy 0 = B 0 Classical picture (B 0 ) Quantum Mechanical

More information

LONI De-Identification Policy

LONI De-Identification Policy The following defines how different file formats are de-identified with LONI tools. Each metadata attribute of each file can have the following operations performed: Operation keep Remove Replace Description

More information

Clinical applications of MRI in radiation therapy. Jatta Berberat, PhD Kantonsspital Aarau jatta.berberat@ksa.ch

Clinical applications of MRI in radiation therapy. Jatta Berberat, PhD Kantonsspital Aarau jatta.berberat@ksa.ch Clinical applications of MRI in radiation therapy Jatta Berberat, PhD Kantonsspital Aarau jatta.berberat@ksa.ch Background and introduction Magnetic Resonance Imaging Relaxation mechanisms Imaging gradients

More information

MRI of the Liver. Pulse Sequences. Pulse Sequences. Pulse Sequences. Imaging Options. Pulse Sequences

MRI of the Liver. Pulse Sequences. Pulse Sequences. Pulse Sequences. Imaging Options. Pulse Sequences Pulse Sequences MRI of the Liver Wm. Faulkner, B.S.,R.T.(R)(MR)(CT), FSMRT T2-W: Fast (Turbo) Spin Echo T1-W: Spoiled Gradient Echo Diffusion-Weighting Balanced Gradient Echo Pulse Sequences T2-W: Fast

More information

Post operative Spinal Imaging- A multimodality approach

Post operative Spinal Imaging- A multimodality approach Post operative Spinal Imaging- A multimodality approach UKRC June 2014 Dr Sajid Butt Consultant Radiology, RNOH Summary Common Spinal Surgeries Image Optimisation Spinal Instrumentation Clinical Scenarios

More information

Magnetic Resonance Imaging

Magnetic Resonance Imaging Magnetic Resonance Imaging What are the uses of MRI? To begin, not only are there a variety of scanning methodologies available, but there are also a variety of MRI methodologies available which provide

More information

RICE UNIVERSITY. Direct Water and Fat Determination in Two-Point Dixon Imaging. Olen Henry Rambow. Master of Science

RICE UNIVERSITY. Direct Water and Fat Determination in Two-Point Dixon Imaging. Olen Henry Rambow. Master of Science RICE UNIVERSITY Direct Water and Fat Determination in Two-Point Dixon Imaging by Olen Henry Rambow A THESIS SUBMITTED IN PARTIAL FULFILLMENT OF THE REQUIREMENTS FOR THE DEGREE Master of Science APPROVED,

More information

High Field MRI: Technology, Applications, Safety, and Limitations. Brief overview of high-field MRI. The promise of high-field MRI

High Field MRI: Technology, Applications, Safety, and Limitations. Brief overview of high-field MRI. The promise of high-field MRI High Field MRI: Technology, Applications, Safety, and Limitations R. Jason Stafford, Ph.D. Department of Imaging Physics The University of Texas M. D. Anderson Cancer Center Houston, TX Brief overview

More information

Magnetic Resonance Spectroscopy

Magnetic Resonance Spectroscopy Magnetic Resonance Spectroscopy Upcoming 26 March (Seth Smith) Magnetization Transfer, Chemical Exchange, T1-rho 28 March Advanced vascular imaging: arterial spin labeling (ASL), susceptibility weighted

More information

Investigation of Magnetic Resonance Imaging Effects when Using Bone Conduction Implants

Investigation of Magnetic Resonance Imaging Effects when Using Bone Conduction Implants Investigation of Magnetic Resonance Imaging Effects when Using Bone Conduction Implants Master of Science Thesis in Biomedical Engineering, MPBME Karl-Johan Fredén Jansson Department of Signals and Systems

More information

Electronic Supplementary Information

Electronic Supplementary Information Electronic Supplementary Material (ESI) for Physical Chemistry Chemical Physics. This journal is the Owner Societies 2016 Electronic Supplementary Information Achieving High Resolution and Controlling

More information

MEDIMAGE A Multimedia Database Management System for Alzheimer s Disease Patients

MEDIMAGE A Multimedia Database Management System for Alzheimer s Disease Patients MEDIMAGE A Multimedia Database Management System for Alzheimer s Disease Patients Peter L. Stanchev 1, Farshad Fotouhi 2 1 Kettering University, Flint, Michigan, 48504 USA pstanche@kettering.edu http://www.kettering.edu/~pstanche

More information

Basics of MRI. Professor Sir Michael Brady FRS FREng Department of Engineering Science Oxford University. Michaelmas 2004

Basics of MRI. Professor Sir Michael Brady FRS FREng Department of Engineering Science Oxford University. Michaelmas 2004 Basics of MRI Professor Sir Michael Brady FRS FREng Department of Engineering Science Oxford University Michaelmas 2004 Lecture 1: MRI image formation Basic nuclear magnetic resonance NMR NMR spectroscopy

More information

Positive Contrast Visualization of Iron Oxide-Labeled Stem Cells using Inversion-Recovery With ON-Resonant Water Suppression (IRON)

Positive Contrast Visualization of Iron Oxide-Labeled Stem Cells using Inversion-Recovery With ON-Resonant Water Suppression (IRON) Magnetic Resonance in Medicine 58:1072 1077 (2007) Positive Contrast Visualization of Iron Oxide-Labeled Stem Cells using Inversion-Recovery With ON-Resonant Water Suppression (IRON) Matthias Stuber, 1

More information

Approved for Public Release; Distribution Unlimited

Approved for Public Release; Distribution Unlimited AD Award Number: TITLE: 4 Tesla Whole Body MRI MRSI System for Investigation of Neurodegenerative Diseases PRINCIPAL INVESTIGATOR: Michael W. Weiner, M.D. CONTRACTING ORGANIZATION: Northern California

More information

Large External Fixator Tibial Shaft Box Frame. Using pin clamps with outrigger posts.

Large External Fixator Tibial Shaft Box Frame. Using pin clamps with outrigger posts. Large External Fixator Tibial Shaft Box Frame. Using pin clamps with outrigger posts. Technique Guide Part of the Large External Fixation System Large External Fixator Tibial Shaft Box Frame Large External

More information

MRI: Magnetic resonance imaging:

MRI: Magnetic resonance imaging: MRI: Magnetic resonance imaging: Like CT, MRI produces detailed cross sectional images of body regions. However the physical principles of image acquisition are different and very complicated. The following

More information

510(k) Summary. This summary of 510(k) safety and effectiveness is being submitted in accordance with the requirements of 21 CFR 807.

510(k) Summary. This summary of 510(k) safety and effectiveness is being submitted in accordance with the requirements of 21 CFR 807. MAR, 2009 / \MLECH MRI-TECH Sp. z o.o., ul. Zielihska 3, 31-227 Krak6w, Poland MRI-TECH Canada, Inc. 206-3820 Cambie Street Vancouver BC V5Z 2X7 510(k) Summary This summary of 510(k) safety and effectiveness

More information

The Magnetic Resonance Imaging Examination

The Magnetic Resonance Imaging Examination The Magnetic Resonance Imaging Examination The purpose of The American Registry of Radiologic Technologists (ARRT ) Examination in Magnetic Resonance Imaging (MRI) is to assess the knowledge and cognitive

More information

MRI DATA PROCESSING. Compiled by: Nicolas F. Lori and Carlos Ferreira. Introduction

MRI DATA PROCESSING. Compiled by: Nicolas F. Lori and Carlos Ferreira. Introduction MRI DATA PROCESSING Compiled by: Nicolas F. Lori and Carlos Ferreira Introduction Magnetic Resonance Imaging (MRI) is a clinical exam that is safe to the patient. Nevertheless, it s very important to attend

More information

MRI in Clinical Radiation Oncology: Dosimetry and Patient-Specific Plan Verification

MRI in Clinical Radiation Oncology: Dosimetry and Patient-Specific Plan Verification Clinical Radiation Therapy MRI in Clinical Radiation Oncology: Dosimetry and Patient-Specific Plan Verification Niko Papanikolaou, Ph.D. 1 ; Geoffrey D. Clarke, Ph.D. 1 ; Lora T. Watts, Ph.D. 1 ; Thomas

More information

Ingenia 1.5T helps to advance MR angiography at Utrecht

Ingenia 1.5T helps to advance MR angiography at Utrecht Publication for the Philips MRI Community Issue 45 2012/1 Ingenia 1.5T helps to advance MR angiography at Utrecht dstream digital architecture and large FOV simplify and accelerate MRA procedures while

More information

NMR Techniques Applied to Mineral Oil, Water, and Ethanol

NMR Techniques Applied to Mineral Oil, Water, and Ethanol NMR Techniques Applied to Mineral Oil, Water, and Ethanol L. Bianchini and L. Coffey Physics Department, Brandeis University, MA, 02453 (Dated: February 24, 2010) Using a TeachSpin PS1-A pulsed NMR device,

More information

Medium External Fixator Tibial Shaft Box Frame. For small-statured adults and pediatric patients, using outrigger posts.

Medium External Fixator Tibial Shaft Box Frame. For small-statured adults and pediatric patients, using outrigger posts. Medium External Fixator Tibial Shaft Box Frame. For small-statured adults and pediatric patients, using outrigger posts. Technique Guide Part of the Medium External Fixation System MRI Information Synthes

More information

Magnetic Resonance Imaging (MRI) and Electromagnetic Fields (EMF)

Magnetic Resonance Imaging (MRI) and Electromagnetic Fields (EMF) Magnetic Resonance Imaging (MRI) and Electromagnetic Fields (EMF) Georg Frese, Hans Engels Introduction The European Parliament and the Council of the European Union have published a draft directive on

More information

Master s Program in Medical Physics. Physics of Imaging Systems Basic Principles of Magnetic Resonance Imaging V. Prof. Dr.

Master s Program in Medical Physics. Physics of Imaging Systems Basic Principles of Magnetic Resonance Imaging V. Prof. Dr. 1 12/9/2008 Page 1 Master s Program in Medical Physics Physics of Imaging Systems Basic Principles of Magnetic Resonance Imaging V Chair in Faculty of Medicine Mannheim University of Heidelberg Theodor-Kutzer-Ufer

More information

T1-weighted Phase Sensitive Inversion Recovery for Imaging Multiple Sclerosis Lesions in the Cervical Spinal Cord

T1-weighted Phase Sensitive Inversion Recovery for Imaging Multiple Sclerosis Lesions in the Cervical Spinal Cord Clinical Neurology T1-weighted Phase Sensitive Inversion Recovery for Imaging Multiple Sclerosis Lesions in the Cervical Spinal Cord Bart Schraa, MSc., Senior MR Application Specialist Siemens LTD Canada

More information

FDA Guidelines for Magnetic Resonance Equipment Safety

FDA Guidelines for Magnetic Resonance Equipment Safety FDA Guidelines for Magnetic Resonance Equipment Safety Loren A. Zaremba, Ph.D. Center for Devices and Radiological Health Food and Drug Administration Outline I. Introduction II. Static Magnetic Field

More information

THEORY, SIMULATION, AND COMPENSATION OF PHYSIOLOGICAL MOTION ARTIFACTS IN FUNCTIONAL MRI. Douglas C. Noll* and Walter Schneider

THEORY, SIMULATION, AND COMPENSATION OF PHYSIOLOGICAL MOTION ARTIFACTS IN FUNCTIONAL MRI. Douglas C. Noll* and Walter Schneider THEORY, SIMULATION, AND COMPENSATION OF PHYSIOLOGICAL MOTION ARTIFACTS IN FUNCTIONAL MRI Douglas C. Noll* and Walter Schneider Departments of *Radiology, *Electrical Engineering, and Psychology University

More information

Contrast Enhanced MRA How I do it

Contrast Enhanced MRA How I do it Contrast Enhanced MRA How I do it Scott B. Reeder, MD, PhD International Society for Magnetic Resonance in Medicine Sociedad Mexicana de Radiologia e Imagen (SMRI) Mexico City June 4, 2014 Department of

More information

Bile Duct Imaging: New Agents, New Sequences

Bile Duct Imaging: New Agents, New Sequences Bile Duct Imaging: New Agents, New Sequences SCBT/MR March 2010 Scott B. Reeder, MD, PhD Department of Radiology University of Wisconsin Madison, WI Disclosure Advisory boards of Bayer, GE Healthcare UW

More information

Nuclear Magnetic Resonance

Nuclear Magnetic Resonance Nuclear Magnetic Resonance Practical Course M I. Physikalisches Institut Universität zu Köln May 15, 2014 Abstract Nuclear magnetic resonance (NMR) techniques are widely used in physics, chemistry, and

More information

Tetramethylsilane (TMS) Trimethylsilyl d 4. -propionic acid (TMSP) Dioxane. O - Na + Dimethylfura n. Potassium Hydrogen Phthalate. Sodium Maleate CH 3

Tetramethylsilane (TMS) Trimethylsilyl d 4. -propionic acid (TMSP) Dioxane. O - Na + Dimethylfura n. Potassium Hydrogen Phthalate. Sodium Maleate CH 3 Practical Aspects of Quantitative NMR Experiments This discussion presumes that you already have an understanding of the basic theory of NMR. There are a number of issues that should be considered when

More information

Diffusione e perfusione in risonanza magnetica. E. Pagani, M. Filippi

Diffusione e perfusione in risonanza magnetica. E. Pagani, M. Filippi Diffusione e perfusione in risonanza magnetica E. Pagani, M. Filippi DW-MRI DIFFUSION-WEIGHTED MRI Principles Diffusion results from a microspic random motion known as Brownian motion THE RANDOM WALK How

More information

Principles of functional Magnetic Resonance Imaging

Principles of functional Magnetic Resonance Imaging 1 Principles of functional Magnetic Resonance Imaging Martin A. Lindquist Department of Biostatistics; Johns Hopkins University Tor D. Wager Department of Psychology & Neuroscience; University of Colorado

More information

Rapid Combined T 1 and T 2 Mapping Using Gradient Recalled Acquisition in the Steady State

Rapid Combined T 1 and T 2 Mapping Using Gradient Recalled Acquisition in the Steady State Rapid Combined T 1 and T 2 Mapping Using Gradient Recalled Acquisition in the Steady State Sean C.L. Deoni, 1,2 Brian K. Rutt, 1 3 and Terry M. Peters 1 3 * Magnetic Resonance in Medicine 49:515 526 (2003)

More information

Basic Pulse Sequences I

Basic Pulse Sequences I Basic Pulse Sequences I Pascale Legault Département de Biochimie Université de Montréal 1 Outline 1) Introduction to Multidimensional NMR 2) The 2D HSQC Experiment: Limitation of Classical Approaches 3)

More information

MODEL 1211 CURRENT PREAMPLEFIER

MODEL 1211 CURRENT PREAMPLEFIER MODEL 1211 CURRENT PREAMPLEFIER Phone: (607)539-1108 Email: info@dlinstruments.com www.dlinstruments.com The Model 1211 Current Preamplifier was designed to provide all of the features required of a modern

More information

Phantom Test Guidance

Phantom Test Guidance Phantom Test Guidance for the ACR MRI Accreditation Program The American College of Radiology 1891 Preston White Dr Reston, VA 20191-4397 www.acr.org Contents 0.0 INTRODUCTION............................................................................

More information

Update: MRI in Multiple sclerosis

Update: MRI in Multiple sclerosis Nyt indenfor MS ved MR Update: MRI in Multiple sclerosis Hartwig Roman Siebner Danish Research Centre for Magnetic Resonance (DRCMR) Copenhagen University Hospital Hvidovre Dansk Radiologisk Selskabs 10.

More information

MR Pulse Sequences: What Every Radiologist Wants to Know but Is Afraid to Ask 1

MR Pulse Sequences: What Every Radiologist Wants to Know but Is Afraid to Ask 1 Note: This copy is for your personal non-commercial use only. To order presentation-ready copies for distribution to your colleagues or clients, contact us at www.rsna.org/rsnarights. EDUCATION EXHIBIT

More information

Single-scan longitudinal relaxation measurements in high-resolution NMR spectroscopy

Single-scan longitudinal relaxation measurements in high-resolution NMR spectroscopy Journal of Magnetic Resonance 164 (2003) 321 328 www.elsevier.com/locate/jmr Single-scan longitudinal relaxation measurements in high-resolution NMR spectroscopy Nikolaus M. Loening, a, * Michael J. Thrippleton,

More information

Technical Note. Frank J. Rybicki, Robert V. Mulkern, Richard L. Robertson, Caroline D. Robson, Taylor Chung, and Jingfei Ma

Technical Note. Frank J. Rybicki, Robert V. Mulkern, Richard L. Robertson, Caroline D. Robson, Taylor Chung, and Jingfei Ma AJNR Am J Neuroradiol :798 80, October 00 Technical Note Fast Three-Point Dixon MR Imaging of the Retrobulbar Space with Low-Resolution Images for Phase Correction: Comparison with Fast Spin-Echo Inversion

More information