COMPREHENSIVE SOLUTIONS AND TECHNICAL WORKFLOWS FOR THE ANALYSIS ON ENVIRONMENTAL POLLUTANTS

Size: px
Start display at page:

Download "COMPREHENSIVE SOLUTIONS AND TECHNICAL WORKFLOWS FOR THE ANALYSIS ON ENVIRONMENTAL POLLUTANTS"

Transcription

1 CMPREHESIVE SLUTIS AD TECHICAL WRKFLWS FR THE AALYSIS EVIRMETAL PLLUTATS Jaume C. Morales MS Product Specialist Agilent Technologies December, 202

2 Introduction Traditional approach ew improvements for new problems Backflush for GCMS GCQTF t-mrm Qual/Quant approach Ion funnel Q-TF technology overview Software for compound identification and quantitation All Ions MS/MS MSC, MetID Mass Profiler Professional Example of QUAL/QUAT. Pharmaceuticals in surface water 2

3 Actual situation on the Enviro and Food analysis

4 Main concern: reduce impact of contaminants to population ff.control Labs Regulatory MRLs control Research Labs Manuf/Distribution Labs Surveillance and risk evaluation, emerging risks studies, (treatment, transport, new contaminants) Contract Labs Warranty regulatory MRLs control

5 Main concern: reduce impact of contaminants to population ff.control Labs Regulatory Target MRLs compounds control Research Labs Manuf/Distribution Labs Unknowns & Surveillance Untarget and risk evaluation, emerging risks studies, Target (treatment, compounds compounds transport, new contaminants) Contract Labs Warranty Target regulatory compounds MRLs control

6 Workflow: Screening Confirmation & Quantification S C Q Sampling GC/MS (MMI) SIM/Scan Final Report for Targets & Unknowns from S Deconvolution C Q If required Extraction GC/QQQ MRM for Targets S C Q LC/QQQ MRM for Targets S C Q If required LC/TF or QTF for Unknowns Identification by querying Exact Mass Data Base Clean-up Molecular Formula Generation C6 H9 P Cl C5 H25 P S Cl C8 H2 P Cl S Q 2 nd injection on MS/MS (QQQ or QTF) C

7 ptimal Workflow for Target analysis Quantification of all regulated compounds in one shot can compromise robustness and sensitivity of the system. Multiresidue methods can show limits depending on chromatography. A previous screening analysis, using identification techniques, allows to have a list of compounds which are present on the sample. Quantification of LY those compounds which were positive on the screening analysis is more robust, sensitive and reliable than trying to afford all regulated compounds at the same time. Screening Confirmation Quantification

8 ptimal Workflow for Target analysis GC/SQ LC/QQQ GC/QQQ LC/TF/QTF Screening Confirmation Cuantification

9 Workflow: Screening Confirmation & Quantification S C Q Sampling GC/MS (MMI) SIM/Scan Final Report for Targets & Unknowns from S Deconvolution C Q If required Extraction GC/QQQ MRM for Targets S C Q LC/QQQ MRM for Targets S C Q If required LC/TF or QTF for Unknowns Identification by querying Exact Mass Data Base Clean-up Molecular Formula Generation C6 H9 P Cl C5 H25 P S Cl C8 H2 P Cl S Q 2 nd injection on MS/MS (QQQ or QTF) C

10 Unknowns Analysis w TF systems TF TF Full Scan HR spectra acquisition x0 +ESI Scan (.89 min) Frag=50.0V 962_D_direkt C5 H S S CH H 0.8 HC HC CH Tiapride 0.8 ppm Counts (%) vs. Mass-to-Charge (m/z) QTF QTF Full Scan HR spectra acquisition HR MS/MS spectra acquisition : x0 +ESI Scan (.89 min) Frag=50.0V 962_D_direkt C5 H S Counts (%) vs. Mass-to-Charge (m/z) Tiapride 0.8 ppm

11 Unknowns Analysis w TF systems Scoring based on Monoisotopic mass (Diff in ppm) Isotopic Distribution (Diff in %) Isotope spacing (Diff in ppm) Analysis with LC/MS TF/QTF of Unknown compounds wants to iedentify these compounds through : Exact mass Isotopic distribution MS/MS spectrum (QTF) n top of that, Full Scan acquisition allows for retrospective analysis.

12 Workflow: Screening Confirmation & Quantification S C Q Sampling GC/MS (MMI) SIM/Scan Final Report for Targets & Unknowns from S Deconvolution C This has been traditional WRKFLW. Q If required Extraction GC/QQQ MRM for Targets AGILET S C Q LC/QQQ MRM for Targets Is introducing new IMPRVEMETS S C Q If required Clean-up LC/TF or QTF for Unknowns Hardware, Software & Tools Identification by querying Exact Mass Data Base to make it more reliable, easy, robust and sensitive Molecular Formula Generation C6 H9 P Cl C5 H25 P S Cl C8 H2 P Cl S Q 2 nd injection on MS/MS (QQQ or QTF) C

13 Workflow: Screening Confirmation & Quantification S C Q Sampling GC/MS (MMI) SIM/Scan Final Report for Targets & Unknowns from S Deconvolution C (+backflush) Q If required Extraction GC/QQQ MRM for Targets S C Q LC/QQQ MRM for Targets S C Q (+backflush) If required LC/TF or QTF for Unknowns Identification by querying Exact Mass Data Base Clean-up Molecular Formula Generation C6 H9 P Cl C5 H25 P S Cl C8 H2 P Cl S Q 2 nd injection on MS/MS (QQQ or QTF) C

14 Microflow Technology Backflush Configurations Constant Pressure with Post-column Backflush EPC Inlet 0 m HP-5ms UI Purged Ultimate Union MS/MS Flexibility to add GC detectors and scalable for shorter runtime! Constant Flow with Mid-column Backflush EPC Inlet 5 m HP-5ms UI Purged Ultimate Union 5 m HP-5ms UI Provides optimal performance and shortest cycle time!. MS/MS

15 Extract Analysis nce set, backflush timing will work for ALL high boilers. - heaviest compounds elute later It took additional min and column to 20 o C to remove these high boilers. Run stopped at 42 min and back flushed at 280 o C for 7 min Blank run after back flushing Column is clean min

16 Workflow: Screening Confirmation & Quantification S C Q Sampling GC/MS (MMI) SIM/Scan Final Report for Targets & Unknowns from S Deconvolution C (+backflush) Q If required Extraction GC/QQQ MRM for Targets S C Q LC/QQQ MRM for Targets S C Q (+backflush) If required Clean-up LC/TF or QTF for Unknowns GCMS? Identification by querying Exact Mass Data Base Molecular Formula Generation C6 H9 P Cl C5 H25 P S Cl C8 H2 P Cl S Q 2 nd injection on MS/MS (QQQ or QTF) C

17 Workflow: Screening Confirmation & Quantification S C Q Sampling GC/MS (MMI) SIM/Scan Final Report for Targets & Unknowns from S Deconvolution C (+backflush) Q If required Extraction GC/QQQ MRM for Targets S C Q LC/QQQ MRM for Targets S C Q (+backflush) If required LC/QTF or GC/QTF for Unknowns Identification by querying Exact Mass Data Base Clean-up GC/QTF Molecular Formula Generation C6 H9 P Cl C5 H25 P S Cl C8 H2 P Cl S Q 2 nd injection on MS/MS (QQQ or QTF) C

18 7200 GC-QTF A new analytical tool to solve complex analytical problems GC/Q-TF for Target, on-target and Unknowns: High Resolution, Accurate Mass and Fast Acquisition Rates MS and MS/MS

19 What is it? 7200 GC/Q-TF = Triple Quadrupole MS + = Quadrupole Time of Flight MS Time of Flight MS

20 The merging of two platforms Ion Mirror 7000 GC/MS QQQ based 6500 LC/MS Q-TF based Quad Mass Filter (Q) Ion Source Transfer optics Collision Cell Ion Pulser Ion Detector Turbo b Turbo a Turbo 2 Turbo

21 ew... Yet Totally Proven 4GHz ADC electronics enable a high sampling rate (2 Gbit/s) which improves the resolution, mass accuracy, and sensitivity for low-abundance samples. Dual gain amplifiers simultaneously process detector signals through both lowgain and high gain channels, extending the dynamic range to 0 5. Hot, quartz monolithic quadrupole analyzer and collision cell identical to the 7000 Quadrupole MS/MS ew Removable Ion Source includes repeller, ion volume, extraction lens and dual filaments Dual-stage ion mirror improves second-order time focusing for high mass resolution. Proprietary IVAR flight tube sealed in a vacuum-insulated shell eliminates thermal mass drift due to temperature changes to maintain excellent mass accuracy, 24/7. Added length improves mass resolution. Analog-to-digital (ADC) Detector: Unlike time-to-digital (TDC) detectors which record single ion events, ADC detection records multiple ion events, allowing very accurate mass assignments over a wide mass range and dynamic range of concentrations. ew Internal Reference Mass can be delivered to the source at a low and high concentration Two 00L/s t urbos pump the focusing optics and flight tube Split-flow turbo differentially pumps the ion source and quadrupole analyzer compartments Hexapole collision cell accelerates ion through the cell to enable faster generation of high-quality MS/MS spectra without cross-talk

22 Key Features of the Internal Reference Mass for routine 2ppm mass accuracy even in heavy matrix 2. Removable Ion Source for quick source cleaning, filament replacement and EI/CI swapping without breaking vacuum. Q-TF MS/MS: Chemical noise reduction. Selectivity. Structural information Method development 4. Software tools formula calculator

23 x TIC スキャンICA0.D GC/MS and LC/MS data analysis Differential analysis with Mass Profiler Professional CE-MS, LC/MS Sample prep Advanced workflow by MPP Detection Data Analysis Chtromatogram Mass Spectrum Component Extraction Create the component list Differential analysis using statistic method Feature extraction by MassHunter or AMDIS GC/MS カウント 対 測 定 時 間 (min) Sample prep MassHunter, MSD ChemStation Detection You can utilize the result of MPP in further data analysis in MassHunter and MSD ChemStation. Mass Profiler Professional 2

24 Agilent Multi-omics Workflow Separate & Detect Feature Finding Alignment & Statistics Identify Pathways Mass Profiler (MP) GC-QTF GC/MSD GC-QQQ MassHunter Qual Find by Chromatogram Deconvolution Mass Profiler Professional (MPP) ID Browser Pathway Architect LC-TF/QTF LC-QQQ MassHunter Qual MFE, Find by Formula, Find by Ion 24

25 Pathway Directed Experiment Creation Propose new experiments based on pathway analysis Re-examine acquired untargeted metabolomics data based on pathway analysis Design new experiments (metabolite, protein or genes) based on pathway results interpretation Build custom metabolite database Custom microarray or GS design PCDL earray Targeted MS/MS Spectrum Mill 25

26 Coffee extract has a much more complex matrix although LLE

27 EIC of 2-Formyl thiophene in Coffee extract at different extraction window

28 MS/MS Chemical oise Reduction (EI) When R and Accurate Are ot Enough (pg F in PFTBA Background) MS m/z : S/ MS/MS 272:222 26: S/ Matrix ions Analyte ions with minimal matrix ions Analyte ions

29 Summary of MS/MS Experiments Accurate mass measurement of molecular ion and fragments C 6 H 7 C 0 H 4 C 4 H 6 C 5 H 6 C 5 H 7 C 6 H 8 C 6 H 6 C 7 H 8 C 9 H 4 C 9 H C 0 H 5 C 4 H 5 09 C 6 H 7 22 C 7 H 8 6 C 9 H 4 48 C 0 H 4 MS 8 C 5 H 7 08 C 6 H 6 80 C 5 H 6 94 C 6 H 8 MS/MS 78 C 5 H 4 55 C H 5 5 C 4 H 5 4 C H 5 66 C 4 H 4 C 9 H

30 Summary of MS/MS Experiments Calculate possible empirical formulas C 6 H 7 C 0 H 4 C 4 H 6 C 5 H 6 C 5 H 7 C 6 H 8 C 6 H 6 C 7 H 8 C 9 H 4 C 9 H C 0 H 5 C 4 H 5 09 C 6 H 7 22 C 7 H 8 6 C 9 H 4 48 C 0 H 4 MS 8 C 5 H 7 08 C 6 H 6 80 C 5 H 6 94 C 6 H 8 MS/MS 78 C 5 H 4 55 C H 5 5 C 4 H 5 4 C H 5 66 C 4 H 4 C 9 H

31 Summary of MS/MS Experiments MS/MS on fragments + accurate mass to find empirical formulas C 6 H 7 C 0 H 4 H C 4 H 6 C 5 H 6 C 5 H 7 C 6 H 8 C 6 H 6 C 7 H 8 C 9 H 4 C 9 H C 0 H 5 C 4 H 5 09 C 6 H 7 22 C 7 H 8 6 C 9 H 4 48 C 0 H 4 MS 80 C 5 H 6 C 5 H 8 CH MS/MS 78 C 5 H 4 H 2 5 C 4 H 5 CH C 9 H

32 Summary of MS/MS Experiments MS/MS on other fragments C 6 H 7 C 0 H 4 C 4 H 6 C 5 H 6 C 5 H 7 C 6 H 8 C 6 H 6 C 7 H 8 C 9 H 4 C 9 H C 0 H 5 C 4 H 5 09 C 6 H 7 22 C 7 H 8 6 C 9 H 4 48 C 0 H 4 MS 8 C 5 H 7 08 C 6 H 6 80 C 5 H 6 94 C 6 H 8 MS/MS 78 C 5 H 4 55 C H 5 5 C 4 H 5 4 C H 5 66 C 4 H 4 C 9 H

33 Formula Calculator: formulas consistent with accurate mass and formula of parent molecule C 5 H 2 2 PS m/z =

34 MassHunter Tools for GC/Q-TF verlaid chromatograms for each deconvoluted compound found Compound mass spectrum with mass caliper tool displaying m/z difference between two ion fragments Molecular and fragment formula calculation results based on accurate mass of the ion

35 Workflow: Screening Confirmation & Quantification S C Q Sampling GC/MS (MMI) SIM/Scan Final Report for Targets & Unknowns from S Deconvolution C (+backflush) Q If required Extraction GC/QQQ MRM for Targets S C Q LC/QQQ MRM for Targets S C Q (+backflush) If required LC/QTF or GC/QTF for Unknowns Identification by querying Exact Mass Data Base Clean-up Molecular Formula Generation C6 H9 P Cl C5 H25 P S Cl C8 H2 P Cl S Q 2 nd injection on MS/MS (QQQ or QTF) C

36 Triggered MRM SCREEIG, QUATIFICATI & CFIRMATI 6

37 Triggered MRM (tmrm) Data Dependent : ~ Scan Specificity with MRM Speed and Sensitivity monitoring MRM per compound triggers up to 8 confirmation MRM of each of the detected compounds Quantification & Confirmation with MRM speed and sensitivity Secondary MRM Transitions are Triggered Threshold Very useful for massive quantification and confirmation with Triple Quadrupole Página 7

38 tmrm Product Ion Spectrum x x > 76 4 > 9 4 > 05 4 > 7 4 > x x x x > 2 x0 4 > x0 4 > 47 x0 4 > x tmrm Product Ion Spectrum

39 tmrm Library Searching Tebufenpyrad Standard 50 ppb Library match score: x x x Cpd : Tebufenpyrad: +ESI MRM:6 ( min, 5 Scans) Frag=65.0V CID@28.0 ( Cpd : Tebufenpyrad: +ESI MRM:6 ( min, 5 Scans) Frag=65.0V CID@28.0 ( Tebufenpyrad C8H24Cl + MRM CAS_Library.mslibrary.xml Counts vs. Mass-to-Charge (m/z)

40 Pesticide Analysis LC/MS QQQ tmrm Pesticide Application Kit 200 Series LC and 6400 Series QQQ LC/MS 40

41 Workflow: Screening Confirmation & Quantification S C Q Sampling GC/MS (MMI) SIM/Scan Final Report for Targets & Unknowns from S Deconvolution C (+backflush) Q If required Extraction GC/QQQ MRM for Targets S C Q LC/QQQ MRM for Targets S C Q (+backflush) If required LC/QTF or GC/QTF for Unknowns Identification by querying Exact Mass Data Base Clean-up Molecular Formula Generation C6 H9 P Cl C5 H25 P S Cl C8 H2 P Cl S Q 2 nd injection on MS/MS (QQQ or QTF) C

42 QUAL/QUA Solutions ew strategy for High Sensitive QTF Instruments Quant Analysis Qualitative Analysis

43 QUAL/QUA Solutions : Agilent 6550 Q-TF with ifunnel Technologies Longer Invar flight tube (resolution + stable mass accuracy) ew- Dual Agilent JetStream orthogonal spray (robust and stable mass calibration) ew- ifunnel (0X sensitivity gain) ew- Ion Beam Compression and Shaping (resolution + sensitivity) Hexapole axial focusing collision cell (faster MS/MS spectra) ew embedded processor (50 spectra/sec) 4 GHz digitizer + ADC detector (resolution, mass accuracy, dynamic range) 4

44 ifunnel Technology Revolutionizes Ion Sampling More efficient ionization Thermal confinement of ESI ion plume Efficient desolvation to create gas phase ions Creates an ion rich zone Heat Sink with Forced Air Cooling Increased ion sampling 6 capillary inlets Samples 2x more ion rich gas from the source Captures the majority of the gas from the source region Greater ion transfer Removes the gas but captures the ions Helps to remove source generated noise Extends turbo pump life ebulizer Heated Sheath Gas Thermal Gradient Focusing Region MS Inlet High Pressure Funnel Low Pressure Funnel 44 44

45 But having just a sensitive QTF is not enough Data process with a SMART Software is key for Qual and Quant workflow 45

46 MassHunter 64 Integrated Software Tools Confidence

47 MassHunter 64 Harness the Power of 64-bit Improved performance for the most complex data sets: Windows 7 64-bit and native 64-bit applications can utilize up to 92 GB of RAM When a native 64-bit program such as MassHunter Qual runs on Windows 7, it can use all the remaining memory! 2 GB 6 GB (shipping Workstation) Windows 7 Pro Up to 24 GB optional --MassHunter Qual --MassHunter Quant =

48 What MassHunter enables for Users? Identify MRE Compounds with Greater Confidence Unique

49 Find by Formula Ion Information 5 x Cpd 4: Tramadol: +ESI EIC( ; ; Ion chromatogram drawn from information Spectra extracted from integrated peak Counts vs. Acquisition Time (min) Compound information from formula or Database Spectral performance calculated

50 All Ions MS/MS AIM for confidence in identification EW! Retrospective Analysis 50

51 MassHunter 64 Identify with Confidence Accurate Mass LC/MS Application Kits Untargeted Screening with TF or QTF 5

52 All Ions MS/MS is enabled on all high-res instruments 6200 Series TF Instruments 6500 Series QTF Instruments 6550 Series ifunnel Q-TF Ion Source Region Collision Cell 52

53 ALL Ions MSMS Workflow Qual EW Find by Formula Algorithm for All ions Use PCDL Lib as source of fragments Acquisition.d data file FindbyFormula on MS low channel Find EICs for fragments on MS high channel Targets m/z, ion species PCDL Targets fragment ions Export modified CEF file for Quant method building Quant requirement : Ability to convert new CEF file in Quant method and Quantitate on All Ions data file. PCDL Requirement : PCDL library content for pesticide available. Extract Align EICs of fragments with parent EIC Qualify and confirm fragments Correlate qualified fragments with target Export 5

54 All Ions MSMS Results verview

55 Import and build Qual/Quant Method from Qual MH Quant MH Qual Compound results + Scan ( min, 5 scans) Tomato 0ppb-r00.d x (M+H) (M+H) (M+H) (M+H)+ (M+H) Mass-to-Charge (m/z) Reference pattern library.cef file Adduct pattern Quant method - Accurate mass EICs for quantifier and qualifier - Relative responses - Retention times 55

56 Quant Method after import of All Ions MS/MS results from Qual Collision energies Product ion information Relative response ratios Uncertainty values updated following point system rules 56

57 Quant Batch at a Glance 57

58 Pharmaceuticals in surface water Direct injection of water samples using high resolution mass spectrometry utilizing the new 6550 Series Agilent QTF ASMS Vancouver, May 202

59 Content Direct Analysis of pharmaceutical in water Method Setup Quantitative Performance Qualitative Performance Summary ASMS Vancouver, May 202

60 Instrumental Setup Agilent 290 UHPLC System including high performance auto sampler and column compartment Up to 200 bar pressure Low dead volume for maximum turn around time Agilent 6550 ifunnel- QTF system ew ifunnel sample introduction for maximum sensitivity resolution for best matrix discrimination and compound identification 4.5 orders in spectral linearity for best quantitative performance ASMS Vancouver, May 202

61 QTF Parameters Mass Spectrometer MS Screening Method: MS Mode:.5 scans/sec, Mass Range: m/z Auto-MS/MS method (data-dependent): MS/MS: 5 scans/sec, Mass Range: m/z for MS 5 scans/sec, Mass Range: m/z for MS2 Precursors per cycle: 0, Threshold 500 counts Active Exclusion after spectra for 0.08 minutes The collision energy (CE) varied proportionally to the precursor m/z value at a slope of 6 ev/00 m/z and an offset of 4 ev. Method : Long Gradient 0.4 ml/min ebulizer: 27 psig Drying gas: 8 L C Sheath gas: L C ozzle: 500 V VCap: 500 V Fragmentor: 20 V Method 2: Short Gradient 0.8 ml/min ebulizer: 5 psig Drying gas: 9 L C Sheath gas: L C ozzle: 500 V VCap: 500 V Fragmentor: 20 V 6 ASMS 202 Vancouver, May 202

62 Import and build Qual/Quant Method from Qual MH Quant MH Qual Compound results + Scan ( min, 5 scans) Tomato 0ppb-r00.d x (M+H) (M+H) (M+H) (M+H)+ (M+H) Mass-to-Charge (m/z) Reference pattern library.cef file Adduct pattern Quant method - Accurate mass EICs for quantifier and qualifier - Relative responses - Retention times ASMS Vancouver, May 202

63 Find by Formula to evaluate compounds, adducts and isotopes, here Diazepam as an example +-0ppm extraction window 0.27 ppm mass error Resolution ASMS 202 Vancouver, May 202

64 Quantitative Performance MS Scan Propranolol x Cpd 7: Propranolol: +ESI EIC( , 277.9) Scan Frag=225.0 oise (RMS) = ; SR (.55min) = MRL 00 ppt.55 x0 4 4 Cpd 7: Propranolol: +ESI EIC( , 277.9) Scan Frag=225.0 oise (RMS) = ; SR (.5min) = ppt Counts vs. Acquisition Time (min) Counts vs. Acquisition Time (min) x0 2 0 Cpd 7: Propranolol: +ESI EIC( , 277.9) Scan Frag=225.0 oise (RMS) = 65.06; SR (.50min) = 5.0 LD 2 ppt Counts vs. Acquisition Time (min) Propranolol - 5 Levels, 5 Levels Used, 0 Points, 0 Points Used, 0 QCs x0 6 y = * x R^2 = Type:Linear, rigin:include, Weight:/x Concentration (ng/ml) 64 ASMS 202 Vancouver, May 202

65 Quantitative Performance MS Scan Ketoprofen x Cpd 6: Ketoprofen: +ESI EIC(255.06, ) Scan Frag=225.0V oise (RMS) = 54.75; SR (4.224min) = 24. MRL 00 ppt x Cpd 6: <Ketoprofen>: +ESI EIC(255.06, ) Scan Frag=225. oise (RMS) = ; SR (4.2min) = ppt Counts vs. Acquisition Time (min) Counts vs. Acquisition Time (min) x0 2.5 Cpd 6: Ketoprofen: +ESI EIC(255.06, ) Scan Frag=225.0V oise (RMS) = ; SR (4.225min) =.5 LD 0 ppt Responses Counts vs. Acquisition Time (min) 65 ASMS 202 Vancouver, May 202

66 Direct injection 00µL surface water spike Results Table Compound ame LD LQ Atenolol Sotalol Metronidazole Ronidazole Sulfadiazine Trimethoprim Sulfamerazine Sulfadimidine Phenazone Pentoxifylline Metoprolol Furazolidone Dapson Sulfamethoxazole Carbamazepine 0, epoxide Phenacetin Bisoprolol Propranolol Carbamazepine Betaxolol n,n Diethyl methylbenzamide (DEET) Bezafibrate Crotamitron Diazepam Fenofibrate.5 2. All Values in ng/l (ppt) Based on DI 2645 calculation using SQS 200, a visual basic add on for Excel Courtesy of Dr. Joachim Kleiner ( All values not more than 5% of the 00 ng/l MRL typical for water analysis ASMS 202 Vancouver, May 202

67 Qual/Quan Results MS-Scan 00 ng/l 50 ng/l 67 ASMS 202 Vancouver, May 202

68 Qual/Quan Results data-dependent MSMS 50 ng/l 68 ASMS 202 Vancouver, May 202

69 Quantitative Performance MS-Scan vs. data dependent MSMS mode Responses MS-Scan Responses 69 ASMS 202 Vancouver, May 202

70 Compound at a glance utlier ASMS Vancouver, May 202

71 Harness the full power of AM MS/MS MS/MS Structural Correlation (MSC) TF MS Generate Formula MS/MS Q-TF MS/MS Correlate Structure Confirm structures Unknown analysis Correlate observed AM MS/MS fragments into proposed structure Using novel systematic bond breaking approach, based on work from Alastair Hill, RCM 2005, 9, -8) The fewer bonds need to be broken, the higher the probability that a proposed fragment will show in the MS/MS spectrum. Breaking double bonds gets assigned a higher penalty than breaking a single bond Same scientific approach as WATERS Mass Fragment Much faster than MassFragment Unique: Can do parallel processing of hundreds of structures! Availability of MassHunter MSC Will ship with MassHunter B as a Tool on Supplemental Disk for FREE! Page 7

72 MassHunter MS/MS Structural Correlation (MSC) USE CASE : Confirm proposed structures Provides highest confidence in confirmation of proposed structures in minutes instead of hours USE CASE : Assigns fragment ions to substructures of a proposed parent structure Metabolite ID Metabolomics Applied Markets Screening Page 72

73 MassHunter MSC USE CASE Confirm proposed structure via accurate mass MS/MS MFG score based on accurate mass of each MS/MS fragment ion and its neutral loss from precursor Total score very high (97.) due to high individual scores and explanation of all high intensity fragment ions. All fragment ions exhibit very high scores (few bond breakages), but multiple candidate isomeric structures are possible, e.g. 4 for MSC calculates molecular formulas (MFG) based on precursor and fragment ions (unique!). The correct formula has a lower precursor score, because only two isotopes were put in and the abundance could not be accurately determined by measuring the printout! MSC calculates all possible subformulas for each fragment ion with mass deviation in mda Showing individual substructures with penalties for Beta Jan 20 Release Mid 20 Page 7

74 MassHunter MS/MS Structural Correlation (MSC) USE CASE 2: Aid true unknown analysis Help identify true unknown compounds STEP : Generate as few as possible molecular formulas from unknown compounds using MS and MS/MS STEP 2: Retrieve all possible structures for the high scoring formulas STEP : Run MS/MS Structural Correlation in batch mode on all formulas => unique to MassHunter MSC STEP 4: Review structures from high scoring structures! Page 74

75 MassHunter MSC USE CASE 2 Correlate total unknown versus large compound set Generate Molecular Formula Generation 94% of Fragment ions explained Retrieved 588 structures and ran MS/MS structural correlation on those. RESULTS in 40 SECDS! Correct structure in rd position

76 MetID software Looking for metabolites of my compounds Structure Pool, created by either: rd party Metabolite prediction Software Data base search / look-up Self-drawn (e.g. with ACD/Labs ChemSketch) F F F m/z 597 S F F F m/z 584 S F F F m/z 570 S MS/MS m/z Measured MS/MS spectrum of metabolite F F F - CH 2 S m/z 6 F F F + 2 m/z 568, major S F F F S m/z 554, major F F F F F F - CH 2 S m/z 625, major + 2 S m/z 64 - CH 2 S F F F Parent, [M+H] + m/z 69 F F F m/z 4, major + 2 F F F F F F - CH 2 m/z 540 S S m/z 655, 2 in rat species 2 4 CH H 5 6 H H CH H CH 2 20 H 22 2 H CH 27 Assigned structure to metabolite

77 Metabolite Structure Elucidation Fragment Assignment Control Sample MS MS/MS m/z Fragmentation 2 4 CH H 6 H H CH H CH 2 20 H 22 2 H CH 27 Metabolite Sample MS Fragmentation MS/MS m/z m/z m/z Manual or software guided solution for fragment assignment with identification of metabolism reaction by detection of chemical shifts H 2 4 CH H 6 H H CH H CH 2 20 H 22 2 H CH 27

78 x Product Ion (99. sec) ( > **) G ppm C) C 0 H D) C H E) C 8 H A) C 9 H F) C 5 H G) C 6 H E ppm A A D -4. ppm ppm C -.08 ppm B) C 2 H F H) C 7 H Azaspirone decane dione C-chainButyl piperazine Pyrimidine (P) (ADD) (BP) ppm ppm Abundance vs. Mass-to-Charge (m/z) QTF MS/MS spectrum of Buspirone. Measured accurate masses of the fragments are annotated in red and calculated relative mass accuracies are annotated in blue.

79 4 x Product Ion (5.5 min) ( > **) G ppm C) C 0 H D) C H E) C 8 H F) C 5 H G) C 6 H E ppm 92.8 C D ppm ppm F -.67ppm ppm Abundance vs. Mass-to-Charge (m/z) Azaspirone decane dione C-chainButyl piperazine Pyrimidine (P) (ADD) (BP) MS/MS spectrum of the monohydroxy metabolite of buspirone. The mass shifts of the fragments (green) in comparison to the MS/MS spectrum of buspirone and the comparable fragments (red) indicate the hydroxylation at the ADD Group (calculated relative mass accuracies are annotated in blue).

80 AALYZERS & KITS Analyzer is a factory-configured GC or GC/MS system configured, tuned and tested for the application prior to delivery to the customer s laboratory. An Application Kit contains the methods, consumables, databases, and standards needed to quickly implement a select GC, GC/MS or LC/MS application at the customer s laboratory. 80

81 Application Kits for Target Screenning 8

82 Application Kits for Untarget Screening 82

83 Agilent Portfolio Atomic Spectroscopy ew!! Flame AA MP AES ICP MS ew!! Graphite C. AA ICP ES ICP MS QQQ

84 Agilent Expertos en Aplicaciones! Más de 70 ingenieros especializados

85 CLEARLY BETTER MS SLUTIS Questions? Mass Spectrometry Technology Products Solutions EW EW EW

Simultaneous qualitative and quantitative analysis using the Agilent 6540 Accurate-Mass Q-TOF

Simultaneous qualitative and quantitative analysis using the Agilent 6540 Accurate-Mass Q-TOF Simultaneous qualitative and quantitative analysis using the Agilent 654 Accurate-Mass Q-TOF Technical Overview Authors Pat Perkins Anabel Fandino Lester Taylor Agilent Technologies, Inc. Santa Clara,

More information

Agilent LCMS products and the application strategies in veterinary drug analysis

Agilent LCMS products and the application strategies in veterinary drug analysis Agilent LCMS products and the application strategies in veterinary drug analysis Experience A New Level of Confidence Ma Xin 马 鑫 LCMS Application Engineer Internal Sales Training - The new 6495 QQQ LC/MS

More information

MassHunter for Agilent GC/MS & GC/MS/MS

MassHunter for Agilent GC/MS & GC/MS/MS MassHunter for Agilent GC/MS & GC/MS/MS Next Generation Data Analysis Software Presented by : Terry Harper GC/MS Product Specialist 1 Outline of Topics Topic 1: Introduction to MassHunter Topic 2: Data

More information

Accurate Mass Screening Workflows for the Analysis of Novel Psychoactive Substances

Accurate Mass Screening Workflows for the Analysis of Novel Psychoactive Substances Accurate Mass Screening Workflows for the Analysis of Novel Psychoactive Substances TripleTOF 5600 + LC/MS/MS System with MasterView Software Adrian M. Taylor AB Sciex Concord, Ontario (Canada) Overview

More information

Outline of MassHunter Software Session

Outline of MassHunter Software Session Outline of MassHunter Software Session 1. Overview MassHunter Software Programs 2. From ChemStation to MassHunter (Optional) 3. MassHunter Qual and Quant (?) 4. MassHunter for LC/MS Demo Find by Methods:

More information

Overview. Triple quadrupole (MS/MS) systems provide in comparison to single quadrupole (MS) systems: Introduction

Overview. Triple quadrupole (MS/MS) systems provide in comparison to single quadrupole (MS) systems: Introduction Advantages of Using Triple Quadrupole over Single Quadrupole Mass Spectrometry to Quantify and Identify the Presence of Pesticides in Water and Soil Samples André Schreiber AB SCIEX Concord, Ontario (Canada)

More information

Metabolomics Software Tools. Xiuxia Du, Paul Benton, Stephen Barnes

Metabolomics Software Tools. Xiuxia Du, Paul Benton, Stephen Barnes Metabolomics Software Tools Xiuxia Du, Paul Benton, Stephen Barnes Outline 2 Introduction Software Tools for LC-MS metabolomics Software Tools for GC-MS metabolomics Software Tools for Statistical Analysis

More information

Agilent 6000 Series LC/MS Solutions CONFIDENCE IN QUANTITATIVE AND QUALITATIVE ANALYSIS

Agilent 6000 Series LC/MS Solutions CONFIDENCE IN QUANTITATIVE AND QUALITATIVE ANALYSIS Agilent 6000 Series LC/MS Solutions CONFIDENCE IN QUANTITATIVE AND QUALITATIVE ANALYSIS AGILENT 6000 SERIES LC/MS SOLUTIONS UNRIVALED ACHIEVEMENT AT EVERY LEVEL The Agilent 6000 Series of LC/MS instruments

More information

Pesticide Analysis by Mass Spectrometry

Pesticide Analysis by Mass Spectrometry Pesticide Analysis by Mass Spectrometry Purpose: The purpose of this assignment is to introduce concepts of mass spectrometry (MS) as they pertain to the qualitative and quantitative analysis of organochlorine

More information

DRUG METABOLISM. Drug discovery & development solutions FOR DRUG METABOLISM

DRUG METABOLISM. Drug discovery & development solutions FOR DRUG METABOLISM DRUG METABLISM Drug discovery & development solutions FR DRUG METABLISM Fast and efficient metabolite identification is critical in today s drug discovery pipeline. The goal is to achieve rapid structural

More information

amazon SL Innovation with Integrity Setting New Standards in Performance, Simplicity and Value Ion Trap MS

amazon SL Innovation with Integrity Setting New Standards in Performance, Simplicity and Value Ion Trap MS amazon SL Setting New Standards in Performance, Simplicity and Value Innovation with Integrity Ion Trap Best-In-Class Ion Trap Mass Spectrometer for Routine Analysis The amazon SL entry-level system is

More information

MultiQuant Software 2.0 for Targeted Protein / Peptide Quantification

MultiQuant Software 2.0 for Targeted Protein / Peptide Quantification MultiQuant Software 2.0 for Targeted Protein / Peptide Quantification Gold Standard for Quantitative Data Processing Because of the sensitivity, selectivity, speed and throughput at which MRM assays can

More information

Using NIST Search with Agilent MassHunter Qualitative Analysis Software James Little, Eastman Chemical Company Sept 20, 2012.

Using NIST Search with Agilent MassHunter Qualitative Analysis Software James Little, Eastman Chemical Company Sept 20, 2012. Using NIST Search with Agilent MassHunter Qualitative Analysis Software James Little, Eastman Chemical Company Sept 20, 2012 Introduction Screen captures in this document were taken from MassHunter B.05.00

More information

API 3200 LC/MS/MS SYSTEM. Performance, productivity and value combined

API 3200 LC/MS/MS SYSTEM. Performance, productivity and value combined API 3200 LC/MS/MS SYSTEM Performance, productivity and value combined API 3200 LC/MS/MS SYSTEM Reliability, reproducibility, and confidence in your data. With an unmatched heritage of technological innovation

More information

A Navigation through the Tracefinder Software Structure and Workflow Options. Frans Schoutsen Pesticide Symposium Prague 27 April 2015

A Navigation through the Tracefinder Software Structure and Workflow Options. Frans Schoutsen Pesticide Symposium Prague 27 April 2015 A Navigation through the Tracefinder Software Structure and Workflow Options Frans Schoutsen Pesticide Symposium Prague 27 April 2015 Kings day in The Netherlands 1 Index Introduction Acquisition, Method

More information

Application of Structure-Based LC/MS Database Management for Forensic Analysis

Application of Structure-Based LC/MS Database Management for Forensic Analysis Cozette M. Cuppett and Michael P. Balogh Waters Corporation, Milford, MA USA Antony Williams, Vitaly Lashin and Ilya Troisky Advanced Chemistry Development, Toronto, ntario, Canada verview Application

More information

Thermo Scientific GC-MS Data Acquisition Instructions for Cerno Bioscience MassWorks Software

Thermo Scientific GC-MS Data Acquisition Instructions for Cerno Bioscience MassWorks Software Thermo Scientific GC-MS Data Acquisition Instructions for Cerno Bioscience MassWorks Software Mark Belmont and Alexander N. Semyonov, Thermo Fisher Scientific, Austin, TX, USA Ming Gu, Cerno Bioscience,

More information

Metabolomic Profiling of Accurate Mass LC-MS/MS Data to Identify Unexpected Environmental Pollutants

Metabolomic Profiling of Accurate Mass LC-MS/MS Data to Identify Unexpected Environmental Pollutants Metabolomic Profiling of Accurate Mass LC- Data to Identify Unexpected Environmental Pollutants André Schreiber 1, David Cox 1, Nadia Pace 1, Christopher Borton 2 1 AB SCIEX, Concord, ntario, Canada; 2

More information

Increasing Quality While Maintaining Efficiency in Drug Chemistry with DART-TOF MS Screening

Increasing Quality While Maintaining Efficiency in Drug Chemistry with DART-TOF MS Screening Increasing Quality While Maintaining Efficiency in Drug Chemistry with DART-TOF MS Screening Application Note Forensics Author Erin Shonsey Director of Research Alabama Department of Forensic Science Abstract

More information

Using Natural Products Application Solution with UNIFI for the Identification of Chemical Ingredients of Green Tea Extract

Using Natural Products Application Solution with UNIFI for the Identification of Chemical Ingredients of Green Tea Extract Using Natural Products Application Solution with UNIFI for the Identification of Chemical Ingredients of Green Tea Extract Lirui Qiao, 1 Rob Lewis, 2 Alex Hooper, 2 James Morphet, 2 Xiaojie Tan, 1 Kate

More information

PosterREPRINT AN LC/MS ORTHOGONAL TOF (TIME OF FLIGHT) MASS SPECTROMETER WITH INCREASED TRANSMISSION, RESOLUTION, AND DYNAMIC RANGE OVERVIEW

PosterREPRINT AN LC/MS ORTHOGONAL TOF (TIME OF FLIGHT) MASS SPECTROMETER WITH INCREASED TRANSMISSION, RESOLUTION, AND DYNAMIC RANGE OVERVIEW OVERVIEW Exact mass LC/MS analysis using an orthogonal acceleration time of flight (oa-tof) mass spectrometer is a well-established technique with a broad range of applications. These include elemental

More information

Enhancing GCMS analysis of trace compounds using a new dynamic baseline compensation algorithm to reduce background interference

Enhancing GCMS analysis of trace compounds using a new dynamic baseline compensation algorithm to reduce background interference Enhancing GCMS analysis of trace compounds using a new dynamic baseline compensation algorithm to reduce background interference Abstract The advantages of mass spectrometry (MS) in combination with gas

More information

AGILENT S BIOINFORMATICS ANALYSIS SOFTWARE

AGILENT S BIOINFORMATICS ANALYSIS SOFTWARE ACCELERATING PROGRESS IS IN OUR GENES AGILENT S BIOINFORMATICS ANALYSIS SOFTWARE GENESPRING GENE EXPRESSION (GX) MASS PROFILER PROFESSIONAL (MPP) PATHWAY ARCHITECT (PA) See Deeper. Reach Further. BIOINFORMATICS

More information

INTEGRATED TECHNOLOGY TO SEE THE WHOLE PICTURE. AxION iqt GC/MS/MS

INTEGRATED TECHNOLOGY TO SEE THE WHOLE PICTURE. AxION iqt GC/MS/MS AxION iqt GC/MS/MS INTEGRATED TECHNOLOGY TO SEE THE WHOLE PICTURE IDENTIFY WHAT YOU RE LOOKING FOR (AND EVEN WHAT YOU RE NOT) The GC/MS/MS Solution for the Work You Do The ideal solution for industrial,

More information

How To Build An Amd Quas 3 Ar Mass Spectrometer

How To Build An Amd Quas 3 Ar Mass Spectrometer Classical and special AMD Magnetic Sector mass spectrometers (extracted from power point presentations) High Resolution Mass Spectromter AMD 402/403 S 6 High Resolution Mass Spectrometer AMD 604 S 8 Version

More information

AMD Analysis & Technology AG

AMD Analysis & Technology AG AMD Analysis & Technology AG Application Note 120419 Author: Karl-Heinz Maurer APCI-MS Trace Analysis of volatile organic compounds in ambient air A) Introduction Trace analysis of volatile organic compounds

More information

In-Depth Qualitative Analysis of Complex Proteomic Samples Using High Quality MS/MS at Fast Acquisition Rates

In-Depth Qualitative Analysis of Complex Proteomic Samples Using High Quality MS/MS at Fast Acquisition Rates In-Depth Qualitative Analysis of Complex Proteomic Samples Using High Quality MS/MS at Fast Acquisition Rates Using the Explore Workflow on the AB SCIEX TripleTOF 5600 System A major challenge in proteomics

More information

# LCMS-35 esquire series. Application of LC/APCI Ion Trap Tandem Mass Spectrometry for the Multiresidue Analysis of Pesticides in Water

# LCMS-35 esquire series. Application of LC/APCI Ion Trap Tandem Mass Spectrometry for the Multiresidue Analysis of Pesticides in Water Application Notes # LCMS-35 esquire series Application of LC/APCI Ion Trap Tandem Mass Spectrometry for the Multiresidue Analysis of Pesticides in Water An LC-APCI-MS/MS method using an ion trap system

More information

GENERAL UNKNOWN SCREENING FOR DRUGS IN BIOLOGICAL SAMPLES BY LC/MS Luc Humbert1, Michel Lhermitte 1, Frederic Grisel 2 1

GENERAL UNKNOWN SCREENING FOR DRUGS IN BIOLOGICAL SAMPLES BY LC/MS Luc Humbert1, Michel Lhermitte 1, Frederic Grisel 2 1 GENERAL UNKNOWN SCREENING FOR DRUGS IN BIOLOGICAL SAMPLES BY LC/MS Luc Humbert, Michel Lhermitte, Frederic Grisel Laboratoire de Toxicologie & Génopathologie, CHRU Lille, France Waters Corporation, Guyancourt,

More information

Unique Software Tools to Enable Quick Screening and Identification of Residues and Contaminants in Food Samples using Accurate Mass LC-MS/MS

Unique Software Tools to Enable Quick Screening and Identification of Residues and Contaminants in Food Samples using Accurate Mass LC-MS/MS Unique Software Tools to Enable Quick Screening and Identification of Residues and Contaminants in Food Samples using Accurate Mass LC-MS/MS Using PeakView Software with the XIC Manager to Get the Answers

More information

How To Use Gc-Ms

How To Use Gc-Ms The CHROMacademy Essential Guide Understanding GC-MS Analysis Part 1 Speakers John Hinshaw GC Dept. Dean CHROMacademy Tony Taylor Technical Director Crawford Scientific Moderator M ( g ) e M ( g ) 2e Peter

More information

How To Test For Contamination In Large Volume Water

How To Test For Contamination In Large Volume Water Automated Solid Phase Extraction (SPE) of EPA Method 1694 for Pharmaceuticals and Personal Care Products in Large Volume Water Samples Keywords Application Note ENV0212 This collaboration study was performed

More information

Overview. Introduction. AB SCIEX MPX -2 High Throughput TripleTOF 4600 LC/MS/MS System

Overview. Introduction. AB SCIEX MPX -2 High Throughput TripleTOF 4600 LC/MS/MS System Investigating the use of the AB SCIEX TripleTOF 4600 LC/MS/MS System for High Throughput Screening of Synthetic Cannabinoids/Metabolites in Human Urine AB SCIEX MPX -2 High Throughput TripleTOF 4600 LC/MS/MS

More information

LC-MS/MS for Chromatographers

LC-MS/MS for Chromatographers LC-MS/MS for Chromatographers An introduction to the use of LC-MS/MS, with an emphasis on the analysis of drugs in biological matrices LC-MS/MS for Chromatographers An introduction to the use of LC-MS/MS,

More information

AB SCIEX TOF/TOF 4800 PLUS SYSTEM. Cost effective flexibility for your core needs

AB SCIEX TOF/TOF 4800 PLUS SYSTEM. Cost effective flexibility for your core needs AB SCIEX TOF/TOF 4800 PLUS SYSTEM Cost effective flexibility for your core needs AB SCIEX TOF/TOF 4800 PLUS SYSTEM It s just what you expect from the industry leader. The AB SCIEX 4800 Plus MALDI TOF/TOF

More information

Bruker ToxScreener TM. Innovation with Integrity. A Comprehensive Screening Solution for Forensic Toxicology UHR-TOF MS

Bruker ToxScreener TM. Innovation with Integrity. A Comprehensive Screening Solution for Forensic Toxicology UHR-TOF MS Bruker ToxScreener TM A Comprehensive Screening Solution for Forensic Toxicology Innovation with Integrity UHR-TOF MS ToxScreener - Get the Complete Picture Forensic laboratories are frequently required

More information

SCION SQ Series GC-MS

SCION SQ Series GC-MS SCION SQ Series GC-MS The Gas Chromatographers Detector SCION SQ TM GC-MS The SCION SQ series GC-MS systems combine innovative engineering with detailed cutomer requirements to produce a truly innovative

More information

Mass Frontier 7.0 Quick Start Guide

Mass Frontier 7.0 Quick Start Guide Mass Frontier 7.0 Quick Start Guide The topics in this guide briefly step you through key features of the Mass Frontier application. Editing a Structure Working with Spectral Trees Building a Library Predicting

More information

EZChrom Edition with OpenLAB ECM

EZChrom Edition with OpenLAB ECM OpenLAB CDS Integration REVOLUTIONIZE of Agilent YOUR DESKTOP OpenLAB CDS SEQUENCING WORKFLOW EZChrom Edition with OpenLAB ECM HALOPLEX TARGET Compliance ENRICHMENT with SYSTEM 2 CFR Part What a Difference

More information

Time-of-Flight Mass Spectrometry

Time-of-Flight Mass Spectrometry Time-of-Flight Mass Spectrometry Technical Overview Introduction Time-of-flight mass spectrometry (TOF MS) was developed in the late 1940 s, but until the 1990 s its popularity was limited. Recent improvements

More information

Expectations for GC-MS Lab

Expectations for GC-MS Lab Expectations for GC-MS Lab Since this is the first year for GC-MS to be used in Dr. Lamp s CHEM 322, the lab experiment is somewhat unstructured. As you move through the two weeks, I expect that you will

More information

Increasing the Multiplexing of High Resolution Targeted Peptide Quantification Assays

Increasing the Multiplexing of High Resolution Targeted Peptide Quantification Assays Increasing the Multiplexing of High Resolution Targeted Peptide Quantification Assays Scheduled MRM HR Workflow on the TripleTOF Systems Jenny Albanese, Christie Hunter AB SCIEX, USA Targeted quantitative

More information

Waters Core Chromatography Training (2 Days)

Waters Core Chromatography Training (2 Days) 2015 Page 2 Waters Core Chromatography Training (2 Days) The learning objective of this two day course is to teach the user core chromatography, system and software fundamentals in an outcomes based approach.

More information

Discovery of Pesticide Protomers Using Routine Ion Mobility Screening

Discovery of Pesticide Protomers Using Routine Ion Mobility Screening Michael McCullagh, 1 David Eatough, 1 Vincent Hanot, 2 and Séverine Goscinny 2 1 Waters Corporation, Wilmslow, UK 2 Wetenschappelijk Instituut Volksgezondheid Institut Scientifique de Santé Publique, Brussels,

More information

Background Information

Background Information 1 Gas Chromatography/Mass Spectroscopy (GC/MS/MS) Background Information Instructions for the Operation of the Varian CP-3800 Gas Chromatograph/ Varian Saturn 2200 GC/MS/MS See the Cary Eclipse Software

More information

A Streamlined Workflow for Untargeted Metabolomics

A Streamlined Workflow for Untargeted Metabolomics A Streamlined Workflow for Untargeted Metabolomics Employing XCMS plus, a Simultaneous Data Processing and Metabolite Identification Software Package for Rapid Untargeted Metabolite Screening Baljit K.

More information

Simultaneous Metabolite Identification and Quantitation with UV Data Integration Using LightSight Software Version 2.2

Simultaneous Metabolite Identification and Quantitation with UV Data Integration Using LightSight Software Version 2.2 Technical ote Simultaneous Metabolite Identification and Quantitation with UV Data Integration Using LightSight Software Version 2.2 Alek. Dooley, Carmai Seto, esham Ghobarah, and Elliott B. Jones verview:

More information

Quick and Sensitive Analysis of Multiclass Veterinary Drug Residues in Meat, Plasma, and Milk on a Q Exactive Focus LC-MS System

Quick and Sensitive Analysis of Multiclass Veterinary Drug Residues in Meat, Plasma, and Milk on a Q Exactive Focus LC-MS System Quick and Sensitive Analysis of Multiclass Veterinary Drug Residues in Meat, Plasma, and Milk on a Q Exactive Focus LC-MS System Olaf Scheibner, Maciej Bromirski, Thermo Fisher Scientific, Bremen, Germany

More information

Pesticide residue analysis: New Trends. Michal Godula, Ph.D. EU Marketing Manager Food Safety & Environmental Thermo Fisher Scientific

Pesticide residue analysis: New Trends. Michal Godula, Ph.D. EU Marketing Manager Food Safety & Environmental Thermo Fisher Scientific Pesticide residue analysis: New Trends Michal Godula, Ph.D. EU Marketing Manager Food Safety & Environmental Thermo Fisher Scientific Why pesticide analysis? Extensively used in agriculture to control

More information

The Scheduled MRM Algorithm Enables Intelligent Use of Retention Time During Multiple Reaction Monitoring

The Scheduled MRM Algorithm Enables Intelligent Use of Retention Time During Multiple Reaction Monitoring The Scheduled MRM Algorithm Enables Intelligent Use of Retention Time During Multiple Reaction Monitoring Delivering up to 2500 MRM Transitions per LC Run Christie Hunter 1, Brigitte Simons 2 1 AB SCIEX,

More information

13C NMR Spectroscopy

13C NMR Spectroscopy 13 C NMR Spectroscopy Introduction Nuclear magnetic resonance spectroscopy (NMR) is the most powerful tool available for structural determination. A nucleus with an odd number of protons, an odd number

More information

Setting up a Quantitative Analysis MS ChemStation

Setting up a Quantitative Analysis MS ChemStation Setting up a Quantitative Analysis MS ChemStation Getting Ready 1. Use the tutorial section "Quant Reports" on the MSD Reference Collection CD-ROM that came with your ChemStation software. 2. Know what

More information

MultiQuant Software Version 3.0 for Accurate Quantification of Clinical Research and Forensic Samples

MultiQuant Software Version 3.0 for Accurate Quantification of Clinical Research and Forensic Samples MultiQuant Software Version 3.0 for Accurate Quantification of Clinical Research and Forensic Samples Fast and Efficient Data Review, with Automatic Flagging of Outlier Results Adrian M. Taylor and Michael

More information

Chemistry 321, Experiment 8: Quantitation of caffeine from a beverage using gas chromatography

Chemistry 321, Experiment 8: Quantitation of caffeine from a beverage using gas chromatography Chemistry 321, Experiment 8: Quantitation of caffeine from a beverage using gas chromatography INTRODUCTION The analysis of soft drinks for caffeine was able to be performed using UV-Vis. The complex sample

More information

HRMS in Clinical Research: from Targeted Quantification to Metabolomics

HRMS in Clinical Research: from Targeted Quantification to Metabolomics A sponsored whitepaper. HRMS in Clinical Research: from Targeted Quantification to Metabolomics By: Bertrand Rochat Ph. D., Research Project Leader, Faculté de Biologie et de Médecine of the Centre Hospitalier

More information

Mass Frontier Version 7.0

Mass Frontier Version 7.0 Mass Frontier Version 7.0 User Guide XCALI-97349 Revision A February 2011 2011 Thermo Fisher Scientific Inc. All rights reserved. Mass Frontier, Mass Frontier Server Manager, Fragmentation Library, Spectral

More information

Application Note # LCMS-81 Introducing New Proteomics Acquisiton Strategies with the compact Towards the Universal Proteomics Acquisition Method

Application Note # LCMS-81 Introducing New Proteomics Acquisiton Strategies with the compact Towards the Universal Proteomics Acquisition Method Application Note # LCMS-81 Introducing New Proteomics Acquisiton Strategies with the compact Towards the Universal Proteomics Acquisition Method Introduction During the last decade, the complexity of samples

More information

A High Throughput Automated Sample Preparation and Analysis Workflow for Comprehensive Forensic Toxicology Screening using LC/MS/MS

A High Throughput Automated Sample Preparation and Analysis Workflow for Comprehensive Forensic Toxicology Screening using LC/MS/MS A High Throughput Automated Sample Preparation and Analysis Workflow for Comprehensive Forensic Toxicology Screening using LC/MS/MS AB SCIEX QTRAP 4500 LC/MS/MS System and Gerstel, Inc. MultiPurpose Sampler

More information

Analysis of Liquid Samples on the Agilent GC-MS

Analysis of Liquid Samples on the Agilent GC-MS Analysis of Liquid Samples on the Agilent GC-MS I. Sample Preparation A. Solvent selection. 1. Boiling point. Low boiling solvents (i.e. b.p. < 30 o C) may be problematic. High boiling solvents (b.p. >

More information

Quantitative analysis of anabolic steroids in control samples from food-producing animals using a column-switching LC-HESI-MS/MS assay

Quantitative analysis of anabolic steroids in control samples from food-producing animals using a column-switching LC-HESI-MS/MS assay PO-CON1484E Quantitative analysis of anabolic steroids in control samples from food-producing animals using a column-switching ASMS 014 TP85 David R. Baker 1, John Warrander 1, Neil Loftus 1, Simon Hird

More information

WATERS QUANTITATIVE ANALYSIS solutions

WATERS QUANTITATIVE ANALYSIS solutions More sensitivity. More speed. What more can you ask for in a complete quantitative analysis solution? WATERS QUANTITATIVE ANALYSIS solutions THE CHALLENGE OF QUANTITATIVE ANALYSIS Tandem mass spectrometry,

More information

Strategies for Developing Optimal Synchronous SIM-Scan Acquisition Methods AutoSIM/Scan Setup and Rapid SIM. Technical Overview.

Strategies for Developing Optimal Synchronous SIM-Scan Acquisition Methods AutoSIM/Scan Setup and Rapid SIM. Technical Overview. Strategies for Developing Optimal Synchronous SIM-Scan Acquisition Methods AutoSIM/Scan Setup and Rapid SIM Technical Overview Introduction The 5975A and B series mass selective detectors (MSDs) provide

More information

Improving the Metabolite Identification Process with Efficiency and Speed: LightSight Software for Metabolite Identification

Improving the Metabolite Identification Process with Efficiency and Speed: LightSight Software for Metabolite Identification Improving the Metabolite Identification Process with Efficiency and Speed: LightSight Software for Metabolite Identification Overview LightSight Software for Metabolite Identification is a complete environment

More information

The Use of Micro Flow LC Coupled to MS/MS in Veterinary Drug Residue Analysis

The Use of Micro Flow LC Coupled to MS/MS in Veterinary Drug Residue Analysis The Use of Micro Flow LC Coupled to MS/MS in Veterinary Drug Residue Analysis Stephen Lock AB SCIEX Warrington (UK) Overview A rapid, robust, sensitive and specific LC-MS/MS method has been developed for

More information

Thermo Scientific Prelude SPLC System FPO. Making LC/MS accessible. to clinical research and toxicology labs

Thermo Scientific Prelude SPLC System FPO. Making LC/MS accessible. to clinical research and toxicology labs Thermo Scientific Prelude SPLC System FPO Making LC/MS accessible to clinical research and toxicology labs Specifically designed to make the power of LC/MS accessible Analysis of target compounds in complex

More information

Accelerate your Quantitative LC/MS Workflows with a Fully Integrated UHPLC-QQQ Platform

Accelerate your Quantitative LC/MS Workflows with a Fully Integrated UHPLC-QQQ Platform Accelerate your Quantitative LC/MS Workflows with a Fully Integrated UHPLC-QQQ Platform Remco Swart Pittcon March 8-12, 2015 1 The world leader in serving science Outline Thermo Scientific Vanquish UHPLC

More information

MRMPilot Software: Accelerating MRM Assay Development for Targeted Quantitative Proteomics

MRMPilot Software: Accelerating MRM Assay Development for Targeted Quantitative Proteomics MRMPilot Software: Accelerating MRM Assay Development for Targeted Quantitative Proteomics With Unique QTRAP and TripleTOF 5600 System Technology Targeted peptide quantification is a rapidly growing application

More information

Building Agilent GC/MSD Deconvolution Reporting Libraries for Any Application Technical Overview

Building Agilent GC/MSD Deconvolution Reporting Libraries for Any Application Technical Overview Building Agilent GC/MSD Deconvolution Reporting Libraries for Any Application Technical Overview Authors Xiaofei Ping Agilent Technologies (Shanghai) Co Ltd 412 Yinglun Road, Shanghai, 200131 P.R. China

More information

Analysis of Pesticides in Vegetables Using the Agilent 1260 Infinity Analytical SFC System with Triple Quadrupole MS Detection

Analysis of Pesticides in Vegetables Using the Agilent 1260 Infinity Analytical SFC System with Triple Quadrupole MS Detection Analysis of Pesticides in Vegetables Using the Agilent 1260 Infinity Analytical SFC System with Triple Quadrupole MS Detection Application Note Food Testing & Agriculture Authors Edgar Naegele and Thomas

More information

Agilent Metabolomics Workflow

Agilent Metabolomics Workflow Agilent Metabolomics Workflow Discovery Workflow Guide Prepare for an experiment Find features Import and organize data Create an initial analysis Advanced operations Define the experiment Create method

More information

New drugs of abuse? A case study on Phenazepam & Methoxetamine

New drugs of abuse? A case study on Phenazepam & Methoxetamine New drugs of abuse? A case study on Phenazepam & Methoxetamine Presenter: Nadia Wong Co authors: Dr Yao Yi Ju & Alex Low Xuan Kai Analytical Toxicology Laboratory Clinical & Forensic Toxicology Unit Applied

More information

Micromass LCT User s Guide

Micromass LCT User s Guide Micromass LCT User s Guide 1) Log on to MassLynx with your username & password. 2) After you have logged in, the MassLynx software will automatically run. 3) After MassLynx has come up, open your project

More information

Agilent Enhanced Matrix Removal Lipid LOSE THE LIPIDS, FIND YOUR ANALYTES

Agilent Enhanced Matrix Removal Lipid LOSE THE LIPIDS, FIND YOUR ANALYTES Agilent Enhanced Matrix Removal Lipid LOSE THE LIPIDS, FIND YOUR ANALYTES AGILENT ENHANCED MATRIX REMOVAL LIPID ARE LIPIDS WEIGHING YOUR SAMPLES DOWN? Interference from lipids is a problem for labs measuring

More information

Electrospray Ion Trap Mass Spectrometry. Introduction

Electrospray Ion Trap Mass Spectrometry. Introduction Electrospray Ion Source Electrospray Ion Trap Mass Spectrometry Introduction The key to using MS for solutions is the ability to transfer your analytes into the vacuum of the mass spectrometer as ionic

More information

Appendix 5 Overview of requirements in English

Appendix 5 Overview of requirements in English Appendix 5 Overview of requirements in English This document is a translation of Appendix 4 (Bilag 4) section 2. This translation is meant as a service for the bidder and in case of any differences between

More information

Analysis of the Vitamin B Complex in Infant Formula Samples by LC-MS/MS

Analysis of the Vitamin B Complex in Infant Formula Samples by LC-MS/MS Analysis of the Vitamin B Complex in Infant Formula Samples by LC-MS/MS Stephen Lock 1 and Matthew Noestheden 2 1 AB SCIEX Warrington, Cheshire (UK), 2 AB SCIEX Concord, Ontario (Canada) Overview A rapid,

More information

Thermo Scientific ExactFinder Software

Thermo Scientific ExactFinder Software mass spectrometry Thermo Scientific ExactFinder Software Workflow software for routine targeted and general unknown screening Unifies qualitative and quantitative high-resolution accurate mass workflows

More information

LC-MS/MS Method for the Determination of Docetaxel in Human Serum for Clinical Research

LC-MS/MS Method for the Determination of Docetaxel in Human Serum for Clinical Research LC-MS/MS Method for the Determination of Docetaxel in Human Serum for Clinical Research J. Jones, J. Denbigh, Thermo Fisher Scientific, Runcorn, Cheshire, UK Application Note 20581 Key Words SPE, SOLA,

More information

Thermo Scientific PepFinder Software A New Paradigm for Peptide Mapping

Thermo Scientific PepFinder Software A New Paradigm for Peptide Mapping Thermo Scientific PepFinder Software A New Paradigm for Peptide Mapping For Conclusive Characterization of Biologics Deep Protein Characterization Is Crucial Pharmaceuticals have historically been small

More information

Fast, Reproducible LC-MS/MS Analysis of Dextromethorphan and Dextrorphan

Fast, Reproducible LC-MS/MS Analysis of Dextromethorphan and Dextrorphan Fast, Reproducible LC-MS/MS Analysis of and Kimberly Phipps, Thermo Fisher Scientific, Runcorn, Cheshire, UK Application Note 685 Key Words Accucore C18, dextromethorphan, dextrorphan, SOLA CX Abstract

More information

MarkerView Software 1.2.1 for Metabolomic and Biomarker Profiling Analysis

MarkerView Software 1.2.1 for Metabolomic and Biomarker Profiling Analysis MarkerView Software 1.2.1 for Metabolomic and Biomarker Profiling Analysis Overview MarkerView software is a novel program designed for metabolomics applications and biomarker profiling workflows 1. Using

More information

QGA Quantitative Gas Analyser

QGA Quantitative Gas Analyser QGA Quantitative Gas Analyser A compact bench-top system for real-time gas and vapour analysis Detailed product information / introduction catalysis studies environmental gas analysis fermentation off-gas

More information

AxION edoor. Web-Based, Open-Access Mass Spectrometry Software

AxION edoor. Web-Based, Open-Access Mass Spectrometry Software AxION edoor Web-Based, Open-Access Mass Spectrometry Software 2 AxION edoor is the open-access software solution for today s fast-paced laboratory. It is designed to operate and optimize the management

More information

Application Note # LCMS-62 Walk-Up Ion Trap Mass Spectrometer System in a Multi-User Environment Using Compass OpenAccess Software

Application Note # LCMS-62 Walk-Up Ion Trap Mass Spectrometer System in a Multi-User Environment Using Compass OpenAccess Software Application Note # LCMS-62 Walk-Up Ion Trap Mass Spectrometer System in a Multi-User Environment Using Compass OpenAccess Software Abstract Presented here is a case study of a walk-up liquid chromatography

More information

Method development for analysis of formaldehyde in foodsimulant. melamine-ware by GC-MS and LC-MS/MS. Internal Technical Report

Method development for analysis of formaldehyde in foodsimulant. melamine-ware by GC-MS and LC-MS/MS. Internal Technical Report of melamine-ware by GC-MS and LC-MS/MS Page 1 of 15 Method development for analysis of formaldehyde in foodsimulant extracts of melamine-ware by GC-MS and LC-MS/MS December 2012 Contact Point: Chris Hopley

More information

Alignment and Preprocessing for Data Analysis

Alignment and Preprocessing for Data Analysis Alignment and Preprocessing for Data Analysis Preprocessing tools for chromatography Basics of alignment GC FID (D) data and issues PCA F Ratios GC MS (D) data and issues PCA F Ratios PARAFAC Piecewise

More information

Introduction. What Can an Offline Desktop Processing Tool Provide for a Chemist?

Introduction. What Can an Offline Desktop Processing Tool Provide for a Chemist? Increasing Chemist Productivity in an Open-Access Environment Ryan Sasaki, Graham A. McGibbon, Steve Hayward Featuring ACD/Spectrus Processor and Aldrich Library for ACD/Labs Advanced Chemistry Development,

More information

The First Quantitative Analysis of Alkylated PAH and PASH by GCxGC/MS and its Implications on Weathering Studies

The First Quantitative Analysis of Alkylated PAH and PASH by GCxGC/MS and its Implications on Weathering Studies The First Quantitative Analysis of Alkylated PAH and PASH by GCxGC/MS and its Implications on Weathering Studies INEF Penn State Conference 2013 Albert Robbat, Jr. and Patrick Antle Tufts University, Chemistry

More information

泛 用 蛋 白 質 體 學 之 質 譜 儀 資 料 分 析 平 台 的 建 立 與 應 用 Universal Mass Spectrometry Data Analysis Platform for Quantitative and Qualitative Proteomics

泛 用 蛋 白 質 體 學 之 質 譜 儀 資 料 分 析 平 台 的 建 立 與 應 用 Universal Mass Spectrometry Data Analysis Platform for Quantitative and Qualitative Proteomics 泛 用 蛋 白 質 體 學 之 質 譜 儀 資 料 分 析 平 台 的 建 立 與 應 用 Universal Mass Spectrometry Data Analysis Platform for Quantitative and Qualitative Proteomics 2014 Training Course Wei-Hung Chang ( 張 瑋 宏 ) ABRC, Academia

More information

Analyzing Small Molecules by EI and GC-MS. July 2014

Analyzing Small Molecules by EI and GC-MS. July 2014 Analyzing Small Molecules by EI and GC-MS July 2014 Samples Appropriate for GC-MS Volatile and semi-volatile organic compounds Rule of thumb,

More information

Effects of Intelligent Data Acquisition and Fast Laser Speed on Analysis of Complex Protein Digests

Effects of Intelligent Data Acquisition and Fast Laser Speed on Analysis of Complex Protein Digests Effects of Intelligent Data Acquisition and Fast Laser Speed on Analysis of Complex Protein Digests AB SCIEX TOF/TOF 5800 System with DynamicExit Algorithm and ProteinPilot Software for Robust Protein

More information

Simultaneous Qualitative and Quantitative Data Acquisition for Research of Diabetes Drugs

Simultaneous Qualitative and Quantitative Data Acquisition for Research of Diabetes Drugs Liquid Chromatography Mass Spectrometry SSI-LCMS-068 Simultaneous Qualitative and Quantitative Data Acquisition for Research of Diabetes Drugs LCMS-8050 Summary By utilizing the LCMS-8050 s ultrafast scan

More information

How To Analyze Plasma With An Inductively Coupled Plasma Mass Spectrometer

How To Analyze Plasma With An Inductively Coupled Plasma Mass Spectrometer What is ICP-MS? and more importantly, what can it do? Inductively Coupled Plasma Mass Spectrometry or ICP-MS is an analytical technique used for elemental determinations. The technique was commercially

More information

Supplementary Materials and Methods (Metabolomics analysis)

Supplementary Materials and Methods (Metabolomics analysis) Supplementary Materials and Methods (Metabolomics analysis) Metabolite extraction and mass spectrometry analysis. 12 Vldlr-/- knock out and 12 wild type (WT) retinas were separately frozen at -80 ºC in

More information

Integrated Data Mining Strategy for Effective Metabolomic Data Analysis

Integrated Data Mining Strategy for Effective Metabolomic Data Analysis The First International Symposium on Optimization and Systems Biology (OSB 07) Beijing, China, August 8 10, 2007 Copyright 2007 ORSC & APORC pp. 45 51 Integrated Data Mining Strategy for Effective Metabolomic

More information

Mass Spectrometry. Overview

Mass Spectrometry. Overview Mass Spectrometry Overview Mass Spectrometry is an analytic technique that utilizes the degree of deflection of charged particles by a magnetic field to find the relative masses of molecular ions and fragments.2

More information